You are on page 1of 4

ES NO.

01-000-013

TM

ENGINEERING PAGE: 14 OF 63
STANDARD DATE: JULY 12, 2001
TITLE: CONTROL AND CHOKE VALVE FLOW TEST DATA REVISION: C (01/08)

P25-15K ENHANCED TRIM (THEORETICAL) CHOKE ORIFICE SIZING SHEET

MIC PERCENT BEAN SIZE STEM TRAVEL PERCENT SIGNAL


CV
(STEPS)* OPEN 1/64 in. mm (in.) TRAVEL (4 - 20 mA)
0 0.0 0.0% 0 0 0.000 0.0% 4.000
1 0.0 0.0% 0 0 0.013 0.9% 4.142
2 0.0 0.0% 0 0 0.025 1.8% 4.283
3 0.0 0.0% 0 0 0.038 2.7% 4.425
4 0.0 0.0% 0 0 0.050 3.5% 4.566
5 0.0 0.0% 0 0 0.063 4.4% 4.708
6 0.0 0.0% 0 0 0.075 5.3% 4.850
7 0.0 0.0% 0 0 0.088 6.2% 4.991
8 0.0 0.0% 0 0 0.100 7.1% 5.133
9 0.0 0.0% 0 0 0.113 8.0% 5.274
10 0.0 0.0% 0 0 0.125 8.8% 5.416
11 0.0 0.0% 0 0 0.138 9.7% 5.558
12 0.0 0.0% 0 0 0.150 10.6% 5.699
13 0.0 0.0% 0 0 0.163 11.5% 5.841
14 0.0 0.0% 0 0 0.175 12.4% 5.982
15 0.0 0.0% 0 0 0.188 13.3% 6.124
16 0.0 0.0% 0 0 0.200 14.2% 6.265
17 0.0 0.0% 0 0 0.213 15.0% 6.407
18 0.0 0.0% 0 0 0.225 15.9% 6.549
19 0.0 0.0% 0 0 0.238 16.8% 6.690
20 0.0 0.0% 0 0 0.250 17.7% 6.832
21 0.0 0.0% 0 0 0.263 18.6% 6.973
22 0.0 0.0% 0 0 0.275 19.5% 7.115
23 0.0 0.0% 0 0 0.288 20.4% 7.257
24 0.0 0.1% 2 1 0.300 21.2% 7.398
25 0.1 0.2% 5 2 0.313 22.1% 7.540
26 0.2 0.4% 7 3 0.325 23.0% 7.681
27 0.3 0.7% 8 3 0.338 23.9% 7.823
28 0.4 0.9% 10 4 0.350 24.8% 7.965
29 0.5 1.2% 11 4 0.363 25.7% 8.106
30 0.6 1.5% 12 5 0.375 26.5% 8.248
31 0.8 1.8% 14 5 0.388 27.4% 8.389
32 0.9 2.2% 15 6 0.400 28.3% 8.531
33 1.1 2.5% 16 6 0.413 29.2% 8.673
34 1.2 2.8% 17 7 0.425 30.1% 8.814
35 1.3 3.1% 18 7 0.438 31.0% 8.956
36 1.5 3.5% 19 7 0.450 31.9% 9.097
37 1.7 4.0% 20 8 0.463 32.7% 9.239
38 2.0 4.7% 22 9 0.475 33.6% 9.381
ES NO. 01-000-013

TM

ENGINEERING PAGE: 15 OF 63
STANDARD DATE: JULY 12, 2001
TITLE: CONTROL AND CHOKE VALVE FLOW TEST DATA REVISION: C (01/08)

P25-15K ENHANCED TRIM (THEORETICAL) CHOKE ORIFICE SIZING SHEET

MIC PERCENT BEAN SIZE STEM TRAVEL PERCENT SIGNAL


CV
(STEPS)* OPEN 1/64 in. mm (in.) TRAVEL (4 - 20 mA)
39 2.4 5.5% 23 9 0.488 34.5% 9.522
40 2.7 6.4% 25 10 0.500 35.4% 9.664
41 3.1 7.2% 27 11 0.513 36.3% 9.805
42 3.5 8.1% 28 11 0.525 37.2% 9.947
43 3.9 9.0% 30 12 0.538 38.1% 10.088
44 4.2 9.9% 31 12 0.550 38.9% 10.230
45 4.6 10.7% 33 13 0.563 39.8% 10.372
46 5.0 11.6% 34 14 0.575 40.7% 10.513
47 5.4 12.6% 35 14 0.588 41.6% 10.655
48 5.8 13.6% 37 15 0.600 42.5% 10.796
49 6.2 14.6% 38 15 0.613 43.4% 10.938
50 6.7 15.7% 40 16 0.625 44.2% 11.080
51 7.2 16.8% 41 16 0.638 45.1% 11.221
52 7.6 17.9% 42 17 0.650 46.0% 11.363
53 8.1 19.0% 44 17 0.663 46.9% 11.504
54 8.6 20.2% 45 18 0.675 47.8% 11.646
55 9.1 21.4% 46 18 0.688 48.7% 11.788
56 9.7 22.6% 47 19 0.700 49.6% 11.929
57 10.2 23.8% 49 19 0.712 50.4% 12.071
58 10.7 25.1% 50 20 0.725 51.3% 12.212
59 11.3 26.4% 51 20 0.737 52.2% 12.354
60 11.8 27.7% 53 21 0.750 53.1% 12.496
61 12.4 29.0% 54 21 0.762 54.0% 12.637
62 12.9 30.3% 55 22 0.775 54.9% 12.779
63 13.5 31.6% 56 22 0.787 55.8% 12.920
64 14.1 33.0% 57 23 0.800 56.6% 13.062
65 14.7 34.4% 59 23 0.812 57.5% 13.204
66 15.3 35.8% 60 24 0.825 58.4% 13.345
67 15.9 37.1% 61 24 0.837 59.3% 13.487
68 16.5 38.6% 62 25 0.850 60.2% 13.628
69 17.1 40.0% 63 25 0.862 61.1% 13.770
70 17.7 41.4% 64 26 0.875 61.9% 13.912
71 18.3 42.8% 65 26 0.887 62.8% 14.053
72 18.9 44.3% 66 26 0.900 63.7% 14.195
73 19.5 45.7% 68 27 0.912 64.6% 14.336
74 20.2 47.2% 69 27 0.925 65.5% 14.478
75 20.8 48.6% 70 28 0.937 66.4% 14.619
76 21.4 50.1% 71 28 0.950 67.3% 14.761
77 22.0 51.5% 72 28 0.962 68.1% 14.903
ES NO. 01-000-013

TM

ENGINEERING PAGE: 16 OF 63
STANDARD DATE: JULY 12, 2001
TITLE: CONTROL AND CHOKE VALVE FLOW TEST DATA REVISION: C (01/08)

P25-15K ENHANCED TRIM (THEORETICAL) CHOKE ORIFICE SIZING SHEET

MIC PERCENT BEAN SIZE STEM TRAVEL PERCENT SIGNAL


CV
(STEPS)* OPEN 1/64 in. mm (in.) TRAVEL (4 - 20 mA)
78 22.6 53.0% 73 29 0.975 69.0% 15.044
79 23.3 54.5% 74 29 0.987 69.9% 15.186
80 23.9 55.9% 75 30 1.000 70.8% 15.327
81 24.5 57.4% 76 30 1.013 71.7% 15.469
82 25.2 58.9% 77 30 1.025 72.6% 15.611
83 25.8 60.3% 78 31 1.038 73.5% 15.752
84 26.4 61.8% 79 31 1.050 74.3% 15.894
85 27.0 63.3% 79 32 1.063 75.2% 16.035
86 27.7 64.7% 80 32 1.075 76.1% 16.177
87 28.3 66.2% 81 32 1.088 77.0% 16.319
88 28.9 67.6% 82 33 1.100 77.9% 16.460
89 29.5 69.1% 83 33 1.113 78.8% 16.602
90 30.1 70.5% 84 33 1.125 79.6% 16.743
91 30.8 72.0% 85 34 1.138 80.5% 16.885
92 31.4 73.4% 86 34 1.150 81.4% 17.027
93 32.0 74.8% 86 34 1.163 82.3% 17.168
94 32.6 76.2% 87 35 1.175 83.2% 17.310
95 33.2 77.6% 88 35 1.188 84.1% 17.451
96 33.8 79.0% 89 35 1.200 85.0% 17.593
97 34.4 80.4% 90 36 1.213 85.8% 17.735
98 34.9 81.8% 90 36 1.225 86.7% 17.876
99 35.5 83.1% 91 36 1.238 87.6% 18.018
100 36.1 84.4% 92 36 1.250 88.5% 18.159
101 36.7 85.8% 93 37 1.263 89.4% 18.301
102 37.2 87.1% 93 37 1.275 90.3% 18.442
103 37.8 88.4% 94 37 1.288 91.2% 18.584
104 38.3 89.6% 95 38 1.300 92.0% 18.726
105 38.8 90.9% 95 38 1.313 92.9% 18.867
106 39.4 92.1% 96 38 1.325 93.8% 19.009
107 39.9 93.3% 96 38 1.338 94.7% 19.150
108 40.4 94.5% 97 39 1.350 95.6% 19.292
109 40.9 95.6% 98 39 1.363 96.5% 19.434
110 41.4 96.8% 98 39 1.375 97.3% 19.575
111 41.8 97.9% 99 39 1.388 98.2% 19.717
112 42.3 99.0% 99 39 1.400 99.1% 19.858
113 42.7 100.0% 100 40 1.413 100.0% 20.000
THERE IS AN INITIAL STEM MOVEMENT OF 0.290 INCHES THAT HAS A ZERO-FLOW CONDITION.
THIS IS THE ISOLATION ZONE BEFORE THE FIRST PORTS BEGIN TO BE UNCOVERED.
* FOR VALVES ACTUATED WITH STEPPING ACTUATORS.
ES NO. 01-000-013

TM

ENGINEERING PAGE: 17 OF 63
STANDARD DATE: JULY 12, 2001
TITLE: CONTROL AND CHOKE VALVE FLOW TEST DATA REVISION: C (01/08)

P25-15K ENHANCED TRIM (THEORETICAL)

45

40

35

30

25

Cv
20

15

10

0
0.0% 10.0% 20.0% 30.0% 40.0% 50.0% 60.0% 70.0% 80.0% 90.0% 100.0%
PERCENT TRAVEL

You might also like