Professional Documents
Culture Documents
Contents:
MID 249 SID 240 Program Memory page 2
T2012704
General Information
At start-up a checksum is calculated for the software in
the Bodybuilder Module (BBM) flash memory. This is
compared with a previously stored checksum to check
that the software is correct.
Fault code
FMI 2
Intermittent or incorrect data
Conditions for fault code:
If the checksum calculated at start-up does not
agree with the previously saved checksum, the BBM
interprets this as a fault and a fault code is set.
Possible cause:
Software fault.
Faulty memory circuit.
Reaction from BBM:
The control unit continuously restarts.
Noticeable external symptom:
Yellow lamp is lit by the instrument control unit since
the BBM does not respond to the call.
Functions controlled by the BBM will not operate.
Actions:
Reprogram the BBM ECU. If the fault continues,
replace the BBM ECU.