You are on page 1of 8

CONTROL SISMICO DE CORTE BASAL EN EDIFICIOS

ESTE ARTICULO SE REFIERE AL ANALISIS DINAMICO DE SUPERPOSICION MODAL


CONFORME CON LA NORMA COVENIN MINDUR 1756-01 EDIFICACIONES SISMORRESISTENTES

NOMBRE EDIFICIO: RAMPA EMERGENCIAS - HOSPITAL BARINAS

DATOS DE ENTRADA:
a = Factor de Importancia = 1.30
Ao = Coeficiente de Aceleracin Horizontal = 0.25 (COVENIN 1756-01, P. 15.)
N = Numero de Plantas del Edificio = 1.00
hn = Altura del Edificio = 4.25 m
W = Peso de la Estructura (Reacciones en las Base en SAP2000) = 1367435 kgf

DIRECCION X:
Tipo = I CONCRETO
Rx = Factor de Reduccin de Respuesta en Direccion X = 5.00 (COVENIN 1756-01, P. 29.)
Ct = Constante en la formula del Periodo Fundamental = 0.07 (COVENIN 1756-01, P. 46.)
T* = Periodo Obtenido en Table 7.1 COVENIN MINDUR 1756-01 = 1.00 sec
Vox = Fuerza de Corte en la Base en Direccion X = 500216 kgf

DIRECCION Y:
Tipo = I CONCRETO
Ry = Factor de Reduccin de Respuesta en Direccion Y = 5.00 (COVENIN 1756-01, P. 29.)
Ct = Constante en la formula del Periodo Fundamental = 0.07 (COVENIN 1756-01, P. 46.)
Voy = Fuerza de Corte en la Base en Direccion Y = 598376 kgf

PROCESAMIENTO DE DATOS:
DIRECCION X:
Tax = Periodo Fundamental de Vibracion en Direccion X = 0.21 sec
Tx = 1.6 Tax = 0.33 sec
Adx = Ordenada Espectral para el Periodo T Fundamental en la Direccion X = 0.14
m1 = 1.00
m2 = 0.76
m = 1.00

V*ox = Fuerza de Corte en la Base en Direccion X = m Adx W = 189,116.26 kgf

DIRECCION Y:
Tay = Periodo Fundamental de Vibracion en Direccion Y = 0.21 sec
Ty = 1.6 Tay = 0.33 sec
Ady = Ordenada Espectral para el Periodo T Fundamental en la Direc = 0.14
m1 = 1.00
m2 = 0.76
m = 1.00
V oy = Fuerza de Corte en la Base en Direccion Y = m Ady W
*
= 189,116.26 kgf

RESULTADOS:
V*ox / Vox = 0.38 Si el ratio es mayor que 1.00 se debe aplicar el valor de este factor en el espectro sismico.
V*oy / Voy = 0.32 Si el ratio es mayor que 1.00 se debe aplicar el valor de este factor en el espectro sismico.

Vox / W = 0.37 > aAo / Rx = 0.07 OK


Voy / W = 0.44 > aAo / Ry = 0.07 OK
CONTROL OF SEISMIC BASE SHEAR IN BUILDINGS
APPLIES TO DYNAMIC ANALYSIS USING MODAL SUPERPOSITION WITH 3 DOF PER STORY LEVEL
THIS VERIFICATION COMPLIES WITH COVENIN MINDUR 1756-01 EDIFICACIONES SISMORRESISTENTES

BUIILDING NAME: 59-STR-505 OFFICES

INPUT DATA: Note: Cells in blue are for user input, in red are program calculated.
a = Importance Factor = 1.00
Ao = Horizontal Acceleration Coefficient = 0.3 (COVENIN 1756-01, P. 15.)
N = Number of stories in building = 1
hn = building height = 6.3 m
W = Weight of structure (from base reactions in SAP2000) = 14,428 kgf

X-DIRECTION:
Tipo = I STEEL
Rx = Response Reduction Factor in X Direction = 6.00 (COVENIN 1756-01, P. 29.)
Ct = Constant in fundamental period formula = 0.08 (COVENIN 1756-01, P. 46.)
T* = Period given in Table 7.1 COVENIN MINDUR 1756-01 = 1 sec
Vox = Base Shear Force in X Direction from analysis = 11,273 kgf

Y-DIRECTION:
Tipo = I STEEL
Ry = Response Reduction Factor in Y Direction = 6.00 (COVENIN 1756-01, P. 29.)
Ct = Constant in fundamental period formula = 0.08 (COVENIN 1756-01, P. 46.)
Voy = Base Shear Force in Y Direction from analysis = 11,765 kgf

DATA PROCESSING:
X-DIRECTION:
Tax = Fundamental period of vibration in X Direction = 0.3181 sec
Tx = 1.6 Tax = 0.5090 sec
Adx = Spectral ordinate for fundamental period T in X Direction = 0.11
m1 = 1.0000
m2 = 0.7659
m = 1
V*ox = Base Shear Force in X Direction = m Adx W = 1,514.94 kgf

Y-DIRECTION:
Tay = Fundamental period of vibration in Y Direction = 0.3181 sec
Ty = 1.6 Tay = 0.5090 sec
Ady = Spectral ordinate for fundamental period T in Y Direction = 0.11
m1 = 1.0000
m2 = 0.7659
m = 1
V*oy = Base Shear Force in Y Direction = m Ady W = 1,514.94 kgf

RESULTS: Si el ratio es mayor que 1.00 se debe aplicar el valor de este factor en el espectro sismico.
V*ox / Vox = 0.1344 If this ratio is greater than 1.00 then apply this factor to the seismic spectra values.
V*oy / Voy = 0.1288 If this ratio is greater than 1.00 then apply this factor to the seismic spectra values.
Si el ratio es mayor que 1.00 se debe aplicar el valor de este factor en el espectro sismico.
Vox / W = 0.7813 > aAo / Rx = 0.0500 OK
Voy / W = 0.8154 > aAo / Ry = 0.0500 OK
CONTROL DE CORTE BASAL ESTRUCTURAS
NOMBRE ESTRUCTURA: Enfriador (E-J15101/202) de 60 PSIG

DATOS DE ENTRADA:
N = Numero total de niveles, donde se han concretado los pesos =
hn = Altura del Edificio =
W = Peso de la Estructura (SAP2000) =
Ct = Constante en la formula del Periodo Fundamental =
T*
= Periodo caracteristico del espectro de diseo =
Vox = Fuerza de Corte en la Base en Direccin X =
Voy = Fuerza de Corte en la Base en Direccin Y =

PROCESAMIENTO DE DATOS:
DIRECCION X y DIRECCION Y:
Tax = Periodo Fundamental de Vibracin =
Tx = 1.6 Tax =
Adx = Ordenada Espectral para el Periodo T Fundamental =
m1 = 1.00
m2 = 0.76
m = 1.00

V*ox = Fuerza de Corte en la Base en ambas direcciones = m Adx W =

RESULTADOS:
V*ox / Vox = 0.93 Si la relacin es mayor que 1.00 se debe aplicar el valor de este factor e
V*oy / Voy = 0.93 Si la relacin es mayor que 1.00 se debe aplicar el valor de este factor e
1.00
3.92 m
112576.21 kgf
0.07
1.20 sec
28381.55 kgf
28238.49 kgf

0.20 sec
0.31 sec
0.2345

26,399.12 kgf

el valor de este factor en el espectro ssmico.


el valor de este factor en el espectro ssmico.
CONTROL DE CORTE BASAL ESTRUCTURAS
NOMBRE ESTRUCTURA: CONTROL DE ACCESO

DATOS DE ENTRADA:
N = Numero total de niveles, donde se han concretado los pesos
hn = Altura del Edificio
W = Peso de la Estructura (SAP2000)
Ct = Constante en la formula del Periodo Fundamental
T* = Periodo caracteristico del espectro de diseo
Vox = Fuerza de Corte en la Base en Direccin X
Voy = Fuerza de Corte en la Base en Direccin Y

PROCESAMIENTO DE DATOS:
DIRECCION X y DIRECCION Y:
Tax = Periodo Fundamental de Vibracin
Tx = 1.6 Tax
Adx = Ordenada Espectral para el Periodo T Fundamental
m1 = 1.00
m2 = 0.97
m = 0.97

V*ox = Fuerza de Corte en la Base en ambas direcciones = m Adx W

RESULTADOS:
V*ox / Vox = 0.13 Si la relacin es mayor que 1.00 se debe aplicar el valor de este factor e
V*oy / Voy = 0.12 Si la relacin es mayor que 1.00 se debe aplicar el valor de este factor e
= 1.00
= 6.30 m
= 14,428.02 kgf
= 0.08
= 1.00 sec
= 11272.63 kgf
= 11764.98 kgf

= 0.32 sec .
= 0.51 sec
= 0.1050

= 1469.49 kgf

aplicar el valor de este factor en el espectro ssmico.


aplicar el valor de este factor en el espectro ssmico.

You might also like