You are on page 1of 41

Vazamento Zero S

PDF created with pdfFactory trial version www.pdffactory.com


Vazamento Anual S
1 gota/10s SS 95 L

1 gota/5s SSSS 190 L

1 gota/s SSSSSSSSSS 950 L

3 gotas/s SSSSSSSSSSSSSSSS 2.800 L

escorrimento SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS 19.000 L

10 100 1.000 10.000 20.000

PDF created with pdfFactory trial version www.pdffactory.com


Consequncias do Vazamento S
Indstria

S S
S S S

PDF created with pdfFactory trial version www.pdffactory.com


Consequncias do Vazamento S
Construo

S
S
S
S S
S S

PDF created with pdfFactory trial version www.pdffactory.com


Consequncias do Vazamento S
Agricultura

O "
"B I
S
S
S SS

PDF created with pdfFactory trial version www.pdffactory.com


Vazamento Zero S
Disperdcio, custo, segurana, burocracia e recursos so
questes que envolvem todos os setores de uma empresa,
seja de pequeno ou grande porte.

Vazamento em sistemas hidrulicos uma preocupao


comum na maioria das empresas que focam qualidade e
objetivam melhorias no processo produtivo.

A maior parte dos vazamentos est localizada nas


interligaes dos sistemas hidrulicos, onde so aplicados
tubos, mangueiras e conexes.

PDF created with pdfFactory trial version www.pdffactory.com


Vazamento Zero S
Atravs dos produtos e conceitos do Programa Vazamento
Zero da Parker totalmente vivel alcanar eficcia em
estanqueidade do fluido e maior vida til do equipamento.

Produtos: Conexes Seal-Lok, EO2 e EO2-Form


Sistema Parkrimp (mangueiras)

Conceitos: Treinamento de Produto


Orientao de Montagem e Instalao
Facilidade de Manuseio
Menor Possibilidade de Falha
Vedao Macia (Metal-Borracha)
PDF created with pdfFactory trial version www.pdffactory.com
Causas do Vazamento S
O que causam falhas prematuras em
conexes e mangueira ?

Baixa Qualidade do Produto


Padro do fabricante, Mistura fabricantes

Erro de Especificao Menor


Condies de trabalho, Escolha no apropriada

Erro de Montagem
Vida
til
Ferramentas, Dobra, Cravamento, Limpeza

Erro de Instalao
Torque, Braadeira, Toro, Abraso, Curvatura

PDF created with pdfFactory trial version www.pdffactory.com


Consequncias do Vazamento S
n Custo do produto reposto $

n Custo de reposio do leo perdido $

n Custo de manuteno $

n Perda de produtividade $
$
n Poluio do meio ambiente $

n Segurana e risco sade $

n Risco de incndio $ Disperdcio

n Desvalorizao do equipamento $

PDF created with pdfFactory trial version www.pdffactory.com


Objetivos do Vazamento Zero S
n Uso de produtos com
desempenho superior

n Maior vida til

n Maior produtividade Eliminar


n Menor custo de manuteno Disperdcio

n Menos burocracia

n Menor custo global

PDF created with pdfFactory trial version www.pdffactory.com


Produtos No Aplicados S

Vedao Metal / Metal

PDF created with pdfFactory trial version www.pdffactory.com


Conexo JIC 37 - Metal/Metal S

Clique sobre a figura

PDF created with pdfFactory trial version www.pdffactory.com


Produtos do Vazamento Zero S
Conexo Seal-Lok Conexes EO2

Vedao Metal / Borracha

SAE J1453 DIN 2353


ISO 8434-3 ISO 8434-1

PDF created with pdfFactory trial version www.pdffactory.com


Conexo Seal-Lok S
Sistema Parflange Sistema Soldado

PDF created with pdfFactory trial version www.pdffactory.com


Conexo Seal-Lok S
Sistema Soldado

Clique sobre a figura

PDF created with pdfFactory trial version www.pdffactory.com


Conexo Seal-Lok S
Sistema Parflange

PDF created with pdfFactory trial version www.pdffactory.com


Conexo Seal-Lok S
Clique sobre a figura

PDF created with pdfFactory trial version www.pdffactory.com


Conexo EO2 S
Evoluo das Anilhas

D D

1930 1956

DPR EO-2

1980 1993

PDF created with pdfFactory trial version www.pdffactory.com


Comparativo EO e EO2 S
1
Sistema EO DPR / PSR
Porca Porca

Corpo
Anilha de
Corpo

Vedao


Tubo
Tubo

Lbio de Suporte Anilha de


Vedao Metlico Cravamento
1 - Duas bordas cortantes Moldado
2 - Ancoragem traseira absorve vibrao
3 - Efeito mola aumenta a resistncia da anilha

- Vedao metal / metal


- Desgaste do corpo da conexo (dureza maior da anilha)
- Preocupao com aperto correto (orientao do fabricante)
- Pr-montagem + montagem final
- Uso de ferramentas

PDF created with pdfFactory trial version www.pdffactory.com


Conexo EO2 S
Montagem

PDF created with pdfFactory trial version www.pdffactory.com


Conexo EO2 S
Manuteno

Substituir somente o
anel de vedao

PDF created with pdfFactory trial version www.pdffactory.com


Conexo EO2 S

Clique sobre a figura

PDF created with pdfFactory trial version www.pdffactory.com


Conexo EO2-Form S

ISO 8434-4
DIN 3865

PDF created with pdfFactory trial version www.pdffactory.com


Conexo EO2-Form S

Clique sobre a figura

PDF created with pdfFactory trial version www.pdffactory.com


Conexo EO2-Form S

Clique sobre a figura

PDF created with pdfFactory trial version www.pdffactory.com


Vazamento Zero S

PDF created with pdfFactory trial version www.pdffactory.com


Roscas Cnicas S
M BSPT NPTF

DIN 3852-C ISO 7/1 ANSI/


DIN 2999 ASME B 1.20.1

PDF created with pdfFactory trial version www.pdffactory.com


Roscas Paralelas S
BSPP / Mtrica
Anel de cobre Borda Cortante Anel ED

DIN 3852-A ISO 1179-4 (BSPP) ISO 1179-2 (BSPP)


ISO 9974-3 (M) ISO 9974-2 (M)
DIN 3852-B DIN 3852-E

ISO 1179 (BSPP)


ISO 9974 (M)
DIN 3852-X

PDF created with pdfFactory trial version www.pdffactory.com


Roscas Paralelas S
UNF Mtrica BSPP / Mtrica

ISO 11926 ISO 6149 ISO 1179-2 (BSPP)


DIN 3852-F ISO 9974-2 (M)
DIN 3852-E

ISO 11926 ISO 6149 ISO 1179 (BSPP)


ISO 9974 (M)
DIN 3852-X

PDF created with pdfFactory trial version www.pdffactory.com


Roscas Paralelas S
Vedao metal-metal
Borda cortante ou
FM FP
FM Anel de Cobre

FP

t
6

FP
FM FM

FP

Vedao com anel ED Vedao com anel O

PDF created with pdfFactory trial version www.pdffactory.com


Comparativo de Desempenho S
Mtrica DIN 3852-X
bar
3500 Anel O Anel ED Borda Rosca Anel de
Cortante Cnica Cobre
DIN7603
3000
3094

2500 2733 PN X 4
2000

2057

1975
1500 PN X 2,5
1000

983
500 PN 630
0
Tipo Tipo Tipo Tipo Tipo
F E B C A
Conexo para tubo de 10mm com rosca macho M16 x 1.5

PDF created with pdfFactory trial version www.pdffactory.com


Vazamento Zero S
Testes Normas Parmetros
Vazamento NFPA T3.8.3 / DIN 3859 T3 N/He 100 Bar

Ruptura DIN 50104 / DIN 3859 T3 Mnimo 4 X PN

Trao DIN 50145

Impulsao NFPA T3.8.3 / DIN 3859 T3 1 Milho de Ciclos (PN X 1.33)

Vibrao NFPA T3.8.3 / ISO 8434 1 + 9 Milhes de Ciclos


DIN 3859 T3

Temperatura Parker EO 120C PN

Remontagens NFPA T3.8.3 / DIN 3859 T3 10 X

PDF created with pdfFactory trial version www.pdffactory.com


Testes S

Ruptura Vazamento

Dureza

Impulsao Vibrao

PDF created with pdfFactory trial version www.pdffactory.com


Qualidade Parker S
n Lder Mundial em produtos para conduo de fluidos.

n Reconhecimento internacional.

n Inovao tecnolgica.

n Padronizao dos produtos em todas as fbricas Parker em


qualquer parte do mundo.

n Uso de modernos equipamentos de produo.

n Certificao ISO 9001/9002 e QS 9000.

PDF created with pdfFactory trial version www.pdffactory.com


Dicas de Montagem S
Corte e Rebarbamento

PDF created with pdfFactory trial version www.pdffactory.com


Equipamentos S

PDF created with pdfFactory trial version www.pdffactory.com


Equipamentos S

PDF created with pdfFactory trial version www.pdffactory.com


Acessrios S

PDF created with pdfFactory trial version www.pdffactory.com


Dicas de Instalao S
Errado Certo Errado Certo
Errado

Certo

PDF created with pdfFactory trial version www.pdffactory.com


Pense Nisso S
Em geral, mangueiras e conexes
representam menos que 3% do custo total
de um equipamento.

Entretanto, produtos de baixa qualidade ou


erros de especificao, montagem ou instalao
podem causar falhas no equipamento
e gerar perdas financeiras.

Pense nisso antes de escolher


Mangueiras e Conexes.