Buildings Department
April 2010
Introduction
Investigation
1
6. From the evidence available, the following situations were
revealed :
(c) Three columns, namely C11, C12 and C13, collapsed in the
incident. Remnants of the three columns were noted at ground
level after the collapse. The column layout diagram is at
Annex.
2
10. When these columns were assessed under the condition of
being subject to inadequate or improper repair with noticeable signs of
deterioration, the reduction of the effective column sizes had led to a
decrease in the bearing capacity of the columns. Based on the extent
of defects of these columns, the factor of safety so evaluated was still
found to be at an acceptable level and should not have caused the
building to collapse.
13. Once the three structurally unbalanced columns C11, C12 and
C13 reached their ultimate failure state, they would have crushed
progressively within a very short period of time and failed to support the
loading of the 5-storey building. This would have caused the lower
portion, about two storeys, of the building to collapse first.
3
15. The structural design adopted for the building structure of 45J
was simple-supported arrangement and the front portion of 45J was
partially structurally detached from the rear staircase portion.
Therefore the rear staircase of 45J and the adjoining building at 45H
(albeit column C9 at 3/F level of 45H was severely damaged and
dislocated) had remained standing after the collapse of the front portion
of 45J.
Conclusion
Buildings Department
April 2010
4
Annex