You are on page 1of 3

EXPERIMENT-6[Gauss-Seidal]

Problem:
The magnitude at bus 1 is adjusted to 1.05pu. The scheduled loads at buses 2 and
3 are marked on the diagram. Line impedances are marked in p.u. The base value is
100kVA. The line charging susceptances are neglected. Determine the phasor values of
the voltage at the
Load bus 2 and 3.
(i) Find the slack bus real and reactive power.
(ii) Verify the result using MATLAB.

MANUEL CALCULATION:
MATLAB CODING:
y12=10-j*20;
y13=10-j*30;
y23=16-j*32;
V1=1.05+j*0;
V2=1+j*0;
V3=1+j*0;
S2=-2.566-j*1.102;
S3=-1.386-j*.452;
iter =0;
for I=1:10;
iter=iter+1;
V2 = (conj(S2)/conj(V2)+y12*V1+y23*V3)/(y12+y23);
V3 = (conj(S3)/conj(V3)+y13*V1+y23*V2)/(y13+y23);
disp([iter, V2, V3])
end
V2= .98-j*.06;
V3= 1-j*.05;
I12=y12*(V1-V2); I21=-I12;
I13=y13*(V1-V3); I31=-I13;
I23=y23*(V2-V3); I32=-I23;
S12=V1*conj(I12); S21=V2*conj(I21);
S13=V1*conj(I13); S31=V3*conj(I31);
S23=V2*conj(I23); S32=V3*conj(I32);
I1221=[I12,I21]
I1331=[I13,I31]
I2332=[I23,I32]
S1221=[S12, S21 (S12+S13) S12+S21]
S1331=[S13, S31 (S31+S32) S13+S31]
S2332=[S23, S32 (S23+S21) S23+S32]

You might also like