ArcelorMittal Solutions in SteelTM for Construction

Galvanize, Galvanneal, & Electrogalvanize


Steel Fact Sheet

For Multiple Applications and Product Description


Long Lasting Corrosion Protection
Hot Dip Galvanize (HDG or GI) is
ArcelorMittal offers a variety of Galvanized produced at numerous ArcelorMittal
Steel Sheet Products which are zinc coated galvanizing facilities in Canada and the USA
steel products with long lasting corrosion on continuous lines by passing pre-heated
performance and paintability for a diverse continuous strip through a bath of molten
range of construction applications and zinc. The required zinc coating thickness for
environments. The galvanic and barrier different coating specifications is achieved
properties of the zinc coating protects as the result of passing the hot dipped
the base steel and any cut edges from strip through a variable low pressure, high
corrosion and provides a good surface for volume air stream called an air knife prior
paint for additional barrier protection and to solidification of the zinc coating. In
aesthetics. addition, based on the application, the zinc
coating can be produced with minimized steel surface. As with HDG, the required
The galvanized products offered by (no) spangle, be a light to heavy zinc zinc coating thickness for different coating
ArcelorMittal include Hot Dip Galvanize coating for additional corrosion protection, specifications is achieved by passing the
(most commonly used) which can be and can be inline or post temper rolled if a hot dipped strip through an air knife just
produced with a wide range of light to smoother surface is required. before the galvannealing furnace. The
heavy zinc coatings, Hot Dip Galvanneal zinc-iron alloy coating has no spangle, has
which consists of light hot dipped zinc Galvanneal (GA) is produced at a uniform grey matte appearance, and
coatings which are heat treated/annealed ArcelorMittal galvanizing facilities in Canada the coating weights are typically less than
after coating to produce a zinc-iron alloy and the USA on continuous lines by passing most HDG products. This material can
for improved weldability and paintability, pre-heated continuous strip through a also be temper rolled after coating for an
and Electrogalvanize which consists of a bath of molten zinc. In this case after zinc extra smooth surface for surface critical
precise light electroplated coating of zinc coating, the strip is passed through an applications.
typically for painted applications. annealing furnace which transforms the
zinc into a zinc-iron alloy coating on the Electrogalvanize (EG) is produced on an
ArcelorMittal Electrogalvanizing Line in the
USA. On this continuous line, previously
annealed continuous strip is passed through
a series of plating cells where zinc is
electrolytically plated onto the strip. By
regulating the amount of electricity used,
a precise uniform coating of zinc is applied
to the strip and an air knife is not needed
for zinc coating control. No pre- or post-
heating of the strip is needed on an EG
Line, and the zinc coatings produced are
light weight zinc coatings with no spangle,
have a uniform appearance, and are
used primarily for surface critical painted
applications.
Product Characteristics boxes, pools, building components,
culverts, grain bins, truss plates, water
Proven Corrosion Resistance heaters, and many other applications
For similar unpainted galvanize applications, Galvanneal (bare/prepainted) for floor
the corrosion performance is directly decking, commercial doors, and corner
related to the zinc coating weight, with beads
heavier zinc coating weights giving better Electrogalvanize (prepainted)
performance by providing increased for doors, ceiling grid systems, and
protection and more sacrificial zinc to miscellaneous construction components
prevent corrosion of the base steel and
any cut edges. In addition, painting of Prepainted Galvanize
galvanize products provides additional Galvanized sheet steel can also be ordered
barrier protection, extended product life, as a prepainted coil. Prepainted Galvanize
and aesthetics. provides additional paint barrier protection
while offering a wide assortment of
Cut Edge Protection attractive colors and paint systems to fit
The zinc coating provides galvanic sacrificial many unique needs and applications, and
cut edge protection to prevent corrosion of can offer improved properties in:
the exposed edges. For these applications, Corrosion resistance
as steel thickness is increased, heavier Solvent, chemical and stain resistance
galvanize coating should be used to insure Adhesion (for bonding or foaming)
sufficient galvanic edge protection for the Mechanical properties: hardness,
increased cut edge surface area. toughness and flexibility
Color and aesthetic properties:
Enhanced Surface Treatment appearance (gloss/matte and smooth/
Applications texture) and opacity
ArcelorMittal offers a variety of
surface treatments suited to specific Hot Dip Galvanize, Galvanneal, and Durability
manufacturing and application needs. Electrogalvanize have many proven Energy Efficiency
Unpainted Galvanize can be passivated applications in Commercial, Industrial, Meeting health, safety and environmental
with a chemical treatment and can be Institutional, Agricultural, and Residential regulations
produced non-oiled or oiled. Surface Construction. Depending on paint requirements and
treatments that are RoHS compliant are Example applications for each product are exposure, a variety of polyester, silicon
also available. If paint is specified, galvanize shown below (but not limited to): modified polyester, fluoropolymer,
steel can be ordered as prepainted coil. This polyurethane, and plastisol paint systems
Hot Dip Galvanize (bare/pre-painted)
option offers an additional layer of paint are available, and should be specified with
for roofing, cladding (siding), ceiling
barrier protection in a wide assortment of assistance from ArcelorMittal. A schematic
grid systems, light steel framing, garage
attractive colors and paint systems. of a typical paint system and the benefits
doors, major appliances, HVAC, electrical
of each component are shown in Figure 1.

Product Availability
Gauge (in) Width (in)
Products Grades Coating Weights
Min. Max. Max.
G30, G40, G60, G90, G115, G140, G165, G200,
Hot Dip CS, DDS, EDDS, 0.011 0.168 72
G235 (Z90, Z120, Z180, Z275, Z350, Z450,
Galvanized FS, SS, HSLA (0.28 mm) (4.27 mm) (1829 mm)
Z610, Z720)
CS, DS, DDS, EDDS, 0.011 0.168 72 A25, A30, A40, A60
Galvanneal
FS, SS, HSLA (0.28 mm) (4.27 mm) (1829 mm) (ZF75, ZF90, ZF120, ZF180)
20G/20G, 30G/30G, 40G/40G, 50G/50G,
Electro- CS, DS, DDS, EDDS, 0.019 0.081 72
60G/60G, 70G/70G, 80G/80G, 90G/90G,
Galvanize FS, SS, HSLA (0.48 mm) (2.06 mm) (1829 mm)
100G/100G
Paint Systems: Acrylic, Polyester, Silicon Modified
0.011 0.058 61.5
Prepaint HDG, EG Polyester (SMP), Fluoropolymer (PVDF),
(0.28 mm) (1.47 mm) (1562 mm)
Polyurethane, Plastisols

Notes:
Gauge, width, and available coating weights are overall capabilities and vary by production line. Please inquire with exceptions.
Pre-painted products at wider widths/heavier gauges may be available depending on coil coater used.
On bare heavier gauge galvanize applications with cut edges, heavier galvanize coatings (>G90) should be used to ensure galvanic protection of the cut edge.
(2:12 or less) roofing. These performance
Durable, beautiful finishes -
polyesters, silicon modified
requirements can also be met with the use
polyesters, fluoropolymers, of select prepainted systems on Galvanized
polyurethanes, plastisols -
in a wide range of proven colors products.

High performance primers Points to Remember


are key to long term corrosion
resistance and paint adhesion
Compatibility with Dissimilar Metals and
Pretreatment provides excellent
corrosion resistance and adhesion Environmental Affects
For Galvanize coated steels, contact with
Zinc coating
lead or copper must be avoided (including
products containing lead or copper such as
Steel sheet pressure treated lumber) as it can result in
accelerated corrosion.
Backer coats to enhance
corrosion resistance and
Figure 1 minimize abrasion damage In addition, Galvanize coated steels are not
recommended (or require additional zinc
coatings and/or paint to limit corrosion)
Recycling & Sustainability initial SR value of 0.25 or higher for steep for applications near seawater (chlorides
slope (more than 2:12) roofs and 0.15 or accelerate corrosion) or other harsh
Recycling higher after 3 years, or an initial SR value corrosive environments which have heavy
All galvanized steel products are essentially of 0.65 or higher for low slope (2:12 or exposure to corrosive chemicals (such as
100% recyclable at the end of their usable less) roofs and 0.50 or higher after 3 years. caustic soda, ammonia, lime, hydrochloric
life and can be used in the basic oxygen The use of select prepainted systems acid, nitric acid, hydrogen sulfide, sulfuric
furnace (BOF) or electric arc furnace (EAF) (typically lighter colors) on Galvanized acid, sulfur dioxide), or excessive water
steel making processes to make new steel cool roofing products can meet or exceed contact with wet materials or standing
products. This reduces the amount of these ENERGY STAR requirements resulting water.
raw materials and energy needed along in significant savings in a buildings air
with greenhouse gas generation. Steel conditioning requirements. In addition, For all outdoor, bare HDG applications
construction products are generally higher SR values are also now achievable a minimum G90 (Z275) or heavier
produced with at least 25% and up to on select dark color paint systems which is recommended, and for additional
nearly 100% recycled steel. allow architects more color choices while protection in corrosive or polluted
still achieving energy savings (though these environments, prepainted galvanized
Energy Efficiency systems may not qualify for the ENERGY products should be considered.
Solar Reflectance (SR) or Reflectivity is the STAR rating).
Galvanize and GalvalumeTM steel should
ability of a material to reflect solar energy The Solar Reflectance Index (SRI) is used not be combined on the same building
from its surface back into the atmosphere. to determine compliance with Leadership elevation because Galvanize will likely
The SR value is a number from 0 (100% in Energy and Environmental Design exhibit corrosion before Galvalume. As a
absorbance) to 1.0 (100% reflectance). (LEEDTM) requirements for reduced heat design practice, when both materials are
For construction roofing products, a higher island effect and is calculated using values in contact, always use Galvalume steel
value indicates less energy absorption for reflectance and emissivity (a materials downstream from unpainted Galvanized
and lower roof surface temperature and ability to release absorbed energy). To steel, otherwise accelerated corrosion of
subsequent heat transfer into a building. meet LEED requirements, a roofing material the Galvanized steel can occur. However,
The US Environmental Protection Agency must have an SRI value of 29 or higher for Galvalume steel can be used for the roof
(EPA) and Department of Energy (DOE) steep slope (more than 2:12) roofing, or and Galvanized steel for the sides of a
ENERGY STARTM Program require an an SRI value of 78 or higher for low slope building.

Total Re-emitted
Solar Reflected Energy
Radiation Radiation
Convection

Roof
Surface
Absorbed Energy Layer

Net Heat Flux into Roof


Handling and Storage
To preserve the surface, handling should
only be carried out using clean, dry gloves.
Do not slide sheets over rough surfaces or
each other.

As with painted steel products, bundles of


Galvanize steel sheets or products made
from Galvanize steel in all finishes must be
kept dry in transit. After transit, material
should then be covered and stored off
the ground, at a slight angle, to prevent
water or condensation from being trapped
between adjacent sheet surfaces. in a bath of molten zinc which results applications such as connecting strapping
If the bundles become wet, sheets should in thicker continuous zinc coatings with to an ACQ pressure treated wood framing
be separated, wiped with a clean cloth good galvanic and barrier protection. member), or stainless steel (300 series
without delay, and then placed so that air However excessive zinc may be recommended), or other fasteners or
circulation completes the drying process. deposited in the base of the screw coatings as recommended by the fastener
These procedures are recommended threads. manufacturer. In addition non-permeable
to avoid possible deterioration of the Specialty Coated Fasteners are membrane materials (such as ice/water
coating, which could result in non-uniform produced with metallic and polymer shield) should be used between galvanize
appearance. coatings typically in a dip, spin, bake panels, components, etc., in direct contact
operation, and offer improved fastener with pressure treated wood.
Joining and Sealing corrosion performance over just zinc
plating. This fastener also typically has a For sealing, neutral cure silicone or butyl
Common fasteners used on galvanize, rubber based sealants should be used.
built-in gasket.
galvanneal, and electrogalvanize steel sheet Sealants containing acetic acid or amines
Stainless Steel Fasteners are typically
include: should not be used on galvanized steel.
made of 304 or 316 stainless steel
Mechanical Zinc Plated Fasteners are Check with your sealant supplier for brand
which contains ferrous alloys containing
produced by impacting/adhering zinc name recommendations.
chromium and nickel which gives the
to the fastener surface which results in
steel very good corrosion resistance.
a porous light to heavy zinc coating (as Special Customer Note:
These generally require a non-conductive The Information in this Fact Sheet is provided for the
required) that may have a top sealer,
gasket between the stainless steel general guidance of customers and does not imply any
and provides good galvanic corrosion
fastener and galvanized material, and due warranty. Information provided is based on research
protection (which improves with zinc conducted by ArcelorMittal and other organizations.
to higher cost are typically used in highly
coating thickness). However non- Interpretation and/or use of this information is the
corrosive environments. sole responsibility of the user. For further details,
uniform zinc may be deposited in the
In addition, washers made of EPDM or a contact ArcelorMittal USA or Canada.
base of the screw threads.
Electro-Zinc Plated Fasteners are similar material should be used, fasteners TM ArcelorMittal (Logo/Slogan) is a trademark of
produced by acid cleaning the fastener containing lead or copper should be ArcelorMittal.
prior to electroplating zinc, followed avoided along with lead headed nails and TM - Solutions in Steel is a trademark of ArcelorMittal
lead washers. The ultimate selection of Dofasco.
by a sealer for additional temporary
TM - Galvalume is a trademark of ArcelorMittal
protection which results in a fastener suitable fasteners to be used rests solely Dofasco in Canada, and a trademark of BIEC
with good galvanic and barrier with the buyer. International Inc. in the United States.
protection. They are the most commonly TM ENERGY STAR is a trademark of the US
used type of fastener. For construction projects using pressure Environmental Protection Agency.
treated wood, fasteners should be TM - LEED (Leadership in Energy and Environmental
Hot Dip Galvanized Fasteners are Design) is a registered trademark of U.S.G.B.C.
produced by immersing the fasteners hotdipped galvanized (for limited

ArcelorMittal Dofasco T 1-800-816-6333


Box 2460, 1330 Burlington Street East E customer-inquiries.dofasco@arcelormittal.com
Hamilton, ON L8N 3J5
Canada

ArcelorMittal USA T 1-800-422-9422


1 South Dearborn Street E constructioninquiries@arcelormittal.com
Chicago, IL 60603
USA www.arcelormittal.com

You might also like