Process Analyzer Sample Probe Assembly (SPA)

with Conax Buffalo Packing Gland (PG)


Sample Probe with Welded Stop Collar and Angled End for
On-Line Extraction of Process Liquids or Gases

The Conax Buffalo Sample Probe Assembly (SPA) is used to hot-tap a sample probe into a process through a process
isolation valve as depicted below.
Optional materials for the Sample Probe and the Conax Buffalo Packing Gland body (wetted components) are available.
Refer to the Conax Pressure and Vacuum Sealing Assemblies Catalog #5001B or our website for available options such as:
316L SST Monel 405
316 NACE SST Hastelloy C276
316L CRN (gland body only) Inconel 600
Refer to the Conax Pressure and Vacuum Sealing Assemblies Catalog #5001B for temperature and pressure ratings
for static conditions. Pressure ratings are reduced when the sealing gland cap is loosened to allow for the inser-
tion or extraction of the Sample Probe.

CONAX SAMPLE PROBE FLANGED CONNECTION SAMPLE PROBE VALVE*


WITH WELDED STOP OR WELD-O-LET*

**

CONAX
FLOW

CONAX BUFFALO PACKING GLAND

BALL VALVE FOR INSERTION AND REMOVAL*


NOTES:
* THESE ITEMS TO BE PROVIDED BY END USER
** END USER TO TRIM SAMPLE PROBE SUCH THAT
THE LENGTH OF THE SAMPLE PROBE EXTENDING
BEYOND THE CONAX BUFFALO PACKING GLAND
IS AS SHORT AS PRACTICAL.

Pressure and Vacuum Sealing Assembly Catalog #5001B

For more information call: 1.800.223.2389 Email: conaxbuf@conaxbuffalo.com Visit our website: www.conaxbuffalo.com
How to Configure the Model Number of an SPA Assembly
Standard Conax Packing Gland (PG) model numbers and configurations apply. Sealing glands are supplied loose unless otherwise indicated.
Example model number: SPA/PG5-500-A-T/500X120W(S304)-45-1-36

Product Sealing Tube OD Tube Wall Tube A Tube End B Overall


Name Gland Used* Material Angle Dimension Tube
(if none (S304 or (90, 60, 45 (1/4 increments Length
indicate X) S316) or 30 1 = 1/4) (inches)
SPA PG5-500-A-T 500 120W (S304) 45 1 36
STOP COLLAR
.375 OD X .25 (.250 TUBE)
.500 OD X .25 (.375 TUBE)
B .500 OD X .25 (.500 TUBE)

PLASMA WELD

Standard Tube Sizes* Additional Considerations


Other sizes and materials available on request. CAUTION. The end user must take the necessary safety
precautions when loosening the cap of the Conax sealing
OD WALL ID (REF) MATERIAL gland when inserting or extracting the Sample Probe into
pressurized environments. The end user is responsible to
0.035 .180 S304 control any leakage of process fluids that may occur during
.250
0.025 .200 S316 insertion or extraction of the Sample Probe.
0.040 .295 S304 The end user is responsible for determining the appropriate
.375 Sample Probe material, diameter and wall thickness for the
0.040 .295 S316
process environment and flow rates.
0.049 .402 Conax Buffalo Technologies is not responsible for the
.500 S304
0.120 .250 operation of the Conax Packing Gland (PG) assembly once the
*Tubing is seamless or welded and annealed. cap is loosened to allow for the insertion or extraction of the
Sample Probe.
Typically, when properly installed, the angled Sample Probe
For more information about tip should have the long side upstream. This reduces the
particulates entering the Sample Probe and into the process
Conax Buffalo Technologies, analyzer filter. The Sample Probe immersion length should be
visit our website: designed to obtain a process sample close to the center third
of the pipe. It is suggested that the end user mark the Sample
www.conaxbuffalo.com Probe end with an indelible ink marker relative to the angled
end for proper orientation into the process.

2300 Walden Avenue


C E R TIFI
EM
Buffalo, New York 14225, USA ST
CA
T
SY

IO
N

Fax: 716-684-7433 Phone: 716-684-4500


IS O 9

Toll free in the USA at 1-800-223-2389


E-mail: conaxbuf@conaxbuffalo.com 01
0

:2 0 0
0
Website: www.conaxbuffalo.com

2006 Conax Buffalo Technologies Bulletin 6055 11/06

You might also like