Work experience
Electra Consultants Electrical Design Engineer 01/2017 - present
KPK
Pakistan Projects: Koto Hydro power Project, 40.8 MW & Machai Hydro power Project, 2.6 MW

Details pertaining to my job duties are as follows;

Detailed design review of Main single line diagram with conformance to the design practicality
and required speci cations.
Design review and nalization of protection & metering design drawings pertaining to the
Generators, Main Transformers, 132 kV Transmission lines, Busbars & Auxiliary systems.
Reviewed and performed detailed design calculations pertaining to the adequate sizing of
station service transformers and standby diesel generators.
Performed detailed design analysis of DC system in accordance with IEEE 485 - 1997 to select
the suitable capacity of the battery system according to the required load demand.
Design review of electrical layout drawings e.g. powerhouse, outdoor switchyard, control room &
switchgear room etc.
Reviewed & performed Electrical cable size calculations as per IEC 60364 and analyzed the
results of Short circuit calculations in accordance with the guidelines speci ed in IEC 60909.
Studied the grounding system design according to IEEE Std 80-2000 and recommended
technical solutions to the EPC Contractor regarding the selection of earthing material, size of
earthing conductor and mesh etc for improved system reliability and personnel safety in the
event of different electrical faults.
Reviewed and performed design calculation of lightning protection system for 132 kV outdoor
switchyard using Rolling Sphere Method asspeci ed in IEC 62305.
Design review of O & M Manuals and As Built Drawings of Machai HPP.
Study the testing & commissioning protocols of Machai HPP in line with the guidelines and
procedures being speci ed in IEC 60545-1976.

Punjab Hydropower Jr. Engineer (Electrical) 10/2013 12/2016


Consultants
Punjab Projects: Marala HPP, 7.64 MW; Pakpattan HPP, 2.82 MW; Chaianwali HPP, 5.36 MW & Deg Outfall
Pakistan HPP, 4.04 MW

Details of my job responsibilities are given as under;


Work experience
Guarantee Test for Horizontal shaft Kaplan Turbine & Generating Unit as per IEC 60041 & 60043
respectively.
Detailed study and monitoring of Electrical & Mechanical parameters during 72 Hour Full Load
Run Test.
Analyzing transient behavior of power plant during Load Rejection Test.
Review SCADA designs for essential modi cations.
Supervised installation and testing of SCADA systems to ensure functionality & simpli ed user
experience.
Preparation of Test Reports for Employer pertaining to the E & M tests carried out at site.
Surveillance of compliance to quality standards & speci cations.
Testing & commissioning of 6.3 kV, Two (2) numbers of hydro generators with rated capacity of
1.41 MW each;
1. Start up and trial operation tests
2. Short Circuit Characteristic test
3. No load Characteristic Test

Grounding test of power plant using earthing test set UNI-T UT 521.

11 kV, 6.3 kV & 0.4 kV cable tests;


1. Megger Test
2. High voltage A.C Test
3. High Voltage D.C Test

Factory acceptance tests of distribution transformers at PEL (Pak Elektron Ltd.) facility;

1. Measurement for Break down voltage of T/F Mineral Oil using Dielectric Tester
2. Measurement of short circuit impedance and load losses.
3. Measurement of voltage ratio and check of phase displacement
4. Measurement of no load losses & current
5. Separate source voltage withstands test / power frequency test.
6. Induced over voltage withstand test.
7. Measurement of winding resistance.

Detailed study and approval of design drawings, speci cations and technical documents.
Design review and approval of interconnection study report including load ow studies, transient
stability analysisand short circuit levels during single phase, phase to phase and 3 phase faults.
Performed voltage drop, ampicity and technical losses calculations for Transmission lines.
Transmission Lines Route survey and visits to interconnected grid stations for data collection.
Design & construction of single circuit & double circuit 11 kV overhead transmission line as per
WAPDA specs.
Design review and approval of Plan & Pro le Diagrams for double circuit & triple circuit overhead
transmission lines.
Design of 11 kV Incoming interconnected panels at Grid End as per WAPDA speci cations
devised in P-44.
Design and selection of surge arrestors for protection of transmission lines against lightning
stokes.
Detailed design review of setting calculations for Overcurrent protection (IDMT, De nite &
Instantaneous) for Step-Up Main Transformers and Transmission lines Feeder relay PCS 9611.
Design calculations and settings of Earth Fault protection for Transmission lines.
Testing and commissioning of power house bridge crane as per FEM standards.
Powerhouse building and Spillway AC lighting design as well design of emergency lighting on
DC system.
Performed detailed grounding mesh calculations for powerhouse as per IEEE Std 80- 2000.
Performed short circuit calculations as per IEC 60909.
Performed UPS & battery sizing design & calculations in accordance with IEEE 485-1997.
Detailed design calculations for 230 V & 400 V A.C distribution system as well as cable sizing as
per IEC 60364.
Detailed design calculations for generator protection as per IEEE C37.101.
Design of structural lightning protection as per BS EN 62305.
Design analysis for liquid immersed and dry type transformers as per IEC-76, IEC-600726.
Design review of 0.4 kV, 6.3 kV and 11 kV switchgear panels.
Performed electrical design calculations for the distribution transformers and standby diesel
generators.
Performed design review of power transformer installation drawings & lightning protection.
Performed selection and sizing of lightning arresters as per IEC & IEEE standards.
Conducted site visits to determine and validate eld dimensions.
Processing of Commercial Invoices of equipment imported from abroad. Check and verify the
consignments arrived atsite from abroad.
Detailed design review of internal & external lighting schemes.
Work experience
Veri cation of interim payment certi cates (IPCs) of the contractors.
Meetings and frequent letter correspondence with Client and Contractor to settle down the
issues regarding designservices and installation of equipment at site.

Education
NWFP University of Electrical Engineering (POWER) 10/2009 09/2013
Engg & Technology Marks Obtained: 3.24 / 4 CGPA (81%)
Peshawar
Pakistan

Islamia College HSSC (Pre-Engineering) 2007 2009


Peshawar Marks Obtained: 898/1100 (81.64%)
Pakistan

Islamia Collegiate SSC 2005 2007


School Marks Obtained: 898/900 (87.11%)
Peshawar
Pakistan

Skills
Languages Computer Pro ciency
English Microsoft Word
Urdu Microsoft Excel
Pujabi Microsoft Powerpoint
Pushto Auto CAD
MATLAB
C++

You might also like