You are on page 1of 1

1.Aconcentrictubeheatexchangeruseswater(Cp=4178J/kg.

K),whichisavailableat
15oCtocoolethyleneglycol(Cp=2650J/kg.K)from100to60 oC.Thewaterandglycol
flowratesareeach0.5kg/s.Determinetheeffectivenessoftheexchanger.

2. (Ref.1)Asinglepassshellandtubeheatexchangercontains80steeltubes(k=25
Btu/hrftoF).TheIDofthetubesis0.732in.,andtheODis1.0in.Theshellsideofthe
exchangercontainssaturatedsteamat330oF,andwaterpassesthroughthetubes.The
unitisdesignedwithsufficienttubeareatopermit15,000gphofwatertobeheatedfrom
70to140oF.Inthecourseofthisdesign,adirtcoefficienth dof1000Btu/hrft2oFwas
assumedtoallowforscalingonthewatersideofthetube.Thefilmcoefficientforthe
steamis2000Btu/hrft2oF.Thefilmcoefficientforthewateris600Btu/hrft2oF.No
safety factor other than the one scale value was used in carrying out the exchanger
design. Estimate the temperature of saturated steam which must be used when the
exchangerisnew(i.e.,noscalepresent)ifthewaterenterstheunitatarateof15,000gph
andisheatedfrom70to140oF.Cpofwater=1Btu/lboF1ft3=7.48gal.Waterdensity
=62.3lb/ft3.
1 = 1 = 1 + 1 + ro - ri + 1 + 1
i Ai Uo A0 hi Ai hdi Ai kAlm hdo Ao ho Ao
U

3. (Ref.2)Hotoilataflowrateof3.00kg/s(C p =1.92kJ/kgoK)entersanexisting
counterflowexchangerat400oKandiscooledbywaterenteringat325 oKandflowingat
arateof0.70kg/s.TheoverallU=350W/m 2oKandareaA=12.9m2.Calculatethe
heattransferrateandtheexitoiltemperature.

4. (Ref.2)Inasinglepasscounterflowheatexchanger,10,000lb/hrofwaterentersat
60oFandcools20,000lb/hrofoilhavingaspecificheatof0.50Btu/lboFfrom200oFto
150oF.Iftheoverallheattransfercoefficientis50Btu/hrft2oF,determinethesurface
arearequired.

5.(Ref.2)Saturatedsteamat0.14bariscondensedinashellandtubeheatexchanger
withoneshellpassandtwotubepassesconsistingof130brasstubes(perpass),each
withalengthperpassof2m.Thetubeshaveinnerandouterdiametersof13.4and15.9
mm,respectively.Coolingwaterentersthetubesat20oCwithameanvelocityof1.25
m/s.Theheattransfercoefficientforcondensationontheoutersurfacesofthetubesis
13,500W/m2oK.Determinetheoverallheattransfercoefficient,thecoolingwateroutlet
temperature,andthesteamcondensationrate.

6.RuntheprogramMicroplantasaNoviceTroubleshooterandturninthelastdisplay
oftheprogram.