You are on page 1of 2

3/18/2017 pleasecananyoneadviseonwhatloadcombinationshallicalculatethemaxstorydriftformultistorybuldingnotingthati'musingEurocode2008

EhabOnsy 3d
please
DirectorofProjectsatEnforceConsultants

cananyoneadviseonwhatload
combinationshallicalculatethe
maxstorydriftformultistory
buldingnotingthati'musing
Eurocode2008
Like Comment 1 9

EgiSinoimeri1dead+0.3live+1Ex+0.3Ey

1dead+0.3live+1Ey+0.3Ex

1.35dead+1.5live

Like 2d

rachidbentafatHiEGI:Youhavethereferencesofthecombinationof
Newmarkwhichassignsthecoefficient0.3forliveload.Ingeneral,weuse1DEAD+1LIVE

+Ex+0.3Ey...greetings

Like 2d

EgiSinoimeriyes,newmarkcombination
Like 2d

PeterPlaczekNonsense!YoudoNOTcombineloadstogetdrifts.Youareafter
SEISMICdriftsoyouusetheSEISMICloadsalone.Thereare2typesofdrifts:"ultimatelimit

statedrift"and"damagelimitationsstatedrift".Readthecodefordefinition,limitsand

multiplicationfactorsonthedifferentdrifts.

https://www.linkedin.com/groups/2983130/29831306247738965571575808?midToken=AQHuxL_7EYX22w&trk=emlb2_anet_digest_of_digestshero11di 1/2
3/18/2017 pleasecananyoneadviseonwhatloadcombinationshallicalculatethemaxstorydriftformultistorybuldingnotingthati'musingEurocode2008

Like 2 2d

SaumilParikhIfyouareusingetabsthereisaloadcasewhichyoucandefine
withseismiccalledseismicdrift

Like 2d

VictorAguilarVidalNoneedforcombination.useseismicloadalone.
Dependsonyourcodeifyoushoulduseelasticseismicorreducedseismicfordriftcheck.

Like 1 1d

HimenshuPraveenagreewithPeter
Like 4h

KamalTafishyouhavetouseSeismicloadsCombinationsaccordingtothecode
youuse.

Like 4h

EhabOnsythanksallnowI'musingresponsespectrumshallIdependonthe
resultsfordriftfromorusecombination