eNodeB V100R003C00 Parameter Reference

Copyright Huawei Technologies Co., Ltd. 2012. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of H

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All
document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statem
"AS IS" without warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this
information, and recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address:

Website:
Email:
NodeB V100R003C00 Parameter Reference

yright Huawei Technologies Co., Ltd. 2012. All rights reserved.


rt of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologie

emarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
her trademarks and trade names mentioned in this document are the property of their respective holders.

urchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the prod
ment may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, a
S" without warranties, guarantees or representations of any kind, either express or implied.
nformation in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensu
mation, and recommendations in this document do not constitute a warranty of any kind, express or implied.

awei Technologies Co., Ltd.


Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
http://www.huawei.com
support@huawei.com
e

consent of Huawei Technologies Co., Ltd.

customer. All or part of the products, services and features described in this
ct, all statements, information, and recommendations in this document are provided

ration of this document to ensure accuracy of the contents, but all statements,
ed.
Purpose
This document describes eNodeB V100R003C00 parameters.

Intended Audience
This document is intended for:
Network planners
System engineers
Field engineers
Shift operators
Site maintainers
Network operators

Parameter Attribute Description


The following table describes the attributes of each parameter.
Parameter Attribute
MO
Parameter ID
Parameter Name
NE
MML Command
Meaning
IsKey
Mandatory
Dynamic Attribute
Feature ID
Feature Name
Value Type
GUI Value Range
Enumeration Number/Bit
Unit
Actual Value Range

Default Value

Recommended Value
Impact
Parameter Relationship

Access
Service Interrupted After Modification
Interruption Scope
Interruption Duration (min)
Caution
Validation of Modification
Impact on Radio Network Performance
Introduced in Version
Attribute

Initial Value Source


V100R003C00 parameters.

ttributes of each parameter.


Description
Managed object of NE
Simple string for identifying a parameter
Name of the parameter
NEs on which the parameter is set
Man Machine Language (MML) command related to the parameter
Definition, purpose, and protocols of the parameter
Whether the parameter is used to identify an MO instance.
Whether the parameter is mandatory for creating an MO instance.
Whether the parameter is dynamic for an MO. If the parameter is not dynamic, it can be added, modifie
or removed; if the parameter is dynamic, it cannot.
ID of the feature that uses the parameter
Name of the feature that uses the parameter
Parameter value type
Parameter value range displayed on the GUI
Enumeration number corresponding to the GUI value of a parameter of the enumeration type, or bit
position corresponding to the GUI value of a parameter of the bit field type.
Unit for the GUI Value Range
Actual parameter value range corresponding to the GUI Value Range
Initial parameter value assigned by the system. There is no default value for a mandatory parameter.
None indicates that there is no default value. For a bit field parameter, the value ON of a sub-paramet
means that the bit representing the sub-parameter is set to 1, and the value OFF means that the bit is
set to 0.
Generally, it is displayed on the configuration window of an ADD command but not displayed on the
configuration window of a MOD/RMV/DSP/LST command.
Parameter values recommended for different scenarios
Parameter impact scope
Relationship with other parameters. For example, to use this parameter, you need to set related switch
and parameters.
Whether this parameter is Read & Write or Read Only. If a parameter is not dynamic and is read only,
can be set only when the MO is created and cannot be modified later. To modify the parameter, you mu
delete the MO first and then create it again.
Whether modifying the parameter value interrupts the ongoing services.
Possible interruption scope
Possible interruption duration (unit: minute)
Cautions to be taken during the modification
How this parameter takes effect and whether the equipment needs to be restarted after the modificatio
Impact of the parameter on radio network performance
Product version in which the parameter is introduced
Whether the parameter is a radio parameter, a transport parameter, or an equipment parameter.
Source for the initial configuration of a parameter. The initial value source can be:
Radio planning: The initial value of the parameter comes from radio network planning.
Transport planning: The initial value of the parameter comes from transport network planning.
Equipment planning: The initial value of the parameter comes from equipment planning.
Engineering design: The initial value of the parameter comes from function design.
Default/recommended value: The initial value uses the default or recommended value, where the
recommended value is preferential. The default/recommended value can be used in most scenarios an
adjusted for a specific scenario.
Not involved: The initial value of the parameter is not required.
MO Parameter ID Parameter Name NE MML Command
DLD ALDSW
ALD DEVICENO Device No. eNodeB DSP ALDVER
RST ALD
ALD RtmVendorCode Actual vendor code eNodeB None

Actual device serial


ALD RtmDeviceSerialNo eNodeB DSP ALDVER
No.

ALD DEVICENAME Device name eNodeB DSP ALDVER


DLD ALDSW
DLD RETCFGDATA
Control port cabinet
ALD CTRLPORTCN eNodeB DSP ALDVER
No. DLD ALDSW
RST ALD
DLD
SCN RETCFGDATA
ALD
Control port
ALD CTRLPORTSRN eNodeB DSP ALDVER
subrack No. DLD ALDSW
RST ALD
DLD
SCN RETCFGDATA
ALD
ALD CTRLPORTSN Control port slot No. eNodeB DSP ALDVER
RST ALD
SCN ALD
ALD ProtocolVersion Protocol version eNodeB DSP ALDVER

RtmTotalSubunitNu Actual subunit


ALD eNodeB None
m number

ALD HardwareVersion Hardware version eNodeB DSP ALDVER

ALD SoftwareVersion Software version eNodeB DSP ALDVER

ALD DeviceModel Device model eNodeB DSP ALDVER

DSP ALDVER
ALD DeviceType Device type eNodeB
SCN ALD
ADD RET
MOD RET
RET VENDORCODE Vendor code eNodeB
LST RET
ADD RET
SCN ALD
MOD RET
RET SERIALNO Serial No. eNodeB
LST RET
SCN ALD
ADD RET
RET RETTYPE RET type eNodeB MOD RET
LST RET
ADD RET
RET POLARTYPE Polar type eNodeB MOD RET
LST RET
ADD RET
RET SCENARIO Antenna scenario eNodeB MOD RET
LST RET
ADD RET
RET subunit
RET SUBUNITNUM eNodeB MOD RET
number ADD RET
LST RET
DSP RET
RET DEVICENO Device No. eNodeB LST RET
MOD RET
RMV RET
RET RtmVendorCode Actual vendor code eNodeB DSP RET

Actual device serial


RET RtmDeviceSerialNo eNodeB DSP RET
No.
ADD RET
RET DEVICENAME Device name eNodeB MOD RET
LST RET
ADD RET
Control port cabinet
RET CTRLPORTCN eNodeB MOD RET
No.
LST RET
ADD RET
Control port
RET CTRLPORTSRN eNodeB MOD RET
subrack No.
LST RET
ADD RET
RET CTRLPORTSN Control port slot No. eNodeB MOD RET
LST RET
RET ProtocolVersion Protocol version eNodeB DSP RET

RtmTotalSubunitNu Actual subunit


RET eNodeB DSP RET
m number

RET HardwareVersion Hardware version eNodeB None

RET SoftwareVersion Software version eNodeB None

RET DeviceModel Device model eNodeB None

RET DeviceType Device type eNodeB None


DSP
RETDEVICEDATA
LST
RetDeviceData DEVICENO Device No. eNodeB DSP
RETDEVICEDATA
RETDEVICEDATA
MOD
LST
RETDEVICEDATA
RetDeviceData SUBUNITNO Subunit No. eNodeB
RETDEVICEDATA
MOD
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BEARING Antenna bearing eNodeB
LST
MOD
RETDEVICEDATA
Antenna model RETDEVICEDATA
RetDeviceData MODELNO eNodeB
number LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BSID Base station Id eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BEAMWIDTH1 Beamwidth1 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BEAMWIDTH2 Beamwidth2 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BEAMWIDTH3 Beamwidth3 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BEAMWIDTH4 Beamwidth4 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData GAIN1 Gain1 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData GAIN2 Gain2 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData GAIN3 Gain3 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData GAIN4 Gain4 eNodeB
LST
RETDEVICEDATA
MOD
RETDEVICEDATA
RetDeviceData DATE Installed date eNodeB
LST
MOD
RETDEVICEDATA
Installed RETDEVICEDATA
RetDeviceData TILT eNodeB
mechanical tilt LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData INSTALLERID Installer Id eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BAND1 Band1 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BAND2 Band2 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BAND3 Band3 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData BAND4 Band4 eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData SECTORID Sector Id eNodeB
LST
MOD
RETDEVICEDATA
RETDEVICEDATA
RetDeviceData SERIALNO Serial No. eNodeB
LST
RETDEVICEDATA
DSP
RetDeviceData MaxTilt Max tilt eNodeB
RETDEVICEDATA
DSP
RetDeviceData MinTilt Min tilt eNodeB
RETDEVICEDATA
DSP RETPORT
RetPort CN Cabinet No. eNodeB LST RETPORT
MOD RETPORT
DSP RETPORT
RetPort SRN Subrack No. eNodeB LST RETPORT
MOD RETPORT
DSP RETPORT
RetPort SN Slot No. eNodeB LST RETPORT
MOD RETPORT
DSP RETPORT
RetPort PN Port No. eNodeB LST RETPORT
MOD RETPORT
Current alarm MOD RETPORT
RetPort THRESHOLDTYPE eNodeB
threshold LST RETPORT
MOD RETPORT
RetPort PWRSWITCH ALD power switch eNodeB
LST RETPORT
Overcurrent alarm MOD RETPORT
RetPort OCTHD eNodeB
clear threshold LST RETPORT
Overcurrent alarm MOD RETPORT
RetPort OOTHD eNodeB
occur threshold LST RETPORT
Undercurrent alarm MOD RETPORT
RetPort UCTHD eNodeB
clear threshold LST RETPORT
Undercurrent alarm MOD RETPORT
RetPort UOTHD eNodeB
occur threshold LST RETPORT

RetPort ALDCurrValue ALD current value eNodeB DSP RETPORT

ALD actual power


RetPort ALDRtmPwrSwitch eNodeB DSP RETPORT
switch
CLB RET
DLD RETCFGDATA
DSP RETSUBUNIT
RETSubUnit DEVICENO Device No. eNodeB LST
CLB RETSUBUNIT
RET
MODRETCFGDATA
DLD
RETSUBUNIT
DSP RETSUBUNIT
RETSubUnit SUBUNITNO Subunit No. eNodeB MODRETSUBUNIT
RETTILT
LST
MOD
RETSubUnit Status Online status eNodeB RETSUBUNIT
DSP RETSUBUNIT

RETSubUnit RtmTilt Actual tilt eNodeB DSP RETSUBUNIT


CLB RET
DLD ALDSW
RETSubUnit SECTORNO Sector Id eNodeB
DLD RETCFGDATA
DSP
MODRETSUBUNIT
Connect port 1
RETSubUnit CONNCN1 eNodeB RETSUBUNIT
cabinet No.
LST RETSUBUNIT
MOD
Connect port 1
RETSubUnit CONNSRN1 eNodeB RETSUBUNIT
subrack No.
LST RETSUBUNIT
MOD
Connect port 1 slot
RETSubUnit CONNSN1 eNodeB RETSUBUNIT
No.
LST RETSUBUNIT
MOD
Connect port 1 port
RETSubUnit CONNPN1 eNodeB RETSUBUNIT
No.
LST RETSUBUNIT
MOD
Connect port 2
RETSubUnit CONNCN2 eNodeB RETSUBUNIT
cabinet No.
LST RETSUBUNIT
MOD
Connect port 2
RETSubUnit CONNSRN2 eNodeB RETSUBUNIT
subrack No.
LST RETSUBUNIT
MOD
Connect port 2 slot
RETSubUnit CONNSN2 eNodeB RETSUBUNIT
No.
LST RETSUBUNIT
MOD
Connect port 2 port
RETSubUnit CONNPN2 eNodeB RETSUBUNIT
No.
LST RETSUBUNIT
MOD
RETSUBUNIT
RETSubUnit TILT Tilt eNodeB
MOD RETTILT
LST RETSUBUNIT
MOD
Tilt alarm error
RETSubUnit AER eNodeB RETSUBUNIT
range
LST RETSUBUNIT
ADD TMA
TMA subunit
TMA SUBUNITNUM eNodeB MOD TMA
number ADD TMA
LST TMA
DSP TMA
TMA DEVICENO Device No. eNodeB LST TMA
MOD TMA
RMV TMA
TMA RtmVendorCode Actual vendor code eNodeB DSP TMA

Actual device serial


TMA RtmDeviceSerialNo eNodeB DSP TMA
No.
ADD TMA
TMA DEVICENAME Device name eNodeB MOD TMA
LST TMA
ADD TMA
Control port cabinet
TMA CTRLPORTCN eNodeB MOD TMA
No.
LST TMA
ADD TMA
Control port
TMA CTRLPORTSRN eNodeB MOD TMA
subrack No.
LST TMA
ADD TMA
TMA CTRLPORTSN Control port slot No. eNodeB MOD TMA
LST TMA
TMA ProtocolVersion Protocol version eNodeB None

RtmTotalSubunitNu Actual subunit


TMA eNodeB DSP TMA
m number

TMA HardwareVersion Hardware version eNodeB None

TMA SoftwareVersion Software version eNodeB None

TMA DeviceModel Device model eNodeB None

TMA DeviceType Device type eNodeB None


DSP
TMADEVICEDATA
LST
TMADeviceData DEVICENO Device No. eNodeB DSP
TMADEVICEDATA
TMADEVICEDATA
MOD
LST
TMADEVICEDATA
TMADeviceData SUBUNITNO Subunit No. eNodeB
TMADEVICEDATA
MOD
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BEARING Antenna bearing eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BSID Base station Id eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BEAMWIDTH1 Beamwidth1 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BEAMWIDTH2 Beamwidth2 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BEAMWIDTH3 Beamwidth3 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BEAMWIDTH4 Beamwidth4 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData GAIN1 Gain1 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData GAIN2 Gain2 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData GAIN3 Gain3 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData GAIN4 Gain4 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData DATE Installed date eNodeB
LST
MOD
TMADEVICEDATA
Installed TMADEVICEDATA
TMADeviceData TILT eNodeB
mechanical tilt LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData INSTALLERID Installer Id eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BAND1 Band1 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BAND2 Band2 eNodeB
LST
TMADEVICEDATA
MOD
TMADEVICEDATA
TMADeviceData BAND3 Band3 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData BAND4 Band4 eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData SECTORID Sector Id eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData SERIALNO Serial No. eNodeB
LST
MOD
TMADEVICEDATA
Connect antenna TMADEVICEDATA
TMADeviceData MODELNO eNodeB
model number LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData GAINRESLUTION Gain resolution eNodeB
LST
MOD
TMADEVICEDATA
TMADEVICEDATA
TMADeviceData SUBUNITTYPE Subunit type eNodeB
LST
MOD
TMADEVICEDATA
Received max TMADEVICEDATA
TMADeviceData RXMAXFB eNodeB
frequency band LST
MOD
TMADEVICEDATA
Transmit max TMADEVICEDATA
TMADeviceData TXMAXFB eNodeB
frequency band LST
MOD
TMADEVICEDATA
Received min TMADEVICEDATA
TMADeviceData RXMINFB eNodeB
frequency band LST
MOD
TMADEVICEDATA
Transmit min TMADEVICEDATA
TMADeviceData TXMINFB eNodeB
frequency band LST
TMADEVICEDATA
DSP
TMADeviceData MaxSupportedGain Max supported gain eNodeB
TMADEVICEDATA
DSP
TMADeviceData MinSupportedGain Min supported gain eNodeB
TMADEVICEDATA
DSP TMASUBUNIT
LST TMASUBUNIT
TMASubUnit DEVICENO Device No. eNodeB
MOD
DSP TMASUBUNIT
TMASUBUNIT
LST TMASUBUNIT
TMASubUnit SUBUNITNO Subunit No. eNodeB
MOD
TMASUBUNIT
TMASubUnit RtmSectorId Actual sector Id eNodeB DSP TMASUBUNIT

TMASubUnit RtmGain Actual gain eNodeB DSP TMASUBUNIT

TMASubUnit RtmMode Actual mode eNodeB DSP TMASUBUNIT

TMASubUnit Status Online status eNodeB DSP TMASUBUNIT


MOD
TMASubUnit CONNPN Connect port No. eNodeB TMASUBUNIT
LST TMASUBUNIT
MOD
Connect port
TMASubUnit CONNCN eNodeB TMASUBUNIT
cabinet No.
LST TMASUBUNIT
MOD
Connect port slot
TMASubUnit CONNSN eNodeB TMASUBUNIT
No.
LST TMASUBUNIT
MOD
Connect port
TMASubUnit CONNSRN eNodeB TMASUBUNIT
subrack No.
LST TMASUBUNIT
MOD
TMASubUnit GAIN Gain eNodeB TMASUBUNIT
LST TMASUBUNIT
MOD
TMASubUnit MODE Mode eNodeB TMASUBUNIT
LST TMASUBUNIT
DSP BBP
BBP CN Cabinet No. eNodeB LST BBP
MOD BBP
DSP BBP
BBP SRN Subrack No. eNodeB LST BBP
MOD BBP
DSP BBP
BBP SN Slot No. eNodeB LST BBP
MOD BBP
MOD BBP
BBP ADMSTATE Administrative State eNodeB DSP BRD
LST BBP
ADD BRD
BBP WM Mode eNodeB MOD BBP
LST BBP
BBP PhyBrdType Physical board type eNodeB DSP BBP

BBP AlarmState Alarm Status eNodeB None

BBP OpState Operational State eNodeB None

BBP AvailabilityStatus Availability Status eNodeB None

BBP Elabel Electronic Label eNodeB None

BBP BoardType Type eNodeB None

BBP BoardSerial Serial Number eNodeB None

BBP BoardDesc Description eNodeB None

Date of
BBP BoardManu eNodeB None
Manufacture

BBP BoardVendor Vendor eNodeB None

BBP BoardIssue Issue Number eNodeB None

BBP RuType Config Type eNodeB None

BBP ObjectNumber Object Number eNodeB None

BBP ObjectType Object Type eNodeB None

BBP BoardTemperature Board Temperature eNodeB None

BBP HPATemperature HPA Temperature eNodeB None


BBP OperateResult Operate Result eNodeB None

BBP ServiceType Service Type eNodeB None

BBP DEVTYPE DEVTYPE eNodeB None

BBP NeName Office Name eNodeB None

BBP SoftVer Software Version eNodeB None

BBP HardVer Hardware Version eNodeB None

BBP BtrmVer BootRom Version eNodeB None

BBP HwTestTime Test Time eNodeB None

BBP TestResult Test Result eNodeB None

Downlink
BBP DLFREQ eNodeB None
Frequency

BBP ULFREQ Uplink Frequency eNodeB None

MPT CN Cabinet No. eNodeB None

MPT SRN Subrack No. eNodeB None

MPT SN Slot No. eNodeB None

MPT STANDBYSTATUS Standby Status eNodeB DSP BRD

MPT AlarmState Alarm Status eNodeB None

MPT OpState Operational State eNodeB None

MPT AvailabilityStatus Availability Status eNodeB None

MPT Elabel Electronic Label eNodeB None

MPT BoardType Type eNodeB None

MPT BoardSerial Serial Number eNodeB None

MPT BoardDesc Description eNodeB None

Date of
MPT BoardManu eNodeB None
Manufacture
MPT BoardVendor Vendor eNodeB None

MPT BoardIssue Issue Number eNodeB None

MPT RuType Config Type eNodeB None

MPT ObjectNumber Object Number eNodeB None

MPT ObjectType Object Type eNodeB None

MPT BoardTemperature Board Temperature eNodeB None

MPT HPATemperature HPA Temperature eNodeB None

MPT OperateResult Operate Result eNodeB None

MPT ServiceType Service Type eNodeB None

MPT DEVTYPE DEVTYPE eNodeB None

MPT NeName Office Name eNodeB None

MPT SoftVer Software Version eNodeB None

MPT HardVer Hardware Version eNodeB None

MPT BtrmVer BootRom Version eNodeB None

MPT HwTestTime Test Time eNodeB None

MPT TestResult Test Result eNodeB None

Downlink
MPT DLFREQ eNodeB None
Frequency

MPT ULFREQ Uplink Frequency eNodeB None

TRP CN Cabinet No. eNodeB LST UTRP

TRP SRN Subrack No. eNodeB LST UTRP

TRP SN Slot No. eNodeB LST UTRP

ADD BRD
TRP SUBTYPE SubType eNodeB
LST UTRP

TRP AlarmState Alarm Status eNodeB None


TRP OpState Operational State eNodeB None

TRP AvailabilityStatus Availability Status eNodeB None

TRP Elabel Electronic Label eNodeB None

TRP BoardType Type eNodeB None

TRP BoardSerial Serial Number eNodeB None

TRP BoardDesc Description eNodeB None

Date of
TRP BoardManu eNodeB None
Manufacture

TRP BoardVendor Vendor eNodeB None

TRP BoardIssue Issue Number eNodeB None

TRP RuType Config Type eNodeB None

TRP ObjectNumber Object Number eNodeB None

TRP ObjectType Object Type eNodeB None

TRP BoardTemperature Board Temperature eNodeB None

TRP HPATemperature HPA Temperature eNodeB None

TRP OperateResult Operate Result eNodeB None

TRP ServiceType Service Type eNodeB None

TRP DEVTYPE DEVTYPE eNodeB None

TRP NeName Office Name eNodeB None

TRP SoftVer Software Version eNodeB None

TRP HardVer Hardware Version eNodeB None

TRP BtrmVer BootRom Version eNodeB None

TRP HwTestTime Test Time eNodeB None

TRP TestResult Test Result eNodeB None


Downlink
TRP DLFREQ eNodeB None
Frequency

TRP ULFREQ Uplink Frequency eNodeB None

USCU CN Cabinet No. eNodeB None

USCU SRN Subrack No. eNodeB None

USCU SN Slot No. eNodeB None

USCU AlarmState Alarm Status eNodeB None

USCU OpState Operational State eNodeB None

USCU AvailabilityStatus Availability Status eNodeB None

USCU Elabel Electronic Label eNodeB None

USCU BoardType Type eNodeB None

USCU BoardSerial Serial Number eNodeB None

USCU BoardDesc Description eNodeB None

Date of
USCU BoardManu eNodeB None
Manufacture

USCU BoardVendor Vendor eNodeB None

USCU BoardIssue Issue Number eNodeB None

USCU RuType Config Type eNodeB None

USCU ObjectNumber Object Number eNodeB None

USCU ObjectType Object Type eNodeB None

USCU BoardTemperature Board Temperature eNodeB None

USCU HPATemperature HPA Temperature eNodeB None

USCU OperateResult Operate Result eNodeB None

USCU ServiceType Service Type eNodeB None

USCU DEVTYPE DEVTYPE eNodeB None


USCU NeName Office Name eNodeB None

USCU SoftVer Software Version eNodeB None

USCU HardVer Hardware Version eNodeB None

USCU BtrmVer BootRom Version eNodeB None

USCU HwTestTime Test Time eNodeB None

USCU TestResult Test Result eNodeB None

Downlink
USCU DLFREQ eNodeB None
Frequency

USCU ULFREQ Uplink Frequency eNodeB None

BbuFan CN Cabinet No. eNodeB None

BbuFan SRN Subrack No. eNodeB None

BbuFan SN Slot No. eNodeB None

BbuFan AlarmState Alarm Status eNodeB None

BbuFan OpState Operational State eNodeB None

BbuFan AvailabilityStatus Availability Status eNodeB None

BbuFan Elabel Electronic Label eNodeB None

BbuFan BoardType Type eNodeB None

BbuFan BoardSerial Serial Number eNodeB None

BbuFan BoardDesc Description eNodeB None

Date of
BbuFan BoardManu eNodeB None
Manufacture

BbuFan BoardVendor Vendor eNodeB None

BbuFan BoardIssue Issue Number eNodeB None

BbuFan RuType Config Type eNodeB None

BbuFan ObjectNumber Object Number eNodeB None


BbuFan ObjectType Object Type eNodeB None

BbuFan BoardTemperature Board Temperature eNodeB None

BbuFan HPATemperature HPA Temperature eNodeB None

BbuFan OperateResult Operate Result eNodeB None

BbuFan ServiceType Service Type eNodeB None

BbuFan DEVTYPE DEVTYPE eNodeB None

BbuFan NeName Office Name eNodeB None

BbuFan SoftVer Software Version eNodeB None

BbuFan HardVer Hardware Version eNodeB None

BbuFan BtrmVer BootRom Version eNodeB None

BbuFan HwTestTime Test Time eNodeB None

BbuFan TestResult Test Result eNodeB None

Downlink
BbuFan DLFREQ eNodeB None
Frequency

BbuFan ULFREQ Uplink Frequency eNodeB None

EIU CN Cabinet No. eNodeB None

EIU SRN Subrack No. eNodeB None

EIU SN Slot No. eNodeB None

EIU AlarmState Alarm Status eNodeB None

EIU OpState Operational State eNodeB None

EIU AvailabilityStatus Availability Status eNodeB None

EIU Elabel Electronic Label eNodeB None

EIU BoardType Type eNodeB None

EIU BoardSerial Serial Number eNodeB None


EIU BoardDesc Description eNodeB None

Date of
EIU BoardManu eNodeB None
Manufacture

EIU BoardVendor Vendor eNodeB None

EIU BoardIssue Issue Number eNodeB None

EIU RuType Config Type eNodeB None

EIU ObjectNumber Object Number eNodeB None

EIU ObjectType Object Type eNodeB None

EIU BoardTemperature Board Temperature eNodeB None

EIU HPATemperature HPA Temperature eNodeB None

EIU OperateResult Operate Result eNodeB None

EIU ServiceType Service Type eNodeB None

EIU DEVTYPE DEVTYPE eNodeB None

EIU NeName Office Name eNodeB None

EIU SoftVer Software Version eNodeB None

EIU HardVer Hardware Version eNodeB None

EIU BtrmVer BootRom Version eNodeB None

EIU HwTestTime Test Time eNodeB None

EIU TestResult Test Result eNodeB None

Downlink
EIU DLFREQ eNodeB None
Frequency

EIU ULFREQ Uplink Frequency eNodeB None


MOD ENODEB
eNodeB ENODEBID eNodeB ID eNodeB DSP ENODEB
LST ENODEB
MOD ENODEB
eNodeB NAME eNodeB name eNodeB
LST ENODEB
Mobile country MOD ENODEB
eNodeB MCC eNodeB
code LST ENODEB
Mobile network MOD ENODEB
eNodeB MNC eNodeB
code LST ENODEB
MOD ENODEB
eNodeB ENBTYPE eNodeB type eNodeB
LST ENODEB
AUTOPOWEROFF Auto power control MOD ENODEB
eNodeB eNodeB
SWITCH switch LST ENODEB
MOD ENODEB
eNodeB POWEROFFTIME Auto power off time eNodeB
LST ENODEB
MOD ENODEB
eNodeB POWERONTIME Auto power on time eNodeB
LST ENODEB
MOD ENODEB
eNodeB LONGITUDE Longitude eNodeB
LST ENODEB
MOD ENODEB
eNodeB LATITUDE Latitude eNodeB
LST ENODEB
Electronic serial
eNodeB ElectriSerialNo eNodeB DSP ENODEB
number

eNodeB LicenseState LicenseState eNodeB DSP ENODEB

eNodeB
eNodeB AutoPoweroffStatus eNodeB DSP ENODEB
autopoweroff status
MOD ENODEB
eNodeB LOCATION Site Location eNodeB
LST ENODEB
Geo-coordinate MOD ENODEB
eNodeB GCDF eNodeB
data format LST ENODEB
LATITUDESECFOR Latitude with MOD ENODEB
eNodeB eNodeB
MAT second format LST ENODEB
LONGITUDESECF Longitude with MOD ENODEB
eNodeB eNodeB
ORMAT second format LST ENODEB
LST KPIALARM
KPIALARM KPITYPE KPITYPE eNodeB
MOD KPIALARM
MOD KPIALARM
KPIALARM REPORTSWITCH Report Switch eNodeB
LST KPIALARM
MOD KPIALARM
KPIALARM FLTTHRESHOLD FltThreshold eNodeB
LST KPIALARM
MOD KPIALARM
KPIALARM RESTHRESHOLD ResThreshold eNodeB
LST KPIALARM
MOD KPIALARM
KPIALARM MINCHECKTIMES MinCheckTimes eNodeB
LST KPIALARM
MOD KPIALARM
KPIALARM DETECTPERIOD DetectPeriod eNodeB
LST KPIALARM
DETECTBEGINTIM MOD KPIALARM
KPIALARM DetectBeginTime eNodeB
E LST KPIALARM
DETECTPERIODN MOD KPIALARM
KPIALARM DetectPeriodNum eNodeB
UM LST KPIALARM

PEU CN Cabinet No. eNodeB None


PEU SRN Subrack No. eNodeB None

PEU SN Slot No. eNodeB None

PEU AlarmState Alarm Status eNodeB None

PEU OpState Operational State eNodeB None

PEU AvailabilityStatus Availability Status eNodeB None

PEU Elabel Electronic Label eNodeB None

PEU BoardType Type eNodeB None

PEU BoardSerial Serial Number eNodeB None

PEU BoardDesc Description eNodeB None

Date of
PEU BoardManu eNodeB None
Manufacture

PEU BoardVendor Vendor eNodeB None

PEU BoardIssue Issue Number eNodeB None

PEU RuType Config Type eNodeB None

PEU ObjectNumber Object Number eNodeB None

PEU ObjectType Object Type eNodeB None

PEU BoardTemperature Board Temperature eNodeB None

PEU HPATemperature HPA Temperature eNodeB None

PEU OperateResult Operate Result eNodeB None

PEU ServiceType Service Type eNodeB None

PEU DEVTYPE DEVTYPE eNodeB None

PEU NeName Office Name eNodeB None

PEU SoftVer Software Version eNodeB None

PEU HardVer Hardware Version eNodeB None


PEU BtrmVer BootRom Version eNodeB None

PEU HwTestTime Test Time eNodeB None

PEU TestResult Test Result eNodeB None

Downlink
PEU DLFREQ eNodeB None
Frequency

PEU ULFREQ Uplink Frequency eNodeB None


DSP
ANTENNAPORT
LST
AntennaPort CN Cabinet No. eNodeB DSP
ANTENNAPORT
ANTENNAPORT
MOD
LST
ANTENNAPORT
AntennaPort SRN Subrack No. eNodeB DSP
ANTENNAPORT
ANTENNAPORT
MOD
LST
ANTENNAPORT
AntennaPort SN Slot No. eNodeB DSP
ANTENNAPORT
ANTENNAPORT
MOD
LST
ANTENNAPORT
AntennaPort PN Port No. eNodeB
ANTENNAPORT
MOD
MOD
Current Alarm ANTENNAPORT
ANTENNAPORT
AntennaPort THRESHOLDTYPE eNodeB
Threshold type LST
MOD
ANTENNAPORT
ANTENNAPORT
AntennaPort PWRSWITCH ALD Power Switch eNodeB
LST
MOD
ANTENNAPORT
Overcurrent alarm ANTENNAPORT
AntennaPort OCTHD eNodeB
clear threshold LST
MOD
ANTENNAPORT
Overcurrent alarm ANTENNAPORT
AntennaPort OOTHD eNodeB
occur threshold LST
MOD
ANTENNAPORT
Undercurrent alarm ANTENNAPORT
AntennaPort UCTHD eNodeB
clear threshold LST
MOD
ANTENNAPORT
Undercurrent alarm ANTENNAPORT
AntennaPort UOTHD eNodeB
occur threshold LST
MOD
ANTENNAPORT
ANTENNAPORT
AntennaPort FEEDERLENGTH Feeder length eNodeB
LST
MOD
ANTENNAPORT
TMA Downlink ANTENNAPORT
AntennaPort DLDELAY eNodeB
Delay LST
MOD
ANTENNAPORT
ANTENNAPORT
AntennaPort DUDELAY TMA Uplink Delay eNodeB
LST
ANTENNAPORT
DSP
AntennaPort ALDCurrValue ALD current value eNodeB
ANTENNAPORT
ALD Actual Power DSP
AntennaPort ALDRtmPwrSwitch eNodeB
Switch ANTENNAPORT
DSP CPRIPORT
LST CPRIPORT
CpriPort CN Cabinet No. eNodeB DSP
DSP CPRIPORT
RRUCHAINPHYTO
LST
PO CPRIPORT
CpriPort SRN Subrack No. eNodeB DSP
DSP CPRIPORT
RRUCHAINPHYTO
LST
PO CPRIPORT
CpriPort SN Slot No. eNodeB DSP
RRUCHAINPHYTO
PO
DSP CPRIPORT
LST CPRIPORT
CpriPort PN Port No. eNodeB DSP
RRUCHAINPHYTO
PO
CpriPort CpriRate Cpri line bit rate eNodeB DSP CPRIPORT

CpriPort AdmState Administrative state eNodeB DSP CPRIPORT

DSP RRU
RE ADMSTATE Administrative state eNodeB
LST RRU
ADD RRU
VSWR alarm post-
RE ALMPROCSW eNodeB MOD RRU
processing switch
LST RRU
VSWR alarm post- ADD RRU
ALMPROCTHRHL
RE processing eNodeB MOD RRU
D
threshold LST RRU
ADD RRU
VSWR alarm
RE ALMTHRHLD eNodeB MOD RRU
threshold
LST RRU
ADD RRU
RE PS RRU Position eNodeB
LST RRU
RRU Chain/Ring ADD RRU
RE RCN eNodeB
No. LST RRU
ADD RRU
DSP
RE TP RRU Topo Position eNodeB RRUCHAINPHYTO
PO
ADD RRU
LST RRU
RRU Work
RE RS eNodeB MOD RRU
Standard
LST RRU
ADD RRU
Number of RX MOD RRU
RE RXNUM eNodeB
channels DSP RRU
ADD RRU
LST RRU
Number of TX MOD RRU
RE TXNUM eNodeB
channels DSP RRU
LST RRU
CarrierNumPerRxBr Number of carriers
RE eNodeB DSP RRU
anch on the RX channel
CarrierNumPerTxBr Number of carriers
RE eNodeB DSP RRU
anch on the TX channel
Minimum UL
RE RxMinFreq eNodeB DSP RRU
frequency
Maximum UL
RE RxMaxFreq eNodeB DSP RRU
frequency
Minimum DL
RE TxMinFreq eNodeB DSP RRU
frequency
Maximum DL
RE TxMaxFreq eNodeB DSP RRU
frequency
Hardware maximum
MaxOutPwrPerBran
RE output power on the eNodeB DSP RRU
ch
TX channel
RE UlBranchGain UL channel gain eNodeB DSP RRU

Supported
RE UlBandwidth eNodeB DSP RRU
bandwidth

RE PATemperature PA Temperature eNodeB DSP RRU


DSP
RE Level Hop number eNodeB RRUCHAINPHYTO
PO
DSP
Physical RRU
RE DeviceSerialNo eNodeB RRUCHAINPHYTO
device serial No.
PO
DSP RRU
RRU stardard DSP
RE RatType eNodeB
capability RRUCHAINPHYTO
PO
RE AccessDirection Access Direction eNodeB DSP RRU

RE AlarmState Alarm Status eNodeB None

RE OpState Operational State eNodeB None

RE AvailabilityStatus Availability Status eNodeB None

RE Elabel Electronic Label eNodeB None

RE BoardType Type eNodeB None

RE BoardSerial Serial Number eNodeB None

RE BoardDesc Description eNodeB None

Date of
RE BoardManu eNodeB None
Manufacture

RE BoardVendor Vendor eNodeB None

RE BoardIssue Issue Number eNodeB None

RE RuType Config Type eNodeB None

RE ObjectNumber Object Number eNodeB None

RE ObjectType Object Type eNodeB None

RE BoardTemperature Board Temperature eNodeB None

RE HPATemperature HPA Temperature eNodeB None

RE OperateResult Operate Result eNodeB None

RE ServiceType Service Type eNodeB None

RE DEVTYPE DEVTYPE eNodeB None

RE NeName Office Name eNodeB None


RE SoftVer Software Version eNodeB None

RE HardVer Hardware Version eNodeB None

RE BtrmVer BootRom Version eNodeB None

RE HwTestTime Test Time eNodeB None

RE TestResult Test Result eNodeB None

Downlink
RE DLFREQ eNodeB None
Frequency

RE ULFREQ Uplink Frequency eNodeB None

RFU CN Cabinet No. eNodeB None

RFU SRN Subrack No. eNodeB None

RFU SN Slot No. eNodeB None

RFU RT RRU type eNodeB None

RFU ADMSTATE Administrative state eNodeB None

RFU AlarmState Alarm Status eNodeB None

RFU OpState Operational State eNodeB None

RFU AvailabilityStatus Availability Status eNodeB None

RFU Elabel Electronic Label eNodeB None

RFU BoardType Type eNodeB None

RFU BoardSerial Serial Number eNodeB None

RFU BoardDesc Description eNodeB None

Date of
RFU BoardManu eNodeB None
Manufacture

RFU BoardVendor Vendor eNodeB None

RFU BoardIssue Issue Number eNodeB None

RFU RuType Config Type eNodeB None


RFU ObjectNumber Object Number eNodeB None

RFU ObjectType Object Type eNodeB None

RFU BoardTemperature Board Temperature eNodeB None

RFU HPATemperature HPA Temperature eNodeB None

RFU OperateResult Operate Result eNodeB None

RFU ServiceType Service Type eNodeB None

RFU DEVTYPE DEVTYPE eNodeB None

VSWR alarm post-


RFU ALMPROCSW eNodeB None
processing switch
VSWR alarm post-
ALMPROCTHRHL
RFU processing eNodeB None
D
threshold
VSWR alarm
RFU ALMTHRHLD eNodeB None
threshold

RFU PS RRU Position eNodeB None

RRU Chain/Ring
RFU RCN eNodeB None
No.

RFU TP RRU Topo Position eNodeB None

RRU Work
RFU RS eNodeB None
Standard
Number of RX
RFU RXNUM eNodeB None
channels
Number of TX
RFU TXNUM eNodeB None
channels
CarrierNumPerRxBr Number of carriers
RFU eNodeB None
anch on the RX channel
CarrierNumPerTxBr Number of carriers
RFU eNodeB None
anch on the TX channel
Minimum UL
RFU RxMinFreq eNodeB None
frequency
Maximum UL
RFU RxMaxFreq eNodeB None
frequency
Minimum DL
RFU TxMinFreq eNodeB None
frequency
Maximum DL
RFU TxMaxFreq eNodeB None
frequency
Hardware maximum
MaxOutPwrPerBran
RFU output power on the eNodeB None
ch
TX channel
RFU UlBranchGain UL channel gain eNodeB None

Supported
RFU UlBandwidth eNodeB None
bandwidth

RFU PATemperature PA Temperature eNodeB None

RFU Level Hop number eNodeB None

Physical RRU
RFU DeviceSerialNo eNodeB None
device serial No.
RRU stardard
RFU RatType eNodeB None
capability

RFU AccessDirection Access Direction eNodeB None

RFU NeName Office Name eNodeB None

RFU SoftVer Software Version eNodeB None

RFU HardVer Hardware Version eNodeB None

RFU BtrmVer BootRom Version eNodeB None

RFU HwTestTime Test Time eNodeB None

RFU TestResult Test Result eNodeB None

Downlink
RFU DLFREQ eNodeB None
Frequency

RFU ULFREQ Uplink Frequency eNodeB None

RRU CN Cabinet No. eNodeB None

RRU SRN Subrack No. eNodeB None

RRU SN Slot No. eNodeB None


ADD RRU
RRU RN RRU Name eNodeB MOD RRU
LST RRU
RRU RT RRU type eNodeB None

RRU ADMSTATE Administrative state eNodeB None

RRU AlarmState Alarm Status eNodeB None

RRU OpState Operational State eNodeB None


RRU AvailabilityStatus Availability Status eNodeB None

RRU Elabel Electronic Label eNodeB None

RRU BoardType Type eNodeB None

RRU BoardSerial Serial Number eNodeB None

RRU BoardDesc Description eNodeB None

Date of
RRU BoardManu eNodeB None
Manufacture

RRU BoardVendor Vendor eNodeB None

RRU BoardIssue Issue Number eNodeB None

RRU RuType Config Type eNodeB None

RRU ObjectNumber Object Number eNodeB None

RRU ObjectType Object Type eNodeB None

RRU BoardTemperature Board Temperature eNodeB None

RRU HPATemperature HPA Temperature eNodeB None

RRU OperateResult Operate Result eNodeB None

RRU ServiceType Service Type eNodeB None

RRU DEVTYPE DEVTYPE eNodeB None

VSWR alarm post-


RRU ALMPROCSW eNodeB None
processing switch
VSWR alarm post-
ALMPROCTHRHL
RRU processing eNodeB None
D
threshold
VSWR alarm
RRU ALMTHRHLD eNodeB None
threshold

RRU PS RRU Position eNodeB None

RRU Chain/Ring
RRU RCN eNodeB None
No.

RRU TP RRU Topo Position eNodeB None

RRU Work
RRU RS eNodeB None
Standard
Number of RX
RRU RXNUM eNodeB None
channels
Number of TX
RRU TXNUM eNodeB None
channels
CarrierNumPerRxBr Number of carriers
RRU eNodeB None
anch on the RX channel
CarrierNumPerTxBr Number of carriers
RRU eNodeB None
anch on the TX channel
Minimum UL
RRU RxMinFreq eNodeB None
frequency
Maximum UL
RRU RxMaxFreq eNodeB None
frequency
Minimum DL
RRU TxMinFreq eNodeB None
frequency
Maximum DL
RRU TxMaxFreq eNodeB None
frequency
Hardware maximum
MaxOutPwrPerBran
RRU output power on the eNodeB None
ch
TX channel
RRU UlBranchGain UL channel gain eNodeB None

Supported
RRU UlBandwidth eNodeB None
bandwidth

RRU PATemperature PA Temperature eNodeB None

RRU Level Hop number eNodeB None

Physical RRU
RRU DeviceSerialNo eNodeB None
device serial No.
RRU stardard
RRU RatType eNodeB None
capability

RRU AccessDirection Access Direction eNodeB None

RRU NeName Office Name eNodeB None

RRU SoftVer Software Version eNodeB None

RRU HardVer Hardware Version eNodeB None

RRU BtrmVer BootRom Version eNodeB None

RRU HwTestTime Test Time eNodeB None

RRU TestResult Test Result eNodeB None

Downlink
RRU DLFREQ eNodeB None
Frequency
RRU ULFREQ Uplink Frequency eNodeB None
ADD RRUCHAIN
DSP RRUCHAIN
RRU Chain/Ring
RRUCHAIN RCN eNodeB LST RRUCHAIN
ADD RRUCHAIN
No.
MOD
MOD RRUCHAIN
RRUCHAIN
RMV
DSP RRUCHAIN
RRUCHAIN TT Topo Type eNodeB
RRUCHAINPHYTO
PO
ADD RRUCHAIN
RRUCHAIN BM Backup Mode eNodeB LST
MODRRUCHAIN
ADD RRUCHAIN
RRUCHAIN
LST
MODRRUCHAIN
RRUCHAIN
DSP
RRUCHAIN HCN Head Cabinet No. eNodeB ADD RRUCHAIN
RRUCHAINPHYTO
MOD
PO RRUCHAIN
DSP
LST RRUCHAIN
RRUCHAIN HSRN Head Subrack No. eNodeB ADD RRUCHAIN
RRUCHAINPHYTO
MOD
PO RRUCHAIN
DSP
LST RRUCHAIN
RRUCHAIN HSN Head Slot No. eNodeB ADD RRUCHAIN
RRUCHAINPHYTO
MOD
PO RRUCHAIN
DSP
LST RRUCHAIN
RRUCHAIN HPN Head Port No. eNodeB ADD RRUCHAIN
RRUCHAINPHYTO
MOD
PO RRUCHAIN
DSP
LST RRUCHAIN
RRUCHAIN TCN Tail Cabinet No. eNodeB ADD RRUCHAIN
RRUCHAINPHYTO
MOD
PO RRUCHAIN
DSP
LST RRUCHAIN
RRUCHAIN TSRN Tail Subrack No. eNodeB ADD RRUCHAIN
RRUCHAINPHYTO
MOD
PO RRUCHAIN
DSP
LST RRUCHAIN
RRUCHAIN TSN Tail Slot No. eNodeB ADD RRUCHAIN
RRUCHAINPHYTO
MOD
PO RRUCHAIN
DSP
LST RRUCHAIN
RRUCHAIN TPN Tail Port No. eNodeB
RRUCHAINPHYTO
PO
BreakPoint position MOD RRUCHAIN
LST RRUCHAIN
RRUCHAIN BRKPOS1 eNodeB
1 LST RRUCHAIN
BreakPoint position MOD RRUCHAIN
RRUCHAIN BRKPOS2 eNodeB
2 LST RRUCHAIN
ADD RRUCHAIN
RRUCHAIN AT Access Type eNodeB
LST RRUCHAIN

RRUCHAIN ChainLevel Chain/Ring Level eNodeB DSP RRUCHAIN

RRUCHAIN RRUNum RRU Number eNodeB DSP RRUCHAIN


DSP RXBRANCH
RxBranch CN Cabinet No. eNodeB LST RXBRANCH
MOD RXBRANCH
DSP RXBRANCH
RxBranch SRN Subrack No. eNodeB LST RXBRANCH
MOD RXBRANCH
DSP RXBRANCH
RxBranch SN Slot No. eNodeB LST RXBRANCH
MOD RXBRANCH
DSP RXBRANCH
RxBranch RXNO RX channel No. eNodeB LST RXBRANCH
MOD RXBRANCH
Logical switch of MOD RXBRANCH
RxBranch RXSW eNodeB
RX channel LST RXBRANCH
Rx Channel MOD RXBRANCH
RxBranch ATTEN eNodeB
Attenuation LST RXBRANCH
RxBranch PhyStatus Physical status eNodeB DSP
ADD RXBRANCH
SECTOR
DSP SECTOR
LST SECTOR
Sector SECN Sector No. eNodeB
MOD RETTILT
MOD SECTOR
ADD SECTOR
Sector LONGITUDE Longitude eNodeB RMV SECTOR
MOD SECTOR
LST SECTOR
ADD SECTOR
Sector LATITUDE Latitude eNodeB MOD SECTOR
LST SECTOR
ADD SECTOR
Sector ANTM Antenna mode eNodeB MOD SECTOR
Cabinet No. of the LST SECTOR
ADD SECTOR
RRU where
Sector CN1 eNodeB MOD SECTOR
antenna port 1 is
Subrack LST SECTOR
located No. of the ADD SECTOR
RRU where
Sector SRN1 eNodeB MOD SECTOR
antenna port 1 is
LST SECTOR
located
Slot No. of the RRU ADD SECTOR
Sector SN1 where antenna port eNodeB MOD SECTOR
1 is located LST SECTOR
ADD SECTOR
Port No. of antenna
Sector PN1 eNodeB MOD SECTOR
connector 1
Cabinet No. of the LST SECTOR
ADD SECTOR
RRU where
Sector CN2 eNodeB MOD SECTOR
antenna port 2 is
Subrack LST SECTOR
located No. of the ADD SECTOR
RRU where
Sector SRN2 eNodeB MOD SECTOR
antenna port 2 is
LST SECTOR
located
Slot No. of the RRU ADD SECTOR
Sector SN2 where antenna port eNodeB MOD SECTOR
2 is located LST SECTOR
ADD SECTOR
Port No. of antenna
Sector PN2 eNodeB MOD SECTOR
connector 2
Cabinet No. of the LST SECTOR
ADD SECTOR
RRU where
Sector CN3 eNodeB MOD SECTOR
antenna port 3 is
Subrack LST SECTOR
located No. of the ADD SECTOR
RRU where
Sector SRN3 eNodeB MOD SECTOR
antenna port 3 is
LST SECTOR
located
Slot No. of the RRU ADD SECTOR
Sector SN3 where antenna port eNodeB MOD SECTOR
3 is located LST SECTOR
ADD SECTOR
Port No. of antenna
Sector PN3 eNodeB MOD SECTOR
connector 3
Cabinet No. of the LST SECTOR
ADD SECTOR
RRU where
Sector CN4 eNodeB MOD SECTOR
antenna port 4 is
Subrack LST SECTOR
located No. of the ADD SECTOR
RRU where
Sector SRN4 eNodeB MOD SECTOR
antenna port 4 is
LST SECTOR
located
Slot No. of the RRU ADD SECTOR
Sector SN4 where antenna port eNodeB MOD SECTOR
4 is located LST SECTOR
ADD SECTOR
Port No. of antenna
Sector PN4 eNodeB MOD SECTOR
connector 4
Cabinet No. of the LST SECTOR
ADD SECTOR
RRU where
Sector CN5 eNodeB MOD SECTOR
antenna port 5 is
Subrack LST SECTOR
located No. of the ADD SECTOR
RRU where
Sector SRN5 eNodeB MOD SECTOR
antenna port 5 is
LST SECTOR
located
Slot No. of the RRU ADD SECTOR
Sector SN5 where antenna port eNodeB MOD SECTOR
5 is located LST SECTOR
ADD SECTOR
Port No. of antenna
Sector PN5 eNodeB MOD SECTOR
connector 5
Cabinet No. of the LST SECTOR
ADD SECTOR
RRU where
Sector CN6 eNodeB MOD SECTOR
antenna port 6 is
Subrack LST SECTOR
located No. of the ADD SECTOR
RRU where
Sector SRN6 eNodeB MOD SECTOR
antenna port 6 is
LST SECTOR
located
Slot No. of the RRU ADD SECTOR
Sector SN6 where antenna port eNodeB MOD SECTOR
6 is located LST SECTOR
ADD SECTOR
Port No. of antenna
Sector PN6 eNodeB MOD SECTOR
connector 6
Cabinet No. of the LST SECTOR
ADD SECTOR
RRU where
Sector CN7 eNodeB MOD SECTOR
antenna port 7 is
Subrack LST SECTOR
located No. of the ADD SECTOR
RRU where
Sector SRN7 eNodeB MOD SECTOR
antenna port 7 is
LST SECTOR
located
Slot No. of the RRU ADD SECTOR
Sector SN7 where antenna port eNodeB MOD SECTOR
7 is located LST SECTOR
ADD SECTOR
Port No. of antenna
Sector PN7 eNodeB MOD SECTOR
connector 7
Cabinet No. of the LST SECTOR
ADD SECTOR
RRU where
Sector CN8 eNodeB MOD SECTOR
antenna port 8 is
Subrack LST SECTOR
located No. of the ADD SECTOR
RRU where
Sector SRN8 eNodeB MOD SECTOR
antenna port 8 is
LST SECTOR
located
Slot No. of the RRU ADD SECTOR
Sector SN8 where antenna port eNodeB MOD SECTOR
8 is located LST SECTOR
ADD SECTOR
Port No. of antenna
Sector PN8 eNodeB MOD SECTOR
connector 8
LST SECTOR
ADD SECTOR
Sector SECM Sector mode eNodeB MOD SECTOR
LST SECTOR
ADD SECTOR
Sector SECTORNAME Sector name eNodeB MOD SECTOR
LST SECTOR
ADD SECTOR
Sector ALTITUDE Altitude eNodeB MOD SECTOR
LST SECTOR
ADD SECTOR
UNCERTSEMIMAJ
Sector UncertSemiMajor eNodeB MOD SECTOR
OR
LST SECTOR
ADD SECTOR
UNCERTSEMIMIN
Sector UncertSemiMinor eNodeB MOD SECTOR
OR
LST SECTOR
ADD SECTOR
ORIENTOFMAJOR
Sector OrientOfMajorAxis eNodeB MOD SECTOR
AXIS
LST SECTOR
ADD SECTOR
Sector UNCERTALTITUDE UncertAltitude eNodeB MOD SECTOR
LST SECTOR
ADD SECTOR
Sector CONFIDENCE Confidence eNodeB MOD SECTOR
LST SECTOR
ADD SECTOR
Sector COMBM CombMode eNodeB MOD SECTOR
LST SECTOR
ADD SECTOR
Geo-coordinate
Sector GCDF eNodeB MOD SECTOR
data format
LST SECTOR
ADD SECTOR
ANTLATITUDESEC Antenna latitude
Sector eNodeB MOD SECTOR
FORMAT with second format
LST SECTOR
ADD SECTOR
ANTLONGITUDES Antenna longitude
Sector eNodeB MOD SECTOR
ECFORMAT with second format
LST SECTOR
ADD SECTOR
Sector OMNIFLAG Omni Mode eNodeB MOD SECTOR
LST SECTOR
Maximum power of
Sector MaxTxPower eNodeB DSP SECTOR
the cell

Sector LicState License state eNodeB DSP SECTOR

RXFrequencyRang RX Frequency
Sector eNodeB DSP SECTOR
e Range
TXFrequencyRang TX Frequency
Sector eNodeB DSP SECTOR
e Range
DSP SFP
SFP CN Cabinet No. eNodeB
LST SFP
DSP SFP
SFP SRN Subrack No. eNodeB
LST SFP
DSP SFP
SFP SN Slot No. eNodeB
LST SFP
SFP module DSP SFP
SFP MODULEID eNodeB
number LST SFP

SFP InstallStatus Installed status eNodeB DSP SFP

SFP SfpType SFP module type eNodeB DSP SFP

SFP VendorName Manufacturer name eNodeB DSP SFP

SFP TransMode Transmission Mode eNodeB DSP SFP

SFP WaveLength Wavelength eNodeB DSP SFP

Transmission code
SFP Rating eNodeB DSP SFP
rate
Transmission
distance of single-
SFP LinkLength0 mode fiber (9- eNodeB DSP SFP
Transmission
micrometer core
distance
diameter)of single-
SFP LinkLength1 mode fiber (9- eNodeB DSP SFP
Transmission
micrometer core
distance
diameter)of multi-
SFP LinkLength2 mode fiber (50- eNodeB DSP SFP
Transmission
micrometer core
distance
diameter)of multi-
SFP LinkLength3 mode fiber (62.5- eNodeB DSP SFP
micrometer core
diameter)
SFP Temperature Temperature eNodeB DSP SFP
SFP Voltage Voltage eNodeB DSP SFP

SFP Current Current eNodeB DSP SFP

SFP OutputPower TX optical power eNodeB DSP SFP

SFP InputPower RX optical power eNodeB DSP SFP


Transmission
CopperCableLengt DSP
SFP distance of copper eNodeB DSP TXBRANCH
SFP
h DSP VSWR
cable
LOC RRUTC
TxBranch CN Cabinet No. eNodeB DSP TXBRANCH
LST TXBRANCH
DSP
MODVSWR
TXBRANCH
LOC
STR RRUTC
VSWRTEST
TxBranch SRN Subrack No. eNodeB DSP
LST TXBRANCH
TXBRANCH
VER
DSP TXPOWER
MODVSWR
TXBRANCH
LOC
STR RRUTC
VSWRTEST
TxBranch SN Slot No. eNodeB DSP
LST TXBRANCH
TXBRANCH
VER
DSP TXPOWER
VSWR
MOD TXBRANCH
LOC RRUTC
STR VSWRTEST
TxBranch TXNO TX channel No. eNodeB LST
VERTXBRANCH
TXPOWER
MOD TXBRANCH
Logical switch of TX STR VSWRTEST
MOD TXBRANCH
TxBranch TXSW eNodeB VERTXBRANCH
TXPOWER
channel LST
DSP TXBRANCH
TxBranch Vswr VSWR eNodeB DSP VSWR
STR VSWRTEST
TxBranch PhyStatus Physical status eNodeB DSP TXBRANCH

TxBranch VswrPos VSWR POSITION eNodeB None


Maximum Output
TxBranch MaxOutputPower Power of the TX eNodeB DSP TXBRANCH
Channel ADD BITS
DSP BITS
BITS BN BITS Clock No. eNodeB MOD BITS
RMV BITS
LST BITS
ADD BITS
BITS CN Cabinet No. eNodeB
LST BITS
ADD BITS
BITS SRN Subrack No. eNodeB
LST BITS
ADD BITS
BITS SN Slot No. eNodeB
LST BITS

BITS ActiveState Link Active State eNodeB DSP BITS

BITS AvailableState Link Available State eNodeB DSP BITS


ADD BITS
BITS PRI Priority eNodeB MOD BITS
ADD LINECLK
LST BITS
DSP LINECLK
LineClk LN Line Clock No. eNodeB MOD LINECLK
RMV LINECLK
LST
ADDLINECLK
LINECLK
LineClk CN Cabinet No. eNodeB
LST LINECLK
ADD LINECLK
LineClk SRN Subrack No. eNodeB
LST LINECLK
ADD LINECLK
LineClk SN Slot No. eNodeB
LST LINECLK
ADD LINECLK
LineClk PN Port No. eNodeB DSP LINECLK
LST LINECLK
LineClk ActiveState Link Active State eNodeB DSP LINECLK

LineClk AvailableState Link Available State eNodeB DSP LINECLK


ADD LINECLK
LineClk PRI Priority eNodeB MOD LINECLK
LST
ADDLINECLK
PEERCLK
DSP PEERCLK
PeerClk PN Peer Clock No. eNodeB
RMV PEERCLK
LST PEERCLK
PeerClk ActiveState Link Active State eNodeB DSP PEERCLK

PeerClk AvailableState Link Available State eNodeB DSP PEERCLK


ADD TOD
DSP TOD
TOD TN TOD Clock No. eNodeB MOD TOD
RMV TOD
ADD TOD
LST TOD
TOD TYPE TOD Type eNodeB DSP TOD
LST TOD
ADD TOD
TOD CN Cabinet No. eNodeB
LST TOD
ADD TOD
TOD SRN Subrack No. eNodeB
LST TOD
ADD TOD
TOD SN Slot No. eNodeB
LST TOD
ADD TOD
TOD CABLETYPE Cable Type eNodeB MOD TOD
LST TOD
ADD TOD
TOD CABLE_LEN Cable Length eNodeB MOD TOD
LST TOD
TOD ActiveState Link Active State eNodeB DSP TOD

TOD AvailableState Link Available State eNodeB DSP TOD

TOD DELAY Delay eNodeB DSP TOD


ADD TOD
TOD PRI Priority eNodeB MOD GPS
ADD TOD
LST
DSP TOD
GPS
MOD GPS
GPS GN GPS Clock No. eNodeB
RMV GPS
RST SATCARD
ADD GPS
LST GPS
GPS CN Cabinet No. eNodeB
LST GPS
ADD GPS
GPS SRN Subrack No. eNodeB
LST GPS
ADD GPS
GPS SN Slot No. eNodeB
LST GPS
MOD GPSPOS
GPS WPOS Way to Get Position eNodeB
LST GPSPOS
MOD GPSPOS
GPS LONG Antenna Longitude eNodeB DSP GPS
LST GPSPOS
MOD GPSPOS
GPS LAT Antenna Latitude eNodeB DSP GPS
LST GPSPOS
MOD GPSPOS
GPS ALT Antenna Altitude eNodeB DSP GPS
LST GPSPOS
MOD GPSPOS
GPS AGL Antenna Angle eNodeB DSP GPS
LST GPSPOS
GPS DELAY Feeder Delay eNodeB DSP GPS

MOD GPSPOS
GPS DURATION Duration eNodeB
LST GPSPOS
MOD GPSPOS
GPS PRECISION Precision eNodeB
LST GPSPOS
ADD GPS
GPS CABLETYPE Cable Type eNodeB MOD GPS
LST GPS
ADD GPS
GPS CABLE_LEN Cable Length eNodeB MOD GPS
LST GPS
GPS PosFix GPS Position Fixed eNodeB DSP GPS

GPS Almnac Almanac Validity eNodeB DSP GPS

GPS PosSolu Position Solution eNodeB DSP GPS

GPS FixPos Fixed Position eNodeB DSP GPS

GPS ClkSteer Clock Steering eNodeB DSP GPS

GPS ClkMode Clock Model Validity eNodeB DSP GPS

GLONASS
GPS GlonassNum eNodeB DSP GPS
Satellites Traced

GPS GpsCardState GPS Card State eNodeB DSP GPS

GPS GpsCardType GPS Card Type eNodeB DSP GPS

GPS Satellites
GPS GpsNum eNodeB DSP GPS
Traced
ADD GPS
MOD GPS
GPS MODE GPS Work Mode eNodeB
DSP GPS
LST GPS
COMPASS
GPS CompassNum eNodeB DSP GPS
Satellites Traced
GPS ActiveState Link Active State eNodeB DSP GPS
ADD
ADD IPCLKLINK
GPS
GPS PRI Priority eNodeB DSP
MODIPCLKLINK
GPS
DSP PRICLASS
LST GPS
RMV IPCLKLINK
IPCLKLNK LN IP Clock No. eNodeB SET
CLASSIDENTIFY
SET PRICLASS
ADD IPCLKLINK
IPCLKLNK ICPT Protocol Type eNodeB LST IPCLKLINK
IPCLKLINK
LST
LST PRICLASS
ADD IPCLKLINK
IPCLKLNK CN Cabinet No. eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK SRN Subrack No. eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK SN Slot No. eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK CIP Client IP eNodeB DSP IPCLKLINK
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK SIP Server IP eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK DM Domain eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK DELAYTYPE Delay Type eNodeB
LST IPCLKLINK
SET
Priority Clock Class
IPCLKLNK CLASSIDENTIFY eNodeB CLASSIDENTIFY
Identify Flag
DSP PRICLASS
SET PRICLASS
Priority Clock
IPCLKLNK CLASS0 eNodeB DSP PRICLASS
Class0
LST PRICLASS
SET PRICLASS
Priority Clock
IPCLKLNK CLASS1 eNodeB DSP PRICLASS
Class1
LST PRICLASS
SET PRICLASS
Priority Clock
IPCLKLNK CLASS2 eNodeB DSP PRICLASS
Class2
LST PRICLASS
SET PRICLASS
Priority Clock
IPCLKLNK CLASS3 eNodeB DSP PRICLASS
Class3
LST PRICLASS
Current Priority
IPCLKLNK CurClass eNodeB DSP PRICLASS
Clock Class

IPCLKLNK ActiveState Link Active State eNodeB DSP IPCLKLINK

IPCLKLNK AvailableState Link Available State eNodeB DSP IPCLKLINK

ADD IPCLKLINK
IPCLKLNK CNM Clock Net Mode eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK CMPST Compensation eNodeB
LST IPCLKLINK

IPCLKLNK StepMode Step Mode eNodeB DSP IPCLKLINK

IPCLKLNK VlanId VLAN ID eNodeB DSP IPCLKLINK


IPCLKLNK UtcOffset UTC Offset eNodeB None

ADD IPCLKLINK
IPCLKLNK PRI Priority eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK ANNFREQ Announce Freq eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK SYNCFREQ Sync Freq eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK MASTERPRIO Master Priority eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK PROFILETYPE Profile Type eNodeB
LST IPCLKLINK
ADD IPCLKLINK
IPCLKLNK NEGDURATION Negotiate Duration eNodeB
LST IPCLKLINK
ADD SYNCETH
DSP SYNCETH
SyncEth LN SyncEth Clock No. eNodeB MOD SYNCETH
RMV SYNCETH
LST
ADDSYNCETH
SYNCETH
SyncEth CN Cabinet No. eNodeB
LST SYNCETH
ADD SYNCETH
SyncEth SRN Subrack No. eNodeB
LST SYNCETH
ADD SYNCETH
SyncEth SN Slot No. eNodeB
LST SYNCETH
ADD SYNCETH
SyncEth PN Port No. eNodeB
LST SYNCETH
ADD SYNCETH
MOD SYNCETH
SyncEth SSM SSM Selection eNodeB
DSP SYNCETH
LST SYNCETH
SyncEth ActiveState Link Active State eNodeB DSP SYNCETH

SyncEth AvailableState Link Available State eNodeB DSP SYNCETH


ADD SYNCETH
SyncEth PRI Priority eNodeB MOD SYNCETH
LST SYNCETH
Tasm AvailableState Clock Source State eNodeB DSP CLKSRC

Tasm LicenseAuthorized License Authorized eNodeB DSP CLKSRC

Clock Source
Tasm PRI eNodeB DSP CLKSRC
Priority
SET CLKMODE
Tasm SRCNO Clock Source No. eNodeB DSP CLKSRC
LST CLKMODE
Selected Clock SET CLKMODE
Tasm CLKSRC eNodeB
Source LST CLKMODE
SET CLKMODE
Clock Working
Tasm MODE eNodeB DSP CLKSTAT
Mode SET
LST CLKMODE
Clock CLKSYNCMODE
Tasm CLKSYNCMODE Synchronization eNodeB DSP CLKSTAT
Mode LST
CLKSYNCMODE
Current Clock
Tasm CurrentSrcStatus eNodeB DSP CLKSTAT
Source State

Tasm PllStatus PLL Status eNodeB DSP CLKSTAT

Current Clock
Tasm CurrentSrc eNodeB DSP CLKSTAT
Source
SET LOCALCLKQL
Tasm QL Quality Level eNodeB DSP SYNCETH
LST LOCALCLKQL
DSP CPRILBR
CPRILBR RCN RRU Chain No. eNodeB
STR CPRILBRNEG
Current head line
CPRILBR CURLBR eNodeB DSP CPRILBR
bit rate
Current head
CPRILBR CURNEGSTAT eNodeB DSP CPRILBR
negotiation status
Current tail line bit
CPRILBR CURTAILLBR eNodeB DSP CPRILBR
rate
Current tail
CPRILBR CURTAILNEGSTAT eNodeB DSP CPRILBR
negotiation status

CPRILBR CN Cabinet No. eNodeB DSP CPRILBR

CPRILBR SRN Subrack No. eNodeB DSP CPRILBR

CPRILBR SN Slot No. eNodeB DSP CPRILBR

CPRILBR NODE Node eNodeB DSP CPRILBR

CPRILBR MAXBR Max bit rate eNodeB DSP CPRILBR


Energy
SET ECMP
ENERGYCON MP Consumption eNodeB
LST ECMP
Measurement Point
PSU Intelligent SET PSUISS
PSUIS PSUISS eNodeB
Shutdown Switch LST
ADDPSUISS
CABINET
DSP CABMFRINFO
Cabinet CN Cabinet No. eNodeB LST CABINET
MOD CABINET
ADD
RMV CABINET
CABINET
Cabinet TYPE Cabinet Type eNodeB MOD CABINET
LST CABINET
ADD CABINET
Cabinet DESC Cabinet Description eNodeB MOD CABINET
LST CABINET
Cabinet CabinetType Model eNodeB DSP CABMFRINFO
ADD SUBRACK
LST SUBRACK
Subrack CN Cabinet No. eNodeB
MOD SUBRACK
ADD
RMV SUBRACK
SUBRACK
LST SUBRACK
Subrack SRN Subrack No. eNodeB
MOD SUBRACK
RMV SUBRACK
ADD SUBRACK
Subrack TYPE Subrack Type eNodeB
LST SUBRACK
ADD SUBRACK
Subrack DESC Subrack Description eNodeB MOD SUBRACK
LST SUBRACK
Subrack PWRTYPE Power Type eNodeB None

RU AlarmState Alarm Status eNodeB DSP BRD

DSP BRD
RU OpState Operational State eNodeB
DSP RRU
DSP BRD
RU AvailabilityStatus Availability Status eNodeB
DSP RRU

RU Elabel Electronic Label eNodeB None

DSP
RU BoardType Type eNodeB
BRDMFRINFO
DSP
BRDMFRINFO
RU BoardSerial Serial Number eNodeB DSP CABMFRINFO
DSP
DSP
BRDMFRINFO
HWTSTRESULT
RU BoardDesc Description eNodeB DSP CABMFRINFO
DSP
DSP
HWTSTRESULT
Date of
RU BoardManu eNodeB BRDMFRINFO
Manufacture
DSP CABMFRINFO
DSP
RU BoardVendor Vendor eNodeB BRDMFRINFO
DSP CABMFRINFO
DSP
RU BoardIssue Issue Number eNodeB
BRDMFRINFO

RU RuType Config Type eNodeB None

RU ObjectNumber Object Number eNodeB None

RU ObjectType Object Type eNodeB None

RU BoardTemperature Board Temperature eNodeB None

RU HPATemperature HPA Temperature eNodeB None

RU OperateResult Operate Result eNodeB None

RU ServiceType Service Type eNodeB None

RU DEVTYPE DEVTYPE eNodeB None

DSP
RU NeName Office Name eNodeB
HWTSTRESULT
DSP
RU SoftVer Software Version eNodeB
HWTSTRESULT
DSP
RU HardVer Hardware Version eNodeB
HWTSTRESULT
DSP
RU BtrmVer BootRom Version eNodeB
HWTSTRESULT
DSP
RU HwTestTime Test Time eNodeB
HWTSTRESULT
DSP
RU TestResult Test Result eNodeB
HWTSTRESULT
Downlink
RU DLFREQ eNodeB STR HWTST
Frequency

RU ULFREQ Uplink Frequency eNodeB STR


ADD HWTST
EMU
CLR EMUALM
DSP EMU
EMU CN Cabinet No. eNodeB ADD EMU
LST EMU
CLR EMUALM
MOD EMU
DSP
RMV EMU
EMU
EMU SRN Subrack No. eNodeB ADD EMU
LST EMU
CLR EMUALM
MOD EMU
DSP
RMV EMU
EMU
EMU SN Slot No. eNodeB
LST EMU
MOD EMU
Manager Cabinet ADD
RMV EMU
EMU
EMU MCN eNodeB
No. LST EMU
Manager Subrack ADD EMU
EMU MSRN eNodeB
No. LST EMU
ADD EMU
EMU MPN Manager Port No. eNodeB MOD EMU
LST EMU
ADD EMU
EMU ADDR Address eNodeB MOD EMU
LST EMU
ADD EMU
Temperature Alarm
EMU TLTHD eNodeB MOD EMU
Lower Threshold
LST EMU
ADD EMU
Temperature Alarm
EMU TUTHD eNodeB MOD EMU
Upper Threshold
LST EMU
ADD EMU
Humidity Alarm
EMU HLTHD eNodeB MOD EMU
Lower Threshold
LST EMU
ADD EMU
Humidity Alarm
EMU HUTHD eNodeB MOD EMU
Upper Threshold
LST EMU
ADD EMU
Special Analog
EMU SAAF eNodeB MOD EMU
Alarm Flag
LST EMU
ADD EMU
Special Boolean
EMU SBAF eNodeB MOD EMU
Alarm Flag
LST EMU
Ambient
EMU Temperature eNodeB DSP EMU
Temperature

EMU Humidity Ambient Humidity eNodeB DSP EMU

EMU Invol48 -48V Input Voltage eNodeB DSP EMU

Analog Port 1
EMU Anain1 eNodeB DSP EMU
Measurement Value
Analog Port 2
EMU Anain2 eNodeB DSP EMU
Measurement Value
Analog Port 3
EMU Anain3 eNodeB DSP EMU
Measurement Value
Analog Port 4
EMU Anain4 eNodeB DSP EMU
Measurement Value

EMU AlarmState Alarm Status eNodeB None

EMU OpState Operational State eNodeB None

EMU AvailabilityStatus Availability Status eNodeB None

EMU Elabel Electronic Label eNodeB None

EMU BoardType Type eNodeB None

EMU BoardSerial Serial Number eNodeB None

EMU BoardDesc Description eNodeB None

Date of
EMU BoardManu eNodeB None
Manufacture

EMU BoardVendor Vendor eNodeB None

EMU BoardIssue Issue Number eNodeB None

EMU RuType Config Type eNodeB None

EMU ObjectNumber Object Number eNodeB None

EMU ObjectType Object Type eNodeB None

EMU BoardTemperature Board Temperature eNodeB None

EMU HPATemperature HPA Temperature eNodeB None

EMU OperateResult Operate Result eNodeB None

EMU ServiceType Service Type eNodeB None

EMU DEVTYPE DEVTYPE eNodeB None

EMU NeName Office Name eNodeB None

EMU SoftVer Software Version eNodeB None

EMU HardVer Hardware Version eNodeB None


EMU BtrmVer BootRom Version eNodeB None

EMU HwTestTime Test Time eNodeB None

EMU TestResult Test Result eNodeB None

Downlink
EMU DLFREQ eNodeB None
Frequency

EMU ULFREQ Uplink Frequency eNodeB None


ADD FMU
CLR FMUALM
DSP FMU
FMU CN Cabinet No. eNodeB ADD FMU
LST FMU
CLR FMUALM
MOD FMU
DSP
RMV FMU
FMU
FMU SRN Subrack No. eNodeB ADD FMU
LST FMU
CLR FMUALM
MOD FMU
DSP
RMV FMU
FMU
FMU SN Slot No. eNodeB
LST FMU
MOD FMU
ADD FMU
Manager Cabinet RMV FMU
FMU MCN eNodeB MOD FMU
No.
LST FMU
ADD FMU
Manager Subrack
FMU MSRN eNodeB MOD FMU
No.
LST FMU
ADD FMU
FMU MPN Manager Port No. eNodeB MOD FMU
LST FMU
ADD FMU
FMU ADDR Address eNodeB MOD FMU
LST FMU
ADD FMU
Special Boolean
FMU SBAF eNodeB MOD FMU
Alarm Flag
LST FMU
FMU SpeedRate Fan Speed Rate eNodeB DSP FMU

Temperature at Fan
FMU TempOut eNodeB DSP FMU
Air Outlet
Temperature at Fan
FMU TempIn eNodeB DSP FMU
Air Inlet

FMU AverageSpeed Fan Average Speed eNodeB DSP FMU


ADD FMU
Smart Temperature
FMU STC eNodeB MOD FMU
Control
LST FMU
FMU AlarmState Alarm Status eNodeB None

FMU OpState Operational State eNodeB None

FMU AvailabilityStatus Availability Status eNodeB None

FMU Elabel Electronic Label eNodeB None

FMU BoardType Type eNodeB None


FMU BoardSerial Serial Number eNodeB None

FMU BoardDesc Description eNodeB None

Date of
FMU BoardManu eNodeB None
Manufacture

FMU BoardVendor Vendor eNodeB None

FMU BoardIssue Issue Number eNodeB None

FMU RuType Config Type eNodeB None

FMU ObjectNumber Object Number eNodeB None

FMU ObjectType Object Type eNodeB None

FMU BoardTemperature Board Temperature eNodeB None

FMU HPATemperature HPA Temperature eNodeB None

FMU OperateResult Operate Result eNodeB None

FMU ServiceType Service Type eNodeB None

FMU DEVTYPE DEVTYPE eNodeB None

FMU NeName Office Name eNodeB None

FMU SoftVer Software Version eNodeB None

FMU HardVer Hardware Version eNodeB None

FMU BtrmVer BootRom Version eNodeB None

FMU HwTestTime Test Time eNodeB None

FMU TestResult Test Result eNodeB None

Downlink
FMU DLFREQ eNodeB None
Frequency

FMU ULFREQ Uplink Frequency eNodeB None


ADD TCU
CLR TCUALM
DSP TCU
TCU CN Cabinet No. eNodeB ADD TCU
LST TCU
CLR TCUALM
MOD TCU
DSP
RMV TCU
TCU
TCU SRN Subrack No. eNodeB
LST TCU
MOD TCU
RMV TCU
ADD TCU
CLR TCUALM
DSP TCU
TCU SN Slot No. eNodeB
LST TCU
MOD TCU
Manager Cabinet ADD
RMV TCU
TCU
TCU MCN eNodeB
No. LST TCU
Manager Subrack ADD TCU
TCU MSRN eNodeB
No. LST TCU
ADD TCU
TCU MPN Manager Port No. eNodeB MOD TCU
LST TCU
ADD TCU
TCU ADDR Address eNodeB MOD TCU
LST TCU
ADD TCU
Temperature Alarm
TCU TLTHD eNodeB MOD TCU
Lower Threshold
LST TCU
ADD TCU
Temperature Alarm
TCU TUTHD eNodeB MOD TCU
Upper Threshold
LST TCU
ADD TCU
Special Boolean
TCU SBAF eNodeB MOD TCU
Alarm Flag
LST TCU
ADD TCU
TCU HEATERNUM Heater Number eNodeB MOD TCU
LST TCU
ADD TCU
TCU LNMODE Low Noise Mode eNodeB MOD TCU
LST TCU
TCU TempIn Temperature In eNodeB DSP TCU

TCU TempOut Temperature Out eNodeB DSP TCU

TCU TempInner Temperature Inner eNodeB DSP TCU

Inner Cycle Fan


TCU InCycleSpeedRate eNodeB DSP TCU
Average Speed
OutCycleSpeedRat Outer Cycle Fan
TCU eNodeB DSP TCU
e Average Speed

TCU AlarmState Alarm Status eNodeB None

TCU OpState Operational State eNodeB None

TCU AvailabilityStatus Availability Status eNodeB None

TCU Elabel Electronic Label eNodeB None

TCU BoardType Type eNodeB None

TCU BoardSerial Serial Number eNodeB None

TCU BoardDesc Description eNodeB None

Date of
TCU BoardManu eNodeB None
Manufacture
TCU BoardVendor Vendor eNodeB None

TCU BoardIssue Issue Number eNodeB None

TCU RuType Config Type eNodeB None

TCU ObjectNumber Object Number eNodeB None

TCU ObjectType Object Type eNodeB None

TCU BoardTemperature Board Temperature eNodeB None

TCU HPATemperature HPA Temperature eNodeB None

TCU OperateResult Operate Result eNodeB None

TCU ServiceType Service Type eNodeB None

TCU DEVTYPE DEVTYPE eNodeB None

TCU NeName Office Name eNodeB None

TCU SoftVer Software Version eNodeB None

TCU HardVer Hardware Version eNodeB None

TCU BtrmVer BootRom Version eNodeB None

TCU HwTestTime Test Time eNodeB None

TCU TestResult Test Result eNodeB None

Downlink
TCU DLFREQ eNodeB None
Frequency

TCU ULFREQ Uplink Frequency eNodeB None

LST HTCDPA
HtCDPa CN Cabinet No. eNodeB
MOD HTCDPA
LST HTCDPA
HtCDPa SRN Subrack No. eNodeB
MOD HTCDPA
LST HTCDPA
HtCDPa SN Slot No. eNodeB
MOD HTCDPA
Low Temperature MOD HTCDPA
HtCDPa LTCP eNodeB
Critical Point LST HTCDPA
High Temperature MOD HTCDPA
HtCDPa HTCP eNodeB
Critical Point LST HTCDPA
Temperature Limit MOD HTCDPA
HtCDPa TLT eNodeB
at Air Outlet LST HTCDPA
MOD HTCDPA
HtCDPa DBD Dead Band eNodeB
LST HTCDPA
Normal
MOD HTCDPA
HtCDPa NTDI Temperature Delta eNodeB
LST HTCDPA
Tin
Normal
MOD HTCDPA
HtCDPa NTDO Temperature Delta eNodeB
LST HTCDPA
Tout
High Temperature MOD HTCDPA
HtCDPa HTDO eNodeB ADD PMU
Delta Tout LST HTCDPA
CLR PMUALM
DSP PMU
PMU CN Cabinet No. eNodeB ADD PMU
LST PMU
CLR PMUALM
MOD PMU
DSP
RMV PMU
PMU
PMU SRN Subrack No. eNodeB ADD PMU
LST PMU
CLR PMUALM
MOD PMU
DSP
RMV PMU
PMU
PMU SN Slot No. eNodeB
LST PMU
MOD PMU
Manager Cabinet ADD
RMV PMU
PMU
PMU MCN eNodeB
No. LST PMU
Manager Subrack ADD PMU
PMU MSRN eNodeB
No. LST PMU
ADD PMU
PMU MPN Manager Port No. eNodeB MOD PMU
LST PMU
ADD PMU
PMU ADDR Address eNodeB MOD PMU
LST PMU
ADD PMU
PMU PTYPE Power System Type eNodeB MOD PMU
LST PMU
ADD PMU
AC Voltage Alarm
PMU ACVLTHD eNodeB MOD PMU
Lower Threshold
LST PMU
ADD PMU
AC Voltage Alarm
PMU ACVUTHD eNodeB MOD PMU
Upper Threshold
LST PMU
ADD PMU
DC Voltage Alarm
PMU DCVLTHD eNodeB MOD PMU
Lower Threshold
LST PMU
ADD PMU
DC Voltage Alarm
PMU DCVUTHD eNodeB MOD PMU
Upper Threshold
LST PMU
ADD PMU
Load Shutdown
PMU LSDF eNodeB MOD PMU
Flag
LST PMU
ADD PMU
Load Shutdown
PMU LSDV eNodeB MOD PMU
Voltage
LST PMU
Cabinet ADD PMU
PMU ATLTHD Temperature Alarm eNodeB MOD PMU
Lower Threshold LST PMU
Cabinet ADD PMU
PMU ATUTHD Temperature Alarm eNodeB MOD PMU
Upper Threshold LST PMU
Cabinet Humidity ADD PMU
PMU AHLTHD Alarm Lower eNodeB MOD PMU
Threshold LST PMU
Cabinet Humidity ADD PMU
PMU AHUTHD Alarm Upper eNodeB MOD PMU
Threshold LST PMU
ADD PMU
Special Analog
PMU SAAF eNodeB MOD PMU
Alarm Flag
LST PMU
ADD PMU
Special Boolean
PMU SBAF eNodeB MOD PMU
Alarm Flag
LST PMU
PMU AcVol AC Voltage eNodeB DSP PMU

PMU DcVol Busbar Voltage eNodeB DSP PMU

PMU LoadCurrent Load Total Current eNodeB DSP PMU

PMU LoadTemp Temperature eNodeB DSP PMU

PMU Humidity Cabinet Humidity eNodeB DSP PMU

Secondary Load
PMU ScdLoadPwrState eNodeB DSP PMU
Power State
Charging/Dischargi
PMU BatChargeState eNodeB DSP BATTERY
ng State
DSP BATTERY
PMU BatCurrent Battery Current eNodeB
DSP PMU
BatCurrentLimitStat Current Limiting
PMU eNodeB DSP PMU
e State

PMU BatPowerState Battery Power State eNodeB DSP BATTERY

PMU BatRemainCapacity Remaining Capacity eNodeB DSP BATTERY

Battery
PMU BatTemp eNodeB DSP BATTERY
Temperature

PMU BatTestPhase Battery Test Phase eNodeB DSP BATTERY

PhotovoltaicArrayC Photovoltaic Array


PMU eNodeB DSP PMU
urrent Total Current
Diesel Generator
PMU DieselCurrent eNodeB DSP PMU
Current
Auxiliary Battery
AuxBatCabinetTem
PMU Cabinet eNodeB DSP PMU
p
Temperature
PMU SoftwareVersion Software Version eNodeB DSP PMU

PMU PCBVersion PCB Version eNodeB DSP PMU

PMU EPLDVersion EPLD Version eNodeB DSP PMU

PMU SoftwareBuildTime Software Build Time eNodeB DSP PMU

PMU VersionDescription Version Description eNodeB DSP PMU


PMU ProduceDate Produce Date eNodeB DSP PMU

PMU Manufacturer Manufacturer eNodeB DSP PMU


PSU Intelligent
PMU ISCapability Shutdown eNodeB DSP PMU
Capability
PSU Intelligent
PMU ISSwitchState eNodeB DSP PMU
Shutdown Switch

PMU ISExecuteResult Execute Result eNodeB None

PMU AlarmState Alarm Status eNodeB None

PMU OpState Operational State eNodeB None

PMU AvailabilityStatus Availability Status eNodeB None

PMU Elabel Electronic Label eNodeB None

PMU BoardType Type eNodeB None

PMU BoardSerial Serial Number eNodeB None

PMU BoardDesc Description eNodeB None

Date of
PMU BoardManu eNodeB None
Manufacture

PMU BoardVendor Vendor eNodeB None

PMU BoardIssue Issue Number eNodeB None

PMU RuType Config Type eNodeB None

PMU ObjectNumber Object Number eNodeB None

PMU ObjectType Object Type eNodeB None

PMU BoardTemperature Board Temperature eNodeB None

PMU HPATemperature HPA Temperature eNodeB None

PMU OperateResult Operate Result eNodeB None

PMU ServiceType Service Type eNodeB None

PMU DEVTYPE DEVTYPE eNodeB None


PMU NeName Office Name eNodeB None

PMU SoftVer Software Version eNodeB None

PMU HardVer Hardware Version eNodeB None

PMU BtrmVer BootRom Version eNodeB None

PMU HwTestTime Test Time eNodeB None

PMU TestResult Test Result eNodeB None

Downlink
PMU DLFREQ eNodeB None
Frequency
ADD DIESELGEN
PMU ULFREQ Uplink Frequency eNodeB DSP
NoneDIESELGEN
LST DIESELGEN
ADD
MOD DIESELGEN
DIESELGEN
DieselGen CN Cabinet No. eNodeB DSP
RMV DIESELGEN
DIESELGEN
LST
STP DIESELGEN
ADD
MOD DIESELGEN
DIESELGEN
DIESELGENTST
DSP DIESELGEN
DieselGen SRN Subrack No. eNodeB RMV
STR DIESELGEN
LST DIESELGEN
STP
DIESELGENTST
MOD DIESELGEN
DIESELGENTST
DieselGen SN Slot No. eNodeB RMV
STR DIESELGEN
STP
DIESELGENTST
ADD DIESELGEN
DIESELGENTST
Intelligent Control
DieselGen ICF eNodeB MOD
STR DIESELGEN
Flag
LST DIESELGEN
DIESELGENTST
ADD DIESELGEN
DieselGen POWER Rated Power eNodeB MOD DIESELGEN
LST DIESELGEN
DieselGen OL Oil Level eNodeB DSP DIESELGEN

Diesel Generator
DieselGen DGC eNodeB DSP DIESELGEN
Current

DieselGen TRT Total Running Time eNodeB ADD BATTERY


DSP DIESELGEN
DSP BATINDT
DSP BATTERY
Battery CN Cabinet No. eNodeB ADD BATTERY
LST BATTERY
DSP BATINDT
MOD BATINDT
DSP
MOD BATTERY
BATTERY
Battery SRN Subrack No. eNodeB ADD
LST BATTERY
BATTERY
RMV
DSP BATTERY
BATINDT
MOD BATINDT
DSP
MODBATTERY
BATTERY
Battery SN Slot No. eNodeB LST
RMVBATTERY
BATTERY
MOD BATINDT
ADD
MOD BATTERY
BATTERY
Battery INSTALLTYPE Installation Type eNodeB MOD BATTERY
RMV BATTERY
LST BATTERY
ADD BATTERY
Boost-Charging
Battery BCD eNodeB MOD BATTERY
Duration
LST BATTERY
ADD BATTERY
Boost-Charging
Battery BCV eNodeB MOD BATTERY
Voltage
LST BATTERY
ADD BATTERY
Battery BC1 Battery 1 Capacity eNodeB MOD BATTERY
LST BATTERY
ADD BATTERY
Battery Current
Battery BCLC eNodeB MOD BATTERY
Limiting Coefficient
LST BATTERY
ADD BATTERY
Float-Charging
Battery FCV eNodeB MOD BATTERY
Voltage
LST BATTERY
ADD BATTERY
High Temperature
Battery HTSDF eNodeB MOD BATTERY
Shutdown Flag
LST BATTERY
ADD BATTERY
Shutdown
Battery SDT eNodeB MOD BATTERY
Temperature
LST BATTERY
ADD BATTERY
Low Voltage
Battery LVSDF eNodeB MOD BATTERY
Shutdown Flag
LST BATTERY
ADD BATTERY
Battery SDV Shutdown Voltage eNodeB MOD BATTERY
LST BATTERY
Temperature ADD BATTERY
Battery TCC Compensation eNodeB MOD BATTERY
Coefficient LST BATTERY
ADD BATTERY
Temperature Alarm
Battery TLTHD eNodeB MOD BATTERY
Lower Threshold
LST BATTERY
ADD BATTERY
Temperature Alarm
Battery TUTHD eNodeB MOD BATTERY
Upper Threshold
LST BATTERY
ADD BATTERY
MOD BATTERY
Battery BN Battery Number eNodeB
DSP BATTERY
ADD BATTERY
LST BATTERY
MOD BATTERY
Battery BTYPE Battery Type eNodeB
DSP BATTERY
LST BATTERY
Battery PCT Power Cut Times eNodeB DSP BATTERY

Charge Times In
Battery CTHALF eNodeB DSP BATTERY
Half an Hour
Charge Times In 1
Battery CT1H eNodeB DSP BATTERY
Hour
Charge Times In 2
Battery CT2H eNodeB DSP BATTERY
Hours
Charge Times In 3
Battery CT3H eNodeB DSP BATTERY
Hours
Charge Times In 4
Battery CT4H eNodeB DSP BATTERY
Hours
Charge Times In 5
Battery CT5H eNodeB DSP BATTERY
Hours
Charge Times In 6
Battery CT6H eNodeB DSP BATTERY
Hours
Charge Times In 7
Battery CT7H eNodeB DSP BATTERY
Hours
Charge Times In 8
Battery CT8H eNodeB DSP BATTERY
Hours
Charge Times In
Battery CT8UH eNodeB DSP BATTERY
More than 8 Hours
Discharge Times In
Battery DCTHALF eNodeB DSP BATTERY
Half an Hour
Discharge Times In
Battery DCT1 eNodeB DSP BATTERY
1 Hour
Discharge Times In
Battery DCT2 eNodeB DSP BATTERY
2 Hours
Discharge Times In
Battery DCT3 eNodeB DSP BATTERY
3 Hours
Discharge Times In
Battery DCT4 eNodeB DSP BATTERY
4 Hours
Discharge Times In
Battery DCT5 eNodeB DSP BATTERY
5 Hours
Discharge Times In
Battery DCT6 eNodeB DSP BATTERY
6 Hours
Discharge Times In
Battery DCT7 eNodeB DSP BATTERY
7 Hours
Discharge Times In
Battery DCT8 eNodeB DSP BATTERY
8 Hours
Discharge Times In
Battery DCTU8 eNodeB DSP BATTERY
More than 8 Hours
MOD BATINDT
Battery DATE Installation Date eNodeB
DSP BATINDT
ADD BATTERY
Battery BC2 Battery 2 Capacity eNodeB MOD BATTERY
DSP BATTR
LST BATTERY
LST BATCTPA
BatCTPa CN Cabinet No. eNodeB MOD BATCTPA
DSP BATTR
STP BATTST
LST
STR BATCTPA
BATTST
BatCTPa SRN Subrack No. eNodeB MOD BATCTPA
DSP BATTR
STP BATTST
LST BATCTPA
STR BATTST
BatCTPa SN Slot No. eNodeB MOD BATCTPA
STP BATTST
0.05C10 Discharge STR
MODBATTST
BATCTPA
BatCTPa DSCHGT0 eNodeB
Time LST BATCTPA
0.1C10 Discharge MOD BATCTPA
BatCTPa DSCHGT1 eNodeB
Time LST BATCTPA
0.2C10 Discharge MOD BATCTPA
BatCTPa DSCHGT2 eNodeB
Time LST BATCTPA
0.3C10 Discharge MOD BATCTPA
BatCTPa DSCHGT3 eNodeB
Time LST BATCTPA
0.4C10 Discharge MOD BATCTPA
BatCTPa DSCHGT4 eNodeB
Time LST BATCTPA
0.5C10 Discharge MOD BATCTPA
BatCTPa DSCHGT5 eNodeB
Time LST BATCTPA
0.6C10 Discharge MOD BATCTPA
BatCTPa DSCHGT6 eNodeB
Time LST BATCTPA
0.7C10 Discharge MOD BATCTPA
BatCTPa DSCHGT7 eNodeB
Time LST BATCTPA
0.8C10 Discharge MOD BATCTPA
BatCTPa DSCHGT8 eNodeB
Time LST BATCTPA
0.9C10 Discharge MOD BATCTPA
BatCTPa DSCHGT9 eNodeB
Time LST BATCTPA
Battery Charge MOD BATCTPA
BatCTPa EFF eNodeB
Efficiency LST BATCTPA
Discharge Test End MOD BATCTPA
BatCTPa ENDV eNodeB
Voltage LST BATCTPA
MOD BATCTPA
BatCTPa BATNUM Battery Number eNodeB
LST BATCTPA
Discharge Test MOD BATCTPA
BatCTPa DSTML eNodeB
Time Limit LST BATCTPA
Simple Discharge MOD BATCTPA
BatCTPa SDSTML eNodeB
Test Time Limit LST BATCTPA
Simple Discharge MOD BATCTPA
BatCTPa SDSEV eNodeB
Test End Voltage LST BATCTPA
Automatic Test MOD BATCTPA
BatCTPa ATMODE eNodeB
Mode LST BATCTPA
Timing Discharge MOD BATCTPA
BatCTPa TDSTM eNodeB
Test Time LST BATCTPA
Delayed Discharge MOD BATCTPA
BatCTPa DDSTM eNodeB
Test Time LST BATCTPA
STR BATTST
BatCTPa TYPE Battery Test Type eNodeB
DSP BATTR

BatCTPa TstStrDateTime Test Start Time eNodeB DSP BATTR

BatCTPa TstEndReason Test End Cause eNodeB DSP BATTR

BatCTPa TstResult Test Result eNodeB DSP BATTR

BatCTPa TstEffi Battery Efficency eNodeB DSP BATTR

Discharge Last
BatCTPa TstDischrLstTime eNodeB DSP BATTR
Time
Discharge End
BatCTPa TstDischrEndVol eNodeB DSP BATTR
Voltage
Discharge Average
BatCTPa TstDischrCurr eNodeB DSP BATTR
Current

BatCTPa TstDischrAh Discharge AH eNodeB DSP BATTR

Battery
BatCTPa TstBatTemp eNodeB DSP BATTR
Temperature
ADD PSU
DSP PSU
PSU CN Cabinet No. eNodeB
LST PSU
ADD
RMV PSU
PSU
DSP PSU
PSU SRN Subrack No. eNodeB
LST PSU
ADD
RMV PSU
PSU
DSP PSU
PSU SN Slot No. eNodeB
LST PSU
RMV PSU
PSU RunningStatus Running Status eNodeB DSP PSU

PSU ProduceDate Produce Date eNodeB DSP PSU

PSU Manufacturer Manufacturer eNodeB DSP PSU

PSU AlarmState Alarm Status eNodeB None

PSU OpState Operational State eNodeB None

PSU AvailabilityStatus Availability Status eNodeB None

PSU Elabel Electronic Label eNodeB None

PSU BoardType Type eNodeB None

PSU BoardSerial Serial Number eNodeB None

PSU BoardDesc Description eNodeB None

Date of
PSU BoardManu eNodeB None
Manufacture

PSU BoardVendor Vendor eNodeB None

PSU BoardIssue Issue Number eNodeB None

PSU RuType Config Type eNodeB None

PSU ObjectNumber Object Number eNodeB None

PSU ObjectType Object Type eNodeB None

PSU BoardTemperature Board Temperature eNodeB None

PSU HPATemperature HPA Temperature eNodeB None

PSU OperateResult Operate Result eNodeB None

PSU ServiceType Service Type eNodeB None

PSU DEVTYPE DEVTYPE eNodeB None

PSU NeName Office Name eNodeB None

PSU SoftVer Software Version eNodeB None


PSU HardVer Hardware Version eNodeB None

PSU BtrmVer BootRom Version eNodeB None

PSU HwTestTime Test Time eNodeB None

PSU TestResult Test Result eNodeB None

Downlink
PSU DLFREQ eNodeB None
Frequency

PSU ULFREQ Uplink Frequency eNodeB None

LST OUTPORT
OutPort CN Cabinet No. eNodeB
SET OUTPORT
LST OUTPORT
OutPort SRN Subrack No. eNodeB
SET OUTPORT
LST OUTPORT
OutPort SN Slot No. eNodeB
SET OUTPORT
LST OUTPORT
OutPort PN Port No. eNodeB
SET OUTPORT
SET OUTPORT
OutPort NAME Port Name eNodeB
LST OUTPORT
SET OUTPORT
OutPort SW Port Switch eNodeB
LST OUTPORT
LST ALMPORT
AlmPort CN Cabinet No. eNodeB
SET ALMPORT
LST ALMPORT
AlmPort SRN Subrack No. eNodeB
SET ALMPORT
LST ALMPORT
AlmPort SN Slot No. eNodeB
SET ALMPORT
LST ALMPORT
AlmPort PN Port No. eNodeB
SET ALMPORT
SET ALMPORT
AlmPort SW Switch eNodeB
LST ALMPORT
LST ALMPORT
AlmPort AID Alarm ID eNodeB
SET ALMPORT
SET ALMPORT
AlmPort PT Port Type eNodeB
LST ALMPORT
SET ALMPORT
AlmPort AVOL Alarm Voltage eNodeB
LST ALMPORT
SET ALMPORT
AlmPort UL Alarm Upper Limit eNodeB
LST ALMPORT
SET ALMPORT
AlmPort LL Alarm Lower Limit eNodeB
LST ALMPORT
SET ALMPORT
AlmPort ST Sensor Type eNodeB
LST ALMPORT
Sensor
SET ALMPORT
AlmPort SMUL Measurement eNodeB
LST ALMPORT
Upper Limit
Sensor
SET ALMPORT
AlmPort SMLL Measurement eNodeB
LST ALMPORT
Lower Limit
Sensor Output SET ALMPORT
AlmPort SOUL eNodeB
Upper Limit LST ALMPORT
Sensor Output SET ALMPORT
AlmPort SOLL eNodeB
Lower Limit LST ALMPORT
SET
Authentication
SSL AUTHMODE eNodeB SSLAUTHMODE
Mode ADD NTPC
LST SSLCONF
MOD NTPC
IpV4 Address of
NtpCp IP eNodeB RMV NTPC
NTP Server
SET
ADD NTPC
MASTERNTPS
Synchronization
NtpCp SYNCCYCLE eNodeB MOD NTPC
Period
LST NTPC
ADD NTPC
NtpCp PORT Port Number eNodeB MOD NTPC
LST NTPC
ADD NTPC
Synchronized
NtpCp SYNCSWITCH eNodeB MOD NTPC
Switch ADD NTPC
LST NTPC
MOD NTPC
NtpCp MODE IP Mode eNodeB RMV NTPC
ADD
SET NTPC
MOD NTPC
MASTERNTPS
IpV6 Address of
NtpCp IPV6 eNodeB RMV NTPC
NTP Server
SET
ADD NTPC
MASTERNTPS
Authentication
NtpCp AUTHMODE eNodeB MOD NTPC
Mode
LST NTPC
ADD NTPC
NtpCp KEY Authentication Key eNodeB MOD NTPC
LST NTPC
ADD NTPC
Authentication Key
NtpCp KEYID eNodeB MOD NTPC
Index
LST NTPC
NtpCp MASTERFLAG Master Flag eNodeB LST NTPC

SET TZ
TZ ZONET Time Zone eNodeB
LST TZ

TZ DST Dst Tag Information eNodeB SET TZ

TZ SM Dst Start Mode eNodeB SET TZ

TZ SMONTH Dst Start Month eNodeB SET TZ

TZ SDAY Dst Start Day eNodeB SET TZ

Dst Start Week


TZ SWSEQ eNodeB SET TZ
Sequence

TZ SWEEK Dst Start Weekday eNodeB SET TZ

TZ ST Dst Start Time eNodeB SET TZ


TZ EM Dst End Mode eNodeB SET TZ

TZ EMONTH Dst End Month eNodeB SET TZ

TZ EDAY Dst End Day eNodeB SET TZ

Dst End Week


TZ EWSEQ eNodeB SET TZ
Sequence

TZ EWEEK Dst End Weekday eNodeB SET TZ

TZ ET Dst End Time eNodeB SET TZ

TZ TO DST Offset eNodeB SET TZ

TZ TIMEDIFF Time Difference eNodeB SET TZ

OmuCurTime DATE Date eNodeB SET TIME

OmuCurTime TIME Time eNodeB SET TIME

OmuCurTime DATETIME Time eNodeB DSP TIME


SET TIMESRC
DSP TIMESRC
LST
ADD
TimeSrc TIMESRC Time Source eNodeB
LATESTSUCCDAT
CNOPERATOREXT
Latest Successful E
LST
ENDEDQCI
TimeSrc DATETIME Synchronization eNodeB LST
LST TIMESRC
ADD
LATESTSUCCDAT
Time CNOPERATOREXT
E
CNOPERATOREXT
ENDEDQCI
ENDEDQCI
CnOperatorExtendedCnOperatorId CN Operator ID eNodeB LST
MOD
CNOPERATOREXT
ADD
CNOPERATOREXT
CN Operator ENDEDQCI
CNOPERATOREXT
ENDEDQCI
CnOperatorExtendedExtendedQci eNodeB
extended QCI MOD
ENDEDQCI
RMV
Service-based inter- CNOPERATOREXT
MOD
CNOPERATOREXT
ServiceIrHoCfgGro ENDEDQCI
CnOperatorExtended RAT handover eNodeB CNOPERATOREXT
ENDEDQCI
LST
upId RMV
policy group ID ENDEDQCI
CNOPERATORSTA
CNOPERATOREXT
LST
NDARDQCI
CnOperatorStandardCnOperatorId CN Operator ID eNodeB ENDEDQCI
LST
CNOPERATOREXT
MOD
CNOPERATORSTA
ENDEDQCI
CNOPERATORSTA
QoS Class NDARDQCI
NDARDQCI
CnOperatorStandardQci eNodeB MOD
Indication MOD
CNOPERATORSTA
CNOPERATORSTA
Service-based inter-
ServiceIrHoCfgGro NDARDQCI
NDARDQCI
CnOperatorStandard RAT handover eNodeB LST
upId LST
policy group ID CSFALLBACKBLIN
CNOPERATORSTA
DHOCFG
NDARDQCI
CSFallBackBlindHoCCnOperatorId CN Operator ID eNodeB MOD
MOD
CSFALLBACKBLIN
CSFALLBACKBLIN
Highest priority DHOCFG
DHOCFG
CSFallBackBlindHoCInterRatHighestPri eNodeB MOD
InterRat LST
CSFALLBACKBLIN
CSFALLBACKBLIN
Second priority DHOCFG
DHOCFG
CSFallBackBlindHoCInterRatSecondPri eNodeB MOD
InterRat LST
CSFALLBACKBLIN
CSFALLBACKBLIN
Lowest priority DHOCFG
DHOCFG
CSFallBackBlindHoCInterRatLowestPri eNodeB
InterRat LST
CSFALLBACKBLIN
DHOCFG
MOD
CSFALLBACKBLIN
UTRAN LCS DHOCFG
CSFallBackBlindHoCUtranLcsCap eNodeB MOD
capability LST
CSFALLBACKBLIN
CSFALLBACKBLIN
GERAN LCS DHOCFG
DHOCFG
ADD
CSFallBackBlindHoCGeranLcsCap eNodeB MOD
capability LST
RATFREQPRIORIT
CSFALLBACKBLIN
CSFALLBACKBLIN
CDMA2000 LCS YGROUP
DHOCFG
CSFallBackBlindHoCCdmaLcsCap eNodeB DHOCFG
ADD
LST
capability LST
RATFREQPRIORIT
RATFREQPRIORIT
CSFALLBACKBLIN
RatFreqPriorityGrou RAT frequency YGROUP
YGROUP
RatFreqPriorityGrou eNodeB DHOCFG
ADD
LST
pId priority group ID MOD
RATFREQPRIORIT
RATFREQPRIORIT
RATFREQPRIORIT
YGROUP
YGROUP
RatFreqPriorityGrou RatType RAT Type eNodeB YGROUP
LST
MOD
RMV
RATFREQPRIORIT
ADD
RATFREQPRIORIT
RATFREQPRIORIT
YGROUP
RatFreqPriorityGrou DlEarfcn Downlink EARFCN eNodeB RATFREQPRIORIT
YGROUP
ADD
YGROUP
MOD
YGROUP
RMV
SERVICEIRHOCF
RATFREQPRIORIT
MOD
RATFREQPRIORIT
GGROUP
RatFreqPriorityGrou Priority Priority eNodeB YGROUP
ADD
RATFREQPRIORIT
YGROUP
LST
RMV
SERVICEIRHOCF
YGROUP
SERVICEIRHOCF
RATFREQPRIORIT
GGROUP
LST
GGROUP
ServiceIrHoCfgGrou CnOperatorId CN Operator ID eNodeB YGROUP
LST
RATFREQPRIORIT
MOD
SERVICEIRHOCF
YGROUP
ADD
SERVICEIRHOCF
Service-based inter-
ServiceIrHoCfgGro GGROUP
SERVICEIRHOCF
GGROUP
ServiceIrHoCfgGrou RAT handover eNodeB
upId MOD
GGROUP
RMV
policy group ID
SERVICEIRHOCF
MOD
SERVICEIRHOCF
Inter-RAT handover GGROUP
ServiceIrHoCfgGrou InterRatHoState eNodeB SERVICEIRHOCF
GGROUP
state RMV
GGROUP
ADD SPIDCFG
SERVICEIRHOCF
LST
LST SPIDCFG
SpidCfg Spid Spid eNodeB GGROUP
SERVICEIRHOCF
MOD SPIDCFG
GGROUP
RMV SPIDCFG
ADD SPIDCFG
SpidCfg DrxStatus Drx status eNodeB MOD SPIDCFG
LST SPIDCFG
ADD SPIDCFG
RAT frequency
SpidCfg RatFreqPriorityInd eNodeB MOD SPIDCFG
priority indication
LST SPIDCFG
ADD SPIDCFG
RatFreqPriorityGrou RAT frequency
SpidCfg eNodeB MOD SPIDCFG
MOD
pId priority group ID
LST SPIDCFG
COUNTERCHECK
PARA
CounterCheckPara CounterCheckTimer Counter check timer eNodeB MOD
LST
COUNTERCHECK
COUNTERCHECK
CounterCheckCoun Counter check PARA
PARA
CounterCheckPara eNodeB MOD
tNum count number LST
COUNTERCHECK
COUNTERCHECK
CounterCheckUser Counter check user PARA
PARA
CounterCheckPara eNodeB MOD
RelSwitch Release switch LST
ENODEBCIPHERC
COUNTERCHECK
Primary cipher AP
PARA
ENodeBCipherCap PrimaryCipherAlgo eNodeB MOD
algorithm LST
ENODEBCIPHERC
ENODEBCIPHERC
Second cipher AP
AP
ENodeBCipherCap SecondCipherAlgo eNodeB MOD
algorithm LST
ENODEBCIPHERC
ENODEBCIPHERC
Third cipher AP
AP
ENodeBCipherCap ThirdCipherAlgo eNodeB MOD
algorithm LST
ENODEBINTEGRIT
ENODEBCIPHERC
PrimaryIntegrityAlg Primary integrity YCAP
AP
ENodeBIntegrityCap eNodeB MOD
o algorithm LST
ENODEBINTEGRIT
ENODEBINTEGRIT
SecondIntegrityAlg Second integrity YCAP
YCAP
ENodeBIntegrityCap eNodeB MOD
o algorithm LST
ENODEBINTEGRIT
ENODEBINTEGRIT
Third integrity YCAP
YCAP
ENodeBIntegrityCap ThirdIntegrityAlgo eNodeB
algorithm LST
ENODEBINTEGRIT
YCAP
MOD
GLOBALPROCSWI
X2SonLinkSetupTy The method of X2 TCH
GlobalProcSwitch eNodeB MOD
pe setup by SON LST
GLOBALPROCSWI
GLOBALPROCSWI
TCH
TCH
GlobalProcSwitch SriAdaptiveSwitch SRI adaptive switch eNodeB MOD
LST
GLOBALPROCSWI
GLOBALPROCSWI
TCH
TCH
GlobalProcSwitch LcgProfile LCG Profile eNodeB
LST
MOD
GLOBALPROCSWI
PDCPROHCPARA
TCH
PdcpRohcPara RohcSwitch ROHC switch eNodeB
LST
MOD
PDCPROHCPARA
ROHC Highest PDCPROHCPARA
PdcpRohcPara HighestMode eNodeB
mode LST
MOD
PDCPROHCPARA
Compression PDCPROHCPARA
PdcpRohcPara Profiles eNodeB MOD
profiles LST
RRCCONNSTATET
PDCPROHCPARA
IMER
RrcConnStateTimer T302 Timer302 eNodeB MOD
LST
RRCCONNSTATET
RRCCONNSTATET
T320ForLoadBalan Timer320 for load IMER
IMER
RrcConnStateTimer eNodeB MOD
ce balance LST
RRCCONNSTATET
RRCCONNSTATET
Timer304 for IMER
IMER
RrcConnStateTimer T304ForEutran eNodeB MOD
EUTRAN LST
RRCCONNSTATET
RRCCONNSTATET
Timer304 for IMER
IMER
RrcConnStateTimer T304ForGeran eNodeB MOD
GERAN LST
RRCCONNSTATET
RRCCONNSTATET
IMER
IMER
RrcConnStateTimer T320ForOther Timer320 for other eNodeB MOD
LST
RRCCONNSTATET
RRCCONNSTATET
IMER
IMER
RrcConnStateTimer UeInactiveTimer Ue inactive timer eNodeB
LST
MOD
RRCCONNSTATET
WAITUEUURSPTI RRSTATETIMER
IMER
RRSTATETIMER WaitUEUuRspTimer eNodeB
MER LST
MOD
RRSTATETIMER
WAITMMES1RSPTI WaitMMES1RspTim RRSTATETIMER
RRSTATETIMER eNodeB
MER er LST
MOD
RRSTATETIMER
WAITENBX2RSPTI WaitENBX2RspTim RRSTATETIMER
RRSTATETIMER eNodeB
MER er LST
MOD
RRSTATETIMER
WAITINTERRATSY WaitInterRATSysHo RRSTATETIMER
RRSTATETIMER eNodeB
SHORSPTIMER RspTimer LST
MOD
RRSTATETIMER
WAITMMEINITUEC
WaitMMEInitUECnt RRSTATETIMER
RRSTATETIMER NTSETUPREQTIM eNodeB
SetupReqTimer LST
ER MOD
RRSTATETIMER
RRSTATETIMER
RRSTATETIMER UERESYNCTIMER UeReSyncTimer eNodeB LST
LST
CELLDLPCPDSCH
RRSTATETIMER
PA
CellDlpcPdschPa LocalCellId Local cell identity eNodeB MOD
MOD
CELLDLPCPDSCH
CELLDLPCPDSCH
PA
PA
CellDlpcPdschPa PdschPaAdjSwitch PA adjusting switch eNodeB MOD
LST
CELLDLPCPDSCH
CELLDLPCPDSCH
PA for even power PA
PA
CellDlpcPdschPa PaPcOff eNodeB
distribution LST
LST
CELLDLPCPDSCH
CELLDRXPARA
PA
CellDrxPara LocalCellId Local cell identity eNodeB
MOD
MOD
CELLDRXPARA
FDD enter DRX CELLDRXPARA
CellDrxPara FddEnterDrxThd eNodeB
threshold LST
CELLDRXPARA
MOD
FDD exit DRX CELLDRXPARA
CellDrxPara FddExitDrxThd eNodeB
threshold LST
MOD
CELLDRXPARA
TDD enter DRX CELLDRXPARA
CellDrxPara TddEnterDrxThdUl eNodeB
threshold Uplink LST
MOD
CELLDRXPARA
TDD exit DRX CELLDRXPARA
CellDrxPara TddExitDrxThdUl eNodeB
threshold Uplink LST
MOD
CELLDRXPARA
TDD enter DRX CELLDRXPARA
CellDrxPara TddEnterDrxThdDl eNodeB
threshold Downlink LST
MOD
CELLDRXPARA
TDD exit DRX CELLDRXPARA
CellDrxPara TddExitDrxThdDl eNodeB
threshold Downlink LST
MOD
CELLDRXPARA
DataAmountStatTi Data amount CELLDRXPARA
CellDrxPara eNodeB
mer Statistic timer LST
LST
CELLDRXPARA
CELLULPCDEDIC
CellUlpcDedic LocalCellId Local cell identity eNodeB
MOD
MOD
CELLULPCDEDIC
Delta-MCS enable CELLULPCDEDIC
CellUlpcDedic DeltaMcsEnabled eNodeB
or disable indication LST
MOD
CELLULPCDEDIC
PSrsOffset when
PSrsOffsetDeltaMc CELLULPCDEDIC
CellUlpcDedic DeltaMcsEnalbed is eNodeB
sDisable LST
UU_DISABLE MOD
PSrsOffset when CELLULPCDEDIC
PSrsOffsetDeltaMc CELLULPCDEDIC
CellUlpcDedic DeltaMcsEnalbed is eNodeB
sEnable LST
UU_ENABLE MOD
CELLULPCDEDIC
ADD
RSRP filtering CELLULPCDEDIC
CellUlpcDedic FilterRsrp eNodeB DRXPARAGROUP
coefficient LST
LST
CELLULPCDEDIC
ADD
DRXPARAGROUP
DrxParaGroup LocalCellId Local cell identity eNodeB DRXPARAGROUP
MOD
LST
DRXPARAGROUP
DRX parameter DRXPARAGROUP
RMV
DrxParaGroup DrxParaGroupId eNodeB ADD
group ID MOD
DRXPARAGROUP
DRXPARAGROUP
DRXPARAGROUP
MOD
RMV
DrxParaGroup EnterDrxSwitch Enter DRX Switch eNodeB ADD
DRXPARAGROUP
DRXPARAGROUP
DRXPARAGROUP
LST
MOD
DRXPARAGROUP
DrxParaGroup OnDurationTimer On Duration Timer eNodeB ADD
DRXPARAGROUP
DRXPARAGROUP
LST
DRX Inactivity MOD
DRXPARAGROUP
DrxParaGroup DrxInactivityTimer eNodeB ADD
Timer DRXPARAGROUP
DRXPARAGROUP
LST
DRX
MOD
DRXPARAGROUP
DrxParaGroup DrxReTxTimer Retransmission eNodeB ADD
DRXPARAGROUP
Timer DRXPARAGROUP
LST
MOD
DRXPARAGROUP
DrxParaGroup LongDrxCycle Long DRX Cycle eNodeB ADD
DRXPARAGROUP
DRXPARAGROUP
LST
Short-cycle DRX
MOD
DRXPARAGROUP
DrxParaGroup SupportShortDrx supported eNodeB ADD
DRXPARAGROUP
indication DRXPARAGROUP
LST
MOD
DRXPARAGROUP
ADD
DrxParaGroup ShortDrxCycle Short DRX Cycle eNodeB ADD
DRXPARAGROUP
INTERRATHOCOM
DRXPARAGROUP
LST
DRX Short Cycle MGROUP
MOD
DrxParaGroup DrxShortCycleTimer eNodeB DRXPARAGROUP
ADD
LST
Timer DRXPARAGROUP
INTERRATHOCOM
INTERRATHOCOM
LST
MGROUP
MGROUP
InterRatHoCommGroLocalCellId Local cell identity eNodeB DRXPARAGROUP
LST
MOD
INTERRATHOCOM
INTERRATHOCOM
InterRatHoCommGr InterRAT handover MGROUP
MGROUP
InterRatHoCommGro eNodeB
oupId common group ID MOD
RMV
INTERRATHOCOM
INTERRATHOCOM
MGROUP
MGROUP
RMV
INTERRATHOCOM
MGROUP
ADD
INTERRATHOCOM
MGROUP
ADD
MOD
InterRatHoA1A2Hy InterRAT A1A2 INTERRATHOCOM
InterRatHoCommGro eNodeB INTERRATHOCOM
st hysteresis MGROUP
MGROUP
ADD
MOD
LST
InterRatHoA1A2Tim InterRAT A1A2 time INTERRATHOCOM
InterRatHoCommGro eNodeB INTERRATHOCOM
INTERRATHOCOM
eToTrig to trigger MGROUP
MGROUP
MGROUP
ADD
MOD
LST
InterRatHoA1ThdR InterRAT A1 RSRP INTERRATHOCOM
InterRatHoCommGro eNodeB INTERRATHOCOM
INTERRATHOCOM
srp trigger threshold MGROUP
MGROUP
MGROUP
ADD
MOD
LST
InterRatHoA1ThdR InterRAT A1 RSRQ INTERRATHOCOM
InterRatHoCommGro eNodeB INTERRATHOCOM
INTERRATHOCOM
srq trigger threshold MGROUP
MGROUP
MGROUP
ADD
MOD
LST
InterRatHoA2ThdR InterRAT A2 RSRP INTERRATHOCOM
ADD
InterRatHoCommGro eNodeB INTERRATHOCOM
INTERRATHOCOM
srp trigger threshold MGROUP
INTERRATHOCDM
MGROUP
MGROUP
MOD
A1XRTTGROUP
LST
InterRatHoA2ThdR InterRAT A2 RSRQ ADD
InterRatHoCommGro eNodeB INTERRATHOCOM
LST
INTERRATHOCOM
srq trigger threshold INTERRATHOCDM
MGROUP
INTERRATHOCDM
MGROUP
A1XRTTGROUP
LST
A1XRTTGROUP
InterRatHoCdma1xRtLocalCellId Local cell identity eNodeB LST
INTERRATHOCOM
MOD
InterRAT handover INTERRATHOCDM
MGROUP
ADD
INTERRATHOCDM
InterRatHoCdma1x to A1XRTTGROUP
INTERRATHOCDM
A1XRTTGROUP
InterRatHoCdma1xRt eNodeB
RttGroupId CDMA20001xRTT MOD
A1XRTTGROUP
RMV
group ID
CDMA20001XRTT ADD
INTERRATHOCDM
MOD
InterRatHoCdmaB1 INTERRATHOCDM
InterRatHoCdma1xRt handover eNodeB INTERRATHOCDM
A1XRTTGROUP
INTERRATHOCDM
Hyst A1XRTTGROUP
hysteresis A1XRTTGROUP
RMV
A1XRTTGROUP
CoverageBased ADD
MOD
InterRatHoCdmaB1 INTERRATHOCDM
LST
InterRatHoCdma1xRt CDMA20001XRTT eNodeB INTERRATHOCDM
INTERRATHOCDM
ThdPs A1XRTTGROUP
INTERRATHOCDM
trigger threshold A1XRTTGROUP
A1XRTTGROUP
A1XRTTGROUP
ADD
MOD
InterRatHoCdmaB1 CDMA20001XRTT LST
INTERRATHOCDM
InterRatHoCdma1xRt eNodeB ADD
INTERRATHOCDM
TimeToTrig time to trigger INTERRATHOCDM
A1XRTTGROUP
Load Service CELLEXTENDEDQ
A1XRTTGROUP
A1XRTTGROUP
MOD
LdSvBasedHoCdm Based CI
LST
InterRatHoCdma1xRt eNodeB ADD
INTERRATHOCDM
LST
aB1ThdPs CDMA20001XRTT INTERRATHOCDM
CELLEXTENDEDQ
A1XRTTGROUP
CELLEXTENDEDQ
trigger threshold A1XRTTGROUP
CI
LST
CI
CellExtendedQci ExtendedQci Extended QCI eNodeB LST
INTERRATHOCDM
MOD
CELLEXTENDEDQ
A1XRTTGROUP
ADD
CELLEXTENDEDQ
CI
CELLEXTENDEDQ
CI
CellExtendedQci LocalCellId Local cell identity eNodeB
MOD
CI
RMV
ADD
CELLEXTENDEDQ
MOD
InterFreqHoGroupI Interfreq handover CELLEXTENDEDQ
CellExtendedQci eNodeB CELLEXTENDEDQ
CI
CELLEXTENDEDQ
d group ID CI
CI
RMV
CI
InterRAT handover ADD
MOD
CELLEXTENDEDQ
LST
InterRatHoCdma1x to CELLEXTENDEDQ
CellExtendedQci eNodeB CELLEXTENDEDQ
CI
CELLEXTENDEDQ
RttGroupId CDMA20001xRTT CI
InterRAT CI
group ID handover CI
ADD
MOD
InterRatHoCdmaHr to LST
CELLEXTENDEDQ
CellExtendedQci eNodeB CELLEXTENDEDQ
CELLEXTENDEDQ
pdGroupId CDMA2000HRPD CI
CI
CI
ADD
group ID MOD
InterRatHoCommGr InterRAT handover LST
CELLEXTENDEDQ
CellExtendedQci eNodeB CELLEXTENDEDQ
CELLEXTENDEDQ
oupId common group ID CI
CI
CI
ADD
MOD
LST
InterRatHoGeranGr InterRAT handover CELLEXTENDEDQ
CellExtendedQci eNodeB CELLEXTENDEDQ
CELLEXTENDEDQ
oupId to GERAN group ID CI
CI
CI
ADD
MOD
LST
InterRatHoUtranGro InterRAT handover CELLEXTENDEDQ
CellExtendedQci eNodeB CELLEXTENDEDQ
CELLEXTENDEDQ
upId to UTRAN Group ID CI
CI
CI
ADD
MOD
LST
IntraFreqHoGroupI Intrafreq handover CELLEXTENDEDQ
CellExtendedQci eNodeB CELLEXTENDEDQ
CELLEXTENDEDQ
d group ID CI
CI
CI
MOD
LST
DRX parameter
CellExtendedQci DrxParaGroupId eNodeB CELLEXTENDEDQ
LST
CELLEXTENDEDQ
group ID
CI
CELLSTANDARDQ
CI
LST
CI
CellStandardQci LocalCellId Local cell identity eNodeB CELLEXTENDEDQ
MOD
CI
CELLSTANDARDQ
CI
LST
CELLSTANDARDQ
QoS Class CI
CellStandardQci Qci eNodeB MOD
Indication MOD
CELLSTANDARDQ
CELLSTANDARDQ
InterFreqHoGroupI Interfreq handover CI
CI
CellStandardQci eNodeB MOD
d group ID LST
InterRAT handover CELLSTANDARDQ
CELLSTANDARDQ
InterRatHoCdma1x to CI
CI
CellStandardQci eNodeB MOD
RttGroupId CDMA20001xRTT LST
InterRAT
group ID handover CELLSTANDARDQ
CELLSTANDARDQ
InterRatHoCdmaHr to CI
CI
CellStandardQci eNodeB MOD
pdGroupId CDMA2000HRPD LST
group ID CELLSTANDARDQ
CELLSTANDARDQ
InterRatHoCommGr InterRAT handover CI
CI
CellStandardQci eNodeB MOD
oupId common group ID LST
CELLSTANDARDQ
CELLSTANDARDQ
InterRatHoGeranGr InterRAT handover CI
CI
CellStandardQci eNodeB MOD
oupId to GERAN group ID LST
CELLSTANDARDQ
CELLSTANDARDQ
InterRatHoUtranGro InterRAT handover CI
CI
CellStandardQci eNodeB MOD
upId to UTRAN Group ID LST
CELLSTANDARDQ
CELLSTANDARDQ
IntraFreqHoGroupI Intrafreq handover CI
CI
CellStandardQci eNodeB MOD
d group ID LST
CELLSTANDARDQ
CELLSTANDARDQ
DRX parameter CI
CI
ADD
CellStandardQci DrxParaGroupId eNodeB MOD
group ID LST
INTERRATHOCDM
CELLSTANDARDQ
CELLSTANDARDQ
AHRPDGROUP
CI
CellStandardQci SriPeriod SRI Period eNodeB CI
ADD
LST
LST
INTERRATHOCDM
INTERRATHOCDM
CELLSTANDARDQ
AHRPDGROUP
AHRPDGROUP
InterRatHoCdmaHrp LocalCellId Local cell identity eNodeB CI
LST
MOD
InterRAT handover INTERRATHOCDM
ADD
INTERRATHOCDM
InterRatHoCdmaHr to AHRPDGROUP
INTERRATHOCDM
AHRPDGROUP
InterRatHoCdmaHrp eNodeB
pdGroupId CDMA2000HRPD MOD
AHRPDGROUP
RMV
group ID
CDMA2000HRPD ADD
INTERRATHOCDM
MOD
InterRatHoCdmaB1 INTERRATHOCDM
InterRatHoCdmaHrp handover eNodeB INTERRATHOCDM
AHRPDGROUP
INTERRATHOCDM
Hyst AHRPDGROUP
hysteresis AHRPDGROUP
RMV
AHRPDGROUP
CoverageBased ADD
MOD
InterRatHoCdmaB1 INTERRATHOCDM
LST
InterRatHoCdmaHrp CDMA2000HRPD eNodeB INTERRATHOCDM
INTERRATHOCDM
ThdPs AHRPDGROUP
INTERRATHOCDM
trigger threshold AHRPDGROUP
AHRPDGROUP
AHRPDGROUP
ADD
MOD
InterRatHoCdmaB1 CDMA2000HRPD LST
INTERRATHOCDM
InterRatHoCdmaHrp eNodeB ADD
INTERRATHOCDM
TimeToTrig time to trigger INTERRATHOCDM
AHRPDGROUP
Load Service INTERRATHOGER
AHRPDGROUP
AHRPDGROUP
MOD
LdSvBasedHoCdm Based ANGROUP
LST
InterRatHoCdmaHrp eNodeB ADD
INTERRATHOCDM
LST
aB1ThdPs CDMA2000HRPD INTERRATHOCDM
INTERRATHOGER
AHRPDGROUP
INTERRATHOGER
trigger threshold AHRPDGROUP
ANGROUP
LST
ANGROUP
InterRatHoGeranGroLocalCellId Local cell identity eNodeB LST
INTERRATHOCDM
MOD
INTERRATHOGER
AHRPDGROUP
ADD
INTERRATHOGER
InterRatHoGeranGr InterRAT handover ANGROUP
INTERRATHOGER
ANGROUP
InterRatHoGeranGro eNodeB
oupId to GERAN group ID MOD
ANGROUP
RMV
ADD
INTERRATHOGER
MOD
InterRatHoGeranB1 GERAN handover INTERRATHOGER
InterRatHoGeranGro eNodeB INTERRATHOGER
ANGROUP
INTERRATHOGER
Hyst hysteresis ANGROUP
ANGROUP
RMV
ANGROUP
CoverageBased ADD
MOD
InterRatHoGeranB1 INTERRATHOGER
LST
InterRatHoGeranGro GERAN trigger eNodeB INTERRATHOGER
INTERRATHOGER
Thd ANGROUP
INTERRATHOGER
threshold ANGROUP
ANGROUP
ANGROUP
ADD
MOD
InterRatHoGeranB1 GERAN time to LST
INTERRATHOGER
InterRatHoGeranGro eNodeB ADD
INTERRATHOGER
TimeToTrig trigger INTERRATHOGER
ANGROUP
Load Service INTERRATHOUTR
ANGROUP
ANGROUP
MOD
LdSvBasedHoGera Based Geran ANGROUP
LST
InterRatHoGeranGro eNodeB INTERRATHOGER
LST
INTERRATHOGER
nB1Thd EventB1 trigger
ANGROUP
INTERRATHOUTR
ANGROUP
threshold
LST
ANGROUP
InterRatHoUtranGro LocalCellId Local cell identity eNodeB INTERRATHOGER
MOD
ANGROUP
INTERRATHOUTR
ANGROUP
RMV
INTERRATHOUTR
ANGROUP
ADD
INTERRATHOUTR
ANGROUP
LST
INTERRATHOUTR
ADD
InterRatHoUtranGro InterRAT handover ANGROUP
INTERRATHOUTR
InterRatHoUtranGro eNodeB
upId to UTRAN Group ID MOD
ANGROUP
CoverageBased ADD
INTERRATHOUTR
MOD
InterRatHoUtranB1 INTERRATHOUTR
ANGROUP
InterRatHoUtranGro UTRAN ECN0 eNodeB INTERRATHOUTR
ThdEcn0 ANGROUP
RMV
trigger threshold ANGROUP
ADD
CoverageBased MOD
INTERRATHOUTR
LST
InterRatHoUtranB1 INTERRATHOUTR
InterRatHoUtranGro UTRAN RSCP eNodeB INTERRATHOUTR
ANGROUP
INTERRATHOUTR
ThdRscp ANGROUP
trigger threshold ANGROUP
ANGROUP
ADD
MOD
LST
InterRatHoUtranB1 UTRAN handover INTERRATHOUTR
InterRatHoUtranGro eNodeB INTERRATHOUTR
INTERRATHOUTR
Hyst hysteresis ANGROUP
ANGROUP
ANGROUP
ADD
MOD
LST
InterRatHoUtranB1 UTRAN time to INTERRATHOUTR
InterRatHoUtranGro eNodeB INTERRATHOUTR
INTERRATHOUTR
TimeToTrig trigger ANGROUP
ANGROUP
ANGROUP
ADD
Load Service MOD
LST
LdSvBasedHoUtran INTERRATHOUTR
ADD
InterRatHoUtranGro Based UTRANB1 eNodeB INTERRATHOUTR
INTERRATHOUTR
B1ThdEcn0 ANGROUP
INTERFREQHOGR
ECN0 threshold
Load Service ANGROUP
ANGROUP
MOD
OUP
LST
LdSvBasedHoUtran Based UTRAN ADD
InterRatHoUtranGro eNodeB INTERRATHOUTR
LST
INTERRATHOUTR
B1ThdRscp EventB1 RSCP INTERFREQHOGR
ANGROUP
INTERFREQHOGR
ANGROUP
trigger threshold OUP
LST
OUP
InterFreqHoGroup LocalCellId Local cell identity eNodeB LST
INTERRATHOUTR
MOD
INTERFREQHOGR
ANGROUP
ADD
INTERFREQHOGR
InterFreqHoGroupI Interfreq handover OUP
INTERFREQHOGR
OUP
InterFreqHoGroup eNodeB
d group ID MOD
OUP
RMV
ADD
INTERFREQHOGR
MOD
InterFreqHoA1A2H Interfreq A1A2 INTERFREQHOGR
InterFreqHoGroup eNodeB INTERFREQHOGR
OUP
INTERFREQHOGR
yst hysteresis OUP
OUP
RMV
OUP
ADD
MOD
InterFreqHoA1A2Ti Interfreq A1A2 time INTERFREQHOGR
LST
InterFreqHoGroup eNodeB INTERFREQHOGR
INTERFREQHOGR
meToTrig to trigger OUP
INTERFREQHOGR
OUP
OUP
OUP
ADD
MOD
InterFreqHoA1Thd Interfreq A1 RSRP LST
INTERFREQHOGR
InterFreqHoGroup eNodeB INTERFREQHOGR
INTERFREQHOGR
Rsrp threshold OUP
OUP
OUP
ADD
MOD
LST
InterFreqHoA1Thd Interfreq A1 RSRQ INTERFREQHOGR
InterFreqHoGroup eNodeB INTERFREQHOGR
INTERFREQHOGR
Rsrq threshold OUP
OUP
OUP
ADD
MOD
LST
InterFreqHoA2Thd Interfreq A2 RSRP INTERFREQHOGR
InterFreqHoGroup eNodeB INTERFREQHOGR
INTERFREQHOGR
Rsrp threshold OUP
OUP
OUP
ADD
MOD
LST
InterFreqHoA2Thd Interfreq A2 RSRQ INTERFREQHOGR
InterFreqHoGroup eNodeB INTERFREQHOGR
INTERFREQHOGR
Rsrq threshold OUP
OUP
OUP
ADD
MOD
LST
Interfreq handover INTERFREQHOGR
InterFreqHoGroup InterFreqHoA4Hyst eNodeB INTERFREQHOGR
INTERFREQHOGR
hysteresis OUP
OUP
OUP
ADD
CoverageBased MOD
LST
InterFreqHoA4Thd INTERFREQHOGR
InterFreqHoGroup Interfreq RSRP eNodeB INTERFREQHOGR
INTERFREQHOGR
Rsrp OUP
threshold OUP
OUP
ADD
CoverageBased MOD
LST
InterFreqHoA4Thd INTERFREQHOGR
InterFreqHoGroup Interfrq RSRQ eNodeB INTERFREQHOGR
INTERFREQHOGR
Rsrq OUP
threshold OUP
OUP
ADD
MOD
LST
InterFreqHoA4Time Interfreq HandOver INTERFREQHOGR
InterFreqHoGroup eNodeB INTERFREQHOGR
INTERFREQHOGR
ToTrig Time to Trigger OUP
OUP
OUP
ADD
Load Based MOD
LST
InterFreqLoadBase INTERFREQHOGR
InterFreqHoGroup Interfreq RSRP eNodeB INTERFREQHOGR
INTERFREQHOGR
dHoA4ThdRsrp OUP
threshold OUP
OUP
ADD
MOD
LST
InterFreqLoadBase Load Based Interfrq INTERFREQHOGR
InterFreqHoGroup eNodeB INTERFREQHOGR
INTERFREQHOGR
dHoA4ThdRsrq RSRQ threshold OUP
OUP
OUP
ADD
Freq Priority Based MOD
LST
FreqPriInterFreqHo INTERFREQHOGR
InterFreqHoGroup Interfreq A1 RSRP eNodeB INTERFREQHOGR
INTERFREQHOGR
A1ThdRsrp OUP
threshold OUP
OUP
Freq Priority Based MOD
LST
FreqPriInterFreqHo
InterFreqHoGroup Interfreq A1 RSRQ eNodeB INTERFREQHOGR
INTERFREQHOGR
A1ThdRsrq
threshold OUP
OUP
LST
INTERFREQHOGR
OUP
ADD
INTERFREQHOGR
OUP
ADD
MOD
InterFreqHoA3Offse INTERFREQHOGR
InterFreqHoGroup Interfreq A3 offset eNodeB INTERFREQHOGR
t OUP
OUP
ADD
MOD
LST
A3InterFreqHoA1T A3 based interfreq INTERFREQHOGR
ADD
InterFreqHoGroup eNodeB INTERFREQHOGR
INTERFREQHOGR
hdRsrp A1 RSRP threshold OUP
INTRAFREQHOGR
OUP
OUP
MOD
OUP
LST
A3InterFreqHoA2T A3 based Interfreq ADD
InterFreqHoGroup eNodeB INTERFREQHOGR
LST
INTERFREQHOGR
hdRsrp A2 RSRP threshold INTRAFREQHOGR
OUP
INTRAFREQHOGR
OUP
OUP
LST
OUP
IntraFreqHoGroup LocalCellId Local cell identity eNodeB LST
INTERFREQHOGR
MOD
INTRAFREQHOGR
OUP
ADD
INTRAFREQHOGR
IntraFreqHoGroupI Intrafreq handover OUP
INTRAFREQHOGR
OUP
IntraFreqHoGroup eNodeB
d group ID MOD
OUP
RMV
ADD
INTRAFREQHOGR
MOD
Intrafreq handover INTRAFREQHOGR
IntraFreqHoGroup IntraFreqHoA3Hyst eNodeB INTRAFREQHOGR
OUP
INTRAFREQHOGR
hysteresis OUP
OUP
RMV
OUP
ADD
MOD
IntraFreqHoA3Offse Intrafreq handover INTRAFREQHOGR
LST
IntraFreqHoGroup eNodeB INTRAFREQHOGR
INTRAFREQHOGR
t offset OUP
INTRAFREQHOGR
OUP
OUP
OUP
MOD
IntraFreqHoA3Time Intrafreq handover ADD
LST
IntraFreqHoGroup eNodeB INTRAFREQHOGR
CNOPERATOR
INTRAFREQHOGR
ToTrig time to trigger
OUP
LST
OUP
LST
CNOPERATOR
CnOperator CnOperatorId CN Operator ID eNodeB ADD
INTRAFREQHOGR
MOD
CNOPERATOR
OUP
CNOPERATOR
MOD
RMV
CnOperator CnOperatorName CN Operator name eNodeB ADD
CNOPERATOR
CNOPERATOR
CNOPERATOR
LST
MOD
CNOPERATOR
CnOperator CnOperatorType CN Operator type eNodeB ADD
CNOPERATOR
CNOPERATOR
LST
Mobile country MOD
CNOPERATOR
CnOperator Mcc eNodeB ADD
code CNOPERATOR
CNOPERATOR
LST
Mobile network ADD
MOD
CnOperator Mnc eNodeB CNOPERATOR
CNOPERATORTA
code CNOPERATOR
LST
LST
CNOPERATORTA
CNOPERATOR
CnOperatorTa TrackingAreaId Tracking area ID eNodeB ADD
MOD
CNOPERATORTA
CNOPERATORTA
MOD
RMV
CnOperatorTa CnOperatorId CN Operator ID eNodeB ADD
CNOPERATORTA
CNOPERATORTA
CNOPERATORTA
LST
MOD
CNOPERATORTA
CnOperatorTa Tac Tracking area code eNodeB
CNOPERATORTA
LST
LST EMC
CNOPERATORTA
Emc CnOperatorId CN Operator ID eNodeB
MOD EMC
Emergency call MOD EMC
Emc EmcEnable eNodeB
enabled switch LST EMC
Emergency call
EmcEnableInLimite MOD EMC
Emc enabled switch in eNodeB
dMode LST EMC
limited mode
EmcDedicatedBear The ARP of EMC MOD EMC
Emc eNodeB
erARP dedicated bearer LST EMC
EmcDefaultBearerA The ARP of EMC MOD
ADD EMC
Emc eNodeB MOD
RP default bearer LST EMC
LICENSESHARING
ENODEBSHARING
ENodeBSharingMo eNodeB sharing POLICY
MODE
ENodeBSharingMod eNodeB LST
de mode LST
LICENSESHARING
ENODEBSHARING
POLICY
MODE
LicenseSharingPolic CnOperatorId CN Operator ID eNodeB
MOD
LICENSESHARING
POLICY
RMV
LICENSESHARING
POLICY
ADD
LICENSESHARING
POLICY
The proportion of MOD
LicenseSharingPolic MaxUserNumRate the maximum eNodeB LICENSESHARING
number of users POLICY
MOD
ADD
S1 reestablish min LST
S1REESTTIMER
S1ReestTimer S1ReestMinTimer eNodeB S1INTERFACE
timer length LICENSESHARING
LST
BLK
MOD
POLICY
S1REESTTIMER
S1 reestablish max S1INTERFACE
S1REESTTIMER
S1ReestTimer S1ReestMaxTimer eNodeB DSP
timer length LST
S1INTERFACE
S1REESTTIMER
MOD
S1Interface S1InterfaceId S1Interface ID eNodeB ADD
S1INTERFACE
S1INTERFACE
RMV
MOD
S1INTERFACE
S1Interface S1SctpLinkId S1 SCTP link ID eNodeB ADD
S1INTERFACE
RST
S1INTERFACE
DSP
S1INTERFACE
MOD
S1Interface CnOperatorId CN Operator ID eNodeB S1INTERFACE
UBL
ADD
S1INTERFACE
S1INTERFACE
DSP
MOD
S1INTERFACE
S1Interface MmeRelease MME Release eNodeB
S1INTERFACE
MOD
DSP
S1INTERFACE
S1INTERFACE
S1Interface S1InterfaceIsBlock S1Interface is block eNodeB
DSP
S1INTERFACE
DSP
S1Interface S1InterfaceState S1Interface state eNodeB
S1INTERFACE
DSP
S1Interface S1SctpLinkState S1 SCTP Link State eNodeB
S1INTERFACE
DSP
S1Interface MmeIsOverLoad MME is overloaded eNodeB
S1INTERFACE
S1InterfaceUserNu S1Interface user DSP
S1Interface eNodeB
m number S1INTERFACE
S1SctpLinkStream S1 SCTP Link DSP
S1Interface eNodeB
Num Stream number S1INTERFACE
DSP
S1Interface MmeName MME name eNodeB
S1INTERFACE
DSP
S1Interface ServedPlmns Served PLMNs eNodeB
S1INTERFACE
DSP
S1Interface ServedGummeis Served GUMMEIs eNodeB
S1INTERFACE
ADD
MME relative X2INTERFACE
DSP
S1Interface RelativeMmeCap eNodeB DSP
capacity S1INTERFACE
X2INTERFACE
MOD
X2Interface X2InterfaceId X2Interface ID eNodeB ADD
X2INTERFACE
X2INTERFACE
RMV
MOD
X2INTERFACE
X2Interface X2SctpLinkId X2 SCTP link ID eNodeB ADD
X2INTERFACE
RST
X2INTERFACE
DSP
X2INTERFACE
MOD
X2Interface CnOperatorId CN Operator ID eNodeB X2INTERFACE
ADD
X2INTERFACE
X2INTERFACE
DSP
TargetENodeBRele Target eNodeB MOD
X2INTERFACE
X2Interface eNodeB ADD
ase release X2INTERFACE
X2INTERFACE
DSP
Automatic removal MOD
X2INTERFACE
X2Interface NoAutoRmvFlag eNodeB
flag X2INTERFACE
DSP
Neighbor eNodeB DSP
X2INTERFACE
X2Interface NbrENodeBId eNodeB
ID X2INTERFACE
Neighbor eNodeB DSP
X2Interface NbrENodeBPlmnId eNodeB
PLMN ID X2INTERFACE
DSP
X2Interface X2InterfaceState X2Interface state eNodeB
X2INTERFACE
MOD DRX
Drx DrxAlgSwitch DRX switch eNodeB
LST DRX
Short-cycle DRX MOD DRX
Drx ShortDrxSwitch eNodeB
switch LST DRX
LongDrxCycleSpeci Special long DRX MOD DRX
Drx eNodeB
al cycle LST DRX
OnDurationTimerSp Special On MOD DRX
Drx eNodeB
ecial Duration timer LST DRX
DrxInactivityTimerS Special DRX MOD DRX
Drx eNodeB
pecial inactivity timer LST DRX
Special short-cycle
SupportShortDrxSp MOD DRX
Drx DRX supported eNodeB
ecial LST DRX
indication
ShortDrxCycleSpeci Special short DRX MOD DRX
Drx eNodeB
al cycle LST DRX
DrxShortCycleTimer Special DRX short ADD
MOD DRX
Drx eNodeB EXTENDEDQCI
Special cycle timer LST DRX
LST
Extended QoS EXTENDEDQCI
ExtendedQci ExtendedQci eNodeB ADD
Class Identifier MOD
EXTENDEDQCI
EXTENDEDQCI
MOD
RMV
ExtendedQci ServiceType Service type eNodeB ADD
EXTENDEDQCI
EXTENDEDQCI
EXTENDEDQCI
LST
Uplink scheduling MOD
EXTENDEDQCI
ExtendedQci UlschPriorityFactor eNodeB ADD
priority factor EXTENDEDQCI
EXTENDEDQCI
LST
Downlink
MOD
EXTENDEDQCI
ExtendedQci DlschPriorityFactor scheduling priority eNodeB ADD
EXTENDEDQCI
factor EXTENDEDQCI
LST
MOD
EXTENDEDQCI
ExtendedQci UlMinGbr Uplink MinGBR eNodeB ADD
EXTENDEDQCI
EXTENDEDQCI
LST
MOD
EXTENDEDQCI
ExtendedQci DlMinGbr Downlink MinGBR eNodeB ADD
EXTENDEDQCI
EXTENDEDQCI
LST
PreAllocationWeigh Pre-allocation MOD
EXTENDEDQCI
ExtendedQci eNodeB ADD
t weight EXTENDEDQCI
EXTENDEDQCI
LST
InterRatPolicyCfgGr InterRAT policy MOD
EXTENDEDQCI
ExtendedQci eNodeB ADD
oupId config group ID EXTENDEDQCI
EXTENDEDQCI
LST
MOD
EXTENDEDQCI
ExtendedQci PrioritisedBitRate Prioritised bit rate eNodeB ADD
EXTENDEDQCI
EXTENDEDQCI
LST
LogicalChannelPrio Logical channel MOD
EXTENDEDQCI
ExtendedQci eNodeB ADD
rity priority EXTENDEDQCI
EXTENDEDQCI
LST
RlcPdcpParaGroupI RLC PDCP MOD
EXTENDEDQCI
ADD
ExtendedQci eNodeB ADD
d parameter group ID EXTENDEDQCI
INTERRATPOLICY
EXTENDEDQCI
LST
CFGGROUP
MOD
ExtendedQci FreeUserFlag Free user flag eNodeB EXTENDEDQCI
LST
EXTENDEDQCI
INTERRATPOLICY
LST
InterRatPolicyCfgGr InterRAT policy CFGGROUP
EXTENDEDQCI
InterRatPolicyCfgGr eNodeB
oupId config group ID MOD
INTERRATPOLICY
CFGGROUP
RMV
INTERRATPOLICY
CFGGROUP
ADD
INTERRATPOLICY
CFGGROUP
ADD
MOD
UTRAN handover INTERRATPOLICY
InterRatPolicyCfgGr UtranHoCfg eNodeB INTERRATPOLICY
policy Configuration CFGGROUP
CFGGROUP
ADD
GERAN GSM MOD
LST
InterRatPolicyCfgGr GeranGsmHoCfg handover policy eNodeB INTERRATPOLICY
INTERRATPOLICY
INTERRATPOLICY
CFGGROUP
Configuration CFGGROUP
CFGGROUP
ADD
GERAN GPRS MOD
LST
GeranGprsEdgeHo INTERRATPOLICY
InterRatPolicyCfgGr EDGE handover eNodeB INTERRATPOLICY
INTERRATPOLICY
Cfg CFGGROUP
policy Configuration CFGGROUP
CFGGROUP
ADD
CDMA2000 1XRTT MOD
LST
InterRatPolicyCfgGr Cdma1xRttHoCfg handover policy eNodeB INTERRATPOLICY
INTERRATPOLICY
INTERRATPOLICY
CFGGROUP
Configuration CFGGROUP
CFGGROUP
ADD
CDMA2000 HRPD MOD
LST
InterRatPolicyCfgGr CdmaHrpdHoCfg handover policy eNodeB INTERRATPOLICY
INTERRATPOLICY
INTERRATPOLICY
CFGGROUP
Configuration CFGGROUP
CFGGROUP
ADD
MOD
LST
InterRatPolicyCfgGr NoHoFlag No handover flag eNodeB INTERRATPOLICY
ADD
INTERRATPOLICY
INTERRATPOLICY
CFGGROUP
RLCPDCPPARAGR
CFGGROUP
CFGGROUP
MOD
OUP
LST
InterRatPolicyCfgGr NoFastAnrFlag No fast ANR flag eNodeB INTERRATPOLICY
LST
INTERRATPOLICY
CFGGROUP
RLCPDCPPARAGR
CFGGROUP
ADD
RlcPdcpParaGroupI RLC PDCP LST
OUP
RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB INTERRATPOLICY
d parameter group ID MOD
OUP
CFGGROUP
ADD
RLCPDCPPARAGR
MOD
RlcPdcpParaGroup DiscardTimer Discard timer eNodeB RLCPDCPPARAGR
OUP
RLCPDCPPARAGR
OUP
RMV
OUP
ADD
MOD
RLC-UM or RLC- RLCPDCPPARAGR
LST
RlcPdcpParaGroup RlcMode eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
AM mode OUP
RLCPDCPPARAGR
OUP
OUP
OUP
ADD
MOD
UeMaxRetxThresho MaxretxThreshold LST
RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
ld for UE OUP
OUP
OUP
ADD
MOD
LST
ENodeBMaxRetxTh MaxRetxThreshold RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
reshold for eNodeB OUP
OUP
OUP
ADD
MOD
LST
RlcPdcpParaGroup UePollByte PollByte for UE eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
RLCPDCPPARAGR
OUP
OUP
OUP
ADD
MOD
LST
PollByte for RLCPDCPPARAGR
RlcPdcpParaGroup ENodeBPollByte eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
eNodeB OUP
OUP
OUP
ADD
MOD
LST
RlcPdcpParaGroup UePollPdu PollPdu for UE eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
RLCPDCPPARAGR
OUP
OUP
OUP
ADD
MOD
LST
RlcPdcpParaGroup ENodeBPollPdu PollPdu for eNodeB eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
RLCPDCPPARAGR
OUP
OUP
OUP
ADD
MOD
LST
UePollRetransmitTi Poll retransmit timer RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
mer for UE OUP
OUP
OUP
ADD
MOD
LST
ENodeBPollRetrans Poll retransmit timer RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
mitTimer for eNodeB OUP
OUP
OUP
ADD
MOD
LST
UeStatusProhibitTi Status prohibit timer RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
mer for UE OUP
OUP
OUP
ADD
MOD
LST
ENodeBStatusProhi Status prohibit timer RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
bitTimer for eNodeB OUP
OUP
OUP
ADD
MOD
LST
UeAmReorderingTi AM reordering timer RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
mer for UE OUP
OUP
OUP
ADD
MOD
LST
ENodeBAmReorder AM reordering timer RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
ingTimer for eNodeB OUP
OUP
OUP
MOD
LST
RlcPdcpParaGroup PdcpSnSize UM PDCP-SN size eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
OUP
OUP
LST
RLCPDCPPARAGR
OUP
ADD
RLCPDCPPARAGR
OUP
ADD
MOD
RlcPdcpParaGroup UlRlcSnSize Uplink RLC-Sn size eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
OUP
OUP
ADD
MOD
Downlink RLC-SN LST
RLCPDCPPARAGR
RlcPdcpParaGroup DlRlcSnSize eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
size OUP
OUP
OUP
ADD
MOD
LST
UeUmReorderingTi UM reordering timer RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
mer for UE OUP
OUP
OUP
ADD
MOD
LST
ENodeBUmReorder UM reordering timer RLCPDCPPARAGR
RlcPdcpParaGroup eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
ingTimer for eNodeB OUP
OUP
OUP
AM PDCP status MOD
LST
RlcPdcpParaGroup PdcpStatusRptReq report required eNodeB RLCPDCPPARAGR
RLCPDCPPARAGR
indication OUP
LST
OUP
QoS Class LST
STANDARDQCI
StandardQci Qci eNodeB RLCPDCPPARAGR
Indication MOD
MOD
OUP
STANDARDQCI
STANDARDQCI
StandardQci UlschPriorityFactor Ulsch priority factor eNodeB
LST
MOD
STANDARDQCI
STANDARDQCI
StandardQci DlschPriorityFactor Dlsch priority factor eNodeB
LST
MOD
STANDARDQCI
STANDARDQCI
StandardQci UlMinGbr Uplink MinGBR eNodeB
LST
MOD
STANDARDQCI
STANDARDQCI
StandardQci DlMinGbr Downlink MinGBR eNodeB
LST
MOD
STANDARDQCI
PreAllocationWeigh Pre-allocation STANDARDQCI
StandardQci eNodeB
t weight LST
MOD
STANDARDQCI
InterRatPolicyCfgGr InterRAT policy STANDARDQCI
StandardQci eNodeB
oupId config group ID LST
MOD
STANDARDQCI
RlcPdcpParaGroupI RLC PDCP STANDARDQCI
StandardQci eNodeB
d parameter group ID LST
MOD
STANDARDQCI
STANDARDQCI
StandardQci PrioritisedBitRate Prioritised bit rate eNodeB
LST
MOD
STANDARDQCI
LogicalChannelPrio Logical channel STANDARDQCI
StandardQci eNodeB MOD
rity priority LST
ALGODEFAULTPA
STANDARDQCI
Default doppler RA
AlgoDefaultPara DefDopplerLevel eNodeB MOD
level LST
MIMOADAPTIVEPA
ALGODEFAULTPA
MimoAdaptiveSwitc MIMO adaptive RACFG
RA
MimoAdaptiveParaCf eNodeB MOD
h switch LST
MIMOADAPTIVEPA
MIMOADAPTIVEPA
RACFG
RACFG
MimoAdaptiveParaCfFixedMimoMode Fixed MIMO mode eNodeB
LST
MOD
MIMOADAPTIVEPA
GAP measurement HOMEASCOMM
RACFG
HoMeasComm GapPatternType eNodeB
pattern LST
MOD
HOMEASCOMM
EutranFilterCoeffRs EUTRAN RSRP HOMEASCOMM
HoMeasComm eNodeB
rp filter coefficient LST
MOD
HOMEASCOMM
EutranFilterCoeffRs EUTRAN RSRQ HOMEASCOMM
HoMeasComm eNodeB
rq filter coefficient LST
MOD
HOMEASCOMM
GERAN filter HOMEASCOMM
HoMeasComm GeranFilterCoeff eNodeB
coefficient LST
MOD
HOMEASCOMM
HOMEASCOMM
HoMeasComm SMeasureInd SMeasureInd eNodeB
LST
HOMEASCOMM
MOD
HOMEASCOMM
HoMeasComm SMeasure SMeasure eNodeB
LST
MOD
HOMEASCOMM
HOMEASCOMM
HoMeasComm SpeedDepParaInd SpeedDependInd eNodeB
LST
MOD
HOMEASCOMM
TCRmax in HOMEASCOMM
HoMeasComm TcrMaxConnMode eNodeB
connected mode LST
MOD
HOMEASCOMM
TcrMaxHystConnM TCRmaxHyst in HOMEASCOMM
HoMeasComm eNodeB
ode connected mode LST
MOD
HOMEASCOMM
NcrMediumConnMo NCR Medium in HOMEASCOMM
HoMeasComm eNodeB
de connected mode LST
MOD
HOMEASCOMM
NCR High in HOMEASCOMM
HoMeasComm NcrHighConnMode eNodeB
connected mode LST
TTT Scaling factor MOD
HOMEASCOMM
for Medium mobility HOMEASCOMM
HoMeasComm TttSfMedium eNodeB
state in connected LST
TTT
modeScaling factor MOD
HOMEASCOMM
for High mobility HOMEASCOMM
HoMeasComm TttSfHigh eNodeB
state in connected LST
mode MOD
HOMEASCOMM
UtranFilterCoeffRsc UTRAN RSCP filter HOMEASCOMM
HoMeasComm eNodeB
p coefficient LST
MOD
HOMEASCOMM
UtranFilterCoeffEcn UTRAN ECN0 filter HOMEASCOMM
HoMeasComm eNodeB MOD
0 coefficient LST
INTERRATHOCOM
HOMEASCOMM
InterRatHoMaxRprt Max report cell M
InterRatHoComm eNodeB MOD
Cell number LST
INTERRATHOCOM
INTERRATHOCOM
InterRatHoRprtAmo Measurement M
M
InterRatHoComm eNodeB MOD
unt report amount LST
INTERRATHOCOM
INTERRATHOCOM
Geran
InterRatHoGeranRp M
M
InterRatHoComm measurement eNodeB MOD
rtInterval LST
report interval INTERRATHOCOM
INTERRATHOCOM
InterRatHoUtranB1 Utran measurement M
M
InterRatHoComm eNodeB MOD
MeasQuan trigger quantity LST
INTERRATHOCOM
INTERRATHOCOM
UTRAN FDD
InterRatHoUtranRpr M
M
InterRatHoComm measurement eNodeB MOD
tInterval LST
report interval INTERRATHOCOM
CDMA20001XRTT INTERRATHOCOM
InterRatHoCdma1x M
M
InterRatHoComm measurement eNodeB MOD
RttB1MeasQuan LST
trigger quantity INTERRATHOCOM
CDMA20001XRTT INTERRATHOCOM
InterRatCdma1xRtt M
M
InterRatHoComm measurement eNodeB MOD
RprtInterval LST
report interval INTERRATHOCOM
CDMA2000HRPD INTERRATHOCOM
InterRatHoCdmaHr M
M
InterRatHoComm measurement eNodeB MOD
pdB1MeasQuan LST
trigger quantity INTERRATHOCOM
CDMA2000HRPD INTERRATHOCOM
InterRatCdmaHrpd M
M
InterRatHoComm measurement eNodeB MOD
RprtInterval LST
report interval INTERRATHOCOM
INTERRATHOCOM
InterRatHoA1A2Tri A1A2 measurement M
M
InterRatHoComm eNodeB MOD
gQuan trigger quantity LST
INTRARATHOCOM
INTERRATHOCOM
IntraRatHoMaxRprt Max report cell M
M
IntraRatHoComm eNodeB MOD
Cell number LST
INTRARATHOCOM
INTRARATHOCOM
IntraRatHoRprtAmo Measurement M
M
IntraRatHoComm eNodeB MOD
unt report amount LST
INTRARATHOCOM
INTRARATHOCOM
IntraFreqHoA3Trig A3 measurement M
M
IntraRatHoComm eNodeB
Quan trigger quantity LST
INTRARATHOCOM
M
MOD
INTRARATHOCOM
IntraFreqHoA3Rprt A3 measurement M
IntraRatHoComm eNodeB MOD
Quan report quantity LST
INTRARATHOCOM
INTRARATHOCOM
Intrafreq
IntraFreqHoRprtInte M
M
IntraRatHoComm measurement eNodeB MOD
rval LST
report interval INTRARATHOCOM
INTRARATHOCOM
InterFreqHoA4Rprt Measurement A4 M
M
IntraRatHoComm eNodeB MOD
Quan report quantity LST
INTRARATHOCOM
INTRARATHOCOM
Interfreq
InterFreqHoRprtInte M
M
IntraRatHoComm measurement eNodeB MOD
rval LST
report interval INTRARATHOCOM
INTRARATHOCOM
InterFreqHoA1A2Tri A1A2 Measurement M
M
IntraRatHoComm eNodeB MOD
gQuan trigger quantity LST
INTRARATHOCOM
INTRARATHOCOM
A1 Measurement
FreqPriInterFreqHo M
M
IntraRatHoComm trigger quantity of eNodeB MOD
A1TrigQuan LST
Freq Priority INTRARATHOCOM
INTRARATHOCOM
InterFreqHoA4Trig A4 Measurement M
M
IntraRatHoComm eNodeB
Quan trigger quantity LST
LST
INTRARATHOCOM
CSFALLBACKHO
M
CSFallBackHo LocalCellId Local cell identity eNodeB
MOD
MOD
CSFALLBACKHO
CSFB Utran
CsfbHoUtranTimeT CSFALLBACKHO
CSFallBackHo EventB1 Time To eNodeB
oTrig LST
Trig MOD
CSFB Geran CSFALLBACKHO
CsfbHoGeranTimeT CSFALLBACKHO
CSFallBackHo EventB1 Time To eNodeB
oTrig LST
Trig MOD
CSFB CDMA CSFALLBACKHO
CsfbHoCdmaTimeT CSFALLBACKHO
CSFallBackHo EventB1 Time To eNodeB
oTrig LST
Trig MOD
CSFB UTRAN CSFALLBACKHO
CsfbHoUtranB1Thd CSFALLBACKHO
CSFallBackHo EventB1 RSCP eNodeB
Rscp LST
Trigger Threshold MOD
CSFB UTRAN CSFALLBACKHO
CsfbHoUtranB1Thd CSFALLBACKHO
CSFallBackHo EventB1 ECN0 eNodeB
Ecn0 LST
Trigger Threshold MOD
CSFB GERAN CSFALLBACKHO
CsfbHoGeranB1Th CSFALLBACKHO
CSFallBackHo EventB1 Trigger eNodeB
d LST
Threshold MOD
CSFB CDMA2000 CSFALLBACKHO
CsfbHoCdmaB1Thd CSFALLBACKHO
CSFallBackHo EventB1 Trigger eNodeB
Ps LST
Threshold
CSFALLBACKHO
LST CELLACBAR
CellAcBar LocalCellId Local cell identity eNodeB
MOD CELLACBAR
AC barring
AcBarringInfoCfgIn MOD CELLACBAR
CellAcBar information eNodeB
d LST CELLACBAR
configure indicator
AcBarringForEmerg Emergency call MOD CELLACBAR
CellAcBar eNodeB
ency barring state LST CELLACBAR
AC barring for
AcBarringForMoDat MOD CELLACBAR
CellAcBar mobile data eNodeB
aCfgInd LST CELLACBAR
configure indicator
Access probability
AcBarringFactorFor MOD CELLACBAR
CellAcBar factor for originating eNodeB
Call LST CELLACBAR
call
Mean access
MOD CELLACBAR
CellAcBar AcBarTimeForCall barring time for eNodeB
LST CELLACBAR
originating call
AC11 barring state MOD CELLACBAR
CellAcBar AC11BarforCall eNodeB
for originating call LST CELLACBAR
AC12 barring state MOD CELLACBAR
CellAcBar AC12BarforCall eNodeB
for originating call LST CELLACBAR
AC13 barring state MOD CELLACBAR
CellAcBar AC13BarforCall eNodeB
for originating call LST CELLACBAR
AC14 barring state MOD CELLACBAR
CellAcBar AC14BarforCall eNodeB
for originating call LST CELLACBAR
AC15 barring state MOD CELLACBAR
CellAcBar AC15BarforCall eNodeB
for originating call LST CELLACBAR
AC barring for
AcBarringForMoSig MOD CELLACBAR
CellAcBar mobile signal eNodeB
CfgInd LST CELLACBAR
configure indicator
AcBarringFactorFor Access probability MOD CELLACBAR
CellAcBar eNodeB
Sig factor for signalling LST CELLACBAR
Mean access
MOD CELLACBAR
CellAcBar AcBarTimeForSig barring time for eNodeB
LST CELLACBAR
signalling
AC11 barring state MOD CELLACBAR
CellAcBar AC11BarForSig eNodeB
for signalling LST CELLACBAR
AC12 barring state MOD CELLACBAR
CellAcBar AC12BarForSig eNodeB
for signalling LST CELLACBAR
AC13 barring state MOD CELLACBAR
CellAcBar AC13BarForSig eNodeB
for signalling LST CELLACBAR
AC14 barring state MOD CELLACBAR
CellAcBar AC14BarForSig eNodeB
for signalling LST CELLACBAR
AC15 barring state MOD CELLACBAR
CellAcBar AC15BarForSig eNodeB
for signalling LST CELLACBAR
LST CELLACCESS
CellAccess LocalCellId Local cell identity eNodeB MOD
CELLACCESS
MOD
CellAccess CellBarred Cell barring state eNodeB CELLACCESS
LST CELLACCESS
MOD
Cell reserved for
CellAccess CellReservedExt eNodeB CELLACCESS
extension
LST CELLACCESS
Intra-frequency MOD
CellAccess IntraFreqResel reselection eNodeB CELLACCESS
indication LST CELLACCESS
MOD
Plmn Broadcast
CellAccess BroadcastMode eNodeB CELLACCESS
Mode
LST CELLACCESS
MOD
Plmn Round
CellAccess RoundPeriod eNodeB CELLACCESS
Broadcast Period
LST CELLACCESS
ADD CELLOP
LST CELLOP
CellOp LocalCellId Local cell identity eNodeB
MOD CELLOP
ADD
RMV CELLOP
CELLOP
Tracking area LST CELLOP
CellOp TrackingAreaId eNodeB
identity MOD CELLOP
RMV CELLOP
ADD CELLOP
Cell reserved for
CellOp CellReservedForOp eNodeB MOD CELLOP
operator
LST CELLOP
ADD CELLOP
Operator uplink RB
CellOp OpUlRbUsedRatio eNodeB MOD CELLOP
used ratio
LST CELLOP
ADD CELLOP
Operator downlink
CellOp OpDlRbUsedRatio eNodeB MOD CELLOP
RB used ratio
LST CELLOP
LST CELLRESEL
CellResel LocalCellId Local cell identity eNodeB
MOD CELLRESEL
Hysteresis value for MOD CELLRESEL
CellResel Qhyst eNodeB
ranking criteria LST CELLRESEL
Speed-dependent
SpeedDepReselCfg reselection MOD CELLRESEL
CellResel eNodeB
Ind parameter LST CELLRESEL
The duration
configure for
indicator
evaluating criteria MOD CELLRESEL
CellResel TEvaluation eNodeB
to enter
The mobility
additional LST CELLRESEL
states
duration for
MOD CELLRESEL
CellResel THystNormal evaluating criteria eNodeB
LST CELLRESEL
to
Theenter normal
number of cell
mobility state
NCellChangeMediu changes to enter MOD CELLRESEL
CellResel eNodeB
m medium mobility LST CELLRESEL
state
The number of cell
MOD CELLRESEL
CellResel NCellChangeHigh changes to enter eNodeB
LST CELLRESEL
high mobility state
Additional
hysteresis applied MOD CELLRESEL
CellResel QHystSfMedium eNodeB
in medium mobility LST CELLRESEL
Additional
state to q-Hyst
hysteresis applied MOD CELLRESEL
CellResel QHystSfHigh eNodeB
in high mobility
Threshold for LST CELLRESEL
state to q-Hyst
EUTRAN inter-
SNonIntraSearchCf MOD CELLRESEL
CellResel frequency and inter- eNodeB
gInd LST CELLRESEL
RAT measurements
Threshold for
configure inter-
EUTRAN indicator MOD CELLRESEL
CellResel SNonIntraSearch eNodeB
frequency and inter- LST CELLRESEL
RAT measurements
Serving frequency
MOD CELLRESEL
CellResel ThrshServLow lower priority eNodeB
LST CELLRESEL
threshold
Cell reselection MOD CELLRESEL
CellResel CellReselPriority eNodeB
priority LST CELLRESEL
Minimum required MOD CELLRESEL
CellResel QRxLevMin eNodeB
RX level LST CELLRESEL
Ue max power
MOD CELLRESEL
CellResel PMaxCfgInd allowed configure eNodeB
LST CELLRESEL
indicator
Max transmit power MOD CELLRESEL
CellResel PMax eNodeB
allowed LST CELLRESEL
Threshold for intra
frequency MOD CELLRESEL
CellResel SIntraSearchCfgInd eNodeB
measurements LST CELLRESEL
configure indicator
Threshold for intra
MOD CELLRESEL
CellResel SIntraSearch frequency eNodeB
LST CELLRESEL
measurements
Measurement
MeasBandWidthCfg MOD CELLRESEL
CellResel bandwidth eNodeB
Ind LST CELLRESEL
configure indicator
Measurement MOD CELLRESEL
CellResel MeasBandWidth eNodeB
bandwidth LST CELLRESEL
Cell reselection
MOD CELLRESEL
CellResel TReselEutran timer value for eNodeB
LST CELLRESEL
EUTRAN
Speed state scale
SpeedStateSfCfgIn MOD CELLRESEL
CellResel factor configure eNodeB
d LST CELLRESEL
indicatorfactor of
Scaling
TReselEutranSfMe TReselEutra in MOD CELLRESEL
CellResel eNodeB
dium medium mobility LST CELLRESEL
state factor of
Scaling
TReselEutranSfHig MOD CELLRESEL
CellResel TReselEutra in high eNodeB
h LST CELLRESEL
mobility state
MOD
ADD CELLRESEL
CellResel NeighCellConfig Neighbor cell config eNodeB
LST CELLRESEL
CELLRESELCDMA
PresenceAntennaP Presence antenna 2000
MOD CELLRESEL
CellResel eNodeB LST
ort1 port1 LST CELLRESEL
CELLRESELCDMA
ADD
2000
CELLRESELCDMA
CellReselCdma2000 LocalCellId Local cell identity eNodeB
MOD
2000
System time ADD
CELLRESELCDMA
MOD
CellReselCdma2000 SysTimeCfgInd information eNodeB CELLRESELCDMA
2000
CELLRESELCDMA
configure 2000
RMV
CDMA andindicator
EUTRA 2000
ADD
MOD
CELLRESELCDMA
LST
network CELLRESELCDMA
CellReselCdma2000 CdmaEutraSyn eNodeB CELLRESELCDMA
2000
CELLRESELCDMA
synchronised 2000
2000
2000
ADD
indicator
CDMA search MOD
SearchWndSizeCfg LST
CELLRESELCDMA
CellReselCdma2000 window size eNodeB CELLRESELCDMA
CELLRESELCDMA
Ind 2000
configure indicator 2000
2000
ADD
MOD
LST
CellReselCdma2000 SearchWndSize Search window size eNodeB CELLRESELCDMA
CELLRESELCDMA
CELLRESELCDMA
2000
2000
2000
ADD
MOD
LST
HRPD parameters CELLRESELCDMA
CellReselCdma2000 HrpdParamCfgInd eNodeB CELLRESELCDMA
CELLRESELCDMA
configure indicator 2000
2000
2000
ADD
HRPD cell MOD
LST
HrpdCellReselectP CELLRESELCDMA
CellReselCdma2000 reselection eNodeB CELLRESELCDMA
CELLRESELCDMA
aramCfgInd 2000
configure indicator 2000
2000
ADD
MOD
LST
HrpdPreRegistAllow HRPD pre-regist CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
ed allowed indicator 2000
2000
2000
ADD
MOD
LST
HrpdPreRegistZone HRPD pre-regist CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
Id zone identity 2000
2000
2000
ADD
HRPD second pre- MOD
LST
HrpdSecondPreRe CELLRESELCDMA
CellReselCdma2000 regist zone 0 eNodeB CELLRESELCDMA
CELLRESELCDMA
gistZoneId0Ind 2000
configure indicator 2000
2000
ADD
HRPD secondary MOD
LST
HrpdSecPreRegistZ CELLRESELCDMA
CellReselCdma2000 pre-regist zone eNodeB CELLRESELCDMA
CELLRESELCDMA
oneId0 2000
identity 0 2000
2000
ADD
HRPD second pre- MOD
LST
HrpdSecondPreRe CELLRESELCDMA
CellReselCdma2000 regist zone 1 eNodeB CELLRESELCDMA
CELLRESELCDMA
gistZoneId1Ind 2000
configure indicator 2000
2000
ADD
HRPD secondary MOD
LST
HrpdSecPreRegistZ CELLRESELCDMA
CellReselCdma2000 pre-regist zone eNodeB CELLRESELCDMA
CELLRESELCDMA
oneId1 2000
identity 1 2000
2000
ADD
MOD
LST
Cell reselection CELLRESELCDMA
CellReselCdma2000 TreselectionHrpd eNodeB CELLRESELCDMA
CELLRESELCDMA
timer for HRPD 2000
2000
2000
ADD
Speed state scale MOD
LST
SpeedStateSfCfgIn CELLRESELCDMA
CellReselCdma2000 factor configure eNodeB CELLRESELCDMA
CELLRESELCDMA
d 2000
indicatorfactor of
Scaling 2000
2000
ADD
MOD
LST
TReselCdmaHrpdSf TReselCdmaHrpd CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
High in high mobility 2000
Scaling 2000
state factor of 2000
ADD
MOD
TReselCdmaHrpdSf TReselCdmaHrpd LST
CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
Medium in medium mobility 2000
2000
2000
ADD
state MOD
1XRTT parameters LST
CELLRESELCDMA
CellReselCdma2000 Cdma1XrttCfgInd eNodeB CELLRESELCDMA
CELLRESELCDMA
configure indicator 2000
1XRTT csfb- 2000
2000
ADD
MOD
LST
Cdma1XrttCsfbReg registration CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
CfgInd parameters 2000
2000
2000
ADD
configure indicator MOD
Cdma1XrttCsfbReg 1XRTT system LST
CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
Sid identity 2000
2000
2000
MOD
LST
Cdma1XrttCsfbReg 1XRTT network
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
Nid identity
2000
2000
LST
CELLRESELCDMA
2000
ADD
CELLRESELCDMA
2000
1XRTT multiple ADD
MOD
Cdma1XrttCsfbReg CELLRESELCDMA
CellReselCdma2000 system identity eNodeB CELLRESELCDMA
MultiSidInd 2000
storage indicator 2000
ADD
1XRTT multiple MOD
LST
Cdma1XrttCsfbReg CELLRESELCDMA
CellReselCdma2000 network identity eNodeB CELLRESELCDMA
CELLRESELCDMA
MultiNidInd 2000
storage indicator 2000
2000
ADD
1XRTT home MOD
LST
Cdma1XrttCsfbReg CELLRESELCDMA
CellReselCdma2000 registration eNodeB CELLRESELCDMA
CELLRESELCDMA
HomeRegInd 2000
indicatorsystem
1XRTT 2000
2000
ADD
MOD
LST
Cdma1XrttCsfbReg identity roamer CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
FrgnSidRegInd registration 2000
1XRTT 2000
indicatornetwork 2000
ADD
MOD
Cdma1XrttCsfbReg identity roamer LST
CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
FrgnNidRegInd registration 2000
2000
2000
ADD
indicator
1XRTT parameter MOD
Cdma1XrttCsfbReg LST
CELLRESELCDMA
CellReselCdma2000 change registration eNodeB CELLRESELCDMA
CELLRESELCDMA
ParamRegInd 2000
indicator 2000
2000
ADD
1XRTT power up MOD
LST
Cdma1XrttCsfbReg CELLRESELCDMA
CellReselCdma2000 registration eNodeB CELLRESELCDMA
CELLRESELCDMA
PowerUpRegInd 2000
indicator 2000
2000
ADD
MOD
LST
Cdma1XrttCsfbReg 1XRTT registration CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
RegPeriod period 2000
2000
2000
ADD
MOD
LST
Cdma1XrttCsfbReg 1XRTT registration CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
RegZone zone 2000
2000
2000
ADD
1XRTT number of MOD
LST
Cdma1XrttCsfbReg CELLRESELCDMA
CellReselCdma2000 registration zones eNodeB CELLRESELCDMA
CELLRESELCDMA
TotalZone 2000
to be retained 2000
2000
ADD
MOD
LST
Cdma1XrttCsfbReg 1XRTT zone timer CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
ZoneTimer length 2000
1XRTT state of long 2000
2000
ADD
MOD
LST
Cdma1XrttLongCod code generation CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
eStateCfgInd registers configure 2000
2000
2000
ADD
indicatorr
1XRTT state of long MOD
Cdma1XrttLongCod LST
CELLRESELCDMA
CellReselCdma2000 code generation eNodeB CELLRESELCDMA
CELLRESELCDMA
eState 2000
registers 2000
2000
ADD
1XRTT cell MOD
LST
Cdma1XrttCellRese CELLRESELCDMA
CellReselCdma2000 reselection eNodeB CELLRESELCDMA
CELLRESELCDMA
lCfgInd 2000
configure indicator 2000
2000
ADD
MOD
LST
Cdma1XrttTreselect Cell reselection CELLRESELCDMA
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
ion timer for 1XRTT 2000
2000
2000
ADD
1XRTT speed state MOD
LST
Cdma1XrttSpeedSt CELLRESELCDMA
CellReselCdma2000 scale factors eNodeB CELLRESELCDMA
CELLRESELCDMA
ateCfgInd 2000
configure indicator 2000
2000
ADD
MOD
LST
Cdma1XrttSfMediu 1XRTT medium CELLRESELCDMA
ADD
CellReselCdma2000 eNodeB CELLRESELCDMA
CELLRESELCDMA
m speed scale factor 2000
CELLRESELGERA
2000
2000
MOD
N
LST
1XRTT high speed
CellReselCdma2000 Cdma1XrttSfHigh eNodeB CELLRESELCDMA
LST
CELLRESELCDMA
scale factor
2000
CELLRESELGERA
2000
ADD
LST
N
CELLRESELGERA
CellReselGeran LocalCellId Local cell identity eNodeB CELLRESELCDMA
MOD
N
Cell reselection 2000
ADD
CELLRESELGERA
MOD
CellReselGeran TReselGeran timer value for eNodeB CELLRESELGERA
N
CELLRESELGERA
GERAN N
RMV
N
Speed state scale ADD
MOD
SpeedStateSfCfgIn CELLRESELGERA
LST
CellReselGeran factor configure eNodeB CELLRESELGERA
CELLRESELGERA
d N
CELLRESELGERA
indicatorfactor of N
N
Scaling N
ADD
MOD
LST
TReselGeranSfMed TReselGeran in CELLRESELGERA
CellReselGeran eNodeB CELLRESELGERA
CELLRESELGERA
ium medium mobility N
N
N
state factor of
Scaling MOD
LST
CellReselGeran TReselGeranSfHigh TReselGeran in eNodeB CELLRESELGERA
CELLRESELGERA
high mobility state N
N
LST
CELLRESELGERA
N
ADD
CELLRESELUTRA
N
LST
CELLRESELUTRA
ADD
N
CELLRESELUTRA
CellReselUtran LocalCellId Local cell identity eNodeB
MOD
N
Cell reselection ADD
CELLRESELUTRA
MOD
CellReselUtran TReselUtran timer value for eNodeB CELLRESELUTRA
N
CELLRESELUTRA
UTRAN N
RMV
N
Speed state scale ADD
MOD
SpeedStateSfCfgIn CELLRESELUTRA
LST
CellReselUtran factor configure eNodeB CELLRESELUTRA
CELLRESELUTRA
d N
CELLRESELUTRA
indicatorfactor of N
N
Scaling N
ADD
MOD
LST
TReselUtranSfMedi TReselUtran in CELLRESELUTRA
CellReselUtran eNodeB CELLRESELUTRA
CELLRESELUTRA
um medium mobility N
N
N
state factor of
Scaling MOD
LST
CellReselUtran TReselUtranSfHigh TReselUtran in high eNodeB CELLRESELUTRA
CELLRESELUTRA
mobility state N
N
LST CELLSEL
LST
CellSel LocalCellId Local cell identity eNodeB CELLRESELUTRA
MOD CELLSEL
N
Minimum required MOD CELLSEL
CellSel QRxLevMin eNodeB
RX level LST CELLSEL
Minimum required MOD CELLSEL
CellSel QRxLevMinOffset eNodeB
RX level offset LST CELLSEL
LST CELLSIMAP
CellSiMap LocalCellId Local cell identity eNodeB
MOD CELLSIMAP
SIB mapping SI MOD CELLSIMAP
CellSiMap SiMapSwitch eNodeB
algorithm switch LST CELLSIMAP
MOD CELLSIMAP
CellSiMap Sib2Period SIB2 period eNodeB
LST CELLSIMAP
MOD CELLSIMAP
CellSiMap Sib3Period SIB3 period eNodeB
LST CELLSIMAP
MOD CELLSIMAP
CellSiMap Sib4Period SIB4 period eNodeB
LST CELLSIMAP
MOD CELLSIMAP
CellSiMap Sib5Period SIB5 period eNodeB
LST CELLSIMAP
MOD CELLSIMAP
CellSiMap Sib6Period SIB6 period eNodeB
LST CELLSIMAP
MOD CELLSIMAP
CellSiMap Sib7Period SIB7 period eNodeB
LST CELLSIMAP
MOD CELLSIMAP
CellSiMap Sib8Period SIB8 period eNodeB
LST CELLSIMAP
LST
CELLULPCCOMM
CellUlpcComm LocalCellId Local cell identity eNodeB
MOD
MOD
CELLULPCCOMM
CELLULPCCOMM
CellUlpcComm PassLossCoeff Path loss coefficient eNodeB
LST
MOD
CELLULPCCOMM
CELLULPCCOMM
CellUlpcComm P0NominalPUCCH P0 nominal PUCCH eNodeB
LST
MOD
CELLULPCCOMM
CELLULPCCOMM
CellUlpcComm P0NominalPUSCH P0 nominal PUSCH eNodeB
LST
MOD
CELLULPCCOMM
DeltaFPUCCHForm DeltaF for PUCCH CELLULPCCOMM
CellUlpcComm eNodeB
at1 format 1 LST
MOD
CELLULPCCOMM
DeltaFPUCCHForm DeltaF for PUCCH CELLULPCCOMM
CellUlpcComm eNodeB
at1b format 1b LST
CELLULPCCOMM
MOD
DeltaFPUCCHForm DeltaF for PUCCH CELLULPCCOMM
CellUlpcComm eNodeB
at2 format 2 LST
MOD
CELLULPCCOMM
DeltaFPUCCHForm DeltaF for PUCCH CELLULPCCOMM
CellUlpcComm eNodeB
at2a format 2a LST
MOD
CELLULPCCOMM
DeltaFPUCCHForm DeltaF for PUCCH CELLULPCCOMM
CellUlpcComm eNodeB
at2b format 2b LST
MOD
CELLULPCCOMM
DeltaPreambleMsg Delta preamble CELLULPCCOMM
CellUlpcComm eNodeB
3 value for msg3 LST
LST
CELLULPCCOMM
UETIMERCONST
UeTimerConst LocalCellId Local cell identity eNodeB
MOD
MOD
UETIMERCONST
UETIMERCONST
UeTimerConst T300 Timer 300 eNodeB
LST
MOD
UETIMERCONST
UETIMERCONST
UeTimerConst T301 Timer 301 eNodeB
LST
MOD
UETIMERCONST
UETIMERCONST
UeTimerConst T310 Timer 310 eNodeB
LST
MOD
UETIMERCONST
UETIMERCONST
UeTimerConst T311 Timer 311 eNodeB
LST
MOD
UETIMERCONST
UETIMERCONST
UeTimerConst N311 Constant N311 eNodeB
LST
MOD
ACT CELL
UETIMERCONST
UETIMERCONST
ADD CELL
UeTimerConst N310 Constant N310 eNodeB
LST CELL
BLK
UETIMERCONST
DEA CELL
Cell LocalCellId Local cell identity eNodeB DSP CELL
LST CELL
ADD
MOD CELL
CELL
Cell CellName Cell name eNodeB MOD CELL
RMV CELL
LST
UBL CELL
ADD CELL
CELL
Cell SectorId Sector No. eNodeB MOD CELL
LST CELL
ADD CELL
Cell CsgInd Csg indicator eNodeB MOD CELL
LST CELL
ADD CELL
Uplink cyclic prefix
Cell UlCyclicPrefix eNodeB MOD CELL
length
LST CELL
ADD CELL
Downlink cyclic
Cell DlCyclicPrefix eNodeB MOD CELL
prefix length
LST CELL
ADD CELL
Cell FreqBand Frequency band eNodeB MOD CELL
LST CELL
ADD CELL
Uplink earfcn
Cell UlEarfcnCfgInd eNodeB MOD CELL
indication
LST CELL
ADD CELL
Cell UlEarfcn Uplink earfcn eNodeB MOD CELL
LST CELL
ADD CELL
Cell DlEarfcn Downlink earfcn eNodeB MOD CELL
LST CELL
ADD CELL
Cell UlBandWidth Uplink bandwidth eNodeB MOD CELL
LST CELL
ADD CELL
Cell DlBandWidth Downlink bandwidth eNodeB MOD CELL
LST CELL
ADD CELL
Cell CellId Cell identity eNodeB MOD CELL
LST CELL
ADD CELL
Cell PhyCellId Physical cell identity eNodeB MOD CELL
LST CELL
ADD CELL
AdditionalSpectrum Additional spectrum
Cell eNodeB MOD CELL
Emission emission
LST CELL
Cell CellActiveState Cell active state eNodeB LST CELL

BLK CELL
Cell CellAdminState Cell admin state eNodeB
LST CELL
Cell middle block BLK CELL
Cell CellMidBlkTimer eNodeB
timer LST CELL
ADD CELL
Cell FDD TDD
Cell FddTddInd eNodeB MOD CELL
indication
LST CELL
ADD CELL
SubframeAssignme Subframe
Cell eNodeB MOD CELL
nt assignment
LST CELL
ADD CELL
SpecialSubframePa Special subframe
Cell eNodeB MOD CELL
tterns patterns
LST CELL
ADD CELL
Cell CellSpecificOffset Cell specific offset eNodeB MOD CELL
LST CELL
ADD CELL
Intra frequency
Cell QoffsetFreq eNodeB MOD CELL
offset
LST CELL
ADD CELL
Root sequence
Cell RootSequenceIdx eNodeB MOD CELL
index
LST CELL
ADD CELL
Cell HighSpeedFlag High speed flag eNodeB MOD CELL
LST CELL
ADD CELL
Cell PreambleFmt Preamble format eNodeB MOD CELL
LST CELL
ADD CELL
Cell CellRadius Cell radius eNodeB MOD CELL
LST CELL
Customization ADD CELL
CustomizedBandWi
Cell bandwidth eNodeB MOD CELL
dthCfgInd
configure indicator LST CELL
ADD CELL
CustomizedULBand Customization real
Cell eNodeB MOD CELL
Width uplink bandwith
LST CELL
ADD CELL
CustomizedDLBand Customization real
Cell eNodeB MOD CELL
Width downlink bandwidth
LST CELL
Cell CellState Cell instance state eNodeB DSP CELL

Cell latest avail


Cell CellLatestAvailState eNodeB DSP CELL
state
CellLatestSetupTim Cell latest setup
Cell eNodeB DSP CELL
e time
CellLatestSetupTyp Cell latest setup
Cell eNodeB DSP CELL
e operate type
CellLatestRemoveT Cell latest remove
Cell eNodeB DSP CELL
ime time
CellLatestRemoveT Cell latest remove
Cell eNodeB DSP CELL
ype operate type
CellPowerSaveStat Cell power save
Cell eNodeB DSP CELL
e state

Cell BbiSlot Bbi slot eNodeB DSP CELL

Cell CellTopoType Cell topo type eNodeB DSP CELL

RRU0 subrack
Cell Rru0SubrackNo eNodeB DSP CELL
number
RRU1 subrack
Cell Rru1SubrackNo eNodeB DSP CELL
LST
number
CELLDLICICMCPA
RA
CellDLIcicMcPara LocalCellId Local cell identity eNodeB MOD
MOD
CELLDLICICMCPA
CELLDLICICMCPA
Downlink ICIC
RA
RA
CellDLIcicMcPara ReportInterval measurement eNodeB MOD
LST
report interval CELLDLICICMCPA
Downlink ICIC CELLDLICICMCPA
RA
RA
CellDLIcicMcPara MaxReportCellNum measurement max eNodeB MOD
LST
report cell number CELLDLICICMCPA
DownLink ICIC CELLDLICICMCPA
RA
RA
CellDLIcicMcPara ReportAmount measurement eNodeB MOD
LST
report amount CELLDLICICMCPA
DownLink ICIC CELLDLICICMCPA
RA
RA
CellDLIcicMcPara ReportQuantity measurement eNodeB MOD
LST
report quantity CELLDLICICMCPA
DownLink ICIC CELLDLICICMCPA
RA
RA
CellDLIcicMcPara TriggerQuantity measurement eNodeB MOD
LST
trigger quantity CELLDLICICMCPA
DownLink ICIC CELLDLICICMCPA
RA
RA
CellDLIcicMcPara Hysteresis measurement eNodeB MOD
LST
hysteresis CELLDLICICMCPA
DownLink ICIC CELLDLICICMCPA
RA
RA
CellDLIcicMcPara TimeToTrigger measurement time eNodeB MOD
LST
to trigger CELLDLICICMCPA
CELLDLICICMCPA
Downlink ICIC A3 RA
RA
CellDLIcicMcPara A3Offset eNodeB
offset LST
LST
CELLDLICICMCPA
CELLLOWPOWER
RA
CellLowPower LocalCellId Local cell identity eNodeB
MOD
MOD
CELLLOWPOWER
Low power
CELLLOWPOWER
CellLowPower LowPwrSwitch consumption mode eNodeB
LST
switch MOD
Low power CELLLOWPOWER
CELLLOWPOWER
CellLowPower LowPwrOrder consumption mode eNodeB
LST
order MOD
CELLLOWPOWER
CELLLOWPOWER
CellLowPower StartTime Start time eNodeB
LST
MOD
CELLLOWPOWER
CELLLOWPOWER
CellLowPower StopTime Stop time eNodeB
LST
MOD
CELLLOWPOWER
CellUsedPwrReduc Cell used power CELLLOWPOWER
CellLowPower eNodeB
eTimeLen reduce time length LST
MOD
CELLLOWPOWER
Reference signal
RsPwrReduceTime CELLLOWPOWER
CellLowPower power reduce time eNodeB
Len LST
length MOD
CELLLOWPOWER
RfShutDownTimeLe RF shutdown time CELLLOWPOWER
CellLowPower eNodeB
n length LST
CELLLOWPOWER
MOD
Cell used power CELLLOWPOWER
CellLowPower CellUsedPwrRatio eNodeB
ratio LST
MOD
CELLLOWPOWER
Reference signal CELLLOWPOWER
CellLowPower RsPwrAdjOffset eNodeB
power adjust offset LST
Time length for MOD
CELLLOWPOWER
entering the low CELLLOWPOWER
CellLowPower EnterTimeLen eNodeB
power consumption LST
mode CELLLOWPOWER
LST CELLRACTHD
CellRacThd LocalCellId Local cell identity eNodeB MOD
CELLRACTHD
MOD
Gold service arp
CellRacThd GoldServiceArpThd eNodeB CELLRACTHD
threshold
LST CELLRACTHD
MOD
SilverServiceArpTh Silver service arp
CellRacThd eNodeB CELLRACTHD
d threshold
LST CELLRACTHD
MOD
QCI1 handover
CellRacThd Qci1HoThd eNodeB CELLRACTHD
admission threshold
LST CELLRACTHD
MOD
QCI2 handover
CellRacThd Qci2HoThd eNodeB CELLRACTHD
admission threshold
LST CELLRACTHD
MOD
QCI3 handover
CellRacThd Qci3HoThd eNodeB CELLRACTHD
admission threshold
LST CELLRACTHD
MOD
QCI4 handover
CellRacThd Qci4HoThd eNodeB CELLRACTHD
admission threshold
LST CELLRACTHD
Gold new service MOD
NewGoldServiceOff
CellRacThd admission threshold eNodeB CELLRACTHD
set
offset LST CELLRACTHD
Silver new service MOD
NewSilverServiceOf
CellRacThd admission threshold eNodeB CELLRACTHD
fset
offset LST CELLRACTHD
Copper new service MOD
NewCopperService
CellRacThd admission threshold eNodeB CELLRACTHD
Offset
offset LST CELLRACTHD
MOD
QCI1 congest
CellRacThd Qci1CongThd eNodeB CELLRACTHD
threshold
LST CELLRACTHD
MOD
QCI2 congest
CellRacThd Qci2CongThd eNodeB CELLRACTHD
threshold
LST CELLRACTHD
MOD
QCI3 congest
CellRacThd Qci3CongThd eNodeB CELLRACTHD
threshold
LST CELLRACTHD
MOD
QCI4 congest
CellRacThd Qci4CongThd eNodeB CELLRACTHD
threshold
Gold-level GBR LST CELLRACTHD
MOD
GoldGbrCongPropo service congest
CellRacThd eNodeB CELLRACTHD
rtion scheduler
Silver-level LST CELLRACTHD
proportion GBR MOD
SilverGbrCongProp service congest
CellRacThd eNodeB CELLRACTHD
ortion scheduler
Copper-level LST CELLRACTHD
proportion GBR MOD
CopperGbrCongPro service congest
CellRacThd eNodeB CELLRACTHD
portion scheduler
LST CELLRACTHD
proportion
GBR used resource MOD
GbrRbUsedHighTh
CellRacThd high proportion eNodeB CELLRACTHD
d
threshold LST CELLRACTHD
GBR used resource MOD
CellRacThd GbrRbUsedLowThd low proportion eNodeB CELLRACTHD
threshold LST CELLRACTHD
MOD
CellRacThd LdcMeaArpThd ARP threshold eNodeB CELLRACTHD
LST CELLRACTHD
MOD
Offset for service
CellRacThd CongRelOffset eNodeB CELLRACTHD
congest relieving
LST CELLRACTHD
MOD
Preemption ARP
CellRacThd PreemptionArpThd eNodeB CELLRACTHD
threshold
LST CELLRACTHD
MOD
Uplink RB used
CellRacThd UlRbHighThd eNodeB CELLRACTHD
ratio high threshold
LST CELLRACTHD
MOD
Downlink RB used
CellRacThd DlRbHighThd eNodeB CELLRACTHD
ratio high threshold
LST CELLRACTHD
MOD
Uplink RB used
CellRacThd UlRbLowThd eNodeB CELLRACTHD
ratio low threshold
LST CELLRACTHD
MOD
Downlink RB used
CellRacThd DlRbLowThd eNodeB CELLRACTHD
ratio low threshold
LST CELLRACTHD
MOD
MaxNonGbrBearer Non-GBR max
CellRacThd eNodeB CELLRACTHD
LST
Num bearer number
LST CELLRACTHD
CELLRFSHUTDO
WN
CellRfShutdown LocalCellId Local cell identity eNodeB MOD
MOD
CELLRFSHUTDO
CELLRFSHUTDO
RF intelligent WN
WN
CellRfShutdown RfShutdownSwitch eNodeB MOD
shutdown switch LST
CELLRFSHUTDO
CELLRFSHUTDO
WN
WN
CellRfShutdown StartTime Start time eNodeB MOD
LST
CELLRFSHUTDO
CELLRFSHUTDO
WN
WN
CellRfShutdown StopTime Stop time eNodeB MOD
LST
CELLRFSHUTDO
CELLRFSHUTDO
Reference signal WN
WN
CellRfShutdown RsPwrAdjOffset eNodeB
power adjust offset LST
LST
CELLRFSHUTDO
CELLSHUTDOWN
WN
CellShutdown LocalCellId Local cell identity eNodeB
MOD
MOD
CELLSHUTDOWN
CellShutdownSwitc Cell intelligent CELLSHUTDOWN
CellShutdown eNodeB
h shutdown switch LST
MOD
CELLSHUTDOWN
CELLSHUTDOWN
CellShutdown StartTime Start time eNodeB
LST
MOD
CELLSHUTDOWN
CELLSHUTDOWN
CellShutdown StopTime Stop time eNodeB
LST
MOD
CELLSHUTDOWN
Downlink PRB CELLSHUTDOWN
CellShutdown DlPrbThd eNodeB
threshold LST
MOD
CELLSHUTDOWN
Downlink PRB CELLSHUTDOWN
CellShutdown DlPrbOffset eNodeB
offset LST
MOD
CELLSHUTDOWN
Uplink PRB CELLSHUTDOWN
CellShutdown UlPrbThd eNodeB
threshold LST
MOD
CELLSHUTDOWN
CELLSHUTDOWN
CellShutdown UlPrbOffset Uplink PRB offset eNodeB LST
LST
CELLULICICMCPA
CELLSHUTDOWN
RA
CellULIcicMcPara LocalCellId Local cell identity eNodeB MOD
MOD
CELLULICICMCPA
CELLULICICMCPA
Uplink ICIC
RA
RA
CellULIcicMcPara ReportInterval measurement eNodeB MOD
LST
report interval CELLULICICMCPA
Uplink ICIC CELLULICICMCPA
RA
RA
CellULIcicMcPara MaxReportCellNum measurement max eNodeB
LST
report cell number
CELLULICICMCPA
RA
MOD
CELLULICICMCPA
Uplink ICIC
RA
CellULIcicMcPara ReportAmount measurement eNodeB MOD
LST
report amount CELLULICICMCPA
Uplink ICIC CELLULICICMCPA
RA
RA
CellULIcicMcPara ReportQuantity measurement eNodeB MOD
LST
report quantity CELLULICICMCPA
Uplink ICIC CELLULICICMCPA
RA
RA
CellULIcicMcPara TriggerQuantity measurement eNodeB MOD
LST
trigger quantity CELLULICICMCPA
Uplink ICIC CELLULICICMCPA
RA
RA
CellULIcicMcPara Hysteresis measurement eNodeB MOD
LST
hysteresis CELLULICICMCPA
Uplink ICIC CELLULICICMCPA
RA
RA
CellULIcicMcPara TimeToTrigger measurement time eNodeB MOD
LST
to trigger CELLULICICMCPA
CELLULICICMCPA
Uplink ICIC A3 RA
RA
CellULIcicMcPara A3Offset eNodeB
offset LST
LST
CELLULICICMCPA
CELLULSCHALGO
RA
CellUlschAlgo LocalCellId Local cell identity eNodeB
MOD
MOD
CELLULSCHALGO
Uplink Scheduling CELLULSCHALGO
CellUlschAlgo UlschStrategy eNodeB
Strategy LST
MOD
CELLULSCHALGO
adaptive HARQ CELLULSCHALGO
CellUlschAlgo AdaptHarqSwitch eNodeB
switch LST
MOD
CELLULSCHALGO
SinrAdjustTargetIble SINR target IBLER CELLULSCHALGO
CellUlschAlgo eNodeB
r adjustment LST
System Bandwidth MOD
CELLULSCHALGO
PreAllocationBand Ratio Used By Pre- CELLULSCHALGO
CellUlschAlgo eNodeB
widthRatio schedule user per LST
TTI MOD
CELLULSCHALGO
PreAllocationMinPe minimal period of CELLULSCHALGO
CellUlschAlgo eNodeB
riod pre-allocation LST
MOD
CELLULSCHALGO
data size of pre- CELLULSCHALGO
CellUlschAlgo PreAllocationSize eNodeB
allocation LST
MOD
CELLULSCHALGO
CELLULSCHALGO
CellUlschAlgo UlHoppingType Uplink hopping type eNodeB
LST
MOD
CELLULSCHALGO
FreeUserUlRbUsed Free Users Uplink CELLULSCHALGO
CellUlschAlgo eNodeB LST
Ratio RB Ratio LST
CELLALGOSWITC
CELLULSCHALGO
H
CellAlgoSwitch LocalCellId Local cell identity eNodeB MOD
MOD
CELLALGOSWITC
CELLALGOSWITC
RACH algorithm H
H
CellAlgoSwitch RachAlgoSwitch eNodeB MOD
switch LST
CELLALGOSWITC
CELLALGOSWITC
SoundingRS H
H
CellAlgoSwitch SrsAlgoSwitch eNodeB MOD
algorithm switch LST
CELLALGOSWITC
CELLALGOSWITC
PUCCH algorithm H
H
CellAlgoSwitch PucchAlgoSwitch eNodeB MOD
switch LST
CELLALGOSWITC
CELLALGOSWITC
AQM algorithm H
H
CellAlgoSwitch AqmAlgoSwitch eNodeB MOD
switch LST
CELLALGOSWITC
CELLALGOSWITC
CQI adjust H
H
CellAlgoSwitch CqiAdjAlgoSwitch eNodeB MOD
algorithm switch LST
CELLALGOSWITC
CELLALGOSWITC
RlfDetectAlgoSwitc RLF detection H
H
CellAlgoSwitch eNodeB MOD
h algorithm switch LST
CELLALGOSWITC
CELLALGOSWITC
Dynamic adjust
H
H
CellAlgoSwitch DynAdjVoltSwitch voltage algorithm eNodeB
LST
switch
CELLALGOSWITC
H
MOD
CELLALGOSWITC
RAC algorithm H
CellAlgoSwitch RacAlgoSwitch eNodeB MOD
switch LST
CELLALGOSWITC
CELLALGOSWITC
Load balancing H
H
CellAlgoSwitch MlbAlgoSwitch eNodeB MOD
algorithm switch LST
CELLALGOSWITC
CELLALGOSWITC
Downlink power
H
H
CellAlgoSwitch DlPcAlgoSwitch control algorithm eNodeB MOD
LST
switch CELLALGOSWITC
Uplink power CELLALGOSWITC
H
H
CellAlgoSwitch UlPcAlgoSwitch control algorithm eNodeB MOD
LST
switch CELLALGOSWITC
CELLALGOSWITC
H
H
CellAlgoSwitch BfAlgoSwitch BF algorithm switch eNodeB MOD
LST
CELLALGOSWITC
CELLALGOSWITC
H
H
CellAlgoSwitch DlSchSwitch DL schedule switch eNodeB MOD
LST
CELLALGOSWITC
CELLALGOSWITC
Uplink schedule H
H
CellAlgoSwitch UlSchSwitch eNodeB MOD
switch LST
CELLALGOSWITC
CELLALGOSWITC
RanShareModeSwit RAN Sharing Mode H
H
CellAlgoSwitch eNodeB MOD
ch Switch LST
CELLALGOSWITC
CELLALGOSWITC
Based on
FreqPriorityHoSwitc H
H
CellAlgoSwitch Frequency Priority eNodeB
h LST
HO Switch
CELLALGOSWITC
LST
H CELLDLICIC
CellDlIcic LocalCellId Local cell identity eNodeB
MOD CELLDLICIC
Downlink band MOD CELLDLICIC
CellDlIcic BandMode eNodeB
division scheme LST CELLDLICIC
LST
CELLDLPCPDCCH
CellDlpcPdcch LocalCellId Local cell identity eNodeB
MOD
MOD
CELLDLPCPDCCH
DCI power offset for CELLDLPCPDCCH
CellDlpcPdcch DediDciPwrOffset eNodeB
dedicated control LST
LST
CELLDLPCPDCCH
CELLDLPCPDSCH
CellDlpcPdsch LocalCellId Local cell identity eNodeB
MOD
MOD
CELLDLPCPDSCH
CELLDLPCPDSCH
CellDlpcPdsch CcuPa Center UE Pa eNodeB
LST
MOD
CELLDLPCPDSCH
CELLDLPCPDSCH
CellDlpcPdsch CeuPa Edge UE Pa eNodeB
LST
LST
CELLDLPCPDSCH
CELLDLPCPHICH
CellDlpcPhich LocalCellId Local cell identity eNodeB
MOD
MOD
CELLDLPCPHICH
Phich Pc Off Power CELLDLPCPHICH
CellDlpcPhich PwrOffset eNodeB
Offset LST
LST
CELLDLPCPHICH
CELLDLSCHALGO
CellDlschAlgo LocalCellId local Cell Identity eNodeB
MOD
MOD
CELLDLSCHALGO
Downlink CELLDLSCHALGO
CellDlschAlgo DlschStrategy eNodeB
scheduling Strategy LST
MOD
CELLDLSCHALGO
FreeUserDlRbUsed Free Users CELLDLSCHALGO
CellDlschAlgo eNodeB
Ratio Downlink RB Ratio LST
MOD
CELLDLSCHALGO
CELLDLSCHALGO
CellDlschAlgo BtServiceWeight Bt Service Weight eNodeB
LST
MOD
CELLDLSCHALGO
Other Service CELLDLSCHALGO
CellDlschAlgo OtherServiceWeight eNodeB
Weight LST
CELLDLSCHALGO
LST CELLMLB
CellMLB LocalCellId Local cell identity eNodeB
MOD CELLMLB
Intra-Frequency
Mobility Load MOD CELLMLB
CellMLB IntraFreqMlbThd eNodeB
Balancing LST CELLMLB
Inter-Frequency
Threshold
Mobility Load MOD CELLMLB
CellMLB InterFreqMlbThd eNodeB
Balancing LST CELLMLB
Threshold
Inter-RAT Mobility
MOD CELLMLB
CellMLB InterRatMlbThd Load Balancing eNodeB
LST CELLMLB
Threshold
LoadExchangePeri Load Information MOD CELLMLB
CellMLB eNodeB
od Exchange Period LST CELLMLB
MOD CELLMLB
CellMLB LoadOffset Load Offset eNodeB
LST CELLMLB
Load Difference MOD CELLMLB
CellMLB LoadDiffThd eNodeB
Threshold LST CELLMLB
LST
CELLPDCCHALGO
CellPdcchAlgo LocalCellId Local Cell Identity eNodeB
MOD
MOD
CELLPDCCHALGO
Cce Ratio Adjust CELLPDCCHALGO
CellPdcchAlgo CceRatioAdjSwitch eNodeB
Switch LST
MOD
CELLPDCCHALGO
PDCCH Initial CELLPDCCHALGO
CellPdcchAlgo InitPdcchSymNum eNodeB
Symbol Number LST
MOD
CELLPDCCHALGO
PDCCH Symbol
PdcchSymNumSwit CELLPDCCHALGO
CellPdcchAlgo Number Adjust eNodeB
ch LST
Switch LST
CELLPDCCHALGO
CELLPUCCHALGO
CellPucchAlgo LocalCellId Local cell identity eNodeB
MOD
MOD
CELLPUCCHALGO
SRI Low Load CELLPUCCHALGO
CellPucchAlgo SriLowLoadThd eNodeB LST
Threshold LST
CELLNOACCESSA
CELLPUCCHALGO
LMPARA
CellNoAccessAlmPa LocalCellId Local cell identity eNodeB MOD
MOD
CELLNOACCESSA
CELLNOACCESSA
NoAccessStartDete No access detect LMPARA
LMPARA
CellNoAccessAlmPa eNodeB MOD
ctTime start time LST
CELLNOACCESSA
CELLNOACCESSA
NoAccessStopDete No access detect LMPARA
LMPARA
CellNoAccessAlmPa eNodeB MOD
ctTime stop time LST
CELLNOACCESSA
CELLNOACCESSA
NoAccessDetectTi No access detect LMPARA
LMPARA
CellNoAccessAlmPa eNodeB
mer timer LST
CELLNOACCESSA
LST CELLULICIC
LMPARA
CellUlIcic LocalCellId Local cell identity eNodeB
MOD CELLULICIC
Uplink band division ADD
MOD CELLULICIC
CellUlIcic BandMode eNodeB CELLSIMULOAD
scheme LST CELLULICIC
DSP
CELLSIMULOAD
CellSimuLoad LocalCellId Local cell identity eNodeB
LST
ADD
CELLSIMULOAD
CELLSIMULOAD
RMV
CellSimuLoad SimLoadCfgIndex Configure Index eNodeB
LST
CELLSIMULOAD
ADD
CELLSIMULOAD
SimuLoadTransMo SimuLoad CELLSIMULOAD
CellSimuLoad eNodeB
de transmission mode LST
CELLSIMULOAD
SimuLoad allocated DSP
CellSimuLoad SimuLoadRbNum eNodeB
RB Number CELLSIMULOAD
Commercial service DSP
CellSimuLoad CommercRbNum eNodeB
RB number CELLSIMULOAD
SimuLoad allocated DSP
CellSimuLoad SimuLoadPower eNodeB
power CELLSIMULOAD
Commercial service DSP
CellSimuLoad CommercPower eNodeB
power CELLSIMULOAD
SimuLoad allocated DSP
CellSimuLoad SimuLoadUserNum eNodeB
user Number CELLSIMULOAD
Commercial service DSP
CellSimuLoad CommercUserNum eNodeB
user number CELLSIMULOAD
LST BCCHCFG
BcchCfg LocalCellId Local cell identity eNodeB
MOD BCCHCFG
Modification period MOD BCCHCFG
BcchCfg ModifyPeriodCoeff eNodeB
coefficient LST BCCHCFG
LST
CELLCHPWRCFG
CellChPwrCfg LocalCellId Local cell identity eNodeB
MOD
MOD
CELLCHPWRCFG
CELLCHPWRCFG
CellChPwrCfg PcfichPwr PCFICH power eNodeB
LST
MOD
CELLCHPWRCFG
CELLCHPWRCFG
CellChPwrCfg PbchPwr PBCH power eNodeB
LST
MOD
CELLCHPWRCFG
CELLCHPWRCFG
CellChPwrCfg SchPwr SCH power eNodeB
LST
MOD
CELLCHPWRCFG
CELLCHPWRCFG
CellChPwrCfg DbchPwr DBCH power eNodeB
LST
MOD
CELLCHPWRCFG
CELLCHPWRCFG
CellChPwrCfg PchPwr PCH power eNodeB
LST
MOD
CELLCHPWRCFG
Rach response CELLCHPWRCFG
CellChPwrCfg RaRspPwr eNodeB
power LST
MOD
CELLCHPWRCFG
CELLCHPWRCFG
CellChPwrCfg PrsPwr Prs power eNodeB
LST
CELLCHPWRCFG
LST PDSCHCFG
PDSCHCfg LocalCellId Local cell identity eNodeB
MOD PDSCHCFG
ReferenceSignalPw Reference signal MOD PDSCHCFG
PDSCHCfg eNodeB
r power LST PDSCHCFG
MOD PDSCHCFG
PDSCHCfg Pb PB eNodeB
LST PDSCHCFG
LST RACHCFG
RACHCfg LocalCellId Local cell identity eNodeB
MOD RACHCFG
MOD RACHCFG
RACHCfg PwrRampingStep Power ramping step eNodeB
LST RACHCFG
Preamble initial
PreambInitRcvTarg MOD RACHCFG
RACHCfg received target eNodeB
etPwr LST RACHCFG
power
LST SRSCFG
SRSCfg LocalCellId Local cell identity eNodeB
MOD SRSCFG
SRS subframe MOD SRSCFG
SRSCfg SrsSubframeCfg eNodeB
configuration LST SRSCFG
SRS ACK/NACK
MOD SRSCFG
SRSCfg AnSrsSimuTrans simultaneous eNodeB
LST SRSCFG
transmission
LST PHICHCFG
PHICHCfg LocalCellId Local cell identity eNodeB
MOD PHICHCFG
MOD PHICHCFG
PHICHCfg PhichDuration PHICH duration eNodeB
LST PHICHCFG
MOD PHICHCFG
PHICHCfg PhichResource PHICH resource eNodeB
LST PHICHCFG
LST PCCHCFG
PCCHCfg LocalCellId Local cell identity eNodeB
MOD PCCHCFG
Default paging MOD PCCHCFG
PCCHCfg DefaultPagingCycle eNodeB
cycle LST PCCHCFG
MOD PCCHCFG
PCCHCfg Nb NB eNodeB
LST PCCHCFG
LST PUSCHCFG
PUSCHCfg LocalCellId Local cell identity eNodeB
MOD PUSCHCFG
MOD PUSCHCFG
PUSCHCfg Nsb Subband number eNodeB
LST PUSCHCFG
MOD PUSCHCFG
PUSCHCfg HoppingMode Hopping mode eNodeB
LST PUSCHCFG
MOD PUSCHCFG
PUSCHCfg HoppingOffset Hopping offset eNodeB
LST PUSCHCFG
GroupHoppingEnab Group hopping MOD PUSCHCFG
PUSCHCfg eNodeB
led enabled LST PUSCHCFG
GroupAssignPUSC Group assignment MOD PUSCHCFG
PUSCHCfg eNodeB
H PUSCH LST PUSCHCFG
SeqHoppingEnable Sequence hopping MOD PUSCHCFG
PUSCHCfg eNodeB
d enabled LST PUSCHCFG
MOD PUSCHCFG
PUSCHCfg CyclicShift Cyclic shift eNodeB
LST PUSCHCFG
MOD PUSCHCFG
PUSCHCfg Qam64Enabled Qam64 enabled eNodeB
LST PUSCHCFG
LST PUCCHCFG
PUCCHCfg LocalCellId Local cell identity eNodeB
MOD PUCCHCFG
ADD
MOD PUCCHCFG
CDMA2000EXTER
PUCCHCfg DeltaShift Delta shift eNodeB
LST PUCCHCFG
NALCELLPLMN
ADD
LST
Cdma2000ExternalCeCellGlobalId Sector identity eNodeB CDMA2000EXTER
CDMA2000EXTER
NALCELLPLMN
NALCELLPLMN
ADD
LST
Share mobile RMV
CDMA2000EXTER
Cdma2000ExternalCeShareMcc eNodeB ADD
CDMA2000EXTER
country code CDMA2000EXTER
NALCELLPLMN
CDMA2000HRPDN
NALCELLPLMN
NALCELLPLMN
LST
Share mobile CELL
RMV
Cdma2000ExternalCeShareMnc eNodeB ADD
CDMA2000EXTER
LST
network code CDMA2000EXTER
CDMA2000HRPDN
NALCELLPLMN
CDMA2000HRPDN
NALCELLPLMN
CELL
RMV
CELL
Cdma2000HrpdNcellLocalCellId Local cell identity eNodeB LST
CDMA2000EXTER
MOD
CDMA2000HRPDN
NALCELLPLMN
CDMA2000HRPDN
CELL
CELL
Cdma2000HrpdNcellCellGlobalId Sector identity eNodeB
MOD
RMV
CDMA2000HRPDN
CDMA2000HRPDN
CELL
CELL
RMV
CDMA2000HRPDN
CELL
ADD
CDMA2000HRPDN
CELL
ADD
MOD
No handover CDMA2000HRPDN
Cdma2000HrpdNcellNoHoFlag eNodeB CDMA2000HRPDN
indicator CELL
CELL
ADD
MOD
LST
Cdma2000HrpdNcellNoRmvFlag No remove indicator eNodeB CDMA2000HRPDN
CDMA2000HRPDN
CDMA2000HRPDN
CELL
CELL
CELL
MOD
LST
Blind handover
Cdma2000HrpdNcellBlindHoPriority eNodeB CDMA2000HRPDN
CDMA2000HRPDN
priority
CELL
CELL
ADD
LST
LST
Cdma2000HrpdNcellAnrFlag ANR flag eNodeB CDMA2000HRPDN
CDMA2000HRPDN
CDMA2000HRPDN
CELL
CELL
CELL
ADD
MOD
Cdma2000HrpdNcellLocalCellName Local cell name eNodeB CDMA2000HRPDN
CDMA2000HRPDN
CELL
CELL
MOD
ADD
LST
NeighbourCellNam Neighbour cell
Cdma2000HrpdNcell eNodeB CDMA2000HRPDN
CDMA2000NFREQ
CDMA2000HRPDN
e name
CELL
LST
CELL
ADD
LST
CDMA2000NFREQ
Cdma2000Nfreq LocalCellId Local cell identity eNodeB CDMA2000NFREQ
CDMA2000HRPDN
MOD
LST
CELL
CDMA2000NFREQ
ADD
CDMA2000NFREQ
Cdma2000Nfreq BandClass Band class eNodeB RMV
CDMA2000NFREQ
MOD
CDMA2000NFREQ
LST
CDMA2000NFREQ
CDMA2000NFREQ
RMV
Cdma2000Nfreq Frequency Frequency eNodeB ADD
MOD
CDMA2000NFREQ
CDMA2000NFREQ
CDMA2000NFREQ
MOD
RMV
Cdma2000Nfreq OffsetFreq Frequency offset eNodeB ADD
CDMA2000NFREQ
CDMA2000NFREQ
CDMA2000NFREQ
LST
SearchWindowSize Search window size MOD
CDMA2000NFREQ
Cdma2000Nfreq eNodeB ADD
CfgInd configure indicator CDMA2000NFREQ
CDMA2000NFREQ
ADD
LST
MOD
EUTRANEXTERNA
CDMA2000NFREQ
Cdma2000Nfreq SearchWindowSize Search window size eNodeB
CDMA2000NFREQ
LCELLPLMN
ADD
LST
LST
Mobile country EUTRANEXTERNA
CDMA2000NFREQ
EutranExternalCellP Mcc eNodeB EUTRANEXTERNA
code LCELLPLMN
LCELLPLMN
ADD
LST
RMV
Mobile network EUTRANEXTERNA
EutranExternalCellP Mnc eNodeB EUTRANEXTERNA
EUTRANEXTERNA
code LCELLPLMN
LCELLPLMN
LCELLPLMN
ADD
LST
RMV
EutranExternalCellP eNodeBId eNodeB identity eNodeB EUTRANEXTERNA
EUTRANEXTERNA
EUTRANEXTERNA
LCELLPLMN
LCELLPLMN
LCELLPLMN
ADD
LST
RMV
EutranExternalCellP CellId Cell identity eNodeB EUTRANEXTERNA
EUTRANEXTERNA
EUTRANEXTERNA
LCELLPLMN
LCELLPLMN
LCELLPLMN
ADD
LST
RMV
Share mobile EUTRANEXTERNA
EutranExternalCellP ShareMcc eNodeB EUTRANEXTERNA
EUTRANEXTERNA
country code LCELLPLMN
LCELLPLMN
LCELLPLMN
ADD
LST
RMV
Share mobile GERANEXTERNAL
EutranExternalCellP ShareMnc eNodeB EUTRANEXTERNA
EUTRANEXTERNA
network code CELLPLMN
LCELLPLMN
LCELLPLMN
ADD
LST
RMV
GeranExternalCellP GeranCellId GERAN cell identity eNodeB GERANEXTERNAL
GERANEXTERNAL
EUTRANEXTERNA
CELLPLMN
CELLPLMN
LCELLPLMN
ADD
LST
RMV
GeranExternalCellP Lac Location area code eNodeB GERANEXTERNAL
GERANEXTERNAL
GERANEXTERNAL
CELLPLMN
CELLPLMN
CELLPLMN
ADD
LST
RMV
Mobile country GERANEXTERNAL
GeranExternalCellP Mcc eNodeB GERANEXTERNAL
GERANEXTERNAL
code CELLPLMN
CELLPLMN
CELLPLMN
ADD
LST
RMV
Mobile network GERANEXTERNAL
GeranExternalCellP Mnc eNodeB GERANEXTERNAL
GERANEXTERNAL
code CELLPLMN
CELLPLMN
CELLPLMN
LST
RMV
Share mobile
GeranExternalCellP ShareMcc eNodeB GERANEXTERNAL
GERANEXTERNAL
country code
CELLPLMN
CELLPLMN
RMV
GERANEXTERNAL
CELLPLMN
ADD
GERANEXTERNAL
CELLPLMN
ADD
LST
Share mobile UTRANEXTERNAL
GeranExternalCellP ShareMnc eNodeB GERANEXTERNAL
network code CELLPLMN
CELLPLMN
ADD
LST
RMV
UtranExternalCellPl UtranCellId UTRAN cell identity eNodeB UTRANEXTERNAL
UTRANEXTERNAL
GERANEXTERNAL
CELLPLMN
CELLPLMN
CELLPLMN
ADD
LST
RMV
Mobile country UTRANEXTERNAL
UtranExternalCellPl Mcc eNodeB UTRANEXTERNAL
UTRANEXTERNAL
code CELLPLMN
CELLPLMN
CELLPLMN
ADD
LST
RMV
Mobile network UTRANEXTERNAL
UtranExternalCellPl Mnc eNodeB UTRANEXTERNAL
UTRANEXTERNAL
code CELLPLMN
CELLPLMN
CELLPLMN
ADD
LST
RMV
Share mobile UTRANEXTERNAL
ADD
UtranExternalCellPl ShareMcc eNodeB UTRANEXTERNAL
UTRANEXTERNAL
country code CELLPLMN
CDMA2000EXTER
CELLPLMN
CELLPLMN
LST
NALCELL
RMV
Share mobile
UtranExternalCellPl ShareMnc eNodeB UTRANEXTERNAL
LST
UTRANEXTERNAL
network code
CELLPLMN
CDMA2000EXTER
CELLPLMN
ADD
RMV
NALCELL
CDMA2000EXTER
Cdma2000ExternalCeCellGlobalId Sector identity eNodeB UTRANEXTERNAL
MOD
NALCELL
CELLPLMN
ADD
CDMA2000EXTER
MOD
Cdma2000ExternalCeBandClass Band class eNodeB CDMA2000EXTER
NALCELL
CDMA2000EXTER
NALCELL
RMV
NALCELL
ADD
MOD
CDMA2000EXTER
LST
Cdma2000ExternalCeFrequency Frequency eNodeB CDMA2000EXTER
CDMA2000EXTER
NALCELL
CDMA2000EXTER
NALCELL
NALCELL
NALCELL
ADD
MOD
LST
CDMA2000EXTER
Cdma2000ExternalCePnOffset Physical cell identity eNodeB CDMA2000EXTER
CDMA2000EXTER
NALCELL
NALCELL
NALCELL
ADD
MOD
CDMA2000 LST
CDMA2000EXTER
Cdma2000ExternalCeCdma2000Type eNodeB CDMA2000EXTER
CDMA2000EXTER
neighbor cell type NALCELL
NALCELL
NALCELL
ADD
MOD
LST
Mobile country CDMA2000EXTER
Cdma2000ExternalCeMcc eNodeB CDMA2000EXTER
CDMA2000EXTER
code NALCELL
NALCELL
NALCELL
ADD
MOD
LST
Mobile network CDMA2000EXTER
ADD
Cdma2000ExternalCeMnc eNodeB CDMA2000EXTER
CDMA2000EXTER
code NALCELL
CDMA20001XRTT
NALCELL
NALCELL
MOD
NCELL
LST
Cdma2000ExternalCeCellName Cell name eNodeB ADD
CDMA2000EXTER
LST
CDMA2000EXTER
CDMA20001XRTT
NALCELL
CDMA20001XRTT
NALCELL
NCELL
LST
NCELL
Cdma20001XRTTNceLocalCellId Local cell identity eNodeB LST
CDMA2000EXTER
MOD
CDMA20001XRTT
NALCELL
ADD
CDMA20001XRTT
NCELL
CDMA20001XRTT
NCELL
Cdma20001XRTTNceCellGlobalId Sector identity eNodeB
MOD
NCELL
RMV
ADD
CDMA20001XRTT
MOD
No handover CDMA20001XRTT
Cdma20001XRTTNceNoHoFlag eNodeB CDMA20001XRTT
NCELL
CDMA20001XRTT
indicator NCELL
NCELL
RMV
NCELL
ADD
MOD
CDMA20001XRTT
LST
Cdma20001XRTTNceNoRmvFlag No remove indicator eNodeB CDMA20001XRTT
CDMA20001XRTT
NCELL
CDMA20001XRTT
NCELL
NCELL
NCELL
MOD
Blind handover LST
Cdma20001XRTTNceBlindHoPriority eNodeB CDMA20001XRTT
CDMA20001XRTT
priority
NCELL
NCELL
ADD
LST
LST
Cdma20001XRTTNceAnrFlag ANR flag eNodeB CDMA20001XRTT
CDMA20001XRTT
CDMA20001XRTT
NCELL
NCELL
NCELL
ADD
MOD
Cdma20001XRTTNceLocalCellName Local cell name eNodeB CDMA20001XRTT
ADD
CDMA20001XRTT
NCELL
CDMA2000BANDC
NCELL
MOD
LASS
LST
NeighbourCellNam Neighbour cell
Cdma20001XRTTNce eNodeB CDMA20001XRTT
LST
CDMA20001XRTT
e name
NCELL
CDMA2000BANDC
NCELL
LST
LASS
Cdma2000BandClas LocalCellId Local cell identity eNodeB CDMA20001XRTT
MOD
NCELL
CDMA2000BANDC
LASS
RMV
CDMA2000BANDC
LASS
ADD
CDMA2000BANDC
LASS
LST
CDMA2000BANDC
ADD
LASS
CDMA2000BANDC
Cdma2000BandClas BandClass Band class eNodeB
MOD
LASS
ADD
CDMA2000BANDC
MOD
Cell reselection CDMA2000BANDC
LASS
Cdma2000BandClas CellReselPriority eNodeB CDMA2000BANDC
priority LASS
RMV
LASS
ADD
MOD
CDMA2000BANDC
LST
High priority CDMA2000BANDC
ADD
Cdma2000BandClas ThreshXHigh eNodeB CDMA2000BANDC
LASS
CDMA2000BANDC
threshold LASS
GERANEXTERNAL
LASS
LASS
MOD
CELL
LST
Lower priority ADD
Cdma2000BandClas ThreshXLow eNodeB CDMA2000BANDC
LST
CDMA2000BANDC
threshold GERANEXTERNAL
LASS
GERANEXTERNAL
LASS
Mobile country CELL
LST
CELL
GeranExternalCell Mcc eNodeB ADD
LST
code CDMA2000BANDC
MOD
GERANEXTERNAL
GERANEXTERNAL
LASS
GERANEXTERNAL
Mobile network CELL
CELL
GeranExternalCell Mnc eNodeB CELL
ADD
LST
code MOD
RMV
GERANEXTERNAL
GERANEXTERNAL
GERANEXTERNAL
GERANEXTERNAL
CELL
CELL
GeranExternalCell GeranCellId GERAN cell identity eNodeB CELL
CELL
LST
MOD
RMV
GERANEXTERNAL
ADD
GERANEXTERNAL
GERANEXTERNAL
CELL
GeranExternalCell Lac Location area code eNodeB GERANEXTERNAL
CELL
CELL
MOD
CELL
RMV
ADD
GERANEXTERNAL
MOD
Routing area code GERANEXTERNAL
GeranExternalCell RacCfgInd eNodeB GERANEXTERNAL
CELL
GERANEXTERNAL
configure indicator CELL
CELL
RMV
CELL
ADD
MOD
GERANEXTERNAL
LST
GeranExternalCell Rac Routing area code eNodeB GERANEXTERNAL
GERANEXTERNAL
CELL
GERANEXTERNAL
CELL
CELL
CELL
ADD
MOD
LST
GERANEXTERNAL
GeranExternalCell BandIndicator Band indicator eNodeB GERANEXTERNAL
GERANEXTERNAL
CELL
CELL
CELL
ADD
MOD
LST
GERANEXTERNAL
GeranExternalCell GeranArfcn GERAN ARFCN eNodeB GERANEXTERNAL
GERANEXTERNAL
CELL
CELL
CELL
ADD
MOD
NetworkColourCod Network colour LST
GERANEXTERNAL
GeranExternalCell eNodeB GERANEXTERNAL
GERANEXTERNAL
e code CELL
CELL
CELL
ADD
MOD
LST
BaseStationColour Base station colour GERANEXTERNAL
GeranExternalCell eNodeB GERANEXTERNAL
GERANEXTERNAL
Code code CELL
CELL
CELL
ADD
MOD
LST
GeranExternalCell DtmInd DTM indication eNodeB GERANEXTERNAL
GERANEXTERNAL
GERANEXTERNAL
CELL
CELL
CELL
MOD
LST
GeranExternalCell CellName Cell name eNodeB ADD
GERANEXTERNAL
GERANEXTERNAL
GERANNCELL
CELL
CELL
LST
LST GERANNCELL
GeranNcell LocalCellId Local cell identity eNodeB ADD
MOD
GERANEXTERNAL
GERANNCELL
GERANNCELL
CELL
LST
RMV GERANNCELL
Mobile country ADD
GeranNcell Mcc eNodeB MOD
GERANNCELL
code GERANNCELL
GERANNCELL
LST
RMV GERANNCELL
Mobile network ADD
GeranNcell Mnc eNodeB MOD
GERANNCELL
code GERANNCELL
GERANNCELL
LST
RMV GERANNCELL
GeranNcell Lac Location area code eNodeB ADD
MOD
GERANNCELL
GERANNCELL
GERANNCELL
LST
RMVGERANNCELL
GeranNcell GeranCellId GERAN cell identity eNodeB MOD
GERANNCELL
ADD
GERANNCELL
GERANNCELL
RMV
GeranNcell NoRmvFlag No remove indicator eNodeB MOD
GERANNCELL
ADD
GERANNCELL
GERANNCELL
LST GERANNCELL
No handover
GeranNcell NoHoFlag eNodeB MOD
indicator
GERANNCELL
LST GERANNCELL
ADD
GERANNCELL
Blind handover
GeranNcell BlindHoPriority eNodeB MOD
priority
GERANNCELL
LST GERANNCELL
GeranNcell AnrFlag ANR flag eNodeB LST GERANNCELL
ADD
GERANNCELL
GeranNcell LocalCellName Local cell name eNodeB ADD
MOD
ADD
GERANNFREQGR
GERANNCELL
GERANNCELL
OUP
LST GERANNCELL
NeighbourCellNam Neighbour cell ADD
GeranNcell eNodeB MOD
LST
e name GERANNFREQGR
GERANNCELL
GERANNFREQGR
OUP
LST
OUPGERANNCELL
GeranNfreqGroup LocalCellId Local cell identity eNodeB LST
MOD
GERANNFREQGR
ADD
GERANNFREQGR
BCCH group OUP
GERANNFREQGR
OUP
GeranNfreqGroup BcchGroupId eNodeB
identity MOD
OUP
RMV
ADD
GERANNFREQGR
MOD
GERANNFREQGR
GeranNfreqGroup GeranVersion GERAN version eNodeB GERANNFREQGR
OUP
GERANNFREQGR
OUP
OUP
RMV
OUP
ADD
MOD
GERANNFREQGR
LST
GeranNfreqGroup StartingArfcn Starting ARFCN eNodeB GERANNFREQGR
GERANNFREQGR
OUP
GERANNFREQGR
OUP
OUP
OUP
ADD
MOD
LST
GERANNFREQGR
GeranNfreqGroup BandIndicator Band indicator eNodeB GERANNFREQGR
GERANNFREQGR
OUP
OUP
Cell reselection OUP
ADD
MOD
CellReselPriorityCfg LST
GERANNFREQGR
GeranNfreqGroup priority configure eNodeB GERANNFREQGR
GERANNFREQGR
Ind OUP
indicator OUP
OUP
ADD
MOD
LST
Cell reselection GERANNFREQGR
GeranNfreqGroup CellReselPriority eNodeB GERANNFREQGR
GERANNFREQGR
priority OUP
OUP
OUP
ADD
MOD
LST
PMAX configure GERANNFREQGR
GeranNfreqGroup PmaxGeranCfgInd eNodeB GERANNFREQGR
GERANNFREQGR
indicator OUP
OUP
OUP
ADD
MOD
LST
GeranNfreqGroup PmaxGeran PMAX eNodeB GERANNFREQGR
GERANNFREQGR
GERANNFREQGR
OUP
OUP
OUP
ADD
MOD
LST
Minimum required GERANNFREQGR
GeranNfreqGroup QRxLevMin eNodeB GERANNFREQGR
GERANNFREQGR
RX level OUP
OUP
OUP
ADD
MOD
LST
High priority GERANNFREQGR
GeranNfreqGroup ThreshXHigh eNodeB GERANNFREQGR
GERANNFREQGR
threshold OUP
OUP
OUP
ADD
MOD
LST
Lower priority GERANNFREQGR
GeranNfreqGroup ThreshXLow eNodeB GERANNFREQGR
GERANNFREQGR
threshold OUP
OUP
OUP
ADD
MOD
LST
GeranNfreqGroup OffsetFreq Frequency offset eNodeB GERANNFREQGR
GERANNFREQGR
GERANNFREQGR
OUP
OUP
OUP
ADD
MOD
LST
NCC monitoring GERANNFREQGR
GeranNfreqGroup NccPermitted eNodeB GERANNFREQGR
GERANNFREQGR
permitted OUPARFCN
OUP
OUP
ADD
LST
LST
GeranNfreqGroupArfLocalCellId Local cell identity eNodeB GERANNFREQGR
GERANNFREQGR
GERANNFREQGR
OUPARFCN
OUPARFCN
OUP
ADD
LST
RMV
BCCH group GERANNFREQGR
GeranNfreqGroupArfBcchGroupId eNodeB GERANNFREQGR
GERANNFREQGR
identity OUPARFCN
OUPARFCN
OUPARFCN
ADD
LST
RMV
GeranNfreqGroupArfGeranArfcn GERAN ARFCN eNodeB INTRAFREQBLKC
GERANNFREQGR
GERANNFREQGR
ELL
OUPARFCN
OUPARFCN
ADD
LST
RMV
IntraFreqBlkCell LocalCellId Local cell identity eNodeB INTRAFREQBLKC
INTRAFREQBLKC
GERANNFREQGR
ELL
ELL
OUPARFCN
LST
RMV
IntraFreqBlkCell PhyCellId Physical cell identity eNodeB INTRAFREQBLKC
INTRAFREQBLKC
ELL
ELL
RMV
INTRAFREQBLKC
ELL
ADD
EUTRANINTRAFR
EQNCELL
ADD
LST
EUTRANINTRAFR
EUTRANINTRAFR
EQNCELL
EQNCELL
EutranIntraFreqNCel LocalCellId Local cell identity eNodeB ADD
LST
MOD
EUTRANINTRAFR
EUTRANINTRAFR
EUTRANINTRAFR
Mobile country EQNCELL
EQNCELL
EutranIntraFreqNCel Mcc eNodeB EQNCELL
ADD
LST
code MOD
RMV
EUTRANINTRAFR
EUTRANINTRAFR
EUTRANINTRAFR
Mobile network EUTRANINTRAFR
EQNCELL
EQNCELL
EutranIntraFreqNCel Mnc eNodeB EQNCELL
ADD
EQNCELL
LST
code MOD
RMV
EUTRANINTRAFR
EUTRANINTRAFR
EUTRANINTRAFR
EUTRANINTRAFR
EQNCELL
EQNCELL
EutranIntraFreqNCel eNodeBId eNodeB identity eNodeB EQNCELL
EQNCELL
LST
MOD
RMV
EUTRANINTRAFR
ADD
EUTRANINTRAFR
EUTRANINTRAFR
EQNCELL
EutranIntraFreqNCel CellId Cell identity eNodeB EUTRANINTRAFR
EQNCELL
EQNCELL
MOD
EQNCELL
RMV
ADD
EUTRANINTRAFR
MOD
EUTRANINTRAFR
EutranIntraFreqNCel CellIndividualOffset Cell individual offset eNodeB EUTRANINTRAFR
EQNCELL
EUTRANINTRAFR
EQNCELL
EQNCELL
RMV
EQNCELL
ADD
MOD
EUTRANINTRAFR
LST
EutranIntraFreqNCel CellQoffset Cell offset eNodeB EUTRANINTRAFR
EUTRANINTRAFR
EQNCELL
EUTRANINTRAFR
EQNCELL
EQNCELL
EQNCELL
ADD
MOD
No handover LST
EUTRANINTRAFR
EutranIntraFreqNCel NoHoFlag eNodeB EUTRANINTRAFR
EUTRANINTRAFR
indicator EQNCELL
EQNCELL
EQNCELL
MOD
LST
EutranIntraFreqNCel NoRmvFlag No remove indicator eNodeB EUTRANINTRAFR
EUTRANINTRAFR
EQNCELL
EQNCELL
ADD
LST
LST
EutranIntraFreqNCel AnrFlag ANR flag eNodeB EUTRANINTRAFR
EUTRANINTRAFR
EUTRANINTRAFR
EQNCELL
EQNCELL
EQNCELL
ADD
MOD
EutranIntraFreqNCel LocalCellName Local cell name eNodeB EUTRANINTRAFR
ADD
EUTRANINTRAFR
EQNCELL
EUTRANINTERNF
EQNCELL
MOD
REQ
LST
NeighbourCellNam Neighbour cell ADD
EutranIntraFreqNCel eNodeB EUTRANINTRAFR
LST
EUTRANINTRAFR
e name EUTRANINTERNF
EQNCELL
EUTRANINTERNF
EQNCELL
REQ
LST
REQ
EutranInterNFreq LocalCellId Local cell identity eNodeB LST
EUTRANINTRAFR
MOD
EUTRANINTERNF
EQNCELL
ADD
EUTRANINTERNF
REQ
EUTRANINTERNF
REQ
EutranInterNFreq DlEarfcn Downlink EARFCN eNodeB
MOD
REQ
RMV
ADD
EUTRANINTERNF
MOD
Uplink EARFCN EUTRANINTERNF
EutranInterNFreq UlEarfcnCfgInd eNodeB EUTRANINTERNF
REQ
EUTRANINTERNF
configure indicator REQ
REQ
RMV
REQ
ADD
MOD
EUTRANINTERNF
LST
EutranInterNFreq UlEarfcn Uplink EARFCN eNodeB EUTRANINTERNF
EUTRANINTERNF
REQ
EUTRANINTERNF
REQ
REQ
Inter frequency cell REQ
ADD
MOD
CellReselPriorityCfg LST
EUTRANINTERNF
EutranInterNFreq resel priority eNodeB EUTRANINTERNF
EUTRANINTERNF
Ind REQ
configure indicator REQ
REQ
ADD
MOD
LST
Inter frequency cell EUTRANINTERNF
EutranInterNFreq CellReselPriority eNodeB EUTRANINTERNF
EUTRANINTERNF
resel priority REQ
REQ
REQ
ADD
MOD
LST
EUTRAN EUTRANINTERNF
EutranInterNFreq EutranReselTime eNodeB EUTRANINTERNF
EUTRANINTERNF
reselection time REQ
Speed dependent REQ
REQ
ADD
MOD
LST
SpeedDependSPCf resel parameter EUTRANINTERNF
EutranInterNFreq eNodeB EUTRANINTERNF
EUTRANINTERNF
gInd configuring REQ
Scaling REQ
indicatorfactor of REQ
ADD
MOD
TReselEutranSfMe treseleutra in LST
EUTRANINTERNF
EutranInterNFreq eNodeB EUTRANINTERNF
EUTRANINTERNF
dium medium mobility REQ
REQ
REQ
ADD
state
Scaling factor of MOD
TReselEutranSfHig LST
EUTRANINTERNF
EutranInterNFreq treseleutra in high eNodeB EUTRANINTERNF
EUTRANINTERNF
h REQ
mobility state REQ
REQ
MOD
LST
Measurement
EutranInterNFreq MeasBandWidth eNodeB EUTRANINTERNF
EUTRANINTERNF
bandwidth
REQ
REQ
LST
EUTRANINTERNF
REQ
ADD
EUTRANINTERNF
REQ
ADD
MOD
EutranInterNFreq QoffsetFreq Frequency offset eNodeB EUTRANINTERNF
EUTRANINTERNF
REQ
REQ
ADD
MOD
Inter frequency high LST
EUTRANINTERNF
EutranInterNFreq ThreshXhigh eNodeB EUTRANINTERNF
EUTRANINTERNF
priority threshold REQ
REQ
REQ
ADD
Inter frequency MOD
LST
EutranInterNFreq ThreshXlow lower priority eNodeB EUTRANINTERNF
EUTRANINTERNF
EUTRANINTERNF
REQ
threshold REQ
REQ
ADD
MOD
LST
Minimum required EUTRANINTERNF
EutranInterNFreq QRxLevMin eNodeB EUTRANINTERNF
EUTRANINTERNF
RX level REQ
REQ
REQ
ADD
MOD
LST
PMAX configure EUTRANINTERNF
EutranInterNFreq PmaxCfgInd eNodeB EUTRANINTERNF
EUTRANINTERNF
indicator REQ
REQ
REQ
ADD
MOD
LST
EutranInterNFreq Pmax PMAX eNodeB EUTRANINTERNF
EUTRANINTERNF
EUTRANINTERNF
REQ
REQ
REQ
ADD
MOD
LST
EutranInterNFreq NeighCellConfig Neighbor cell config eNodeB EUTRANINTERNF
EUTRANINTERNF
EUTRANINTERNF
REQ
REQ
REQ
ADD
MOD
LST
PresenceAntennaP Presence antenna EUTRANINTERNF
EutranInterNFreq eNodeB EUTRANINTERNF
EUTRANINTERNF
ort1 port1 REQ
REQ
REQ
ADD
MOD
LST
InterFreqHoEventTy Inter-Freq HO INTERFREQBLKC
EutranInterNFreq eNodeB EUTRANINTERNF
EUTRANINTERNF
pe trigger Event Type ELL
REQ
REQ
ADD
LST
LST
InterFreqBlkCell LocalCellId Local cell identity eNodeB INTERFREQBLKC
INTERFREQBLKC
EUTRANINTERNF
ELL
ELL
REQ
ADD
LST
RMV
InterFreqBlkCell DlEarfcn Downlink EARFCN eNodeB INTERFREQBLKC
ADD
INTERFREQBLKC
INTERFREQBLKC
ELL
EUTRANINTERFR
ELL
ELL
LST
EQNCELL
RMV
InterFreqBlkCell PhyCellId Physical cell identity eNodeB ADD
INTERFREQBLKC
LST
INTERFREQBLKC
EUTRANINTERFR
ELL
EUTRANINTERFR
ELL
EQNCELL
RMV
EQNCELL
EutranInterFreqNCel LocalCellId Local cell identity eNodeB ADD
LST
INTERFREQBLKC
MOD
EUTRANINTERFR
EUTRANINTERFR
ELL
EUTRANINTERFR
Mobile country EQNCELL
EQNCELL
EutranInterFreqNCel Mcc eNodeB EQNCELL
ADD
LST
code MOD
RMV
EUTRANINTERFR
EUTRANINTERFR
EUTRANINTERFR
Mobile network EUTRANINTERFR
EQNCELL
EQNCELL
EutranInterFreqNCel Mnc eNodeB EQNCELL
ADD
EQNCELL
LST
code MOD
RMV
EUTRANINTERFR
EUTRANINTERFR
EUTRANINTERFR
EUTRANINTERFR
EQNCELL
EQNCELL
EutranInterFreqNCel eNodeBId eNodeB identity eNodeB EQNCELL
EQNCELL
LST
MOD
RMV
EUTRANINTERFR
ADD
EUTRANINTERFR
EUTRANINTERFR
EQNCELL
EutranInterFreqNCel CellId Cell identity eNodeB EUTRANINTERFR
EQNCELL
EQNCELL
MOD
EQNCELL
RMV
ADD
EUTRANINTERFR
MOD
EUTRANINTERFR
EutranInterFreqNCel CellIndividualOffset Cell individual offset eNodeB EUTRANINTERFR
EQNCELL
EUTRANINTERFR
EQNCELL
EQNCELL
RMV
EQNCELL
ADD
MOD
EUTRANINTERFR
LST
EutranInterFreqNCel CellQoffset Cell offset eNodeB EUTRANINTERFR
EUTRANINTERFR
EQNCELL
EUTRANINTERFR
EQNCELL
EQNCELL
EQNCELL
ADD
MOD
No handover LST
EUTRANINTERFR
EutranInterFreqNCel NoHoFlag eNodeB EUTRANINTERFR
EUTRANINTERFR
indicator EQNCELL
EQNCELL
EQNCELL
ADD
MOD
LST
EutranInterFreqNCel NoRmvFlag No remove indicator eNodeB EUTRANINTERFR
EUTRANINTERFR
EUTRANINTERFR
EQNCELL
EQNCELL
EQNCELL
MOD
LST
Blind handover
EutranInterFreqNCel BlindHoPriority eNodeB EUTRANINTERFR
EUTRANINTERFR
Priority
EQNCELL
EQNCELL
LST
LST
EutranInterFreqNCel AnrFlag ANR flag eNodeB EUTRANINTERFR
EUTRANINTERFR
EQNCELL
EQNCELL
ADD
EUTRANINTERFR
EQNCELL
ADD
MOD
EutranInterFreqNCel LocalCellName Local cell name eNodeB EUTRANINTERFR
ADD
EUTRANINTERFR
EQNCELL
EUTRANEXTERNA
EQNCELL
MOD
LCELL
LST
NeighbourCellNam Neighbour cell ADD
EutranInterFreqNCel eNodeB EUTRANINTERFR
LST
EUTRANINTERFR
e name EUTRANEXTERNA
EQNCELL
EUTRANEXTERNA
EQNCELL
Mobile country LCELL
LST
LCELL
EutranExternalCell Mcc eNodeB ADD
LST
code EUTRANINTERFR
MOD
EUTRANEXTERNA
EUTRANEXTERNA
EQNCELL
EUTRANEXTERNA
Mobile network LCELL
LCELL
EutranExternalCell Mnc eNodeB LCELL
ADD
LST
code MOD
RMV
EUTRANEXTERNA
EUTRANEXTERNA
EUTRANEXTERNA
EUTRANEXTERNA
LCELL
LCELL
EutranExternalCell eNodeBId eNodeB identity eNodeB LCELL
LCELL
LST
MOD
RMV
EUTRANEXTERNA
ADD
EUTRANEXTERNA
EUTRANEXTERNA
LCELL
EutranExternalCell CellId Cell identity eNodeB EUTRANEXTERNA
LCELL
LCELL
MOD
LCELL
RMV
ADD
EUTRANEXTERNA
MOD
EUTRANEXTERNA
EutranExternalCell DlEarfcn Downlink EARFCN eNodeB EUTRANEXTERNA
LCELL
EUTRANEXTERNA
LCELL
LCELL
RMV
LCELL
ADD
MOD
Uplink EARFCN EUTRANEXTERNA
LST
EutranExternalCell UlEarfcnCfgInd eNodeB EUTRANEXTERNA
EUTRANEXTERNA
indicator LCELL
EUTRANEXTERNA
LCELL
LCELL
LCELL
ADD
MOD
LST
EUTRANEXTERNA
EutranExternalCell UlEarfcn Uplink EARFCN eNodeB EUTRANEXTERNA
EUTRANEXTERNA
LCELL
LCELL
LCELL
ADD
MOD
LST
EUTRANEXTERNA
EutranExternalCell PhyCellId Physical cell identity eNodeB EUTRANEXTERNA
EUTRANEXTERNA
LCELL
LCELL
LCELL
ADD
MOD
LST
EUTRANEXTERNA
EutranExternalCell Tac Tracking area code eNodeB EUTRANEXTERNA
EUTRANEXTERNA
LCELL
LCELL
LCELL
MOD
LST
ADD
EutranExternalCell CellName Cell name eNodeB EUTRANEXTERNA
EUTRANEXTERNA
UTRANNCELL
LCELL
LCELL
LST UTRANNCELL
LST
ADD
UtranNCell LocalCellId Local cell identity eNodeB MOD
EUTRANEXTERNA
UTRANNCELL
UTRANNCELL
LCELL
LST UTRANNCELL
Mobile country RMV
ADD
UtranNCell Mcc eNodeB MOD
UTRANNCELL
code UTRANNCELL
UTRANNCELL
LST
RMV UTRANNCELL
Mobile network ADD
UtranNCell Mnc eNodeB MOD
UTRANNCELL
code UTRANNCELL
UTRANNCELL
LST
RMVUTRANNCELL
UtranNCell UtranCellId UTRAN cell identity eNodeB MOD
UTRANNCELL
ADD
UTRANNCELL
UTRANNCELL
RMV
No handover
UtranNCell NoHoFlag eNodeB MOD
UTRANNCELL
indicator ADD
UTRANNCELL
UTRANNCELL
LST UTRANNCELL
UtranNCell NoRmvFlag No remove indicator eNodeB MOD
ADD
UTRANNCELL
UTRANNCELL
LST UTRANNCELL
Blind handover
UtranNCell BlindHoPriority eNodeB MOD
priority
UTRANNCELL
LST UTRANNCELL
UtranNCell AnrFlag ANR flag eNodeB LST UTRANNCELL
ADD
UTRANNCELL
UtranNCell LocalCellName Local cell name eNodeB MOD
ADD
UTRANNCELL
UTRANNCELL
ADD
LST UTRANNCELL
NeighbourCellNam Neighbour cell
UtranNCell eNodeB MOD
UTRANNFREQ
e name
UTRANNCELL
LST
LST UTRANNCELL
UTRANNFREQ
UtranNFreq LocalCellId Local cell identity eNodeB
MOD
UTRANNFREQ
RMV
UTRANNFREQ
ADD
UTRANNFREQ
LST
UTRANNFREQ
UtranNFreq UtranDlArfcn Downlink UARFCN eNodeB ADD
MOD
UTRANNFREQ
UTRANNFREQ
MOD
RMV
UtranNFreq UtranVersion UTRAN version eNodeB ADD
UTRANNFREQ
UTRANNFREQ
UTRANNFREQ
LST
UTRAN cell type MOD
UTRANNFREQ
UtranNFreq UtranFddTddType eNodeB ADD
indicator UTRANNFREQ
UTRANNFREQ
LST
Uplink UARFCN MOD
UTRANNFREQ
UtranNFreq UtranUlArfcnCfgInd eNodeB ADD
indicator UTRANNFREQ
UTRANNFREQ
LST
MOD
UTRANNFREQ
UtranNFreq UtranUlArfcn Uplink UARFCN eNodeB ADD
UTRANNFREQ
UTRANNFREQ
LST
CellReselPriorityCfg Reselection priority MOD
UTRANNFREQ
UtranNFreq eNodeB ADD
Ind configure indicator UTRANNFREQ
UTRANNFREQ
LST
Cell reselection MOD
UTRANNFREQ
UtranNFreq CellReselPriority eNodeB ADD
priority UTRANNFREQ
UTRANNFREQ
LST
MOD
UTRANNFREQ
UtranNFreq PmaxUtran PMAX eNodeB ADD
UTRANNFREQ
UTRANNFREQ
LST
MOD
UTRANNFREQ
UtranNFreq OffsetFreq Frequency offset eNodeB ADD
UTRANNFREQ
UTRANNFREQ
LST
Minimum required MOD
UTRANNFREQ
UtranNFreq Qqualmin eNodeB ADD
quality level UTRANNFREQ
UTRANNFREQ
LST
Minimum required MOD
UTRANNFREQ
UtranNFreq QRxLevMin eNodeB ADD
RX level UTRANNFREQ
UTRANNFREQ
LST
UTRAN high priority MOD
UTRANNFREQ
ADD
UtranNFreq ThreshXHigh eNodeB ADD
threshold UTRANNFREQ
UTRANEXTERNAL
UTRANNFREQ
LST
UTRAN lower CELL
MOD
UtranNFreq ThreshXLow eNodeB UTRANNFREQ
ADD
LST
priority threshold UTRANNFREQ
UTRANEXTERNAL
UTRANEXTERNAL
LST
Mobile country CELL
CELL
UtranExternalCell Mcc eNodeB UTRANNFREQ
ADD
LST
code MOD
UTRANEXTERNAL
UTRANEXTERNAL
UTRANEXTERNAL
Mobile network CELL
CELL
UtranExternalCell Mnc eNodeB CELL
LST
code MOD
RMV
UTRANEXTERNAL
ADD
UTRANEXTERNAL
UTRANEXTERNAL
CELL
UtranExternalCell UtranCellId UTRAN cell identity eNodeB UTRANEXTERNAL
CELL
CELL
MOD
CELL
RMV
ADD
UTRANEXTERNAL
MOD
UTRAN cell type UTRANEXTERNAL
UtranExternalCell UtranFddTddType eNodeB UTRANEXTERNAL
CELL
UTRANEXTERNAL
indicator CELL
CELL
RMV
CELL
ADD
MOD
UTRANEXTERNAL
LST
UtranExternalCell UtranDlArfcn Downlink UARFCN eNodeB UTRANEXTERNAL
UTRANEXTERNAL
CELL
UTRANEXTERNAL
CELL
CELL
CELL
ADD
MOD
Uplink UARFCN LST
UTRANEXTERNAL
UtranExternalCell UtranUlArfcnCfgInd eNodeB UTRANEXTERNAL
UTRANEXTERNAL
configure indicator CELL
CELL
CELL
ADD
MOD
LST
UtranExternalCell UtranUlArfcn Uplink UARFCN eNodeB UTRANEXTERNAL
UTRANEXTERNAL
UTRANEXTERNAL
CELL
CELL
CELL
ADD
MOD
LST
UtranExternalCell RncId RNC identity eNodeB UTRANEXTERNAL
UTRANEXTERNAL
UTRANEXTERNAL
CELL
CELL
CELL
ADD
MOD
LST
Routing area code UTRANEXTERNAL
UtranExternalCell RacCfgInd eNodeB UTRANEXTERNAL
UTRANEXTERNAL
configure indicator CELL
CELL
CELL
MOD
LST
UtranExternalCell Rac Routing area code eNodeB UTRANEXTERNAL
UTRANEXTERNAL
CELL
CELL
LST
UTRANEXTERNAL
CELL
ADD
UTRANEXTERNAL
CELL
ADD
MOD
Primary scrambling UTRANEXTERNAL
UtranExternalCell PScrambCode eNodeB UTRANEXTERNAL
code CELL
CELL
ADD
MOD
LST
UtranExternalCell Lac Location area code eNodeB UTRANEXTERNAL
UTRANEXTERNAL
UTRANEXTERNAL
CELL
CELL
CELL
MOD
LST
UtranExternalCell CellName Cell name eNodeB UTRANEXTERNAL
UTRANEXTERNAL
CELL
CELL
ANR add cell LST ANR
MOD
ANR AddCellThd eNodeB UTRANEXTERNAL
threshold LST ANR
CELL
ANR delete cell MOD ANR
ANR DelCellThd eNodeB
threshold LST ANR
Least Handover MOD ANR
ANR NcellHoStatNum eNodeB
Num for Statistic LST ANR
MOD ANR
ANR StatisticPeriod Statistic cycle eNodeB
LST ANR
Fast ANR PCI MOD ANR
ANR FastAnrRprtAmount eNodeB
report amount LST ANR
Fast ANR PCI MOD ANR
ANR FastAnrRprtInterval eNodeB
report interval LST ANR
FastAnrCheckPerio Fast ANR checking MOD ANR
ANR eNodeB
d period LST ANR
MOD ANR
ANR FastAnrRsrpThd FastAnrRsrpThd eNodeB
LST ANR
IntraRat Fast ANR
FastAnrIntraRatMe MOD ANR
ANR measurement UE eNodeB
asUeNum LST ANR
number
IR Fast ANR
FastAnrInterRatMe MOD ANR
ANR measurement UE eNodeB
asUeNum LST ANR
number
IntraRat Fast ANR
FastAnrIntraRatUe MOD ANR
ANR valid measurement eNodeB
NumThd LST ANR
min UE number
InterRat Fast ANR
FastAnrInterRatUe MOD ANR
ANR valid measurement eNodeB MOD
NumThd LST ANR
min UE number ENODEBALGOSWI
Handover Algo TCH
ENodeBAlgoSwitch HoAlgoSwitch eNodeB MOD
switch LST
ENODEBALGOSWI
ENODEBALGOSWI
Handover Mode TCH
TCH
ENodeBAlgoSwitch HoModeSwitch eNodeB MOD
switch LST
ENODEBALGOSWI
ENODEBALGOSWI
DlIcic algorithm TCH
TCH
ENodeBAlgoSwitch DlIcicSwitch eNodeB MOD
switch LST
ENODEBALGOSWI
ENODEBALGOSWI
ANR algorithm TCH
TCH
ENodeBAlgoSwitch AnrSwitch eNodeB MOD
switch LST
ENODEBALGOSWI
ENODEBALGOSWI
TCH
TCH
ENodeBAlgoSwitch RedirectSwitch Redirection switch eNodeB MOD
LST
ENODEBALGOSWI
ENODEBALGOSWI
MRO algorithm TCH
TCH
ENodeBAlgoSwitch MroSwitch eNodeB MOD
switch LST
ENODEBALGOSWI
ENODEBALGOSWI
TCH
TCH
ENodeBAlgoSwitch TpeSwitch TPE switch eNodeB MOD
LST
ENODEBALGOSWI
ENODEBALGOSWI
TCH
TCH
ENodeBAlgoSwitch UlIcicTimeSwitch UlIcic time switch eNodeB
LST
ENODEBALGOSWI
TCH
MOD
ENODEBALGOSWI
TCH
ENodeBAlgoSwitch UlIcicFreqSwitch UlIcic freq switch eNodeB MOD
LST
ENODEBALGOSWI
ENODEBALGOSWI
TCH
TCH
ENodeBAlgoSwitch LcsSwitch LCS switch eNodeB MOD
LST
ENODEBALGOSWI
ENODEBALGOSWI
TCH
TCH
ENodeBAlgoSwitch TrmSwitch TRM switch eNodeB MOD
LST
ENODEBALGOSWI
ENODEBALGOSWI
PciConflictAlmSwitc PCI conflict alarm TCH
TCH
ENodeBAlgoSwitch eNodeB
h switch LST
ENODEBALGOSWI
MRO optimization MOD
TCH MRO
MRO OptPeriod eNodeB
period LST MRO
Ncell optimization MOD MRO
MRO NcellOptThd eNodeB
threshold LST MRO
MRO statistics MOD MRO
MRO StatNumThd eNodeB
number threshold LST MRO
Pingpong handover MOD MRO
MRO PingpongTimeThd eNodeB
threshold LST MRO
Pingpong ratio MOD MRO
MRO PingpongRatioThd eNodeB
threshold LST MRO
LST SIMULOAD
SimuLoad SimuLoadCfgIndex configuration index eNodeB
MOD SIMULOAD
MOD SIMULOAD
SimuLoad SimuLoadRbThd RB usage threshold eNodeB
LST SIMULOAD
Power usage MOD SIMULOAD
SimuLoad SimuLoadPwrThd eNodeB
threshold LST SIMULOAD
SimuLoadReportPe MOD SIMULOAD
SimuLoad Report period eNodeB
riod LST SIMULOAD
SimuLoadStatPerio MOD SIMULOAD
SimuLoad Statistic period eNodeB
d LST SIMULOAD
Frequency selective MOD SIMULOAD
SimuLoad FreqSelSwitch eNodeB MOD
switch LST SIMULOAD
TDDFRAMEOFFSE
T
TddFrameOffset TimeOffset TDD time offset eNodeB
LST
TDDFRAMEOFFSE
MOD
T TPEALGO
TpeAlgo PortListNum TPE Port Number eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port1 TPE Port 1 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port2 TPE Port 2 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port3 TPE Port 3 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port4 TPE Port 4 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port5 TPE Port 5 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port6 TPE Port 6 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port7 TPE Port 7 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port8 TPE Port 8 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port9 TPE Port 9 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port10 TPE Port 10 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port11 TPE Port 11 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port12 TPE Port 12 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port13 TPE Port 13 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port14 TPE Port 14 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port15 TPE Port 15 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port16 TPE Port 16 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port17 TPE Port 17 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port18 TPE Port 18 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port19 TPE Port 19 eNodeB
LST TPEALGO
MOD TPEALGO
TpeAlgo Port20 TPE Port 20 eNodeB
LST
ADDTPEALGO
CA
LST CA
Certificate Authority
CA CANAME eNodeB MOD CA
Name
REQ DEVCERT
ADD
RMV CA
ADD CA
Certificate Authority
CA URL eNodeB MOD CA
NODETORSCGRP
URL
LST CA
OBJTORSCGROU NODETORSCGRP
NODETORSCGRP Mapping ID eNodeB ADD
PID MOD
NODETORSCGRP
NODETORSCGRP
MOD
RMV
NODETORSCGRP S1X2FLAG S1/X2 Identifier eNodeB ADD
NODETORSCGRP
NODETORSCGRP
NODETORSCGRP
LST
MOD
NODETORSCGRP
NODETORSCGRP ISALLMATCH IsAllMatch eNodeB ADD
NODETORSCGRP
NODETORSCGRP
LST
MOD
NODETORSCGRP
NODETORSCGRP ENDPOINTID Node Identifier eNodeB ADD
NODETORSCGRP
NODETORSCGRP
LST
MOD
NODETORSCGRP
NODETORSCGRP CABINETNO CabinetNo eNodeB ADD
NODETORSCGRP
NODETORSCGRP
LST
MOD
NODETORSCGRP
NODETORSCGRP SUBRACKNO SubrackNo eNodeB ADD
NODETORSCGRP
NODETORSCGRP
LST
MOD
NODETORSCGRP
NODETORSCGRP SLOTNO SlotNo eNodeB
NODETORSCGRP
LST
NODETORSCGRP
ADD
NODETORSCGRP
ResourceGroupTyp MOD
NODETORSCGRP RSCGRPT eNodeB ADD
e NODETORSCGRP
NODETORSCGRP
LST
Resource Group MOD
NODETORSCGRP
NODETORSCGRP RSCGRPN eNodeB ADD
No. NODETORSCGRP
NODETORSCGRP
LST
MOD
NODETORSCGRP
NODETORSCGRP SBT Subboard Type eNodeB ADD
NODETORSCGRP
NODETORSCGRP
LST
MOD
NODETORSCGRP
NODETORSCGRP PN Bearing Port No. eNodeB ADD
NODETORSCGRP
NODETORSCGRP
LST
MOD
NODETORSCGRP
NODETORSCGRP PT Bearing Port Type eNodeB
NODETORSCGRP
ACT
LST DOT1X
DEA DOT1X
NODETORSCGRP
DOT1X PN Port No. eNodeB
DSP DOT1X
LST DOT1X
DSP DOT1X
DOT1X ACT Active Sign eNodeB
LST DOT1X
ACT DOT1X
DOT1X AM Authentic Method eNodeB DSP DOT1X
LST DOT1X
Abnormal Packet
DOT1X APN eNodeB DSP DOT1X
Number

DOT1X AFN Fail Number eNodeB DSP DOT1X

DOT1X AFR Fail Reason eNodeB DSP DOT1X

Receive EAP
DOT1X RPN eNodeB DSP DOT1X
Packet Number

DOT1X AR Authentic State eNodeB DSP DOT1X

Send EAP Packet


DOT1X SPN eNodeB DSP DOT1X
Number
Authentic Succeed
DOT1X ASN eNodeB DSP
MODDOT1X
Number
LICFLOWCTRLAL
Uplink Traffic G
LicRatio UPRATIO eNodeB MOD
License Ratio LST
LICFLOWCTRLAL
LICFLOWCTRLAL
TRAFFICSHARETY G
G
LicRatio Traffic Sharing Type eNodeB MOD
PE LST
LICFLOWCTRLAL
LICFLOWCTRLAL
OP1TRAFFICRATI Operator 1 Traffic G
G
LicRatio eNodeB MOD
O Ratio LST
LICFLOWCTRLAL
LICFLOWCTRLAL
OP2TRAFFICRATI Operator 2 Traffic G
G
LicRatio eNodeB MOD
O Ratio LST
LICFLOWCTRLAL
LICFLOWCTRLAL
OP3TRAFFICRATI Operator 3 Traffic G
G
LicRatio eNodeB MOD
O Ratio LST
LICFLOWCTRLAL
LICFLOWCTRLAL
OP4TRAFFICRATI Operator 4 Traffic G
G
LicRatio eNodeB MOD
O Ratio LST
LICFLOWCTRLAL
LICFLOWCTRLAL
OP1TRAFFICSHA Operator 1 Traffic G
G
LicRatio eNodeB MOD
RRATIO Sharing Ratio LST
LICFLOWCTRLAL
LICFLOWCTRLAL
OP2TRAFFICSHA Operator 2 Traffic G
G
LicRatio eNodeB
RRATIO Sharing Ratio LST
LICFLOWCTRLAL
G
MOD
LICFLOWCTRLAL
OP3TRAFFICSHA Operator 3 Traffic G
LicRatio eNodeB MOD
RRATIO Sharing Ratio LST
LICFLOWCTRLAL
LICFLOWCTRLAL
OP4TRAFFICSHA Operator 4 Traffic G
G
LicRatio eNodeB
RRATIO Sharing Ratio LST
ADD MME
LICFLOWCTRLAL
DSP MME
MME MMEID MME ID eNodeB G MME
LST
MOD MME
ADD
RMV MME
MME
MME FIRSTSIGIP First Signalling IP eNodeB MOD MME
LST MME
ADD MME
MME FIRSTIPSECFLAG First IPSec Flag eNodeB MOD MME
LST MME
ADD MME
MME FIRSTIKEPEERNM First IKEPeer Name eNodeB MOD MME
LST MME
ADD MME
FIRSTIPSECPROP First IPSecProp
MME eNodeB MOD MME
NM Name
LST MME
ADD MME
Second Signalling
MME SECSIGIP eNodeB MOD MME
IP
LST MME
ADD MME
MME SECIPSECFLAG Second IPSec Flag eNodeB MOD MME
LST MME
ADD MME
Second IKEPeer
MME SECIKEPEERNM eNodeB MOD MME
Name
LST MME
ADD MME
SECIPSECPROPN Second IPSecProp
MME eNodeB MOD MME
M Name
LST MME
ADD MME
MME LOCPORT Local Port No. eNodeB MOD MME
LST MME
ADD MME
MME DESCRIPTION Description of MME eNodeB MOD MME
LST MME
ADD MME
MME CNOPERATORID CnOperatorId eNodeB MOD MME
LST MME
ADD S1SERVIP
S1ServIP CN Cabinet No. eNodeB MOD S1SERVIP
LST S1SERVIP
ADD S1SERVIP
S1ServIP SRN Subrack No. eNodeB MOD S1SERVIP
LST S1SERVIP
ADD S1SERVIP
S1ServIP SN Slot No. eNodeB MOD S1SERVIP
LST S1SERVIP
ADD S1SERVIP
LST S1SERVIP
S1ServIP S1SERVIP S1 Service IP eNodeB
MOD S1SERVIP
RMV S1SERVIP
ADD S1SERVIP
S1ServIP IPSECFLAG IPSec Flag eNodeB MOD S1SERVIP
LST S1SERVIP
ADD S1SERVIP
S1ServIP IKEIP Local IKE IP eNodeB MOD S1SERVIP
LST S1SERVIP
ADD S1SIGIP
S1SigIP CN Cabinet No. eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP SRN Subrack No. eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP SN Slot No. eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
LST S1SIGIP
S1SigIP LOCIP Local IP eNodeB
MOD S1SIGIP
RMV S1SIGIP
ADD S1SIGIP
S1SigIP LOCIPSECFLAG Local IPSec Flag eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP LOCIKEIP Local IKE IP eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP SECLOCIP Second Local IP eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
SECLOCIPSECFLA Second Local
S1SigIP eNodeB MOD S1SIGIP
G IPSec Flag
LST S1SIGIP
ADD S1SIGIP
Second Local IKE
S1SigIP SECLOCIKEIP eNodeB MOD S1SIGIP
IP
LST S1SIGIP
ADD S1SIGIP
S1SigIP LOCPORT Local Port No. eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP RTOMIN RTO Min Value eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP RTOMAX RTO Max Value eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP RTOINIT RTO Initial Value eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP RTOALPHA RTO Alpha Value eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP RTOBETA RTO Beta Value eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
S1SigIP HBINTER Heart-beat Interval eNodeB MOD S1SIGIP
LST S1SIGIP
ADD S1SIGIP
Max Association
S1SigIP MAXASSOCRETR eNodeB MOD S1SIGIP
Retransmission
LST S1SIGIP
ADD S1SIGIP
Max Path
S1SigIP MAXPATHRETR eNodeB MOD S1SIGIP
Retransmission
LST S1SIGIP
ADD S1SIGIP
Transmit Message
S1SigIP CHKSUMTX eNodeB MOD S1SIGIP
Checksum Flag
LST S1SIGIP
ADD S1SIGIP
Receive Message
S1SigIP CHKSUMRX eNodeB MOD S1SIGIP
Checksum Flag
LST S1SIGIP
ADD S1SIGIP
Checksum
S1SigIP CHKSUMTYPE eNodeB MOD S1SIGIP
Arithmetic Type
LST S1SIGIP
ADD S1SIGIP
SWITCHBACKFLA
S1SigIP Switch Back Flag eNodeB MOD S1SIGIP
G
LST S1SIGIP
ADD S1SIGIP
SWITCHBACKHBN Heart-beat Times
S1SigIP eNodeB MOD S1SIGIP
UM When Switch Back ADD SGW
LST S1SIGIP
DSP SGW
SGW SGWID Service Gateway ID eNodeB LST SGW
MOD SGW
ADD
RMV SGW
SGW
SGW SERVIP1 First Service IP eNodeB MOD SGW
LST SGW
ADD SGW
SERVIP1IPSECFL First Service IP
SGW eNodeB MOD SGW
AG IPSec Flag
LST SGW
ADD SGW
SERVIP1IKEPPER First Service IP
SGW eNodeB MOD SGW
NM IKEPeer Name
LST SGW
ADD SGW
SERVIP1IPSECPR First Service IP
SGW eNodeB MOD SGW
OPNM IPSecProp Name
LST SGW
ADD SGW
SGW SERVIP2 Second Service IP eNodeB MOD SGW
LST SGW
ADD SGW
SERVIP2IPSECFL Second Service IP
SGW eNodeB MOD SGW
AG IPSec Flag
LST SGW
ADD SGW
SERVIP2IKEPPER Second Service IP
SGW eNodeB MOD SGW
NM IKEPeer Name
LST SGW
ADD SGW
SERVIP2IPSECPR Second Service IP
SGW eNodeB MOD SGW
OPNM IPSecProp Name
LST SGW
ADD SGW
SGW SERVIP3 Third Service IP eNodeB MOD SGW
LST SGW
ADD SGW
SERVIP3IPSECFL Third Service IP
SGW eNodeB MOD SGW
AG IPSec Flag
LST SGW
ADD SGW
SERVIP3IKEPPER Third Service IP
SGW eNodeB MOD SGW
NM IKEPeer Name
LST SGW
ADD SGW
SERVIP3IPSECPR Third Service IP
SGW eNodeB MOD SGW
OPNM IPSecProp Name
LST SGW
ADD SGW
SGW SERVIP4 Fourth Service IP eNodeB MOD SGW
LST SGW
ADD SGW
SERVIP4IPSECFL Fourth Service IP
SGW eNodeB MOD SGW
AG IPSec Flag
LST SGW
ADD SGW
SERVIP4IKEPPER Fourth Service IP
SGW eNodeB MOD SGW
NM IKEPeer Name
LST SGW
ADD SGW
SERVIP4IPSECPR Fourth Service IP
SGW eNodeB MOD SGW
OPNM IPSecProp Name
LST SGW
ADD SGW
SGW DESCRIPTION Description of SGW eNodeB MOD SGW
LST SGW
ADD SGW
SGW CNOPERATORID CnOperatorId eNodeB MOD SGW
LST SGW
ADD X2SERVIP
X2ServIP CN Cabinet No. eNodeB MOD X2SERVIP
LST X2SERVIP
ADD X2SERVIP
X2ServIP SRN Subrack No. eNodeB MOD X2SERVIP
LST X2SERVIP
ADD X2SERVIP
X2ServIP SN Slot No. eNodeB MOD X2SERVIP
LST X2SERVIP
ADD X2SERVIP
LST X2SERVIP
X2ServIP X2SERVIP X2 Service IP eNodeB
MOD X2SERVIP
RMV X2SERVIP
ADD X2SERVIP
X2ServIP IPSECFLAG IPSec Flag eNodeB MOD X2SERVIP
LST X2SERVIP
ADD X2SERVIP
X2ServIP SEGWFLAG SeGW Flag eNodeB MOD X2SERVIP
LST X2SERVIP
ADD X2SERVIP
X2ServIP LOCIKEIP Local IKE IP eNodeB MOD X2SERVIP
LST X2SERVIP
ADD X2SERVIP
X2ServIP IKEPEERNM IKEPeer Name eNodeB MOD X2SERVIP
LST X2SERVIP
ADD X2SERVIP
X2ServIP IPSECPROPNM IPSecProp Name eNodeB MOD X2SERVIP
LST X2SERVIP
ADD X2SIGIP
X2SigIP CN Cabinet No. eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP SRN Subrack No. eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP SN Slot No. eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
LST X2SIGIP
X2SigIP LOCIP Local IP eNodeB
MOD X2SIGIP
RMV X2SIGIP
ADD X2SIGIP
X2SigIP IPSECFLAG IPSec Flag eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP SEGWFLAG SeGW Flag eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP IKEIP Local IKE IP eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP IKEPEERNM IKEPeer Name eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP IPSECPROPNM IPSecProp Name eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP SECLOCIP Second Local IP eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP SECIPSECFLAG Second IPSec Flag eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP SECSEGWFLAG Second SeGW Flag eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP SECLOCIKEIP Second Local IKEIP eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
Second IKEPeer
X2SigIP SECIKEPEERNM eNodeB MOD X2SIGIP
Name
LST X2SIGIP
ADD X2SIGIP
SECIPSECPROPN Second IPSecProp
X2SigIP eNodeB MOD X2SIGIP
M Name
LST X2SIGIP
ADD X2SIGIP
X2SigIP LOCPORT Local Port No. eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP RTOMIN RTO Min Value eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP RTOMAX RTO Max Value eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP RTOINIT RTO Initial Value eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP RTOALPHA RTO Alpha Value eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP RTOBETA RTO Beta Value eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
X2SigIP HBINTER Heart-beat Interval eNodeB MOD X2SIGIP
LST X2SIGIP
ADD X2SIGIP
Max Association
X2SigIP MAXASSOCRETR eNodeB MOD X2SIGIP
Retransmission
LST X2SIGIP
ADD X2SIGIP
Max Path
X2SigIP MAXPATHRETR eNodeB MOD X2SIGIP
Retransmission
LST X2SIGIP
ADD X2SIGIP
Transmit Message
X2SigIP CHKSUMTX eNodeB MOD X2SIGIP
Checksum Flag
LST X2SIGIP
ADD X2SIGIP
Receive Message
X2SigIP CHKSUMRX eNodeB MOD X2SIGIP
Checksum Flag
LST X2SIGIP
ADD X2SIGIP
Checksum
X2SigIP CHKSUMTYPE eNodeB MOD X2SIGIP
Arithmetic Type
LST X2SIGIP
ADD X2SIGIP
SWITCHBACKFLA
X2SigIP Switch Back Flag eNodeB MOD X2SIGIP
G
LST X2SIGIP
ADD X2SIGIP
SWITCHBACKHBN Heart-beat Times
X2SigIP eNodeB MOD X2SIGIP
UM When Switch Back ADD X2ENODEB
LST X2SIGIP
DSP X2ENODEB
X2eNodeB X2ENODEBID X2eNodeB ID eNodeB LST X2ENODEB
MOD X2ENODEB
ADD
RMV X2ENODEB
X2ENODEB
X2eNodeB FIRSTSIGIP First Signalling IP eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
First Signalling IP
X2eNodeB FIRSTIPSECFLAG eNodeB MOD X2ENODEB
IPSec Flag
LST X2ENODEB
ADD X2ENODEB
X2eNodeB FIRSTSEGWFLAG First SeGW Flag eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
X2eNodeB FIRSTIKEIP First IKE IP eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
Second Signalling
X2eNodeB SECSIGIP eNodeB MOD X2ENODEB
IP
LST X2ENODEB
ADD X2ENODEB
X2eNodeB SECIPSECFLAG Second IPSec Flag eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
X2eNodeB SECSEGWFLAG Second SeGW Flag eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
X2eNodeB SECIKEIP Second IKE IP eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
X2eNodeB APPPORT App Port No. eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
X2eNodeB SERVIP1 First Service IP eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
SERVIP1IPSECFL First Service IP
X2eNodeB eNodeB MOD X2ENODEB
AG IPSec Flag
LST X2ENODEB
ADD X2ENODEB
SERVIP1SEGWFL First Service IP
X2eNodeB eNodeB MOD X2ENODEB
AG SeGW Flag
LST X2ENODEB
ADD X2ENODEB
First Service IP IKE
X2eNodeB SERVIP1IKEIP eNodeB MOD X2ENODEB
IP
LST X2ENODEB
ADD X2ENODEB
X2eNodeB SERVIP2 Second Service IP eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
SERVIP2IPSECFL Second Service IP
X2eNodeB eNodeB MOD X2ENODEB
AG IPSec Flag
LST X2ENODEB
ADD X2ENODEB
SERVIP2SEGWFL Second Service IP
X2eNodeB eNodeB MOD X2ENODEB
AG SeGW Flag
LST X2ENODEB
ADD X2ENODEB
Second Service IP
X2eNodeB SERVIP2IKEIP eNodeB MOD X2ENODEB
IKE IP
LST X2ENODEB
ADD X2ENODEB
X2eNodeB SERVIP3 Third Service IP eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
SERVIP3IPSECFL Third Service IP
X2eNodeB eNodeB MOD X2ENODEB
AG IPSecFlag
LST X2ENODEB
ADD X2ENODEB
SERVIP3SEGWFL Third Service IP
X2eNodeB eNodeB MOD X2ENODEB
AG SeGW Flag
LST X2ENODEB
ADD X2ENODEB
Third Service IP
X2eNodeB SERVIP3IKEIP eNodeB MOD X2ENODEB
IKE IP
LST X2ENODEB
ADD X2ENODEB
X2eNodeB SERVIP4 Fourth Service IP eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
SERVIP4IPSECFL Fourth Service IP
X2eNodeB eNodeB MOD X2ENODEB
AG IPSec Flag
LST X2ENODEB
ADD X2ENODEB
SERVIP4SEGWFL Fourth Service IP
X2eNodeB eNodeB MOD X2ENODEB
AG SeGW Flag
LST X2ENODEB
ADD X2ENODEB
Fourth Service IP
X2eNodeB SERVIP4IKEIP eNodeB MOD X2ENODEB
IKE IP
LST X2ENODEB
ADD X2ENODEB
Mobile Country
X2eNodeB MCC eNodeB MOD X2ENODEB
Code
LST X2ENODEB
ADD X2ENODEB
Mobile Network
X2eNodeB MNC eNodeB MOD X2ENODEB
Code
LST X2ENODEB
ADD X2ENODEB
X2eNodeB ENODEBID eNodeB ID eNodeB MOD X2ENODEB
LST X2ENODEB
ADD X2ENODEB
Description of
X2eNodeB DESCRIPTION eNodeB MOD X2ENODEB
X2eNodeB
LST X2ENODEB
ADD X2ENODEB
X2eNodeB CNOPERATORID CnOperatorId eNodeB MOD X2ENODEB
LST X2ENODEB
MOD CERTREQ
CERTREQ COMMNAME Common Name eNodeB
LST CERTREQ
Common Name MOD CERTREQ
CERTREQ USERADDINFO eNodeB
Additional Info. LST CERTREQ
MOD CERTREQ
CERTREQ COUNTRY Country eNodeB
LST CERTREQ
MOD CERTREQ
CERTREQ ORG Organization eNodeB
LST CERTREQ
MOD CERTREQ
CERTREQ ORGUNIT Organizational Unit eNodeB
LST CERTREQ
STATEPROVINCE MOD CERTREQ
CERTREQ State or Province eNodeB
NAME LST CERTREQ
MOD CERTREQ
CERTREQ LOCALITY Locality eNodeB
LST CERTREQ
MOD CERTREQ
CERTREQ KEYUSAGE Key Usage eNodeB
LST CERTREQ
MOD CERTREQ
CERTREQ SIGNALG Signature Algorithm eNodeB
LST CERTREQ
MOD CERTREQ
CERTREQ KEYSIZE Key Size eNodeB UPD DEVCERT
LST CERTREQ
MOD CERTREQ
CERTREQ LOCALNAME Local Name eNodeB
LST CERTREQ
ADD
MOD CERTMK
CERTREQ
CERTREQ LOCALIP Local IP eNodeB DSP CERTMK
LST CERTREQ
REQ DEVCERT
Certificate File RMV CERTMK
CERTMK APPCERT eNodeB
Name UPD DEVCERT
DSP
CERTMK SERIALNO Serial Number eNodeB CMPSESSION
DSP CERTMK
LST CERTMK

CERTMK COMMNAME Common Name eNodeB DSP CERTMK

CERTMK ISSUER Issuer eNodeB DSP CERTMK

CERTMK DATE Expiration Date eNodeB DSP CERTMK

CERTMK EFFECTDATE Effective Date eNodeB DSP CERTMK


DSP APPCERT
LST APPCERT
APPCERT APPTYPE Application Type eNodeB MOD APPCERT
TST
MODAPPCERT
APPCERT
Certificate File LST CERTTYPE
TST APPCERT
APPCERT APPCERT eNodeB
Name DSP APPCERT
LST APPCERT
APPCERT ISSUER Issuer eNodeB DSP APPCERT

APPCERT COMMNAME Common Name eNodeB DSP APPCERT

APPCERT SERIALNO Serial Number eNodeB DSP APPCERT

APPCERT DATE Expiration Date eNodeB DSP APPCERT

APPCERT IKEPEER IKEPeer Name eNodeB TST APPCERT

APPCERT EFFECTDATE Effective Date eNodeB DSP APPCERT

APPCERT STATUS Status eNodeB DSP APPCERT

Application Type
APPCERT SUPPORTTYPE eNodeB None
Supported By NE
ADD CROSSCERT
Certificate File DSP CROSSCERT
CROSSCERT CERTNAME eNodeB
Name RMV CROSSCERT
LST CROSSCERT
CROSSCERT SERIALNO Serial Number eNodeB DSP CROSSCERT
CROSSCERT COMMNAME Common Name eNodeB DSP CROSSCERT

CROSSCERT ISSUER Issuer Name eNodeB DSP CROSSCERT

CROSSCERT DATE Expiring Date eNodeB DSP CROSSCERT

CROSSCERT STATUS Status eNodeB DSP CROSSCERT

CROSSCERT EFFECTDATE Effective Date eNodeB DSP CROSSCERT


ADD TRUSTCERT
Certificate File DSP TRUSTCERT
TRUSTCERT CERTNAME eNodeB
Name RMV TRUSTCERT
LST TRUSTCERT
TRUSTCERT SERIALNO Serial Number eNodeB DSP TRUSTCERT

TRUSTCERT COMMNAME Common Name eNodeB DSP TRUSTCERT

TRUSTCERT ISSUER Issuer Name eNodeB DSP TRUSTCERT

TRUSTCERT DATE Expiring Date eNodeB DSP TRUSTCERT

TRUSTCERT STATUS Status eNodeB DSP TRUSTCERT

TRUSTCERT EFFECTDATE Effective Date eNodeB DSP TRUSTCERT


ADD CRL
DSP CRL
CRL CERTNAME CRL File Name eNodeB
RMV CRL
LST CRL
CRL STATUS Status eNodeB DSP CRL

CRL ISSUER Issuer eNodeB DSP CRL

CRL NEXTDATE Next Update eNodeB DSP CRL

CRL THISDATE This Update eNodeB DSP CRL

ADD CRLTSK
CRLTSK IP IP Address eNodeB
LST CRLTSK
ADD CRLTSK
CRLTSK USR User Name eNodeB
LST CRLTSK

CRLTSK PWD Password eNodeB ADD CRLTSK

ADD CRLTSK
CRLTSK PORT Port No. eNodeB
LST CRLTSK
ADD CRLTSK
CRLTSK FILENAME File Name eNodeB
LST CRLTSK
Using CRL's Next ADD CRLTSK
CRLTSK ISCRLTIME eNodeB
Update LST CRLTSK
CRL Updating ADD CRLTSK
CRLTSK PERIOD eNodeB
Period LST CRLTSK
ADD CRLTSK
CRLTSK TSKID Task ID eNodeB LST CRLTSK
RMV CRLTSK
ADD CRLTSK
CRLTSK CRLGETMETHOD Access Method eNodeB
LST CRLTSK
ADD CRLTSK
CRLTSK SEARCHDN Distinguish Name eNodeB
LST CRLTSK
Certificate Validity SET CERTCHKTSK
CERTCHKTSK ISENABLE eNodeB
Period Checking LST CERTCHKTSK
SET CERTCHKTSK
CERTCHKTSK PERIOD Checking Period eNodeB
LST CERTCHKTSK
SET CERTCHKTSK
CERTCHKTSK ALMRNG Alarm Threshold eNodeB
LST CERTCHKTSK
SET CERTCHKTSK
CERTCHKTSK UPDATEMETHOD Update Method eNodeB
LST CERTCHKTSK
SET CRLPOLICY
CRLPOLICY CRLPOLICY CRL Using Policy eNodeB
LST CRLPOLICY
ECHO Frame MOD GTPU
GTPU TIMEOUTTH eNodeB
Timeout LST GTPU
ECHO Frame MOD GTPU
GTPU TIMEOUTCNT eNodeB
Timeout Count LST GTPU
MOD GTPU
GTPU DSCP DSCP eNodeB
LST GTPU
ADD ACL
LST ACL
ACL ACLID ACL ID eNodeB
MOD ACL
RMV ACL
ADD ACL
ACL ACLDESC Description eNodeB MOD ACL
LST
ADDACL
ACLRULE
LST ACLRULE
ACLRULE ACLID ACL ID eNodeB
MOD ACLRULE
ADD
RMV ACLRULE
ACLRULE
LST ACLRULE
ACLRULE RULEID Rule ID eNodeB
MOD ACLRULE
RMV ACLRULE
ADD ACLRULE
ACLRULE ACTION Action eNodeB
LST ACLRULE
ADD ACLRULE
ACLRULE PT Protocol Type eNodeB
LST ACLRULE
ADD ACLRULE
ACLRULE SIP Source IP Address eNodeB MOD ACLRULE
LST ACLRULE
ADD ACLRULE
ACLRULE SWC Source Wildcard eNodeB MOD ACLRULE
LST ACLRULE
ADD ACLRULE
ACLRULE SMPT Match Source Port eNodeB
LST ACLRULE
Source Port ADD ACLRULE
ACLRULE SOP eNodeB
Operate LST ACLRULE
ADD ACLRULE
ACLRULE SPT1 Source Port 1 eNodeB
LST ACLRULE
ADD ACLRULE
ACLRULE SPT2 Source Port 2 eNodeB
LST ACLRULE
ADD ACLRULE
Destination IP
ACLRULE DIP eNodeB MOD ACLRULE
Address
LST ACLRULE
ADD ACLRULE
Destination
ACLRULE DWC eNodeB MOD ACLRULE
Wildcard
LST ACLRULE
Match Destination ADD ACLRULE
ACLRULE DMPT eNodeB
Port LST ACLRULE
Destination Port ADD ACLRULE
ACLRULE DOP eNodeB
Operate LST ACLRULE
ADD ACLRULE
ACLRULE DPT1 Destination Port 1 eNodeB
LST ACLRULE
ADD ACLRULE
ACLRULE DPT2 Destination Port 2 eNodeB
LST ACLRULE
ADD ACLRULE
ACLRULE MDSCP Match DSCP eNodeB
LST ACLRULE
ADD ACLRULE
ACLRULE DSCP DSCP eNodeB
LST ACLRULE
Match Fragment ADD ACLRULE
ACLRULE MFRG eNodeB ADD BFDSESSION
Message LST ACLRULE
DSP BFDSESSION
MOD
BFDSESSION CN Cabinet No. eNodeB ADD BFDSESSION
BFDSESSION
DSP
RMV BFDSESSION
BFDSESSION
MOD
LST BFDSESSION
BFDSESSION SRN Subrack No. eNodeB ADD BFDSESSION
BFDSESSION
DSP BFDSESSION
RMV BFDSESSION
MOD
LST BFDSESSION
BFDSESSION SN Slot No. eNodeB ADD BFDSESSION
BFDSESSION
DSP
RMV BFDSESSION
BFDSESSION
MOD
LST BFDSESSION
BFDSESSION BFDSN Session ID eNodeB
BFDSESSION
ADD BFDSESSION
RMV BFDSESSION
MOD
BFDSESSION SRCIP Source IP eNodeB LST BFDSESSION
BFDSESSION
ADD BFDSESSION
DSP BFDSESSION
MOD
LST BFDSESSION
BFDSESSION DSTIP Destination IP eNodeB BFDSESSION
DSP BFDSESSION
ADD BFDSESSION
LST BFDSESSION
BFDSESSION HT Hop Type eNodeB DSP BFDSESSION
ADD BFDSESSION
LST BFDSESSION
MOD
BFDSESSION MINTI Min TX Interval eNodeB BFDSESSION
ADD BFDSESSION
DSP BFDSESSION
MOD
LST BFDSESSION
BFDSESSION MINRI Min RX Interval eNodeB BFDSESSION
ADD BFDSESSION
DSP BFDSESSION
MOD
LST BFDSESSION
BFDSESSION DM Detection Multiplier eNodeB BFDSESSION
ADD BFDSESSION
DSP BFDSESSION
MOD
LST BFDSESSION
BFDSESSION CATLOG Session Catalog eNodeB BFDSESSION
DSP BFDSESSION
LST BFDSESSION
ADD BFDSESSION
BFDSESSION DSCP DSCP eNodeB
LST BFDSESSION

BFDSESSION CLEAR Clear Statistic eNodeB DSP BFDSESSION


BFDSESSION FSMState Session State eNodeB DSP BFDSESSION

Active Detecting
BFDSESSION ActualMode eNodeB DSP BFDSESSION
Mode
Active Minimum Tx
BFDSESSION ActualMinTxInterval eNodeB DSP BFDSESSION
Interval
Active Minimum Rx
BFDSESSION ActualMinRxInterval eNodeB DSP BFDSESSION
Interval
Active Detection
BFDSESSION ActualDetectTime eNodeB DSP BFDSESSION
Time

BFDSESSION MyDiscreaminator My Discriminator eNodeB DSP BFDSESSION

BFDSESSION YourDiscreaminator Your Discriminator eNodeB DSP BFDSESSION

Number of TX
BFDSESSION TxPDUCount eNodeB DSP BFDSESSION
PDUs
Number of RX
BFDSESSION RxPDUCount eNodeB DSP BFDSESSION
PDUs
Total Number of Up
BFDSESSION UptoDownCount eNodeB DSP BFDSESSION
to Down Sessions

BFDSESSION Diagnostic Session Diagnosis eNodeB DSP BFDSESSION

BFDSESSION IFIndex Interface Index eNodeB DSP BFDSESSION


ADD CFMBNDIP
CFMBNDIP MDNAME MD Name eNodeB RMV CFMBNDIP
LST CFMBNDIP
ADD CFMBNDIP
CFMBNDIP MANAME MA Name eNodeB RMV CFMBNDIP
LST CFMBNDIP
ADD CFMBNDIP
CFMBNDIP RMEPID RMEP ID eNodeB RMV CFMBNDIP
LST CFMBNDIP
ADD CFMBNDIP
CFMBNDIP BNDIP IP Address eNodeB RMV CFMBNDIP
ADD CFMMA
LST CFMBNDIP
DSP CFMMA
CFMMA MDNAME MD Name eNodeB MOD CFMMA
ADD
RMV CFMMA
CFMMA
DSP CFMMA
LST CFMMA
CFMMA MANAME MA Name eNodeB MOD CFMMA
RMV CFMMA
LST
ADDCFMMA
CFMMA
CFMMA CN Cabinet No. eNodeB
LST CFMMA
ADD CFMMA
CFMMA SRN Subrack No. eNodeB
LST CFMMA
ADD CFMMA
CFMMA SN Slot No. eNodeB
LST CFMMA
ADD CFMMA
CFMMA BNDVLAN Binding VLAN eNodeB DSP CFMMA
LST CFMMA
ADD CFMMA
CFMMA VLANID VLAN ID eNodeB DSP CFMMA
LST CFMMA
ADD CFMMA
MOD CFMMA
CFMMA VLANPRI VLAN Priority eNodeB
DSP CFMMA
ADD CFMMA
LST CFMMA
MOD CFMMA
CFMMA CCMINTL CCM TX Interval eNodeB
DSP CFMMA
LST CFMMA
CFMMA MEPNumber Number of MEPs eNodeB DSP CFMMA

CFMMA RMEPNumber Number of RMEPs eNodeB DSP CFMMA

CFMMA MEPList MEP List eNodeB DSP CFMMA

CFMMA RMEPList RMEP List eNodeB DSP CFMMA


ADD CFMMD
DSP CFMMD
CFMMD MDNAME MD Name eNodeB ADD
RMV CFMMD
CFMMD
DSP CFMMD
LST CFMMD
DSP CFMMA
CFMMD LEVEL MD Level eNodeB
DSP CFMMEP
DSP CFMRMEP
CFMMD MANumber MA Number eNodeB LST
DSP CFMMD
CFMMD

CFMMD MANameList MA List eNodeB DSP CFMCC


ACT CFMMD
ADD CFMMEP
DEA CFMCC
CFMMEP MDNAME MD Name eNodeB ACT
DSP CFMCC
CFMMEP
ADD
RMV CFMMEP
CFMMEP
DEA
LST CFMCC
CFMMEP
CFMMEP MANAME MA Name eNodeB ACT
DSP CFMCC
CFMMEP
ADD
RMV CFMMEP
CFMMEP
DEA CFMCC
LST CFMMEP
CFMMEP MEPID MEP ID eNodeB
DSP CFMMEP
RMV CFMMEP
ADD CFMMEP
LST CFMMEP
CFMMEP CN Cabinet No. eNodeB
LST CFMMEP
ADD CFMMEP
CFMMEP SRN Subrack No. eNodeB
LST CFMMEP
ADD CFMMEP
CFMMEP SN Slot No. eNodeB
LST CFMMEP
ADD CFMMEP
CFMMEP SBT Subboard Type eNodeB
LST CFMMEP
ADD CFMMEP
CFMMEP PT Port Type eNodeB
LST CFMMEP
ADD CFMMEP
CFMMEP PN Port No. eNodeB
LST CFMMEP
DSP CFMMEP
CFMMEP CCSW CC Switch eNodeB
LST CFMMEP

CFMMEP BindingVLAN Binding VLAN eNodeB DSP CFMMEP

CFMMEP VLANID VLAN ID eNodeB DSP CFMMEP

CFMMEP VLANPri VLAN Priority eNodeB DSP CFMMEP


Number of TX CC
CFMMEP TxCCPDU eNodeB DSP CFMMEP
PDUs
Number of RX CC
CFMMEP RxCCPDU eNodeB DSP CFMMEP
PDUs
Number of TX
CFMMEP TxLBPDU eNodeB DSP CFMMEP
Loopback PDUs
Number of RX
CFMMEP RxLBPDU eNodeB DSP CFMMEP
Loopback PDUs
Number of TX Link
CFMMEP TxLTPDU eNodeB DSP CFMMEP
Trace PDUs
Number of RX Link
CFMMEP RxLTPDU eNodeB DSP CFMMEP
Trace PDUs
Number of TX
CFMMEP TxSuccCFMPDU Success CFM eNodeB DSP CFMMEP
PDUs
Number of RX
CFMMEP RxSuccCFMPDU Success CFM eNodeB DSP CFMMEP
PDUs
Number of TX
TxDroppedCFMPD
CFMMEP Dropped CFM eNodeB DSP CFMMEP
U
PDUs
Number of RX
RxDroppedCFMPD
CFMMEP Dropped CFM eNodeB DSP CFMMEP
U
PDUs ADD CFMRMEP
DSP CFMRMEP
CFMRMEP MDNAME MD Name eNodeB
RMV CFMRMEP
ADD CFMRMEP
LST CFMRMEP
DSP CFMRMEP
CFMRMEP MANAME MA Name eNodeB
RMV CFMRMEP
ADD CFMRMEP
LST CFMRMEP
DSP CFMRMEP
CFMRMEP RMEPID RMEP ID eNodeB
RMV CFMRMEP
LST
ADDCFMRMEP
CFMRMEP
CFMRMEP MAC MAC Address eNodeB DSP CFMRMEP
LST CFMRMEP
CFMRMEP Status Status eNodeB DSP CFMRMEP

Actual MAC
CFMRMEP ActualMAC eNodeB DSP CFMRMEP
Address

CFMRMEP BindingVLAN Binding VLAN eNodeB DSP CFMRMEP

CFMRMEP VLANID VLAN ID eNodeB DSP CFMRMEP

Number of RX CCM
CFMRMEP RxCCMPDU eNodeB DSP CFMRMEP
PDUs
Number of Bound
CFMRMEP IPNumber eNodeB DSP CFMRMEP
IPs

CFMRMEP IPList IP Address List eNodeB DSP CFMRMEP


ADD DBGSVR
DSP DBGSVR
DBGSVR SERVICETYPE Service Type eNodeB MOD DBGSVR
ADD
RMV DBGSVR
DBGSVR
DSP DBGSVR
LST DBGSVR
DBGSVR SERVICEPORT Service Port eNodeB MOD DBGSVR
RMV DBGSVR
LST DBGSVR
ADD DBGSVR
MOD DBGSVR
DBGSVR SWITCH Enable Flag eNodeB
DSP DBGSVR
ADD DEVIP
LST DBGSVR
DSP DEVIP
DEVIP CN Cabinet No. eNodeB
RMV DEVIP
ADD DEVIP
LST DEVIP
DSP DEVIP
DEVIP SRN Subrack No. eNodeB
RMV DEVIP
ADD DEVIP
LST DEVIP
DSP DEVIP
DEVIP SN Slot No. eNodeB
RMV DEVIP
ADD DEVIP
LST DEVIP
RMV DEVIP
DEVIP SBT Subboard Type eNodeB
DSP DEVIP
ADD DEVIP
LST
RMVDEVIP
DEVIP
DEVIP PT Port Type eNodeB DSP DEVIP
ADD DEVIP
DSP DHCPRSLT
RMV DEVIP
LST DEVIP
DEVIP PN Port No. eNodeB DSP DEVIP
DSP DHCPRSLT
ADD DEVIP
LST DEVIP
RMV DEVIP
DEVIP IP IP Address eNodeB
DSP DEVIP
LST DEVIP
ADD DEVIP
DEVIP MASK Mask eNodeB DSP
SET DEVIP
LST DEVIP
DHCPRELAYSWIT
CH
DHCPRELAYSWITC ES DHCP Relay Switch eNodeB
LST
DHCPRELAYSWIT
ADD DHCPSVRIP
DHCP Server IP CH DHCPSVRIP
DHCPSVRIP DHCPSVRIP eNodeB RMV
Address
LST DHCPSVRIP
OMCH Auto-
SET DHCPSW
DHCPSW SWITCH Establishment eNodeB
LST DHCPSW
Switch
SET DIFPRI
DIFPRI PRIRULE Priority Rule eNodeB
LST DIFPRI
SET DIFPRI
DIFPRI SIGPRI Signaling Priority eNodeB
LST DIFPRI
SET DIFPRI
DIFPRI OMHIGHPRI OM High Priority eNodeB
LST DIFPRI
SET DIFPRI
DIFPRI OMLOWPRI OM Low Priority eNodeB
LST DIFPRI
SET DIFPRI
DIFPRI PTPPRI IPClock Priority eNodeB
LST DIFPRI
SET DIFPRI
DIFPRI DT1PRI User Data 1 Priority eNodeB
LST DIFPRI
User Data 1
SET DIFPRI
DIFPRI DT1TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 1
SET DIFPRI
DIFPRI DT1PRIMTH Primary Port Load eNodeB
User Data 1 LST DIFPRI
Threshold
Primary To
DT1PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Threshold SET DIFPRI
DIFPRI DT2PRI User Data 2 Priority eNodeB
LST DIFPRI
User Data 2
SET DIFPRI
DIFPRI DT2TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 2
SET DIFPRI
DIFPRI DT2PRIMTH Primary Port Load eNodeB
User Data 2 LST DIFPRI
Threshold
Primary To
DT2PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Threshold SET DIFPRI
DIFPRI DT3PRI User Data 3 Priority eNodeB
LST DIFPRI
User Data 3
SET DIFPRI
DIFPRI DT3TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 3
SET DIFPRI
DIFPRI DT3PRIMTH Primary Port Load eNodeB
User Data 3 LST DIFPRI
Threshold
Primary To
DT3PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Threshold SET DIFPRI
DIFPRI DT4PRI User Data 4 Priority eNodeB
LST DIFPRI
User Data 4
SET DIFPRI
DIFPRI DT4TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 4
SET DIFPRI
DIFPRI DT4PRIMTH Primary Port Load eNodeB
User Data 4 LST DIFPRI
Threshold
Primary To
DT4PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Threshold SET DIFPRI
DIFPRI DT5PRI User Data 5 Priority eNodeB
LST DIFPRI
User Data 5
SET DIFPRI
DIFPRI DT5TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 5
SET DIFPRI
DIFPRI DT5PRIMTH Primary Port Load eNodeB
User Data 5 LST DIFPRI
Threshold
Primary To
DT5PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Threshold SET DIFPRI
DIFPRI DT6PRI User Data 6 Priority eNodeB
LST DIFPRI
User Data 6
SET DIFPRI
DIFPRI DT6TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 6
SET DIFPRI
DIFPRI DT6PRIMTH Primary Port Load eNodeB
User Data 6 LST DIFPRI
Threshold
Primary To
DT6PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Threshold SET DIFPRI
DIFPRI DT7PRI User Data 7 Priority eNodeB
LST DIFPRI
User Data 7
SET DIFPRI
DIFPRI DT7TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 7
SET DIFPRI
DIFPRI DT7PRIMTH Primary Port Load eNodeB
User Data 7 LST DIFPRI
Threshold
Primary To
DT7PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Threshold SET DIFPRI
DIFPRI DT8PRI User Data 8 Priority eNodeB
LST DIFPRI
User Data 8
SET DIFPRI
DIFPRI DT8TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 8
SET DIFPRI
DIFPRI DT8PRIMTH Primary Port Load eNodeB
User Data 8 LST DIFPRI
Threshold
Primary To
DT8PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Threshold SET DIFPRI
DIFPRI DT9PRI User Data 9 Priority eNodeB
LST DIFPRI
User Data 9
SET DIFPRI
DIFPRI DT9TYPE Primary Transport eNodeB
LST DIFPRI
Resource Type
User Data 9
SET DIFPRI
DIFPRI DT9PRIMTH Primary Port Load eNodeB
User Data 9 LST DIFPRI
Threshold
Primary To
DT9PRIMTOSECR SET DIFPRI
DIFPRI Secondary Port eNodeB
ATIOTH LST DIFPRI
Load Ratio
Bit Congestion
Threshold SET DLITFCALG
DLITFCALG BCDLITFCSW Down Link Internal eNodeB
LST DLITFCALG
Flow Control Switch
Packet Congestion
SET DLITFCALG
DLITFCALG PCDLITFCSW Down Link Internal eNodeB
LST DLITFCALG
ADD E1T1
Flow Control Switch
DSP E1T1
E1T1 CN Cabinet No. eNodeB RMV E1T1
ADD E1T1
SET E1T1
DSP E1T1
LST E1T1
E1T1 SRN Subrack No. eNodeB RMV E1T1
ADD E1T1
SET E1T1
DSP E1T1
LST E1T1
E1T1 SN Slot No. eNodeB RMV E1T1
ADD E1T1
SET E1T1
DSP E1T1
LST E1T1
E1T1 PN Port No. eNodeB RMV E1T1
ADD E1T1
SET E1T1
DSP E1T1
LST E1T1
E1T1 PS Port Selection eNodeB RMV E1T1
SET
ADD E1T1
E1T1
LST
SET E1T1
E1T1
E1T1 WORKMODE Work Mode eNodeB
DSP E1T1
ADD E1T1
LST E1T1
SET E1T1
E1T1 FRAME Frame Format eNodeB
DSP E1T1
ADD E1T1
LST E1T1
SET E1T1
E1T1 LNCODE Line Code eNodeB
DSP E1T1
ADD E1T1
LST E1T1
SET E1T1
E1T1 CLKM Clock Mode eNodeB
DSP E1T1
LST E1T1
Link Running
E1T1 LinkRunningStatus eNodeB DSP E1T1
Status
ExecuteLinkTestFla Link Test Execution
E1T1 eNodeB DSP E1T1
g Status

E1T1 UsedFlag Used Flag eNodeB DSP E1T1

E1T1 LoopLeftTime Loop Left Time eNodeB DSP E1T1


ADD E1T1
DSP E1T1
E1T1 SBT Subboard Type eNodeB RMV E1T1
SET E1T1
LST E1T1
E1/T1 BER SET E1T1BER
E1T1BER BTL eNodeB
Threshold Level LST E1T1BER
ACT ETHOAM3AH
DEA ETHOAM3AH
ETHOAM3AH CN Cabinet No. eNodeB
DSP ETHOAM3AH
ACT ETHOAM3AH
LST ETHOAM3AH
DEA ETHOAM3AH
ETHOAM3AH SRN Subrack No. eNodeB
DSP ETHOAM3AH
ACT ETHOAM3AH
LST ETHOAM3AH
DEA ETHOAM3AH
ETHOAM3AH SN Slot No. eNodeB
DSP ETHOAM3AH
ACT ETHOAM3AH
LST ETHOAM3AH
DEA ETHOAM3AH
ETHOAM3AH SBT Subboard Type eNodeB
DSP ETHOAM3AH
ACT ETHOAM3AH
LST ETHOAM3AH
DEA ETHOAM3AH
ETHOAM3AH PT Port Type eNodeB
DSP ETHOAM3AH
ACT ETHOAM3AH
LST ETHOAM3AH
DEA ETHOAM3AH
ETHOAM3AH PN Port No. eNodeB
DSP ETHOAM3AH
LST ETHOAM3AH
ACT ETHOAM3AH
ETHOAM3AH WORKMODE Working Mode eNodeB
LST ETHOAM3AH
ACT ETHOAM3AH
ETHOAM3AH DTPRD Detection Period eNodeB
LST ETHOAM3AH
ACT ETHOAM3AH
ETHOAM3AH PDUSIZE PDU Size eNodeB
LST ETHOAM3AH
ACT ETHOAM3AH
ETHOAM3AH RMTLBFLG Loopback Flag eNodeB
LST ETHOAM3AH
ACT ETHOAM3AH
ETHOAM3AH FLTINDFLG Fault Report Flag eNodeB
LST ETHOAM3AH
Error Frame Event ACT ETHOAM3AH
ETHOAM3AH ERRFRMEVTPRD eNodeB
Duration LST ETHOAM3AH
Error Frame Event ACT ETHOAM3AH
ETHOAM3AH ERRFRMEVTTHD eNodeB
Threshold LST ETHOAM3AH
Error Frame
ERRFRMSCDEVT ACT ETHOAM3AH
ETHOAM3AH Seconds Summary eNodeB
PRD LST ETHOAM3AH
Event Duration
Error Frame
ERRFRMSCDEVTT ACT ETHOAM3AH
ETHOAM3AH Seconds Summary eNodeB
HD LST ETHOAM3AH
Event Threshold
ETHOAM3AH FSMState Current State eNodeB DSP ETHOAM3AH
Number of RX
RxDropOAMPDUC
ETHOAM3AH Dropped eNodeB DSP ETHOAM3AH
ount
OAMPDUs
RxEventOAMPDUC Number of RX
ETHOAM3AH eNodeB DSP ETHOAM3AH
ount Event OAMPDUs
RxFaultOAMPDUC Number of RX Fault
ETHOAM3AH eNodeB DSP ETHOAM3AH
ount OAMPDUs
Number of RX
RxInfoOAMPDUCo
ETHOAM3AH Information eNodeB DSP ETHOAM3AH
unt
OAMPDUs
Number of RX
RxLoopbackOAMP
ETHOAM3AH Loopback Control eNodeB DSP ETHOAM3AH
DUCount
OAMPDUs
RxTotalOAMPDUC Total Number of RX
ETHOAM3AH eNodeB DSP ETHOAM3AH
ount OAMPDUs
Number of TX
TxDropOAMPDUCo
ETHOAM3AH Dropped eNodeB DSP ETHOAM3AH
unt
OAMPDUs
TxEventOAMPDUC Number of TX
ETHOAM3AH eNodeB DSP ETHOAM3AH
ount Event OAMPDUs
TxFaultOAMPDUC Number of TX Fault
ETHOAM3AH eNodeB DSP ETHOAM3AH
ount OAMPDUs
Number of TX
TxInfoOAMPDUCo
ETHOAM3AH Information eNodeB DSP ETHOAM3AH
unt
OAMPDUs
Number of TX
TxLoopbackOAMP
ETHOAM3AH Loopback Control eNodeB DSP ETHOAM3AH
DUCount
OAMPDUs
TxTotalOAMPDUCo Total Number of TX
ETHOAM3AH eNodeB DSP ETHOAM3AH
ADD ETHPORT
unt OAMPDUs
DSP ETHPORT
RMV ETHPORT
ETHPORT CN Cabinet No. eNodeB ADD ETHPORT
RST ETHPORT
DSP ETHPORT
SET ETHPORT
RMV
LST ETHPORT
ETHPORT
ETHPORT SRN Subrack No. eNodeB ADD ETHPORT
RST ETHPORT
DSP ETHPORT
SET ETHPORT
RMV
LST ETHPORT
ETHPORT
ETHPORT SN Slot No. eNodeB ADD ETHPORT
RST ETHPORT
DSP ETHPORT
SET ETHPORT
RMV
LST ETHPORT
ETHPORT
ETHPORT SBT Subboard Type eNodeB ADD ETHPORT
RST ETHPORT
DSP ETHPORT
SET ETHPORT
RMV ETHPORT
LST ETHPORT
ETHPORT PN Port No. eNodeB
RST ETHPORT
ADD ETHPORT
SET
SET ETHPORT
ETHPORT
ETHPORT PA Port Attribute eNodeB LST
DSP ETHPORT
DHCPRSLT
DSP
ADD ETHPORT
ETHPORT
Maximum LST
SET ETHPORT
ETHPORT
ETHPORT MTU eNodeB
Transmission Unit DSP ETHPORT
ADD ETHPORT
LST ETHPORT
SET ETHPORT
ETHPORT SPEED Speed eNodeB
DSP DHCPRSLT
ADD ETHPORT
LST ETHPORT
SET ETHPORT
ETHPORT DUPLEX Duplex eNodeB
DSP DHCPRSLT
ADD ETHPORT
LST ETHPORT
SET ETHPORT
ETHPORT ARPPROXY ARP Proxy eNodeB
DSP ETHPORT
ADD ETHPORT
LST ETHPORT
SET ETHPORT
ETHPORT FC Flow Control eNodeB
DSP ETHPORT
MAC Frame Error LST
ADDETHPORT
ETHPORT
ETHPORT FERAT Rate Occur eNodeB SET ETHPORT
Threshold LST ETHPORT
MAC Frame Error ADD ETHPORT
ETHPORT FERDT Rate Clear eNodeB SET ETHPORT
Threshold LST ETHPORT
ETHPORT MAC MAC Address eNodeB DSP ETHPORT

ETHPORT PortStatus Port Status eNodeB DSP ETHPORT

ETHPORT LoopbackStatus Loopback Status eNodeB DSP ETHPORT

InLoopbackTestMo In Loopback Mode


ETHPORT eNodeB DSP ETHPORT
de or Not
OAM3AHEnableFla Ethernet OAM 3AH
ETHPORT eNodeB DSP ETHPORT
g Flag
Number of RX
ETHPORT RxPackets eNodeB DSP ETHPORT
Packets
Number of RX
ETHPORT RxBytes eNodeB DSP ETHPORT
Bytes
Number of RX CRC
ETHPORT RxCRCError eNodeB DSP ETHPORT
Error Packets

ETHPORT RxFlowRate RX Traffic eNodeB DSP ETHPORT

Number of TX
ETHPORT TxPackets eNodeB DSP ETHPORT
Packets
Number of TX
ETHPORT TxBytes eNodeB DSP ETHPORT
Bytes

ETHPORT TxFlowRate TX Traffic eNodeB DSP ETHPORT

ETHPORT IPNum Number of IPs eNodeB DSP ETHPORT

ETHPORT IPList IP Address List eNodeB DSP ETHPORT

Local Configuration
ETHPORT LocCfgNegoMode eNodeB DSP ETHPORT
Negotiation Mode
Local Actual
ETHPORT LocRealNegoMode eNodeB DSP ETHPORT
Negotiation Mode

ETHPORT LocSpeed Local Speed eNodeB DSP ETHPORT

ETHPORT LocDuplex Local Duplex eNodeB DSP ETHPORT

Peer Actual
ETHPORT PeerNegoMode eNodeB DSP ETHPORT
Negotiation Mode

ETHPORT PeerSpeed Peer Speed eNodeB DSP ETHPORT

ETHPORT PeerDuplex Peer Duplex eNodeB DSP ETHPORT


ADD ETHTRK
DSP ETHTRK
ETHTRK CN Cabinet No. eNodeB MOD ETHTRK
ADD
RMV ETHTRK
ETHTRK
DSP ETHTRK
LST ETHTRK
ETHTRK SRN Subrack No. eNodeB MOD ETHTRK
ADD
RMV ETHTRK
ETHTRK
DSP ETHTRK
LST ETHTRK
ETHTRK SN Slot No. eNodeB MOD ETHTRK
ADD
RMV ETHTRK
ETHTRK
MOD ETHTRK
LST ETHTRK
ETHTRK TN Trunk No. eNodeB RMV ETHTRK
DSP ETHTRK
ADD ETHTRK
LST ETHTRK
MOD ETHTRK
ETHTRK LACP Trunk Type eNodeB
DSP ETHTRK
ADD ETHTRK
LST ETHTRK
MOD ETHTRK
ETHTRK ARPPROXY ARP Proxy eNodeB
DSP ETHTRK
LST ETHTRK
ADD ETHTRK
DSP ETHTRK
ETHTRK SBT Subboard Type eNodeB MOD ETHTRK
RMV ETHTRK
ADD ETHTRK
Max Transmission LST ETHTRK
MOD ETHTRK
ETHTRK MTU eNodeB
Unit DSP ETHTRK
LST ETHTRK
Ethernet Trunk
ETHTRK EthTrunkStatus eNodeB DSP ETHTRK
Status

ETHTRK LocalMAC Local MAC Address eNodeB DSP ETHTRK

Peer System MAC


ETHTRK PeerSysMAC eNodeB DSP ETHTRK
Address
Number of Ethernet
ETHTRK EthTrunkLinkNum eNodeB DSP ETHTRK
Trunk Ports
Ethernet Trunk Port DSP ETHTRK
ETHTRK EthTrunkLinkIDs eNodeB
No. LST ETHTRK
EthTrunkLinkUpNu Number of Active
ETHTRK eNodeB DSP ETHTRK
m Trunk Ports
Active Trunk Port
ETHTRK EthTrunkLinkUpIDs eNodeB DSP ETHTRK
No.
Number of RX
ETHTRK RxPackets eNodeB DSP ETHTRK
Packets
Number of RX
ETHTRK RxBytes eNodeB DSP ETHTRK
Bytes
Number of RX
ETHTRK RxDroppedPackets eNodeB DSP ETHTRK
Dropped Packets
Number of RX
ETHTRK RxDroppedBytes eNodeB DSP ETHTRK
Dropped Bytes
Number of TX
ETHTRK TxPackets eNodeB DSP ETHTRK
Packets
Number of TX
ETHTRK TxBytes eNodeB DSP ETHTRK
Bytes
Number of TX
ETHTRK TxDroppedPackets eNodeB DSP ETHTRK
Dropped Packets
Number of TX
ETHTRK TxDroppedBytes eNodeB DSP ETHTRK
Dropped Bytes

ETHTRK IPNum Number of IPs eNodeB DSP ETHTRK

ETHTRK IPList IP Address List eNodeB DSP ETHTRK


ADD ETHTRKLNK
DSP ETHTRKLNK
ETHTRKLNK CN Cabinet No. eNodeB
RMV ETHTRKLNK
ADD ETHTRKLNK
LST ETHTRKLNK
DSP ETHTRKLNK
ETHTRKLNK SRN Subrack No. eNodeB
RMV ETHTRKLNK
ADD ETHTRKLNK
LST ETHTRKLNK
DSP ETHTRKLNK
ETHTRKLNK SN Slot No. eNodeB
RMV ETHTRKLNK
ADD ETHTRKLNK
LST ETHTRKLNK
DSP ETHTRKLNK
ETHTRKLNK TN Trunk No. eNodeB
RMV ETHTRKLNK
LST ETHTRKLNK
ADD ETHTRKLNK
DSP ETHTRKLNK
ETHTRKLNK PN Ethernet Port No. eNodeB
RMV ETHTRKLNK
LST
ADDETHTRKLNK
ETHTRKLNK
ETHTRKLNK PRI Port Priority eNodeB DSP ETHTRKLNK
LST ETHTRKLNK
ADD ETHTRKLNK
ETHTRKLNK FLAG Master Flag eNodeB
LST ETHTRKLNK
ADD ETHTRKLNK
DSP ETHTRKLNK
ETHTRKLNK SBT Subboard Type eNodeB
RMV ETHTRKLNK
LST ETHTRKLNK
ETHTRKLNK PortStatus Port Status eNodeB DSP ETHTRKLNK

ETHTRKLNK MAC MAC Address eNodeB DSP ETHTRKLNK

Local Timeout
ETHTRKLNK LocalTimeoutMode eNodeB DSP ETHTRKLNK
Mode

ETHTRKLNK PeerTimeoutMode Peer Timeout Mode eNodeB DSP ETHTRKLNK

Number of RX
ETHTRKLNK RxLACPPackets eNodeB DSP ETHTRKLNK
LACP Packets
Number of TX
ETHTRKLNK TxLACPPackets eNodeB DSP ETHTRKLNK
LACP Packets
ADD EXTUDT
User Data Type MOD EXTUDT
EXTUDT EXTUDTNO eNodeB
Number RMV EXTUDT
Extern User Data LST
ADDEXTUDT
ADD EXTUDT
EXTUDTPARAGRP Type Transfer
EXTUDT eNodeB MOD EXTUDT
EXTUDTPARAGRP
ID Parameter Group
Extern User Data LST
LST EXTUDT
ID.
EXTUDTPARAGRP Type Transfer EXTUDTPARAGRP
EXTUDTPARAGRP eNodeB ADD
ID Parameter Group MOD
ID. EXTUDTPARAGRP
EXTUDTPARAGRP
MOD
RMV
EXTUDTPARAGRP PRI Priority eNodeB ADD
EXTUDTPARAGRP
EXTUDTPARAGRP
EXTUDTPARAGRP
LST
MOD
EXTUDTPARAGRP
EXTUDTPARAGRP ACTFACTOR Act Factor eNodeB ADD
EXTUDTPARAGRP
EXTUDTPARAGRP
LST
PRIMTRANRSCTY Primary Transport MOD
EXTUDTPARAGRP
EXTUDTPARAGRP eNodeB ADD
PE Resource Type EXTUDTPARAGRP
EXTUDTPARAGRP
LST
Primary Port Load MOD
EXTUDTPARAGRP
EXTUDTPARAGRP PRIMPTLOADTH eNodeB ADD
Threshold EXTUDTPARAGRP
Primary To EXTUDTPARAGRP
LST
PRIM2SECPTLOA Secondary Port MOD
EXTUDTPARAGRP
EXTUDTPARAGRP eNodeB ADD
DRATH Load Ratio EXTUDTPARAGRP
Threshold EXTUDTPARAGRP
LST
MOD
EXTUDTPARAGRP
EXTUDTPARAGRP FLOWCTRLTYPE Flow Control Type eNodeB
EXTUDTPARAGRP
Resource Group LST
SET
GTRANSPARA LPSCHSW Scheduling Weight eNodeB EXTUDTPARAGRP
GTRANSPARA
Switch LST GTRANSPARA
SET
GTRANSPARA RATECFGTYPE Rate Config Type eNodeB GTRANSPARA
LST GTRANSPARA
SET IKECFG
IKECFG IKELNM Local Name eNodeB DSP IKECFG
LST IKECFG
SET IKECFG
IKECFG IKEKLI Keepalive Interval eNodeB DSP IKECFG
LST IKECFG
SET IKECFG
IKECFG IKEKLT Keepalive Timeout eNodeB DSP IKECFG
LST IKECFG
SET IKECFG
IKECFG DSCP DSCP eNodeB DSP IKECFG
LST IKECFG
IKECFG CabinetNo Cabinet No. eNodeB DSP IKECFG

IKECFG SubrackNo Subrack No. eNodeB DSP IKECFG

IKECFG SlotNo Slot No. eNodeB DSP IKECFG


ADD IKEPEER
DSP IKEPEER
IKEPEER PEERNAME IKE Peer Name eNodeB LST IKEPEER
MOD IKEPEER
ADD IKEPEER
RMV IKEPEER
MOD IKEPEER
IKEPEER PROPID IKE Proposal ID eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER IKEVERSION Version eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER EXCHMODE Exchange Mode eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER IDTYPE Local ID Type eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER REMOTEIP Remote IP Address eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER REMOTENAME Remote Name eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER PKEY Pre-shared Key eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER DPD DPD Mode eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER DPDIDLETIME DPD Idle Time eNodeB
DSP IKEPEER
ADD IKEPEER
LST IKEPEER
DPD
MOD IKEPEER
IKEPEER DPDRETRI Retransmission eNodeB
DSP IKEPEER
Interval ADD IKEPEER
DPD LST IKEPEER
MOD IKEPEER
IKEPEER DPDRETRN Retransmission eNodeB
DSP IKEPEER
Count ADD IKEPEER
LST IKEPEER
MOD IKEPEER
IKEPEER LOCALIP Local IP Address eNodeB
DSP IKEPEER
LST IKEPEER
IKEPEER CabinetNo Cabinet No. eNodeB DSP IKEPEER

IKEPEER SubrackNo Subrack No. eNodeB DSP IKEPEER


ADD
IKEPROPOSAL
IKEPEER SlotNo Slot No. eNodeB DSP
DSP IKEPEER
IKEPROPOSAL
ADD
LST
IKEPROPOSAL PROPID Proposal ID eNodeB IKEPROPOSAL
IKEPROPOSAL
MOD
MOD
Encryption IKEPROPOSAL
IKEPROPOSAL
IKEPROPOSAL ENCALG eNodeB
Algorithm DSP
RMV
IKEPROPOSAL
IKEPROPOSAL
LST
IKEPROPOSAL
ADD
IKEPROPOSAL
MOD
Authentication ADD
IKEPROPOSAL
IKEPROPOSAL AUTHALG eNodeB IKEPROPOSAL
Algorithm DSP
MOD
IKEPROPOSAL
Authentication ADD
IKEPROPOSAL
IKEPROPOSAL AUTHMETH eNodeB LST
IKEPROPOSAL
Method DSP
IKEPROPOSAL
MOD
IKEPROPOSAL
Diffie-Hellman ADD
IKEPROPOSAL
IKEPROPOSAL DHGRP eNodeB LST
IKEPROPOSAL
Group DSP
IKEPROPOSAL
MOD
IKEPROPOSAL
ISAKMP SA ADD
IKEPROPOSAL
IKEPROPOSAL DURATION eNodeB LST
IKEPROPOSAL
Duration DSP
IKEPROPOSAL
MOD
IKEPROPOSAL
IKEPROPOSAL
LST
IKEPROPOSAL PRFALG PRF Algorithm eNodeB
DSP
IKEPROPOSAL
IKEPROPOSAL
DSP
LST
IKEPROPOSAL CabinetNo Cabinet No. eNodeB
IKEPROPOSAL
IKEPROPOSAL
DSP
IKEPROPOSAL SubrackNo Subrack No. eNodeB
IKEPROPOSAL
DSP
IKEPROPOSAL SlotNo Slot No. eNodeB
IKEPROPOSAL
ADD IP2RSCGRP
IP2RSCGRP CN Cabinet No. eNodeB RMV IP2RSCGRP
LST IP2RSCGRP
ADD IP2RSCGRP
IP2RSCGRP SRN Subrack No. eNodeB RMV IP2RSCGRP
LST IP2RSCGRP
ADD IP2RSCGRP
IP2RSCGRP SN Slot No. eNodeB RMV IP2RSCGRP
LST IP2RSCGRP
ADD IP2RSCGRP
Transmission
IP2RSCGRP RSCGRPID eNodeB RMV IP2RSCGRP
Resource Group ID
LST IP2RSCGRP
ADD IP2RSCGRP
IP2RSCGRP DSTIP Destination IP eNodeB RMV IP2RSCGRP
LST IP2RSCGRP
ADD IP2RSCGRP
IP2RSCGRP DSTMASK Mask eNodeB RMV IP2RSCGRP
LST IP2RSCGRP
Transmission ADD IP2RSCGRP
IP2RSCGRP BEAR Resource Group eNodeB RMV IP2RSCGRP
Bear Type LST IP2RSCGRP
ADD IP2RSCGRP
IP2RSCGRP SBT Subboard Type eNodeB RMV IP2RSCGRP
LST IP2RSCGRP
ADD IP2RSCGRP
IP2RSCGRP PT Bearing Port Type eNodeB RMV IP2RSCGRP
LST IP2RSCGRP
ADD IP2RSCGRP
IP2RSCGRP PN Bearing Port No. eNodeB RMV IP2RSCGRP
ADD IPPATH
LST IP2RSCGRP
DSP IPPATH
IPPATH PATHID IP Path ID eNodeB MOD IPPATH
RMV IPPATH
ADD IPPATH
LST IPPATH
IPPATH CN Cabinet No. eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH SRN Subrack No. eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH SN Slot No. eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH PT Port Type eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH PN Port No. eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH PATHTYPE Path Type eNodeB
LST IPPATH
ADD IPPATH
IPPATH DSCP DSCP eNodeB
LST IPPATH
ADD IPPATH
IPPATH LOCALIP Local IP eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH PEERIP Peer IP eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH ANI Adjacent Node ID eNodeB MOD IPPATH
LST
ADDIPPATH
IPPATH
Transport Resource MOD IPPATH
IPPATH QT eNodeB
Type DSP IPPATH
LST
ADDIPPATH
IPPATH
IPPATH APPTYPE Application Type eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH PATHCHK Path Check eNodeB MOD IPPATH
LST IPPATH
RealtimeTxBandwid Realtime TX
IPPATH eNodeB DSP IPPATH
th Bandwidth
RealtimeRxBandwi Realtime RX
IPPATH eNodeB DSP IPPATH
dth Bandwidth
NonRealtimeTxBan Non-Realtime TX
IPPATH eNodeB DSP IPPATH
dwidth Bandwidth
NonRealtimeRxBan Non-Realtime RX
IPPATH eNodeB DSP IPPATH
dwidth Bandwidth
Non-Realtime
NonRealtimeReserv
IPPATH Reserved TX eNodeB DSP IPPATH
edTxBandwidth
Bandwidth
Non-Realtime
NonRealtimeReserv
IPPATH Reserved RX eNodeB DSP IPPATH
edRxBandwidth
Bandwidth
IP Path Check
IPPATH IppathCheckResult eNodeB DSP IPPATH
Result
ADD IPPATH
Transmission
IPPATH RSCGRPID eNodeB MOD IPPATH
Resource Group ID
LST IPPATH
ADD IPPATH
IPPATH DESCRI Description Info eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
IPPATH SBT Subboard Type eNodeB MOD IPPATH
LST IPPATH
ADD IPPATH
Join Transmission
IPPATH JNRSCGRP eNodeB MOD IPPATH
Resource Group
LST
ADDIPPATH
IPPATHRT
DSP IPPATHRT
IPPATHRT SRCIP Source IP eNodeB
RMV IPPATHRT
ADD IPPATHRT
LST IPPATHRT
DSP IPPATHRT
IPPATHRT DSTIP Destination IP eNodeB
RMV IPPATHRT
LST IPPATHRT
ADD IPPATHRT
Transport Resource
IPPATHRT TRANRSCTYPE eNodeB DSP IPPATHRT
Type
LST IPPATHRT
ADD
ADD IPPATHRT
IPPATHRT NEXTHOPIP Next Hop IP eNodeB DSP IPPATHRT
IPPMSESSION
LST IPPATHRT
DSP
IPPMSESSION
IPPMSESSION IPPMSN IP PM Session ID eNodeB ADD
RMV
IPPMSESSION
IPPMSESSION
DSP
LST
IPPMSESSION LOCALIP Local IP eNodeB ADD
IPPMSESSION
IPPMSESSION
IPPMSESSION
LST
DSP
IPPMSESSION
IPPMSESSION PEERIP Peer IP eNodeB ADD
IPPMSESSION
IPPMSESSION
LST
DSP
IPPMSESSION
IPPMSESSION IPPMDSCP DSCP eNodeB ADD
IPPMSESSION
IPPMSESSION
LST
DSP
IPPMSESSION
IPPMSESSION DIR Activate Direction eNodeB
IPPMSESSION
LST
DSP
IPPMSESSION
IPPMSESSION TimeDelay Round Trip Time eNodeB
IPPMSESSION
DSP
IPPMSESSION RxJitter RX Jitter eNodeB
IPPMSESSION
DSP
IPPMSESSION TxJitter TX Jitter eNodeB
IPPMSESSION
DSP
IPPMSESSION RxLossRate RX Loss Rate eNodeB
IPPMSESSION
DSP
IPPMSESSION TxLossRate TX Loss Rate eNodeB
IPPMSESSION
DSP
IPPMSESSION IppmUpActState Activate State(Up) eNodeB
IPPMSESSION
Activate DSP
IPPMSESSION IppmDownActState eNodeB ADD
State(Down) IPPMSESSION
IPPMSESSION
DSP
IPPMSESSION IPPMTYPE IP PM Type eNodeB ADD
IPPMSESSION
IPPMSESSION
LST
DSP
IPPMSESSION
IPPMSESSION BINDPATH Bind IP Path eNodeB ADD
IPPMSESSION
IPPMSESSION
LST
DSP
IPPMSESSION
IPPMSESSION PATHID IP Path ID eNodeB
IPPMSESSION
LST
DLDscpChangeFla DSCP Change DSP
IPPMSESSION
IPPMSESSION eNodeB
g Flag(Down) IPPMSESSION
DSCP Initial DSP
IPPMSESSION DLPreDscp eNodeB
Value(Down) IPPMSESSION
DSCP Changed DSP
IPPMSESSION DLModiDscp eNodeB
Value(Down) IPPMSESSION
DSCP Changed
DscpChangeDateTi DSP
IPPMSESSION Date And eNodeB
me IPPMSESSION
ADD IPRT
Time(Down)
DSP IPRT
IPRT CN Cabinet No. eNodeB MOD IPRT
ADD
RMV IPRT
IPRT
DSP IPRT
LST IPRT
IPRT SRN Subrack No. eNodeB MOD IPRT
ADD
RMV IPRT
IPRT
DSP IPRT
LST IPRT
IPRT SN Slot No. eNodeB MOD IPRT
RMV IPRT
LST IPRT
ADD IPRT
MOD IPRT
IPRT SBT Subboard Type eNodeB
RMV IPRT
ADD IPRT
LST IPRT
MOD IPRT
IPRT IFT Port Type eNodeB
RMV IPRT
ADD IPRT
LST IPRT
MOD IPRT
IPRT IFNO Port No. eNodeB
RMV IPRT
ADD IPRT
LST
MODIPRT
IPRT
IPRT RTTYPE Route Type eNodeB RMV IPRT
ADD IPRT
DSP IPRT
MOD IPRT
LST IPRT
IPRT DSTIP Destination IP eNodeB RMV IPRT
ADD IPRT
DSP IPRT
MOD IPRT
LST IPRT
IPRT DSTMASK Mask eNodeB RMV IPRT
ADD IPRT
DSP IPRT
MOD IPRT
LST IPRT
IPRT NEXTHOP Next Hop IP eNodeB RMV IPRT
DSP IPRT
ADD IPRT
LST IPRT
IPRT PREF Preference eNodeB DSP IPRT
LST IPRT
IPRT RTRouteType Protocol eNodeB DSP IPRT
ADD IPRT
IPRT DESCRI Description Info eNodeB MOD IPRT
LST IPRT
IPRT ActualPortType Actual Port Type eNodeB DSP IPRT

IPRT ActualPortNo Actual Port No. eNodeB DSP IPRT


ADD IPSECBIND
IPSECBIND CN Cabinet No. eNodeB RMV IPSECBIND
LST IPSECBIND
ADD IPSECBIND
IPSECBIND SRN Subrack No. eNodeB RMV IPSECBIND
LST IPSECBIND
ADD IPSECBIND
IPSECBIND SN Slot No. eNodeB RMV IPSECBIND
LST IPSECBIND
ADD IPSECBIND
IPSECBIND SBT Subboard Type eNodeB RMV IPSECBIND
LST IPSECBIND
ADD IPSECBIND
IPSECBIND PT Port Type eNodeB RMV IPSECBIND
LST IPSECBIND
ADD IPSECBIND
IPSECBIND PN Port No. eNodeB RMV IPSECBIND
LST
ADDIPSECBIND
ADD IPSECBIND
IPSECPOLICY
IPSECBIND SPGN Policy Group Name eNodeB
LST
DSP IPSECBIND
ADD
IPSECPOLICY
IPSECPOLICY SPGN Policy Group Name eNodeB IPSECPOLICY
LST IPSECPOLICY
DSP
MOD
IPSECPOLICY
IPSECPOLICY
IPSec Sequence ADD
IPSECPOLICY SPSN eNodeB LST
RMV IPSECPOLICY
No. IPSECPOLICY
MOD
IPSECPOLICY
MOD
IPSECPOLICY
IPSECPOLICY ACLID ACL ID eNodeB ADD
IPSECPOLICY
RMV
IPSECPOLICY
DSP
IPSECPOLICY
MOD
IPSECPOLICY
IPSec Proposal
IPSECPOLICY PROPNAME eNodeB IPSECPOLICY
LST IPSECPOLICY
Name
DSP
IPSECPOLICY
LST IPSECPOLICY
ADD
IPSECPOLICY
MOD
IPSECPOLICY PEERNAME IKE Peer Name eNodeB ADD
IPSECPOLICY
IPSECPOLICY
DSP
MOD
IPSECPOLICY
Perfect Forward ADD
IPSECPOLICY PFS eNodeB IPSECPOLICY
LST IPSECPOLICY
Secrecy IPSECPOLICY
DSP
MOD
IPSECPOLICY
IPSECPOLICY LTCFG SA Duration Mode eNodeB ADD
IPSECPOLICY
LST IPSECPOLICY
IPSECPOLICY
DSP
MOD
IPSECPOLICY
Lifetime Based On ADD
IPSECPOLICY LTS eNodeB IPSECPOLICY
LST IPSECPOLICY
Time IPSECPOLICY
DSP
MOD
IPSECPOLICY
Lifetime Based On
IPSECPOLICY LTKB eNodeB IPSECPOLICY
LST IPSECPOLICY
Traffic
DSP
IPSECPOLICY
DSP
IPSECPOLICY CabinetNo Cabinet No. eNodeB LST IPSECPOLICY
IPSECPOLICY
DSP
IPSECPOLICY SubrackNo Subrack No. eNodeB
IPSECPOLICY
ADD
IPSECPROPOSAL
DSP
IPSECPOLICY SlotNo Slot No. eNodeB DSP
IPSECPOLICY
IPSECPROPOSAL
IPSec Proposal ADD
LST
IPSECPROPOSAL PROPNAME eNodeB IPSECPROPOSAL
Name IPSECPROPOSAL
MOD
MOD
Encapsulation ADD
IPSECPROPOSAL
IPSECPROPOSAL ENCAPMODE eNodeB IPSECPROPOSAL
IPSECPROPOSAL
Mode DSP
RMV
MOD
IPSECPROPOSAL
IPSECPROPOSAL
ADD
IPSECPROPOSAL
IPSECPROPOSAL TRANMODE Transform eNodeB LST
IPSECPROPOSAL
DSP
IPSECPROPOSAL
MOD
IPSECPROPOSAL
AH Authentication ADD
IPSECPROPOSAL
IPSECPROPOSAL AHAUTHALG eNodeB LST
IPSECPROPOSAL
Algorithm DSP
IPSECPROPOSAL
MOD
IPSECPROPOSAL
ESP Authentication ADD
IPSECPROPOSAL
IPSECPROPOSAL ESPAUTHALG eNodeB LST
IPSECPROPOSAL
Algorithm DSP
IPSECPROPOSAL
MOD
IPSECPROPOSAL
ESP Encryption IPSECPROPOSAL
LST
IPSECPROPOSAL ESPENCALG eNodeB
Algorithm DSP
IPSECPROPOSAL
IPSECPROPOSAL
DSP
LST
IPSECPROPOSAL CabinetNo Cabinet No. eNodeB
IPSECPROPOSAL
IPSECPROPOSAL
DSP
IPSECPROPOSAL SubrackNo Subrack No. eNodeB
IPSECPROPOSAL
DSP
IPSECPROPOSAL SlotNo Slot No. eNodeB
IPSECPROPOSAL
DSP
LOCALETHPORT ConfigStatus Config Status eNodeB
LOCALETHPORT
DSP
LOCALETHPORT PortStatus Port Status eNodeB
LOCALETHPORT
Number of RX Error DSP
LOCALETHPORT RxError eNodeB
Packets LOCALETHPORT
Number of RX DSP
LOCALETHPORT RxPackets eNodeB
Packets LOCALETHPORT
Number of TX Error DSP
LOCALETHPORT TxError eNodeB
Packets LOCALETHPORT
Number of TX DSP
LOCALETHPORT TxPackets eNodeB
Packets LOCALETHPORT
SET LOCALIP
LOCALIP IP IP Address eNodeB DSP LOCALIP
LST LOCALIP
SET LOCALIP
LOCALIP MASK Mask eNodeB DSP LOCALIP
LST LOCALIP
SET LR
LR CN Cabinet No. eNodeB
LST LR
SET LR
LR SRN Subrack No. eNodeB
LST LR
SET LR
LR SN Slot No. eNodeB
LST LR
SET LR
LR PT Port Type eNodeB
LST LR
SET LR
LR PN Port No. eNodeB
LST LR
SET LR
LR LRSW LR Switch eNodeB
LST LR
UL Committed SET LR
LR CIR eNodeB
Information Rate LST LR
Committed Burst SET LR
LR CBS eNodeB
Size LST LR
SET LR
LR EBS Excess Burst Size eNodeB
LST LR
SET LR
LR SBT Subboard Type eNodeB
LST LR
DL Committed SET LR
LR DLCIR eNodeB
Information Rate LST LR
ADD MPGRP
DSP MPGRP
MPGRP CN Cabinet No. eNodeB RMV MPGRP
ADD MPGRP
RST MPGRP
DSP MPGRP
LST MPGRP
MPGRP SRN Subrack No. eNodeB RMV MPGRP
ADD MPGRP
RST MPGRP
DSP MPGRP
LST MPGRP
MPGRP SN Slot No. eNodeB RMV MPGRP
ADD MPGRP
RST MPGRP
DSP MPGRP
LST MPGRP
MPGRP MPGRPN MLPPP Group No. eNodeB RMV MPGRP
RST MPGRP
ADD MPGRP
LST MPGRP
MPGRP MCPPP Multi-Class PPP eNodeB DSP MPGRP
LST MPGRP
ADD MPGRP
MPGRP AUTH Authentication Type eNodeB
LST MPGRP
ADD MPGRP
MPGRP UN User Name eNodeB
LST MPGRP
ADD MPGRP
MPGRP PWD Password eNodeB
LST MPGRP
ADD MPGRP
MPGRP LOCALIP Local IP eNodeB DSP MPGRP
LST MPGRP
ADD MPGRP
MPGRP IPMASK Mask eNodeB DSP MPGRP
LST MPGRP
ADD MPGRP
MPGRP PEERIP Peer IP eNodeB DSP MPGRP
LST MPGRP
MP/MC Header ADD MPGRP
MPGRP MHO eNodeB
Option LST MPGRP
ADD MPGRP
MPGRP MUXCP PPPMUX eNodeB DSP MPGRP
LST MPGRP
MLPPP Fragment ADD MPGRP
MPGRP FRAGSIZE eNodeB
Size LST MPGRP
PPP Mux Subframe ADD MPGRP
MPGRP MAXSFLEN eNodeB
Max Length LST MPGRP
PPP Muxframe Max ADD MPGRP
MPGRP MAXMFLEN eNodeB
Length LST MPGRP
PPPMUX Combine ADD MPGRP
MPGRP MUXTIME eNodeB
Timeout LST MPGRP
ADD MPGRP
MPGRP MCCLASS MCPPP Class eNodeB
LST MPGRP
ADD MPGRP
IP Header
MPGRP IPHC eNodeB DSP MPGRP
Compression
LST MPGRP
MLPPP Packets
ADD MPGRP
MPGRP MPDAAT Discard Alarm eNodeB
LST MPGRP
Appear
MLPPP Threshold
Packets
Discard Alarm ADD MPGRP
MPGRP MPDADT eNodeB
Disappear LST MPGRP
Threshold
MLPPP Group
MPGRP MPGroupStatus eNodeB DSP MPGRP
Status

MPGRP IPCPSTATUS IPCP Status eNodeB DSP MPGRP

MPGRP PPPMUXSTATUS PPPMUX Status eNodeB DSP MPGRP

Local IP Negotiation
MPGRP LOCALIPNEGRLT eNodeB DSP MPGRP
Result
Local IP Mask
MPGRP IPMASKNEGRLT eNodeB DSP MPGRP
Negotiation Result
Peer IP Negotiation
MPGRP PEERIPNEGRLT eNodeB DSP MPGRP
Result
Multi-Class PPP
MPGRP MCPPPNEGRLT eNodeB DSP MPGRP
Negotiation Result
Maximum Receive
MPGRP MRUNEGRLT Unit Negotiation eNodeB DSP MPGRP
Result
PPPMUX
MPGRP MUXNEGRLT eNodeB DSP MPGRP
Negotiation Result
ACFC Negotiation
MPGRP ACFCNEGRLT eNodeB DSP MPGRP
Result
PFC Negotiation
MPGRP PFCNEGRLT eNodeB DSP MPGRP
Result
IP Header
MPGRP IPHCNEGRLT Compression eNodeB DSP MPGRP
Negotiation Result
Number of RX
MPGRP RXPKT eNodeB DSP MPGRP
Packets
Number of TX
MPGRP TXPKT eNodeB DSP MPGRP
Packets

MPGRP RXFLOW RX Flow eNodeB DSP MPGRP

MPGRP TXFLOW TX Flow eNodeB DSP MPGRP

MPGRP IPNum Number of IPs eNodeB DSP MPGRP

MPGRP IPList IP Address List eNodeB DSP MPGRP


ADD MPGRP
DSP MPGRP
MPGRP SBT Subboard Type eNodeB RMV MPGRP
RST MPGRP
Number of RX LST MPGRP
MPGRP RXBYTE eNodeB DSP MPGRP
Bytes
Number of RX Drop
MPGRP RXDROPPKT eNodeB DSP MPGRP
Packets
Number of RX Drop
MPGRP RXDROPBYTE eNodeB DSP MPGRP
Bytes
Number of TX
MPGRP TXBYTE eNodeB DSP MPGRP
Bytes
Number of TX Drop
MPGRP TXDROPPKT eNodeB DSP MPGRP
Packets
Number of TX Drop
MPGRP TXDROPBYTE eNodeB DSP MPGRP
Bytes
ADD MPLNK
DSP MPLNK
MPLNK CN Cabinet No. eNodeB
RMV MPLNK
ADD MPLNK
LST MPLNK
DSP MPLNK
MPLNK SRN Subrack No. eNodeB
RMV MPLNK
ADD MPLNK
LST MPLNK
DSP MPLNK
MPLNK SN Slot No. eNodeB
RMV MPLNK
ADD MPLNK
LST MPLNK
DSP MPLNK
MPLNK PPPLNKN MLPPP Link No. eNodeB
RMV MPLNK
LST
ADDMPLNK
MPLNK
MPLNK MPGRPN MLPPP Group No. eNodeB DSP MPLNK
LST MPLNK
ADD MPLNK
MPLNK E1T1SRN E1/T1 Subrack No. eNodeB
LST MPLNK
ADD MPLNK
MPLNK E1T1SN E1/T1 Slot No. eNodeB
LST MPLNK
ADD MPLNK
MPLNK E1T1PN E1/T1 Port No. eNodeB
LST MPLNK
ADD MPLNK
MPLNK TSN Timeslot No. eNodeB
LST MPLNK
ADD MPLNK
Maximum Receive
MPLNK MRU eNodeB DSP MPLNK
Unit
LST MPLNK
ADD MPLNK
Protocol Field
MPLNK PFC eNodeB DSP MPLNK
Compression
LST MPLNK
Address and ADD MPLNK
MPLNK ACFC Control Field eNodeB DSP MPLNK
Compression LST MPLNK
ADD MPLNK
MPLNK RESTARTTMR Negotiation Time eNodeB
LST MPLNK
ADD MPLNK
DSP MPLNK
MPLNK SBT Subboard Type eNodeB
RMV MPLNK
LST MPLNK
MLPPP Group ADD MPLNK
MPLNK MPGRPSBT eNodeB
Subboard Type LST MPLNK

MPLNK MPLNKSTATUS MLPPP Link Status eNodeB DSP MPLNK

MPLNK LCPSTATUS LCP Status eNodeB DSP MPLNK


Maximum Receive
MPLNK MRUNEGRLT Unit Negotiation eNodeB DSP MPLNK
Result
PFC Negotiation
MPLNK PFCNEGRLT eNodeB DSP MPLNK
Result
ACFC Negotiation
MPLNK ACFCNEGRLT eNodeB DSP MPLNK
Result
E1/T1 Subboard ADD MPLNK
MPLNK E1T1SBT eNodeB
Type LST MPLNK
Number of RX
MPLNK RXPKT eNodeB DSP MPLNK
Packets
Number of RX
MPLNK RXBYTE eNodeB DSP MPLNK
Bytes
Number of RX Drop
MPLNK RXDROPPKT eNodeB DSP MPLNK
Packets
Number of RX Drop
MPLNK RXDROPBYTE eNodeB DSP MPLNK
Bytes
Number of TX
MPLNK TXPKT eNodeB DSP MPLNK
Packets
Number of TX
MPLNK TXBYTE eNodeB DSP MPLNK
Bytes
Number of TX Drop
MPLNK TXDROPPKT eNodeB DSP MPLNK
Packets
Number of TX Drop
MPLNK TXDROPBYTE eNodeB DSP MPLNK
Bytes ADD OMCH
DSP OMCH
OMCH FLAG Master/Slave Flag eNodeB MOD OMCH
ADD
RMV OMCH
OMCH
MOD OMCH
LST OMCH
OMCH IP Local IP eNodeB DSP DHCPRSLT
ADD OMCH
DSP OMCH
MOD OMCH
LST OMCH
OMCH MASK Local Mask eNodeB DSP DHCPRSLT
ADD OMCH
DSP OMCH
MOD OMCH
LST OMCH
OMCH PEERIP Peer IP eNodeB DSP DHCPRSLT
DSP OMCH
LST OMCH
ADD OMCH
MOD OMCH
OMCH PEERMASK Peer Mask eNodeB DSP DHCPRSLT
ADD OMCH
DSP OMCH
MOD OMCH
LST OMCH
OMCH CN Cabinet No. eNodeB DSP DHCPRSLT
ADD OMCH
DSP OMCH
MOD OMCH
LST OMCH
OMCH SRN Subrack No. eNodeB DSP DHCPRSLT
ADD OMCH
DSP OMCH
MOD OMCH
LST OMCH
OMCH SN Slot No. eNodeB DSP DHCPRSLT
ADD OMCH
DSP OMCH
MOD OMCH
LST OMCH
OMCH BEAR Bearer Type eNodeB DSP DHCPRSLT
DSP OMCH
ADD OMCH
LST OMCH
MOD OMCH
OMCH BRT Binding Route eNodeB
DSP OMCH
ADD OMCH
LST OMCH
MOD OMCH
OMCH DSTIP Destination IP eNodeB
DSP OMCH
ADD OMCH
LST
MODOMCH
OMCH
OMCH DSTMASK Destination Mask eNodeB DSP DHCPRSLT
DSP
ADD OMCH
OMCH
LST
MODOMCH
OMCH
OMCH RT Route Type eNodeB
DSP OMCH
ADD OMCH
LST OMCH
MOD OMCH
OMCH PREF Preference eNodeB
DSP OMCH
ADD OMCH
LST OMCH
MOD OMCH
OMCH NEXTHOP Next Hop IP eNodeB
DSP OMCH
LST OMCH
OMCH Status OM Channel Status eNodeB DSP OMCH

OMCH UsedState Used State eNodeB DSP OMCH


ADD OMCH
ADD
MOD OMCH
OMCH SBT Subboard Type eNodeB PACKETFILTER
DSP OMCH
DSP
LST OMCH
ADD
PACKETFILTER
PACKETFILTER CN Cabinet No. eNodeB PACKETFILTER
RMV
DSP
PACKETFILTER
ADD
PACKETFILTER
PACKETFILTER SRN Subrack No. eNodeB LST
PACKETFILTER
RMV
PACKETFILTER
DSP
PACKETFILTER
ADD
PACKETFILTER
PACKETFILTER SN Slot No. eNodeB LST
PACKETFILTER
RMV
PACKETFILTER
DSP
PACKETFILTER
ADD
PACKETFILTER
PACKETFILTER PT Port Type eNodeB LST
PACKETFILTER
RMV
PACKETFILTER
DSP
PACKETFILTER
PACKETFILTER
LST
PACKETFILTER PN Port No. eNodeB ADD
RMV
PACKETFILTER
PACKETFILTER
PACKETFILTER
DSP
LST
PACKETFILTER ACLID ACL ID eNodeB ADD
PACKETFILTER
PACKETFILTER
PACKETFILTER
LST
ADD
DSP
PACKETFILTER MB Match Behavior eNodeB PACKETFILTER
PACKETFILTER
PACKETFILTER
DSP
LST
PACKETFILTER
PACKETFILTER
PACKETFILTER SBT Subboard Type eNodeB
RMV
PACKETFILTER
Number of TX DSP
LST
PACKETFILTER TxPackets eNodeB
Packets PACKETFILTER
PACKETFILTER
Number of RX DSP
PACKETFILTER RxPackets eNodeB
Packets PACKETFILTER
Number of TX DSP
PACKETFILTER TxPermitPacket eNodeB
Permit Packets PACKETFILTER
Number of RX DSP
PACKETFILTER RxPermitPacket eNodeB
Permit Packets PACKETFILTER
Number of TX Deny DSP
PACKETFILTER TxDenyPacket eNodeB
Packets PACKETFILTER
Number of RX Deny DSP
PACKETFILTER RxDenyPacket eNodeB
Packets PACKETFILTER
Bytes of TX DSP
PACKETFILTER TxBytes eNodeB
Packets PACKETFILTER
Bytes of RX DSP
PACKETFILTER RxBytes eNodeB
Packets PACKETFILTER
Bytes of TX Permit DSP
PACKETFILTER TxPermitBytes eNodeB
Packets PACKETFILTER
Bytes of RX Permit DSP
PACKETFILTER RxPermitBytes eNodeB
Packets PACKETFILTER
Bytes of TX Deny DSP
PACKETFILTER TxDenyBytes eNodeB
Packets PACKETFILTER
Bytes of RX Deny DSP
PACKETFILTER RxDenyBytes eNodeB
Packets PACKETFILTER
Bytes of RX
DSP
PACKETFILTER RxDefaultBytes Packets Matched eNodeB
PACKETFILTER
Default Behavior
Number of RX
DSP
PACKETFILTER RxDefaultPackets Packets Matched eNodeB
PACKETFILTER
Default Behavior
ADD PINGFILTER
PINGFILTER IP IP Address eNodeB RMV PINGFILTER
LST PINGFILTER
ADD PINGFILTER
PINGFILTER MASK Mask eNodeB RMV
DSP PINGFILTER
LST PINGFILTER
PORTSECURITY
SET
PORTSECURITY CN Cabinet No. eNodeB DSP
PORTSECURITY
PORTSECURITY
LST
SET
PORTSECURITY
PORTSECURITY SRN Subrack No. eNodeB DSP
PORTSECURITY
PORTSECURITY
LST
SET
PORTSECURITY
PORTSECURITY SN Slot No. eNodeB DSP
PORTSECURITY
PORTSECURITY
LST
SET
PORTSECURITY
PORTSECURITY SBT Subboard Type eNodeB DSP
PORTSECURITY
PORTSECURITY
LST
SET
PORTSECURITY
PORTSECURITY PT Port Type eNodeB DSP
PORTSECURITY
PORTSECURITY
LST
SET
PORTSECURITY
PORTSECURITY PN Port No. eNodeB SET
PORTSECURITY
PORTSECURITY
LST
DSP
PORTSECURITY
PORTSECURITY SWITCH Enable Flag eNodeB
PORTSECURITY
ADD PPPLNK
LST PPPLNK
DSP
PPPLNK CN Cabinet No. eNodeB PORTSECURITY
RMV PPPLNK
RST PPPLNK
LST PPPLNK
ADD PPPLNK
DSP PPPLNK
PPPLNK SRN Subrack No. eNodeB RMV PPPLNK
ADD PPPLNK
RST PPPLNK
DSP PPPLNK
LST PPPLNK
PPPLNK SN Slot No. eNodeB RMV PPPLNK
ADD PPPLNK
RST PPPLNK
DSP PPPLNK
LST PPPLNK
PPPLNK PPPLNKN PPP Link No. eNodeB RMV PPPLNK
RST PPPLNK
LST PPPLNK
ADD PPPLNK
PPPLNK PN Port No. eNodeB
LST PPPLNK
ADD PPPLNK
PPPLNK AUTH Authentication Type eNodeB
LST PPPLNK
ADD PPPLNK
PPPLNK UN User Name eNodeB
LST PPPLNK
ADD PPPLNK
PPPLNK PWD Password eNodeB
LST PPPLNK
ADD PPPLNK
PPPLNK TSN Time Slot No. eNodeB
LST PPPLNK
ADD PPPLNK
PPPLNK LOCALIP Local IP eNodeB DSP PPPLNK
LST PPPLNK
ADD PPPLNK
PPPLNK IPMASK Mask eNodeB DSP PPPLNK
LST PPPLNK
ADD PPPLNK
PPPLNK PEERIP Peer IP eNodeB DSP PPPLNK
LST PPPLNK
ADD PPPLNK
PPPLNK MUXCP PPPMUX eNodeB DSP PPPLNK
LST PPPLNK
Maximum Length of ADD PPPLNK
PPPLNK MAXSFLEN eNodeB
PPP Mux Subframe LST PPPLNK
Maximum Length of ADD PPPLNK
PPPLNK MAXMFLEN eNodeB
PPP Muxframe LST PPPLNK
PPP Muxframe
ADD PPPLNK
PPPLNK MUXTIME Combination eNodeB
LST PPPLNK
Timeout
ADD PPPLNK
IP Header
PPPLNK IPHC eNodeB DSP PPPLNK
Compression
LST PPPLNK
ADD PPPLNK
Maximum Receive
PPPLNK MRU eNodeB DSP PPPLNK
Unit
LST PPPLNK
ADD PPPLNK
Protocol Field
PPPLNK PFC eNodeB DSP PPPLNK
Compression
LST PPPLNK
Address and ADD PPPLNK
PPPLNK ACFC Control Field eNodeB DSP PPPLNK
Compression LST PPPLNK
ADD PPPLNK
PPPLNK RESTARTTMR Negotiation Time eNodeB
LST PPPLNK

PPPLNK PPPLinkStatus Link Status eNodeB DSP PPPLNK

PPPLNK LCPSTATUS LCP Status eNodeB DSP PPPLNK

PPPLNK IPCPSTATUS IPCP Status eNodeB DSP PPPLNK


PPPLNK PPPMUXSTATUS PPPMUX Status eNodeB DSP PPPLNK

Local IP Negotiation
PPPLNK LOCALIPNEGRLT eNodeB DSP PPPLNK
Result
Local IP Mask
PPPLNK MASKNEGRLT eNodeB DSP PPPLNK
Negotiation Result
Peer IP Negotiation
PPPLNK PEERIPNEGRLT eNodeB DSP PPPLNK
Result
IPHC Negotiation
PPPLNK IPHCNEGRLT eNodeB DSP PPPLNK
Result
ACFC Negotiation
PPPLNK ACFCNEGRLT eNodeB DSP PPPLNK
Result
PFC Negotiation
PPPLNK PFCNEGRLT eNodeB DSP PPPLNK
Result
Maximum Receive
PPPLNK MRUNEGRLT Unit Negotiation eNodeB DSP PPPLNK
Result
PPPMUX
PPPLNK MUXNEGRLT eNodeB DSP PPPLNK
Negotiation Result
Number of RX
PPPLNK RXPKT eNodeB DSP PPPLNK
Packets
Number of TX
PPPLNK TXPKT eNodeB DSP PPPLNK
Packets

PPPLNK RXFLOW RX Flow eNodeB DSP PPPLNK

PPPLNK TXFLOW TX Flow eNodeB DSP PPPLNK

PPPLNK IPNum Number of IPs eNodeB DSP PPPLNK

PPPLNK IPList IP Address List eNodeB DSP PPPLNK


PPP Fault Frame
ADD PPPLNK
PPPLNK FFAPHOLD Occurrence eNodeB
LST PPPLNK
Threshold
PPP Fault Frame ADD PPPLNK
PPPLNK FFDPHOLD eNodeB
Clear Threshold LST
ADDPPPLNK
PPPLNK
DSP PPPLNK
PPPLNK SBT Subboard Type eNodeB RMV PPPLNK
RST PPPLNK
Number of RX LST PPPLNK
PPPLNK RXBYTE eNodeB DSP PPPLNK
Bytes
Number of RX Drop
PPPLNK RXDROPPKT eNodeB DSP PPPLNK
Packets
Number of RX Drop
PPPLNK RXDROPBYTE eNodeB DSP PPPLNK
Bytes
Number of TX
PPPLNK TXBYTE eNodeB DSP PPPLNK
Bytes
Number of TX Drop
PPPLNK TXDROPPKT eNodeB DSP PPPLNK
Packets
Number of TX Drop
PPPLNK TXDROPBYTE eNodeB DSP PPPLNK
Bytes
SET PRI2QUE
PRI2QUE PRI0 PriOfQue0 eNodeB
LST PRI2QUE
SET PRI2QUE
PRI2QUE PRI1 PriOfQue1 eNodeB
LST PRI2QUE
SET PRI2QUE
PRI2QUE PRI2 PriOfQue2 eNodeB
LST PRI2QUE
SET PRI2QUE
PRI2QUE PRI3 PriOfQue3 eNodeB
LST PRI2QUE
SET PRI2QUE
PRI2QUE PRI4 PriOfQue4 eNodeB
LST PRI2QUE
SET PRI2QUE
PRI2QUE PRI5 PriOfQue5 eNodeB
LST PRI2QUE
SET PRI2QUE
PRI2QUE PRI6 PriOfQue6 eNodeB
LST
ADDPRI2QUE
RSCGRP
DSP RSCGRP
RSCGRP CN Cabinet No. eNodeB MOD RSCGRP
ADD
RMV RSCGRP
RSCGRP
DSP RSCGRP
LST RSCGRP
RSCGRP SRN Subrack No. eNodeB MOD RSCGRP
ADD
RMV RSCGRP
RSCGRP
DSP RSCGRP
LST RSCGRP
RSCGRP SN Slot No. eNodeB MOD RSCGRP
ADD
RMV RSCGRP
RSCGRP
Transmission DSP RSCGRP
LST RSCGRP
RSCGRP BEAR Resource Group eNodeB MOD RSCGRP
Bear Type ADD
RMV RSCGRP
RSCGRP
DSP RSCGRP
LST RSCGRP
RSCGRP SBT Subboard Type eNodeB MOD RSCGRP
ADD
RMV RSCGRP
RSCGRP
DSP RSCGRP
LST RSCGRP
RSCGRP PT Bearing Port Type eNodeB MOD RSCGRP
ADD
RMV RSCGRP
RSCGRP
DSP RSCGRP
LST RSCGRP
RSCGRP PN Bearing Port No. eNodeB MOD RSCGRP
ADD
RMV RSCGRP
RSCGRP
DSP RSCGRP
LST RSCGRP
Transmission
RSCGRP RSCGRPID eNodeB MOD RSCGRP
Resource Group ID
RMV RSCGRP
ADD RSCGRP
LST RSCGRP
MOD RSCGRP
RSCGRP RU Rate Unit eNodeB
DSP RSCGRP
ADD RSCGRP
LST RSCGRP
MOD RSCGRP
RSCGRP TXBW Tx Bandwidth eNodeB
DSP RSCGRP
ADD RSCGRP
LST RSCGRP
MOD RSCGRP
RSCGRP RXBW Rx Bandwidth eNodeB
DSP RSCGRP
LST
ADDRSCGRP
RSCGRP
TX Committed
RSCGRP TXCBS eNodeB MOD RSCGRP
Burst Size
LST RSCGRP
ADD RSCGRP
TX Excessive Burst
RSCGRP TXEBS eNodeB MOD RSCGRP
Size
LST RSCGRP
ADD RSCGRP
RSCGRP OID Operator ID eNodeB
LST RSCGRP
ADD RSCGRP
RSCGRP WEIGHT Scheduling Weight eNodeB MOD RSCGRP
LST RSCGRP
ADD RSCGRP
TX Commited
RSCGRP TXCIR eNodeB MOD RSCGRP
Information Rate
LST RSCGRP
ADD RSCGRP
RX Commited
RSCGRP RXCIR eNodeB MOD RSCGRP
Information Rate
LST RSCGRP
ADD RSCGRP
TX Peak
RSCGRP TXPIR eNodeB MOD RSCGRP
Information Rate
LST RSCGRP
ADD RSCGRP
RX Peak
RSCGRP RXPIR eNodeB MOD RSCGRP
Information Rate
LST RSCGRP
ADD RSCGRP
RSCGRP TXPBS TX Peak Burst Size eNodeB MOD RSCGRP
LST RSCGRP
Realtime TX
RSCGRP TxRTBw eNodeB DSP RSCGRP
Bandwidth
Realtime RX
RSCGRP RxRTBw eNodeB DSP RSCGRP
Bandwidth
Non-Realtime TX
RSCGRP TxNRTBw eNodeB DSP RSCGRP
Bandwidth
Non-Realtime RX
RSCGRP RxNRTBw eNodeB DSP RSCGRP
Bandwidth
Non-Realtime
RSCGRP TxNRTResvBw Reserved TX eNodeB DSP RSCGRP
Bandwidth
Non-Realtime
RSCGRP RxNRTResvBw Reserved RX eNodeB DSP RSCGRP
Bandwidth
RSCGRP TxGBRBwRlt GBR Tx Bandwidth eNodeB DSP RSCGRP

RSCGRP RxGBRBwRlt GBR Rx Bandwidth eNodeB DSP RSCGRP

Rate Configuration
RSCGRP RateCfgType eNodeB DSP RSCGRP
Type
UL Admin
RSCGRP ULAdminBw eNodeB DSP RSCGRP
Bandwidth
DL Admin
RSCGRP DLAdminBw eNodeB DSP RSCGRP
Bandwidth
UL CIR Admin
RSCGRP ULCirAdminBw eNodeB DSP RSCGRP
Bandwidth
DL CIR Admin
RSCGRP DLCirAdminBw eNodeB DSP RSCGRP
Bandwidth
UL PIR Admin
RSCGRP ULPirAdminBw eNodeB DSP RSCGRP
Bandwidth
DL PIR Admin
RSCGRP DLPirAdminBw eNodeB DSP RSCGRP
Bandwidth
SET RSCGRPALG
RSCGRPALG CN Cabinet No. eNodeB
LST RSCGRPALG
SET RSCGRPALG
RSCGRPALG SRN Subrack No. eNodeB
LST RSCGRPALG
SET RSCGRPALG
RSCGRPALG SN Slot No. eNodeB
LST RSCGRPALG
SET RSCGRPALG
RSCGRPALG SBT Subboard Type eNodeB
LST RSCGRPALG
SET RSCGRPALG
RSCGRPALG PT Bearing Port Type eNodeB
LST RSCGRPALG
SET RSCGRPALG
RSCGRPALG PN Bearing Port No. eNodeB
LST RSCGRPALG
Transmission SET RSCGRPALG
RSCGRPALG RSCGRPID eNodeB
Resource Group ID LST RSCGRPALG
TX Traffic Shaping SET RSCGRPALG
RSCGRPALG TXSSW eNodeB
Switch LST RSCGRPALG
TX Bandwidth SET RSCGRPALG
RSCGRPALG TXBWASW eNodeB
Adjustment Switch LST RSCGRPALG
RX Bandwidth SET RSCGRPALG
RSCGRPALG RXBWASW eNodeB
Adjustment Switch LST RSCGRPALG
Packet Loss Ratio SET RSCGRPALG
RSCGRPALG PLRDTH eNodeB
Down Threshold LST RSCGRPALG
Delay Down SET RSCGRPALG
RSCGRPALG DDTH eNodeB
Threshold LST RSCGRPALG
Traffic Control SET RSCGRPALG
RSCGRPALG TCSW eNodeB
Switch LST RSCGRPALG
OM/FTP Traffic SET RSCGRPALG
RSCGRPALG OMTCSW eNodeB
Control Switch LST RSCGRPALG
SET RSCGRPALG
RSCGRPALG PQN PQ Number eNodeB
LST RSCGRPALG
Congestion Time SET RSCGRPALG
RSCGRPALG CTTH eNodeB
Threshold LST RSCGRPALG
Congestion Clear SET RSCGRPALG
RSCGRPALG CCTTH eNodeB
Time Threshold LST RSCGRPALG
TX Reserved SET RSCGRPALG
RSCGRPALG TXRSVBW eNodeB
Bandwidth LST RSCGRPALG
RX Reserved SET RSCGRPALG
RSCGRPALG RXRSVBW eNodeB
Bandwidth LST RSCGRPALG
Drop Packet ADD SCTPLNK
SET RSCGRPALG
RSCGRPALG DROPPKTNUM eNodeB BLK SCTPLNK
Number Threshold LST RSCGRPALG
DSP SCTPLNK
LST SCTPLNK
SCTPLNK SCTPNO SCTP Link No. eNodeB
MOD SCTPLNK
RMV SCTPLNK
ADD SCTPLNK
SCTPLNK CN Cabinet No. eNodeB RST SCTPLNK
DSP SCTPLNK
UBL SCTPLNK
LST SCTPLNK
ADD SCTPLNK
SCTPLNK SRN Subrack No. eNodeB DSP SCTPLNK
LST SCTPLNK
ADD SCTPLNK
SCTPLNK SN Slot No. eNodeB DSP SCTPLNK
LST SCTPLNK
Maximum Stream ADD SCTPLNK
SCTPLNK MAXSTREAM eNodeB
No. LST SCTPLNK
ADD SCTPLNK
First Local IP MOD SCTPLNK
SCTPLNK LOCIP eNodeB
Address DSP SCTPLNK
LST SCTPLNK
ADD SCTPLNK
Second Local IP MOD SCTPLNK
SCTPLNK SECLOCIP eNodeB
Address DSP SCTPLNK
ADD SCTPLNK
LST SCTPLNK
Local SCTP Port MOD SCTPLNK
SCTPLNK LOCPORT eNodeB
No. DSP SCTPLNK
ADD SCTPLNK
LST SCTPLNK
First Peer IP MOD SCTPLNK
SCTPLNK PEERIP eNodeB
Address DSP SCTPLNK
ADD SCTPLNK
LST SCTPLNK
Second Peer IP MOD SCTPLNK
SCTPLNK SECPEERIP eNodeB
Address DSP SCTPLNK
ADD SCTPLNK
LST SCTPLNK
Peer SCTP Port MOD SCTPLNK
SCTPLNK PEERPORT eNodeB
No. DSP SCTPLNK
LST SCTPLNK
ADD SCTPLNK
SCTPLNK RTOMIN RTO Min Value eNodeB
LST SCTPLNK
ADD SCTPLNK
SCTPLNK RTOMAX RTO Max Value eNodeB
LST SCTPLNK
ADD SCTPLNK
SCTPLNK RTOINIT RTO Initial Value eNodeB
LST SCTPLNK
ADD SCTPLNK
SCTPLNK RTOALPHA RTO Alpha Value eNodeB
LST SCTPLNK
ADD SCTPLNK
SCTPLNK RTOBETA RTO Beta Value eNodeB
LST SCTPLNK
ADD SCTPLNK
SCTPLNK HBINTER Heart-beat Interval eNodeB MOD SCTPLNK
LST SCTPLNK
ADD SCTPLNK
Max Association
SCTPLNK MAXASSOCRETR eNodeB MOD SCTPLNK
Retransmission
LST SCTPLNK
ADD SCTPLNK
Max Path
SCTPLNK MAXPATHRETR eNodeB MOD SCTPLNK
Retransmission
LST SCTPLNK
Send Message ADD SCTPLNK
SCTPLNK CHKSUMTX eNodeB
Checksum Flag LST SCTPLNK
Receive Message ADD SCTPLNK
SCTPLNK CHKSUMRX eNodeB
Checksum Flag LST SCTPLNK
Checksum ADD SCTPLNK
SCTPLNK CHKSUMTYPE eNodeB
Arithmetic Type LST SCTPLNK
ADD SCTPLNK
SCTPLNK AUTOSWITCH Switch Back Flag eNodeB MOD SCTPLNK
LST SCTPLNK
ADD SCTPLNK
SWITCHBACKHBN Heart-beat Times
SCTPLNK eNodeB MOD SCTPLNK
UM When Switch Back
LST SCTPLNK
SCTPLNK AssocState SCTP Link Status eNodeB DSP SCTPLNK

Status Change
SCTPLNK TransferCause eNodeB DSP SCTPLNK
Cause
Status Change
SCTPLNK TransferTime eNodeB DSP SCTPLNK
Time

SCTPLNK OUTSTREAM Out Stream Number eNodeB DSP SCTPLNK

SCTPLNK INSTREAM In Stream Number eNodeB DSP SCTPLNK


SCTPLNK WORKADDRFLAG Work Address Flag eNodeB DSP SCTPLNK

DSP SCTPLNK
SCTPLNK BLKFLAG Block Flag eNodeB
LST SCTPLNK
ADD SCTPLNK
SCTPLNK TSACK SACK Timeout eNodeB
LST SCTPLNK
ADD SCTPLNK
SCTPLNK DESCRI Description Info eNodeB MOD SCTPLNK
Resource Group LST SCTPLNK
RSCGRPULCACS Uplink Admission SET TACALG
TACALG eNodeB
WITCH Control Algorithm LST TACALG
Resource
Switch Group
RSCGRPDLCACS Downlink Admission SET TACALG
TACALG eNodeB
WITCH Control Algorithm LST TACALG
Switch
USERDATATYPE1 User Data Type 1 SET TACALG
TACALG eNodeB
ACTFACTOR Act Factor LST TACALG
USERDATATYPE2 User Data Type 2 SET TACALG
TACALG eNodeB
ACTFACTOR Act Factor LST TACALG
USERDATATYPE3 User Data Type 3 SET TACALG
TACALG eNodeB
ACTFACTOR Act Factor LST TACALG
USERDATATYPE4 User Data Type 4 SET TACALG
TACALG eNodeB
ACTFACTOR Act Factor LST TACALG
USERDATATYPE5 User Data Type 5
TACALG eNodeB LST TACALG
ACTFACTOR Act Factor
USERDATATYPE6 User Data Type 6 SET TACALG
TACALG eNodeB
ACTFACTOR Act Factor LST TACALG
USERDATATYPE7 User Data Type 7 SET TACALG
TACALG eNodeB
ACTFACTOR Act Factor LST TACALG
USERDATATYPE8 User Data Type 8 SET TACALG
TACALG eNodeB
ACTFACTOR Act Factor LST TACALG
USERDATATYPE9 User Data Type 9 SET TACALG
TACALG eNodeB
ACTFACTOR Act Factor LST TACALG
Uplink Handover
SET TACALG
TACALG TRMULHOCACTH Service Admission eNodeB
LST TACALG
Threshold
Downlink Handover
SET TACALG
TACALG TRMDLHOCACTH Service Admission eNodeB
LST TACALG
Threshold
Uplink Golden New
TRMULGOLDCAC SET TACALG
TACALG Service Admission eNodeB
TH LST TACALG
Threshold
Downlink Golden
TRMDLGOLDCAC New Service SET TACALG
TACALG eNodeB
TH Admission LST TACALG
Threshold
Uplink Silver New
TRMULSILVERCA SET TACALG
TACALG Service Admission eNodeB
CTH LST TACALG
Threshold
Downlink Silver
TRMDLSILVERCA New Service SET TACALG
TACALG eNodeB
CTH Admission LST TACALG
Threshold
Uplink Bronze New
TRMULBRONZEC SET TACALG
TACALG Service Admission eNodeB
ACTH LST TACALG
Threshold
Downlink Bronze
TRMDLBRONZEC New Service SET TACALG
TACALG eNodeB
ACTH Admission LST TACALG
Threshold
Uplink GBR Service
TRMULGBRCACT SET TACALG
TACALG Admission eNodeB
H LST TACALG
Threshold
Downlink GBR
TRMDLGBRCACT SET TACALG
TACALG Service Admission eNodeB
H LST TACALG
Threshold
Uplink Pre-emption SET TACALG
TACALG TRMULPRESW eNodeB
Algorithm Switch LST TACALG
Downlink Pre-
SET TACALG
TACALG TRMDLPRESW emption Algorithm eNodeB
LST TACALG
Switch
Physical Port Up
SET TACALG
TACALG PORTULOBSW Link OverBooking eNodeB
LST TACALG
Switch
Physical Port Down
SET TACALG
TACALG PORTDLOBSW Link OverBooking eNodeB
LST TACALG
Switch
Physical Port Up
SET TACALG
TACALG PORTULCACSW Link Admission eNodeB
LST TACALG
Switch
Physical Port Down
SET TACALG
TACALG PORTDLCACSW Link Admission eNodeB
LST TACALG
Switch
USERDATATYPE5 User Data Type 5 SET TACALG
TACALG eNodeB
FLOWCTRLTYPE Flow Control Type LST TACALG
USERDATATYPE6 User Data Type 6 SET TACALG
TACALG eNodeB
FLOWCTRLTYPE Flow Control Type LST TACALG
USERDATATYPE7 User Data Type 7 SET TACALG
TACALG eNodeB
FLOWCTRLTYPE Flow Control Type LST TACALG
USERDATATYPE8 User Data Type 8 SET TACALG
TACALG eNodeB
FLOWCTRLTYPE Flow Control Type LST TACALG
USERDATATYPE9 User Data Type 9 SET TACALG
TACALG eNodeB
FLOWCTRLTYPE Flow Control Type LST TACALG
Uplink High Load SET TLDRALG
TLDRALG TRMULLDRTRGTH eNodeB
Trigger Threshold LST TLDRALG
Downlink High Load SET TLDRALG
TLDRALG TRMDLLDRTRGTH eNodeB
Trigger Threshold LST TLDRALG
Uplink High Load SET TLDRALG
TLDRALG TRMULLDRCLRTH eNodeB
Clear Threshold LST TLDRALG
Downlink High Load SET TLDRALG
TLDRALG TRMDLLDRCLRTH eNodeB
Clear Threshold LST TLDRALG
Uplink Medium
TRMULMLDTRGT SET TLDRALG
TLDRALG Load Trigger eNodeB
H LST TLDRALG
Threshold
Downlink Medium
TRMDLMLDTRGT SET TLDRALG
TLDRALG Load Trigger eNodeB
H LST TLDRALG
Threshold
Uplink Medium
SET TLDRALG
TLDRALG TRMULMLDCLRTH Load Clear eNodeB
LST TLDRALG
Threshold
Downlink Medium
SET TLDRALG
TLDRALG TRMDLMLDCLRTH Load Clear eNodeB
LST TLDRALG
Threshold
TRMULOLCSWITC Uplink OLC SET TOLCALG
TOLCALG eNodeB
H Arithmetic Switch LST TOLCALG
TRMDLOLCSWITC Downlink OLC SET TOLCALG
TOLCALG eNodeB
H Arithmetic Switch LST TOLCALG
TRMULOLCTRIGT Uplink OLC Trigger SET TOLCALG
TOLCALG eNodeB
H Threshold LST TOLCALG
Uplink OLC SET TOLCALG
TOLCALG TRMULOLCRELTH eNodeB
Release Threshold LST TOLCALG
TRMOLCRELBEAR OLC Release SET TOLCALG
TOLCALG eNodeB
ERNUM Bearer No. LST TOLCALG
TRMDLOLCTRIGT Downlink OLC SET TOLCALG
TOLCALG eNodeB
H Trigger Threshold LST TOLCALG
Downlink OLC SET TOLCALG
TOLCALG TRMDLOLCRELTH eNodeB
Release Threshold LST TOLCALG
SET
PINGFILTERMODE
TRANSPORT MODE Ping Filter Mode eNodeB
LST
ADD VLANCLASS
PINGFILTERMODE
LST VLANCLASS
VLANCLASS VLANGROUPNO VLAN Group No. eNodeB
MOD VLANCLASS
ADD
RMV VLANCLASS
VLANCLASS
MOD VLANCLASS
VLANCLASS TRAFFIC Traffic Type eNodeB
RMV VLANCLASS
ADD VLANCLASS
LST VLANCLASS
User Data Service MOD VLANCLASS
VLANCLASS SRVPRIO eNodeB
Priority RMV VLANCLASS
LST
ADDVLANCLASS
VLANCLASS
VLANCLASS VLANID VLAN ID eNodeB MOD VLANCLASS
LST VLANCLASS
ADD VLANCLASS
VLANCLASS VLANPRIO VLAN Priority eNodeB MOD VLANCLASS
LST VLANCLASS
ADD VLANMAP
MOD VLANMAP
VLANMAP NEXTHOPIP Next Hop IP eNodeB
RMV VLANMAP
ADD VLANMAP
LST VLANMAP
MOD VLANMAP
VLANMAP MASK Mask eNodeB
RMV VLANMAP
LST
ADDVLANMAP
VLANMAP
VLANMAP VLANMODE VLAN Mode eNodeB MOD VLANMAP
LST VLANMAP
ADD VLANMAP
VLANMAP VLANID VLAN ID eNodeB MOD VLANMAP
LST VLANMAP
ADD VLANMAP
VLANMAP VLANPRIO VLAN Priority eNodeB MOD VLANMAP
LST VLANMAP
ADD VLANMAP
VLANMAP VLANGROUPNO VLAN Group No. eNodeB MOD VLANMAP
LST VLANMAP
ADD VLANMAP
VLANMAP SETPRIO Set VLAN Priority eNodeB MOD VLANMAP
LST VLANMAP
Meaning IsKey Mandatory Dynamic Attribute Feature ID

Indicates the device


YES YES No LOFD-001024
number of the ALD.
Indicates the
vendor code of the
NO NO Yes LOFD-001024
device
Indicatesin the
the serial
device
Indicates
scanning the
result.
name of
number of the ALD,
the
which NO NO Yes LOFD-001024
deviceisinoptional
the
but must be
scanning unique.
result.
The device name
NO NO No LOFD-001024
identifies the ALD.
Indicates
The format the
of the
cabinet
name is number of
NO NO No LOFD-001024
the RRU that
site_sector_device
Indicates
controls theALD.
the
type_network
subrack number type.
of
NO YES No LOFD-001024
the RRU that
Indicates
controls the theALD. slot
number of the RRU
Indicates the the actual NO YES No LOFD-001024
that controls
protocol
ALD. version of
the ALD. You can
NO NO Yes LOFD-001024
run the SCN ALD
command
Indicates the to query
total
the parameter.
number of ALD NO NO Yes LOFD-001024
subunits.
Indicates the
version information
NO NO Yes LOFD-001024
about the ALD
Indicates
hardware.the
version information
NO NO Yes LOFD-001024
about the ALD
Indicates
software. the
Indicates the
connection device
scenario NO NO Yes LOFD-001024
model
of of the ALD.
the RET
antenna. This
Indicates
parameterthe must devicebe NO NO Yes LOFD-001024
type of the
set in accordance ALD.
Indicates
with physical the
vendor code
connections.
Indicates the of In the NO YES No LOFD-001024
ALD.
daisy chain
number of subunits
Indicates
configuredthe
scenarios, forserial
the the NO YES No LOFD-001024
number
correct
Indicates
RET of
vendor
antenna. the
the RET ALD.
Ifcode
this
and
antennadevice
parameter type,isserial
which
number
can be must
changed, subunits be NO YES No LOFD-001024
Indicates
set. The value
SINGLE_RET
are added the
or or of
polarization
this parameter
MULTI_RET.
removed in type mustof
the
be RET antenna,
consistent
ascending or with NO YES No LOFD-001024
which can beorder
the actual
descending
SINGLE
connection
by subunit ornumber.
DUAL.
NO YES No LOFD-001024
scenario.
The number of RET
Otherwise,
subunits that thecan
eNodeB
be configuredtofor an
fails NO NO No LOFD-001024
communicate
RET antenna varies with
the ALD.
depending If
Indicates the devicethe
on the
vendor code YES YES No LOFD-001024
RET antenna
number of theor the
type.
ALD.
device
Indicates serialthe
A maximum of eight
number
vendor is notofcan
code
RET subunits the
NO NO Yes LOFD-001024
specified,
device
be in the
configured the for an
Indicates
system the
returns serial
scanning
RET antenna result. ofathe
number
message ofindicating
the
MULTI_RET type. NO NO Yes LOFD-001024
device
that inparameter
the
The thenumber of RET
scanning
is invalid.for result.
To an query
subunits RET
the vendor
antenna of code
the
and device serial
SINGLE_RET type
number, run the
is 1 by default.
SCN ALD
command.
Indicates the device
name of the ALD,
which is optional
but must be unique.
The device name
NO NO No LOFD-001024
identifies the ALD.
Indicates the
The format of the
cabinet
name isnumber of NO NO No LOFD-001024
the RRU that
site_sector_device
Indicates
controls theALD.
the
type_network
subrack number type.
of
NO YES No LOFD-001024
the RRU that
Indicates the slot
controls the ALD.
number of the RRU
Indicates actual NO
the the
that controls
YES No LOFD-001024
protocol
ALD. version of
the ALD. You can
NO NO Yes LOFD-001024
run the SCN ALD
command to query
Indicates the total
the parameter.
number of ALD NO NO Yes LOFD-001024
subunits.
Indicates the
version information
NO NO Yes LOFD-001024
about the ALD
Indicates
hardware. the
version information
NO NO Yes LOFD-001024
about the ALD
software.
Indicates the device
NO NO Yes LOFD-001024
model of the ALD.
Indicates the device
NO NO Yes LOFD-001024
type of the ALD.
Indicates the device
YES YES No LOFD-001024
number of the RET.
Indicates the
number of the RET YES YES No LOFD-001024
subunit.
Indicates the
NO NO No LOFD-001024
antenna azimuth.
Indicates the model
of the RET antenna NO NO No LOFD-001024
Indicates
module. the
beamwidth
Indicates the ofbase
band
1. Beamwidth NO NO No LOFD-001024
station
Indicates ID.the
defines the
beamwidth
capability ofofanband
2. Beamwidth NO NO No LOFD-001024
antenna
Indicates tothetransmit
defines
RF the
signals. It also
beamwidth
capability ofofanband
defines the
3. Beamwidth width of NO NO No LOFD-001024
antenna
the antenna
Indicates tothetransmit
Indicates
defines thethe
RF signals. of
pattern.
beamwidth It also
band
antenna
capability gain of
ofwidth
an
defines
4. the
Beamwidth of NO NO No LOFD-001024
band
antenna 1. Antenna
to transmit
the antenna
Indicates
defines the
the It also
gain
RF is defined
signals. as
pattern.
antenna
capability gain
of anofan
the intensity of
defines the width of NO NO No LOFD-001024
band
antenna
antenna 2. Antenna
to atransmit
inthe given
the antenna
Indicates
gain
RF is defined
signals.
direction to as
It also
the
pattern.
antenna gainofofan
the intensity
defines
intensity the width
that would of NO NO No LOFD-001024
band 3. Antenna
antenna inthe
a given
theproduced
be antenna
Indicates by a
gain is defined
direction to the as
pattern. gain
hypothetical
antenna ideal
ofan
the intensity
intensity of
that would NO NO No LOFD-001024
antenna
band
antenna that
4. Antenna
in a given
be produced
radiates
gain equally
is defined byasain
direction
hypothetical to theideal
all
the directions
intensity
intensity thatof an
would NO NO No LOFD-001024
antenna
antenna that
(isotropically) and
in a given
be produced
radiates equally by ain
has no losses.
direction
hypothetical to theideal
all directions
intensity that would NO NO No LOFD-001024
antenna that
(isotropically) and
be produced
radiates equally by ain
has no losses.
hypothetical ideal
all directions
antenna that and
(isotropically)
radiates
has no losses. in
equally
all directions
(isotropically) and
has no losses.
Indicates the
installation date in
NO NO No LOFD-001024
the format of
YYYYMM.
Indicates the
mechanical tilt of NO NO No LOFD-001024
the installed RET.
Indicates the ID of
NO NO No LOFD-001024
the installer.
Indicates supported
NO NO No LOFD-001024
band 1.
Indicates supported
NO NO No LOFD-001024
band 2.
Indicates supported
NO NO No LOFD-001024
band 3.
Indicates the type
Indicates
of the ALDsupportedcurrent NO NO No LOFD-001024
band 4.
alarm threshold.
When
Indicates
ALDPwrSwitch the sectoris NO NO No LOFD-001024
ID.
set to ON, the
current
Indicates alarm
the serial
threshold NO NO No LOFD-001024
number ofofthe the port
ALD.
Indicates
should bethe specified.
maximumALD
Different tilt
NO NO Yes LOFD-001024
supported
system typesby the
Indicates
RET subunit.
should betheselected
minimum
accordingtilt to NO NO Yes LOFD-001024
supported
different ALD by types
the
Indicates
RET subunit. the
and connection
cabinet number of
methods. They the are YES YES No LOFD-001024
the RRU where
Indicates
described the
as
RET port is located.
subrack number of
follows:
YES YES No LOFD-001024
the RRU
For where the
RET (multi-wire
Indicates
RET port
cable mode) thelocated.
is slot
only:
number of
undercurrent alarm the RRU
YES YES No LOFD-001024
where
occur threshold:port
the RET 10
is
mA; located.
Indicates the
undercurrent
number
alarm clear of the RET YES YES No LOFD-001024
port on the15
threshold: RRU.mA;
Indicates
overcurrent thealarm
state
of the threshold:
ALD power NO NO No LOFD-001024
occur
supply
150 mA; switch.
Indicates
When an the
ALD
overcurrent
overcurrent alarm
alarm NO NO No LOFD-001024
needs
clear power
threshold: 120
clear
Indicates
supply, threshold.
set thethe ALD
mA.
When the ALD
overcurrent
power supply alarm
switch NO NO No LOFD-001024
If the previously
current value is less
generating
to ON.
listed
Indicates
than this threshold
the
threshold,
threshold. When
cannot
undercurrent
the ALD meet
overcurrent the
alarm
the current NO NO No LOFD-001024
requirements,
clear
alarm threshold.
is cleared. you
value
Indicates is greater
the
can
When choose to
thethreshold,
ALD
than this
undercurrent
customize
current value thealarm
is NO NO No LOFD-001024
an overcurrent
generating
threshold
greater thanaccording
this
alarm
threshold. is reported.
When
to the actual
threshold, thedevice
the
type. ALD The current
undercurrent alarm NO NO No LOFD-001024
Indicates
value
customized the actual
is smaller
is cleared.
Indicates the
state
than
threshold of the ALD
this threshold,
should
observed
meet the followingof
power
an supply
undercurrent current NO NO Yes LOFD-001024
the
alarm ALD.
switch. isWhen
requirements: reported. an
overcurrent
Undercurrentoralarm NO NO Yes LOFD-001024
undercurrent
occur threshold alarm
<
is reported,
Undercurrent alarm the
actual state may<
clear threshold
differ from
Overcurrent thealarm
configured
clear threshold state. <
Overcurrent alarm
occur threshold
Indicates the device
YES YES No LOFD-001024
number of the RET.
Indicates the
number of the RET YES YES No LOFD-001024
subunit.
Indicates the online
status of the NO NO Yes LOFD-001024
subunit.
Indicates the actual
tilt of the RET NO NO Yes LOFD-001024
subunit.
Indicates the sector
Indicates
Indicates
ID of the RET the
the NO NO Yes LOFD-001024
cabinet
subunit. numberof
subrack number of
the RRU
the RRU to to which
which
the antenna port is 1 NO NO No LOFD-001024
connected
of the ALD to is
through
connected.
Indicates antenna
theWhen
slot
port 1. NO NO No LOFD-001024
the subrack
number of the number
RRU
of
to the
whichport theto which
Indicates
the
antennaRET is the portis
subunit NO NO No LOFD-001024
Indicates
number
connected ofthe
the RRU
is 255,
connected
Indicates to
the
subrack
to
thewhich
port isnumber
thenot of
through
cabinet antenna
the
antennaRRUnumberto which of
1. is
connected.
port
the RRU to which
NO NO No LOFD-001024
the antennatoport 2
connected
the
of antenna
the
through ALD isis
antenna
connected
connected.
port 1. through
This NO NO No LOFD-001024
Indicates
the antenna
parameter the slot 2.
isport
valid
number
for the dual- RRU
This of
parameter the is
to
validwhich
to the
the dual- NO NO No LOFD-001024
polarized
Indicatesisthe antenna.
port
antenna
polarized
When the antenna.
subrack
number
connected of the RRU
through
number
to which of
thethe port NO NO No LOFD-001024
antenna
to which portthe RET 2. This
antenna
parameter is is valid
subunit
connected is through
when
connected a dual- is 255, NO NO No LOFD-001024
antenna port
polarized 2. This
the port isantenna
parameter not
Indicates
is used. the valid
is
connected.
Indicates
when a dual-theofalarm
antenna tilt the NO NO No LOFD-001024
error
polarized
RET range
subunit. of the
antenna
tilt of the RET
is used.
subunit. When the NO NO No LOFD-001024
tilt error reaches
Indicates the the
threshold,
number of the alarm
is reported.TMA NO YES No LOFD-001024
configured
subunits.
Indicates the device
YES YES No LOFD-001024
number of the ALD.
Indicates the
vendor code of the
NO NO Yes LOFD-001024
device
Indicates in the
the device
Indicates
scanning the serial
result.
name of
number of the the ALD,
which NO NO Yes LOFD-001024
deviceisinoptional
the
but must be
scanning unique.
result.
The device name
NO NO No LOFD-001024
identifies the ALD.
Indicates
The format the of the
cabinet
name is number of
NO NO No LOFD-001024
the RRU that
site_sector_device
Indicates
controls thetheALD.
type_network
subrack number type.
of
NO YES No LOFD-001024
the RRU that
Indicates the slot
controls the ALD.
number of the RRU
NO YES No LOFD-001024
that controls the
ALD.
Indicates the actual
protocol version of
the ALD. You can
NO NO Yes LOFD-001024
run the SCN ALD
command to query
Indicates the total
the parameter.
number of ALD NO NO Yes LOFD-001024
subunits.
Indicates the
version information
NO NO Yes LOFD-001024
about the ALD
Indicates
hardware.the
version information
NO NO Yes LOFD-001024
about the ALD
software.
Indicates the device
NO NO Yes LOFD-001024
model of the ALD.
Indicates the device
NO NO Yes LOFD-001024
type of the ALD.
Indicates the device
YES YES No LOFD-001024
number of the TMA.
Indicates the
number of the TMA YES YES No LOFD-001024
subunit.
Indicates the
NO NO No LOFD-001024
antenna
Indicatesazimuth.
the
beamwidth
Indicates the ofbase
band
1. Beamwidth NO NO No LOFD-001024
station
Indicates ID.the
defines the
beamwidth
capability ofofanband
2. Beamwidth NO NO No LOFD-001024
antenna
Indicates tothetransmit
defines
RF the
signals. It also
beamwidth
capability ofofanband
defines
3. the
Beamwidth width of NO NO No LOFD-001024
antenna
the antenna
Indicates tothetransmit
Indicates
defines thethe
RF signals.
pattern.
beamwidth It also
antenna
capability
defines the ofof
gain anband
of
width of
4.
bandBeamwidth
1. Antenna NO NO No LOFD-001024
antenna
the antennato transmit
Indicates
defines
gain thethe
is defined as
RF signals.
pattern. It also
antenna
capability gainan ofofanof
the theofwidth
intensity
defines NO NO No LOFD-001024
band
antenna
antenna 2. Antenna
to atransmit
inthe given
the antenna
Indicates
gain
RF is defined
signals.
direction to as
It also
the
pattern.
antenna gain ofan
the intensity
defines the
intensity of
thatwidth
would of NO NO No LOFD-001024
band
antenna 3. Antenna
inthe
a given
the
be antenna
produced
Indicates by a
gain is defined
direction to the as
pattern.
hypothetical
antenna gain ideal
ofan
the intensity
intensity of
that would NO NO No LOFD-001024
antenna
band
antenna that
4. Antenna
in a given
be produced
radiates
gain is equally
defined byasain
direction
hypothetical to theideal
all
the directions
intensity
intensity thatof an
would NO NO No LOFD-001024
antenna
antenna that
(isotropically)
in a and
given
be produced
radiates equally by ain
has no losses.
direction
hypothetical to theideal
all directions
intensity that would NO NO No LOFD-001024
antenna that
(isotropically) and
be produced
radiates equally by ain
has no losses.
hypothetical ideal
Indicates
all directionsthe
antenna that NO NO No LOFD-001024
installation
(isotropically) date.
and
radiates equally
has no losses.
Indicates the in
all directions
mechanical tilt of NO NO No LOFD-001024
(isotropically)
the installation. and
has no losses.
Indicates the ID of
NO NO No LOFD-001024
the installer.
Indicates supported
NO NO No LOFD-001024
band 1.
Indicates supported
NO NO No LOFD-001024
band 2.
Indicates supported
NO NO No LOFD-001024
band 3.
Indicates supported
NO NO No LOFD-001024
band 4.
Indicates the sector
NO NO No LOFD-001024
ID.
Indicates the serial
NO NO No LOFD-001024
number of the TMA.
Indicates the model
of the RET antenna
NO NO No LOFD-001024
connected to the
TMA.
Indicates
Indicates the
the gain
type NO NO No LOFD-001024
resolution.
of the TMA subunit.
It indicates whether
the VSWR NO NO No LOFD-001024
Indicates
measurement the and
maximum
the bypassRX mode
frequency
are supported. NO NO No LOFD-001024
bandwidth
Indicates the of the
subunit.
maximum transmit
NO NO No LOFD-001024
frequencythe
Indicates band of
the subunit.
minimum RX
frequency NO NO No LOFD-001024
Indicates
bandwidththe of the
minimum
subunit. TX
frequency NO NO No LOFD-001024
bandwidth of the
Indicates
subunit. the
maximum NO NO Yes LOFD-001024
supported gain.
Indicates the
minimum supported NO NO Yes LOFD-001024
gain.
Indicates the device
YES YES No LOFD-001024
number of the TMA.
Indicates the
number of the TMA YES YES No LOFD-001024
subunit.
Indicates the sector
ID of the TMA NO NO Yes LOFD-001024
subunit.
Indicates the actual
gain of the TMA NO NO Yes LOFD-001024
subunit.
Indicates the actual
working mode of NO NO Yes LOFD-001024
the TMA subunit.
Indicates the online
status of the
Indicates the TMA NO NO Yes LOFD-001024
subunit. of the
number
antenna port to
Indicates NO YES No LOFD-001024
which the theTMA
cabinet
subunit number
is of
the RRU
connected. or RFU of
Indicates theport
slot to NO YES No LOFD-001024
the antenna
number
which the ofsubunit
the RRU is
or RFU that
connected.
Indicates the port to NO YES No LOFD-001024
provides the
subrack
which the subunitofis
number
the RRU or RFU of
connected. NO YES No LOFD-001024
the antenna port to
which the subunit is
connected.
Indicates the gain
NO NO No LOFD-001024
of the TMA subunit.
Indicates the
working mode of NO NO No LOFD-001024
the TMA subunit.
Indicates the
cabinet number of
YES NO No None
the baseband
Indicates
processing the duplex
board.
subrack
mode in number
which the of
YES NO No None
the baseband
LBBP operates.
Indicates
The valuethe
processing
Indicates theboard.
slot
administrative
number of the state
TDD_ENHANCE YES YES No None
of the board.
indicates
LBBP. the The
time
administrative
division duplexstate
of the board
(TDD) mode can be NO NO No None
blocked,
Indicatesunblocked,
integrated with the
the
or shutting
beamforming
physical down.
(BF)
operation
For details, NO YES No None
function.
status thesee
of The BF
board,
ITU-T
which X.731.
function
Indicates canprovides
the
be
the data
operational
physical type
Uninstalled, state of
of the NO NO Yes None
Indicates
transmission
the
LBBP. board, the alarm
which
Starting up, Normal,
status.
service
can be For
in to
set
Inconsistent, details
about the
transmission
Enabled
Unconfigured, definition
or mode NO NO Yes LBFD-004006
of
7 Alarm
or
Disabled.
Power Status,
8 defined
off, Enabled
Fault,in the
see ITU-T
protocol.
indicates
Communication ForX.731.
that
Indicates the3GPP
E-the NO NO Yes None
details,
services see
lost, In test,can orbe
label, a on
TS 36.213.
carried
combination textthefile
of with
a maximum
board.
various Disabled
states.of 2For NO NO Yes LBFD-004012
KB. It
indicatesis used
that
example, if a board to
no
record
service the
can
is not configured be
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates such
the type
the main control as
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
physical
the bar
module.
operation
code of the status
boardof NO NO Yes None
Indicates the
the
or board
the isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.the board
by the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature of the NO NO Yes None
power amplifier.
Band2:
[9612-9888] Common Offset:
Frequencies
0 Special
Channel Number:
Frequencies
[9662-9938]
Channel Number: Offset:
0 Special
none Offset: 0
Frequencies
Band2: Common
Indicates
Channel Number:the
Frequencies
service type of the
(412,
Channel
Indicates437, 462,
Number:
the result
CPU
487, or DSP of the NO NO Yes None
of the512,
[9262-9538]
board.
537,
operation.
The
562,
Offset:
service
587,
0 612, 637, 662,
Special
types
687) of the DSP
Offset: 1850.1
Frequencies
consist
Band3: of
Channel
uplink
Common
Number:
NO NO Yes None
and downlink
Frequencies
(12, 37, 62,
services. The 87, 112,
Indicates
Channel
137, 162, the
Number:
187, type
service
of the typesOffset:
device.
[1162-1513] of212,
the NO NO Yes None
237,
CPU 262,
consist 287) of
1575
Offset:
IndicatesSpecial
1850.1
theSlave.
Office
Master
Frequencies and NO NO Yes None
Band3:
name ofCommon the BS.
Channel Number:
Frequencies
Indicates
none the 0
Offset:
Channel
software Number:
version of NO NO Yes None
Band4:
[937-1288] Common Offset:
the board.
Frequencies
1525
IndicatesSpecial
the
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Number:Offset:
Indicates
1805
none Special the 0
Offset:
BootROM
Frequencies
Band4: Common version NO NO Yes None
of the
Channel board.
Frequencies Number:
(1887,
Indicates
Channel 1912,
the 1937,
Number: test
1962, NO NO Yes None
time. 1987, 2012,
[1312-1513] Offset:
2037, 2062, 2087)
1450 Special
Indicates
Offset:
Frequencies the test
1735.1 NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762,Number:1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Indicates the
Channel
Frequencies
cabinet number Number: of
(1007,
Channel
the main 1012,
Number:
control 1032, YES NO No None
1037,
Indicates 1062,
[4132-4233]
and the1087)
transmission Offset:
Offset:
subrack
0 Special
board. 670.1
number of
Band6:
the main
Frequencies Common
control YES NO No None
Frequencies
and transmission
Channel
Indicates Number:
the
Indicates
Channel
board. the slot
Number:
(782,
physical 787, 807,
operation
number of the
[4387-4413] YES YES No None
812,
status
LMPT.
837,of the Offset:
862) board,
Indicates
0 Special
Offset:can
Indicates whether
670.1
the
which be
the LMPT
Frequencies
Band6:
operational instate
Common use is of
Uninstalled, NO NO Yes LBFD-00202101
the active
Channel
Indicates
Frequencies
the board, or
Number:
the alarm
Starting up,which
Normal,
standby
(1037,be 1062)
status.
Channel
can Forone.
set Offset:
details
Number:
to
Inconsistent,
670.1
about
Enabled Band7:
the
[4162-4188]
Unconfigured, or definition
Offset: NO NO Yes LBFD-004006
Common
of Alarm
0 Special
Disabled.
Power Status,
off, Enabled
Fault,
Frequencies
see ITU-T
Frequencies
indicates
Communication X.731.
that
Indicates
Channel theorbe
Number: E-the NO NO Yes None
services
lost, In test,can
[2237-2563]
label,
combination of with
(812,
carried a text
837)
on Offset:
file
Offset:
the
2175
a
board.
various Special
maximum
670.1 Band7:
Disabled
states. of 2For NO NO Yes LBFD-004012
Frequencies
KB.
CommonIt
indicates
example, is used
that to
no
if a board
Channel
record
Frequencies
service
is the Number:
can be
not configured
(2587,
Channel
carried
and fails 2612,
manufacturing the2637,
Number:
onto NO NO Yes None
2662, 2687,
information
[2012-2338]
board.
communicate 2712,
about
Offset:
with
2737,
equipment
2100
Indicates 2762,
Special
the
the main control 2787,
suchtype as
2812,
the 2837,
board,
Frequencies sub-2862, NO NO Yes None
of
andthe board.
transmission
2887,
board,2912)
board,
Channel or
the optical
Number:Offset:
physical
Indicates the bar
2105.1
module.
(2362,
operation Band8:
2387, status2412, of
code
Indicatesof the
the board NO NO Yes None
Common
2437,
thethe
board2462, 2487,
isabout
or cabinet.
description
Frequencies
2512, 2537, 2562,
Unconfigured,
the services
Channel Number:and
2587, 2612,
Communication 2637, NO NO Yes None
functions
[2937-3088] provided
Offset:
2662,
Indicates
lost. 2687)theOffset:
by
340 the board
Special or the
2030.1 Band8:
manufacturing date
cabinet.
Frequencies NO NO Yes None
Common
of the board or the
Channel
Frequencies
cabinet. Number:
none Offset:
Channel Number: 0
Band9: Common
[2712-2863] Offset:
Frequencies
340 Special
Channel Number:
Frequencies
[9237-9387]
Channel Number: Offset:
0 Special
none Offset: 0
Frequencies
The downlink and
uplink frequencies
of the local cell
must stay within the
same frequency
band.
The downlink and
Indicates
Frequency(MHZ)the
uplink frequencies=
manufacturer
(Frequency of the
of the local cell NO NO Yes None
board
Channel or the
must stayNumber
within the /
cabinet.
Indicates
5) + Offset the issue
Band1:
same frequency
number
band. of the
Common NO NO Yes None
board.
Frequencies
Frequency(MHZ) =
IndicatesNumber:
Channel
(Frequency the type
NO NO Yes None
of a board.
[10562-10838]
Channel Number /
Offset: 0 Special
5) + Offset Band1:
Indicates
Frequencies the object
Common NO NO Yes None
number
Channel of a board.
IndicatesNumber:
Frequencies the object
none
type ofOffset:
Channel a Number:
board,0
Band2:
[9612-9888]Common Offset: NO NO Yes None
which is CPU or
Frequencies
0 Special the
DSP.
Indicates
Channel
Frequencies Number:
temperature of a NO NO Yes None
[9662-9938]
Channel Offset:
board. Number:
0 Special
none Offset:
Indicates the 0
Frequencies
Band2:
temperatureCommon NO NO Yes None
Indicates
Channel theof the
Number:
Frequencies
power
service amplifier.
type of the
(412,
Channel437,
Indicates 462,
Number:
the result
CPU
487, or
512, DSP 537,of the
562, NO NO Yes None
[9262-9538]
of the
board. operation.
The Offset:
service
587,
0 612, 637, 662,
Special
types of the DSP
687) Offset: 1850.1
Frequencies
consist of uplink NO NO Yes None
Band3:
Channel Common
Number:
and downlink
Frequencies
(12, 37, 62,
services. The 87, 112,
Indicates
Channel
137, 162, the type
Number:
187,
service
of the types
device.
[1162-1513] of212,
the
Offset:
NO NO Yes None
237,
CPU 262,
consist 287)of
1575
Offset:Special
Indicates 1850.1
theSlave.
Office
Master and
Frequencies NO NO Yes None
Band3:
name ofCommon
the BS.
Channel
Frequencies Number:
Indicates
none Offset: the 0
Channel
software Number:
version of NO NO Yes None
Band4: Common
[937-1288] Offset:
the board.
Frequencies
1525 Special
Indicates the
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Offset:
Number:
Indicates
1805
none Special
Offset:the 0
BootROM
Frequencies
Band4: version
Common NO NO Yes None
of the board.
Channel
Frequencies Number:
(1887,
Indicates
Channel 1912,
the 1937,
test
Number:
1962, 1987, 2012, NO NO Yes None
time.
[1312-1513] Offset:
2037,Special
1450 2062, 2087)
Indicates
Offset: 1735.1
Frequencies the test
NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762, Number:
1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862)Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Indicates
Channel
Frequencies the
Number:
cabinet
(1007, number
1012,
Channel Number: 1032,of
YES NO No None
the
1037,extension
1062, 1087)
[4132-4233] Offset:
Indicates
transmission the
Offset:
0 Special670.1 board.
subrack number of
Band6:
FrequenciesCommon YES NO No None
the extension
Frequencies
Channel Number:
transmission
Indicates the board.
slot
Channel
(782, 787, Number:
807,
number
[4387-4413] of theOffset: YES YES No None
812, 837, 862)
UTRP.
0 Special
Offset: 670.1
Indicates
Frequencies
Band6: Common the type
NO YES No None
of the
Channel sub-board.
Indicates
Frequencies Number:
the alarm
(1037,
status. 1062)
For
Channel Number: Offset:
details
670.1 the
about Band7:
[4162-4188] definition
Offset: NO NO Yes LBFD-004006
Common
of
0 Alarm Status,
Special
Frequencies
see ITU-T X.731.
Frequencies
Channel
Channel Number:
Number:
[2237-2563]
(812, 837) Offset: Offset:
2175 Special
670.1 Band7:
Frequencies
Common
Channel
Frequencies Number:
(2587, 2612,
Channel Number: 2637,
status of the board,
Indicates
which canthe be
operational state of
Uninstalled,
the board,
Starting up,which
Normal,
can be set to
Inconsistent,
Enabled
Unconfigured,or
Disabled.
Power off,Enabled
Fault,
indicates that
Communication
Indicates theorbeE-the NO NO Yes None
services
lost, can
In test,
label,
combination of with
carried a text
on file
the
a maximum
board.
various Disabled
states.of 2For NO NO Yes LBFD-004012
KB. It is used
indicates
example, that to
no
if a board
record
service
is the
can be
not configured
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates the
the main control such
typeas
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
thephysical
bar
module.
operation
code of the status
board of NO NO Yes None
Indicates the
thethe
or board isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.
by the board the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU the of
or DSP result
the NO NO Yes None
of the operation.
board. The service
types of the DSP
consist of uplink NO NO Yes None
and downlink
services.
Indicates The
the type
service types of the NO NO Yes None
of the device.
CPU consist of
Indicates
Master and theSlave.
Office
NO NO Yes None
name of the BS.
Indicates the
software version of NO NO Yes None
the board.
Indicates the
hardware version of NO NO Yes None
the board.
Indicates the
BootROM version NO NO Yes None
of the board.
Indicates the test
NO NO Yes None
time.
Indicates the test
NO NO Yes None
result.
Frequencies
Band4: Common
Channel Number:
Frequencies
(1887,
Channel 1912,
Number: 1937,
1962, 1987,
[1312-1513] Offset: 2012,
2037,Special
1450 2062, 2087)
Offset: 1735.1
Frequencies
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762, Number:
1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Indicates
Channel
Frequencies the
Number:
number
(1007, of
1012,
Channel Number: the1032,
YES NO No None
cabinet
1037, 1062,
[4132-4233] where the
1087)
Offset:
Indicates
Indicates
USCU is the
the
located.
Offset:
0 Special 670.1
number
physical of the
operation
Band6: Common
Frequencies YES NO No None
subrack
status where
of Number:
the board, the
Frequencies
Channel
USCUcan
Indicates
which is located.
the
be slot
Channel
(782, 787, Number:
807,
operational
number
Uninstalled,
[4387-4413] of the state
Offset: of YES YES No None
812,
the 837,
Indicates
board, 862)
the
whichalarm
USCU.
Starting
0 Special up, Normal,
Offset:
can be 670.1
status. For
set to details
Inconsistent,
Frequencies
Band6: Common
about
Enabled the
Unconfigured, or definition NO NO Yes LBFD-004006
Channel
Frequencies
of Alarm Number:
Status,
Disabled.
Power
(1037, off,
1062) Enabled
Fault,
Offset:
Channel
see ITU-TNumber:
indicates X.731.
that
Communication
670.1 Band7:
[4162-4188] Offset: NO NO Yes None
Indicates
services
lost, theorbe
can
In test, E-the
Common
0 Special
label, a text file
carried
combination
Frequencies on theof with
a maximum
board.
various Disabled
states. of 2For NO NO Yes LBFD-004012
Channel
KB. Number:
It is used to
indicates
example,
[2237-2563] that
if a no
board
Offset:
(812,
record
service 837)canOffset:
the be
is not Special
2175
670.1 configured
Band7:
manufacturing
carried
and failsontothe NO NO Yes None
Frequencies
Common
information about
board.
communicate
Channel Number: with
Frequencies
equipment
Indicates thesuchtype as
the main
(2587,
Channel control
2612,
Number: 2637, NO NO Yes None
thethe
of
and board,
board.
transmissionsub-
2662, 2687,
[2012-2338]
board, or 2712,
Offset:
board,
Indicates
2737,
2100 theoptical
2762,
Special physical
the bar
2787,
module.
operation
code of the status
board of NO NO Yes None
Indicates
2812, 2837,
Frequencies the2862,
the
or board
the
description
2887, 2912)
Channel is
cabinet. about
Offset:
Number:
Unconfigured,
the services
2105.1
(2362, Band8:
2387, and
2412,
Communication NO NO Yes None
functions
Common
2437, 2462, provided
2487,
Indicates
lost.
by the 2537,
board
Frequencies the or the
2512, 2562,
manufacturing
cabinet.
Channel Number: date
2587, 2612, 2637, NO NO Yes None
of the board
[2937-3088] or the
Offset:
2662,
Indicates2687) theOffset:
cabinet.
340 Special
2030.1 Band8:of the
manufacturer
Frequencies
Common NO NO Yes None
board or the
Channel
Frequencies
cabinet. Number:
Indicates the issue
none Offset:
Channel 0
number ofNumber: the NO NO Yes None
Band9: Common
[2712-2863] Offset:
board.
Frequencies
340 Special
Indicates
Channel the type
Number:
Frequencies NO NO Yes None
of a board.
[9237-9387] Offset:
Channel Number:
0 Special
none
Indicates the 0object
Offset:
Frequencies
Band9: Common NO NO Yes None
number of a board.
Channel
Indicates
Frequencies Number:
the object
none
type Offset:
of a
Channel Number:board, 0. The
NO NO Yes None
frequency
which is CPU
[8762-8912] of Offset:
the
or
local
DSP.
0 cell must
Special
Indicates the be
the same as of
Frequencies
temperature thata of NO NO Yes None
the bearing
Channel
board. logical
Number:
Indicates
cell.
none Offset: the 0.
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU or DSP the of result
the NO NO Yes None
of the operation.
board. The service
types of the DSP
consist of uplink NO NO Yes None
and downlink
services.
Indicates The the type
service types of the NO NO Yes None
of the device.
CPU consist of
Master and Slave.
487, 512, 537,
[9262-9538] 562,
Offset:
587,
0 612, 637, 662,
Special
687) Offset: 1850.1
Frequencies
Band3:
ChannelCommon Number:
Frequencies
(12, 37, 62, 87, 112,
Channel
137, 162,Number:
187, 212,
[1162-1513]
237, 262, 287) Offset:
1575
Offset: Special
1850.1
Indicates the Office
Frequencies
Band3: NO NO Yes None
name ofCommon the BS.
Channel
Frequencies Number:
Indicates
none Offset: the 0
Channel
software Number:
version of NO NO Yes None
Band4: Common
[937-1288] Offset:
the board.
Frequencies
1525 Special
Indicates the
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Number:Offset:
Indicates
1805
none Special
Offset: the 0
BootROM
Frequencies
Band4: Commonversion NO NO Yes None
of the board.
Channel
Frequencies Number:
(1887,
Indicates
Channel 1912,the 1937,
Number: test
1962, 1987, 2012, NO NO Yes None
time.
[1312-1513] Offset:
2037,Special
1450 2062, 2087)
Indicates
Offset: 1735.1
Frequencies the test
NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762, Number:1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5:
Indicates Common
the
Channel
Frequencies
number ofNumber:
the
(1007,
Channel
cabinet 1012,
Number:
where 1032,
the YES NO No None
1037,
Indicates1062,
[4132-4233]
BBU FAN the
unit 1087)
Offset:
is
Indicates
Offset:
number
0 Special ofthe
670.1 the
located.
physical operation
Band6: Common
subrack
Frequencies where the YES NO No None
status of Number:
Frequencies
BBU
Channel FAN the
unitboard,
is
Indicates
Indicates the
the
which
Channel
located.
(782, canNumber:
787, be
807,
number
operational of thestate slotof
Uninstalled,
[4387-4413] Offset: YES YES No None
812,
where 837,
Indicates
the board,the 862)
BBU
the alarmFAN
Starting
0 Special
Offset: up,which
670.1 Normal,
unit
can is
status.
be located.
For
set details
to
Inconsistent,
Frequencies
Band6: Common
about
Enabled the
Unconfigured, ordefinition NO NO Yes LBFD-004006
Channel
Frequencies
of Alarm Number:
Status,
Disabled.
Power
(1037, off,
1062) Enabled
Fault,Offset:
Channel
see ITU-T
indicates Number:
X.731.
that
Communication
670.1 Band7:
[4162-4188] Offset: NO NO Yes None
Indicates
services
lost, theorbe
can
In test, E-the
Common
0 Special
label, a text file
carried
combination
Frequencies
Frequencies
on the of with
a maximum
board.
various Disabled
states. of 2For NO NO Yes LBFD-004012
Channel
Channel
KB. Number:
Number:
It is used to
indicates
example,
[2237-2563] that
if a no
board
Offset:
(812,
record
service 837)canOffset:
the be
is not Special
2175
670.1 configured
Band7:
manufacturing
carried
and failsontothe NO NO Yes None
Frequencies
Common
information about
board.
communicate
Channel Number: with
Frequencies
equipment
Indicates thesuch type as
the main
(2587,
Channel control
2612,
Number: 2637, NO NO Yes None
thethe
of
and board,
board.
transmissionsub-
2662, 2687,
[2012-2338]
board, or 2712,
Offset:
board,
Indicates
2737,
2100 theoptical
2762,
Special physical
the bar
2787,
module.
operation
code of the status
board of NO NO Yes None
Indicates
2812, 2837,
Frequencies the2862,
the
or board
the
description
2887, 2912)
Channel is
cabinet. about
Number:Offset:
Unconfigured,
the services
2105.1
(2362, Band8:
2387, and
2412,
Communication NO NO Yes None
functions
Common
2437, 2462, provided
2487,
Indicates
lost.
by the 2537,
Frequenciesboardthe or the
2512, 2562,
manufacturing
cabinet.
Channel Number: date
2587, 2612, 2637, NO NO Yes None
of the board or
[2937-3088] the
Offset:
2662, 2687)
Indicates theOffset:
cabinet.
340 Special
2030.1
manufacturerBand8:of the
Frequencies
Common NO NO Yes None
board or the
Channel
Frequencies
cabinet. Number:
Indicates the issue
none Offset:
Channel 0
number ofNumber: the NO NO Yes None
Band9:
[2712-2863] Common Offset:
board.
Frequencies
340 Special
Indicates
Channel the type
Number:
Frequencies NO NO Yes None
of a board.
[9237-9387] Offset:
Channel Number:
0 Special
none
Indicates the 0object
Offset:
Frequencies
Band9: Common NO NO Yes None
number of a board.
Channel
Frequencies Number:
none Offset:
Channel Number: 0. The
frequency of Offset:
[8762-8912] the
local
0 cell must be
Special
the same as that of
Frequencies
the bearing
Channel logical
Number:
cell.
none Offset: 0.
Common
band.
Frequencies
Frequency(MHZ) =
Channel Number:
(Frequency
[10562-10838]
Channel Number /
Offset:
5) + Offset0 Special
Band1:
Frequencies
Common
Channel
IndicatesNumber:
Frequencies the object
none
type ofOffset:
Channel a Number:
board,0
Band2:
[9612-9888] Common Offset: NO NO Yes None
which is CPU or
Frequencies
0 Special the
DSP.
Indicates
Channel
Frequencies Number:
temperature of a NO NO Yes None
[9662-9938]
Channel Offset:
board. Number:
0 Special
none Offset:
Indicates the 0
Frequencies
Band2:
temperature Common
Indicates
Channel theof the
Number:
NO NO Yes None
Frequencies
power
service amplifier.
type of the
(412,
Channel 437,
Indicates 462,
Number:
the result
CPU
487, or
512, DSP 537, of the
562, NO NO Yes None
[9262-9538]
of the
board. operation.
The Offset:
service
587,
0 612, 637, 662,
Special
types of the DSP
687) Offset: 1850.1
Frequencies
consist of uplink NO NO Yes None
Band3:
Channel Common
Number:
and downlink
Frequencies
(12, 37, 62,
services. The 87, 112,
Indicates
Channel
137, 162, the
Number:
187, type
service
of the types
device.
[1162-1513] of212,
the
Offset:
NO NO Yes None
237,
CPU 262,
consist 287) of
1575
Offset: Special
Indicates 1850.1
theSlave.
Office
Master
Frequencies and NO NO Yes None
Band3:
name ofCommon the BS.
Channel
Frequencies Number:
Indicates
none Offset: the 0
Channel
software Number:
version of NO NO Yes None
Band4: Common
[937-1288] Offset:
the board.
Frequencies
1525 Special
Indicates the
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Offset:
Number:
Indicates
1805
none Special
Offset: the 0
BootROM
Frequencies
Band4: Commonversion NO NO Yes None
of the board.
Channel
Frequencies Number:
(1887,
Indicates
Channel 1912,the 1937,
Number:test
1962, 1987, 2012, NO NO Yes None
time.
[1312-1513] Offset:
2037,Special
1450 2062, 2087)
Indicates
Offset: 1735.1
Frequencies the test
NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762, Number:
1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Channel
Frequencies
Indicates Number:
the
(1007,
cabinet 1012,
Channelnumber Number:1032,of YES NO No None
1037,
the EIU 1062,
[4132-4233] in the1087)
Offset:
BBU.
Indicates
Offset:
Indicates
0 Special 670.1the
the
physical
Band6: Common
subrack
Frequencies operation
number of YES NO No None
status
EIUofinNumber:
Frequencies
the
Channel thetheboard,
BBU.
Indicates
which
Channel can the
be
Number:slot
(782, 787, 807,
operational state
number
Uninstalled,
[4387-4413] of the EIUof
Offset: YES YES No None
812,
the 837, the
Indicates
board, 862) alarm
which
in
0 the
Starting BBU.
Special up, Normal,
Offset:
can be 670.1
status. For
set to details
Inconsistent,
Frequencies
Band6: Common
about
Enabled the
Unconfigured, or definition NO NO Yes LBFD-004006
Channel
Frequencies
of Alarm Number:
Status,
Disabled.
Power
(1037, off,
1062) Enabled
Fault,
Offset:
Channel
see ITU-TNumber:
indicates X.731.
that
Communication
670.1 Band7:
[4162-4188] Offset: NO NO Yes None
Indicates
services
lost, theorbe
can
In test, E-the
Common
0 Special
label, a text file
carried
combination
Frequencies
Frequencies
on theof with
a maximum
board.
various Disabled
states. of 2For NO NO Yes LBFD-004012
Channel
Channel
KB. Number:
Number:
It is used to
indicates
example,
[2237-2563] that
if a no
board
Offset:
(812,
record
service 837)canOffset:
the be
is not Special
2175
670.1 configured
Band7:
manufacturing
carried
and failsontothe NO NO Yes None
Frequencies
Common
information about
board.
communicate
Channel Number: with
Frequencies
equipment
Indicates thesuch
type as
the main
(2587,
Channel control
2612,
Number:2637, NO NO Yes None
the
of
and board,
the board.
transmissionsub-
2662, 2687,
[2012-2338]
board, or 2712,
Offset:
board,
Indicates
2737,
2100 theoptical
2762,
Special physical
the bar
2787,
module.
operation
code of the status
board of NO NO Yes None
2812, 2837, 2862,
Frequencies
the
or
2887,board
the is
cabinet.
2912)
Channel Number: Offset:
Unconfigured,
2105.1
(2362, 2387,Band8: 2412,
Communication
Common
2437, 2462, 2487,
lost.
Frequencies
2512, 2537, 2562,
Channel
2587, 2612, Number:
2637,
[2937-3088]
2662, 2687) Offset: Offset:
340 Special
2030.1 Band8:
Indicates the
The downlink
description and
about
uplink frequencies
the services and
of the local cell NO NO Yes None
functions provided
Indicates
must
by thestayboard the
within
or thethe
manufacturing
same
cabinet. frequency date
NO NO Yes None
of the
band.
The board orand
downlink the
Indicates
cabinet.
Frequency(MHZ) the
uplink frequencies=
manufacturer
(Frequency of the
of the local cell NO NO Yes None
board
Channel or the
must stayNumber
within the /
cabinet.
Indicates
5) + Offset the issue
Band1:
same frequency
number
band. of the
Common NO NO Yes None
board.
Frequencies
Frequency(MHZ) =
IndicatesNumber:
Channel
(Frequency the type
NO NO Yes None
of a board.
[10562-10838]
Channel Number /
Offset:
5) + Offset0 Special
Band1:
Indicates
Frequencies the object
Common NO NO Yes None
number
Channel of a board.
IndicatesNumber:
Frequencies the object
none
type ofOffset:
Channel a Number:
board, 0
Band2:
[9612-9888] Common Offset: NO NO Yes None
which is CPU or
Frequencies
0 Special the
DSP.
Indicates
Channel
Frequencies Number:
temperature of a NO NO Yes None
[9662-9938]
Channel Offset:
board. Number:
0 Special
none Offset:
Indicates the 0
Frequencies
Band2:
temperature Common
Indicates
Channel theof the
Number:
NO NO Yes None
Frequencies
power
service amplifier.
type of the
(412,
Channel 437,
Indicates 462,
Number:
the result
CPU
487, or
512, DSP 537, of the
562, NO NO Yes None
[9262-9538]
of the
board. operation.
The Offset:
service
587,
0 612, 637, 662,
Special
types of the DSP
687) Offset: 1850.1
Frequencies
consist of uplink NO NO Yes None
Band3:
Channel Common
Number:
and downlink
Frequencies
(12, 37, 62,
services. The 87, 112,
Indicates
Channel
137, 162, the
Number:
187, type
service
of the types
device.
[1162-1513] of212,
the
Offset:
NO NO Yes None
237,
CPU 262,
consist 287) of
1575
Offset: Special
Indicates 1850.1
theSlave.
Office
Master
Frequencies and NO NO Yes None
Band3:
name ofCommon the BS.
Channel
Frequencies Number:
Indicates
none Offset: the 0
Channel
software Number:
version of NO NO Yes None
Band4: Common
[937-1288] Offset:
the board.
Frequencies
1525 Special
Indicates the
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Number:Offset:
Indicates
1805
none Special
Offset: the 0
Indicates
BootROM the name
version NO NO Yes None
Frequencies
Band4: Common
of
of the eNodeB,
the board.
Channel
Frequencies Number:
which uniquely
(1887,
Indicates
Channel 1912,the 1937,
test
identifies Number:
an NO NO Yes None
1962,
time. 1987,
[1312-1513] 2012,
Offset:
eNodeB within a
2037,Special
1450 2062, 2087)
PLMN.
Indicates the test
Offset: 1735.1
Frequencies NO NO Yes None
The
result.name is a
Band5:
Channel Common
string of aNumber:
Frequencies
(1662, 1687, 1712,
maximum of 64
Channel
1737, 1762,Number:1787, NO NO Yes None
characters. The
[4357-4458]
1812,
Indicates1837, Offset:
the1862)
ID
string cannot be of
0 Special
Offset:
an eNodeB, 1380.1 which
null characters or NO NO Yes None
Frequencies
Band5:
contain Common
uniquely identifies
any of the
Channel
Frequencies
an eNodeB Number:
within a
following
(1007,
Channel
PLMN. 1012,
Number:
This 1032, NO NO No None
characters:
1037, 1062,
[4132-4233]
parametermarks 1087)
Offset:
is closely
question (?),
Offset:
0 Special
associated 670.1 with the
colons
Indicates (:), right
the mobile
Band6:
Frequencies
CGI Common NO NO No None
angleofbrackets
country the
code. cell,This
and
(>),
Frequencies
Channel
is Number:
lefta angle
part of
parameter the
brackets
is CGI.
closely
Channel
(782, 787, Number:
807,
(<), asterisks
associated with(*),the NO NO No None
[4387-4413]
812, 837, Offset:
slashes
CGI of (/),862)
the cell, and
0 Special
Offset: 670.1 (\),
backslashes
is a part (3 decimal
Frequencies
Band6:
bars (|),ofCommon
digits) double
the CGI.
Channel
Frequencies Number:
quotation marks ("),
(1037,
Channel 1062) Offset:
commas Number: (,),
670.1 Band7:Offset:
[4162-4188]
semicolons (;),
Common
0 Special
equal signs (=),
Frequencies
Frequencies
single quotation
expiration date and
protection period.
Normal
Indicates indicates
the
that the
automatic license
power
control
control items
Indicates the are
switch. mobile
within
network the
When the eNodeB code.expiration This
date.
parameter Demo
is powered off is closely
indicates
associated
automatically, that with the
the the
license file is a NO NO No None
CGI of the
TX channels of the cell, and
demo
is a part
RRUs/RFUs file(2and toare 3at
Indicates
least
decimal one the
license
digits) of
shut down. In this NO NO No None
eNodeB
control type.
case, the eNodeBthe
the CGI. item is in
normal
works instate. empty load
Protected indicates NO NO No LOFD-001025
to reduce the power
that the
consumption. license When
Indicates
Indicates
control items the
the enter
the eNodeB
automatic is
power-off NO NO No LOFD-001025
longitude
the protection of the
powered
time of the oneNodeB.
geographic
period
Indicates becausethe location the
automatically, the
of the eNodeB.
current
automatic time passes
power-on NO NO No LOFD-001025
TX and RX
When
the
time ofthe
expiration
theof value
eNodeB. date is
channels the
less
of the than
Indicates control 0,
the this
items,
RRUs/RFUs are
parameter
the license
latitude of the isthe NO NO No None
opened and
represents
revoked, west
RRUs/RFUsastart to
eNodeB. or
A negative
longitude.
mismatch
value When
of thethe the
work. indicates NO NO No None
value
version is
south latitude,
Indicates more
or ESN
the and than
0,
a this parameter
between
positive
automatic
electronic thevalue license
power-off
serial
represents
and
state the
indicates of eNodeB.
number of thenorth
the the east NO NO Yes None
longitude.
After
latitude.
eNodeB.
backplane the protection
If of this the
period
parameter
eNodeB. of 60isdays, set to
the controlall
Poweroff, items NO NO Yes LBFD-004014
enter the default
RRUs/RFUs in the
state. The
eNodeB entervalues the of
the control NO NO Yes LOFD-001025
low power items in
the protected
consumption
Indicates the mode, state
are the
and the cells
position same
information as
are NO YES No None
those
of the in
unavailable. the normal
eNodeB. If this
state. Emergency
Indicates
parameter the is set format to
Indicates
indicates
of geographical
Normal, thethe the
that NO NO No None
Indicates
monitoring
license the period
eNodeBofruns
coordinates. the
latitude
for KPI
eNodeB ofenters
alarms. the The the
normally.
eNodeB
monitoring
emergency in period
the
state. is NO YES No None
Indicates
WGS-84 the
used
This in
state
longitude one can
of the of the
be
coordinates.
following ways:
started
eNodeBwhen in thethe1. If NO YES No None
Indicates
the monitoring
license is the
in thealarm
WGS-84
occur
period
normal threshold.
is
or set
demo to 15
coordinates.
Indicates the
The
state.delay
minutes,
Indicates In the 30
theandtype jitter
alarm YES YES No None
of a KPI
alarm
minutes,
emergency alarm.
threshold
or 60 state, of
clearance
the transport
minutes,
dynamic
threshold.
Indicates The
whether
network
DETECTBEGINTIM
statistical
delay and are control
jitterin units NO YES No None
to report the alarm.
of
E ms.
is
items
alarm The packet
invalid.
and
threshold For of
loss
example,rate of
performance
the transport if athe control NO YES No None
transport
command
items areare
network network
forinto
set aunits
KPI
the
Indicates
and
alarm
maximum
of ms.the TX
monitor
The the packet
packet is
minimum
loss
loss rate
started ratebetween
registered number
on
of the NE
values.
the of NO YES No None
KPI
The checks.
port
8:00 are
to 8:05
values
transport innetwork ofIf other
units the of
number
permillage.
(excluding
control
and theitems of actual
TX Other
8:05)
packet
checks
alarm
and
remain
loss the is
thresholds
ratethe less
monitoring
on thethan
same. NE NO NO No None
the
are
period
The value
in units
is
emergency
port are inthe
Indicates of
15 of
unitsthis of
parameter,
percentage.
minutes,
state laststhe
permillage.
monitoring KPI
seven KPIs
Other
start
alarms may not be NO NO No None
generated
days for
alarm
time every KPIfrom
thresholds time.
alarms.
reported
8:00
Each
are
This toeNodeB
inparameter
units or
8:15of ofisRcleared.
(excluding
version
percentage.
valid only can 8:15)
when enter are
the NO NO No None
monitored.
the emergency
monitoring 2. If theis
period
Indicates
monitoring
state
one day. for aThe the periodstart is
number
set
time tomust
maximum one of of detection
day,
be three
on the NO NO No None
periods.
DETECTBEGINTIM
times
Indicates
full hour. in itsthe life
E is valid.
cycle.
number of For the
YES NO No None
example,
cabinet if a the
where
command
PEU is located. for a KPI
alarm monitor is
started between
8:00 to 8:05
(excluding 8:05)
and the monitor
starts at 8:00, the
Indicates
Indicates the the
number of
physical the
operation YES NO No None
subrack
status ofwhere
the board,the
PEU
whichiscan
Indicates located.
the
be slot
operational
number of the
Uninstalled, state
PEU of YES YES No None
Indicates
the
in theboard,
BBU. the alarm
which
Starting up, Normal,
status.
can be For set to
Inconsistent, details
about
Enabled orthe
Unconfigured, definition NO NO Yes LBFD-004006
of Alarm
Disabled.
Power Status,
off, Enabled
Fault,
see ITU-T
indicates
Communication X.731.
that
Indicates theorbe
E-the NO NO Yes None
services
lost, In test,can
label,
carrieda on
combination textthefile
of with
a maximum
board.
various Disabled
states.of 2For NO NO Yes LBFD-004012
KB. It
indicatesis used
that
example, if a board to
no
record
service the
can
is not configured be
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates
the main control such
the type as
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
physical
the bar
module.
operation
code of the status
boardof NO NO Yes None
Indicates the
the
or theboard isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.the board
by the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU or DSP the of
result
the NO NO Yes None
of the operation.
board. The service
types of the DSP
consist of uplink NO NO Yes None
and downlink
services. The
Indicates the type
service types of the NO NO Yes None
of the device.
CPU consist of
Indicates
Master and theSlave.
Office
NO NO Yes None
name of the BS.
Indicates the
software version of NO NO Yes None
the board.
Indicates the
hardware version of NO NO Yes None
the board.
Frequencies
undercurrent
Band3: Common alarm
Channel
occur Number:30
threshold:
Frequencies
none
mA;
Channel Offset:
undercurrent 0
Number:
Band4:
alarm Common
clear
[937-1288] Offset:
Frequencies
threshold:
1525 Special 40 mA;
Channel Number:
overcurrent
Frequencies alarm
[1537-1738]
occur
Channel threshold: Offset:
Number:
Indicates
1805
170
nonemA; Special
Offset: the 0
BootROM
Frequencies
overcurrent
Band4: Common version
alarm NO NO Yes None
of the
Channel
clear board.
Number:
threshold:
Frequencies 150
(1887,
mA.
Indicates
Channel 1912,
the 1937,
Number:test
1962, NO NO Yes None
time.241987,
For
[1312-1513] dB non- 2012,
Offset:
2037,
AISG 2062, 2087)
TMA:
1450 Special
Indicates
Offset:
undercurrent
Frequencies the alarm
1735.1 test
NO NO Yes None
result.
Band5:
occur Common
Channel Number:40
threshold:
Frequencies
mA;
(1662, undercurrent
1687, 1712,
Channel
alarm
1737, clear
1762,Number:
1787, NO NO Yes None
[4357-4458]
threshold:
1812, 1837, Offset:
601862)
mA;
0 Special
overcurrent
Offset: 1380.1 alarm
Frequencies
occur NO NO Yes None
Band5:threshold:
Indicates Common
the
Channel
310
cabinetmA;number
Frequencies Number: of
(1007,
overcurrent
Channel
the RRU 1012,
Number:
or RFU 1032,
alarm YES NO No LOFD-001024
1037,
Indicates
clear
where 1062,
thethe
threshold:
[4132-4233] 1087) 280
Offset:
antenna
Offset:
subrack
mA.
0 Special
port 670.1
is located. of
number
Band6:
the
For RETCommon
RRU
Frequencies or RFU
(coaxial) YES YES No LOFD-001024
Indicates
Frequencies
where
only: the
theNumber: slot
antenna
undercurrent
Channel
number
Channel
port
alarm is787, of the
Number:
located.
occur RRU
(782, 807,
or RFU
[4387-4413]
threshold: where the
Offset:
25 mA; YES YES No LOFD-001024
812, 837, 862)
antenna
Indicates
0 Special
undercurrent port
the is
alarm
Offset: 670.1
located.
number
Frequencies
clear of the 33
threshold:
Band6: Common YES YES No LOFD-001024
antenna
Channel
mA; port
Number:
overcurrent
Frequencies on the
RRU
(1037,or
alarm
Channel RFU.
1062)
occurNumber:Offset:
Indicates
670.1
threshold:
[4162-4188]Band7:the
150 ALDmA;
Offset: NO NO No LOFD-001024
power
Common
overcurrent
0 Special supply alarm
switch.
Indicates
Frequencies
clear Whenthe an120
threshold:
Frequencies
ALD needs
overcurrent
Channel Number:
mA.
Channel power
alarm
Number: NO NO No LOFD-001024
supply,
clear
For 12837)
Indicates
(812, set
threshold.
[2237-2563] dBthe the
TMA
Offset:ALD
Offset:
and
power
When
2175
RET supply
the
Special
670.1orBand7:
overcurrent ALD
12 dB switch
TMA
alarm
to ON. only: NO NO No LOFD-001024
current
Frequencies
(AISG)
generating
Common value is less
Indicates
than
Channel this
undercurrent
threshold.
Frequencies the
threshold,
Number:
When alarm
undercurrent
the
(2587,
occur
the overcurrent
ALD
Channel 2612,
threshold:
current
Number:alarm
2637, 30 NO NO No LOFD-001024
clear
alarm
mA;
value threshold.
is
is
[2012-2338] cleared.
2662,undercurrent
2687,
greater2712,
Offset:
Indicates
When the
thethreshold,
ALD
2737,
alarm
than
2100 2762,
clear
this
Special 2787,
undercurrent
current value alarm
is NO NO No LOFD-001024
2812,
threshold:
an 2837,
overcurrent
Frequencies 40 2862,
mA;
generating
greater than this
2887,
overcurrent
alarm 2912)
is
Channel Number: Offset:
alarm
reported.
threshold.
threshold, When
the2412,
2105.1threshold:
occur
(2362, Band8:
2387,
the ALD
undercurrent
Indicates current
the alarm
DL NO NO No LOFD-001024
Common
450
2437, mA; 2462, 2487,
value
is is
cleared.
delay of smaller
the TMA.
Frequencies
overcurrent
2512,
than 2537,
this 2562,It
alarm
threshold,
Indicates
should
Channel
clear be the feeder
specified
Number:
threshold:
2587,
an 2612,
undercurrent
Indicates
length.
according the
to UL400
2637,
the
NO NO No LOFD-001024
[2937-3088]
mA.
2662, of 2687) Offset:
Offset:It
alarm
delay is
specification reported.
the TMA.
340 24
For
2030.1 Special
dB TMA and
Band8:
should
provided be specified NO NO No LOFD-001024
Common or 24by
Frequencies
RET
according dB
to
the
theTMA
equipment
Channel
(AISG):
Frequencies Number:
specification
manufacturer.
none Offset: 0alarm
undercurrent
Channel
provided Number:
Typically, by
thisthe NO NO No LOFD-001024
Band9:threshold:
occur
[2712-2863] Common Offset:40
equipment
parameter is less
Frequencies
mA;
340 undercurrent
Indicates
Special the
manufactory.
than 30 ns.
Channel
alarm
Frequencies
observed clearNumber:
current of NO NO Yes LOFD-001024
Typically, this
[9237-9387]
threshold: Offset:
parameter 60
Channel
the ALD.
Indicates Number:
the mA;
actual
is less
0 Special
overcurrent
none
status Offset:
of the alarm
0
ALD
than 30 ns. NO NO Yes LOFD-001024
Frequencies
occur
powerthreshold:
Band9: Common
supply
Indicates the
Channel
850 mA;
Frequencies
switch. number Number:
cabinet of
none Offset:
overcurrent
Channel 0. The
alarm
the boardNumber: where the YES NO No None
frequency
clear of the750
threshold:
[8762-8912]
Indicates
CPRI portthe is Offset:
local
mA.
0 cell
Specialnumber
subrack must beof
located.
the
If thesame as
previously
Frequencies
the board where the that of YES YES No None
Indicates
the bearing
listed
Channel
CPRI the
threshold
portNumber: slot
islogical
number
cell. Offset:
cannot
none
located. of the0.
meet the
board
requirements,the
where you YES YES No None
CPRI
can chooseport isto
located.
customize the
threshold according
to the actual device
type. The
customized
threshold should
meet the following
Indicates the
number of the CPRI YES YES No None
port.
Indicates the line
rate at the CPRI NO NO Yes None
port.
Indicates the
Indicates the
Indicates
VSWR the post-
alarm
administrative
administrative state
state NO NO Yes None
processing
of the board. switch.
The
of the
When CPRI
this port.
administrative state
parameter
Indicates
of the board theis can
set to
be NO NO No None
ON
VSWR
locked,andalarm
if the post-or
unlocked,
current
shuttingVSWR
processing down. is For
greater
threshold. than
details, seeIf ITU-T the
the NO NO No None
VSWR
VSWR
X.731. alarmpost-alarm post-
post-processing
processing
Indicates the switch is
threshold, the post- NO NO No None
set to ON,
VSWR alarm the TX
processing
channel is When
threshold. is
shut
performed
Indicates
down
the the
whenVSWR
current and
the the NO NO No None
TX
exceeds theis shut
VSWR channel
position isof the
greater RRU
down.
or
thanRFU the on a
value
threshold, an alarm chain
of
or
thisring. It is
parameter.
is reported. NO YES No None
calculated starting
Indicates
from the head
Indicates the
the of
Indicates
topology the ID ofof
position NO YES No None
the
the chain
RRUmode or ring.
chain/ring.
working
the RRU or RFU of on
the RRU
a chain/ring. or RFU.If no
The MRFU NO NO No None
RHUB is or
MRRU
configured, supportsTP can
one or more
only be set to NO YES No None
standards,
TRUNK. the
LRFU
Indicates supports
the LTE
(FDD),
number of RXand the NO YES No None
LRRU supports LTE
channels.
Indicates
(TDD) andthe LTE
number
(FDD). of TX NO YES No None
channels.
Indicates the
number of carriers
NO NO Yes None
on each RX
Indicates
channel. the
number of carriers
NO NO Yes None
on each TX
channel.
Indicates the
minimum UL NO NO Yes None
frequency.
Indicates the
maximum UL NO NO Yes None
frequency.
Indicates the
minimum DL NO NO Yes None
frequency.
Indicates the
maximum
Indicates the DL NO NO Yes None
frequency.output
maximum
power on a TX
NO NO Yes None
channel of the RRU
or RFU. The error is
Indicates
precise tothe +/-1UL W. NO NO Yes None
channel gain.
Indicates the
bandwidth
NO NO Yes None
supported by the
UL channel.
Indicates the
temperature of the NO NO Yes None
PA.
Indicates the
number of scanned
Indicates the NO NO Yes None
hops, which is
access direction of
counted
Indicates from 0.
the which
serial
the services,
number
can be of the RRU NO NO Yes None
or RFU. the
Indicates
CONNECTHEAD(A
Indicates the
standard
ccess
physical from of chain
the
operation NO NO Yes None
RRU or
head
status orofRFU
ring in the
the head),
board,
scanning
Indicates
which canthe
CONNECTTAIL(Ac result.
be
operational
cess from ring
Uninstalled, state of
tail), NO NO Yes None
Indicates
the board,
CONNECTBOTH(A the alarm
which
Starting up, Normal,
status.
can
ccess For
befrom
set to
Inconsistent, details
both
about
Enabled the
ends of the
Unconfigured, definition
or ring), NO NO Yes LBFD-004006
of Alarm
Disabled.
SEPERATEBYBRE
Power Status,
off, Enabled
Fault,
see ITU-T
indicates
AK(Seperated
Communication X.731.
that by
Indicates theorbe
E- NO NO Yes None
services
break can
lost, Inpoints),
test, or
the
label,
carried a on
textthe
LINKDOWN(Link
combination file
of with
a maximum
board. states. 2For
down). Disabled
various of NO NO Yes LBFD-004012
KB.
example,used
It
indicatesis that to
no
if a board
record
service the
can
is not configured be
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates
the main control such
the type as
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
physical
the bar
module.
operation
code of the status
boardof NO NO Yes None
Indicates the
the
or theboard isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.the board
by the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU or DSP the of
result
the NO NO Yes None
of the operation.
board. The service
types of the DSP
consist of uplink NO NO Yes None
and downlink
services. The
Indicates the type
service types of the NO NO Yes None
of the device.
CPU consist of
Indicates
Master and theSlave.
Office
NO NO Yes None
name of the BS.
Band3: Common
Channel Number:
Frequencies
(12, 37, 62, 87, 112,
Channel
137, 162,Number: 187, 212,
[1162-1513]
237, 262, 287) Offset:
1575 Special
Offset: 1850.1
Frequencies
Band3: Common
Channel Number:
Frequencies
Indicates
none Offset:the 0
Channel
software Number:
version of NO NO Yes None
Band4:
[937-1288] Common Offset:
the board.
Frequencies
1525
IndicatesSpecialthe
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Offset:
Number:
Indicates
1805
none Special
Offset:the 0
BootROM
Frequencies
Band4: Common version NO NO Yes None
of the
Channel board.
Frequencies Number:
(1887,
Indicates
Channel 1912,the 1937,
Number: test
1962, NO NO Yes None
time. 1987, 2012,
[1312-1513] Offset:
2037, 2062, 2087)
1450 Special
Indicates
Offset:
Frequencies the test
1735.1 NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762, Number:
1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Indicates
Channel Number:
Frequencies the
number
(1007, 1012,
Channel of the1032,
Number: YES NO No None
cabinet
1037, where
1062,
[4132-4233] the
1087)
Indicates
RFU is theOffset:
located.
Offset:
0 670.1
Specialof the
number
Band6:
Frequencies Common YES YES No None
subrack where the
Frequencies
Channel
Indicates Number:
the
RFU is located.
Indicates the type
Channel
(782,
number 787, ofNumber:
807,
the slot
of the RF
[4387-4413] module.
Offset: YES YES No None
812, 837,
where the 862)RFU is
MRFUs
0 Special
Indicates
Offset:
located. ofthe
670.1 different
versions
Frequencies
administrative
physical
Band6: Common can
operation state NO YES No None
support
Channel
of ofdifferent
the board.
status
Frequencies Number:The
the board,
working
Indicates
(1037,can
administrative
which
Channel modes.
1062)the
be Offset:
Number: state
Thethe boardsupports
670.1
of LRFU
operational
Band7:
Uninstalled,
[4162-4188] state
can
Offset:of
be NO NO No None
Indicates
only
the the
board,
Common
locked,
Starting LOthe
which
unlocked,
0 Specialup, Normal, alarm
mode. or
status.
can be
Frequencies
shutting For
set
Inconsistent,
Frequencies down.details
to For
about
Enabled
Channel
details, the
Unconfigured,
Channel ordefinition
Number:
see ITU-T
Number: NO NO Yes LBFD-004006
of Alarm
Disabled.
[2237-2563]
X.731.
Power
(812, Status,
Enabled
Offset:
off, Fault,
837) Offset:
see
2175 ITU-T
indicatesSpecial
Communication
670.1 Band7: X.731.
that
Indicates theorbeE-the NO NO Yes None
services
Frequencies
lost,
Common In test,can
label,
Frequencies with
carried
Channel a
combination text
on file
the
Number:
of
a maximum
board.
(2587,
various
Channel Disabled
2612,
states. of2637,
Number: 2For NO NO Yes LBFD-004012
KB. It
indicatesis
2662, 2687,
example,
[2012-2338] used
that to
no
if a2712,
board
Offset:
record
service
2737,
is the
can be
2762,
not Special
2100 configured 2787,
manufacturing
carried
2812,
and fails
Frequencies ontothe
2837, 2862, NO NO Yes None
information
board.
2887, 2912)
communicate
Channel Number: about
Offset:
with
equipment
Indicates
2105.1
the main
(2362, the
Band8: such
control
2387, type
2412,as
the board, sub- NO NO Yes None
of
andthe
Common
2437, board.
transmission
2462, 2487,
board,
Frequencies
board,
Indicates
2512, 2537,or
theoptical
physical
the bar
2562,
module.
Channel
operation
code
2587,of2612, Number:
the status
board
2637, of NO NO Yes None
Indicates the
[2937-3088]
the
or board
the
2662, isabout
cabinet.
2687)
description Offset:
340
2030.1Special
Unconfigured,
the servicesBand8: and
Frequencies
Communication
Common NO NO Yes None
functions provided
Channel
Indicates
lost.
Frequencies
by the board Number:
the or the
none
manufacturing
Offset:
Channel Number:
cabinet. 0 date
NO NO Yes None
Band9:
of the board
[2712-2863] Common or the
Offset:
Indicates
Frequencies
cabinet. the
340 Special
manufacturer
Channel Number: of the
Frequencies NO NO Yes None
board or the Offset:
[9237-9387]
Channel Number:
cabinet.
Indicates
0 Special the 0issue
none Offset:
number
Frequencies
Band9: of the
Common NO NO Yes None
board.
Channel Number:
Frequencies
none Offset:
Indicates
Channel the 0.
Number: The
type
NO NO Yes None
frequency
of a board.of Offset:
[8762-8912] the
local cell must be
0 Special
the same as that of
Frequencies
the bearing
Channel logical
Number:
cell. Offset: 0.
none
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU or DSP the of result
the NO NO Yes None
of the operation.
board. The service
Indicates the
types
VSWRofalarm the DSP post-
consist
processinguplink
of switch. NO NO Yes None
and
When downlink
this
services.
Indicates The
Indicates the
parameter the typeto
is set NO NO Yes None
service
of
ON theand types
device.
if the of the
VSWR alarm post-
CPU consist
current VSWR is of
processing
Master
greater and than Slave.
the NO NO No None
threshold. If the
VSWR post-alarm
VSWR alarm post-
post-processing
processing
Indicates the switch is
threshold, the NO NO No None
set to ON,
VSWR alarm the post-
TX
processing
channel
threshold. is Whenis
shut
performed
Indicates
down when
the current theand
the the
VSWR NO NO No None
TX
VSWR channel
position
exceeds isof is shut
the
greater
the RRU
down.
or RFU on
than the value
threshold, anchain
a of
alarm
or
this
is ring. It is
parameter.
reported. NO YES No None
calculated starting
Indicates
from the head
Indicates the
the of
Indicates
topology the ID ofof
position NO YES No None
the RRU
the chain chain/ring.
or ring.
working
the RRUmode or RFU of on
the RRU or
a chain/ring. If no RFU.
The MRFU NO NO No None
RHUB is or
MRRU
configured, supports TP can
one or more
only be set to NO YES No None
standards,
TRUNK. the
LRFU supports
Indicates the LTE
(FDD), and
number of RX the NO YES No None
LRRU
channels. supports LTE
Indicates
(TDD) andthe LTE
number
(FDD). of TX NO YES No None
channels.
Indicates the
number of carriers
NO NO Yes None
on each RX
Indicates
channel. the
number of carriers
NO NO Yes None
on each TX
channel.
Indicates the
minimum UL NO NO Yes None
frequency.
Indicates the
maximum UL NO NO Yes None
frequency.
Indicates the
minimum DL NO NO Yes None
frequency.
Indicates the
maximumthe
Indicates DL NO NO Yes None
frequency.
maximum output
power on a TX
NO NO Yes None
channel of the RRU
or RFU. The error is
precise to +/-1 W.
of the local cell
Channel
must stayNumber within the /
5) + Offset
same frequency Band1:
Common
band.
Frequencies
Frequency(MHZ) =
Channel
(Frequency Number:
[10562-10838]
Channel Number /
Offset:
5) 0 Special
+ Offset Band1:
Indicates
Frequencies the UL
Common NO NO Yes None
channel gain.
Channel
IndicatesNumber:
Frequencies the
none
Channel Offset:
bandwidth Number:0
Band2:
[9612-9888] Common NO NO Yes None
supported byOffset: the
Frequencies
0
ULSpecial
channel.
Indicates the
Channel Number:
Frequencies
temperature of the NO NO Yes None
[9662-9938]
Channel Offset:
Number:
PA.
Indicates the
0 Special
none Offset: 0
number
Frequencies of scanned
Band2:
Indicates Common
the NO NO Yes None
hops,
Channel which is
Number:
Frequencies
access direction of
counted
Indicates
(412, 437, from
the
462, 0.
serial
Channel
the services, Number:which
number
487, 512,
[9262-9538]
can be of537,
the RRU
562,
Offset: NO NO Yes None
or RFU.
587, 612,
Indicates
0 Special
CONNECTHEAD(A 637,
the 662,
687) Offset:
standard
Frequencies of
ccess from chain 1850.1
the
Band3: NO NO Yes None
RRU
head or
Channel or Common
RFU
Number:
ring in the
head),
Frequencies
scanning
(12, 37, 62,
CONNECTTAIL(Ac result.
87, 112,
Channel
137, fromNumber:
cess 162, 187, 212,
ring tail), NO NO Yes None
[1162-1513]
237, 262, 287)
CONNECTBOTH(A Offset:
1575
ccessSpecial
Offset:
Indicates 1850.1
from theboth
Office
Frequencies
Band3: NO NO Yes None
ends of
name ofCommon
the
thering),
BS.
Channel
Frequencies
SEPERATEBYBRE Number:
Indicates
none Offset:the 0
Channel
AK(Seperated
software Number:
version byof NO NO Yes None
Band4:
[937-1288]
break Common
points), Offset:
or
the board.
Frequencies
1525 Special
LINKDOWN(Link
Indicates the
Channel
down). Number:
Frequencies
hardware version of NO NO Yes None
[1537-1738]
Channel
the board. Offset:
Number:
Indicates
1805
none Special
Offset:the 0
BootROM
Frequencies
Band4: Common version NO NO Yes None
of the
Channel board.
Frequencies Number:
(1887,
Indicates
Channel 1912,the 1937,
Number:test
1962, NO NO Yes None
time. 1987, 2012,
[1312-1513] Offset:
2037, 2062, 2087)
1450 Special
Indicates
Offset: the test
1735.1
Frequencies NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762,Number:
1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Channel
IndicatesNumber:
Frequencies the
(1007,
cabinet1012,
Channel Number:
number 1032,
of YES NO No None
1037,
the RRU.1062, 1087)
[4132-4233] Offset:
Offset:
Indicates
0 Special 670.1the
Band6: Common
subrack
Frequencies number of YES YES No None
Frequencies
the RRU.Number:
Channel
Channel
(782, 787,
Indicates Number:
807,
the slot
[4387-4413] Offset: YES NO No None
812, 837,
number
Indicates 862)
ofthethe RRU.
RRU
0 Special
Indicates
Offset:
name, 670.1
whichthe istype
a
Frequencies
of the of
Band6:
string RRU.a The
Common NO NO No None
Channel
MRRUs
Frequencies
maximum Number:
of different
of 30
Indicates
(1037,
versions
Channel 1062)the
can
Number:Offset:
characters.
administrative state
670.1
support Band7:
[4162-4188] different
Offset: NO YES No None
of the
Common
work
0 board.
modes.
Special the The
The
Indicates
administrative
LRRU support state
Frequencies
Frequencies only
operational
of the
Channel board state
can be
Number: of NO NO No None
the LO
Channel
Indicates and LO_TD
Number:
the alarmor
the board,
locked,
[2237-2563] which
unlocked,
Offset:
modes
(812,
status. respectively.
837)
For Offset:
details
can beSpecial
shutting
2175 set to
down. For
670.1
about the
Enabled Band7:
ordefinition NO NO Yes LBFD-004006
details,
Frequencies
Common see ITU-T
of Alarm Status,
Disabled.
X.731. Enabled
Channel
ITU-TNumber:
Frequencies
see X.731.
indicates
(2587, 2612, that 2637,
Channel Number: NO NO Yes None
services can
2662, 2687, 2712, be
[2012-2338]
carried on the Offset:
2737,
2100 2762,
Special 2787,
board.
2812, Disabled
2837, 2862,
Frequencies
indicates thatOffset:
no
2887, 2912)
Channel Number:
service can
2105.1 2387,
Band8: be
(2362,
carried on the2412,
Common
2437, 2462, 2487,
board.
Frequencies
2512, 2537, 2562,
Channel
2587, 2612, Number:
2637,
Uninstalled,
Starting up, Normal,
Inconsistent,
Unconfigured,
Power off, Fault,
Communication
Indicates
lost, In test,theorE-the
label, a text file
combination of with
a
various states. 2For
maximum of NO NO Yes LBFD-004012
KB. It is used
example, to
if a board
record the
is not configured
manufacturing
and fails to NO NO Yes None
information
communicate about
with
equipment
Indicates such
the type
the main control as
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
physical
the bar
module.
operation
code of thestatus
boardof NO NO Yes None
Indicates the
the
or theboard isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.the board
by the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU or DSP the of result
the NO NO Yes None
of the
board. operation.
The service
Indicates the
types
VSWRofalarm the DSP post-
consist
processinguplink
of switch. NO NO Yes None
and
When downlink
this
services.
parameterThe
Indicates the typeto
is set
Indicates the NO NO Yes None
service
of the types
device.
ON andalarm of the
if the post-
VSWR
CPU
current consist
VSWR of is
processing
Master
greater and
than Slave.
the NO NO No None
threshold. If the
VSWR alarm post-alarm post-
post-processing
processing
Indicates the switch is
threshold, the NO NO No None
set to ON,
VSWR alarm the post-
TX
processing
channel is When
threshold. is
shut
performed
Indicates
down
the the
whenVSWR
current and
the the NO NO No None
TX
exceeds theis shut
VSWR channel
position isof the
greater RRU
down.
or
thanRFUthe on a
value
threshold, an alarm chain
of
or
this
is ring. It is
parameter.
reported. NO YES No None
calculated starting
Indicates
from the head
Indicates the
the of
Indicates
topology the ID ofof NO YES No None
the chainposition
the RRU or ring.
chain/ring.
working
the RRUmode or RFU of on
the RRU or
a chain/ring. If no RFU.
The MRFU NO NO No None
RHUB is or
MRRU
configured, supportsTP can
one or more
only be set to NO YES No None
standards,
TRUNK. the
LRFU supports LTE
(FDD), and the
LRRU supports LTE
(TDD) and LTE
(FDD).
Indicates the
number of RX NO YES No None
channels.
Indicates the
number of TX NO YES No None
channels.
Indicates the
number of carriers
NO NO Yes None
on each RX
Indicates
channel. the
number of carriers
NO NO Yes None
on
Theeach TX and
downlink
channel.
Indicates the
uplink frequencies
minimum
of the local ULcell NO NO Yes None
frequency.
must stay within the
Indicates the
same frequency
maximum UL NO NO Yes None
band.
frequency.
Frequency(MHZ)
Indicates the =
(Frequency
minimum DL NO NO Yes None
Channel
frequency. Number /
Indicates
5) + Offsetthe Band1:
maximumthe
Indicates
Common DL NO NO Yes None
frequency.
maximum output
Frequencies
power onNumber:
Channel a TX
NO NO Yes None
channel of the RRU
[10562-10838]
or RFU.0The
Offset: Special
error is
Indicates
precise tothe
Frequencies +/-1UL W. NO NO Yes None
channel
Channel gain.
Number:
Indicates the
none Offset: 0
bandwidth
Band2: Common NO NO Yes None
supported by the
Frequencies
UL channel.
Indicates the
Channel Number:
temperature of the NO NO Yes None
[9662-9938] Offset:
PA.
Indicates
0 Special the
number of scanned
Frequencies
Indicates the NO NO Yes None
hops, which
Channel is
Number:
access direction of
counted
Indicates
(412, 437,from
the
462, 0.
serial
the services, which
number
487,
can be512,of537,
the RRU562, NO NO Yes None
or RFU.
587, 612, the
Indicates
CONNECTHEAD(A637, 662,
687)
ccess Offset:
standardfrom 1850.1
of chain
the
Band3: NO NO Yes None
RRU or
head or Common
RFU in the
ring head),
Frequencies
scanning result.
CONNECTTAIL(Ac
Channel
cess fromNumber:
ring tail), NO NO Yes None
[1162-1513]
CONNECTBOTH(A Offset:
1575
ccess Special
from both
Indicates the Office
Frequencies
ends of NO NO Yes None
name ofthe
thering),
BS.
Channel Number:
SEPERATEBYBRE
Indicates
none the 0
Offset:
AK(Seperated
software version byof NO NO Yes None
Band4:points),
break Common or
the board.
Frequencies
LINKDOWN(Link
Indicates the
Channel
down). Number:
hardware version of NO NO Yes None
[1537-1738]
the board. Offset:
Indicates
1805 the
Special
BootROM version
Frequencies NO NO Yes None
of the board.
Channel Number:
(1887,
Indicates the 1937,
1912, test
1962, NO NO Yes None
time. 1987, 2012,
2037, 2062, 2087)
Indicates the test
Offset: 1735.1 NO NO Yes None
result. Common
Band5:
Frequencies
Channel Number: NO NO Yes None
[4357-4458] Offset:
0 Special
Frequencies
Channel Number:
(1007, 1012, 1032,
1037, 1062, 1087)
Offset: 670.1
Band6: Common
[1312-1513] Offset:
1450 Special
Frequencies
Channel Number:
(1662, 1687, 1712,
1737, 1762, 1787,
1812, 1837, 1862)
Offset: 1380.1
NO NO Yes None
Band5: Common
Indicates the ID of
Frequencies
the RRU chain/ring.
Channel
It uniquely Number:
identifies YES YES No None
[4132-4233]
a chain/ring within Offset:
0
an Special
eNodeB.
Indicates the type
Frequencies NO YES No None
of the topology.
Channel Number:
Indicates the
(782, 787, 807,
backup mode of the NO YES No None
812, 837, the
Indicates 862)
RRU chain/ring.
Offset: 670.1
cabinet number of
Band6:
the board Common
where the NO YES No None
Indicates
Frequencies
head CPRI the port is
subrack
located. number
Channel Number:of
the board where
[4162-4188] Offset: the NO YES No None
Indicates
head
0 SpecialCPRI the slotis
port
number
located.
Frequencies of the
board where
Channel Number: the NO YES No None
head
(812, CPRI
837)the port
Offset: is
Indicates
located.
670.1
number Band7:
of the head NO YES No None
Indicates
Common
CPRI port.the
cabinet
Frequencies number of
the boardNumber:
Channel where the NO NO No None
Indicates
tail CPRI port
[2012-2338] theOffset:
is
subrack
located.
2100 Special number of
the board where the
Frequencies NO NO No None
Indicates
tail CPRI the slot
port is
ChannelofNumber:
number the
located.
(2362, 2387, the 2412,
board where tail NO NO No None
2437, 2462,
CPRI port is 2487,
Indicates
2512,
Indicates
located. 2537, the2562,
the
number
2587, 2612,
Indicates
position of the
ofthe tail
2637, NO NO No None
CPRI
2662, port.
access
breakpoint2687)
type1 of Offset:
onthe the
Indicates
2030.1
RRU. theaccess
If Band8:
the
RRU chain/ring.
position
Common
type of port, NO NO No None
Whenisthis local
breakpoint
Frequencies
the LBBP isis
parameter 2 on
setthe to
RRU
Channel
connected
255, chain/ring.
Number:
to the
the breakpoint NO NO No None
When
[2712-2863]
RRU/RFU
is this byOffset:
disabled. using
parameter
340
a CPRISpecial
port. is If
setthe to
255, thetype
Frequencies
access breakpoint
is peer NO NO No None
is disabled.
Channel
port, the local
Number: LBBP
Indicates
none
is connected
Offset: the 0to
levels
the
of theLBBP
Band9:
peer RRUCommon by using NO NO Yes None
Indicates the
chain/ring.
Frequencies
the
numberIDX2ofport on
Channel
the backplane,
RRUs/RFUs Number: and
carried NO NO Yes None
[8762-8912]
the peer
Indicates
on the RRU LBBP
the Offset:
is
0
then
Special
cabinet connected
chain/ring. number to of
Frequencies
the RRU/RFU.
RRU where the YES NO No None
Indicates
Channel
RX channel theis
Number:
subrack
none Offset: 0. of
located. number
the RRU where the YES YES No None
RX channel
Indicates theisslot
located. of the RRU
number
YES YES No None
where the RX
channel isthe
Indicates located.
attenuation
Indicates theoflogical
number of the an
RX YES YES No None
RX channel.
channel.
switch of the WhenRX
this parameter
channel. This is
not NO NO No None
switch is used to the
set properly,
total
opengain or closeof the the RX
link becomes
RX channel. over
NO NO No None
high, the anti-
interference
capability
decreases, and the
reported RSSI
becomes
inaccurate.
Indicates the
antenna mode of
the sector. When
the antenna is in
Indicates
1T1R mode, the one actual
longitude
physical
group of of
status the of NO NO Yes None
geographic
the RX location
channel.
parameters must be
of the sector.
Indicates
specified thethe
for When
sector
the value is less YES YES No None
number. port, which
antenna
than
are the0, this
cabinet
parameter
number, subrack NO YES No None
represents
number, slotthe west
Indicates
longitude. the
When the
number,
latitude and
of theport
value
number. is greater
When the NO YES No None
geographic
than 0, this location
antenna
of is
the sector. in 1T2R
parameter
or 2T2R mode, two
represents the east NO YES No None
groups of the
Indicates
longitude.
parameters mustofbe
cabinet number
specified
the RRU wherefor the NO YES No None
Indicates
antenna port
antenna the 1When
port. is
subrack
the antenna
located. number is in of
the
2T4R RRU where
or 4T4R NO YES No None
antenna
mode, four
Indicates port
the 1
groupsis
slot
located.
of parameters
number of the must
RRU
NO YES No None
be specified
where antenna for port
the
antenna
1 port.
the When
is located.
Indicates
the antenna
number is in
of antenna NO YES No None
Indicates
8T8R
port 1.mode, the eight
cabinet
groups of number of
the RRU where
parameters must be NO NO No None
Indicates
antenna
specifiedportthethe
for 2 is
subrack
located. number
antenna port. of
the RRU where NO NO No None
antenna port
Indicates the 2 is
slot
located. of the RRU
number
NO NO No None
where antenna port
2 is located.
Indicates the
number of antenna NO NO No None
Indicates
port 2. the
cabinet number of
the RRU where NO NO No None
Indicates
antenna port the 3 is
subrack
located. number of
the RRU where NO NO No None
antenna port
Indicates the 3 is
slot
located. of the RRU
number
NO NO No None
where antenna port
3 is located.
Indicates the
number of antenna NO NO No None
Indicates
port 3. the
cabinet number of
the RRU where NO NO No None
Indicates
antenna port the 4 is
subrack
located. number of
the RRU where NO NO No None
antenna port
Indicates the 4 is
slot
located. of the RRU
number
NO NO No None
where antenna port
4 is located.
Indicates the
number of antenna NO NO No None
Indicates
port 4. the
cabinet number of
the RRU where NO NO No None
Indicates
antenna port the 5 is
subrack
located. number of
the RRU where NO NO No None
antenna port 5 is
located.
Indicates the slot
number of the RRU
NO NO No None
where antenna port
5 is located.
Indicates the
number of antenna NO NO No None
Indicates
port 5. the
cabinet number of
the RRU where NO NO No None
Indicates
antenna port the 6 is
subrack
located. number of
the RRU where NO NO No None
antenna
Indicatesport the 6 is
slot
located.
number of the RRU
NO NO No None
where antenna port
6 is located.
Indicates the
number of antenna NO NO No None
Indicates
port 6. the
cabinet number of
the RRU where NO NO No None
Indicates
antenna port the 7 is
subrack
located. number of
the RRU where NO NO No None
antenna
Indicatesport the 7 is
slot
located.
number of the RRU
NO NO No None
where antenna port
7 is located.
Indicates the
number of antenna NO NO No None
Indicates
port 7. the
cabinet number of
the RRU where NO NO No None
Indicates
antenna port the 8 is
subrack
located. number of
the RRU where NO NO No None
antenna
Indicatesport the 8 is
slot
located.
number of the RRU
NO NO No None
where antenna port
8 is located.
Indicates the
number of
altitude
Indicates oftheantenna
the MIMO NO NO No None
port
mode8.of
sector in the
the sector.
WGS
84
It isco-ordinate
the common
system. When the NO NO No LOFD-001038
MIMO mode
Indicates the or sector
value is
mutual-aid greater
name, which is a MIMO
than
string0,ofthe
mode. a sector is NO YES No None
above
maximum the of ellipsoid
30
Indicates
surface inthethelength
WGS
characters.
of
84semi-major
co-ordinateaxis NO YES No None
of the uncertainty
system. Whenlength the
Indicates
area ofisthe thesector.
value
of semi-minor less than
axis0,
orientation
The smaller of major
the
of sector
the is the
uncertainty below NO NO No None
axis of the value is,
parameter
the
area ellipsoid
of thethe surface
sector.
uncertainty
the higher area of
in
The the WGS
smaller 84
theco- NO NO No None
the sector
positioning
Indicates (the
the
ordinate
parameter system.
value is,
counter-clockwise
accuracy
estimated is.
altitude
For
the details,
higher thesee the
angle
of in degrees
the uncertainty
23.032
positioning
Indicates and the 36.455 NO NO No None
between
area of the the majorin
sector
protocols.
accuracy
confidence is.
axisWGS
the and north).84level by
co- The
which
smaller the
ordinate the position
system. NO NO No None
of
The the
parameter sector
smaller to be
value
the is,
included
the higher
Indicates within
the
the
parameter value is, the
uncertainty
positioning
combination
the higher the area.
mode NO NO No None
The
of thesmaller
accuracy
positioningsector,is. the
parameter
including
accuracy the is.value is,
the higher themode NO NO No None
combination
positioning
of multiple RRUs
accuracy
and the mode is. of a
single RRU.
Indicates the format
of geographical NO NO No None
Indicates
coordinates.
Indicates the
the range
maximum
of RX channel output
latitude of the
power
frequenciesof the sector. NO YES No None
sector in the WGS-
If a sector
Indicates
supported is
the
by range
the
84 coordinates.
configured
of TX channel
longitude
sector. This ofwith
the two
RRUs,
frequencies the NO YES No None
sector in
parameter theis WGS-
set to
maximum
supported
84
the coordinates.
Indicates
frequency output
by flag
the the
band of
power
sector. of
This the
the omnidirectional
between the sector NO NO No None
is the larger
parameter
cell.
minimum is set to
and
maximum
the frequency
maximum output band
power
between
frequencieson the
the TX
on thea NO NO Yes None
Indicates
channel
minimum ofwhether
theoftwo
and
RX channels
license theto
RRUs.
maximum
RRU Ifisagranted
where sector
the is
a sector. A license
configured
frequencies with
on one
the NO NO Yes LBFD-004014
antenna
is required portsonly areby
RRU,
TX theIf maximum
channels
located. of the
a sector
a
RRUdual-mode
output powerthe
where sector.
of the
is configured with NO NO Yes None
sector
antenna is
two RRUs, theare the
ports
maximum
located.
frequency If output
a
bandsector
power
is on
supported by with
configured the TX
the NO NO Yes None
channel
two
Indicates
sector is of
RRUs, the
the
the the
RRU.
frequency
cabinet
intersection band
number of of
supported by YES NO No None
the optical bands
frequency or the
Indicates
sector
electrical is the the
module.
supported by the
subrack
intersection number of
two RRUs. Ifofa YES YES No None
the optical bands
frequency or
sector
Indicates is configured
the slot
electrical module.
supported by the
with
number ofone
only theRRU,
two
the RRUs.
frequency If aband YES YES No None
optical or electrical
sector
Indicates is configured
the
of the sector is the
module.
with
number onlyofone
frequency theRRU,
band
the frequency band YES YES No None
optical
supported or electrical
by the
Indicates
of the
module.
RRU. sector whether
is the
the optical band
frequency or
NO NO Yes None
electrical
supportedmodule
Indicates the is
by optical
the
in
RRU.
or position.
electrical module
type, which can be NO NO Yes None
SFP,
IndicatesESFP, theor
ELEC_SFP.
manufacturer of the
Indicates NO NO Yes None
optical or the electrical
transmission
module. mode
of the optical
NO NO Yes None
module, which can
be single-mode
Indicates or
Indicates the the
multi-mode. of the
wavelength NO NO Yes None
maximum distance
optical
Indicates
that signalsmodule.
thefrom
Indicates
the opticalthe
transmission code
module
maximum NO NO Yes None
can of the distance
rate travel opticala or
along
that signals
electrical
single-mode from
module.
optical
Indicates
the optical the
module
fiber
maximum with a 9- NO NO Yes None
can travel distance
micrometer along a
that signals core
single-mode from
optical
diameter.
Indicates
the optical The
the
modulevalue
fiber
0 with
indicates
maximum a 9-
that
distance the NO NO Yes None
can travel
micrometer along
core a
optical
that module
signals
multi-mode from does
optical
diameter.
not
the support
optical The thisvalue
fiber
0 with amodule
indicates 50-
that the NO NO Yes None
type
can of optical
travel
micrometer along
corefiber.
a
optical
multi-mode module does
optical
Indicates
diameter. the
The
not
fiber support
with a that thisvalue
62.5- NO NO Yes None
observed
0 indicates the
type of
micrometer optical corefiber.
temperature
optical module of does
the
diameter.
optical
not support The
module. thisvalue
This
0 indicates that the NO NO Yes None
parameter
type of opticalvalidis fiber.
optical
only whenmodule the does
not support
optical module thistype
type
is ESFP.of optical fiber.
Indicates the
observed voltage of
the optical module.
Indicates
This parameter the is NO NO Yes None
observed
valid only current when the of
the optical
optical module module.
Indicates
This parameter the TXtype is NO NO Yes None
is ESFP.
optical power of the the
valid only when
optical
optical module.
module This
type
Indicates
parameter the RX
is valid NO NO Yes None
is ESFP.
optical
only when theof the
power
optical
optical module.
module type This
parameter
is ESFP. is valid NO NO Yes None
only whenthe
Indicates the
optical
transmission type
module
Indicates
is ESFP. of the NO NO Yes None
distance
Indicates the the
current
electrical VSWRmodule. of
cabinet number
the TX channel.The of
the
value RRU where
of this the YES NO No None
Indicates
TX channel theisfield
logical
may
subrack
switch beofdisplayed
number
the TX of
located.
as
theNULL
Indicates
RRU This
channel. in
theone
where actual of
the YES YES No None
the following
physical
TX channel is status toof
switch
Indicates theisslot
used
situations:
the TXorchannel.
located.
open close
number of the the RRU
(1)
The
TX The
logical
channel. switch YES YES No None
where the TX
ALMPROCSW
of
Thisthe TX
switch channel
and the
channel isthe
Indicates located.
parameter
and
eARFCN the ARFCN onis the
set on to
number
ON and of
a the TXTX
major YES YES No None
the TX channel
channel determine
channel.
VSWR alarm has
determine
the state ofthe the state
been
of the reported;
physical
physical switch of NO NO No None
(2)
the The
switchTX of current
the TX
channel:
output
channel:
When this power
Whenswitchof thetheis
Indicates
RRU
logical is 15 the
dB less NO NO Yes None
ON andswitch the TXof a
distance
than
TX the is
channel from
maximumis the
ON
channel
current
output
and the positions
power;
TX channel of
configured with NO NO Yes None
VSWRs
(3)
is that
The current
configured are time
eARFCNs, thewith
generated
is within two
ARFCNs, on the
the
physical switch is
TX branch
minutes
physical away to the
switch fromof
ON. In the other NO NO Yes None
antenna
the timethe
Indicates
the TX port
when
the
channel on theistop
cases, physical
of
RRU theInwas
maximum
ON. BSothercabinet.
powered
outputcases,
switch is OFF.
To
on query
power
the or onthe
reset,
physical theswitch
TX NO NO Yes None
parameter,
because
channel.
is OFF. The therun
The TX the
error
Indicates
DSP
periodic
is VSWR the
detection
channel is shut W.
precise to +/-1
number
command.
of the when of the BITS
standing YES NO No None
down
Indicates thea
clock
wave link.
number ofnot
VSWR hasalarm thebeen
started
cabinet wherecase;
(major) in
or this
a the NO NO No None
(4) The
Indicates
temperature
BITS clockspecified
the alarm
link is
TX
numberchannel
(major)
configured. of the
for does RF
not exist.
subrack
units where the
is generated. NO NO No None
Indicates
BITS clockthe link is
number
Indicates
configured. ofthethe slot
where
activation
Indicates thethe BITS of
status NO NO No None
clock
the BITS link clock
availability isof a link.
configured.
If the clock
BITS link is link.active,
Indicates the link NO NO Yes None
the
OnlyBITS clock
an available
priority
is the link
clock of can
currentthe clock
serve
source.
source The
of
as the current thevalue clock1 NO NO Yes None
indicates that the
system. Otherwise,
source.
current
the clock clock
link source
has the highest
cannot be locked NO NO No None
priority,
even if itand
Indicates isthethe
value
number 4
activated. theindicates
of
that theline current YES NO No None
E1/T1
Indicates clock
the
clock
link.
number source
of thehas
the lowest
cabinet where priority.
the NO NO No None
E1/T1 line clock link
is configured.
Indicates the
number of the
subrack where the NO NO No None
Indicates
E1/T1 linethe clock link
number
is configured. of the slot
where the E1/T1 NO NO No None
Indicates
line clock the link is
number
Indicates
configured. ofthe the port
Indicates
where the the
activation status of E1/T1 NO NO No None
availability
line E1/T1
the clock link of the
line isclock
E1/T1
configured.
link. line link
If the clock is
link. Only
Indicates an NO NO Yes None
active, thethe E1/T1
available
priority
line clock of clock
the
link clockislink
the
can
source. serve The
current clock source as the
value 1 NO NO Yes None
current
indicates
of the system.clock
that the
source.
current clock Otherwise, source
the clock
has the highest link NO NO No None
cannot be
priority, and locked
Indicates
Indicates thethe
isthe
even if4itindicates
value
activation
Indicates
number status
ofthe the peer of YES NO No MRFD-231601
activated.
that the current
the peer
availability
reference reference
of thelink.
clock
clock
Indicates source
link.the
clockreference If thehaslink
peer
the
number lowest
is active, of priority.
a TOD
clock
Indicates link.the Only
the
peer an NO NO Yes None
clock
reference
available link.clock Thetype
clock link
link
of a TODofclock
number the link.
TOD
is
can the current
serve as clock
the
It indicates
clock link mustwhether NO NO Yes None
source
current of
clock the
the corresponding
correspond to the
system. Otherwise,
source.
TOD
number portofisthe anTOD input
the
or clock link
output port. An YES NO No None
port
cannot on be the USCUb.
input
For port islocked
example, usedclockto
even
input if it is signals
clock
link No.0
activated. NO NO No None
to the BS,the
Indicates
corresponds and toan port
output
number
No.0, clock port
of the is
linkused
to
No.1 provide
cabinet where
corresponds clockthe NO NO No None
Indicates
signals
TOD clockfor theother
link is
to port No.1.
number
BSs. Only
configured. of the TOD
subrack
Indicates
clock of input where
the length the
type NO NO No None
Indicates
TOD clock thelink
of
canthe TOD
serve as a is
feeder.
number
configured.
The of the slotis
clockfeeder
source. delay
where the
calculated on the TOD NO NO No None
clock
basis link
of the is
Indicates
configured. theTOD cable
feeder
type of lengththe TOD to NO NO No None
ensure
feeder. the clock
accuracy. the
Indicates The clock
accuracy
activation
Indicates the is affected
status of NO NO No None
ifavailability
a there
TOD clock is an oflink.
an If
excessively
the link
TOD clock is active,large
link.
difference (about NO NO Yes None
the TOD
Only an availableclock link20
m)
is between
the current
clock link the the
canfeederclock
serve
Indicates
value
source
as the ofcurrent
ofthistheTOD clock NO NO Yes None
delay of
Indicates the the
parameter
system.
source. and the
Otherwise,
clock link.
priority of If the
the clock
actual
the clockfeederlinkvalue
feeder
source. delay
The is not 1
length.
cannot be locked NO NO Yes None
supported
indicates that by the the
even
satellite
current if itclock
is source
card, this
activated.
parameter
has the highest is set to NO NO No None
NULL. and the
priority,
Indicates
value 4 indicates the
number
that of
the current the GPS YES NO No None
Indicates
clock link. the
clock
cabinet source
number hasof
the lowest
the board where the priority. NO NO No None
Indicates
satellite card the is
subrack
attached. number of
the board where the NO NO No None
satellite card is
attached.
obtained position
information is used
as the tracing
result. When the
specified duration is
shorter
Indicates than the1slot hour,
the
number position
of the
information
board where the NO NO No None
obtained
satellite mayisfail to
card
Indicates
meet the the
precision
attached.
longitude of the
requirement or the NO NO No None
GPS
tracing antenna.
may even A
negative
Indicates
fail if the GPS value
the
indicates
latitude
signals are ofthe the
weakwest
GPS or NO NO No None
Indicates
longitude,
antenna. Athe
and a
negative
there is a
altitude
positive
value of
value
indicates the GPS the
interference NO NO No None
antenna.
indicates
south Athe
latitude, negative
east
and
sources. Therefore,
value
longitude.
a indicates
positive valuethat
you are advised to
the GPS
indicates antenna northis
specify a the duration NO NO No None
below
Indicates
latitude. thethe sea level,
of longer than 3
and
antenna a positive
angle, value
hours for the
indicates
which that the NO NO No None
tracing.is the
Indicates theangledelay
GPS
with
of antenna
thetheGPShorizontal is
feeder.
SEARCH_WITH_P
above
line.
Some satellite level.
the sea
RECISION NO NO Yes None
cards
indicates do not that the
Indicates
support
tracing isqueryingthe
performed of
duration
this
based for
information.
on the tracing
Indicates the length NO NO No None
the position
Indicates
specified of the
thefeeder.
precision.
of the GPS
GPStracing
precisionsatellite. is
The feeder delay is
requirement
terminated
calculated for
when
on the NO NO No None
Indicates
tracing the the type
the
basis
of the GPStheposition
calculated
of GPS
feeder,
of the GPS
precision
feeder lengthin satellite.
the to
which can be the NO NO No None
horizontal
increase
twisted-pair theorcable
vertical
clock or
direction
accuracy.
coaxial cable. meets
The clock the
precision is affected
accuracy NO NO No None
Indicates
there is whether
ifrequirement, an and
the
the position
obtainedlarge
excessively of the
GPS
position satellite
difference (noisless
information NO NO Yes None
Indicates
locked by whether
the GPS
is used
than 20 as
m) the
between
the calendar
reference receiver.
tracing
the value result.
of of this
information the NO NO Yes None
AUTO_SEARCH
parameter
GPS reference the
Indicates and
whether
indicates
actual
the GPS feeder that the
receiver
Indicates issatellite
thevalid.
position
Indicates
length. the
positioned information
by the NO NO Yes None
working
Indicates mode
is automatically whether of a
physical
GPS status
reference of
satellite
the
calculated receiver.
position by of the
the
the satellite
receiver is card,
valid.
Satellite
GPS
GPS satellite receivers NO NO Yes None
which can be is set
antenna
are
on
based classified
the on
Indicates GPS the into
the clock
NOTEXIST
dual-mode
reference
received satellite
adjusting satellite
receiver.
state of
(Inexistent),
receivers and NO NO Yes None
signals.
the GPS reference
ANTENNASHORTE
single-mode
Indicates
receiver. whether
D (Antenna
satellite
the clock receivers.
mode of A
Shorted), NO NO Yes None
dual-mode
the GPS
Indicates the satellite
reference
ANTENNAOPENE
receiver
number supports
is valid.
of
D (Antenna
three
Indicates
GLONASS satellite
the NO NO Yes None
Opened),
tracing
physical
satellites modes.
type
that of
areFor
the
SELF_CHECK_FAI
example,
satellite
traced. the which
card,
LURE (Self-check
working
can mode of
be M12M, UT,a NO NO Yes None
Failure),
GPS/GLONASS
RT, K161, GG16,
COMEXCEPTION
satellite
JNS100, receiver
RGPS,
(COM Port NO NO Yes None
can
CWAIN, be GPS RTSMT, active,
Communication
GLONASS
UBLOX5,
Indicates active,
BD7702,
the
Fault), NORMAL
or both. In detected
NAVIOR, GPS
(Normal),ofPPSTOD,
number NO NO Yes None
active
M1000,
GPS mode,
TRGPS,
satellites. the
UNKNOWN
satellite
BD7702CMS, receiver or
(Unknown
preferentially
OEM4. NO NO No None
Exception),
processes
Indicates theGPS
USCUINVALID
signals.
number In
of detected
(USCU Invalid), or NO NO Yes None
GLONASS active
COMPASS
UNKNOWN_STAR
mode, the satellite
satellites.
_CARD (Unknown
receiver
Star Card).
preferentially
processes
GLONASS signals.
In GPS and
GLONASS both
between the Time
Server and BS.
When the Boundary
clock or
Indicates
Transparent theclock is
activation
protocol
Indicates
not supported type status
the ofontheof
the
IP GPS
clock,
priority
the transportof clock
which
the link.
can
clock
If
be the
IEEE
source.
network, linkThe is active,
1588
this V2 1
value NO NO Yes None
the GPS
(PTP)
indicates
parameter clock
or Huawei
thecan link be
is the
to current
proprietary
current
set E2E clock only. clock
protocol.
source
source
IEEE
has the
When 1588of
the the
highest V2,
Boundary NO NO No None
system.
defined
priority,
clock or by
and thethe
Indicates
IEEE,
value 4supportsthe
indicates
Transparent clock both is
number
phase
the current
supported of on the
clock IP
the YES NO No None
clock
sourcelink.
synchronization
transport has the and
network,
frequency
lowest
this priority. is
parameter LOFD-00301302
NO NO No
synchronization.
Indicates
set to P2P.the There LOFD-00301303
Huawei
number proprietary
of the
are two application
protocol,
cabinet
modes whichthe
where
for is NO NO No None
Indicates
the Huawei-defined
IP clock
IEEE1588 the
link V2:is the
number
IP clock of
configured.
Point-to-Point the mode
protocol, is
subrack
applicable
(P2P) and End-to-where to the the NO NO No None
IP clock
interconnection
Indicates
End mode link
the is
(E2E).
configured.
between
number
The ofHuawei
Point-to-Point the slot
NO NO No None
equipment
where the
mode, alsoIP and clock
known
supports
link is
Indicates
as frequency
configured.
the full-the client
synchronization LOFD-00301302
IP addressmode,
supported of the IP NO NO No
only. LOFD-00301303
clock
involves
Indicates link.all the clock
Indicates
nodes: the the OC, serverBC,
domain
Indicates
IP address to which
the of thethe IP NO NO No LOFD-00301302
and
IP TC.
clock
priority This
link
configured mode
clock
requires link. that the
belongs.
by the user The for the
Boundary
Indicates
setting
BMC of
(Best clock
the
thisMaster or NO NO No LOFD-00301302
Indicates
Transparent
priority whether
configured clock
parameter
Clock)
the BMC algorithm.must be
should
by
the
The the
same be(Best
user
information as for
the the
Master
Indicates
supported
BMC Clock)
(Best the
by all
Master NO NO No None
setting
about
algorithm
priority of
the the
priority
is
configured clock
network
Clock)
server.
can beuser devices
algorithm.
collected
enabled
by the
between
The or
informationthe not.
for
Time ON
the
from
Indicates
indicates
BMC the
(Best Time
the
that the
Master NO NO No None
Server
about
Server.
priority and
the This Time
priority
configured
BMC
Clock)
Client.
can bealgorithm
algorithm.
The
collected delay is
parameter
by the
enabled,
The user
informationand specifies
forOFF the
variation
from
the
BMC the
clock
(Best of
Time time
quality
Master NO NO No None
indicates
about
stamp
Server. the
is This that
priority the
that
Clock)
BMC isalgorithm
anticipated
algorithm.
can
by
The the
be
compensated
parameter collected
user.
information byis
specifies
The
disabled.
from
the the
Boundary
clock Time
quality clock NO NO No None
Time
about
Server. Server
the This with
priority
or
that
the
can Transparent
is anticipated
matching
be collected clock
parameter
clock,
by thetheso
user. the specifies
The
quality
from
the clock is Time
selected
quality NO NO No None
frequency
Time
as the
Server. Server and
This with
target time
server.
that
of
the the is BS
anticipated
matching can be
clock
Class0
parameter
by hasspecifies
the recovered.
user. the
The In
easily
quality
highest
the clock ispriority,
selected
quality and NO NO No None
Time
End-to-End
as the Server
target with
mode,
server.
Class0
that
the to Class3
is anticipated
matching clock
the
Class0time
Indicates
indicate
by the has
user.stamp
thetheTheis in
priorities
quality
Indicates
transmitted
highest
current is selected
thefrom
priority,
priority the
and
class NO NO Yes None
descending
Time
as theServer
Indicates
activation target the order.
with
statusserver. of
Time
Class0
of
the the Server
IP
matching
availability to Class3
clock to BS
link.
clock
oflink.
the
Class0
the
by IP clock
means
indicate has ofthe
priorities IfIP
in
quality
clock
highest
the is
link.
IP clock selected
Only
priority, link andan
is NO NO Yes None
network
descending
as the
available devices,
target clock order.
server.
link
Class0
active,
but the itto
timeisClass3
the
stamp
Class0
can
indicate
current serve has asthe
priorities
clock the in
source
is not
highest
current processed
priority,
clock by
and NO NO Yes None
descending
of
the the system.
network order.
Class0 to
source. Class3
Otherwise,
devices.
Indicates
indicate
the Asthea result,
clockpriorities
link in
the delay
networking
descending
cannot bevariationtype
order.
locked for NO NO No LOFD-00301302
of
the
eventime itstamp
IPifclock.
Indicates isthe
received
activated.by thefor
compensation BS
is not compensated NO NO No LOFD-00301301
asymmetry of IP
Indicates
and
clockthe links. the step
clock needs
mode, which canby
to be recovered be
NO NO Yes None
ONE_STEP
using an adaptive or
Indicates
algorithm.the
TWO_STEP. self-
In this
acquired
case, there is noIDVLAN
NO NO Yes None
of
needthefor IP the clock
server.
network devices to
support the
Boundary clock,
Transparent clock,
or IEEE1588 V2.
Indicates
Indicates the the IEEE
1588
Indicates
priority V2ofprofile
the
the offset
clock
supported
of the Universal
source. The byvalue
the IP1
Indicates
clock link, the
which NO NO Yes None
Time Coordinated
indicates that the
priority
can
(UTC). be of the the ITU-TIP
current clock source
clock
G.8265.1 server. or The
IEEE
has the highest NO NO No None
value
Indicates
1588 V20 indicate
thethe the
protocol.
priority, and
highest
sending
ITU-T priority,
frequency and
value 4 indicatesis
G.8265.1
the
of valueby255
ANNOUNCE
defined NO NO No None
that the current
indicates
packets
International
Indicates atthe
the lowest
thehas BS
clock source
priority.If
side. two IP
Telecommunication
sending frequency
the lowest priority. NO NO No None
clock
Union
of SYNC servers
(ITU) packetsforare theat
required,
the BS side. value
frequency the
of this parameterofis
synchronization NO NO No None
used
an IEEEto identify
1588 V2 theIP
Indicates
active
clock link andan interval
standby
with the
of
IP negotiations
clock servers.
networking type of NO NO No None
between
The IP clock
UNICAST. the BS
server
If the IP
and
with IP
clock alink clock
higher compliesserver.
priority
Indicates
After the the NO NO No None
serves
with ITU-T asinterval
the active
number
elapses, of
the theBS
server
G.8265.1, and theIP
the IP
synchronous-
initiate another
clock
clock server
server with a
Ethernet
Indicates
negotiation clock
thewith link.
the YES NO No None
lower priority
supports the serves
Currently,
number
server. ofonlythe one
as the standby
interconnection with
link (link
cabinet No.0)
where the can
server.
servers
Indicates of other
the NO NO No None
be configured.
synchronous-
vendors.ofIf the
number the IP
Ethernet clock link
clock linkwhere
subrack complies the
is configured.
Indicates NO NO No None
with IEEEthe
synchronous- 1588 V2,
number
the IP clock
Ethernet ofclock
the slot
serverlink
where
does
is notthe
configured. support
Indicates the NO NO No None
synchronous-
the interconnection
Indicates whether
number
Ethernet
with servers of
clockthe ofport
link
handling
where the of SSM
is configured.
other
frames vendors.
is NO NO No None
synchronous-
Indicates the
supported.
Ethernet clock link
activation
SSM: status of
is
a configured.
Indicates
synchronous- the NO NO No None
Synchronization
availability of a link.
Ethernet
Status clock
Message
synchronous-
If the link is active,
Recommendation
Ethernet clock NO NO Yes LOFD-00301301
Indicates
the synchronous-the link.
ITU-T
Only anofavailable
priority
Ethernet the clock
clock link
G.8264/Y.1364
clock link can serve1
source.
is the currentvalue
The clock NO NO Yes LBFD-00300501
Indicates
as the current the the
indicates
source the clock
of that
availability
source.
current clock of source
Otherwise, the
system.
clock
the source.
clock
has the highest link Only NO NO No None
an available
cannot
priority, be
andlocked clock
the
link
evencan
value serve
if4itindicates
is as
Indicates
the current whether
clock a NO NO Yes None
activated.
that the
Indicates current
the is
clock
source. source
Otherwise,
clock
priority
licensed source
of tothe behasclock
used.
the
the clock
lowest
source.
Indicates Thelink
thepriority.
value 1
Only
cannot a licensed
be locked NO NO Yes None
indicates
working
clock source thatcan
mode the
of
even
current
the if itclock
system is source
serve
activated. as theclock. current
has
clockthe
Manual highest
indicates
source. NO NO Yes None
priority,
that a clock
Indicates and the
thesource
clock
value
must
link be4 indicates
number specifiedof the
that
by theuser.
the current Auto NO NO No None
reference clock
clock
indicatessource
Indicates that
source. the has the
type
the
systemlowest
of the user-selected priority. NO NO No MRFD-231601
automatically
Indicates
clock source. the clock
selects a clock
synchronization
sourceofbased
mode a BS,on NO NO No LBFD-004006
the
which priority
can be and
availability
frequency of the
clock source. Free NO NO No None
synchronization or
indicates that the
phase
system clock works
synchronization
in free-running
(also known as time
mode, that is, the
synchronization).
system clock does
not trace any
reference clock
Indicates the status
of the current clock
source,
Indicateswhich the can
be Normal,
working mode Lost, of
Unavailable,
Indicates
the clock. the Jitter,
It also NO NO Yes None
Frequency
negotiation
indicates state of
whether
Deviation,
the Common
system clock Public is
Phaseoutscope,
Radio
stable.Interface
The working or NO NO Yes None
Inconsistent
(CPRI),
mode
Indicates ofwhich
the Clock
theclock can
References.
be
can NOTREADY(Not
be
Indicates the
negotiation Fastthestateclock at
Indicates clock NO NO Yes None
ready),
tracking,
source
the inLocked,
tail level
of use.
theof the
quality
NEGOTIATING(Ne
Holdover,
Common or Free
Public
BS. The clock
gotiating),
running.
Radio Interface
quality level has a NO NO No None
NEGOTIATED(Neg
(CPRI)
negativering, which
correlation
otiated),
can be or
with
Indicates
Indicatesthe clock
the ID of
the
TIMEOUT(Timeout)
NOTREADY(Not YES NO No None
quality.
the
currentRRU chain/ring.
Common
.ready),
NOTREADY(Not
Public Radio
ready) indicates
NEGOTIATING(Ne
Interface
that the (CPRI)
rate NO NO Yes None
gotiating),
line rate at the
negotiation hashead not
NEGOTIATED(Neg
of
beenthe
Indicates RRU
started.
the
otiated), or NO NO Yes None
chain/ring.
NEGOTIATING(Ne
current Common
TIMEOUT(Timeout)
gotiating)
.Public Radio
NOTREADY(Not indicates
that
ready)the
Interface rate
(CPRI)
indicates is NO NO Yes None
being
line negotiated.
that the rate tail
rate at the
NEGOTIATED(Neg
of the RRU has not
negotiation
otiated)
chain/ring. indicates NO NO Yes None
been started.
that the rate
NEGOTIATING(Ne
negotiation
Indicates
gotiating) the is
indicates NO NO Yes None
complete.
cabinet
Indicates number.
the
that the rate is
TIMEOUT(Timeout)
number
being of an RRU
negotiated.
Indicates
indicates
carried on the
that
the theRRU
NEGOTIATED(Neg NO NO Yes None
subrack
rate number.
negotiation
chain/ring. The
otiated)
Indicates indicates
the
timed
RRUs
that the
Indicatesout
areratedueslot
the to a
maximum
software
numbered or rate
from at0 in NO NO Yes None
negotiation
number.
the Common is Public
hardware
ascending
complete. fault
order. If
Radio
during
the RRU Interface
the chain is
TIMEOUT(Timeout)
(CPRI) port.If the NO NO Yes None
negotiation.
connected
indicates thatto the
the
maximum
ports located lineon ratethe
rate
is negotiation
NULL, the RF
baseband
timed out NO NO Yes None
module
processing ordue to a
boards,
software
Indicates
baseband or
the power
interface
the first port
hardware
consumption fault is the
board
head does
of the not
chain, NO NO No None
during
Indicates
support the
measurement thewhether point
and the
negotiation.
of the BS.last lineportrateis
the PSU
negotiation, intelligent
or the
the tail of the chain.
shutdown switch in
line rate negotiation NO NO No None
a BS is enabled or
fails.
disabled.
Indicates the
YES YES No None
cabinet number.
Indicates the
NO NO No None
cabinet type.
Indicates a brief
description, such as
function and NO YES No None
location, of the
cabinet.
Indicates the
NO NO Yes None
cabinet type.
Indicates the
cabinet number of YES YES No None
the subrack.
Indicates the
number of the YES YES No None
subrack.
Indicates the type
NO YES No None
of the subrack.
Indicates a brief
Indicates
description, thesuch as
physical
function and operation NO YES No None
status
location, of of
thetheboard,
Indicates
which can the
be type
subrack.
operational
of power supply
Uninstalled, statetoof NO NO Yes None
Indicates
the board,
subrack.
Starting the
up, alarm
which
Normal,
status.
can be For set to
Inconsistent, details
about
Enabled theordefinition
Unconfigured, NO NO Yes LBFD-004006
of Alarm
Disabled.
Power off, Status,
Enabled
Fault,
see ITU-T
indicates
Communication X.731.
that
Indicates theorbe
E-the NO NO Yes None
services
lost, In test,can
label,
carrieda on
combination textthefile
of with
a maximum
board.
various Disabled
states.of 2For NO NO Yes LBFD-004012
KB. It
indicatesis used
that
example, if a board to
no
record
service the
can
is not configured be
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates such
the type
the main control as
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
physical
the bar
module.
operation
code of the status
boardof NO NO Yes None
Indicates the
the
or theboard isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.the board
by the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU or DSP the of
result
the NO NO Yes None
of the operation.
board. The service
types of the DSP
consist of uplink NO NO Yes None
and downlink
services. The
Indicates the type
service types of the NO NO Yes None
of the device.
CPU consist of
Indicates
Master and theSlave.
Office
NO NO Yes None
name of the BS.
Indicates the
software version of NO NO Yes None
the board.
Indicates the
hardware version of NO NO Yes None
the board.
Frequencies
Band3: Common
Channel Number:
Frequencies
none
Channel Offset: Number: 0
Band4: Common
[937-1288] Offset:
Frequencies
1525 Special
Channel Number:
Frequencies
[1537-1738]
Channel Number:Offset:
Indicates
1805
none Special
Offset: the 0
BootROM
Frequencies
Band4: Common version NO NO Yes None
of the
Channel board.
Frequencies Number:
(1887,
Indicates
Channel 1912, the 1937,
Number: test
1962, NO NO Yes None
time. 1987, 2012,
[1312-1513] Offset:
2037, 2062, 2087)
1450 Special
Indicates
Offset:
Frequencies1735.1the test
NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762, Number:
1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Indicates
Channel Number:
Frequencies the
number
Indicates
(1007, 1012,
Channel of the1032,
the
Number: YES NO No None
cabinet
communication
1037, where
1062,
[4132-4233] 1087)the
Offset:
Indicates
EMU
address is the
located.
of the
Offset:
0 670.1
Specialof the
number
EMU, which is
Band6:
Frequencies Common YES NO No None
subrack
determined where by the the
Frequencies
Channel
Indicates Number:
the
EMU
settingsis located.
of the 4-bit
Channel
(782,
number 787,
Indicates ofNumber:
807,slot
the
the
dual in-line
[4387-4413] package
Offset: YES NO No None
812,
where 837,
the
cabinet number 862)
EMU is
of
(DIP)
0 switch
Special
Offset:
located. 670.1on the
the manager that
EMU. The
Frequencies
Band6: Common
manages
Indicates the EMU.
the NO NO No LBFD-004012
communication
Channel
Frequencies Number:
The manager
subrack number of the
of
address
(1037, is used by
Channel
EMU
the is1062)
manager. Number:
usually Offset:
Thea
the
670.1EMU to Offset:
BBU orBand7:
[4162-4188]
manager RRU.of the
NO NO No LBFD-004012
communicate
Common
0 Special
Indicates the with
EMU
the is
main
Frequencies usually
control a
Frequencies
number
BBU or of the serial
RRU.
and NO YES No LBFD-004012
port transmission
Channel
Channel
to which Number:
Number: the
board.
[2237-2563]
Indicates
(812,
EMU The
837)
is the value
Offset:
lower
Offset:
connected. of
this
2175
limit parameter
Special
670.1ofBand7:
temperature. must
NO NO No LBFD-004012
be consistent
Frequencies
When
Common the with
Indicates
the actual
Channel
temperature
Frequencies the upper
settings
Number:is
limit
of theofDIP
(2587,
below
Channel temperature.
2612,
the switch.
lower
Number: 2637, NO NO No LBFD-004012
When
The
2662,an
limit, the
4-bit
2687,
[2012-2338] DIP2712,
ALM-25650 switch
Offset:
temperature
can
2737, be treated
2762,
Temperature
2100 Special 2787, as a
Indicates
exceeds theupper
the lower NO NO No LBFD-004012
4-bit
2812, binary
Abnormal 2837,
Frequencies number.
2862,
alarm is
limit
limit, of
an humidity.
ALM-25650
The
2887, settings
reported.
Channel 2912) Number: of ON
Offset:
When the
Temperature humidity
and
2105.1OFF
Indicates
(2362, 2387, are
Band8:
the upper
2412,
is below the
Abnormal lower
alarm NO NO No LBFD-004012
represented
Common
limit
2437, of humidity.
2462, by 1is
2487,
limit, an ALM-25651
reported.
Indicates whether
and
2512, 0 respectively.
Frequencies
When theAbnormal
2537, humidity
2562,
Humidity
to allow the report
Convert
Channel
exceeds
2587, 2612,the
the 4-bit
Number:upper
2637, NO NO No LBFD-004012
alarm
of is reported.
a dedicated
number
[2937-3088]
limit,
2662, an
2687)fromOffset:
ALM-25651 binary
Offset:
Indicates
analog
to decimal, whether
alarm. andIf the
340
2030.1Special
Humidity Abnormal
Band8:
to allow
shield
then theflagthe report
for
decimal an NO NO No LBFD-004012
Frequencies
alarm
Common is reported.
of a
analog
numberdedicated
alarm
is used is as
Channel
Frequencies Number:
Boolean
enabled,
the value alarm.
the
of If
analog
this
none
Channel Offset: 0
the
alarmshieldNumber:flagbe for a NO NO No LBFD-004012
Band9:cannot
parameter.
[2712-2863] Common Offset:
Boolean
reported. alarm is
Frequencies
340
Indicates
Special the
enabled, the
Channeltemperature
Frequencies
current Number: NO NO Yes LBFD-004012
Boolean alarm
[9237-9387]
Channel
of Offset:
cannot beNumber:
the environment.
reported.
0 Special
none Offset:
Indicates the 0
Frequencies
Band9: NO NO Yes LBFD-004012
ambientCommon humidity.
Channel Number:
Indicates
Frequencies the -48 V
none voltage
input
Channel Offset: Number: 0. The
from
Indicates NO NO Yes LBFD-004012
the powerthe
frequency
[8762-8912] of Offset:
the
supply
current
local
cabinet.cellvalue
must be
0 Special
measured
the same asbythatthe of
Frequencies
Indicates the NO NO Yes LBFD-004012
external
the bearing sensorlogical that
Channel
current Number:
value
is connected
cell. to
none
measuredOffset: 0.
analog portby1.the NO NO Yes LBFD-004012
external sensor that
is connected to
analog port 2.
Indicates the
current
Indicates value
the
measured
physical by the
operation
Indicates the that NO NO Yes LBFD-004012
external
status of sensor
the board,
current
is connected
Indicates value to
which canthe be
measured
analog
operational portby 3.the of
state
Uninstalled, NO NO Yes LBFD-004006
external
Indicates
the board, sensor
the that
alarm
which
Starting up, Normal,
is connected
status. For
can be set to to
details
Inconsistent,
analog
about
Enabled port
the 4.
ordefinition NO NO Yes LBFD-004006
Unconfigured,
of Alarm
Disabled. Status,
Enabled
Power off, Fault,
see ITU-Tthat
indicates
Communication X.731.
Indicates the E-the NO NO Yes None
services
lost, In test, orbe
can
label,
carrieda on
combination textthefile
of with
a maximum
board.
various Disabled
states.of 2For NO NO Yes LBFD-004012
KB. It
indicatesis used
that
example, if a board to
no
record
service the
can
is not configured be
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates such
the type
the main control as
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
physical
the bar
module.
operation
code of the status
boardof NO NO Yes None
Indicates the
the
or theboard isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.the board
by the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU or DSP the of
result
the NO NO Yes None
of the operation.
board. The service
types of the DSP
consist of uplink NO NO Yes None
and downlink
services. The
Indicates the type
service types of the NO NO Yes None
of the device.
CPU consist of
Indicates
Master and theSlave.
Office
NO NO Yes None
name of the BS.
Indicates the
software version of NO NO Yes None
the board.
Indicates the
hardware version of NO NO Yes None
the board.
Frequencies
Band3: Common
Channel Number:
Frequencies
none
Channel Offset:
Number: 0
Band4: Common
[937-1288] Offset:
Frequencies
1525 Special
Channel Number:
Frequencies
[1537-1738]
Channel Number: Offset:
Indicates
1805
none Special
Offset:the 0
BootROM
Frequencies
Band4: Common version NO NO Yes None
of the
Channel board.
Frequencies Number:
(1887,
Indicates
Channel 1912, the 1937,
Number: test
1962, NO NO Yes None
time. 1987, 2012,
[1312-1513] Offset:
2037, 2062, 2087)
1450 Special
Indicates
Offset:
Frequencies the test
1735.1 NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762,Number: 1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Indicates
Channel Number:
Frequencies the
number
(1007, 1012,
Channel of the1032,
Number: YES NO No None
cabinet
1037, where
1062,
[4132-4233] the
1087)
Indicates
FMU is theOffset:
located.
Offset:
0 670.1
Specialof the
number
Band6:
Frequencies Common YES NO No None
subrack where the
Frequencies
Channel
Indicates Number:
the
FMU is located.
Channel
(782,
number 787,ofNumber:
807,slot
the
Indicates YES NO No None
[4387-4413]
812, 837,
where thethe 862)
FMU Offset:
is
cabinet
Offset: 670.1 of
0 Special
located. number
the manager.
Frequencies
Band6: Common The
Indicates thethe NO NO No LBFD-004012
manager
Channel Number:
Frequencies of
subrack
FMU
(1037,is1062) number
usually a of
Offset:
Channel
the manager. Number: The
BBU
670.1 orBand7:
[4162-4188] RRU.Offset: NO NO No LBFD-004012
Indicates
manager thethe
of
Common
0 Special
Indicates
communication the a
FMU is
Frequencies usually
Frequencies
number
address
BBU of
of
or RRU. the
the serial
Channel
Channel Number: NO YES No LBFD-004012
port where
FMU. TheNumber: the FMU
[2237-2563]
Indicates
(812,
is 837)whether
connected.
communication Offset:
Offset:
2175
to allow
670.1 Special
the
Band7:
address is used by report NO NO No LBFD-004012
Frequencies
of aFMU
Common
the dedicatedto
Channel
Boolean
Frequencies
communicate Number:
alarm. If
with
(2587,
the
Channel
Indicates 2612,
shield Number:
the main control 2637,
the ratioa
flag for NO NO No LBFD-004012
2662,
Boolean 2687,
[2012-2338]
of the alarm
current
and transmission 2712,
is
Offset:
2737,
enabled,
2100
rotation
board. 2762, the
Special
speed 2787,
of
2812,
Indicates NO NO Yes LBFD-004012
fan2837,
Boolean
Frequencies
the the
its 2862,
toalarm switch
Indicates
2887,
of smart
cannot 2912)
be
Channel Number:
maximum the Offset:
reported.
rotation
2105.1
temperature
(2362,
speed. 2387,Band8: at the
2412, NO NO Yes LBFD-004012
air
2437,outlet
Common
control. of the
When
2462, the
2487,
FMU.
Frequencies
smart
2512, temperature
Indicates 2537, the2562,
Channel
control
temperature
2587, 2612, isNumber:
enabled,
at the
2637, NO NO Yes LBFD-004012
the rotation
[2937-3088]
air speed
Offset:
Indicates the FMU.
2662,inlet
Indicates of
2687) the
the Offset:
of
340 the
2030.1
average fan
Special
Band8:is
rotation
physical operation NO NO Yes LBFD-004012
adjusted
Frequencies
Common
speed of by
the the
fan per
status of the board,
FMU
Channel according
Frequencies
minute.
Indicates Number:
the to
which can be
the
none temperature
Channel Offset:
operational Number: 0
state of
Uninstalled, NO NO No LBFD-004006
control
Band9:
[2712-2863]
Indicates
the board, parameters
Common
the Offset:
whichalarm
Starting up, Normal,
delivered
Frequencies
340
status.Special
For
can be set to by the
details
Inconsistent,
BBU.
Channel
Enabled When
Frequencies
about theorNumber: the
definition NO NO Yes LBFD-004006
Unconfigured,
smart
of Alarm
Disabled. temperature
[9237-9387]
Channel Status,
Number: Offset:
Enabled
Power off, Fault,
0
control
seeSpecial
none ITU-T
indicates is
Offset:disabled,
X.731.
that 0
Communication NO NO Yes None
Frequencies
the
Band9:rotation
Indicates
services thespeed
Common
can E-the
lost, In test, orbe
Channel
of the afan
Frequencies
label, Number:
text isthe
file
carried
combination on of with
none
adjusted
Channel
a maximum
board. Offset:
by the
Number:
Disabled 0.2The
of
various states. For NO NO Yes LBFD-004012
frequency
FMU It
indicatesautomatically
[8762-8912]
KB. is used of Offset:
that the
to
no
example, if a board
local
according
0 cell must
tobe thebe
is Special
record
service the
can
not configured
the
temperature.
same
Frequencies
manufacturing
carried as that of NO NO Yes None
and failsontothe
the bearing
Channel
information
board. Number:logical
about
communicate with
cell.
none
equipment
Indicates Offset:the 0.
suchtype as
the main control NO NO Yes None
the
of board,
the board.
and transmission sub-
board,
board, or theoptical
physical
module.
operation status of
the board is
Unconfigured,
Communication
lost.
Indicates the bar
code of the
Indicates theboard NO NO Yes None
The
or thedownlink
cabinet.
description and
about
uplink frequencies
the services and
of the local cell NO NO Yes None
functions provided
Indicates
must stay the
within
by the board or the the
manufacturing
same
cabinet. frequency date
NO NO Yes None
of the
band.
The board orand
downlink the
Indicates
cabinet.
Frequency(MHZ) the
uplink frequencies=
manufacturer
(Frequency of the
of the local cell NO NO Yes None
board
Channel or the
must stayNumber within the /
cabinet.
Indicates
5) + Offset the issue
Band1:
same frequency
number
Commonof the
band. NO NO Yes None
board.
Frequencies
Frequency(MHZ) =
Indicates
Channel
(Frequency Number:
the type
NO NO Yes None
of
[10562-10838]
a board.
Channel Number /
Offset:
5) + Offset0 Special
Band1:
Indicates
Frequencies the object
Common NO NO Yes None
number ofNumber:
Channel a board.
Frequencies
Indicates the object
none
Channel Offset:
type of a Number:
board,0
Band2:
[9612-9888] Common NO NO Yes None
which is CPUOffset: or
Frequencies
0 Special the
DSP.
Indicates
Channel Number:
Frequencies
temperature of a NO NO Yes None
[9662-9938]
Channel Offset:
board. Number:
0 Special
none Offset:
Indicates the 0
Frequencies
Band2:
temperature Common
Indicates
Channel theof the
Number:
NO NO Yes None
Frequencies
power
service amplifier.
type of the
(412,
Channel 437,
Indicates 462,
Number:
the result
CPU
487, or DSP of the NO NO Yes None
of the512,
[9262-9538]
board.
537,
operation.
The
562,
Offset:
service
587,
0 612, 637, 662,
Special
types
687) of the DSP
Offset: 1850.1
Frequencies
consist
Band3: of
Channel
uplink
Common
Number:
NO NO Yes None
and downlink
Frequencies
(12, 37, 62,
services. The 87, 112,
Indicates
Channel
137, 162, the type
Number:
187,
service
of the of212,
typesOffset:
device.
[1162-1513] the NO NO Yes None
237,
CPU 262,
consist 287)of
1575
Offset: Special
Indicates 1850.1
theSlave.
Office
Master
Frequenciesand NO NO Yes None
Band3:
name ofCommonthe BS.
Channel Number:
Frequencies
Indicates
none Offset:the 0
Channel
software Number:
version of NO NO Yes None
Band4:
[937-1288] CommonOffset:
the board.
Frequencies
1525 Special
Indicates the
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Offset:
Number:
Indicates
1805
none Special
Offset:the 0
BootROM
Frequencies
Band4: Common version NO NO Yes None
of the board.
Channel
Frequencies Number:
(1887,
Indicates
Channel 1912,
the 1937,
test
Number:
1962, NO NO Yes None
time. 1987, 2012,
[1312-1513] Offset:
2037, 2062, 2087)
1450 Special
Indicates
Offset:
Frequencies the test
1735.1 NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762,Number:
1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Indicates
Channel Number:
Frequencies the
number
(1007, 1012,
Channel of the1032,
Number: YES NO No None
cabinet
1037, where
1062,
[4132-4233] the
1087)
Indicates
TCU is theOffset:
located.
Offset:
0 670.1
Specialof the
number
Band6: Common
Frequencies YES NO No None
subrack where the
Frequencies
Channel Number:
TCU is located.
Channel
(782, 787, Number:
807,
[4387-4413]
812, 837, 862) Offset:
0 Special
Offset: 670.1
Frequencies
Band6: Common
Channel Number:
Frequencies
(1037, 1062)
Channel Offset:
Number:
670.1 Band7:Offset:
[4162-4188]
Indicates the
number of the slot
Indicates YES NO No None
where thethe TCU is
cabinet
located.number of
the manager. The
Indicates thethe NO NO No LBFD-004012
manager of
subrack
TCU is usually a of
number
the
BBUmanager.
or RRU. The NO NO No LBFD-004012
manager
Indicates of thethe
Indicates
TCU the
is usually a
communication
number of the serial
BBU
address or RRU.
ofthethe TCU. NO YES No LBFD-004012
Indicates
port where thelower
TCU
The communication
threshold
is connected. of the
address is used
temperature. by
If the
Indicates the upper NO NO No LBFD-004012
the TCUair
cabinet to outlet
threshold
communicate
temperature of theiswith
temperature.
lower than theIf the
the main control NO NO No LBFD-004012
cabinet airALM-
and transmission
value, the outlet
Indicates
temperature whetheris Air
board. Cabinet
25655
to allowthan
higher the thereport NO NO No LBFD-004012
Outlet
of Temperature
a dedicated
value, the ALM-
Unacceptable
Boolean
25655 alarm.isAir
Cabinet If
reported.
the shield flag for a NO NO No LBFD-004012
Outlet Temperature
Boolean
Unacceptable alarmisis
enabled,
reported. the
Indicates the
Boolean alarm NO NO No LBFD-004012
number of
Indicates heaters.
whether
cannot
the low be noise reported.
mode
of the fan is NO NO No LBFD-004012
enabled or
Indicates
disabled. the
temperature at the NO NO Yes LBFD-004012
air inlet ofthe
Indicates the TCU.
temperature at the
NO NO Yes LBFD-004012
air outlet of the
TCU.
Indicates the
temperature inside NO NO Yes LBFD-004012
Indicates
the TCU. the
Indicates
average rotationthe
physical operation
speed of the inner NO NO Yes LBFD-004012
Indicates
status
circulation the
of the fanboard,
per
Indicates
average
which the
rotation
minute.can be
operational
speed of thestate
Uninstalled, outerof NO NO Yes LBFD-004012
Indicates
the board,
circulation
Starting the
up, which
fan alarm
per
Normal,
status.
can be
minute. For
Inconsistent,set details
to
about
Enabled theordefinition
Unconfigured, NO NO Yes LBFD-004006
of Alarm
Disabled.
Power Status,
off, Enabled
Fault,
see ITU-T
indicates that
Communication X.731.
Indicates theorbe E-the NO NO Yes None
services
lost, In test, can
label,
combination of with
carried a text
on file
the
a maximum
board.
various Disabled
states. of 2For NO NO Yes LBFD-004012
KB. It is used
indicates
example, that to
no
if a board
record
service
is the
can be
not configured
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates
the main controlthe suchtype as
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
thephysical
bar
module.
operation
code of the status
board of NO NO Yes None
Indicates the
thethe
or boardcabinet.
description isabout
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.
by the board the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
cabinet.
The downlink and
uplink frequencies
of the local cell
must stay within the
same frequency
band.
The downlink and
Indicates
Frequency(MHZ) the
uplink frequencies=
manufacturer
(Frequency of the
of the local cell NO NO Yes None
board
Channel or the
must stayNumber
within the /
cabinet.
Indicates
5) + Offset the issue
Band1:
same frequency
number
band. of the
Common NO NO Yes None
board.
Frequencies
Frequency(MHZ) =
IndicatesNumber:
Channel
(Frequency the type
NO NO Yes None
of a board.
[10562-10838]
Channel Number /
Offset:
5) + Offset0 Special
Band1:
Indicates
Frequencies the object
Common NO NO Yes None
number
Channel of a board.
IndicatesNumber:
Frequencies the object
none
type ofOffset:
Channel a Number:0
board,
Band2:
[9612-9888] Common Offset: NO NO Yes None
which is CPU or
Frequencies
0 Special the
DSP.
Indicates
Channel
Frequencies Number:
temperature of a NO NO Yes None
[9662-9938]
Channel Offset:
board. Number:
0 Special
none Offset:
Indicates the 0
Frequencies
Band2:
temperature Common NO NO Yes None
Indicates
Channel theof the
Number:
Frequencies
power
service amplifier.
type of the
(412,
Channel 437,
Indicates 462,
Number:
the result
CPU
487, or
512, DSP 537,of the
562, NO NO Yes None
[9262-9538]
of the
board. operation.
The Offset:
service
587,
0 612, 637, 662,
Special
types of the DSP
687) Offset: 1850.1
Frequencies
consist of uplink NO NO Yes None
Band3:
Channel Common
Number:
and downlink
Frequencies
(12, 37, 62,
services. The 87, 112,
Indicates
Channel
137, 162, the
Number:
187, type
service
of the types
device.
[1162-1513] of212,
Offset:the NO NO Yes None
237,
CPU 262,
consist 287)of
1575
Offset: Special
Indicates 1850.1
theSlave.
Office
Master
Frequenciesand NO NO Yes None
Band3:
name ofCommonthe BS.
Channel
Frequencies Number:
Indicates
none Offset: the 0
Channel
software Number:
version of NO NO Yes None
Band4: Common
[937-1288] Offset:
the board.
Frequencies
1525 Special
Indicates the
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Offset:
Number:
Indicates
1805
none Special
Offset:the 0
BootROM
Frequencies
Band4: version
Common NO NO Yes None
of the board.
Channel
Frequencies Number:
(1887,
Indicates
Channel 1912,
the 1937,
Number:test
1962, 1987, 2012, NO NO Yes None
time.
[1312-1513] Offset:
2037,Special
1450 2062, 2087)
Indicates
Offset: 1735.1
Frequencies the test
NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762, Number:
1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862)Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5: Common
Indicates
Channel
Frequencies the
Number:
number
(1007, of
1012,
Channel Number: the1032,
YES NO No None
cabinet
1037, 1062,
[4132-4233] where the
1087)
Indicates
TCU is theOffset:
located.
Offset:
0 Special 670.1
number of the
Band6:
Frequencies Common YES NO No None
subrack where the
Frequencies
Channel
Indicates Number:
the
TCU is located.
Channel
(782, 787,
number ofNumber:
807,slot
the
[4387-4413] Offset: YES NO No None
812,
where 837,the 862)
TCU is
0 Special
Offset:
located. 670.1
Indicates the
Frequencies
Band6:
threshold Common
of the low NO NO No LBFD-004012
Channel
Frequencies
temperature Number:
state.
Indicates
(1037, the
1062) Offset:
Channel
threshold Number:
of the
670.1 Band7:
[4162-4188] Offset: NO NO No LBFD-004012
high
Commontemperature
0 Special
state.
Frequencies
Frequencies
Channel
Channel Number:
Number:
[2237-2563]
(812, 837) Offset: Offset:
2175 Special
670.1 Band7:
Frequencies
Common
Channel
Frequencies Number:
(2587, 2612,
Channel Number: 2637,
Indicates the
expected lowest
NO NO No LBFD-004012
temperature at the
Indicates
air outlet. the
tolerable
Indicates error the value NO NO No LBFD-004012
of temperature
difference between
control.
the temperature at
Indicates
the air inlet the and that NO NO No LBFD-004012
difference
of the environment between
the
at temperature
the normal at
Indicates
the air the and
outlet NO NO No LBFD-004012
temperature.
difference
that of the between
air inlet
the
at thetemperature
normal at
the air
temperature.outlet and NO NO No LBFD-004012
that of thethe
Indicates
environment
number
Indicates ofthetheat the
high temperature. YES NO No None
cabinet
communicationwhere the
Indicates
PMU is located.
address ofthethe
number
PMU, which of the is YES NO No None
subrack
determined where by thethe
Indicates
PMU the
is located.
settings of
number of the slot the 4-bit
Indicates YES NO No None
dual
where thethe
in-line package
PMU is
cabinet
(DIP)
located. number
switch on theof
the manager.
PMU. The The
Indicates thethe NO NO No LBFD-004012
manager of
communication
subrack
PMU is usually
address number
is usedaby of
the
BBUPMU
the manager.
or RRU. to The
NO NO No LBFD-004012
manager
communicate of the
Indicates
PMU is the with
usually a
the
numbermain control
of the serial
BBU
and or RRU. NO YES No LBFD-004012
port transmission
where the PMU
board. The value of
is connected.
this parameter must
NO NO No LBFD-004012
be consistent with
Indicates
Indicates
the actualthe the type
lower
settings
of the
threshold power of
of the DIP switch. AC NO NO No LBFD-004012
system
input
The 4-bit forDIP
voltage. theswitch
When
Indicates
PMU.
the the higher
canAC be input
treated as a
threshold
voltage is of AC
lower NO NO No LBFD-004012
4-bit binary number.
input
than voltage.
the value, When
an
The settings
Indicates the of ON
lower
the AC input
ALM-25622 Mains
and OFF are
threshold
voltage
Input is of
Abnormal
the DC
higher NO NO No LBFD-004012
represented
voltage. When bythe1
than
alarm the
Indicates is value,
reported.
the an
upper
and
output 0 respectively.
voltage of
ALM-25622
threshold Mains
ofis4-bit
the DC
Convert
the busbar the lower NO NO No LBFD-004012
Input
voltage. Abnormal
When the
number
than the from
value, binary
an
alarm
output isvoltage
reported. of
to decimal,
ALM-25621 and
DC
Indicates
the
then busbar
the the is
decimal flag
higher NO NO No LBFD-004012
Output
for Abnormal
power-off
than
number
alarm the
is value,
is usedan
reported. as
against
Indicates
ALM-25621
the value low of voltage,
the DCload
this
which
voltage
Output
Indicates
parameter.determines
below
Abnormal
the lower NO NO No LBFD-004012
whether
which
alarm is
threshold the
thereported.
load
of load
theis is
powered
powered off the
cabinet off in
case
Indicatesof low thevoltage.
upper NO NO No LBFD-004012
automatically
temperature. when
If the
threshold
load power-off of
cabinet temperature the
cabinet
against
is lower low thanvoltage
the NO NO No LBFD-004012
temperature.
is enabled.
value, an ALM- If the
Indicates
cabinet the
temperaturelower
25652
threshold Cabinet
of the
is higher than the
Temperature NO NO No LBFD-004012
cabinet
value, anhumidity.
ALM- If
Abnormal
Indicates
the cabinet alarm
the upper
humidity is
25652
reported.
threshold Cabinet
of the
is lower than
Temperature the NO NO No LBFD-004012
cabinet
value, anhumidity.
ALM- If
Abnormal
the cabinet alarm
humidity is
25653
reported. Cabinet
is higher than
Humidity Abnormal the NO NO No LBFD-004012
value, an ALM-
alarm is reported.
25653 Cabinet
Humidity Abnormal
alarm is reported.
Indicates
Indicates whetherthe
to allow the
charging or report
of a dedicated
discharging status
Indicates
analog whether
alarm. If the
of batteries.
to allow the Boost
report
shield
charge flag for
is used to an NO NO No LBFD-004012
of a dedicated
analog alarm is the
quickly
Boolean recover
alarm. If
enabled,
capacity the
offlag analog
thefor a
the
alarmshield
cannot NO NO No LBFD-004012
Indicates
battery.
Boolean the beis
During
alarm the
reported.
current AC
boost charge, voltage,
the
enabled, the
that is, the
charging
Boolean input is
voltage
alarm NO NO Yes LBFD-004012
mains
relatively
cannot voltage
high.
bethe to
reported.After
Indicates
rectifier.
the battery is DC
output
discharged,voltage of NO NO Yes LBFD-004012
the busbar.
generally, the
Indicates the
Indicates the total
system
power-on status of NO NO Yes LBFD-004012
load current. starts
automatically
the secondary
Indicates the load.
boost-charge
The secondary on the
current cabinet load
battery.
can Floating
be set toof the NO NO Yes LBFD-004012
temperature
charge is used to
automatically
cabinet.
Indicates the for the
compensate
powered off in the
ambient
power losshumidity
of the of NO NO Yes LBFD-004012
following
the cabinet. modes:
battery due to self-
HighTemperaturePo
discharge
werOff(High and to NO NO Yes LBFD-004012
keep the capacity
temperature powerof
the
off),battery. It can
also recover the
LowTemperaturePo NO NO Yes LBFD-004012
battery
Indicates
werOff(Low capacity.
the
During
charging
temperature the or floating
Indicates thepower NO NO Yes LBFD-004012
charge,
discharging
off), and the
Indicates whether current
power-on/power-off
charging
of batteries.
LowVoltagePowerO
the voltage is
status of the that
batteries
relatively
ff(Low
are being low.
voltagecharged Force NO NO Yes LBFD-004012
battery. The battery
boost
power
are in charge
off).current is an
can bethe
enhanced
limiting status. of
mode
disconnected
Indicates
the boost the charge. NO NO Yes LBFD-004012
manually
remaining orcapacity
The charging
disconnected
of the battery by
current and boost
automatically
displaying the for NO NO Yes LBFD-004012
charging voltage of
protection
percentage purpose
of the
the force boost
Indicates the
based
current on different
capacity to
charge
current are higher
temperature NO NO Yes LBFD-004012
situations.
the total capacity.
than those
of the battery. of the
boost charge, while
Indicates
the charging the timephase is NO NO Yes LBFD-004012
of the battery
shorter than test.
Indicates thethat totalof
the boost
current of charge.
the It
can be used in the NO NO Yes LBFD-004012
photovoltaic
Indicates the array
scenario
of the PMU.
current ofwhere
the diesel the
electricity
generator network
which is is NO NO Yes LBFD-004012
Indicates
unsatisfactory the and
managed by of
temperature the
the battery
PMU. battery is
auxiliary
discharged NO NO Yes LBFD-004012
cabinet
frequently. which is
connectedthe
Indicates to the
PMU.
software version of NO NO Yes None
the PMU.
Indicates the PCB
NO NO Yes None
version ofthe
Indicates the PMU.
erasable
programmable logic NO NO Yes None
device version of
Indicate
the PMU.the
software compiling NO NO Yes None
time of the PMU.
Indicates the
version description NO NO Yes None
of the PMU.
Indicates the
manufacturing date NO NO Yes None
of the PMU.
Indicates the
manufacturer of the NO NO Yes None
PMU.
Indicates the PSU
intelligent shutdown
NO NO Yes None
capability of the
Indicates
Indicates
PMU. the
the status
of the PSU
physical operation NO NO Yes None
intelligent
Indicates
status shutdown
the
of the board,
switch can
Indicates
execution
which of thebePMU.
the
result of
operational
the setting of
Uninstalled, state
the of NO NO Yes None
Indicates
the
PSUboard,
Starting the
up, alarm
which
intelligentNormal,
status.
can be For
set
shutdown switch.
Inconsistent, details
to
about
Enabled theordefinition
Unconfigured, NO NO Yes LBFD-004006
of Alarm
Disabled.
Power Status,
off, Enabled
Fault,
see ITU-T
indicates that
Communication X.731.
Indicates theorbe
E-the NO NO Yes None
services
lost, can
In test,
label,
combination of with
carried a text
on file
the
a maximum
board.
various Disabled
states.of 2For NO NO Yes LBFD-004012
KB. It is used
indicates
example, that to
no
if a board
record
service
is the
can be
not configured
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates the
the main control such
type as
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
physical
the bar
module.
operation
code of thestatus
board of NO NO Yes None
Indicates the
thethe
or board isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.
by the board the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU the of
or DSP result
the NO NO Yes None
of the operation.
board. The service
types of the DSP
consist of uplink NO NO Yes None
and downlink
services.
Indicates The
the type
service types of the NO NO Yes None
of the device.
CPU consist of
Master and Slave.
487, 512, 537,
[9262-9538] 562,
Offset:
587,
0 612, 637, 662,
Special
687) Offset: 1850.1
Frequencies
Band3:
ChannelCommon Number:
Frequencies
(12, 37, 62, 87, 112,
Channel
137, 162,Number: 187, 212,
[1162-1513]
237, 262, 287) Offset:
1575
Offset: Special
1850.1
Indicates the Office
Frequencies
Band3: NO NO Yes None
name ofCommon the BS.
Channel
Frequencies Number:
Indicates
none Offset: the 0
Channel
software Number:
version of NO NO Yes None
Indicates
Band4: Common
[937-1288] the Offset:
the board.
installation
Frequencies type of
1525 Special
Indicates the
batteries.
Channel This
hardwareNumber:
Frequencies version of NO NO Yes None
parameter
[1537-1738]
Channel can
Number: be
Offset:
the board.
set to Offset:
Indicates
1805
none INNER
Special the 0or
OUTER.
BootROM
Frequencies
Band4: The
Commonversion value NO NO Yes None
INNER
of the indicates
board.
Channel Number:
Frequencies
that
(1887,batteries
Indicates
Channel 1912, the 1937,
Number: are
test
installed
1962, 1987, in the2012, NO NO Yes None
time.
[1312-1513] Offset:
power cabinet.
2037,Special
1450 2062, 2087) The
Indicates
value OUTER
Offset: 1735.1
Frequencies the test
NO NO Yes None
result.
indicates
Band5: Common
Channel that
Number:
batteries
Frequencies are
(1662, 1687, 1712,
installed
Channel
1737, 1762, in an
Number: 1787, NO NO Yes None
independent
[4357-4458]
1812, 1837, 1862) battery
Offset:
cabinet.
0 Special
Offset: For
1380.1 lithium
ion batteries,
Indicates
Frequencies the this NO NO Yes None
Band5: Common
parameter
number
Channel
Frequencies of is set to
the
Number:
INNER.
cabinet
(1007,
Channel For
where
1012,Number: lead- the
1032,
Indicates the this YES NO No None
acid
PMU
1037, batteries,
managing
1062,
[4132-4233] 1087)
Offset: the
Indicates
number
parameter ofwhether
the
can beis
diesel
Offset:
0 Specialgenerator
670.1
intelligent
subrack
set to either control
where INNER theof
located.
Band6:
Frequencies
Indicates Common
the YES NO No None
the
PMU
or diesel
managing
OUTER, generator the
Frequencies
Channel
number
is enabled. ofNumber:
the
When slot
diesel
depending generator on theis
Channel
(782,
where theNumber:
787,
intelligent 807,
PMU
control is
located.
type of the power YES NO No None
[4387-4413]
Indicates
812, 837,the
managing
enabled, theOffset:
the
862) PMU
cabinet.
0 Special
maximum
Offset:
diesel When
670.1
generatorratedthe is
automatically
power cabinet isthe
Frequencies
output
Band6:
located.
controls power
Common
theversion of
diesel NO NO No None
APM30
Channel
diesel of Number:
generator.
Frequencies It
generator
301 (silkscreen: according
(1037,
should
Channel
to the 1062)
beNumber:
preset Offset:
APM30)
670.1
configured
[4162-4188] or 302
Band7: Offset: NO NO No None
parameters,
(silkscreen: thus
Common
according
0 Special
reducing to
the the
Indicates
APM30H),
Frequencies
rated output
Frequencies thethis oil
power
operation
level of
parameter the cost
diesel
is set of as NO NO Yes None
Channel
printed
Channel
the diesel Number:
onNumber:
the name
generator.
required.
[2237-2563]
plate
(812, of837) the When Offset:
diesel
Offset: the
generator.
Indicates
power cabinet the is not
2175
current Special
generator.
670.1 Band7:
of NO NO Yes None
APM30
Frequencies
Common of the version diesel
generator.
301 or 302,
Channel
Indicates
Frequencies thethis
Number: total
parameter
(2587,
running
Channeltime2612, is of
Number: set
2637,
the to NO NO Yes None
Indicates
INNER.
2662,
diesel The
2687, the
generator.
[2012-2338] Offset: 2712,
number
reasons
2737,Special
2100 of
2762,arethe as
2787,
cabinet
follows: where
In
2812, 2837, 2862,
Frequencies an the YES NO No None
Indicates
PMU
APM30 managing
of the
version the
2887, 2912)
Channel Offset:
number
battery
301 or isofNumber:
302, the
located.
the
2105.1
(2362,
Indicates Band8:
2387, the 2412,boost
subrack
battery where
temperature the YES NO No None
Common
Indicates
2437,managing
charging 2462, the
voltage.2487,
PMU
Indicates
sensor is the
connected the
Frequencies
number
2512,
Boost oflocated.
2537,
charge the isslot
2562,
battery
scheduled
to differentis boost
ports on
Channel
where
2587,
used the
to2612, Number:
quicklyPMU 2637, YES NO No None
charging
the APMI interval.
board by
[2937-3088]
managing
2662,
recover 2687)
the Offset:
theOffset:
Batteries
the battery are boost-
340
2030.1Special
battery
capacity is
Band8:
oflocated.
charged
temperature at thissensor NO NO No None
Frequencies
Common
batteries.
interval
cable, (inDuring
depending the unit
Channel
Frequencies
the boost Number:
charge,
of
on day),
the which
installation
none
Channel
the Offset:
charging Number: 0
keeps
type the
of lead-acidbatteries NO NO No None
Band9:
[2712-2863]
voltage
Indicates Common
is relatively
the Offset:
fully charged.
batteries. When This the
Frequencies
340
high. Special
After
capacity ofthe battery
parameter
installation is
type is
Channel
Frequencies
batteries
1. Number:
This parameterare NO NO No None
configured
INNER, the battery
[9237-9387]
Channel
discharged,
should beNumber: set Offset:
the
according
temperature to the
sensor
0 Special
none
system Offset:
according to 0 the
instructions
is connected to the NO NO No None
Frequencies
Band9:
automatically
actual Common
situation. starts
provided
BAT_TEM1 by port.
Channel
Frequencies
boost
Incorrect Number:
charge on the
manufacturers.
When theNumber:
none
Channel Offset:
batteries.
configuration This 0. The
installation
frequency
[8762-8912]
parameter oftype
is theis
Offset:
reduces the life
OUTER,
local
0 cell
configured
Special the
must battery
be
span of the battery.
temperature
the same as
Frequencies
according to sensor
that
the of
is
theconnected
bearing
Channel
instructions Number: to the
logical
BAT_TEM2
cell.
none Offset:
provided by 0. port.
The configuration
coefficient.
Charging coefficient
Indicates
x Storagethe capacity
floating
= Maximum charging
voltage.
chargingFloating
current.
charge
When the is used
charging to
compensate
current is not the for
power
smallerloss thanofthe the
batteries due to NO NO No None
maximum charging
self-discharge.
current plus 5 A,The an
floating
ALM-25625 charging Battery NO NO No None
voltage
Current is
Indicates lower
whether
Abnormal
than
to the
enable boost
battery
alarm is reported.
Indicates the
charging
disconnection
This parameter
temperature voltage.
above is NO NO No None
This
againstparameter
configured
which thehighbattery is is
configured
temperature.
accordingoff
powered
Indicates to the
the
according to the NO NO No None
instructionsor
automatically
increased under
instructions
Indicates
provided
the condition
reduced whether
by
charging that
Indicates
provided
to enable the
bybattery
manufacturers.
HtempShutdownFlg
voltage
voltage of
belowevery NO NO No None
manufacturers.
power-off
is enabled.
battery when againstthe is
which
low the
voltage. battery
ambient
powered off
temperature isunder
1 NO NO No None
automatically
Indicates the lower
degree
the Celsius
condition that
limit
higher of or
temperature.
lower than
LvolShutdownFlg
When the battery is NO NO No None
the standard
enabled.
Indicates theisupper
temperature
temperature
limit
below ofthe
temperature.
lower
specified
When the by
battery NO NO No None
limit, an ALM-25650
manufacturers. This
temperature
Environmental
parameter
exceeds should
the upper
Temperature
be setanaccording to NO NO No None
limit,
Abnormal ALM-25650
alarm is
the instructions
Environmental
Indicates
reported. the
provided
Temperature by
number of battery NO NO No None
manufacturers.
Abnormal alarm is
groups.
reported.
Indicates the type
NO NO No None
of the battery.
Indicates the
number of times
NO NO Yes None
that the battery
Indicates the is
poweredofoff.
number times
that the battery is NO NO Yes None
Indicates
charged inthe half an
number
hour. of times
that the battery is NO NO Yes None
Indicates
charged inthe one
number
hour. of times
that the battery is NO NO Yes None
Indicates
charged inthe two
number
hours. of times
that the battery is NO NO Yes None
Indicates
charged inthe three
number
hours. of times
that the battery is NO NO Yes None
Indicates
charged inthe four
number
hours. of times
that the battery is NO NO Yes None
Indicates
charged inthe five
number
hours. of times
that the battery is NO NO Yes None
Indicates
charged inthe six
number
hours. of times
that the battery is NO NO Yes None
Indicates
charged inthe seven
number
hours. of times
that the battery is NO NO Yes None
Indicates
charged inthe eight
number
hours. of times
that the battery is NO NO Yes None
Indicates
charged inthe more
number
than eight of hours.
times
that the battery is NO NO Yes None
discharged in half
an hour.
Indicates the
number of times
that the battery is NO NO Yes None
Indicates
discharged the in one
number
hour. of times
that the battery is NO NO Yes None
Indicates
discharged the in two
number
hours. of times
that the battery is NO NO Yes None
Indicates
discharged the in three
number
hours. of times
that the battery is NO NO Yes None
Indicates
discharged the in four
number
hours. of times
that the battery is NO NO Yes None
Indicates
discharged the in five
number
hours. of times
that the battery is NO NO Yes None
Indicates
discharged the in six
number
hours. of times
that the battery is NO NO Yes None
Indicates
discharged the in seven
number
hours. of times
that the battery is NO NO Yes None
Indicates
discharged the in eight
number
hours. of times
Indicates the date
that the battery is NO NO Yes None
when the
Indicates
discharged battery
the in more is
installed.
capacity ofThe
than eight hours. battery
scheduled
2. tests for
This parameter NO NO Yes None
the battery
should be
Indicates the are
set
dependent
accordingoftoonthe
duration the
installation date. NO NO No None
actual situation.
Indicates
discharging thethe
Indicates
Incorrect
numberwith
battery ofthe thethe
duration
current of0.05C10
configuration
cabinet ofwhere the YES NO No None
Indicates
discharging
reduces
PMU
to the thethe
the
managing
moment life the
Indicates
number
battery
span of ofthe
with thethe
battery
when isthe
the
duration
battery.
oflocated.
subrack
current of
discharging where
0.1C10 theto YES NO No None
Indicates
discharging
PMU
the thevoltage
managing
moment the
when the
is terminated.
Indicates
number
battery ofthe
with thetheC10
slot
battery
the is located.
discharging
indicates
duration ofthe
where
current
voltage the
of PMU to
0.2C10
iscapacity YES NO No None
nominal
discharging
managing
the moment the whenof
the
terminated.
Indicates
the battery,
battery with the C10
and
the
battery
the is located.
discharging
indicates
duration ofthe
0.05C10
current
voltage of indicates
0.3C10 to
iscapacity NO NO No None
nominal
discharging
that
the the
momentbattery the
when is of
terminated.
Indicates
the battery,
battery with C10
theandthe
discharged
the discharging
indicates
duration ofthe with the
0.1C10
current
current
voltage indicates
of
of
is 0.4C10
0.05 x of to NO NO No None
nominal
discharging
that
the the
moment capacity
battery the
when is
norminal
terminated.
Indicates
the battery,
battery withcapacity
C10
theandthe the of
discharged
the
the discharging
battery.
indicates
duration ofthe with
For
0.2C10
current
current indicates
xof 0.5C10 x to NO NO No None
voltage
example,
nominal
discharging
that
the the
moment if0.1
iscapacity
batterythe
the
when is of
norminal
terminated.
Indicates
the battery,
battery withcapacity
C10
theand
capacity the is of
discharged
the
the discharging
battery.
indicates
duration ofthe with
For the
100 AH,of
0.3C10
current
current of0.05C10
indicates
0.6C10 to NO NO No None
voltage
example,
nominal
discharging
indicates
that
the if0.2
iscapacity
that
the battery
moment the
thex of
the
when is of
norminal
terminated.
Indicates
the capacity
the
capacity
battery,
battery with C10
the is
and
battery
the
the isof
discharged
discharging
battery.
indicates
duration the with
For the
100 AH,
0.4C10
current
discharged
current of
of0.1C10
indicates
0.7C10
withx the to NO NO No None
voltage
example,
nominal
discharging
indicates
that
the the
moment if0.3
iscapacity
that
batterythe
thethe
when is of
current
nominal
the ofcapacity
terminated. 5 and
capacity
battery,
battery with AH.
C10
the theisof
battery
the is thewith
discharged
the discharging
battery.
indicates For
100 AH,
0.5C10
current
discharged
current of
of0.2C10
indicates
0.8C10
withx the to NO NO No None
voltage
example,
nominal
indicates
that
the the of
moment if0.4
iscapacity
that
batterythe the
when is of
current
nominal
terminated.
battery
the 10
capacity
capacity
battery, AH.
C10
and the isof
battery
the is thewith
discharged
the discharging
battery.
indicates For
100 AH,
0.6C10
discharged
current of0.3C10
indicateswithx the NO NO No None
voltage
example,
nominal
indicates
that the of if0.5
iscapacity
that
batterythe theis of
current
nominal
terminated.
battery
the 20
capacity
capacity
battery, AH.
C10
and isof
battery
the is thewith
discharged
battery.
indicates For the
100 AH,
0.7C10 of
discharged
current 0.4C10
indicateswithx the NO NO No None
example,
nominal
indicates
that the of if0.6
that
batterythe
capacity theis of
current
nominal
battery
the 30
capacity
capacity
battery, AH.
and isof
battery
the is with
discharged
battery. For the
100 AH,of
0.8C10
discharged
current 0.5C10
indicateswithx the NO NO No None
example,
indicates
that the if0.7
that
batterythe theis of
current
nominal
battery of 40
capacity
capacity AH. is
battery is
discharged
the battery. with
For the
100 AH,of0.6C10
discharged
current 0.8 withx the
example,
indicates if thethe
that
current
nominal
battery ofcapacity
50 AH. of
capacity
battery
the is For is
battery.
100 AH, 0.7C10
discharged with the
example,
indicates if the
that the
current
battery of 60 AH.
battery capacity
is is
100 AH, 0.8C10
current of 0.9C10 to
the moment when
the discharging
Indicates
voltage is the
charging
terminated. efficiency
C10
of
indicates theThe
batteries.
battery
nominalefficiency
capacity of is
a
thepercentage
battery, and of
battery
0.9C10 indicates NO NO No None
Indicates
performance the to test the
that
mode. the It battery
specifies is
normal
discharged battery withthe the
whether
capacity. to use
current ofFor
automatic 0.9
test xand NO NO No None
example,
nominal a normal
capacity
which
Indicates
battery automatic
can end of
thesupply
the
test battery.
mode
voltage of 10theFor
is used. NO NO No None
power
Indicates
example, for the
iffour
the hours.
time
There
discharging
If a are
battery test.
can
limit for
Indicates
types the
batteryofcapacitythe
test is
supply
100 AH,power
simplified
quantity 0.9C10
of for
battery NO NO No None
modes:
only
in theeight
discharging
indicates
NOAUTOTEST
hours,
that
battery test.
the
group.
(No
its
battery
Indicates
There
battery efficiency
are the
is two time
types is
Auto
80%. Test), PERIOD
limit
of of the
discharging
discharged tests NO NO No None
(Period Autowith Test),the
discharging
for of 90test.
a battery:
current a
AH.
POWERCUT
standard
(Power Off test Auto and a
NO NO No None
simplified
Test), test.
andthe end A
Indicates
standard test
PERIODPOWERC
voltage of the
calculates
UT (Period the
and NO NO No None
simple
Indicates
battery discharging
the
efficiency, time
Power
test.
limit for Offthe Auto
and
Test). a
Indicates simplified
No Autothetest test
Test:
type
discharging
judges only the NO NO No None
indicates
of the when
delay that
battery the the
test.
quality
Indicates
battery
There of
test
are the is time
power of is
battery.
limit the off or types
two the
launched
of battery
discharging and
tests:
test is NO NO No None
scheduled
controlled
STANDARD(Standa by the
launched
discharging test.
user.
rd Test)Period
automatically.and Auto The
Test: indicates
SIMPLE(Simple that NO NO No None
interval between
the
two battery testsis
Test).battery
Standard test Test
launched
is used to
must be greater calculate
NO NO Yes None
automatically
the
than efficiency
this time by
of the
the
limit.
Indicates
system
battery. as the test
Simple Test
Otherwise,
start date, the is
which
scheduled.
is used
execution onlyof Power
to
the NO NO Yes None
in
Offthe
judgeAuto format
the Test:
quality of of
STR BATTST
YYYY/MM/DD.
Indicates
indicates
the battery, the
that butend
thenot
command fails.
reason
battery of
test
to calculate the the is NO NO Yes None
battery
launched
efficiency test.of the
automatically
battery.
Indicates This
thetest by the
result
Indicates
system the the
after AC NO NO Yes None
takes
of the abattery
short time.
test.
battery
power supply efficiency. is cut
The
off. battery is NO NO Yes None
normal when the
Indicates
result is betweenthe
continued
80% and 100%. NO NO Yes None
discharge duration
Indicates
of the battery. the
voltage of the
NO NO Yes None
battery when the
Indicates
dischargethe is ended.
average current in
Indicates theof the NO NO Yes None
the process
accumulated
battery discharge.
discharged power
NO NO Yes None
(Ah) from the
beginning
Indicates the of
discharge.
current temperature NO NO Yes None
of the battery.
Indicates the
number of the
YES NO No None
cabinet where the
Indicates
PSU is located. the
number of the
YES NO No None
subrack where the
Indicates
PSU is located. the
number of the slot
YES NO No None
where the PSU is
located.
Indicates the
running status of NO NO Yes None
the PSU.
Indicates
Indicates the the
physical
manufacturing operationdate NO NO Yes None
status of the board,
of the PSU.
Indicates
which canthe be
operational
manufacturer
Uninstalled, state of
of the NO NO Yes None
Indicates
the
PSU. board,
Starting the
up, alarm
which
Normal,
status.
can be Forset to
Inconsistent, details
about
Enabled the
Unconfigured, ordefinition NO NO Yes LBFD-004006
of Alarm
Disabled.
Power Status,
off, Enabled
Fault,
see ITU-T
indicates that
Communication X.731.
Indicates theorbe
E-the NO NO Yes None
services
lost, can
In test,
label,
combination of with
carried a text
on file
the
a maximum
board.
various Disabled
states.of 2For NO NO Yes LBFD-004012
KB. It is used
indicates
example, that to
no
if a board
record
service
is the
can be
not configured
manufacturing
carried
and failsontothe NO NO Yes None
information
board.
communicate about
with
equipment
Indicates the
the main control such
typeas
the board, sub- NO NO Yes None
of
andthe board.
transmission
board,
board, or
Indicates theoptical
physical
the bar
module.
operation
code of thestatus
board of NO NO Yes None
Indicates the
thethe
or board isabout
cabinet.
description
Unconfigured,
the services and
Communication NO NO Yes None
functions provided
Indicates
lost.
by the board the or the
manufacturing
cabinet. date
NO NO Yes None
of the board or the
Indicates
cabinet. the
manufacturer of the
NO NO Yes None
board or the
cabinet.
Indicates the issue
number of the NO NO Yes None
board.
Indicates the type
NO NO Yes None
of a board.
Indicates the object
NO NO Yes None
number of a board.
Indicates the object
type of a board,
NO NO Yes None
which is CPU or
DSP.
Indicates the
temperature of a NO NO Yes None
board.
Indicates the
temperature
Indicates theof the NO NO Yes None
power
serviceamplifier.
type of the
Indicates
CPU the of
or DSP result
the NO NO Yes None
of the operation.
board. The service
types of the DSP
consist of uplink NO NO Yes None
and downlink
services.
Indicates The
the type
service types of the NO NO Yes None
of the device.
CPU consist of
Indicates
Master and theSlave.
Office
NO NO Yes None
name of the BS.
Indicates the
software version of NO NO Yes None
the board.
[1162-1513]
237, 262, 287) Offset:
1575 Special
Offset: 1850.1
Frequencies
Band3: Common
Channel
Frequencies Number:
none Offset:
Channel Number: 0
Band4: Common
[937-1288] Offset:
Frequencies
1525 Special
Indicates the
Channel
hardwareNumber:
Frequencies version of NO NO Yes None
[1537-1738]
Channel
the board. Number: Offset:
Indicates
1805
none Special
Offset: the 0
BootROM
Frequencies
Band4: Commonversion NO NO Yes None
of the board.
Channel
Frequencies Number:
(1887,
Indicates
Channel 1912,the 1937,
Number: test
1962, 1987, 2012, NO NO Yes None
time.
[1312-1513] Offset:
2037,Special
1450 2062, 2087)
Indicates
Offset: 1735.1
Frequencies the test
NO NO Yes None
result.
Band5: Common
Channel Number:
Frequencies
(1662, 1687, 1712,
Channel
1737, 1762, Number: 1787, NO NO Yes None
[4357-4458]
1812, 1837, 1862) Offset:
0 Special
Offset: 1380.1
Frequencies NO NO Yes None
Band5:
Indicates Common
the
Channel
Frequencies
cabinet Number:
number of
(1007,
Channel
the board 1012,
Number:
where 1032, the YES NO No None
1037,
output1062,
Indicates
[4132-4233]port the is1087)
Offset:
Offset:
subrack
0 Special
located. 670.1
number of
Band6:
the board
Frequencies Common
where the YES NO No None
Indicates
Frequencies
output port the is slot
Channel Number:
number
Channel
located. ofNumber:
the
(782, 787, 807,
board where Offset:
[4387-4413] the YES NO No None
812, 837, 862)
output
0 Special port is
Offset:
Indicates 670.1the
located.
Frequencies
Band6:
number Common of the YES YES No None
Channel
Frequencies
output port.Number:
(1037,
Channel 1062)
Number: Offset:
Indicates
670.1 Band7: the name
[4162-4188] Offset: NO YES No LBFD-004012
of the output port.
Common
0 Special the
Indicates
Frequencies
Frequencies
enabled/disabled
Channel
Channel Number:
Number: NO NO No LBFD-004012
state of the output
Indicates
(812, 837)the
[2237-2563]
port. Offset:
Offset:
cabinet
2175 Special
670.1 number of
Band7: YES YES No None
the board where the
Frequencies
Common
Indicates
port is located.
Channel the
Number:
Frequencies
subrack number of
(2587,
Channel 2612,
Number: 2637, YES YES No None
Indicates
the board the
where alarm the
2662,
Indicates 2687,
[2012-2338] the 2712,
Offset:
slot
port types:
is located. analog
2737,
2100
number 2762,
Special
of andthe 2787,
alarm port YES YES No None
2812, 2837,
Frequencies
board where 2862,
the
digital alarm port.
2887,
Indicates
Channel
port is 2912) the
Number:
located. Offset:
An analog alarm
Indicates
2105.1
(2362, the 2412,
Band8:
enabled/disabled
2387, port
port is used to YES YES No None
number.
Common
state of2462,
the
2437,
monitor the port. 2487,
external
Frequencies
Alarms
2512, can be
2537, 2562,
environment
Indicates the2637,that
alarm
Channel
detected
2587,
Indicates 2612, Number:
and
the alarm NO NO No LBFD-004012
changes
ID bound to the
[2937-3088]
reported
2662,
upper 2687)
limit.through Offset:
IfOffset:
the
continuously.
alarm port. This The
340
the
2030.1Special
port
environment only
Band8: when
port is
Indicates
parameter supported
theisthe alarm NO NO No LBFD-004012
Frequencies
Indicates
the state
Common
measurement the
of alarm
port
value
only
level. by
reported Thistheas EMU.
the IDA
Channel
lower
is
is ON. limit.
Frequencies
greater Number:
If
than the the
digital
parameter
of alarm
theOffset:
alarm port
specifies is
none
environment
Channel
alarm upper Number: 0
limit
used
whether
detectedto monitor
alarms
at the the
port. NO NO No LBFD-004012
Band9: Common
measurement
[2712-2863]
configured value
forOffset:
the
external by
generated the
Frequencies
is
340smaller
Special
sensor, than
the alarm the is
environment
sensor over of port
the
Channel
alarm lower
Frequencies
reported. Number:limit NO NO No LBFD-004012
which
are the
in high or change low is
[9237-9387]
configured
Channel
Environment forOffset:
Number: the
indicated
voltage. in
Thealarm alarmis
0 Special
sensor,
none the
Offset:
measurement 0 value
Boolean
level is or discrete
set NO NO No LBFD-004012
Frequencies
reported.
Band9:
= Common
Measurement
values.
according It isto the
Channel
Environment
Frequencies
Indicates
lower limit Number:
the
+ the
contained
type of in
external
none
Channel
sensor Offset:
measurement
(Measurement Number:
type. 0.value
The The
EMU,
sensor. PMU, TCU, NO NO No LBFD-004012
frequency
= Measurement
[8762-8912]
user
upper can setof
limit - and the
Offset:
the
FMU, RRU,
local
lower
0 cell
limit
Special
sensor
Measurement typemust
+ to lowerbe
power boards. The
the same
(Measurement
Frequencies
current
limit) x type as or
(Observed that of NO NO No LBFD-004012
SC48200 PMU
the
upperbearing
Channel
voltage
electric limit - logical
Number:
type
does notcurrent support or
cell.
Measurement
none Offset:
according
voltage to 0.
- Output thelower
digital ports.
limit)
lowerxlimit)/(Output
actual (Observed
external
electric
sensor.
upper limit current- Output or
voltage
lower limit).- Output
lower limit)/(Output
upper limit - Output
lower limit).
Indicates the period
based on which
NTP time
Indicates the
synchronization is
measurement
performed
upper limit ofIfthe
periodically. this
Indicates
analog
parameter port. theisTheset to
measurement
range
a valueisgreater set basedlower
than NO NO No LBFD-004012
Indicates
limit of the theanalogupper
on
1,
limit the
the of actual
switch
therange for
output
port.
situations
periodic The NTP such time is
as
signals
set based from on the
the NO NO No LBFD-004012
the temperature
Indicates
synchronization
analog port. theFor lower is
actual
and
limit
turned of situations
humidity.
the
on output
Indicates
sensors of theeitherkey
such
signals asfrom
automatically.The the the
used
the for NTP
current type
temperature
analog
time of an port. andor
For
eNodeB
NO NO No LBFD-004012
authentication.
voltage type, the
humidity.
sensors
may have of either
The
upper key limitused should by
current
differences
be set accordingthe
the DES_S type
with orto NO NO No LOFD-001024
voltage
standard
algorithm
Indicates type,
the specifications is athe
time,
the andof
lower
a large
hexadecimal limit
authentication
the sensor. should
difference
be set according NO NO No None
affects
mode of theaccuracy
number thewhose SSL to
the
of
length specifications
KPIs.
connection. is
Indicates the IPv4Therefore,
64 bits inof
the
a sensor.
period
binary must
format.
address of the NTP be
The YES NO No None
configured
first
server. seven bits for the of
eNodeB
each
Indicates bytetothe perform
are used
time
to construct
number of the 56-bitport NO YES No None
synchronization
key
on data,
the NTP and serverthe
with thebitwhich
eighth
through NTPis the server
odd
time
periodically
parity bit for to eachis NO NO No None
synchronization
ensure
byte.
performed
Indicates Any thethe accurate
empty
between
switch bit
time.
is
of filled
theNTP NTPtime with
client 0 to and NO NO No None
The
ensure
the period
server.
synchronization.that for the key
periodic
Indicates
data NTP
is composedthe mode time
synchronization
of thehexadecimal
16 IP address of YES NO No None
must
the
digits NTP
Indicates be
andconfigured
server.
has an
the
Indicates
based
odd numberon the
thefor IPv6
NTP
authentication
address of the NTP YES NO No None
server
parity
mode, performance,
checks.
which The
server.
transport
key used network by the
indicates the
quality,
encryption eNodeB
DES_N and
algorithm is NO NO No None
quantity.
similar to the
standard. Thekey value
A smaller
used
Indicates
PLAIN period
byindicates
thethe DES_S for
periodic
algorithm.
server-side
that encryption NTP The time
index only
is of NO YES No None
synchronization
difference
the NTP the
not applied. is that
Indicates start
leads
the to bithigher
datefirst
authentication
mode in
of each key.
the NO YES No None
loads
byte
The is for
index the the odd
must NTP be
NE DST. There are
server
parity
the same
Indicates andan
bit. The
as NTPthe key
three formats:
transport
used
setting
server byison network.
the
an the DES_A
active A NO NO No None
date format, for
larger
algorithm
server. period
or standbyApril is anleads
server.
example, 1st;
to lower
ASCII loads.
string offorone
week
Indicates format, the time
to eight characters.
example, theNE. first NO NO No None
zone of the
The
Sunday leastinsignificant
April;
seven
Indicates
date and digits of the
whether
week
ASCII value NO NO No None
DST is enabled.
format, for example,
corresponding
for example, April to
each
1st and Sunday.are
character If it NO NO No None
use to construct
is Sunday on April 56-
bit
1st,key
Indicates
April data. theFor
1st ismonth
the
any
date. Otherwise, of
in ASCII
which the string
NE NO NO No None
less
DST
the than
starts.
first eight
Sunday
Indicates
characters, the0sdate
after
on which Aprilthe 1st NE isarethe NO NO No None
appended
date. to the
DST
string starts.
to ensure that
GUI value
Indicates inrange:
which
the
week key
DATE(Date data
the NEmode), isDST NO NO No None
composed
WEEK(Week
starts. of 56
bits.
Indicates
mode), The key the used week
by
in the
which the
Indicates
DATEWEEK(Date MD5 theNE time NO NO No None
algorithm
DST
when
and week starts.
the NE is anDST
mode)
encrypted
starts. TheASCII value of
string of one to NO NO No None
this parameter
eight
observes characters.
the
standard time.
date mode of the
NE DST. There are
three formats:
date format, for
example, April 1st;
week format, for
example, the first
Sunday in April;
date and week NO NO No None
format, for example,
Indicates
for example, the April
month
in which the
1st and Sunday. If it NE NO NO No None
DST
is ends.on April
Sunday
Indicates the date
1st, April 1st
on which the is NE the NO NO No None
date.
DST ends. Otherwise,
the first Sunday
Indicates in which
after April
week the NE 1st DST is the NO NO No None
date.
ends.
Indicates
Indicates the the weekDST
in which
Indicates
time the
offsetthe ofNE time
the NO NO No None
DST
when
NE. This ends.
theparameter
DST of
the
can NE be setends. to a The
NO NO No None
value of this
negative value. A
parametervalue
negative observes
DST.
indicates that the NO NO No None
Indicates
NE time isthe offset
earlier
Indicates
of time
Indicates zone.the
the date
This
than
to be the
set DST
for thetime, NE.
parameter
current
and a date
positive can and be
value NO NO No None
The
set
time format
to a negative
of thethat is
NE.theas The
indicates
follows: YYYY-MM-
value.
query
NE time result
is is the
later
DD. For
Indicates
local timeexample,
the time
of time.
the NO NO Yes None
than the
2006-09-08 NE
to be set for the
NE, including theNE.
indicates
The format
year, month, day, is as
September 8th of NO NO Yes None
follows:
hour, minute, HH:MM:SS.
2006.
For example,
second, and time
10:20:05.
zone. If the DST of NO NO Yes None
the NE is the
Indicates effective,
Indicates
the queryreference
external the
result date
and time
contains of
a DST the last
flag NO NO No None
time source of the
successfully-
(the
NE. flog used to
synchronized
indicate whether time
NO NO Yes None
of
thetheDST NE. is The
applied).
format
The format is asisfollows:as
Indicates
Indicates
YYYY-MM-DD the
the index
follows: YYYY-MM- YES YES No None
of the operator.
extended
HH:MM:SS. QoS
DD HH:MM:SS.
Class Identifier
(QCI), which is YES YES No None
required by
Indicates the QoS ID of a
operators
class for user
identifier
service-based inter- LOFD-001043
differentiation.
(QCI) of an evolved NO NO No
RAT handover LOFD-001046
packet
policy group.system
Indicates
(EPS) the index
bearer. YES YES No None
of the operator.
Different QCIs
indicate different
QoS requirements, YES YES No None
such
Indicates as the thepacket
ID of a
delay budget,
service-based inter- LOFD-001043
Indicates
packet errortheloss NO NO No
RAT handover LOFD-001046
medium-priority
rate, and resource
policy group.
system
Indicates
type. For todetails,
be index
the
Indicates
considered the low-
inhigh-
blind YES YES No None
of
see the operator.
Table 6.1.7
priority
handovers system for CStoinbe
3GPP
considered TS 23.203. LOFD-001033
fallback. It isin blind NO NO No LOFD-001034
handovers
GERAN by for CS
default.
fallback. It is LOFD-001035
If this parameter is LOFD-001033
CDMA2000
UTRAN
set to null, by the by
default. NO NO No LOFD-001034
default.
system with If thisthe LOFD-001035
parameter
medium blind is set to LOFD-001033
null, the system
handover priority is NO NO No LOFD-001034
with the low blind
not specified. In this LOFD-001035
handover
case, onlypriority the blind is
not specified.
handovers to theIn this
case, only the
high-priority blind
system
handovers
are applicable. to the
high- and medium-
priority systems are
applicable.
Indicates the
Location Services LOFD-001033
NO NO No
(LCS) capability of LOFD-001047
Indicates
the UTRAN. the
Location Services LOFD-001034
NO NO No
(LCS) capability of LOFD-001047
Indicates
the GERAN. the
Location Services LOFD-001035
NO NO No
(LCS) capability of LOFD-001047
the CDMA2000.
Indicates the ID of LOFD-001032
the RAT/frequency YES YES No LOFD-001044
priority
Indicates group.DL LOFD-001045
Indicates the the Radio LOFD-001032
EARFCN of an
Access Technology YES YES No LOFD-001044
external
(RAT). E-UTRAN LOFD-001045
cell. For details, see LOFD-001032
3GPP TS 36.101. YES YES No LOFD-001044
Indicates
This parameter the is LOFD-001045
priority
requiredofonly the RAT
when LOFD-001032
or
RatType is setThe
frequency. to NO NO No LOFD-001044
value
LTE. 0 indicates LOFD-001045
the lowestthe
Indicates priority.
index
YES YES No None
of the operator.
Indicates the ID of
the service-based LOFD-001043
Indicates YES YES No
inter-RAT whether
handover LOFD-001046
inter-RAT
policy group. handover
is required,
Indicates whether allowed, LOFD-001043
NO NO No
or not allowed
to use normal or for LOFD-001046
services
Indicates with
the
special DRX. If this the
QCI.
subscriber
parameter is profile
set toID YES YES No None
(SPID).UEs with the
TRUE,
SPID use normal
Indicates the length NO NO No LBFD-002017
DRX parameters. If
of the counter
Indicates the is
this parameter
Indicates whether LOFD-001032
check
COUNT timer.
value Whenfor
setset
to to FALSE,
a RAT orUEsa NO NO No LOFD-001044
the timer
initiating expires,
counter
with the
frequency SPID use
priority. LOFD-001045
counter
check check
specialprocedures.
Indicates DRXthe ID of a LOFD-001032
procedure
When
RAT/frequency is
the COUNT NO NO No LOFD-001044
parameters.
initiated.
value
priority(used After
group. at the
the LOFD-001045
procedure
PDCP layer) is of any
complete,
DRB for a the UE timer
is a NO NO No LBFD-002004
is restarted.
multiple of theThe value
value
of this 0 indicates
parameter,
Indicates whether
that the timer is NO NO No LBFD-002004
the eNodeB
to release a data
invalid.
initiates
radio In
a
bearer this
countercase,
(DRB)
Indicates the
the
check
when eNodeB
procedure.
the cannot
counter NO NO No LBFD-002004
highest-priority
initiate
The
check periodic
value
detects0 an
ciphering algorithm
counter
indicates
Indicates
exception in check
that
the the
supported bythethe LOFD-00101001
procedures.
eNodeB does
second-priority
DRB. not NO NO No
eNodeB. The value LOFD-00101002
initiate
ciphering
NULL counter
algorithm
indicates that
Indicates
check
supported the
procedures third-
bynotthe LOFD-00101001
ciphering
priorityon is
ciphering NO NO No
based
eNodeB.
applied. the value
The LOFD-00101002
algorithm
Indicates
COUNT
NULL supported
the
value.
indicates that
by the eNodeB.
is not The
highest-priority
ciphering LOFD-00101001
NO NO No
value
integrity
applied. NULLprotection LOFD-00101002
Indicates
indicates that
algorithm the
supported
second-priority
ciphering
by is not The
the eNodeB. NO NO No LBFD-002004
integrity
applied.
value NULL protection
algorithm
Indicates
indicates that supported
the third-
by the eNodeB.
priority
integrity integrity
protection The NO NO No LBFD-002004
value NULL
protection
is not applied. algorithm
indicates
supportedthat by the
integrity protection NO NO No LBFD-002004
eNodeB. The value
is not applied.
NULL indicates that
integrity protection
is not applied.
the
to set decompressor,
a logical
Indicates
and a feedback the
channel group
compression
channel profile
profile. is not
supported
mandatory. by the
Currently, two
eNodeB.
Indicates
Therefore, whether
U-Mode
logical channel
Under
Indicates
to
is enable
less the
reliable ROHC
the
or disablethan
group profiles are
framework,
method
SRI of
adaptation.
Bidirectional X2 header setupIf
available:
compression
by
theSON, that
SRI adaptation
Optimistic Mode is, the (O- LBFD-002018
LCG_PROFILE_0
algorithms
method
functionand
Mode) of vary with
is enabled, NO NO No LBFD-00201801
and
protocols.
automatically
the SRI period
Bidirectional Profiles is LBFD-00201802
LCG_PROFILE_1.
define
setting
adjusted
Reliable the
up header
X2
based
Mode on
(R- LBFD-002025
If LCG_PROFILE_0 NO NO No
compression
interfaces.
the
Mode), SRI load
but its in LOFD-001015
is used, only one
protocols
each cell.
feedback-induced (such
If the as
logical
Indicates channelwhether LBFD-002025
RTP/UDP/IP
Indicates
function the or
length
overhead
group
to enable
Indicates is is isdisabled,
assigned
ROHC.
the length NO NO No LOFD-001015
TCP/IP),
of
the timer
minimum SRI which
T302.
period
compared are
to
Set
of non-GBR
thisthe
timer parameter
T320 to be LBFD-002001
under
T302 specifies
(configurable)
with those same
in O- the
for
services.
to ON ifframework,
contained the Ifin
ROHC
wait
each time
QCI for NO NO No LOFD-001017
Mode
LCG_PROFILE_1
eNodeB and
RRCConnectionRel
for specific isisR-Mode.
types
retransmitting
applied.
In O-Mode, an of
is used,
expected
ease
packet
two
messages to the
streams.
logical
support
RRCConnectionRe
decompressor
channel groupscan are
VoIP
sent
Each or
for video
load
profile has a NO NO No LOFD-001017
quest
send
assigned message
feedback to non-
services.
balancing.
unique identifier.T320
after
messages
GBR the previous
services. to the One
specifies
As defined
request the
with by atime
LTE
compressor
Indicates
group is the
assigned to length NO NO No LOFD-001017
period
specifications,duringthan which
cause
indicate
of
to timer other
a
T320
high-priority tothe be
non-
the
eNodeB dedicated
Indicates
"MO-Data" supports
the and length
decompression
contained
GBR services, in and
priorities
the
of following
timer (usedforfor
"MO-Signalling"
failure orT304
RRCConnectionRel
the other agroup is is NO NO No LBFD-002007
cell reselection)
profiles:
intra-RAT
rejected.
Indicates profile
handover.
the length are
successful
ease
assigned messages toT320context
low-
valid.
0x0001
If the
This
of timer After
UE
timer (usage:
T304does
is started fornot
update.
sent
priority for O-Mode
reasons
non-GBR is LBFD-002018
expires,
RTP/UDP/IP;
complete
after
inter-RAT the the
UEthe
handover NO NO No
more
other
services. reliable
than load than LBFD-00201803
dedicated
reference:
handover
receives
to GERAN. an priorities
RFC
beforeIf the
U-Mode
balancing. and T320
become
3095
this and
timer
RRCConnectionRej
UE does invalid.
RFC
expires,
not LBFD-002018
requires athe
specifies smallertime NO NO No
This
4815),
the
ect UEtimer
message.
complete profile
reverts is started
the Itback
is LBFD-00201803
amount
period
Indicates ofthe
during feedback which
length
when
0x0002
to the
stopped
handover the UE
(usage:
associated
whenbefore the
than
the
of R-Mode.
dedicated
the UEreference: inactivity In R- LBFD-002018
receives
UDP/IP;
configuration
UE
this enters
timer an the
expires, and NO NO No
Mode,
priorities
timer. the (used
If detecting reliability for LBFD-00201803
RRCConnectionRel
RFC
initiates 3095
RRC_CONNECTE
the UE an and
reverts RRCRFC
of context
cell
that
ease
4815),
reselection)
a UE
message
profile has back are
connection
D
to mode
the
valid. or
associated
synchronization
After re-
performs
T320 LBFD-002018
neither
containing
0x0003 received
(usage: theand t320 nor NO NO No
establishment
cell
between
expires,reselection.
configuration the
the LBFD-00201803
sent
IE.
ESP/IP; data
It is stopped for
reference: a
procedure.
initiates
compressor
dedicated an RRC
and the
priorities
duration
when
RFC the
3095 exceeding
UE and enters
RFC
connection
decompressor
become
the value invalid. re-
ofprofile
this is NO NO No LBFD-002007
Indicates
the
4815), and the timer
establishment
higher
This
parameter,timerthanis that
thestarted in
governing
RRC_CONNECTE
0x0004 (usage:the IP;
procedure.
any
when
eNodeB other
the mode.
UE
releases
period
D mode.
reference: the eNodeB RFC
Because
receives
Indicates of
anthe NO NO No None
the
will
3843 radio
waitand for RFC a timer
resources
frequent
RRCConnectionRel
governing
for the
response UE. feedback,
the If
message this
4815).
Indicates
however,
ease
period message
the the
R-Mode
eNodeB timer
parameter
Indicates
from the the
UE. is set timer to NO NO No None
governing
causes
containing
will wait the the greatest
the
a t320
forinactivity
0, the
governing UE the
period
linkItoverhead.
IE.
response is the
stopped eNodeB
message
timer
period
Indicates isthenot the used.
eNodeB
will
when wait the for UE a timer
from
will the
wait
governing
response message
MME.
for theenters
a NO NO No None
the
resynchronization
period
from the eNodeB
RRC_CONNECTE
the
indication
will wait
Indicates for message
the a timer
neighboring
D mode. NO NO No None
from
governing theIf the
response the UE.message
eNodeB.
eNodeB
from the
period the and
peer eNodeB ainter-
UE
are
RATwait
will unsynchronized
network for an initial NO NO No None
for
UE the
element.contextfirst time, setupthe
eNodeB
request from the monitors
Indicates
resynchronization the switch NO NO No None
MME.
for adjusting
information
Indicates thefrom the
local PA
the
through
UE within
ID of the cell. Itpowerthe
control
period specifiedonidentifies
the bya YES YES No None
uniquely
PDSCH.
Indicates
cell timer.Ifthe
this within Ifathis
the
BS. PAUE
parameter
fails tothe
when achieve
poweris set to
NO NO No LBFD-002016
ON, thefor
resynchronization
control PAthe is
Indicates the
adjusted
during
PDSCH thisis period,
disabled,
threshold for UEs to
dynamically
the eNodeB
downlink when is
enter DRX in ICIC the NO NO No LBFD-002016
the channel
considers
disabled,
Indicates that
and
the quality
the in
local
cell that operates
is
ID extremely
resynchronization
even of power
the cell. goodIt
FDD mode. This YES YES No None
or
timesbad.out.identifies
distribution
uniquely
threshold isisused usedina
for the
cell DRX
the PDSCH.
withinalgorithm.a BS.
If the traffic volume NO NO No LBFD-002017
at a UE is lower
than this threshold,
the eNodeB
decides that the UE
should retain its
DRX state or enter
DRX.
Indicates the
threshold for UEs to
exit DRX in
Indicates thethe cell
uplink
that operates
traffic volume in
FDD mode.
threshold forThis UEs to
Indicates
threshold
enter DRXthe isinuseduplink
the in
traffic
the DRX volume algorithm.
cell that operates in
threshold
If the mode.
Indicates
TDD traffic forvolume
the UEs to
This NO NO No LBFD-002017
exit
at a DRX
UE istraffic
downlink
threshold in
is the
higher
used cell
in
that
thanDRX
volume
the operates
thisthreshold
threshold,
algorithm. in
Indicates
TDD
the
for mode.
eNodeB
UEs tothe This
enter NO NO No LBFD-002017
If the traffic volume
downlink
threshold
decides
DRX in traffic
is
that
the used
thethat
cell in
UE
at a UE is lower
volume
the
shouldDRX
operates threshold
algorithm.
retain
in TDDits
than this threshold, NO NO No LBFD-002017
for
If UEs
the
non-DRX
mode. tostate
traffic
This exit
volumeDRX
or
the eNodeB
in
at the
a UE
Indicates cell
exit DRX.that
threshold is that
higher
the
is used length in
decides
Indicates whetherthe UE
operates
than
of
the the this
DRX UE intraffic
TDD
threshold,
algorithm. NO NO No LBFD-002017
should
the transmitretain its
power
mode.
the eNodeB
measurement
If the This volume
traffic
DRX
of the state
UE isor enter
threshold
decides
period. is
that used
the UE in
DRX. The
at a UE
adjusted is traffic
lower
the
should
volumeDRX algorithm.
retain
ofthreshold,
a its NO NO No LBFD-002017
than this
according toUE the
If the
non-DRX
during
the traffic
eNodeB thisstate volume
period or is
difference between
at
exita UE
DRX.
measured. is
decidesIndication higher
Based
that the UE
MCSs. is NO NO No LBFD-002017
than
on the
should this threshold,
retain its
contained
Indicates in an
the local
the
DRX eNodeB
measurement
state or enter
RRC
ID of message
the cell. It UE
decides
result,
DRX. the that DRX the YES YES No None
signaled
uniquely to the UE.a
identifies
should retain
algorithm decides its
In
cellthe message,this
within a BS.
non-DRX
whether state or
indicationthe
Indicates the UEpower
occupies
exit DRX.
should
offset of enter
the or exit NO NO No LBFD-002026
one bit. The value
DRX.
sounding
0, which means reference
Indicates
signal to the the power
disabled,
offset of indicates
the NO NO No LBFD-002026
PUSCH
that TFwhen isreference
equal to
sounding
DeltaMcsEnalbed
0 because
signal to the Ks is is
Indicates
set to the alpha NO NO No LBFD-002026
equal
PUSCH to when
0. The
filtering
UU_DISABLE. coefficient
value 1,
DeltaMcsEnalbed which
used by the UE is
means
set to RSRP enabled,
during NO NO No LBFD-002026
indicates
Indicates that
UU_ENABLE. whether TF
measurement
Indicates for
is calculated
bearers tothe local
on
which the
path
ID of loss
the cell. It
condition
the parameter that Ks is YES YES No None
estimation.
uniquely identifies a
equal to
group 1.25.
applies
cell within
Indicates
support DRX. a BS.
the IDTheof
Indicates
the DRX
value ON indicates the
parameter length YES YES No LBFD-002017
of the
group.
that the OnbearersDuration
Timer.The
support DRX. value The of
onDurationTimer NO NO No LBFD-002017
value OFF indicates
delivered
that the bearers to UEsdo is
dependent
not support DRX. A on the
NO NO No LBFD-002017
user-configured
UE can enter the
value
Indicates
DRX mode of this the length
only
parameter
of
whenthe allDRX and the
bearers NO NO No LBFD-002017
interval
running at
Inactivity
Indicates on which
Timer.
the it length
CQIs
support
of are
the DRX reported
DRX. LBFD-002017
periodically. NO NO No
Retransmission LBFD-002005
Timer.
Indicates the length
of a long DRX NO NO No LBFD-002017
cycle.
Indicates whether
short DRX cycles NO NO No LBFD-002017
are enabled. length
Indicates
Indicates the the length
of
of the
a shortDRXDRX Short NO NO No LBFD-002017
Cycle
cycle. Timer. If this
parameter is set to
a large value, the NO NO No LBFD-002017
UE followsthe
Indicates short
local
DRX
ID of cycles
the cell.(ifIt
Indicates
configured) theforIDaof a YES YES No LBFD-001001
uniquely identifies LOFD-001019
the
cell within of
long group
time. a BS. LOFD-001020
common
YES YES No LOFD-001021
parameters related
LOFD-001022
to inter-RAT
LOFD-001023
handover.
hysteresis
meets the entering for inter-
RAT measurement
condition, the UE
eventsnot
does A1sendand A2. a
This parameter is
measurement
used
reporttotoprevent
the
frequent
eNodeB triggering LOFD-001020
of event evaluation
immediately. LOFD-001023
caused by
Instead, theradioUE
Indicates the RSRP NO NO No LOFD-001021
signal fluctuation.
sends a report onlyIn LOFD-001023
threshold for inter- LOFD-001019
this
when way,thethe signal LOFD-001022
RAT measurement LOFD-001022
probability
quality of ping-
continuously NO NO No LOFD-001019
Indicates
event A1. the RSRQ LOFD-001023
pong handovers
meets the entering or LOFD-001020
threshold
When for inter-
theduring LOFD-001019
handover
condition decision the LOFD-001021
RAT
measuredmeasurement RSRP NO NO No LOFD-001020
errors is reduced.
time-to-trigger.
Indicates the RSRP A
event
value A1.
of the serving LOFD-001023
LOFD-001021
larger
This value
parameter
threshold for ofinter-
this
When
cell the
exceeds thisthein LOFD-001019
LOFD-001022
parameter
helps
RAT decrease
measurement results
measured
threshold,
Indicates RSRQ
an
the event
RSRQ NO NO No LOFD-001020
a lower
number
event A2. probability.
of LOFD-001023
value
Indicates
A1 of the
report
threshold forserving
the
may time-
be
inter- LOFD-001021
occasionally
When
cell the
exceeds this LOFD-001019
LOFD-001022
to-trigger
sent.
RAT
triggered
measured for
measurement
Indicates the
event
RSRPevent NO NO No LOFD-001020
threshold,
B1
eventrelated
hysteresisA2. an
for event
toserving
inter-
event LOFD-001023
reports,
value
A1 of
report the
themay be LOFD-001021
RAT
When
B1
cell for
average handover
the
inter-RAT
is below number this to of LOFD-001019
LOFD-001022
sent.
CDMA2000
measured
handover to 1xRTT.
RSRQ NO NO No LOFD-001020
handovers,
threshold, an event and the
When
value
CDMA2000
Indicates
number
A2 reportdetecting
of the
of the 1xRTT.
wrong
may bethat
serving
local LOFD-001021
the
ID ofsignal
cell
This isparameter
below
the
handovers.
sent. quality
cell. It isin
Inthis LOFD-001022
Indicates
at
usedleast
threshold,
to onethe
an
prevent ID
eventof a YES YES No LBFD-001001
uniquely
summary,identifies it helps
the
A2 parameter
neighboring
report
frequent
cell within
prevent may cell
triggering
a BS. be
group
meets
sent.
of event
Indicates
unnecessaryrelated
the entering
evaluation
the to
pilot YES YES No LOFD-001021
inter-RAT
condition,
caused
strength
handovers. by handover
the
radio
threshold UE
to
doesCDMA2000
signal not send
fluctuation.
for event B1 related a In
1xRTT.
measurement
this way, the
to coverage-based NO NO No LOFD-001021
report
probability
inter-RAT to the of ping-
handover
eNodeB
pong
Indicates
to handovers
CDMA2000 the pilotor
immediately.
handover
strength decision
threshold NO NO No LOFD-001021
1xRTT. When the
Instead,
errors
for event
measurementis theB1 UE
reduced. related
value A
sends
larger
to load- a
exceeds this report
value
or of
service- only
this NO NO No LOFD-001021
when
parameter
based
threshold,the signal
aresults in
inter-RAT
quality
a lowercontinuously
handover
measurement probability
to
Indicates
meets thethe entering LOFD-001021
of ping-pong
CDMA2000
report may be1xRTT.sent. NO NO No
extended
condition QoS LOFD-001032
handovers
When theduring or the
class
handover identifier
time-to-trigger.
measurement decision value LOFD-001015
(QCI),
This
errors.
exceeds whichthis is
parameter YES YES No
LOFD-00101502
required
helps
Indicates
threshold,the by
decrease a local the
operators
number
ID of the
measurement of for
cell. user
It
differentiation. YES YES No LBFD-001001
occasionally
uniquely
report
Indicates may identifies
the beID of aa
sent.
triggered
cell withinevent
parameter agroup
BS.
reports,to
related the inter- NO NO No LBFD-00201802
Indicates
average
frequency the ID of
number ofa
parameter
handovers
handover. group
and the
related
numberto ofinter-RAT
wrong NO NO No LOFD-001021
Indicates
handover
handovers, the
to ID of a
parameter
preventing group
CDMA2000 1xRTT.
related
unnecessary to inter-RAT NO NO No LOFD-001021
Indicates
handover the
to ID of a
handovers.
group of common LOFD-001019
CDMA2000 HRPD.
parameters related NO NO No LOFD-001020
Indicates
to inter-RAT the ID of a LOFD-001021
parameter
handover. group
related to inter-RAT NO NO No LOFD-001020
Indicates
handover the to ID of a
parameter
GERAN. group
related to inter-RAT NO NO No LOFD-001019
Indicates
handover the to ID of a
parameter
UTRAN. group
related to intra-RAT NO NO No LBFD-00201801
intra-frequency
Indicates
handover.the ID of a
DRX parameter NO NO No LBFD-002017
group.
Indicates the local
ID of the cell. It
YES YES No LBFD-001001
uniquely identifies a
cell within a BS.
Indicates the QoS
class identifier
(QCI) of an evolved
packet system
(EPS) bearer.
Different QCIs
indicate
Indicatesdifferentthe ID of a LOFD-001015
QoS
parameterrequirements,
group YES YES No
LOFD-00101502
such astothe
related packet
inter-
delay budget,
frequency
packet error loss NO NO No LBFD-00201802
handover.
Indicates For
the ID of a
rate,
details,
parameterand seeresource
the
group
type. For to details,
InterFreqHoGroup
related inter-RAT NO NO No LOFD-001021
see Table
Indicates
handover the
MO. 6.1.7
to ID in of a
3GPP
parameter TS
CDMA2000 1xRTT. 23.203.
group
related to inter-RAT NO NO No LOFD-001021
Indicates
handover the to ID of a
group
CDMA2000 of common HRPD. LOFD-001019
parameters related NO NO No LOFD-001020
Indicates
to inter-RAT the ID of a LOFD-001021
parameter
handover. group
related to inter-RAT NO NO No LOFD-001020
Indicates
handover the to ID of a
parameter
GERAN. group
related to inter-RAT NO NO No LOFD-001019
Indicates
handover the to ID of a
parameter
UTRAN. group
related to intra-RAT NO NO No LBFD-00201801
intra-frequency
Indicates the
Indicates
handover. the time-
ID of a
to-trigger
Indicates
DRX parameter for
the event NO NO No LBFD-002017
B1 related for
hysteresis
group. to inter-
event
RAT handover
B1 related to
to inter-
Indicates
CDMA2000 theHRPD.
SRI LBFD-002025
RAT handover to NO NO No
cycle.
When detecting that LOFD-001015
CDMA2000
Indicates theHRPD.
local
the
ID of the cell. It in
This signal
parameter quality is
Indicates
at
usedleast to one the ID of a
prevent YES YES No LBFD-001001
uniquely identifies
the
cell parameter
neighboring
frequent
withintriggering cell
a BS.
Indicates
group
meets
of event the the
related pilot
to
entering
evaluation
strength threshold YES YES No LOFD-001021
inter-RAT
condition,
caused by radio handover
the UE
for event
to CDMA2000
does
signal not B1 related
send
fluctuation. a In
to load-
HRPD. way,orthe
measurement
this service- NO NO No LOFD-001021
based
report
probability inter-RAT
to the of ping-
handover
eNodeB
pong handovers
Indicates to pilotor
the
CDMA2000
immediately.
handoverthreshold
strength HRPD.
decision NO NO No LOFD-001021
When
Instead,
Indicates
errors
for event thethe
is theUE
reduced.
B1 time-A
related
Indicates
measurement
sends
to-trigger
larger a or
value theof
report
for value
eventonly
this
to load- service- NO NO No LOFD-001021
hysteresis
exceeds
when
B1 the
related
parameter thisfor
signal event
to inter-in
results
based inter-RAT
B1
RAT related
threshold,
quality
a lower ato inter-
continuously
handover
probability to
handover to
RAT
meets
GERAN. handover
measurement the entering
When to LOFD-001021
of ping-pongHRPD.
CDMA2000 NO NO No
GERAN.
report
Indicates may This be sent. LOFD-001032
condition
detecting
handovers
When
Indicates thetheduring
that
the thethe
or local
parameter
received
time-to-trigger.
signal
handover quality is used
signal in
decision at
measurement
ID of the cell. Itvalue
to prevent
strength
This
least
errors. oneindicator
parameter frequent YES YES No LBFD-001001
exceeds
uniquely
Indicates this
identifies
the ID offor a
triggering
(RSSI)
helps
neighboring of cell
threshold
decrease event the
threshold,
cell
the within
parameter a BS.
evaluation
event
number
meets B1
the causedto
ofrelated
entering LOFD-001020
measurement
group related to YES YES No
by radio
coverage-based
occasionally
condition, signal
the LOFD-001023
report
inter-RAT be UE
mayhandover sent.
fluctuation.
inter-RAT
triggered
does not sendeventthis
In
handover a
to GERAN. LOFD-001020
way,
to thethe
GERAN.
reports,
measurement probability
NO NO No LOFD-001023
of
A ping-pong
UE
average
report sends the a
to number of LOFD-001046
handovers
handovers or
measurement
eNodeB and the
handover
Indicates decision LOFD-001020
report
number
immediately. ofthe
related RSSI
wrongto NO NO No
LOFD-001023
errors
threshold
event
handovers,
Instead, is
B1 reduced.
for
to
the UE event
the
The
B1
eNodeB value
related
preventing whenof
to this
load-
the LOFD-001020
sends a report only
parameter
or
RSSIservice-based
in has aone NO NO No LOFD-001023
unnecessary
when theatsignal
least
negative
inter-RAT
GERAN
handovers. correlation
handover
cell LOFD-001046
quality always LOFD-001020
with
to the
GERAN.
exceeds
meets probability
thethisentering NO NO No LOFD-001032
of
Whenping-pong
threshold
condition theduring
and other the
Indicates the LOFD-001046
handovers
measured
triggering
time-to-trigger. or local
RSSI
ID of the
handover
value cell.
exceeds Itthis
decision
conditions
This parameter are met. YES YES No LBFD-001001
uniquely
errors.
threshold, identifies
a a
For details,
helps decrease see the
cell within
measurement a BS.
3GPP TS
number of36.331.
report
occasionallymay be sent.
triggered event
reports, the
average number of
handovers and the
number of wrong
Ec/No of the target
Indicates the time-
UTRAN cell. For a
to-trigger for event
cell with large signal
B1 related to inter-
fading variance, set
RAT handover to
this parameter
Indicates the to a
UTRAN.
Indicates When
the RSCP
large
Indicates value to
threshold the
hysteresis
detecting
Indicates
prevent
that
for
the ID
foreventtheof
event
Ec/No
the
B1
signal
B1 parameter
related
threshold quality
related for to
to inter-
in at
event
unnecessary LOFD-001019
group
RAT
least
B1 related
handover
one
coverage-based
related toFor toto
load- YES YES No
handovers. a LOFD-001022
inter-RAT
UTRAN.
neighboring
inter-RAT
or service-based handover
This cell
handover
cell
to with
UTRAN.
parameter small is used
meets
to UTRAN.
inter-RAT the handover
entering LOFD-001019
signal
to prevent fading frequent NO NO No
condition,
This
to parameter
UTRAN. the UE LOFD-001022
variance,
triggering set
of eventthis
does
specifies
This not send
parameter the a
parameter
evaluation to a
caused LOFD-001019
measurement
requirement
specifies the for NO NO No
small
by radio valuesignal to LOFD-001022
report
RSCP
requirement to
of the
the for target
ensure
fluctuation. timely Intarget
this LOFD-001019
eNodeB
UTRAN
Ec/No ofcell.
the
handovers.
way,
Indicatesthe the A RSCP
probabilitylarger NO NO No LOFD-001022
immediately.
When
UTRAN thecell. When
value
of of
ping-pong
threshold this
forUE event LOFD-001043
Instead,
Indicates
measurement
the the
measurement the time-
value
parameter
handovers
B1 related results
orinter-
to load- in LOFD-001019
sends
to-trigger
exceeds
value a report
for
this
exceeds only
this
a lower
handover
or probability
service-based decision NO NO No LOFD-001022
when
frequency
threshold, the signala to the
of handover
errors
inter-RAT is reduced.
handover A LOFD-001043
LOFD-001019
quality
measurement continuously event
UTRAN
larger
to UTRAN. cell,of
value and thisa LOFD-001032
meets
A1
reportor the
A2.
may entering
beleads sent. NO NO No
smaller
parameter
This value
parameter results in LOFD-00104301
condition
When
For ahigher
cell during
detecting
with the
that
large LOFD-001019
to
a a
lower
specifies
Indicates probability
the
the LOFD-001043
time-to-trigger.
the
signal signal
fading quality in LOFD-001032
probability.
of ping-pong
requirement
hysteresis for for inter- NO NO No
This
the parameter
serving
variance, set cellthis LOFD-00104301
When
handovers
RSCP
frequency the
of the or target
helps
Indicates
meets
parameter decreasethe
the triggering local
to avalue the LOFD-001043
measurement
handover
UTRAN
measurement cell.decision
number
ID of the
condition,
large valueofcell.
theto It
UE
exceeds
Indicates this
the
andIDA2. YES YES No LBFD-001001
errors.
When
events
occasionally
uniquely
does
prevent
threshold,
the
not A1identifies
send
a a of a
the
cell parameter
measurement
This parameter
triggered
withinevent
measurement a BS.is value
unnecessary
measurement
group
exceeds
used torelated
reports,tothe
report this
prevent
thebe to
handovers.
report may Forsent.a YES YES No LBFD-00201802
intra-RAT
threshold,
frequent
average inter-
a
triggering
cell with small of
eNodeB number
frequency
measurement
of event
handovers
immediately. evaluation
and the
signal fading
handover.
report
caused
number
Instead, mayby
of
the be
radio
wrong
UE sent. NO NO No LBFD-00201802
variance,
Indicates the set this
RSRP
signal
handovers,
sends
parameter
threshold fluctuation.
a report
for a only
to inter- In
this
small way,
preventing
when
frequency the
the signal
value to
probability
Indicates
unnecessary the of ping-
RSRQ NO NO No LBFD-00201802
quality
ensure continuously
measurement timely event
pong
threshold
handovers.
meets
handovers.
A1. handovers
the for inter-
entering or
handover
frequency
condition
When decision
during
thethe RSRP the NO NO No LBFD-00201802
Indicates
errors
measurement
Indicates is reduced.
the event
time- A
time-to-trigger.
measured RSRP This
threshold
larger
A1.
to-trigger value for
for inter-
of
eventthis
parameter
value exceeds helps this
frequency
parameter
When
A4 for thethe results
inter- in NO NO No LBFD-00201802
decrease
threshold,
Indicates
Indicates the
a
the eventRSRQ
measurement
a lower
measured
frequency probability.
RSRQ
number
measurement
threshold
hysteresis of forforinter-
event
A2.
value
handover. exceeds When this
occasionally
report
frequency
A4. This may be
parameter sent.
When
threshold,
detecting the that a the NO NO No LBFD-00201802
triggered
measurement
is event
used to prevent event
measured
measurement
signal quality RSRP in at
reports,
A2.
frequent the
triggering
value
Indicates
report
least is
onemaybelow
the RSRP
be sent.the
average
When
of event number
theevaluation of NO NO No LBFD-00201802
threshold,
threshold
neighboring a
for event
cell the
handovers,
measured
caused by and
RSRQ
radio
measurement
A4
meets relatedthe to
entering
number
value
Indicates is of
below
thewrong thisIn
signal
report
condition,
fluctuation.
may
coverage-based thebeRSRQUEsent. NO NO No LBFD-00201802
handovers.
threshold,
threshold
this way, a
for
the Inevent
inter-frequency
does
summary, not send itof a
measurement
A4 related
probability
handover. tohelps
When ping-
measurement
prevent
report may
coverage-based be sent.
pong
the handovers or
measured NO NO No LBFD-00201802
report
unnecessary to the
inter-frequency
handover
RSRP value decision
eNodeB
handovers.
Indicates
handover. the
When RSRP
errors
exceeds is reduced.
this A
immediately.
threshold
the measured for event NO NO No LBFD-00201802
larger
threshold, value an ofinter-
this
Instead,
A4
RSRQ related thetoUE
value load-in
parameter
frequency
Indicates the results
RSRQ
sends
or a
frequency-
exceeds report
this only
a lower probability.
measurement
threshold for event
when the
priority-based
threshold, signal
an inter-
inter- NO NO No LBFD-00201802
report
A4 may
related
quality beload-
to
continuously sent.
frequency
or frequency-
meets
handover. the entering
When
measurement
Indicates the RSRP NO NO No LOFD-001032
priority-based
condition
the measured during inter-
the
report
threshold may for be sent.
frequency
time-to-trigger.
RSRP value
frequency-priority-
handover. When
This
exceeds parameter
Indicates this
the RSRQ NO NO No LOFD-001032
based
the inter-
measured
helps
threshold,
threshold decrease an inter-
for the
frequency
RSRQ
numbervalue
frequency of
frequency-priority-
measurement
exceeds this event
occasionally
measurement
based inter- NO NO No LBFD-00201802
A1. When
threshold, the
an
triggered
report
frequency
measured may event beinter-
RSRP sent.
frequency
reports,
measurement the event
value exceeds this
measurement NO NO No LBFD-00201802
average
A1. Whennumber theevent of
threshold,
report mayan be
handovers,
measured andsent.
RSRQ the
A1 report may be
number
value of wrong
sent. exceeds this
handovers.
threshold, an Inevent
summary,
A1 report may it helps be
prevent
sent.
unnecessary
handovers.
handover. This
parameter
determines the
border between the
serving cell and the
neighboring
Indicates thecell.RSRP If
the parameter
threshold for event is set
to
A1aassociated
large value, with an
Indicates
inter-frequency
event-A3-triggered the RSRP NO NO No LBFD-00201802
Indicates
handover the
threshold
inter-frequency for time-
is event
to-trigger
A2
performed onlywith
associated
handover. for event
A3 associated
event-A3-triggered
when the signalwith NO NO No LBFD-00201802
When
Indicates thethe
intra-frequency
inter-frequency
quality
measured RSRP of the
hysteresis
handover. for event
neighboring
value
A3 exceeds
associated cellwith is
this NO NO No LBFD-00201802
When
significantly
threshold, detecting
the a better that
intra-frequency
Indicates
the signal the local
offset
measured
than that ofquality
measurement
handover.
RSRP
the
This
in
ID
for
the
valueof
eventthe
serving
is cell.
A3
below cell Ittheand
serving
report
parameter maycellis and
be sent.a
used YES YES No LBFD-001001
uniquely
associated
Indicates
that at identifies
intriggering
threshold, awith
the
least IDone of
other
to prevent frequent
cell within a BS.
intra-frequency
the parameter
neighboring
measurement cell
conditions
triggering ofareeventmet.
handover.
group
meet
report
For related
the
may
details, Ifbethe
entering
see to
sent. YES YES No LBFD-00201801
evaluation
parameter
intra-frequency
condition, due
is
the set
UE toto
3GPP
radio TS
signal 36.331.
a large
handover.
does value,
not send a an LBFD-00201801
fluctuations.
intra-frequency
measurement In this NO NO No
Indicates the name LOFD-001032
way,
handover
report theto probability
is
the
of
of the operator. The
ping-pong
performed
eNodeB only
name
handovers is a string
or of NO NO No LBFD-00201801
when the signal
immediately.
a maximum
handover of 32
decision
quality
Instead, ofthethe UE
characters.
errors is The
reduced.
neighboring
sends a report cellonly isA NO NO No LBFD-00201801
string cannot
larger value ofbe this
significantly
when the signalbetter
null characters
parameter results or in
than
quality
Indicatesthat of
thethe
continuously index LOFD-001036
contain
a lowerthe any of
probability. the YES YES No
serving
meets
Indicates cell
of the operator. the and
entering
type LOFD-001037
following
For details, see The
other
condition
of the triggering
during
operator. the
characters:
3GPP TScan comma
36.331.
conditions
time-to-trigger.
operator arebe met.the
(,), semicolon (;), NO YES No None
For
This details, see or
equalparameter
primary
Indicates signoperator
the(=),mobile
3GPP
helps
a secondary
country TS
decrease 36.331.
code (MCC) the
double quotation LOFD-001036
number
operator.
of
markthe("), of For
operator. each
single The NO YES No
Indicates the mobile LOFD-001037
occasionally
eNodeB,
value
quotation of this only
markone ('),
network
triggered
primary
parameter code
event
operator
two or moreis a NO YES No None
(MNC)
reports,
but
stringmore offor
the the one
than
three
spaces, two or
operator.
average
secondary
characters, The
number value
operator
each of
of
more percent signs
of
can this
handovers,
which be parameter and
configured.
must be (++ a is
the
(%), start sign NO YES No None
a string
number
Indicates
digit in the of
ofthetwo or
incorrect
range
+), and end sign (---
three
handovers,
tracking
from 0 characters,
toarea
9. ID,
END). LOFD-001036
each
whichofuniquely
preventing which must YES YES No
be a digit athe
Indicates
unnecessary intracking
the LOFD-001037
identifies
range
Indicates the 9.
tracking
handovers.
area. of 0
area to code
index LOFD-001036
(TAC), which is NO YES No
of the operator. LOFD-001037
used by the EPC to
determine the area LOFD-001036
Indicates whether NO YES No
within which paging LOFD-001037
the operator
messages are sent.
Indicates
supports
One tracking the areaindex LOFD-001036
YES YES No
of the operator.
emergency
is comprised calls.
of one It LOFD-001037
is
or recommended
more cells.
that this parameter
Indicates whether NO NO No LBFD-002028
be
theset to a value in
operator
accordance
supports thewith the
Indicates
actual emergency NO NO No LBFD-002028
emergency
Allocation andcalls
call capability
initiated by
Retention Priority UEs of in the
operator.
limited
(ARP) value mode.
Indicates theof the NO NO No LBFD-002028
dedicated
Allocation and
emergency
Retention Priority call
bearer.value of the NO NO No LBFD-002028
(ARP)
default
Indicates emergency
the
call bearer. LOFD-001036
eNodeB sharing NO NO No
LOFD-001037
mode.
Indicates the index LOFD-001036
YES YES No
of the operator. LOFD-001037
Indicates the
proportion of the
maximum number
of users for the
operator at the LOFD-001036
shared eNodeB. NO YES No LOFD-001037
This parameter
Indicates the LBFD-004014
must be set
minimum length of
according NO NO No None
the S1 re- to the
Indicates
contract
establishment the timer.
signed by LOFD-001018
maximum
the operators. length of
NO NO No LOFD-001036
the S1 re-
LOFD-001037
establishment timer.
Indicates the ID of
Indicates the ID of YES YES No LOFD-001018
the S1 interface.
the Stream Control
Transmission
NO YES No None
Protocol (SCTP)
link over the S1 LOFD-001018
Indicates
interface. the
Indicates the index NO YES No LOFD-001036
of the operator.
compliance protocol LOFD-001037
release of the MME
LBFD-001001
to which the NO NO No
LBFD-001007
eNodeB is
Indicates
connectedwhether through
the
the S1S1 interface
interface.is NO NO No None
blocked.
Indicates the status
NO NO Yes None
of the S1 interface.
Indicates the status
of the SCTP link on NO NO Yes None
the S1 interface.
Indicates whether
the MME connected
NO NO Yes LOFD-001018
to the eNodeB is
Indicates
overloaded. the
number of users
NO NO Yes None
that have the
Indicates accessed
the S1 interface.
number of streams
supported
Indicates the by name
the NO NO Yes None
Indicates
SCTP
Indicates
of the
linkthe
the MME IDs
the of
ontoGlobal
all
S1 served
interface.
Unique
which MME
the PLMNs of
eNodeB
the MMEs to which
Identifiers NO NO Yes None
is connected
the eNodeB
(GUMMEIs)
through the S1 is all
of LOFD-001018
connected.
MMEs
interface.to whichThe ID
the NO NO Yes LOFD-001036
of a served
eNodeB is PLMN LOFD-001037
consists
connected.
Indicates ofthethe
A loadMCC
and
GUMMEI
of MNC. PLMN
of a
the connected NO NO Yes None
IDs are
serving
MME separated
MME to that
relative
by commas
consists
of other of the
MMEs. (,). A
MCC, MNC, MME NO NO Yes None
larger value of this
group ID, and
parameter MME
indicates LBFD-002018
Indicates
code.
a larger the ID of
GUMMEIs
capacity
Indicates the ID of YES YES No LBFD-00201801
the
are X2 interface.
separated
allowing UEControl by
access.
the Stream LBFD-00201802
commas (,).
Transmission
NO YES No None
Protocol
Indicates(SCTP)whether
link
the over the
automatic
Indicates the X2
Indicates
interface.
removal ofthe
the index
X2 LOFD-001036
compliance protocol NO YES No
of the
Indicates
interfaceoperator.
the
is ID of
allowed. LOFD-001037
release
the of the
neighboring
If the peer eNodeB
neighboring LBFD-001001
eNodeB
is removed to which
by NO NO No
eNodeB
the to
localthe which
eNodeB LBFD-001007
running
the local eNodeBRMV is is
connected
X2ENODEB through
connected
the through
X2 interface. NO NO No None
command,
the X2 the local
interface.
The
eNodeB combination
determines of
this parameter
whether to and
NO NO Yes None
NbrEnbPlmnId
automatically
(PLMN
remove ID theofX2 the
neighboring
interface based on
eNodeB)
the settinguniquely
of this
identifies
parameter. the
neighboring
eNodeB around the
globe.
Indicates the PLMN
ID of the
neighboring
eNodeB to which NO NO Yes None
the local eNodeB is
connected
Indicates
Indicates the the through
status
DRX
the X2 interface. NO NO Yes None
of the X2 interface.
switch. The value
ON indicates that
DRX is enabled,
Indicates whether NO NO No LBFD-002017
and
to the value
enable OFF
or disable
Indicates
indicates
short DRXthatthe length
DRX
cycles.
of a long
is disabled. DRX cycle NO NO No LBFD-002017
Short DRX cycles
that is
Indicates applied
the
reduce the traffic only
length
to
of non-power-
the
delay. On Duration NO NO No LBFD-002017
savingthat
Timer UEsiswhose
Indicates
RFSP
appliedindexes thetolength
only are
non-
of the
contained DRX
power-saving UEs in the NO NO No LBFD-002017
Inactivity
RFSP index
whose RFSPTimer set.that
is appliedare
Indicates
indexes only to
whether
non-power-saving
to enable or
contained in disable
the NO NO No LBFD-002017
UEs
RFSPwhose
short DRX
indexcyclesRFSP
set.
Indicates
indexes
for non-power- the length
are
of a short
contained DRX
inwhose
the NO NO No LBFD-002017
saving UEs
cycle
RFSP
Indicatesthat
index
RFSP indexes is applied
the set.
length
are
only
of the to non-power-
DRX
contained in the Short NO NO No LBFD-002017
saving
Cycle
RFSP Timer UEs whose
index that
set. is
RFSP
appliedindexes
only to are non-
Indicates
contained
power-saving thein the UEs NO NO No LBFD-002017
extended
RFSP index
whose RFSP QoS set.
Class
indexes Identifier
are LOFD-001015
(QCI),
Indicates
contained whichthe is
in the YES YES No
LOFD-00101502
required
preallocation
Indicates
RFSP index set.by
the the
operatorThe
weight.
service for user
type LOFD-001015
Indicates
differentiation.
preallocation the weight
weight NO NO No
corresponding to LOFD-00101502
factor
of used
theaextended
UE is the QCI. in the
calculation of weight
preallocation LOFD-001015
Indicates the weight NO NO No
connection
of services carried priorities LOFD-00101502
factor
during used
uplink in the
on the highest-
calculation
scheduling. of LOFD-001015
priority logical NO NO No
connection priorities LOFD-00101502
channel.
Indicates Iftheservices
uplink
during downlink
carried
minimum on highest- LBFD-002025
scheduling. NO NO No
priority
guaranteed logical bit rate LOFD-001015
Indicates
channels
of the service. the
have
downlink
different minimum LBFD-002025
LOFD-001019
NO NO No
guaranteed
preallocationbit rate LOFD-001015
LOFD-001020
Indicates
of the service. the
weights,
Indicates the UE LOFD-001021
priority of the LBFD-002025
takes the largest
prioritized bit rate of NO NO No LOFD-001022
related logical LOFD-001015
value
Indicatesof the the ID
the related
channel. The UEof
logical LOFD-001023
preallocation
an inter-RAT
channel. The UE LOFD-001043
scheduler NO NO No
weights.
handover
scheduler Thepolicy LOFD-001045
guarantees
preallocation
group.
guarantees LOFD-001044
prioritized bit rates LBFD-002025
opportunity
prioritized bithas a
rates NO NO No LOFD-001046
of logical channels LOFD-001015
positive
of descending correlation
logical channels LOFD-001033
in order
with the
in descending order LOFD-001034
of logical channel LBFD-002025
preallocation
of logicalResources
channel NO NO No LOFD-001035
priority. LOFD-001015
weight.
priority. When
For details,
are allocated
Indicates the in of
ID
resources
see 3GPP are
TS LBFD-002001
descending
an RLC/PDCP order of NO NO No LOFD-001019
insufficient,
36.321. LBFD-002008
logical
parameter
Indicates channel group.
whether LOFD-001020
preallocation
priority
the after the
extended LOFD-001021
weights affectQCI the is NO NO No
LBFD-002025
prioritized
specific to bit
free rates LOFD-001022
LOFD-001015
preallocation
of all services
Indicates
users the ID
or paid areof
users. LOFD-001023
opportunities of
guaranteed.
the inter-RAT For LOFD-001043
users. YES YES No
details, see
handover 3GPP
policy LOFD-001045
TS 36.321.
group. LOFD-001044
LOFD-001046
LOFD-001033
LOFD-001034
LOFD-001035
perform
GERAN the
GPRS PS
PS_HO:
handover Indicates
to the
EDGE
Indicates
the cell.
switch the
used switchto
UTRAN
CCO_HO: cell.Indicates
used
enable
If this to orenable
switch disable or
is set
the
the switch
disable theUE
QCI-specific used
single to
PS
to Off,
enable the
or disable
radio
handover
cannot voice to
perform call the
the QCI-specific
continuity
CDMA2000 (SRVCC)
HRPD.
PS
Cell handover
Change to the
Order
handover
If this
UTRAN switch to
cell. is set LOFD-001022
(CCO)
GERAN
to On, handover
the GSM.UE can to NO NO No
SRVCC:
Indicates
GERAN Indicates
the switch
GPRS LOFD-001019
If
thethis
perform
used switch
switch theused
to enable is
PS or set
to
EDGE.
to On, the
handover UEthe
to can
enable
disable
If or
this switch disable
QCI-specific
is set NO NO No LOFD-001023
perform
CDMA2000
the
SRVCC the
QCI-specific
to UE SRVCC
HRPD
to On,
handover
cell. the to 1xRTT.
the can
SRVCC
CDMA2000
perform handover
the CCO
GERAN
If
to
If this
UTRAN.
this GSMis
switch
switch iscell.
set NO NO No LOFD-001020
handover
If
to this
Off,switch
the to
UE the
is set
If this
turned
GERAN switch
on,GPRSUEs is set
can
to
to Off,
cannot
On,
perform the
perform
theSRVCCUE
UE canthe
to
EDGE
cannot
PS cell.
perform
handover to the
the NO NO No LOFD-001019
LOFD-001021
perform
CDMA2000
If this switchthe SRVCC
1xRTT
is set LOFD-001020
SRVCC
CDMA2000
handover
cells. handover
to HRPD
the
to
to Off, the
the switch
GERAN UE LOFD-001021
cell.
UTRAN
If this
cannot cell. is GSM
perform the NO NO No LOFD-001021
LOFD-001022
cell.
OMT_HO:
Indicates
If this
turned
Indicates switch
off, Indicates
whether
UEs
whetheris set
CCO
the handover
switch used toto LOFD-001023
to permit
Off,
cannot
to the
prohibit orUE
performorforbid
allow
the
enableGERAN or GPRS
disable LOFD-001043
the
cannot
SRVCC
fast inter-RAT
perform
to
Automatic the NO NO No
EDGE
the cell.
QCI-specific LOFD-001045
handover
SRVCC
CDMA2000
Neighbor under
handover
1xRTT
Relation the
NACC_CCO_HO:
OMT handover to LOFD-001044
QCI.
to the UTRAN
cells.
(ANR) in the cell.
group. LOFD-002001
Indicates
CDMA2000 theHRPD.switch NO NO No LOFD-001046
This
used policy
to enableis or LOFD-002002
LOFD-001033
If this switch
reserved for is set
future
Indicates
disable the the QCI-ID of LOFD-001034
to
use On, the
and NACC- UE
therefore can is LBFD-002001
the RLC/PDCP
specific YES YES No LOFD-001035
perform
Indicates
not the
supported the OMTUE-
intothe LBFD-002008
parameter
CCO handover group.
handover
specific
Indicates
current to the
maximum
the
release. length
GERAN
Indicates
CDMA2000
number GPRS
of whether
RLCHRPD LBFD-002001
of the PDCP
EDGE. NO NO No
Indicates
to use
cell.
ARQ the the LBFD-002008
discard
If timer.
If this
this switch
switch is
eNodeB-specific
acknowledged
retransmissions, is set
set LBFD-002001
to On,
maximum
mode
to Off,
that the
is,(AM)
the
the UE UEor can
number NO NO No
perform
of the
RLC perform
ARQ NACC- LBFD-002008
unacknowledged
cannot
maximum number the
CCO
OMT
of AM handover
retransmissions,
mode (UM)
handover
PDU at to
the
to LBFD-002001
Indicates
the
that GERAN
is, thetheGPRS UE- NO NO No
RLC
the layer.
CDMA2000
retransmissions. LBFD-002008
specific
EDGE
maximum threshold
cell. number
HRPD
When
for cell.
the
theswitch
data number
Indicates
If
of this
AM PDU thevolume
is set LBFD-002001
of
of retransmissions
PDUs toUE trigger NO NO No
eNodeB-specific
to Off, the
retransmissions. LBFD-002008
reaches
polling. the value
When the
threshold
cannot
When for
perform
the numberthe the
of this
transmittedparameter,data LBFD-002001
data
NACC-CCO
of volume
retransmissions
Indicates the of
UE- NO NO No
RRC
volume connection
PDUs
handover
reaches
specific toreaches
trigger
theto value
thresholdthe is the LBFD-002008
reestablishment
value of this
polling.
GERAN
of
for this
the
Indicates When
GPRS
parameter,
number
the the
of
initiated.
parameter, the LBFD-002001
transmitted
EDGE
RRC
PDUs cell.
connection
to
eNodeB-specific data
trigger NO NO No
polling flag is set in LBFD-002008
volume
polling.
threshold reaches
reestablishment
When for the theisthe
the
value PDU of
transmitted header
this
initiated.of PDUs number to LBFD-002001
number to NO NO No
trigger
parameter,
of PDUs polling. the
reaches LBFD-002008
trigger polling.
polling
the
When value flagofisthis
the set in
the PDU
parameter, header
the to LBFD-002001
transmitted number NO NO No
trigger
polling polling.
flag is set in LBFD-002008
of PDUs reaches
Indicates the length
the
the PDU
value header
of the polling PDUof this to LBFD-002001
trigger
parameter, polling. thelength NO NO No
retransmission
Indicates the LBFD-002008
polling
timer forflag
of the polling the isUE. set in
PDU
the LBFD-002001
retransmission to
PDU
Indicate header
the length NO NO No
trigger
of thefor polling.
UE-specific LBFD-002008
timer the
timer
Indicate for
eNodeB.the prohibiting
length LBFD-002001
status reporting
of the eNodeB- NO NO No
LBFD-002008
from thetimer
specific receiver for in
acknowledged
prohibiting status LBFD-002001
Indicates
mode. the length NO NO No
reporting from the LBFD-002008
of the UE-specific
receiver in
timer
Indicatesfor reordering
acknowledged the length LBFD-002001
NO NO No
at
of the
the receiver
mode. eNodeB-in LBFD-002008
acknowledged
specific timer for
mode. LBFD-002001
reorderingthe
Indicates at thelength NO NO No
LBFD-002008
receiver
of a PDCP in
acknowledged
sequence number LBFD-002001
mode. NO NO No
of a UL DRB in LBFD-002008
unacknowledged
mode.
Indicates the length
of a UL RLC
sequence number
in unacknowledged
mode. In
V100R003C00, if
UlRlcSnSize and
DlRlcSnSize are set
LBFD-002001
to differentthe
Indicates values,
length NO NO No
LBFD-002008
theavalue
of DL RLC of
DlRlcSnSize
sequence number LBFD-002001
Indicates
prevails. the
The length
RLC is NO NO No
in UM. The length LBFD-002008
of the
sequence UE-specific
permanently 10 bits number
timer
in AM.for
length
Indicates is reordering
the length LBFD-002001
NO NO No
at the eNodeB-
permanently receiver inbits LBFD-002008
Indicates the 10
of the QoS
unacknowledged
in acknowledged
specific timer for
class identifier LBFD-002001
mode.
reordering
Indicates atevolved
whether the a NO NO No
(QCI) of an LBFD-002008
receiver
PDCP status
packet in report
system
unacknowledged
is required
(EPS) bearer. upon LBFD-002001
Indicates
mode. the NO NO No
handoverQCIs
Different in LBFD-002008
preallocation
acknowledged
indicate
weight. different
The
mode. LOFD-001015
QoS
Indicatesrequirements,
preallocation the weight
weight YES YES No
LOFD-00101502
such
factor as the
of a UE is the the
used packet
in
delay
calculationbudget,
preallocation of weight LOFD-001015
Indicates
packet error the weight
loss NO NO No
connection
of services priorities
carried LOFD-00101502
factor
rate,
during andused
uplink in the
resource
on the highest-
calculation
type. For
scheduling. of
details, LOFD-001015
priority logical NO NO No
connection
see Table priorities
6.1.7 in LOFD-00101502
channel.
Indicates Iftheservices
uplink
during TS
3GPP downlink23.203.
carried
minimum on highest- LBFD-002025
scheduling. NO NO No
priority logical
guaranteed bit rate LOFD-001015
Indicates
channels
of the service. the
have
downlink
different minimum LBFD-002025
LOFD-001019
NO NO No
guaranteed
preallocationbit rate LOFD-001015
LOFD-001020
of the service.
weights,
Indicates the
theUE type LOFD-001021
LBFD-002025
takes
of the largest
adaptive MIMO NO NO No LOFD-001022
LOFD-001015
value
for of the
a multi-antenna
Indicates the ID of LOFD-001023
preallocation
Indicates
eNodeB.
an of The
inter-RAT
priority the
the LOFD-001043
weights.are
prioritized
values The bit rate of NO NO No
handover
related logicalpolicy LOFD-001045
preallocation
the related
described
group.
channel.
Indicates The as
the logical
UEof
ID LOFD-001044
opportunity
channel.
follows:
scheduler The has UEa LBFD-002025
LOFD-001046
an RLC/PDCP
Indicates the fixed NO NO No
positive
scheduler
NO_ADAPTIVE:
guarantees correlation A LOFD-001015
LOFD-001033
parameter
MIMO mode group.
for a is
with the
guarantees
fixed MIMO
prioritized bitmoderates LOFD-001034
multi-antenna LBFD-002025
preallocation
prioritized
used.
of bit
Thatchannels
logical
Indicates the is,rates NO NO No LOFD-001035
eNodeB. This LOFD-001015
weight.
of
in logical
transition
descending
measurement Whenchannels
between order
gap
parameter
resources
in is valid
are
of descending
MIMO logical
Indicates
pattern. modes channel
the order
is not LOFD-001015
only
of whenchannel
insufficient,
logical
supported. NO NO No
priority.
default
The eNodeB Resources
level of LOFD-00101502
MimoAdaptiveSwitc
preallocation
priority.
OL_ADAPTIVE: For details,
are
Doppler
definesallocated shift
the in is
that
h is set
weights to
see
applied 3GPP
open-loop
descending
measurement
NO_ADAPTIVE. when the
affect TS
adaptive
order gaps of NO NO No LOFD-00101502
preallocation
36.321.
MIMO
logical
measurement
for UEsare mode.
channel
in four UEs
There
opportunities
report RANK of
and
priority
switches
connected
Indicates afterare
the the
mode.turned
upper- LOFD-001001
values.
users.
CQI values but do NO NO No
prioritized
off.
During
layer the
filtering bit rates LOFD-001003
TM2:
not Transmission
report PMI
of all services
measurement
coefficient are
for gaps,
mode
values 2toisthe
guaranteed.
Indicates
a UE
RSRP measures theFor upper- the LOFD-001001
permanently
eNodeB. NO NO No LBFD-00201802
details,
layer
signal see
filtering
measurementsquality 3GPP
ofon the LOFD-001003
applied
CL_ADAPTIVE: to UEs. LOFD-001019
TS
cells 36.321.
coefficient
E-UTRAN. on a for
specific
TM3: Transmission
closed-loop LOFD-001020
RSRQ
frequency.
Indicates
A larger the L3
value of NO NO No
mode
adaptive 3 is MIMO LOFD-001021
measurements
There
filtering
this are two gap
coefficient
parameter on
permanently
mode. UEs report LOFD-001022
E-UTRAN.
patterns:
used
indicates fortothe pattern
aUEs.stronger 1 LBFD-00201801
applied
RANK, CQI, and NO NO No LOFD-001023
A
and larger
pattern
measurement
smoothing value 2.
effect of
In LBFD-00201802
TM4:
PMI Transmission
values to gapthe
this
and parameter
pattern
quantity
mode
eNodeB. 4 1,
higher
Indicates is the
inwhether
inter-
indicates
width
RAT
the is 6 ams
measurements
resistance
measurement stronger
to and
fast LBFD-00201801
permanently
OC_ADAPTIVE: NO NO No
smoothing
the
of repetition
GERAN.
fading,
threshold but effect
it
needs period
may to LBFD-00201802
applied
UEs switchto UEs.
and
is
A 40 higher
great
weaken
be set.ms. value
theIn pattern
of
tracing this
TM6:
between Transmission
the LOFD-001020
resistance
2, the parameter
parameter
capability
If this gap to open-
width fastis
indicates
towards is 6 NO NO No LBFD-00201801
mode
loop and6 isclosed- LOFD-001023
LBFD-00201802
fading,
ms
a
set and
strong
varying but
the
toadaptive
CFG, it
smoothing
signals. may
the For
permanently
loop LOFD-001023
weaken
repetition
effect
details,and
SMeasure the
see periodtracing
high is
a 3GPP
applied
MIMO to
modes UEs. NO NO No LOFD-001019
capability
80 ms. Fortowards
anti-fast-fading
TS 36.331.
parameter details,to
needs
automatically.
varying LOFD-001020
seeset. 3GPP
capability,
be Ifsignals.
TS a low
but
this For
details,
36.331.
signal change see 3GPP LOFD-001021
parameter is set to
TS
tracing36.331.capability. LOFD-001022
NOT_CFG, the
For
SMeasuredetails, see
3GPP TS 36.331.
parameter does not
need to be set.
during
Indicates
Indicates which the
whether
evaluations
measurement
mobility-based of the cell
UE medium
threshold.
Indicates
handover When
the and
cycle
high
during mobility
the quality
measurement which of states
the
in
serving
parameters is
evaluations cell of theto
need
RRC_CONNECTE LBFD-00201801
higher
UE
be set. normal thanmobility the
D mode are LBFD-00201802
threshold,
state
If this in
parameter the UEis
performed. Ittheisto one LOFD-001019
does tonot
RRC_CONNECTE
set CFG, need
of the key NO NO No LOFD-001020
measure
D modesupports
system
Indicates the
arethe intra-
parameters LOFD-001021
frequency,
performed.
setting of mobility-
handover Itinis one
inter-
number
deciding on a UE's LOFD-001022
LOFD-001007
frequency,
of the
threshold key
based handover and
used in NO NO No
mobility state. If this LOFD-001022
LOFD-001008
inter-RAT
parameters
measurement
the UE medium
Indicates the in
parameter
neighboring
deciding
parameters.
mobility on
state isacells.
Ifset
UE's
this to
handover number LOFD-001007
a small
Thus,
mobility
parameter
evaluation. the value,power
state. isIf set Ifinthis
the to NO NO No
threshold used LOFD-001008
switchings
consumption
parameter
NOT_CFG,
number of is among
the is to
set
the UE high mobility
mobility
reduced.
a small
system
handovers statesnot
value,
does may LOFD-001007
state evaluation. If NO NO No
be frequent
switchings
support setting and
among the LOFD-001008
performed
the numberduring of of a
decision
mobility
mobility-based
period precision
ofstates
time may
handovers
Indicates the
may
be
handover
specified be
frequent relatively
by and
the the NO NO No LOFD-001007
performed
scaling factor during for a
low.
decision If this
measurement
TcrMaxConnMode precision
period
the of time
time-to-trigger
parameter
may be relatively
parameters.
parameter
Indicates theis set to
exceeds
specified
defined forby the
medium- LOFD-001007
a large
Indicates
low.
the
scaling If
value value,
this the
of this
factor for a NO NO No
TcrMaxConnMode
mobility UEs. For LOFD-001008
switchings
filtering
parameter
parameter,
the time-to-trigger among
coefficient
is
the setUE to
parameter
UE in medium exceeds
mobility
for
a
is RSCP
large
considered
defined states
value,
for high- toarebe
the valuethe
mobility,
Indicates of this
the time-to-
upper- NO NO No LOFD-001007
less
in frequent
measurements
switchings
medium
mobility UEs. among and
mobilityFor on
parameter,
trigger
layer used
filtering the in UEa
the
UTRAN.
mobility
state
UE decision
inandhigh states
its
mobility, are
is
eventconsidered
evaluation to be
coefficient
precision
A
less
the largerfrequent
handover-related isfor and
value
time-to-trigger of is
Ec/No
NO NO No
LOFD-001007
in high
multiplied
measurements mobility
by thison LOFD-001008
relatively
this
the parameter high.
statedecision
parameters
used
scaling
UTRAN. in factor,
and event itsareto
indicates
precision
adjusted.
evaluation aisisstronger
handover-related
facilitate
A larger value triggering of LOFD-001019
smoothing
Indicates
relatively
multiplied theeffect
high.
byare this NO NO No
parameters
of
this the
Indicates handover.
parameter LOFD-001022
and
number
scaling
Indicateshigher ofthe
factor, to
adjusted.
indicates
maximum
resistance
periodical athe stronger
number
to fast
facilitate
measurement triggering LOFD-001019
smoothing
of cells but
fading,
measurement to be effect
it may for NO NO No
of the
quantity handover.
required LOFD-001022
LOFD-001020
and
included
weaken
reports higher to inbe
the thetracing
sent
the inter-RAT
resistance to fast LOFD-001023
measurement
capability
after an towards
inter-RAT LOFD-001020
handover
fading,
Indicates but toit may
the NO NO No LOFD-001021
report
varying
handover after
signals. an inter-
event For
is LOFD-001023
UTRAN.
weaken
interval atthe whichtracing LOFD-001019
RAT
details,
triggered.handover
see It 3GPP
is used LOFD-001021
The RSCPtowards
capability
periodical values LOFD-001022
event
TS
to prevent is triggered.
36.331. thestable, NO NO No LOFD-001019
are
varying relatively
measurement
For details,
impact
and Ec/No of see For
signals. LOFD-001022
details,
reports
3GPP TS
measurement see
are 3GPP
sent
36.331. LOFD-001020
LOFD-001043
fluctuates
TS
after 36.331.
the muchfor
event NO NO No LOFD-001023
report
with the loss and
network LOFD-001046
Indicates
the handover the to LOFD-001046
internal
load. Forat processing
details,
interval
GERAN which
failure
see 3GPP onisthe TS NO NO No
LOFD-001019
periodical
triggered. LOFD-001022
handover.
23.003. For
measurement
For
Indicatesdetails, the see
details,
Indicates
Due toTS see
the the 3GPP LOFD-001019
reports
3GPP
quantity are
used sent
36.331. to
TS 36.331.
measurement
specification
Indicates the in for NO NO No LOFD-001022
after
evaluate the eventthe
quantity required LOFD-001043
3GPP
interval
the TS
handover
triggering
at 36.331
which
condition to for of
the inter-RAT
Release is9,triggered.
periodical
UTRAN the
for the inter-RAT NO NO No LOFD-001021
handover
value details,toseeevent
measurement
For
measurement
CDMA2000
UTRAN_BOTH 1xRTT. now
reports
3GPP
Indicates TS are sent
36.331.
the
A1
For or
Indicates
has the A2.
details, sameThe
the see effect
after
measurementthe event for NO NO No LOFD-001021
values
3GPP
interval
as the are
TS at
value RSRP,
36.331.
which
the
quantityhandover required to for
RSRQ
periodic
UTRAN_RSCP and reports BOTH. are
and
CDMA2000
the inter-RAT 1xRTT
The
sent measured
to
reserved the eNodeB
for later NO NO No LOFD-001021
is triggered.
handover to are
RSRP
after
eNodeB the values
triggering
versions.
For
CDMA2000
Indicatesdetails, the seeHRPD.
stable,
Indicates
condition varying
the
of thelittle
3GPP
For
number TS
details, of 36.331.
see NO NO No LOFD-001021
with the
quantity
maximum
event for load,
used number and
to
3GPP
periodical
therefore TSinter-RAT
36.331.
there
LOFD-001020
evaluate
of cells tothe
handover be is
to LOFD-001023
measurement
little
triggering
included signal incondition
the
CDMA2000 HRPD NO NO No LOFD-001021
reports
fluctuation.
for the
measurement to be
intra- The sent
is met. LOFD-001019
after
measured
frequency
report an event
after RSRQ
handover
an for
For details, see LOFD-001022
LBFD-00201801
the
values
event.
event intra- vary
The or inter-
with
quantity the
3GPP for TS the
36.331. intra- NO NO No
LBFD-00201802
frequency
load
can and
be RSRP
or inter-frequency arehandover
likely
or
within
to
RSRQ.reflect
handover thethe E-UTRAN
within signal the LBFD-00201801
is triggered.
quality
The
E-UTRAN of the
measured is cell in NO NO No LBFD-00201802
It is used
real
RSRP time.
triggered. values to
By
For prevent
are LOFD-001032
the
stable,
details,impact
default,varying of
the 3GPP
see little
measurement NO NO No LBFD-00201801
reporting
with
TS 36.331.the load, quantity and
report
for the loss
therefore inter-RAT and is
there
internal
handover
little signal processing
event is
failure
BOTH,on
fluctuation. that the is, both
The
handover.
RSRP andFor
measured RSRQ.
RSRQ
details,
For details,
values see see
vary 3GPP
with the
TS
3GPP
load 36.331.
and TSare 36.331. likely
to reflect the signal
included
RSRQ, orinboth. the
measurement
The measured
report
RSRP for values the inter- are
frequency
stable, varying handover little
event.
with theThe load, quantity
and
can
thereforebe RSRP, there is
Indicates
RSRQ,
little signal orthe both.
interval
Indicates
The
Indicates measured
fluctuation. atthe which
the The time-
periodical
quantity
RSRP
to-trigger used
values for into
are
event NO NO No LBFD-00201801
measured RSRQ
measurement
evaluate
stable,
B1
valuesthatvary isthe
varying used with little
inthe
Indicates
Indicates
reports
triggering are the
the sent
conditiontime- LBFD-00201801
with
CS
load the
fallback
and load,
are and
tolikely NO NO No
triggering
to-trigger quantity
for
after
for
UTRAN.
to an intra-
inter-frequency
therefore
reflect
Indicates
for frequency- the event
there
When
the signal is
CS LOFD-001032
B1
littlethat
frequency
measurement
Indicates
fallback
quality
interval signal is
of tothe
at used
handover
theUTRAN
which time-
cell in in
event
priority-based
CS
event
A1 fallback
or
to-trigger is
A2. triggered.
for toevent inter- LBFD-00201802
fluctuation.
is
realapplicable,
time. Even
periodical The this NO NO No
frequency
GERAN. LOFD-001032
For
The
B1,
measured
parameter
when
measurement
measurement thisWhen
details,
quantity
which issee
is
RSRQ setCS
can
used
event
be
forin
fallback
3GPP
RSRP,
CS
values
UEs
parameter
reports and TS
fallback to
RSRQ,
vary
are usedGERAN
36.331.
is to
with
sentset orthe
in to LBFD-00201802
A1.
is The
applicable,
both.
CDMA2000. The quantity
measured this
When NO NO No
load
the
BOTH,
after and
evaluation
an the are
inter- likely
eNodeB of LOFD-001032
can
parameter
Indicates
RSRP
CS be
fallback either
values theis to RSRP
set
arefor
Ec/No
to reflect
whether
triggers
frequency a the
tohandover signal
trigger
handover
or
UEs RSRQ.
threshold
stable,
CDMA2000 and varying The
used
for isevent in
little
quality
event
based B1.of
ison the
When
the
triggered. cell in NO NO No LBFD-00201802
measured
the
B1, evaluation
which RSRP
is used of
with
detecting
setting
For theofload,
applicable,
real time.
details, that
the this
see the in
and
values
whether
CS fallback
therefore are totherestable,
trigger
toset
parameter
After
signal an
IntraFreqHoA3Trig
3GPP TS inter-
quality is
36.331. inisat for
varying
Indicates
event
UTRAN.
little
UEs B1.
signal
and little
the
When
When
used with inCS
frequency
least
Quan one
parameter. handover
UTRAN NO NO No LBFD-00201802
the load,
triggering
detecting
fallback and
quantity
that the
fluctuation.
the
event
cell
For meets
Indicates is to
evaluation
details, theUTRAN
The
triggered,
the
see RSCP of
therefore
for
signal
is frequency-
quality
applicable,
measured
whether to there
RSRQ in
this
trigger isat
the default
entering
threshold
3GPP TS 36.331.forreporting
condition, event
little
priority-
least
parameter
values signal
one and
vary GERAN
is load-
set
with for NO NO No LBFD-00201802
event
quantity
the
B1, UE
whichB1. isWhen
does BOTH,
is not the
used in
fluctuation.
based
cell
UEs
load meets
Indicates
detecting and inter- used
are
the
that The
the likely
localin
the
thatfallback
send
CS is,a both RSRP
to
measured
frequency
entering
the
to
ID ofevaluation
reflect
signal thequality the RSRQ
handover
condition,
cell. signal
It CS
in at
and RSRQ.
measurement
UTRAN. When For YES YES No LBFD-001001
values
event
the
about
qualityUE
uniquely
least A4.vary
does
whether
one of the with
identifies not
cell to the
ina
details,
report totothe
fallback see 3GPP
UTRAN
load
send
trigger
real
cell
CDMA2000 and
a
time.
within event are
For
a BS. likely
B1.
cell
TSapplicable,
eNodeB
is 36.331. this
to reflect
measurement
This
details, parameter
see the signal
meets
immediately.
parameter
quality
the
of theis3GPP
entering
set
cell for
in
NO NO No LOFD-001033
report
indicates
TS 36.331.
condition,
Instead,
UEs and to the
thethe
theUE
used Ec/No
UE in
real
eNodeB
does time.
requirementnot For
send foraonly the
sends
the a report
evaluation
details,
immediately.
UTRAN see
cells 3GPP NO NO No LOFD-001034
measurement
when the
about whether signaltobeto
TS 36.331.
Instead,
included
report the
in the UE
qualityto
trigger event the
continuously B1.
sends
measurement
eNodeB
Indicates
meets
This a report
thethe
parameter enteringRSSI only
Indicates
when
report. the
A UEthe
signal sends NO NO No LOFD-001035
immediately.
threshold
condition the
indicates for event
during RSCP the
Indicates
emergency
quality
a
B1 thatcontinuously
measurement
Instead,
time-to-trigger. isthe the
usedcall
UE pilot in
requirement forThis the
strength
barring
meets
report
sends
CS the
related
fallback
parameter a threshold
status entering
report toto
helps to ofonly
UTRAN cells be NO NO No LOFD-001033
related
access
condition
event
when
GERAN.
decrease to
class
B1 in
the event
during
Ato
signal
theUEthe B1,
10, the
included the
which
indicating
eNodeB
quality is
time-to-trigger.
numberacontinuously
sends used
of whether
when in This
the CS
measurement
fallback
UEs ofin toatentering
parameter
Ec/No
meets
measurement
occasionally
report. Aaccess
the UE helps
least
sends class NO NO No LOFD-001033
CDMA2000.
10 can
decrease
one
condition
report
triggeredUTRAN initiate
related the
during A
cell
event the to UE
a measurement
sends
emergency
number
exceeds a
time-to-trigger. of to calls.
this
event
report B1
reports,related the the toThis NO NO No LOFD-001034
measurement
If this
occasionally
threshold parameter and theis
parameter
eNodeB
average
event B1when number
to theother
helps of
report
set
RSSI to
triggered
triggering
reduce
handovers, related
inthe at event
number
least
andtheto one
the
eNodeB when
event
BOOLEAN_TRUE,
reports,
conditions
of
GERAN B1the
occasionally
number toare
cell themet.
RSCP inof atwrong
least NO NO No LOFD-001035
eNodeB
UEs
average
For
exceeds a
triggered
handovers,ofcell when
access
number
with
event
this and theof
large
one
IndicatesUTRAN the cell
local
pilot
classes
handovers,
signal
reports,
threshold
thus strength 0
fading
the to
and and9 in or at
otherthe
ID
least
thoseof helps
exceeds
number the
one
without
of
this prevent
cell.
wrong ItIMSIs
variance,
average
triggering
unnecessary
threshold set
number
and this other ofa YES YES No LBFD-001001
uniquely
CDMA2000
cannot
handovers, identifies
initiate cell
parameter
handovers,
conditions
Indicates
handovers.
triggering toand
and
are
whether
For amet. the
cell
exceeds within aprevent
BS. If
emergency
thus
large
number
For
to
details, helps
value
details,
configure
conditions ofthis
see calls.
to
wrong
see
are themet.
3GPP LBFD-001001
threshold
this parameter
unnecessary
prevent
handovers, and and other
is NO NO No
3GPP
access
TS 36.331.
For TS
details, barring36.331.
see LBFD-002009
triggering
set to
handovers.
unnecessary
hence
information.
Indicates helps the For
3GPP TS 36.331.
conditions
BOOLEAN_FALSE,
details,
handovers. seeare
prevent probability
access 3GPP
For met.
a
Indicates whether
the NO NO No LBFD-002028
For
UEs
TS
cell details,
of
36.331.
with
unnecessary
factor foraccess
small see
mobile-
to configure
mobile-originated
3GPP
classes
signal TS 0 to
fading the
36.331.9 and
handovers.
originated
access barring For
calls. A LBFD-001001
call
those barring
variance, without set statusIMSIs
this
details,
mobile-originated
Indicates see the 3GPP NO NO No
information
of
can access
parameterinitiate for
class
to a 11, LBFD-002009
TS
call 36.331.
is granted
mobile-originated
mobile-originated
indicating
emergency
small value whether
calls.
to
access
call
calls.
UEs barring if thestatus
ofinaccess LBFD-001001
A UE
ensure
random
of access
Indicates
access
that
number
class
the theclass 12,
NO NO No
LBFD-002009
11 can
classes
handover initiate
11is to 15
generated
indicating
average
mobile-originated by
whether
access the
cannot
performed
UE
UEs isofless initiate
access in time.
than this
class LBFD-001001
barring
calls. duration for NO NO No
emergency
For
access
12 details,
can probability
initiate calls
see LBFD-002009
mobile-originated
If this parameter is
only
3GPP
factor; whenTS its
36.331.
otherwise,
mobile-originated
calls.
set to LBFD-001001
access
the
calls. access class and
request NO NO No
BOOLEAN_TRUE,
access class 10 are LBFD-002009
is
If
UEs rejected.
this of parameter
access classis
both
set to barred. If its LBFD-001001
11 cannot
access class initiate
or NO NO No
BOOLEAN_TRUE,
mobile-originated LBFD-002009
access
UEs class
ofIf access 10class is
calls.
not barred, this
12 cannot initiate
parameter iscalls
set to
emergency
mobile-originated
BOOLEAN_FALSE,
initiated by the UE
calls.
UEs ofIf access
this class
are granted
parameter isaccess.
set to
11 can initiate
BOOLEAN_FALSE,
mobile-originated
UEs
calls.of access class
Indicates
of access the class 13,
mobile-originated
indicating whether
call
UEs barring
of access status class
Indicates
of access the
class 14,
13 can initiate
mobile-originated
indicating
mobile-originated whether
call
UEs barring
of access status class
calls.
of access class 15,
14
If can initiate
this parameter is
indicating
mobile-originated whether
set
UEs to of access class LBFD-001001
calls. NO NO No
BOOLEAN_TRUE,
15this
canparameter
initiate is LBFD-002009
If
UEs of access class
mobile-originated
set to LBFD-001001
13 cannot initiate
calls. NO NO No
BOOLEAN_TRUE,
mobile-originated LBFD-002009
If
UEsthisofparameter is
calls.
set to If access
this class
LBFD-001001
14 cannotthe
Indicates
parameter initiate
is set to NO NO No
BOOLEAN_TRUE,
Indicates
mobile-originated
access whether
probability LBFD-002009
BOOLEAN_FALSE,
Indicates
UEs of access the class
to configure
calls. the
factor
UEs
signaling
15 ofIffor
cannot
this
accesssignaling.
barring
initiate class LBFD-001001
access
parameter
Signaling barring is
from seta to
UE NO NO No
13 can
status initiate
of
mobile-originated access LBFD-002009
information
BOOLEAN_FALSE,
is granted for
Indicates
mobile-originated
class
calls. 11,this
If indicatingif
access
the
signaling.
UEs
the of
random
signaling accessbarringnumberclass LBFD-001001
calls.
whether
parameter the isUEs set of
to NO NO No
14 can
generated
status
access class initiate
of by
access the
11 can LBFD-002009
BOOLEAN_FALSE,
Indicates
mobile-originated
UE
class is 12, the
lessindicatingthan this
initiate
UEs
average
signalingof signaling
access
access
barring class LBFD-001001
calls.
access
whether
access. probability
the UEs of NO NO No
15 can
barring
status
factor;
access initiate
duration
of access
otherwise,
class 12 for LBFD-002009
If this 13,
Indicates
Indicates parameter
mobile-originated
signaling.
class the
whether
indicating is
the
can
set access
initiate
to
signaling request
barring LBFD-001001
the
calls.
is cell
whether
rejected.
signaling is the reserved
access. UEs of NO NO No
BOOLEAN_TRUE,
status
for future
access ofclass
access
extension. LBFD-002009
If
UEsthis
Indicates
class parameter
ofcell
14, access the 13class
indicating is
If
can
setthe initiate
to is LBFD-001001
signaling
11 cannotUEs
whether barring
initiate
of a
reserved,
signaling whether
access. NO NO No
BOOLEAN_TRUE,
status
signaling ofclass
access
access. LBFD-002009
access
UE
If
UEs can
this
class
accessclass
parameter
of15, accessindicating
14 isIf
the
this
can
cell
set parameter
initiate
depends
to UEs on isthe LBFD-001001
12
set cannot
whether
to class
signaling initiate
access. of NO NO No
access
BOOLEAN_TRUE,
signaling access. of the LBFD-002009
access
BOOLEAN_FALSE,
If this class
parameter 15 isIf
UE
UEs
this and its serving
of access
parameter class
is
can
UEs
set initiate
to of access class LBFD-001001
PLMN.
13
set cannot Details
to initiate initiate are NO NO No
signaling
11 can
BOOLEAN_TRUE, access. LBFD-002009
described
signaling as
access.
BOOLEAN_FALSE,
If thisofparameter
signaling
UEs accessaccess. isIf
class
follows:
this
UEs parameter (1) A UE is of
set
14 toof access
cannot initiate class LBFD-001001
access
set class
to initiate 11 or NO NO No
12 can
BOOLEAN_TRUE,
signaling
Indicates access.
whether If LBFD-002009
15 treats the
BOOLEAN_FALSE,
Indicates
signaling the
access. cell
local as
UEs
this
the of access
parameter
cell is barred. class
is If
a
UEs
ID candidate
of of
the access
cell. when
Itclass
15
set
the cannot
to
cell initiate
isidentifies
barred, YES YES No LBFD-001001
the
13 UE initiate
can
uniquely is served by
Indicates
signaling
BOOLEAN_FALSE,
the UE cannotaccess. Ifa
whether
its
the HPLMN
signaling
cell within
cell can a or
access. BS.
initiate LBFD-001001
this
UEs parameter
ofon access is
camp
EHPLMN;
the the
intra-frequency (2) Aclass UE NO NO No LBFD-002009
set
14 to
can
serving initiate
cell. During
of access
reselection 11
Indicates
cell class
whether LBFD-00201803
BOOLEAN_FALSE,
signaling
cell
or 15
the
when
UEs celltreats
ofthe is access.
reselection,
access
the
reserved
cell the
cell
isclass LBFD-001001
serving
as aoperator
for
barred. cell
barred cell is
use.not NO NO No LBFD-002009
15 can initiate
selected
when
If this
NOT_ALLOWED
Indicates it isas
parameter nota PLMN
the is LBFD-00201803
signaling
candidate access.
cell. LBFD-001001
served
set
means to by
broadcast thatits modethe UE of
HPLMN
CELL_RESERVED or setting NO NO No LBFD-002009
cannot
the cell.initiate
The the
EHPLMN;
_FOR_OP, (3)
theAcell UE LBFD-00201803
intra-frequency
of this parameter cell LBFD-001001
of
is access
reserved
reselection,
determines in which classes
for
and NO NO No LBFD-002009
0-9 and 12-14
operator
ALLOWED
sequence use.themeansUEs LBFD-00201803
Indicates the period
treats
of
thatAC11
PLMNs the the orcell
UE
are AC15
can as ain LBFD-001001
of changing the
barred
their
initiate
broadcastHPLMNcell.
the overthis
In
intra-or the NO NO No LBFD-002009
PLMN broadcast
version,
EHPLMN
frequency
Indicates
air interface. the can
celllocal
the LBFD-00201803
sequence.
Indicates the
parameter
consider
of the this
reselection.
ID
Indicates cell.
thestillcell
It ofas
ID
percentage
supports
a candidate setting of
cellRBsfora YES YES No LBFD-001001
uniquely
the tracking identifies
area
occupied
synchronization
cell selection by the or
that within
the
Indicates cell a belongs
the BS. LBFD-001001
operator
between
reselection. on
theof the
M2000
UEs
to. Operators
percentage
PUSCH when of
RBs
RANaof YES YES No LBFD-002009
and
AC11
cell the or
use is
occupied eNodeB,
AC15
the by same
the LBFD-00201803
sharing
but is notheir
outside enabled
longer LBFD-001001
tracking
operator
at theinternally.area
eNodeB. on theID for
used
HPLMN/EHPLMN
the
PDSCH cell. when RAN NO NO No LBFD-002009
When
Avoid
and UEs the
using data this
sharing
volume isofenabled
is
AC0- LBFD-00201803
LBFD-001001
parameter
9/AC12-14
at the eNodeB. as it will
consider
sufficiently
be
this removed
cell as large,
a from
barred NO NO No LBFD-002009
When
the the data of
percentage LBFD-00201803
the
cell
volumelater
during isversions.
cell LBFD-001001
RBs
selectionoccupied or by
sufficiently
each operator large, will NO NO No LBFD-002009
reselection.
the percentage of LBFD-00201803
Indicates
reach the the
preset local
If
RBsthisoccupied
parameter by is
ID of the
value. cell. It
Modifications
set
each to YES YES No LBFD-001001
on thisoperator
uniquely
CELL_NOT_RESE
identifies
parameter will a
reach
cell
affect the
within
operators' preset
a BS.
RVED_FOR_OP,
value. Modifications
percentages
the cell is notof
on
RBs. this parameter
reserved
affect operators' for
operator
percentages of use. All
UEs
RBs. can consider
this cell as a
candidate cell for
cycle.
parameter
frequently Thistransitingmust be
parameter
set onhigh
from the or is oneofof
basis
Indicates
the
medium key
slowparameters the
fading
mobility to
threshold
in deciding
characteristic
normal for
mobility. the aofUE the
to
area
This enter
mobility. covered
parameterthe
Themedium lower
byisthe
mobility
the
cell.parameter
one That
of the state.
is,key theis,
Based
the
greater higher
parameters on thethe transiting
slow
in
number
sensitivity
Indicates ofthe itcell
the isUE foris, LBFD-001001
fading variance
deciding
reselections,
the UE.
threshold However,
for athis UE NO NO No LBFD-002009
largerThe
mobility.
Indicates the value
whether
parameter
the
to accuracy
enter the ishighone
of theof LBFD-00201803
of the
greater
to set the hysteresis
the LBFD-001001
the
UE
mobility
should keybe.
mobility
parameter parameters
state. A
is, larger
the
parameters related NO NO No LBFD-002009
in
Based
valuedetermining
deciding
higher onthe isthe
ofaccuracy lower. the it is
to speed-dependent
Indicates the LBFD-00201803
mobility
The
number
hysteresis
for thelower state
of
deciding the
cell
results of the
of in LBFD-001001
cell reselection.
measurement
UE.
transitingDuring
reselections,
a bigger
UE transiting
Indicates boundary
the the
sensitivitythis
from UE NO NO No LBFD-002009
triggering
mobility
is, theorserving
parameter
of
high the medium threshold
evaluation,
higher is one cellof LBFD-00201803
scaling factor
for the
ifapplied
the
accuracy reselection
number of for LBFD-001001
the
andkey
mobility a higher toitQhyst
parameters
to is for
normal
of the inter-
reselections NO NO No LBFD-002009
deciding
in determining
probability
mobility.
medium-mobility the ofis
However, UEcellthe
frequency/inter-RAT
above
Indicates
mobility.
mobility or equal
the
state ofto the LBFD-00201803
reselection
the
UEs. transiting
Indicates This to
factor
whether LBFD-001001
cell.
the
scaling
When
UE.
neighboring
sensitivityThe
value the
During step
factorof this
the
is the is
cells.
lower. UE2.
indicates
to configure the NO NO No LBFD-002009
When
parameter
applied
mobility
DB0_Q_HYST
When the
the to and
Qhyst
is set to
evaluation,
transiting for
additional
measurement LBFD-00201803
reselection
below
high-mobility
S30_T_EVALULATI
ifsensitivity
the number
means than
0dB is priority
the
of UEs.
of cell
higher, LBFD-001001
hysteresis
triggering applied
threshold
is
value
This
ON, higher of UE
factor
the
reselections
hysteresis.
the deciding than isthe
indicates
mobility NO NO No LBFD-002009
to
of Qhyst.
the inter-
serving
NCellChangeHigh,
the
deciding
above additional
DB1_Q_HYST
accuracy or frequency
cycle
equal
is lower. isto LBFD-00201803
For example,
frequency/inter-RAT the
of
the
30s.
the
meanstheUE
hysteresis inter-
When
value enters
1dB of of applied
thethis the LBFD-001001
When
value
cell the
reselection.
frequency/inter-
medium
to Qhyst.
parameter, mobilitythe NO NO No LBFD-002009
hysteresis.
parameter
DB_6_Q_HYST_SF
When theUE is setUE to
RAT,
state.
For the
example,
Indicates
S60_T_EVALULATI
enters thethe high always
the LBFD-00201803
S30_T_HYST_NOR
_MEDIUM
parameter indicates
ismobility
setin LBFD-001001
triggers
A
ON,
MAL,
-6 smaller
value
threshold
dBthe
mobility the the
UE value
used
state.
additional estimating ofto
CFG,
measurement. the NO NO No LBFD-002009
this
deciding
A
time parameter
DB_6_Q_HYST_SF
the evaluation
smaller
hysteresis for the cycle
value UEfor
applied isto
of
measurement
If the reselection LBFD-00201803
results
_HIGH
reselection
60s,
this
Indicates
transit
to and in
parameter
Qhyst to for a
indicates
so
the
normal higher
toon. a -6 LBFD-001001
triggering
priority
probability
dB additional
neighboring ofisathethreshold
of a
cellinter-
UE on
results
reselection
mobility
medium-mobility in 30s.higher
priority NO NO No LBFD-002009
of the inter-
frequency is
entering
hysteresis
a
probability
of
When
UEs, theand thethe
lower-priority
cells ofless
applied a UE E- LBFD-00201803
frequency/inter-RAT
than or equal to
medium
to
UTRANQhyst
entering
assigned
parameter
DB_4_Q_HYST_SF mobility
orfor
thewith high-
inter-
is high
set thetheto LBFD-001001
cell
serving
state.
mobility
RAT reselection
A frequency
larger
UEs,
frequency. is
value
and Aas NO NO No LBFD-002009
same
S60_T_HYST_NOR
_MEDIUM state.
frequency indicates A
configured.
or
of
UE when
this
DB_4_Q_HYST_SF
can the
parameter
reselect When to LBFD-00201803
larger
the
MAL,
-4 dB value
serving
the
additional of this
one.
estimating 0 LBFD-001001
the
_HIGH
such parameter
reselection
leads ato a priority
lower
indicates
neighboring is set
-4
parameter
indicates
time
hysteresis.for the the leads
UE lowestto to NO NO No LBFD-002009
to
of NOT_CFG,
the
probability.
dB
cell inter-RAT
additional
Indicatesif no intra-
whether the is
a lower
priority.
transit to probability.
The normal value LBFD-00201803
measurement
less than
hysteresis.
frequency
to
of configure
this
mobility
Indicates
triggering isthe
parameter 60s,
whether theand
threshold
LBFD-001001
serving
neighboring
maximum
must
so on.be frequency,
TX
determined cell power NO NO No LBFD-002009
Indicates
to
of configure
the thethe
the
meets
of the
togetherUEinter-
the
UE does in
with not
the the LBFD-00201803
minimum
measurement
frequency/inter-RAT required
trigger
reselection
intra-frequency
priorities theofinter- criteria
other LBFD-001001
RX level
triggering
cell reselection for the is
threshold
frequency/inter-RAT
and no
neighboring
frequencies higher- cell.
during NO NO No LBFD-002009
intra-frequency
of
not the intra-
configured.
measurement
priority
When
the network
Indicates neighboring
the the when LBFD-00201803
neighboring
frequency cell E- LBFD-001001
the
cell signal
parametermeets
planning.cell.
maximum quality
the
is
Cells
TX powerset oftoof
UTRAN
reselection. NO NO No LBFD-002009
the serving
conditions
CFG,
Indicates
different
of the UE the forcell
maximum
the
RATsin the cell is
When
higher the
than this LBFD-00201803
reselection.
TX
cannot
cell. power
measurement
reselection
parameter have
If this ofis the
set UE
duration to LBFD-001001
parameter,
is
same configured.
triggering
of the
parameter E-UTRAN.
reselection and
threshold
is notWhen NO NO No LBFD-002009
CFG,
triggers the the inter-
the
for
When parameter
reselection
priority.
included
measurement the insignal
the is
to set LBFD-00201803
frequency/inter-RAT
to NOT_CFG,
intra-frequency
quality
SIB3, the UE of the the
new
uses LBFD-001001
triggering
measurement threshold when
maximum
cells.
cell
thethe is The
better
maximum TXthan
step power
TXis 2 NO NO No LBFD-002009
of
the signalintra- quality
of
dB.
the the
power. UE
serving
frequency is
cell not
cell allof LBFD-00201803
the serving cell isUE LBFD-001001
configured.
The
the UE starts
time
reselection
Indicates andthe isthe intra-
lower than this NO NO No LBFD-002009
frequency
stays
configured.
measurement in the When current
Indicates
parameter. whether LBFD-00201803
measurements
serving
the parameter
bandwidth cell forfor isonly set LBFD-001001
to
when
more set than the signal
the 1s, the
to NOT_CFG,
neighboring cells.the NO NO No LBFD-002009
measurement
quality
UE in the cell
isparameter
initiating
measurement
This is LBFD-00201803
bandwidth.
serving
reselection cell isislower LBFD-001001
triggering
optional. itrequest
Ifthreshold not
than
to the orintra-
new equal cell. toThe the NO NO No LBFD-002009
of the
set, the default
value
smaller of this
the LBFD-00201803
frequency
value
Indicates of this cell
the LBFD-001001
parameter.
parameter
reselection
parameter
scaling factor is,
isisused,the
not
Indicates whether NO NO No LBFD-002009
easier
configured.
which
applied the
is tothe cell DL
to set the the speed- LBFD-00201803
reselection
Indicates
bandwidth
TReselEutra offrom the the
for LBFD-001001
dependent
serving
scaling cell
factor scaling
is
serving
medium-mobility cell. NO NO No LBFD-002009
parameters
triggered,
applied and
to actual forthe cell
UEs. The cell LBFD-00201803
reselection
more
TReselEutran possibly within that
for E- LBFD-001001
reselection
UTRAN. time for
the pingpong UEs.
high-mobility NO NO No LBFD-002009
medium-mobility
reselection
The occurs. LBFD-00201803
UEs actual within cell E- LBFD-001001
The bigger
reselection
UTRAN is equal the
time for to NO NO No LBFD-002009
parameter
high-mobility
TReselEutra is, UEs the
LBFD-00201803
more
within
multiplied difficult
E-UTRAN by the is
cell
equal reselection
to
TReselEutranSfMe from
the serving
TReselEutran
dium. cell is
triggered, by
multiplied and the
less possibly that
TReselEutranSfHig
the pingpong
h.
reselection occurs.
the neighboring
cells are sharing
Indicates whether
theintra-frequency
all same MBSFN
subframe cells
neighboring
01:
are Indicates
configurednowith
MBSFN
at least two subframes
are present
antenna ports. in all Set LBFD-001001
neighbour
this parameter cellsto
NO NO No LBFD-002009
10: Indicates
TRUE if all intra- the
LBFD-00201803
MBSFN
frequency
Indicates subframe
the LBFD-001001
allocations
neighboringofcells
network all NO NO No LBFD-002009
neighbour
are configured
synchronization
Indicates the local cells are
with LBFD-00201803
identical
at least
status. Iftwo
ID of the cell. It to
this or
subsets YES YES No LBFD-001001
uniquelyof
Indicates
antenna
parameter that
whether
ports.
is
identifies setSetintoa
the
to serving
thisset the whether
parameter
BOOLEAN_TRUE,
cell within
Indicates acellBS.to on
LBFD-001001
this
FALSE
the
to frequency
CDMA2000
E-UTRAN
set the if onesearchsystem
intra-
and NO NO No LBFD-002009
11:
the The
time
window neighboring
information.
frequency
CDMA2000 size. If this LBFD-00201803
cells
For of
arethe is
details,
neighboring
RAN
parameter TDD
seecell
set is to LBFD-001001
serving
3GPP
configured TS cell
CFG, the cell is only
synchronized have
36.331.
with NO NO No LBFD-002009
different
one
without antenna
configured uplink
drifts. with If and
port. this
theof LBFD-00201803
Indicates
Indicates
downlink the
whether
allocation size LBFD-001001
parameter
search
the CDMA2000 window. is set Ifto
Indicates
to
For set the whether
details, seeis set NO NO No LBFD-002009
BOOLEAN_FALSE,
the
searchparameterwindow, and
to set the
parameters
3GPP TS HRPD related
36.331. LBFD-00201803
the
to E-UTRAN
NOT_CFG, and
can bereselection
Indicates
parameters.
to cell used whetherIftothe
thisto LBFD-001001
the
cell
assistCDMA2000
is not
in searching
pre-registration NO NO No LBFD-002009
parameter
CDMA2000 isHRPD.setwith to
RAN
configuredare not with
for
CFG,
If the
CDMA2000
the theneighboring
parameter cell HRPD is the is LBFD-00201803
synchronized.
search
pilots.
is allowed Forwindow.details,
when For For
the LBFD-001001
Indicates
configured
set to CFG, thewith
the the cell
details,
details,
see
UE 3GPP
does see
see notTS 3GPP
3GPP
have a NO NO No LBFD-002009
duration
HRPD
is configured used
parameters. withcell
in
TS
TS
valid36.331.
36.331.
36.331. pre- LBFD-00201803
reselection
If the
the parameter
parameters to is LBFD-001001
Indicates
registration.
CDMA2000 theHRPD.
IfID theof
set to NOT_CFG,
related to cell NO NO No LBFD-002009
the pre-registration
Indicates
parameter
The whether
UE isinitiates istoset to
the cell
reselection not LBFD-00201803
CDMA2000
secondary
BOOLEAN_TRUE,
reselection pre-
toHRPD a the LBFD-001001
configured
CDMA2000 with
HRPD.
zone.
the UE This
registration is zone
allowed ID
CDMA2000
HRPD
If parameters.
the parameter
parameter is
HRPD
used isto NO NO No LBFD-002009
0 needs
perform
cell when to
the be pre-
all the set. LBFD-00201803
set
to to
controlNOT_CFG, the
The valueconditions
registration.
following
the cell is
CFG
not Ifre-the LBFD-001001
registration
indicates
parameter
are met: that
(1) isofThesettheto NO NO No LBFD-002009
Indicates
configured whether
with only the
UE and
secondary
BOOLEAN_FALSE,
signal is
quality valid
pre- in the LBFD-00201803
secondary
parameters pre-
related LBFD-001001
when
the UEpre-
registration
Indicates
serving is
cell not zone
secondary
is ID
registration
to cell reselection zone ID
to NO NO No LBFD-002009
registration
0 exists,
allowed
pre-registration
continuously toand is
perform the
lower
1 needs to be
CDMA2000 HRPD. set. LBFD-00201803
allowed.
value
the NOT_CFG For details,
Thepre-registration.
zone
than ID
its
value 0. CFGIt is used
low-priority LBFD-001001
see
For
to 3GPPthat
indicates
details,
control
reselection TS
the see re- NO NO No LBFD-002009
indicates that
36.331.
secondary
3GPP
registration
threshold TS pre-
36.331.
of
during thethe LBFD-00201803
secondary
Indicates whether pre-
registration
Indicates
UE.
time; For
(2) the
details,
The zone signal seeID LBFD-001001
registration
to set the
Indicates secondary zone
speed- ID
0 does
scaling
3GPP
quality TS not
factor
in exist.
36.331.
the NO NO No LBFD-002009
1 exists,
dependent
pre-registration and scalingthe
For
applieddetails,
CDMA2000 to see HRPD LBFD-00201803
value
parameters
zone
Indicates NOT_CFG
ID 1.the Itrelated
is used LBFD-001001
3GPP
indicates
to cell TS
TReselCdmaHrpd
cell is 36.331.
continuously
that
reselection
control
scaling
for factor re- to
high-mobility
the NO NO No LBFD-002009
higher
secondary
CDMA2000
registration thanpre- its
ofHRPD. low-
the LBFD-00201803
applied
UEs. The to actual cell
priority
registration
If this reselection
parameter
UE. For details, see zone ID
is LBFD-001001
TReselCdmaHrpd
reselection time for
threshold
1
setdoes
3GPP to CFG,not during
TS 36.331. exist.
the the NO NO No LBFD-002009
for medium-mobility
high-mobility UEs to
time;
For
system and
details, (3)see
supports The LBFD-00201803
UEs.
CDMA2000 The actual
HRPD cell LBFD-001001
UE
3GPP
the camps
speed-
Indicates TS whether on
36.331. the
reselection
Indicates
is equalserving time
whether
to scaling for NO NO No LBFD-002009
current
dependent
registration cell
medium-mobility
the parameters
TReselCdmaHrpd LBFD-00201803
for more
parameters.
parameters than If
need 1s.
this A LBFD-001001
UEs to CDMA2000
applicable
multiplied
larger value only
by of forto
this
parameter
be
HRPD set for is equal is
CSwith set to to NO NO No LBFD-002009
interworking
TReselCdmaHrpdSf
parameter
NOT_CFG,
fallback
TReselCdmaHrpd
CDMA2000 to indicates
the
1xRTT LBFD-00201803
High.
a higherdoes
system probability not LBFD-001001
CDMA2000
multiplied
need to beby 1xRTT.
set. If
The
of
support value
initiating the cell
speed- NO NO No LBFD-002009
If this parameter
TReselCdmaHrpdSf
this parameter is is
T_RESEL_SF_0DO
reselection
dependent but
scaling acell LBFD-00201803
set to
Medium.
set CFG,
tomeans
CFG, the
T25
higher
parameters. probability athe
For of
cell LBFD-001001
needs
The
needs valueto be
tofactor
be of NO NO No LBFD-002009
scaling
ping-pong
details, seewith 3GPP
configured
T_RESEL_SF_0DO
configured with the
0.25,
reselection.
TS 36.331.
registration A the LBFD-00201803
LBFD-001001
T25
1xRTT means
T_RESEL_SF_0DOparameters. a LBFD-002009
smaller
parameters value forofCS NO NO No
scaling
If
T5 this
means factor
parameter 0.5, and is LBFD-00201803
indicates
Indicates
fallback to athelower
0.25,
set
so to
on. NOT_CFG,
For details, LBFD-001001
LOFD-001035
probability
CDMA2000
CDMA2000 of1xRTT
1xRTT.
T_RESEL_SF_0DO
the
see cell
3GPP does TS not LBFD-002009
initiating
system
If this ID. cell
parameter For is NO NO No
T5
need means
Indicates
36.331. to be 0.5,
the and LBFD-00201803
reselection
details,
set to see
NOT_CFG, but
3GPP a LBFD-001001
so on. For details,
configured
CDMA2000 with
1xRTT the LOFD-001035
lower
TS
the probability
36.331.
cell does not of LBFD-002009
see
1xRTT
network 3GPP ID. TS
parameters. For NO NO No
ping-pong
need to see be 3GPP LBFD-00201803
36.331.
details,
reselection.
configured For the
with LOFD-001035
TS 36.331.
details, see 3GPP
registration
TS 36.331. for CS
parameters
fallback to
CDMA2000 1xRTT.
Indicates the
1xRTT-specific LBFD-001001
multiple system ID LBFD-002009
Indicates NO NO No
storage isthe allowed. LBFD-00201803
1xRTT-specific
For details, see LBFD-001001
LOFD-001035
multiple
3GPP TSnetwork36.331.ID LBFD-002009
Indicates NO NO No
storage isthe allowed. LBFD-00201803
1xRTT-specific
For details, see LBFD-001001
LOFD-001035
home
3GPP registration
TS the 36.331. is LBFD-002009
Indicates NO NO No
allowed. For details, LBFD-00201803
1xRTT-specific
see 3GPP TS SID LBFD-001001
LOFD-001035
roamer
36.331. registration LBFD-002009
Indicates NO NO No
is allowed.the For LBFD-00201803
1xRTT-specific
details, see 3GPP NID LBFD-001001
LOFD-001035
roamer
Indicates
TS 36.331. registration
the LBFD-002009
NO NO No
is allowed. For
1xRTT-specific LBFD-00201803
details, see 3GPP LBFD-001001
LOFD-001035
parameter-change
Indicates
TS 36.331. theis LBFD-002009
registration NO NO No
1xRTT-specific LBFD-00201803
allowed. For details, LBFD-001001
power-up LOFD-001035
see 3GPP TS LBFD-002009
registration
36.331. is NO NO No
Indicates the details, LBFD-00201803
allowed. For LBFD-001001
1xRTT-specific LOFD-001035
see 3GPP TS LBFD-002009
registration
36.331. period. NO NO No
Indicates thesee LBFD-00201803
For details, LBFD-001001
1xRTT-specific LOFD-001035
3GPP
Indicates TS the 36.331. LBFD-002009
registration zone. NO NO No
1xRTT-specific LBFD-00201803
For details,
Indicates see
whether LBFD-001001
number of36.331. LOFD-001035
3GPP
the TS
1xRTT-specific LBFD-002009
registration
long codewhether zones
state NO NO No
Indicates the length LBFD-00201803
to be retained.
needs to be set.For LBFD-001001
of
the the 1xRTT-
parameters LOFD-001035
details,
When see
this 3GPP LBFD-002009
specific
applicable
TS 36.331. zone only timer.
for NO NO No
parameter isseesettoto LBFD-00201803
For details,
cell reselection
CFG, LOFD-001035
3GPPthe
CDMA2000 TS cell 36.331. needs
1xRTT LBFD-001001
to
needbe configured
to bethe set. If NO NO No LBFD-002009
Indicates
with the long code LBFD-00201803
this parameter
1xRTT-specific is
long LBFD-001001
Indicates
state.
Indicates
set to When
CFG, the
whether
thecell
this cell
code state.
reselection
parameter For
isduration
set to NO YES No LBFD-002009
speed-dependent
needs to be
details,
of GERAN
NOT_CFG, seecell 3GPP
the cell LBFD-00201803
scaling
configured parameters
with the LBFD-001001
TS
does 36.331.
reselection.
not need When to be
need
Indicatesto
parameters be theset
relatedfor NO NO No LBFD-002009
the
cell
to signal
configured
reselection
cell quality
reselectionwith to theof
to LBFD-00201803
duration
the serving used cell iniscell
long
CDMA2000code state. 1xRTT. LBFD-001001
reselection
lower to low
this than
When
If
CDMA2000 the the
parameter 1xRTT. is NO NO No LBFD-002009
priority
parameter
set to reselection
NOT_CFG, isseeset to LBFD-00201803
Indicates
For details, the LBFD-001001
threshold
CFG,
the cell the does all the
system not
scaling
3GPP TSfactor 36.331. NO NO No LBFD-002009
time
supportsand the
the signal
need to be
applicable to speed-
cell LBFD-00201803
of the new cell
dependent
configured scaling
with is
reselection
Indicates the of the LBFD-001001
higher
parameters.
parameters than the
When
related low
medium-mobility
scaling factor NO NO No LBFD-002009
priority
the reselection
parameter
to celltoreselection
UEs
applicable
threshold
CDMA2000to the
all cell set
is to LBFD-00201803
to NOT_CFG,
CDMA2000
1xRTT. For the
1xRTT.
details, LBFD-001001
reselection
Indicates
time, and of
whether
the not high-
UE
system
Indicates
see 3GPP does the
TSto NO NO No LBFD-002009
mobility
to set
stays the
in UEs
the speed-
current
support
Indicates
scaling
36.331. the
factorthe speed-
local LBFD-00201803
CDMA2000
dependent
serving cell 1xRTT.
scaling
for
dependent
ID of
applied
For the
details,
parameters to scaling
cell.see It
related
more thanidentifies
1s, thena YES YES No LBFD-001001
parameters.
uniquely
TReselGeran
3GPP
to cell TS 36.331.
reselection for to
the
cell UE
Indicates
within is the
medium-mobility initiating
a BS.
GERAN. LBFD-001001
cell
scaling
UEs. reselection
factor
If this The
request
applied parameter actual cell
to the
to new is NO NO No LBFD-002009
reselection
set to CFG, time
the for LBFD-00201803
LBFD-001001
cell. The lowerfor
TReselGeran
medium-mobility the
system
parameter
high-mobility supports
is, the
UEs. LBFD-002009
UEs to GERAN is NO NO No
the
easier
The speed-it is for
actual cellthe LBFD-00201803
equal
dependent to scaling LBFD-001001
LBFD-002018
UE to
reselection
TReselGeraninitiate timecellfor LBFD-002009
parameters.
reselection.
high-mobility IfUEs
this to NO NO No
multiplied
parameter by
is set to LBFD-00201803
However,
GERAN
TReselGeranSfMed istheequal Ping- to LBFD-001001
LBFD-002018
NOT_CFG,
Pong reselection
TReselGeran the LBFD-002009
ium.
system does NO NO No
probability
multiplied
The value is not
by LBFD-00201803
support
increased. the
TReselGeranSfHigh Thespeed- LBFD-002018
T_RESEL_SF_0DO
dependent scaling
.higher
Themeans
T25 the a
value
parameters.
parameter
T_RESEL_SF_0DO is, the
scaling factor of
harder
T25
0.25, meansit is for
a the
UE to initiate
scaling factor cell
T_RESEL_SF_0DO of
reselection.
0.25,
T5 means 0.5, and The
Ping-Pong
T_RESEL_SF_0DO
so on.
time and the signal
of the new cell is
higher than the low
priority reselection
threshold all the
Indicates
time, and whetherthe UE
Indicates
to set thethe the
speed-
stays
Indicates
scaling in the
factor current
local
dependent
serving cell scaling
for
ID of
applied the
parameters to cell. It
related
more thanidentifies
1s, thena YES YES No LBFD-001001
uniquely
TReselUtran
to cell reselection for to
the
cell UE
Indicates
within is the
medium-mobility initiating
a BS.
UTRAN. LBFD-001001
cell
scaling
UEs. reselection
factor
If this The
request
applied parameter actual cell
to the
to new is NO NO No LBFD-002009
reselection
set to CFG, time
the for LBFD-00201803
LBFD-001001
cell. The lower
TReselUtran
medium-mobility forthe
system
parameter
high-mobility supports
is, the
UEs. LBFD-002009
UEs to UTRAN is NO NO No
the
Thespeed-
easier it is for
actual cellthe LBFD-00201803
equal
dependent to scaling LBFD-001001
LBFD-002018
UE to initiate
reselection
TReselUtran timecellfor LBFD-002009
parameters.
reselection.
high-mobility IfUEs
this to NO NO No
multiplied
parameter byis set to LBFD-00201803
However,
UTRAN
Indicates
TReselUtranSfMedi the
isthe equal Ping-
offsetto LBFD-001001
LBFD-002018
NOT_CFG,
Pongthe reselection
TReselUtran
to minimum RX the LBFD-002009
um.
system does not NO NO No
probability
multiplied
signal
The level.
value byisThis LBFD-00201803
support
Indicates
increased. the
TReselUtranSfHigh.
value is the
also speed-
The local
used LBFD-002018
T_RESEL_SF_0DO
Indicates
dependent
ID of the the
cell.scaling
It for
higher
The
in
T25 thevalue
minimum meanstherequired
evaluation a YES YES No LBFD-001001
parameters.
uniquely
parameter
T_RESEL_SF_0DO
cell selection. identifies
is, theThis a
scaling
RX
cell signal
within factorlevel
a BS.of
harder LBFD-001001
T25 initthe
0.25,means
parameter
used is isfor
a the
UE NO NO No LBFD-002009
evaluation forcell
to
scaling
considered initiate
T_RESEL_SF_0DO factor only of
cell
reselection.
0.25,
when the cell Theand LBFD-00201803
T5 means
selection. 0.5,
For LBFD-001001
Ping-Pong
T_RESEL_SF_0DO
selection
so on. see
details, is 3GPP
reselection NO NO No LBFD-002009
T5 means
triggered
TS 36.304. by 0.5, and
Indicates
probability, the local LBFD-00201803
so on. searches
periodic
ID
for of
however, the cell. is It
higher-priority YES YES No LBFD-001001
uniquely
Indicates
reduced.and
PLMNs identifies
the UEa
whether
cell
the withinby
mapping
is served a BS.
afrom
Indicates LBFD-001001
SIBs
Visited SIthe Land
to Public NO NO No
transmission LBFD-002009
messages
Mobile Network is period
for system
enabled.
(VPLMN) the
Indicates cell. For LBFD-001001
information block NO NO No
details,
transmission see 3GPP LBFD-002009
type 2 (SIB2).period For
TS
for 36.304.
system
details,
Indicates see the 3GPP LBFD-001001
information
TS 36.331. block NO NO No
transmission LBFD-002009
type 3 (SIB3).period For
for system
details, see 3GPP
Indicates the LBFD-001001
information
TS 36.331. block NO NO No
transmission LBFD-002009
type 4 (SIB4).period For
for system
details, see 3GPP
Indicates the LBFD-001001
information
TS 36.331. block NO NO No
transmission LBFD-002009
type 5 (SIB5).period For
for system
details, see 3GPP
Indicates the LBFD-001001
information
TS 36.331. block NO NO No
transmission LBFD-002009
type 6 (SIB6).period For
for system
details, see 3GPP
Indicates the LBFD-001001
information
TS 36.331. block NO NO No
transmission LBFD-002009
type 7 (SIB7).period For
for system
details, see 3GPP LBFD-001001
information
TS 36.331. block NO NO No
LBFD-002009
type 8 (SIB8).
Indicates the local For
details,
ID of the
Indicates the seecell. 3GPPIt
TS 36.331.
Indicates the targeta YES YES No LBFD-001001
uniquely
compensation identifies
UE
cell transmit
factor within
for path power
a BS. loss. LBFD-001001
for
It isthe
used PUCCHin UL NO NO No LBFD-002009
Indicates
expected the
by the target
power
UE control.
transmit powerFor LBFD-002026
eNodeB
details, on 3GPP
see LBFD-001001
for the PUSCH
condition that NO NO No LBFD-002009
TS 36.213.
expected
normal by the LBFD-002026
eNodeB
demodulation on can LBFD-001001
condition
Indicates
be performed. that
the Delta For NO NO No LBFD-002009
normal
value
details, see 3GPP LBFD-002026
demodulation LBFD-001001
TS 36.213. can
corresponding to
NO NO No LBFD-002009
Indicates
be
PUCCHperformed. the Delta
format For
1.
value
details, see see 3GPP LBFD-002026
For details, LBFD-001001
corresponding
TS
3GPP 36.213.
TS 36.213. to
NO NO No LBFD-002009
PUCCH format 1b.
LBFD-002026
For details, see
3GPP TS 36.213.
Indicates the Delta
value
LBFD-001001
corresponding to
Indicates the Delta NO NO No LBFD-002009
PUCCH format 2.
value LBFD-002026
For details, see LBFD-001001
corresponding
3GPP TS the 36.213. to
Indicates length
Delta NO NO No LBFD-002009
PUCCH
Indicates format
the timer 2a.
of timer
value
Indicates 310.thesee For
timer LBFD-002026
For
value details,
Indicates of the3GPP
Timer 301. LBFD-001001
details,
corresponding
value
3GPP ofTSsee
Timer36.213. to
300.
preamble
For
TS details,
36.331. Delta
see NO NO No LBFD-002009
PUCCH
For details, format see 2b.
value
3GPP TS LBFD-002026
This
For details,
3GPP TS 36.331.
timer isseestarted
36.331. LBFD-001001
corresponding
This
when
3GPP
This timer
the
TS UE
timer is
is started
36.213.
started to
NO NO No LBFD-002009
message
when
detects
when the
the any 3.
UE The
UEfault sends
sends at
Indicates the local LBFD-002026
step
the is 2. For
RRCConnectionRe
physical
RRCConnectionRe layer.
ID of thesee
details, cell. It
The
quest. timer is 3GPP
estabilshmentRequ YES YES No LBFD-001001
uniquely
TS
est. 36.213. identifies a
stopped
Before theifthethetimer UE
Indicates
cell
Before within the atimer
BS.
timer
detects
expires,
value ofoneit is of 311.
Timer the LBFD-001001
expires.
following itifbefore
is NO NO No
stopped
For details, the
see UEthe LBFD-002009
stopped
timer
receives
3GPP TSif the (1)
expires: UE
receives
The either
physical-layer
RRCConnectionSet
36.331.This timer is LBFD-001001
NO NO No
RRCConnectionRe
fault
up oris rectified;
started when the(2) LBFD-002009
establishment
A handover
sends anisRRC
RRCConnectionRej
UE or
RRCConnectionRe LBFD-001001
triggered;
ect.
Connection (3) The NO NO No
establishmentRejec LBFD-002009
UE
Afterinitiates
the timer
Reestabilshment an RRC
t. The
connection
expires, the
Request timer is
UE
message. also LBFD-001001
Indicates
stopped if the
the name NO NO No
reestablishment
directly
Before
Indicates
of the cell. enters
thethe timer
The the LBFD-002009
selected
procedure.
RRC_IDLE
expires, it cell
isstate.
maximum
name is aan number
string of
becomes
After
stopped the iftimer the UE LBFD-001001
ofmaximum
a successive of"in 99 NO NO No
unsuitable
expires,
Indicates
selects the
an thecell.
E- UE LBFD-002009
sync"
characters.indications The
After
enters
maximum
UTRAN thethe timer
cell number
orbe inter-
received
string cannot from L1. all LBFD-001001
expires,
RRC_IDLE
of successive
RATcharacters
Indicates the
cell. whether UE
mode "out if NO NO No
null
enters the or LBFD-002009
Indicates
the security the modeUL
of
the sync"
After
Indicates the
cell is
contain
RRC_IDLE any timer
the of the is
indications
a Closedlocal
state.
cyclic
not
expires,
ID of
Subscriber prefix
activated.
received the thefrom
cell. length
UE
Group ItIfL1.the
following YES YES No None
of a
security
enters
uniquely
(CSG) cell.the
cell.A
mode cyclic
identifies
A CSG is a
characters:
Indicates the double
length
prefix
activated,
RRC_IDLE
cell can
within
has be
the
a aUE
state.
BS.
restrictions
quotation
of the DLan marks
cyclic ("),
common
initiates
on UEofaccess. or RRCIt
commas
prefix a (,),cell. A DL NO YES No None
extended
connection
broadcasts cyclic
a(;),
semicolons
cyclic prefix can be
prefix.
Indicates
specific An
reestablishment CSG extended
the(=), ID of
equal
a common
cyclic
procedure.
signs
prefixto orisID in
the
the sector
system
single quotation which NO YES No None
extended
generally cyclicin a
used
the cell('),
information
marks belongs. block
three
prefix.
complex An extended
(SIB)
consecutive
cyclic and
prefix is only plus
environment with a NO NO No LBFD-002009
those
signs
generally UEs
(+++), of
used the
two inora
strong
group multi-path
can access LBFD-002009
more consecutive
complex
effect
the CSG andcell. longThe LBFD-001004
blanks,
environment and two with or NO NO No
delay.
value In a cell, thea LBFD-00100401
more
strong consecutive
multi-path
UL cyclic prefix
BOOLEAN_FALSE LOFD-001031
LBFD-001004
percentage
effect
Indicates and signs
long
the
length
indicates canthat beUL the NO NO No LBFD-00100401
(%).
delay.
EARFCNfrom
Indicates In a cell,
of the
the the
cell.
different
cell is not a CSG the LOFD-001031
UL
It is cyclic
optional,
frequency
DL one. In prefix
band
addition, of
cell,
length
dependingand can thebeon value
the
the cell.
UL or For DL details,
cyclic NO YES No LBFD-002009
BOOLEAN_TRUE
Indicates
different
setting the of
from
of3GPP UL
the
see
prefix thelength TSa
indicates
Indicates
bandwidth
DL
EARFCNone. In that
whether
of the
the
addition,
36.104.
cell ismust be the
cell
to
cell,
the UL a
configure
which
configuration CSG
orthat DL isthe cell.
based
cyclic UL NO NO No LBFD-002009
same as of the
EARFCN
on the
prefix
indicator number
length of the of of
acell.
cell using the same
RBs.
cell IfFor
must it is
(UlEarfcnCfgInd).
LBBP. be settheto If
details,
CELL_BW_N25, NO YES No LBFD-002009
same
the value
see 3GPPtheas that
of of the
this
TSDL
Indicates
the
cell UL
using bandwidth
the same of
parameter
36.211. is not
bandwidth
EARFCN
the
LBBP. cell is
For of
25ofthe thecell.
RBs.
details, If
specified, the NO YES No LBFD-002009
cell.
For
itdefault
seeis setIt istobased
details,
3GPP see on
TS the
UL EARFCN
the
3GPP number
CELL_BW_N50,
36.211. TSwhich of RBs.
36.104.
is used, is LBFD-001003
If
thethis parameter
UL bandwidth isof NO YES No
calculated based on LBFD-002009
set
the tocell is 50 RBs.
DL EARFCN.
CELL_BW_N25,
The mapping
For details, see LBFD-001003
the bandwidthvalue
between of NO YES No
3GPP TSthe 36.104. LBFD-002009
the
of this parameter If
cell is 25 RBs.
itand
is set
the to actual
CELL_BW_N50,
number of RBs can
the bandwidth of
be deduced
the cell isFor
similarly. 50 RBs.
For
details, see see
details, 3GPP
3GPP
TS 36.104. TS 36.104.
Indicates the ID of
the E-UTRAN cell.
This parameter and
the eNodeB ID
constitute the E-
UTRAN cell identity.
NO YES No LBFD-002009
The E-UTRAN cell
Indicates
identity and thePLMN
Indicates
physical theID. For
cell
identity
additional constitute NO YES No LBFD-002009
details,
the ECGI. seespectrum
For3GPP
emission,
TS 36.331. which
details,
restrictssee
Indicates thethe3GPP length
TS 36.413. NO NO No LBFD-002009
emission
of the timer
Indicates power
theused active ofto
the
stateUEs
determine of the in whether
the
cell.cell. It
For
to
consists
Indicatesdetails,
block aofthe see the
middle-
the NO NO No None
3GPP TS and
blocking-priority
activated
administration 36.101.
cell. If
deactivated
state, which states. can be
CellAdminState NO NO No None
Unblock, High is
set
block, to Middle block,
Indicates
CELL_MIDDLE_BL the duplex
or
mode Lowofblock. NO NO No None
OCK, the cellcell. the is
CELL_FDD
deactivated when
indicates
no user accesses the FDD
Indicates the ratio NO YES No LBFD-002009
mode,
the cell and
during theto
of UL subframes
CELL_TDD
period
Indicates
DL of
subframes
Indicates time
the cell-
the in a
indicates the ratio
TDD NO YES No LBFD-002009
specified
specific
TDD cell.
frequency-specific by
offset
For thisfor
of special UL
mode.
parameter.
the
details,cell. Itthe
forsee The cell
affects
offset
subframes to3GPP
is
the also deactivated
probability
TS 36.211.
frequency of the of
special
Indicates DLthe index NO YES No LBFD-002009
iftriggering
cell.the timer expires.
handover
of theIt logical
subframes is contained
in root
a TDD
from
in
cell.
sequence, the
theFor cell
associated
details, to its
which see
is
intra-frequency
Indicates
measurement
3GPPtoTS
used the
36.211.
derive speed
the NO NO No None
neighboring
flag
object
preamble of IEtheincell. cells.
the SetA
smaller
this value
parameter
measurement
sequence. Each this
of to
parameter NO NO No None
ULTRA_HIGH_SPE
configuration.
logical root It to
leads
a
ED higher
affects
sequenceif the theprobability.
cell is
For
used details,
probability
corresponds to ofsee
provide to a NO YES No LBFD-002010
3GPP
coverage
triggering
Indicates
physical TSroot 36.331.
for
the an
handover
ultra-high-speed
from the cell
preamble
sequence. format
For to theits LOFD-001007
railway.
intra-frequency
used
mapping Set
in the this The
cell.
between NO NO No
LOFD-001008
parameter
neighboring
preamble
logical rootformat tocells.of
HIGH_SPEED
For
a details,
sequences be
cell must seethe
and if the
cell is as
used toof the NO NO No LBFD-002010
3GPP
same
physical TSroot 36.331.
that
provide
cell using
sequences, coverage
thesee same
Indicates
for
LBBP. a Forthe
high way. radius
details, Set
3GPP TS 36.211. NO NO No LBFD-002010
of
thisthe
see cell. TS to
parameter
3GPP
Indicates whether
LOW_SPEED
36.211.
Indicates thethein
to configure
other scenarios.
customized NO NO No None
bandwidth UL cell
bandwidth.
customization.
Indicates
Bandwidththe
customized DLiscell NO NO No None
customization
bandwidth.
available only when
Bandwidth
the bandwidth is 10 NO NO No None
customization
MHz. is
Indicates
available only the latestwhen
Indicates
available
the bandwidth the state is 10 NO NO Yes None
of the cell instance.
information
MHz. of the
cell, including the
reason of the cell NO NO Yes None
setup failure and
Indicates
the information the latest of
setup time
the successful of the cell NO NO Yes None
cell.
activation.
Indicates the latest
setup type of the NO NO Yes None
cell.
Indicates the latest
remove time of the NO NO Yes None
cell.
Indicates the
energy saving
status
Indicates of the the cell.latest
There
remove type are four of the NO NO Yes None
states:
cell. RF
intelligent
shutdown,the
Indicates cellslot NO NO Yes None
intelligent
number of the
shutdown,
baseband low
power consumption NO NO Yes None
processing board
mode,
where
Indicates andthe
the cellRRU is
automatic
Indicates
configured.
topology for the power-off
the NO NO Yes None
at a specified
subrack
cell. number time.of
RRU0 used by the
Indicates
cell. The value the 255 NO NO Yes None
subrack
indicates that
Indicates number
the theof
RRU1
cell doestonot
quantity used be byuse the
cell. The
RRU0. in the
included value 255 NO NO Yes None
Indicates
indicates
Indicates the
that
the local the
measurement
interval
cell does
ID of the between
not
cell. use
It
report after a DL YES YES No None
periodic
RRU1.
uniquely identifies a
ICIC measurement
Indicates the
measurement
cell within a BS.
event
maximum is triggered.
number
reports that are LBFD-00202201
The
of quantity
cells to a beDL can be NO NO No
sent after ICIC LOFD-00101401
RSRP
included
Indicates and in
the RSRQ.
measurement
Indicates the in the event
The
quantitymeasured
measurement used LBFD-00202201
is triggered.
number of For
periodic NO NO No
RSRP
reports
evaluation values
after aaare
DL LOFD-00101401
details,
measurement seeof3GPP DL
stable,
ICIC varying little
measurement
TS
reports36.331. after atime-
DL LBFD-00202201
with
eventthe
Indicates
event. isTheload,
the
triggered. and
quantity NO NO No
ICIC
thereforemeasurement
to-trigger
For details,
can be RSRP there
for seethe orisDL LOFD-00101401
event
little
ICIC
3GPP
RSRQ. is
signal triggered.
measurement
TS The 36.331.
Indicates the LBFD-00202201
For
event. details,
fluctuation.
measured When see
The
RSRP NO NO No
hysteresis for the LOFD-00101401
3GPP
measured
detecting
values
Indicates TSare 36.331.
RSRQ
thatstable,the
DL ICIC the switch
values
signal
varying
for forcibly
measurement vary
quality
little within
with
entering the
the LBFD-00202201
Indicates
load
serving but theand
are
cell offset
likely to
that NO NO No
the
event. load,
low and
power
This LOFD-00101401
foratthe
reflect
in leastDL one
the ICIC
signal
therefore
consumption
parameter there
is is
mode.
used
measurement
quality
neighboring of the cell in
cell LBFD-00202201
little
When
to signal
prevent both this
frequent NO NO No
event.
real
meet time.
theIf thisIf this
entering LOFD-00101401
fluctuation.
switch
triggering andofthe The
event
parameter
parameter
condition, is
isdue
the set
set
UEto to
to
measured
functionality
evaluations RSRQswitch LBFD-00202201
a large
BOTH,
does not value,
the sendactual the
a NO NO No
values
are
radio set vary
to ON, with the the
signalsignal
quantity quality of the LOFD-00101401
cell but to
measurement
loadenters
fluctuations. arethebelikely
For used
low to
neighboring
is the
report same
to the cell
as the
reflect the
power
details, signal
consumption LBFD-00202201
must
DL
eNodeBICIC
Indicates besee 3GPP switch NO NO No
quality
mode
TS as
36.331. of soon
the cell as in LOFD-00101401
significantly
Indicates
measurement
immediately.
for the thebetter
functionality local
real
the time.
wait time for
than
ID of that
trigger
Instead,
of the the ofpower
cell.
quantity.
low the the
UE It For
entering the mode YES YES No LOFD-001040
serving
uniquely
details,
sends
consumption a cell
see
report before
identifies
3GPP onlya
mode.
elapses, regardless
a
TS DL
cell
when
The ICIC
within
36.331.
cellthe can a
signal BS.
enter
of whether it is
measurement
quality
the lowthe continuously
power event NO NO No LOFD-001040
within low
can be
Indicates
meets the
consumption triggered.
the start
entering
mode
power consumption
For
time details,
condition
only of the
when see the
low
during
this
period. When the
3GPP
power TS 36.331.
consumption
time-to-trigger.
parameter isswitch
set to NO NO No LOFD-001040
functionality
Indicates thestop stop
mode.
ON
is setand toIfthethe
specific
ON but this
time
time of
is is earlier low
conditions
switch
power set are
consumption tothan
met.
OFF, NO NO No LOFD-001040
or
the the
cell same
enters asthe the
mode.
start time,If the the stop stop
low
time power
is
Indicates
time is earlier
consumption
the than
assumed mode to NO NO No LOFD-001040
or
be the
duration
a timesame in of as
which
the the
as
start soon
time, asthe thestop wait
the
next transmit
day. power
time
Indicatesfor
timeservices entering
is assumed the the
for is to NO NO No LOFD-001040
mode
duration
be a elapses,
time in of which
the if a
reduced in the cell
Mains
the Input
reference
next
in low day.power signal
Abnormal
transmit
Indicates poweralarmis
the NO NO No LOFD-001040
consumption mode.
indicating
reduced
duration in which in an the cell
absence
in
RFlow power
channels of AC are
power
consumption supplies mode.is NO NO No LOFD-001040
shut down in the
reported
cell in low power within the
low power mode.
consumption
consumption
period.
a cell automatically
takes the following
Indicates
actions in the
percentage
sequence: 1.oflowers the
transmit
the transmit power power for
services
for services; 2. to the total
transmit
lowers the power transmit for
services
Indicates
power of reference when
the the
NO NO No LOFD-001040
low
amount
signals;
Indicatespower by
3.the which
shuts
consumption
the reference
down
Allocation someand RF mode
signal
is implemented
transmit power
channels;
Retention 4. shuts
Priority by
is NO NO No LOFD-001040
means
reduced
Indicates
down the
(ARP) of in
threshold reducing
the the
carriers. cell for
the
in low transmit
Allocation
This
the power
duration
Silver-level and power
Indicates
for services. the NO NO No LOFD-001040
consumption
Retention
smooths
services.
admission the
A Prioritymode.
service
threshold
Indicates
Indicates
(ARP) threshold the
the offset
local for
transition
is
for
for defined
the from
handed-over
admission as a ofthe
cell
the
Indicates
normal ID.
Silver-level It
Golden-level
mode uniquely
the to
service the
service
new with QCI of
Gold-level YES YES No LBFD-001001
identifies
ifservices.
admission
low power Aathe cell
service
threshold
1.its
Indicates
This
services. ARP value
threshold
The offset
valueis
within
is
for
for defined
the
consumption
smaller a BS.
handed-over
admission than as a
ormode
of LBFD-001001
applies
of to
this parameter
Indicates both
the UL
Golden-level
service
for
equal
new
and the
Indicates with
tocell.the
Silver-level
DL. the IfQCIthe
value
offset of NO NO No LBFD-002023
applies
admission
service in
if itsboth
threshold
ARP UL LBFD-002024
2.
of This
conditions
this
services.
If
for the threshold
parameter for
The Gold-
satisfaction
admission the
value
of
and
for
value DL.
the is New
handed-over
smaller LBFD-001001
applies
cell
and
of
rate to
this
Indicates
new is
of to
enter
larger
parameter
services
Bronze-level both
the the
than ULlow
with
level
service
than services
this with
threshold.QCI and of NO NO No LBFD-002023
and
power
the
applies
QCI
admission
services. DL.
value consumption
in
of 1threshold
is of
Theboth
above
threshold UL
value or
handed-over
3.
The This service priority LBFD-002024
If
modethe
equal
for
of this the satisfaction
are
GoldServiceArpThd
and DL. to New
this no longer
handed-over
parameter Silver-
services
applies
has a to
negativewith both QCI UL N LBFD-001001
rate
.met
threshold,
service
applies of
during
A service
level services
services
with
in both this
is
the QCI and with
UL of NO NO No
can
and be
DL.
correlation admitted with if
theor LBFD-002023
QCI
period
defined of of
handed-over
4.
and This DL. 2threshold
asis
time,
New aabove the
both
If
ARPthe the following
satisfaction
value.
equal
cell
service
applies will
Bronze-level
services
Bronze-level to this
notwith
with
to both enter
QCIQCI UL ofN
conditions
rate of services are met:
with LBFD-001001
threshold,
the
service
can
1 can low
be power
if its
admitted the ARP if NO NO No
and
services
(1)
QCI Theofbe
DL.
handed-over
consumption
admitted.
and
3satisfaction
is above mode; or LBFD-002023
value
both
If theof
handed-over
rate isservices
the larger
following
satisfaction than
with
equal
service
otherwise, to this
with QCI
it this
enters of
the
rate
servicesvalue
conditionsof services ofare
with met:
with LBFD-001001
QCI
threshold,
2
thecan
N is
low be theQCI
higher
admitted.
power
N NO NO No
parameter.
(1)
QCI
can
than The
Indicates of
be 1
4 is
admitted
or equal The
satisfaction
below
above
the to the if or LBFD-002023
handed-over
If thethreshold,
consumption satisfaction mode
service
rate
this
equal
both
sum
congestionof
the
of priority
toservices
this
following
this offset has
thewith
service
rate
and of
the with
services
preceding QCI withof LBFD-001001
a
QCInegative
conditions
and
threshold N
handed-over
threshold,
the is higher
the
are met:
admission
for NO NO No
3
QCIcan
actions of be 2 are admitted.
is below
taken LBFD-002023
correlation
than
Indicates
service
handed-over
(1) The
threshold
services
If the
or equal
with the with
satisfaction
with
satisfaction for QCI to the
the
QCI ofin
the of
this
sequence.
ARP
sum
1 cannot
service
rate threshold,
congestion value.
of
of this
withbe
services offset
QCI thewithof
handed-over
1.
rateThis of threshold
services with LBFD-001001
handed-over
andcanthe
threshold
admitted.
4 admission
for NO NO No
QCI
services
applies
QCI
Indicates
service ofbe
N is to
3with admitted.
higher
with
is both
the below QCI UL LBFD-002023
threshold
services
If the
than
N;
and (2) or
DL. The with
satisfaction
equal forQCI the
QCI
tothe ofof
the
this
2 cannotthreshold,
congestion be
handed-over
2.
rate
sum This
theof
satisfaction
If threshold
services
ofsatisfaction
this offset rate with of LBFD-001001
handed-over
threshold
admitted. for NO NO No
services
applies
QCI
and
services
rate
Indicatesthe
of to
of services
4withwith
istheboth
admission
with below QCI
any UL
with LBFD-002023
service
services with QCI QCI ofof
N;
and
this
other
QCI (2)
thresholdDL.
congestionof The
threshold,
QCI1 in for
isthe the the
higher cell
3
3. cannot
Thissatisfaction be
threshold LBFD-001001
satisfaction
If the
handed-over
than
becomes
threshold theto lower for rate of NO NO No
admitted.
applies both UL LBFD-002023
services
rate
service
services of
corresponding
than
services this with
services
with
withQCI
with
threshold, any
QCI
QCI withofof
and
other
QCI
4 cannot DL.
of QCI2 in isthe higher
bethreshold cell
N;
4. (2)
admission
the This The
services threshold with LBFD-001001
If thethe
than
becomes
admitted. satisfactionlower NO NO No
satisfaction
for
QCI
appliesthe handed-over
of the1toenter bothratethe UL of LBFD-002024
rate of
corresponding
than this services
threshold,
services
congested
and DL. with state. any
that
with
admission
the QCI ofthreshold
services 3within the LBFD-001001
other
QCI.
If the QCIthe is higher
Ifsatisfaction NO NO No
cell
for
QCI becomes
theof handed-over
2 enter lower
than
rate
than
the
satisfaction
of
thisservices ratethe
threshold, of
with LBFD-002024
services
congested
corresponding
services
QCI of 1
4 with
with
in state.
the that
any cell
Indicates
the
QCI. servicesthethe
Ifsatisfaction rate
with LBFD-001001
If
QCIthe
admission
becomes is lower threshold
higher
lower than its NO NO No
reduction
QCI of
satisfaction 3 proportion
enter rate the of LBFD-002024
rate
for theof
corresponding
than the
thisservices
handed-over
sum
threshold, of with
this
for Gold-level
congested
Indicates state. GBR
services
QCI
Indicates
services
admission
threshold
the of 2 with
services inthe
with
the
andthe rate
any
that
threshold
withthecell LBFD-001001
services.
If
QCIthe
reduction is lower When
satisfaction proportion
than its NO NO No
becomes
threshold
QCI.
for If the
handed-over
congestion
QCI of 4 higher
forrelief
enter high the LBFD-002024
congestion
rate
for of services
Silver-level
corresponding occurs, with
GBR
than
PRB the
usage
satisfaction
services
offset, sum
with by
rate of
thatGBRthis
of
congested
Indicates
the
QCI
services.
admission
threshold
services. of the
rate 3thatin
When
The
services
thestate.
andthe rate
the
thresholdthecell
value LBFD-001001
services
QCI,
with
If the
reduction
scheduling the
QCI with
new
of
satisfaction 1 any
leave
proportion NO NO No
becomes
congestion
for
of handed-over
congestion
this higher
occurs,
relief LBFD-002024
QCI
services
the
rate is parameter
lower
congested
of cannot
services than be is
its
for
than
the Bronze-level
algorithm
services
offset, the
rate
expressed the sum
that
withprovides
the
services
in of with
that this
corresponding
admitted.
state.
QCI
GBR
for ofservices.
4 inand
Gold-level theGBR cell
threshold
scheduling
QCI,
with
percentage the
QCI new
of 2and the
leave LBFD-001001
admission
becomes
When
services congestion threshold
higher
(except NO NO No
congestion
algorithm
Indicates
services
the
applies congested to the
cannot relief
provides
both ULbe LBFD-002024
for
than
occurs,
VoIP handed-over
the sum
the
services) rate ofGBR this
isthat
offset,
for
admitted.
state.
and DL. the
Silver-level
threshold If services
for
the lowMAC
services
threshold
the scheduling
product withand that
the LBFD-001001
with
services
PRB
layer QCI
usage
detects of
(except 3of
bythat GBR
leave
GBR NO NO No
QCI,
congestion
algorithm
and the
this new relief
provides
proportion. LBFD-002024
the
VoIP
the congested
services.
PRB services) The
usage is
valueby
services
offset,
for thecannot
Bronze-level
Indicates services
the be
state.
the
of
GBR product
this parameter
services of theis LBFD-001001
admitted.
with
GBR
priority QCI
services of
threshold 4 leave of NO NO No
GBR
expressed
exceeds and the this
in LBFD-002023
(except
the congested
low
proportion.
percentage VoIP
energy and
threshold,
state.
services)
efficiency isthe
ratiothe UL
applies
usage is toconsidered
both LBFD-001001
product
service. of
If GBR
the and NO NO No
and
to DL.
beproportion.
high. If the MAC
In value)
this LBFD-002023
this
priority
layer (ARP
detects that
situation,
of new GBR
theaPRB
services
service usage
are
is lower
not by NO NO No
LBFD-001001
than
GBR this
services threshold, falls LBFD-002024
admitted
the service if the
below
GbrUsageSwitchthe is not
released
threshold, during
thethethe
switch
low energy under
usage
RacAlgoSwitch is considered
efficiency
to be low. ratio
parameter
control in case is turned of
on.
congestion.
of a specific QCI
exits the congestion
state if the
satisfaction rate of
the service exceeds
the sum of this
Indicates
congestion the release
Indicates the
Allocation and
offset
threshold and the
for
Retention Priority LBFD-001001
congestion
deciding on NO NO No
Indicates
(ARP) the
threshold LBFD-002024
threshold
whether the forUL the for
threshold
preemption. forTheRB
QCI.
usage The service
is whose
high. LBFD-001001
deciding
services on This NO NO No
retains
threshold the applies LOFD-00102901
whether
ARP values the DL to
are
congestion
UL admission state if LBFD-001001
resource
larger
Indicates than block
the or (RB)
equal
the satisfaction
decision. Iffor theThis ULrate NO NO No LBFD-002023
usage
to the value
threshold
Indicates is high.
theof this
is
RB below
usage the sum
reported of LBFD-002024
threshold
parameter
deciding
threshold on applies
for are to
this
by congestion
the MAC layer LBFD-001001
DL admission
preemptible.
whether
deciding
release the
on UL
offset and RBis NO NO No LBFD-002023
above
decision.
usage this
is the If
low.DL the It
whether
the congestion LBFD-002024
threshold,
usage
applies oftothe theDL
UL ULRB LBFD-001001
resource
threshold block
for the (RB)
RB usage
reported is
Indicates
admission
usage
QCI. is by the
low. the
decision.
This NO NO No LBFD-002023
assumed
MAC
If the layer
maximum UL RB to isbe
number above
usage LBFD-002024
threshold applies to
high.
this
of threshold,
non-GBR
reported by thethe LBFD-001001
DL admission
DL RBlayer
services
MAC usage
(excluding is NO NO No LBFD-002023
decision. If is the below
assumed
IP
thisMultimedia
threshold, to be the LBFD-002024
usage of the DL RB
Indicates
high.
Subsystem
UL RB usage whether [IMS]is LBFD-001001
reported by the NO NO No
to enable that
services)
assumed or be
to disable
can low. LBFD-002023
MAC
Indicates layerthe is below
local
the
be RF channel
provided by a
this
ID threshold,
ofThe
the value cell. the
It of
intelligent
cell. shutdown YES YES No LOFD-001039
usage
uniquely of identifies
the DL RBa
function
this parameter
Indicates forthethe startiscell.
is
cellassumed
within a to
BS. be
RF
time channel
applied of to
RF both
channel UL
low.
intelligent
Indicates
and DL. the
intelligent shutdown
shutdown value NO NO No LOFD-001039
Indicates
canthe
that
for be the
performed
thecell. reference If stop
the in
time
the cell
signal
stop of
time RF
only
power ischannelwhen
is
earlier
intelligent NO NO No LOFD-001039
than or theshutdown
this parameter
increased by same is as
during
for
set the
the to
RF
startON cell.
channel and
time, If the the
stop
stop time
specific is
timeconditions
intelligent is earlier
shutdown NO NO No LOFD-001039
than
are met.
period.
assumed or The thetosame be a as
the
timestart
reference
of the time,
signal
next the day.
stop
power time is
Indicates whetherby
increases NO NO No LOFD-001039
assumed
the value the
Indicates to
specifiedbelocal a
to enable or disable
time
by of
thisthe cell. It day.
the
parameter
ID ofintelligent next to
the YES YES No LOFD-001042
ensure
uniquely coverage
identifies of
shutdown
Indicates functionstart a
the
cell cell.
within Ifthe this DL
for the
time
PRB of cellafor
cell.
offset BS.
Cell
parameter
intelligentintelligent is set to
shutdown NO NO No LOFD-001042
intelligent
stopping
Indicates the DL
a
canvalue
Indicates
be greater
the
performed stop than
shutdown.
shutdown
PRB usage ofIf the
3,
time
onlythe of value
when cell this3
stop
cell. time
The is earlier
threshold
Indicates
applies
intelligent
parameter inDL for
the
effect.PRB
issameUL to
set NO NO No LOFD-001042
than
starting
PRB or
thresholdoffsetthe for
intelligent
for as
shutdown.
ON start
the and specific
stopping time, If
intelligentthe the
shutdown
stopping
stop time of
intelligentthe
stop
shutdown
cell.
shutdowntime is
conditions
When isof are
ofthe
earlier
the
the
met.cell NO NO No LOFD-001042
than
assumed
is or
Indicates
equal the
to the
to same
the beUL DLa as
average
cell.
the
PRB The
start
usage UL
UL or
time, PRB DL
the
time
PRB
PRB of the next
threshold
usage forday.
usage
stop time
threshold
starting forof a cell
threshold
is
intelligent
for
NO NO No LOFD-001042
and
assumedits
starting inter-
stoppingintelligentintelligent
to be a
shutdown
frequency
shutdown and
of the the cell
time
shutdown
value ofofthe this ofnext the day.
neighboring
is
cell. When the is
equal to the cells sum NO NO No LOFD-001042
parameter.
lower than the
of the
average
Intelligent
ULUL PRB or UL
shutdown DL
or
PRB DL
usage PRB
threshold
usage usage
of a for
cell
of the cell
threshold,
starting is
intelligent
intelligent NO NO No LOFD-001042
and
stoppedits inter-
when the
shutdown
frequency of the
and the
average
local
value cell
of thisDL PRB
is started.
neighboring
usage of inter- cells is NO NO No LOFD-001042
parameter.
lower
Indicates than the the UL
frequency
Indicates
Intelligent theshutdownlocal
or DL
interval
neighboring
ID of thePRB between usage
cells
of the
threshold,
periodic cellcell. is It
intelligent YES YES No None
exceeds
uniquely
stopped
Indicates the
identifies
when
the DLthe a
shutdown
measurement
PRB
cell threshold
within of
a PRB thefor
BS.
average
maximum
local
reports cell UL
thatis number
started.
are LBFD-00202202
stopping
usage
of cells oftointelligent
inter-
beUL ICIC NO NO No
sent
shutdownafter aof the LOFD-00101402
frequency
included
measurement in event
cell.
neighboring
measurement cells LBFD-00202202
is triggered. For NO NO No
exceeds
reports
details, after seethe3GPP ULUL
a LOFD-00101402
PRB
ICIC usage
measurement
TS 36.331.
threshold
event for
is triggered.
stopping
For details, intelligent
see
shutdown
3GPP TS 36.331. of the
cell.
Indicates
measurement
policy the switch
of arranging
for
event. the
the priority of RACH
The quantity
users.
resource
can be RSRP
According to the or
adjustment
Indicates
RSRQ.
Max C/I The the
scheduling switch
Indicates the
algorithm.
that
Indicates
measured
policy, is used
the If
theRSRP
UEs thewith
to
quantity used in the
switch
control
number
values are of
good-quality is ofturned
whether periodic
stable, on,
to
evaluation a UL
RACH
enable
measurement
varying
channels resources
or
littledisable
are with in
ICIC measurement
the
UL
reports
the cell
adaptive
load,
Indicates
scheduled, are
afterand
the HARQ.
a
thus UL
time- the LBFD-00202202
event. The quantity NO NO No
adjusted
If thisbe
ICIC
therefore
to-trigger
spectral switch
measurementbased
there
for
efficiency the ison
isorset ULis LOFD-00101402
can RSRP
the
to
event
little
ICIC
very access
is
signal
measurement
high. Thetype
triggered. QoSand
RSRQ.
Indicates The theof LBFD-00202202
the
event.
of andnumber
ADAPTIVE_HARQ_
For details,
fluctuation. When
fairness see
The NO NO No
measured
hysteresis RSRP
for the LOFD-00101402
accesses.
SW_OFF,
3GPP
measured
detecting
among TS users, If
UL
36.331.
RSRQ
that thedata
the
values
UL ICIC are stable,
switch
is
signal
however, is
retransmitted
values vary
qualityturned
cannotwith in by off,
the
the
be
varying
measurement little with LBFD-00202202
the
serving
ensured.RACH
Indicates
non-adaptive
load but are
cell the
The resource
offset
likely
and Max that to NO NO No
the load,
event. This and LOFD-00101402
adjustment
for
in
C/I at the
synchronous
reflect least UL one
the
scheduling ICIC
signal
therefore
parameter there
is used is
algorithm
measurement
HARQ.
quality
neighboring
policy of
can isbe
If this
the switch
cell
cellused in LBFD-00202202
little
to signal
prevent frequent NO NO No
disabled.
event.
is
real
meet
to set to
time.
verify If
thethe this
If this
entering LOFD-00101402
fluctuation.
triggering of Theevent
HoRaSwitch:
parameter
ADAPTIVE_HARQ_
parameter
condition, is
isdue set
set to
to
measured the
maximum
evaluations capacity
RSRQ UEto
LBFD-00202202
Indicates
a large
SW_ON,
BOTH,
does
of the not value,
the
system. the
UL
send actualswitch
the
data a
The is NO NO No
valuessignal
radio vary with the LOFD-00101402
that
signal is
retransmitted
quantity used
quality
to to of
by the
measurement
fairest
load but
fluctuations. arebelikely
scheduling For usedto
control
neighboring
adaptive
is the
report
policy same
to
is the the
RR. random
cell
asWhen the
reflect
details, the signal
see 3GPP LBFD-00202202
access
must
eNodeB
RR isbe
synchronous
UL ICIC mode
used, NO NO No
quality
TS 36.331. of thethe cell in LOFD-00101402
during
significantly
HARQ.
Indicates
measurement
immediately.
system handovers.
If thebetter
this
capacity, switch
local
real time.
If
is
ID this
thanset
of the
trigger
Instead,
however, switch
that
to of
cell.
quantity.
theis thethe
UEisIt For
turned YES YES No None
details,aon,
serving
ADAPTIVE_HARQ_
uniquely
sends
smallest. cell
see thebefore
identifies
report 3GPP
Therefore, onlya
eNodeB
a UL
SW_SEMION,
cell
TS 36.331.
when
RR ICIC
within
is the
used instructs
a
signal BS. to
only
UEs tothe
measurement
adaptive use HARQ theevent non-
is LBFD-002025
quality
verify continuously
upper limit NO NO No
contention-based
is triggered.
triggered For LOFD-001015
Indicates
meets
of thewhen
the scheduling the
enteringtargeta
random
details,
UL
IBLER grant
condition
fairness of access
see
inisthe
during
the3GPPSINR the
mode
TS
adjustment during
36.331.
delivered
time-to-trigger.
system. In an
to NO NO No LBFD-002006
handovers.
HARQ
application
Indicates process
CqiAdjAlgoSwitch:
algorithm. Aeffects,
the greater
ratio that
Indicates
If
is this switch
previously the is
Indicates
parameter
thethe
of PFmaximum
percentage the
schedulingvalue switch
of free
turned
suspended off, the
due NO NO No LBFD-001006
Indicates
that
indicates
policy
bandwidth
shared is is used athe
between
RBs to to
greater
eNodeB
reasons
minimum
control
SINR
the instructs
such
adjustment
previous
resources interval
whether that twoastheto
occupied
UEs
resource to use bythe pay-
collision,
between
allow
value,
policies.
uplink theand two
eNodeB
Thus,
scheduler thus PF a NO NO No LOFD-00101502
free users of
contention-based
activation onathe
preallocations.
to adjust
higher-level
can be used
allocate theMCS to That
UE-
to is
PUSCH
random
measurement in
access gap,
is,
used. the
reported actual
verify the capacity,
preallocation CQI based
users
scheduling.
mode
and during
PDCCH The
interval
on
to thethe
coverage, between
Initial
total and Block
system NO NO No LOFD-00101502
other
handovers.
congestion. RBs on the
Setting
two
Error
Indicates
fairness preallocations
bandwidth. Rate ofthe (IBLER).
the data
PUSCH
UnsyncRaSwitch:
this parameter are
of
If one
this
amount
system.
Indicates
allocated
UE
switch must
According
whether
to is to be
set
Indicates
ADAPTIVE_HARQ_
longer
to On, than
the the
CQI or switch
equal NO NO No LOFD-00101502
preallocated
to
the the EPF When
Frequency
subscribers. to
that
SW_ON
to the isuser.
used
value helps to
ofswitch
Indicates
adjustment
each
scheduling
Hopping
capacity
the
(FH)
is policy,isthis
control
reduce
parameter.
used
algorithm
the to
features the
resource
enable
is random
such oras LBFD-002025
enabled, as
sufficient, thewell NO NO No
access
consumption
disable
enabled.
as user mode
change
QoS,In the due in to LOFD-001015
the type
percentage and of UEs RBs
applied
retransmission,
the
case,
system when
cell-specific
the eNodeB
capacity, LOFD-00101502
scheme
occupied ofby FH pay- if it is
are
increase
SRS
would
and out ofthe
subframe
adjust
channel cell
the NO NO No LBFD-002023
enabled.
free users and
synchronization
throughput,
configuration
UE-reported
Indicates
frequency the and (that
CQI
local
selection in LBFD-002024
those
Indicates
the
prevent occupied
uplink.
Indicates the
the switch
switchby
is,
based
ID
are the
of the adjustment
on
considered. the
cell. It The
pay
used users
isto enable will isreach YES YES No None
If
onthis
that
IBLER.
basic the
uniquely switch
retransmission used
setting to
identifies
scheduling oforthe a
the
disable
turned
enable preset
conflicts. the
on,
and values.
PUCCH
the
This, disable on
SrsSubframeCfg
If this
cell
policy switch
withinis used a is
BS. set
Changes
resource
eNodeB
the Active
other inQueue
instructs
hand, this will LBFD-001001
parameter).
to Off,
during the
the CQI NO NO No
parameter
adjustment
UEs
Management
increase to use affect
the
signaling non-the LBFD-002010
If the switch
adjustment
performance istest. In
relative
algorithm.
contention-based
(AQM)
overhead percentage
algorithm.
and
turned
algorithm
commercial on, is the
between
If
If the switch
random
this
therefore switch RBs
access
consume is for
is set
algorithm
disabled.
scenarios, Inyou this are NO NO No LBFD-001001
pay-free
turned
mode
to
more ON, on,
upon
the
PDCCH users PUCCH
AQMDL and
data
dynamically
case,
advised the to eNodeB
use adjusts the
those
resource
arrival
function
resources. for
in is pay
the users.
case
enabled
the
would SRS
EPF schedulingnot subframe
adjust the
Modifying
adjustment
of
to out-of-
prevent the
orisCQI value
control NO NO No LBFD-001001
configuration
UE-reported
policy. based
of this parameter
initiated
synchronization.
congestion. when the
on the on
based
for
usage
an switch
active theThe of
cell
cell
will
PUCCH
If this
length
resources.
IBLER. of resources
the is
PDCP
lead
are to the
insufficient re-setup or NO NO No LOFD-001027
turned
packet
If the switch
StepVarySwitch: off,
queue the isis
of the cell.
excessive.
eNodeB
maintained instructs
atswitch
a
turned
Indicates off, thethe LOFD-001002
If
UEsthisis
relatively
algorithm
that to switch
use
used small
uses the
tois the NO NO No LOFD-00101501
Indicates the switch
turned
initial to
enable tooff,
contention-based
value help
configuration
and thedisable LOFD-00101502
used enable or
PUCCH
random
achieve
andvariable-step-
the does resource
access
an not link
disable radio
adjustment
mode is NO NO No None
failure upon
appropriate
perform
based dynamic
adjustment
(RLF) DL
trade- data
disabled.
arrival
off between
Indicates
switching.
algorithm. in the
the case
switch
detection for UL
of
used
If out-of-
throughput
this
links. to enable
switch and is set time
or
synchronization. NO NO No LOFD-001025
latency.
disable
to On, the dynamicvariable-
MaksIdxSwitch:
If this switch
voltage
step-based adjustment. is set
Indicates
to OFF, the
adjustment the AQM switch
that is used
function
algorithm to
isisdisabled.
control
enabledreuse to of
dedicated
accelerate the
preambles
convergence betweenof
UEs. In this case,
IBLER.
Indicates
turned off,the inner- switch
can
based
effect.
scheduling
related beon admitted.
to the on theIf
loop power control
this
ACK/NACK
If
PDSCH. switch
frequency-priority- is
If this for turned
is not performed
off,
messages theinter-
InterFreqMLBSwitc
switch isnumber to a UL of
based
PUSCH inturned dynamic on,
PRBs
HARQ
h is set
power control
frequency used
process.
to ON, by the
is If
scheduling mode.
existing
PreAllocationSwitch
inter-frequency
applied
handover. GBR load
during
this switch is turned
:services
Indicates
balancing
semi-persistent
FreqPriorIFHOSwitc isiswhether
not
on, inner-loop
checked
to enable
enabled.
scheduling
h: Indicates during
If or on disable
the the LBFD-001001
power control is
admission
preallocation,
InterFreqMLBSwitc
PDSCH, ensuring
Indicates
frequency-priority- the which LBFD-002023
performed for NO NO No
evaluation
shortens
h is setinter-
BfSwitch:
communication
switches to the of end-
OFF,
Indicates thethe LBFD-002024
based
PUSCH inrelateddynamic to LBFD-001001
GBR
to-end
whether
quality
DL services.
inter-frequency delay
scheduling
frequency to
(indicated enableof inload by LOFD-00102901
schedulinghandover mode. LOFD-001032
LCEM_RAC_ALG_
services
balancing
or
IBLER)
the disable
switch. cell. of when
Frequency-is
the
VoIP the NO NO No
PhSinrTarUpdateS LOFD-001044
DL_LDC_SWITCH:
UL load isinlight.
disabled.
beamforming
services If
witch is the the
FreqSelSwitch:
priority-based switch inter- LOFD-001045
LBFD-002003
Indicates
preallocation
If UtranMlbSwitch the switch
is
algorithm.
QPSKtomodulation
Indicates
frequency
used enable theIf the
handover switch or is NO NO No LBFD-002009
for
set
switch
scheme.
used
is the
enabled,to algorithm
ON,
is
to PH-based
applicable the
turned
enable the when or of
on,
disable LBFD-002016
downlink
probability
UTRAN
UEs in
PhichInnerLoopPcS
disable
the eNodeB the loadload
frequency of
cell UEs can
SINR target
control.
entering
balancing
be
witch:served
selection
provides IfDRX
Indicates this
and
dualis
by is the
the LBFD-002009
updates in dynamic NO NO No
switch
relatively
enabled.
beamforming
PHICH inner-loop
scheduling.
coverage is turned
low
If and and
If this one on, LBFD-002026
scheduling mode.
downlink
therefore
UtranMlbSwitch
algorithm.
power
switch
frequency control
is turned theIf the
is does is
on,
This version TDLOFD-001049
congestion
service
set
switch
switch.
data to
preferred OFF,
istime
Iftheturned
this
is transmitted checks
the
forswitch of switchtheoff, NO NO No
not use TDLOFD-001061
are
UEs
UTRAN
is
on performed;
turned
the
carrying is relatively
the load
in frequency off,
services.cell only if If
and only reserves it
the
short.
the
band
this cell
balancing
cannot initial
with
switch is
betransmit is
served
good-
isbeing.
set to LBFD-002025
for the
Indicates time whether NO NO No
congested,
UlVmimoSwitch:
disabled.
by
power the
quality
On, the beamforming
for
channels. the
frequency- actions LOFD-001015
This
to enablefunction or is
disable
are taken
Indicates
If GeranMlbSwitch
algorithm.
PHICH
ServiceDiffSwitch:
priority-based is to
whether
The
set. relieve
Ifinter-
this LBFD-002025
incorporated
eRAN sharing into for
the
to
is setcongestion.
enable
beamforming
switch
Indicates
frequency to is ON, or
turned
the disable
handoverthe
switch Ifon, LOFD-001015
inner-loop
admission power
and NO NO No LBFD-001001
this
UL
algorithm
the
used switch
will MU-MIMO.
GERAN eNodeB
be load
totriggered
enable is turned
isPUSCH IforUL LOFD-001048 /
control
scheduling. for If this TDLBFD-001001
off,
MU-MIMO
controls
disable
even downlink
balancing
disabled when by
the
service isis default.
the LOFD-001016
in dynamic
switch is turned on, LBFD-002023 /
congestion
enabled,
enabled.
It must be
physical
differentiation.
serving the
channel
cell checks
Ifenabled If this NO NO No
scheduling
operators sharemode. TDLBFD-002023
are
eNodeB
transmit
switch
providesnotisperformed;
GeranMlbSwitch
manually selects
aif to
power
turned goodtoon, is
Therefore,
data channel LBFD-002025 /
therefore,
UEs
set to
required.
enable
service
signal forOFF, pairing
the receive
quality. downlink
the If this
enable
resources
Indicates this the function,
switch NO NO No TDLBFD-002025
LOFD-001032
congestion,
according
GERAN
Indicates
SINR load
toisconverge
differentiation
switch set toifto
the any,
pairing
band
isOff,
set
according
of the Then DL to the
cannot
rules.
Indicates
balancing
division
to the
applied.
the be
target
frequency- scheme
If therelieved.
is
this the local
SINR. pair
InnerLoopPuschSwi
specified
scheduling policy.
LCEM_RAC_ALG_
of
ID UEs
of
disabled.
used the transmit
cell. It
tch toinOn.
PdcchPcSwitch:
switch
priority-based
percentages.
According
isdownlink
turned
tosame
inter-
the a
off, YES YES No None
UL_LDC_SWITCH:
data
uniquely
If
ICIC.
Indicates
service
frequency on
CdmaMlbSwitch
The theidentifies
band
thehandover
InnerLoopPucchSwi
Max C/I in scheduling
Indicates
frequency-time
cell
is set within the
athe BS. switch
division
PDCCH
is
tch: If to
differentiation
disabled.
policy, this
the
ON,
power switch
UE
the cell
is
with isis
not LBFD-00202201
for
controlthe
resources,
CDMA2000
adjusted
applied. algorithm
switch.
FreqPriorIFBlindHO according load If of NO NO No
turned
good-quality off, inner- LOFD-00101401
uplink
increasing
balancing
to
this the
Switch: load
setting
switch Indicates control.
issystem
is of this
turned
Indicates
loop
channels power the
are local
control
If this
throughput
Indicates
enabled.
parameter
off,not
the power switch
frequency- Ifthe so
is and isoffset
thatfor
ID
is of
scheduled the
performed cell. andIt for
turned
spectral
of
the the
CdmaMlbSwitch
edge
allocated on,
DCI bandsuplink
efficiency.
power
evenly isa
to YES YES No LBFD-002016
priority-based
uniquely
PUCCH. identifies
If this inter-
hence
congestion
set to
neighboring the
TtiBundlingSwitch:
relative OFF, to spectral
the checks
the
cells do
PDCCH.
frequency
cell
switch within Ifablind
is turned thisBS. on,
efficiency
are performed;
Indicates
reference
CDMA2000
not overlap. is
whether
signal very
load if
switch
handover
inner-loop is turned
switch.
power on, If NO NO No LBFD-002016
high.
the
to
power cell
enable
balancing The is or
when QoS
isisdisable
the and
power
this
control switch allocated
is performed set to
to
Indicates
fairness
congested,
TTI
PDCCH
disabled.bundling. amongthe
channel local
actionsIf TTI
PDCCH
On,
for the
PUCCH. is adjusted
frequency-
ID
users,
are of
bundling
carries
If the
taken however,cell.
is
dedicated to It
relieve
enabled,
dynamically. inter-
priority-based
OiSinrTarUpdateSw YES YES No LBFD-002016
uniquely
cannot
the
more
control beidentifies
congestion.
transmission
IntraFreqIdleMLBSinformation.ensured. If a
frequency
Indicates
itch:
cell If this
within the
ablind
switch
BS. PA is
The
this Max
switch
opportunities
witch and C/I is turned
are
handover
value
turned ofoff, cell isthe center OI-
scheduling
off, uplinkIftothis
available
IntraFreqActiveMLB policy
UEs NO NO No LBFD-002016
enabled.
UEs
based when SINR DL targetICIC
can
Switch
Indicatesbethe
congestion
within used
are delay
the both to
checks PAOff, set
switch
is enabled.
update
Indicates isisset not
the to
verify
are
budget
to
valueON,not the
of the cell maximum
performed;
for VoIP
intra-edge
the eNodeBfor
performed
percentage of free NO NO No LBFD-002016
capacity
therefore,
services
frequency
UEs when ofuplink
on the
idle
DL theICIC air
load
decides
PUSCH
shared
Indicates RBswhether
in the dynamic local to
system.
congestion,
interface,
is enabled.
balancing The thereby
is if RR any,
perform
scheduling
occupied
ID of thebecell. the by mode.
pay-It isIf
scheduling
cannot
Indicates
improving
enabled. Ifthe policy
relieved.
uplink
either power
frequency-priority-
this
free switch
users onis turned
the a YES YES No LBFD-002016
uniquely
the fairest
LCEM_LDC_ALG_
offset
coverage.
switch
Indicates between identifies
isOI-based
settheto weight the
OFF,
based
on,
PDSCH
cell the
within inter-
in a BS.
scheduling
REL_DRB_SWITC
PHICH
Im2IcSwitch:
the
of the TX
intra-frequency
BT policy.
power
service
frequency
SINR
scheduling. target handover
update
The
When
H:
and Indicates
Indicates
idle
used the
load
in RR RS
EPF ispower.
whether
balancing the NO NO No LBFD-002016
based
is
otherperformed
RBson on for
the
adopted,
switch
This
to
is enable
disabled.
Indicates
scheduling. forthe
offset the
or
the isThe used
disable
local
measurements.
Indicates
PUSCH
PDSCH in
are the dynamic weight
smallest
algorithm
when
the
ID
value PHICH
ofsecond-order
the
of system
ofis power
cell.
this Itvalid
This
of the
scheduling
allocated switch
non-BT to mode.
pay YES YES No None
capacity
releasing
control
intermodulation
uniquely
parameter is is low the
disabled.
identifies
is used a
only when
service
users. used
When in
smallest.
energy
(IM2)
cell
in within
calculating Therefore,
efficiency
components a BS. the
FreqPriorIFHOSwitc
enhanced
capacity is only
RR
ratio is(EER)
elimination
priority used
of services
for UEs. to LBFD-002025
h is set
proportional
sufficient, to the On.
the UE
fair NO NO No
verify
in
When the
during the
case
data
schedulingupper of
is LOFD-001015
(EPF)
percentage scheduling. of RBsIt
bound
congestion.
transmitted
and of thein
therefore If thisboth LOFD-00101502
is used
occupied in byfairnesspay-on,
scheduling
switch
UL andisDL,
determines turned two IM2
the NO NO No LBFD-002023
calculating
free users andthe
in the
release
components
amount system.
of
of low physicalare In
EER LBFD-002024
scheduling
those occupied priorities by LOFD-00101502
terms
services
generated
resources of the
is toallowed
be
for
pay UEs
users and will reach NO NO No LBFD-002023
scheduling
in the case
symmetrically
allocated effect,
of
tovalues.
the UE
determines
the preset the LBFD-002024
the
beside
that PF
congestion. scheduling
the
requests If the
Direct this
amount
Changes of in this LOFD-00101502
policy
switch is
is between
turned
Current
BT service.to
resources
parameter
(DC) The
affect be off, BTthe NO NO No LBFD-002023
the
release previous
subcarrier
service of
priority low
on twothe EER
has
allocated
relative to the
percentage UE LBFD-002024
policies.
services
DL
a receive
positive Therefore,
is not channel
that
between requests RBs non-
for
PF
allowed
due canto
correlation be
the in used
the
with case to
the
BT services.
pay-free users The and
verify
of
value the
congestion.
interference of capacity, from
priority
those forofthis the non-
pay users.
coverage,
LCEM_RAC_ALG_
UL radio and
signals.
parameter.
BT service
Modifying the This
has valuea If
fairness
PREEMPTION_SW
this
parameterswitch of the
is
is turned
valid
positive
of this Indicates correlation
parameter
system.
ITCH: The theEPF
on,
only
withan
for
IM2when
the activevalue cell ofthe will
scheduling
switch
components
service for the policy
this
leadparameter.
to the re-setup This
Indicates the
threshold used in
triggering of intra-
Indicates
frequencythe load
threshold
Indicates the
balancing. forLoad local
Indicates
triggering
ID of the cell. the
inter- period
It
balancing between YES YES No None
of the
frequency
uniquely
Indicates inter-cell
theits loada
load
identifies
the cell and
exchange.
balancing.
cell
threshold
number within offor This
Load
aOFDM BS.
intra-frequency
parameter
balancing
triggering
symbols is
between
inter-RAT
initially LBFD-001001
neighboring cell is NO NO No
contained
the
load
occupied cell and
balancing. byinits the
the LOFD-001032
triggered
Indicates
Indicates only
the
the offset if the
load
PDCCH. exchange
inter-frequency
Load balancingIf the
cell
used
thresholdloadin the exceeds
of load LBFD-001001
request
neighboring
between
switch ismessage.
the
turned cell
celloff is If NO NO No
the sum
evaluation
difference of this
for
between LOFD-001032
this
triggered
and
to parameter
its
disabletoand only
inter-RAT
dynamic ifis the
threshold
whether the
two
specified
cell cells exceeds
load
neighboring
adjustment bytrigger
for load
the
tocell the is
LBFD-001001
offset,
load
balancing. and
balancing. is
IfthistheTo NO NO No LOFD-001044
source
the
triggered
number sumcell, of
of only
OFDM the if the
stopped
prevent
load if
load
difference the cell LOFD-001045
target
threshold
cell
symbols load cell reports
and
exceeds the LBFD-001001
load
Indicates
between fallsoccupied
fluctuations below
the
cells fromCCE this
its
the
by load
offset, sum
the andtoof
PDCCH, the
is
this this LOFD-001032
threshold.
frequently
ratio
exceeds adjustment triggering NO NO No
source
stopped
threshold
parameter ifthis
cell the
and at cell
indicates the LOFD-001044
or
switchstopping
threshold,
intervals on the
the
specifiedload LBFD-001001
LOFD-001045
loadnumber
offset,
the falls
and below
is of this
balancing,
PDCCH.
eNodeB
through If anthisoffset
determines
this LOFD-001032
threshold.
stopped
OFDM if
symbols the cell that NO NO No
needs
switch
that
parameter.load to
is setbeIfset.
imbalance to
this ON, LOFD-001044
load
are
That
the falls
always
is,and
resource below
a specific this LBFD-001001
LOFD-001045
occurs
parameter is the not
threshold.
occupied
load
allocation balancing byalgorithm LOFD-001032
therefore
specified initiates
by the NO NO No
PDCCH.
action
of iscell,
thebalancing
PDCCH If the only
taken LOFD-001044
load
source
Indicates thethe local
switch
ifIDthe
adjusts isthe
cell turned
load ratio on, LOFD-001045
between
target
the of thecell
default
thereports
cell. It of If
cells.
exceeds the YES YES No None
CCEs
the
its load
load
uniquely
Indicates
minimum
assigned thesum
todifference
identifies
the
number switch toofa
of
the
UL
between
source
cell
used corresponding
and
within those
cell
tosymbolscells
enableaatBS. falls
the or
OFDM
load
assigned balancing to DL 4 is
below this
protocol-defined
disable dynamic NO NO No LBFD-001001
for the
threshold
within 1.4
each andMHzthis
threshold,
default
adjustment the
intervals. onfor the
bandwidth,
offset.
Transmission 3 Time the
eNodeB of
number determines
OFDM
3 MHz
Interval bandwidth,
that load(TTI)
symbols imbalance
occupied based NO NO No LBFD-001001
and
on the2 for CCE theusages other
is
by resolved
PDCCH. If the and
standard
in UL and stops DL. If load this
therefore
Indicates
PhichDuration the
bandwidths.
switch is set If
to this
Off, NO NO No LBFD-001001
balancing
threshold
parameter between
forin the
parameter
the ratio is set to
Indicates
low
PHICHCfg load of
cells. the
state CCEs
MO local
ofisthe
a value
assigned
ID less to UL than and
SRIofto
Indicates
set the
resources. cell.
EXTENDED,the It The
time
YES YES No None
the
those
uniquely
when corresponding
assigned
the identifies
cell no- to a
SRI
the resources enter
dynamic
default
DL
cell
traffic is not
within minimum
detection a BS.
the low
adjustment
Indicates load the state
not if
is length
number,
Indicates
dynamically
starts. If the
thethe time
stop
the
performed
of PUCCH
the the timer evenforno- the NO NO No None
number
when
adjusted.
time isthe ofcell
earlier OFDM than
resource
when
Indicates
cell no-traffic allocation
switch
the local is
symbols
traffic
or the same occupied
detection as theis
algorithm
turned
ID of
detection. the on. detects
cell.
If It
there
by
stops.
start the IfPDCCH
time, the stop is YES YES No LOFD-002010
thattraffic
uniquely
no
adjusted
time
the
is inthe
number
identifies
earlier thethanend of a
cell
time
admitted
cell
within isthe
within assumed
UEsa BS.
duration is to
dynamically
or
be the
a than
timesame of starting
as the
the
less
specified the
by value
this NO NO No LOFD-002010
from
start
next the
time,
day. parameter
Ifthe the stop
of this
parameter, parameter. the to
value.
time
timer Ifassumed
isfor this
reporting
eNodeB
parameter
be timereports
ano-traffic ofisthe set the to
the
no-access alarm alarm NO NO No LOFD-002010
a
next
is value day.
notresets greater
set totheIf the
0, the than
and
the
timer corresponding
for performs
reporting cell.
eNodeB
If this parameter is
default
the
Indicates
the minimum
no-traffic the alarm
cell0,no-traffic band NO NO No LOFD-002010
set
number,
is not
divisionto set the
this
to
scheme cell
0, the no-
detection
Indicates
traffic detection fromlocal
the theis
number
eNodeB
used
start
ID of in
time
the isperforms
uplink adjusted
to
cell. the ItICIC.
Indicates
not performed. the indexIf
dynamically
the starting YES YES No None
The
stop acell
uniquely
of
the
band
time. no-traffic
simulated
timer
division
identifies
for loadin a
from
detection
the
cell the
cell
within is default
from
changed
a BS. the
configuration.
reporting the no-The
minimum
start number.
valuetime
according
traffic of
alarm thisto
to the the
is set to NO NO No
LBFD-00202202
stop
setting
parameter time. of this LOFD-00101402
a non-zerothe
Indicates
parameter sovalue,local
that
corresponds
the
ID of eNodeB
the cell. toIt do
the edge
SimuLoadCfgIndex bands YES YES No None
performs
uniquely
not the cell a
identifies
in a overlap
no-traffic
cell SimuLoad
within a BS.MO.
detection
between
That the is, each index
from
neighboring start time
cells. NO NO No None
corresponds
Indicates
to the stopthe time. to a
specific
transmission set ofmode
parameters
adopted by athat NO NO No None
Indicates
consistitute
simulated the
load one of
number
the multipleRBs
configuration. of
allocated
simulatedby load a NO NO Yes None
simulated
configurations load
configuration.
stored in the
eNodeB.
Indicates the
number of RBs for
NO NO Yes None
commercial
Indicates
services inthe thepowercell.
allocated by a
NO NO Yes None
simulated load
configuration.
Indicates the power
for commercial NO NO Yes None
Indicates
services inthe the cell.
number of UEs
Indicates the
allocated by a NO NO Yes None
modification
number of load period
simulated
coefficient
commercial for the
service
configuration.
BCCH.
UEs, that BCCH is, the NO NO Yes None
modification
number ofthe
Indicates UEsperiod
local that
=
are
ID Modification
ofactually
the cell.served It
period coefficient YES YES No LBFD-001001
by the cell.
uniquely identifiesxa
Default paging
cell within a BS.
cycle, where the
NO NO No LBFD-002009
BCCH modification
Indicates
period andthe local
default
ID of
paging the cell.
cycle It
Indicates
uniquely the are offseta
identifies
YES YES No None
measured
of the PCFICH in units
cell
of within
radio a BS. and
frames, LBFD-002003
transmit power
the modification
Indicates NO NO No LBFD-002009
relative tothe theoffset
period coefficient LBFD-002016
of the PBCH
reference signal is LBFD-002003
specified
transmit
power. power
Indicates by
thethis offset NO NO No LBFD-002009
parameter.
relative to
of the transmit the
LBFD-002016
reference
power
Indicates for the signal
the cell
offset LBFD-002003
power.
synchronization
of the transmit NO NO No LBFD-002009
signalsfor
power relative
broadcast to LBFD-002016
Indicates
the reference theonoffset
signal LBFD-002003
information the
of the transmit
power. NO NO No LBFD-002009
PDSCH channel
power LBFD-002016
relativefor
Indicates tothethe
theoffset LBFD-002003
paging
of the information
transmit
reference signal LBFD-002009
NO NO No
on
powerthe for
power. PDSCH the LBFD-002011
channel relative to LBFD-002003
LBFD-002016
random access
the reference LBFD-002009
responses on signal
the NO NO No
Indicates
power. channel the offset LBFD-002010
PDSCH
of the pilot power LBFD-002016
relative to the
relative to
reference signal the NO NO No None
reference
Indicates
power. the
Indicates signal
the local
power
power.
Indicates
ID of the
ramping step for the
cell. It
scaling YES YES No None
Indicates the indexa
uniquely
preamble factor
identifies
of
cellthe
reference Energy
within
transmission. a BS.
signal IfPer LBFD-002003
Resource
power Element
ofthrough
the NO NO No
access
Indicates the cell.
targetthe LBFD-002009
(EPRE)
For transmit
PRACH details,on
failsthe
seeafter LBFD-002016
UE power
PDSCH.
3GPP This LBFD-002003
for the TS
several 36.213.
attempts,
PRACH
scaling
the powerby factor rampingis NO NO No LBFD-002009
expected the
determined
Indicates
step the bylocalthe LBFD-002016
eNodeB whenbe
needs to
value
ID of this
of thepreamble
increased cell. It
to ensure
PRACH YES YES No LBFD-001001
parameter
uniquely
successful and
identifies
access the a
format 0 is applied
antenna
cell
of thewithin
Indicates port.
a
UE.thethat BS. For
SRS
on condition LBFD-001001
details,
For example,
subframe see 3GPP the NO NO No
requirements for LBFD-002002
TS
value 36.213. index.
configuration
preamble detection
DB0_PWR_RAMPI
When it is setare
performance to LBFD-001001
NG_STEP
SC0, the subframemeans NO NO No
met. LBFD-002002
Indicates
that the
configuration
The value the local
power index
ID
is of
ramping the
0. When
DBM_120 cell.
step It set
it isis
indicates 0 YES YES No LBFD-001001
uniquely
dB,
to SC1,and
-120 dBm, the identifies
the
the value a
cell within
DB2_RAMPING_S
subframe
value DBM_118 a BS.
LBFD-001001
TEP means
configuration
indicates -118 that
index
dBm,the NO NO No
LBFD-002003
power
is
and1. other
Theramping
rest
values may step
is 2deduced
be
use dB.
the sameby
For details, see
analogy.
mapping.
3GPP
For the TS 36.321.
relation
details, see
between
3GPP TSsubframe 36.321.
configuration index
and cell subframe
cycle/offset, see
Scheduling
Indicates the type
Request
of PHICH(SR) duration. of the
PUCCH.
If PhichDuration is
BOOLEAN_FALSE
set to NORMAL,
means
the number that of
Indicates
simultaneous the
OFDM symbols
default
transmission pagingis not
occupied by the
period
allowed. forInthe this cell. It LBFD-001001
PDCCH can be NO NO No
is also
case, called
the UE the LBFD-002003
adaptively
Indicates theadjusted.
local
discontinuous
discards Sounding
If
ID PhichDuration
of the cell. It is
reception
RS and
Indicates onlya(DRX) YES YES No None
set to
uniquely EXTENDED,
period.
transmits
coefficient If identifies
the used EPC to a
the
cell number
within a of
BS.
specifies
ACK/NACK
calculate a DRX
theor SR.
OFDM symbols LBFD-002003
period
BOOLEAN_TRUE
resources for aused UE, the NO NO No
occupied by the by LBFD-002009
UE
means
the compares
PHICH that for this
the
PDCCH is
period
simultaneous
cell. It with the
corresponds LBFD-002003
permanently 3. If NO NO No
value
transmission
to the of
Ngthis isis 1.4
parameter LBFD-002009
the bandwidth
Indicates the local
parameter
allowed,
in the and
protocol. and the uses
MHz,
ID of the cell.
the number It of
the
UE
For smaller
transmits
details one
on the as YES YES No None
OFDM
uniquely symbols
identifies
its
usageDRXofperiod.
ACK/NACK the orNg SRIf a
occupied
Indicates
cell withindoes by
the
asee the
BS.
the
in EPC
shortened
parameter, not
mode. LBFD-002001
PDCCH
number is paging
3 or 4.
specify
For
3GPP details,
TSaofDRX see
36.211. NO NO No LBFD-002009
For the
occasions mapping
period,
3GPP the36.211.
TS UE uses LBFD-002011
between theortype
(subframes times
the value of this LBFD-002009
and
of the duration,
paging) NO NO No
parameter, which is LBFD-002011
see 3GPP in
contained
Indicates TSalocal
delivered the in the
36.211.
paging
ID of thecycle. cell. It
system information, YES YES No None
For
as details,
uniquely
its DRX
Indicates the see a
identifies
period.
3GPP
cell within
For details,
number TS of36.304.
aPUSCH
BS.
see
LBFD-002003
3GPP TS 36.304.
sub-bands. NO NO No
Indicates theseeof LBFD-002009
A larger
For details, value
hopping
this parameter
3GPP mode
TS 36.211. of
may LBFD-002003
the
lead PUSCH.
to a longer NO NO No
Indicates thesee LBFD-002009
For
delay details,
in paging
hopping
3GPP TS offset
36.211. ofa
UE but help reduce LBFD-002003
the PUSCH.
Indicates whether NO NO No
the LBFD-002009
For power
group details,
hopping seeof
consumption
3GPP TS 36.211. of the
the
UE. PUSCH is LBFD-002003
NO NO No
enabled.
Indicates the group LBFD-002009
For details, see
assignment of the
3GPP TS 36.211. LBFD-002003
PUSCH.
Indicates whether NO NO No
LBFD-002009
For details,hopping
sequence see
3GPP
of the PUSCHTS 36.211. is LBFD-002003
NO NO No
enabled. LBFD-002009
Indicates
For details, thesee cyclic
shift of the
3GPP TS 36.211. PUSCH. LBFD-002003
NO NO No
For details,
Indicates see LBFD-002009
Indicates whether the cyclic
3GPP
64QAM TS of 36.211.
the
shift interval of the
PUSCH
PUCCH.isThe enabled.
cyclic NO NO No LOFD-001006
For
shift details,
Indicatesinterval thesee oflocal
the
3GPP
ID of the
Indicates
PUCCH TScan 36.211.
cell.
the It
mobile
be
Indicates thethe cell YES YES No LBFD-001001
uniquely
country
acquiredcode identifies
on of thea
global
cell within
external
basis of the ID of a the
BS.
Indicates
external
CDMA2000 thecell mobile that LBFD-001001
average delay NO NO No
network
CDMA2000 code of the LBFD-002003
is shared
spread the cell,It
of among cell.
external
uniquely
multiple identifies a
which is operators.
acquired LOFD-001036
CDMA2000
A ID iscell that YES YES No
onPLMN
the basis of the LOFD-001037
is shared
around
comprised the among
globe.
of an
environment during
multiple
For
MCC andoperators.
details, ansee MNC. the LOFD-001036
networking. For YES YES No
A PLMN
CellGlobalIdCDMA2
The MCC IDconsists
is LOFD-001037
details, see 3GPP
comprised
000
of IE defined
three digits.of anin
TS 36.211.
Indicates the cell
MCC
3GPP and
36.331
The MNC consists an MNC.
6.3.4. LOFD-001036
global ID of the YES YES No
The MCC
Indicates
of two to three consists
the cell ID LOFD-001037
neighboring
of
of three
the local digits. cell. It
digits.
CDMA2000
The
uniquelyMNC HRPDa
consists
identifies YES YES No None
For example, if the
cell.
of
celltwo It uniquely
withinto three
an
MCC is 123 and the
identifies
digits.
eNodeB. a
MNC is 45, then the
CDMA2000
For example, HRPDif the YES YES No LOFD-001021
PLMN ID is 12345.
cell
MCCaround is 123the and the
globe.
MNC isFor 45,details,
then the
see
PLMN theID is 12345.
CellGlobalIdCDMA2
000 IE defined in
3GPP 36.331 6.3.4.
Indicates the
priority of the
neighboring cell
during blind
handovers. Blind
Indicates
handover whether is a
handovers
process in which of UEs
LOFD-001021
to
the the
eNodeBassociated NO NO No
Indicates whether LOFD-002002
neighboring
instructs aorUE cell toare
to permit
prohibited. prohibit
hand over LOFD-002001
removal of tothea NO NO No
specified LOFD-002002
neighboring relation
neighboring
by ANR. cell
without NO NO No LBFD-002018
Indicates
measurements. whether
this neighboring
There are 32 cell
LOFD-002001
is automatically
priorities altogether. NO NO No
LOFD-002002
discovered
The priority by hasthe a
ANR algorithm. LOFD-001021
Indicates the name
positive correlation NO NO No LOFD-002001
of
withthethe local
value cell.of
LOFD-002002
this parameter.
Indicates the name LOFD-001021
Note
of thethat
Indicates the value
neighboring
the NO NO No LOFD-002001
Indicates
0 indicatesthe
cell. that cell ID LOFD-002002
neighboring
of thehandovers
local cell. Itto
blind
CDMA2000 band a
uniquely
the neighboring identifies cell YES YES No None
class.
Indicates
cell Signals
withinthe
Indicates an on a
the
are prohibited.
frequency
eNodeB. within the
neighboring
frequency-specific LOFD-001021
band
offset class
CDMA2000 for thecan be YES YES No LBFD-00201803
obtained
frequencyby
CDMA2000 ofUEs.the LOFD-002002
For LOFD-001021
serving cell.Asee
details,
frequency. For
larger the
BandclassCDMA20 YES YES No LBFD-00201803
details,ofsee
value thisthe IE
00 IE in 3GPP LOFD-002002
CDMA2000-
Indicates
parameter
Indicates the
leads
whether sizetoof
36.331
CarrierInfo 6.3.4. LOFD-001021
the
to CDMA2000
a higher sizethe
set theprobabilityin of NO NO No
LOFD-002002
3GPP
search
of 36.331
triggering
Indicates
the CDMA2000 window.
the mobile 6.3.4
protocol.
UEs
country
search search
measurement codefor
window. of If the LBFD-001001
pilots
Indicates
reports.
external for Forthe
cell. details, NO NO No
this parameter is LOFD-001021
Indicates
neighboring
eNodeB
see
A PLMN the Q-
IDtheismobile
identity of
set to NOT_CFG,
network
CDMA2000
the external code
OffsetRangeInterRA
comprised ofcells
E- anof the LBFD-001001
the default
Indicates thesize cell (8) NO YES No
external
within
UTRAN
T
MCCIE the
defined
and cell.
time
cell.
an ItMNC.
in LOFD-001021
is used.
identity of the
A PLMN
period
uniquely
3GPP
The MCC ID
specified is
identifies
36.331 consists by
6.3.4.
external
comprised
thisthree
an parameter.
eNodeB E-UTRAN
ofwithin
anFora LOFD-001036
of digits. YES YES No
cell.
MCC
details,
PLMN. Itand
uniquely
see
The an theMNC.
28-bit LOFD-001037
The MNC consists
identifies
The
E-UTRAN MCC
MeasObjectCDMA2 aconsists
cell
cell
of two to three
Indicates the mobile LOFD-001036
within
of
000 IEan
three eNodeB.
digits.
defined YES YES No
identity
digits.
country 28-bit
is
code E- ofinthe LOFD-001037
The
3GPP MNC
comprised
For TS
example, consists
36.331.
of the
if the
external
UTRAN E-UTRAN
cell identity
of
celltwo
Indicates
MCC isto123
identity three
the and
andmobilethe
the LOFD-001036
cell
is that is shared
comprised ofofthe YES YES No
digits.
eNodeB
network
MNC is identity
code
45, then the
the LOFD-001037
among
cell multiple
identity
For example,
(represented
external
PLMN IDE-UTRAN
is 12345. if the
by the
operators.
(represented by 20 the LOFD-001036
MCCthat
most
cell is 123
significant
is and
shared the YES YES No
A PLMN
least ID is
significant LOFD-001037
MNC
bits).
among is
The 45, then
cell
multiple global the
comprised
eight bits) of an
PLMN
identity
operators. ID isand
(CGI) ofthe
12345. an
MCC
eNodeB and an
identity. MNC. LOFD-001036
E-UTRAN
A PLMN cell
is is
IDconsists YES YES No
The
The MCC
cell global LOFD-001037
comprised
of three (CGI) of an
digits. the E-
identity
UTRAN
MCC and cellan of an
identity
MNC. LOFD-001036
The
E-UTRAN MNC consists cell is YES YES No
and
The
of two the
MCC toPLMN consists
three ID. LOFD-001037
Indicates
comprised
For details, theof
see mobile
the
ID ofE-
of three
digits. digits.
country
UTRAN
the
3GPP cell. TS code
cell
It uniquely
36.413. of the
identity LOFD-001036
The example,
For MNC consists if ID.
the YES YES No
external
and thetoPLMN
identifies cell.
a GERAN LOFD-001037
of
MCC two
Indicates is 123three
the andmobile the
A
ForPLMN
cell withinID
details,
Indicates a is
the see
PLMN.
LAC
digits.
network
MNC
Indicates is code
45, the then of
mobile the
the LOFD-001036
comprised
3GPP
of the external of an
TS 36.413. YES YES No
For
PLMN example,
external cell.
IDcodeis if the
country
MCC
GERAN and an12345.
cell.
of
MNC. the LOFD-001037
MCC
A PLMN
external is 123
ID isand the
The MCCGERAN consists
MNC
comprised
cellthree is 45,
that digits. then
of
is shared an the LOFD-001036
of YES YES No
PLMN
MCC
among ID
and is
an
multiple 12345.
MNC. LOFD-001037
The MNC consists
The MCC
operators.
of two to three consists
LOFD-001036
of
A three digits.
PLMN
digits. ID is YES YES No
LOFD-001037
The MNC consists
comprised
For example, of an if the
of
MCC twoand isto123three
anand MNC. the LOFD-001036
digits. YES YES No
The
MNCMCC is 45,consists
then the LOFD-001037
For
of
PLMN example,
three IDdigits.
is 12345. if the
MCCMNC
The is 123 and the
consists
MNC
of twoisto45, threethen the
PLMN
digits. ID is 12345.
For example, if the
MCC is 123 and the
MNC is 45, then the
network code of the
external GERAN
cell that is shared
among multiple
operators.
A PLMN ID
Indicates theismobile
comprised
country code of an of the
MCC and
external UTRAN an MNC. LOFD-001036
YES YES No
The MCCthe
Indicates
cell. consists
mobile LOFD-001037
Indicates
of three digits.
network the of the
code
A PLMN
UTRAN
Indicates ID
cell
the isID.
mobileIt LOFD-001036
The MNC
external
comprised consists
UTRAN
of an YES YES No
uniquely
country
of twoand
cell. identifies
code
to three of thea LOFD-001037
MCC
cell in
external a an MNC.
PLMN.
UTRAN
digits.
A
ThePLMNMCC
Indicates IDconsists
ismobile LOFD-001036
cell
For that
example,
comprised isthe
shared ifofthe YES YES No
of threemultiple
network
among code an
of
digits. the LOFD-001037
MCC
The is 123
and
MNC
external an and
MNC.
consists
UTRAN the
Indicates
operators.
MNC is 45,the thencell the
The
of two
cell MCC
thatto consists
three LOFD-001036
global
A PLMN
PLMN IDis of
ID shared
is is the YES YES No
of threeID
digits.
among digits.
multiple 12345. LOFD-001037
external
comprised of an
The
For MNC consists
example,
operators. if the
CDMA2000
MCC and an cell.
MNC. It LOFD-001036
of
MCC
A twoisto123
PLMN three
ID isand the YES YES No
uniquely
The MCC consists a
identifies LOFD-001037
digits.
MNC
comprisedis 45, ofthenan the
CDMA2000
of three digits. cell
For
PLMN
MCC example,
andID is
an if the
12345.
MNC. LOFD-001036
around
The MNC theconsists
globe. YES YES No
MCC
The is
MCC 123 and
consists the LOFD-001037
For
of twodetails,
to45,three see the
MNC
of is
three digits. then the
CellGlobalIdCDMA2
digits.
PLMN
Indicates
The MNC ID theisconsists
12345.
band
000 IE
For example, defined if in
the YES YES No LOFD-001021
class
of two
3GPP on to which
three the
MCC is36.331 123 and 6.3.4.the
external
digits.
The global ID of a LOFD-001021
MNC
Indicatesis 45, then
thecell the
CDMA2000
For example,
CDMA2000 HRPDif the NO YES No LBFD-00201803
PLMN
frequency ID ison12345. which
operates.
Indicates
MCC
cell is 123
consists Forand
the type
of 16the LOFD-002002
the
of external
details,
the see 3GPP LOFD-001021
MNC
decimal
Indicatesisexternal
45,
digits,
the then and the
CDMA2000
TS 36.331.
CDMA2000 cell
cell. By NO YES No LBFD-00201803
PLMN
that of
scrambling ID
a is code,
12345.
operates.
Indicates
default, the For
the cellmobile LOFD-002002
CDMA2000
which
details,
country isseeused
code 1xRTT
3GPP
of asis
the
a LBFD-001001
CDMA2000
cell
the consists
physical HRPD
of 6
TS 36.331.
external
cell. cell.cell NO YES No LOFD-001021
decimal
identifier
Indicates
A PLMN digits.
of
the
ID the
is mobile LBFD-00201803
Note
external
network thatcode the cell of the
comprised of an LOFD-001021
global
CDMA2000
external IDcell.
of acell. NO NO No
MCC and an1xRTT MNC. LBFD-00201803
CDMA2000
A PLMN IDconsists
is
The
cell MCC
consistsofofan6
comprised LOFD-001036
of three digits.
decimal NO YES No
MCCMNC
The anddigits,an MNC. and LOFD-001037
that
The of
MCC a consists
consists
of two to three
CDMA2000 HRPD LOFD-001036
of three digits.
digits. NO YES No
cell consists of 16 LOFD-001037
The
For MNC consists
example, if the
decimal
Indicates
of twoisto123 digits.
the
three name LOFD-001021
MCC
of the external and the NO NO No LBFD-00201803
digits.
Indicates
MNC
Indicatesis 45, the
thethen cell
cellthe ID
CDMA2000
For
globalexample,
ID cell.
if the LOFD-002002
Indicates
PLMN
of the ID of
local the the
is cell.
12345. It
MCC
priority
uniquely isof
neighboring 123 theandcell. the
identifies It a YES YES No None
MNC
uniquely is
neighboring
cell within an 45, then
identifies
cell thea
PLMN
CDMA2000
during
eNodeB. ID
blind is 12345.
1xRTT
cell around the
handovers. Blind YES YES No LOFD-001021
Indicates
globe.
handover Forwhether
isdetails,
a
handovers
see the in which
process of UEs
LOFD-001021
to the associated
CellGlobalIdCDMA2
the eNodeB NO NO No
Indicates whether LOFD-002002
neighboring
000 IE defined
instructs aorUE cell inare
to
to permit
prohibited. prohibit
3GPP 36.331 LOFD-002001
hand
removal over of tothea6.3.4. NO NO No
specified LOFD-002002
neighboring relation
neighboring
by ANR. cell
without NO NO No LBFD-002018
Indicates
measurements. whether
this neighboring
There are 32 cell
LOFD-002001
is automatically
priorities altogether. NO NO No
LOFD-002002
discovered
The priority by hasthe a
ANR algorithm.
Indicates the name
positive correlation LOFD-001021
NO NO No
of thethe
with localvalue cell.of LOFD-002002
this parameter.
Indicates the name
LOFD-001021
Note
of thethat the value
neighboring NO NO No
Indicates LOFD-002002
0 indicatesthe
cell. that cell ID
of
blind handovers Itto
the local cell.
uniquely
the neighboring identifies cella YES YES No None
cell within
are prohibited. an
eNodeB.
reselectionused
threshold to in
neighboringtocells on
reselection
a higher-priority
neighboring cells on
Indicates
Indicates
neighboring the
the
a lower-priority
neighboring
absolute
CDMA2000 priority of
CDMA2000
CDMA2000
frequency. band
the CDMA2000
frequency.
class.
band Signals
class
UEs always on a
toperform
be
After starting
frequency
used during
measurements within
cell the LOFD-001021
measurements for for
band class
reselection. can be YES YES No LBFD-00201803
neighboring The
higher-priority cells on
obtained
value by UEs.
0 indicates
neighboring cells. A LOFD-002002
a lower-priority
For
the details,priority.
lowest
UE considers see a the LOFD-001021
frequency in the NO NO No
BandclassCDMA20
Cells of different
neighboring band cell on LBFD-00201803
CDMA2000
00
RATs IE cannot
in 3GPP
Indicates
a the the
higher-priority
class, UEhave mobile
36.331.
the same
country
considers oneof the
frequency code in the NO NO No LBFD-00201803
reselection
external
CDMA2000
neighboring cell.priority.
bandas
Indicates thecell
information mobile
The
class
a PLMN
as a consists
candidate
network code forof is the
contained
of the MCCin SIB8. NO NO No LBFD-00201803
candidate
reselection
external cell. ifand
for thethe
For
MNC. details,level
reselection
RX signal ifseetheof
The
3GPP
The PLMN
MCC TS consists
36.331.
consists
RX
the signal
serving level
cell of isthe YES YES No LOFD-001020
of the
Indicates
of MCC theand cellcell ID
thethree
less than digits.
neighboringa
MNC.
of
The theMNCneighboring
consists
is greater threshold
specified than the
The
GERAN
of twoMCC to consists
cell.
three It
value
during ofa this
specified YES YES No LOFD-001020
of three
uniquely digits.
identifies
digits.
parameter
cell reselection during aa
The
GERAN
For MNCcell
example, consists
within
MCC
specified
time, that cell
of the
of
the
= two
area
123,
Indicates to
MNC three
specified
the =LAC 45, YES YES No LOFD-001020
reselection
Indicates
neighboring time
whethercell is
digits.
by
PLMN
of the
the location
=than
12345.
neighboring area
and
to set
greaterother
the related
routing the
For example,
identity (LAI). MCC
GERAN
conditions
area
value code
ofMNCcell.
this areItAn
(RAC) met. for YES YES No LOFD-001020
=
LAI123,
consists
uniquely =
of45,
identifies the a
For
the details,
external
parameter
Indicates see
during
theand
PLMN
MCC,
location = within
MNC, 12345. a
3GPP
the cellTS
GERAN
GERAN 36.304
cell.
reselection
band This
LAC.
PLMN.
5.2.4.5.
parameter is NO NO No LOFD-001020
time, and
indicator. If theother
required
related
GERANconditionsif the is
ARFCN
external
are met.
Indicates
a value inthe GERAN
Forthedetails,
range
cell
see supports
3GPP packet
TScode. NO YES No LOFD-001020
routing
Indicates area
of 512 to 810, the the
switched
36.304of5.2.4.5.
network
value (PS) code
color
this
services.
(NCC)
parameter of GERAN.
is used It NO YES No LOFD-001020
Indicates
is indicatethe
to operator-specificwhether
GERAN
and BCCHa
identifies
the GERAN
Indicates
ARFCN.
network the details,
For
within base NO YES No LOFD-001020
frequency is in the the
station
see 3GPP
Indicates
whole color TS
whether
country. code
1800MHz band or
(BCC)
45.005.
the ofsupports
the
the cell
The base
1900MHz band. NO YES No LOFD-001020
external
the dual
transceiver GERAN
For details, station see
cell. Thecode
transmission
identity basemode. (BSIC)
3GPP TS 36.331.
transceiver
If the cellofsupports
consists station
the NCC NO YES No LOFD-001020
identity
the
anddualthe code
base (BSIC)
consists
transmission
station color of the BCC
mode,
code
and the network LOFD-001020
both CS and
(BCC). For details, PS NO NO No
color code (NCC). LOFD-001046
services
Indicates
see 3GPP can
theTS be
mobile
Indicates
For
handeddetails,
country the
oversee name
to
of the
23.003. code the
of
3GPPthe
cell. external
TS
Otherwise,
neighboring 23.003. only NO NO No LOFD-001020
Indicates
GERAN
Indicates the
the cell
cell. mobile ID
the
GERAN
of CSlocal
the service
cell. cell. orIt
network
the
The PS
PLMN code
service of
consists the
cana
uniquely
neighboring identifies YES YES No None
be
of
cell handed
the MCC
withincell. anover
and to
the
GERAN
the
MNC. cell.
eNodeB.
The
The PLMN
MCC consists consists YES YES No LOFD-001020
of
of the
three MCC digits. and the
MNC.
The MNC consists
The MCC
Indicates
of two
Indicates consists
the
to three
the LACID
cell YES YES No LOFD-001020
of
of three
the
digits.
of digits.
neighboring
the neighboring
The
GERAN MNCcell.
For example,
GERAN consists
cell. It
ItMCC
of two to three YES YES No LOFD-001020
uniquely
= 123,
uniquely MNCidentifies
= 45, a
identifies a
digits.
location
PLMN = within
GERAN 12345.
cell withina
For
PLMN.
the example,
area specified MCC YES YES No LOFD-001020
=
by the location 45,
123,
Indicates MNC whether= area
PLMN
to permit
identity =(LAI).
12345.
or prohibitAn LOFD-002001
removal
LAI consists of the of the NO NO No
LOFD-002002
neighboring
Indicates
MCC, MNC, whetherrelation
and
by ANR. of UEs
handovers
LAC. NO NO No LOFD-002002
to the neighboring
cell are prohibited.
during blind
handovers. Blind
handover is a
process in which
Indicates
the eNodeB the
reselection
instructs a UE priorityto
of the frequencies
hand over to a
in the GERAN
specified
carrier
neighboring frequency cell. NO NO No LBFD-002018
Indicates
group.
There are It iswhether
32
this neighboring
contained
priorities in system
altogether. cell
LOFD-002001
is automatically
information
The priority has a block NO NO No
LOFD-002002
discovered
type
positive7 (SIB7). by The
correlation the
ANR
UE
Indicatesalgorithm.
withdecides
the value the name of
whether to reselect NO NO No LOFD-001020
of
thisthe local
parameter. cell.
to
Notea neighboring
Indicatesthat a the GERANvalue
name
cell
of on
carrier
0 indicates a frequency
frequency
the neighboring that NO NO No LOFD-001020
Indicates
in thehandovers
group.
blind
cell. GERAN the cell
In the celltoID
of
thethe
carrier local
reselection frequency
neighboring cell. It cell
uniquely
group
are notbased
procedure, identifies
allowed. the on thea YES YES No None
cell within
value
GERAN of this an
carrier
eNodeB. and
parameter
frequencies arethe LOFD-001020
absolute priority of YES YES No
organized
Indicates thein groups LOFD-002002
Indicates
the the
andserving
the cell
standard that cell. is
GERAN
If the value band of this
reselection
supported by NO YES No LOFD-001020
Indicates If
indicator.
parameter
the
isthethe
parameters
current
Indicates
starting carrier
whether
ARFCN are in
GERAN
greater ARFCN
than the is
provided
frequency
to
the set the
GERAN pergroup. group
carrier LOFD-001020
a value
absolute in the
priority range of NO YES No
of GERAN
reselection
frequency carrier
priority
group. LBFD-00201803
of
the512 to 810,
serving cell, the the
frequencies.
of the frequencies
For details, see
value
UE of thisperforms
always
in
3GPPthe
parameter GERAN
TS 36.331.is used NO YES No LOFD-001020
measurements
carrier frequency on
Indicates
to indicate the whether
neighboring
Indicates
group.
Indicates whether
the
If the
the cells
RX on
value
RX
minimum
the GERAN required
the
to
signal
of GERAN
set
this the
level maximum
parameter carrier
signal
RX level
signal
frequency
frequency
level
is
group; in theis NO NO No LBFD-00201803
transmit
threshold
not
used power
specified,
thresholdin the used
used the that
in
in
1800MHz
Indicates
then if the band
whether
RX or
the
UE UE
reselection
does
reselection
evaluation cannot apply
to
to
for cell to
the
to 1900MHz
set the
signal level maximum
of band.
oneon NO NO No LBFD-00201803
uplink
neighboring
reselect
neighboring
selection. transmission
to During cells
cells on
For details,
transmit
neighboring power seecell that
on
a aevaluation
frequency
higher-priority
neighboring
a
thelower-priority cellsforin on
3GPP
the
meets UE TScan
the 36.331.
apply
related to
the
GERAN
GERAN
cell GERAN
selectionfrequency.
frequencies
frequency. carrier
and in
uplink
conditions,transmission
the NO NO No LBFD-00201803
frequency
UEs
the
After always
GERAN
starting
reselection group. a in It
toperform
carrier
on a frequency
neighboring
is used
measurements in cellfor
criteria S
frequency
measurements
neighboring
the GERAN
group.cellfor
carrier on
becomes
to calculate
higher-priority
neighboring a the NO YES No LBFD-00201803
a frequency
frequency group.in theon
cells
candidate
compensated
neighboring
a lower-priority
GERAN
for
carrier cells.ItA
is used
reselection.
power.
UE in criteria
For
considers If the S
details,
a
frequency in the
group,
to
see calculate
value of this
3GPP
neighboring TS the
cell on NO NO No LBFD-00201803
GERAN
the UE carrier
calculates
compensated
parameter
36.104.
a higher-priority is less
frequency
the Srxlev
Indicates thegroup,
value for
power.
than theFor
frequency details,
absolute
in the cell
the UE considers
neighboring
frequency specific NO NO No LBFD-00201803
see 3GPP
priority
GERAN TS
ofcarrier
the
one
based
offset neighboring
ofonthe thegroup
36.104.
serving
frequency cell, the UE
cellneighboring formula:as
as a candidate
following
of group
starts
a
for the
candidate
reselection for if the NO NO No LBFD-00201803
Srxlev
GERAN = carrier
Measured
measurements
reselection
RX signal ifofThis
the only
RSSI valuelevel
frequencies. the of
when
RX
the the
signal
serving RX
level
cell signalof
is- a
neighboring
parameter
Indicates whether cell
isserving
used LOFD-001020
level
the
less of the
neighboring
than a cell NO NO No
Minimum
in
BCCHthe decisionRX
carrier signal
withof LOFD-002002
cell
is is low;
greater
specified then
than
threshold if
the
level
the UE- Power
the
the
value
duringRXofato
specific send
signal
this
specified
NCC level is
compensation.
measurement
permitted for For NO NO No LBFD-00201803
of
cellone
parameter neighboring
reselection
Indicates the during cell ID a
details,
reports
monitoring. see
for 3GPP
inter-
For
cell
of meets
specified
time,
the that
local ofthe
cell the
cell. It
TS 36.304.
RAT
details,handovers.
see 3GPP For
related
reselection
neighboring
uniquely conditions,
time
identifiescell is a YES YES No None
details,
Indicates
TS
the 36.331.see
neighboringthe 3GPP
index cell
and
greater
cell
TS
of other
within
36.331.
the than
BCCH related
anthe carrier
becomes
conditions
value of this
eNodeB. a are met.
frequency
candidate group. It
for LBFD-002009
For details,
parameter see
during YES YES No
identifies
Indicates
reselection. a
the BCCH
Cells of LOFD-001020
3GPP
the cell
carrier TS 36.104.
reselection
frequency
GERAN
different BCCH
RATs
time,
group. andFor other LBFD-002009
ARFCN.
cannot have details,
the YES YES No
related
Indicates conditions
the LOFD-001020
see
same 3GPP
reselectionTScell ID
are
of met.
the
45.005. localForcell. details, It
priority.
Indicates
see 3GPP For the TS details,
uniquely identifies a YES YES No None
see 3GPP TS
physical
cell withincell
36.104. an
36.331. of the
identifier
eNodeB. LBFD-00201803
intra-frequency YES YES No
LBFD-00201801
blacklisted cell. For
details, see 3GPP
TS 36.211.
EARFCN
Band 6: UL range:
2750
EARFCN to 3449, range:
lowest
20650 to frequency
20749, of
the DL frequency
Indicates
lowest operating
the mobile of
band:
country
the 2620;
UL operating
code of the
Band
Indicates
E-UTRAN
band: 8:
830; DL the
Indicates
EARFCN
Indicates the
range:
the cell
mobile ID
eNodeB
neighboring
Band 7: identity
UL cell. of
of
3450theto
network local
3799,
code cell. of Itthe
the
The
EARFCNintra-frequency
PLMN
Indicates range:
the consists
cell a
uniquely
lowest identifies
frequency YES YES No None
E-UTRAN
neighboring
of
20750
the
identity MCC
toof 21449,
the cell.
and the
intra- Itof
cell
the within
DL
neighboring operatingancell.
uniquely
MNC.
lowest
frequency identifies
frequency of
eNodeB.
band:
The PLMN925; consists
an
TheeNodeB
the ULMCC
neighboring operating within
cell. Ita
consists YES YES No LBFD-00201801
Band
of the
PLMN.
of
band:
three 9:
MCC DL
The
2500;digits.
uniquely identifies and
28-bit thea
EARFCN
MNC.
E-UTRAN
The within
Band
cell MNC8: UL range:
cell
consists
an
3800
The
identity
of two
EARFCN
eNodeB. totois
MCC 4149, consists
three
range:
The 28-bit YES YES No LBFD-00201801
lowest
of three
Indicates
comprised frequency
digits. to 21799,
21450
E-UTRAN digits.
the the of
of cell-
cell
the
For DL
The
specific
cell MNC
Indicates
lowest operating
identity
example,
identity offsetconsists
the
frequency
is and forthe
cell
MCC of
band:
of
the two 1844.9;
to three
intra-frequency YES YES No LBFD-00201801
eNodeB
specific
=
the123,
UL MNC identity
offset
operating
comprised of the = 45,
Band
digits.
neighboring
between
PLMN
band:
cell 10:
(represented880; DLcell.
the
= 12345.
identity by the It
EARFCN
For
affects
serving
Band example,
the
most significant
9: cell
(represented range:
UL and MCC
by 20the YES YES No LBFD-00201801
4150
= toMNC
probability
bits). The
intra-frequency
EARFCN
least 4749,
123,significant of=global
cell
range: 45,
lowest
PLMN
triggering
identity
neighboring
21800
eight bits) =frequency
to 12345.
(CGI) intra-
22149,
and cellofthe
an of
the DL operating LBFD-00201801
frequency
E-UTRAN
that
lowest is related
eNodeB identity. of
frequencycell is
to NO NO No
band: 2110; LOFD-002009
measurement
comprised
triggering
the
The ULcell ofofcell
operating
global the E-
Indicates
Band
reports. 11: A the
DLlarger
UTRAN
reselection.
band:
identity cell
1749.9;
(CGI) identity
The of an
reselection
EARFCN
value of this priority
range: NO NO No LBFD-00201803
and
larger
Band
E-UTRAN the the
10: PLMNULvalue
cell ID.
is of
of
4750theto
Indicates
parameter neighboring
whether
4949, indicates
For
this
EARFCN details,
parameter
comprised see
range:
of theis, E-
E-UTRAN
handovers
lowest
a higher frequency of UEsof
probability. LBFD-00201801
3GPP
the
22150
UTRAN less TS
to 36.413.
possibly
22749,
cell identity NO NO No
frequency.
to
the
For the
DL neighboring
operating
details,
Indicates It is
seeID.of
whether LOFD-002001
the
lowest
and cell reselection
thefrequency
PLMN
contained
cell
band:
3GPP
to are
permit 1475.9;
TS inprohibit
prohibited.
36.331.
or system
occurs.
the
For UL Thissee
operating
details,
information
Band
removal 12: ofDL block
the NO NO No LOFD-002001
parameter
band: is
3GPP
type
Indicates
EARFCN 5 1710;
neighboring
TS
(SIB5). 36.413.
whether
range:
contained
Band
The
this UE DLrelation
11:decides
neighboring
in SIB4.
cell
5000
by
ForANR.
EARFCN to 5179,
details, see
range:
whether
is automatically
lowest to reselect
frequency NO NO No LOFD-002001
3GPP TS
22750 36.331.of
to 22949,
to aDL neighboring
discovered
the operating by the
lowest
cell
ANR on frequency
the
algorithm. of
Indicates
band:
the DL 728; the name
operating LBFD-00201801
neighboring E- NO NO No
of
Bandthe 13:
band: local
1427.9; DLcell. LOFD-002001
UTRAN
EARFCN
Indicates frequency
range:
the name
Band
based 12:
on5279,DL
the value LBFD-00201801
5180
of theto
EARFCN neighboring
range: NO NO No
of this parameter
Indicates
lowest the cell ID
frequency LOFD-002001
cell.
23000
and the to 23179, of
absolute
of
the the
DL local
operating cell. It
lowest
Indicates
priority frequency
of whether
the of
uniquely
band: 746; identifies a YES YES No None
the
to DL operating
cellset
serving
Band the
within
14: cell.UL
DL an
band:
EARFCN.
If the value698;Ifof thisthis
eNodeB.
EARFCN range: LBFD-00201803
Band
parameter 13: DL is set to YES YES No
5280
EARFCN to 5379, range: LBFD-00201802
NOT_CFG,
greater
lowest than
frequency the
the UL of
23170 to 23279, LBFD-001001
EARFCN
absolute
the DL
Indicates is the DL
priority
operating
whether of
lowest
Indicates frequency
the time of NO NO No LBFD-00201803
EARFCN
the
band:
to serving
set 758; plus cell, the
the
18000
UE DLthe
threshold
always operating
in for
FDD inter-
performs
LBFD-00201802
Band 17: LBFD-001001
reselection
band:
frequency
mode
measurements776;DL
and
priority
cell
is theon
EARFCN
of the range:
neighboring NO YES No LBFD-00201803
Band
same
neighboring14:
reselection.
as5849, DLAcells
the DL UE on
5730
E-UTRAN to LBFD-00201802
EARFCN
initiates
EARFCN
the neighboringa range:
inIfTDD E-
lowest
frequency.
23280
reselection frequency
to 23379,tothe the of
mode.
UTRAN frequency; NO NO No LBFD-00201803
the
value
lowestDL of operating
this
frequency
inter-frequency of
then
band:
parameterif 734;
the RX
iscellnot
the DL
neighboring
signal operating
quality
Indicates
Band
specified,
band:
only 18:
788;
after DLthe of
the
the UEone
signal NO NO No LBFD-00201803
Indicates
neighboring
scaling
EARFCN whether
factorrange: cell
does
Indicates
Band
quality not
17:intoreselect
the
DL
the cell isto
to set to
meets
applied
5850 the
the5999,speed-
related
neighboring
measurement
EARFCN
better thanrange: cells
that inon
dependent
conditions,
TReselEutra
Indicates
lowest the
frequency scaling
the for NO NO No LBFD-00201803
the
23730
the frequency.
bandwidth
servingto of
23849,cell theforof
parameters
neighboring
medium-mobility
scaling
the factor
DL frequency
operating related
cell
inter-frequency
lowest
a period defined byof
to cell
becomes
UEs.
applied
band: reselection.
The
860; aactual
to cell on cell
neighboring
the
this DL operating
parameter and,
If this 19:
candidate
reselectionparameter
TReselEutran
Band fortime forforis NO NO No LBFD-00201803
the
band:
in
set 704;DLafter
frequency.
addition,
to NOT_CFG,
reselection.
medium-mobility
The the
high-mobility
EARFCN
setting
Band 18:of DL range:
this UEs.
UE
UEsthecamps
speed-dependent
If value
within onof the
E- this
The
6000
EARFCN actual
parameter to cell
6149, cell
depends
range: NO YES No LBFD-00201803
serving
cell
UTRAN reselections
parameter is is for
equal lessforare
toof
reselection
lowest
on
23850the frequency
bandwidth
toabsolute
23999,time
longer
not
than
the the
productthan
supported 1s.
of byThis
high-mobility
the DL frequency
configuration
lowest operating UEs
of the of
parameter
default.
priority
TReselEutra of the is and
within
band:
cell.
the DLIn E-UTRAN
875;
E-UTRAN,
operating isa NO YES No LBFD-00201803
contained
serving
TReselEutranSfMe in
cell, the UE SIB5.
equal
Band
cell
band: to
20:
815;DLseeis
bandwidth
For
starts
dium. details,
the
This LBFD-001001
TReselEutran
EARFCN
also expressed
Band 19: range: in
3GPP
measurements
parameter TS DL 36.331.
is only NO YES No LBFD-00201803
multiplied
6150
units
EARFCN to
of 6449, by
resource
range:
when
contained the
TReselEutranSfHig
lowest RX
frequencyin SIB5.signal LBFD-00201802
blocks
24000 (RBs).
to 24149, Cellof
level
For
h.
the This
DL of
details,
bandwidths the
parameter
operating serving
see
1.4 is
lowest
cell
3GPP frequency
is 3low;
TS then
36.331. if of
contained
band:
MHz,
the DL 791;
MHz,
operatingin SIB5.
5
the
For
Band
MHz, RX
details,
21:
10 signal
DLsee
MHz, level
15
band:
of one 830;
neighboring
3GPP
EARFCN
MHz,
Band TS
and
20: 36.331.
range:
DL20 MHz
cell
6450 meets
correspondto 6599, theto 6
EARFCN
related range:
conditions,
lowest
RBs,
24150 15 frequency
RBs,
to 24449, 25 of
the neighboring cell
neighboring
neighboring cells
cells on on
the
a DL operating
Indicates
higher-priority the
a lower-priority
band: 925; E-
frequency-specific
neighboring
neighboring E-
Band
offset 9:
of
UTRAN frequency. DL
the
frequency.
UTRAN
EARFCN range:
neighboring
Indicates
UEs
After always
starting the E-
perform
3800
UTRAN
minimum
measurements to 4149,
frequency.
required for
measurements
lowest frequency forof
It
RX is contained
signal
higher-priority
neighboring level cellsin on
the
system
used DLinoperating
neighboring information
the cells. A LBFD-001001
the
band: lower-priority
1844.9;
block
evaluation
UE considers
neighboring type 5for (SIB5).
E- acell NO NO No LBFD-00201803
Band
It is used
selection.
neighboring 10: in DL
Duringthe
cell on LBFD-00201802
UTRAN
Indicates
EARFCN frequency,
the
range:
evaluation
the
the evaluation
higher-priority
UE for cell
for
configuration
4150
reselection
cell toconsiders
selection
neighboring
Indicates 4749, and
whether and
E- for NO NO No LBFD-00201803
one
information
lowest neighboring
frequency about
the
to
cell settriggering
reselection
UTRAN as thea frequency to and
maximum
candidate a of
the
the intra-frequency
DL
Indicates
stopping operating
oftheevent
neighboring
as areselection
transmit candidate
power cellifforon
for
neighboring
band:
maximum
A4. For 2110; cellthat
transmit
details,
the
of
see
NO NO No LBFD-00201803
the
RX neighboring
reselection
the UE
signal can levelif the
apply ofE- to
the
Band
power serving
Indicates
3GPP 11:
that
TS DL
the acell.
36.331. UE
event
UTRAN
RX
uplink
the signal
serving frequency,
level
transmission cell of
is
BitString00:
EARFCN
can
to apply
trigger range:
to uplink
inter-
the UE calculates
neighboring NO NO No LBFD-00201803
on the
Indicates
less
Indicates
4750 than
transmission
frequency to athaton cell
neighboring
whether
4949, the
the
is
E-UTRAN
all Srxlev
greater
neighboring
specified valuethe
than
threshold for
cells
certain
lowest
neighboring
handovers. neighboring
frequency IfE-the of
the
value neighboring
frequency.
on
during this ofaneighboring
this If the
specified cell
cells
the
UTRAN DL
neighboring have operatingthe
frequency. E- same NO NO No LBFD-00201803
based
parameter
value
E-UTRAN
cell on the
of subframe.
reselectionthis during a
MBSFN
band:
It is used
UTRAN 1475.9; inare
frequency criteria
following
specified
parameter
frequency
time, that formula:
cell is
of the not
BitString01:
Band
S
and to the 12:
calculate DL the
Srxlev
reselection
specified,
configured
neighboring =serving
Measured
the time
withcell at
is NO NO No LBFD-00201803
Indicates
EARFCN
compensated
frequency that
range:
are all
inthe the
RSRP
and
maximum
least
greater other
two value
than related
power
antenna of
the is
neighboring
5000
power.
same to If 5179,
the
frequency cells
value
neighboring
conditions
subject
ports.
value Set
of tothis are
the
this cell
UEmet.-
have
lowest
of
band,this the same
frequency
parameter
either event of
is LBFD-00201803
Minimum
For
parameterdetails,
capability. RX tosee
For
duringsignal
TRUE NO NO No
MBSFN
the
not DL subframe.
operating
specified, the LBFD-00201802
ifA3
allor
level
3GPP
details,
the -event
these
cell
BitString10:
Power
TSsee A4
36.331.
3GPP
inter-
reselection can
band:
maximum
be used
compensation.
TS 36.101.728; to power
trigger For is
frequency
time,
Indicates and otherall
that LBFD-00201803
Band
subject
an 13: to
inter-frequency
details, see DL
the 3GPP UE NO NO No
neighboring
related
neighboring conditions cells
cellsthat LBFD-00201802
EARFCN
capability.
handover.
TS 36.304. range:
For
Note
are
have configured
met. mutuallyFor with
details,
Indicates
5180
details,
the to
handover the
5279,
see blind-
3GPP
at
see least
different 3GPP two
MBSFN TS NO NO No LBFD-00201802
handover
lowest
TS 36.101.
performance
Indicates priority
frequency
the when
cell of
antenna
36.331.
subframes. ports. SetID
the
event
of the inter-frequency
DL A3 operating
is
local cell.toIt used is
this parameter
BitString11:
neighboring
band:
better
uniquely 746;
than cell. a
that
FALSE
Indicates if identifies
one
that of
the
YES YES No None
Blind
Band
when
cell handover
14:
event
within DLan A2 is a
is
these
serving inter-
TDD cells
procedure
EARFCN
used.
eNodeB. If the in
range: which
frequency
Indicates
have neighboringthe LBFD-00201803
the
5280 eNodeB
neighboring to 5379, E- is YES YES No
neighboring
physical
cells of cell
different cells LBFD-00201802
instructs
lowest frequency
Indicates
UTRAN athe UEmobile
frequency toUL- of
configured
identifier
DL of
configurations. with
the only
hand
the
country
and DL over
the operating
code to aof the
serving LBFD-00201803
one
For
Indicates antenna
inter-frequency
details, seeport. YES YES No
specified
band:
E-UTRAN
frequency
Indicates 758;the are
the in ID
cell LBFD-00201802
blacklisted
Indicates
3GPP
eNodeB
neighboring
Band 17: the
TSfrequency
identity
DL cell.
36.331. mobile
cell
cell. For
of
different
of the local cell. Itthe
details,
network
the
without
EARFCN
The
Indicates PLMN see
code
inter-frequency range:
the 3GPP of
consists
cell
bands, only
uniquely identifiesevent a YES YES No None
TS
E-UTRAN
of the
identity36.211.
neighboring
measurements.
5730 toMCCof5849,the cell.
and inter-theIt
A4
cell can
within be used
an to
neighboring
uniquely
There
lowest
MNC.
frequency
trigger are identifies
frequency
an 32
inter- cell.
blind- of
eNodeB.
The PLMN consists
an
The eNodeB
handover
the DL
neighboring
frequency MCC within
consistscell. Ita
priorities
operating YES YES No LBFD-00201802
of
PLMN.
in
band:
of the
total.
three
uniquely
handover. MCCThe
The
734; digits. and
28-bit
identifiespriority thea
MNC.
E-UTRAN
has
Band
The
cell aMNCpositive
18:
within DLcell
consists
an
The
identity
correlation
EARFCN
of two
eNodeB. MCC toisthreeconsists
The with
range: 28-bitthe YES YES No LBFD-00201802
of three
comprised
value
5850 to
digits.
E-UTRAN digits.
of 5999,
this of the
cell
The
Indicates
cell
Indicates
parameter.
lowest
For
identity MNC
identity
example, is the consists
the
frequency and
The cell-
cell
MCC the of
of two to three for YES YES No LBFD-00201802
eNodeB
specific
value
the
= 123, DL 0
comprised of the identity
offset
indicates
operating
MNC = 45,
digits.
the
between
that
band:
PLMN
cell neighboring
(represented
blind
860; the
= 12345.
identity handover by the
For
cell.
most
serving
to
Band the example,
Asignificant
(represented larger
19: cell DLand MCC
value
by 20
the YES YES No LBFD-00201802
=
of 123,
this
bits).
corresponding
EARFCN
least The
inter-frequency MNC
parameter
significant cell
range: = 45,
global
PLMN
results
identity
neighboring
6000 bits)
eight to=in 12345.
(CGI)aand
6149, higher
ofthe
cell an
is LBFD-00201802
probability
E-UTRAN
that
prohibited,
lowest
eNodeB is related
frequency of
cell
values
identity. is of
to NO NO No
LOFD-002009
reporting
comprised
triggering
17
theto
The DL inter-
32operating
cell are ofofcell
global the E-
frequency
UTRAN
reselection.
assigned
band: 875;
identity cell
(CGI) to The identity
intra-
of an
measurement NO NO No LBFD-00201803
and
Bandthe
larger
eNodeB
E-UTRAN the
20: PLMN value
inter-
DLcell is ID.of
Indicates
events.
For
this
frequency
EARFCN details,
parameter For whether
range: details,
see is,
comprised of the E-
handovers
see
3GPP
the 3GPP
less
neighboring
6150 toTS TSofcells
36.413.
possibly
6449, UEs LBFD-00201802
UTRAN cell identity NO NO No
to
the
and the
36.331.
Indicates
lowest cell
usedneighboring
whether
reselection
in theID.of LOFD-002001
thefrequency
PLMN
cell
to
thepermit
occurs. areoperating
evaluation
DL prohibited.
This orfor prohibit
For details, see
removal
parameter
frequency-priority-
band: 791;
3GPP of
TS 36.413. the
is NO NO No LOFD-002001
neighboring
contained
based
Band 21: handover,
DLin relation
SIB5.
by
For
and
EARFCNANR.
details,
valuesrange: 1seeto 16 LBFD-00201802
NO NO No
3GPP
are
6450 used
Indicates toTS in
6599,36.331.
whetherthe LBFD-00201803
evaluation
lowest
this frequency
neighboring for other of
cell
handover.
theautomatically
is DL operating If the NO NO No LOFD-002001
switch
band:
discovered for by the
1495.9;
frequency-priority-
Band
ANR algorithm.32: DL
based
EARFCN inter- range:
frequency
17950 to 17999, handover
is turned
lowest on and the
frequency of
switch
the DL for operating
frequency-priority-
band: 1990;
based
Band 33: inter- DL
4150
EARFCN to 4749, range:
lowest
21800 to frequency
22149, of
the
lowestDL frequency
operating of
band:
the UL2110; operating
Band
band: 11: 1749.9; DL
EARFCN
Band 10: UL range:
4750 to
Indicates the
EARFCN 4949,
range: mobile
lowest
country
22150
Indicates frequency
to code22749,
the name of the of LBFD-00201802
the DL
Indicates
external
lowest operating
the
E-UTRAN NO NO No
of the local cell. of
frequency LOFD-002001
Indicates
band:
eNodeB
cell.
the UL1475.9; the mobile
identity
operating of
Indicates
network the
code name
Band
the
The
band: 12:
external
PLMN
1710; DL E-of the
consists LBFD-00201802
of the neighboring
Indicates the NO NO No
external
EARFCN
UTRAN
of
Bandthe 11:
MCC E-UTRAN
range:
cell.
DL Itcellthe
and LOFD-002001
cell.
identity
cell.
5000 of
to 5179, the
uniquely
MNC.
EARFCN identifies
range:
external
The
lowest
an PLMN E-UTRAN
frequency consists
withinofa LBFD-00201801
TheeNodeB
22750 MCC to consists
22949, YES YES No
cell.
of
the the
PLMN. It
DL uniquely
MCC
operating
The and the
28-bit LBFD-00201802
of threefrequency
lowest digits. of
identifies
MNC.
band:
E-UTRAN 728; acell
cell
TheDL
the MNC consists
operating LBFD-00201801
within
The
Band MCC
identity anis eNodeB.
13: consists
DL YES YES No
of two
band: to three
1427.9; LBFD-00201802
The
of
EARFCN 28-bit
three
comprised E-
digits.
range:
of the
digits.
Band 12: DL
UTRAN
The
5180
cell MNC
to
identity cell
5279, identity
consists
and the LBFD-00201801
For example,
EARFCN range: MCC YES YES No
is
of comprised
two
lowest to three
frequency of the
eNodeB
= 123, to
23000 MNC identity
23179, = 45,of LBFD-00201802
cell identity
digits.
the DL
(representedoperating by the
PLMN
lowest = 12345.
frequency of
(represented
For
band:
most example,
Indicates 746;
significant
whether by
MCC the
20 LBFD-00201801
the DL operating YES YES No
least
=
Bandsetsignificant
123,
bits).
to MNC
14:
The
the cell=global
DL
UL 45, LBFD-00201802
band: 698;
eight
PLMN
EARFCN
identity
EARFCN. bits)
= and
12345.
range:
(CGI) If this ofthe
an
Band 13: DL LBFD-00201801
eNodeB
5280
parameterto
E-UTRANrange: identity.
5379,cell
is set is to NO YES No
EARFCN LBFD-00201802
The
lowest cellfrequency
comprised
NOT_CFG, globalofthe theUL of
E-
23170 to 23279,
identity
the
UTRAN
EARFCNDL (CGI)
operating
cell
is of DL
identity
the an LBFD-00201801
lowest frequency of NO NO No
E-UTRAN
band:
and
EARFCN the758; PLMN cell is
plus ID. LBFD-00201802
the DL operating
comprised
Band 17:
For details,
18000 in FDD DL ofsee the E-
band: 776;
UTRAN
EARFCN
3GPP
mode TScell
and is identity
range:
36.413.
the LBFD-00201801
Band
Indicates 14: DL
the NO YES No
and
5730
same the
to
as PLMN
5849,
the DLID. LBFD-00201802
EARFCNcell
physical range: ID of
For
lowest
EARFCNdetails, in see
frequency TDD of
23280
the to
external 23379,E- LBFD-00201801
3GPP
the
mode. DL TS 36.413.
operating NO YES No
lowest frequency
UTRAN cell. For of LBFD-00201802
band:
the DL734;
Indicates the3GPP
operating
details, see
Band
tracking 18: DL
TS 36.211. code
band: 788; area
NO YES No
LBFD-00201801
EARFCN
of
Bandthe 17:
externalrange:
DL E- LBFD-00201802
Indicates
5850 to the
5999, mobile
UTRAN
EARFCN
Indicates cell.
range:
the name
country
lowest code of the
frequency LBFD-00201801
23730
of to
the external
neighboring 23849,UTRAN E- of NO NO No
the DL
Indicates operating
the cell ID LBFD-00201802
lowest
UTRAN frequency
cell.
Indicates the mobile
cell. of
band:
of
the the
DL
network 860;
local
operating
code cell. of Itthe
The
Band PLMN
uniquely 19: DL consistsa
identifies YES YES No None
band:
of the 704;
neighboring
MCC UTRAN
EARFCN
cell
Band
cell. within
18: DLanand the
range:
MNC.
6000
eNodeB. to 6149,
EARFCN
The
The PLMN
MCC range:
consists
consists YES YES No LOFD-001019
lowest
23850
of three
the MCC frequency
to 23999,
and the of
of
the DL digits.
operating
lowest
MNC.
The MNC frequency
consistsof
band:
Indicates
the
The DL
MCC875; the
operating
consists YES YES No LOFD-001019
of
Bandtwo20:
priority to three
DL
ofdigits.
the
band:
of three
Indicates
digits. 815; the
EARFCN
neighboring
Band
The MNC19:cell range:
DL cell
consists
UTRAN
For example,
Indicates
6150 to ID.
whether
6449, MCC It
during
EARFCN
of two blind
to range:
three YES YES No LOFD-001019
uniquely
=
to 123, MNC identifies
allowfrequency
lowest handover = 45, a
handovers.
24000
digits. to Blind of
24149,
cell
PLMN
of
the within
UEs
DL = to a
12345.
the
operating PLMN.
handover
lowest is a MCC
frequency LOFD-001019
For example,
neighboring
band:
process 791; in cell of
which NO NO No
the
= DL
123,
Indicates operating
MNC whether= 45, LOFD-002002
that
Band
the is21:
determined
eNodeB DL
band:
PLMN
to
by permit830;
= 12345.
or
the neighboring prohibit
EARFCN
instructs range:
aDL UE LOFD-002001
Band
removal
relation. 20:of the to NO NO No
6450
hand to
over
EARFCN range: 6599,torelation
a LOFD-002002
neighboring
lowest
specified
24150 to 24449, of
frequency
by ANR.
the DL
neighboring operating
lowest frequency cell. of NO NO No LBFD-002018
Indicates
band: whether
the DL1495.9;
There are 32
operating
this
Band neighboring cell
band: 32:
priorities832; DL
altogether. LOFD-002001
is automatically
EARFCN
The priority range:
has a NO NO No
Band 21: DL LOFD-002002
discovered
17950
positive by the
tocorrelation
17999,
EARFCN range:
ANR
lowest
with algorithm.
Indicates
thetofrequency
the name
value of of
24450 24599, NO NO No LOFD-001019
the
of
thisthe
lowestDL local
operating
parameter.
frequency cell. of
band:
Note
Indicates
the DL 1990;
that the name
operating value
Band
0
of 33:
indicates DL
the neighboring
band: 1447.9; that NO NO No LOFD-001019
Indicates
EARFCN
blind the
range: celltoID
Band handovers
cell. 32: DL
of the
36000
the local
to 36199,
neighboring cell. It
EARFCN range:cell
uniquely
lowest identifies
frequency a YES YES No None
are
35950 notto 35999, of
allowed.
cell
the within
DL an
operating
lowest frequency of
eNodeB.
band:
the DL1900; operating
Band
band: 34: 1910; DL
EARFCN
Band 33: DL range:
36200
EARFCN to 36349,
range:
lowest
36000 to frequency
36199, of
the
lowestDL frequency
operating of
band: 2010;
Band 1: UARFCNs:
frequency.
Normal ULThe UE
Normal UARFCNs:
UARFCNwhether
decides
[4132-4233] = DL to
[2237-2563]
UARFCN
Indicates
reselect
Special to the
- a950;
UARFCNs: DL
Special UARFCNs:
Band
UARFCN
neighboring
(782, 2: UL of the
cell on
(2587,787, 2612, 807, 2637,
UARFCN
external
the
812, UTRAN UTRAN
= DL
2662,837, 2687, 862) 2712,
UARFCN
cell.
frequency
Band The UARFCN -based
400; on
2737, 6: 2762, 2787,
Band
range
the
Normal value3:
inUARFCNs:
UL
each
of this FDD
2812, 2837, 2862,
UARFCN
frequency
parameter =band DL is LBFD-002009
2887, 2912) the
[4162-4188]
Indicates the and UL
UARFCN
shown
absolute
Special as -follows:
475;
priority
of the of YES YES No LOFD-001019
Band 8: UARFCNs:
UARFCN
Indicates the
Band
the
(812,
external 4:
1:
serving
837) UL
UTRAN cell. LOFD-002002
Normal
working UARFCNs:
mode
UARFCN
Normal
If
Bandthe
cell. value
7: UARFCNs:
The UARFCN = DLthis
of LOFD-001019
[2937-3088]
supported by the NO NO No
UARFCN
[10562-10838]
parameter
Normal
range -
UARFCNs:
inUARFCNs:
each 2000;
is FDD LBFD-00201803
Special
UTRAN
Indicates in the the
Band
Special
greater
[2012-2338]
frequency 5: UARFCNs:
UL
than band the is
none
current
TDD/FDD UARFCN. mode of LOFD-001019
UARFCN
none
absolute
Special
shown =
priority
UARFCNs: DL of NO NO No
Band
the 9:as
inter-RAT
follows:
LOFD-002002
UARFCN
Band
the
(2362,
Band 2:
serving
1:2387, - 225;
cell,2412, the
Normal
UTRAN. UARFCNs:
Band
Normal
UE
2437,
Normal 6:
always
2462,UARFCNs:
ULperforms
UARFCNs: 2487,
[9237-9387] LOFD-001019
UARFCN
[9662-9938]
measurements
2512, = DL on NO NO No
Special2537,
[9612-9888] UARFCNs: 2562, LBFD-00201803
UARFCN
Special
neighboring
2587,
Indicates
Special 2612, UARFCNs:
- 225;
whether
UARFCNs: cells
2637, on
none LOFD-001019
(412,437,462,487,5
Band
the
2662,
to
none UTRAN
set 7:
the
2687) UL UL
The
IndicatesUARFCN whether NO YES No LBFD-00201803
12,537,562,587,612
UARFCN
frequency;
UARFCN.
Band 8:
2: =IfthenDL
the if
range
to set in each
the priority TDD of LOFD-002002
,637,662,687)
UARFCN
the
Normal
value RX of signal- 600;
UARFCNs:
this level
frequency
Indicates
a cell assigned the bandwith is
Band
of one3:
[2712-2863]
parameter
Indicates 8:neighboring
ULis not
[9262-9538]
shown
minimum
the UARFCN as theRXfollows: signal
used
NO NO No LBFD-00201803
Normal
UARFCN
cell
Special meets
specified,
maximum
minimum
Special UARFCNs:
= the
UARFCNs:
the DL
transmit
required
UARFCNs:
Band
quality
in cell 1: used
reselection in theto
[1162-1513]
UARFCN
related
none
default
power
RX
(12, 37,that
signal 62, -
conditions,
DL 225;
the
level87,cellUE 112,
Normal
evaluation
UTRAN. UARFCNs: for LBFD-00201803
Indicates
Special
Band
the
UARFCN
can
used
137, 9: the
neighboring
Indicatesapply
in
162, UL the
UARFCNs:
the
isto
187, RX
RX
used.
uplink cell
212, NO NO No
Indicates
[9500-9600]
selection. the
This and LBFD-002009
signal
none
UARFCN
becomes
signal
Normal
For an
transmission
evaluation
237, level
level
UTRAN =
a
UARFCNs:
262, 287) DL on
for cell FDDthe
frequency-specific
[10050-10125]
parameter is
threshold
Band
UARFCN
candidate
threshold
[8762-8912]
cell,
UTRAN the
selection.
Band 4:
3: way used
- for
used 475;
frequency.
During to in
in
offset
Special
required forUARFCNs:
the
in the NO NO No LBFD-00201803
reselection
The
Normal
It
the default
reselection.
reselection
Special
calculate
is evaluation
Normal used UARFCNs:
UARFCNs:
the
infor
UARFCNs: to
UL
to default
criteria
for
UTRAN
none
evaluation frequency.
neighboring
UARFCN
[1537-1738]
If
none
UL
S
cellthe
neighboring
to value
UARFCN
calculate
selection
[937-1288] is ofcells
cellsthis
varies
the
and on
on
It affects
Band 2:
reselection the only to a
a
a
The higher-priority
calculated
Special
parameter
lower-priority
dependingUARFCN
compensated
reselection UARFCNs:as
is
on
to less
a LOFD-001019
Special
probability
Normal
UTRAN UARFCNs: of NO NO No
UTRAN
follows
(1887,
than
UTRAN
range
whether
power. the
neighboring
none
triggering ifFDD
Forfrequency.
in1912,the
absolute
frequency.
the
each DLDLcell. A
1937,
details,
cell TDD on LOFD-002002
[9250-9550]
UE starts the and
UEs
frequency
1962,
priority
After
frequency
see
the
Band always
1987,
of
starting
3GPP
UTRAN4: for is theis
band
is
TS perform
2012,
a
a
measurement
[9650-9950]
evaluation
measurements
special
2037,
serving
measurements
shown
normal 2062,
one:
cell, 2087)
the for
forUE NO NO No LBFD-00201803
Specialas
25.104.
frequency,
Normal
reports
reselection or special
follows:
UARFCNs:
for the
to aUE
event
higher-priority
Band
starts
neighboring
Band
one.
calculates
[1312-1513] 2:
5:
the
1: UL the cells on
B1.
none For
neighboring details, UTRAN see
neighboring
UARFCN
Normal
measurements
the
Normal
The
Srxlev
Special UARFCNs:
lower-priority
default =
UARFCNs:
value
UARFCNs: cells.
DL
ULfor only
the A
3GPP
Band
FDD TS
3:
cell on 36.331.the NO NO No LBFD-00201803
UE
UARFCN
when
UTRAN considers
[4357-4458]
[9500-9600]
UARFCN
neighboring
(1662, the -
RX 400;
frequency,
1687, is and
cell a
signal
1712,
Normal
frequency
Indicates UARFCNs:
the only ifon
mobile
neighboring
Band
Special
level
the
based
1737, UE of
[10050-10125]
calculated 4:on UARFCNs:
UL
the
considers
1762, the as cell
serving
1787,
[9550-9650]
the
country RX signal
the
UARFCN
(1007,
cell
one
Special
follows is
following
1812,
Special
quality
low;ifcode
higher-priority
1012,
neighboring
1837,
of
=then
UARFCNs:
the
formula:
UARFCNs:
the
DL of ifthe
1032,
DL
1862) NO NO No LBFD-00201803
external
UTRAN
UARFCN
1037,
the
cell RX 1062, UTRAN
frequency
signal- 300;
1087)level
noneas5:=
none
frequency
Srxlev
Band
Indicates
neighboring
cell.
a Measured
candidate
the is cell
amobile is
as
Band
of
for
Band
normal
RSCP a
one candidate
5:
6:
2: UL
neighboring
reselection
one: ifforthe
Normal
Band
network
greater
The PLMN4:value
UARFCNs:
code
than ofof
the
consists
thethe
reselection
UARFCN
Normal
cell
RX
Normal
Band meets
signal
neighboring
[4132-4233] 1: UARFCNs:
=
UARFCNs:
UL theif
levelDL the
cell of - NO NO No LBFD-00201803
Normal
external
value
Indicates
of the of
MCC UARFCNs:
UTRAN
this
the and IDofof
RX
UARFCN
related
the signal
[4387-4413]
serving
[9250-9550]
UARFCN
Minimum
Special
[12850-13100]
cell.
-level
conditions,
=
RX
UARFCNs: 225;
cell
DLand
signalisthe
parameter.
the
MNC.
the
Band
Special external
neighboring
6: UARFCNs:
UL ForUTRAN cell
less than
[9650-9950]
UARFCN
level a-807,950;
(782,
Special
The
details,
cell.
The
is It-787,
PLMN
MCC
greater
UARFCN
(1037,
becomes
PowerUARFCNs:
see
uniquely
1062) =
a
consists
3GPP
consists
than DL the YES YES No LOFD-001019
specified
Special
Band
compensation.
812, 2:
837, threshold
UARFCNs:
UL
(2112,
of
TS the MCC
25.304.
identifies
of three 2137, a-862) and
UTRAN2162, the
value
UARFCN
Band
candidate
during
none
UARFCN
RSCP
Band
2187,
MNC.
7:
6:a digits.
ofis
2212,
this=for
short 225;
specified DL
2237, for
cell
The
Band
Normal within
parameterMNC
reselection. 7: UARFCNs:
UL a PLMN.
consists
during
Cells a
cell
Band
UARFCN
received
Normal
2262,
The
The
of
reselection
twoMCC 3:
2287,
28-bit threeUTRAN2312,of
-consists
signal
toUARFCNs:
400; YES YES No LOFD-001019
specified
UARFCN
[2237-2563]
different
time,
Normal
Band
code
[4162-4188]that
3:
power. cell
=
RATs
of
UARFCNs:
UL DL
the
For
2337)
of
cell three
digits. ID ishave digits.
comprised
reselection
UARFCN
Special
cannot
neighboring
[9550-9650]
UARFCN
details,
Special UARFCNs:
see -=225;
UARFCNs: timethe is
cell
DL
3GPP
Band
The
of
For theMNC 5:
cell
example, consists
ID and
MCC
and
For
(2587,
same
greater
Special
UARFCN
TS
(812, aother
TDD
25.304.
837)2612,
reselection
than related
UARFCNs:
- UTRAN
475; 2637,
the YES YES No LOFD-001019
Normal
of
the
= two
123,RNC to UARFCNs:
three
ID that are
conditions
2662,
cell,
priority.
value
none 7:
Band the
[11500-12000]
digits. 4: UL 45,
ofMNC
2687, UL
For
this are =
2712, met.
details,
represented
PLMN
For
2737,
UARFCN
see 3GPP =
details,
2762, 12345.
isTS seeby
2787,
the the
parameter
Band
UARFCN
Indicates
Normal
Special
For 4:
example, =
the
UARFCNs: during
DL type
MCC
least
3GPP
2812,
same
36.331. significant
TS
2837,
as the36.104.2862,
DL 16 NO NO No LOFD-001019
the
Normal
UARFCN
of
none
= cell
the
[2012-2338]
123, UTRAN
MNCreselection
UARFCNs:
- 2000;
= 45,cell.
bits
2887,
UARFCN. and 2912) the For most
time,
Band and
[12850-13100]
Band
Special
PLMN 5: UL other
6:=UARFCNs:
12345.
significant
Band
details, 8:2387,
see 123GPP bits,
related
Special
UARFCN
(2362,
Normal UARFCNs: conditions
UARFCNs:
= DL 2412, NO YES No LOFD-001019
respectively.
Normal
TS 25.104 UARFCNs: For
are
(2112,
UARFCN
2437, met.
[9400-9600] 2137,
2462, For - and
225;details,
2162,
2487,
details,
[2937-3088]
3GPP TS see 3GPP
25.105.
see
2187,
Band
2512,
Special 3GPP6:
2212,
2537, UL
UARFCNs:TS 2237,
2562,
TS
Special 25.331. UARFCNs:
36.104.
2262,
UARFCN
none 2287,
2587, 2612, = DL 2312,
2637, NO NO No LOFD-001019
none
2337)
UARFCN
2662, 2687) - 225;
For details,
Indicates
Indicates thesee
whether RNC
Band
Band 9:
5:
7:
Band
3GPP
ID set
to of the TSUL
8:
the 25.104
external
routing NO YES No LOFD-001019
Normal
Normal
UARFCN
Normal UARFCNs:
UARFCNs:
=TS
UARFCNs: DL
and
UTRAN
area 3GPP
code cell. (RAC) The for
[9237-9387]
[11500-12000]
UARFCN
[2712-2863] - 600;
25.105.
most
the significant
external UTRAN 12
Special
Special
Band
Special 8: UARFCNs:
UARFCNs:
ULRNC ID
UARFCNs:
bits
cell. of the
This parameter NO YES No LOFD-001019
none
none
UARFCN
none = DL
and cell
must be ID setoftoan CFG
The
Band
UARFCN
Band UARFCN
6:
9: - 225;
ifexternal
the
range externalUTRAN
inUARFCNs:
each TDD
Normal
Band
Normal
cell must 9: UL
UARFCNs:
be the NO NO No LOFD-001019
UTRAN
frequency cell
[9400-9600]
UARFCN
[8762-8912]
Indicates
same. =band
the DL is
supports
shown as packet
follows:
Special
UARFCN
Special
routing UARFCNs:
-
UARFCNs:
area 475;code of
switched
Band 1: (PS) NO YES No LOFD-001019
none
The
none
the default
external UL
UTRAN
services,In
Normal UARFCNs: other
For details,
UARFCN
The
cell. UARFCN is see
cases,
[9500-9600] this and
3GPP
calculated
range TS
in each25.104
as TDD
parameter
[10050-10125] is set to
and
follows
frequency3GPP if the TSDL is
band
NOT_CFG.
Special UARFCNs:
25.105.
frequency
shown as follows: is a
none
special1:one:
Band
Band
Band 2:
Normal 2: UARFCNs:
UL
Normal
UARFCN
[9500-9600] UARFCNs:
= DL and
[9250-9550] and
of the intra-RAT
neighboring relation
is prohibited.
UtranEventAnrSwitc
h: If this switch is
Indicates
turned on,the event-
primary
triggeredDL ANR with
scrambles
UTRAN of the
is enabled NO YES No LOFD-001019
external
to construct UTRAN and
Indicates
cell.
Indicates For details,the
the see
optimize inter-RAT
location
3GPP
threshold TS area 25.331.
above code
neighboring NO YES No LOFD-001019
of
which the external
a neighboring
relations with
UTRAN
cell of ancell.
Indicates the name
E-UTRAN
UTRAN cells by
threshold
of the
cell is added external below by for NO NO No LOFD-001019
triggering events
which
UTRAN
ANR. a neighboring
The cell. threshold
inter-RAT handover
cell
is the of percentage
an E-UTRAN of
to UTRAN. NO NO No LOFD-002001
cell
the is removed
number of by
GeranEventAnrSwit
ANR.
successful The threshold
ch: If this switch is
is the
Indicates percentage of
handovers
turned on,the from the
event- NO NO No LOFD-002001
the
number
serving number of
cell of the
to
triggered
Indicates ANR
the with
period
successful
handovers
neighboring based
cell to
GERAN
during is
which enabled
thethe
handovers
on
the which
total number ANR from NO NO No LOFD-002001
to
number construct of to and of
serving
makes
handovers. cell
decisions theon
optimize
handovers inter-RAT
neighboringisrelation
neighboring cell to
neighboring
measured by ANR NO NO No LOFD-002001
the total
setup or number
removal. of
relations
Indicates
to make decisions with
the
handovers.
Indicates the
GERAN
number
on neighboring cells
of by
periodic
switches
triggering for Mobility
relation setup or for
measurement
Indicates events
the NO NO No LOFD-002001
Robustness
inter-RAT
reports at handover
removal.sent
interval whichfor fast
Optimization
Indicates
to
ANR.
periodic GERAN. the (MRO)
fast
Indicates
algorithms.
ANR checking
UtranFastAnrSwitch the If the NO NO No LOFD-002001
measurement
Indicates the RSRP
maximum
switch
timer.If thisWhen
:reports for
switch aallowed
specific
the is for
threshold are sent
number
MRO
timer
turned is offor
algorithm
expired,
on, UEs
fast fast that
isthe
ANR LOFD-002001
fast
Indicates
ANR. ANR.If the the signal NO NO No
perform
enabled,
eNodeB
with UTRAN intra-RAT
fewer is LOFD-002002
maximum
quality
measurements
handover allowed
intoafailures for
automatically
enabled
number
neighboring
fast
will ANR.
occur of UEs
After cell that
the LOFD-002001
checks
construct
perform and theto
whether
inter-RAT NO NO No
reported
number
mobility
disable
optimize ofbyUEs
robustness
fast the UE
ANR.
inter-RAT LOFD-002002
measurements
is lower
performing
will be than
improved. theforIf
intra-
neighboring
fast ANR. After theis
threshold,
RATswitch
the
relations measurements
withthe
is turned cell NO NO No LOFD-002001
number
not
Indicates
for
off, fast of
automatically
ANR
the cells theUEs
Indicates
UTRAN the by
performing
added
minimum
reaches
corresponding tothe the inter-
required NRT.MRO
collective
performing switch
periodic
RAT
number
maximum
algorithm measurements
of is UEs
number, that NO NO No LOFD-002002
used
inter-RAT
Indicates to enable
the or
for
have
intra-RAT
disabled.fast ANR
performed
disable
measurements
minimum handover
required on
reaches
measurements
IntraFreqMroSwitch the for
and
UTRAN.
number CS fallback
ofThe UEs that NO NO No LBFD-00201801
LOFD-002001
maximum
fast ANR number,
before
will not
:eNodeB
If thisperformed
algorithms.
have
inter-RAT
switch
does is notbe LBFD-00201802
intra-RAT
performed
Indicates
turned
Fast
deliver CSon, fast
theonswitch
the
fallback
information ANR
other to LOFD-001019
measurements
can be for LOFD-001019
UEs.
for
eNodeB
UTRAN:
about the DL can
If
external ICIC
the NO NO No LOFD-002002
LOFD-001020
fast ANR before
automatically willadjustnot be LOFD-001020
algorithm.
dynamically
switch
UTRAN forcellsCS inANR the LOFD-001021
inter-RAT
performed
disabled. fast
on other LOFD-001021
The
the
fallback
measurement
Indicates value
intra-frequency
tothe UTRAN LOFD-001022
can
UEs. be NO NO No LOFD-001022
DlIcicReuse3Switch
handover
is turned off, this
configuration
switches to LOFD-001023
automatically LOFD-001023
_ON_ENUM
parameters
switch
UEs and
corresponding does the to
not
UEs to LOFD-001044
disabled. LOFD-001043
indicates
increase
takeinputs
measure
the effect; the
the
only
based intra-on NO NO No LOFD-001046
Reuse3 LOFD-001045
frequency
Fast
whichCS
neighboring
Indicates thealgorithm
handover
fallback
the
eNodeBUTRAN
switch to LOFD-001033
for
success
GERAN:
cells
for DL
the ICIC.rate;
contained
TCP If theThe
proxyif this
in LOFD-001044
LOFD-001034
determines LBFD-00202201
algorithm
switch
the is schedules
forturned
measurement
enhancer(TPE) CS off, NO NO No LOFD-001046
LOFD-001035
handover policies. LOFD-00101401
all
the
fallbackUEs onto
adjustment
configuration.
algorithm. to The theTPE
GERAN is LOFD-001033
edge
not
Therefore,
algorithm frequency
performed.
is turned off, this
if you
increases LOFD-001034
LOFD-002001
Indicates the switch NO NO No
band specified
InterFreqMroSwitch
switch
want does notin LOFD-001035
the
thatrate isexternal
usedof TCP to LOFD-002002
the
:UTRAN
take
services
control static
If this switch
effect. ICICadded
cells
by
whether is to LOFD-001019
scheme.
turned
by fast
measures on,
ANR
enable redirection In this
the
such with as NO NO No LOFD-001020
situation,
eNodeB
UTRAN to
copying
between
Indicates can
and allbeUEs in
E-UTRAN
the LOFD-001021
one
splitting
and
adjustmentcell
dynamically
measured other use
ACK only
adjust
inswitch
radio and
one
the
handovers,
locally
access
that third
is used of
inter-frequency
networks. the
to total
you are NO NO No LOFD-002009
frequency
handover
advised
retransmitting
enable and disableto band.
turn on
the
parameters
UtranEventAnrSwitc
ACK.
UL ICIC algorithm to LBFD-001001
increase the inter- NO NO No
h this
If
in as
thewell.switch
time is
domain. LOFD-001026
frequency
GeranFastAnrSwitc
turned
When handover
on, switch
this the TPE is
success
h: Iftothis
algorithm
set ON, rate;
isUL ifICIC
switch this
is NO NO No LOFD-00101402
switch
turned
enabled.
in the time is
on,turned
InfastthisANR
domain off,
the
with adjustment
situation,GERAN
is enabled in the the is is
not
enabled performed.
algorithm
cells under toisthe applied
UtranMroSwitch:
construct
to reaccessed
eNodeB. and and If
this
optimize switch
newly accessed
Otherwise, is
inter-RAT turned
UL ICIC
on, thetime
neighboring
UEs.
in the eNodeB domain can
dynamically
relations
If this
is disabled. switch with adjust
is
the
GERAN
turned UTRAN off,cellstheby TPE
occur
the frequencyin an
eNodeB,
domain. Ifbut this
fairness
switch isand set to OFF,
differentiation
UL ICIC inthe
Indicates the for
combined
frequency
Indicates
location services services
domain
the switch
are
is
for ensured.
(LCS) switch. the
disabled
reporting for PCI
A UE is considered
eNodeB
collision
OtdoaSwitch: cells. IfIf this
alarms. this
If
to
this have
switch
switch switch iscombined
is setis to
turned turnedon, LBFD-00202202
services ifstatic
the UE NO NO No
STATIC,
on, the PCI
OTDOA-based UL
collision LOFD-00101402
has
ICIC
alarm two
in is
positioningthe
Indicates or
the more
displayed
is period
flow-controllable
frequency
on
of the local
enabled.
MRO Ifdomain
this NO NO No LOFD-001047
non-GBR
is enabled
maintenance
switch
measurements. is bearers.
for the
turned off,
Fairness
eNodeBthe
terminal
OTDOA-based
During and
cells.
(LMT) period, If this
differentiation
switch
when
positioning
the numberaisPCIsetisof tofor NO NO No LOFD-00301102
combined
DYNAMIC,
collision
disabled. OTDOA
handovers amongservices
isdynamic is
are
UL ensured
ICIC
external
short
measured for incells the
Observed
and ifor
the
UL scheduling NO NO No LOFD-002007
frequency
among
Time
abnormal Difference domain
neighboring
scenarios of
algorithm
is
cellenabled
Arrival.occurs.
(including allocates
for
If the
this
Indicates the
Indicates the
bandwidths
eNodeB
switch
premature is cells.
turned to these off, NO NO No LOFD-002005
threshold
threshold
Indicates for the
for
the the
time
flow-controllable
the PCI
handover, collision
delayed
success
number
threshold rate
offor intra- of
ping-
non-GBR
alarm
handover, is not bearers
and ping-
handover
RAT
pong handovers.
handover. to intra-
based
displayed
pong
RAT
Indicates handover)
neighboring when Ifare
on weighting
the
a NO NO No LOFD-002005
Intra-RAT
UE
factorsis handed MRO is
over
such
identified.
cells,
threshold abelow
PCIfor collision
After thethe
which
applied
back to theand
(UlschPriorityFactor source
actually
period
intra-RAT
percentage occurs.
elapses,
MRO the
is
of intra-
parameter
cell
forafter
)eNodeB UL staying
scheduling in NO NO No LOFD-002005
Note that in
makes this
applied.
RAT
the ping-pong
adjustment
target
priorities. cell
If is fora a
this
situation,
decision
handovers, the
on above PCI
started
period
switch only
shorter
is turned when than
on,
collision
parameter
which still
parameter NO NO No LOFD-002005
the
this
the number
threshold,
scheduling of intra-
the
persists.
adjustment.
adjustment
RAT
eNodeB
algorithm
Indicates
handovers
mayis is index
the
performed
exceeds
decide
instructed this
thatto toalimit
ping-
of a simulated load NO NO No LOFD-002005
reduce
threshold.
pong
Indicates
the number the
handover the number
ofRB
configuration.
of ping-pong One
occurs
usage
resource
BS based
canthreshold blocks
store on of
10
handovers.
the
a history
simulated
(RBs) allocated Ifload
theto YES YES No None
simulated
percentage
Indicates load ispower
lower
the UE in the
information
configuration.
configurations, the about If
casethe
than
usage
this
RB
of UL the
UE.
usage threshold,
threshold
congestion.of a of
cell
which
parameter
a simulatedare identifiedload NO NO No None
is below
However,
by the indexes. thisaccording
adjustment
configuration.
threshold,
to the related theis notIf the
performed.
power
Indicates usage
simulated load the
specifications, the of a
switch
NO NO No None
cell
that is
is
scheduling
number below
used
ofthe tothis
is report
resource
Indicates
threshold,
control whetherthe to
performed.
blocks
period that
of aloadeach
simulated
enable
non-GBR and disable
bearer of NO NO No None
simulated
scheduling
the load
is
the frequency-
Indicates
UE can
configuration. the use is
performed.
selective
statistical
determined periodbased of
scheduling inload bit NO NO No None
a
onsimulated
the prioritized
simulated
configuration.
rates (PBRs) loadand
configuration.
priorities of theIf the NO NO No None
switch
associated is setlogical to ON,
Indicates
the frequency- the GPS-
channels
based rather
frame start
selective
than based on NO NO No None
time of
scheduling all TDD is cells
Indicates
UlschPriorityFactor.
under the
theIfeNodeB.
enabled.
number
As a result, the
of ports if this
switch is set to OFF, NO NO No LOFD-001026
that enable
switch is turned TCP on,
the frequency-
Indicates
fairness and port
acceleration. the
diversity
where thescheduling
differentiation TPEfor
NO NO No LOFD-001026
is used.
entity
combined processingservices is
Indicates
carried. the port
of one the
where UE TPE may be
affected. NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
carried.
Indicates the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where the TPE
NO NO No LOFD-001026
entity processing is
Indicates
carried. the port
where
Indicates thetheTPE URL NO NO No LOFD-001026
entity
of the certificate is
processing
carried.
Indicates
authority(CA). the nameThe LOFD-003010 /
of the certificate
URL can be either YES YES No
TDLOFD-003010
authority
an HTTP (CA).or HTTPS
URL. The IP LOFD-003010 /
NO YES No
address in the URL TDLOFD-003010
must be a valid
Indicates
IPv4 address.
Indicates the
whetherThe YES YES No LOFD-002004
mapping
default
the mapping identifier.
port number
is from
Indicates
Indicates the
the type
IDorof
is
one
of 80
the for
or HTTP
all
node, nodes to
the
443
a S-GW
for orwhich
HTTPS.
transmission peer NO YES No LOFD-002004
can
eNodeB.be S-GW If theornode
resource
peer eNodeB.group. If
is
thisanparameter
S-GW, theis
value NO YES No LOFD-002004
set to of thisall S-
YES,
parameter
GWs or peer must be
the
eNodeBs arethe ID
same as
NO YES No LOFD-002004
of the S-GW.
Indicates
mapped totheoneIf the
node
cabinet is
transmissiona peer
number of
eNodeB,
the
resource the value
targetgroup. NO NO No LOFD-002004
Indicates
of the
this parameter
transmission
subrack
must be number
the
resource group. same of
the
as thetarget
ID of the NO NO No LOFD-002004
transmission
peer eNodeB.
Indicates the slot
resource
number ofgroup. the
NO YES No LOFD-002004
target transmission
resource group.
Indicates the type
of the transmission NO YES No LOFD-002004
resource group.
Indicates the flag
ID of
that controls the
the target
Indicates
access of thethe type NO YES No LOFD-002004
transmission
of sub-board
unauthenticated
resource group. on the
board where
device to Local a
Indicates the NO YES No LOFD-002004
transmission
Area Network (LAN)
number
resource ofgroup
the port is
or Wireless Local
where
established.a
Area Network NO NO No LOFD-002004
transmission
Indicates the typethe
(WLAN) through
resource
of port where group a is
access port. This
carried.
transmission NO YES No LOFD-002004
parameter
Indicates is used
the
resource
Indicates
to guarantee group
the theis
number
carried.
authentication of the port
security
where theof 802.1x
the YES YES No LOFD-003015
method
transportofnetwork. the
authentication
802.1x is
When
configured.this
authentication.
parameter is set to NO NO No LOFD-003015
Currently,
ACTIVE, the only
Extensible
eNodeB still can
Authentication
Indicates
access thethe network NO NO No LOFD-003015
Indicates the cause
Protocol
number
ifofthe of- Transport
thenetwork
latest to be
IEEE
Layer
abnormal
accessed Security packets
does not
802.1x NO NO Yes LOFD-003015
(EAP-TLS),
received
support
Indicates theduring
the a the
802.1x
authentication
unidirectional
802.1x
authentication.
number If
failure orofthe thelatest
authentication
authentication.
the network
802.1x to be NO NO Yes LOFD-003015
situation where the
method,
accessed
authentication issupports
eNodeB does not
supported.
the 802.1x
failures.
initiate the
Indicates
authentication
Indicates the
the and NO NO Yes LOFD-003015
authentication.
Indicates the TrafficThe
number
the
802.1x
value of of
sharing mode not
eNodeB this is
Extensible
activated,the
authentication
parameter
between the
is state NO NO Yes LOFD-003015
Authentication
eNodeB
(Not
deleted
operators cannot
Authenticated,
upon in RAN the
Protocol
access
Being
completion
sharing the(EAP) network.
of a
scenarios.
packets
authenticated,
successful
Indicates
When thisreceived.
theIEEE NO NO Yes LOFD-003015
Authenticated,
Indicates
parameterthe
802.1x
number of is set to
Authentication
proportion
authentication.
Extensible
SHARING, ofthethe UL
Failed,
traffic DHCP
licenses to NO NO Yes LOFD-003015
Authentication
traffic
Indicates the does
license
Activation
the total of
Protocol
not
number Being
traffic
(EAP)
differentiate the
Authenticated).
licenses(The
packets sent.
between
802.1x the total NO NO Yes LOFD-003015
traffic
operators,is
authentication summation
that is,
of
all UL
thetraffic
successes. operators licenses
and DLthe
share traffic
total NO NO No LOFD-001036
Indicates
licenses).The
Traffic of the the BS
proportion
parameter
without proportional of
set to
operator
100% When 1's thisthe
indicates NO NO No LOFD-001036
limits.
Indicates the
capacity
null of DLintraffic
parameter the
is settotal
to
proportion
Traffic of theof BS
license . Thisthe
DEDICATE, may NO NO No LOFD-001036
operator
when the 2's
traffic
influence
traffic
Indicates license user's
the
capacity
license in the total
connecting.
differentiates
proportion ofBS
traffic of
differentiates the
between
operator the NO NO No LOFD-001036
when
between the3's traffic
the
operators,
capacity
Indicates
license in that
the is,
the total
operators.
all the
Traffic operators
of the BS
proportion
differentiates of NO NO No LOFD-001036
Indicates
share
when
operator the4's
the the
total
traffic
Traffic
between the
proportion
Traffic of
operators. BS inof
license
in the of
total the Traffic
operator
proportion.
differentiates
the BS when 1'sAn Traffic
the NO NO No LOFD-001036
Indicates
that can
operator, be theshared
whose
between
traffic license the
proportion
with
capacity of
otherisoperators
not
operators.
differentiates
operator
in
used,the total 2's
however, Traffic
traffic canof NO NO No LOFD-001036
between
that can bethe shared
the BS when
be used by other
operators. the
with
traffic other
operators.license operators
in the total
differentiates Traffic of NO NO No LOFD-001036
the
between the the
BS when
traffic
operators.license
differentiates
between the
operators.
Indicates the
proportion of
operator 3's Traffic
Indicates
that can be theshared
proportion of
with other operators
operator 4's
in the total Traffic Trafficof NO NO No LOFD-001036
that can
the BS when thebe shared
with
trafficother
license operators
in the total
differentiates Traffic of NO NO No LOFD-001036
the BS when
Indicates
between
Indicates the the
the
the ID of
first
traffic
the MME.
operators.
signaling license It should
IP
differentiates YES YES No LOFD-002004
be consistent
address
Indicates thewith
ofwhether
between
the
MME. theis, the
S1interfaceID.
That
the IPSec protocol
operators.
active
is usedpeer IP
to encrypt NO YES No LOFD-002004
Indicates
address
the data of thethe
transmitted
security
automatically-
on the SCTP gateway link LOFD-002004
Indicates
that has theIKE
the IPSec NO NO No
established
that is establishedSCTP LOFD-003009
proposal name
negotiation with
link.
through
needed thethe
for first the
peer
signalingeNodeB IP when LOFD-002004
IPSec negotiation NO YES No
FirstIPSecFlag
address of the is LOFD-003009
with
set tothe
Indicates local
ENABLE.the The
MME.
eNodeB when LOFD-002004
second
information aboutIP
signaling NO YES No
FirstIPSecFlag
address
this IKE peer
Indicates ofwhether
theneeds is LOFD-003009
set
MME.
to be
the to ENABLE.
Thatprotocol
configured.
IPSec is, the The LOFD-002004
information
standby
is used topeer about
encrypt IP NO NO No LBFD-002021
Indicates the
this
addressIPSec
the data of proposal
the of
transmitted LBFD-00202103
security gateway
needs
on the to
automatically-
SCTPbe link LOFD-002004
the MME
Indicates that
the IPSec has NO NO No
configured.
established
that is establishedSCTP LOFD-003009
the IKE
proposal namenegotiation
link.
through
with the for the
peer second
needed the LOFD-002004
signaling
eNodeB
IPSec IP
when
negotiation NO YES No
address of the is LOFD-003009
SecIPSecFlag
with the local
MME.
Indicates
set
eNodeBto ENABLE. the
when The LOFD-002004
number
information of the
about local NO YES No
SecIPSecFlag is LOFD-003009
port
this to
set ofENABLE.
IKE the
peer MME. needsThe
That is, the
to be configured.
information peer
about NO YES No LOFD-002004
port number
this IPSec of the
proposal
automatically-
Indicates
needs to be the
established
description
configured. of SCTP the NO YES No LOFD-002004
link.
MME.
Indicates the index
NO NO No LOFD-002004
of the operator.
Indicates the
cabinet number of
the board where the NO NO No LOFD-002004
Indicates
S1 servicethe IP
subrack
address number
is located. of
Indicates
the board the where local the NO NO No LOFD-002004
IP
S1address
Indicates
servicethe used
IP slotfor
local
number
the
IP address
address of
is the
IKE security required
located.
board
negotiationwhere
when automatically the S1
with NO YES No LOFD-002004
service
peer end
establishing IPwhen
address
thethe IP
Indicates
is located.
IPSecFlag
path on the whether
isS1 set to
the IPSec The
ENABLED. protocol
The YES YES No LOFD-002004
interface.
is used
automatically
DEVIP addressto encrypt
the databetransmitted
generated
should IPSec LOFD-002004
NO NO No
on the isIPbound
policy
configured path
to the that
to LOFD-003009
is
theestablished
board port where the
already. by
using the S1 The IP LOFD-002004
IP is located. NO NO No
Indicates
service IP the
address. LOFD-003009
address should be
cabinet
the IP address ofof
number
the
the board
Ethernet where port.theIt NO NO No LOFD-002004
Indicates
S1 signaling the IP
should
subrack be number of
address
configured is located.
to the the
the board where NO NO No LOFD-002004
board,
Indicates
S1 signalingand thethe slot
IP user
needs
number to ofensure
address is located.the
that the
board IP address
where the S1 NO YES No LOFD-002004
and S1ServIP
signaling IP are
configured
address at the
is located.
same physical port.
Indicates the locIP
address
Indicatesrequired the local
when
IP address automaticallyof the
establishing
Indicates
IKE security whether the
SCTP
to use link
the
negotiation with on
IPSec thethe
YES YES No LOFD-002004
S1 interface.
protocol
peer end when to The
encrypt
DEVIP
the dataaddress
LocIPSecFlag transmitted is set
should be The LOFD-002004
onENABLE.
to the SCTP link IP NO NO No
configured to thebe LOFD-003009
that
address is established
Indicates should
the
Indicates
board
on the the
already.
S1 local
interface
the IP address
standby local IP of LOFD-002004
IP
by address of the NO NO No
theusing
addressEthernet the active
required port. It LOFD-003009
IKE
IP security
address.
should
when
Indicates bewhether
automatically LOFD-002004
negotiation with the
configured
establishing
the tothe the NO NO No LBFD-002021
peerIPSecend when protocol
board,
SCTP and
link.
is used to encrypt the
The user
IP LBFD-00202103
SecLocIPSecFlag
needs
address
theset data to ensure
should
transmitted be LOFD-002004
is to ENABLE. NO NO No
that the
configured
on the IP address
to the
The IP SCTP
address link LOFD-003009
and
board
that LocIP
is
Indicates already. are
established
should bethe the IP
configured
by using of
minimum the
valueatactive
theof LOFD-002004
address
Indicates the the local NO NO No
same
IP
the physical
address.
Retransmission port. LOFD-003009
Ethernet
port number port.used It
TimeOut
should be(RTO). If
when automatically
the RTO
configured is tothe the NO YES No LOFD-002004
establishing
Indicates the
calculated
board, link
SCTP andon to the be
theuser
maximum
smaller than value RtoMin of
needs
S1 to
interface.
For Retransmissionensure
details about NO NO No LOFD-002004
the
in thethe SCTP
that
Indicates
the RtoAlphaIPthe address
initial
TimeOut
protocol, (RTO).
set the It
and
value SecLocIP
parameter, of the see are
provides
round-trip the upper
For detailsdelay
configured
Retransmission
RFC4960. at theto
about
Indicates NO NO No LOFD-002004
limit
RtoMin of theto(RTO). doubling
avoid the
same
the
TimeOut physical
RtoBeta port.
the value of
operation
unnecessary of the It is
parameter,
used
RtoAlpha. as the Itsee initial
is used
retransmission
timeout caused by NO NO No LOFD-002004
RFC4960.
value
as smooth when Indicates
factor of
timeout
low RTO. timer in the
the value
calculating
the round-trip of thedelay
SCTP protocol.
RtoBeta.
retransmission
Indicates
calculation Itthe is used
in the NO NO No LOFD-002004
as smooth
timeout
interval
SCTP protocol.in
between factor
the SCTPInofa
Indicates
the round-trip
protocol.
heart-beats. theThe delay
new estimation,
Indicates the
maximum
calculation
SCTP transmitsnumber
in theisthe NO NO No LOFD-002004
(RtoAlpha/100)
maximum number
of
SCTPretransmissions
heart-beat protocol. In a
taken
of from
retransmissions a new
for
new the SCTP
estimation,
information
a path.toWhen
measurement,
over
association. Whenthe
and NO NO No LOFD-002004
(RtoAlpha/100)
destination
1-(RtoAlpha/100) address is is
the number
the number of of
taken
to monitor
Indicates from
taken from the last the
the
whether
retransmissions
retransmissions for
offset gain, and
reachability 1-
to
over
the a path of
calculate
estimation.
association
thethe NO NO No LOFD-002004
(RtoBeta/100)
idle
checksumdestination of value
theis
exceeds
exceeds
Indicates the
the
whether value
taken
address
packet from
to on be the
the
sent.last
peer
of
of
to this
this parameter,
parameter,
calculate the
estimation.
end.
If checksum NO NO No LOFD-002004
the path iswhether
Indicates
the SCTP
checksum regarded
link
of is
calculation
as failedthat ifback
nois the
to switch
broken
packet and a
is to
link
enabled,
heartbeat the
the
failureprimary
received. alarm path
is NO NO No LOFD-002004
checksum
acknowledgment of the
when
reported.
If checksumthe primary is
packet
received. to be sent is
path of If is
calculation multiple
calculated.
paths are If a
used, NO NO No LOFD-002004
automatically
enabled, the
checksum
path switching erroris
establishing
checksum
Indicates the S1
ofsender
the
type
occurs,
automatically the
SCTP
received
of thenot is restored.
packet
checksum is NO NO No LOFD-002004
does
performed. send the
The SCTP link
calculated.
calculation. If a is
packet.
switched
checksumtoerror the
secondary
occurs, thepath receiver NO NO No LOFD-002004
Indicates
when thethe the
primary
discards packet.
consecutive
path cannot be heart-
beat
Indicates
reached; number the of
This peer the NO NO No LOFD-002004
switch
SGW
parameter ID of required
the is used
Indicates
active/standby
for thewhether the first path.
to set the YES YES No LOFD-002004
service
automatically IP address set up
SCTP link switches
of the
Indicates
S1 SGW.
service whether
linkThat and is,
back to the primary
the
the first peer IP
pathIPSec
security when protocol
connection.
the NO YES No LOFD-002004
address
is used to ofencrypt
the
primary path is
automatically-
the data transmitted
restored. LOFD-002004
established
on the IP path S1that IP NO NO No
path. LOFD-003009
is established
through the first
service IP address
of the SGW.
Indicates the
security gateway of
the SGW that has
Indicates the IPSec
the IKE negotiation
proposal
with the peer name
needed
eNodeBfor when the LOFD-002004
IPSec negotiation NO YES No
ServIP1IPSecFlag LOFD-003009
with
is setthe
Indicates local
the
to ENABLE.
eNodeB
second when IP
service
The information LOFD-002004
NO YES No
ServIP1IPSecFlag
address
about this ofIKEthe peer LOFD-003009
Indicates
is set to whether
SGW.
needs toENABLE.
That beis, the
the
The
secondIPSec peerprotocol
information
Indicates the IP NO NO No LOFD-002004
configured.
is used
about
security to
this encrypt
ofIPSec
address gateway the of
the
the data transmitted
proposal
SGW
automatically- needs
that has to
Indicates the IPSec LOFD-002004
on
be
the the IP path
configured.
IKE negotiation
established S1 IP that NO NO No
proposal name LOFD-003009
is established
with
path. the peer
needed
through
eNodeB when for
the the
second LOFD-002004
IPSec
service negotiation
IP address NO YES No
ServIP2IPSecFlag LOFD-003009
with
is thethe
of set local
SGW.
to ENABLE.
Indicates
eNodeB the third
when LOFD-002004
The
serviceinformation
IP address NO YES No
ServIP2IPSecFlag
about this IKE peer LOFD-003009
of the
Indicates
is SGW. whether
set totoENABLE. That is,
needs
the third be
peer IP
the
The IPSec
Indicates protocol
information
the NO NO No LOFD-002004
configured.
address ofencrypt
the of
is usedthis
about
security to IPSec
gateway
automatically-
the
the data transmitted
proposal
SGW needs
that has to
established
Indicates theS1 IP
IPSec LOFD-002004
on
be the
the IKEIPnegotiation
path
configured. that NO NO No
path.
proposal name LOFD-003009
is established
with the peer
needed
through
eNodeB when for
the the
third LOFD-002004
IPSec
service negotiation
IP address NO YES No
ServIP3IPSecFlag LOFD-003009
with
is thethe
of set local
SGW.
to ENABLE.
Indicates
eNodeB the fourth
when LOFD-002004
The
serviceinformation
IP address NO YES No
ServIP3IPSecFlag
about this IKE peer LOFD-003009
of the
Indicates
is SGW. whether
set totoENABLE. That is,
needs
the fourth bepeer IP
the
The IPSec
Indicates protocol
information
the NO NO No LOFD-002004
configured.
address ofencrypt
the of
is usedthis
about
security to IPSec
gateway
automatically-
the
the data transmitted
proposal
SGW needs
that has to
established
Indicates theS1 IP
IPSec LOFD-002004
on
be the
the IKEIPnegotiation
path
configured. that NO NO No
path.
proposal name LOFD-003009
is established
with the peer
needed
through
eNodeB when for
the the
fourth LOFD-002004
IPSec
service negotiation
IP address NO YES No
ServIP4IPSecFlag LOFD-003009
with
is thethe
of set local
SGW.
to ENABLE.
eNodeB when
The information LOFD-002004
NO YES No
ServIP4IPSecFlag
about this IKE peer LOFD-003009
is set totoENABLE.
Indicates
needs the
be
The information
description
configured. of the NO YES No LOFD-002004
about
SGW. this IPSec
proposal
Indicates needsthe index to
be configured. NO NO No LOFD-002004
of the operator.
Indicates the
cabinet number of
the board where the NO NO No LOFD-002004
Indicates
X2 servicethe
Indicates the IP local
subrack
address
IP address number
is located.
required of
the
when board where
automatically the NO NO No LOFD-002004
Indicates
X2 servicethe slot
IPthe
establishing
number of IP
address
path is the
located.
boardon the
where X2
the X2 NO YES No LOFD-002004
interface. The
service IP address IP
address
is located.theshould be
Indicates local
configuredwhether to the YES YES No LOFD-002004
IP
the address
IPSec of the
protocol
board already. This
IKE
is usedsecurity
to encrypt
IP address
Indicates is
thewith the LOFD-002004
negotiation
the data to transmitted NO NO No
allowed
whether the beIPSec
the LOFD-003009
peer
on end
thewith when
IP path that
same
negotiation that of
IPSecFlag
is established isisset
held
by to LOFD-002004
the S1SigIP,
through the security NO NO No
ENABLE.
using The
X2ServIP. IP LOFD-003009
X2SigIP,
gateway and
when
address should be
S1ServIP
IPSecFlag MOs.
is set
the IP address ofto LOFD-002004
ENABLE. NO NO No
the Ethernet port. It LOFD-003009
should be
configured to the
board, and the user
needs to ensure
that the IP address
and X2ServIP are
configured at the
Indicates the name
of the security
gateway that has
the IKE negotiation
Indicates
with the local the name
of the
eNodeB whenIPSec LOFD-002004
proposal NO YES No
IPSecFlagwhen and LOFD-003009
IPSecFlag
SeGWFlagand are set
SeGWFlag
to ENABLE.are Theset LOFD-002004
NO YES No
to ENABLE.
Indicates
information The
theabout LOFD-003009
information
cabinet number
this IKE peer needs of the of
IPSec
the proposal
to be configured. the
board where NO NO No LOFD-002004
Indicates
needs
X2 signalingto be the IP
subrack
configured. number
address is located. of
the board
Indicates where
the active the NO NO No LOFD-002004
Indicates
X2 signaling the IP slot
local
number IP address
of the
address
required is
whenlocated.
board where the X2 NO YES No LOFD-002004
automatically
signaling IP
Indicates
establishing whether
the
address
Indicates
the IPSec isthelocated.
local
protocol
SCTP signaling link YES YES No LOFD-002004
IP address
is used of
to encrypt the
on the X2 interface.
IKE
the security
data transmitted
The IP address
Indicates thewith LOFD-002004
negotiation
on the SCTP linkthe NO NO No
should
whether be the IPSec LOFD-003009
peer
that isend when
established
configured
negotiation to the
IPSecFlag
on the already. isisset
X2 interface held to LOFD-002004
board
Indicates
through the the name
security NO NO No
ENABLE.
by using the active The IP LOFD-003009
of the security
gateway
address when be
should
local IP address.
gateway
IPSecFlag
the IP address that is sethas ofto LOFD-002004
the IKE
ENABLE. negotiation NO NO No
the Ethernet
Indicates the port.nameIt LOFD-003009
with
should thebe local
of the
eNodeB IPSecwhen LOFD-002004
configured
proposal whento the NO YES No
Indicates
IPSecFlag theand LOFD-003009
board,
IPSecFlag and the user
and
standby
SeGWFlag local areIPset
needs
SeGWFlag to ensureare
address
to
thatENABLE. required
the IP address Theset NO YES No
LOFD-002004
to ENABLE.
when automatically
information The
about LOFD-003009
and LocIPwhether
Indicates
information areofthe the
establishing
this IKE peer needs LOFD-002004
configured
Indicates
the
IPSec IPSec the
proposal at local
protocolthe
SCTP
to be signaling link
configured. NO NO No LBFD-002021
same
IP
is used
needs physical
address tobe of the
encrypt port.
on the to X2 interface. LBFD-00202103
IKE
the security
data
configured. transmitted
The IP address
Indicates thewith LOFD-002004
negotiation
on the SCTP linkthe NO NO No
should
whether be the IPSec LOFD-003009
peer
that isend when
established
configured
negotiation tois the
held
SecIPSecFlag
on the already.
X2 interface is LOFD-002004
board
Indicates
through the the name
security NO NO No
set to ENABLE.
by using the active The LOFD-003009
of
IP the
gateway
addresssecurity
when should
standby IP address.
gateway
be the IPthat
SecIPSecFlag address has is LOFD-002004
the
set IKE
to negotiation
ENABLE. NO NO No
of the Ethernet
Indicates the name port. LOFD-003009
with
It the local
should be
of the
eNodeB IPSecwhen LOFD-002004
configured
Indicates
proposal the
whento the NO YES No
SecIPSecFlag
board,
number andof thelocal
the and
user LOFD-003009
SecIPSecFlag
SecSeGWFlag
Indicates the and
are
needs
port used
SecSeGWFlag to ensure
for are LOFD-002004
set
that to
minimumtheENABLE.
automatically IP value
address ofThe NO YES No
set to ENABLE.
information
the Retransmission about The LOFD-003009
and SecLocIP
establishing
information an
of are
theX2
this
TimeOutIKE
configured
SCTP peer
link. (RTO).
at
When needs
theIf
IPSec
to
the beRTO proposal
configured.
is NO NO No LOFD-002004
same
the
needs mode
Indicates physical
to be of port.
the
calculated
automatic to be
X2 linkof
configured.
maximum
smaller than value RtoMin
establishment
thetheRetransmission is set NO NO No LOFD-002004
in
to SCTP
X2_OVER_S1,
Indicates the initial
TimeOut
protocol,
Indicates (RTO).
set
the the value It
this
value parameter
provides of the the uppermust
round-trip
of
be RtoAlpha.
set to
Retransmission delay
36422. It isto NO NO No LOFD-002004
limit
RtoMin
used ofas the
to doubling
avoid
smooth the
TimeOut
operation
Indicates (RTO).
of round-
the thevalue It is
unnecessary
factor
used asof the
the initial
retransmission
of RtoBeta.
timeout
trip delay caused It is by NO NO No LOFD-002004
value
timeout whentimer in
used
low as
RTO.
calculation
calculating
smooth in
the thethe
SCTP
factor
SCTP protocol.
of the
protocol. In around-
retransmission
trip delay NO NO No LOFD-002004
new
timeout estimation,
in the SCTP
calculation
(RtoAlpha/100) in the is
protocol.
SCTP protocol. In a
taken from a new NO NO No LOFD-002004
new estimation,and
measurement,
(RtoBeta/100)
1-(RtoAlpha/100) is is
taken from
taken from the last the
offset gain, and 1-
estimation.
(RtoBeta/100) is
taken from the last
estimation.
Indicates the
interval between
Indicates
heart-beats. theThe
Indicates
maximum the
number
SCTP
maximum transmits number the
of retransmissions
heart-beat
of
for retransmissions
the SCTP
information
over a path.toWhen Whenthe
association. NO NO No LOFD-002004
destination
the number
number of address
of
the
to monitorwhether
Indicates the
retransmissions
retransmissions for
reachability
to
over a path of
calculate thethe NO NO No LOFD-002004
the
idle association
destination
checksum of value
the
exceeds
exceeds
Indicates the
the
whether value
address
packet
of this to on be
parameter, the
sent. peer
of
to
end.
If this
checksumparameter,
calculate the NO NO No LOFD-002004
the
the path
SCTPiswhether
Indicates
checksum regarded
link
of is
calculation
as failedthat ifbackis the
no
to switch
broken
packet and a
is to
link
enabled,
heartbeat the
the primary
failure
received. alarm path
is NO NO No LOFD-002004
checksum
acknowledgment of the
when
reported.
If the primary is
checksum
packet
received. to be sent is
path of If is
calculation multiple
calculated.
paths arethe If
used, a NO NO No LOFD-002004
automatically
enabled,
checksum
path switching erroris
establishing
checksum
Indicates the X2
ofsender
the
type
occurs,
automatically the
SCTP
received
of thenot is restored.
packet
checksum is NO NO No LOFD-002004
does
performed. send the
The SCTP link
calculated.
calculation. If a is
packet.
switched
checksumtoerror the
secondary
occurs, the receiver path NO NO No LOFD-002004
when
discards
Indicates thethe primary
the packet.
heart-
Indicates
path number
beat cannot thebe ID the
of of a
neighboring
reached; NO NO No LOFD-002004
switch
Indicates of This
the
the first
eNodeB.
parameter
active/standby The is usedlocal
path.
signaling
eNodeB IP
to set whether the YES YES No LOFD-002004
address
distinguishes of theits
SCTP link switches
neighboring
Indicates
neighboring whether
back to the primary
eNodeB.
the IPSec
eNodeBs That
protocol is,
path whenbased the on NO YES No LOFD-002004
the
is active
used
their IDs. to peer
encrypt IP
primary path is
address
the data of the
transmitted
restored.
Indicates the LOFD-002004
automatically-
Indicates
on the SCTP the peer link NO NO No
whether
established
IP the IPSec
X2 LOFD-003009
thataddress
is established of the
negotiation
SCTP
IKE
through the is
link.
security held
first LOFD-002004
through
negotiation
signaling IP the security
with the NO NO No
Indicates the LOFD-003009
gateway
local
address. endwhen when
second
FirstIPSecFlag
FirstIPSecFlagsignaling is IP
is LOFD-002004
address
set to of
ENABLE. the NO NO No
set to ENABLE. LOFD-003009
neighboring
Indicates
This IP address whether LOFD-002004
eNodeB.
the
needs IPSecto be That
protocol is,
NO NO No LBFD-002021
the
is standby
used to encrypt
configured for theIP
peer
LBFD-00202103
address
the data of the
transmitted
Ethernet port of the
Indicates
automatically-
Indicates the
the peer LOFD-002004
on
peer the SCTP
eNodeB. link NO NO No
whether
established
IP the IPSec
X2 LOFD-003009
thataddress
is established of the
negotiation
SCTP
IKE
through the is
link.
security held
second LOFD-002004
through
negotiation
signaling IP the security
with the NO NO No
LOFD-003009
gateway
local
address.
Indicatesendwhen when
the
SecIPSecFlag
number of the port is LOFD-002004
NO NO No
set to ENABLE.
of the neighboring LOFD-003009
Indicates
This
eNodeB. IP address the first
That is,
service
needs to
the peer port IP be address NO NO No LOFD-002004
of the neighboring
configured
number of the for the
eNodeB.
Ethernet port
automatically- Thatofis,the
Indicates
the first whether
available NO NO No LOFD-002004
peer eNodeB.
established X2
the
peer IPSec
IP address protocol of
signaling
is used link.
to encrypt
the automatically-
Indicates the peer LOFD-002004
Indicates the
the data transmitted NO NO No
established
whether the X2 IP LOFD-003009
IP
on address
the IP path ofIPSec
the
that
path.
negotiation
IKE securityis held
is established by LOFD-002004
through
negotiation
using ServIP1.
Indicates the security
thewith the NO NO No
LOFD-003009
gateway
local end
second service IPwhen
when
ServIP1IPSecFlag
ServIP1IPSecFlag
address of the LOFD-002004
is NO NO No
is set
set toto ENABLE.
neighboring ENABLE. LOFD-003009
This IP address
eNodeB. That is,
needs
the to be
second NO NO No LOFD-002004
configured
available peer for the IP
Ethernet
address of theof the
port
peer eNodeB.
automatically-
established X2 IP
path.
Indicates whether
the IPSec protocol
is used to encrypt
Indicates
Indicates the
the peer LOFD-002004
the data transmitted NO NO No
whether
IP the ofIPSec LOFD-003009
on address
the IP path the
that
negotiation
IKE security
is established is held
by LOFD-002004
through
negotiation
using ServIP2.the withsecurity
the NO NO No
LOFD-003009
gateway
local endwhen
Indicates when
the third
ServIP2IPSecFlag
ServIP2IPSecFlag
service IP address LOFD-002004
is NO NO No
is set
of the to
set to ENABLE.
ENABLE.
neighboring LOFD-003009
This IP address
eNodeB. That is,
Indicates
needs
the third whether
to available
be NO NO No LOFD-002004
the IPSec
configured
peer IP addressprotocol
for theof
is used
Ethernet
the toport
encrypt
automatically- of the
Indicates
Indicates the
the peer LOFD-002004
the
peerdataeNodeB.
established transmitted
X2 IP NO NO No
whether LOFD-003009
IP
on
path.the IPthe
address ofIPSec
path the
that
negotiation
IKE securityis held
is established by LOFD-002004
through
negotiation
using ServIP3.the withsecurity
the NO NO No
LOFD-003009
gateway
local endwhen
Indicates when
the fourth
ServIP3IPSecFlag
service IP address LOFD-002004
is NO NO No
of set
the to ENABLE.
neighboring LOFD-003009
This IP address
eNodeB. That is,
Indicates
needs
the fourth to be whether
available NO NO No LOFD-002004
the IPSec
configured
peer IP addressprotocol
for theof
is used
Ethernet
the toport
encrypt
automatically- of the
Indicates
Indicates the
the peer LOFD-002004
the
peerdataeNodeB.
established transmitted
X2 IP NO NO No
whether LOFD-003009
IP
on
path.the IPthe
address ofIPSec
path the
that
negotiation
IKE securityis held
is established by LOFD-002004
through
negotiation
using ServIP4.the withsecurity
the NO NO No
LOFD-003009
gateway
local endwhen when
Indicates
ServIP4IPSecFlag
ServIP4IPSecFlag the mobile LOFD-002004
country
is set to code
ENABLE. of the NO NO No
is set to ENABLE. LOFD-003009
peer eNodeB.
Indicates
This IP This
the mobile
address
parameter
network
needs tocode is closely
be of the NO NO No LOFD-002004
associated
peer eNodeB.
configured
Indicates thewith
for IDthethe
This
of
CGI of
parameter
Ethernet
the the cell,
is and
closely
port of the
peer eNodeB,
is
peera part
associated
which eNodeB.(3 decimal
uniquely with the NO NO No LOFD-002004
digits)
Indicates the CGI.
CGI of
identifies of
the the
ancell, and
is a part (2
eNodeB
common to 3 aof
within
name
decimal digits) of NO YES No LOFD-002004
PLMN.
the This
certificate
the CGI. the
parameter
request
Indicates is closely
associated with
configuration,
description of the the
which NO YES No LOFD-002004
CGI
can of the
be
X2eNodeB. the cell, and
Indicates
is a part ofthe
electronic theindex
serial CGI.
Indicates
additional the
number (ESN), NO NO No LOFD-002004
of the operator.
information that is
media access
added
control (MAC) the
behind LOFD-003010 /
value of the NO NO No
address, or IP TDLOFD-003010
COMMNAME
address of a board.
parameter
Upon generation to of LOFD-003010 /
NO YES No
compose
the certificate a TDLOFD-003010
complete
Indicates
request file, common
the the
name forwhere
the the LOFD-003010 /
country
value of the NO YES No
certificate request TDLOFD-003010
eNodeB
specifiedistype located.
is
Indicates
file. The the
default
used as the LOFD-003010 /
organization
value is name that NO YES No
common of TDLOFD-003010
owns the eNodeB.
".huawei.com".
Indicates the
the file.
organization unit LOFD-003010 /
NO YES No
that owns the TDLOFD-003010
Indicates
eNodeB. the state
or province where LOFD-003010 /
NO YES No
the eNodeB is TDLOFD-003010
located. the
Indicates
LOFD-003010 /
specific location of NO YES No
TDLOFD-003010
the eNodeB.
purpose that the
key serves,
including
KEY_AGREEMENT
(key negotiation),
DATA_ENCIPHER
Indicates
MENT (data the
signature
encryption), algorithm LOFD-003010 /
for the certificate NO NO No
KEY_ENCIPHERM TDLOFD-003010
request
ENT (key file. The
signature
encryption), algorithm
and LOFD-003010 /
NO NO No
can be Secure
DIGITAL_SIGNATU TDLOFD-003010
Indicates
Hash the size
Algorithm 1 of
RE
the (digital
key, which can LOFD-003010 /
(SHA1) or
signature). NO NO No
be 1024 bitsThis
Message-Digest or TDLOFD-003010
parameter
2048 bits.the can be
Indicates
Algorithm 5 local
(MD5).
set to one or LOFD-003010 /
name of the NO YES No
multiple values. TDLOFD-003010
eNodeB.
Indicates the local
LOFD-003010 /
IP address of the NO NO No
TDLOFD-003010
eNodeB.
Indicates the file
LOFD-003010 /
name of the device YES YES No
TDLOFD-003010
certificate.
Indicates the serial
LOFD-003010 /
number of the NO NO Yes
TDLOFD-003010
device certificate.
Indicates the
common name of LOFD-003010 /
NO NO Yes
the device TDLOFD-003010
certificate.the issuer
Indicates
LOFD-003010 /
of the device NO NO Yes
TDLOFD-003010
certificate.the
Indicates
expiration date of LOFD-003010 /
NO NO Yes
the device TDLOFD-003010
Indicates
certificate.the date
when the device LOFD-003010 /
Indicates NO NO Yes
certificatethe begins to TDLOFD-003010
application
take effect. type of
the activated device LOFD-003010 /
YES YES No
certificate. There TDLOFD-003010
Indicates
are two types:the file
IKE
name
and SSL.of the LOFD-003010 /
NO YES No
activated device TDLOFD-003010
certificate.
Indicates the issuer
LOFD-003010 /
of the activated NO NO Yes
TDLOFD-003010
device
Indicatescertificate.
the
common name of LOFD-003010 /
NO NO Yes
the activated device TDLOFD-003010
Indicates
certificate.the serial
number of the LOFD-003010 /
NO NO Yes
activated device TDLOFD-003010
Indicates
certificate.the
expirationthe
Indicates dateIKEof LOFD-003010 /
NO NO Yes
the
name activated
of the peerdevice TDLOFD-003010
certificate.
device, which is
LOFD-003010 /
used in IKE NO YES No
Indicates thewith
date TDLOFD-003010
negotiation the
when the activated
local end to test the LOFD-003010 /
device
device certificate
certificate. NO NO Yes
TDLOFD-003010
begins to the
Indicates take
effect. status of
loading LOFD-003010 /
NO NO Yes
the activated
Indicates the device TDLOFD-003010
certificate.
certificate
LOFD-003010 /
application type NO NO Yes
TDLOFD-003010
supported by the
Indicates
eNodeB. the file LOFD-003010 /
name of the cross- YES YES No
TDLOFD-003010
certificate.
Indicates the serial
LOFD-003010 /
number of the NO NO Yes
TDLOFD-003010
cross-certificate.
Indicates the
LOFD-003010 /
common name of NO NO Yes
TDLOFD-003010
the cross-certificate.
Indicates the issuer
LOFD-003010 /
of the cross- NO NO Yes
TDLOFD-003010
certificate.
Indicates the
LOFD-003010 /
expiration date of NO NO Yes
TDLOFD-003010
the cross-certificate.
Indicates the
LOFD-003010 /
loading status of NO NO Yes
TDLOFD-003010
the cross-certificate.
Indicates the date
when the cross- LOFD-003010 /
NO NO Yes
certificate begins to TDLOFD-003010
take effect.
Indicates the file
LOFD-003010 /
name of the trust YES YES No
TDLOFD-003010
certificate.
Indicates the serial
LOFD-003010 /
number of the trust NO NO Yes
TDLOFD-003010
certificate.
Indicates the
LOFD-003010 /
common name of NO NO Yes
TDLOFD-003010
the trust certificate.
Indicates the issuer
LOFD-003010 /
of the trust NO NO Yes
TDLOFD-003010
certificate.
Indicates the
LOFD-003010 /
expiration date of NO NO Yes
TDLOFD-003010
the trust certificate.
Indicates the
LOFD-003010 /
loading status of NO NO Yes
TDLOFD-003010
the trust certificate.
Indicates the date
when the trust LOFD-003010 /
Indicates NO NO Yes
certificatethebegins to TDLOFD-003010
loading status of
take effect.
Indicates
the the file
CRL. Possible LOFD-003010 /
YES YES No
name of
states arethe CRL.
normal, TDLOFD-003010
certificate loss,
LOFD-003010 /
certificate damage, NO NO Yes
TDLOFD-003010
failure due to
unknown
Indicates thefile issuer LOFD-003010 /
format, NO NO Yes
of the CRL. failure
and TDLOFD-003010
due to other
Indicates the next
causes. LOFD-003010 /
update time of the NO NO Yes
TDLOFD-003010
CRL.
Indicates the latest
LOFD-003010 /
update time of the NO NO Yes
TDLOFD-003010
CRL.
Indicates the IP
address of the FTP LOFD-003010 /
NO YES No
server or LDAP TDLOFD-003010
Indicates
server. the user
name for logging in LOFD-003010 /
NO YES No
to the FTPthe
Indicates server or TDLOFD-003010
LDAP server.
password for
LOFD-003010 /
logging in to the NO YES No
Indicates whether TDLOFD-003010
FTP server or
to update the
Indicates the port
CRL
LDAP server. LOFD-003010 /
at the next
number update
of the NO NO No
time TDLOFD-003010
LDAPspecified
server. in the
CRL
Indicates is
that the file LOFD-003010 /
obtained during the NO YES No
name of the CRL. TDLOFD-003010
latest update. If this
parameter is set to LOFD-003010 /
NO NO No
ENABLE, the TDLOFD-003010
eNodeB
automatically
updates the CRL
from the FTP server
or LDAP server
when the next
update time arrives.
Indicates the
interval at which the
eNodeB
LOFD-003010 /
automatically NO NO No
TDLOFD-003010
obtains the
Indicates theCRL ID of
fromtask
the the for FTP server LOFD-003010 /
or LDAP server. YES YES No
periodically
Indicates the TDLOFD-003010
obtainingwith
method thewhichCRL.
LOFD-003010 /
the eNodeB NO NO No
TDLOFD-003010
periodically
Indicates theobtains
policy
Indicates
the CRL.
type. There theare
LOFD-003010 /
distinguished
three policies name to use NO YES No
TDLOFD-003010
of the LDAP
Indicates
CRLs. Thethe whetherserver.
value
Indicates
threshold the
the task offor
NOVERIFY a
checking LOFD-003010 /
method
certificate to expiration
update a NO NO No
the certificate
indicates that TDLOFD-003010
certificate
alarm. Ifisthe thatthe
validity
Indicates
eNodeB started.
the
does period
not
expires
eNodeB ordetects
is about LOFD-003010 /
of checking
perform
to expire. CRL-basedthe
There are NO NO No
that the interval TDLOFD-003010
certificate
two methods: validity.
checks. proxy
between
The value its current
ALARM
and CMP. If the LOFD-003010 /
time and the
indicates that the NO NO No
proxy method TDLOFD-003010
expiration
eNodeB dateisof
performs
used,
an the eNodeB
activated device
CRL-based LOFD-003010 /
uses the M2000
certificate
Indicates is
the shorter as NO NO No
certificate checks TDLOFD-003010
the
than proxy
maximum the to
threshold,
wait update
time
on
the the peer device
certificate from
a
forcertificate
an
Indicates echo thean LOFD-003010 /
and
the reports
Certificate NO NO No
expiration
response
maximum alarm
of
numberan is TDLOFD-003010
alarm
Authority if the (CA). If
reported.
echo
of request
timeouts
certificate of
is found the
the CMP method
message. If no is NO NO No None
echo
in response
the CRL. The
used,
echo the eNodeB
response is
waiting
value timer. If no
directly
received updates
duringisthe the
echo
DISCONNECTresponse
certificate
Indicates
period from
the theby
specified the NO NO No None
received
indicates after
that the
CA.
Indicates
Differentiated
this parameter, the action the
number
eNodeB specified
performs
taken
Services
timer
by this on the data is
Code
expires.
parameter
CRL-based
that matches the NO NO No None
Point
reached, (DSCP) itchecks
is an of the
certificate
ACL rule. When the
GTP-U
Indicates
indication control
the ID
ofdevice
GTP-U of
on
ACL theto peer
which the LOFD-003009
message.
the
path Access
failure. Control YES YES No
and
ACL stops
rule belongsthe is LOFD-00301401
List (ACL).
Indicates
communication the brief with
referenced
Indicates the by a
description
the peerfilter,device of theif LOFD-003009
packet
filtering condition the BS NO YES No
Access
the Control
certificate
Indicates the is List
ID of LOFD-00301401
accepts
for the or
source transmits
port.
(ACL).
found
the in
Access the CRL.
Control
the
If data
this that
parameter is LOFD-003009
List
matches(ACL) the to rule
which if YES YES No
set to OP_LT, the LOFD-00301401
the
this ACL
parameterrule is
ACL
belongs.rule is
Indicates the applied
IDand of LOFD-003009
set
to to PERMIT,
the data stream YES YES No
the ACL
rejects rule.
the dataport if LOFD-00301401
whose source
this
number parameter
is smaller is
LOFD-003009
set
thantoorDENY. equal When to the NO NO No
Indicates LOFD-00301401
the ACL
Indicates
configured isthe
the port
Indicates
source the
IP address
referenced
protocol
number. type by an
wildcard
of data to
If theof the
this
ofwhich NO YES No
LOFD-003009
IPSec
data to
parameter
source
policy,
which is set
IPisaddress. thethe
the to LOFD-00301401
ACL
BS
ACL rule
encrypts
rulethe applied.
or
is applied.
OP_GT,
The wildcard ACL
is
To add anthe
decrypts ACL data rule LOFD-003009
rule
used istoapplied
determine to NO YES No
that is applicable
matches the to LOFD-00301401
the
which data bits stream
can be IP
data
rule of
if thisall source
whose
neglected source when portIP LOFD-003009
addresses,
parameter
Indicates isset
whether setthis to NO YES No
number
address is larger
matching is LOFD-00301401
parameter
PERMIT,
to check and
the to does
source
than
being orperformed.
Indicates equalthe to the
0.0.0.0.
not
port perform
number any
of be LOFD-003009
configured
Generally,
source portitor port
can
number NO YES No
encryption
each
number. data stream
If this LOFD-00301401
considered
used when as the is
SMPT
decryption
before
parameter applying onset
is the the
to
inverse
set toifYES. of the If SOP LOFD-003009
data
ACL
OP_EQ, this
rule. the ACL NO YES No
corresponding
is set to LOFD-00301401
parameter
rule is applied is set to to
subnet
OP_RANGE, mask. this
DENY.
the data stream
parameter indicates LOFD-003009
whose source port NO YES No
the smallest source LOFD-00301401
number
port number.is equal If SOP to
thenot
is configured
set to port
number.
OP_RANGE, If thisthis
parameter
parameter is set to
indicates
OP_NEQ,
a specific source the ACL
rule is
port applied to
number.
the data stream
parameter is set to
OP_LT, the ACL
rule is applied
Indicates the to
the data stream
source port number
whose
used when destinationSMPT is
port
set number is
Indicates theIf SOP
to YES.
smaller
Indicates
is set to the than or
destination IP
equal
wildcard
OP_RANGE, to the
of the thisto LOFD-003009
address of data NO YES No
configured
destination
parameter port
IP rule
indicates LOFD-00301401
which the ACL
number.
address.
the largest IfThe
this
source
is applied. To add
parameter
wildcard
port number. is is
usedset
Thisis to LOFD-003009
an ACL rule that NO YES No
OP_GT,
determine
parameter which the ACL
is valid LOFD-00301401
applicable to data
rule
bits
only is
can
whenapplied
beSOPtoisIP
of all
Indicatesdestinationwhether LOFD-003009
the
set data
neglected
to stream
OP_RANGE. when IP NO YES No
addresses,
Indicates
to check the
the set this LOFD-00301401
whose destination
address matching is
parameter to
destination port
port
being number
performed. is LOFD-003009
0.0.0.0. used
number of iteach when NO YES No
larger
Generally, than orcan equal be LOFD-00301401
DMPT
data
to is
stream
the configuredset to
before
considered as the
YES.
applying If DOP is set
Indicates
port
inverse number.ofthe theACL
the If this
NO YES No
LOFD-003009
to OP_RANGE,
rule.
destination
parameter is set this
port to LOFD-00301401
corresponding
parameter
number
OP_EQ, used indicates
when
subnet mask.ACL the
the
rulesmallest
DMPT is set toto
is applied LOFD-003009
NO YES No
destination
YES.
the data If DOP stream port
is set LOFD-00301401
number.
to OP_RANGE,
whose destinationIf DOP is
this
not set to LOFD-003009
parameter
port number is indicates NO YES No
Indicates
OP_RANGE, whether LOFD-00301401
the
equal to the this
largest
to check
parameter the DSCP
configured indicates
destination port
port LOFD-003009
of
a each
specific
number. This data stream NO NO No
If this LOFD-00301401
before
destination
Indicates
parameter applying isport
the valid the
set to
ACL
number.
only rule.
Differentiated
when the DOP is LOFD-003009
OP_NEQ, ACL NO YES No
Services
set
ruleto Codeto
is OP_RANGE.
applied LOFD-00301401
Point
Indicates
the data (DSCP). whether
stream LOFD-003009
to match
whose
Indicates the the
destination NO NO No
LOFD-00301401
fragment
port number
Indicates
source IPmessage.
the is not
address
equal
of the to
cabinet BFD thesession.
No. to
configured port YES NO No LOFD-003007
which
The a BFD
source IP
Indicates
number.
session If the
this
belongs.
address of a BFD
subrack
parameter No.is to set
session must be to a YES NO No LOFD-003007
which
OP_RANGE, a BFD the
device IP address
session
ACL rulebelongs.
Indicates the
is slot
applied
of a specified board
No. to
Indicates
to the which
data
(for example, the the a
stream BFD IP YES YES No LOFD-003007
session
destination
whose
address of an belongs.
destinationIP
address
port number
Indicates
Ethernet of the
port)theisIDorBFD
of
aa
session.
within the If Virtual YES YES No LOFD-003007
BFD session.
logical IP address
Router
configured
Indicates
(for Redundancy
example, therange.
hop
the IP
Protocol
type
address of aof (VRRP)
BFD the is NO YES No LOFD-003007
used
session.
loopback in the Theport), single
but
network,
cannot betwo
Hop BFD setBFD
session to the is
sessions
used to
IP address of a must
perform be NO YES No LOFD-003007
configured
point-to-point
remote with the
destination
detection
maintenance
Indicates inIP
the thetype
addresses set to NO YES No LOFD-003007
data
channel.link
Indicates
of the BFD layer.
Note
thesession. The
that
the
a thisactive
multi-hop
BFDparameter
minimum
If session and
BFD
intervalisat
standby
session
cannot
which
set to the be physical
is used toIP
BFD NO NO No LOFD-003007
addresses
Indicates
perform
configured
session
MAINTENANCE, of
theasthe
end-to-end
transmits a
virtual
minimum
connectivity
single-hope
control
the router,
BFDpackets. interval
session check
session at
is
respectively.
which
in the the
transport
if its source
used BFD
for continuity IP NO NO No LOFD-003007
session
layer.
address receives
is
check
Indicates
control
(CC). theIflogical
packets.
a this
IP address.
parameter
detection multiplier is set to NO NO No LOFD-003007
RELIABILITY,
of a BFD session. the
BFD session is
used to trigger NO NO No LOFD-003007
route interlock.
Indicates the
Route interlock
Differentiated LOFD-003007
enables NO NO No
Servicesthe Code LBFD-00300201
Indicates
standby
Point (DSCP). whether
route to
to
takedelete
overthe once the NO NO Yes LOFD-003007
statistical
active route
information.
becomes faulty, and
therefore prevents
service interruption
caused by route
failures.
Indicates the state
NO NO Yes LOFD-003007
of a BFD session.
Indicates the
effective detection
NO NO Yes LOFD-003007
mode through
Indicates
negotiation. the
effective minimum
NO NO Yes LOFD-003007
TX interval through
Indicates
negotiation. the
effective minimum
NO NO Yes LOFD-003007
RX interval through
Indicates
negotiation. the
detection the
Indicates timelocal
when
NO NO Yes LOFD-003007
the negotiation
discriminator of the
takes effect. The
BFD session.
value of this
Indicates the IP NO NO Yes LOFD-003007
parameter
address at is
theequal
Indicates
to the the
session peer
Ethernet
descriminatorport or NO NO Yes LOFD-003007
number
Ethernet plus
trunk 1.of a
BFD session.
Indicates the
corresponding to
number
the RMEP. of The IP
NO NO Yes LOFD-003007
transmitted
Indicatesbound
address thepacketsto
of a
numberBFD of
the remote MEPsession.
messages
cannot be the received
same NO NO Yes LOFD-003007
by
as the
the BFD
existing local
Indicates
session. the up-to-
IP address
down number of a or any NO NO Yes LOFD-003007
IP address
Indicates
BFD the
session. of an
effective
diagnostic physical
field of or
Indicates
loopback the
port. The
the BFD session, NO NO Yes LOFD-003007
interface
bound
that is, IP index
theaddress
cause of of
a
BFD
cannot session.
be
the failure. the For
same
thethe
as BFD session
local IP in NO NO Yes LOFD-003007
multiple-hop
address mode,
Indicates
the interfacethe index
name
dynamically
of
is the
0. MD to which YES YES No LOFD-00300402
negotiated on the
the RMEP belongs.
PPP/MLPPP
Indicates the link. name
When the to
of the MA IP which YES YES No LOFD-00300402
address
the RMEP is belongs.
bound,
the
Indicates theIPRMEP
existing
address of the YES YES No LOFD-00300402
ID.
system may conflict
with the IP address
YES YES No LOFD-00300402
to be configured,
run the LST/DSP
Indicates the name
(DEVIP,
of the MD OMCH,
to which YES YES No LOFD-00300402
PPPLNK,
the MA belongs.LOCALIP,
MPGRP,
Indicates or theIPRT)
name
command YES YES No LOFD-00300402
of the MA. to query
the IP address
Indicates cabinet of
the system
number of the (such as
NO NO No LOFD-00300402
deviceto
board IPwhich
address, the
Indicates
localbelongs.
MA subrackof
IP address
number
the remote of the
NO NO No LOFD-00300402
board to
maintenance which the
Indicates
MA belongs. slot
channel,
number oflocal the IP
address NO YES No LOFD-00300402
board to of the PPP
which the
link, IP
Indicates address
MA belongs. whether of
localis
the MA
maintenance NO NO No LOFD-00300402
associated with the
Indicates
channel, local
VLAN. the ID IPof
the VLANofwith
address the NO NO No LOFD-00300402
which
MLPPP the MA isor
group,
associated.
the next hop IP
address) that
conflicts with the IP
address to be
bound. The fault
needs to be cleared
manually.
Indicates the
priority of the VLAN
NO NO No LOFD-00300402
with whichthe
Indicates the MA
is associated.
interval at which the
CFM MA transmits NO NO No LOFD-00300402
continuity check
Indicates
messagesthe (CCMs).
number of local NO NO Yes LOFD-00300402
MEPs in an MA.
Indicates the
number of RMEPs NO NO Yes LOFD-00300402
in an MA.
Indicates the list of
local MEPs in an NO NO Yes LOFD-00300402
MA.
Indicates the list of
NO NO Yes LOFD-00300402
RMEPs in an MA.
Indicates the name
YES YES No LOFD-00300402
of the CFM MD.
Indicates the level
NO NO No LOFD-00300402
of the CFM MD.
Indicates the
number of MAs in a NO NO Yes LOFD-00300402
CFMMD.
Indicates the list of
all MAs in a NO NO Yes LOFD-00300402
CFMMD.
Indicates the name
of the MD to which YES YES No LOFD-00300402
the MEP belongs.
Indicates the name
of the MA to which YES YES No LOFD-00300402
the MEP belongs.
Indicates the MEP
YES YES No LOFD-00300402
ID.
Indicates cabinet
number of the
NO NO No LOFD-00300402
board to which the
Indicates subrack
MEP belongs.
number of the
NO NO No LOFD-00300402
board to which the
Indicates slot
MEP belongs.
number of the
NO YES No LOFD-00300402
board to which the
Indicates the type
MEP belongs.
of subboard on the
NO YES No None
board where the
MEP is located.
Indicates the port
NO YES No LOFD-00300402
type of MEP.
Indicates the port
NO YES No LOFD-00300402
number of the MEP.
Indicates whether
to enable the
NO NO No LOFD-00300402
continuity check
Indicates
(CC) of the the ID of a
CFM.
VLAN of the MA to
NO NO Yes LOFD-00300402
which the MEP
Indicates
belongs. the ID of a
VLAN of the MA to
NO NO Yes LOFD-00300402
which the MEP
Indicates
belongs. the
priority of a VLAN
NO NO Yes LOFD-00300402
of the MA to which
the MEP belongs.
Indicates the
number of
transmitted NO NO Yes LOFD-00300402
Connectivity
Indicates the Check
(CC) packets.
number of received
NO NO Yes LOFD-00300402
Connectivity Check
Indicates the
(CC) packets.
number of
NO NO Yes LOFD-00300402
transmitted
loopback packets.
Indicates the
number of received NO NO Yes LOFD-00300402
loopback packets.
Indicates the
number of
NO NO Yes LOFD-00300402
transmitted PDUs
Indicates
traced over thea link.
number of received
NO NO Yes LOFD-00300402
PDUs traced over a
Indicates
link. the
number of
NO NO Yes LOFD-00300402
transmitted packets
Indicates
CFM packets.the
number of
NO NO Yes LOFD-00300402
transmitted
Indicates thepackets
CFM packets.
number of
transmitted packets NO NO Yes LOFD-00300402
CFM packets
Indicates the
discarded.
number of received
NO NO Yes LOFD-00300402
packets
IndicatesCFMthe MAC
packets discarded.
Indicates
address ofthe
thename
of the MD
RMEP. to which
It must be a YES YES No LOFD-00300402
the RMEP
valid unicast belongs.
Indicates
address inthe thename
of the MA to
format of XXXX- which YES YES No LOFD-00300402
the RMEP belongs.
XXXX-XXXX. The
Indicates
MAC the RMEP
address of the YES YES No LOFD-00300402
ID.
RMEP can be
obtained from the
MAC address field NO NO No LOFD-00300402
carried in the CCM
message.
Indicates the If the
status
MAC address NO NO Yes LOFD-00300402
of the RMEP.
Indicates the actual
configured
MAC address by the
of the
user is different
RMEP. The format NO NO Yes LOFD-00300402
from
is that carried in
XXXX-XXXX-
Indicates the
the
XXXX.CCM message,
priority of a VLAN
the MAC address NO NO Yes LOFD-00300402
of the MA to which
carried in the
Indicates the IDMAC
of a
the RMEP belongs.
message
VLAN prevails.
of the MA to
NO NO Yes LOFD-00300402
which the RMEP
Indicates
belongs. the
number of received
NO NO Yes LOFD-00300402
CCM packets from
Indicates
the RMEP.the
number of the IP
NO NO Yes LOFD-00300402
addresses bound to
the RMEP.the list of
Indicates
the IP addresses NO NO Yes LOFD-00300402
bound to the
Indicates the RMEP.
type
of the
YES YES No LOFD-003014
commissioning
service.
Indicates the
number of the YES YES No LOFD-003014
commissioning port.
physically located
at the local
maintenance
Ethernet port. If this
parameter is set to
DISABLE, the
commissioning
service is disabled
on the local NO YES No LOFD-003014
maintenance
Indicates the
Ethernetnumber
cabinet port. If of this
parameter is set to YES NO No None
the board where the
Indicates
ENABLE,
port is located.the
the
subrack
commissioning number of
YES NO No None
the board
service where the
is enabled
Indicates
port the slot
is located.
on the local
number of the
maintenance YES YES No None
board where the
Ethernet
Indicates port.
the type In
port is located.
this case, the
of sub-board on the local
maintenance YES YES No None
board where a port
Ethernet
is located.port is
Indicates
subject tothe cyber port
YES YES No None
type.
attacks to the
commissioning port.
Indicates
Enable this theswitchport
YES YES No None
number.
with causion.
Indicates the IP
address configured YES YES No None
Indicates
for the port. the
subnet mask of the
device IP address NO YES No None
configured on the
Indicates
port. whether LBFD-00300102
to enable the DHCP NO NO No LBFD-00300103
relay switch. LOFD-002004
Indicates the rule IP LBFD-00300102
Indicates
for
address ofwhether
prioritizing thetraffic YES YES No LBFD-00300103
to
to
DHCPenable
meetserver. detection
service LOFD-002004
of automatic If this
requirements.
establishment
parameter is set of to NO NO No LOFD-002004
the remote
IPPRECEDENCE,
Indicates the
maintenance
the protocol
priority
Indicates thestack
of the high- NO NO No LBFD-00300201
channel.
of the earlier
level OM
Indicates
priority of data.
the
signaling. The
version
priority is adopted,
has ahas
priority
The of the
priority low- a
which
positive firstly NO NO No LBFD-00300201
level
positiveOMcorrelation
data, such
correlation
converts
Indicates
with the types
thetoDSCP
value of
of
as
with the
thedatavalue be
ofto
service
of
thisthe IP (TOSs)
clock
parameter. The
uploaded
this parameter. or NO NO No LBFD-00300201
DSCPs
packet.
high-level and
If the
OM then
clock
data
downloaded. The
prioritizes
that follows traffic.
includes
priority hasthe athe
Precision
packets Time
related
positive correlation to NO NO No LBFD-00300201
Protocol
remote
with (PTP)ofis
the value
used, the DSCPThe
maintenance
this parameter. of
Indicates
the PTP the
packets NO NO No LBFD-00300201
channel
low-level switchover
priority
takes of OM
effect. user data
data
If the
and DHCP
includes the relay.
data
type
clock 1. The
that priority
follows
related
has Huawei to File
a positive NO NO No LBFD-00300201
the
Transfer Protocol
correlation
Indicates
proprietary the with type
protocol the
(FTP).
value of this
of primary
is used, thetransport
DSCP
parameter. NO NO No None
resource
of the protocol for user
Indicates
data type the
1. effect.
packet takes
primary port load
Indicates NO NO No None
threshold the of user
threshold
data type of 1. the
primary-to-
Indicates the NO NO No None
secondary
priority of user portdata load
ratio of user
type 2. The priority data
type
has a1.positive NO NO No LBFD-00300201
correlation
Indicates the with typethe
value of this
of primary transport
parameter. NO NO No None
resource for user
data type 2.
Indicates the
primary port load
Indicates NO NO No None
threshold the
of user
threshold
data type of2. the
primary-to-
Indicates the NO NO No None
secondary portdata
priority of user load
ratio 3.
type of The
userpriority
data
typea2.positive
has NO NO No LBFD-00300201
correlationthe
Indicates with the
type
value
of of this
primary transport
parameter. NO NO No None
resource for user
Indicates
data type the
3.
primary port load
Indicates NO NO No None
threshold the
of user
threshold
data type of3. the
primary-to-
Indicates the NO NO No None
secondary portdata
priority of user load
ratio 4.
type of The
userpriority
data
typea3.positive
has NO NO No LBFD-00300201
correlationthe
Indicates with the
type
value
of of this
primary transport
parameter. NO NO No None
resource for user
Indicates
data type the
4.
primary port load
Indicates NO NO No None
threshold the
of user
threshold
data type of4. the
primary-to-
Indicates the NO NO No None
secondary portdata
priority of user load
ratio 5.
type of The
userpriority
data
typea4.positive
has NO NO No LBFD-00300201
correlationthe
Indicates with the
type
value
of of this
primary transport
parameter. NO NO No None
resource for user
Indicates
data type the
5.
primary port load
Indicates NO NO No None
threshold the
of user
threshold
data type of5. the
primary-to-
Indicates the NO NO No None
secondary portdata
priority of user load
ratio 6.
type of The
userpriority
data
typea5.positive
has NO NO No LBFD-00300201
correlationthe
Indicates with the
type
value
of of this
primary transport
parameter. NO NO No None
resource for user
Indicates
data type the
6.
primary port load
Indicates NO NO No None
threshold the
of user
threshold
data type of6. the
primary-to-
Indicates the NO NO No None
secondary
priority portdata
of user load
ratio 7.
type of The
userpriority
data
typea6.positive
has NO NO No LBFD-00300201
correlationthe
Indicates with the
type
value
of of this
primary transport
parameter. NO NO No None
resource for user
Indicates
data type the
7.
primary port load
Indicates NO NO No None
threshold the
of user
threshold
data type of7. the
primary-to-
Indicates the NO NO No None
secondary
priority portdata
of user load
ratio 8.
type of The
userpriority
data
typea7.positive
has NO NO No LBFD-00300201
correlation with the
value of this
parameter.
Indicates the type
of primary transport
NO NO No None
resource for user
Indicates
data type the 8.
primary port load
Indicates NO NO No None
threshold the of user
threshold
data type of 8. the
This parameter
primary-to-
Indicates the
belongs NO NO No None
secondary
priority ofto a data
port
user load
feature
ratio
type of
9. called
user
The LMPT
data
priority
This
Downlink
type parameter Flow
has
belongsa8.positive
to a S1 NO NO No LBFD-00300201
Control.
correlation Whenwith the
Indicates
feature called the type
LMPT
interface
value of downlink
this
of primaryFlow
Downlink transport
traffic
parameter. volume NO NO No None
resource When
Control. for user S1
exceeds LBBP
Indicates the
data
interfacetypedownlink
9.
process port
primary ability,load CPU
traffic
Indicates
in LBBP volume the
will NO NO No None
threshold of user
exceeds
threshold LBBP
of
overload
data typeand 9. theit will
process
primary-to-
lead ability, CPU
to degradation
in LBBP willport load NO NO No None
secondary
of air interface
overload
ratio of
throughput. userandTo it will
data
lead
type to
9. degradation
solve this problem, NO NO No None
of
LMPTair interface
Downlink
throughput.
Flow ControlTois
solve
Indicates
used to this problem,
the
limit NO NO No None
LMPT
number Downlink
downlink rate of theof
Flow
LMPT in caseisof the
cabinet Control
housing
Indicates
used the an YES NO No None
LBBPtoCPU
board limit
where
number
downlink
E1/T1 of the
rate
portThis is of
overload.
subrack
LMPT
located. in housing
case of
parameter indicates YES NO No None
the
LBBP board
Indicates CPU where the
the
whether to limit
E1/T1
overload.
number port
ofThisis slot
the
LMPT downlink
Indicates the clock rate
located.
parameter
housing theinindicates
board YES YES No None
measured
mode of the bit per
E1/T1
whether
where
second the toE1/T1
(bps) limit
port.
Indicates
LMPT
port is the in rate
downlink
located.
case
1. If the
number of LBBP
BS
of inthe CPU
extracts YES NO No None
measured
overload. packet
the
per line
E1/T1 second clock
port. fromin
(pps)
the E1/T1
Indicates
case of LBBP port,
the rangethe
Indicates the CPU NO NO No None
clock
of mode
E1/T1mode
overload. of
ports.of the
working
E1/T1 port must be
the E1/T1 port. This
set to SLAVE. If the
parameter must be NO NO No None
BS provides the line
set to the same
clock
Indicates for the thelower-
frame
value as that at the
level
format equipment
used by the NO YES No None
peer end.
through
E1/T1 port. the E1/T1
Indicates
port, the clock link
the line
running
coding status.
mode
mode of the E1/T1 ofThean NO YES No None
link
E1/T1
port running
mustport. bestatus
set to
is classified into
MASTER.
OK, LOCAL_LOOP, NO NO No None
Otherwise, the line
REMOTE_LOOP,
clock may fail to
Indicates
PAYLOAD_LOOP, whether
work properly.
to perform the link NO NO Yes None
SINGLE_CH_LOOP
2. When the the test
E1/T1
test
,port and
type. provides
The testan types 8K
PHYSICAL_LOOP,
clock reference for NO NO Yes None
are
LOS, classified
AIS, RA,into LFA,
the
No transmission
Test, Offline
Indicates
LMFA, SLIP,whether
interfaceand board,
Test,E1/T1 Online the
the
BACKUP, port is
and NO NO Yes None
clock
Test. mode of the
used.
OTHERS.
E1/T1
Indicates portthe must
left be
set to SLAVE.
loop time of the NO NO Yes None
Indicates
3. The port.
E1/T1 clockthemodes
type
of sub-board
E1/T1 ports used on the
board where the
by an inter-board YES YES No None
E1/T1
MLPPPport group is
located.
cannot be all set to
SLAVE.
Indicates the BER
NO NO No None
threshold.
Indicates the
cabinet number of
the board where the YES NO No LOFD-00300401
Indicates
Ethernet port the is
subrack
located. number of
the board where the YES NO No LOFD-00300401
Indicates
Ethernet port the slotis
number
located. the of
board where the YES YES No LOFD-00300401
Indicates
Ethernet port the typeis
of sub-board on the
located.
Indicates the
board where the YES YES No None
working mode of
Ethernet port is
the Ethernet port
located.
Indicates the type
that complies with YES YES No LOFD-00300401
of
IEEE 802.3ah. port.
the Ethernet
Indicates
If this parameter the is
number
set to ACTIVE,
Indicates of the the
whether YES YES No LOFD-00300401
Ethernet
local
remote end port.
initiates
loopback
Indicates
negotiation.
can be enabled the period at
for sending a frame NO NO No LOFD-00300401
If this
the port parameter
where is
3AH
for
set fault detection.
to PASSIVE,
detection is A
the
shorter
local end does
activated. time interval
not
If remote NO NO No LOFD-00300401
indicates
initiate
loopback ais higher
negotiation;
frequency
Indicates
instead, the
enabled, the oflocal
the size of
OAM
detecting
the
endProtocol
3AH waits
loopback the
forData
ais NO NO No LOFD-00300401
Ethernet
Unit
allowed.(PDU).
negotiation link details,
For faults.
message
see the STR from the
NO NO No LOFD-00300401
peer end.
ETHOAMLOOPTST
command.
Indicates whether During
the loopback,
Indicates the
to enable indication only NO NO No LOFD-00300401
3AH
threshold
of link packets
faults.
Indicates the for rather
the
than
erroneous
duration
Indicatesother ofthe types
the of
frame
packet can NO NO No LOFD-00300401
event. If
Errored Frame
threshold the forbenumber
the
transmitted.
of erroneousIf
Event.
accumulated
Indicates
remote
frames the
loopback
within a is
erroneous
duration ofthe frame
thelocal
Error NO NO No LOFD-00300401
disabled,
second
event. exceeds
IfSeconds
the length the
Frame
end cannot
threshold, an initiate
of time thatEvent.
Summary
the loopback.
erroneous
erroneous frame
frames NO NO No LOFD-00300401
The
event Error
occurs. Frame This
occupy
Seconds within
indicates a
event
sampling is checked
period
the
every number
other of error
second. NO NO No LOFD-00300401
specified
frames per through
second.
the
Indicates the FSM
ERRFRMSCDEVT
status of
Indicates the the NO NO Yes LOFD-00300401
PRD
Ethernet
number parameter
ofOAM 3AH.
exceeds
discardedthe OAM
threshold, an Units NO NO Yes LOFD-00300401
Protocol Data
accumulated
(PDUs) onthe the RX
Indicates
erroneous
channel.of received frame
number NO NO Yes LOFD-00300401
event occurs.
Event OAM PDUs.
Indicates the
number of received NO NO Yes LOFD-00300401
Fault
Indicates OAMthe PDUs.
number of Info
NO NO Yes LOFD-00300401
OAM
Indicates PDUs the
Indicates
received ontheatotalport.
number
number of received
of received
OAM PDUs, NO NO Yes LOFD-00300401
Loopback Control
including
OAM PDUs. the
information OAM
NO NO Yes LOFD-00300401
PDUs, event OAM
PDUs, loopback
OAM PDUs, and
discarded OAM
PDUs.
Indicates the
number
Indicatesofthe
discarded
number of OAM NO NO Yes LOFD-00300401
PDUs on theEvent
transmitted TX
Indicates
channel.
OAM PDUs. theThe
number of PDUs NO NO Yes LOFD-00300401
Event OAM
transmitted
are used to Fault notify
OAM
Indicates
the peer PDUs. theThe
end of a NO NO Yes LOFD-00300401
Fault
number OAM
link event. of PDUs
Indicates
are used to
transmitted theInfo
notify
number
the peer
OAM PDUs. The ofend of a NO NO Yes LOFD-00300401
transmitted
link failure.
Indicates
Info OAM the PDUs totalare
loopback
number
used to finish ofOAMthe
PDUs.
search The
transmitted process. OAM NO NO Yes LOFD-00300401
loopback
PDUs, OAM the
including
PDUs are used
information OAMfor
remote loopback NO NO Yes LOFD-00300401
PDUs,
Indicates the OAM
event
control.
PDUs, loopback
cabinet number of
OAM
the PDUs,
board where and the YES NO No None
Indicates
discarded
Ethernet port the
OAM is
subrack
located. number of
PDUs.
the board whether
Indicates where the YES NO No None
Indicates port
Ethernet the slot is
to enableofthe
number theARP
Indicates
located. the
proxy
board function.
where theIf YES YES No None
Maximum
Indicates
the ARP
Ethernet the type
proxy
port is
Transmission Unit
of sub-board
function
located. is on the
enabled,
(MTU)
Indicates at the
the
whether speed
board
the where the
system YES YES No None
Ethernet
mode
the of the
Ethernet port,port which
Ethernet
performs port
the ARP is is
identifies
Indicates
Ethernet
an electrical the
port. This
located.
proxy on the port IP or
maximum
number
parameter
optical port. of IP the
mustpacket be YES YES No None
addresses ofWhen
size
Ethernet
set
the to(including
the
system port.
sameis the
loopback interfaces
IP header)
value of ofthe
on theas
started, BSthethat thethe
orsystem IP NO YES No None
Ethernet
peer
binds port. port.
GE
the Ethernet The
addresses of ports
recommended
electrical
portthe with ports MTU
an
on lower-level
value
support
electricalis above
1000 576.
Mbit/s
BS. If the port
Indicates the
ARPduplex first if NO NO No None
If
thethe
only value
when
default is
working
of the is of
mode function value
proxy
smaller
in
the port than
auto-negotiation
Ethernet attribute
port. 576,is
disabled, the If the
broadcast
mode. packets
systemIfdoes
AUTO.
SPEED SPEED
parameter not of NO NO No None
such
a set as
is GE the DHCP
optical
to AUTO, portthis is
perform the ARP
packet
set to
parameter may
AUTO, fail
must the to
proxy on the IP NO NO No None
be
alsoreceived
port works
be set at or1000
to
addresses of
transmitted.
Mbit/s
AUTO. inIf auto-
the This
loopback
Indicates interfaces
the
parameter
negotiation does not
SPEED
on the BS
generation ormode.
parameter the IPIf NO NO No None
take
SPEED
is effect
not set to of after
a GE the
addresses
Indicates
threshold ofAUTO,
whether
for ports
Ethernet
optical
this
on port
parameter
the
Indicates
port
lower-level
the isthe
is
setmust to
to
MAC enable
added Excessive
tothe the flow
an
1000M,
be
BS. set to
In this FULL. port
case, NO NO No None
clearance
control
Frame
Ethernet
works at
ontrunk.
Error
1000
the Ratethe
threshold
external
for the
Ethernet
alarm MAC
(ID: device
port.
25881).
Mbit/s
whose
Excessive in
IPmanual
address
Frame is
When the
configuration number mode. NO NO No None
on
ErrortheRate
of erroneous same subnet
alarmMAC
as
(ID: the
frames IP
25881). address
exceeds When of
this
the loopback
number
Indicates
threshold,the of
theMAC MAC NO NO No None
interface
erroneous
address
Excessive onFrame
(six MACthe
bytes) BS
(or
framesof
configuredthe falls
Error Rate alarm islower-below
for the
level
this BS) port.
threshold, needs theto NO NO Yes None
Ethernet
reported. The
Indicates
access
MAC the
Excessive
format is XXXX- the
physical
loopback
Frame
XXXX-XXXX. layer
Error interface
Rate NO NO Yes None
status
(or theis
alarm of the
lower-level
cleared.
Ethernet
BS) through
Indicates port.
thea
route. This
loopback status of NO NO Yes None
Indicates
parameter
the Ethernet whether
doesport.not
the current
take effect after Ethernet the
port
Ethernetis in the port is NO NO Yes None
loopback
added to an test
mode.
Ethernet trunk.
Indicates whether
the Ethernet OAM NO NO Yes None
3AH is enabled.
Indicates the
number of packets
NO NO Yes None
received at the
Indicates
Ethernet port. the
number of bytes
NO NO Yes None
received at
Indicates the the
Ethernet
number ofport. CRC
error packets NO NO Yes None
received at the
Indicates
Ethernet port. the traffic
received at the NO NO Yes None
Ethernet port.
Indicates the
number of packets
NO NO Yes None
transmitted at the
Indicates
Ethernet port. the
number of bytes
NO NO Yes None
transmitted at the
Ethernet
Indicates port.the traffic
transmitted at the NO NO Yes None
Indicates
Ethernet port. the
number of IP
addresses NO NO Yes None
configuredthe
Indicates forIP the
Ethernet and
address port.mask
NO NO Yes None
list configured for
Indicates
the Ethernet the port.
negotiation mode
NO NO Yes None
configured on the
Ethernet
Indicates port.the actual
Indicates
Indicates
negotiation themode
the speed
duplex of NO NO Yes None
mode
mode of the
of
the Ethernet the port.
Ethernet
Ethernet port.port. ThisIf an
parameter must be
Ethernet electrical NO NO Yes None
set toisthe
port used,same this
value as that
parameter of the
is valid
peer port. NO NO Yes None
when SPEED is not
Indicates
set to AUTO. the If an
negotiation
Ethernet optical mode of
NO NO Yes None
the
port NE
is connecting
used,
Indicates
to the this
the Ethernet speed
port.
parameter
mode of themust NE be
set to FULL.to the NO NO Yes None
connecting
Indicates
Ethernet port. the duplex
mode
Indicates theNE
of the type NO NO Yes None
connecting
Indicates
of Ethernet the to the
trunk.
Ethernet
cabinet
If port.
number of
this parameter is
the toboard
Indicates
set where the
the
DISABLE, YES NO No LOFD-003008
Ethernet
number of
member
Indicates trunk
the of
ports
whether is
established.
subrack
the
to housing
Ethernet
enable thetrunk
ARP YES NO No LOFD-003008
the
must
proxy board
be
Indicates where
manually
the
function onthe
Ethernet
configured.
number
the Ethernettrunk In is
this
of thetrunk.slot
established.
case,
housing
If thethe board
this parameter is YES YES No LOFD-003008
configured
where
set member
the Ethernet
to ENABLE, the
Indicates
ports
trunk
BS are the the
is established.
performs
number proxythe
considered
ARP of as the
on valid YES NO No LOFD-003008
Ethernet
member
IP addresses trunk.ofofits
ports
the Ethernet
loopback trunk.
interfaces NO NO No LOFD-003008
If this
(or parameter
of the lower- is
set toBS).
level ENABLE,If this
member ports
parameter is set of to NO NO No LOFD-003008
the Ethernet
DISABLE, thetrunk
BS
must
does also be
not perform
manually
the ARP proxy on
configured.
the IP addresses In thisof
case,
its the valid
loopback
member
interfacesports (or of ofthe
the Ethernet
lower-level BS). trunk
are negotiated
The external device
Indicates the size of
the Maximum
Indicates the type
Transmission Unit
of subboard
(MTU)
Indicates theon
in the the
status
board
Ethernet
of where the
trunk. The
the Ethernet YES YES No None
Ethernet
trunk. Thetrunk
recommended stateisMTUof
established.
value is above
the Ethernet trunk 576.
NO NO No LOFD-003008
If the value
depends
Indicates theisthe
on MAC
smaller
state of than
the
address of the 576,
member
broadcast
ports.
EthernetIf the packets
state
trunk. Theof NO NO Yes LOFD-003008
such asisthe
the member
format XXXX-DHCP
ports
packet fail to be
of the existing
XXXX-XXXX. The
received
Ethernet or
trunk of is an NO NO Yes LOFD-003008
MAC address
transmitted.
Indicates
activated,
Ethernet port the
theMAC state
is that
address
of
of the ofEthernet
the Ethernet
first the
NO NO Yes LOFD-003008
Ethernet
trunkadded
port trunk
is activated.
to theat
Indicates
the peer end.the
Ethernet trunk.
number of member
NO NO Yes LOFD-003008
ports in the
Indicates the
Ethernet trunk.
number of the
NO NO Yes LOFD-003008
member port of the
Indicates the
Ethernet trunk.
number of active
NO NO Yes LOFD-003008
member ports of
Indicates
the Ethernetthe trunk.
number of an active
Indicates the of the NO NO Yes LOFD-003008
member port
number
Ethernetoftrunk.
packets
(including the
Indicates NO NO Yes LOFD-003008
discardedthe packets)
number
receivedofbybytes
the
(including the
Ethernet trunk. NO NO Yes LOFD-003008
discardedthe
Indicates bytes)
received
number ofby the
Ethernet
discardedtrunk.
packets NO NO Yes LOFD-003008
Indicates
received by thethe
number
Ethernetoftrunk.
discarded
Indicates thebytes NO NO Yes LOFD-003008
receivedofbypackets
number the
Ethernet trunk.
(including the
Indicates NO NO Yes LOFD-003008
discardedthe packets)
number of bytes
transmitted by the
(including the
Ethernet trunk. NO NO Yes LOFD-003008
discardedthe
Indicates bytes)
transmitted
number of by the
Ethernet
discardedtrunk.
packets NO NO Yes LOFD-003008
Indicates
transmitted theby the
number
Ethernetoftrunk.
discarded bytes NO NO Yes LOFD-003008
Indicates
transmitted theby the
number of IP
Ethernet trunk.
addresses NO NO Yes LOFD-003008
configured for the
Indicates
Ethernet the IP
trunk.
Indicates
address listtheof the NO NO Yes LOFD-003008
number of the
Ethernet trunk.
cabinet housing the
Indicates
board where the the YES NO No LOFD-003008
number
memberof porttheof an
subrack housing
Ethernet trunk is
the board the
Indicates
located. where the YES NO No LOFD-003008
memberof
number porttheofslot
an
Ethernetthe
housing trunk is
board
located. YES YES No LOFD-003008
where the member
Indicates
port of an the
Ethernet
number of the
trunk is located. YES NO No LOFD-003008
parent Ethernet
trunk of the port.
Indicates
Indicates the whether
number
Indicates
the member ofthethe port is YES YES No LOFD-003008
member
priority
the primary portof port
the in an of
Ethernet
member
an Ethernet trunk.
port in an
trunk.
Ethernet
Each Ethernettrunk. trunk A NO NO No LOFD-003008
smaller
has oneparameter and only
value
one primary indicates port. a
Indicates
higher the
priority. type NO YES No LOFD-003008
The primary port
of
must sub-board
be the first on the
Indicates
board where the the switch
port added to an YES YES No None
used
member to control
port of an
Ethernet
Indicates trunk
the and
status
whether
Ethernet totrunkallocate is
the lastmember
Indicates
of the portthe MAC
bandwidths
located.
Indicates the to port
removed
address
in an of
Ethernet from theperiodthe NO NO Yes LOFD-003008
transmission
mode of port
Ethernet
member
trunk. trunk. when
resource groups
transmitting on
being addedthe to an
the
LACP physical
Protocol portData NO NO Yes LOFD-003008
Ethernet trunk. The
based
Units on theirat the
format(PDUs) of the MAC
scheduling
local end.isIn weights.
long
address XXXX- NO NO Yes LOFD-003008
When
period
Indicates mode, the period the
XXXX-XXXX.
RATECFGTYPE
time
modeinterval of for
(the rate
periodically
transmitting the NO NO Yes LOFD-003008
configuration
Indicates
transmitting
LACP PDUs thethe attype)the
is set
number
LACPend.
peer to of
PDUs is received
SINGLE_RATE,
LACP
large. PDUs
Indicates the on the NO NO Yes LOFD-003008
different
memberof
number values
port of of an
this
Ethernet parameter
transmitted trunk.LACP lead
to different NO NO Yes LOFD-003008
PDUs on the
Indicates
bandwidth
member port the of an
number
allocation
Indicates
Ethernet trunk. of theID of
methods
the YES YES No None
extension
as
the follows:
transport
Indicates the user
(1)ID Ifdata
this
of
type.
parameter
the transport
Indicates theis
group set
typeto
DISABLE
related
parameter
of primary to theand
group
transport the NO YES No None
Indicates
sum
services of
related toused
resource TX the
the to
priority
service of
bandwidths
corresponding
transmit that
the theof user the
to an
service
associated
extended data, QCI. which YES YES No None
corresponds
date when hybrid to the
is identified
resource
extended
transmission groups
QCI. byisaIt
Indicates
DSCP
exceeds
uniquely value. the flow
the
identifies The a
adopted.
Indicates HQ
the rate NO YES No LBFD-00300201
control
priority
bandwidth
Indicates
transport type
of the
of for
the high-
parameter the the
indicates
configuration that mode LOFD-00301101
user
service
physical
activity data data with
port, has the
each a
group.
quality
of transport the
factor
transmission
of
LOFD-00301103
extended
positive
Indicates
resource
services QCI. Ifis
correlation
the
group NO NO No
resources
resource are used,
groups LOFD-003016
this
with
primary
allocatedparameter
the
corresponding DSCP
porta load is in
to an
while
the BS, LQ indicates
which can LOFD-001032
set
value. to
threshold
bandwidth
extended
Indicates of the
QCI. is
thethat
that
be low-quality
set toproportional
NON_FLOW_CTRL
user
directly
primary-to-data in the NO YES No LOFD-003016
transport
SINGLE_RATE resources or
,secondary
toflow
hybrid
its control
transmission
configured port is not TX
load
are used. When
DUAL_RATE. The
performed
scenario.
bandwidth;
ratio threshold A for
larger
(2) the
If
of
admission
dual rate control is NO YES No LOFD-003016
service.
value
this
the parameter
user In
indicates
data thisinisathe
performed
configuration andrefers a
case,
greater
set
hybrid to if the rate and
probability
ENABLE
transmission
new
to the service
hybrid of theis
configuration
of
the services
sum
scenario. of ATX being type
smaller NO YES No LOFD-003016
requests
peak admission,
information LOFD-00301101
dual rate,
preferentially
bandwidths
value indicates the of the a
the
rate IP
(PIR)pathand route LOFD-00301102
committed
admitted
associated
greater to the
probability
with
committedsame primary LOFD-00301103
information
primary
resource
of services path.
groupsrate
being NO YES No
transport
information resource
rate is LOFD-00301202
(CIR)
exceeds bandwidth
preferentially the
type
(CIR). willIf be used as
this LOFD-003016
used
bandwidth
admitted to transmit
toofthe the the
the primary
parameter is set to NO NO No LOFD-001032
LOFD-00301101
service
physical
primary data.
port,
path. Ifeach
this
transport
SINGLE_RATE, path. the
parameter
resource group isto is set
transmission
FLOW_CTRL,
allocated a flow NO NO No LOFD-003011
resource
control is group
bandwidth performed
that is
performs
for this service.
directly
Indicates traffic
proportional
the In
Indicates
shaping the time
based IKE
this
to its
intervalcase,
scheduling
for the on
ifsending rate NO NO No LOFD-003009
local
its name.
transmit
configuration
weight.
the keepaliveWhentype is
bandwidth.
dual rate,
RATECFGTYPE
packets. Ifthe If this
the peak
parameter NO NO No LOFD-003009
(the rate is
information
parameter israteset
set to to
DUAL_RATE,
(PIR) bandwidth
configuration
0, keepalive theis
type)
transmission
used
is set to
packets to transmit
are not the
resource
service
DUAL_RATE,
sent. group
data.
performs
different values traffic of
shaping
this parameter based lead on
PIR and
to different CIR the
transmission
allocation methods
admission algorithm
Indicates the
timeout duration for
waiting for the
keepalive packets.
NO NO No LOFD-003009
If this parameter
Indicates the is
set to 0, keepalive
Differentiated
packets
Servicesare Code not NO NO No None
sent. (DSCP) of the
Point
Indicates
ISAKMP. the
cabinet number of NO NO Yes None
the IKE local board.
Indicates the
subrack number of NO NO Yes None
the IKE local
Indicates the board.
IKE
Indicates the slot
exchange
number of mode. the IKEIn NO NO Yes None
main mode, keys
local board.
are exchanged
Indicates the name
independently from YES YES No LOFD-003009
of the IKE peer.
identity
Indicates
authentications.the ID of
the IKE
This protectsproposal in NO YES No LOFD-003009
use.
identity information
Indicates
and hencethe IKE NO NO No LOFD-003009
protocol
Indicates
enhances version.
the IP
security.
Indicates
address
In aggressive ofthethetype
peer
of
end.theWhen
mode, identification
identity the NO NO No LOFD-003009
payload
encapsulation
authenticationthat the is not
local
mode end
protected.of transmits.
the IPSec
If the
The authentication
proposal
authentication is the NO YES No LOFD-003010
can
method be performed
transmission of themode,IKE
based
the onproposal
IP address
security IP or of fullyis
qualified domain NO YES No LOFD-003011
the
set toIKE peer must
name
be the(FQDN).
same as the
PRE_SHARED_KE
Indicates
destination the IP name
IP
Y, the main
Indicates the mode
pre- NO YES No LOFD-003012
of the
address
address peerof
of end.
the
the local
ACL
does
shared not support
key. The two
end,
rule.
FQDN which
If they
whileendsis used
are
the
negotiation
in IKE negotiation.
different,
aggressive encoded
mode NO YES No LOFD-003013
must
This beaddress
IP configured can
packets
Indicates
supports.
with the will fail to
whether
same
be
be
to set to 0.0.0.0
decoded.
enable the Dead or
authenticator.
a configured NO NO No LOFD-003014
Peer Detection
interface
(DPD) function.IP address
Indicates the time
at the local end. If
after a DPD NO NO No LOFD-003015
this parameter is
detection the
Indicates succeeds.
set to 0.0.0.0,time the
interval for
BS automatically sending
NO NO No LOFD-003016
frames
Indicates
uses theforinterface
a DPD
the
detection.
number
IP address to of
retransmission
negotiate with the NO NO No LOFD-003017
Indicates
attempts the
after a IP
peer. If multiple
encryption
DPD detection
addresses are fails.
algorithm used in NO NO No LOFD-003018
configured
the IKE proposal. at the
port, it is the
Indicates
The Data
recommended
cabinet
Encryption numberthat of NO NO Yes None
you
the IKEspecify
Standard peer
(DES)one IP
board.
is
Indicates
address thethe
for
an internationally
subrack
negotiation. number of NO NO Yes None
used data If the
the
local IKEBS peer
usesboard.
the
encryption
Indicates the slot
digital
algorithm,certificate
number of which the IKE NO NO Yes None
and
uses IPa address
56-bit key. for
peer board.
authentication
The 3DESthe in
is also
Indicates
the negotiation, ID of
an internationally YES YES No LOFD-003019
the
ensureIKE proposal.
that the IP
used encryption
address
algorithm, in which
the
certificate is thekey. NO NO No LOFD-003020
uses a 168-bit
same as the local
The Advanced
IP
Encryption of the
address
BS.
Standard (AES) is
an advanced
encryption
algorithm, which
provides three
ISAKMP SA, where
Digest Algorithm 5
ISAKMP is short for
(MD5) uses a 128-
Internet Security
bit secret the
Indicates key,Diffie-
Association and
whereas
Hellman (DH)Secure
the group
Key Management
Hash
of the Algorithm
IKEand proposal.1
Protocol SA is
(SHA1)
The uses a 160-
shortcorefor security
bit secret key.
technology usedThein
association.
MD5
an IKEalgorithm
proposal is
IKE negotiation
Indicates the NO NO No LOFD-003021
supports
the faster
Diffie-Hellman
requires
authentication a long time
calculation
(DH) exchange but
to
modecalculate
used in Diffie-
the
lower security
technology. Thethan NO NO No LOFD-003022
Hellman
IKE keys.
proposal. ToDH
For
the SHA1
exchange
prevent
details,
Indicates updating
see the of
algorithm.
technology Foris used
the ISAKMP
RFC2409.
Pseudo-random SA NO NO No LOFD-003023
details,
to calculatesee private
from
Functionaffecting
(PRF)
RFC2409.
information The
based
communication
algorithm used in
AES-XCBC-MAC-
on public
security,The
IKEv2. a lifecycle
PRF NO NO No LOFD-003024
96 algorithmItisis
information.
longer
algorithm than 10
used only is
mathematically in used
IKEv2. to
minutes
generate isthe
For
provendetails
that about NO NO No LOFD-003025
recommended
materials
Indicates required
the for
this algorithm,
decrypting the see
DH
the
for ISAKMP
IKE
cabinet number of SA.
RFC3566.
information is and
Before
the board thethat
authentication lifecycle NO NO Yes None
impractical
of an
IndicatesSA due
For to
elapses,
encryption.
adopts thethe IKE
calculation
two
subrackends
details about will
number howofto
security proposal.
complexity.
negotiate
the board with
that
generate materials, each NO NO Yes None
Indicates
otherRFC4306.
adopts tothe the
generate
IKE slot a
see
number
new
securitySA to of the
replace
proposal.
Indicates
board thatthe adopts NO NO Yes None
the
numberoriginalof the one.
the
The IKE
new security
SA is used
cabinet
Indicates
proposal. housing
the the
upon the MRFD-231501
board
number where
of the a YES NO No
completion of the LOFD-003002
transmission
subrack thatand the
negotiation,
resource group is
houses
Indicates
original the
SA the board
is MRFD-231501
established. YES NO No
where
number a
removedofonce the slot
its LOFD-003002
transmission
corresponding
lifecycle elapses. to
resource MRFD-231501
the boardgroup whereisa YES YES No
established. LOFD-003002
transmission
Indicates
resource group the ID isof a
MRFD-231501
transmission
established. YES NO No
LOFD-003002
resource
Indicates group. the
destination
Indicates the IP MRFD-231501
YES YES No
addressmask
subnet of passing-of the LOFD-003002
by traffic. IP
destination
MRFD-231501
address of the YES YES No
LOFD-003002
service traffic bound
Indicates
to a transmissionthe bearer
type of
Indicates transmission
resource group. the type YES NO No None
resource
of sub-board group. on the
board where a
YES YES No None
transmission
Indicates the type
resource
of port where group a is
established.
transmission
Indicates the YES YES No None
resourceofgroup
number the port is
carried.a
where
YES NO No None
transmission
resource group is
Indicates
carried. the ID of YES YES No LOFD-003011
an IP path.
Indicates the
cabinet number of
NO NO No None
the board where the
Indicates
IP path is the located.
subrack number of
NO NO No None
the board where the
Indicates
IP path is the slot
located.
number of the
NO YES No None
board where the IP
path is located.
Indicates the
physical port type of NO YES No LOFD-003011
the IP path.
Indicates the type
of the IP path. QOS
indicates that this IP
path is used to
Indicates
carry the
the service
number
with of
specified
Indicates the theID of
NO NO No LOFD-003011
physical
Quality ofport
the adjacent node Serviceof the
IP
for path.
(QoS),
the that
signaling is, with to
Indicates the local
a specified
Indicates
which the the
IP address of an IPIPDSCP.
path NO YES No LOFD-003011
ANY
belongs.
path. indicates
Differentiated
ThisIf IP the that IP
this
path
addressIP
Services Path
is used Code
must can
forbean be a
used to carry NO YES No LOFD-003011
Point
S1
valid (DSCP)
interface,
one of class of the
this A,
services
services
parameter
B, or C but of must
any
carried
must on benot
QoS
an
be IP
set toand
the
Indicates path.
the hence
ID of
reserved
the type is
the NO YES No LOFD-003011
used
S1
Indicates
address to
interface
of transport carry
whether
0.x.x.x the
that or
service
Indicates
connects
to enable
127.x.x.x.
resource without
the
the
the
If this
for peer
PING
the aIP
specified
IP address
eNodeB
detection
parameter
path. ThetotoDSCP.
of
the
is
value the
check
setHQ toIP NO YES No LOFD-003011
path.
MME.
the Note
IP path.
0.0.0.0,
indicates this
high-that
The
IP in
S1-flex
PING
address
quality scenarios,
detection
needs to
transport is
NO YES No LOFD-003011
this
used
be parameter
to check
negotiated.
resources, and the can
the
be setLQ
connectivity
value to the of
indicatesIDan of IP
the S1If interface
path.
low-quality PINGto
the transport NO NO No LOFD-003011
any MME.isIfThis
detection
resources. the IP
Indicates
path
disabledis used
parameter must the
in the for an be
application
X2 interface,
firewall
set in the locatedtype this inof NO YES No LOFD-003011
IP
the path.
parameter
transport
hybridtransmission must be
set to theorIn
network
scenario. IDinother
ofthe the
NO NO No LOFD-003011
X2
CN interface
equipment,
scenarios, the thata
Indicates
connects
detection the
the
failure actual will
default value of this
real-time
eNodeB
be resulted, traffic
to thewhich
parameter is used. NO NO Yes None
transmitted
corresponding
will causethe theonre- the
Indicates
IP path. actual
neighboring
establishment
real-time trafficof
eNodeB.
the S1 interface NO NO Yes None
received on the IP
and
path.disrupt
Indicates theservices
actual
in the cell.
non-real-time traffic
NO NO Yes None
Therefore, this
transmitted on the
Indicates
path. the
parameter
IP must actualbe
non-real-time
set to DISABLE traffic
Indicates thethe actual NO NO Yes None
received
under such on IP
TX
path. bandwidth
scenarios.
reserved for the
Indicates the actual NO NO Yes None
non-real-time
RX bandwidth
service transmitted
reserved
on the IP for path. the
NO NO Yes None
non-real-time
service
Indicates received
the Pingon
the IP path.
check result of the NO NO Yes None
Indicates
IP path. the ID of
the transmission
resource group NO YES No None
established
Indicates theon an
IP path.
description about
Indicates whether NO NO No None
the
the peer
IP path of the
joins IP
Indicates
path. the typea
transmission
of sub-board on the
resource group. NO YES No None
board where the IfIP
this
path parameter
is established. is
Indicates
set to DISABLE, the the
source NO NO No None
IP path IP is address
of an IP pathon
established route.
the
The source
default transmission IP
Indicates the type YES YES No LOFD-003016
address
resource must
group beon
Indicates
of
the transport
same the
as the
a specific physical
destination IP on
resource
configured carried
device YES YES No LOFD-003016
port.
address
IP address. IP
an IP path of an
route.
path value
The route.HQ
indicates high- NO YES No LOFD-003016
quality transport
resources, and the
value LQ indicates
low-quality transport
resources.
Indicates the next
hop IP address of
an IP path route.
The next hop IP
address and the
configured device NO YES No LOFD-003016
IP addressthe
Indicates must be
Indicates
on the same the local
ID of
IP address
Indicates
an IP PM theof peer
session an IPof YES YES No LOFD-00301201
network
PMaddress
session. segment,
IP
an NE. ofThisthe IP IP
but cannot
address be the
excluding
PM session.
Indicates that the IP
This
same.
0.0.0.0 must be NO YES No LOFD-00301201
address must
activation direction be a
configured
valid IP addressat theof
of the IP PM
Ethernet
Class A, B, port, C
session. Fororthis NO YES No LOFD-00301201
Ethernet
Indicates trunk,
and different or
parameter to from
the be
loopback
any existing
Differentiated interface.
IP
valid, the peer must
address
Indicates
Services
also support ofthe
Codethe the local
round-IP NO YES No LOFD-00301201
end.
trip
Point
PM In
delay addition,
(DSCP)
session. calculated
Ifof it
an
this
cannot
by an IPbe
IP PM session.
parameter PM set to
is set to
0.x.x.x NO NO No LOFD-00301201
UP, theor
session 127.x.x.x.
detection.
IP PM
The
sessionround-trip
initiated by
delay
the BSisisthe time
activated. NO NO Yes None
that
If thisisparameter
consumedisto
Indicates
transmit IPthePM DL
set
jittertocalculated
BIDIR, thebyIP
detection
PM sessions packets to NO NO Yes None
an
and IPfroPM sessionthe
between
initiated
Indicates
detection. bythe BSUL and
local
the peer
jitter andare
calculated peer by
ends. NO NO Yes None
activated.
an IP PM the
Indicates session DL
detection.
byte loss rate
calculated
Indicates by an IP
whether NO NO Yes None
Indicates
PM session the UL
to
bytebindloss therate IP PM
detection.
session to an IP IP
calculated by an NO NO Yes None
path.
PM session PM
If the IP
Indicates
session
detection. isthe
bound UL to
Indicates
activation
an IP path, the
status
the typeIPof NO NO Yes None
of
PM session uses A
an IP
IP PM
PM session.
session.
Indicates
triplet
the localconsiststhe DL
and of
peer
activation
local IPstatus
theaddress
IP of theofIP NO NO Yes None
an
path IPinPM
address, data session.
peer IP
address,
transmission. If and
NO NO No None
protocol
TXBWASW type; ora
quadbit consists
RXBWASW of the of
the local IP
algorithm of a NO NO No None
address,
transmission
Indicates peer
the ID IPof
address,
resource
the IP path protocol
groupto which is
type,
set IPtoand DSCP.
ON session
and this is NO YES No None
an PM
Indicates
bound. whether
parameter is also
the
set toDSCP ON, value the of NO NO Yes None
a DL IP dynamically
system PM session
changes.
adjust bandwidth
Indicates the initialof
the transmission
DSCP value of a DL NO NO Yes None
resource
IP PM session.
Indicates group
the
associated
modified DSCP with the
IP pathofaccording to NO NO Yes None
value a DL IP PM
Indicates
the IP PMthe
session. time
detection
when
result.the DSCP NO NO Yes None
value of an IP PM
Indicates
session changes. the
cabinet number of
YES NO No None
the board where the
Indicates
IP route isthe located.
subrack number of
YES NO No None
the board where the
Indicates
IP route isthe slot
located.
number of the
YES YES No None
board where the IP
route is located.
Indicates the type
of sub-board on the
Indicates the type YES YES No None
board where the IP
of route. If this
route is established.
parameter
Indicates the is set
typeto
Indicates YES NO No None
of port. thealltype
NEXTHOP, the
of
IP routing
packetstable that for a
Indicates
static
meet the the port
IP route.
route A YES NO No None
number.
static
directionhostare route
firstis a
manually
forwarded to the
configured
specified next route hop YES YES No None
whose
IP subnet
Indicates theIf this
address. mask
is 255.255.255.255.
parameter
destination IP to is set
A
IF,static
all thegateway YES YES No None
address
Indicates ofIP
the packets
the
route
that
route. is a manually
meet the route
subnet mask for the
configured
direction are route
first
destination IP YES YES No None
whose
forwarded subnetthe mask
address of to the
is not
specified
Indicates egress
the IP
route.
255.255.255.255
port.
address
Indicatesofthe the next YES NO No None
and
hop.whose
priority of the next
hop
routingIP address
table entry. and
egress port IP NO NO No None
A smaller parameter
address
value denotes are ona
different network
higher priority. NO NO Yes None
segments. A
Indicates
dynamic host the route
description
is a dynamically of the
NO NO No None
destination
acquired route of the
route.
whose subnet mask
Indicates the type
is 255.255.255.255. NO NO Yes None
of the port.
A dynamic gateway
route is a the port
Indicates
NO NO Yes None
dynamically
number.
Indicates the
acquirednumber
cabinet route of
whose
the portsubnet
to which mask YES NO No None
Indicates
is
thenotIPSecthe policy
subrack
group is number
bound. of
255.255.255.255
the
andportwhose to which
next YES NO No None
Indicates
the
hopIPSec the
IP address slot
policy and
number
egress port IP port
group is of the
bound.
to which are
Indicates
address the
theonIPSec
type YES YES No None
policy
of group
sub-board
different network ison the
bound.
board
segments. with the port
YES YES No None
to which the IPSec
Indicates
policy group theistype
of port
bound. to which the
YES YES No LOFD-003018
IPSec
Indicates policythe group
is bound.of the port
number
to which the IPSec YES YES No LOFD-003018
policy group is
Indicates
bound. the name
of the IPSec policy NO YES No LOFD-003018
group.
Indicates the name
of the IPSec
Indicates the policy YES YES No LOFD-003018
group.
sequence No. of
the IPSec policy
YES YES No LOFD-003018
group. The smaller
the number,
Indicates thethe ID of
higher
the accesspriority.
the control NO YES No LOFD-003018
list.
Indicates the name
of the IPSec NO YES No LOFD-003018
proposal.
can be accessed
through the key.
The elements used
to generate keys
are not reusable.
Indicates the If
a key is
lifetime of an IPSec
compromised,
Indicates
SA. Whenthe thisname other
keys are
configuration
of the IKE peer
parameter still mode
valuethat
secure.
of the lifetime of an NO YES No LOFD-003018
is referenced
reaches a specified by the
When
IPSecthe
time, the
SA.
policy. IPSec
IPSecThe SA
launches
value not
does GLOBAL a
take NO NO No LOFD-003018
negotiation
indicates
effect. Beforetheusing global
the
this security
lifetime
SA becomes of thepolicy, IPSec
Indicates the traffic
a
SA,PFS and
invalid, the is the value
IPSec NO NO No LOFD-003018
volume threshold
exchanged.
LOCAL
policy indicates If the a
for theestablishes
IPSec policy,
PFS
the
new is
local assigned
SAwhich lifetime of
through to
above
Indicates the NO NO No LOFD-003018
the
the local
IPSec SA.
negotiation. end, the
BeforeIfa this
negotiation
encapsulation for
PFS exchange
parameter isSA set is
the negotiation
new
mode IPSec
of an IPSec isisto
required
GLOBAL,
complete, when the
thevalue 0 the
started.
proposal, The which NO NO No None
negotiation
validity
Indicates
original
indicates period
SA the
that
is used
is ofcan
the the
be set
launched
IPSec
cabinet
to protect to
SA TUNNEL
at
numberis the
3600. of
function,
or TRANSPORT. which In
peer
the end. The
board
communication. that DH NO NO Yes None
initiates
Indicates
TRANSPORT negotiation
the
group
adopts
After assigned
the
the IPSec IPSec to
for
mode,a new
subrack number
only data SA
of
is
the local
policy.
negotiation end and
is traffic
based
the board
encrypted. on the
that
In NO NO Yes None
peer
Indicates
complete,end must
the
the be
new
volume,
adopts
TUNNEL ismode,
the disabled.
IPSec
the same.
Indicates
security
SA is the
protocol
immediately slotthe
policy.
whole
used in toIPan
Otherwise,
number
used ofpacket
protect the is
the
IPSec
NO NO Yes None
protected,
negotiation
board
proposal. that
communication. Theandfails.
adopts a
value
new
AH IP header
Theindicates
the security
IPSec
Indicates policy.
the level
the
name is of
Indicates
added
the to
1024-bit
Authentication the
the Diffie-
of the IPSec YES YES No LOFD-003018
authentication
original
Hellman
Header IPgroup
(AH) packet. (Dh-
proposal.
algorithm
The
group2)source
protocol is used IP in in
higher
specified
the
thanAH.
address
RFC2402.thatThe and
ofThe thethe NO NO No LOFD-003018
Message-Digest
destination
768-bitESP
value Diffie- IP
indicates
Algorithm
address
Hellman
the Encapsulatingof 5the
group (MD5) new
(Dh-
algorithm
IP uses a NO NO No LOFD-003018
Security Payload IP
header
group1). are
However, the
128-bit
addresses secret
longer protocol
(ESP) processingof two key,
whereas
ends
time isofrequired
specified thethe Secure
in security by NO NO No LOFD-003018
Hash
tunnel. Algorithm
the Dh-group2.
RFC2406. Both The the1
Indicates
(SHA1) uses the a 160-
TRANSPORT
value AH_ESP mode
authentication
bit secret key. The
and the
indicates TUNNEL
that NO NO No LOFD-003018
algorithm
MD5 algorithm usedthe in
modeprotocol
ESP
Indicates are the used is for
the ESP.
features faster
end-to-end IPSec
preferentially
encryption used
calculation
protection. but in
The NO NO No LOFD-003018
to protect
algorithm
Indicates the packets,
used
lower
TUNNEL
but not
the ESP. security
the mode,AH than
cabinet number of
the SHA1
however,
protocol. is also
the board that NO NO Yes None
algorithm.
applied
Indicates tothe the
adopts the IPSec
protection
proposal. of a of
subrack number
certain
the board segment.
that NO NO Yes None
adopts
Indicates thethe IPSec slot
proposal.
number of the
NO NO Yes None
board that adopts
Indicates
the IPSecwhether proposal.
to enable the local
NO NO Yes None
maintenance
Indicates the
Ethernet layer
physical port.
status
Indicates of the the local NO NO Yes None
maintenance
number of error
Ethernetthat
packets port.are
NO NO Yes None
received at
Indicates the the local
maintenance
number of packets
Ethernet
received
Indicates at port.
the the local NO NO Yes None
maintenance
number of error
Ethernetthat
packets port.are
NO NO Yes None
transmitted
Indicates theat the
local maintenance
number of packets
Ethernet port.
transmitted at the NO NO Yes None
local maintenance
Ethernet port.
127.x.x.x.
2. This IP address
must be different
from the IP address
of the remote
maintenance
channel and
Indicates the the
device IP
subnet maskaddress.
of a NO NO No None
3. This
local IP address
maintenance
must
channel.be on Thisdifferent
network segments
subnet mask must NO NO No None
as
be the IP address
a valid
Indicates mask of
the
the remote
address
cabinet numberand cannot
of
maintenance
be 0.0.0.0 or YES NO No None
the board where the
channel
Indicates and
255.255.255.255.
port the the
is located.
device IPnumber
subrack address. of
YES NO No None
4. This
the board IP address
where the
Indicates
mustisbe
port the slot
different
located.
number
from other the
of
YES YES No None
board
configuredwhere the
device
port
IP is located.
addresses.
Indicates the port LOFD-00301101
5. This IP address YES YES No
type. LOFD-00301102
and the destination
IP addressthe
Indicates of port
the IP LOFD-00301101
route must be on YES YES No
number. LOFD-00301102
different
Indicatesnetworkthe switch
segments. LOFD-00301101
for limitingthe
Indicates theUL line NO NO No
LOFD-00301102
rate at the port.
committed
information rate LOFD-00301101
NO YES No
after rate limitation
Indicates the LOFD-00301102
is configured
Committed at a
Burst
port. LOFD-00301101
Size (CBS) after NO YES No
Indicates the is LOFD-00301102
rate limitation
Excess
configured Burstat aSize
port. LOFD-00301101
(EBS) after rate NO YES No
LOFD-00301102
limitation is
Indicates the type
configured
of sub-board at on
a port.
the
Indicates the aDL YES YES No None
board where port
committed
is located.
information rate LOFD-00301101
NO YES No
after rate limitation
Indicates the LOFD-00301102
is configured
number of theat a
port.
cabinet where the YES NO No None
Indicates
MLPPP group the is
number
located. of the
subrack where the YES NO No None
MLPPP group
Indicates the is
located. ofwhether
Indicates
number the slot
an MLPPP group YES YES No None
where the MLPPP
supports the
the multi-
group is located.
Indicates
class
number feature.
of the YES YES No LBFD-00300403
If this
MLPPP parameter
group. is
set to ENABLE, the
LBFD-003004
MLPPP group NO NO No
LBFD-00300403
supports
Indicates the the Class
of Service
authentication (CoS) type
feature and four or NO NO No LBFD-00300403
of the MLPPP
Indicates
eight service
group.
Indicates the
the types
local
authentication
of different
IP address. If this user
NO YES No LBFD-00300403
name of
priorities. an
parameter is set toMLPPP
group.
Indicates
0.0.0.0, this theIP
authentication
address needs to NO YES No LBFD-00300403
password.
be negotiated. If
this parameter
Indicates the is NO NO No LBFD-00300403
not set to
subnet mask0.0.0.0,
of theit
must IP
local beaddress.
set to a If
validparameter
this IP addressisof NO NO No LBFD-00300403
class
set to A, B, or Cit but
0.0.0.0,
must
needs to be
not be the
reserved address
negotiated.
0.x.x.x or 127.x.x.x.
Indicates the peer
IP address. When
the eNodeB is
connected to a peer
equipment, the peer
IP address can be
either user-
NO NO No LBFD-00300403
specified or set to
0.0.0.0.
IndicatesIf the
this
parameter
MP/MC head is set to
option NO NO No LBFD-00300403
0.0.0.0,
of the this
MLPPP.
Indicates whetherIP
address
to enableisPPP obtained
by means of NO NO No LBFD-00300403
multi-frame
negotiation.
multiplexing.
Indicates the
fragment size of an NO NO No LBFD-00300403
MLPPP
Indicatesgroup.
the
maximum
Indicates the length of LBFD-003004
NO NO No
the PPP MUX
timeout duration of LBFD-00300402
Indicates
subframe. the
a PPP MUX
maximum length of LBFD-003004
combination. NO NO No
the PPP MUXIf the LBFD-00300402
PPP
frame. MUX
combination takes LBFD-003004
NO NO No
longer time than LBFD-00300402
this parameter
Indicates the
value, LBFD-003004
numberanofalarmMC NO NO No
related to 4the LBFD-00300403
priorities: or PPP
8.
Indicates whether
MUX combination
to enable
timeout is IP header
reported. NO NO No LBFD-003004
Indicates
compression.the
threshold above
which the MLPPP NO NO No LBFD-00300401
Indicates
packet loss thealarm is
threshold
generated.below
which the MLPPP NO NO No LBFD-00300403
packet loss alarm is
Indicates
cleared. the status
of an MLPPP NO NO Yes None
group.
Indicates the status
of the IPCP NO NO Yes None
protocol.
Indicates the status
NO NO Yes None
of the PPP MUX.
Indicates the
negotiation result of
NO NO Yes None
the local IP
address.
Indicates the
negotiation result of NO NO Yes None
the local IP
Indicates themask.
negotiation result of
NO NO Yes None
the peer IP
address.
Indicates the
negotiation result of NO NO Yes None
the multi-class
Indicates the PPP.
negotiation result of
NO NO Yes None
the maximum RX
unit.
Indicates the
negotiation result of NO NO Yes None
the PPP MUX.
Indicates the
negotiation result of
NO NO Yes None
the address field
Indicates
and control thefield.
negotiation result of
NO NO Yes None
the protocol field
compression.
Indicates the
negotiation result of NO NO Yes None
the IPHC.
Indicates the
number of packets NO NO Yes None
received.
Indicates the
number of packets NO NO Yes None
sent.
Indicates the RX
NO NO Yes None
traffic.
Indicates the TX
NO NO Yes None
traffic.
Indicates the
number of IP
NO NO Yes None
addresses of an
MLPPP
Indicatesgroup.
the list of
IP addresses of an NO NO Yes None
Indicates
MLPPP group. the type
of sub-board on the
board where an YES YES No None
MLPPP group is
Indicates
established. the
number of bytes NO NO Yes None
received.
Indicates the
number of
NO NO Yes None
discarded packets
Indicates
received. the
number of
NO NO Yes None
discarded bytes
received.
Indicates the
number of bytes NO NO Yes None
transmitted.
Indicates the
number of
NO NO Yes None
discarded packets
Indicates
transmitted. the
number of
NO NO Yes None
discardedthe
Indicates bytes
transmitted.
number of the
cabinet where the YES NO No None
Indicates
MLPPP sublinkthe is
number
located. of the
subrack where the YES NO No None
MLPPP sublink
Indicates the is
located. of the slot
number
YES YES No None
where the MLPPP
sublink is the
Indicates located.
number of the YES NO No LBFD-00300403
MLPPP sublink.
Indicates the
Indicates
number ofthe the NO NO No LBFD-00300403
number
MLPPP group.of the
subrack housing
Indicates
the board the where the NO NO No LBFD-00300403
number
E1/T1 port of slot
carrying
Indicates
holding theboard
the
the MLPPP sublink
number
where theof E1/T1
the NO YES No LBFD-00300403
is located.
E1/T1
port slotthe
carrying
Indicates carrying
the
the
MLPPPMLPPP
number of the is sublink.
sublink
Timeslot
located. 0 cannot NO NO No LBFD-00300403
E1/T1 port carrying
be
the configured.
MLPPP In
sublink.
Indicates
E1 mode,the timeslot 1
Maximum Receive NO YES No LBFD-00300403
to 31 can be
Unit (MRU).
configured. In The T1
received
mode, only packet
NO NO No LBFD-00300403
whose
timeslots length
1 to 24 is
greater than
can be configured. this
parameter
Other timeslots valueare is
discarded.
not used.
Indicates whether
to enable protocol NO NO No LBFD-003004
Indicates whether
field compression.
to enable the
compression of the NO NO No LBFD-003004
address
Indicatesfield
the and
control field.
timeout duration of
NO NO No LBFD-00300403
the MLPPP sublink
Indicates
negotiation. the type
of sub-board where
YES YES No None
an MLPPP sublink
Indicates the type
is established.
of sub-board where
NO YES No None
an MLPPP group is
established.
Indicates the status
of the MLPPP NO NO Yes None
sublink.
Indicates the status
of the Link Control
NO NO Yes None
Protocol (LCP)
Indicates
protocol. the
negotiation result of
NO NO Yes None
the maximum RX
Indicates
unit. the
negotiation result of
Indicates thefield NO NO Yes None
the protocol
negotiation
compression. result of
the Address-And-
Indicates the type NO NO Yes None
Control-Field-
of
Compressionon the
sub-board
board
(ACFC). where the
NO YES No None
E1/T1 port carrying
the MLPPP
Indicates thesublink
is located.
number of packets NO NO Yes None
received.
Indicates the
number of bytes NO NO Yes None
received.
Indicates the
number of
NO NO Yes None
discarded packets
Indicates
received. the
number of
NO NO Yes None
discarded bytes
received.
Indicates the
number of packets NO NO Yes None
transmitted.
Indicates the
number of bytes NO NO Yes None
transmitted.
Indicates
Indicates thethe peer
number
IP address of of the
NO NO Yes None
discarded
connectivity packets
Indicates
transmitted. the
detection
number ofof the
remote NO NO Yes None
discarded
Indicates the bytes
maintenance
transmitted.
master/slave flag of
channel. The BS
the remote YES YES No None
performs
Indicates PING
the localfrom
maintenance
the
IP local IP of
address address
the
channel.
to the peer IP
remote NO YES No None
Indicates
address
maintenance ofthe
thelocal
subnet
remote
channel. mask of a
remote
maintenance NO YES No None
maintenance
channel. In general,
channel.
the peer IP address
NO YES No None
is set to the IP
address of the
M2000; but when
the BS cannot
directly connect to
the M2000 by
performing PING,
for example, a
Indicates whether
Indicates
to add a route the peer for
subnet
the remote mask of a
remote
Indicates the
maintenance NO YES No None
maintenance
cabinet
channel.number If this of
channel.
the
parameterwhere
board is set to the
Indicates the NO NO No None
remote
YES, one route is
subrack
maintenance number of
automatically added
the board
channel is where
located. the
to the
Indicates remote NO NO No None
remote the slot
maintenance
number of the
maintenance
channel
board whereaccording the
channel is located. NO YES No None
to the parameters
remote
Indicates
configured
maintenance the bybearer
the
Indicates
type
user. of
If a
this the
remote
channel is located. NO NO No None
destination
maintenance
parameter isIPset to
address
NO, you must in the
channel. used
routing
manually table
add for a NO NO No LBFD-004002
Indicates
remote the one
route
subnet to a remote
mask of the
maintenance
maintenance
destination
Indicates
channel. the
This IPtype
IP NO YES No LBFD-004002
channel
address when
used the
in the
of route in
address is the
a
peer
routing IP address
table for of
a
routing
Network table
ID, whichfor a
the
remoteremote NO YES No LBFD-004002
remote
is usually the
maintenance
maintenance
maintenance
address of the
channel
Indicates
channel, and
the the
that is,the
the
channel.
network where
device
priority
destination IP
of address
the route
network NO NO No None
If this parameter
M2000 is located. is
are
added notfor
segment onwhere
athe same
remote the
set to NEXTHOP,
network
maintenance
EMSnext segment
is located.
the
Indicates hop
the IP next NO NO No None
and the network
channel.
address
hop IP must
address beof
segment
A smaller in of the
parameter
specified
the route the
device
value IP added
indicatesaddress for
routing
a remote table. a NO YES No None
does
higher not cover that
priority.
Indicates
maintenance
of the peer the IPstatus
of a remote
channel.
address. NO NO Yes None
maintenance
Indicates whether
channel.
the remote
Indicates
maintenance the type NO NO Yes None
of sub-board
channel is being on the
board
used. where a
remote NO YES No None
Indicates
maintenance the
cabinet
channelnumber is of
the board
established. where the YES NO No LOFD-00301401
Indicates
packet filtering the is
subrack
used. number of
the board where the YES NO No LOFD-00301401
Indicates
packet filtering the slot is
number
used. of the
board where the YES YES No LOFD-00301401
packet filtering is
used.
Indicates the type
YES YES No LOFD-00301401
of the port.
Indicates the
Indicates whether
sequence
to permit
Indicates the ornumber
reject
port
of the Access
access of the data YES YES No LOFD-00301401
number.
Control
that does Listnot(ACL).
match
The BS currently
the ACL rule. If this NO YES No LOFD-00301401
supports only
parameter is set to
advancedaccess
PERMIT, ACLs. of
ACLsthat
data 3000 does throughnot NO NO No LOFD-003014
3999
matchare
Indicates theadvanced
ACL
the rule
type
ACLs.
is allowed.
of sub-board If this
on the
parameter is set to YES YES No None
board where packet
Indicates
DENY, data
filter is enabled.the that
number
does notofmatch the NO NO Yes LOFD-00301401
transmitted
ACL rule is
packets.
discarded.
Indicates the
number of received NO NO Yes LOFD-00301401
packets.
Indicates the
number of
NO NO Yes LOFD-00301401
permitted packets
Indicates
on the TXthe channel.
number of
NO NO Yes LOFD-00301401
permitted packets
Indicates
on the RXthe channel.
number of rejected
NO NO Yes LOFD-00301401
packets on the TX
Indicates
channel. the
number of rejected
NO NO Yes LOFD-00301401
packets on
Indicates the the RX
channel.
number of bytes
contained in NO NO Yes LOFD-003014
transmitted
Indicates the
packets.
number of bytes
NO NO Yes LOFD-003014
contained
Indicates
Indicates the in
the
received
number of
number ofpackets.
bytes
bytes
contained in
contained in the NO NO Yes LOFD-003014
Indicates
permitted the
packets
packets that match
number
on the TXof channel.
bytes
the defaultthe
Indicates ACL
contained in NO NO Yes LOFD-003014
rule. If MB the
Indicates is set to
permittedofthe
number packets
PERMIT,
number
packets ofthis
that bytes
match
on the RX channel.
parameter
contained
the defaultinACL NO NO Yes LOFD-003014
Indicates
measures
rejected
rule. If MB the
the
packets
is set to on
number
number of bytes
ofthis
the TX channel.
PERMIT, bytes
contained
contained in
parameter in the NO NO Yes LOFD-003014
rejected
accessed
measures packets
packets
the on
the
that RX channel.
match
number of the
NO NO Yes LOFD-003014
default
accessed
Indicates ACL rule. If
packets
the
MB
that is set
match
destination IP to DENY,
the
this
defaultparameter
address in a pingIf
ACL rule. NO NO Yes LOFD-003014
measures
MB isentry.
filter set to the DENY,
This
number
this
address of
parameter bytes
Indicates the be a
must
YES YES No LOFD-003014
contained
measures
valid IPmask in
thethe of
address
subnet
discarded
number of packets
class A, B, or C.toIt
corresponding
that
can match
discarded
also be the
packets
the IP
Indicates
default thea
address
ACL rule.
in a YES YES No LOFD-003014
that
networkmatch the
segment
ping filterofentry. The
number
This parameter the
default
subnet ACL
address. mask rule.is
cabinet
valid that
only the houses
when is
This parameter
Indicates
cannot be where
0.0.0.0. YES NO No None
the board
CATALOG is set to
valid
number only ofwhen
the
port
PORT. security is
CATALOG
subrack that is set to
enabled.
Indicates theboard YES NO No None
PORT. the
houses
number
where port of the slot
security
corresponding
is enabled. to
YES YES No None
the board where
Indicates
port security the istype
of sub-board
enabled. on the
YES YES No None
board where port
Indicates
security isthe type
enabled.
of port on which
Indicates whether YES NO No LOFD-003014
port security
Indicates
to disable the is
services
enabled.
number
on a specified port
of the port
on which port port
to implement YES YES No LOFD-003014
security is
security. If this
configured.is set to
parameter
NO NO No LOFD-003014
DISABLE, running
Indicates
services on thethe port
cabinet number
is prohibited, of
YES NO No None
the board where the
thereby
PPP link is located.
guaranteeing the
security of the port.
Indicates the mode
in which the local
end of a PPP link
authenticates the
peer end. The
authentication
Indicates the
mode is classified
subrack
into NONAUTH,number of
YES NO No None
the board
PAP, and CHAP.where In the
Indicates
PPP link isthe slot
located.
PAP mode, user
number of the
names and YES YES No None
board where the
passwords are
PPP link isthe
Indicates located.
transmitted
number
explicitly ofon the PPP YES YES No None
Indicates
link. thethe
network.
number ofIf the they are
intercepted
ET/T1 port that during NO YES No None
transmission,
carries the PPP a
great
link. threat to
network security
Indicates the is NO NO No None
caused. of
number
Indicates Thus,
the the
the
PAP is timeslot
ET/T1 applied user
authentication only
that
to the of
carries network
the NO YES No None
name thePPP PPP
Indicates
environment
link. Timeslot the with0 is
passwordfor for
low security
used NO YES No None
authenticating
requirements. With
synchronization, a
PPP
and link.
threecannot
handshakes,be
the CHAPthe
configured.
Indicates provides
Inlocal
E1 NO YES No None
a
IP more
mode,
address.secure
timeslots If this 1
Indicates
authentication. the peer In
to 31
parametercan beisIfset
Indicates
IP
CHAPaddress.
mode,
the theto
only NO NO No None
configured.
0.0.0.0,
subnet this Inof T1
BS
user connectedthe
mask
isaccounts to
mode,
parameter
local only
IP address. Ifto
needs
an upper-level
rather than
timeslots
be
thisnegotiated.
Indicates 1 to 24
node,
passwords thiswhether
parameter address
arePPP
is NO NO No None
can
to
set be0.0.0.0,
enable
to configured.
the it
is specified
transmitted,
Other
multiframe
needs timeslots
to be are
according
enhancing to the
security
not used.
multiplexing
negotiated. NO NO No None
upper-level
comparedIf to node.
the If
function.
the BS is this
cascaded
PAP.
parameter is set to LBFD-003004
to a lower-level NO NO No
ENABLE,
node, thisthemultiple
address LBFD-00300402
Indicates
PPP frames are
must
maximum be specified.
length of LBFD-003004
multiplexed
This parameter on the
can NO NO No
the PPP
PPP link MUX
to reduce LBFD-00300402
be set to 0.0.0.0.
Indicates
subframe. the
the bandwidth
maximum length of LBFD-003004
overhead. NO NO No
the PPP MUX LBFD-00300402
Indicates
frame. the
timeout duration of LBFD-003004
NO NO No
the PPP MUX LBFD-00300402
combination.
Indicates the
Indicates whether
LBFD-003004
to enable IP
Maximum header
Receive NO NO No
LBFD-00300401
compression.
Unit (MRU). If the
size of a received
NO NO No None
packet is greater
than the MRU
Indicates whether
value,
to enable the protocol
packet is NO NO No LBFD-003004
Indicates
discarded.
field whether
compression.
to enable the
compression of the NO NO No LBFD-003004
address field
Indicates the and
control field.
timeout duration for
NO NO No None
the PPP link
negotiation.
Indicates the status
NO NO Yes None
of the PPP link.
Indicates the status
of the Link Control
NO NO Yes None
Protocol (LCP)
protocol.
Indicates the status
of the IP Control NO NO Yes None
Protocol (IPCP).
Indicates the status
NO NO Yes None
of the PPP MUX.
Indicates the local
IP address
NO NO Yes None
negotiated
Indicates the with the
mask
peer
of theend.
local IP
address that is NO NO Yes None
negotiatedthe
Indicates with the
peer
peer
IP end.
address
NO NO Yes None
negotiated with the
Indicates
peer end. the
negotiation result of
Indicates the NO NO Yes None
the IP header
negotiation
compression. result of
the compression
NO NO Yes None
switch
Indicates of the
the
address fieldresult
negotiation and of
control
the field.
compression NO NO Yes None
switch of the
Indicates the
protocol field.
negotiation result of
NO NO Yes None
the maximum RX
unit.
Indicates the
negotiation result of NO NO Yes None
the PPP MUX.
Indicates the
number of packets
NO NO Yes None
received on the
Indicates
PPP link. the
number of packets
NO NO Yes None
transmitted on the
PPP link. the RX
Indicates
traffic of the PPP NO NO Yes None
link.
Indicates the TX
traffic of the PPP NO NO Yes None
link.
Indicates the
number of IP
NO NO Yes None
addresses of the
PPP link. the list of
Indicates
IP addresses of the NO NO Yes None
Indicates
PPP link. the PPP
frame error rate
threshold above NO NO No None
Indicates
which the the PPP
related
frame
alarm is error rate
generated.
threshold below NO NO No None
which the the
Indicates related
type
alarm
of is cleared.
sub-board on the
YES YES No None
board where a PPP
Indicates the
link is located.
number of bytes
NO NO Yes None
received
Indicates on thethe
PPP link.
number of
discarded packets NO NO Yes None
Indicates
received on thethe
number
PPP link. of
discarded bytes NO NO Yes None
received on
Indicates thethe
PPP link.of bytes
number
NO NO Yes None
transmitted
Indicates theon the
PPP link.of
number
discarded packets NO NO Yes None
transmitted on the
PPP link.
Indicates the
Indicates the lowest
number
priority ofofqueue 0.
discarded bytes
If the Differentiated NO NO Yes None
transmitted
Indicates theonlowest
Services Code the
PPP
Point link.
priority of queue the
(DSCP) of 1. NO NO No LBFD-00300201
service
If the DSCP packet is
of the
Indicates
greater packet
service thanthethis
lowest
is
priority
parameter
less of
than PRI0queue
value, 2.
but NO NO No LBFD-00300201
If
thethe DSCP
priority
greater than isof the
Indicates
service thethis
packet lowest
is 0.
mapped
parameter to value,
queue
priority
less than of queue
PRI1 3.
but NO NO No LBFD-00300201
the
If thepriority
DSCP isof the
greater
mapped than
tothe this
queue
Indicates
service
parameter packet
value, is 1.
lowest
priority
less of
than PRI2queue 4.
but NO NO No LBFD-00300201
the
If thepriority
DSCP isof the
greater
mapped than
tothe this
queue
Indicates
service
parameter packet
value, is 2.
lowest
priority
less of
than PRI3queue 5.
but NO NO No LBFD-00300201
the
If thepriority
IndicatesDSCP isoflowest
the the
greater
mapped than
toqueue this
queue
priority
service
parameter
of
packet
value, is 6.3.
If the
less DSCP
than PRI4 valuebut NO NO No LBFD-00300201
the
of apriority
service ispacket
greater
mapped than this
is smallertothan
parameter
queue
value, PRI5 4.
Indicates
but greater thethan or NO NO No LBFD-00300201
the
numberpriority is
equal
mapped to of
this
to
the
queue 5.
cabinet
Indicates
parameter thatthe houses
value,
the
the board
numberserviceofwhere
the
packet a YES NO No None
transmission
subrack that
is mapped to queue
resource
houses
6.
Indicates thegroup
theboard is
established. YES NO No None
where a
number of the slot
transmission to
corresponding
resource
the boardgroup whereisa YES YES No None
established.
transmission
Indicates the bearer
resource
type of a group is
Indicates
established. the type YES YES No LOFD-003011
transmission
of sub-board
resource group. on the
board where a
YES YES No None
transmission
Indicates the type
resource
of port where group a is
established.
transmission
Indicates the YES YES No LOFD-003011
resource
number ofgroup the portis
carried.
where a
YES NO No LOFD-003011
transmission
Indicates the
resource
Indicates group
maximum
Indicates ID isof a
uplink
the
the rate
carried.
bandwidth
of the TXa
transmission
unit of YES YES No LOFD-003011
transmission
resource
bandwidth, group.
RX
resource
bandwidth, group at
TX CIR,
the MACTX layer NO YES No LOFD-003011
RX CIR, PIR
when
and RX thePIR of the
transmission
transmission NO YES No LOFD-003011
resource
resource group
group. is
Indicates
carried over theIP.RXThis
bandwidth
parameter value of a is
NO YES No LOFD-003011
transmission
Indicates
used as the theuplink
TX
resource
transport group.
committed burst
admission
size of a and TX
bandwidth NO YES No LOFD-003011
transmission
traffic shaping
Indicates the TX
resource
bandwidth.
excessive group.
burst size
Indicates the NO YES No LOFD-003011
of a transmission
Indicates
scheduling the index
weight
resource
of a
of the group.This
operator.
transmission
parametergroup.
resource is used NO NO No LOFD-003011
to
Thisdifferentiate
parameter is
between operators.
used in calculating
NO NO No LOFD-003011
the bandwidth
scheduled to a
resource group,
which helps
achieve the user
admission control.
Indicates the
transmit CIR of the
NO YES No LOFD-003011
transmission
Indicates
resource group.the
receive CIR of the
NO YES No LOFD-003011
transmission
Indicates
resource group.the
transmit PIR of the
NO YES No LOFD-003011
transmission
Indicates
resource group.the
receive
Indicates theoflocal
PIR the
NO YES No LOFD-003011
transmission
Indicates traffic
real-time the size thatof
resource
the group.
peak burst
is transmitted in a
Indicates
transmitted
transmission thefrom
local the NO YES No None
real-time
transmission
resource traffic
group.that
is received
resource
The local group.in a
traffic
Indicates
transmission the local NO NO Yes None
includes
non-real-timeonly the traffic
resource
local trafficgroup.
stream
that
The is transmitted
local thetraffic
exclusive
Indicates
in of the
a transmission local NO NO Yes None
includes
passing-by
non-real-timeonly the
datatraffic
resource
local trafficgroup.
stream
flow
that
The and
is non-traffic
received
local traffic in a
exclusive
stream.
transmission of the NO NO Yes None
includes
passing-by only the
data
resource
local trafficgroup.
stream
flow
The and non-traffic
local traffic
exclusive
stream.
Indicates of the
the TX NO NO Yes None
includes only
passing-by the
data
bandwidth
local traffic reserved
stream
flow
for and non-traffic
non-real-time
exclusive
stream.
Indicates of the NO NO Yes None
services
passing-by inthe RX
adata
bandwidth
transmission reserved
flow
for and non-traffic
non-real-time
resource
stream. group. NO NO Yes None
services in a
Indicates
transmission the GBR
service traffic
resource group. that is
NO NO Yes None
transmitted by the
Indicates
resource group.the GBR
service traffic
NO NO Yes None
received by the
Indicates
resource group.the rate
configuration mode
NO NO Yes None
of the resource
Indicates the uplink
group.
admission
bandwidth of the NO NO Yes None
Indicates
transmission the
downlink admission
resource group.
bandwidth of the NO NO Yes None
transmission
Indicates the UL
resource
CIR admission group.
NO NO Yes None
bandwidth of the
Indicates
resource group.the CIR
admission
NO NO Yes None
bandwidth of the
Indicates
logical port thein UL
DL.
PIR admission
NO NO Yes None
bandwidth of the
Indicates
resource group.the PIR
admission
Indicates the NO NO Yes None
bandwidth
number of the
of the
logical
cabinet port
that
Indicates the inhouses
DL. LOFD-00301101
the
number of the a
board where YES NO No LOFD-00301102
transmission
subrack that LOFD-00301103
resource
Indicates group
houses the theboard is
established. YES NO No None
where a of the slot
number
transmission to
corresponding LOFD-00301101
resource
the boardgroup whereisa YES YES No LOFD-00301102
established.
transmission LOFD-00301103
resource group is
occupied.
Indicates the type
Indicates
of sub-board
Indicates whether
whether on the
Indicates
to
boardenable where whether
the a
to
to enable
enableadjustment traffic
the YES YES No None
dynamic
transmission
Indicates
shaping whether
thea type
for
backpressure
of the
resource TX bandwidth
to
of enable
port
transmission
algorithm ongroup the
which
of a a
is
of a transmission
established.
dynamic
transmission
resource adjustment
group. YES YES No LOFD-003011
Indicates
transmission the
resource
of the parameter
resource
If this RX group.
group isis
number
resource of the port
group.
If this
bandwidth
carried.
set to parameter
ON, of
traffic a is
on which
The BS a
monitors
set to
transmission
shaping ON, the TX YES NO No LOFD-003011
data is
transmission
the
bandwidth buffered
is in
resource
performed
Indicates
resource group.
whether
group isof a
Indicates
the queues
Indicates
adjusted the
the of
according IDeach
rate LOFD-00301101
If this parameter
according
backpressure
carried. to the is TX is
transmission
downsizing
to the network packet YES YES No LOFD-00301102
set to
bandwidth
performed ON, the
so that
on RX
the
resource
loss group.
group,
rate threshold
performance andin a LOFD-00301103
bandwidth
the
OM transmit
FTP queue istraffic LOFD-00301101
determines
for
dynamicbandwidth whether
adjusted
would
transmission
the notbandwidth
transmission
according
exceed NO NO No LOFD-00301102
adjustment.
adjustment
to the network When
the capability
resource
resource group.
group of isIf LOFD-00301103
RXBWASW
parameters
Indicates
performance the or
(down
and LOFD-00301101
downstream
this parameter
congested, and is
TXBWASW
speed
number
dynamic PLR of is set to
Priority
bandwidth NO NO No LOFD-00301102
routers,
set to
transmits thus
ENABLE, the the
ON,
threshold
Queues the estimatedand down LOFD-00301103
IndicatesFTP(PQs)
adjustment
avoiding
OM
backpressure queue
the
in a
LOFD-00301101
available
speed
transmission
parameters delay transport
(down
unnecessary
participates
threshold
signals for
(number the packet
delay NO NO No LOFD-00301102
bandwidth
threshold).
resource
speed PLR is
The
group.
loss
decision
due
and and
to rate
congestion of the LOFD-00301103
reduced
network
The
thresholdqueues ifand
theindown a
congestion.
congestion
downsizing.
status of the status
Whenof LOFD-00301101
packet
performance
transmission
speed loss
delay rate
is
If
thethis
RXBWASW parameter
transmission
transmission or isIP NO NO No LOFD-00301102
detected
Indicates
monitored
resource
threshold). through
thethrough
groupThe are
set
TXBWASWto OFF,
resource
resource group,
group)traffic
is settoto LOFD-00301103
Performance
number
IP PM
classified
network threshold
sessions,
into PQs of LOFD-00301101
shaping
and
ON,
each the
the
flow OMis not
estimated low-
control
Monitoring
discarded
which
and can
non-PQs.
performance (IP
packets.
be is PM)
The NO NO No LOFD-00301102
performed
level
available
service.
Indicates upload during
transport
the and
is
Thishigher
enabled
scheduling
monitored parameter than
at the
priority
through this
local LOFD-00301103
data
download
bandwidth
If the
congestion transmission.
number data
istime of
threshold.
indicates
end
of
IP any
PM or at
PQ
sessions,If
theis the
peer
higher
preempts
reduced
data
threshold packets the
ifthe
the
of a indelaythe NO NO No LOFD-00301102
packet
Indicates
capability
end.
than
which that loss
can of
of be rate
the
any
bandwidth
jitter
buffer detected
transmission of any of non-
by an
detected
congestion
queue
If this
non-PQ.
enabled in through
a
parameter
There
at clear
the local is isIP
real-time
IP PM
backpressure
resource sessionservices.
group. is a If
PM
time
no
end is
to lower
threshold
transmission
set OFF,
Priority
or this than
the
Queues
at the peer of
TX
this
above
queue
When parameter
exceeds
TCSW isset
isthe NO NO No LOFD-003011
this threshold,
transmission
resource
bandwidth
when
end. this group
is not tothe
set
to to
threshold.
75% DISABLE,
ofpackets.
ENABLE, the queue
if the
estimated
resource
buffer
adjusted.
parameter
If this parameter available
group.
value A is LOFD-00301101
OM
capacity,
buffer FTP time queue
the of BSnon-
transport
When
greater
0.The
Indicates
set to TCSW
OFF, bandwidth
parameter
queues the the TXis RXset NO NO No LOFD-00301102
does
regards
real-time notthis participate
service
is
to increased.
valueENABLE,
numbered
bandwidth indicates is ifof
from
reserved
not thea0 to LOFD-00301103
the decision
transmission
data in a the
buffer
stronger
the
for result time
signaling
adjusted. status of of
capability.
after or non-
this
OM
congestion
resource group
transmission
real-time
If this
parameter
data.
the parameter
This
transmission valueas
service is NO NO No LOFD-00301102
congested
resource
data
set
minus to
parameter in0,
1 a the
are and
group queue
PQs.
should
resource
transmits
exceeds group,
the
transmission
in
PQ
be aset transmission
scheduling
toOM a value is
and the
congestion
threshold, low-
itsignals. NO NO No LOFD-00301102
resource
used
smaller between
thangroup the PQs.isTX
level
If the
indicates
Indicates upload
number that
the andof
the
below
cannot
A smaller
bandwidth the
buffer PQ of a
download
data packets data
transmission
reserved
threshold,
packets,
number
transmission RX
andit in
indicates thus the a NO NO No LOFD-003011
does
buffers
resource
bandwidth, not of preempt
all
group which is
indicates
all
higherthe
resource delayed that
scheduling
group. the
the bandwidth
backpressure
congested
should be and ofthe
transmission
packets
priority.
The onset
The
recommended
non-real-time the to
queues TX a
queues
backpressure
value
resource
channel
numbered
reserved TX is
smaller less
group
are from than
than is
this NO NO No LOFD-003011
services.
50%
signals
or equal of arethetoThe queue
the RX
not congested
discarded.
parameter
bandwidth The
value
is lowerand to
bandwidth
capacity,
transmitted.
bandwidth the of
of OM
BS
a
therefore
number
6 are
than non-PQs.
or equalthe to 3%
threshold of
low-level
does
transmissionnot upload the
regard NO NO No LOFD-003011
congestion
discarded
Weight
of the TX Round clear
packets
bandwidth
and download
transmission
resource group. data
signals
determines
Robin
of are
(WPR)
a transmission
Indicates thethe
is far
resource smaller group than as
transmitted.
maximum
scheduling
resource
number amount
ofgroup.is used
the YES YES No None
that
congestedof any other
and
of datalink.
between
SCTP
service. thatnon-PQs.can be
therefore
buffered inwould
Indicates the a not
transmitnumber
cabinet
transmission congestion of NO NO No None
release
the SCTP
resource signals.
link.
group.
Indicates the
The congestion
subrack number of NO NO No None
time threshold of a
the SCTP link.
transmission
Indicates the slot
resource
number ofgroup the NO YES No None
determines
SCTP
Indicates link. the the
Indicates
amount of thedata first that
maximum
local IP stream
address of
is buffered when NO NO No None
number
an SCTP oflink.
the It
the
SCTP transmission
link.
must
resource be agroup
valid IP is
address
congested. class of Ensure A, NO NO No None
B,
that the maximumnot
or C but must
be
amountthe reservedof data that
address
can be buffered 0.x.x.x or is
127.x.x.x.
not less than the
amount of data that
is buffered during
congestion.
alpha value of an
SCTP link. This
Indicates
parameterthe RTO
second
beta
computes value local of IP
the anvalue
address
SCTP link.
of the Smoothed of the
This
SCTP
parameter
Round-Trip link. ItTime must
be a
computes valid
(SRTT) for a value IP
the
address
of the Smoothed
specific of Class A,
destination
B, or
Round-TripC,
address; A largerbut it
Time NO NO No None
cannot
(SRTT)
Indicates
value be
for
of this set
the a to
first
Indicates
0.x.x.x
specific or the
127.x.x.x.
destination local
peer
parameter
port IP address
number indicates
of the of NO YES No None
The
address;
anhighervalueimportance
SCTP
Indicates
a Athe0.0.0.0
larger
link. It
SCTP
indicates link.
Indicates
value
must
to thebe
minimum of
last athat
thisthe
valid
RTT the IP
second
parameter
address of class
Retransmission
measurement. local
peer IP
indicates ForA, NO NO No None
address
a
B,higher
or C but
Timeout
definitions is
of invalid.
an
importance
(RTO) ofmust the not
SCTP
to
bethe
value
alphathefor link.
last
reserved
value, the It see
RTT must
SCTP
be a valid
measurement.
address
link.
RFC4960.A smaller IP
0.x.x.xvalue For
or NO NO No None
address
definitions
127.x.x.x.
of this of
parameter
RTO Calculation: class
of the A,
Indicates
B,
betaor C
value, but the must
see peer not
indicates
The
port rules agoverning
number shorter
of the NO YES No None
be
time
the the
RFC4960. reserved
required
computation to of
SCTP
address
RTO link.127.x.x.x.
checkCalculation:
SRTT,
Indicates link
RTTVAR, the
The rules are
connectivity.
and RTO governing
The
as NO NO No None
maximum
Indicates RTO
the
the
time computation
follows: required to of
value
heartbeat of an SCTP
interval
SRTT,
Indicates
check
1) Until RTTVAR,
linkan theRTT initial
link.an
for A SCTP
larger value
and
RTO RTO
value areislink.as NO NO No None
connectivity
measurement
indicates
The heartbeat a of longerantwice
has
follows:
SCTP
the sum link. A larger
been
period
check
1) Until isan RTTnew
made of
required thefor afor
value
RTO
packet
checking indicates
and sent heartbeat
link to a
the
independently
measurement has NO NO No None
longer
interval.
given period
The
destination
connectivity. new
initiated
been made by each for a
required
RTO
transport ranges for
address, from
end
packet of an
sent to the
checking
the
set minimum
RTO link
to the RTO NO NO No None
association
given destination and
connectivity.
value
protocol to maximum
parameter
then
Indicates
transportconfirmed the by
address,
RTO
the peervalue.
'RTO.Initial'.
Indicates the
end
maximum
set RTO to number
the NO NO No None
2) When
maximum
through the
the number
HBfirst
of retransmissions
protocol parameter
RTT
of
ACK measurement
retransmissions
for the SCTP When
packet.
'RTO.Initial'.
R
no isservices
over made,
a path.set When
are NO NO No None
association.
2) When theRTTVAR When
first
SRTT
the number
carried, = aR, link of
the
RTT number
measurement of
= R/2, and RTO
retransmissions
disconnection =
retransmissions
R is made,
SRTT + 4 * setis for NO NO No None
over a
determined
the path
association if the
SRTT
RTTVAR. = R, RTTVAR
exceeds
number
exceeds ofthe
theRTO value
value
=
3) R/2,
When and awhether
new RTT =
of this
heartbeat
Indicates parameter,
of this +parameter, check
SRTT
measurement 4 * R' NO NO No None
the
to
the path
SCTPis
attempts
switch
RTTVAR. backregarded
reaches
link to is
is
Indicates
made,
as failed set ifwhether
RTTVAR
no
the
broken
3) maximum
primary
When and a new path
a linkRTT
to
= calculate
(1
heartbeat- itRTO.Beta) the *
retransmission
when
failure
measurement is restored.
alarm is R' is NO NO No None
checksum
RTTVAR
Indicates
acknowledgment + of
whether the is
attempts
The SCTP
reported.
made, on an
link is
data
RTO.Beta toset bethe RTTVAR
If*sent.
|SRTT
to check
received.
association
switched
= (1 - to
RTO.Beta)
multiple
but
the the* -
R'|, SRTT
checksum
paths
HB ACK
secondary arepacket =of
used, is(1
the - NO NO No None
RTTVAR
RTO.Alpha)
packet that + path is*from
SRTT
path
Indicates
not
when switching
received
the the
primary is
RTO.Beta
+ RTO.Alpha
received.
number of * |SRTT * R'. -
automatically
checksum
the peer
path cannot end. be
R'|,
Note: SRTT
heartbeats The = to be- of
value (1 NO NO No None
performed.
calculation
reached. If this
RTO.Alpha)
SRTT used * SRTT
detected
algorithm.
parameter
+ RTO.Alpha isinset
before thethe
* R'.to
update
transmission
ENABLE, to RTTVAR
the SCTP NO NO No None
Note:
is Theback
itsisvalue
switches value
before totoof
link
SRTT switched
used in the
updating
the
the primary
primary SRTT path.
path
update
itself
After using
the toprimary
RTTVAR
the NO NO No None
when
is its the
value primary
before
second
path
path is assignment.
is restored,
restored. the
updating
After the
transmission SRTT If
Indicates
this parameter
Indicates
itself using the
the status
thecause is
computation,
switches back to the NO NO Yes None
of
set
of the
to
the
second SCTP
DISABLE,
latest
assignment. link.
change
update
the
SCTP primary RTO
link ispath =
not
that
After the
the operational
SRTT
when
Indicates
switched +
thethe4 *
number
the
to the time of
state of
computation, SCTP NO NO Yes None
RTTVAR.
heartbeats
of the
primary latest
path detected
change
when
link
update transitsRTO from
=
reaches
that
the thispath
the operational
primary
available value. is
SRTT + 4to *
state
restored. of the SCTP
unavailable. NO NO Yes None
RTTVAR. the
Indicates
link transits from
number
availableofto
outbound
unavailable. streams NO NO Yes None
negotiated
Indicates the for the
SCTP link.
number of inbound
NO NO Yes None
streams negotiated
for the SCTP link.
Indicates the time
interval
Indicates that
theone
end of anaddress
working SCPT link
has to wait before it NO NO Yes None
flag of the SCTP
can
link. send an
Indicates whether SACK
message in
the SCTP link is NO NO No None
response
blocked ortonot. the
reception of data. A
larger value of this NO NO No None
parameterthe
Indicates indicates
a longer time
description about
Indicates
interval the
between switch NO NO No None
the upper layer NE
that
the is used
reception
of an SCTP link. to of
control
data and
Indicates whether
the
the to
Indicates the switch NO NO No LOFD-00301101
apply
sending
activity UL admission
of the
factortoof the
that is used
control to a with
corresponding
service data
control
resource whether
group. to
SACKClass
QoS message.Indicator NO NO No LOFD-00301101
apply DL admission
(QCI)
controlofto1.aThe LOFD-00301101
activity
resource factor
group. must LOFD-00301103
NO NO No
be set for the LOFD-003016
Indicates
service with theeach LOFD-00301101
LOFD-001032
activity
QCI, becauseof the
factor LOFD-00301103
NO NO No
service
services data
ofthe of QCI
different LOFD-003016
Indicates
2. LOFD-00301101
LOFD-001032
QCIs
activityexperience
factor of the LOFD-00301103
different loads. NO NO No
service data of QCI LOFD-003016
Indicates
3. the LOFD-00301101
LOFD-001032
activity factor of the LOFD-00301103
NO NO No
service data of QCI LOFD-003016
Indicates
4. the LOFD-00301101
LOFD-001032
activity factor of the LOFD-00301103
NO NO No
service data of QCI LOFD-003016
Indicates
5. the LOFD-00301101
LOFD-001032
activity factor of the LOFD-00301103
NO NO No
service data of QCI LOFD-003016
Indicates
6. the LOFD-00301101
LOFD-001032
activity factor of the LOFD-00301103
NO NO No
service data of QCI LOFD-003016
Indicates
7. the LOFD-00301101
LOFD-001032
activity factor of the LOFD-00301103
NO NO No
service
Indicates data
the of QCI LOFD-003016
Indicates
8. the UL LOFD-00301101
LOFD-001032
admission
activity factor threshold
of the LOFD-00301103
for handed-over NO NO No
service
Indicates Adata
the of
DLQCI LOFD-003016
services.
9. larger LOFD-001032
admission
value of this threshold
for handed-over NO NO No LOFD-00301101
parameter
Indicates theindicates
UL
services.
a higher A
UL larger
admission
value of this threshold
admission success
for new Gold-level NO NO No LOFD-00301101
parameter
rate of
Indicates indicates
handed-over
the DL
services.
a higher A
DL large
services.
admission
value of this threshold
admission
for success
new Gold-level NO NO No LOFD-00301101
parameter
rate of
Indicates willUL
handed-over
the result
services.
in a high A large
UL
services.
admission
value of this threshold
admission
for success
new Silver-level NO NO No LOFD-00301101
parameter
rate of new
Indicates thewill
Gold-
DLresult
services.
in a high A
DL large
level
value services.
admissionof this threshold
admission
for new success
Silver-level NO NO No LOFD-00301101
parameter
rate of
Indicates new thewill
Gold-
ULresult
services.
in a high A large
UL
level
value services.
admissionof this threshold
admission
for new Copper- success NO NO No LOFD-00301101
parameter
rate of
Indicates new thewill result
Silver-
DL
level
in a services.
high DL A
level
large services.
admission
value threshold
of this
admission
for new Copper- success NO NO No LOFD-00301101
parameter
rate of new will
Silver-
level
resultsservices.
in a high A UL
level
large services.
value of this
admission success NO NO No LOFD-00301101
parameter
rate of newwill result
Copper-
in a high DL
level services.
admission success
rate of new Copper-
level services.
control whether tois
If this parameter
enable
set to ON, the the DL UL pre-
emption
pre-emption algorithm.
Indicates the uplink
If this parameter
algorithm is is
transport admission
set
enabled.to ON,Inthe this DL
threshold for the
pre-emption
Indicates
case, the the service DLBit
Guaranteed the
algorithm
admission
with isthreshold
Ratea(GBR) higher priority
service.
enabled.
for
that the In this
guaranteed
requests
A large value of this NO NO No LOFD-00301101
case,
bit rate
admission the(GBR) service
parameter may pre-
will result
with
service.
empt athehigher
A large
resources priority
in a high UL
that
value
of requests
of this
admitted services NO NO No LOFD-00301101
admission success
admission
parameter
with lower may pre-
will result
priorities
rate of GBR
empt
in a
Indicates
when the
high
UL resources
DL
the switch
services. NO NO No LOFD-00102901
of
that admitted
admission is usedsuccess
transmission services
to
with
rate of
control
bandwidth lowerGBR
whether priorities
is to
Indicates
when
services.
enable DL ULtheIf switch
insufficient. this NO NO No LOFD-00102901
that is used to
transmission
overbooking
parameter
Indicates the is setswitchto
control
bandwidth
admission whether is pre-to It
control.
OFF,isthe
that used UL to
enable
insufficient.
is DL
used whether If this is
toalgorithm NO NO No LOFD-00301101
emption
control to
overbooking
parameter
determine
Indicates the isthis
the set
switchto
disabled.
apply UL In
admission
admission
OFF,
admission
that the
isservices
used DL control.
to withIt
pre-
case,
control to a physical
is used
emption
bandwidth
control toalgorithm
whether of thethat to is NO NO No LOFD-00301101
higher
port. If priorities
this
determine
disabled.
resource
apply DL In the
group this
admission and
request admission
parameter is set to
admission
case,
facilitate
control services
to admission
a physical with
cannot
ON, UL pre-empt
admission NO NO No LOFD-00301101
bandwidth
higher
control.
port. If priorities
this of thethat
the
control resources
is group
appliedand of to
resource
request
parameter admission
isport.
set toIf
admitted
the physical services
facilitate
cannot
ON, DL admission
pre-empt
admission NO NO No LOFD-00301101
with lower
this parameter prioritiesis LOFD-00301101
control.
the
control resources
is applied of
when
set to
Indicates
UL
OFF, the ULtypeto LOFD-00301102
admitted
the physical
transmission services port. Ifis LOFD-00301103
admission
of flow control control for NO NO No
with
this
bandwidth lower
parameter priorities
is is LOFD-00301101
LOFD-00301202
not
user applied
data type to the 5.
when
set to
insufficient.DL
OFF, DL LOFD-00301102
LOFD-003016
physical port.
Indicates the type
transmission
admission control LOFD-00301103
Indicates
of flow
bandwidth
the
control isto thefor is NO NO No LOFD-001032
LOFD-00301101
not
thresholdapplied for LOFD-00301202
user data
insufficient. type 6. LOFD-00301102
physical port.
Indicates
entering theUL
the type LOFD-003016
Indicates the LOFD-00301103
LOFD-001032
of flow
high loadcontrolstate.for If NO NO No LOFD-00301101
threshold LOFD-00301202
userratio
the dataoffor typethe 7. UL LOFD-00301102
Indicates
entering theDL
the type LOFD-003016
transport
Indicates load
the to the LOFD-00301103
of
high flow loadcontrolstate. for
If NO NO No LOFD-001032
LOFD-00301101
UL transport
threshold LOFD-00301202
user
the
bandwidth dataoffor
ratio typethethe
of 8.
DL LOFD-00301102
Indicates
leaving the the ULtype high LOFD-003016
transport
BS keeps
Indicates load
above
the to the LOFD-00301103
of
load flow control
state. If thefor NO NO No LOFD-001032
DL
this transport
threshold for LOFD-00301202
threshold
user
ratio
bandwidth data
of thefortypeULthe
of 9. a
time-to-trigger,
leaving
Indicates the the DL the
high LOFD-003016
transport
BS keeps load
above to the
UL
load transport
threshold state. forIf load
the of NO NO No LOFD-001032
LOFD-001032
UL
this transport
threshold for
the
ratioBS
entering
bandwidth of enters
thetheof DL UL thea
the
time-to-trigger,
Indicates
high
transport loadload the
state.
load the
to the
medium
BS keeps below state.
DL transport
threshold
When
DL in
transport ULfor load
high of NO NO No LOFD-001032
If thethreshold
this ratio of the for UL
a
the
entering
load
bandwidthBS enters
state, the the
of DLtothe
BS
transport
hysteresis,
high load
load thethe
state. ULthe
medium
sends a load
UL S1 state.
BS
UL keeps
transport
transport
When in DL
below
load highofTNLthe NO NO No LOFD-001032
If
Load
this thethreshold
Indicates
bandwidth ratio
Indicator,
theof
of the for DL
the a
BS
load enters
state, the
the BS
transport
which
hysteresis,
threshold
BS is above is set load
for to
thethisto
DLthe
medium
sends atheload
DL S1
DL transport
HighLoad,
transport
leaving
threshold
state.When load
andto
UL ofTNL
ineach
UL the NO NO No LOFD-001032
Load
Indicates
bandwidth
neighboring
BS
medium Indicator,
enters the
load of
the BSthe
state.
below
medium than load state,
which
threshold
BS
through
medium
If the is the
is ratio
above setfor
load ofX2to
this
state.
the UL
TRMULLDRTRGTH
the BS sends a UL
HighLoad,
leaving
threshold
interface.
When
transport inthe DLand
loadto
DLeach to the NO NO No LOFD-001032
,S1 theTNL UL transport
Load
neighboring
medium
below load BSstate.
medium
UL ofthan
loadtransport
Indicator, theload
whichBSstate, isDL
through
If the ratio
TRMDLLDRTRGTH
the the
BSMediumLoad,
bandwidth sends of X2the
of the a DL
enters
set to
Indicates the themedium UL NO NO No LOFD-001032
,interface.
transport
S1
BStheTNL
load DL
isstate.
below load
transport
Load Whenthisto the
in
to
Over
DL each Load
transportneighboring
Control
load of
Indicator,
threshold,
UL medium the whichBS
the load UL is
BS
(OLC) through
bandwidth algorithm ofthe the X2
enters
set
Indicates theload
to MediumLoad,
transport medium of the NO NO No LOFD-001032
state,
interface.
switch.
BS is
theIn the
below
BS
thethis switch
sends
case
load
to
BS
for
a ULeach state.
enters
the S1DL TNL When
neighboring
the
OLC lowin
Load
of enabled
threshold, switch,
the DL in
DL
BS
load medium
through
state.
algorithm.
Indicator, load
whichofX2
the
When
If this is
the bandwidth
transport load of tothe NO NO No LOFD-001032
state,
interface.
UL
set low
parameter
to the BS
loadisstate,
MediumLoad, sends
set
the
BS services
enters the withlow
a
the
ON,
to DL BS
each S1 TNL
sends
bandwidth
neighboring Load
a of
UL
low
load priority
state. would
When
Indicator,
S1
the
BS TNL
services
through which
Load of
the a isin
X2
be
DL released
low load to
state, NO NO No LOFD-00301103
set
low to
Indicator, MediumLoad,
priority
interface. the QoS whichis is
guarantee
the BSLowLoad,
sends a DL
to each
set to neighboring
released
of
S1 the
TNL
to
services
Load ofto
BS
each through
guarantee neighboring thetheQoS X2 NO NO No LOFD-00301103
high priority
Indicator, which when isa
interface.
BS
of through
the services the of X2
the
set TXLowLoad,
to bandwidth
interface.
high
changes priority whento
or during
each
transport neighboring
bandwidth
the
BS overloadthe X2
through
changes
caused byorreal-time
interface.
overload
services. occurs
due to increased
load of non-flow
control services.
Indicates the
threshold for
triggering the UL
OLC. When the
Indicates
bandwidththe
threshold
occupancyforof UL
clearing LOFD-00301103
services the reaches UL NO NO No
Overload Control LOFD-001032
this threshold, low-
(OLC).
priority When
Indicates
Indicates the the
the
bearers are LOFD-00301103
bandwidth
release
removed to
threshold bearerfor NO NO No
LOFD-001032
occupancy
number
guarantee
triggering inthe of DL
one
the ULOLC
QoS
services
action
of the When
OLC. is
period.
services below
the This
of a
this threshold,
Indicates the NO NO No LOFD-00301103
number
high is
priority.
bandwidth
Indicates the
theno traffic
bearers
threshold
number
occupancy are
of for
bearers
ofofDL
type.
longer Traffic
removed. LOFD-00301103
clearing
released
services the
in an
reaches DLOLC NO NO No
different
Indicates types
the is
mode LOFD-001032
Overload
action
this period.
threshold, Control
transmitted
of the ping by low-
filtering.
(OLC).
priority When
bearers theare
different
When
Indicates the VLANs.
whitelist
the VLAN LOFD-00301103
bandwidth
removed to NO NO No
Other
is used, data only refers to LOFD-001032
group
occupancy
guarantee
that ofthe
the
the DL
QoS
the data
network
added VLANexcept
segments the
services
of the is below
services of a
user
or data,
hosts
mapping specified
belongs NO NO No LOFD-003014
this
high threshold,
priority.
signaling,
by the
to. Multipleping high-
filter
bearers areVLAN no
priority
can
groups ping OM
are data,
theused NE. in
longer removed. YES YES No None
and
the scenario in OM
When low-priority
the blacklist
Indicates
data.
is used, whether
Low-priority
the network
which telecom
to
segments priority
OM set the
data includes
or hosts of
operators share YES YES No LBFD-003003
a
thesingle
data VLAN.
of the If a
File
transport
Indicates resources
the VLAN
special
Transfer VLAN
Protocol
and
mode. use
Indicates If different
this
the DSCP
mapping
(FTP) is
service.User not YES NO No LBFD-003003
VLAN
parameter policies. is
priority
required,
data of ituser
includes is set data.
IP to
SINGLEVLAN,
recommended
Indicates
CLOCK the VLAN it
that
indicates
the
ID that
service.Used thethat
parameter servicethe
be
High- NO YES No LBFD-003003
Indicates
configured the VLAN
set
data
priority OM VLAN
tobelongs
DISABLE. datato. In ID
priority.
and
this VLAN
case, A greater
priority
the
includes the data of
parameter
can
defaultbe VLAN
directly valueused NO NO No LBFD-003003
NTP/SNTP, remote
denotes
to label
Indicates
mapping a
the higher
the VLAN
is used. next
maintenance
priority.
tag.
hop
The IP address
default
channel switchover, YES YES No None
If thisTCP
used
mapping
Indicates
and parameter
for mapping
between
the
(excluding is
set
the
DSCPs
subnetto
VLAN. and
mask
that related to FTP). of the
VLANGROUP,
priorities
next hop is IP address it YES NO No None
indicates
described
used for mapping that
as the
next
follows:hop IP
the VLAN.
addresses
If the DSCPare is NO YES No LBFD-003003
mapped
within thetorange the
VLAN
from 0 groups,
Indicates to 7, thethen and
VLAN
then mapped to the NO YES No LBFD-003003
ID indefault
the the VLAN priority tag.
VLAN
is 0; tags in the
Indicates
VLAN
If the DSCPgroups theisVLAN
NO NO No LBFD-003003
priority.
according
within the range to the
DSCPs
from of
8 to 15, the IP
Indicates the thenVLAN
packets.
the default In priority NO YES No LBFD-003003
group number.
VLANGROUP
is 1;
mode,
If the DSCP ensure is that
the VLAN groups NO NO No None
within the range
are
fromconfigured.
16 to 23, then
Otherwise,
the default priority the
configuration
is 2; does
not
If thetakeDSCP effect. is
within the range
from 24 to 31, then
the default priority
is 3;
If the DSCP is
within the range
from 32 to 39, then
the default priority
is 4;
If the DSCP is
within the range
from 40 to 47, then
the default priority
is 5;
If the DSCP is
within the range
from 48 to 55, then
Enumeration
Feature Name Value Type GUI Value Range Unit
Number/Bit
Remote Electrical
Interval values 0~29 Not involved None
Tilt Control
Remote Electrical
Character string 0~2 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~17 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~49 characters Not involved None
Tilt Control
Remote Electrical
Interval values 0~62 Not involved None
Tilt Control
Remote Electrical
Interval values 4~5,60~254 Not involved None
Tilt Control
Remote Electrical
Interval values 0~5 Not involved None
Tilt Control
AISG1.1~1,
Remote Electrical AISG1.1, AISG2.0, AISG2.0~2,
Enumeration values None
Tilt Control 3GPP, UNKNOWN 3GPP~3,
UNKNOWN~255
Remote Electrical
Interval values 0~8 Not involved None
Tilt Control
Remote Electrical
Character string 0~19 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~127 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~19 characters Not involved None
Tilt Control
SINGLE_RET~1,
Remote Electrical SINGLE_RET,
Enumeration values STMA~2, None
Tilt Control STMA, MULTI_RET
MULTI_RET~17
Remote Electrical
Character string 0~2 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~17 characters Not involved None
Tilt Control
Remote Electrical SINGLE_RET, SINGLE_RET~1,
Enumeration values None
Tilt Control MULTI_RET MULTI_RET~17
Remote Electrical SINGLE~1,
Enumeration values SINGLE, DUAL None
Tilt Control DUAL~2
Remote Electrical REGULAR, REGULAR~1,
Enumeration values None
Tilt Control DAISY_CHAIN DAISY_CHAIN~2
Remote Electrical
Interval values 1~8 Not involved None
Tilt Control
Remote Electrical
Interval values 0~29 Not involved None
Tilt Control
Remote Electrical
Character string 0~2 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~17 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~49 characters Not involved None
Tilt Control
Remote Electrical
Interval values 0~62 Not involved None
Tilt Control
Remote Electrical
Interval values 4~5,60~254 Not involved None
Tilt Control
Remote Electrical
Interval values 0~5 Not involved None
Tilt Control
AISG1.1~1,
Remote Electrical AISG1.1, AISG2.0, AISG2.0~2,
Enumeration values None
Tilt Control 3GPP, UNKNOWN 3GPP~3,
UNKNOWN~255
Remote Electrical
Interval values 0~8 Not involved None
Tilt Control
Remote Electrical
Character string 0~19 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~127 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~19 characters Not involved None
Tilt Control
SINGLE_RET~1,
Remote Electrical SINGLE_RET,
Enumeration values STMA~2, None
Tilt Control STMA, MULTI_RET
MULTI_RET~17
Remote Electrical
Interval values 0~29 Not involved None
Tilt Control
Remote Electrical
Interval values 1~8 Not involved None
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Character string 0~31 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~31 characters Not involved None
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.1dBi
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.1dBi
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.1dBi
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.1dBi
Tilt Control
Remote Electrical
Character string 0~6 characters Not involved None
Tilt Control
Remote Electrical UNUSED,
Interval values -100~300
Band800(800MHz), Not involved 0.1degree
Tilt Control
Band900(900MHz),
Remote Electrical UNUSED, UNUSED~0,
Character string Band1500(1500MH
0~5 characters Not involved None
Tilt Control Band800(800MHz), Band800~1,
z),
Band900(900MHz), Band900~2,
Band1800(1800MH
UNUSED, UNUSED~0,
Remote Electrical Band1500(1500MH Band1500~3,
Enumeration values z),
Band800(800MHz), Band800~1, MHz
Tilt Control z), Band1800~4,
Band1900(1900MH
Band900(900MHz), Band900~2,
Band1800(1800MH Band1900~5,
UNUSED~0,
Remote Electrical z),
UNUSED,
Band1500(1500MH Band1500~3,
Enumeration values z), Band2100~6,
Band800~1, MHz
Tilt Control Band2100(2100MH
Band800(800MHz),
z), Band1800~4,
Band1900(1900MH Band2600~7
Band900~2,
z),
Band900(900MHz),
Band1800(1800MH Band1900~5,
Remote Electrical z), UNUSED~0,
Band1500~3,
Enumeration values Band2600(2600MH
Band1500(1500MH
z), Band2100~6, MHz
Tilt Control Band2100(2100MH Band800~1,
Band1800~4,
z)
z),
Band1900(1900MH Band2600~7
z), Band900~2,
Band1900~5,
Band1800(1800MH
z),
Remote Electrical Band2600(2600MH Band1500~3,
Band2100~6,
Enumeration values z),
Band2100(2100MH MHz
Tilt Control z) Band1800~4,
Band2600~7
Band1900(1900MH
z), Band1900~5,
Remote Electrical z),
Band2600(2600MH
Character string 0~31 characters Band2100~6,
Not involved None
Tilt Control Band2100(2100MH
z) Band2600~7
z),
Remote Electrical Band2600(2600MH
Character string 0~17 characters Not involved None
Tilt Control z)
Remote Electrical
Interval values -1800~1800 Not involved 0.1degree
Tilt Control
Remote Electrical
Interval values -1800~1800 Not involved 0.1degree
Tilt Control
Remote Electrical
Interval values 0 Not involved None
Tilt Control
Remote Electrical
Interval values 60~254 Not involved None
Tilt Control
Remote Electrical
Interval values 0 Not involved None
Tilt Control
Remote Electrical
Enumeration values RET_PORT RET_PORT~2 None
Tilt Control
UER_SELF_DEFIN UER_SELF_DEFIN
Remote Electrical E, E~0,
Enumeration values None
Tilt Control RET_ONLY_MULTI RET_ONLY_MULTI
CORE CORE~4
Remote Electrical
Enumeration values ON, OFF ON~0, OFF~1 None
Tilt Control
Remote Electrical
Interval values 10~3500 Not involved mA
Tilt Control
Remote Electrical
Interval values 10~3500 Not involved mA
Tilt Control
Remote Electrical
Interval values 10~3500 Not involved mA
Tilt Control
Remote Electrical
Interval values 10~3500 Not involved mA
Tilt Control
Remote Electrical
Interval values 0~3500 Not involved mA
Tilt Control
Remote Electrical
Enumeration values ON, OFF ON~0, OFF~1 None
Tilt Control
Remote Electrical
Interval values 0~29 Not involved None
Tilt Control
Remote Electrical
Interval values 1~8 Not involved None
Tilt Control
AVAILABLE, AVAILABLE~0,
Remote Electrical
Enumeration values UNAVAILABLE, UNAVAILABLE~1, None
Tilt Control
BREAKLINK BREAKLINK~2
Remote Electrical
Interval values -100~300 Not involved 0.1degree
Tilt Control
Remote Electrical
Interval values 0~11 Not involved None
Tilt Control
Remote Electrical
Interval values 0~62 Not involved None
Tilt Control
Remote Electrical
Interval values 4~5,60~255 Not involved None
Tilt Control
Remote Electrical
Interval values 0~5 Not involved None
Tilt Control
R0A~0, R0B~1,
R0A, R0B, R0C,
Remote Electrical R0C~2, R0D~3,
Enumeration values R0D, R0E, R0F, None
Tilt Control R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
Remote Electrical
Interval values 0~62 Not involved None
Tilt Control
Remote Electrical
Interval values 4~5,60~255 Not involved None
Tilt Control
Remote Electrical
Interval values 0~5 Not involved None
Tilt Control
R0A~0, R0B~1,
R0A, R0B, R0C,
Remote Electrical R0C~2, R0D~3,
Enumeration values R0D, R0E, R0F, None
Tilt Control R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
Remote Electrical
Interval values -100~300 Not involved 0.1degree
Tilt Control
Remote Electrical
Interval values 0~10 Not involved 0.1degree
Tilt Control
Remote Electrical
Interval values 1~2 Not involved None
Tilt Control
Remote Electrical
Interval values 0~29 Not involved None
Tilt Control
Remote Electrical
Character string 0~2 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~17 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~49 characters Not involved None
Tilt Control
Remote Electrical
Interval values 0~62 Not involved None
Tilt Control
Remote Electrical
Interval values 4~5,60~254 Not involved None
Tilt Control
Remote Electrical
Interval values 0~5 Not involved None
Tilt Control
AISG1.1~1,
Remote Electrical AISG1.1, AISG2.0, AISG2.0~2,
Enumeration values None
Tilt Control 3GPP, UNKNOWN 3GPP~3,
UNKNOWN~255
Remote Electrical
Interval values 0~8 Not involved None
Tilt Control
Remote Electrical
Character string 0~19 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~127 characters Not involved None
Tilt Control
Remote Electrical
Character string 0~19 characters Not involved None
Tilt Control
SINGLE_RET~1,
Remote Electrical SINGLE_RET,
Enumeration values STMA~2, None
Tilt Control STMA, MULTI_RET
MULTI_RET~17
Remote Electrical
Interval values 0~29 Not involved None
Tilt Control
Remote Electrical
Interval values 1~2 Not involved None
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Character string 0~31 characters Not involved None
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Interval values 0~359 Not involved degree
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.1dBi
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.1dBi
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.1dBi
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.1dBi
Tilt Control
Remote Electrical
Character string 0~6 characters Not involved None
Tilt Control
Remote Electrical UNUSED,
Interval values -100~300
Band800(800MHz), Not involved 0.1degree
Tilt Control
Band900(900MHz),
Remote Electrical UNUSED, UNUSED~0,
Character string Band1500(1500MH
0~5 characters Not involved None
Tilt Control Band800(800MHz), Band800~1,
z),
Band900(900MHz), Band900~2,
Band1800(1800MH UNUSED~0,
Remote Electrical Band1500~3,
Enumeration values Band1500(1500MH
z), Band800~1, MHz
Tilt Control z), Band1800~4,
Band1900(1900MH Band900~2,
Band1800(1800MH Band1900~5,
Remote Electrical z), Band1500~3,
Enumeration values z), Band2100~6, MHz
Tilt Control Band2100(2100MH Band1800~4,
Band1900(1900MH Band2600~7
z), Band1900~5,
z),
Band2600(2600MH Band2100~6,
Band2100(2100MH
z) Band2600~7
z),
Band2600(2600MH
z)
UNUSED,
Band800(800MHz),
Band900(900MHz),
UNUSED, UNUSED~0,
Band1500(1500MH
Band800(800MHz), Band800~1,
z),
Band900(900MHz), Band900~2,
Band1800(1800MH UNUSED~0,
Remote Electrical Band1500~3,
Enumeration values Band1500(1500MH
z), Band800~1, MHz
Tilt Control z), Band1800~4,
Band1900(1900MH Band900~2,
Band1800(1800MH Band1900~5,
Remote Electrical z), Band1500~3,
Enumeration values z), Band2100~6, MHz
Tilt Control Band2100(2100MH Band1800~4,
Band1900(1900MH Band2600~7
z), Band1900~5,
Remote Electrical z),
Band2600(2600MH
Character string 0~31 characters Band2100~6,
Not involved None
Tilt Control Band2100(2100MH
z) Band2600~7
z),
Remote Electrical Band2600(2600MH
Character string 0~17 characters Not involved None
Tilt Control z)
Remote Electrical
Character string 0~31 characters Not involved None
Tilt Control
Remote Electrical
Interval values 0~255 Not involved
UNSUPPORT~0, 0.25dB
Tilt Control UNSUPPORT,
SUPPORT_PASSB
SUPPORT_PASSB
Remote Electrical Y~1,
Enumeration values Y, None
Tilt Control SUPPORT_VSWR~
SUPPORT_VSWR,
2,
Remote Electrical VSWR/PASSBY
Interval values 0~65535 VSWR/PASSBY~3
Not involved 100KHz
Tilt Control
Remote Electrical
Interval values 0~65535 Not involved 100KHz
Tilt Control
Remote Electrical
Interval values 0~65535 Not involved 100KHz
Tilt Control
Remote Electrical
Interval values 0~65535 Not involved 100KHz
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.25dB
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.25dB
Tilt Control
Remote Electrical
Interval values 0~29 Not involved None
Tilt Control
Remote Electrical
Interval values 1~2 Not involved None
Tilt Control
Remote Electrical
Interval values 0~11 Not involved None
Tilt Control
Remote Electrical
Interval values 0~255 Not involved 0.25dB
Tilt Control
Remote Electrical NORMAL~0,
Enumeration values NORMAL, BYPASS None
Tilt Control BYPASS~1
AVAILABLE, AVAILABLE~0,
Remote Electrical
Enumeration values UNAVAILABLE, UNAVAILABLE~1, None
Tilt Control
BREAKLINK BREAKLINK~2
R0A~0, R0B~1,
R0A, R0B, R0C,
Remote Electrical R0C~2, R0D~3,
Enumeration values R0D, R0E, R0F, None
Tilt Control R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
Remote Electrical
Interval values 0~62 Not involved None
Tilt Control
Remote Electrical
Interval values 0~5 Not involved None
Tilt Control
Remote Electrical
Interval values 4~5,60~254 Not involved None
Tilt Control
Avail_508(Inconsist
ent),
Avail_509(Inconsist
ent, Fault),
Avail_520(Starting
up,In test),
Avail_521(Starting
Remote Electrical up, Fault, In test),
Interval values 0~255 Not involved 0.25dB
Tilt Control Avail_524(Unconfig
Remote Electrical ured,In test), NORMAL~0,
Enumeration values NORMAL, BYPASS
Avail_528(Inconsist None
Tilt Control BYPASS~1
ent,In test),
Avail_529(Inconsist
None Interval values 0~7
ent, Fault, In test), Not involved None
Avail_800(Commun
None Interval values ication
0~1 lost), Not involved None
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
None Interval values 0~5 Avail_20~32,
Not involved None
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
Locked~0,
ication
Locked,lost, In test),
Unlocked,
None Enumeration values Avail_501~1281,
Unlocked~1, None
Avail_821(Fault,
Shutingdown
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Shutingdown~2
Communication
Alarm_1(Warning),
RAT_FDD, Alarm_1~1,
RAT_FDD~0,
Avail_508~1288,
None Enumeration values lost, In test),
Alarm_2(Minor),
RAT_TDD, Alarm_2~2,
RAT_TDD~1, None
Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor),
TDD_ENHANCE Alarm_3~3,
TDD_ENHANCE~2
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
LBBPb(LBBPb), LBBPb~0,
Avail_521~1313,
None Enumeration values Avail_c11(Power
Alarm_5(Major), Alarm_5~5, None
LBBPc(LBBPc) LBBPc~1
Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
-Avail_d21(Starting
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
Avail_d24(Unconfig
ured,
Communication
lost, In test),
Avail_d28(Inconsist
ent, Communication
None Character string Master(Master),
0~255 characters Not involved None
Avail_0(Normal),
NDD(NDD),
Avail_1(Fault), Master~0, NDD~1,
NCD(NCD),
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values Avail_20(In
NDC(NDC),test), None
T),
Avail_21(Fault, In NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
SUBRACK(SUBRA
test), EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values CK),
Avail_500(Starting
EDL(EDL) BOARD~2, None
BOARD(BOARD),
up), SUBBOARD~3,
SUBBOARD(SUBB
Avail_501(Starting SFP~4
None Character string 0~63
OARD), characters
SFP(SFP) Not involved None
up, Fault),
Avail_504(Unconfig
None Character string ured),
0~63 characters Not involved None
Avail_508(Inconsist
ent),
None Character string 0~63 characters
Avail_509(Inconsist Not involved None
ent, Fault),
Avail_520(Starting
None Character string 0~63 characters Not involved None
up,In test),
Avail_521(Starting
None Character string up,
1~39Fault, In test),
characters Not involved None
Avail_524(Unconfig
Normal(Normal),
ured,In test), Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Avail_528(Inconsist Timeout~2, None
Timeout(Timeout),
ent,In test), NULL~4294967295
NULL(NULL)
Avail_529(Inconsist
None Interval values 0~65535
ent, Fault, In test), Not involved None
Avail_800(Commun
None Interval values ication
0~65535 lost), Not involved None
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
None Interval values 0~7 Avail_20~32,
Not involved None
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
ication lost, In test),
None Interval values 0~1 Avail_501~1281,
Not involved None
Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Avail_508~1288,
None Interval values lost,
6~7 In test),
Alarm_2(Minor), Alarm_2~2,
Not involved None
Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
Main Processing off),
Alarm_4(Major), Alarm_4~4,
Active~0,
Avail_521~1313,
and Transport Unit Enumeration values Active, Standby
Avail_c11(Power
Alarm_5(Major), Alarm_5~5, None
Standby~1
Avail_524~1316,
Cold Backup off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
lost),
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
Avail_d29~3369
Communication
lost),
Avail_d08(Inconsist
None Character string 0~23 characters Not involved None

None Character string LMPT(LMPT),


0~19 characters Not involved None
LBBP(LBBP), LMPT~1, LBBP~2,
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values UPEU(UPEU), UTRP~11, None
UTRP(UTRP), USCU~12,
USCU(USCU), UEIU~13
None Interval values 0~4294967295
UEIU(UEIU) Not involved None

CPU(CPU),
None Enumeration values CPU~0, DSP~1 None
DSP(DSP)
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
None Character string Master(Master),
0~255 characters Not involved None
NDD(NDD),
Master~0, NDD~1,
NCD(NCD),
NCD~2, NDC~3,
None Enumeration values CABINET(CABINE
NDC(NDC), None
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values CK),
EDL(EDL) BOARD~2, None
BOARD(BOARD), SUBBOARD~3,
SUBBOARD(SUBB SFP~4
None Character string 0~63 characters
OARD), SFP(SFP) Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None


Alarm_0(Normal), Alarm_0~0,
Alarm_1(Warning), Alarm_1~1,
None Interval values Alarm_2(Minor),
0~5 Alarm_2~2,
Not involved None
Alarm_3(Minor), Alarm_3~3,
Alarm_4(Major), Alarm_4~4,
None Enumeration values Alarm_5(Major),
UIEB UIEB~5
Alarm_5~5, None
Alarm_6(Major), Alarm_6~6,
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values None
Alarm_8(Critical), Alarm_8~8,
Alarm_9(Critical), Alarm_9~9,
Alarm_10(Critical), Alarm_10~10,
Alarm_11(Critical), Alarm_11~11,
Alarm_12(Critical), Alarm_12~12,
Alarm_13(Critical), Alarm_13~13,
Alarm_14(Critical), Alarm_14~14,
Alarm_15(Critical) Alarm_15~15
Avail_509~1289,
Avail_c10(Power
Avail_520~1312,
off),
Avail_521~1313,
Avail_c11(Power
Avail_524~1316,
off, Fault),
Avail_528~1320,
Avail_c12(Uninstall
Avail_529~1321,
ed),
Avail_800~2048,
Avail_c13(Uninstall
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault), None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Avail_821~2081,
ured, Power off),
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power None
Monitor Avail_c11~3089,
off,In test),
Avail_c12~3090,
Avail_c31(Power
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
Avail_d21(Starting
-
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost,
T), In test), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent, Communication
CK), BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
None Character string 0~63Fault,
ent,
OARD), characters
SFP(SFP) Not involved None
Communication
lost, In test)
None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
Avail_524(Unconfig
ured,In test),
Avail_528(Inconsist
ent,In test),
Avail_529(Inconsist
ent, Fault, In test),
Avail_800(Commun
None Interval values ication
0~65535 lost), Not involved None
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
None Interval values 0~65535 Avail_20~32,
Not involved None
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
ication lost, In test),
None Interval values 0~7 Avail_501~1281,
Not involved None
Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Avail_508~1288,
None Interval values lost,
0~1 In test),
Alarm_2(Minor), Alarm_2~2,
Not involved None
Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
Avail_521~1313,
None Interval values 0~5
Avail_c11(Power
Alarm_5(Major), Not involved
Alarm_5~5, None
Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
Avail_d21(Starting
-
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost, In test),
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent, Communication
CK), BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
ent, Fault,
OARD), SFP(SFP)
Communication
lost, In test)
Avail_21(Fault, In
test),
Avail_500(Starting
up),
Avail_501(Starting
up, Fault),
Avail_504(Unconfig
None Character string ured),
0~63 characters Not involved None
Avail_508(Inconsist
ent),
None Character string 0~63 characters
Avail_509(Inconsist Not involved None
ent, Fault),
Avail_520(Starting
None Character string 0~63 characters Not involved None
up,In test),
Avail_521(Starting
None Character string up,
0~63 Fault, In test),
characters Not involved None
Avail_524(Unconfig
ured,In test),
None Character string 1~39 characters
Avail_528(Inconsist Not involved None
ent,In test),
Normal(Normal),
Avail_529(Inconsist Normal~0, Fault~1,
Fault(Fault),
None Enumeration values ent, Fault, In test), Timeout~2, None
Timeout(Timeout),
Avail_800(Commun NULL~4294967295
NULL(NULL)
None Interval values ication
0~65535 lost), Not involved None
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
None Interval values 0~65535 Avail_20~32,
Not involved None
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
ication lost, In test),
None Interval values 0~7 Avail_501~1281,
Not involved None
Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Avail_508~1288,
None Interval values lost,
0~1 In test),
Alarm_2(Minor), Alarm_2~2,
Not involved None
Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
Avail_521~1313,
None Interval values Alarm_5(Major), 16
Avail_c11(Power Not involved
Alarm_5~5, None
Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
lost),
Avail_d20(Starting
up, Communication
lost,In test),
Avail_d21(Starting
up, Fault,
CPU(CPU),
None Enumeration values CPU~0, DSP~1 None
DSP(DSP)
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
-
None Interval values 2147483648~2147 Not involved degree Celsius
Avail_0(Normal),
483647
Avail_1(Fault),
None Character string Master(Master),
Avail_20(In test),
0~255 characters Not involved None
NDD(NDD),
Avail_21(Fault, In Master~0, NDD~1,
NCD(NCD),
test),
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC),
Avail_500(Starting None
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
up),
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
Avail_501(Starting
None Enumeration values CK),
EDL(EDL) BOARD~2, None
up, Fault),
BOARD(BOARD), SUBBOARD~3,
Avail_504(Unconfig
SUBBOARD(SUBB SFP~4
None Character string ured),
0~63 characters Not involved None
OARD), SFP(SFP)
Avail_508(Inconsist
ent),
None Character string 0~63 characters
Avail_509(Inconsist Not involved None
ent, Fault),
Avail_520(Starting
None Character string 0~63 characters Not involved None
up,In test),
Avail_521(Starting
None Character string up,
0~63 Fault, In test),
characters Not involved None
Avail_524(Unconfig
ured,In test),
None Character string 1~39 characters
Avail_528(Inconsist Not involved None
ent,In test),
Normal(Normal),
Avail_529(Inconsist Normal~0, Fault~1,
Fault(Fault),
None Enumeration values ent, Fault, In test), Timeout~2, None
Timeout(Timeout),
Avail_800(Commun NULL~4294967295
NULL(NULL)
None Interval values ication
0~65535 lost), Not involved None
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
None Interval values 0~65535 Avail_20~32,
Not involved None
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
ication lost, In test),
None Interval values 0~7 Avail_501~1281,
Not involved None
Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Avail_508~1288,
None Interval values lost,
0~1 In test),
Alarm_2(Minor), Alarm_2~2,
Not involved None
Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
Avail_521~1313,
None Interval values 18~19
Avail_c11(Power
Alarm_5(Major), Not involved
Alarm_5~5, None
Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
Avail_d01~3329,
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
Avail_d01(Starting
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
lost),
None Character string 0~259 characters Not involved None

None Character string 0~11 characters Not involved None

None Character string 0~23 characters Not involved None

None Character string LMPT(LMPT),


0~19 characters Not involved None
LBBP(LBBP), LMPT~1, LBBP~2,
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values UPEU(UPEU), UTRP~11, None
UTRP(UTRP), USCU~12,
USCU(USCU), UEIU~13
None Interval values 0~4294967295
UEIU(UEIU) Not involved None

CPU(CPU),
None Enumeration values CPU~0, DSP~1 None
DSP(DSP)
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
None Character string Master(Master),
0~255 characters Not involved None
NDD(NDD),
Master~0, NDD~1,
NCD(NCD),
NCD~2, NDC~3,
None Enumeration values CABINET(CABINE
NDC(NDC), None
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values CK),
EDL(EDL) BOARD~2, None
BOARD(BOARD), SUBBOARD~3,
SUBBOARD(SUBB SFP~4
None Character string 0~63 characters
OARD), SFP(SFP) Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

None Interval values 0~1048575 Not involved None

None Character string 1~64 characters Not involved None

None Character string 3 characters Not involved None


DBS3900_LTE(DB
None Character string 2~3 characters
S3900 LTE), Not involved None
BTS3900_LTE(BTS DBS3900_LTE~1,
3900 LTE), BTS3900_LTE~2,
None Enumeration values None
BTS3900A_LTE(BT BTS3900A_LTE~3,
S3900A LTE), BTS3900L_LTE~4
Adaptive Power
Enumeration values BTS3900L_LTE(BT
ON, OFF ON~0, OFF~1 None
Consumption S3900L LTE)
Adaptive Power
Composite type 22:00:00~5:00:00 Not involved None
Consumption
Adaptive Power
Composite type 23:00:00~6:00:00 Not involved None
Consumption
-
None Interval values 180000000~18000 Not involved 1e-6 degree
0000
-
None Interval values 90000000~900000 Not involved 1e-6 degree
Transmission_Pack
00
et_Loss_Rate(Tran
None Character string 0~20 characters
smission Packet Not involved None
Default~0,
Loss Rate),
Default, Normal, Normal~1,
License Transmission_Dela
Enumeration values Demo, Protected, Demo~2, None
Management y(Transmission
Emergency Protected~3,
Delay), Emergency~4
Adaptive Power Poweroff(Power
Transmission_Jitter( Poweroff~0,
Enumeration values None
Consumption off), Normal Jitter),
Transmission Normal~1
Transmission_Pack
Packet_Loss_Rate(
None Character string 0~128 et_Loss_Rate~0,
Packet characters
Loss Rate), Not involved None
Transmission_Dela
Cell_RRC_Connect
y~1,
_Succ_Rate(Cell
None Enumeration values DEG, SEC DEG~0, SEC~1
Transmission_Jitter None
RRC Connect Succ
~2,
Rate),
Packet_Loss_Rate
None Character string Cell_SAEB_Setup_
0~16 characters Not
~3, involved s
Succ_Rate(Cell
Cell_RRC_Connect
SAEB Setup Succ
None Character string 0~16 characters _Succ_Rate~4,
Not involved s
Rate),
Cell_SAEB_Setup_
Cell_Call_Drop_Rat
Succ_Rate~5,
e(Cell Call Drop
None Enumeration values Cell_Call_Drop_Rat None
Rate), Intra-
e~6, Intra-
Frequency_HO_Su
Frequency_HO_Su
None Enumeration values cc_Rate(Intra-
ON, OFF ON~0, OFF~1 None
cc_Rate~7, Inter-
Frequency HO
Frequency_HO_Su
Succ Rate), Inter-
None Interval values 0~4294967295 cc_Rate~8,
Not involvedLTE- None
Frequency_HO_Su
CDMA_Handover_
cc_Rate(Inter
Succ_Rate~9, LTE-
Frequency HO
None Interval values 0~4294967295 WCDMA_Handover
Not involved None
Succ Rate), LTE-
_Succ_Rate~10,
CDMA_Handover_
LTE-
None Interval values Succ_Rate(LTE-
0~4294967295 Not involved None
GERAN_Handover
CDMA Handover 15minutes~15,
15minutes, _Succ_Rate~11
Succ Rate), LTE- 30minutes~30,
None Enumeration values 30minutes,
WCDMA_Handover min
60minutes~60,
60minutes, 1day
_Succ_Rate(LTE- 1day~1440
WCDMA Handover
None Interval values 0~23
Succ Rate), LTE- Not involved h
GERAN_Handover
None Interval values _Succ_Rate(LTE-
1~3 Not involved None
GERAN Handover
Succ Rate)
None Interval values 0~7 Not involved None
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
Avail_20~32,
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
ication lost, In test),
Avail_501~1281,
Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Avail_508~1288,
None Interval values lost,
0~1 In test),
Alarm_2(Minor), Alarm_2~2,
Not involved None
Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
Avail_521~1313,
None Interval values 18~19
Avail_c11(Power
Alarm_5(Major), Not involved
Alarm_5~5, None
Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
-Avail_d21(Starting
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost, In test),
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent,
CK), Communication BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
None Character string 0~63
ent, characters
Fault,
OARD), SFP(SFP) Not involved None
Communication
lost, In test)
None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None


None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

Remote Electrical
Interval values 0~62 Not involved None
Tilt Control
Remote Electrical
Interval values 4~5,60~254 Not involved None
Tilt Control
Remote Electrical
Interval values 0~5 Not involved
UER_SELF_DEFIN None
Tilt Control UER_SELF_DEFIN R0A~0, R0B~1,
E~0,
R0A,
E, R0B, R0C,
Remote Electrical R0C~2, R0D~3,
TMA12DB_ONLY_
Enumeration values R0D, R0E, R0F,
TMA12DB_ONLY_ None
Tilt Control R0E~4, R0F~5,
NON_AISG~1,
R0G, R0H
NON_AISG, R0G~6, R0H~7
TMA24DB_ONLY_
Remote Electrical TMA24DB_ONLY_
Enumeration values NON_AISG~2, None
Tilt Control NON_AISG,
RET_ONLY_COAXI
RET_ONLY_COAXI
Remote Electrical AL~3,
Enumeration values AL,
ON, OFF ON~0, OFF~1
TMA12DB_AISG~5 None
Tilt Control TMA12DB_AISG,
,
Remote Electrical TMA24DB_AISG
Interval values 10~3500 TMA24DB_AISG~6
Not involved mA
Tilt Control
Remote Electrical
Interval values 10~3500 Not involved mA
Tilt Control
Remote Electrical
Interval values 10~3500 Not involved mA
Tilt Control
Remote Electrical
Interval values 10~3500 Not involved mA
Tilt Control
Remote Electrical
Interval values 0~1000 Not involved m
Tilt Control
Remote Electrical
Interval values 0~50 Not involved ns
Tilt Control
Remote Electrical
Interval values 0~50 Not involved ns
Tilt Control
Remote Electrical
Interval values 0~3500 Not involved mA
Tilt Control
Remote Electrical
Enumeration values ON, OFF ON~0, OFF~1 None
Tilt Control

None Interval values 0~62 Not involved None

None Interval values 0~1,4~5,60~254 Not involved None

None Interval values 0~5 Not involved None


None Interval values 0~5 Not involved None
0.614~0, 1.25~1,
0.614, 1.25, 2.5,
None Enumeration values 2.5~2, 4.9~3, Gbit/s
4.9, NULL
NULL~4294967295
BLOCK~0,
None Enumeration values BLOCK, UNBLOCK None
UNBLOCK~1
Locked~0,
Locked, Unlocked,
None Enumeration values Unlocked~1, None
Shutingdown
Shutingdown~2
None Enumeration values ON, OFF ON~0, OFF~1 None

None Interval values 15~100 Not involved 0.1

None Interval values 15~30 Not involved 0.1

None Interval values 0~3 Not involved None

None Interval values 0~249 Not involved None

TRUNK~42949672
None Enumeration values TRUNK None
LO_TD(LTE(TDD)), 95
LO(LTE(FDD)), LO_TD~4, LO~8,
None Enumeration values CL(CDMA_LTE), CL~40, GL~72, None
GL(GSM_LTE), UL~136
UL(UMTS_LTE)
None Interval values 1,2,4,8 Not involved None

None Interval values 1,2,4,8 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~10000 Not involved 10mW

None Interval values 0~65535 Not involved 0.1dB

None Interval values 0~4294967295 Not involved 0.1MHz

None Interval values -100~200 Not involved degree Celsius


Avail_528(Inconsist
ent,In test),
Avail_529(Inconsist
ent, Fault, In test),
Avail_800(Commun
ication lost),
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
LO_TD~4, LO~8,
Communication
None Interval values 0~6 Avail_20~32,
WL~20, CL~40,
Not involved None
lost),
Avail_21~33,
CWL~56, GL~72,
Avail_820(Commun
Avail_500~1280,
GWL~88,
CONNECTHEAD(A
ication
LO_TD, lost,
LO,InWL,test),
None Character string 0~24 characters Avail_501~1281,
Not involved
GCL~104, None
ccess from
Avail_821(Fault,
Alarm_0(Normal),
CL, CWL, GL, chain Alarm_0~0,
Avail_504~1284,
GCWL~120,
head
GWL,or
Communicationring GCWL,
Alarm_1(Warning),
GCL, head), Alarm_1~1,
Avail_508~1288,
UL~136, UWL~152,
None Enumeration values CONNECTTAIL(Ac
lost, In test),
Alarm_2(Minor),
UL, UWL, UCL, CONNECTHEAD~0
Alarm_2~2, None
Avail_509~1289,
cess from
Avail_c10(Power
Alarm_3(Minor),
UCWL, UGL,ring tail), ,UCL~168,
CONNECTTAIL~1,
Alarm_3~3,
Avail_520~1312,
UCWL~184,
CONNECTBOTH(A
off),
Alarm_4(Major),
UGWL, UGCL, CONNECTBOTH~2
Alarm_4~4,
Avail_521~1313,
UGL~200,
None Enumeration values ccess from
Avail_c11(Power
Alarm_5(Major),
UGCWL, both
NULL ,
Alarm_5~5, None
Avail_524~1316,
UGWL~216,
ends
off, of the ring),
Fault),
Alarm_6(Major), SEPERATEBYBRE
Alarm_6~6,
Avail_528~1320,
UGCL~232,
SEPERATEBYBRE
Avail_c12(Uninstall
Alarm_7(Major), AK~3,
Alarm_7~7,
Fault Management Enumeration values Avail_529~1321,
UGCWL~248, None
AK(Seperated
ed),
Alarm_8(Critical), by LINKDOWN~4
Alarm_8~8,
Avail_800~2048,
NULL~65535
break points),
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values LINKDOWN(Link
ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
down)
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
-Avail_d21(Starting
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost,
T), In test), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent,
CK), Communication BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
None Character string 0~63
ent,
OARD), characters
Fault,SFP(SFP) Not involved None
Communication
lost, In test)
Avail_0(Normal),
Avail_1(Fault),
Avail_20(In test),
Avail_21(Fault, In
test),
Avail_500(Starting
up),
Avail_501(Starting
None Character string 0~63 characters Not involved None
up, Fault),
Avail_504(Unconfig
None Character string ured),
0~63 characters Not involved None
Avail_508(Inconsist
ent),
None Character string 0~63 characters
Avail_509(Inconsist Not involved None
ent, Fault),
Avail_520(Starting
None Character string 1~39 characters Not involved None
up,In test),
Normal(Normal),
Avail_521(Starting Normal~0, Fault~1,
Fault(Fault),
up, Fault, In test),
None Enumeration values Timeout~2, None
Timeout(Timeout),
Avail_524(Unconfig NULL~4294967295
NULL(NULL)
ured,In test),
None Interval values 0~65535
Avail_528(Inconsist Not involved None
ent,In test),
Avail_529(Inconsist
None Interval values 0~65535
ent, Fault, In test), Not involved None
Avail_800(Commun
None Interval values ication
0~62 lost), Not involved None
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
None Interval values 4~5 Avail_20~32,
Not involved None
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
ication lost, In test),
None Interval values 0~5 Avail_501~1281,
Not involved None
Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Avail_508~1288,
None Enumeration values lost,
MRFU, In test),
Alarm_2(Minor),
LRFU Alarm_2~2,
MRFU~2, LRFU~3 None
Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
off),
Alarm_4(Major), Locked~0,
Alarm_4~4,
Locked, Unlocked, Avail_521~1313,
None Enumeration values Avail_c11(Power
Alarm_5(Major), Unlocked~1,
Alarm_5~5, None
Shutingdown Avail_524~1316,
off, Fault),
Alarm_6(Major), Shutingdown~2
Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
Avail_d09(Inconsist
UEIU(UEIU)
ent, Fault,
Communication
lost),
Avail_d20(Starting
up, Communication
None Interval values 0~4294967295 Not involved None

CPU(CPU),
None Enumeration values CPU~0, DSP~1 None
DSP(DSP)
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
None Character string Master(Master),
0~255 characters Not involved None
NDD(NDD),
Master~0, NDD~1,
NCD(NCD),
NCD~2, NDC~3,
None Enumeration values CABINET(CABINE
NDC(NDC), None
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values CK),
EDL(EDL) BOARD~2, None
BOARD(BOARD), SUBBOARD~3,
SUBBOARD(SUBB SFP~4
None Enumeration values ON, OFFSFP(SFP)
OARD), ON~0, OFF~1 None

None Interval values 15~100 Not involved 0.1

None Interval values 15~30 Not involved 0.1

None Interval values 0~3 Not involved None

None Interval values 0~249 Not involved None

TRUNK~42949672
None Enumeration values TRUNK None
LO_TD(LTE(TDD)), 95
LO(LTE(FDD)), LO_TD~4, LO~8,
None Enumeration values CL(CDMA_LTE), CL~40, GL~72, None
GL(GSM_LTE), UL~136
UL(UMTS_LTE)
None Interval values 1,2,4,8 Not involved None

None Interval values 1,2,4,8 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~10000 Not involved 10mW


None Interval values 0~65535 Not involved 0.1dB

None Interval values 0~4294967295 Not involved 0.1MHz

None Interval values -100~200 Not involved degree Celsius


LO_TD~4, LO~8,
None Interval values 0~6 WL~20, CL~40,
Not involved None
CWL~56, GL~72,
CONNECTHEAD(A GWL~88,
None Character string LO_TD,
0~24 LO, WL,
characters Not involved None
ccess fromGL,chain GCL~104,
CL, CWL,
head or ring head), GCWL~120,
GWL, GCL, GCWL,
CONNECTTAIL(Ac UL~136, UWL~152,
CONNECTHEAD~0
None Enumeration values UL, UWL, UCL, None
cess from ring tail), UCL~168,
, CONNECTTAIL~1,
UCWL, UGL,
CONNECTBOTH(A UCWL~184,
CONNECTBOTH~2
UGWL, UGCL,
None Enumeration values ccess
UGCWL, from both
NULL ,UGL~200, None
ends of the ring), UGWL~216,
SEPERATEBYBRE
SEPERATEBYBRE UGCL~232,
AK~3,
None Character string 0~63 characters
AK(Seperated by Not involved
UGCWL~248,
LINKDOWN~4 None
break points), NULL~65535
None Character string LINKDOWN(Link
0~63 characters Not involved None
down)

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

None Interval values 0 Not involved None

None Interval values 60~254 Not involved None

None Interval values 0 Not involved None

None Character string 0~30 characters Not involved None


Alarm_0(Normal), Alarm_0~0,
Alarm_1(Warning), Alarm_1~1,
None Enumeration values Alarm_2(Minor),
MRRU, LRRU Alarm_2~2,
MRRU~0, LRRU~1 None
Alarm_3(Minor), Alarm_3~3,
Alarm_4(Major), Locked~0,
Alarm_4~4,
Locked, Unlocked,
None Enumeration values Alarm_5(Major), Unlocked~1,
Alarm_5~5, None
Shutingdown
Alarm_6(Major), Shutingdown~2
Alarm_6~6,
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values None
Alarm_8(Critical), Alarm_8~8,
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled),
Alarm_10(Critical), Enabled~0,
Alarm_10~10,
None Enumeration values None
Disabled(Disabled)
Alarm_11(Critical), Disabled~1
Alarm_11~11,
Alarm_12(Critical), Alarm_12~12,
Alarm_13(Critical), Alarm_13~13,
Alarm_14(Critical), Alarm_14~14,
Alarm_15(Critical) Alarm_15~15
Avail_c11(Power
Avail_524~1316,
off, Fault),
Avail_528~1320,
Avail_c12(Uninstall
Avail_529~1321,
ed),
Avail_800~2048,
Avail_c13(Uninstall
Avail_801~2049,
ed, Fault),
Avail_820~2080,
Avail_c14(Unconfig
Avail_821~2081,
ured, Power off),
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power None
Monitor Avail_c11~3089,
off,In test),
Avail_c12~3090,
Avail_c31(Power
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
-Avail_d21(Starting
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost, In test),
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent,
CK), Communication BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
None Enumeration values ON, OFFSFP(SFP)
ent, Fault,
OARD), ON~0, OFF~1 None
Communication
lost, In test)
None Interval values 15~100 Not involved 0.1

None Interval values 15~30 Not involved 0.1

None Interval values 0~3 Not involved None

None Interval values 0~249 Not involved None

TRUNK~42949672
None Enumeration values TRUNK None
LO_TD(LTE(TDD)), 95
LO(LTE(FDD)), LO_TD~4, LO~8,
None Enumeration values CL(CDMA_LTE), CL~40, GL~72, None
GL(GSM_LTE), UL~136
UL(UMTS_LTE)
None Interval values 1,2,4,8 Not involved None

None Interval values 1,2,4,8 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~4294967295 Not involved 0.2MHz

None Interval values 0~10000 Not involved 10mW

None Interval values 0~65535 Not involved 0.1dB

None Interval values 0~4294967295 Not involved 0.1MHz

None Interval values -100~200 Not involved degree Celsius


LO_TD~4, LO~8,
None Interval values 0~6 WL~20, CL~40,
Not involved None
CWL~56, GL~72,
CONNECTHEAD(A GWL~88,
None Character string LO_TD,
0~24 LO, WL,
characters Not involved None
ccess fromGL,chain GCL~104,
CL, CWL,
head GCWL~120,
GWL,or ring GCWL,
GCL, head),
CONNECTTAIL(Ac UL~136, UWL~152,
CONNECTHEAD~0
None Enumeration values UL, UWL, UCL, None
cess
UCWL,from ring tail),
UGL, ,UCL~168,
CONNECTTAIL~1,
CONNECTBOTH(A UCWL~184,
CONNECTBOTH~2
UGWL, UGCL,
None Enumeration values ccess from both UGL~200,
, None
UGCWL, NULL
ends of the ring), UGWL~216,
SEPERATEBYBRE
SEPERATEBYBRE UGCL~232,
AK~3,
None Character string 0~63 characters
AK(Seperated by Not involved
UGCWL~248,
LINKDOWN~4 None
break points), NULL~65535
None Character string LINKDOWN(Link
0~63 characters Not involved None
down)

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None
None Interval values 0~65535 Not involved None

None Interval values 0~249 Not involved None

CHAIN, RING, CHAIN~0, RING~1,


None Enumeration values None
LOADBLANCE LOADBLANCE~2

None Enumeration values COLD, HOT COLD~0, HOT~1 None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~5 Not involved None

None Interval values 0~5 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~5 Not involved None

None Interval values 0~5 Not involved None

None Interval values 0~4,255 Not involved None

None Interval values 0~4,255 Not involved None


LOCALPORT(local
port), LOCALPORT~0,
None Enumeration values None
PEERPORT(peer PEERPORT~1
port)
None Interval values 0~3 Not involved None

None Interval values 0~3 Not involved None

None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None

None Interval values 0~7 Not involved None

None Enumeration values ON, OFF ON~0, OFF~1 None

None Interval values 0~44 Not involved 0.5dB


None Enumeration values ON, OFF ON~0, OFF~1 None

None Interval values 0~11 Not involved None


-
None Interval values 180000000~18000 Not involved 1e-6 degree
0000
-
None Interval values 90000000~900000 Not involved 1e-6 degree
00
1T1R~0, 1T2R~1,
1T1R, 1T2R, 2T2R,
None Enumeration values 2T2R~3, 2T4R~4, None
2T4R, 4T4R, 8T8R
4T4R~5, 8T8R~6
None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None


R0A~0, R0B~1,
R0A, R0B, R0C,
R0C~2, R0D~3,
None Enumeration values R0D, R0E, R0F, None
R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None


R0A~0, R0B~1,
R0A, R0B, R0C,
R0C~2, R0D~3,
None Enumeration values R0D, R0E, R0F, None
R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None


R0A~0, R0B~1,
R0A, R0B, R0C,
R0C~2, R0D~3,
None Enumeration values R0D, R0E, R0F, None
R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None


R0A~0, R0B~1,
R0A, R0B, R0C,
R0C~2, R0D~3,
None Enumeration values R0D, R0E, R0F, None
R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None


None Interval values 0~5 Not involved None
R0A~0, R0B~1,
R0A, R0B, R0C,
R0C~2, R0D~3,
None Enumeration values R0D, R0E, R0F, None
R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None


R0A~0, R0B~1,
R0A, R0B, R0C,
R0C~2, R0D~3,
None Enumeration values R0D, R0E, R0F, None
R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None


R0A~0, R0B~1,
R0A, R0B, R0C,
R0C~2, R0D~3,
None Enumeration values R0D, R0E, R0F, None
R0E~4, R0F~5,
R0G, R0H
R0G~6, R0H~7
None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None


R0A~0, R0B~1,
R0A, R0B, R0C,
R0C~2, R0D~3,
None Enumeration values R0D, R0E, R0F, None
R0E~4, R0F~5,
R0G, R0H
NormalMIMO(Norm
RRU Channel R0G~6, R0H~7
al MIMO), NormalMIMO~0,
Cross Connection Enumeration values None
AIDMIMO(mutual- AIDMIMO~1
Under MIMO
aid MIMO)
None Character string 0~30 characters Not involved None

None Interval values -32767~32767 Not involved m

None Interval values 0~1800000 Not involved m

None Interval values 0~1800000 Not involved m

None Interval values 0~179 Not involved degree

None Interval values 0~990 Not involved m

None Interval values 0~100 Not involved %


COMBTYPE_SING COMBTYPE_SING
LE_RRU, LE_RRU~0,
None Enumeration values None
COMBTYPE_MULT COMBTYPE_MULT
I_RRU I_RRU~1
None Enumeration values DEG, SEC DEG~0, SEC~1 None

None Character string 0~16 characters Not involved s

None Character string 0~16 characters Not involved s

None Enumeration values FALSE, TRUE FALSE~0, TRUE~1 None

None Interval values 0~500 Not involved 0.1dBm

License Normal~0,
Enumeration values Normal, NoLicense None
Management NoLicense~1

None Character string 0~40 characters Not involved 0.2MHz

None Character string 0~40 characters Not involved 0.2MHz

None Interval values 0~62 Not involved None

None Interval values 0~1,4~5,60~254 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~5 Not involved None


INPOSITION~0,
INPOSITION, NOTINPOSITION~
None Enumeration values NOTINPOSITION, 1, None
INVALID INVALID~42949672
SFP~0, ESFP~1,
SFP, ESFP, 95
ELEC_SFP~2,
None Enumeration values ELEC_SFP, None
UNKNOWN~42949
UNKNOWN
67295
None Character string 0~15 characters Not involved None
SINGLEMODE~0,
SINGLEMODE,
MULTIMODE~1,
None Enumeration values MULTIMODE, None
UNKNOWN~42949
UNKNOWN
67295
None Interval values 0~65535 Not involved nm

None Interval values 0~255 Not involved 100Mbit/s

None Interval values 0~255 Not involved km

None Interval values 0~255 Not involved 100m

None Interval values 0~255 Not involved 10m

None Interval values 0~255 Not involved 10m

0.001 degree
None Interval values -128000~128000 Not involved
Celsius
None Interval values 0~65535 Not involved 100microvolt

None Interval values 0~65535 Not involved 2microampere

None Interval values 0~65535 Not involved 0.1microwatt

None Interval values 0~65535 Not involved 0.1microwatt

None Interval values 0~255 Not involved m

None Interval values 0~62 Not involved None

None Interval values 4~5,60~254 Not involved None

None Interval values 0~5 Not involved None

None Interval values 0~7 Not involved None

None Enumeration values ON, OFF ON~0, OFF~1 None

None Interval values 100~2500 Not involved 0.01

None Enumeration values ON, OFF ON~0, OFF~1 None

None Interval values 0~4294967295 Not involved m

None Interval values 0~10000 Not involved 10mW

None Interval values 0 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None


DEACTIVATED(De
activated), DEACTIVATED~0,
None Enumeration values None
ACTIVATED(Activat ACTIVATED~1
UNAVAILABLE(Una
ed)
vailable), UNAVAILABLE~0,
None Enumeration values None
AVAILABLE(Availab AVAILABLE~1
le)
None Interval values 1~4 Not involved None

None Interval values 0 Not involved None

None Interval values 0~7 Not involved None


None Interval values 0~1 Not involved None

None Interval values 0~5 Not involved None

None Interval values 0~7 Not involved None


DEACTIVATED(De
activated), DEACTIVATED~0,
None Enumeration values None
ACTIVATED(Activat ACTIVATED~1
UNAVAILABLE(Una
ed)
vailable), UNAVAILABLE~0,
None Enumeration values None
AVAILABLE(Availab AVAILABLE~1
le)
None Interval values 1~4 Not involved None
Multi-mode BS
Common Reference Interval values 0 Not involved None
Clock(eNodeB) DEACTIVATED(De
activated), DEACTIVATED~0,
None Enumeration values None
ACTIVATED(Activat ACTIVATED~1
UNAVAILABLE(Una
ed)
vailable), UNAVAILABLE~0,
None Enumeration values None
AVAILABLE(Availab AVAILABLE~1
le)
None Interval values 0~1 Not involved None

IN(Input),
None Enumeration values IN~0, OUT~1 None
OUT(Output)

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~5 Not involved None


TWISTED-
TWISTED-PAIR~0,
None Enumeration values PAIR(Twisted-Pair), None
COAXIAL~1
COAXIAL(Coaxial)
None Interval values 0~1000 Not involved m
DEACTIVATED(De
activated), DEACTIVATED~0,
None Enumeration values None
ACTIVATED(Activat ACTIVATED~1
UNAVAILABLE(Una
ed)
vailable), UNAVAILABLE~0,
None Enumeration values None
AVAILABLE(Availab AVAILABLE~1
le)
None Interval values 0~100000 Not involved ns

None Interval values 1~4 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None


USER_CONFIG(Us
er Config),
None Interval values 0~7
SEARCH_WITH_D Not involved
USER_CONFIG~0, None
URATION(Search SEARCH_WITH_D
with duration), URATION~1,
None Enumeration values None
SEARCH_WITH_P SEARCH_WITH_P
-RECISION(Search RECISION~2,
None Interval values with precision),
180000000~18000 AUTO_SEARCH~3
Not involved 1e-6 degree
AUTO_SEARCH(A
0000
-uto Search)
None Interval values 90000000~900000 Not involved 1e-6 degree
00
None Interval values -1000~10000 Not involved m

None Interval values 0~89 Not involved degree

None Interval values 0~100000 Not involved ns

None Interval values 1~2880 Not involved min

None Interval values 1~100 Not involved m


TWISTED-
TWISTED-PAIR~0,
None Enumeration values PAIR(Twisted-Pair), None
COAXIAL~1
COAXIAL(Coaxial)
None Interval values 0~1000 Not involved m

Lock(Yes),
None Enumeration values Lock~0, Unlock~1 None
Unlock(No)
Valid(Valid),
None Enumeration values Valid~0, Invalid~1 None
Invalid(Invalid)
Valid(Valid),
None Enumeration values Valid~0, Invalid~1 None
Invalid(Invalid)
NotFixed(Not NotFixed~0,
None Enumeration values NOTEXIST(Inexiste None
Fixed), Fixed(Fixed)
nt), Fixed~1
ANTENNASHORTE
Enabled(Enabled), Enabled~0,
None Enumeration values D(Antenna None
Disabled(Disabled) Disabled~1
Shorted),
M12M(M12M),
ANTENNAOPENE
Valid(Valid),
UT(UT), RT(RT), NOTEXIST~0,
None Enumeration values D(Antenna Valid~0, Invalid~1
ANTENNASHORTE None
Invalid(Invalid)
JPS15L(JPS15L), M12M~0, UT~1,
Opened),
K161(K161), D~1, JPS15L~3,
RT~2,
None Interval values SELF_CHECK_FAI
GG16(GG16),
0~100 ANTENNAOPENE
K161~4, GG16~5,
Not involved None
LURE(Self-check
JNS100(JNS100), D~2,
JNS100~6,
Failure),
RGPS(RGPS), SELF_CHECK_FAI
RGPS~7,
None Enumeration values COMEXCEPTION(
CWAIN(CWAIN), LURE~3,
CWAIN~8, None
COM Port
GPS(GPS),
RTSMT(RTSMT), COMEXCEPTION~
RTSMT~9,
Communication
GLONASS(GLONA
UBLOX5(UBLOX5), 4, NORMAL~5,
UBLOX5~10,
None Enumeration values Fault),
SS), UNKNOWN~6, None
BD7702(BD7702), BD7702~11,
NORMAL(Normal),
GPS/GLONASS(G
NAVIOR(NAVIOR), USCUINVALID~7,
NAVIOR~12,
None Interval values UNKNOWN(Unkno
PS/GLONASS
PPSTOD(PPSTOD)
0~100 with UNKNOWN_STAR
PPSTOD~13,
Not involved None
GPS~0,
,wn
GPS Exception),
Prioritized),
M1000(M1000), _CARD~8
M1000~14,
GLONASS~1,
USCUINVALID(US
COMPASS(COMPA
TRGPS(TRGPS), TRGPS~15,
GPS/GLONASS~2,
None Enumeration values CU
SS),Invalid),
BD7702CMS(BD77 BD7702CMS~16, None
COMPASS~3,
UNKNOWN_STAR
COMPASS/GPS(C
02CMS), OEM4~17,
COMPASS/GPS~4,
_CARD(Unknown
OMPASS/GPS
OEM4(OEM4), with UNKNOWN~65535
None Interval values 0~100 GPS/COMPASS~5
Not involved None
Star Card)
COMPASS
UNKNOWN(Unkno
Prioritized),
wn)
GPS/COMPASS(G
PS/COMPASS with
GPS Prioritized)
DEACTIVATED(De
activated), DEACTIVATED~0,
None Enumeration values None
ACTIVATED(Activat ACTIVATED~1
ed)
None Interval values 1~4 Not involved None

None Interval values 0~1 Not involved None


IEEE1588 V2 Clock
HW_DEFINED(Hua
Synchroniztion
Wei Defined HW_DEFINED~0,
Clock over IP Enumeration values None
Protocol), PTP(PTP PTP~1
(Huawei
Protocol)
proprietary)
None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None


IEEE1588 V2 Clock
Synchroniztion
Clock over IP IP address type Valid IP address Not involved None
(Huawei
proprietary)
IEEE1588 V2 Clock
IP address type Valid IP address Not involved None
Synchroniztion
IEEE1588 V2 Clock
Interval values 0~127 Not involved None
Synchroniztion
E2E(E2E),
None Enumeration values E2E~0, P2P~1 None
P2P(P2P)

None Enumeration values OFF(OFF), ON(ON) OFF~0, ON~1 None

None Interval values 0~255 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~255 Not involved None

None Interval values 0~4294967295 Not involved None


DEACTIVATED(De
activated), DEACTIVATED~0,
None Enumeration values None
ACTIVATED(Activat ACTIVATED~1
UNAVAILABLE(Una
ed)
vailable), UNAVAILABLE~0,
None Enumeration values None
AVAILABLE(Availab AVAILABLE~1
le)
UNICAST(Unicast),
IEEE1588 V2 Clock UNICAST~0,
Enumeration values L2_MULTICAST(L2 None
Synchroniztion L2_MULTICAST~2
Multicast)
Synchronization
with Ethernet(ITU-T Interval values -100000~100000 Not involved ns
G.8261) ONE_STEP(One
Step), ONE_STEP~0,
None Enumeration values None
TWO_STEP(Two TWO_STEP~1
Step)
None Interval values 0~4094 Not involved None
-
None Interval values 2147483648~2147 Not involved None
483647
None Interval values 1~4 Not involved None
1/16(1/16), 1/8(1/8), 1/16~0, 1/8~1,
1/4(1/4), 1/2(1/2), 1/4~2, 1/2~3,
None Enumeration values 1/2(1/2), 1.0(1.0), Hz
1.0(1.0), 2.0(2.0), 1.0~4, 1.0~1,
1/2~0, 2.0~5,
2.0(2.0),
4.0(4.0), 4.0(4.0),
8.0(8.0) 4.0~6,
2.0~2, 8.0~7
4.0~3,
8.0(8.0), 16.0(16.0),
None Enumeration values 8.0~4, 16.0~5, Hz
32.0(32.0),
32.0~6, 64.0~7,
64.0(64.0),
128.0~8
None Interval values 128.0(128.0)
0~255 Not involved None

1588V2(1588V2), 1588V2~0,
None Enumeration values None
G.8265.1(G.8265.1) G.8265.1~1

None Interval values 60~1000 Not involved s

None Interval values 0 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

DISABLE~0,
None Enumeration values DISABLE, ENABLE None
ENABLE~1
DEACTIVATED(De
Synchronization
activated), DEACTIVATED~0,
with Ethernet(ITU-T Enumeration values None
ACTIVATED(Activat ACTIVATED~1
G.8261) UNAVAILABLE(Una
Clock Source ed)
vailable), UNAVAILABLE~0,
Switching Manually Enumeration values None
AVAILABLE(Availab AVAILABLE~1
or Automatically
le)
AVAILABLE(Availab
None Interval values 1~4
le), Not involved None
UNAVAILABLE(Una AVAILABLE~0,
vailable), UNAVAILABLE~1,
None Enumeration values None
UNSUPPORT(Unsu UNSUPPORT~2,
pport),
FORBID(Forbid), PARTAVAILABLE~3
FORBID~0,
None Enumeration values PARTAVAILABLE(P
ALLOW(Allow), None
GPS(GPS Clock),
artial Available) ALLOW~1, NA~2
NA(N/A)
BITS(BITS Clock),
None Interval values IPCLK(IP
1~4 Clock), Not involved None
SYNCETH(SyncEth
GPS~0, BITS~1,
Clock),
0(0), 1(1),
None Enumeration values LINECLK(Line IPCLK~2,
0~0, 1~1, AUTO~2 None
AUTO(AUTO) SYNCETH~3,
Clock), TOD(TOD
Multi-mode BS LINECLK~4,
Clock),
Common Reference Enumeration values TOD~5, None
PEERCLK(Peer
Clock(eNodeB) PEERCLK~6,
Clock),
AUTO(Auto), AUTO~0,
SYNCETH+IPCLK~
Fault Management Enumeration values SYNCETH+IPCLK(
MANUAL(Manual), MANUAL~1,
7, None
SyncEth Clock+IP
FREE(Free) FREE~2
GPS+SYNCETH~8
Clock),
FREQ(FREQ), FREQ~0,
None Enumeration values GPS+SYNCETH(G None
PHASE(PHASE) PHASE~1
PS Clock+SyncEth
Clock)
NORMAL(Normal),
LOST(Lost),
UNAVAILABLE(Una
NORMAL~0,
vailable),
LOST~1,
FREDVAT(Frequen
GPS(GPS Clock), UNAVAILABLE~2,
cy Deviation),
FREERUNNING(Fr
BITS(BITS Clock), FREDVAT~3,
JITTER(Jitter),
ee running),
IPCLK(IP Clock),
None Enumeration values JITTER~4, None
PHASEOUTSCOP
FASTTRACKING(F
SYNCETH(SyncEth FREERUNNING~0,
PHASEOUTSCOP
GPS~0, BITS~1,
E(Phaseoutscope),
ast tracking),
Clock), FASTTRACKING~1
E~5,
IPCLK~2,
None Enumeration values UNKNOWN(Unkno
LOCKED(Locked),
LINECLK(Line ,UNKNOWN~6,
LOCKED~2, None
wn),
HOLDOVER(Holdo SYNCETH~3,
HOLDOVER~3,
Clock), TOD(TOD DIFFSRC~7
DIFFSRC(Inconsist
QL-PRC(QL-PRC),
ver), LINECLK~4,
UNKNOWN~4
Clock),
None Enumeration values ent Clock
QL-SSU-A(QL-
UNKNOWN(Unkno TOD~5, None
PEERCLK(Peer QL-PRC~2, QL-
References)
SSU-A),
wn) QL-SSU- PEERCLK~6,
Clock), SSU-A~4, QL-SSU-
B(QL-SSU-B), QL- SYNCETH+IPCLK~
None Enumeration values SYNCETH+IPCLK( B~8, QL-EEC2~10, None
EEC2(QL-EEC2), 7,
SyncEth Clock+IP QL-EEC1~11, QL-
QL-EEC1(QL- GPS+SYNCETH~8
Clock), DNU~15
None Interval values LBR0(NULL),
EEC1),
0~249 QL- Not involved None
GPS+SYNCETH(G
LBR1(1.25),
DNU(QL-DNU)
PS Clock+SyncEth LBR0~0, LBR1~1,
LBR2(2.5),
Clock)
NEGOTIATED(Neg LBR2~2, LBR3~4,
None Enumeration values LBR3(3.0), Gbit/s
otiated), LBR4~8, LBR5~16,
LBR4(4.9), NEGOTIATED~0,
NEGOTIATING(Ne LBR6~32
LBR5(6.1),
LBR0(NULL), NEGOTIATING~1,
None Enumeration values gotiating),
LBR6(9.8) None
LBR1(1.25), NOTREADY~2,
NOTREADY(Not LBR0~0, LBR1~1,
LBR2(2.5), TIMEOUT~3
ready),
NEGOTIATED(Neg LBR2~2, LBR3~4,
None Enumeration values LBR3(3.0),
TIMEOUT(Timeout) Gbit/s
otiated), LBR4~8, LBR5~16,
LBR4(4.9), NEGOTIATED~0,
NEGOTIATING(Ne LBR6~32
LBR5(6.1), NEGOTIATING~1,
None Enumeration values gotiating),
LBR6(9.8) None
NOTREADY~2,
NOTREADY(Not
TIMEOUT~3
ready),
None Interval values 0~62
TIMEOUT(Timeout) Not involved None

None Interval values 0~254 Not involved None

None Interval values 0~7 Not involved None

HEAD(Head), HEAD~4294967294
None Enumeration values LBR0(NULL), None
TAIL(Tail)
LBR1(1.25), , TAIL~4294967295
LBR0~0, LBR1~1,
LBR2(2.5),
LBR2~2, LBR3~4,
None Enumeration values LBR3(3.0), Gbit/s
LBR4~8, LBR5~16,
LBR4(4.9),
LBR6~32
LBR5(6.1),
None Enumeration values DC(DC),
LBR6(9.8) AC(AC) DC~0, AC~1 None

DISABLE(Disable), DISABLE~0,
None Enumeration values APM30(APM30), None
ENABLE(Enable)
TMC(TMC), ENABLE~1
APM30~128,
BBC(BBC),
None Interval values 0~62 TMC~129,
Not involved None
PS4890(PS4890),
BBC~130,
OMB(OMB),
PS4890~133,
RFC(RFC),
None Enumeration values OMB~134, None
BTS3900(BTS3900
RFC~135,
),
BTS3900~136,
None Character string BTS3900L(BTS390
0~79 characters Not involved None
BTS3900L~137,
0L),
VIRTUAL~142
VIRTUAL(Virtual
None Character string 0~31 characters
BBU3900(BBU3900
Cabinet) Not involved None
Subrack),
RFU(RFU
None Interval values 0~62
Subrack), Not involved None
PMU(Power BBU3900~128,
None Interval values Subrack),
0~254 RFU~129,
Not involved None
TCU(Temperature PMU~130,
Control Subrack), TCU~131,
None Enumeration values FMU(FMU FMU~132, None
Subrack), RRU~134,
RRU(RRU EMU~137,
Subrack), PICO~147,
EMU(EMU UNKNOW~255
Subrack),
PICO(PICO
Subrack),
UNKNOW(Unknow)
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
Avail_20~32,
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
ication lost, In test),
Avail_501~1281,
Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
AC220V(AC 220V), Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
DC-48V(DC -48V), Avail_508~1288,
None Character string lost,
0~79 Incharacters
test),
Alarm_2(Minor), Alarm_2~2,
Not involvedDC- None
DC+28V(DC +28V), AC220V~0,
Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
DC+24V(DC +24V), 48V~1, DC+28V~2,
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
DC-48V-2(DC DC+24V~3, DC-
Avail_521~1313,
None Enumeration values Avail_c11(Power
Alarm_5(Major), Alarm_5~5, None
-48V), AC110V(AC 48V-2~4,
Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
110V), RDC- AC110V~5, RDC-
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values 48V(RDC -48V), 48V~6, NDC-48V~7
Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
NDC-48V(NDC Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
-48V)
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
-Avail_d21(Starting
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost, In test),
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent,
CK), Communication BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
None Character string 0~63
ent, characters
Fault,
OARD), SFP(SFP) Not involved None
Communication
lost, In test)
None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None


None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

None Interval values 0~62 Not involved None

None Interval values 40~59 Not involved None

None Interval values 0 Not involved None

Environment
Interval values 0~62 Not involved None
Monitor
Environment
Interval values 0~254 Not involved None
Monitor
Environment
Interval values 0~1 Not involved None
Monitor
Environment
Interval values 1~30 Not involved None
Monitor
Environment
Interval values -20~80 Not involved degree Celsius
Monitor
Environment
Interval values -20~80 Not involved degree Celsius
Monitor
48V_DISABLE(-48
Environment Voltage
Interval values 0~100 Disabled), Not involved %
Monitor RES0(Reserved
Environment Sensor 0),
Interval values 0~100
RES1(Reserved
WS_DISABLE(Wat Not involved %
Monitor 48V_DISABLE~0,
Sensor
er 1),
-Immersed RES0~1, RES1~2,
Environment RES2(Reserved
Sensor Disabled),
Bit field type RES2~3, None
Monitor Sensor 2),
SS_DISABLE(Smo TS_DISABLE~4,
WS_DISABLE~0,
TS_DISABLE(Temp
g Sensor Disabled),
Environment HS_DISABLE~5
SS_DISABLE~1,
Bit field type erature Sensor
IS_DISABLE(Infrar None
Monitor Disabled), IS_DISABLE~2,
ed Sensor
-Disabled),
HS_DISABLE(Humi GS_DISABLE~3
Environment
Interval values 2147483648~2147
dity Sensor
GS_DISABLE(Gati Not involved degree Celsius
Monitor
483647
Disabled)
ng Sensor
Environment Disabled)
Interval values 0~100 Not involved %
Monitor
Environment
Character string 1~7 characters Not involved V
Monitor
Environment
Character string 1~7 characters Not involved None
Monitor
Environment
Character string 1~7 characters Not involved None
Monitor
Avail_0~0,
Avail_801(Fault,
Avail_1~1,
Communication
Avail_20~32,
lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
ication lost, In test),
Avail_501~1281,
Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Environment Avail_508~1288,
Character string lost, In test),
Alarm_2(Minor),
1~7 characters Alarm_2~2,
Not involved None
Monitor Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
Avail_521~1313,
Fault Management Character string 1~7 characters
Avail_c11(Power
Alarm_5(Major), Not involved
Alarm_5~5, None
Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
-Avail_d21(Starting
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost, In test),
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent,
CK), Communication BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
None Character string 0~63
ent, characters
Fault,
OARD), SFP(SFP) Not involved None
Communication
lost, In test)
None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None


None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None
Avail_0(Normal),
Avail_1(Fault),
None Interval values Avail_20(In
0~65535 test), Not involved None
Avail_21(Fault, In
test),
None Interval values 0~62
Avail_500(Starting Not involved None
up),
Avail_501(Starting
None Interval values 11~12 Not involved None
up, Fault),
Avail_504(Unconfig
None Interval values ured), 0 Not involved None
Avail_508(Inconsist
Environment ent),
Interval values 0~62
Avail_509(Inconsist Not involved None
Monitor
ent, Fault),
Environment Avail_520(Starting
Interval values 0~254 Not involved None
Monitor up,In test),
Avail_521(Starting
Environment up,
Interval values 0~1Fault, In test), Not involved None
Monitor Avail_524(Unconfig
Environment ured,In test),
Interval values 1~30
Avail_528(Inconsist Not involved None
Monitor WS_DISABLE(Wat
ent,In test),
er-Immersed
Avail_529(Inconsist
Environment WS_DISABLE~0,
Bit field type Sensor Disabled),
ent, Fault, In test), None
Monitor SS_DISABLE~1
SS_DISABLE(Smo
Avail_800(Commun
Environment g Sensor Disabled)
ication
Interval values 0~100 lost), Not involved
Avail_0~0, %
Monitor Avail_801(Fault,
Avail_1~1,
Environment Communication
Interval values -127~127 Avail_20~32,
Not involved degree Celsius
Monitor lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
Environment ication lost, In test),
Interval values -127~127 Avail_501~1281,
Not involved degree Celsius
Monitor Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Environment Avail_508~1288,
Interval values lost, In test),
Alarm_2(Minor),
0~4294967295 Alarm_2~2,
Not involved r/min
Monitor Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
DISABLE(Disable), DISABLE~0,
Avail_521~1313,
Fault Management Enumeration values Avail_c11(Power
Alarm_5(Major), Alarm_5~5, None
ENABLE(Enable) ENABLE~1
Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
Avail_c34(Unconfig
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
Avail_d01~3329,
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
Avail_d01(Starting
Avail_d09~3337,
None Character string 0~31 characters Not involved None

None Character string 0~259 characters Not involved None

None Character string 0~11 characters Not involved None

None Character string 0~23 characters Not involved None

None Character string LMPT(LMPT),


0~19 characters Not involved None
LBBP(LBBP), LMPT~1, LBBP~2,
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values UPEU(UPEU), UTRP~11, None
UTRP(UTRP), USCU~12,
USCU(USCU), UEIU~13
None Interval values 0~4294967295
UEIU(UEIU) Not involved None

CPU(CPU),
None Enumeration values CPU~0, DSP~1 None
DSP(DSP)
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
None Character string Master(Master),
0~255 characters Not involved None
NDD(NDD),
Master~0, NDD~1,
NCD(NCD),
NCD~2, NDC~3,
None Enumeration values CABINET(CABINE
NDC(NDC), None
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values CK),
EDL(EDL) BOARD~2, None
BOARD(BOARD), SUBBOARD~3,
SUBBOARD(SUBB SFP~4
None Character string 0~63 characters
OARD), SFP(SFP) Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

None Interval values 0~62 Not involved None

None Interval values 8,14 Not involved None


None Interval values 0 Not involved None
Avail_0(Normal),
Avail_1(Fault),
Environment Avail_20(In test),
Interval values 0~62 Not involved None
Monitor Avail_21(Fault, In
Environment test),
Interval values 0~254
Avail_500(Starting Not involved None
Monitor
up),
Environment Avail_501(Starting
Interval values 0~1 Not involved None
Monitor up, Fault),
Avail_504(Unconfig
Environment ured),
Interval values 1~30 Not involved None
Monitor Avail_508(Inconsist
Environment ent),
Interval values -40~10
Avail_509(Inconsist Not involved degree Celsius
Monitor
ent, Fault),
Environment Avail_520(Starting
Interval values 20~80 Not involved degree Celsius
Monitor up,In test),
WS_DISABLE(Wat
Avail_521(Starting
er-Immersed
Environment up, Fault, In test), WS_DISABLE~0,
Bit field type Sensor Disabled), None
Monitor Avail_524(Unconfig SS_DISABLE~1
SS_DISABLE(Smo
Environment ured,In
g Sensor test),
Disabled)
Interval values 0~2
Avail_528(Inconsist Not involved None
Monitor
ent,In test),
Environment Avail_529(Inconsist
DISABLE(Disable), DISABLE~0,
Enumeration values ent, Fault, In test), None
Monitor ENABLE(Enable) ENABLE~1
Avail_800(Commun
Environment ication lost),
Interval values -127~127 Not involved
Avail_0~0, degree Celsius
Monitor Avail_801(Fault,
Avail_1~1,
Environment Communication
Interval values -127~127 Avail_20~32,
Not involved degree Celsius
Monitor lost),
Avail_21~33,
Avail_820(Commun
Avail_500~1280,
Environment ication lost, In test),
Interval values -127~127 Avail_501~1281,
Not involved degree Celsius
Monitor Avail_821(Fault,
Alarm_0(Normal), Alarm_0~0,
Avail_504~1284,
Communication
Alarm_1(Warning), Alarm_1~1,
Environment Avail_508~1288,
Interval values lost, In test),
Alarm_2(Minor),
0~4294967295 Alarm_2~2,
Not involved r/min
Monitor Avail_509~1289,
Avail_c10(Power
Alarm_3(Minor), Alarm_3~3,
Avail_520~1312,
off),
Alarm_4(Major), Alarm_4~4,
Environment Avail_521~1313,
Interval values 0~4294967295
Avail_c11(Power
Alarm_5(Major), Not involved
Alarm_5~5, r/min
Monitor Avail_524~1316,
off, Fault),
Alarm_6(Major), Alarm_6~6,
Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Avail_529~1321, None
ed),
Alarm_8(Critical), Alarm_8~8,
Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Avail_821~2081,
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical), Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Avail_c14~3092,
Avail_c32(Uninstall
Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
Avail_c32~3122,
ed, Fault, In test),
Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Avail_c34~3124,
ured, Power off, In
Avail_d00~3328,
test),
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Avail_d04~3332,
ication lost),
Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Avail_d09~3337,
up, Fault,
Avail_d20~3360,
Communication
Avail_d21~3361,
lost),
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
Avail_d29~3369
Communication
lost),
Avail_d08(Inconsist
None Character string 0~23 characters Not involved None

None Character string LMPT(LMPT),


0~19 characters Not involved None
LBBP(LBBP), LMPT~1, LBBP~2,
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values UPEU(UPEU), UTRP~11, None
UTRP(UTRP), USCU~12,
USCU(USCU), UEIU~13
None Interval values 0~4294967295
UEIU(UEIU) Not involved None

CPU(CPU),
None Enumeration values CPU~0, DSP~1 None
DSP(DSP)
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
None Character string Master(Master),
0~255 characters Not involved None
NDD(NDD),
Master~0, NDD~1,
NCD(NCD),
NCD~2, NDC~3,
None Enumeration values CABINET(CABINE
NDC(NDC), None
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values CK),
EDL(EDL) BOARD~2, None
BOARD(BOARD), SUBBOARD~3,
SUBBOARD(SUBB SFP~4
None Character string 0~63 characters
OARD), SFP(SFP) Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

None Interval values 0~62 Not involved None

None Interval values 8,14 Not involved None

None Interval values 0 Not involved None

Environment
Interval values -99~70 Not involved degree Celsius
Monitor
Environment
Interval values -99~70 Not involved degree Celsius
Monitor
Environment
Interval values -99~70 Not involved degree Celsius
Monitor
Environment
Interval values 0~30 Not involved degree Celsius
Monitor
Environment
Interval values 0~30 Not involved degree Celsius
Monitor
Environment
Interval values 0~30 Not involved degree Celsius
Monitor
Environment
Interval values 0~30 Not involved degree Celsius
Monitor

None Interval values 0~62 Not involved None

None Interval values 7 Not involved None

None Interval values 0 Not involved None

Environment
Interval values 0~62 Not involved None
Monitor
Environment
Interval values 0~254 Not involved None
Monitor
Environment APM100(APM 100),
Interval values 0~1
APM200(APM 200), Not involved None
Monitor
APM30(APM 30),
Environment APM100~0,
Interval values EPS4890(EPS4890
1~30 Not involved None
Monitor APM200~1,
),
APM30~2,
EPS4815(EPS4815
Environment EPS4890~3,
Enumeration values ), None
Monitor EPS4815~4,
SC48200(SC48200
SC48200~5,
Environment ),
Interval values 60~300 EPS48200~7,
Not involved V
Monitor EPS48200(EPS482
TP48300A~8
00),
Environment TP48300A(TP4830
Interval values 60~300 Not involved V
Monitor 0A)
Environment
Interval values 350~556 Not involved 0.1V
Monitor
Environment
Interval values 580~600 Not involved 0.1V
Monitor
Environment DISABLE(Disable), DISABLE~0,
Enumeration values None
Monitor ENABLE(Enable) ENABLE~1
Environment
Interval values 350~556 Not involved 0.1V
Monitor
Environment
Interval values -20~20 Not involved degree Celsius
Monitor
Environment
Interval values 35~80 Not involved degree Celsius
Monitor
Environment
Interval values 0~50 Not involved %
Monitor
Environment
Interval values 50~100 Not involved %
Monitor
BT1_DISABLE(Batt
ery Temperature
Sensor 1 Disabled),
AH_DISABLE(Cabi
net Humidity BT1_DISABLE~0,
Environment WS_DISABLE(Wat
Sensor Disabled), AH_DISABLE~1,
Bit field type er-Immersed None
Monitor AT1_DISABLE(Cabi AT1_DISABLE~2,
Sensor Disabled),
net Temperature BT2_DISABLE~3
WS_DISABLE~0,
Environment SS_DISABLE(Smo
Sensor 1 Disabled),
Bit field type SS_DISABLE~1, None
Monitor g Sensor Disabled),
BT2_DISABLE(Batt GS_DISABLE~2
-GS_DISABLE(Gati
ery Temperature
Environment ng Sensor
Interval values 2147483648~2147
Sensor 2 Disabled) Not involved V
Monitor Disabled)
483647
Environment
Character string 1~7 characters Not involved V
Monitor
Environment
Character string 1~7 characters Not involved A
Monitor PowerOn(Power
on),
-
Environment LowVoltagePowerO
Interval values 2147483648~2147 Not involved degree Celsius
Monitor ff(Low
483647voltage PowerOn~0,
Environment power off),
Interval values 0~100 LowVoltagePowerO
Not involved %
Monitor MasterControlPowe
ff~1,
rOff(Master control
BoostCharging(Boo MasterControlPowe
Environment power off),
st-Charging),
Enumeration values rOff~2, None
Monitor HighTemperaturePo
FloatCharging(Float HighTemperaturePo
BoostCharging~0,
werOff(High
-Charging),
Environment werOff~3,
FloatCharging~1,
Enumeration values temperature power
ForceBoostChargin None
Monitor LowTemperaturePo
ForceBoostChargin
off),
g(ForceBoost-
PowerOn(Power werOff~4
g~2, Discharging~3
Environment LowTemperaturePo
Charging),
Character string on),
1~7 characters
werOff(Low Not involved A
Monitor Discharging(Discha
LowVoltagePowerO
temperature power
CurrentLimiting(Cur
rging) CurrentLimiting~0,
Environment ff(Low voltage
off) limiting),
rent PowerOn~0,
Enumeration values power off), NoCurrentLimiting~
LowVoltagePowerO None
Monitor NoCurrentLimiting(
MasterControlPowe 1
ff~1,
No current limiting)
Environment rOff(Master control MasterControlPowe
Enumeration values None
Monitor power off), rOff~2,
ManualPowerOff(M ManualPowerOff~3,
Environment anual
Interval values 0~100power off), HighTemperaturePo
Not involved %
Monitor HighTemperaturePo werOff~4
-werOff(High
Environment
Interval values 2147483648~2147
temperature power
CHARGE(Charging Not involved degree Celsius
Monitor
483647
off)
),
CHARGE~0,
Environment DISCHARGE(Disch
Enumeration values DISCHARGE~1, None
Monitor arging),
REC~2, END~3
REC(Recording),
Environment END(Finished)
Character string 1~7 characters Not involved A
Monitor
Environment
Character string 1~7 characters Not involved A
Monitor
-
Environment
Interval values 2147483648~2147 Not involved degree Celsius
Monitor
483647
None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Character string 0~18 characters Not involved None

None Character string 0~32 characters Not involved None


EltekEnergy(Eltek
Avail_524(Unconfig
Energy
ured,In test), Huawei~0,
Technology(Dong
Avail_528(Inconsist Emerson~1,
Guan)Ltd.),
ent,In test), Holdluck-ZYT~2,
Switchtec(Hangzho
Avail_529(Inconsist Power-One~3,
u Switchtec Power
ent, Fault,Co.,LTD.),
In test), Kehua~4,
Systems
Avail_800(Commun DeltaElectronics~5,
TycoElectronics(Tyc
None Character string ication
0~18 lost),
characters EltekEnergy~6,
Not involved None
o Electronics Avail_0~0,
Avail_801(Fault, Switchtec~7,
(Shang hai) Avail_1~1,
Communication TycoElectronics~8,
Co.,Ltd.), Avail_20~32,
None Enumeration values lost), ARTESYN~9, None
ARTESYN(Artesyn Avail_21~33,
SUCCEEDED(Succ
Avail_820(Commun
UNSUPPORTED(N CHROMA~10,
Technologies Avail_500~1280,
eeded),
ication
ot lost, In test),
Supported), LuckyValley~11,
UNSUPPORTED~0
None Enumeration values Co.,Ltd.), Avail_501~1281, None
BRDNOTREADY(T
Avail_821(Fault,
SUPPORTED(Supp
Alarm_0(Normal), ACBEL~12,
,Avail_504~1284,
SUPPORTED~1
Alarm_0~0,
CHROMA(Chroma
he board is
Communication
orted)
Alarm_1(Warning), Zippy~13,
Alarm_1~1,
Electronics),
DISABLE(Disable), Avail_508~1288,
DISABLE~0,
None Enumeration values unavailable),
lost, In test),
Alarm_2(Minor), GuoyaoElectronics
Alarm_2~2, None
LuckyValley(Lucky
ENABLE(Enable) SUCCEEDED~0,
Avail_509~1289,
ENABLE~1
UNSUPPORTED(T
Avail_c10(Power
Alarm_3(Minor), ~14, DPC~15,
Alarm_3~3,
Valley Technology BRDNOTREADY~1
Avail_520~1312,
he
off),PSU intelligent
Alarm_4(Major), GoldPower~16,
Alarm_4~4,
Co.,Ltd), ,
Avail_521~1313,
None Enumeration values shutdown is not
Avail_c11(Power
Alarm_5(Major), SungrowPowerSup
Alarm_5~5, None
ACBEL(Acbel UNSUPPORTED~2
Avail_524~1316,
supported
off, Fault), by the
Alarm_6(Major), ply~17, Ecom~18
Alarm_6~6,
Electronic Co.,Ltd), , BATNOTEXIST~3,
Avail_528~1320,
board),
Avail_c12(Uninstall
Alarm_7(Major), Alarm_7~7,
Fault Management Enumeration values Zippy(Zippy INTERNALERR~4
Avail_529~1321, None
BATNOTEXIST(The
ed),
Alarm_8(Critical), Alarm_8~8,
Technology corp.), Avail_800~2048,
battery does not
Avail_c13(Uninstall
Alarm_9(Critical), Alarm_9~9,
GuoyaoElectronics(
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values exist),
ed, Fault),
Alarm_10(Critical), Alarm_10~10, None
Shenzhen Guoyao
Disabled(Disabled) Avail_820~2080,
Disabled~1
INTERNALERR(Int
Avail_c14(Unconfig
Alarm_11(Critical), Alarm_11~11,
Electronics Avail_821~2081,
ernal error)
ured, Power off),
Alarm_12(Critical), Alarm_12~12,
Environment Technology Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical),
Co.,LTD.), Alarm_13~13, None
Monitor Avail_c11~3089,
off,In test),
Alarm_14(Critical),
DPC(Beijing Alarm_14~14,
Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical)
Dynamic Power Alarm_15~15
None Character string 0~2047 characters Avail_c13~3091,
Not involved None
off, Fault,
Science &In test), Avail_c14~3092,
Avail_c32(Uninstall
Technology Avail_c30~3120,
None Character string ed,In
0~31 test),
characters
Co.,Ltd.), Not involved None
Avail_c31~3121,
Avail_c33(Uninstall
GoldPower(Shenzh Avail_c32~3122,
ed, Fault,Power
en Gold In test),
Elec Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters
Tech Co.,Ltd), Not involved None
Avail_c34~3124,
ured, Power off, In
SungrowPowerSup Avail_d00~3328,
test),
ply(Sungrow Power
None Character string 0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Supply Co.,Ltd), Avail_d04~3332,
ication lost), Ecom
Ecom(Beijing Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters
Communications Not involved None
Avail_d09~3337,
up, Fault, Co. Ltd)
Technology Avail_d20~3360,
Communication
Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Avail_d24~3364,
Avail_d04(Unconfig
Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string 0~19 characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
lost),
FAN(FAN), FAN~3, UPEU~4,
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
ent, Communication
UTRP(UTRP), USCU~12,
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
Avail_d21(Starting
-
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost, In test),
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent, Communication
CK), BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
ent, Fault,
OARD), SFP(SFP)
Communication
lost, In test)
None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

None Interval values 0~62 Not involved None

None Interval values 7 Not involved None

None Interval values 0 Not involved None

DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 1~1000 Not involved 0.1kVA

None Character string 1~7 characters Not involved cm

None Character string 1~7 characters Not involved A

None Interval values 0~4294967295 Not involved h

None Interval values 0~62 Not involved None

None Interval values 7 Not involved None

None Interval values 0 Not involved None

INNER(Inner), INNER~0,
None Enumeration values None
OUTER(Outer) OUTER~1

None Interval values 30~240 Not involved day

None Interval values 433~576 Not involved 0.1V

None Interval values 5~5000 Not involved Ah


None Interval values 5~25 Not involved 0.01

None Interval values 432~575 Not involved 0.1V

DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 40~70 Not involved degree Celsius

DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 350~556 Not involved 0.1V

None Interval values 0~500 Not involved mV/degree Celsius

None Interval values -20~20 Not involved degree Celsius

None Interval values 35~80 Not involved degree Celsius

None Interval values 1~2 Not involved None


VRLA_BAT(VRLA
VRLA_BAT~2,
None Enumeration values Battery), LI_BAT(Li- None
LI_BAT~3
Ion Battery)
None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None


None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

2000-01-01~2099-
None Composite type Not involved None
12-31

None Interval values 5~5000 Not involved Ah

None Interval values 0~62 Not involved None

None Interval values 7 Not involved None

None Interval values 0 Not involved None

None Interval values 1~5000 Not involved 0.01h

None Interval values 1~5000 Not involved 0.01h

None Interval values 1~5000 Not involved 0.01h

None Interval values 1~5000 Not involved 0.01h

None Interval values 1~5000 Not involved 0.01h

None Interval values 1~5000 Not involved 0.01h

None Interval values 1~5000 Not involved 0.01h

None Interval values 1~5000 Not involved 0.01h

None Interval values 1~5000 Not involved 0.01h


None Interval values 1~5000 Not involved 0.01h

None Interval values 80~100 Not involved %

None Interval values 170~220 Not involved 0.01V/Cell

None Interval values 1~50 Not involved None

None Interval values 1~100 Not involved h

None Interval values 1~240 Not involved min


NOAUTOTEST(No
Auto Test),
None Interval values 400~540
PERIOD(Period Not involved 0.1V
NOAUTOTEST~0,
Auto Test),
PERIOD~1,
POWERCUT(Powe
None Enumeration values POWERCUT~2, None
r Off Auto Test),
PERIODPOWERC
PERIODPOWERC
UT~3
None Interval values UT(Period
30~240 and Not involved day
Power Off Auto
STANDARD(Standa
Test)
None Interval values rd Test),
1~60 Not involved day
SIMPLE(Simple STANDARD~0,
Test), SIMPLE~1,
None Enumeration values BelowEndVol(Lower
TIMER(Period TIMER~2, None
Than
Test), End Voltage), PWROFF~3,
2000-01-01
OverTime(Test
PWROFF(Power NONE~4
None Composite type 00:00:00~2038-12-
Timeout),
Cut Test), Not involved None
31 23:59:59 Test) BelowEndVol~0,
CurrRecover(Power
NONE(None OverTime~1,
Resume Stop
None Enumeration values None(No result), CurrRecover~2, None
Power Drop Auto
Normal(Battery ManualEnd~3,
Test),
normal), AlmEnd~4
None~0, Normal~1,
None Enumeration values ManualEnd(Manual None
PreAlm(Battery
Stop Test), pre- PreAlm~2, Alm~3
alarm), Alm(Battery
AlmEnd(Alarm Stop
None Interval values alarm)
0~100
Test) Not involved %

None Character string 1~7 characters Not involved h

None Character string 1~7 characters Not involved V

None Character string 1~7 characters Not involved A

None Interval values 0~4294967295 Not involved Ah


-
None Interval values 2147483648~2147 Not involved degree Celsius
483647
None Interval values 0~62 Not involved None

None Interval values 7 Not involved None

None Interval values 1~6 Not involved None


ent, Fault, In test),
Power(Dong guan)
Avail_800(Commun
LTD.),
ication lost),
NORMAL(Normal),
EltekEnergy(Eltek Avail_0~0,
Avail_801(Fault,
COMMUNICATEFAI
Energy Avail_1~1,
Communication
LED(Communicatio Huawei~0,
NORMAL~0,
Technology(Dong Avail_20~32,
lost),
n failed), Emerson~1,
COMMUNICATEFAI
Guan)Ltd.), Avail_21~33,
Avail_820(Commun
SHUTDOWN(Shut Holdluck-ZYT~2,
LED~1,
Switchtec(Hangzho Avail_500~1280,
ication
down), lost, In test), Power-One~3,
SHUTDOWN~2,
None Enumeration values u Switchtec Power Avail_501~1281, None
Avail_821(Fault,
FAULT(Fault),
Alarm_0(Normal), Kehua~4,
FAULT~3,
Alarm_0~0,
Systems Co.,LTD.), Avail_504~1284,
Communication
PROTECT(Fault),
Alarm_1(Warning), DeltaElectronics~5,
PROTECT~4,
Alarm_1~1,
TycoElectronics(Tyc Avail_508~1288,
None Character string lost, Incharacters
test),
UNCONFIGURED(
Alarm_2(Minor),
0~18 EltekEnergy~6,
UNCONFIGURED~
Alarm_2~2,
Not involved None
o Electronics Avail_509~1289,
Avail_c10(Power
Unconfigured),
Alarm_3(Minor), Switchtec~7,
5, ILLEGAL~6
Alarm_3~3,
(Shang hai) Avail_520~1312,
off),
ILLEGAL(Unconfigu
Alarm_4(Major), TycoElectronics~8,
Alarm_4~4,
Co.,Ltd.), Avail_521~1313,
None Enumeration values Avail_c11(Power
red)
Alarm_5(Major), ARTESYN~9,
Alarm_5~5, None
ARTESYN(Artesyn Avail_524~1316,
off, Fault),
Alarm_6(Major), CHROMA~10,
Alarm_6~6,
Technologies Avail_528~1320,
Avail_c12(Uninstall
Alarm_7(Major), LuckyValley~11,
Alarm_7~7,
Fault Management Enumeration values Co.,Ltd.), Avail_529~1321, None
ed),
Alarm_8(Critical), ACBEL~12,
Alarm_8~8,
CHROMA(Chroma Avail_800~2048,
Avail_c13(Uninstall
Alarm_9(Critical), Zippy~13,
Alarm_9~9,
Electronics),
Enabled(Enabled), Avail_801~2049,
Enabled~0,
None Enumeration values ed, Fault),
Alarm_10(Critical), GuoyaoElectronics
Alarm_10~10, None
LuckyValley(Lucky
Disabled(Disabled) Avail_820~2080,
Disabled~1
Avail_c14(Unconfig
Alarm_11(Critical), ~14, DPC~15,
Alarm_11~11,
Valley Technology Avail_821~2081,
ured, Power off),
Alarm_12(Critical), GoldPower~16,
Alarm_12~12,
Environment Co.,Ltd), Avail_c10~3088,
Enumeration values Avail_c30(Power
Alarm_13(Critical), SungrowPowerSup
Alarm_13~13, None
Monitor ACBEL(Acbel Avail_c11~3089,
off,In test),
Alarm_14(Critical), ply~17, Ecom~18
Alarm_14~14,
Electronic Co.,Ltd), Avail_c12~3090,
Avail_c31(Power
Alarm_15(Critical) Alarm_15~15
None Character string Zippy(Zippy
0~2047 characters Avail_c13~3091,
Not involved None
off, Fault, In test),
Technology corp.), Avail_c14~3092,
Avail_c32(Uninstall
GuoyaoElectronics( Avail_c30~3120,
None Character string ed,In
0~31 test),
characters Not involved None
Shenzhen Guoyao Avail_c31~3121,
Avail_c33(Uninstall
Electronics Avail_c32~3122,
ed, Fault, In test),
Technology Avail_c33~3123,
None Character string Avail_c34(Unconfig
0~31 characters Not involved None
Co.,LTD.), Avail_c34~3124,
ured, Power off, In
DPC(Beijing Avail_d00~3328,
test),
None Character string Dynamic Power
0~259 characters Avail_d01~3329,
Not involved None
Avail_d00(Commun
Science & Avail_d04~3332,
ication lost),
Technology Avail_d08~3336,
None Character string Avail_d01(Starting
0~11 characters Not involved None
Co.,Ltd.), Avail_d09~3337,
up, Fault,
GoldPower(Shenzh Avail_d20~3360,
Communication
en Gold Power Elec Avail_d21~3361,
None Character string lost),
0~23 characters Not involved None
Tech Co.,Ltd), Avail_d24~3364,
Avail_d04(Unconfig
SungrowPowerSup Avail_d28~3368,
ured,
LMPT(LMPT),
None Character string ply(Sungrow
0~19 Power
characters Avail_d29~3369
Not involved None
Communication
LBBP(LBBP), LMPT~1, LBBP~2,
Supply Co.,Ltd),
lost),
FAN(FAN), FAN~3, UPEU~4,
Ecom(Beijing Ecom
None Enumeration values Avail_d08(Inconsist
UPEU(UPEU), UTRP~11, None
Communications
ent, Communication
UTRP(UTRP), USCU~12,
Technology Co. Ltd)
lost),
USCU(USCU), UEIU~13
None Interval values Avail_d09(Inconsist
0~4294967295
UEIU(UEIU) Not involved None
ent, Fault,
Communication
CPU(CPU),
None Enumeration values lost), CPU~0, DSP~1 None
DSP(DSP)
Avail_d20(Starting
-
up, Communication
None Interval values 2147483648~2147 Not involved degree Celsius
lost,In test),
483647
Avail_d21(Starting
-
None Interval values up, Fault,
2147483648~2147 Not involved degree Celsius
Communication
483647
lost, In test),
None Character string Master(Master),
0~255 characters Not involved None
Avail_d24(Unconfig
NDD(NDD),
ured, Master~0, NDD~1,
NCD(NCD),
Communication
CABINET(CABINE NCD~2, NDC~3,
None Enumeration values NDC(NDC), None
lost, In test),
T), NEC~4, EUL~5,
CABINET~0,
NEC(NEC),
Avail_d28(Inconsist
SUBRACK(SUBRA EDL~6
SUBRACK~1,
EUL(EUL),
None Enumeration values ent, Communication
CK), BOARD~2, None
EDL(EDL)
lost, In test),
BOARD(BOARD), SUBBOARD~3,
Avail_d29(Inconsist
SUBBOARD(SUBB SFP~4
None Character string 0~63Fault,
ent,
OARD), characters
SFP(SFP) Not involved None
Communication
lost, In test)
None Character string 0~63 characters Not involved None
None Character string 0~63 characters Not involved None

None Character string 0~63 characters Not involved None

None Character string 1~39 characters Not involved None


Normal(Normal),
Normal~0, Fault~1,
Fault(Fault),
None Enumeration values Timeout~2, None
Timeout(Timeout),
NULL~4294967295
NULL(NULL)
None Interval values 0~65535 Not involved None

None Interval values 0~65535 Not involved None

None Interval values 0~62 Not involved None

None Interval values 40~59 Not involved None

None Interval values 0 Not involved None

None Interval values 0~5 Not involved None

Environment
Character string 0~50 characters Not involved None
Monitor
Environment
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Monitor

None Interval values 0~62 Not involved None

0~1,7~8,11~12,14,4
None Interval values Not involved None
0~254

None Interval values 0,18~19 Not involved None

None Interval values 0~35 Not involved None

Environment
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Monitor
Environment
Interval values 65033~65233 Not involved None
Monitor
BOOL(Digital Port),
Environment
Enumeration values VALUE(Analog BOOL~0, VALUE~1 None
Monitor
Port)
HIGH(High
Environment
Enumeration values Voltage), LOW(Low HIGH~0, LOW~1 None
Monitor
Voltage)
Environment
Interval values -99999~999999 Not involved 0.01
Monitor
Environment
Interval values -99999~999999 Not involved 0.01
Monitor
VOLTAGE(Voltage
Environment Type), VOLTAGE~0,
Enumeration values None
Monitor CURRENT(Current CURRENT~1
Type)
Environment
Interval values -99999~999999 Not involved 0.01
Monitor
Environment
Interval values -99999~999999 Not involved 0.01
Monitor
GMT-1200(GMT-
Environment 12:00), GMT-
Interval values 0~999999 Not involved 0.01V or 0.01mA
Monitor 1100(GMT-11:00),
Remote Electrical GMT-1000(GMT-
Interval values 0~999999
10:00), GMT- Not involved 0.01V or 0.01mA
Tilt Control
0930(GMT-09:30),
NONE(Verify
GMT-0900(GMT-
None Enumeration values None), PEER(Verify NONE~0, PEER~1 None
09:00), GMT-
Peer Certificate)
0800(GMT-08:00),
None IP address type GMT-0700(GMT-
Valid IP address Not involved None
07:00), GMT-
0600(GMT-06:00),
None Interval values 1~525600
GMT-0500(GMT- Not involved min
05:00), GMT-
0430(GMT-04:30),
123~5999,6100~65
None Interval values GMT-0400(GMT- Not involved None
534
04:00), GMT-
GMT-1200~0, GMT-
None Enumeration values 0330(GMT-03:30),
OFF(Off), ON(On) OFF~0,
1100~4, ON~1
GMT- None
GMT-0300(GMT-
1000~8, GMT-
03:00), GMT-
IPV4(IPv4),
None Enumeration values 0930~10, GMT-
IPV4~0, IPV6~1 None
0200(GMT-02:00),
IPV6(IPv6) 0900~12, GMT-
GMT-0100(GMT-
0800~16, GMT-
01:00), GMT(GMT),
None IP address type Valid IP address 0700~20, GMT-
Not involved None
GMT+0100(GMT+0
PLAIN(Plain), 0600~24,
PLAIN~0, GMT-
1:00),
DES_S(DES_S), 0500~28,
DES_S~1,GMT-
None Enumeration values GMT+0200(GMT+0
DES_N(DES_N), None
0430~30,
DES_N~2,GMT-
2:00),
DES_A(DES_A), 0400~32,
DES_A~3,GMT-
MD5~4
GMT+0300(GMT+0
MD5(MD5) 0330~34, GMT-
None Character string 1~16 characters
3:00), Not involved None
0300~36, GMT-
GMT+0330(GMT+0
0200~40, GMT-
3:30),
None Interval values 1~4294967295 0100~44, GMT~48,
Not involved None
GMT+0400(GMT+0
GMT+0100~52,
4:00),
Slaver(Slave), GMT+0200~56,
None Enumeration values GMT+0430(GMT+0 Slaver~0, Master~1 None
Master(Master) GMT+0300~60,
4:30),
GMT+0330~62,
GMT+0500(GMT+0
GMT+0400~64,
None Enumeration values 5:00), None
GMT+0430~66,
GMT+0530(GMT+0
NO(No), GMT+0500~68,
5:30), YES(Yes), NO~0, YES~1,
None Enumeration values JAN(January),
ALL(Always on GMT+0530~70, None
GMT+0545(GMT+0
DATE(Date mode), ALL~2
FEB(February),
DST) GMT+0545~71,
5:45),
WEEK(Week
MAR(March), GMT+0600~72,
DATE~0, WEEK~1,
None Enumeration values GMT+0600(GMT+0
mode), None
APR(April), GMT+0630~74,
JAN~1, FEB~2,
DATEWEEK~2
6:00),
DATEWEEK(Date
MAY(May), GMT+0700~76,
MAR~3, APR~4,
GMT+0630(GMT+0
and week mode)
JUN(June), GMT+0800~80,
MAY~5, JUN~6,
None Enumeration values 6:30), None
JUL(July), GMT+0845~83,
JUL~7, AUG~8,
GMT+0700(GMT+0
AUG(August), GMT+0900~84,
SEP~9, OCT~10,
7:00),
None Interval values SEP(September),
1~31 GMT+0930~86,
NOV~11, DEC~12
Not involved None
GMT+0800(GMT+0
LAST(Last),
OCT(October), GMT+1000~88,
LAST~0, FIRST~1,
8:00),
FIRST(First),
NOV(November), GMT+1030~90,
SECOND~2,
None Enumeration values GMT+0845(GMT+0
MON(Monday),
SECOND(Second), None
DEC(December) GMT+1100~92,
THIRD~3,
8:45),
TUE(Tuesday),
THIRD(Third), GMT+1130~94,
MON~1,
FOURTH~4 TUE~2,
GMT+0900(GMT+0
WED(Wednesday),
FOURTH(Fourth) GMT+1200~96,
WED~3, THU~4,
None Enumeration values 9:00),
THU(Thursday), None
GMT+1245~99,
FRI~5, SAT~6,
GMT+0930(GMT+0
FRI(Friday), GMT+1300~100,
SUN~7
9:30),
SAT(Saturday),
None Composite type 00:00:00~23:59:59 GMT+1400~104,
Not involved None
GMT+1000(GMT+1
SUN(Sunday) CUSTOM~200
0:00),
GMT+1030(GMT+1
0:30),
GMT+1100(GMT+1
1:00),
GMT+1130(GMT+1
1:30),
JAN(January),
DATE(Date mode),
FEB(February),
WEEK(Week
MAR(March), DATE~0, WEEK~1,
None Enumeration values mode),
APR(April), JAN~1, FEB~2, None
DATEWEEK~2
DATEWEEK(Date
MAY(May), MAR~3, APR~4,
and week mode)
JUN(June), MAY~5, JUN~6,
None Enumeration values None
JUL(July), JUL~7, AUG~8,
AUG(August), SEP~9, OCT~10,
None Interval values SEP(September),
1~31 NOV~11, DEC~12 None
Not involved
LAST(Last),
OCT(October), LAST~0, FIRST~1,
FIRST(First),
NOV(November),
MON(Monday), SECOND~2,
None Enumeration values SECOND(Second),
DEC(December) None
TUE(Tuesday), THIRD~3,
THIRD(Third), MON~1, TUE~2,
WED(Wednesday), FOURTH~4
FOURTH(Fourth) WED~3, THU~4,
None Enumeration values THU(Thursday), None
FRI~5, SAT~6,
FRI(Friday),
SUN~7
SAT(Saturday),
None Composite type 00:00:00~23:59:59
SUN(Sunday) Not involved None

None Interval values -120~120 Not involved min

None Interval values -720~840 Not involved min

2000-01-01~2033-
None Composite type Not involved None
12-31

None Composite type 00:00:00~23:59:59 Not involved None

None Composite type None Not involved None


NTP(NTP),
NTP~0, GPS~1,
None Enumeration values GPS(GPS), None
NONE~2
NONE(None)
None Character string 0~30 characters Not involved None

None Interval values 0~3 Not involved None

None
Service based inter- Interval values 10~254 Not involved None
RAT handover to
UTRAN
Interval values 0~9 Not involved None
Service based inter-
RAT handover to QCI1(QCI 1),
GERAN
None Interval values QCI2(QCI
0~3 2), Not involved None
QCI3(QCI 3), QCI1~1, QCI2~2,
QCI4(QCI 4), QCI3~3, QCI4~4,
None based inter- Enumeration values QCI5(QCI 5),
Service QCI5~5, QCI6~6, None
RAT handover to QCI6(QCI 6), QCI7~7, QCI8~8,
UTRAN QCI7(QCI 7), QCI9~9
Interval values 0~9
QCI8(QCI 8), Not involved None
Service based inter-
RAT handover to QCI9(QCI 9)
GERAN
None
CS Fallback to Interval values 0~3 Not involved None
UTRAN
UTRAN~0,
CS Fallback to UTRAN, GERAN,
CS Fallback to Enumeration values GERAN~1, None
GERAN CDMA2000
UTRAN CDMA2000~2
UTRAN~0,
CS Fallback to
CS Fallback 1xRTT
CDMA2000 to UTRAN, GERAN, GERAN~1,
CS Fallback to Enumeration values None
GERAN CDMA2000, NULL CDMA2000~2,
UTRAN
CS Fallback to UTRAN~0,
NULL~3
CS Fallback 1xRTT
CDMA2000 to UTRAN, GERAN, GERAN~1,
Enumeration values None
GERAN CDMA2000, NULL CDMA2000~2,
CS Fallback to NULL~3
CDMA2000 1xRTT
CS Fallback to
UTRAN
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
LoCation
CS Fallback to
Services(LCS)
GERAN
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
LoCation
CS Fallback to
Services(LCS)
CDMA2000 1xRTT
Intra-LTE Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
LoCation Load
Balancing
Services(LCS)
Inter-RAT Load
Intra-LTE Interval values 0~255 Not involved None
Sharing toLoad
UTRAN
Balancing
Inter-RAT Load
Inter-RAT
Sharing toLoad
GERAN LTE, UTRAN, LTE~0, UTRAN~1,
Intra-LTE Enumeration values None
Sharing toLoad
UTRAN GERAN GERAN~2
Balancing
Inter-RAT Load
Inter-RAT
Sharing toLoad
GERAN 0~39649,65336~65
Intra-LTE Interval values Not involved None
Sharing toLoad
UTRAN 535
Balancing
Inter-RAT Load
Inter-RAT
Sharing toLoad
GERAN Interval values 0~7 Not involved None
Sharing to UTRAN
Inter-RAT Load
Sharing
None to GERAN
Service based inter- Interval values 0~3 Not involved None
RAT handover to
UTRAN
Service Interval values 0~9 Not involved None
Service based
based inter-
inter-
RAT
RAT handover
handover to
to NO_HO, NO_HO~0,
UTRAN
GERAN Enumeration values PERMIT_HO, PERMIT_HO~1, None
Service based inter-
MUST_HO MUST_HO~2
RAT handover to
GERAN
None Interval values 1~256 Not involved None

FALSE(FALSE),
DRX
Intra-LTE Load Enumeration values FALSE~0, TRUE~1 None
TRUE(TRUE)
Balancing
Inter-RAT Load NOT_CFG(NOT_C NOT_CFG~0,
Intra-LTE Enumeration values None
Sharing to Load
UTRAN FG), CFG(CFG) CFG~1
Balancing
Inter-RAT Load
Inter-RAT
Sharing toLoad
GERAN Interval values 0~255 Not involved None
Sharing to UTRAN
Inter-RAT Load
Sharing
Integrity to GERAN
Protection Interval values 0,10~600 Not involved s

Integrity Protection Interval values 0,128~4294967295 Not involved None

Integrity Protection Enumeration values OFF(Off),


NULL(NULL ON(On) OFF~0, ON~1 None
Algorithm),
Encryption AES
Snow3G(SNOW 3G NULL~0,
Encryption SNOW Enumeration values NULL(NULL None
Algorithm), Snow3G~1, AES~2
3G Algorithm),
Encryption AES AES(AES
Snow3G(SNOW 3G NULL~0,
Encryption SNOW Enumeration values Algorithm)
NULL(NULL None
Algorithm), Snow3G~1, AES~2
3G Algorithm),
Encryption AES AES(AES
Snow3G(SNOW 3G NULL~0,
Encryption SNOW Enumeration values Algorithm)
NULL(NULL None
Algorithm), Snow3G~1, AES~2
3G Algorithm),
AES(AES
Snow3G(SNOW 3G NULL~0,
Integrity Protection Enumeration values Algorithm)
NULL(NULL None
Algorithm), Snow3G~1, AES~2
Algorithm),
AES(AES
Snow3G(SNOW 3G NULL~0,
Integrity Protection Enumeration values Algorithm)
NULL(NULL None
Algorithm), Snow3G~1, AES~2
Algorithm),
AES(AES
Snow3G(SNOW 3G NULL~0,
Integrity Protection Enumeration values Algorithm) None
Algorithm), Snow3G~1, AES~2
AES(AES
Algorithm)
Mobility
Management X2_OVER_M2000(
Coverage Based X2SonLink is set up
Intra-frequency over M2000), X2_OVER_M2000~
Enumeration values None
Handover X2_OVER_S1(X2S 0, X2_OVER_S1~1
Coverage Based
Basic Scheduling onLink is set up
Inter-frequency
Enhanced Enumeration values over S1) ON(On)
OFF(Off), OFF~0, ON~1 None
Basic Scheduling
Handover
Scheduling LCG_PROFILE_0(L LCG_PROFILE_0~
Enhanced
CG_PROFILE_0), 0,
Scheduling Enumeration values None
LCG_PROFILE_1(L LCG_PROFILE_1~
Logical Channel
RObust Header CG_PROFILE_1)
U_MODE(Unidirecti 1
Management
Compression Enumeration values OFF(Off),
onal ON(On)
Mode), OFF~0, ON~1 None
(ROHC) O_MODE(Bi-
RObust Header Profile0x0001(Profil U_MODE~1,
directional
Compression Enumeration values e0x0001), O_MODE~2, None
Optimistic Mode),
(ROHC) Profile0x0002(Profil R_MODE~3
Profile0x0001~0,
RObust Header R_MODE(Bi-
e0x0002),
Directional Reliable Profile0x0002~1,
Compression Bit field type None
Profile0x0003(Profil
Mode) Profile0x0003~2,
(ROHC)
e0x0003), Profile0x0004~3
RRC Connection Profile0x0004(Profil
Interval values 1~16
min5(5), min10(10), Not involved s
Management e0x0004) min5~0, min10~1,
Mobility min20(20),
min20~2, min30~3,
Management min30(30),
ms50(50),
Enumeration values min60~4,ms100~1,
ms50~0, min
Cell Selection and min60(60),
ms100(100),
Mobility min120~5,
ms150~2,
Re-selection min120(120),
ms150(150),
Management ms100(100), min180~6
ms200~3,
ms100~0,
Enumeration values min180(180)
ms200(200), ms
Cell Selection and ms200(200), ms500~4,
ms200~1,
Mobility ms500(500),
Re-selection ms500(500), ms1000~5,
ms500~2,
Management ms1000(1000),
Enumeration values ms1000(1000),
min5(5), min10(10), ms2000~6
ms1000~3, ms
Cell Selection and ms2000(2000) min5~0, min10~1,
Mobility ms2000(2000),
min20(20), ms2000~4,
Re-selection min20~2, min30~3,
Management ms4000(4000),
min30(30), ms4000~5,
Enumeration values ms8000(8000) min60~4,
ms8000~6 min
Cell Selection and min60(60),
min120~5,
Re-selection min120(120),
RRC Connection min180~6
Interval values min180(180)
0~3600 Not involved s
Management

None Interval values 2000~60000 Not involved ms

None Interval values 2000~60000 Not involved ms

None Interval values 2000~60000 Not involved ms

None Interval values 2000~60000 Not involved ms

None Interval values 0,2000~60000 Not involved ms

None Interval values 5~3600 Not involved s

None Interval values 0~11 Not involved None


DB_6_P_A(-6 dB),
Dynamic Downlink DB_4DOT77_P_A(- DB_6_P_A~0,
Enumeration values 4.77
OFF(Off),
dB), ON(On) OFF~0, ON~1
DB_4DOT77_P_A~ None
Power Allocation
DB_3_P_A(-3 dB), 1, DB_3_P_A~2,
Dynamic Downlink DB_1DOT77_P_A(- DB_1DOT77_P_A~
Enumeration values dB
Power Allocation 1.77 dB), 3, DB0_P_A~4,
DB0_P_A(0 dB), DB1_P_A~5,
None Interval values DB1_P_A(1
0~11 dB), DB2_P_A~6,
Not involved None
DB2_P_A(2 dB), DB3_P_A~7
DB3_P_A(3 dB)
DRX Interval values 0~1000 Not involved None
DRX Interval values 0~1000 Not involved None

DRX Interval values 0~2000 Not involved None

UU_FC0_FILTER_
DRX Interval values 0~2000
COEFF(UU_FC0_F Not involved None
ILTER_COEFF),
DRX Interval values UU_FC1_FILTER_
0~2000 Not involved None
COEFF(UU_FC1_F
ILTER_COEFF),
DRX Interval values 0~2000
UU_FC2_FILTER_ Not involved None
COEFF(UU_FC2_F
UU_FC0_FILTER_
ILTER_COEFF),
DRX Interval values 2~300 COEFF~0,
Not involved 20ms
UU_FC3_FILTER_
UU_FC1_FILTER_
COEFF(UU_FC3_F
COEFF~1,
None Interval values ILTER_COEFF),
0~11 Not involved None
UU_FC2_FILTER_
UU_FC4_FILTER_
UU_DISABLE(Disa COEFF~2,
COEFF(UU_FC4_F
Uplink Power ble), UU_DISABLE~0,
UU_FC3_FILTER_
Enumeration values ILTER_COEFF), None
Control UU_ENABLE(Enabl UU_ENABLE~1
COEFF~3,
UU_FC5_FILTER_
-105,-90,-75,-60,-
e) UU_FC4_FILTER_
Uplink Power COEFF(UU_FC5_F
45,-30,-
Interval values COEFF~4,
Not involved 0.1dB
Control ILTER_COEFF),
15,0,15,30,45,60,75
PSF1(1 subframe),
-30,-20,- UU_FC5_FILTER_
UU_FC6_FILTER_
,90,105,120
PSF2(2 subframes),
Uplink Power 10,0,10,20,30,40,50 COEFF~5,
Interval values COEFF(UU_FC6_F
PSF3(3 subframes), Not involved 0.1dB
Control ,60,70,80,90,100,11 UU_FC6_FILTER_
ILTER_COEFF),
PSF4(4
PSF1(1 subframes),
0,120 subframe),
UU_FC7_FILTER_
COEFF~6,
Uplink Power PSF5(5
PSF2(2 subframes),
subframes), UU_FC7_FILTER_
Enumeration values COEFF(UU_FC7_F
PSF6(6 subframes), None
Control PSF3(3 subframes), COEFF~7,
ILTER_COEFF),
PSF8(8 subframes),
PSF4(4 subframes), UU_FC8_FILTER_
UU_FC8_FILTER_
PSF10(10
None Interval values 0~11
PSF5(5 subframes), COEFF~8,
Not involved None
COEFF(UU_FC8_F
SF10(10
subframes),
PSF6(6 subframes), UU_FC9_FILTER_
ILTER_COEFF),
subframes),
PSF20(20
PSF8(8 subframes), COEFF~9,
PSF1~0, PSF2~1,
DRX Interval values UU_FC9_FILTER_
SF20(20
0~9
subframes), PSF1~0,
Not PSF2~1,
involved None
PSF10(10 UU_FC11_FILTER_
PSF3~2, PSF4~3,
COEFF(UU_FC9_F
subframes),
PSF30(30 PSF3~2, PSF4~3,
subframes), COEFF~10,
PSF5~4, PSF6~5,
ILTER_COEFF),
SF32(32
subframes), PSF5~4, PSF6~5,
PSF20(20 UU_FC13_FILTER_
PSF8~6, PSF10~7,
DRX Enumeration values UU_FC11_FILTER_
OFF(Off),
subframes),
PSF40(40 ON(On) OFF~0, ON~1
PSF8~6, PSF10~7, None
subframes), COEFF~11,
PSF20~8,
COEFF(UU_FC11_
SF40(40
subframes), PSF20~8,
PSF30(30 UU_FC15_FILTER_
PSF30~9,
FILTER_COEFF),
SF2(2 subframes),
subframes),
PSF50(50 PSF30~9,
DRX Enumeration values subframes), COEFF~12,
PSF40~10, subframe
UU_FC13_FILTER_
SF5(5
SF64(64subframes),
subframes), PSF40~10,
PSF40(40 UU_FC17_FILTER_
PSF50~11,
COEFF(UU_FC13_
SF8(8 subframes),
subframes),
PSF60(60 PSF50~11,
sf1(1 subframe),
subframes), COEFF~13,
SF10~0, SF20~1,
PSF60~12,
DRX Enumeration values FILTER_COEFF),
SF10(10
SF80(80
subframes), PSF60~12, subframe
sf2(2 subframes),
PSF50(50 UU_FC19_FILTER_
SF32~2,
PSF80~13, SF40~3,
UU_FC15_FILTER_
subframes),
PSF80(80 PSF80~13,
DRX sf4(4 subframes),
subframes), COEFF~14
sf1~0,
SF64~4,sf2~1,
PSF100~14, sf4~2,
SF80~5,
COEFF(UU_FC15_
SF16(16
SF128(128
subframes), PSF100~14,
DL sf6(6 subframes),
PSF60(60
FILTER_COEFF), sf6~3, sf8~4,
SF128~6,
PSF200~15,
Enumeration values subframes),
PSF100(100 PSF200~15 subframe
Asynchronization sf8(8 subframes),
subframes),
UU_FC17_FILTER_ sf16~5,
SF160~7,sf24~6,
PSF300~16,
SF20(20
SF160(160
subframes),
HARQ sf16(16
PSF80(80 subframes),
COEFF(UU_FC17_ sf33~7
SF256~8,
PSF500~17,
subframes),
PSF200(200
DRX Enumeration values sf24(24 subframes),
subframes),
FILTER_COEFF), SF320~9,
PSF750~18, subframe
SF32(32
SF256(256
subframes), SF2~0, SF5~1,
sf33(33 subframes)
PSF100(100
UU_DISABLE(Disa
UU_FC19_FILTER_ SF512~10,
PSF1280~19,
subframes),
PSF300(300 SF8~2, SF10~3,
subframes),
ble),
COEFF(UU_FC19_
SF40(40 SF640~11,
PSF1920~20,
UU_DISABLE~0,
SF16~4, SF20~5,
DRX Enumeration values SF320(320
subframes), None
PSF200(200
UU_ENABLE(Enabl
FILTER_COEFF)
subframes), SF1024~12,
PSF2560~21
UU_ENABLE~1
SF32~6, SF40~7,
PSF500(500
subframes) SF1280~13,
e)
SF64(64
SF512(512 SF64~8, SF80~9,
subframes), SF2048~14,
DRX Enumeration values subframes),
PSF750(750 SF128~10, subframe
SF80(80 SF2560~15
SF160~11,
PS Inter-RAT SF640(640
subframes),
subframes),
PSF1280(1280 SF256~12,
Mobility
DRX between E- Interval values 1~16 Not involved None
SF128(128
SF1024(1024
subframes), SF320~13,
UTRAN and
subframes),
PSF1920(1920 SF512~14,
UTRAN
3GPP R8
Interval values SF160(160
SF1280(1280
subframes),
0~11 SF640~15
Not involved None
PS Inter-RAT
Specifications subframes),
PSF2560(2560
Mobility between E-
SF256(256
SF2048(2048
subframes)
UTRAN and
Interval values subframes),
0~9 Not involved None
GERAN
SF320(320
SF2560(2560
PS Inter-RAT
subframes),
subframes)
Mobility between E-
SF512(512
UTRAN and
subframes),
CDMA2000
SF640(640
SRVCC to UTRAN
subframes)
SRVCC to GERAN
PS Inter-RAT
Mobility between E-
UTRAN and
SRVCC
GERAN to GERAN 0ms~0, 40ms~1,
SRVCC
SRVCC to to UTRAN
GERAN 64ms~2, 80ms~3,
PS
PS Inter-RAT
Inter-RAT 100ms~4,
SRVCC
Mobility to GERAN
between
Mobility
PS between E-
Inter-RAT E- 0ms, 40ms, 64ms, 128ms~5,
UTRAN and Interval values 0~30
80ms, 100ms, Not involved
160ms~6, 0.5dB
UTRAN and
Mobility between E-
UTRAN
CDMA2000
SRVCC to GERAN 128ms, 160ms, 256ms~7,
UTRAN
PS and
Inter-RAT 256ms, 320ms, 320ms~8,
PS Inter-RAT
UTRAN Enumeration values ms
Mobility
Mobility between
between E-
E- 480ms, 512ms, 480ms~9,
PS Inter-RAT
UTRAN
SRVCC and
to GERAN 640ms, 1024ms, 512ms~10,
UTRAN
Mobility and
between E-
GERAN
PS Inter-RAT
UTRAN Interval values 1280ms,
-141~-44 2560ms, 640ms~11,
Not involved dBm
UTRAN
PS
Mobility and
Inter-RAT
between E- 5120ms 1024ms~12,
SRVCC
PS to
to UTRAN
Inter-RAT
GERAN
SRVCC GERAN
Mobility
UTRAN
Mobility between
and
between E-
E- 1280ms~13,
PS Inter-RAT
UTRAN and Interval values -40~-6 Not involved
2560ms~14, 0.5dB
UTRAN
Mobility and
between E-
CDMA2000
PS Inter-RAT
GERAN 5120ms~15
UTRAN
Mobility and
between E-
PS Inter-RAT
CDMA2000
UTRAN Interval values -141~-44 Not involved dBm
UTRAN between
Mobility and E-
SRVCC
PS to UTRAN
Inter-RAT
GERAN
UTRAN
Mobility and
between E-
PS Inter-RAT
CDMA2000 Interval values -40~-6 Not involved 0.5dB
UTRAN
Mobility and
between E-
SRVCC
GERAN to UTRAN
UTRAN
3GPP and
R8
PS Inter-RAT
CDMA2000 Interval values 0~11 Not involved None
Specifications
Mobility between E-
SRVCC
PS to UTRAN
Inter-RAT
UTRAN and
Mobility between E-
CDMA2000 Interval values 0~9 Not involved None
UTRAN and
SRVCC
PS to UTRAN
Inter-RAT
CDMA2000 0ms~0, 40ms~1,
Mobility between E- 64ms~2, 80ms~3,
Interval values 0~30 Not involved 0.5dB
UTRAN and 100ms~4,
PS Inter-RAT
CDMA2000
Mobility between E- 0ms, 40ms, 64ms, 128ms~5,
Interval values -63~0 100ms,
80ms, Not involved
160ms~6, 0.5dB
UTRAN and
PS Inter-RAT
CDMA2000 128ms, 160ms, 256ms~7,
Mobility between E- 256ms, 320ms, 320ms~8,
Enumeration values None
UTRAN
PS and
Inter-RAT 480ms, 512ms, 480ms~9,
CDMA2000
Mobility between E- 640ms, 1024ms, 512ms~10,
UTRAN and Interval values 1280ms,
-63~0 2560ms, 640ms~11,
Not involved 0.5dB
CDMA2000
Enhanced 5120ms 1024ms~12,
Load Balancing
Scheduling 1280ms~13,
Interval values 10~254 Not involved
2560ms~14, None
Dynamic
Scheduling 5120ms~15
3GPP R8
Interval values 0~11 Not involved None
Specifications
Coverage Based
Inter-frequency Interval values 0~9 Not involved None
Handover
PS Inter-RAT
Mobility between E-
PS Inter-RAT Interval values 0~9 Not involved None
UTRAN
Mobility and
between E-
PS Inter-RAT
CDMA2000
UTRAN and
Mobility between E-
UTRAN Interval values 0~9 Not involved None
UTRAN and
PS Inter-RAT
CDMA2000
Mobility between E-
Interval values 0~9 Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
PS Inter-RAT Interval values 0~9 Not involved None
UTRAN
Mobility and
between E-
PS Inter-RAT
GERAN
UTRAN and
Mobility between E-
CDMA2000 Interval values 0~9 Not involved None
UTRAN and
UTRAN
Coverage Based
Intra-frequency Interval values 0~9 Not involved None
Handover
DRX Interval values 0~9 Not involved None

3GPP R8
Interval values 0~11 Not involved None
Specifications
QCI1(QCI 1),
QCI2(QCI 2),
QCI3(QCI 3), QCI1~1, QCI2~2,
Enhanced
QCI4(QCI 4), QCI3~3, QCI4~4,
Scheduling
Enumeration values QCI5(QCI 5), QCI5~5, QCI6~6, None
Dynamic
QCI6(QCI 6), QCI7~7, QCI8~8,
Scheduling
Coverage Based QCI7(QCI 7), QCI9~9
Inter-frequency Interval values 0~9
QCI8(QCI 8), Not involved None
Handover
PS Inter-RAT QCI9(QCI 9)
Mobility between E-
PS Inter-RAT Interval values 0~9 Not involved None
UTRAN
Mobility and
between E-
PS Inter-RAT
CDMA2000
UTRAN and
Mobility between E-
UTRAN Interval values 0~9 Not involved None
UTRAN and
PS Inter-RAT
CDMA2000
Mobility between E-
Interval values 0~9 Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
PS Inter-RAT Interval values 0~9 Not involved None
UTRAN
Mobility and
between E-
PS Inter-RAT
GERAN
UTRAN and
Mobility between E-
CDMA2000 Interval values 0~9 Not involved None
UTRAN and
UTRAN
Coverage Based
Intra-frequency Interval values 0~9 Not involved None
Handover
DRX Interval values 0~9 Not involved None
ms5(SRI 5ms),
Basic Scheduling
ms10(SRI 10ms), ms5~0, ms10~1,
Enhanced Enumeration values None
ms20(SRI 20ms), ms20~2, ms40~3
Scheduling
ms40(SRI 40ms)
3GPP R8
Interval values 0~11 Not involved None
Specifications
PS Inter-RAT
Mobility between E-
Interval values 0~9 Not involved None
UTRAN and
PS Inter-RAT
CDMA2000 0ms~0, 40ms~1,
Mobility between E- 64ms~2, 80ms~3,
Interval values 0~30 Not involved 0.5dB
UTRAN and 100ms~4,
PS Inter-RAT
CDMA2000
Mobility between E- 0ms, 40ms, 64ms, 128ms~5,
Interval values -63~0 100ms,
80ms, Not involved
160ms~6, 0.5dB
UTRAN and
PS Inter-RAT
CDMA2000 128ms, 160ms, 256ms~7,
Mobility between E- 256ms, 320ms, 320ms~8,
Enumeration values ms
UTRAN
PS and
Inter-RAT 480ms, 512ms, 480ms~9,
CDMA2000
Mobility between E- 640ms, 1024ms, 512ms~10,
UTRAN and Interval values 1280ms,
-63~0 2560ms, 640ms~11,
Not involved 0.5dB
CDMA2000 5120ms 1024ms~12,
Load
3GPPBalancing
R8 1280ms~13,
Interval values 0~11 Not involved
2560ms~14, None
Specifications
PS Inter-RAT
5120ms~15
Mobility
PS between E-
Inter-RAT
UTRAN between
Mobility and E- Interval values 0~9 Not involved None
GERAN
UTRAN and 0ms~0, 40ms~1,
SRVCC
GERAN to GERAN
Interval values 0~30 64ms~2, 80ms~3,
Not involved 0.5dB
SRVCC to GERAN
PS Inter-RAT 100ms~4,
Service
Mobility
PS based
Inter-RAT inter-
between E- 0ms, 40ms, 64ms, 128ms~5,
RAT handover
Mobility and to E-
UTRAN between Interval values -110~-48
80ms, 100ms, Not involved
160ms~6, dBm
GERAN
GERAN
UTRAN and 128ms, 160ms, 256ms~7,
PS Inter-RAT
SRVCC
GERAN to GERAN 256ms, 320ms, 320ms~8,
Mobility Enumeration values ms
SRVCC between
to GERAN E- 480ms, 512ms, 480ms~9,
UTRAN and inter-
Service based 640ms, 1024ms, 512ms~10,
GERAN
RAT handover to 1280ms,
Interval values -110~-48 2560ms, 640ms~11,
Not involved dBm
Load
GERAN Balancing 5120ms 1024ms~12,
Service based inter- 1280ms~13,
3GPP R8
RAT handover to Interval values 0~11 Not involved
2560ms~14, None
Specifications
GERAN 5120ms~15
PS Inter-RAT
Mobility between E-
UTRAN and Interval values 0~9 Not involved None
PS Inter-RAT
UTRAN
Mobility
SRVCC between
to UTRAN E-
UTRAN and Interval values -48~0 Not involved 0.5dB
PS Inter-RAT
UTRAN
Mobility
PS between
Inter-RAT E- 0ms~0, 40ms~1,
SRVCC to UTRAN
UTRAN and
Mobility between E- Interval values -120~-25 64ms~2, 80ms~3,
Not involved dBm
UTRAN and
UTRAN 100ms~4,
PS Inter-RAT
SRVCC
UTRAN to UTRAN 0ms, 40ms, 64ms, 128ms~5,
Mobility
PS between
Inter-RAT E- Interval values 0~30 100ms,
80ms, Not involved
160ms~6, 0.5dB
SRVCC to UTRAN
UTRAN
Mobility and
between E-
Service based inter- 128ms, 160ms, 256ms~7,
UTRAN
UTRAN and
RAT handover to 256ms, 320ms, 320ms~8,
PS Inter-RAT Enumeration values ms
SRVCC
UTRAN to UTRAN 480ms, 512ms, 480ms~9,
Mobility
Service between
based
Load Balancing E-
inter- 640ms, 1024ms, 512ms~10,
UTRAN
RAT and
handover to
Service based inter- Interval values 1280ms,
-48~0 2560ms, 640ms~11,
Not involved 0.5dB
UTRAN
RAT handover to 5120ms 1024ms~12,
Load
UMTSBalancing 1280ms~13,
Service
Service based
based inter-
inter- Interval values -120~-25 Not involved
2560ms~14, dBm
RAT
RAT handover to
handover to 5120ms~15
UMTS
3GPP
UTRAN R8
Service based inter- Interval values 0~11 Not involved None
Specifications
RAT handover
Coverage to
Based 0ms~0, 40ms~1,
UTRAN
Inter-frequency Interval values 0~9 64ms~2, 80ms~3,
Not involved None
Handover 100ms~4,
Coverage Based 0ms, 40ms, 64ms, 128ms~5,
Inter-frequency Interval values 0~30 100ms,
80ms, Not involved
160ms~6, 0.5dB
Handover 128ms, 160ms, 256ms~7,
Coverage Based
256ms, 320ms, 320ms~8,
Inter-frequency Enumeration values ms
480ms, 512ms, 480ms~9,
Handover
Coverage Based 640ms, 1024ms, 512ms~10,
Inter-frequency Interval values 1280ms,
-141~-44 2560ms, 640ms~11,
Not involved dBm
Handover 5120ms 1024ms~12,
Coverage Based 1280ms~13,
Inter-frequency Interval values -40~-6 Not involved
2560ms~14, 0.5dB
Handover 5120ms~15
Coverage Based
Inter-frequency Interval values -141~-44 Not involved dBm
Handover
Coverage Based
Inter-frequency Interval values -40~-6 Not involved 0.5dB
Handover
Coverage Based
Inter-frequency Interval values 0~30 Not involved 0.5dB
Handover
Coverage Based 0ms~0, 40ms~1,
Inter-frequency Interval values -141~-44 64ms~2, 80ms~3,
Not involved dBm
Handover 100ms~4,
Coverage Based 0ms, 40ms, 64ms, 128ms~5,
Inter-frequency Interval values -40~-6 100ms,
80ms, Not involved
160ms~6, 0.5dB
Handover 128ms, 160ms, 256ms~7,
Coverage Based
256ms, 320ms, 320ms~8,
Inter-frequency Enumeration values ms
480ms, 512ms, 480ms~9,
Handover
640ms, 1024ms, 512ms~10,
Intra-LTE Load 1280ms,
Interval values -141~-44 2560ms, 640ms~11,
Not involved dBm
Balancing 5120ms 1024ms~12,
Intra-LTE Load 1280ms~13,
Interval values -40~-6 Not involved
2560ms~14, 0.5dB
Balancing
5120ms~15
Coverage Based
Inter-frequency Interval values -141~-44 Not involved dBm
Handover
Coverage Based
Inter-frequency Interval values -40~-6 Not involved 0.5dB
Handover
Coverage Based
Inter-frequency Interval values -30~30 Not involved 0.5dB
Handover
Coverage Based
Inter-frequency Interval values -141~-44 Not involved dBm
Handover
Coverage Based
Inter-frequency Interval values -141~-44 Not involved dBm
Handover
3GPP R8
Interval values 0~11 Not involved None
Specifications
Coverage Based
Intra-frequency Interval values 0~9 Not involved None
Coverage
Handover Based
Intra-frequency 0ms~0, 40ms~1,
Handover Interval values 0~30 64ms~2, 80ms~3,
Not involved 0.5dB
Intra-LTE Load 100ms~4,
Coverage
Balancing Based 0ms, 40ms, 64ms, 128ms~5,
Intra-frequency Interval values -30~30
80ms, 100ms, Not involved
160ms~6, 0.5dB
Handover 128ms, 160ms, 256ms~7,
Coverage Based
256ms, 320ms, 320ms~8,
Intra-frequency Enumeration values ms
480ms, 512ms, 480ms~9,
Handover
RAN Sharing with 640ms, 1024ms, 512ms~10,
Common Carrier 1280ms, 2560ms, 640ms~11,
Interval values 0~3 Not involved None
RAN Sharing with 5120ms 1024ms~12,
Dedicated Carrier 1280ms~13,
None Character string 0~31 characters
CNOPERATOR_PR Not involved
2560ms~14, None
RAN Sharing with IMARY(Primary 5120ms~15
CNOPERATOR_PR
Common Carrier Operator), IMARY~0,
Enumeration values None
RAN Sharing with CNOPERATOR_SE CNOPERATOR_SE
Dedicated Carrier CONDARY(Second CONDARY~1
None Character string ary Operator)
3 characters Not involved None

None Character string 2~3 characters Not involved None


RAN Sharing with
Common Carrier
Interval values 0~65535 Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Interval values 0~3 Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Interval values 0~65535 Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Interval values 0~3 Not involved None
RAN Sharing with
Dedicated Carrier
Emergency Call Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None

Emergency Call Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None

Emergency Call Interval values 1~15 Not involved None


INDEPENDENT(Ind
ependent Operator
Emergency Call Interval values 1~15
Mode), Not involved None
RAN Sharing with SHARED_FREQ(S INDEPENDENT~0,
Common Carrier hared Frequency SHARED_FREQ~1,
Enumeration values None
RAN Sharing with Sharing Mode), SEPARATED_FRE
RAN Sharing
Dedicated with
Carrier SEPARATED_FRE Q~2
Common Carrier Q(Separate
Interval values 0~3 Not involved None
RAN Sharing with Frequency Sharing
Dedicated Carrier Mode)
RAN Sharing with
Common Carrier
RAN Sharing with
Interval values 1~100 Not involved %
Dedicated Carrier
License
Management
None Interval values 1~300 Not involved s
S1-flex
RAN Sharing with
Common Carrier Interval values 1~300 Not involved s
RAN Sharing with
Dedicated Carrier
S1-flex Interval values 0~15 Not involved None

None Interval values 0~47 Not involved None


S1-flex
RAN Sharing with
Common Carrier Interval values 0~3 Not involved None
RAN
3GPPSharing
R8 with Release_R8(Releas
Dedicated Carrier
Specifications e_R8), Release_R8~0,
Enumeration values None
3GPP R9 Release_R9(Releas Release_R9~1
Specifications e_R9)
FALSE(FALSE),
None Enumeration values FALSE~0, TRUE~1 None
TRUE(TRUE)
Normal(Normal),
Normal~0,
None Enumeration values Abnormal(Abnormal None
Abnormal~1
)
Normal(Normal),
Normal~0,
None Enumeration values Abnormal(Abnormal None
Abnormal~1
)
FALSE(FALSE),
FALSE~0, TRUE~1,
S1-flex Enumeration values TRUE(TRUE), None
NULL~2
NULL(NULL)
None Interval values 0~3600 Not involved None

None Interval values 0~100 Not involved None

None Character string 0~150 characters Not involved None


S1-flex
RAN Sharing with
Common Carrier Character string 0~224 characters Not involved None
RAN Sharing with
Dedicated Carrier
None Character string 0~300 characters Not involved None

Mobility
None
Management Interval values 0~255 Not involved None
Coverage Based
Intra-frequency
Interval values 16~47 Not involved None
Handover
Coverage Based
Inter-frequency
None Interval values 0~47 Not involved None
Handover
RAN Sharing with
Common Carrier
Interval values 0~3 Not involved None
RAN Sharing with
3GPP R8 Carrier
Dedicated Release_R8(Releas
Specifications e_R8), Release_R8~0,
Enumeration values FORBID_AUTO_R None
3GPP R9 Release_R9(Releas Release_R9~1
Specifications MV(Forbid
e_R9) Auto FORBID_AUTO_R
Remove), MV~0,
None Enumeration values None
PERMIT_AUTO_R PERMIT_AUTO_R
MV(Permit Auto MV~1
None Character string Remove)
0~50 characters Not involved None
SF10(10
subframes),
SF20(20
PSF1(1 subframe),
subframes),
PSF2(2
SF32(32subframes),
None Character string 0~50
PSF3(3 characters
subframes),
subframes), Not involved None
PSF4(4
SF40(40subframes),
PSF1(1 subframe),
Normal(Normal),
PSF5(5 subframes),
subframes),
PSF2(2 subframes), Normal~0,
None Enumeration values Abnormal(Abnormal
PSF6(6 subframes), None
SF64(64
PSF3(3 Abnormal~1
)PSF8(8 subframes),
subframes),
subframes),
PSF4(4 subframes),
PSF10(10 SF10~0, SF20~1,
DRX Enumeration values SF80(80
OFF(Off), ON(On) OFF~0,
PSF5(5 subframes),
subframes), SF32~2,ON~1
SF40~3, None
PSF6(6 subframes), SF64~4, SF80~5,
PSF20(20
SF128(128
PSF8(8subframes),
SF2(2 subframes), PSF1~0,
SF128~6,
PSF1~0, PSF2~1,
PSF2~1,
DRX Enumeration values OFF(Off),
subframes),
PSF10(10
SF5(5 ON(On)
subframes), OFF~0, ON~1 None
PSF3~2,
SF160~7,PSF4~3,
PSF3~2, PSF4~3,
PSF30(30
SF160(160
subframes),
SF8(8 subframes), PSF5~4,
PSF5~4, PSF6~5,
SF256~8, PSF6~5,
subframes),
PSF20(20
SF10(10
DRX Enumeration values PSF8~6,
PSF8~6, PSF10~7,
SF320~9, PSF10~7, subframe
PSF40(40
SF256(256
subframes), PSF20~8,
SF512~10,
PSF20~8,
subframes),
PSF30(30
SF16(16 PSF30~9,
SF640~11,
PSF30~9,
DRX Enumeration values PSF50(50
SF320(320
subframes), subframe
PSF40~10,
SF1024~12,
PSF40~10,
subframes),
PSF40(40
SF20(20 PSF50~11,
SF1280~13,
PSF50~11,
PSF60(60
SF512(512
subframes), PSF60~12,
SF2048~14,
PSF60~12,
DRX Enumeration values subframes),
PSF50(50
SF32(32 SF2~0, SF5~1, subframe
PSF80~13,
SF2560~15
PSF80~13,
PSF80(80
SF640(640
UU_DISABLE(Disa
subframes), SF8~2, SF10~3,
PSF100~14,
PSF100~14,
subframes),
ble),
PSF60(60
SF40(40 UU_DISABLE~0,
SF16~4, SF20~5,
DRX Enumeration values PSF200~15,
PSF200~15 None
PSF100(100
SF1024(1024
UU_ENABLE(Enabl
subframes), UU_ENABLE~1
SF32~6, SF40~7,
PSF300~16,
subframes),
e)
PSF80(80
SF64(64 SF64~8, SF80~9,
PSF500~17,
DRX Enumeration values PSF200(200
SF1280(1280
subframes), SF128~10, subframe
PSF750~18,
subframes),
PSF100(100
SF80(80 SF160~11,
PSF1280~19,
PSF300(300
SF2048(2048
subframes), SF256~12,
PSF1920~20,
DRX Interval values subframes),
1~16
PSF200(200
SF128(128 Not involved
SF320~13, None
PSF2560~21
Enhanced PSF500(500
SF2560(2560
subframes)
subframes), SF512~14,
Scheduling subframes),
subframes)
SF160(160
IMSSignalling(IMS SF640~15
Interval values 10~254
MinGbrRate_0_KB(
PSF750(750 Not involved
MinGbrRate_0_KB None
Dynamic subframes),
Signalling),
Enhanced
Scheduling 0KB/s),
subframes), IMSSignalling~5,
~0,
SF256(256
LowDelay(Low
Scheduling MinGbrRate_1_KB(
PSF1280(1280 LowDelay~7,
MinGbrRate_1_KB
Enumeration values subframes),
Delay),
MinGbrRate_0_KB( MinGbrRate_0_KB None
Dynamic 1KB/s),
subframes), TCPorBuffStreamin
~8000,
Enhanced SF320(320
TCPorBuffStreamin
0KB/s), ~0,
Scheduling
PS Inter-RAT MinGbrRate_2_KB(
PSF1920(1920 g~9
MinGbrRate_2_KB
Scheduling subframes),
g(TCP Based or
MinGbrRate_1_KB( MinGbrRate_1_KB
Mobility between E- Interval values 2KB/s),
subframes),
1~1000
SF512(512 ~16000,
Not involved 0.001
Dynamic Buffered
1KB/s), Streaming) ~8000,
UTRAN
Enhanced and MinGbrRate_4KB(4
PSF2560(2560
subframes), MinGbrRate_4KB~
Scheduling
UTRAN MinGbrRate_2_KB(
KB/s),
subframes) MinGbrRate_2_KB
32000,
Scheduling SF640(640
2KB/s), ~16000,
PS Inter-RAT Interval values 1~1000
MinGbrRate_8_KB( Not involved
MinGbrRate_8_KB 0.001
Dynamic subframes)
MinGbrRate_4KB(4 MinGbrRate_4KB~
Mobility between E-
Scheduling 8KB/s), ~64000,
Basic Scheduling KB/s), 32000,
UTRAN and MinGbrRate_16_K MinGbrRate_16_K
Enhanced Enumeration values MinGbrRate_8_KB( MinGbrRate_8_KB KB/s
GERAN B(16KB/s), B~128000,
Scheduling 8KB/s), ~64000,
PS Inter-RAT
Basic Scheduling MinGbrRate_32_K MinGbrRate_32_K
Mobility between E- MinGbrRate_16_K
B(32KB/s), MinGbrRate_16_K
B~256000,
Enhanced Enumeration values KB/s
UTRAN and B(16KB/s),
PBR_0_KBps(0KB/
MinGbrRate_64_K B~128000,
MinGbrRate_64_K
Scheduling
Basic Scheduling
CDMA2000 MinGbrRate_32_K
s),
B(64KB/s), MinGbrRate_32_K
B~512000,
Enhanced
SRVCC to UTRAN Interval values B(32KB/s),
PBR_8_KBps(8KB/
0~10
MinGbrRate_128_K B~256000,
Not involved
MinGbrRate_128_K 0.1
Scheduling
SRVCC to GERAN MinGbrRate_64_K
s),
B(128KB/s), MinGbrRate_64_K
B~1024000,
PS Inter-RAT B(64KB/s),
PBR_16_KBps(16K B~512000,
PBR_0_KBps~0,
Inter-RAT Load E-
Mobility between MinGbrRate_256_K MinGbrRate_256_K
Interval values 0~39
MinGbrRate_128_K
B/s), Not involved
MinGbrRate_128_K
PBR_8_KBps~1, None
Sharing
UTRAN andto UTRAN B(256KB/s), B~2048000,
Inter-RAT Load B(128KB/s),
PBR_32_KBps(32K
MinGbrRate_512_K B~1024000,
PBR_16_KBps~2,
MinGbrRate_512_K
Basic
UTRAN Scheduling
Sharing to GERAN MinGbrRate_256_K
B/s),
B(512KB/s) MinGbrRate_256_K
PBR_32_KBps~3,
B~4096000
Enhanced
PS Inter-RAT Enumeration values KB/s
Service B(256KB/s),
PBR_64_KBps(64K B~2048000,
PBR_64_KBps~4,
Mobility based
Scheduling
betweeninter-
E- MinGbrRate_512_K
B/s), MinGbrRate_512_K
PBR_128_KBps~5,
Basic
RAT Scheduling
UTRAN and to
handover
B(512KB/s)
PBR_128_KBps(12 B~4096000
PBR_256_KBps~6,
Enhanced
UTRAN Interval values 9~16 Not involved None
GERAN 8KB/s), PBR_INFINITY~7
Scheduling
Service
Logical based inter-
Channel
PS Inter-RAT PBR_256_KBps(25
RAT handover
Management
Mobility betweento E-
Interval values 0~39
6KB/s), Not involved None
GERAN
Radio
UTRAN Bearer
and
CS Fallback
Management to PBR_INFINITY(Infi
PAID_USER(Paid
Basic Scheduling
CDMA2000
UTRAN nity)
User), PAID_USER~0,
Enhanced
SRVCC to UTRAN Enumeration values None
CS Fallback to FREE_USER(Free FREE_USER~1
Scheduling
SRVCC to GERAN
GERAN User)
Inter-RAT Load
CS Fallback to Interval values 0~39 Not involved None
Sharing to UTRAN
CDMA2000 1xRTT
Inter-RAT Load
Sharing to GERAN
Service based inter-
RAT handover to
UTRAN
Service based inter-
RAT handover to
s),
Tpollretrans_m15(1
Tstatprohibit_m0(0 Tpollretrans_m10~1
,
Tpollretrans_m10(1
5ms),
ms), ,Tstatprohibit_m0~0,
Tpollretrans_m20~3
0ms),
Tpollretrans_m20(2
Tstatprohibit_m5(5 Tpollretrans_m15~2
Tstatprohibit_m5~1,
,
Tpollretrans_m15(1
0ms),
Tstatprohibit_m0(0
ms), ,Tpollretrans_m25~4
Tstatprohibit_m10~
5ms),
Tpollretrans_m25(2
ms), Tstatprohibit_m0~0,
Tstatprohibit_m10(1 Tpollretrans_m20~3
2,
,
Tpollretrans_m20(2
5ms),
Tstatprohibit_m5(5 Tstatprohibit_m5~1,
0ms), ,Tstatprohibit_m15~
Tpollretrans_m30~5
SRVCC to UTRAN 0ms),
Tpollretrans_m30(3
ms), Tstatprohibit_m10~
PS Inter-RAT Tstatprohibit_m15(1 Tpollretrans_m25~4
3,
,
Tpollretrans_m25(2
0ms),
Tstatprohibit_m10(1 2,
Mobility between E- 5ms), ,PS_HO~0,
Tstatprohibit_m20~
Tpollretrans_m35~6
Bit field type PS_HO,
5ms), SRVCC
Tpollretrans_m35(3
0ms), Tstatprohibit_m15~ None
UTRAN and Tstatprohibit_m20(2 SRVCC~1
Tpollretrans_m30~5
4,
,
Tpollretrans_m30(3
5ms),
Tstatprohibit_m15(1 3,
UTRAN 0ms), ,Tstatprohibit_m25~
Tpollretrans_m40~7
0ms),
Tpollretrans_m40(4
5ms), Tstatprohibit_m20~
SRVCC
PS to GERAN
Inter-RAT Bit field type SRVCC
Tstatprohibit_m25(2 Tpollretrans_m35~6
,SRVCC~0
5, None
Tpollretrans_m35(3
0ms),
Tstatprohibit_m20(2 4,
PS Inter-RAT
Mobility between E- 5ms), ,Tstatprohibit_m30~
Tpollretrans_m45~8
5ms),
PS_HO,
Tpollretrans_m45(4
0ms), PS_HO~0,
Tstatprohibit_m25~
Mobility between
UTRAN and E- Tstatprohibit_m30(3 Tpollretrans_m40~7
6,
,
Bit field type Tpollretrans_m40(4
NACC_HO,
5ms),
Tstatprohibit_m25(2 NACC_HO~1,
5, None
UTRAN and
GERAN 0ms), ,Tpollretrans_m50~9
Tstatprohibit_m35~
0ms),
NON_NACC_HO
Tpollretrans_m50(5
5ms), NON_NACC_HO~2
Tstatprohibit_m30~
PS Inter-RAT
GERAN
PS Inter-RAT Tstatprohibit_m35(3 Tpollretrans_m45~8
7,
,
Tpollretrans_m45(4
0ms),
Tstatprohibit_m30(3 6,
Mobility
Mobility between
between E-
E- SRVCC(CDMA1XR
5ms), ,Tstatprohibit_m40~
Tpollretrans_m55~1
Bit field type 5ms),
Tpollretrans_m55(5
0ms), SRVCC~0
Tstatprohibit_m35~ None
UTRAN
UTRAN and
and TTHoSwitch)
Tstatprohibit_m40(4 Tpollretrans_m50~9
8,
0,
PS Inter-RAT Tpollretrans_m50(5
5ms),
Tstatprohibit_m35(3 7,
CDMA2000
CDMA2000 0ms), ,Tpollretrans_m60~1
Tstatprohibit_m45~
Mobility between E- 0ms),
OPT_HO,
Tpollretrans_m60(6
5ms), OPT_HO~0,
Tstatprohibit_m40~
SRVCC to UTRAN Bit field type Tstatprohibit_m45(4 Tpollretrans_m55~1
9,
1, None
UTRAN and Tpollretrans_m55(5
NON_OPT_HO
0ms),
Tstatprohibit_m40(4 NON_OPT_HO~1
8,
SRVCC to GERAN 5ms),
PERMIT_HO_ENU 0,
Tstatprohibit_m50~
Tpollretrans_m65~1
PERMIT_HO_ENU
CDMA2000 5ms),
Tpollretrans_m65(6
0ms), Tstatprohibit_m45~
Inter-RAT Load Tstatprohibit_m50(5
M(Permit Ho), Tpollretrans_m60~1
10,
2,
M~0,
Enumeration values Tpollretrans_m60(6
5ms),
Tstatprohibit_m45(4 9, None
Sharing to UTRAN 0ms),
FORBID_HO_ENU
DiscardTimer_50(5 1,
Tstatprohibit_m55~1
Tpollretrans_m70~1
FORBID_HO_ENU
DiscardTimer_50~0
0ms),
Tpollretrans_m70(7
5ms), PERMIT_FAST_AN
Tstatprohibit_m50~
Inter-RAT Load PERMIT_FAST_AN
Tstatprohibit_m55(5
M(Forbid
0 ms), Ho) Tpollretrans_m65~1
1,
3,
M~1
,R_MEAS_ENUM~0
Automatic Neighbor Tpollretrans_m65(6
0ms),
Tstatprohibit_m50(5 10,
Sharing to GERAN R_MEAS_ENUM,
5ms),
DiscardTimer_100( 2,
Tstatprohibit_m60~
Tpollretrans_m75~1
DiscardTimer_100~
Relation (ANR) Enumeration values 5ms),
Tpollretrans_m75(7
0ms), ,Tstatprohibit_m55~1 None
Service based FORBID_FAST_AN
Tstatprohibit_m60(6 Tpollretrans_m70~1
12,
4,
Inter-RAT
Logical ANR inter-
Channel 100
5ms),ms),
Tpollretrans_m70(7
Tstatprohibit_m55(5
1,
FORBID_FAST_AN
1,
RAT handover to R_MEAS_ENUM
PollByte_kb25(25
0ms),
DiscardTimer_150( 3,
Tstatprohibit_m65~
Tpollretrans_m80~1
DiscardTimer_150~
Management 0ms),
Tpollretrans_m80(8
5ms), R_MEAS_ENUM~1
Tstatprohibit_m60~
UTRAN Interval values kBytes),
Tstatprohibit_m65(6
0~39ms),
150 Tpollretrans_m75~1
13,
Not involved
5,
2, None
Radio Bearer Tpollretrans_m75(7
Maxretx_Threshold
0ms),
Tstatprohibit_m60(6 Maxretx_Threshold
12,
Service
Logical based inter-
Channel PollByte_kb50(50
5ms),
DiscardTimer_300( 4,
Tstatprohibit_m70~
Tpollretrans_m85~1
DiscardTimer_300~
Management 5ms),
_t1(1),
PollByte_kb25(25
Tpollretrans_m85(8
0ms), _t1~0,
Tstatprohibit_m65~
RAT handover to
Management kBytes),
Tstatprohibit_m70(7
300 ms), Tpollretrans_m80~1
14,
6,
3,
Enumeration values Tpollretrans_m80(8
Maxretx_Threshold
kBytes),
5ms),
Tstatprohibit_m65(6 Maxretx_Threshold
13, ms
GERAN
Radio Bearer PollByte_kb75(75
0ms),
DiscardTimer_500(
Maxretx_Threshold 5,
Tstatprohibit_m75~
Tpollretrans_m90~1
DiscardTimer_500~
Maxretx_Threshold
0ms),
RlcMode_AM(Ackn
_t2(2),
PollByte_kb50(50
Tpollretrans_m90(9
5ms), _t2~1,
Tstatprohibit_m70~
Logical Channel
CS Fallback
Management to kBytes),
Tstatprohibit_m75(7
500 ms), Mode),
_t1(1), Tpollretrans_m85~1
15,
7,
4,
_t1~0,
Tpollretrans_m85(8
Treordering_m0(0m
owledge
Maxretx_Threshold
kBytes),
0ms),
Tstatprohibit_m70(7 PollByte_kb25~0,
Maxretx_Threshold
14,
Management
UTRAN PollByte_kb100(10
5ms),
DiscardTimer_750(
Maxretx_Threshold 6,
RlcMode_AM~1,
Tstatprohibit_m80~
Tpollretrans_m95~1
DiscardTimer_750~
Maxretx_Threshold
Enumeration values 5ms),
s),
RlcMode_UM(Un-
_t3(3),
PollByte_kb75(75
Tpollretrans_m95(9
0ms), Treordering_m0~0,
PollByte_kb50~1,
_t3~2,
Tstatprohibit_m75~ None
Radio
CS Bearerto
Fallback 0 kBytes),
Tstatprohibit_m80(8
750 ms),
_t2(2), Tpollretrans_m90~1
RlcMode_UM~2
16,
8,
5,
_t2~1,
Logical Channel Tpollretrans_m90(9
Treordering_m5(5m
acknowledge
Maxretx_Threshold
kBytes),
5ms),
Tstatprohibit_m75(7 Treordering_m5~1,
PollByte_kb75~2,
Maxretx_Threshold
15,
Management
GERAN PollByte_kb125(12
0ms),
Treordering_m0(0m
DiscardTimer_1500
Maxretx_Threshold 7,
Tstatprohibit_m85~
PollByte_kb25~0,
Tpollretrans_m100~
DiscardTimer_1500
Maxretx_Threshold
Management 0ms),
s),
Mode)
_t4(4),
PollByte_kb100(10
Tpollretrans_m100(
5ms), Treordering_m10~2
PollByte_kb100~3,
_t4~3,
Tstatprohibit_m80~
CS Fallback Enumeration values 5 kBytes),
Tstatprohibit_m85(8
s), Tpollretrans_m95~1
17,
Treordering_m0~0,
PollByte_kb50~1,
19, None
Radio Bearerto (1500
_t3(3), ms),
Tpollretrans_m95(9
Treordering_m10(1
Maxretx_Threshold
0 kBytes),
100ms),
Tstatprohibit_m80(8
PollByte_kb250(25
5ms),
~6,
_t3~2,
,PollByte_kb125~4,
Maxretx_Threshold
16,
8,
Tstatprohibit_m90~
CDMA2000
Logical 1xRTT
Channel Treordering_m5(5m
DiscardTimer_Infinit
Maxretx_Threshold
5ms),
0ms), Treordering_m5~1,
PollByte_kb75~2,
Tpollretrans_m105~
DiscardTimer_Infinit
Maxretx_Threshold
Treordering_m15~3
PollByte_kb250~5,
Management _t6(6),
PollByte_kb125(12
Tpollretrans_m105(
0ms),
0 kBytes),
Tstatprohibit_m90(9 _t6~4,
Tstatprohibit_m85~
Tpollretrans_m100~
18,
Management s),
y(infinity)
_t4(4),
Tpollretrans_m100(
Treordering_m15(1 Treordering_m10~2
PollByte_kb100~3,
20,
y~7
_t4~3,
,17,
PollByte_kb375~6,
Enumeration values Maxretx_Threshold
5 kBytes),
105ms),
Tstatprohibit_m85(8
PollByte_kb375(37
0ms), Maxretx_Threshold
19,
Tstatprohibit_m95~ None
Radio Bearer Treordering_m10(1
Maxretx_Threshold
PollPdu_p4(4
100ms),
5ms), ,Treordering_m20~4
PollByte_kb125~4,
Tpollretrans_m110~
Maxretx_Threshold
PollByte_kb500~7,
Logical Channel _t8(8),
PollByte_kb250(25
Tpollretrans_m110(
5ms),
5 kBytes),
Tstatprohibit_m95(9 _t8~5,
Tstatprohibit_m90~
Tpollretrans_m105~
19,
Management 0ms),
_t6(6),
PDUs),
Tpollretrans_m105(
Treordering_m20(2 Treordering_m15~3
PollByte_kb250~5,
21,
_t6~4,
,PollByte_kb750~8,
Management Maxretx_Threshold
0 kBytes),
110ms),
Tstatprohibit_m90(9
PollByte_kb500(50
5ms), Maxretx_Threshold
18,
20,
Enumeration values Treordering_m15(1
Maxretx_Threshold
PollPdu_p8(8
105ms),
0ms), ,Tstatprohibit_m100
PollByte_kb375~6,
Tpollretrans_m115~
Maxretx_Threshold
Treordering_m25~5
PollByte_kb1000~9, byte
Radio Bearer _t16(16),
PollByte_kb375(37
Tpollretrans_m115(
0ms),
0 kBytes),
PollPdu_p4(4
Tstatprohibit_m100( _t16~6,
Tstatprohibit_m95~
Tpollretrans_m110~
~20,
5ms),
_t8(8),
PDUs),
Tpollretrans_m110(
Treordering_m25(2 Treordering_m20~4
PollByte_kb500~7,
22,
_t8~5,
,PollByte_kb1250~1
Logical Channel
Management Maxretx_Threshold
5 kBytes),
115ms),
Tstatprohibit_m95(9
PollByte_kb750(75
PDUs),
100ms), Maxretx_Threshold
19,
21,
Treordering_m20(2
Maxretx_Threshold
PollPdu_p16(16
110ms),
5ms), ,Tstatprohibit_m105
PollByte_kb750~8,
Tpollretrans_m120~
Maxretx_Threshold
PollPdu_p4~0,
Treordering_m30~6
0,
Management _t32(32)
PollByte_kb500(50
Tpollretrans_m120(
5ms),
0 kBytes),
PollPdu_p8(8
Tstatprohibit_m105( _t32~7
Tstatprohibit_m100
Tpollretrans_m115~
~21,
Enumeration values 0ms),
_t16(16),
PDUs),
Tpollretrans_m115(
Treordering_m30(3 Treordering_m25~5
PollByte_kb1000~9,
,23,
_t16~6,
PollPdu_p8~1,
PollByte_kb1500~1 byte
Radio Bearer 0 kBytes),
120ms),
Tstatprohibit_m100(
PollByte_kb1000(1
PDUs),
105ms),
Treordering_m25(2 ~20,
22,
,Tstatprohibit_m110~
Logical Channel Maxretx_Threshold
PollPdu_p32(32
115ms),
0ms), PollByte_kb1250~1
Tpollretrans_m125~
Maxretx_Threshold
PollPdu_p16~2,
Treordering_m35~7
1,
Management PollByte_kb750(75
Tpollretrans_m125(
100ms),
000 kBytes),
PollPdu_p16(16
Tstatprohibit_m110(
5ms), Tstatprohibit_m105
Tpollretrans_m120~
PollPdu_p4~0,
22,
Treordering_m30~6
Management _t32(32)
PDUs),
Tpollretrans_m120(
Treordering_m35(3 0,
24,
_t32~7
,PollPdu_p32~3,
PollByte_kb2000~1
Enumeration values 0 kBytes),
125ms),
Tstatprohibit_m105(
PollByte_kb1250(1
PDUs),
110ms),
Treordering_m30(3 ~21,
23,
PollPdu_p8~1,
,Tstatprohibit_m115~ None
Radio Bearer PollPdu_p64(64
120ms),
5ms), PollByte_kb1500~1
Tpollretrans_m130~
PollPdu_p64~4,
Treordering_m40~8
2,
Logical Channel PollByte_kb1000(1
Tpollretrans_m130(
105ms),
250 kBytes),
PollPdu_p32(32
Tstatprohibit_m115(
0ms), Tstatprohibit_m110~
Tpollretrans_m125~
PollPdu_p16~2,
23,
Treordering_m35~7
Management PDUs),
Tpollretrans_m125(
Treordering_m40(4 1,
25,
PollPdu_p128~5,
,22,
PollByte_kb3000~1
Management 000 kBytes),
130ms),
Tstatprohibit_m110(
PollByte_kb1500(1
PDUs),
115ms),
Treordering_m35(3 24,
PollPdu_p32~3,
,Tstatprohibit_m120
Enumeration values PollPdu_p128(128
125ms),
0ms), PollByte_kb2000~1
Tpollretrans_m135~
PollPdu_p256~6,
Treordering_m45~9
3, None
Radio Bearer PollByte_kb1250(1
Tpollretrans_m135(
110ms),
500 kBytes),
PollPdu_p64(64
Tstatprohibit_m120(
5ms), Tstatprohibit_m115~
Tpollretrans_m130~
PollPdu_p64~4,
~24,
Treordering_m40~8
PDUs),
Tpollretrans_m130(
Treordering_m45(4 2,
,26,
PollPdu_Infinity~7
PollByte_infinity~14
Logical Channel
Management 250 kBytes),
135ms),
Tstatprohibit_m115(
PollByte_kb2000(2
PDUs),
120ms),
Treordering_m40(4 23,
25,
PollPdu_p128~5,
,Tstatprohibit_m125
PollPdu_p256(256
130ms),
5ms), PollByte_kb3000~1
Tpollretrans_m140~
Treordering_m50~1
Management PollByte_kb1500(1
Tpollretrans_m140(
115ms),
000 kBytes),
PollPdu_p128(128
Tstatprohibit_m125(
0ms), Tstatprohibit_m120
Tpollretrans_m135~
PollPdu_p256~6,
~25,
Treordering_m45~9
Enumeration values PDUs),
Tpollretrans_m135(
Treordering_m50(5 3,
27,
0, ms
Radio Bearer 500 kBytes),
140ms),
Tstatprohibit_m120(
PollByte_kb3000(3
PDUs),
125ms),
Treordering_m45(4 ~24,
26,
PollPdu_Infinity~7
Tstatprohibit_m130
,Tpollretrans_m145~
Logical Channel PollPdu_Infinity(infi
135ms),
0ms), PollByte_infinity~14
Treordering_m55~1
Management PollByte_kb2000(2
Tpollretrans_m145(
120ms),
000 kBytes),
PollPdu_p256(256
Tstatprohibit_m130(
5ms), Tstatprohibit_m125
Tpollretrans_m140~
~26,
Treordering_m50~1
Management nite PDUs)
Tpollretrans_m140(
Treordering_m55(5 28,
1,
Enumeration values 000 kBytes),
145ms),
Tstatprohibit_m125(
PollByte_infinity(infi
PDUs),
130ms),
Treordering_m50(5 ~25,
27,
Tstatprohibit_m135
0, ms
Radio Bearer 140ms),
5ms), Tpollretrans_m150~
Treordering_m60~1
Logical Channel PollByte_kb3000(3
Tpollretrans_m150(
125ms),
nite kBytes)
PollPdu_Infinity(infi
Tstatprohibit_m135(
0ms), Tstatprohibit_m130
Tpollretrans_m145~
~27,
Treordering_m55~1
Management Tpollretrans_m145(
Treordering_m60(6 29,
2,
Management 000
nite kBytes),
150ms),
Tstatprohibit_m130(
PDUs)
135ms),
Treordering_m55(5 ~26,
28,
Tstatprohibit_m140
1,
Enumeration values 145ms),
0ms), Tpollretrans_m155~
Treordering_m65~1 ms
Radio Bearer PollByte_infinity(infi
Tpollretrans_m155(
130ms),
Tstatprohibit_m140(
5ms), Tstatprohibit_m135
Tpollretrans_m150~
~28,
Treordering_m60~1
Tpollretrans_m150(
Treordering_m65(6 30,
3,
Logical Channel
Management nite kBytes)
155ms),
Tstatprohibit_m135(
140ms),
Treordering_m60(6 ~27,
29,
Tstatprohibit_m145
2,
150ms),
5ms), Tpollretrans_m160~
Treordering_m70~1
Management Tpollretrans_m160(
135ms),
Tstatprohibit_m145(
0ms), Tstatprohibit_m140
Tpollretrans_m155~
~29,
Treordering_m65~1
Enumeration values Tpollretrans_m155(
Treordering_m70(7 31,
4, ms
Radio Bearer 160ms),
Tstatprohibit_m140(
145ms),
Treordering_m65(6 ~28,
30,
Tstatprohibit_m150
3,
Logical Channel 155ms),
0ms), Tpollretrans_m165~
Treordering_m75~1
Management Tpollretrans_m165(
140ms),
Tstatprohibit_m150(
5ms), Tstatprohibit_m145
Tpollretrans_m160~
~30,
Treordering_m70~1
Management Tpollretrans_m160(
Treordering_m75(7 32,
5,
Enumeration values 165ms),
Tstatprohibit_m145(
150ms),
Treordering_m70(7 ~29,
31,
Tstatprohibit_m155
4, ms
Radio Bearer 160ms),
5ms), Tpollretrans_m170~
Treordering_m80~1
Logical Channel Tpollretrans_m170(
145ms),
Tstatprohibit_m155(
0ms), Tstatprohibit_m150
Tpollretrans_m165~
~31,
Treordering_m75~1
Management Tpollretrans_m165(
Treordering_m80(8 33,
6,
Management 170ms),
Tstatprohibit_m150(
155ms),
Treordering_m75(7 ~30,
32,
Tstatprohibit_m160
5,
Enumeration values 165ms),
0ms), Tpollretrans_m175~
Treordering_m85~1 ms
Radio Bearer Tpollretrans_m175(
150ms),
Tstatprohibit_m160(
5ms), Tstatprohibit_m155
Tpollretrans_m170~
~32,
Treordering_m80~1
Tpollretrans_m170(
Treordering_m85(8 34,
7,
Logical Channel
Management 175ms),
Tstatprohibit_m155(
PdcpSnsize_7bits(7
160ms),
Treordering_m80(8 ~31,
PdcpSnsize_7bits~
33,
Tstatprohibit_m165
6,
170ms),
5ms), Tpollretrans_m180~
Treordering_m90~1
Management Tpollretrans_m180(
155ms),
bits per second),
Tstatprohibit_m165(
0ms), Tstatprohibit_m160
0,
Tpollretrans_m175~
~33,
Treordering_m85~1
Enumeration values Tpollretrans_m175(
Treordering_m90(9 35,
8, bit
Radio Bearer 180ms),
Tstatprohibit_m160(
PdcpSnsize_12bits(
160ms),
Treordering_m85(8 ~32,
PdcpSnsize_12bits
34,
Tstatprohibit_m170
7,
175ms),
0ms), Tpollretrans_m185~
Treordering_m95~1
Management Tpollretrans_m185(
160ms),
12 bits per second)
Tstatprohibit_m170(
5ms), Tstatprohibit_m165
~1
Tpollretrans_m180~
~34,
Treordering_m90~1
Tpollretrans_m180(
Treordering_m95(9 36,
9,
185ms),
Tstatprohibit_m165(
170ms),
Treordering_m90(9 ~33,
35,
Tstatprohibit_m175
8,
180ms),
5ms), Tpollretrans_m190~
Treordering_m100~
Tpollretrans_m190(
160ms),
Tstatprohibit_m175(
0ms), Tstatprohibit_m170
Tpollretrans_m185~
~35,
Treordering_m95~1
Tpollretrans_m185(
Treordering_m100( 37,
20,
190ms),
Tstatprohibit_m170(
175ms),
Treordering_m95(9 ~34,
36,
Tstatprohibit_m180
9,
185ms),
100ms), Tpollretrans_m195~
Treordering_m110~
Tpollretrans_m195(
170ms),
Tstatprohibit_m180(
5ms), Tstatprohibit_m175
Tpollretrans_m190~
~36,
Treordering_m100~
Tpollretrans_m190(
Treordering_m110(1 38,
21,
195ms),
Tstatprohibit_m175(
180ms),
Treordering_m100( ~35,
37,
Tstatprohibit_m185
20,
190ms),
10ms), Tpollretrans_m200~
Treordering_m120~
Tpollretrans_m200(
175ms),
Tstatprohibit_m185(
100ms), Tstatprohibit_m180
Tpollretrans_m195~
~37,
Treordering_m110~
Tpollretrans_m195(
Treordering_m120( 39,
22,
5ms),
Treordering_m45(4 Treordering_m40~8
,
Treordering_m40(4
5ms), ,Treordering_m50~1
0ms),
Treordering_m50(5 Treordering_m45~9
0,
Treordering_m45(4
0ms), ,Treordering_m55~1
5ms),
Treordering_m55(5 Treordering_m50~1
1,
Treordering_m50(5
5ms), 0,
Treordering_m60~1
Logical Channel RlcSnSize_size5(5b
0ms),
Treordering_m60(6 Treordering_m55~1
2,
RlcSnSize_size5~0,
Management its),
Treordering_m55(5
0ms), 1,
Treordering_m65~1
Enumeration values RlcSnSize_size10~ bit
Radio Bearer RlcSnSize_size10(1
5ms),
Treordering_m65(6 Treordering_m60~1
3,
Logical Channel RlcSnSize_size5(5b 1
Management 0bits)
Treordering_m60(6
5ms), 2,
RlcSnSize_size5~0,
Treordering_m70~1
Management its),
0ms), Treordering_m65~1
Enumeration values Treordering_m70(7 RlcSnSize_size10~
4, bit
Radio Bearer RlcSnSize_size10(1
Treordering_m65(6 3,
Logical Channel 0ms), 1
Treordering_m75~1
Management 0bits)
5ms), Treordering_m70~1
Management Treordering_m75(7 5,
Enumeration values Treordering_m70(7 4, ms
Radio Bearer 5ms), Treordering_m80~1
Logical Channel
Management 0ms),
Treordering_m80(8 Treordering_m75~1
6,
Management Treordering_m75(7
0ms), 5,
Treordering_m85~1
Enumeration values ms
Radio Bearer 5ms),
Treordering_m85(8 Treordering_m80~1
7,
Logical Channel
Management QCI1(QCI 1),
Treordering_m80(8 6,
Management 5ms),
FALSE(FALSE), Treordering_m90~1
Enumeration values QCI2(QCI
0ms), 2), Treordering_m85~1
FALSE~0, TRUE~1 None
Radio Bearer Treordering_m90(9
MinGbrRate_0_KB(
TRUE(TRUE) 8,
MinGbrRate_0_KB
QCI3(QCI 3),
Treordering_m85(8 QCI1~1,
7, QCI2~2,
Enhanced
Management 0ms),
0KB/s), Treordering_m95~1
~0,
QCI4(QCI
5ms), 4), QCI3~3, QCI4~4,
Treordering_m90~1
Scheduling Treordering_m95(9
MinGbrRate_1_KB( 9,
MinGbrRate_1_KB
Enumeration values QCI5(QCI 5),
Treordering_m90(9
MinGbrRate_0_KB( QCI5~5,
8, QCI6~6,
MinGbrRate_0_KB None
Dynamic 5ms),
1KB/s), Treordering_m100~
~8000,
Enhanced QCI6(QCI
0ms),
0KB/s), 6), QCI7~7, QCI8~8,
Treordering_m95~1
~0,
Scheduling
PS Inter-RAT Treordering_m100(
MinGbrRate_2_KB( 20,
MinGbrRate_2_KB
Scheduling QCI7(QCI 7),
Treordering_m95(9
MinGbrRate_1_KB( QCI9~9
9,
MinGbrRate_1_KB
Mobility between E- Interval values 100ms),
2KB/s),
1~1000 Treordering_m110~
~16000,
Not involved 0.001
Dynamic QCI8(QCI
5ms),
1KB/s), 8), Treordering_m100~
~8000,
UTRAN
Enhanced and Treordering_m110(1
MinGbrRate_4KB(4 21,
MinGbrRate_4KB~
Scheduling QCI9(QCI 9)
Treordering_m100(
MinGbrRate_2_KB( 20,
MinGbrRate_2_KB
UTRAN
Scheduling 10ms),
KB/s), Treordering_m120~
32000,
PS Inter-RAT Interval values 100ms),
2KB/s),
1~1000
Treordering_m120(
MinGbrRate_8_KB( Treordering_m110~
~16000,
Not involved
22,
MinGbrRate_8_KB 0.001
Dynamic Treordering_m110(1
MinGbrRate_4KB(4 21,
MinGbrRate_4KB~
Mobility between E-
Scheduling 120ms),
8KB/s), Treordering_m130~
~64000,
Basic Scheduling 10ms),
KB/s),
Treordering_m130( Treordering_m120~
32000,
23,
UTRAN and MinGbrRate_16_K MinGbrRate_16_K
Enhanced Enumeration values Treordering_m120(
MinGbrRate_8_KB(
130ms), 22,
MinGbrRate_8_KB
Treordering_m140~ KB/s
GERAN B(16KB/s), B~128000,
Scheduling 120ms),
8KB/s),
Treordering_m140( Treordering_m130~
~64000,
24,
PS Inter-RAT
Basic Scheduling MinGbrRate_32_K MinGbrRate_32_K
Mobility between E- Treordering_m130(
MinGbrRate_16_K
140ms),
B(32KB/s), 23,
MinGbrRate_16_K
Treordering_m150~
B~256000,
Enhanced Enumeration values 130ms), Treordering_m140~ KB/s
UTRAN and B(16KB/s),
Treordering_m150(
MinGbrRate_64_K B~128000,
25,
MinGbrRate_64_K
Scheduling Treordering_m140( 24,
Basic Scheduling
CDMA2000 MinGbrRate_32_K
150ms),
B(64KB/s), MinGbrRate_32_K
Treordering_m160~
B~512000,
Enhanced
SRVCC to UTRAN Interval values 140ms),
B(32KB/s),
0~10
Treordering_m160(
MinGbrRate_128_K Treordering_m150~
B~256000,
Not
26, involved
MinGbrRate_128_K 0.1
PBR_0_KBps(0KB/
Treordering_m150(
MinGbrRate_64_K 25,
MinGbrRate_64_K
Scheduling
SRVCC to GERAN 160ms),
B(128KB/s), Treordering_m170~
B~1024000,
s),
150ms),
B(64KB/s), Treordering_m160~
B~512000,
Inter-RAT Load Treordering_m170(
MinGbrRate_256_K 27,
MinGbrRate_256_K
Interval values PBR_8_KBps(8KB/
0~39
Treordering_m160(
MinGbrRate_128_K Not
26, involved
MinGbrRate_128_K None
Sharing to UTRAN 170ms),
B(256KB/s), Treordering_m180~
B~2048000,
s),
160ms),
B(128KB/s), Treordering_m170~
B~1024000,
Inter-RAT
Basic Load
Scheduling Treordering_m180(
MinGbrRate_512_K 28,
MinGbrRate_512_K
PBR_16_KBps(16K
Treordering_m170(
MinGbrRate_256_K PBR_0_KBps~0,
27,
MinGbrRate_256_K
Sharing to GERAN
Enhanced Interval values 180ms),
B(512KB/s)
0~39 Treordering_m190~
B~4096000
Not involved None
B/s),
170ms),
B(256KB/s), PBR_8_KBps~1,
Treordering_m180~
B~2048000,
Service based inter-
Scheduling Treordering_m190( 29,
PBR_32_KBps(32K
Treordering_m180(
MinGbrRate_512_K PBR_16_KBps~2,
28,
MinGbrRate_512_K
Basic Scheduling
RAT handover to 190ms), Treordering_m200~
B/s),
180ms),
B(512KB/s) PBR_32_KBps~3,
Treordering_m190~
B~4096000
Enhanced
UTRAN Enumeration values Treordering_m200( 30 KB/s
PBR_64_KBps(64K
Treordering_m190( PBR_64_KBps~4,
29,
Scheduling
Service based inter-
Enhanced 200ms)
B/s),
190ms), PBR_128_KBps~5,
Treordering_m200~
RAT handover to
Scheduling PBR_128_KBps(12 PBR_256_KBps~6,
Interval values 9~16
Treordering_m200(
CLASS_0(CLASS_ Not involved
30 None
GERAN
Dynamic 8KB/s), PBR_INFINITY~7
CS Fallback to 200ms)
0),
Scheduling PBR_256_KBps(25
NO_ADAPTIVE(NO CLASS_0~0,
Dynamic
UTRAN CLASS_1(CLASS_
Coverage Based Enumeration values 6KB/s),
_ADAPTIVE), CLASS_1~1, None
Scheduling
CS Fallback to 1),
Inter-frequency PBR_INFINITY(Infi
OL_ADAPTIVE(OL CLASS_2~2
NO_ADAPTIVE~0,
GERAN CLASS_2(CLASS_
Handover
DL 2x2 MIMO nity)
_ADAPTIVE), OL_ADAPTIVE~1,
CS Fallback Enumeration values 2) None
PS
DL 4x2 MIMOto
Inter-RAT CL_ADAPTIVE(CL_ CL_ADAPTIVE~2,
CDMA2000 1xRTT
Mobility between E- TM2(TM2),
ADAPTIVE), OC_ADAPTIVE~3
DL 2x2
UTRAN andMIMO TM3(TM3),
OC_ADAPTIVE(OC TM2~0, TM3~1,
Enumeration values None
DL 4x2 MIMO
UTRAN TM4(TM4),
_ADAPTIVE) TM4~2, TM6~3
GAP_PATTERN_T
TM6(TM6) GAP_PATTERN_T
FC0~0, FC1~1,
PS Inter-RAT
YPE_1, YPE_1~1,
FC2~2, FC3~3,
Mobility
Coverage between
Based E- Enumeration values None
GAP_PATTERN_T
FC0, FC1, FC2, GAP_PATTERN_T
FC4~4, FC5~5,
UTRAN and
Intra-frequency
Coverage Based FC0~0,
GERAN
YPE_2
FC3, FC4, FC5, FC6~6, FC1~1,
YPE_2~2 FC7~7,
Handover
Intra-frequency FC2~2,
Coverage
PS Based
Inter-RAT Enumeration values FC6, FC7, FC8, FC8~8, FC3~3,
FC9~9, None
Coverage
Handover Based FC0,
Intra-frequency
Mobility between FC9, FC1,
FC11,FC2,
FC13, FC4~4,
FC11~10,FC5~5,
Based E-
Inter-frequency
Coverage FC3, FC0~0, FC1~1,
Handover
UTRAN and FC15,FC4, FC5,
FC17, FC19 FC6~6,
FC13~11,
FC2~2,
FC7~7,
FC3~3,
Handover
Inter-frequency Enumeration values FC6, FC7, FC8, FC8~8, FC9~9, None
Coverage
CDMA2000
PS Based
Inter-RAT FC0, FC15~12,
Handover FC9, FC1,
FC11,FC2,
FC13, FC4~4,
FC11~10,
FC17~13,
FC5~5,
FC19~14
Inter-frequency
SRVCC between
Mobility to GERAN
UTRAN E- FC3,
SRVCC to FC15,FC4, FC5,
FC17, FC19 FC6~6,
FC13~11,FC7~7,
Handover
SRVCC
UTRAN
PS to GERAN
and
Inter-RAT Enumeration values FC6, FC7, FC8, FC8~8, FC9~9, None
FC15~12,
GERAN
Mobility between E- FC9, FC11, FC13, FC11~10,
FC17~13, FC19~14
SRVCC
UTRAN andto GERAN FC15, FC17, FC19 FC13~11,
NOT_CFG~0,
Enumeration values NOT_CFG, CFG FC15~12, None
UTRAN CFG~1
PS Inter-RAT FC17~13, FC19~14
Mobility between E-
UTRAN and
GERAN
PS Inter-RAT
Mobility between E-
UTRAN and
Handover
Coverage Based
Inter-frequency
Handover
PS Inter-RAT
Mobility between E-
UTRAN and
UTRAN
Interval values -141~-44 Not involved dBm
PS Inter-RAT T_CRMAX_30S(30
Mobility between
High Speed E-
Mobility s),
UTRAN and NOT_CFG~0,
T_CRMAX_30S~0,
Ultra High Speed Enumeration values NOT_CFG, CFG
T_CRMAX_60S(60 None
GERAN T_CRMAXHYST_3 CFG~1
T_CRMAX_60S~1,
T_CRMAXHYST_3
Mobility s),
High Speed Mobility
PS Inter-RAT 0S(30s), T_CRMAX_120S~2
0S~0,
T_CRMAX_120S(1
Ultra High
Mobility Speed E-
between Enumeration values T_CRMAXHYST_6 ,T_CRMAXHYST_6 s
20s),
Mobility
UTRAN and 0S(60s), T_CRMAX_180S~3
0S~1,
High Speed Mobility T_CRMAX_180S(1
CDMA2000 T_CRMAXHYST_1 ,
T_CRMAXHYST_1
Ultra High Speed Enumeration values 80s), s
SRVCC to UTRAN 20S(120s), T_CRMAX_240S~4
20S~2,
Mobility T_CRMAX_240S(2
SRVCC to UMTS T_CRMAXHYST_1
40s) T_CRMAXHYST_1
High Speed Mobility Interval values 80S(180s),
1~16 80S~3,
Not involved None
T_CRMAXHYST_2 T_CRMAXHYST_2
High Speed Mobility 40S(240s)
TTT_SF_MEDIUM_ 40S~4
TTT_SF_MEDIUM_
Ultra High Speed Interval values 1~16
0DOT25(0.25), Not involved
0DOT25~0, None
Mobility TTT_SF_MEDIUM_ TTT_SF_MEDIUM_
TTT_SF_HIGH_0D
0DOT50(0.5), TTT_SF_HIGH_0D
0DOT50~1,
High Speed Mobility Enumeration values OT25(0.25), OT25~0, None
TTT_SF_MEDIUM_ TTT_SF_MEDIUM_
TTT_SF_HIGH_0D
0DOT75(0.75), TTT_SF_HIGH_0D
FC0~0, FC1~1,
0DOT75~2,
High Speed Mobility
OT50(0.5),
TTT_SF_MEDIUM_ OT50~1,
FC2~2, FC3~3,
TTT_SF_MEDIUM_
Ultra High Speed Enumeration values None
PS Inter-RAT TTT_SF_HIGH_0D
FC0, FC1, FC2,
LDOT0(1) TTT_SF_HIGH_0D
FC4~4,
LDOT0~3 FC5~5,
Mobility
PS Inter-RAT FC0~0,
Mobility between E- OT75(0.75),
FC3, FC4, FC5, OT75~2,FC1~1,
FC6~6, FC7~7,
Mobility between E-
PS Inter-RAT TTT_SF_HIGH_LD FC2~2, FC3~3,
TTT_SF_HIGH_LD
UTRAN and Enumeration values FC6, FC7, FC8, FC8~8, FC9~9, None
UTRAN
PS and
Inter-RAT FC0,
Handover
UTRAN between FC9, FC1,
OT0(1) FC11,FC2,
FC13, FC4~4,
OT0~3
FC11~10,FC5~5,
GERAN
Mobility between E- FC3,
LTE and
SRVCC to GERAN
UTRAN FC15,FC4,FC17,FC5,
FC19 FC6~6,
FC13~11,FC7~7,
SRVCC
UTRAN and
SRVCC to
to GERAN
GERAN Enumeration values FC6, FC7, FC8, FC8~8, FC9~9, None
FC15~12,
PS
PS Inter-RAT
UTRAN
Inter-RAT FC9, FC11, FC13, FC11~10,
FC17~13, FC19~14
Mobility
SRVCC
Handover between
to between
UTRAN E- FC15, FC17, FC19 FC13~11,
UTRAN and Interval values 1~8 120ms~0,
Not involved None
LTE and FC15~12,
CDMA2000 r1(1), r2(2), r4(4), 240ms~1,
CDMA2000 FC17~13,
r1~0, r2~1,FC19~14
r4~2,
PS
PS Inter-RAT
Inter-RAT r8(8), r16(16), 480ms~2,
PS Inter-RAT
Mobility between E- Enumeration values 120ms, r8~3, r16~4, r32~5, None
Mobility
Handover between
betweenE- r32(32), 240ms,
r64(64), 640ms~3,
UTRAN and 480ms, 640ms, r64~6, Infinity~7
1024ms~4,
UTRAN
LTE and
and UMTS Infinity(Infinity)
GERAN
UTRAN 1024ms, 2048ms, 2048ms~5,
120ms~0,
SRVCC Enumeration values None
SRVCC to
SRVCC to UMTS
to GERAN
UTRAN 5120ms, 10240ms, 5120ms~6,
240ms~1,
PS Inter-RAT
Service based inter- 1min, 6min, 12min, 10240ms~7,
Service
PS based
Inter-RAT inter- UTRAN_RSCP, UTRAN_RSCP~0,
480ms~2,
Handover
RAT between
handover to 30min, 60min 1min~8, 6min~9,
RAT Enumeration values UTRAN_ECN0, UTRAN_ECN0~1, None
LTE
GERANand UMTSto E-
handover
Mobility between 120ms, 240ms, 640ms~3,
12min~10,
UTRAN UTRAN_BOTH UTRAN_BOTH~2
SRVCC andto UMTS 480ms, 640ms, 1024ms~4,
30min~11,
Service based inter-
UTRAN 1024ms, 2048ms, 2048ms~5,
120ms~0,
Enumeration values 60min~12 None
RAT
SRVCC handover to
to UTRAN 5120ms, 10240ms, 5120ms~6,
240ms~1,
PS Inter-RAT
GERAN
Service based inter- 1min, 6min, 12min, 10240ms~7,
Mobility between 480ms~2,
RAT handover to E- Enumeration values 30min,
120ms,60min
PILOT_STRENGTH
240ms,
PILOT_STRENGTH
1min~8,
640ms~3, 6min~9, None
UTRAN
UTRAN and ~0
12min~10,
PS Inter-RAT
CDMA2000 480ms, 640ms, 1024ms~4,
Mobility between E- 1024ms, 2048ms, 30min~11,
2048ms~5,
Enumeration values 120ms~0,
60min~12 None
UTRAN and 5120ms, 10240ms, 5120ms~6,
240ms~1,
PS
PS Inter-RAT
CDMA2000
Inter-RAT 1min, 6min, 12min, 10240ms~7,
Mobility 480ms~2,
Mobility between
between E-E- Enumeration values 30min,
120ms,60min
PILOT_STRENGTH
240ms,
PILOT_STRENGTH
1min~8,
640ms~3, 6min~9, None
UTRAN
UTRAN and
and ~0
12min~10,
PS Inter-RAT
CDMA2000 480ms, 640ms, 1024ms~4,
GERAN
Mobility between E- 1024ms, 2048ms, 30min~11,
2048ms~5,
SRVCC to GERAN Enumeration values 60min~12 None
UTRAN and 5120ms, 10240ms, 5120ms~6,
PS Inter-RAT
CDMA2000 1min, 6min, 12min, 10240ms~7,
Mobility between E- RSRP,
30min, RSRQ,
60min RSRP~0, RSRQ~1,
1min~8, 6min~9,
Coverage Based Enumeration values None
UTRAN and BOTH BOTH~2
12min~10,
Intra-frequency
CDMA2000
Coverage
Handover Based 30min~11,
PS Inter-RAT
Intra-frequency Interval values 1~8 Not involved
60min~12 None
Coverage
Mobility Based E-
between
Handover
Inter-frequency r1(1), r2(2), r4(4),
UTRAN and r1~0, r2~1, r4~2,
Coverage
Handover Based r8(8), r16(16),
UTRAN Enumeration values r8~3, r16~4, r32~5, None
Inter-frequency r32(32), r64(64),
SRVCC to UTRAN r64~6, Infinity~7
Handover
Coverage Based Infinity(Infinity)
Intra-LTE Load
Intra-frequency Enumeration values RSRP, RSRQ RSRP~0, RSRQ~1 None
Balancing
Handover
120ms~0,
240ms~1,
Coverage Based SAME_AS_TRIG_ 480ms~2,
SAME_AS_TRIG_
Intra-frequency Enumeration values QUAN(Same
120ms, 240ms,as 640ms~3, None
Coverage QUAN~0, BOTH~1
Handover Based Trig Quan),
480ms, BOTH 1024ms~4,
640ms,
Intra-frequency
1024ms, 2048ms, 2048ms~5,
120ms~0,
Handover Enumeration values None
Coverage 5120ms, 10240ms, 5120ms~6,
Intra-LTE Based
Load 240ms~1,
Inter-frequency 1min, 6min, 12min, 10240ms~7,
SAME_AS_TRIG_ 480ms~2,
Balancing SAME_AS_TRIG_
Handover 30min,
120ms,60min
Enumeration values QUAN(Same as
240ms, 1min~8,
640ms~3,6min~9, None
Coverage QUAN~0, BOTH~1
Intra-LTE Based
Load Trig Quan),
480ms, BOTH 12min~10,
640ms, 1024ms~4,
Inter-frequency
Balancing 1024ms, 2048ms, 30min~11,
2048ms~5,
Handover Enumeration values None
5120ms, 10240ms, 60min~12
5120ms~6,
Intra-LTE Load
Coverage 1min, 6min, 12min, 10240ms~7,
Balancing Based RSRP, RSRQ, RSRP~0, RSRQ~1,
Inter-frequency Enumeration values 30min, 60min 1min~8, 6min~9, None
BOTH BOTH~2
12min~10,
Handover
Coverage Based 30min~11,
RSRP, RSRQ, RSRP~0, RSRQ~1,
Inter-frequency Enumeration values 60min~12 None
BOTH BOTH~2
Handover
Coverage Based 0ms~0, 40ms~1,
RSRP, RSRQ, RSRP~0, RSRQ~1,
64ms~2, 80ms~3,
Inter-frequency Enumeration values None
BOTH BOTH~2
100ms~4,
Handover
0ms, 40ms, 64ms, 0ms~0,
128ms~5,40ms~1,
3GPP R8 64ms~2, 80ms~3,
Interval values 0~11 100ms,
80ms, Not involved
160ms~6, None
Specifications 100ms~4,
128ms, 160ms, 256ms~7,
0ms~0, 40ms~1,
CS Fall Back to 0ms, 40ms,
256ms, 64ms,
320ms, 128ms~5,
320ms~8,
Enumeration values 80ms, 100ms, 64ms~2,
160ms~6, 80ms~3, ms
UMTS 480ms, 512ms, 480ms~9,
100ms~4,
128ms,
640ms, 160ms,
1024ms, 256ms~7,
512ms~10,
CS Fall Back to 0ms, 40ms,
256ms, 64ms,
320ms, 128ms~5,
320ms~8,
1280ms, 2560ms,
Enumeration values 80ms, 100ms, 640ms~11,
160ms~6, ms
GERAN 480ms,
5120ms 512ms, 480ms~9,
1024ms~12,
128ms,
640ms, 160ms,
1024ms, 256ms~7,
512ms~10,
CS Fall Back to 256ms, 320ms, 1280ms~13,
320ms~8,
Enumeration values 1280ms, 2560ms, 640ms~11,
2560ms~14, ms
1xRTT 480ms,
5120ms512ms, 480ms~9,
1024ms~12,
640ms, 1024ms, 5120ms~15
512ms~10,
CS Fall Back to 1280ms~13,
Interval values 1280ms,
-120~-25 2560ms, 640ms~11,
Not involved
2560ms~14, dBm
UMTS 5120ms 1024ms~12,
5120ms~15
CS Fall Back to 1280ms~13,
Interval values -48~0 Not involved
2560ms~14, 0.5dB
UMTS
5120ms~15
CS Fall Back to
Interval values -110~-48 Not involved dBm
GERAN
CS Fall Back to
Interval values -63~0 Not involved 0.5dB
1xRTT
3GPP R8
Interval values 0~11 Not involved None
Specifications
3GPP R8
NOT_CFG(Not
Specifications NOT_CFG~0,
Enumeration values configure), None
Broadcast of CFG~1
CFG(Configure)
P00(0%), P05(5%),
BOOLEAN_FALSE( BOOLEAN_FALSE
system information ACCESS_BARRIN
P10(10%),
False), ~0,
Emergency Call Enumeration values G_TIME_S4(4s),
P15(15%), None
BOOLEAN_TRUE( BOOLEAN_TRUE~
ACCESS_BARRIN
3GPP R8 ACCESS_BARRIN
P20(20%),
True)
NOT_CFG(Not 1
G_TIME_S4~0,
P00~0, P05~1,
Specifications G_TIME_S8(8s), NOT_CFG~0,
Enumeration values P25(25%),
configure),
ACCESS_BARRIN
ACCESS_BARRIN
P10~2, P15~3, None
Broadcast of P30(30%), CFG~1
G_TIME_S8~1,
3GPP CFG(Configure)
systemR8information G_TIME_S16(16s),
P40(40%),
P20~4, P25~5,
ACCESS_BARRIN
Specifications P30~6, P40~7,
Enumeration values ACCESS_BARRIN
P50(50%), G_TIME_S16~2, %
Broadcast of G_TIME_S32(32s), P50~8, P60~9,
3GPP P60(60%),
systemR8information ACCESS_BARRIN
ACCESS_BARRIN
P70~10, P75~11,
Specifications P70(70%), G_TIME_S32~3,
Enumeration values G_TIME_S64(64s), P80~12, P85~13, s
Broadcast of P75(75%), ACCESS_BARRIN
3GPP ACCESS_BARRIN P90~14, P95~15
systemR8information BOOLEAN_FALSE(
P80(80%), BOOLEAN_FALSE
G_TIME_S64~4,
Specifications G_TIME_S128(128
False), ~0,
Enumeration values P85(85%),
s),
ACCESS_BARRIN None
Broadcast of BOOLEAN_TRUE(
P90(90%), BOOLEAN_TRUE~
G_TIME_S128~5,
3GPP
systemR8information BOOLEAN_FALSE(
ACCESS_BARRIN
True) BOOLEAN_FALSE
1
P95(95%) ACCESS_BARRIN
Specifications False), ~0,
Enumeration values G_TIME_S256(256 G_TIME_S256~6, None
Broadcast of BOOLEAN_TRUE(
s), BOOLEAN_TRUE~
system information True) ACCESS_BARRIN
1
ACCESS_BARRIN
G_TIME_S512~7
G_TIME_S512(512
s)
3GPP R8 BOOLEAN_FALSE( BOOLEAN_FALSE
Specifications False), ~0,
Enumeration values None
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
3GPP
systemR8information BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
Specifications False), ~0,
Enumeration values None
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
3GPP P00(0%), P05(5%),
systemR8information BOOLEAN_FALSE(
True)
ACCESS_BARRIN
BOOLEAN_FALSE
1
Specifications P10(10%),
False), ~0,
Enumeration values G_TIME_S4(4s),
P15(15%), None
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
ACCESS_BARRIN
3GPP ACCESS_BARRIN
systemR8information P20(20%),
True)
NOT_CFG(Not 1
G_TIME_S4~0,
P00~0, P05~1,
Specifications G_TIME_S8(8s),
P25(25%), NOT_CFG~0,
Enumeration values configure), ACCESS_BARRIN
P10~2, P15~3, None
Broadcast of ACCESS_BARRIN
P30(30%), CFG~1
3GPP CFG(Configure) G_TIME_S8~1,
systemR8information G_TIME_S16(16s),
P40(40%),
P20~4, P25~5,
ACCESS_BARRIN
Specifications ACCESS_BARRIN P30~6, P40~7,
Enumeration values P50(50%), G_TIME_S16~2, %
Broadcast of G_TIME_S32(32s), P50~8, P60~9,
3GPP P60(60%),
systemR8information ACCESS_BARRIN
ACCESS_BARRIN
P70~10, P75~11,
Specifications P70(70%), G_TIME_S32~3,
Enumeration values G_TIME_S64(64s), P80~12, P85~13, s
Broadcast of P75(75%), ACCESS_BARRIN
3GPP ACCESS_BARRIN P90~14, P95~15
systemR8information BOOLEAN_FALSE(
P80(80%), BOOLEAN_FALSE
G_TIME_S64~4,
Specifications G_TIME_S128(128
False),
P85(85%), ~0,
Enumeration values ACCESS_BARRIN None
Broadcast of s),
BOOLEAN_TRUE(
P90(90%), BOOLEAN_TRUE~
3GPP G_TIME_S128~5,
systemR8information BOOLEAN_FALSE(
ACCESS_BARRIN
True)
P95(95%)
BOOLEAN_FALSE
1
ACCESS_BARRIN
Specifications False),
G_TIME_S256(256 ~0,
Enumeration values G_TIME_S256~6, None
Broadcast of BOOLEAN_TRUE(
s), BOOLEAN_TRUE~
3GPP
systemR8information BOOLEAN_FALSE(
True) ACCESS_BARRIN
BOOLEAN_FALSE
1
ACCESS_BARRIN
Specifications False), G_TIME_S512~7
~0,
Enumeration values G_TIME_S512(512 None
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
3GPP s)
systemR8information BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
Specifications False), ~0,
Enumeration values None
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
3GPP
systemR8information BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
Specifications False), ~0,
Enumeration values None
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
system information True) 1
3GPP R8
3GPP R8 Interval values 0~11 Not involved None
Specifications
Specifications CELL_BARRED(Ba
CELL_BARRED~0,
Broadcast of rred),
3GPP Enumeration values CELL_NOT_BARR None
systemR8information CELL_NOT_BARR
CELL_RESERVED(
Specifications ED~1
CELL_RESERVED
Cell Selection and ED(Not Barred)
Reserved),
Broadcast
Re-selectionof ~0,
3GPP Enumeration values CELL_NOT_RESE None
systemR8information CELL_NOT_RESE
Specifications RVED(Not
Cell Selection and RVED~1
Broadcast of Reserved)
ALLOWED, ALLOWED~0,
Re-selection
3GPP Enumeration values None
systemR8information NOT_ALLOWED NOT_ALLOWED~1
Specifications
Cell Selection and NORMAL_MODE(N
Broadcast
Re-selectionof ormal mode), NORMAL_MODE~
3GPP Enumeration values None
systemR8information RR_MODE(Round 0, RR_MODE~1
Specifications
Cell Selection and Robin Mode)
Broadcast
Re-selectionof
Interval values 1~720 Not involved h
system information
Cell Selection and
3GPP R8
Re-selection
3GPP R8 Interval values 0~11 Not involved None
Specifications
Specifications
Broadcast of
3GPP Interval values 0~65535 Not involved None
systemR8information CELL_RESERVED
Specifications
Cell Selection and _FOR_OP(Reserve CELL_RESERVED
Broadcast
Re-selectionof d), _FOR_OP~0,
3GPP Enumeration values None
systemR8information CELL_NOT_RESE CELL_NOT_RESE
Specifications
Cell Selection and RVED_FOR_OP(N RVED_FOR_OP~1
Broadcast
Re-selectionof ot Reserved)
3GPP R8 Interval values 1~100 Not involved %
system information
Specifications
Cell Selection and
Broadcast
Re-selectionof
Interval values 1~100 Not involved %
system information
Cell Selection and
3GPP R8
Re-selection Interval values 0~11 Not involved None
Specifications
DB2_Q_HYST~2,
DB4_Q_HYST(4dB)
DB3_Q_HYST~3,
,
DB4_Q_HYST~4,
DB5_Q_HYST(5dB)
DB5_Q_HYST~5,
,
DB6_Q_HYST~6,
DB6_Q_HYST(6dB)
DB8_Q_HYST~7,
3GPP R8 ,
DB10_Q_HYST~8,
Specifications DB8_Q_HYST(8dB)
DB12_Q_HYST~9,
Broadcast of ,
3GPP Enumeration values DB14_Q_HYST~10 dB
systemR8information DB10_Q_HYST(10
S30_T_EVALULATI S30_T_EVALULATI
Specifications ,
Cell Selection and dB),
NOT_CFG(Not
ON(30s), ON~0,
Broadcast of DB16_Q_HYST~11
NOT_CFG~0,
Re-selection
3GPP Enumeration values DB12_Q_HYST(12
configure), None
systemR8information S60_T_EVALULATI
dB),
S30_T_HYST_NOR
S60_T_EVALULATI
,
CFG~1
S30_T_HYST_NOR
Specifications CFG(Configure)
ON(60s), ON~1,
DB18_Q_HYST~12
Cell Selection and DB14_Q_HYST(14
MAL(30s), MAL~0,
Broadcast
Re-selectionof S120_T_EVALULA S120_T_EVALULA
,
3GPP Enumeration values dB), s
systemR8information S60_T_HYST_NOR
TION(120s), S60_T_HYST_NOR
TION~2,
DB20_Q_HYST~13
Specifications
Cell Selection and DB16_Q_HYST(16
MAL(60s),
S180_T_EVALULA MAL~1,
S180_T_EVALULA
,
Broadcast
Re-selectionof dB),
S120_T_HYST_NO
TION(180s), S120_T_HYST_NO
TION~3,
3GPP Enumeration values DB22_Q_HYST~14 s
systemR8information DB18_Q_HYST(18
RMAL(120s),
S240_T_EVALULA RMAL~2,
S240_T_EVALULA
Specifications ,
Cell Selection and dB),
S180_T_HYST_NO
TION(240s) S180_T_HYST_NO
TION~4
Broadcast of DB24_Q_HYST~15
Re-selection
3GPP Interval values DB20_Q_HYST(20
RMAL(180s),
1~16 RMAL~3,
Not involved None
systemR8information dB),
S240_T_HYST_NO S240_T_HYST_NO
Specifications
Cell Selection and
Broadcast of DB22_Q_HYST(22
RMAL(240s)
DB_6_Q_HYST_SF RMAL~4
DB_6_Q_HYST_SF
Re-selection
3GPP Interval values 1~16
dB), Not involved None
systemR8information _MEDIUM(-6dB), _MEDIUM~0,
Specifications
Cell Selection and DB24_Q_HYST(24
DB_4_Q_HYST_SF DB_4_Q_HYST_SF
Broadcast of DB_6_Q_HYST_SF
dB)
_MEDIUM(-4dB), DB_6_Q_HYST_SF
_MEDIUM~1,
Re-selection
3GPP Enumeration values dB
systemR8information _HIGH(-6dB),
DB_2_Q_HYST_SF _HIGH~0,
DB_2_Q_HYST_SF
Specifications
Cell Selection and DB_4_Q_HYST_SF
_MEDIUM(-2dB), DB_4_Q_HYST_SF
_MEDIUM~2,
Broadcast
Re-selectionof _HIGH(-4dB),
DB0_Q_HYST_SF_ _HIGH~1,
DB0_Q_HYST_SF_
3GPP Enumeration values dB
systemR8information DB_2_Q_HYST_SF
MEDIUM(0dB) DB_2_Q_HYST_SF
MEDIUM~3
Specifications
Cell Selection and _HIGH(-2dB), _HIGH~2,
NOT_CFG(Not
Broadcast
Re-selectionof DB0_Q_HYST_SF_ NOT_CFG~0,
DB0_Q_HYST_SF_
3GPP Enumeration values configure), None
systemR8information HIGH(0dB) CFG~1
HIGH~3
Specifications CFG(Configure)
Cell Selection and
Broadcast
Re-selectionof
3GPP Interval values 0~31 Not involved 2dB
systemR8information
Specifications
Cell Selection and
Broadcast
Re-selectionof
3GPP Interval values 0~31 Not involved 2dB
systemR8information
Specifications
Cell Selection and
Broadcast
Re-selectionof
3GPP Interval values 0~7 Not involved None
systemR8information
Specifications
Cell Selection and
Broadcast
Re-selectionof
3GPP Interval values -70~-22 Not involved 2dBm
systemR8information
Specifications
Cell Selection and NOT_CFG(Not
Broadcast
Re-selectionof NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8information CFG~1
Specifications CFG(Configure)
Cell Selection and
Broadcast
Re-selectionof
3GPP Interval values -30~33 Not involved dBm
systemR8information
Specifications
Cell Selection and NOT_CFG(Not
Broadcast
Re-selectionof NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8information CFG~1
Specifications CFG(Configure)
Cell Selection and
Broadcast
Re-selectionof
3GPP R8 Interval values 0~31 Not involved 2dB
system information
Specifications
Cell Selection and NOT_CFG(Not
Broadcast
Re-selectionof NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8information MBW6(1.4M), MBW6~0,
CFG~1
Specifications CFG(Configure)
MBW15(3M), MBW15~1,
Cell Selection and
Broadcast
Re-selectionof MBW25(5M), MBW25~2,
3GPP R8 Enumeration values MHz
system information MBW50(10M), MBW50~3,
Specifications
Cell Selection and MBW75(15M), MBW75~4,
Broadcast
Re-selectionof MBW100(20M) MBW100~5
3GPP Interval values 0~7 Not involved s
systemR8information
Specifications
Cell Selection and NOT_CFG(Not
T_RESEL_SF_0DO T_RESEL_SF_0DO
Broadcast
Re-selectionof NOT_CFG~0,
3GPP R8 Enumeration values configure),
T25(0.25), T25~0, None
system information CFG~1
Specifications CFG(Configure)
T_RESEL_SF_0DO T_RESEL_SF_0DO
Cell Selection and T_RESEL_SF_0DO T_RESEL_SF_0DO
Broadcast
Re-selectionof T5(0.5), T5~1,
3GPP Enumeration values T25(0.25), None
systemR8information T_RESEL_SF_0DO T25~0,
T_RESEL_SF_0DO
Specifications
Cell Selection and T_RESEL_SF_0DO
T75(0.75), T_RESEL_SF_0DO
T75~2,
Broadcast
Re-selectionof T5(0.5), T5~1,
Enumeration values T_RESEL_SF_1DO T_RESEL_SF_1DO None
system information T_RESEL_SF_0DO
T0(1.0) T_RESEL_SF_0DO
T0~3
Cell Selection and T75(0.75), T75~2,
Re-selection T_RESEL_SF_1DO T_RESEL_SF_1DO
T0(1.0) T0~3
3GPP R8
Specifications BitString00(00), BitString00~0,
Broadcast of BitString01(01), BitString01~1,
3GPP Enumeration values None
systemR8 information BitString10(10), BitString10~2,
Specifications
Cell Selection and BOOLEAN_FALSE(
BitString11(11) BOOLEAN_FALSE
BitString11~3
Broadcast
Re-selection of False), ~0,
Enumeration values None
system information BOOLEAN_TRUE( BOOLEAN_TRUE~
Cell Selection and True) 1
3GPP R8
Re-selection
3GPP R8 Interval values 0~11 Not involved None
Specifications
Specifications
NOT_CFG(Not
Broadcast of NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8 information CFG~1
Specifications CFG(Configure)
BOOLEAN_FALSE( BOOLEAN_FALSE
Cell Selection and
Broadcast
Re-selection of False), ~0,
3GPP Enumeration values None
systemR8 information BOOLEAN_TRUE( BOOLEAN_TRUE~
Specifications
Cell Selection and True) 1
NOT_CFG(Not
Broadcast
Re-selection of NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8 information CFG~1
Specifications CFG(Configure)
Cell Selection and
Broadcast
Re-selection of
3GPP Interval values 0~15 Not involved None
systemR8 information
Specifications
Cell Selection and NOT_CFG(Not
Broadcast
Re-selection of NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8 information CFG~1
Specifications CFG(Configure)
Cell Selection and NOT_CFG(Not
Broadcast
Re-selection of NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8 information CFG~1
Specifications CFG(Configure)
BOOLEAN_FALSE( BOOLEAN_FALSE
Cell Selection and
Broadcast
Re-selection of False), ~0,
3GPP Enumeration values None
systemR8 information BOOLEAN_TRUE( BOOLEAN_TRUE~
Specifications
Cell Selection and True) 1
Broadcast
Re-selection of
3GPP Interval values 0~255 Not involved None
systemR8 information
Specifications
Cell Selection and NOT_CFG(Not
Broadcast
Re-selection of NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8 information CFG~1
Specifications CFG(Configure)
Cell Selection and
Broadcast
Re-selection of
3GPP Interval values 0~255 Not involved None
systemR8 information
Specifications
Cell Selection and NOT_CFG(Not
Broadcast
Re-selection of NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8 information CFG~1
Specifications CFG(Configure)
Cell Selection and
Broadcast
Re-selection of
3GPP Interval values 0~255 Not involved None
systemR8 information
Specifications
Cell Selection and
Broadcast
Re-selection of
3GPP Interval values 0~7 Not involved s
systemR8 information
Specifications
Cell Selection and NOT_CFG(Not
T_RESEL_SF_0DO T_RESEL_SF_0DO
Broadcast
Re-selection of NOT_CFG~0,
3GPP R8 Enumeration values configure),
T25(0.25), T25~0, None
system information CFG~1
Specifications CFG(Configure)
T_RESEL_SF_0DO T_RESEL_SF_0DO
Cell Selection and T_RESEL_SF_0DO T_RESEL_SF_0DO
Broadcast
Re-selection of T5(0.5), T5~1,
3GPP Enumeration values T25(0.25), None
systemR8 information T_RESEL_SF_0DO T25~0,
T_RESEL_SF_0DO
Specifications
Cell Selection and T_RESEL_SF_0DO
T75(0.75), T_RESEL_SF_0DO
T75~2,
Broadcast
Re-selection of T5(0.5), T5~1,
3GPP R8 Enumeration values T_RESEL_SF_1DO T_RESEL_SF_1DO None
system information T_RESEL_SF_0DO
T0(1.0) T_RESEL_SF_0DO
T0~3
Specifications
Cell Selection
3GPP R8 of and
Broadcast
T75(0.75),
NOT_CFG(Not T75~2,
NOT_CFG~0,
Re-selection
Specifications Enumeration values T_RESEL_SF_1DO
configure), T_RESEL_SF_1DO None
system information T0(1.0) CFG~1
T0~3
Broadcast of and CFG(Configure)
Cell
3GPP Selection
R8 NOT_CFG(Not
system information
Re-selection NOT_CFG~0,
Specifications Enumeration values configure), None
Cell Selection and CFG~1
Broadcast of CFG(Configure)
Re-selection
3GPP R8
system
CS information
Fall Back to 1x
Specifications Interval values 0~32767 Not involved None
Cell
RTT Selection and
Broadcast
Re-selection of
system information
CS Fall Back to 1x Interval values 0~65535 Not involved None
Cell
RTT Selection and
Re-selection
CS Fall Back to 1x
RTT
3GPP R8
Specifications
Broadcast of BOOLEAN_FALSE( BOOLEAN_FALSE
3GPP
systemR8 information False), ~0,
Specifications Enumeration values None
Cell Selection and BOOLEAN_TRUE( BOOLEAN_TRUE~
Broadcast
Re-selection of BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
3GPP
system R8information False), ~0,
CS Fall Back to 1x
Specifications Enumeration values None
Cell
RTT Selection and BOOLEAN_TRUE( BOOLEAN_TRUE~
Broadcast
Re-selection of BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
3GPP
system R8information False), ~0,
CS Fall Back to 1x
Specifications Enumeration values None
Cell Selection and
RTT BOOLEAN_TRUE( BOOLEAN_TRUE~
Broadcast
Re-selection of BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
3GPP
system R8information False), ~0,
CS Fall Back to 1x
Specifications Enumeration values None
Cell
RTT Selection and BOOLEAN_TRUE( BOOLEAN_TRUE~
Broadcast
Re-selection of BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
3GPP
system R8information False), ~0,
CS Fall Back to 1x
Specifications Enumeration values None
Cell Selection and
RTT BOOLEAN_TRUE( BOOLEAN_TRUE~
Broadcast
Re-selection of BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
3GPP
system R8information False), ~0,
CS Fall Back to 1x
Specifications Enumeration values None
Cell
RTT Selection and BOOLEAN_TRUE( BOOLEAN_TRUE~
Broadcast
Re-selection of BOOLEAN_FALSE(
True) BOOLEAN_FALSE
1
3GPP
system R8information False), ~0,
CS Fall Back to 1x
Specifications Enumeration values None
Cell Selection and
RTT BOOLEAN_TRUE( BOOLEAN_TRUE~
Broadcast
Re-selection of True) 1
3GPP
system R8information
CS Fall Back to 1x
Specifications Interval values 0~127 Not involved None
Cell
RTT Selection and
Broadcast
Re-selection of
3GPP
system R8information
CS Fall Back to 1x
Specifications Interval values 0~4095 Not involved None
Cell Selection and
RTT
Broadcast
Re-selection of
3GPP
system R8information
CS Fall Back to 1x
Specifications Interval values 0~7 Not involved None
Cell
RTT Selection and
Broadcast
Re-selection of
system
CS information
FallR8
Back to 1x
3GPP Interval values 0~7 Not involved None
Cell
RTT Selection and
Specifications
Re-selection NOT_CFG(Not
Broadcast
CS FallR8
Backof to 1x NOT_CFG~0,
3GPP Enumeration values configure), None
system
RTT information CFG~1
Specifications CFG(Configure)
Cell Selection and
Broadcast
Re-selection of
3GPP Character string 0~6 characters Not involved None
systemR8 information
Specifications
Cell Selection and NOT_CFG(Not
Broadcast
Re-selection of NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8 information CFG~1
Specifications CFG(Configure)
Cell Selection and
Broadcast
Re-selection of
3GPP Interval values 0~7 Not involved s
systemR8 information
Specifications
Cell Selection and NOT_CFG(Not
T_RESEL_SF_0DO T_RESEL_SF_0DO
Broadcast
Re-selection of NOT_CFG~0,
3GPP Enumeration values configure), None
systemR8 information T25(0.25), T25~0,
CFG~1
Specifications CFG(Configure)
T_RESEL_SF_0DO T_RESEL_SF_0DO
Cell Selection and T_RESEL_SF_0DO T_RESEL_SF_0DO
Broadcast
Re-selection of T5(0.5), T5~1,
3GPP R8 Enumeration values T25(0.25), T25~0, None
system information T_RESEL_SF_0DO T_RESEL_SF_0DO
Specifications
Cell Selection and T_RESEL_SF_0DO
T75(0.75), T_RESEL_SF_0DO
T75~2,
Broadcast
Re-selection of T5(0.5), T5~1,
Enumeration values T_RESEL_SF_1DO T_RESEL_SF_1DO None
system information T_RESEL_SF_0DO
T0(1.0) T_RESEL_SF_0DO
T0~3
Cell Selection and T75(0.75), T75~2,
3GPP R8
Re-selection T_RESEL_SF_1DO T_RESEL_SF_1DO
3GPP R8 Interval values 0~11 Not involved None
Specifications T0(1.0) T0~3
Specifications
3GPP R8 of
Broadcast
Specifications Interval values 0~7 Not involved s
system information
Broadcast
Cell of and
Selection
3GPP R8 NOT_CFG(Not
T_RESEL_SF_0DO T_RESEL_SF_0DO
system information
Re-selection NOT_CFG~0,
Specifications Enumeration values configure),
T25(0.25), T25~0, None
Cell Selection and CFG~1
Broadcast of CFG(Configure)
T_RESEL_SF_0DO T_RESEL_SF_0DO
Re-selection
3GPP R8 T_RESEL_SF_0DO T_RESEL_SF_0DO
system
Mobility information T5(0.5), T5~1,
Specifications Enumeration values T25(0.25), T25~0, None
Cell Selection and
Management T_RESEL_SF_0DO T_RESEL_SF_0DO
Broadcast
Re-selection of T_RESEL_SF_0DO
T75(0.75), T_RESEL_SF_0DO
T75~2,
system
Mobility information T5(0.5), T5~1,
Enumeration values T_RESEL_SF_1DO T_RESEL_SF_1DO None
Cell Selection and
Management T_RESEL_SF_0DO
T0(1.0) T_RESEL_SF_0DO
T0~3
Re-selection T75(0.75), T75~2,
Mobility T_RESEL_SF_1DO T_RESEL_SF_1DO
Management T0(1.0) T0~3
3GPP R8
3GPP R8 Interval values 0~11 Not involved None
Specifications
Specifications
3GPP R8 of
Broadcast
Specifications Interval values 0~7 Not involved s
system information
Broadcast
Cell of and
Selection
3GPP R8 NOT_CFG(Not
T_RESEL_SF_0DO T_RESEL_SF_0DO
system information
Re-selection NOT_CFG~0,
Specifications Enumeration values configure),
T25(0.25), T25~0, None
Cell Selection and CFG~1
Broadcast of CFG(Configure)
T_RESEL_SF_0DO T_RESEL_SF_0DO
Re-selection
3GPP R8 T_RESEL_SF_0DO T_RESEL_SF_0DO
system
Mobility information T5(0.5), T5~1,
Specifications Enumeration values T25(0.25), T25~0, None
Cell Selection and
Management T_RESEL_SF_0DO T_RESEL_SF_0DO
Broadcast
Re-selection of T_RESEL_SF_0DO
T75(0.75), T_RESEL_SF_0DO
T75~2,
system
Mobility information T5(0.5), T5~1,
Enumeration values T_RESEL_SF_1DO T_RESEL_SF_1DO None
Cell Selection and
Management T_RESEL_SF_0DO
T0(1.0) T_RESEL_SF_0DO
T0~3
Re-selection T75(0.75), T75~2,
3GPP R8
Mobility T_RESEL_SF_1DO T_RESEL_SF_1DO
3GPP R8 Interval values 0~11 Not involved None
Specifications
Management T0(1.0) T0~3
Specifications
Broadcast of
3GPP Interval values -70~-22 Not involved 2dBm
systemR8information
Specifications
Cell Selection and
Broadcast
Re-selectionof
Interval values 0~8 Not involved 2dB
system information
Cell Selection and
3GPP R8
Re-selection Interval values 0~11
RF8(8 radio Not involved None
Specifications
3GPP R8 BOOLEAN_FALSE(
frames), RF16(16 BOOLEAN_FALSE
Specifications False),
radio frames), ~0,
Enumeration values RF8(8 radio None
Broadcast of BOOLEAN_TRUE(
RF32(32 radio BOOLEAN_TRUE~
3GPP
systemR8information frames),
True) RF16(16 RF8~0,
1 RF16~1,
frames), RF64(64
Specifications radio frames), RF32~2, RF64~3,
Enumeration values radio
RF8(8 frames),
radio None
Broadcast of RF32(32 radio RF128~4,
3GPP RF128(128 radio
systemR8information frames),
frames), RF16(16
RF64(64
RF8~0,
RF256~5,RF16~1,
RF512~6
Specifications frames),
radio RF256(256
frames), RF32~2, RF64~3,
Enumeration values radio
radio
RF8(8 frames),
frames),
radio None
Broadcast of RF32(32 radio RF128~4,
3GPP RF128(128 radio
systemR8information RF512(512
frames),
frames), radio
RF16(16
RF64(64
RF8~0,
RF256~5,RF16~1,
RF512~6
Specifications frames),
frames)
radio RF256(256
frames), RF32~2, RF64~3,
Enumeration values radio
radio
RF8(8 frames),
frames),
radio None
Broadcast of RF32(32 radio RF128~4,
3GPP RF128(128 radio
systemR8information RF512(512
frames),
frames), radio
RF16(16
RF64(64
RF8~0,
RF256~5,RF16~1,
RF512~6
Specifications frames),
frames)
radio RF256(256
frames), RF32~2, RF64~3,
Enumeration values radio
radio
RF8(8 frames),
frames),
radio None
Broadcast of RF32(32 radio RF128~4,
3GPP RF128(128 radio
systemR8information RF512(512
frames),
frames), radio
RF16(16
RF64(64
RF8~0,
RF256~5,RF16~1,
RF512~6
Specifications frames),
frames)
radio RF256(256
frames), RF32~2, RF64~3,
Enumeration values radio
radio
RF8(8 frames),
frames),
radio None
Broadcast of RF32(32 radio RF128~4,
3GPP RF128(128 radio
systemR8information RF512(512
frames),
frames), radio
RF16(16
RF64(64
RF8~0,
RF256~5,RF16~1,
RF512~6
Specifications frames),
frames)
radio RF256(256
frames), RF32~2, RF64~3,
Enumeration values radio
radio frames),
frames), None
Broadcast of RF32(32 radio RF128~4,
3GPP RF128(128 radio
systemR8information RF512(512
frames), radio
RF64(64
RF8~0,
RF256~5,RF16~1,
RF512~6
Specifications frames),
frames) RF256(256 RF32~2, RF64~3,
Enumeration values radio
radio frames),
frames), None
Broadcast of RF128~4,
RF128(128
RF512(512 radio
radio
system information RF256~5, RF512~6
3GPP R8 frames),
frames) RF256(256
3GPP R8 Interval values 0~11
AL0(0), AL04(0.4),
radio frames), Not involved None
Specifications
Specifications AL05(0.5),
RF512(512 radio AL0~0, AL04~1,
Broadcast of AL06(0.6),
frames) AL05~2, AL06~3,
3GPP Enumeration values None
systemR8information AL07(0.7), AL07~4, AL08~5,
Specifications
Uplink Power AL08(0.8), AL09~6, AL1~7
Broadcast
Control of AL09(0.9),
3GPP Interval values -127~-96 AL1(1) Not involved dBm
systemR8information
Specifications
Uplink Power
Broadcast
Control of
3GPP R8 Interval values -126~24 Not involved dBm
system information
Specifications
Uplink Power DELTAF_2(-2dB), DELTAF_2~0,
Broadcast
Control of
3GPP Enumeration values DELTAF0(0dB), DELTAF0~1, dB
systemR8information
Specifications DELTAF2(2dB) DELTAF2~2
Uplink Power DELTAF1(1dB), DELTAF1~0,
Broadcast
Control of
Enumeration values DELTAF3(3dB), DELTAF3~1, dB
system information
DELTAF5(5dB) DELTAF5~2
Uplink Power
Control
3GPP R8
Specifications DELTAF_2(-2dB), DELTAF_2~0,
Broadcast of DELTAF0(0dB), DELTAF0~1,
3GPP Enumeration values dB
systemR8information DELTAF1(1dB), DELTAF1~2,
Specifications
Uplink Power DELTAF2(2dB) DELTAF2~3
DELTAF_2(-2dB), DELTAF_2~0,
Broadcast
Control of
3GPP Enumeration values DELTAF0(0dB), DELTAF0~1, dB
systemR8information
Specifications DELTAF2(2dB) DELTAF2~2
Uplink Power DELTAF_2(-2dB), DELTAF_2~0,
Broadcast
Control of
3GPP Enumeration values DELTAF0(0dB), DELTAF0~1, dB
systemR8information MS100_T300(100m
Specifications DELTAF2(2dB) DELTAF2~2
Uplink Power s),
Broadcast
Control of MS200_T300(200m
Interval values -1~6 Not involved 2dB
system information MS100_T301(100m
s),
Uplink Power s),
MS300_T300(300m MS100_T300~0,
3GPP
ControlR8 MS200_T301(200m
Interval values 0~11
s), Not involved
MS200_T300~1, None
Specifications s),
3GPP R8 MS400_T300(400m MS300_T300~2,
Specifications MS300_T301(300m
s), MS100_T301~0,
MS400_T300~3,
Enumeration values MS0_T310(0ms),
s), MS200_T301~1, ms
Broadcast of MS600_T300(600m
MS50_T310(50ms), MS600_T300~4,
3GPP
systemR8information MS400_T301(400m
s),
MS1000_T311(100 MS300_T301~2,
MS1000_T300~5,
Specifications MS100_T310(100m
s), MS400_T301~3,
Enumeration values MS1000_T300(100
0ms), MS0_T310~0,
MS1500_T300~6, ms
Broadcast of s),
MS600_T301(600m MS600_T301~4,
0ms),
MS3000_T311(300 MS50_T310~1,
MS2000_T300~7
3GPP
systemR8information MS200_T310(200m
s), MS1000_T301~5,
MS1500_T300(150
0ms), MS100_T310~2,
Specifications s),
MS1000_T301(100 MS1000_T311~0,
MS1500_T301~6,
Enumeration values 0ms),
MS5000_T311(500 MS200_T310~3, ms
Broadcast of MS500_T310(500m
0ms), MS3000_T311~1,
MS2000_T301~7
3GPP MS2000_T300(200 MS500_T310~4,
systemR8information 0ms),
s),
MS1500_T301(150 MS5000_T311~2,
Specifications 0ms)
MS10000_T311(10 MS1000_T310~5,
Enumeration values MS1000_T310(100
0ms), MS10000_T311~3, ms
Broadcast of 000ms), MS2000_T310~6
3GPP 0ms),
MS2000_T301(200 MS15000_T311~4,
systemR8information MS15000_T311(15
n1(1), n2(2), n3(3),
MS2000_T310(200 n1~0, n2~1, n3~2,
Specifications 0ms) MS20000_T311~5,
Enumeration values 000ms),
n4(4),
0ms) n5(5), n6(6), n4~3, n5~4, n6~5, None
Broadcast of MS30000_T311~6
3GPP MS20000_T311(20
n8(8), n10(10) n8~6, n10~7
systemR8information n1(1),
000ms),n2(2), n3(3), n1~0, n2~1, n3~2,
Specifications
Enumeration values n4(4), n6(6), n8(8),
MS30000_T311(30 n4~3, n6~4, n8~5, None
Broadcast of
n10(10),
000ms) n20(20) n10~6, n20~7
system information
None Interval values 0~11 Not involved None

None Character string 1~99 characters Not involved None

None Interval values 0~11 Not involved None


BOOLEAN_FALSE( BOOLEAN_FALSE
Broadcast of False), ~0,
Enumeration values None
system information
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
NORMAL_CP(Nor
True) 1
system information
mal), NORMAL_CP~0,
CP length Enumeration values None
EXTENDED_CP(Ex EXTENDED_CP~1
Normal CP NORMAL_CP(Nor
CP length tended)
Extended CP mal), NORMAL_CP~0,
Normal CP Enumeration values None
EXTENDED_CP(Ex EXTENDED_CP~1
Extended CP
tended)
Broadcast of
Interval values 1~40,64 Not involved None
system information
NOT_CFG(Not
Broadcast of NOT_CFG~0,
Enumeration values configure), None
system information CFG~1
CFG(Configure)
Broadcast of 18000~39649,6533
CELL_BW_N6(1.4
Interval values Not involved None
system information 6~65535
M),
Broadcast of CELL_BW_N15(3M
0~39649,65336~65
Interval values CELL_BW_N6(1.4
), Not involved
CELL_BW_N6~0, None
system information 535
M),
CELL_BW_N25(5M CELL_BW_N15~1,
Scalable Bandwidth CELL_BW_N15(3M
), CELL_BW_N25~2,
Broadcast of Enumeration values ), CELL_BW_N6~0, MHz
CELL_BW_N50(10 CELL_BW_N50~3,
system information CELL_BW_N25(5M CELL_BW_N15~1,
Scalable Bandwidth M), CELL_BW_N75~4,
),
CELL_BW_N75(15 CELL_BW_N25~2,
CELL_BW_N100~5 MHz
Broadcast of Enumeration values
CELL_BW_N50(10
M), CELL_BW_N50~3,
system information
M),
CELL_BW_N100(2 CELL_BW_N75~4,
CELL_BW_N75(15
0M) CELL_BW_N100~5
M),
CELL_BW_N100(2
0M)
E(Unavailable MPT
board),
GET_LICENSE_FAI
L(Failed to obtain
the cell license),
TDD_CELL_FRAM
E_CFG_ERR(Incorr
Broadcast of ect TDD uplink-
Interval values 0~255
downlink subframe Not involved None
system information
configuration in a
Broadcast of baseband
Interval values 0~503 Not involved None
system information processing unit),
CELL_POWER_EX
Broadcast of
Interval values 1~32
CEED_RRU_CAP( Not involved None
system information
User-configured
CELL_DEACTIVE(
CELL_UNBLOCK(U
maximum
Deactivated), cell TX CELL_UNBLOCK~
CELL_DEACTIVE~
None Enumeration values nblock),
power exceeding 0,
CELLINFO_INIT_F None
CELL_ACTIVE(Acti 0, CELL_ACTIVE~1
CELL_HIGH_BLOC
the
ve) allowed power CELL_HIGH_BLOC
AIL~0,
K(High
range ofblock),
dB-24(-24dB),RRU),dB- K~1,
ALLOC_RRU_FAIL
None Enumeration values None
CELL_MIDDLE_BL
INTRA_BBI_PREA
22(-22dB), dB-20(- CELL_MIDDLE_BL
~1,
OCK(Middle
MBLEFMT_CFG_E
20dB), dB-18(- block), OCK~2,
ALLOC_BBI_FAIL~
None Interval values CELL_LOW_BLOC
dB-24(-24dB),
1~1440dB-16(-dB-
RR(Inconsistent
18dB), CELL_LOW_BLOC
Not involved
2, min
K(Low
16dB), block)
22(-22dB),
preamble dB-20(-
format
dB-14(- of K~3
ALLOC_IDX2_FAIL
Broadcast of 20dB),
a cell indB-18(-
a
CELL_FDD(FDD),
14dB), baseband
dB-12(- ~3,
CELL_FDD~0,
Enumeration values SA0(SA0), None
system information 18dB),
processingdB-16(-
CELL_TDD(TDD)
12dB), unit),
dB-10(- RES_CHK_FAIL~4,
CELL_TDD~1
dB-24~0, dB-22~1,
SA1(SA1),
16dB), dB-14(-
INTRA_BBI_CYCLI
SSP0(SSP0),
10dB), dB-8(-8dB), SA0~0,
dB-20~2,SA1~1,
UEM_CFG_FAIL~5,
dB-18~3,
SA2(SA2),
Broadcast of 14dB), dB-12(-
CPREFIX_CFG_ER
SSP1(SSP1),
dB-6(-6dB), SA2~2,
dB-16~4,SA3~3,
RRU_CFG_FAIL~6,
Enumeration values SA3(SA3), dB-5(- dB-14~5, None
system information 12dB), dB-10(-
R(Inconsistent
SSP2(SSP2),
5dB), dB-4(-4dB), SA4~4,
SSP0~0,SA5~5,
dB-24~0, dB-22~1,
BBI_CFG_FAIL~7,
dB-12~6, SSP1~1,
dB-10~7,
SA4(SA4),
10dB), dB-8(-8dB),
uplink/downlink
SSP3(SSP3),
dB-3(-3dB), CP SA6~6
dB-20~2, dB-18~3,
TX_BRANCH_NOT
SSP2~2, SSP3~3,
Broadcast of SA5(SA5), dB-2(- dB-8~8, dB-6~9,
Enumeration values dB-6(-6dB),
length
SSP4(SSP4),
2dB), dB-5(-
dB-1(-1dB),a
of a cell in dB-16~4,
dB-5~10, dB-14~5,
_USABLE~8,
SSP4~4, SSP5~5,
dB-4~11, None
system information SA6(SA6)
5dB),
basebanddB-4(-4dB),
SSP5(SSP5),
dB0(0dB), dB-12~6, dB-10~7,
RX_BRANCH_NOT
SSP6~6, SSP7~7,
dB-3~12, dB-2~13,
dB-3(-3dB),
processing
SSP6(SSP6),
dB1(1dB), dB-2(-
unit), dB-8~8,
SSP8~8 dB-6~9,
_USABLE~9,
dB-1~14, dB0~15,
None Enumeration values 2dB), dB-1(-1dB),
BBI_CELL_NUM_O
SSP7(SSP7), dB-5~10, dB-4~11,
CELL_FREQ_ERR dB
dB2(2dB), dB1~16, dB2~17,
dB0(0dB),
VER(Cell
SSP8(SSP8)
dB3(3dB), dB-3~12,
OR~10, dB-2~13,
dB3~18, dB4~19,
dB1(1dB),
configurations
dB4(4dB), dB-1~14, dB0~15,
CELL_ACT_SUCC
dB5~20, dB6~21,
None Enumeration values dB
dB2(2dB),
exceeding
dB5(5dB), the dB1~16,
dB8~22, dB2~17,
ESS~11, dB10~23,
dB3(3dB),
specifications
dB6(6dB), of the dB3~18,
dB12~24,dB4~19,
NO_INFO~12,dB14~25,
Random Access LOW_SPEED(Low
dB4(4dB),
baseband board), dB5~20, dB6~21,
S1_LINK_DOWN~1
Interval values 0~837
dB8(8dB), Not involved
dB16~26, dB18~27, None
Procedure speed
dB5(5dB),cell flag), dB8~22,
CELL_EXCEED_D
dB10(10dB), dB20~28,dB10~23,
3, dB22~29,
LOW_SPEED~0,
High Speed Mobility HIGH_SPEED(High
dB6(6dB), dB12~24,
SP_SPEC(Cell
dB12(12dB), dB24~30 dB14~25,
ALLOC_CONTAINE
HIGH_SPEED~1,
Ultra High Speed Enumeration values speed
dB8(8dB),cell flag),
configurations dB16~26,
R_FAIL~14, dB18~27, None
dB14(14dB), ULTRA_HIGH_SPE
Mobility ULTRA_HIGH_SPE
CELL_NO_OP(No
dB10(10dB),
exceeding the dB20~28, dB22~29,
MPT_NOT_USABL
dB16(16dB), ED~2
Random Access ED(Ultra
Operation),
dB12(12dB), high of the
specifications dB24~30
E~15,
Interval values dB18(18dB),
0~4 Not involved None
Procedure speed cell flag)
CELL_SETUP_ACT
dB14(14dB),
baseband GET_LICENSE_FAI
dB20(20dB),
(Act Cell),
dB16(16dB),
processing),
dB22(22dB), L~16,
Random Access CELL_SETUP_UBL
dB18(18dB),
MULTI_CARRIER_ TDD_CELL_FRAM
Interval values 1~100000
dB24(24dB) Not involved m
Procedure (UnBlock
dB20(20dB),
CELL_TOPO_NOT Cell), E_CFG_ERR~17,
NOT_CFG(Not CELL_NO_OP~0,
CELL_INST_UNIN
CELL_SETUP_HE
dB22(22dB),
_SPT(A multi- CELL_POWER_EX
NOT_CFG~0,
CELL_SETUP_ACT
None Enumeration values configure),
STALL(Uninstall),
ALCHK(Cell
dB24(24dB)
carrier cell CEED_RRU_CAP~ None
CFG~1
CELL_INST_UNIN
~1,
CFG(Configure)
CELL_INST_UEM_
Healthy
supporting Check),
only 18,
STALL~0,
CELL_SETUP_UBL
CFGING(UEM
CELL_SETUP_141
RRUs in star INTRA_BBI_PREA
None Interval values 98 CELL_INST_UEM_
~2,
Not involved 0.1MHz
configuring),
(141 Cell or
topology Setup),
two MBLEFMT_CFG_E
CFGING~1,
CELL_SETUP_HE
CELL_INST_RRU_
CELL_SETUP_UL
combined RRUs), RR~19,
CELL_INST_RRU_
ALCHK~3,
None Interval values CFGING(RRU 98
WIDESCAN(UL
BF_ALGO_NOT_S INTRA_BBI_CYCLI
Not involved 0.1MHz
CFGING~2,
CELL_SETUP_141
configuring),
Wide Freq Scan
UPPORT(The CPREFIX_CFG_ER
CELL_INST_BBI_C
~4,
CELL_INST_BBI_C
Cell Setup),
baseband version R~20,
FGING~3,
CELL_SETUP_UL
None Enumeration values FGING(BBI
CELL_DEL_BLK_L
not supporting the BBI_CELL_NUM_O None
CELL_INST_RECF
WIDESCAN~5,
configuring),
OW(Block
BF Cell
algorithm), VER~21,
GING~4,
CELL_DEL_BLK_L
CELL_INST_RECF
Low),
BBI_MIMOCELL_B CELL_EXCEED_D
None Enumeration values CELL_INST_DELE
OW~26, None
GING(Recfging),
CELL_DEL_BLK_M
W_ERR(MIMO SP_SPEC~22,
TING~5,
CELL_DEL_BLK_M
CELL_INST_DELE
ID(Block
mutual aid Cell Mid), MULTI_CARRIER_
CELL_INST_NORM
ID~27,
None Character string TING(Deleting),
CELL_DEL_BLK_H
supporting
0~32 characters only the CELL_TOPO_NOT
Not involved None
AL~6,
CELL_DEL_BLK_H
CELL_INST_NORM
IGH(Block
cell bandwidth Cell of 10 _SPT~23,
CELL_INST_BARR
IGH~28,
AL(Normal),
High),
MHz or higher), BF_ALGO_NOT_S
ED~7
CELL_DEL_NOUS
None Enumeration values CELL_INST_BARR
CELL_DEL_NOUS
MIMOCELL_BW_M UPPORT~24, None
ER~29,
ED(Barred)
ER(Block
IX_ERR(MIMO Cell No BBI_MIMOCELL_B
CELL_DEL_DEA~3
User),
mutual aid not W_ERR~25,
None Character string 0~32 characters 0,
Not involved None
CELL_DEL_DEA(D
supporting hybrid MIMOCELL_BW_M
CELL_DEL_RMV~3
eactive
bandwidth),Cell), IX_ERR~26,
1,
CELL_DEL_RMV(D
MIMOCELL_TOPO MIMOCELL_TOPO
CELl_DEL_HEALC
elete Cell),
_MIX_ERR(Coexist _MIX_ERR~27,
HK~32,
CELl_DEL_HEALC
ence not allowed DOUBLERRU_10M
CELL_DEL_UNHE
HK(Cell
betweenHealthy
MIMO BL_BW_MIX_ERR
AL~33,
Chk),
mutual aid and ~28,
CELL_DEL_SETUP
CELL_DEL_UNHE
other network DOUBLERRU_TOP
_FAIL~34,
CELL_DEL_BLK_L
E(Star basic Type),
Shutdown WIDESCAN~5,
OW(Block Mode),
HOT_BACKUP_TY Cell CELL_PWRSAVE_
CELL_PWRSAVE_ CELL_DEL_BLK_L
Low), Backup
PE(Hot UNINSTALL~0,
LOWPWR_CELLU OW~26,
CELL_DEL_BLK_M
Type), CELL_PWRSAVE_
SEDPWRRDU(Low CELL_DEL_BLK_M
ID(Block Cell Mid),
COLD_BACKUP_T STAR_BASIC_TYP
RFSHD~1,
Power ID~27,
CELL_DEL_BLK_H
YPE(Cold Backup E~0,
CELL_PWRSAVE_
Consumption CELL_DEL_BLK_H
IGH(Block Cell
Type), HOT_BACKUP_TY
CELLSHD~2,
Mode-Cell Used IGH~28,
High),
MULTI_CHAIN_TY PE~1,
CELL_PWRSAVE_
Power Reduced), CELL_DEL_NOUS
None Enumeration values CELL_DEL_NOUS
PE(MuLti Chain COLD_BACKUP_T
LOWPWR_CELLU None
CELL_PWRSAVE_ ER~29,
ER(Block
Type), Cell No
BBI_SLOT_0(0), YPE~2,
SEDPWRRDU~3,
LOWPWR_RSPWR CELL_DEL_DEA~3
BBI_SLOT_0~0,
User),
STAR_DOUBLE_R
BBI_SLOT_1(1), MULTI_CHAIN_TY
CELL_PWRSAVE_
None Enumeration values RDU(Low Power 0,
BBI_SLOT_1~1, None
CELL_DEL_DEA(D
RU_TYPE(Star
BBI_SLOT_2(2), PE~3,
LOWPWR_RSPWR
Consumption CELL_DEL_RMV~3
BBI_SLOT_2~2,
eactive
Double Cell),
RRU
BBI_SLOT_3(3), Type), STAR_DOUBLE_R
RDU~4,
Mode-Reference 1,
BBI_SLOT_3~3,
None Enumeration values CELL_DEL_RMV(D
CHAIN_LEVEL2_T
BBI_SLOT_4(4), RU_TYPE~4,
CELL_PWRSAVE_ None
Signal Power CELl_DEL_HEALC
BBI_SLOT_4~4,
elete
YPE(2 Cell),
Level Chain
BBI_SLOT_5(5), CHAIN_LEVEL2_T
LOWPWR_RFSHD
Reduced), HK~32,
BBI_SLOT_5~5,
CELl_DEL_HEALC
Cell Type),
BBI_SLOT_INVALI YPE~6,
~5,
CELL_PWRSAVE_ CELL_DEL_UNHE
BBI_SLOT_INVALI
None Enumeration values HK(Cell
D(Invalid Healthy
LOAD_SHARE_TYSlot LOAD_SHARE_TY
CELL_PWRSAVE_ None
LOWPWR_RFSHD( AL~33,
D~65535
Chk),
PE(Load
Number) Share PE~7,
LOWPWR_CELLS
Low Power CELL_DEL_SETUP
CELL_DEL_UNHE
Mode Type), MIMO_MUTUAL_AI
HD~6,
None Interval values Consumption
0~255 _FAIL~34,
Not involved None
AL(Cell UnHealthy),
MIMO_MUTUAL_AI D_TYPE~8,
AUTO_PWROFF_
Mode-RF CELL_DEL_141_D
CELL_DEL_SETUP
D_TYPE(MIMO MULTI_SECTOR_S
ONTIME~7
Shutdown), EL~35,
None Interval values _FAIL(Cell
mutual
0~255 aid),Setup TAR~9,
120ms~0,
Not involved None
CELL_PWRSAVE_ CELL_DEL_ULWID
Fail),
MULTI_SECTOR_S MULTI_SECTOR_C
240ms~1,
LOWPWR_CELLS ESCAN~36,
Downlink Static CELL_DEL_141_D
TAR(Multi sector HAIN~10,
480ms~2,
HD(Low Power CELL_DEL_CELLN
None
Inter-Cell Interval values EL(141
star),
0~11
120ms, Cell
240ms,Del), MUX_NORMAL_TY
Not involved
640ms~3, None
Consumption OACCESSALM~11
Interference CELL_DEL_ULWID
MULTI_SECTOR_C
480ms, 640ms, PE~11,
1024ms~4,
Downlink Static Mode-Cell 2
Coordination ESCAN(UL
HAIN(Multi
1024ms, Wide
sector
2048ms, MUX_DOUBLE_TY
2048ms~5,
Inter-Cell Enumeration values Shutdown),
Freq
chain),Scan10240ms,
Cell PE~12, ms
Downlink Dynamic 5120ms,
AUTO_PWROFF_ 5120ms~6,
Interference
Inter-Cell Del),
MUX_NORMAL_TY
1min, 6min, 12min, INVALID_TYPE~13
10240ms~7,
Downlink Static
Coordination ONTIME(Auto
CELL_DEL_CELLN
PE(MUX normal),
Interference
Inter-Cell Interval values 30min,
1~8
Power 60min
Off On Time 1min~8, 6min~9,
Not involved None
Downlink Dynamic
Coordination OACCESSALM(Cel
MUX_DOUBLE_TY 12min~10,
Interference
Inter-Cell r1(1),
Mode) r2(2),
l No Access
PE(MUX r4(4),
Alarm)
double),
Downlink Static r1~0, r2~1, r4~2,
30min~11,
Coordination
Interference r8(8), r16(16),
INVALID_TYPE(Inv
Inter-Cell Enumeration values r8~3, r16~4, r32~5,
60min~12 None
Downlink Dynamic
Coordination r32(32),
alid Type) r64(64),
Interference r64~6, Infinity~7
Inter-Cell
Downlink Static Infinity(Infinity)
SAME_AS_TRIG_
Coordination
Interference SAME_AS_TRIG_
Inter-Cell Enumeration values QUAN(Same as None
Downlink Dynamic
Coordination QUAN~0, BOTH~1
Interference Trig Quan), BOTH
Inter-Cell
Downlink Static 0ms~0, 40ms~1,
Coordination
Interference 64ms~2,
Inter-Cell Enumeration values RSRP, RSRQ RSRP~0,80ms~3,
RSRQ~1 None
Downlink Dynamic
Coordination 100ms~4,
Interference
Inter-Cell
Downlink Static
Coordination 0ms, 40ms, 64ms, 128ms~5,
Interference
Inter-Cell Interval values 0~30
80ms, 100ms, Not involved
160ms~6, 0.5dB
Downlink Dynamic
Coordination
Interference
Inter-Cell 128ms, 160ms, 256ms~7,
Downlink Static
Coordination 256ms, 320ms, 320ms~8,
Interference
Inter-Cell Enumeration values None
Downlink Dynamic
Coordination 480ms, 512ms, 480ms~9,
Interference
Inter-Cell 640ms, 1024ms, 512ms~10,
Coordination
Interference 1280ms,
Interval values -30~30 2560ms, 640ms~11,
Not involved 0.5dB
Downlink Dynamic
Coordination 5120ms 1024ms~12,
Inter-Cell 1280ms~13,
Low Power
Interference Interval values 0~11 Not involved
2560ms~14, None
Consumption
Coordination Mode 5120ms~15
Low Power
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Consumption Mode
Low Power
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Consumption Mode
Low Power
Composite type 00:00:00~23:59:59 Not involved None
Consumption Mode
Low Power
Composite type 00:00:00~23:59:59 Not involved None
Consumption Mode
Low Power
Interval values 0~1440 Not involved min
Consumption Mode
Low Power
Interval values 0~1440 Not involved min
Consumption Mode
Low Power
Interval values 0~1440 Not involved min
Consumption Mode
Low Power
Interval values 10~100 Not involved %
Consumption Mode
Low Power
Interval values -10~0 Not involved dB
Consumption Mode
Low Power
Interval values 1~1440 Not involved min
Consumption Mode
3GPP R8
Interval values 0~11 Not involved None
Specifications
3GPP R8
Specifications
Interval values 1~15 Not involved None
Admission Control
3GPP R8 Control
Congestion
Specifications
Interval values 1~15 Not involved None
Admission Control
Congestion
3GPP R8 Control
Specifications Interval values 10~99 Not involved %
Admission Control
3GPP R8
Specifications Interval values 10~99 Not involved %
Admission Control
3GPP R8
Specifications Interval values 10~99 Not involved %
Admission Control
3GPP R8
Specifications Interval values 10~99 Not involved %
Admission Control
3GPP R8
Specifications Interval values 0~90 Not involved %
Admission Control
3GPP R8
Specifications Interval values 0~90 Not involved %
Admission Control
3GPP R8
Specifications Interval values 0~90 Not involved %
Admission Control
3GPP R8
Specifications Interval values 0~99 Not involved %
Congestion Control
3GPP R8
Specifications Interval values 0~99 Not involved %
Congestion Control
3GPP R8
Specifications Interval values 0~99 Not involved %
Congestion Control
3GPP R8
Specifications Interval values 0~99 Not involved %
Congestion Control
3GPP R8
Specifications Interval values 1~100 Not involved %
Congestion Control
3GPP R8
Specifications Interval values 1~100 Not involved %
Congestion Control
3GPP R8
Specifications Interval values 1~100 Not involved %
Congestion Control
3GPP R8
Specifications Interval values 0~100 Not involved %
Admission Control
3GPP R8
Specifications Interval values 0~100 Not involved %
Admission Control
3GPP R8
Specifications Interval values 1~15 Not involved None
Congestion Control
3GPP R8
Specifications Interval values 0~50 Not involved %
3GPP R8 Control
Congestion
Specifications
Radio/transport Interval values 1~15 Not involved None
Resource
3GPP R8 Pre-
emption
Specifications
Interval values 10~100 Not involved %
Admission Control
3GPP R8 Control
Congestion
Specifications
Interval values 10~100 Not involved %
Admission Control
3GPP R8 Control
Congestion
Specifications
Interval values 10~100 Not involved %
Admission Control
3GPP R8 Control
Congestion
Specifications
Interval values 10~100 Not involved %
Admission Control
Congestion
3GPP R8 Control
Specifications Interval values 0~9000 Not involved None
Admission Control
RF Channel
Intelligent Interval values 0~11 Not involved None
Shutdown
RF Channel
Intelligent Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Shutdown
RF Channel
Intelligent Composite type 00:00:00~23:59:59 Not involved None
Shutdown
RF Channel
Intelligent Composite type 00:00:00~23:59:59 Not involved None
Shutdown
RF Channel
Intelligent Interval values 0~7 Not involved dB
Shutdown
Intelligent Power-
Off of Carriers in Interval values 0~11 Not involved None
the Same Coverage
Intelligent Power-
Off of Carriers in Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
the Same Coverage
Intelligent Power-
Off of Carriers in Composite type 00:00:00~23:59:59 Not involved None
the Same Coverage
Intelligent Power-
Off of Carriers in Composite type 00:00:00~23:59:59 Not involved None
the Same Coverage
Intelligent Power-
Off of Carriers in Interval values 0~100 Not involved %
the Same Coverage
Intelligent Power-
Off of Carriers in Interval values 0~100 Not involved %
the Same Coverage
Intelligent Power-
Off of Carriers in Interval values 0~100 Not involved %
the Same Coverage
Intelligent Power-
Off of Carriers in Interval values 0~100 120ms~0,
Not involved %
the Same Coverage 240ms~1,
480ms~2,
Uplink
None Static Inter- Interval values 0~11 Not involved None
120ms, 240ms, 640ms~3,
Cell Interference
480ms, 640ms, 1024ms~4,
Coordination
Uplink 1024ms, 2048ms, 2048ms~5,
Uplink Static Inter-
Dynamic Enumeration values ms
Cell Interference 5120ms, 10240ms, 5120ms~6,
Inter-Cell
Coordination 1min, 6min, 12min, 10240ms~7,
Interference
Uplink Dynamic Interval values 30min,
1~8 60min 1min~8, 6min~9,
Not involved None
Coordination
Inter-Cell 12min~10,
Interference 30min~11,
Coordination 60min~12
Uplink Static Inter-
Cell Interference
r1(1), r2(2), r4(4),
Coordination r1~0, r2~1, r4~2,
Uplink r8(8), r16(16),
Uplink Static
DynamicInter- Enumeration values r8~3, r16~4, r32~5, None
Cell Interference r32(32), r64(64),
Inter-Cell r64~6, Infinity~7
Coordination Infinity(Infinity)
SAME_AS_TRIG_
Interference
Uplink Static Inter- SAME_AS_TRIG_
Uplink Dynamic
Coordination Enumeration values QUAN(Same as None
Cell Interference QUAN~0, BOTH~1
Inter-Cell Trig Quan), BOTH
Coordination 0ms~0, 40ms~1,
Interference
Uplink Static Inter-
Uplink Dynamic Enumeration values RSRP, RSRQ 64ms~2,
RSRP~0,80ms~3,
RSRQ~1 None
Coordination
Cell Interference
Inter-Cell 100ms~4,
Coordination
Interference 0ms, 40ms, 64ms, 128ms~5,
Uplink
Uplink Static
DynamicInter- Interval values
0~30 100ms, Not involved 0.5dB
Coordination 80ms, 160ms~6,
Cell Interference
Inter-Cell 128ms, 160ms, 256ms~7,
Coordination
Interference
Uplink Static Inter- 256ms, 320ms, 320ms~8,
Uplink Dynamic
Coordination Enumeration values ms
Cell Interference 480ms, 512ms, 480ms~9,
Inter-Cell
Coordination 640ms, 1024ms, 512ms~10,
Interference
Uplink Dynamic Interval values 1280ms,
-30~30 2560ms, 640ms~11,
Not involved 0.5dB
Coordination
Inter-Cell 5120ms 1024ms~12,
ULSCH_STRATEG
Interference 1280ms~13,
ULSCH_STRATEG
None Interval values Y_EPF(EPF),
0~11 Not involved None
Coordination 2560ms~14,
Y_EPF~0,
ULSCH_STRATEG
5120ms~15
ULSCH_STRATEG
Basic Scheduling Y_MAX_CI(MAX_C
Y_MAX_CI~1,
Enhanced Enumeration values ADAPTIVE_HARQ_
I), ADAPTIVE_HARQ_ None
SW_ON(On), ULSCH_STRATEG
Scheduling ULSCH_STRATEG SW_ON~0,
ADAPTIVE_HARQ_ Y_PF~2,
UL Synchronization Y_PF(PF), ADAPTIVE_HARQ_
Enumeration values SW_OFF(Off), ULSCH_STRATEG None
HARQ ULSCH_STRATEG SW_OFF~1,
ADAPTIVE_HARQ_ Y_RR~3
Y_RR(RR) ADAPTIVE_HARQ_
SW_SEMI_ON(Se
AMC Interval values 1~99 SW_SEMI_ON~2
Not involved 0.01
miOn)

Dynamic
Interval values 0~100 Not involved %
Scheduling
Dynamic
Interval values 1~10 Not involved ms
Scheduling
HOPPING_OFF(Ho
Dynamic pping off), HOPPING_OFF~0,
Interval values 45~1500 Not involved byte
Scheduling HOPPING_TYPE1( HOPPING_TYPE1~
Basic Scheduling Hopping Type 1), 1,
Enhanced Enumeration values HOPPING_TYPE2( HOPPING_TYPE2~ None
Scheduling
Dynamic Hopping Type 2), 2,
Scheduling HOPPING_TYPE2_ HOPPING_TYPE2_
Interval values 0~100
RANDOM(Hopping Not involved
RANDOM~3 %
Admission Control RachAdjSwitch(Rac
Congestion Control Type 2 Random)
hAdjSwitch),
None Interval values 0~11
HoRaSwitch(HoRa Not involved None
RachAdjSwitch~0,
3GPP R8 Switch),
HoRaSwitch~1,
Specifications UnsyncRaSwitch(U
Bit field type UnsyncRaSwitch~2 None
Random Access nsyncRaSwitch),
, MaksIdxSwitch~3,
Procedure MaksIdxSwitch(Mak
SrsSubframeRecfS
3GPP R8 BackOffSwitch~4
SrsSubframeRecfS
Bit field type sIdxSwitch),
witch(SrsSubframe None
Specifications BackOffSwitch(Bac witch~0
RecfSwitch)
3GPP R8 kOffSwitch)
PucchSwitch(Pucch
Bit field type PucchSwitch~0 None
Specifications Switch)
Active Queue
Management Bit field type AqmAlgoSwitch AqmAlgoSwitch~0 None
(AQM)
UL 2x2 MU-MIMO
CqiAdjAlgoSwitch~
CQI Adjustment CqiAdjAlgoSwitch,
Bit field type 0, None
Dynamic StepVarySwitch
StepVarySwitch~1
Scheduling
None Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
DynAdjVoltSwitch(D
Adaptive Power DynAdjVoltSwitch~
Bit field type ynamic Adjust None
Consumption 0
Voltage Switch)
LCEM_RAC_ALG_
TCH(dlCacPredictS
DL_PREDICT_SWI
witch),
TCH~2,
LCEM_RAC_ALG_
LCEM_RAC_ALG_
UL_PREDICT_SWI
IntraFreqActiveMlb UL_PREDICT_SWI
TCH(ulCacPredictS
Switch(IntraFreqAct
3GPP R8 TCH~3,
witch),
iveMlbSwitch),
Specifications LCEM_RAC_ALG_
LCEM_RAC_ALG_
InterFreqMlbSwitch( IntraFreqActiveMlb
Admission
3GPP R8 Control GBR_USAGE_SWI
GBR_USAGE_SWI
InterFreqMlbSwitch) Switch~0,
Congestion
SpecificationsControl Bit field type TCH~4, None
Radio/transport ,TCH(GbrUsedPRb InterFreqMlbSwitch
LCEM_RAC_ALG_
Intra-LTE Load CheckSwitch),
Resource UtranMlbSwitch(Utr ~1,
Balancing Pre- LCEM_RAC_ALG_
DL_LDC_SWITCH~
Physical Channel
emption Load Bit field type anMlbSwitch), UtranMlbSwitch~2,
5, None
Inter-RAT DL_LDC_SWITCH(
CloseLoopSpsSwitc PdschSpsPcSwitch
CloseLoopSpsSwitc
Management GeranMlbSwitch(G
PdschSpsPcSwitch, GeranMlbSwitch~3,
LCEM_RAC_ALG_
Sharing to UTRAN dlLdcSwitch),
h, ~0,
h~0,
Broadcast of eranMlbSwitch),
PhichInnerLoopPcS CdmaMlbSwitch~4,
UL_LDC_SWITCH~
Inter-RAT Load Bit field type LCEM_RAC_ALG_
InnerLoopPuschSwi PhichInnerLoopPcS
InnerLoopPuschSwi None
system information CdmaMlbSwitch(Cd
witch, IntraFreqIdleMlbSwi
6,
Sharing
Broadcast to GERAN
of UL_LDC_SWITCH(
tch, witch~1,
tch~1,
Dynamic Downlink maMlbSwitch),
PdcchPcSwitch tch~5
LCEM_LDC_ALG_
system information ulLdcSwitch),
PhSinrTarUpdateS
IntraFreqIdleMlbSwi PdcchPcSwitch~2
PhSinrTarUpdateS
Power Allocation Bit field type REL_DRB_SWITC None
Uplink Power LCEM_LDC_ALG_
witch,
tch(IntraFreqIdleMlb witch~2,
Single H~7,
ControlStreaming REL_DRB_SWITC
InnerLoopPucchSwi
Switch) InnerLoopPucchSwi
Beamforming SpsSchSwitch(Sps LCEM_RAC_ALG_
Bit field type H(LdcDrbRelSwitch
tch,
BfSwitch tch~3,
BfSwitch~0 None
Dual streaming SchSwitch), PREEMPTION_SW
),
OiSinrTarUpdateSw
FreqSelSwitch(Freq OiSinrTarUpdateSw
Beamforming
Basic Scheduling SinrAdjustSwitch(Si ITCH~8
LCEM_RAC_ALG_
itch
SelSwitch), itch~4
FreqSelSwitch~0,
Basic Scheduling
Enhanced Bit field type nrAdjustSwitch),
PREEMPTION_SW SpsSchSwitch~0, None
Enhanced ServiceDiffSwitch(S
PreAllocationSwitch ServiceDiffSwitch~1
SinrAdjustSwitch~1,
Scheduling ITCH(PreemptionS
Scheduling erviceDiffSwitch)
(PreAllocationSwitc PreAllocationSwitch
witch)
TTI Bundling Bit field type h), ~2, None
VoIP Semi-
3GPP R8 UlVmimoSwitch(UlV UlVmimoSwitch~3,
persistent
Specifications mimoSwitch), TtiBundlingSwitch~
SchedulingControl Enumeration values FreqPriorIFHOSwitc
Admission
OFF(Off), ON(On)
TtiBundlingSwitch(T OFF~0, ON~1
4, Im2IcSwitch~5 None
Basic Scheduling h(FreqPriorIFHOSw
tiBundlingSwitch), FreqPriorIFHOSwitc
Intra-LTE Load itch),
Im2IcSwitch(Im2IcS h~0,
Bit field type None
Balancing FreqPriorIFBlindHO
witch) FreqPriorIFBlindHO
Downlink Static Switch(FreqPriorIF
MODE1(DL band Switch~1
None
Inter-Cell Interval values BlindHOSwitch)
0~11 scheme
division Not involved None
Interference No.1), MODE2(DL
MODE1~0,
Coordination band division
Enumeration values MODE2~1, None
Downlink Dynamic scheme No.2),
MODE3~2
Inter-Cell MODE3(DL band
Dynamic Downlink
Interference division
Interval values 0~11 scheme Not involved None
Power Allocation
Coordination No.3)
Dynamic Downlink
Interval values -150~150 Not involved 0.1dB
Power Allocation
Dynamic Downlink PA_NEG6(-6),
Interval values 0~11
PA_NEG4DOT77(- Not involved
PA_NEG6~0, None
Power Allocation
4.77), PA_NEG3(- PA_NEG4DOT77~1
Dynamic Downlink PA_NEG6(-6),
3), , PA_NEG3~2,
Enumeration values PA_NEG4DOT77(- PA_NEG6~0, None
Power Allocation PA_NEG1DOT77(- PA_NEG1DOT77~3
4.77),
1.77), PA_NEG3(-
PA_0(0), PA_NEG4DOT77~1
, PA_0~4, PA_1~5,
Dynamic Downlink 3),
PA_1(1), PA_2(2), ,PA_2~6,
PA_NEG3~2,
PA_3~7
Enumeration values None
Power Allocation PA_NEG1DOT77(-
PA_3(3) PA_NEG1DOT77~3
1.77), PA_0(0), , PA_0~4, PA_1~5,
Dynamic Downlink PA_1(1), PA_2(2), PA_2~6, PA_3~7
Interval values 0~11 Not involved None
Power Allocation PA_3(3)
Dynamic Downlink
Interval values -150~150 Not involved 0.1dBm
Power Allocation
DLSCH_PRI_TYPE DLSCH_PRI_TYPE
None Interval values 0~11
_EPF(EPF), Not involved
_EPF~0, None
DLSCH_PRI_TYPE DLSCH_PRI_TYPE
Basic Scheduling
_PF(PF), _PF~1,
Enhanced Enumeration values None
DLSCH_PRI_TYPE DLSCH_PRI_TYPE
Scheduling
Dynamic _MAX_CI(MAX C/I), _MAX_CI~2,
Scheduling DLSCH_PRI_TYPE DLSCH_PRI_TYPE
Interval values 0~100 Not involved %
Admission Control _RR(RR) _RR~3
Dynamic
Congestion Control
Scheduling
Interval values 0~100 Not involved 0.01
Admission Control
Dynamic
Congestion Control
Scheduling
Interval values 0~100 Not involved 0.01
Admission Control
Congestion Control
None Interval values 0~11 Not involved None
3GPP R8
Specifications
Interval values 1~100 Not involved %
Intra-LTE Load
3GPP R8
Balancing
Specifications
3GPP R8 Load Interval values 1~100 Not involved %
Intra-LTE
Specifications
Balancing LOAD_EXCHANGE
3GPP R8 Load
Inter-RAT LOAD_EXCHANGE
Interval values _PERIOD_1S(1s),
1~100 Not involved %
Specifications
Sharing to UTRAN _PERIOD_1S~0,
LOAD_EXCHANGE
Intra-LTE
Inter-RAT Load LOAD_EXCHANGE
3GPP R8 Load
Balancing
_PERIOD_2S(2s),
_PERIOD_2S~1,
Sharing to GERAN
Specifications Enumeration values LOAD_EXCHANGE s
Inter-RAT Load LOAD_EXCHANGE
Intra-LTE Load _PERIOD_5S(5s),
Sharing
3GPP R8to UTRAN _PERIOD_5S~2,
Balancing LOAD_EXCHANGE
Inter-RAT Load
Specifications Interval values 1~50 LOAD_EXCHANGE
Not involved %
Inter-RAT Load _PERIOD_10S(10s
Sharing
Intra-LTEto GERAN _PERIOD_10S~3
Sharing toLoad
UTRAN )
Balancing
Inter-RAT Load Interval values 1~50 Not involved %
Inter-RAT
Sharing toLoad
GERAN
Sharing to UTRAN
Inter-RAT
None Load Interval values 0~11 Not involved None
Sharing to GERAN
3GPP R8
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Specifications
3GPP R8
Interval values 1~4 Not involved None
Specifications
3GPP R8
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Specifications

None Interval values 0~11 Not involved None

None Interval values 0~50 Not involved None

Sleeping Cell
Interval values 0~11 Not involved None
Detection
Sleeping Cell
Composite type 00:00:00~23:59:59 Not involved None
Detection
Sleeping Cell
Composite type 00:00:00~23:59:59 Not involved None
Detection
Sleeping Cell
Interval values 0~72 Not involved h
Detection
MODE1(UL band
Uplink
None Static Inter- Interval values 0~11 scheme Not involved None
division
Cell Interference
No.1), MODE2(UL
Coordination MODE1~1,
band division
Uplink Dynamic Enumeration values MODE2~2, None
scheme No.2),
Inter-Cell MODE3~3
MODE3(UL band
Interference
None Interval values division
0~11 scheme Not involved None
Coordination
No.3)

None Interval values 0~9 Not involved None


TM1(TM1),
TM2(TM2), TM1~0, TM2~1,
None Enumeration values None
TM7(TM7), TM7~6, TM8~7
TM8(TM8)
None Interval values 0~100 Not involved None
None Interval values 0~100 Not involved None

None Interval values 0~10000 Not involved 0.01mw

None Interval values 0~10000 Not involved 0.01mw

None Interval values 0~1200 Not involved None

None Interval values 0~1200 Not involved None

3GPP R8 MOD_PERIOD_CO MOD_PERIOD_CO


Interval values 0~11
EFF_N2(2), Not involved
EFF_N2~0, None
Specifications
MOD_PERIOD_CO MOD_PERIOD_CO
Broadcast of EFF_N4(4), EFF_N4~1,
Enumeration values None
system information MOD_PERIOD_CO MOD_PERIOD_CO
EFF_N8(8), EFF_N8~2,
None
Physical Channel Interval values MOD_PERIOD_CO
0~11 MOD_PERIOD_CO
Not involved None
Management EFF_N16(16) EFF_N16~3
Broadcast of
Physical Channel Interval values -3175~3175 Not involved 0.005dB
system information
Management
Dynamic Downlink
Broadcast
Power of
Allocation
Physical Channel Interval values -3175~3175 Not involved 0.005dB
system information
Management
Dynamic Downlink
Broadcast
Power of
Allocation
Physical Channel Interval values -3175~3175 Not involved 0.005dB
system information
Management
Dynamic Downlink
Broadcast
Physical of
Channel
Power Allocation Interval values -3175~3175 Not involved 0.005dB
system information
Management
Dynamic
BroadcastDownlink
of
Physical Channel
Power
systemAllocation
information
Management Interval values -3175~3175 Not involved 0.005dB
Paging
Broadcast of
Dynamicinformation
system Downlink
Power Allocation Interval values -3175~3175 Not involved 0.005dB
Random Access
Procedure
Dynamic
None Downlink Interval values -3175~3175 Not involved 0.005dB
Power Allocation

None
Physical Channel Interval values 0~11
DBM_120(- Not involved None
Management 120dBm),
Broadcast of DBM_118(-
Physical Channel Interval values -600~500 Not involved 0.1dBm
system information 118dBm),
Management
Dynamic Downlink DBM_116(-
Broadcast of
Power Allocation Interval values 0~3
116dBm), Not involved None
system information DBM_120~0,
DBM_114(-
Dynamic Downlink DB0_PWR_RAMPI DBM_118~1,
DB0_PWR_RAMPI
3GPP 114dBm),
Power R8
Allocation Interval values 0~11
NG_STEP(0dB), DBM_116~2,
Not involved
NG_STEP~0, None
Specifications DBM_112(-
3GPP R8 DB2_PWR_RAMPI DBM_114~3,
DB2_PWR_RAMPI
112dBm),
Specifications NG_STEP(2dB), DBM_112~4,
NG_STEP~1,
Enumeration values DBM_110(- DBM_110~5, dB
Transport Channel DB4_PWR_RAMPI
110dBm), DB4_PWR_RAMPI
3GPP R8
Management NG_STEP(4dB), DBM_108~6,
NG_STEP~2,
DBM_108(-
Specifications DB6_PWR_RAMPI DBM_106~7,
DB6_PWR_RAMPI
Enumeration values 108dBm), dBm
Transport Channel NG_STEP(6dB)
SC0(0), SC1(1), DBM_104~8,
NG_STEP~3
SC0~0, SC1~1,
DBM_106(-
Management SC2(2), SC3(3), DBM_102~9,
SC2~2, SC3~3,
3GPP R8 106dBm),
Interval values 0~11
SC4(4), SC5(5), DBM_100~10,
Not involved
SC4~4, SC5~5, None
Specifications DBM_104(-
3GPP R8 SC6(6), SC7(7), DBM_98~11,
SC6~6, SC7~7,
104dBm),
Specifications SC8(8), SC9(9), DBM_96~12,
SC8~8, SC9~9,
Enumeration values DBM_102(- None
Physical Channel SC10(10), DBM_94~13,
SC10~10,
102dBm),
Management SC11(11), DBM_92~14,
SC11~11,
DBM_100(-
SC12(12), DBM_90~15
SC12~12,
100dBm),
SC13(13),
DBM_98(-98dBm), SC13~13,
SC14(14)
DBM_96(-96dBm), SC14~14
DBM_94(-94dBm),
DBM_92(-92dBm),
DBM_90(-90dBm)
3GPP R8 BOOLEAN_FALSE( BOOLEAN_FALSE
Specifications False), ~0,
Enumeration values None
Physical Channel BOOLEAN_TRUE( BOOLEAN_TRUE~
Management True) 1
None Interval values 0~11 Not involved None
Physical Channel
Management NORMAL, NORMAL~0,
Enumeration values None
Broadcast of EXTENDED EXTENDED~1
Physical Channel
system information ONE_SIXTH~0,
Management ONE_SIXTH, HALF,
Enumeration values HALF~1, ONE~2, None
Broadcast of ONE, TWO
TWO~3
system information
None Interval values 0~11
rf32(32 radio Not involved None
Logical Channel
frames), rf64(64 FOURT~0,
Management FOURT, TWOT,
radio frames), rf32~0,
TWOT~1, rf64~1,
ONET~2, None
Broadcast of Enumeration values ONET, HALFT,
rf128(128 radio rf128~2,
HALFT~3, rf256~3
system information QUARTERT,
Broadcast of frames), rf256(256 QUARTERT~4,
Paging ONE_EIGHTT,
system information Enumeration values radio frames) ONE_EIGHTT~5, None
ONE_SIXTEENTHT
Paging ONE_SIXTEENTHT
,
~6,
None Interval values ONE_THIRTY_SEC
0~11 Not involved None
ONE_THIRTY_SEC
Physical Channel ONDT
ONDT~7
Management
Interval values 1~4 Not involved None
Broadcast of INTER_SUB_FRA
Physical Channel
system information INTER_SUB_FRA
ME(Inter),
Management ME~0,
Enumeration values INTRA_AND_INTE None
Broadcast of INTRA_AND_INTE
Physical Channel R_SUB_FRAME(Int
system information R_SUB_FRAME~1
Management er And Intra)
Interval values 0~98 Not involved RB
Broadcast of
Physical Channel
system information BOOLEAN_FALSE( BOOLEAN_FALSE
Management False), ~0,
Enumeration values None
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
Physical Channel
system information True) 1
Management
Interval values 0~29 Not involved None
Broadcast of
Physical Channel
system information BOOLEAN_FALSE( BOOLEAN_FALSE
Management False), ~0,
Enumeration values None
Broadcast of BOOLEAN_TRUE( BOOLEAN_TRUE~
Physical Channel
system information True) 1
Management
Interval values 0~7 Not involved None
Broadcast of
system information BOOLEAN_FALSE( BOOLEAN_FALSE
False), ~0,
UL 64QAM Enumeration values None
BOOLEAN_TRUE( BOOLEAN_TRUE~
True) 1
3GPP R8
Interval values 0~11 Not involved None
Specifications
3GPP R8 DS2_DELTA_SHIF DS2_DELTA_SHIF
Specifications T(ds2), T~1,
Enumeration values None
Physical Channel DS3_DELTA_SHIF DS3_DELTA_SHIF
RAN Sharing with
Management T(ds3) T~2
Common Carrier
Character string 6~16 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 2~3 characters Not involved None
RAN Sharing with
Dedicated Carrier
None Interval values 0~11 Not involved None
PS Inter-RAT
Mobility between E-
Character string 6~16 characters Not involved None
UTRAN and
CDMA2000
PS Inter-RAT
PERMIT_HO_ENU PERMIT_HO_ENU
Mobility between E-
M(Permit Ho), M~0,
UTRAN and Enumeration values None
LOFD- FORBID_HO_ENU FORBID_HO_ENU
CDMA2000 PERMIT_RMV_EN PERMIT_RMV_EN
002001:Automatic M(Forbid Ho) M~1
Inter-RAT ANR UM(Permit Rmv), UM~0,
Neighbour Relation Enumeration values None
FORBID_RMV_EN FORBID_RMV_EN
(ANR)
UM(Forbid Rmv) UM~1
Inter-RAT
Mobility ANR
Interval values 0~32 Not involved None
Management
Automatic BOOLEAN_FALSE( BOOLEAN_FALSE
PS Inter-RAT
Neighbour Relation False), ~0,
Mobility Enumeration values None
(ANR) between E- BOOLEAN_TRUE( BOOLEAN_TRUE~
UTRAN
Inter-RATand
ANR True) 1
PS Inter-RAT
CDMA2000
Mobility between E- Character string 0~99 characters Not involved None
Automatic
UTRAN
NeighbourandRelation
CDMA2000
(ANR) Character string 0~99 characters Not involved None
Automatic
Inter-RAT ANR
Neighbour Relation bc0~0, bc1~1,
PS Inter-RAT
(ANR)
None Interval values 0~11 bc2~2, bc3~3,
bc0, bc1, bc2, bc3, Not involved None
Mobility
Inter-RATbetween
ANR E- bc4~4, bc5~5,
bc4, bc5, bc6, bc7,
UTRAN and bc6~6, bc7~7,
PS Inter-RAT bc8, bc9, bc10,
CDMA2000 Enumeration values bc8~8, bc9~9, None
Mobility between bc11, bc12, bc13,
Cell Selection andE- bc10~10, bc11~11,
UTRAN and bc14, bc15, bc16,
Reselection bc12~12, bc13~13,
CDMA2000 Interval values bc17
0~2047 Not involved
Inter-RAT
PS ANR bc14~14, bc15~15, None
CellInter-RAT
Selection and bc16~16, bc17~17
Mobility between E-
Reselection
UTRAN
3GPP R8
Inter-RATand
ANR Interval values -15~15 Not involved dB
CDMA2000
Specifications
Inter-RAT ANR NOT_CFG(Not
PS Inter-RAT NOT_CFG~0,
3GPP R8 Enumeration values configure), None
Mobility between E- CFG~1
Specifications CFG(Configure)
UTRAN and
PS Inter-RAT
CDMA2000 Interval values 0~15 Not involved None
Mobility between E-
RAN
UTRAN Sharing
and with
Common
CDMA2000 Carrier
Character string 3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 2~3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Interval values 0~1048575 Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Interval values 0~255 Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 2~3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Interval values 0~65535 Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Interval values 1~65533,65535 Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 2~3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 3 characters Not involved None
RAN Sharing with
Dedicated Carrier
RAN Sharing with
Common Carrier
Character string 2~3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Interval values 0~268435455 Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 2~3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common Carrier
Character string 2~3 characters Not involved None
RAN Sharing with
PS Inter-RAT
Dedicated Carrier bc0~0, bc1~1,
Mobility
PS between E-
Inter-RAT bc2~2, bc3~3,
Character string 6~16 characters
bc0, bc1, bc2, bc3, Not involved None
UTRAN between
Mobility and E- bc4~4, bc5~5,
CDMA2000 bc4, bc5, bc6, bc7,
UTRAN and bc6~6, bc7~7,
PS Inter-RAT bc8, bc9, bc10,
CDMA2000 Enumeration values bc8~8, bc9~9, None
Mobility between bc11, bc12, bc13,
Cell Selection andE- bc10~10, bc11~11,
UTRAN
3GPP R8and bc14, bc15, bc16,
Reselection bc12~12, bc13~13,
CDMA2000 Interval values bc17
0~2047 Not involved
Specifications
Inter-RAT ANR bc14~14, bc15~15, None
CellInter-RAT
PS Selection and bc16~16, bc17~17
Reselection
Mobility between E-
PS Inter-RAT
Inter-RAT ANR Interval values 0~511
CDMA2000_HRPD( Not involved None
UTRAN and
Mobility
CDMA2000 between E- CDMA2000_HRPD) CDMA2000_HRPD
UTRAN and and
Cell Selection , ~0,
Enumeration values None
CDMA2000
Reselection CDMA2000_1XRTT CDMA2000_1XRTT
RAN Sharing with
Cell Selection and (CDMA2000_1XRT ~1
Common
ReselectionCarrier T)
Character string 3 characters Not involved None
RAN Sharing with
RAN Sharing
Dedicated with
Carrier
Common
PS Carrier
Inter-RAT Character string 2~3 characters Not involved None
RAN Sharing
Mobility withE-
between
Dedicated
UTRAN and Carrier
CDMA2000 Character string 0~99 characters Not involved None
Cell Selection and
Reselection
None
Inter-RAT ANR Interval values 0~11 Not involved None
PS Inter-RAT
Mobility between E-
Character string 6~16 characters Not involved None
UTRAN and
PS Inter-RAT
CDMA2000 PERMIT_HO_ENU PERMIT_HO_ENU
Mobility between E-
M(Permit Ho), M~0,
UTRAN and Enumeration values None
FORBID_HO_ENU FORBID_HO_ENU
CDMA2000
Automatic PERMIT_RMV_EN PERMIT_RMV_EN
M(Forbid Ho) M~1
Inter-RAT ANR
Neighbour Relation UM(Permit Rmv), UM~0,
Enumeration values None
(ANR) FORBID_RMV_EN FORBID_RMV_EN
Inter-RAT ANR UM(Forbid Rmv) UM~1
Mobility
Interval values 0~32 Not involved None
Management
Automatic BOOLEAN_FALSE( BOOLEAN_FALSE
Neighbour Relation False), ~0,
Enumeration values None
(ANR)
PS Inter-RAT BOOLEAN_TRUE( BOOLEAN_TRUE~
Inter-RAT
Mobility ANR E-
between True) 1
UTRAN and Character string 0~99 characters Not involved None
PS Inter-RAT
CDMA2000
Mobility
Inter-RATbetween
ANR E-
UTRAN and Character string 0~99 characters Not involved None
CDMA2000
Inter-RAT ANR
None Interval values 0~11 Not involved None
bc0~0, bc1~1,
PS Inter-RAT bc2~2, bc3~3,
bc0, bc1, bc2, bc3,
Mobility between E- bc4~4, bc5~5,
bc4, bc5, bc6, bc7,
UTRAN and bc6~6, bc7~7,
bc8, bc9, bc10,
CDMA2000
PS Inter-RAT Enumeration values bc8~8, bc9~9, None
bc11, bc12, bc13,
Cell Selection
Mobility andE-
between bc10~10, bc11~11,
bc14, bc15, bc16,
Reselection
UTRAN and bc12~12, bc13~13,
Interval values bc17
0~7 Not involved
Inter-RAT ANR
CDMA2000 bc14~14, bc15~15, None
Cell Selection and bc16~16, bc17~17
Cell Selection and
Reselection Interval values 0~63 Not involved dB
Reselection
Cell Selection and
Interval values 0~63 Not involved dB
Reselection
PS Inter-RAT
Mobility between E-
Character string 3 characters Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
Character string 2~3 characters Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
Interval values 0~65535 Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
Interval values 1~65533,65535 Not involved None
UTRAN and
PS Inter-RAT
GERAN NOT_CFG(Not
Mobility between E- NOT_CFG~0,
Enumeration values configure), None
UTRAN and CFG~1
PS Inter-RAT CFG(Configure)
GERAN
Mobility between E-
Interval values 0~255 Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E- GSM_dcs1800, GSM_dcs1800~0,
Enumeration values None
UTRAN and GSM_pcs1900 GSM_pcs1900~1
PS Inter-RAT
GERAN
Mobility between E-
Interval values 0~1023 Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
Interval values 0~7 Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
PS Inter-RAT Interval values 0~7 Not involved None
UTRAN and
Mobility between E-
GERAN and DTM_AVAILABLE~
UTRAN DTM_AVAILABLE,
0,
GERAN Enumeration values DTM_NOT_AVAILA None
DTM_NOT_AVAILA
Service
PS based inter-
Inter-RAT BLE
BLE~1
RAT handover
Mobility to E-
between
GERAN and Character string 0~99 characters Not involved None
UTRAN
GERAN
None Interval values 0~11 Not involved None
PS Inter-RAT
Mobility between E-
Character string 3 characters Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
Character string 2~3 characters Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
Interval values 1~65533,65535 Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
Interval values 0~65535 Not involved None
UTRAN and
Automatic
GERAN PERMIT_RMV_EN PERMIT_RMV_EN
Neighbour Relation UM(Permit Rmv), UM~0,
Enumeration values None
(ANR) FORBID_RMV_EN FORBID_RMV_EN
Inter-RAT ANR PERMIT_HO_ENU
UM(Forbid Rmv) PERMIT_HO_ENU
UM~1
M(Permit Ho), M~0,
Inter-RAT ANR Enumeration values None
FORBID_HO_ENU FORBID_HO_ENU
M(Forbid Ho) M~1
Mobility
Interval values 0~32 Not involved None
Management
Automatic BOOLEAN_FALSE( BOOLEAN_FALSE
Neighbour Relation False), ~0,
Enumeration values None
(ANR) BOOLEAN_TRUE( BOOLEAN_TRUE~
PS Inter-RAT
Inter-RAT ANR True) 1
Mobility between E-
Character string 0~99 characters Not involved None
UTRAN and
PS Inter-RAT
GERAN
Mobility between E-
Character string 0~99 characters Not involved None
UTRAN and
GERAN
None Interval values 0~11 Not involved None
PS Inter-RAT
Mobility between E-
UTRAN and Interval values 0~31 Not involved None
GERAN
PS Inter-RAT
Inter-RAT ANR E-
Mobility between GSM, GPRS, GSM~0, GPRS~1,
PS Inter-RAT Enumeration values None
UTRAN and EDGE EDGE~2
Mobility
GERAN between E-
UTRAN and
Interval values 0~1023 Not involved None
GERAN
PS
CellInter-RAT
Selection and
Mobility between E-
Reselection GSM_dcs1800, GSM_dcs1800~0,
Enumeration values None
UTRAN and GSM_pcs1900 GSM_pcs1900~1
GERAN NOT_CFG(Not
Cell Selection and NOT_CFG~0,
Enumeration values configure), None
Reselection CFG~1
CFG(Configure)
Cell Selection and
Interval values 0~7 Not involved None
Reselection
NOT_CFG(Not
Cell Selection and NOT_CFG~0,
Enumeration values configure), None
Reselection CFG~1
CFG(Configure)
Cell Selection and
Interval values 0~39 Not involved dBm
Reselection
Cell Selection and
Interval values 0~45 Not involved dBm
Reselection
Cell Selection and
Interval values 0~31 Not involved 2dB
Reselection
Cell Selection and
Interval values 0~31 Not involved 2dB
Reselection
PS Inter-RAT
Mobility between E-
UTRAN and Interval values -15~15 Not involved dB
GERAN
Inter-RAT
Cell ANRand
Selection
Interval values 0~255 Not involved None
Reselection

None
Broadcast of Interval values 0~11 Not involved None
system information
PS Inter-RAT
Broadcast of Interval values 0~31 Not involved None
Mobility between E-
system
UTRAN andinformation
PS Inter-RAT
GERAN Interval values 0~1023 Not involved None
Mobility between E-
UTRAN and
GERAN
None Interval values 0~11 Not involved None
Cell Selection and
Re-selection
Coverage Based Interval values 0~503 Not involved None
Intra-frequency
Handover
None Interval values dB-24(-24dB),
0~11 dB- Not involved None
22(-22dB), dB-20(-
Coverage Based 20dB), dB-18(-
Intra-frequency Character string dB-24(-24dB),
dB-16(-dB-
3 characters
18dB), Not involved None
Handover 22(-22dB), dB-20(-
16dB), dB-14(-
Coverage Based 20dB), dB-18(-
14dB), dB-12(-
Intra-frequency Character string 2~3 characters
18dB), Not involved None
12dB), dB-16(-
dB-10(- dB-24~0, dB-22~1,
Handover 16dB),
Coverage Based 10dB), dB-14(-
dB-8(-8dB), dB-20~2, dB-18~3,
14dB), dB-12(-
dB-6(-6dB),
Intra-frequency Interval values 0~1048575 dB-5(- dB-16~4, dB-14~5,
Not involved None
12dB), dB-10(-
5dB), dB-4(-4dB), dB-24~0,
dB-12~6, dB-22~1,
dB-10~7,
Handover
Coverage Based 10dB), dB-8(-8dB),
dB-3(-3dB), dB-2(- dB-20~2, dB-18~3,
dB-8~8, dB-6~9,
Intra-frequency Interval values dB-6(-6dB),
0~255 dB-5(-
2dB), dB-1(-1dB), dB-16~4,
dB-5~10, dB-14~5,
Not involved
dB-4~11, None
Coverage
Handover Based 5dB), dB-4(-4dB), dB-12~6,
dB0(0dB), dB-3~12, dB-10~7,
dB-2~13,
Intra-frequency dB-3(-3dB),
dB1(1dB), dB-2(- dB-8~8,
dB-1~14,dB-6~9,
dB0~15,
Handover Enumeration values 2dB), dB-1(-1dB), dB-5~10, dB-4~11, dB
dB2(2dB), dB1~16, dB2~17,
Mobility Robust dB0(0dB), dB-3~12, dB-2~13,
dB3(3dB), dB3~18, dB4~19,
Optimization
Cell Selection and dB1(1dB), dB-1~14, dB0~15,
Enumeration values dB4(4dB), dB5~20, dB6~21, dB
Re-selection
Coverage Based dB2(2dB),
dB5(5dB), dB1~16,
dB8~22, dB2~17,
dB10~23,
PERMIT_HO_ENU
dB3(3dB), PERMIT_HO_ENU
dB3~18, dB4~19,
Intra-frequency dB6(6dB), dB12~24, dB14~25,
M(Permit
dB4(4dB), Ho), M~0,
dB5~20, dB6~21,
Handover Enumeration values dB8(8dB), dB16~26, dB18~27, None
FORBID_HO_ENU
dB5(5dB), FORBID_HO_ENU
dB8~22, dB10~23,
Automatic Neighbor dB10(10dB),
PERMIT_RMV_EN dB20~28, dB22~29,
PERMIT_RMV_EN
M(Forbid
dB6(6dB), Ho) M~1
dB12~24,
Relation(ANR)
Automatic Neighbor dB12(12dB),
UM(Permit Rmv), dB24~30 dB14~25,
UM~0,
Enumeration values dB8(8dB), dB16~26, dB18~27, None
Relation(ANR) dB14(14dB),
FORBID_RMV_EN FORBID_RMV_EN
dB10(10dB),
BOOLEAN_FALSE(
dB16(16dB),
UM(Forbid Rmv) dB20~28, dB22~29,
BOOLEAN_FALSE
UM~1
Automatic
dB12(12dB),
False),
dB18(18dB), dB24~30
~0,
Neighbour Relation Enumeration values None
Coverage Based dB14(14dB),
BOOLEAN_TRUE(
dB20(20dB), BOOLEAN_TRUE~
(ANR)
Intra-frequency dB16(16dB),
True)
dB22(22dB), 1
Handover Character string dB18(18dB),
0~99 characters
dB24(24dB) Not involved None
Coverage
Automatic Based
Neighbor dB20(20dB),
Intra-frequency
Relation(ANR) dB22(22dB),
Handover Character string 0~99 characters
dB24(24dB) Not involved None
Automatic Neighbor
Relation(ANR)
None Interval values 0~11 Not involved None
Cell Selection and
Re-selection
3GPP R8 Based 0~39649,65336~65
Coverage Interval values Not involved None
Specifications 535
Inter-frequency
Cell Selection and
Handover NOT_CFG(Not
3GPP R8 NOT_CFG~0,
Re-selection Enumeration values configure), None
Specifications CFG~1
Coverage Based CFG(Configure)
Cell Selection and
Inter-frequency 18000~39649,6533
Re-selection
Handover Interval values Not involved None
6~65535
Coverage Based
Inter-frequency NOT_CFG(Not
Cell Selection and NOT_CFG~0,
Handover Enumeration values configure), None
Re-selection CFG~1
CFG(Configure)
Cell Selection and
Interval values 0~7 Not involved None
Re-selection
Cell Selection and
Interval values 0~7 Not involved s
Re-selection
NOT_CFG(Not
Cell Selection and NOT_CFG~0,
Enumeration values 0DOT25_ENUM(0.
configure), None
Re-selection 25), CFG~1
CFG(Configure) 0DOT25_ENUM~0,
0DOT5_ENUM(0.5)
Cell Selection and 0DOT5_ENUM~1,
Enumeration values 0DOT25_ENUM(0.
, None
Re-selection 25), 0DOT75_ENUM~2,
0DOT75_ENUM(0. 0DOT25_ENUM~0,
0DOT5_ENUM(0.5) 1DOT0_ENUM~3
Cell
3GPP Selection
R8 and 75), 0DOT5_ENUM~1,
Enumeration values MBW6(1.4M),
,1DOT0_ENUM(1.0) MBW6~0, None
Re-selection
Specifications 0DOT75_ENUM~2,
0DOT75_ENUM(0.
MBW15(3M), MBW15~1,
Cell Selection and 1DOT0_ENUM~3
75),
MBW25(5M), MBW25~2,
Re-selection Enumeration values 1DOT0_ENUM(1.0) MHz
MBW50(10M), MBW50~3,
Coverage Based
MBW75(15M), MBW75~4,
Inter-frequency
MBW100(20M) MBW100~5
Handover
12dB), dB-10(- dB-24~0, dB-22~1,
10dB), dB-8(-8dB), dB-20~2, dB-18~3,
dB-6(-6dB), dB-5(- dB-16~4, dB-14~5,
5dB), dB-4(-4dB), dB-12~6, dB-10~7,
dB-3(-3dB), dB-2(- dB-8~8, dB-6~9,
3GPP R8
2dB), dB-1(-1dB), dB-5~10, dB-4~11,
Specifications
dB0(0dB), dB-3~12, dB-2~13,
Cell Selection and
dB1(1dB), dB-1~14, dB0~15,
Re-selection Enumeration values dB
dB2(2dB), dB1~16, dB2~17,
Coverage Based
dB3(3dB), dB3~18, dB4~19,
Inter-frequency
Cell Selection and
Interval values dB4(4dB),
0~31 dB5~20, dB6~21,
Not involved 2dB
Handover
Re-selection dB5(5dB), dB8~22, dB10~23,
Cell Selection and dB6(6dB), dB12~24, dB14~25,
Interval values 0~31
dB8(8dB), Not involved
dB16~26, dB18~27, 2dB
Re-selection
dB10(10dB), dB20~28, dB22~29,
Cell Selection and dB12(12dB), dB24~30
Interval values -70~-22 Not involved 2dBm
Re-selection dB14(14dB),
dB16(16dB),
NOT_CFG(Not
Cell Selection and dB18(18dB), NOT_CFG~0,
Enumeration values configure), None
Re-selection dB20(20dB), CFG~1
CFG(Configure)
Cell Selection and dB22(22dB),
Interval values -30~33
dB24(24dB) Not involved dBm
Re-selection
Cell Selection and
BitString00(00), BitString00~0,
Re-selection
BitString01(01), BitString01~1,
Coverage Based Enumeration values None
Cell Selection and BitString10(10), BitString10~2,
Inter-frequency BOOLEAN_FALSE( BOOLEAN_FALSE
Re-selection BitString11(11) BitString11~3
Handover False), ~0,
Coverage Based Enumeration values None
BOOLEAN_TRUE( BOOLEAN_TRUE~
Inter-frequency
Coverage True) 1
Handover Based EventA3(EventA3), EventA3~0,
Inter-frequency Enumeration values None
EventA4(EventA4) EventA4~1
Handover
None Interval values 0~11 Not involved None
Cell Selection and
Re-selection
0~39649,65336~65
Coverage Based Interval values Not involved None
Cell Selection and 535
Inter-frequency
Re-selection
Handover
Coverage Based Interval values 0~503 Not involved None
Inter-frequency
Handover
None Interval values dB-24(-24dB),
0~11 dB- Not involved None
22(-22dB), dB-20(-
Coverage Based 20dB), dB-18(-
Inter-frequency Character string dB-24(-24dB),
dB-16(-dB-
3 characters
18dB), Not involved None
Handover 22(-22dB), dB-20(-
16dB), dB-14(-
Coverage Based 20dB), dB-18(-
14dB), dB-12(-
Inter-frequency Character string 2~3 characters
18dB), Not involved None
12dB), dB-16(-
dB-10(- dB-24~0, dB-22~1,
Handover 16dB),
Coverage Based 10dB), dB-14(-
dB-8(-8dB), dB-20~2, dB-18~3,
14dB), dB-12(-
dB-6(-6dB),
Inter-frequency Interval values 0~1048575 dB-5(- dB-16~4, dB-14~5,
Not involved None
12dB), dB-10(-
5dB), dB-4(-4dB), dB-24~0,
dB-12~6, dB-22~1,
dB-10~7,
Handover
Coverage Based 10dB), dB-8(-8dB),
dB-3(-3dB), dB-2(- dB-20~2, dB-18~3,
dB-8~8, dB-6~9,
Inter-frequency Interval values dB-6(-6dB),
0~255 dB-5(-
2dB), dB-1(-1dB), dB-16~4,
dB-5~10, dB-14~5,
Not involved
dB-4~11, None
Coverage
Handover Based 5dB), dB-4(-4dB), dB-12~6,
dB0(0dB), dB-3~12, dB-10~7,
dB-2~13,
Inter-frequency dB-3(-3dB),
dB1(1dB), dB-2(- dB-8~8,
dB-1~14,dB-6~9,
dB0~15,
Handover Enumeration values 2dB), dB-1(-1dB), dB-5~10, dB-4~11, dB
dB2(2dB), dB1~16, dB2~17,
Mobility Robust dB0(0dB), dB-3~12, dB-2~13,
dB3(3dB), dB3~18, dB4~19,
Optimization
Cell Selection and dB1(1dB), dB-1~14, dB0~15,
Enumeration values dB4(4dB), dB5~20, dB6~21, dB
Re-selection
Coverage Based dB2(2dB),
dB5(5dB), dB1~16,
dB8~22, dB2~17,
dB10~23,
PERMIT_HO_ENU
dB3(3dB), PERMIT_HO_ENU
dB3~18, dB4~19,
Inter-frequency dB6(6dB), dB12~24, dB14~25,
M(Permit
dB4(4dB), Ho), M~0,
dB5~20, dB6~21,
Handover Enumeration values dB8(8dB), dB16~26, dB18~27, None
FORBID_HO_ENU
dB5(5dB), FORBID_HO_ENU
dB8~22, dB10~23,
Automatic Neighbor dB10(10dB),
PERMIT_RMV_EN dB20~28, dB22~29,
PERMIT_RMV_EN
M(Forbid
dB6(6dB), Ho) M~1
dB12~24,
Relation(ANR)
Automatic Neighbor dB12(12dB),
UM(Permit Rmv), dB24~30 dB14~25,
UM~0,
Enumeration values dB8(8dB), dB16~26, dB18~27, None
Relation(ANR)
Coverage Based dB14(14dB),
FORBID_RMV_EN FORBID_RMV_EN
dB10(10dB),
dB16(16dB),
UM(Forbid Rmv) dB20~28,
UM~1 dB22~29,
Inter-frequency
dB12(12dB),
dB18(18dB), dB24~30
Handover Interval values 0~32 Not involved None
dB14(14dB),
dB20(20dB),
Cell Selection and BOOLEAN_FALSE( BOOLEAN_FALSE
Automatic dB16(16dB),
dB22(22dB),
Reselection False), ~0,
Neighbour Relation Enumeration values dB18(18dB),
dB24(24dB) None
BOOLEAN_TRUE(
dB20(20dB), BOOLEAN_TRUE~
(ANR)
True)
dB22(22dB), 1
dB24(24dB)
Coverage Based
Inter-frequency
Handover Character string 0~99 characters Not involved None
Coverage
Automatic Based
Neighbor
Inter-frequency
Relation(ANR)
Handover Based
Coverage Character string 0~99 characters Not involved None
Automatic Neighbor
Intra-frequency
Relation(ANR)
Handover
Coverage Character string 3 characters Not involved None
Coverage Based
Based
Intra-frequency
Inter-frequency
Handover
Handover
Coverage Character string 2~3 characters Not involved None
Coverage Based
Based
Intra-frequency
Inter-frequency
Handover
Handover
Coverage Interval values 0~1048575 Not involved None
Coverage Based
Based
Intra-frequency
Inter-frequency
Handover
Handover
Coverage Interval values 0~255 Not involved None
Coverage Based
Based
Intra-frequency
Inter-frequency
Handover
Handover 0~39649,65336~65
Coverage Interval values Not involved None
Coverage Based
Based 535
Intra-frequency
Inter-frequency NOT_CFG(Not
Handover
Handover NOT_CFG~0,
Coverage Enumeration values configure), None
Coverage Based
Based CFG~1
Intra-frequency CFG(Configure)
Inter-frequency
Handover
Handover 18000~39649,6533
Coverage Interval values Not involved None
Coverage Based
Based 6~65535
Intra-frequency
Inter-frequency
Handover
Handover
Coverage Interval values 0~503 Not involved None
Coverage Based
Based
Intra-frequency
Inter-frequency
Handover
Handover
Coverage Interval values 0~65535 Not involved None
Coverage Based
Based
Intra-frequency
Inter-frequency
Handover
Handover Character string 0~99 characters Not involved None
Coverage Based
Inter-frequency
Handover
None Interval values 0~11 Not involved None
PS Inter-RAT
Mobility between E-
Character string 3 characters Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E-
Character string 2~3 characters Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E-
Interval values 0~268435455 Not involved None
UTRAN and
PS Inter-RAT
UTRAN between E- PERMIT_HO_ENU PERMIT_HO_ENU
Mobility
M(Permit Ho), M~0,
UTRAN and Enumeration values None
FORBID_HO_ENU FORBID_HO_ENU
UTRAN
Automatic PERMIT_RMV_EN PERMIT_RMV_EN
M(Forbid Ho) M~1
Inter-RAT ANR
Neighbour Relation UM(Permit Rmv), UM~0,
Enumeration values None
(ANR) FORBID_RMV_EN FORBID_RMV_EN
Inter-RAT ANR UM(Forbid Rmv) UM~1
Mobility
Interval values 0~32 Not involved None
Management
Automatic BOOLEAN_FALSE( BOOLEAN_FALSE
Neighbour Relation False), ~0,
Enumeration values None
(ANR) BOOLEAN_TRUE( BOOLEAN_TRUE~
PS Inter-RAT
Inter-RAT ANR True) 1
Mobility between E-
Character string 0~99 characters Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E-
Character string 0~99 characters Not involved None
UTRAN and
UTRAN
None Interval values 0~11 Not involved None
Broadcast of
System Information
PS Inter-RAT
Mobility between E-
PS Inter-RAT Interval values 0~16383 Not involved None
UTRAN between
Mobility and E-
UTRAN and
UTRAN R99, HSDPA, R99~0, HSDPA~1,
Inter-RAT ANR Enumeration values None
UTRAN
PS Inter-RAT HSUPA, HSPA HSUPA~2, HSPA~3
Cell Selection
Mobility andE-
between
Reselection UTRAN_FDD, UTRAN_FDD~0,
UTRAN and
PS Inter-RAT Enumeration values None
UTRAN_TDD UTRAN_TDD~1
UTRAN between E-
Mobility
Inter-RAT ANR NOT_CFG(Not
UTRAN and
PS Inter-RAT NOT_CFG~0,
Enumeration values configure), None
UTRAN
Mobility between E- CFG~1
CFG(Configure)
Cell Selection
UTRAN and and
Reselection
UTRAN Interval values 0~16383 Not involved None
Cell Selection and
Reselection NOT_CFG(Not
Cell Selection and NOT_CFG~0,
Inter-RAT ANR Enumeration values configure), None
Reselection CFG~1
Cell Selection and CFG(Configure)
Reselection
Interval values 0~7 Not involved None
Broadcast of
System Information
Cell Selection and
Interval values -50~33 Not involved dBm
Reselection
PS Inter-RAT
Mobility between E-
UTRAN and Interval values -15~15 Not involved dB
UTRAN
Inter-RAT
Cell ANRand
Selection
Interval values -24~0 Not involved dB
Reselection
Cell Selection and
Interval values -60~-13 Not involved dBm
Reselection
Cell Selection and
Interval values 0~31 Not involved 2dB
Reselection
Cell Selection and
Interval values 0~31 Not involved 2dB
Reselection
PS Inter-RAT
Mobility between E-
Character string 3 characters Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E-
Character string 2~3 characters Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E-
Interval values 0~268435455 Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E- UTRAN_FDD, UTRAN_FDD~0,
Enumeration values None
UTRAN and UTRAN_TDD UTRAN_TDD~1
PS Inter-RAT
UTRAN
Mobility between E-
Interval values 0~16383 Not involved None
UTRAN and
PS Inter-RAT
UTRAN NOT_CFG(Not
Mobility between E- NOT_CFG~0,
Enumeration values configure), None
UTRAN and CFG~1
PS Inter-RAT CFG(Configure)
UTRAN
Mobility between E-
Interval values 0~16383 Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E-
Interval values 0~4095 Not involved None
UTRAN and
PS Inter-RAT
UTRAN NOT_CFG(Not
Mobility between E- NOT_CFG~0,
Enumeration values configure), None
UTRAN and CFG~1
PS Inter-RAT CFG(Configure)
UTRAN
Mobility between E-
Interval values 0~255 Not involved None
UTRAN and
UTRAN
PS Inter-RAT
Mobility between E-
Interval values 0~511 Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E-
Interval values 1~65533,65535 Not involved None
UTRAN and
PS Inter-RAT
UTRAN
Mobility between E-
Character string 0~99 characters Not involved None
UTRAN and
UTRAN
Automatic
Neighbour Interval values 0~100 Not involved %
Relation(ANR)
Automatic
Neighbour Interval values 0~100 Not involved %
Relation(ANR)
Automatic
Neighbour Interval values 1~10000 Not involved None
Relation(ANR)
Automatic
Neighbour Interval values 1~10080 120ms~0,
Not involved min
Relation(ANR) r1(1), r2(2), r4(4), 240ms~1,
Automatic r1~0, r2~1, r4~2,
480ms~2,
r8(8), r16(16),
Neighbour Enumeration values EutranVoipCapSwit
120ms, r8~3, r16~4, r32~5, None
r32(32), 240ms,
r64(64),
ch(EutranVoipCapS 640ms~3,
Relation(ANR) 480ms, 640ms, r64~6, Infinity~7
1024ms~4,
Automatic Infinity(Infinity)
witch),
1024ms, 2048ms, 2048ms~5,
Neighbour Enumeration values UtranVoipCapSwitc ms
5120ms, 10240ms,
h(UtranVoipCapSwi 5120ms~6,
Relation(ANR)
Automatic 1min,
tch), 6min, 12min, 10240ms~7,
Neighbour 30min, 60min 1min~8, 6min~9,
Interval values 1~10080
GeranVoipCapSwitc Not involved min
Relation(ANR)
Coverage Based 12min~10,
Automatic
Inter-RAT ANR
Intra-frequency h(GeranVoipCapSw
IntraFreqCoverHoS
Neighbour EutranVoipCapSwit
30min~11,
Handover Interval values itch),
witch(IntraFreqCov
-130~-70 Not involved dBm
Relation(ANR) ch~0,
60min~12
Coverage Based Cdma1xRttVoipCap
erHoSwitch),
Inter-RAT ANR UtranVoipCapSwitc
PS Inter-RAT
Automatic
Inter-frequency Switch(Cdma1xRttV
InterFreqCoverHoS h~1,
Mobility
Neighbour
Handover between E- Interval values oipCapSwitch),
1~200
witch(InterFreqCov Not involved None
GeranVoipCapSwitc
IntraFreqCoverHoS
UTRAN and
Relation(ANR)
PS Inter-RAT UtranPsHoSwitch(U
erHoSwitch), h~2,
witch~0,
UTRAN
Mobility between E- tranPsHoSwitch),
UtranCsfbSwitch(Ut
Inter-RAT ANR Interval values 1~200 Cdma1xRttVoipCap
Not involved
InterFreqCoverHoS None
PS Inter-RAT
UTRAN and GeranPsHoSwitch(
ranCsfbSwitch), Switch~3,
witch~1,
Mobility
UTRAN between E- GeranPsHoSwitch),
GeranCsfbSwitch(G
Automatic UtranPsHoSwitch~
UtranCsfbSwitch~2,
UTRAN
PS and
Inter-RAT CdmaHrpdNonOtpi
eranCsfbSwitch),
Neighbour Interval values 1~10000 Not
4, involved
GeranCsfbSwitch~3 None
GERAN
Mobility between E- misedHoSwitch(Cd
Cdma1xRttCsfbSwit
Relation(ANR) GeranPsHoSwitch~
,
PS Inter-RAT
UTRAN and maHrpdNonOtpimis
ch(Cdma1xRttCsfb 5,
Cdma1xRttCsfbSwit
Mobility
GERAN between
Inter-RAT ANR E- Interval values edHoSwitch),
1~10000
Switch),
IntraRatEventAnrS Not involved
IntraRatEventAnrS None
CdmaHrpdNonOtpi
ch~4,
UTRAN and
PS Inter-RAT CdmaHrpdOptimise
UtranServiceHoSwit
witch, witch~0,
misedHoSwitch~6,
UtranServiceHoSwit
CDMA2000
Mobility between E- dHoSwitch(CdmaHr
ch(UtranServiceHo
IntraRatFastAnrSwit IntraRatFastAnrSwit
Bit field type CdmaHrpdOptimise
ch~5, None
SRVCC
UTRAN andto UTRAN pdOptimisedHoSwit
Switch),
ch, ch~1,
dHoSwitch~7,
GeranServiceHoSw
SRVCC
CDMA2000 to GERAN ch),
GeranServiceHoSw
IntraRatAnrAutoDel IntraRatAnrAutoDel
Downlink Static DlIcicSwitch_OFF_ GeranNaccSwitch~
DlIcicSwitch_OFF_
itch~6,
Inter-RAT
SRVCC toLoad
UTRAN GeranNaccSwitch(
itch(GeranServiceH
Switch, Switch~2,
Inter-Cell Bit field type ENUM, 8,
ENUM~0,
CdmaHrpdServiceH None
Sharing
SRVCC to
to UTRAN
GERAN GeranNaccSwitch),
oSwitch),
UtranEventAnrSwitc UtranEventAnrSwitc
Interference DlIcicDynamicSwitc GeranNonNaccSwit
DlIcicDynamicSwitc
oSwitch~7,
Inter-RAT
Service Loadinter-
based GeranNonNaccSwit
CdmaHrpdServiceH
h, h~3,
Coordination h_ON_ENUM, ch~9,
h_ON_ENUM~1,
Cdma1xRttService
Sharing
PS
RAT to GERAN
Inter-RAT
handover to Enumeration values ch(GeranNonNaccS
oSwitch(CdmaHrpd
GeranEventAnrSwit GeranEventAnrSwit None
Downlink Dynamic DlIcicStaticSwitch_ UtranSrvccSwitch~
DlIcicStaticSwitch_
HoSwitch~8,
Service
Mobility
UTRAN
Automaticbased
between inter-
E- witch),
ServiceHoSwitch),
ch, ch~4,
Inter-Cell ON_ENUM, 10,
ON_ENUM~2,
UlPowerHoSwitch~
RAT
UTRAN handover
Service
Neighbourand
based to
inter-
Relation UtranSrvccSwitch(U
Cdma1xRttService
UtranFastAnrSwitch UtranFastAnrSwitch
Interference Bit field type DlIcicReuse3Switch GeranSrvccSwitch~
DlIcicReuse3Switch
9, None
UTRAN
RAT
(ANR) handover to tranSrvccSwitch),
,HoSwitch(Cdma1x ~5,
Coordination _ON_ENUM 11,
_ON_ENUM~3
InterPlmnHoSwitch
Service
PS based
ANR inter-
Inter-RAT
GERAN
Inter-RAT GeranSrvccSwitch(
RttServiceHoSwitch
GeranFastAnrSwitc GeranFastAnrSwitc
IntraFreqMroSwitch Cdma1xRttSrvccSw
LOAD_BASED_RE
~10
RAT
CS Fallback to to E-
handover
Mobility between GeranSrvccSwitch),
LOAD_BASED_RE
),
h, h~6,
Bit field type (IntraFreqMroAlgoS itch~12,
DIRECT_SWITCH~
IntraFreqMroSwitch None
GERAN
UTRAN
UTRAN and Cdma1xRttSrvccSw
DIRECT_SWITCH
UlPowerHoSwitch(
CdmaFastAnrSwitc CdmaFastAnrSwitc
witch), UtranRedirectSwitc
0
~0,
CS
CS Fallback
GERAN
Fallback to
to itch(Cdma1xRttSrvc
UlPowerHoSwitch),
h, h~7,
Mobility Robust InterFreqMroSwitch h~13,
InterFreqMroSwitch
UTRAN
PS Inter-RAT
GERAN Bit field type cSwitch),
InterPlmnHoSwitch(
UtranAutoNrtDelete UtranAutoNrtDelete None
Optimization (InterFreqMroAlgoS GeranRedirectSwitc
~1,
CS
CS Fallback
Mobility
3GPPFallback
R8 to
between
to E- UtranRedirectSwitc
InterPlmnHoSwitch)
Switch, Switch~8,
witch), h~14,
UtranMroSwitch~2,
GERAN
UTRAN and
CDMA2000 1xRTT
Specifications h(UtranRedirectSwit
GeranAutoNrtDelet GeranAutoNrtDelet
Bit field type UtranMroSwitch,
TpeAlgoSwitch CdmaHrpdRedirect
GeranMroSwitch~3
TpeAlgoSwitch~0 None
CS
TCPFallback
Proxy to
CDMA2000 ch),
eSwitch, eSwitch~9,
GeranMroSwitch Switch~15,
CDMA2000
Uplink 1xRTT
Dynamic
Enhancer(TPE) GeranRedirectSwitc
CdmaAutoNrtDelete CdmaAutoNrtDelete
UlIcicIntraSwitch(U Cdma1xRttRedirect
Inter-Cell h(GeranRedirectSw
Switch Switch~10
Bit field type plink Switch~16,
Interference itch), Intra-eNB ICIC UlIcicIntraSwitch~0 None
switch) BlindHoSwitch~17
Coordination CdmaHrpdRedirect
Switch(CdmaHrpdR
edirectSwitch),
Cdma1xRttRedirect
Switch(Cdma1xRtt
RedirectSwitch),
BlindHoSwitch(Blin
Uplink Static Inter-
Cell Interference
OFF(Off),
Coordination
STATIC(Static), OFF~0, STATIC~1,
Uplink Dynamic Enumeration values None
DYNAMIC(Dynamic DYNAMIC~2
Inter-Cell
)
Interference
LoCation Services OtdoaSwitch(OTDO
Coordination Bit field type OtdoaSwitch~0 None
(LCS) A switch)
Transport UlUuFlowCtrlSwitch
UlUuFlowCtrlSwitch
Differentiated Flow Bit field type (UU flow control None
~0
Control switch)
PCI Collision
Detection & Self- Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Optimization
Mobility Robust
Interval values 1~70000 Not involved min
Optimization (MRO)
Mobility Robust
Interval values 0~100 Not involved %
Optimization (MRO)
Mobility Robust
Interval values 0~10000 Not involved None
Optimization (MRO)
Mobility Robust
Interval values 1~60 Not involved s
Optimization (MRO)
Mobility Robust
Interval values 0~100 Not involved %
Optimization (MRO)

None Interval values 0~9 Not involved None

None Interval values 0~100 Not involved %

None Interval values 0~100 Not involved %

None Interval values 0~50000 Not involved ms

None Interval values 0~50000 Not involved ms

None Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None

None Interval values 0~261120 Not involved Ts

TCP Proxy
Interval values 0~20 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
TCP Proxy
Interval values 0~65535 Not involved None
Enhancer(TPE)
Public Key
Character string 1~127 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 1~128 characters Not involved None
Infrastructure(PKI)

Self-configuration Interval values 0~47 Not involved None

SGW~0,
Self-configuration Enumeration values SGW, X2eNodeB None
X2eNodeB~1

Self-configuration Enumeration values NO(No), YES(Yes) NO~0, YES~1 None

Self-configuration Interval values 0~47 Not involved None

Self-configuration Interval values 0~7 Not involved None

Self-configuration Interval values 0~1 Not involved None

Self-configuration Interval values 0~7 Not involved None


Self-configuration Enumeration values IP(IP) IP~1 None

Self-configuration Interval values 0~15 Not involved None


BASE_BOARD(Bas
BASE_BOARD~0,
e Board),
Self-configuration Enumeration values E1_COVERBOARD None
E1_COVERBOARD
~3
(E1 Cover Board)
Self-configuration Interval values 0~15
PPP(PPP Link), Not involved None
MPGRP(Multi-link
PPP~6, MPGRP~8,
PPP Group),
Self-configuration Enumeration values ETH~9, None
ETH(Ethernet Port),
ETHTRK~10
ETHTRK(Ethernet
Access Control Trunk)
Interval values 0~1 Not involved None
based on 802.1x
Access Control DEACTIVE(DEATIV DEACTIVE~0,
Enumeration values EAP- None
based on 802.1x E), ACTIVE(Active) ACTIVE~1
INVALID(Unconfigu
Access Control red authentic EAP-INVALID~0,
Enumeration values None
based on 802.1x method), EAP- EAP-TLS~13
TLS(EAP-TLS
Access Control authentic method)
Interval values 0~4294967295
NULL(NULL), Not involved None
based on 802.1x
LIC_OFF(License
Access Control Off),
Interval values 0~4294967295 Not involved None
based on 802.1x NOTIFY_FAIL(Notifi NULL~0,
UNAUTHENTICAT
cation LIC_OFF~1,
Access Control
Enumeration values ED(Unauthenticate
Authentication NOTIFY_FAIL~2, None
based on 802.1x d), UNAUTHENTICAT
Failed), NO_CERT~3,
Access Control AUTHENTICATING
NO_CERT(Certifica ED~0,
PORT_DOWN~6
Interval values 0~4294967295
(Authenticating),
te Not Exist), Not involved
AUTHENTICATING None
based on 802.1x
AUTHENTIC_SUC
PORT_DOWN(Tran ~1,
Access Control CEED(Authenticate AUTHENTIC_SUC
Enumeration values sport Not Activated) None
based on 802.1x Succeed), CEED~2,
AUTHENTIC_FAIL( AUTHENTIC_FAIL~
Access Control Authenticate Fail), 3,
Interval values 0~4294967295 Not involved None
based on 802.1x DHCP_AUTHENTI DHCP_AUTHENTI
Access Control CATING(DHCP CATING~4
Interval values 0~4294967295
Activation Not involved None
based on 802.1x
Authenticating)
RAN Sharing with
Interval values 1~100 Not involved %
Common Carrier
SHARING(Sharing),
RAN Sharing with SHARING~0,
Enumeration values DEDICATE(Dedicat None
Common Carrier DEDICATE~1
e)
RAN Sharing with
Interval values 0~100 Not involved %
Common Carrier
RAN Sharing with
Interval values 0~100 Not involved %
Common Carrier
RAN Sharing with
Interval values 0~100 Not involved %
Common Carrier
RAN Sharing with
Interval values 0~100 Not involved %
Common Carrier
RAN Sharing with
Interval values 0~100 Not involved %
Common Carrier
RAN Sharing with
Interval values 0~100 Not involved %
Common Carrier
RAN Sharing with
Interval values 0~100 Not involved %
Common Carrier
RAN Sharing with
Interval values 0~100 Not involved %
Common Carrier

Self-configuration Interval values 0~15 Not involved None

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Reliability IP address type Valid IP address Not involved None
SCTP Multi-homing
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC

Self-configuration Interval values 1024~65535 Not involved None

Self-configuration Character string 0~20 characters Not involved None

Self-configuration Interval values 0~3 Not involved None

Self-configuration Interval values 0~7 Not involved None

Self-configuration Interval values 0~1 Not involved None

Self-configuration Interval values 0~7 Not involved None

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC

Self-configuration Interval values 0~7 Not involved None

Self-configuration Interval values 0~1 Not involved None

Self-configuration Interval values 0~7 Not involved None


Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC
Self-configuration
Reliability IP address type Valid IP address Not involved None
SCTP Multi-homing
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC

Self-configuration Interval values 1024~65535 Not involved None

Self-configuration Interval values 1000~60000 Not involved ms

Self-configuration Interval values 1000~60000 Not involved ms

Self-configuration Interval values 1000~60000 Not involved ms

Self-configuration Interval values 1~99 Not involved None

Self-configuration Interval values 1~99 Not involved None

Self-configuration Interval values 1000~60000 Not involved None

Self-configuration Interval values 2~254 Not involved None

Self-configuration Interval values 1~253 Not involved None

DISABLE(Disable), DISABLE~0,
Self-configuration Enumeration values None
ENABLE(Enable) ENABLE~1
DISABLE(Disable), DISABLE~0,
Self-configuration Enumeration values None
ENABLE(Enable) ENABLE~1
ALDER32(ALDER3 ALDER32~0,
Self-configuration Enumeration values None
2), CRC32(CRC32) CRC32~1
DISABLE(Disable), DISABLE~0,
Self-configuration Enumeration values None
ENABLE(Enable) ENABLE~1

Self-configuration Interval values 1~254 Not involved None

Self-configuration Interval values 0~15 Not involved None

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC

Self-configuration Character string 0~20 characters Not involved None

Self-configuration Interval values 0~3 Not involved None

Self-configuration Interval values 0~7 Not involved None

Self-configuration Interval values 0~1 Not involved None

Self-configuration Interval values 0~7 Not involved None

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC

Self-configuration Interval values 0~7 Not involved None

Self-configuration Interval values 0~1 Not involved None

Self-configuration Interval values 0~7 Not involved None

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Reliability IP address type Valid IP address Not involved None
SCTP Multi-homing
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC
Self-configuration
Character string 0~15 characters Not involved None
IPSEC

Self-configuration Interval values 1024~65535 Not involved None

Self-configuration Interval values 1000~60000 Not involved ms

Self-configuration Interval values 1000~60000 Not involved ms

Self-configuration Interval values 1000~60000 Not involved ms

Self-configuration Interval values 1~99 Not involved None

Self-configuration Interval values 1~99 Not involved None


Self-configuration Interval values 1000~60000 Not involved None

Self-configuration Interval values 2~254 Not involved None

Self-configuration Interval values 1~253 Not involved None

DISABLE(Disable), DISABLE~0,
Self-configuration Enumeration values None
ENABLE(Enable) ENABLE~1
DISABLE(Disable), DISABLE~0,
Self-configuration Enumeration values None
ENABLE(Enable) ENABLE~1
ALDER32(ALDER3 ALDER32~0,
Self-configuration Enumeration values None
2), CRC32(CRC32) CRC32~1
DISABLE(Disable), DISABLE~0,
Self-configuration Enumeration values None
ENABLE(Enable) ENABLE~1

Self-configuration Interval values 1~254 Not involved None

Self-configuration Interval values 16~47 Not involved None

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC
Self-configuration
Reliability IP address type Valid IP address Not involved None
SCTP Multi-homing
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC

Self-configuration Interval values 1024~65535 Not involved None

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC

Self-configuration IP address type Valid IP address Not involved None


Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC

Self-configuration IP address type Valid IP address Not involved None

Self-configuration DISABLE(Disable), DISABLE~0,


Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration DISABLE(Disable), DISABLE~0,
Enumeration values None
IPSEC ENABLE(Enable) ENABLE~1
Self-configuration
IP address type Valid IP address Not involved None
IPSEC

Self-configuration Character string 0~0,3~3 characters Not involved None

Self-configuration Character string 0~0,2~3 characters Not involved None

Self-configuration Interval values 0~1048575 Not involved None

Self-configuration Character string 0~20 characters Not involved None

Self-configuration Interval values 0~3 Not involved None

Public Key ESN(ESN), ESN~0, MAC~1,


Enumeration values None
Infrastructure(PKI) MAC(MAC), IP(IP) IP~2
Public Key
Character string 0~32 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~0,2~2 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~64 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~64 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
DATA_ENCIPHER
MENT(DATA_ENCI
PHERMENT), DATA_ENCIPHER
DIGITAL_SIGNATU MENT~0,
RE(DIGITAL_SIGN DIGITAL_SIGNATU
Public Key ATURE), RE~1,
Bit field type None
Infrastructure(PKI) KEY_AGREEMENT KEY_AGREEMENT
(KEY_AGREEMEN ~2,
Public Key SHA1(SHA1),
Enumeration values T), KEY_ENCIPHERM
SHA1~0, MD5~1 None
Infrastructure(PKI) MD5(MD5)
KEY_ENCIPHERM ENT~3
KEYSIZE1024(KEY
Public Key ENT(KEY_ENCIPH
SIZE1024), KEYSIZE1024~0,
Enumeration values ERMENT) None
Infrastructure(PKI) KEYSIZE2048(KEY KEYSIZE2048~1
SIZE2048)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
IP address type Valid IP address Not involved None
Infrastructure(PKI)
Public Key
Character string 1~64 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Enumeration values IKE(IKE), SSL(SSL) IKE~0, SSL~1 None
Infrastructure(PKI)
Public Key
Character string 1~64 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~15 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters
NORMALLY(NORM Not involved None
Infrastructure(PKI)
ALLY),
NORMALLY~0,
Public Key ABNORMALITY(AB
Enumeration values ABNORMALITY~1, None
Infrastructure(PKI) NORMALITY),
FILENOTEXIST~2
FILENOTEXIST(Fil
Public Key
Enumeration values e not exist)SSL(SSL)
IKE(IKE), IKE~0, SSL~1 None
Infrastructure(PKI)
Public Key
Character string 1~64 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters
NORMALLY(NORM Not involved None
Infrastructure(PKI)
ALLY),
NORMALLY~0,
Public Key ABNORMALITY(AB
Enumeration values ABNORMALITY~1, None
Infrastructure(PKI) NORMALITY),
FILENOTEXIST~2
FILENOTEXIST(Fil
Public Key e not exist)
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 1~64 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters
NORMALLY(NORM Not involved None
Infrastructure(PKI)
ALLY),
NORMALLY~0,
Public Key ABNORMALITY(AB
Enumeration values ABNORMALITY~1, None
Infrastructure(PKI) NORMALITY),
FILENOTEXIST~2
FILENOTEXIST(Fil
Public Key e not exist)
Character string 0~128 characters Not involved None
Infrastructure(PKI) NORMAL(Normal),
Public Key CERTLOSS(Certific
Character string 1~64 characters
ate Loss), Not involved None
Infrastructure(PKI) NORMAL~0,
CERTDAMAGE(Ce
CERTLOSS~1,
Public Key rtificate Damage),
Enumeration values CERTDAMAGE~2, None
Infrastructure(PKI) UNKNOWFORMAT
UNKNOWFORMAT
(Unknow File
Public Key ~3, FAILED~4
Character string Format),
0~128 characters Not involved None
Infrastructure(PKI) FAILED(Other failed
Public Key Reason)
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~128 characters Not involved None
Infrastructure(PKI)
Public Key
IP address type Valid IP address Not involved None
Infrastructure(PKI)
Public Key
Character string 0~255 characters Not involved None
Infrastructure(PKI)
Public Key
Character string 0~255 characters Not involved None
Infrastructure(PKI)
Public Key
Interval values 0~65535 Not involved None
Infrastructure(PKI)
Public Key
Character string 1~64 characters Not involved None
Infrastructure(PKI)
Public Key DISABLE(Disable), DISABLE~0,
Enumeration values None
Infrastructure(PKI) ENABLE(Enable) ENABLE~1
Public Key
Interval values 8~240 Not involved h
Infrastructure(PKI)
Public Key
Interval values 0~3 Not involved None
Infrastructure(PKI)
Public Key FTP(FTP),
Enumeration values FTP~0, LDAP~1 None
Infrastructure(PKI) LDAP(LDAP)
Public Key
Character string 0~255 characters Not involved None
Infrastructure(PKI)
Public Key DISABLE(Disable), DISABLE~0,
Enumeration values None
Infrastructure(PKI) ENABLE(Enable) ENABLE~1
Public Key
Interval values 1~15 Not involved day
Infrastructure(PKI)
Public Key
Interval values 7~180 Not involved day
Infrastructure(PKI)
Public Key NOVERIFY(No
PROXY(PROXY),
Enumeration values Verifying), PROXY~0, CMP~1 None
Infrastructure(PKI) CMP(CMP)
ALARM(Send an
NOVERIFY~0,
Public Key Alarm If Verifying
Enumeration values ALARM~1, None
Infrastructure(PKI) CRL Failed),
DISCONNECT~2
DISCONNECT(Disc
None Interval values onnect If Verifying
20000~60000 Not involved ms
CRL Failed)

None Interval values 3~6 Not involved None

None Interval values 0~63 Not involved None


IPSEC
Access Control List Interval values 3000~3999 Not involved None
(ACL)
IPSEC
Access Control List Character string 0~127 characters Not involved None
(ACL)
IPSEC
Access Control List Interval values 3000~3999 Not involved None
(ACL)
IPSEC
Access Control List Interval values 1~65535 Not involved None
(ACL)
IPSEC
DENY(Deny), DENY~0,
Access Control List Enumeration values None
PERMIT(Permit)
IP(IP), PERMIT~1
(ACL)
IPSEC ICMP(ICMP), IP~0, ICMP~1,
Access Control List Enumeration values TCP(TCP), TCP~6, UDP~17, None
(ACL) UDP(UDP), SCTP~132
IPSEC SCTP(SCTP)
Access Control List IP address type Valid IP address Not involved None
(ACL)
IPSEC
valid wildcard of the
Access Control List Wildcard mask type Not involved None
IP address
(ACL) OP_LT(Less or
IPSEC
Access Control List Enumeration values Equal),
NO(No), YES(Yes) NO~0, YES~1 None
(ACL) OP_GT(Greater or OP_LT~1,
IPSEC Equal), OP_GT~2,
Access Control List Enumeration values OP_EQ(Equivalent) OP_EQ~3, None
(ACL) , OP_NEQ(Not OP_NEQ~4,
IPSEC Equivalent), OP_RANGE~5
Access Control List Interval values 0~65535
OP_RANGE(Range Not involved None
(ACL) )
IPSEC
Access Control List Interval values 0~65535 Not involved None
(ACL)
IPSEC
Access Control List IP address type Valid IP address Not involved None
(ACL)
IPSEC
valid wildcard of the
Access Control List Wildcard mask type Not involved None
IP address
(ACL) OP_LT(Less or
IPSEC
Access Control List Enumeration values Equal),
NO(No), YES(Yes) NO~0, YES~1 None
(ACL) OP_GT(Greater or OP_LT~1,
IPSEC Equal), OP_GT~2,
Access Control List Enumeration values OP_EQ(Equivalent) OP_EQ~3, None
(ACL) , OP_NEQ(Not OP_NEQ~4,
IPSEC Equivalent), OP_RANGE~5
Access Control List Interval values 0~65535
OP_RANGE(Range Not involved None
(ACL) )
IPSEC
Access Control List Interval values 0~65535 Not involved None
(ACL)
IPSEC
Access Control List Enumeration values NO(No), YES(Yes) NO~0, YES~1 None
(ACL)
IPSEC
Access Control List Interval values 0~63 Not involved None
(ACL)
IPSEC
Access Control List Enumeration values NO(No), YES(Yes) NO~0, YES~1 None
(ACL)
Bidirectional
Forwarding Interval values 0~7 Not involved None
Detection
Bidirectional
Forwarding Interval values 0~1 Not involved None
Detection
Bidirectional
Forwarding Interval values 6~7 Not involved None
Detection
Bidirectional
Forwarding Interval values 0~95 Not involved None
Detection
Bidirectional
Forwarding IP address type Valid IP address Not involved None
Detection
Bidirectional
Forwarding IP address type Valid IP address Not involved None
Detection SINGLE_HOP(Singl
Bidirectional
e Hop), SINGLE_HOP~0,
Forwarding Enumeration values None
MULTI_HOP(Multipl MULTI_HOP~1
Detection
Bidirectional e Hops)
Forwarding Interval values 10~1000 Not involved ms
Detection
Bidirectional
Forwarding Interval values 10~1000 Not involved ms
Detection
Bidirectional
Forwarding Interval values 3~10 Not involved None
Detection MAINTENANCE(M
Bidirectional
aintenance), MAINTENANCE~0,
Forwarding Enumeration values None
Bidirectional RELIABILITY(Relia RELIABILITY~1
Detection
Forwarding bility)
Detection Interval values 0~63 Not involved None
DiffServ QoS
Bidirectional
Support
Forwarding Enumeration values NO(No), YES(Yes) NO~0, YES~1 None
Detection
ADMINDOWN(Adm
Bidirectional ADMINDOWN~0,
in Down),
Forwarding Enumeration values DOWN~1, INIT~2, None
DOWN(Down),
DEMAND_MODE(D
Detection UP~3
DEMAND_MODE~
Bidirectional INIT(Init),
emand Mode),UP(Up)
1,
Forwarding Enumeration values ASYNCHRONOUS None
ASYNCHRONOUS
Detection _MODE(Asynchron
Bidirectional _MODE~2
ous Mode)
Forwarding Interval values 10~1000 Not involved ms
Detection
Bidirectional
Forwarding Interval values 10~1000 Not involved ms
Detection
Bidirectional NO_DIAGNOSTIC(
Forwarding Interval values 0~4294967295
No Diagnostic), Not involved ms
Detection CTRL_DECT_TIME
Bidirectional _EXPIRED(Control
Forwarding Interval values 0~4294967295
Detection Time Not involved None
Detection Expired),
Bidirectional
Forwarding Interval values ECHO_FUNC_FAIL
0~4294967295 Not involved None
Detection ED(Echo Function
Bidirectional Failed), NO_DIAGNOSTIC~
Forwarding Interval values 0~4294967295
NEIGHBOR_SIG_S Not involved
0, None
Detection ESSION_DOWN(N CTRL_DECT_TIME
Bidirectional eighbor Signaled _EXPIRED~1,
Forwarding Interval values 0~4294967295
Session Down), Not involved
ECHO_FUNC_FAIL None
Detection FORDWARDING_P ED~2,
Bidirectional
Forwarding Interval values LANE_RESET(For
0~4294967295 NEIGHBOR_SIG_S
Not involved None
Detection warding Plane ESSION_DOWN~3,
Bidirectional Reset), FORDWARDING_P
Forwarding Enumeration values PATH_DOWN(Path LANE_RESET~4, None
Detection Down), PATH_DOWN~5,
Bidirectional CONCATENATED_ CONCATENATED_
Forwarding Interval values 0~15
PATH_DOWN(Conc Not involved
PATH_DOWN~6, None
Detection atenated Path ADMIN_DOWN~7,
Ethernet
OAM(IEEE Character string Down),
1~43 characters REVERSE_CONCA
Not involved None
802.1ag) ADMIN_DOWN(Ad TENTATED_PATH_
Ethernet ministratively DOWN~8,
OAM(IEEE Character string Down),
1~43 characters PEER_ADMIN_DO
Not involved None
802.1ag) REVERSE_CONCA WN~9
Ethernet TENTATED_PATH_
OAM(IEEE Interval values 1~8191
DOWN(Reverse Not involved None
802.1ag) Concatenated Path
Ethernet
OAM(IEEE IP address type Down),
Valid IP address Not involved None
802.1ag) PEER_ADMIN_DO
Ethernet WN(Peer
OAM(IEEE Character string Administratively
1~43 characters Not involved None
802.1ag) Down)
Ethernet
OAM(IEEE Character string 1~43 characters Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~7 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~1 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 6~7 Not involved None
802.1ag)
Ethernet
OAM(IEEE Enumeration values NO(No), YES(Yes) NO~0, YES~1 None
802.1ag)
Ethernet
OAM(IEEE Interval values 1~4094 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~7 Not involved None
802.1ag) 10ms(10ms),
Ethernet 100ms(100ms), 10ms~2, 100ms~3,
OAM(IEEE Enumeration values 1s(1s), 10s(10s), 1s~4, 10s~5, None
802.1ag) 1min(1min), 1min~6, 10min~7
Ethernet 10min(10min)
OAM(IEEE Interval values 0~32 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~64 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Character string 1~43 characters Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~7 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values None Not involved None
802.1ag)
Ethernet
OAM(IEEE Character string 1~43 characters Not involved None
802.1ag)
Ethernet
OAM(IEEE Character string 1~43 characters Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 1~8191 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~7 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~1 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 6~7 Not involved None
802.1ag)
BASE_BOARD(Bas
None Enumeration values BASE_BOARD~0 None
e Board)
Ethernet ETH(Ethernet Port),
OAM(IEEE Enumeration values ETHTRK(Ethernet ETH~3, ETHTRK~4 None
802.1ag) Trunk)
Ethernet
OAM(IEEE Interval values 0~1 Not involved None
802.1ag)
Ethernet
DISABLE(Disable), DISABLE~0,
OAM(IEEE Enumeration values None
ENABLE(Enable) ENABLE~1
802.1ag)
Ethernet
OAM(IEEE Enumeration values NO(No), YES(Yes) NO~0, YES~1 None
802.1ag)
Ethernet
OAM(IEEE Interval values 1~4094 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~7 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Character string 1~43 characters Not involved None
802.1ag)
Ethernet
OAM(IEEE Character string 1~43 characters Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 1~8191 Not involved None
802.1ag)
Ethernet
OAM(IEEE Composite type 14 characters Not involved None
802.1ag)
Ethernet
NORMAL(Normal), NORMAL~1,
OAM(IEEE Enumeration values None
FAULT(Fault) FAULT~2
802.1ag)
Ethernet
OAM(IEEE Composite type 14 characters Not involved None
802.1ag)
Ethernet
OAM(IEEE Enumeration values NO(No), YES(Yes) NO~0, YES~1 None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.1ag)
Ethernet
OAM(IEEE Interval values 0~4 Not involved None
802.1ag) 22(22), 23(23), 22~22, 23~23,
Ethernet 67(67), 68(68), 67~67, 68~68,
OAM(IEEE IP address type Valid IP address
319(319), 320(320), Not involved
319~319, 320~320, None
802.1ag) 500(500), 500~500,
TCP(TCP Protocol),
Integrated Firewall Enumeration values 1110(1110), 1110~1110,
TCP~6, UDP~17 None
UDP(UDP Protocol)
1120(1120), 1120~1120,
2700(2700), 2700~2700,
Integrated Firewall Enumeration values 3784(3784), 3784~3784, None
4443(4443), 4443~4443,
4500(4500), 4500~4500,
4784(4784), 4784~4784,
17185(17185), 17185~17185,
30023(30023), 30023~30023,
33003(33003), 33003~33003,
45300(45300) 45300~45300
DISABLE(Disable), DISABLE~0,
Integrated Firewall Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None


BASE_BOARD(Bas
PPP(PPP BASE_BOARD~0,
e Board), Link),
None Enumeration values MPGRP(Multi-link E1_COVERBOARD None
E1_COVERBOARD
PPP Group), ~3
PPP~0, MPGRP~2,
(E1 Cover Board)
ETH(Ethernet Port), ETH~3,
None Enumeration values None
ETHTRK(Ethernet ETHTRK~4,
Trunk), LOOPINT~6
None Interval values LOOPINT(Loopbac
0~15 Not involved None
k Interface)

None IP address type Valid IP address Not involved None

None Subnet mask type Valid Mask address Not involved None
Chain Topology DISABLE(DISABLE
DISABLE~0,
Tree Topology Enumeration values ), None
ENABLE~1
Self-configuration ENABLE(ENABLE)
Chain Topology
Tree Topology IP address type Valid IP address Not involved None
Self-configuration
DISABLE(Disable), DISABLE~0,
Self-configuration Enumeration values None
ENABLE(Enable) ENABLE~1
IPPRECEDENCE(I
DiffServ QoS IPPRECEDENCE~
Enumeration values P Precedence), None
Support 0, DSCP~1
DSCP(DSCP)
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)

None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)
None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)

None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)

None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)

None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)

None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)

None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)

None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

DiffServ QoS
Interval values 0~63 Not involved None
Support
HQ(High Quality),
None Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)

None Interval values 0~100 Not involved %

None Interval values 0~1000 Not involved %

None Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None

None Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~5 Not involved None


E1_DOUBLE_FRA
None Interval values 0~7,255Double
ME(E1 Not involved None
Frames),
ALLPORT(All
E1_CRC4_MULTI_
Ports), ALLPORT~0,
None Enumeration values E1_UNBA(E1 E1_DOUBLE_FRA None
FRAME(E1 CRC4
SINGLEPORT(Sing SINGLEPORT~1
Unbalance), ME~0,
E1_UNBA~0,
Multiple
le Port) Frames),
OK(Available),
E1_BA(E1 E1_CRC4_MULTI_
E1_BA~1, T1~2,
None Enumeration values T1_SUPER_FRAM
LOCAL_LOOP(Loc None
Balance), T1(T1), FRAME~1,
UNKNOWN~42949
E(T1
al Super
Loop),
UNKNOWN(Unkno T1_SUPER_FRAM
67294
Frames),
REMOTE_LOOP(R
HDB3(E1
wn) HDB3 E~2,
None Enumeration values T1_EXTENDED_S
emote Loop), None
Code), AMI(E1/T1 T1_EXTENDED_S
UPER_FRAME(T1
PAYLOAD_LOOP(P OK~0,
HDB3~0, AMI~1,
AMI Code), UPER_FRAME~3,
Extended
ayload Super
Loop), LOCAL_LOOP~1,
B8ZS~2,
None Enumeration values B8ZS(T1 E1_MODIFY_CRC4 None
Frames), B8ZS
SINGLE_CH_LOO REMOTE_LOOP~2
UNKNOWN~42949
Code),
MASTER(Master _MULTIFRAME~4,
E1_MODIFY_CRC4
P(Single Channel ,67294
UNKNOWN(Unkno
Mode), UNKNOWN~42949
MASTER~0,
None Enumeration values _MULTIFRAME(Mo
Loop), LOS(Loss of PAYLOAD_LOOP~ None
wn)
SLAVE(Slave 67294
SLAVE~1
dify CRC4
Signal), Multiple
AIS(Alarm 3,
Mode)
Frames),
Indication Signal),
EXECUTELINKTES SINGLE_CH_LOO
None Enumeration values UNKNOWN(Unkno
LFA(Loss
TFlAG_0(No of Frame
Test), P~4, LOS~5,
EXECUTELINKTES None
wn)
Alignment),
EXECUTELINKTES AIS~6, LFA~7,
TFlAG_0~0,
RA(Remote Alarm
TFlAG_1(Offline RA~8, LMFA~9,
EXECUTELINKTES
None Enumeration values Indication), SLIP~10, None
Test), TFlAG_1~1,
LMFA(Loss of
EXECUTELINKTES OTHERS~11,
EXECUTELINKTES
None Enumeration values Multiframe
TFlAG_2(Online
NO(No), YES(Yes) BACKUP~12,
TFlAG_2~2
NO~0, YES~1 None
Alignment),
Test) PHYSICAL_LOOP~
SLIP(Slip), 13
None Interval values OTHERS(Other
0~720 Not involved min
Fault),
BACKUP(Backup),
E1_COVERBOARD E1_COVERBOARD
None Enumeration values PHYSICAL_LOOP( None
(E1 Cover Board) ~3
Physical Loop)
1E-3(1E-3), 1E-
1E-3~3, 1E-4~4,
None Enumeration values 4(1E-4), 1E-5(1E- None
1E-5~5, 1E-6~6
5), 1E-6(1E-6)
Ethernet
OAM(IEEE Interval values 0~7 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~1 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 6~7 Not involved None
802.3ah)
BASE_BOARD(Bas
None Enumeration values BASE_BOARD~0 None
e Board)
Ethernet
OAM(IEEE Enumeration values ETH(Ethernet Port) ETH~3 None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~1 Not involved None
802.3ah) PASSIVE(Passive
Ethernet
Mode), PASSIVE~0,
OAM(IEEE Enumeration values None
ACTIVE(Active ACTIVE~1
802.3ah)
Ethernet Mode)
10,20,50,100,200,5
OAM(IEEE Interval values Not involved ms
00,1000
802.3ah)
Ethernet
OAM(IEEE Interval values 64~1518 Not involved byte
802.3ah)
Ethernet
DISABLE(Disable), DISABLE~0,
OAM(IEEE Enumeration values None
ENABLE(Enable) ENABLE~1
802.3ah)
Ethernet
DISABLE(Disable), DISABLE~0,
OAM(IEEE Enumeration values None
ENABLE(Enable) ENABLE~1
802.3ah)
Ethernet
OAM(IEEE Interval values 1~60 Not involved s
802.3ah)
Ethernet
OAM(IEEE Interval values 1~65535
OAM3AH_SESSIO Not involved None
802.3ah) N_IDLE(Idle
Ethernet Phase),
OAM(IEEE Interval values 10~900
OAM3AH_SESSIO Not involved s
802.3ah) OAM3AH_SESSIO
Ethernet N_DISCOVER(Disc
N_IDLE~0,
OAM(IEEE Interval values over
1~900Phase), Not involved None
OAM3AH_SESSIO
802.3ah) OAM3AH_SESSIO
N_DISCOVER~1,
Ethernet N_DETECT(Detect
OAM3AH_SESSIO
OAM(IEEE Enumeration values Phase), None
N_DETECT~2,
802.3ah) OAM3AH_SESSIO
Ethernet OAM3AH_SESSIO
N_LB_LOCAL(Loop
OAM(IEEE Interval values 0~4294967295 N_LB_LOCAL~3,
Not involved None
back Response
802.3ah) OAM3AH_SESSIO
Ethernet Phase),
N_LB_REMOTE~4
OAM(IEEE Interval values OAM3AH_SESSIO
0~4294967295 Not involved None
802.3ah) N_LB_REMOTE(Lo
Ethernet opback Start
OAM(IEEE Interval values Phase)
0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
Ethernet
OAM(IEEE Interval values 0~4294967295 Not involved None
802.3ah)
None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 6~7 Not involved None

BASE_BOARD(Bas
None Enumeration values BASE_BOARD~0 None
e Board)

None Interval values 0~1 Not involved None


COPPER(Copper),
FIBER(Fiber), COPPER~0,
None Enumeration values None
AUTO(Automatic FIBER~1, AUTO~2
Detection)
None Interval values 10M(10M),
46~1800 Not involved byte
100M(100M),
1000M(1000M), 10M~0, 100M~1,
None Enumeration values AUTO(Automatic 1000M~2, AUTO~3, None
Negotiation), UNKNOWN~4
FULL(Full Duplex),
UNKNOWN(UNKN
None Enumeration values AUTO(Automatic
OWN) FULL~1, AUTO~2 None
Negotiation)
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
CLOSE(Close), CLOSE~0,
None Enumeration values None
OPEN(Open) OPEN~1

None Interval values 0~100 Not involved per mill

None Interval values 0~100 Not involved per mill

None Composite type 14 characters Not involved None

NOLOOP(No
UP(Up),
None Enumeration values Loop), UP~0, DOWN~1 None
DOWN(Down)
REMOTE(Remote NOLOOP~0,
Loopback), REMOTE~1,
None Enumeration values None
LOCAL(Local LOCAL~2,
Loopback), UNKNOWN~3
None Enumeration values UNKNOWN(Unkno
NO(No), YES(Yes) NO~0, YES~1 None
wn)
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte/s

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

None Interval values 0~10 Not involved byte/s

None Interval values 0~4294967295 Not involved None

None IP address type Valid IP address Not involved None

FORCE(FORCE), FORCE~0,
None Enumeration values None
AUTO(AUTO) AUTO~1
FORCE(FORCE), FORCE~0,
None Enumeration values None
AUTO(AUTO)
10M(10M), AUTO~1
100M(100M),
10M~0, 100M~1,
None Enumeration values 1000M(1000M), None
1000M~2, AUTO~3
AUTO(Automatic
HALF(Half Duplex),
Negotiation)
FULL(Full Duplex), HALF~0, FULL~1,
None Enumeration values None
AUTO(Automatic AUTO~2
FORCE(FORCE),
Negotiation) FORCE~0,
AUTO(AUTO),
10M(10M),
None Enumeration values AUTO~1, None
UNKNOWN(UNKN
100M(100M), UNKNOWN~2
OWN)
1000M(1000M), 10M~0, 100M~1,
None Enumeration values AUTO(Automatic
HALF(Half Duplex), 1000M~2, AUTO~3, None
Negotiation),
FULL(Full Duplex), UNKNOWN~4
UNKNOWN(UNKN HALF~0, FULL~1,
AUTO(Automatic
None Enumeration values OWN) AUTO~2, None
Negotiation),
UNKNOWN~3
Ethernet Link UNKNOWN(UNKN
Aggregation(IEEE Interval values OWN)
0~7 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~1 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 6~7 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~1 Not involved None
802.3ad) DISABLE(Disable
Ethernet Link
LACP), DISABLE~0,
Aggregation(IEEE Enumeration values None
ENABLE(Enable ENABLE~1
802.3ad)
Ethernet Link LACP)
DISABLE(Disable), DISABLE~0,
Aggregation(IEEE Enumeration values None
ENABLE(Enable) ENABLE~1
802.3ad)
BASE_BOARD(Bas
None Enumeration values BASE_BOARD~0 None
e Board)
Ethernet Link
Aggregation(IEEE Interval values 46~1800 Not involved byte
802.3ad)
Ethernet Link
UP(Up),
Aggregation(IEEE Enumeration values UP~0, DOWN~1 None
DOWN(Down)
802.3ad)
Ethernet Link
Aggregation(IEEE Composite type 14 characters Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Composite type 14 characters Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~2 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Character string 0~7 characters Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~2 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Character string 0~7 characters Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved packet
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved byte
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved packet
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved byte
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved packet
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved byte
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved packet
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved byte
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE IP address type Valid IP address Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~7 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~1 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 6~7 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~1 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~1 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~255 Not involved None
802.3ad)
Ethernet Link
Aggregation(IEEE Enumeration values NO(No), YES(Yes) NO~0, YES~1 None
802.3ad)
BASE_BOARD(Bas
None Enumeration values BASE_BOARD~0 None
e Board)
Ethernet Link
UP(Up),
Aggregation(IEEE Enumeration values UP~0, DOWN~1 None
DOWN(Down)
802.3ad)
Ethernet Link
Aggregation(IEEE Composite type 14 characters Not involved None
802.3ad) SHORT(Short
Ethernet Link Timeout), SHORT~0,
Aggregation(IEEE Enumeration values LONG(Long LONG~1, None
802.3ad) SHORT(Short
Timeout), NULL~255
Ethernet Link Timeout),
NULL(NULL) SHORT~0,
Aggregation(IEEE Enumeration values LONG(Long LONG~1, None
802.3ad) Timeout), NULL~255
Ethernet Link NULL(NULL)
Aggregation(IEEE Interval values 0~4294967295 Not involved packet
802.3ad)
Ethernet Link
Aggregation(IEEE Interval values 0~4294967295 Not involved packet
802.3ad)
None Interval values 10~254 Not involved None

None Interval values 0~39 Not involved None

None Interval values 0~39 Not involved None


Transport
DiffServ QoS
Overbooking Interval values 0~63 Not involved None
Support
Transport Resource
Overload Control
Different Transport Interval values 0~100 Not involved %
Paths based on
Different
QoS Grade Transport
HQ(High Quality),
Paths based
Intra-LTE Loadon Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)
QoS Grade
Balancing
Transport
Different Transport
Overbooking
Paths based on Interval values 0~100 Not involved %
Transport
QoS Grade
Different Transport
Differentiated Flow
Paths based on
Control Interval values 0~1000 Not involved %
QoS Grade
Transport Resource FLOW_CTRL(Flow
FLOW_CTRL~0,
Overload Control Control),
Enumeration values NON_FLOW_CTRL None
Transport Dynamic NON_FLOW_CTRL
~1
Flow Control (Non Flow Control)
Transport
Different Transport DISABLE(Disable), DISABLE~0,
Enumeration values None
Overbooking
Paths based on ENABLE(Enable) ENABLE~1
SINGLE_RATE(Sin
Enhanced
QoS Grade gle Rate), SINGLE_RATE~0,
Transmission
Intra-LTE LoadQoS Enumeration values None
DUAL_RATE(Dual DUAL_RATE~1
Management
Balancing Rate)
IPSEC Character string 0~31 characters Not involved None

IPSEC Interval values 0,20~28800 Not involved s


IPSEC Interval values 0,60~28800 Not involved s

None Interval values 0~63 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None

IPSEC Character string 1~15 characters Not involved None

IPSEC Interval values 1~99 Not involved None

IKE_V1(IKE V1), IKE_V1~1,


IPSEC Enumeration values None
IKE_V2(IKE V2) IKE_V2~2
MAIN(Main Mode),
MAIN~2,
IPSEC Enumeration values AGGRESSIVE(Agg None
AGGRESSIVE~4
ressive Mode)
IP(IP Identify),
IPSEC Enumeration values FQDN(Name IP~1, FQDN~2 None
Identify)
IPSEC IP address type Valid IP address Not involved None

IPSEC Character string 0~31 characters Not involved None

IPSEC Character string 0~127 characters Not involved None


DISABLE(Disable),
DISABLE~0,
IPSEC Enumeration values PERIODIC(Periodic None
PERIODIC~2
)
IPSEC Interval values 10~3600 Not involved s

IPSEC Interval values 3~30 Not involved s

IPSEC Interval values 3~10 Not involved None

IPSEC IP address type Valid IP address Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None

IPSEC Interval values 1~99 Not involved None


DES(DES),
DES~2, 3DES~3,
3DES(3DES),
AES128~11,
IPSEC Enumeration values AES128(AES128), None
AES192~12,
AES192(AES192),
AES256~13
AES256(AES256)
MD5(MD5),
SHA1(SHA1), MD5~4, SHA1~5,
IPSEC Enumeration values None
AES_XCBC_96(AE
PRE_SHARED_KE AES_XCBC_96~6
DH_GROUP1(768-
S_XCBC_96)
Y(Pre-shared Key), PRE_SHARED_KE
IPSEC Enumeration values bit Diffie-Hellman
IKE_RSA_SIG(RSA Y~8, None
Group),
Digital Certificate IKE_RSA_SIG~9
DH_GROUP2(1024
Signature) DH_GROUP1~6,
IPSEC Enumeration values -bit Diffie-Hellman DH_GROUP2~7, None
Group), DH_GROUP14~14
DH_GROUP14(204
IPSEC Interval values 60~604800
HMAC_MD5(HMAC
8-bit Diffie-Hellman Not involved s
_MD5),
Group) HMAC_MD5~14,
HMAC_SHA1(HMA
IPSEC Enumeration values HMAC_SHA1~15, None
C_SHA1),
AES128_XCBC~18
AES128_XCBC(AE
None Interval values S128_XCBC)
0~7 Not involved None

None Interval values 0~1 Not involved None

None
IP-Based Multi- Interval values 0~7 Not involved None
mode Co-
Transmission on BS
IP-Based Multi- Interval values 0~7 Not involved None
side(eNodeB)
mode
2G/3GCo-
and LTE Co-
Transmission
transmission on BS
IP-Based Multi- Interval values 0~1 Not involved None
side(eNodeB)
mode
2G/3GCo-
and LTE Co-
Transmission
transmission on BS
IP-Based Multi- Interval values 0~7 Not involved None
side(eNodeB)
mode
2G/3GCo-
and LTE Co-
Transmission
transmission on BS
IP-Based Multi- Interval values 0~15 Not involved None
side(eNodeB)
mode
2G/3GCo-
and LTE Co-
Transmission
transmission on BS
IP-Based Multi- IP address type Valid IP address Not involved None
side(eNodeB)
mode
2G/3GCo-
and LTE Co-
Transmission
transmission on BS Subnet mask type Valid Mask address Not involved None
side(eNodeB)
2G/3G and LTE Co-
transmission
None Enumeration values IP(IP) IP~1 None
BASE_BOARD(Bas
BASE_BOARD~0,
e Board),
None Enumeration values PPP(PPP Link), E1_COVERBOARD None
E1_COVERBOARD
MPGRP(Multi-link ~3
(E1 Cover Board)
PPP Group), PPP~0, MPGRP~2,
None Enumeration values None
ETH(Ethernet Port), ETH~3, ETHTRK~4
ETHTRK(Ethernet
None Interval values Trunk)
0~15 Not involved None
Enhanced
Transmission QoS Interval values 0~65535 Not involved None
Management
None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7


PPP(PPP Link), Not involved None
MPGRP(Multi-link
Enhanced
PPP Group), PPP~0, MPGRP~2,
Transmission QoS Enumeration values None
ETH(Ethernet Port), ETH~3, ETHTRK~4
Management
ETHTRK(Ethernet
Trunk)
Enhanced
Transmission QoS Interval values 0~15 Not involved None
Management
Enhanced
QOS(QOS),
Transmission QoS Enumeration values QOS~0, ANY~1 None
ANY(ANY)
Management
Enhanced
Transmission QoS Interval values 0~63 Not involved None
Management
Enhanced
Transmission QoS IP address type Valid IP address Not involved None
Management
Enhanced
Transmission QoS IP address type Valid IP address Not involved None
Management
Enhanced
Transmission QoS Interval values 0~47 Not involved None
Management
Enhanced
HQ(High Quality),
Transmission QoS Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)
Management
Enhanced
Transmission QoS Enumeration values S1(S1), X2(X2) S1~0, X2~1 None
Management
Enhanced
DISABLE(Disable), DISABLE~0,
Transmission QoS Enumeration values None
ENABLE(Enable) ENABLE~1
Management
None Interval values 0~4294967295 Not involved Kbit/s

None Interval values 0~4294967295 Not involved Kbit/s

None Interval values 0~4294967295 Not involved Kbit/s

None Interval values 0~4294967295 Not involved Kbit/s

None Interval values 0~4294967295 Not involved Kbit/s

None Interval values 0~4294967295 Not involved Kbit/s


NORMAL(Normal),
NORMAL~0,
FAULT(Fault),
FAULT~1,
None Enumeration values CHECK_DISABLE None
CHECK_DISABLE
D(IP Path Check
D~2
Disabled)
None Interval values 0~15 Not involved None

None Character string 0~47 characters Not involved None


BASE_BOARD(Bas
BASE_BOARD~0,
e Board),
None Enumeration values E1_COVERBOARD None
E1_COVERBOARD
~3
(E1 Cover Board)
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
Differernt Transport
Paths based on IP address type Valid IP address Not involved None
Qos Grade
Differernt Transport
Paths based on IP address type Valid IP address Not involved None
Qos Grade
Differernt Transport
HQ(High Quality),
Paths based on Enumeration values HQ~0, LQ~1 None
LQ(Low Quality)
Qos Grade
Differernt Transport
Paths based on IP address type Valid IP address Not involved None
Qos Grade
IP Performance
Interval values 0~65535 Not involved None
Monitoring
IP Performance
IP address type Valid IP address Not involved None
Monitoring
IP Performance
IP address type Valid IP address Not involved None
Monitoring
IP Performance
Interval values 0~63 Not involved None
Monitoring
IP Performance UP(Uplink),
Enumeration values UP~1, BIDIR~2 None
Monitoring BIDIR(Bidirection)

None Interval values 0~10000 Not involved ms

None Interval values -10000~10000 Not involved ms

None Interval values -10000~10000 Not involved ms

None Interval values 0~1000 Not involved per mill

None Interval values 0~1000


IDLE(IDLE), Not involved per mill
IDLE~0,
ACTING(ACTING),
ACTING~1,
PMUP(IP PM UP),
None Enumeration values IDLE(IDLE), PMUP~2, None
DEACTING(DEACT IDLE~0,
ACTING(ACTING), DEACTING~3,
ING), ACTING~1,
PMUP(IP PM UP), UNKNOWN~255
None Enumeration values UNKNOWN(NULL) PMUP~2, None
DEACTING(DEACT
FOUR_TUPLE(FO DEACTING~3,
ING),
UR_TUPLE), UNKNOWN~255
FOUR_TUPLE~0,
None Enumeration values UNKNOWN(NULL) None
THREE_TUPLE(TH THREE_TUPLE~2
REE_TUPLE)
None Enumeration values NO(No), YES(Yes) NO~0, YES~1 None

None Interval values 0~65535 Not involved None

None Enumeration values NO(No), YES(Yes) NO~0, YES~1 None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Composite type None Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None


BASE_BOARD(Bas
PPP(PPP Link), BASE_BOARD~0,
e Board),
MPGRP(Multi-link
None Enumeration values E1_COVERBOARD None
E1_COVERBOARD
PPP Group), ~3
PPP~0, MPGRP~2,
(E1 Cover Board)
ETH(Ethernet Port),
ETH~3,
None Enumeration values ETHTRK(Ethernet None
ETHTRK~4,
Trunk),
LOOPINT~6, VI~7
LOOPINT(Loopbac
None Interval values 0~32
k Interface), Not involved None
VI(Virtual Interface)
NEXTHOP(Next
None Enumeration values Hop), IF(Exit NEXTHOP~0, IF~1 None
Interface)
None IP address type Valid IP address Not involved None

None Subnet mask type Valid Mask address Not involved None

None IP address type Valid IP address Not involved None


STATICHOST(Stati
None Interval values c1~255
Host Route), Not involved None
STATICGATEWAY(
STATICHOST~1,
Static Gateway
STATICGATEWAY~
None Enumeration values Route), None
2, HOST~3,
HOST(Dynamic
PPP(PPP Link), GATEWAY~4
Host Route),
MPGRP(Multi-link
None Character string 0~47 characters
GATEWAY(Dynami Not involved None
PPP Group),
cETH(Ethernet
Gateway Route) PPP~0, MPGRP~2,
Port),
ETH~3,
None Enumeration values ETHTRK(Ethernet None
ETHTRK~4,
Trunk),
LOOPINT~6, VI~7
LOOPINT(Loopbac
None Interval values 0~32
k Interface), Not involved None
VI(Virtual Interface)
None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 6~7 Not involved None

BASE_BOARD(Bas
None Enumeration values BASE_BOARD~0 None
e Board)
ETH(Ethernet Port),
IPSEC Enumeration values ETHTRK(Ethernet ETH~3, ETHTRK~4 None
Trunk)
IPSEC Interval values 0~1 Not involved None

IPSEC Character string 0~15 characters Not involved None

IPSEC Character string 1~15 characters Not involved None

IPSEC Interval values 1~10000 Not involved None

IPSEC Interval values 3000~3999 Not involved None

IPSEC Character string 0~15 characters Not involved None


IPSEC Character string DISABLE(Disable),
0~15 characters Not involved None
PFS_GROUP1(768
-bit Diffie-Hellman DISABLE~0,
IPSEC Enumeration values Group), PFS_GROUP1~1, None
PFS_GROUP2(102
GLOBAL(Global PFS_GROUP2~2
4-bit Diffie-Hellman
Configuration), GLOBAL~0,
IPSEC Enumeration values Group) None
LOCAL(Local LOCAL~1
Configuration)
IPSEC Interval values 30~604800 Not involved s

0,1843200~429496
None Interval values Not involved KB
7295

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None

IPSEC Character string 1~15 characters Not involved None


TUNNEL(Tunnel),
TUNNEL~0,
IPSEC Enumeration values TRANSPORT(Tran None
TRANSPORT~1
sport)
AH(AH Protocol),
ESP(ESP Protocol), AH~0, ESP~1,
IPSEC Enumeration values None
AH_ESP(AH/ESP AH_ESP~2
Protocol)
NULL(NULL),
NULL~0, MD5~1,
IPSEC Enumeration values MD5(MD5), None
SHA1~2
SHA1(SHA1)
NULL(NULL),
NULL~0, MD5~1,
IPSEC Enumeration values MD5(MD5),
NULL(NULL), None
SHA1~2 DES~1,
NULL~0,
SHA1(SHA1)
DES(DES),
3DES~2,
3DES(3DES),
IPSEC Enumeration values AES128~6, None
AES128(AES128),
AES192~7,
AES192(AES192),
AES256~8
None Interval values AES256(AES256)
0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None

DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
UP(Up),
None Enumeration values UP~0, DOWN~1 None
DOWN(Down)

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved packet


None IP address type Valid IP address Not involved None

None Subnet mask type Valid Mask address Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None


Transport MPGRP(Multi-link
Overbooking PPP Group),
MPGRP~2, ETH~3,
Transport Enumeration values ETH(Ethernet Port), None
Transport ETHTRK~4
Differentiated Flow ETHTRK(Ethernet
Overbooking
Control Trunk)
Transport Interval values 0~3 Not involved None
Transport
Differentiated Flow
Overbooking
Control DISABLE(Disable), DISABLE~0,
Transport Enumeration values None
Transport ENABLE(Enable) ENABLE~1
Differentiated Flow
Overbooking
Control
Transport Interval values 32~360000 Not involved Kbit/s
Transport
Differentiated Flow
Overbooking
Control
Transport Interval values 32~300000 Not involved Kbit
Transport
Differentiated Flow
Overbooking
Control
Transport Interval values 0~300000 Not involved Kbit
Differentiated Flow BASE_BOARD(Bas
Control BASE_BOARD~0,
e Board),
None Enumeration values E1_COVERBOARD None
Transport E1_COVERBOARD
~3
Overbooking (E1 Cover Board)
Transport Interval values 32~540000 Not involved Kbit/s
Differentiated Flow
Control
None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~5 Not involved None

ML-PPP/MC-PPP Interval values 0~3 Not involved None


Compression &
Multiplexing over DISABLE(Disable), DISABLE~0,
Enumeration values NONAUTH(No None
E1/T1 ENABLE(Enable) ENABLE~1
ML/MC-PPP Authentication),
PAP(PAP NONAUTH~0,
ML-PPP/MC-PPP Enumeration values None
Authentication), PAP~1, CHAP~2
CHAP(CHAP
ML-PPP/MC-PPP Character string Authentication)
0~67 characters Not involved None

ML-PPP/MC-PPP Character string 0~19 characters Not involved None

ML-PPP/MC-PPP IP address type Valid IP address Not involved None

ML-PPP/MC-PPP Subnet mask type Valid Mask address Not involved None
ML-PPP/MC-PPP IP address type Valid IP address Not involved None

LONG(Long), LONG~0,
ML-PPP/MC-PPP Enumeration values None
SHORT(Short) SHORT~1
DISABLE(Disable), DISABLE~0,
ML-PPP/MC-PPP Enumeration values None
ENABLE(Enable) ENABLE~1

ML-PPP/MC-PPP Interval values 128~1500 Not involved byte


Compression &
Multiplexing over
Interval values 1~512 Not involved byte
E1/T1
Compression
PPP MUX &
Multiplexing over
Interval values 3~1500 Not involved byte
E1/T1
Compression
PPP MUX &
Multiplexing over
Interval values 1~1000 Not involved ms
E1/T1
Compression
PPP MUX &
Multiplexing over
Interval values 4,8 Not involved None
E1/T1
ML/MC-PPP
Compression &
DISABLE(Disable), DISABLE~0,
Multiplexing over Enumeration values None
ENABLE(Enable) ENABLE~1
E1/T1
INITIAL(INITIAL),
IP Header
Interval values 0~1000
STARTING(STARTI Not involved per mill
Compression
NG),
INITIAL(INITIAL),
CLOSED(CLOSED)
ML-PPP/MC-PPP Interval values 0~1000
STARTING(STARTI
, Not involved per mill
NG), INITIAL~1,
STOPPED(STOPP
CLOSED(CLOSED)
UP(Up), STARTING~2,
None Enumeration values ED), UP~1, DOWN~2 None
,DOWN(Down) CLOSED~3,
CLOSING(CLOSIN INITIAL~1,
STOPPED(STOPP STOPPED~4,
G), STARTING~2,
ED), CLOSING~5,
None Enumeration values STOPPING(STOPP CLOSED~3, None
CLOSING(CLOSIN STOPPING~6,
ING), STOPPED~4,
G), REQSENT~7,
REQSENT(REQSE CLOSING~5,
None Enumeration values STOPPING(STOPP ACKRCVD~8, None
NT), STOPPING~6,
ING), ACKSENT~9,
ACKRCVD(ACKRC REQSENT~7,
REQSENT(REQSE OPENED~10
None IP address type VD),
Valid IP address ACKRCVD~8,
Not involved None
NT),
ACKSENT(ACKSE ACKSENT~9,
ACKRCVD(ACKRC
NT), OPENED~10
None IP address type VD),
OPENED(OPENED
Valid IP address Not involved None
ACKSENT(ACKSE
)
NT),
None IP address type OPENED(OPENED
Valid IP address Not involved None
)
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 128~1500 Not involved byte

DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte/s

None Interval values 0~4294967295 Not involved byte/s

None Interval values 0~4294967295 Not involved None

None IP address type Valid IP address Not involved None

E1_COVERBOARD E1_COVERBOARD
None Enumeration values None
(E1 Cover Board) ~3

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~5 Not involved None


TS1(Time Slot 1),
TS2(Time Slot 2),
ML-PPP/MC-PPP Interval values 0~15
TS3(Time Slot 3), Not involved None
TS4(Time Slot 4),
TS1~0, TS2~1,
ML-PPP/MC-PPP Interval values TS5(Time
0~3 Slot 5), Not involved None
TS3~2, TS4~3,
TS6(Time Slot 6),
TS5~4, TS6~5,
TS7(Time Slot 7),
TS7~6, TS8~7,
ML-PPP/MC-PPP Interval values 0~1
TS8(Time Slot 8), Not involved None
TS9~8, TS10~9,
TS9(Time Slot 9),
TS11~10, TS12~11,
TS10(Time Slot10),
ML-PPP/MC-PPP Interval values 0~5 TS13~12,
Not involved None
TS11(Time Slot11),
TS14~13,
TS12(Time Slot12),
TS15~14,
ML-PPP/MC-PPP Interval values TS13(Time
0~7 Slot13), Not involved None
TS16~15,
TS14(Time Slot14),
TS17~16,
TS15(Time Slot15),
TS18~17,
ML-PPP/MC-PPP Bit field type TS16(Time Slot16), None
TS19~18,
TS17(Time Slot17),
TS20~19,
TS18(Time Slot18),
ML-PPP/MC-PPP Interval values 128~1500 TS21~20,
Not involved byte
TS19(Time Slot19),
TS22~21,
TS20(Time Slot20),
TS23~22,
TS21(Time Slot21),
TS24~23,
TS22(Time Slot22),
TS25~24,
TS23(Time Slot23),
TS26~25,
TS24(Time Slot24),
TS27~26,
TS25(Time Slot25),
TS28~27,
TS26(Time Slot26),
TS29~28,
Compression &
DISABLE(Disable), DISABLE~0,
Multiplexing over Enumeration values None
ENABLE(Enable) ENABLE~1
E1/T1
Compression &
DISABLE(Disable), DISABLE~0,
Multiplexing over Enumeration values None
ENABLE(Enable) ENABLE~1
E1/T1
ML-PPP/MC-PPP Interval values 1~65535 Not involved ms
INITIAL(INITIAL),
E1_COVERBOARD E1_COVERBOARD
None Enumeration values STARTING(STARTI None
(E1 Cover Board) ~3
NG),
CLOSED(CLOSED)
E1_COVERBOARD E1_COVERBOARD
None Enumeration values , None
(E1 Cover Board) ~3
INITIAL~1,
STOPPED(STOPP
UP(Up), STARTING~2,
None Enumeration values ED), UP~1, DOWN~2
CLOSED~3, None
DOWN(Down)
CLOSING(CLOSIN
STOPPED~4,
G),
CLOSING~5,
None Enumeration values STOPPING(STOPP None
STOPPING~6,
ING),
REQSENT~7,
REQSENT(REQSE
None Interval values 128~1500 ACKRCVD~8,
Not involved byte
NT),
ACKSENT~9,
ACKRCVD(ACKRC
DISABLE(Disable), OPENED~10
DISABLE~0,
None Enumeration values VD), None
ENABLE(Enable)
ACKSENT(ACKSE ENABLE~1
NT),
DISABLE(Disable), DISABLE~0,
None Enumeration values OPENED(OPENED None
ENABLE(Enable) ENABLE~1
)
E1_COVERBOARD E1_COVERBOARD
None Enumeration values None
(E1 Cover Board) ~3

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

MASTER(Master), MASTER~0,
None Enumeration values None
SLAVE(Slave) SLAVE~1

None IP address type Valid IP address Not involved None

None IP address type Valid IP address Not involved None

None IP address type Valid IP address Not involved None


None IP address type Valid IP address Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None

None Enumeration values IPV4(IPV4) IPV4~1 None

Centralized M2000
Enumeration values NO(No), YES(Yes) NO~0, YES~1 None
Management
Centralized M2000
IP address type Valid IP address Not involved None
Management
Centralized M2000
IP address type Valid IP address Not involved None
Management
NEXTHOP(Next
None Enumeration values NEXTHOP~0 None
Hop)

None Interval values 1~255 Not involved None

None IP address type Valid IP address Not involved None


NORMAL(Normal),
ABNORMAL(Abnor NORMAL~0,
None Enumeration values mal), ABNORMAL~1, None
UNKNOWN(Unkno UNKNOWN~2
wn)
INUSE(In Use), INUSE~0,
None Enumeration values None
UNUSED(Unused) UNUSED~1
BASE_BOARD(Bas
None Enumeration values BASE_BOARD~0 None
e Board)
Access Control
Interval values 0~7 Not involved None
List(ACL)
Access Control
Interval values 0~1 Not involved None
List(ACL)
Access Control
Interval values 6~7 Not involved None
List(ACL)
ETH(Ethernet Port),
Access Control
Enumeration values ETHTRK(Ethernet ETH~3, ETHTRK~4 None
List(ACL)
Trunk)
Access Control
Interval values 0~3 Not involved None
List(ACL)
Access Control
Interval values 3000~3999 Not involved None
List(ACL)
PERMIT(Permit), PERMIT~0,
Integrated Firewall Enumeration values None
DENY(Deny) DENY~1
BASE_BOARD(Bas
None Enumeration values BASE_BOARD~0 None
e Board)
Access Control
Interval values 0~4294967295 Not involved packet
List(ACL)
Access Control
Interval values 0~4294967295 Not involved packet
List(ACL)
Access Control
Interval values 0~4294967295 Not involved packet
List(ACL)
Access Control
Interval values 0~4294967295 Not involved packet
List(ACL)
Access Control
Interval values 0~4294967295 Not involved packet
List(ACL)
Access Control
Interval values 0~4294967295 Not involved packet
List(ACL)

Integrated Firewall Interval values 0~4294967295 Not involved byte

Integrated Firewall Interval values 0~4294967295 Not involved byte

Integrated Firewall Interval values 0~4294967295 Not involved byte

Integrated Firewall Interval values 0~4294967295 Not involved byte

Integrated Firewall Interval values 0~4294967295 Not involved byte

Integrated Firewall Interval values 0~4294967295 Not involved byte

Integrated Firewall Interval values 0~4294967295 Not involved byte

Integrated Firewall Interval values 0~4294967295 Not involved packet

Integrated Firewall IP address type Valid IP address Not involved None

Integrated Firewall Subnet mask type Valid Mask address Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None


BASE_BOARD(Bas
BASE_BOARD~0,
e Board),
None Enumeration values E1_COVERBOARD None
E1_COVERBOARD
~3
(E1 Cover Board)
ETH(Ethernet Port),
Integrated Firewall Enumeration values ETH~0, E1T1~1 None
E1T1(E1/T1 Port)

Integrated Firewall Interval values 0~7 Not involved None

DISABLE(Disable), DISABLE~0,
Integrated Firewall Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 0~7 Not involved None


None Interval values 0~1 Not involved None

None Interval values 0~5 Not involved None


TS1(Time Slot 1),
TS2(Time Slot 2),
None Interval values 0~15
TS3(Time Slot 3), Not involved None
TS4(Time Slot 4),
TS1~0, TS2~1,
None Interval values TS5(Time
0~7 Slot 5), Not involved None
NONAUTH(No TS3~2, TS4~3,
TS6(Time Slot 6),
Authentication), TS5~4, TS6~5,
TS7(Time Slot 7),
PAP(PAP NONAUTH~0,
TS7~6, TS8~7,
None Enumeration values TS8(Time Slot 8), None
Authentication), PAP~1, TS10~9,
TS9~8, CHAP~2
TS9(Time Slot 9),
CHAP(CHAP TS11~10, TS12~11,
TS10(Time Slot10),
None Character string Authentication)
0~67 characters TS13~12,
Not involved None
TS11(Time Slot11),
TS14~13,
TS12(Time Slot12),
TS15~14,
None Character string TS13(Time Slot13),
0~19 characters Not involved None
TS16~15,
TS14(Time Slot14),
TS17~16,
TS15(Time Slot15),
TS18~17,
None Bit field type TS16(Time Slot16), None
TS19~18,
TS17(Time Slot17),
TS20~19,
TS18(Time Slot18),
None IP address type Valid IP address TS21~20,
Not involved None
TS19(Time Slot19),
TS22~21,
TS20(Time Slot20),
TS23~22,
None Subnet mask type TS21(Time Slot21),
Valid Mask address Not involved
TS24~23, None
TS22(Time Slot22),
TS25~24,
TS23(Time Slot23),
TS26~25,
None IP address type TS24(Time Slot24),
Valid IP address Not involved None
TS27~26,
Compression & TS25(Time Slot25),
TS28~27,
Multiplexing over TS26(Time Slot26),
DISABLE(Disable), DISABLE~0,
Enumeration values TS27(Time Slot27), TS29~28, None
E1/T1 ENABLE(Enable) ENABLE~1
TS30~29, TS31~30
Compression
PPP MUX & TS28(Time Slot28),
Multiplexing over TS29(Time Slot29), Not involved
Interval values 1~512 byte
E1/T1 TS30(Time Slot30),
Compression
PPP MUX & TS31(Time Slot31)
Multiplexing over
Interval values 3~1500 Not involved byte
E1/T1
Compression
PPP MUX &
Multiplexing over
Interval values 1~1000 Not involved ms
E1/T1
Compression &
PPP MUX over
Multiplexing
DISABLE(Disable), DISABLE~0,
E1/T1 Enumeration values None
ENABLE(Enable) ENABLE~1
IP Header
Compression
None Interval values 128~1500 Not involved byte
Compression &
DISABLE(Disable), DISABLE~0,
Multiplexing over Enumeration values None
ENABLE(Enable) ENABLE~1
E1/T1
Compression & INITIAL(INITIAL),
DISABLE(Disable), DISABLE~0,
Multiplexing over Enumeration values STARTING(STARTI None
ENABLE(Enable) ENABLE~1
E1/T1 NG),
INITIAL(INITIAL),
CLOSED(CLOSED)
None Interval values 1~65535
STARTING(STARTI
, Not involved ms
NG), INITIAL~1,
STOPPED(STOPP
CLOSED(CLOSED)
UP(Up), STARTING~2,
None Enumeration values ED), UP~1, DOWN~2 None
,DOWN(Down) CLOSED~3,
CLOSING(CLOSIN INITIAL~1,
STOPPED(STOPP STOPPED~4,
G), STARTING~2,
ED), CLOSING~5,
None Enumeration values STOPPING(STOPP CLOSED~3, None
CLOSING(CLOSIN STOPPING~6,
ING), STOPPED~4,
G), REQSENT~7,
REQSENT(REQSE CLOSING~5,
None Enumeration values STOPPING(STOPP ACKRCVD~8, None
NT), STOPPING~6,
ING), ACKSENT~9,
ACKRCVD(ACKRC REQSENT~7,
REQSENT(REQSE OPENED~10
VD), ACKRCVD~8,
NT),
ACKSENT(ACKSE ACKSENT~9,
ACKRCVD(ACKRC
NT), OPENED~10
VD),
OPENED(OPENED
ACKSENT(ACKSE
)
NT),
OPENED(OPENED
STARTING(STARTI
NG),
CLOSED(CLOSED)
,
INITIAL~1,
STOPPED(STOPP
STARTING~2,
ED),
CLOSED~3,
CLOSING(CLOSIN
STOPPED~4,
G),
CLOSING~5,
None Enumeration values STOPPING(STOPP None
STOPPING~6,
ING),
REQSENT~7,
REQSENT(REQSE
None IP address type Valid ACKRCVD~8,
NT), IP address Not involved None
ACKSENT~9,
ACKRCVD(ACKRC
OPENED~10
None IP address type VD),
Valid IP address Not involved None
ACKSENT(ACKSE
NT),
None IP address type OPENED(OPENED
Valid IP address Not involved None
)
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 128~1500 Not involved byte

DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte/s

None Interval values 0~4294967295 Not involved byte/s

None Interval values 0~4294967295 Not involved None

None IP address type Valid IP address Not involved None

None Interval values 1~1000 Not involved per mill

None Interval values 1~1000 Not involved per mill

E1_COVERBOARD E1_COVERBOARD
None Enumeration values None
(E1 Cover Board) ~3

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved packet

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved byte

None Interval values 0~4294967295 Not involved packet


None Interval values 0~4294967295 Not involved byte

DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support
DiffServ QoS
Interval values 0~63 Not involved None
Support

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None


Enhanced
Transmission QoS Enumeration values IP(IP) IP~1 None
Management BASE_BOARD(Bas
BASE_BOARD~0,
e Board),
None Enumeration values PPP(PPP Link), E1_COVERBOARD None
E1_COVERBOARD
MPGRP(Multi-link ~3
Enhanced (E1 Cover Board) PPP~6, MPGRP~8,
PPP Group),
Transmission QoS Enumeration values ETH~9, None
ETH(Ethernet Port),
Management ETHTRK~10
Enhanced ETHTRK(Ethernet 0~0, 1~1, 2~2, 3~3,
Transmission QoS Interval values Trunk)
0~15 Not
4~4,involved
5~5, 6~6, 7~7, None
Management 0, 1, 2, 3, 4, 5, 6, 7,
8~8, 9~9, 10~10,
Enhanced 8, 9, 10, 11, 12, 13,
11~11, 12~12,
Transmission QoS Enumeration values 14, 15, None
13~13, 14~14,
Management DEFAULTPORT(De
Enhanced 15~15,
fault Port)
Transmission QoS Enumeration values KBPS(Kbit/s) DEFAULTPORT~12
KBPS~0 None
Management 7
Enhanced
Transmission QoS Interval values 32~360000 Not involved None
Management
Enhanced
Transmission QoS Interval values 32~540000 Not involved None
Management
Enhanced
Transmission QoS Interval values 64~400000 Not involved Kbit
Management
Enhanced
Transmission QoS Interval values 64~450000 Not involved Kbit
Management
Enhanced
Transmission QoS Interval values 0~3 Not involved None
Management
Enhanced
Transmission QoS Interval values 1~100 Not involved None
Management
Enhanced
Transmission QoS Interval values 64~360000 Not involved None
Management
Enhanced
Transmission QoS Interval values 64~540000 Not involved None
Management
Enhanced
Transmission QoS Interval values 64~360000 Not involved None
Management
Enhanced
Transmission QoS Interval values 64~540000 Not involved None
Management
None Interval values 64~400000 Not involved Kbit

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None


SINGLE_RATE(Sin
gle Rate), SINGLE_RATE~0,
None Enumeration values None
DUAL_RATE(Dual DUAL_RATE~1
Rate)
None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

None Interval values 0~4294967295 Not involved None

Transport
None Interval values 0~4294967295 Not involved None
Overbooking
Transport
Differentiated Flow Interval values 0~7 Not involved None
Control
Transport
Transport Resource
None
Overload Control Interval values 0~1 Not involved None
Overbooking
Transport
Differentiated Flow Interval values 0~7 Not involved None
Control
Transport Resource
Overload Control
BASE_BOARD(Bas
BASE_BOARD~0,
e Board),
None Enumeration values PPP(PPP Link), E1_COVERBOARD None
E1_COVERBOARD
MPGRP(Multi-link ~3
Enhanced (E1 Cover Board) PPP~6, MPGRP~8,
PPP Group),
Transmission QoS Enumeration values ETH~9, None
ETH(Ethernet Port),
Management ETHTRK~10
Enhanced ETHTRK(Ethernet 0~0, 1~1, 2~2, 3~3,
Transport
Transmission QoS Interval values Trunk)
0~15 Not
4~4,involved
5~5, 6~6, 7~7, None
Overbooking
Management 0, 1, 2, 3, 4, 5, 6, 7,
8~8, 9~9, 10~10,
Transport 8, 9, 10, 11, 12, 13,
Transport 11~11, 12~12,
Differentiated Flow Enumeration values 14, 15, None
Overbooking 13~13, 14~14,
Control DEFAULTPORT(De
Transport 15~15,
Transport
Transport Resource fault Port)
Differentiated Flow Enumeration values OFF(Off), ON(On) DEFAULTPORT~12
OFF~0, ON~1 None
Overload
OverbookingControl
Control 7
Transport
Transport Resource
Transport
Differentiated Flow Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overload
OverbookingControl
Control
Transport
Transport Resource
Transport
Differentiated Flow Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overload
OverbookingControl
Control
Transport
Transport Resource
Transport
Differentiated Flow Interval values 0~1000 Not involved per mill
Overload
OverbookingControl
Control
Transport
Transport Resource
Differentiated Flow
Overload Control Interval values 0~10000 Not involved ms
Control
Transport
Transport Resource DISABLE(Disable), DISABLE~0,
Differentiated Flow
Overload Control Enumeration values None
ENABLE(Enable) ENABLE~1
Control
Enhanced
Transport DISABLE(Disable), DISABLE~0,
Transmission QoS Enumeration values None
Overbooking ENABLE(Enable) ENABLE~1
Management
Transport
Differentiated Flow Interval values 0~6 Not involved None
Control
Transport
Transport Resource
Differentiated Flow
Overload Control Interval values 0~500 Not involved ms
Control
Transport
Differentiated Flow Interval values 0~500 Not involved ms
Control
Enhanced
Transmission QoS Interval values 0~1000000 Not involved Kbit/s
Management
Enhanced
Transmission QoS Interval values 0~1000000 Not involved Kbit/s
Management
Enhanced
Transmission QoS Interval values 0~8192 Not involved packet
Management
None Interval values 0~47 Not involved None

None Interval values 0~7 Not involved None

None Interval values 0~1 Not involved None

None Interval values 0~7 Not involved None

None Interval values 1~34 Not involved None

None IP address type Valid IP address Not involved None


None IP address type Valid IP address Not involved None

None Interval values 1024~65535 Not involved None

None IP address type Valid IP address Not involved None

None IP address type Valid IP address Not involved None

None Interval values 1024~65535 Not involved None

None Interval values 10~59999 Not involved ms

None Interval values 11~60000 Not involved ms

None Interval values 10~59999 Not involved ms

None Interval values 1~99 Not involved None

None Interval values 1~99 Not involved None

None Interval values 1000~60000 Not involved ms

None Interval values 2~254 Not involved None

None Interval values 1~253 Not involved None

DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
ALDER32(ALDER3 ALDER32~0,
None Enumeration values SCTP_TRANSFER None
2), CRC32(CRC32)
_CAUSE_START(S CRC32~1
SCTP_TRANSFER
tart),
DISABLE(Disable), DISABLE~0,
_CAUSE_START~0
None Enumeration values SCTP_TRANSFER None
ENABLE(Enable) ENABLE~1
,
_CAUSE_LINKDO
SCTP_TRANSFER
WN(Link Down),
SCTP_STAT_DOW
None Interval values 1~254 _CAUSE_LINKDO
Not involved None
SCTP_TRANSFER
N(Down), SCTP_STAT_DOW
WN~1,
_CAUSE_PORTDI
SCTP_STAT_CON N~0,
SCTP_TRANSFER
None Enumeration values SABLED(Port
GESTION(Congesti SCTP_STAT_CON
_CAUSE_PORTDI None
Disabled),
on), GESTION~1,
SABLED~2,
SCTP_TRANSFER
SCTP_STAT_UP(U SCTP_STAT_UP~2
SCTP_TRANSFER
None Enumeration values _CAUSE_INIT(Initia
p) None
_CAUSE_INIT~3,
l),
SCTP_TRANSFER
SCTP_TRANSFER
None Composite type None _CAUSE_UNKNO
Not involved None
_CAUSE_UNKNO
WERROR~4,
WERROR(Unknow
SCTP_TRANSFER
None Interval values n
0~34Error), Not involved None
_CAUSE_NORMAL
SCTP_TRANSFER
~5,
_CAUSE_NORMAL
SCTP_TRANSFER
None Interval values (Normal),
0~34 Not involved None
_CAUSE_USERDE
SCTP_TRANSFER
LETE~6
_CAUSE_USERDE
LETE(User Delete)
ACTIVE(Active
Path), ACTIVE~0,
None Enumeration values None
STANDBY(Standby STANDBY~1
Path)
UNBLOCK(Unblock UNBLOCK~0,
None Enumeration values None
), BLOCK(Block) BLOCK~1

None Interval values 10~500 Not involved ms

None Character string 0~47 characters Not involved None

Transport
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overbooking
Transport
Transport
Overbooking Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overbooking
Transport Resource
Transport
Overload Control
Overbooking
Different Transport Interval values 0~100 Not involved %
Transport
Paths Resource
based on
Transport
Overload Control
QoS Grade
Overbooking
Different
Intra-LTE Transport
Load Interval values 0~100 Not involved %
Transport
Paths Resource
based on
Balancing
Transport
Overload Control
QoS Grade
Overbooking
Different
Intra-LTE Transport
Load Interval values 0~100 Not involved %
Transport
Paths Resource
based on
Balancing
Transport
Overload Control
QoS Grade
Overbooking
Different
Intra-LTE Transport
Load Interval values 0~100 Not involved %
Transport
Paths Resource
based on
Balancing
Transport
Overload Control
QoS Grade
Overbooking
Different
Intra-LTE Transport
Load Interval values 0~100 Not involved %
Transport
Paths Resource
based on
Balancing
Transport
Overload Control
QoS Grade
Overbooking
Different
Intra-LTE Transport
Load Interval values 0~100 Not involved %
Transport
Paths Resource
based on
Balancing
Transport
Overload Control
QoS Grade
Overbooking
Different
Intra-LTE Transport
Load Interval values 0~100 Not involved %
Transport
Paths Resource
based on
Balancing
Transport
Overload Control
QoS Grade
Overbooking
Different
Intra-LTE Transport
Load Interval values 0~100 Not involved %
Transport
Paths Resource
based on
Balancing
Overload Control
QoS Grade
Different
Intra-LTETransport
Load Interval values 0~100 Not involved %
Paths based on
Balancing
QoS Grade
Transport
Intra-LTE Load Interval values 0~100 Not involved %
Overbooking
Balancing
Transport
Interval values 0~100 Not involved %
Overbooking
Transport
Interval values 0~100 Not involved %
Overbooking
Transport
Interval values 0~100 Not involved %
Overbooking
Transport
Interval values 0~100 Not involved %
Overbooking
Transport
Interval values 0~100 Not involved %
Overbooking
Transport
Interval values 0~100 Not involved %
Overbooking
Transport
Interval values 0~100 Not involved %
Overbooking
Transport
Interval values 0~100 Not involved %
Overbooking
Transport
Interval values 0~100 Not involved %
Overbooking
Radio/transport
Resource Pre- Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
emption
Radio/transport
Resource Pre- Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
emption
Transport
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overbooking
Transport
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overbooking
Transport
Transport
Overbooking Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overbooking
Transport
Transport
Differentiated Flow
Transport
Overbooking
Control Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overbooking
Transport
Transport
Transport Resource FLOW_CTRL(Flow
Differentiated Flow FLOW_CTRL~0,
Overload
OverbookingControl Control),
Control Enumeration values NON_FLOW_CTRL None
Transport
Transport Dynamic NON_FLOW_CTRL
Transport Resource FLOW_CTRL(Flow ~1
Flow Control
Transport
Differentiated Flow (None Flow Control) FLOW_CTRL~0,
Overload
Different Control
Transport
Overbooking Control),
Control Enumeration values NON_FLOW_CTRL None
Transport
Paths Dynamic
based
Transport on NON_FLOW_CTRL
Transport Resource FLOW_CTRL(Flow ~1
Flow
QoS Control
Transport
Grade
Differentiated Flow (None Flow Control) FLOW_CTRL~0,
Overload
Different Control
Transport
Overbooking Control),
Intra-LTE
Control Load Enumeration values NON_FLOW_CTRL None
Transport
Paths Dynamic
based
Transport on NON_FLOW_CTRL
Balancing
Transport Resource FLOW_CTRL(Flow ~1
Flow
QoS Control
Grade
Differentiated Flow (None Flow Control) FLOW_CTRL~0,
Overload
Different Control
Transport Control),
Intra-LTE
Control Load Enumeration values NON_FLOW_CTRL None
Transport
Paths Dynamic
based on NON_FLOW_CTRL
Balancing
Transport Resource FLOW_CTRL(Flow ~1
Flow
QoS Control
Grade (None Flow Control) FLOW_CTRL~0,
Overload
Different Control
Transport Control),
Intra-LTE Load Enumeration values NON_FLOW_CTRL None
Transport
Paths Dynamic
based on NON_FLOW_CTRL
Balancing ~1
Flow
QoS Control
Grade (None Flow Control)
Intra-LTE
Different Load
Transport
Intra-LTE Load Interval values 0~100 Not involved %
Balancing
Paths based on
Balancing
QoS Grade
Intra-LTE Load
Intra-LTE Interval values 0~100 Not involved %
BalancingLoad
Balancing
Intra-LTE Load
Interval values 0~100 Not involved %
Balancing
Intra-LTE Load
Interval values 0~100 Not involved %
Balancing
Intra-LTE Load
Interval values 0~100 Not involved %
Balancing
Intra-LTE Load
Interval values 0~100 Not involved %
Balancing
Intra-LTE Load
Interval values 0~100 Not involved %
Balancing
Intra-LTE Load
Interval values 0~100 Not involved %
Balancing
Transport Resource
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overload Control
Transport Resource
Enumeration values OFF(Off), ON(On) OFF~0, ON~1 None
Overload Control
Transport Resource
Overload Control
Interval values 0~100 Not involved %
Intra-LTE Load
Transport
Balancing Resource
Overload Control
Interval values 0~100 Not involved %
Intra-LTE Load
Balancing
Transport Resource
Interval values 0~100 Not involved None
Overload Control
Transport Resource
Overload Control
Interval values 0~100 Not involved %
Intra-LTE Load
Transport
Balancing Resource
Overload Control
Interval values 0~100 Not involved %
Intra-LTE Load
Balancing WHITELIST(Whiteli
st), WHITELIST~1,
Integrated Firewall Enumeration values USERDATA(User None
BLACKLIST(Blackli
Data), BLACKLIST~2
st)
SIG(Signaling
None Interval values 0~3
Data), Not involved None
OTHER(Other USERDATA~0,
VLAN Support Data), SIG~1, OTHER~3,
Enumeration values None
(IEEE 802.1p/q) OM_HIGH(High OM_HIGH~4,
Level Maintenance OM_LOW~5
VLAN Support Data),
Interval values 0~63 Not involved None
(IEEE 802.1p/q) OM_LOW(Low
VLAN Support Level Maintenance
Interval values 1~4094
Data) Not involved None
(IEEE 802.1p/q)
VLAN Support
Interval values 0~7 Not involved None
(IEEE 802.1p/q)

None IP address type Valid IP address Not involved None

None Subnet mask type Valid Mask address Not involved None
SINGLEVLAN(Singl
VLAN Support e VLAN), SINGLEVLAN~0,
Enumeration values None
(IEEE 802.1p/q) VLANGROUP(VLA VLANGROUP~1
N Group)
VLAN Support
Interval values 1~4094 Not involved None
(IEEE 802.1p/q)
VLAN Support
Interval values 0~7 Not involved None
(IEEE 802.1p/q)
VLAN Support
Interval values 0~3 Not involved None
(IEEE 802.1p/q)
DISABLE(Disable), DISABLE~0,
None Enumeration values None
ENABLE(Enable) ENABLE~1
Actual Value Recommended Parameter
Default Value Impact TheRelationship
device number
Range Value
of the ALD must be
unique. That is,
0~29 None None ALD
DeviceNo of the
RET and TMA MOs
0~2 characters None None ALD must
None be unique.

The device name of


0~17 characters None None ALD None
an ALD must differ
from other ALDs.
The device names
0~49 characters NULL None ALD
of RET and TMA
must also differ
0~62 0 0 ALD from
Noneother RETs
and TMAs.

4~5,60~254 None None ALD None

0~5 None None ALD None

AISG1.1, AISG2.0,
None None ALD None
3GPP, UNKNOWN

0~8 None None ALD None

0~19 characters None None ALD None

0~127 characters None None ALD None

0~19 characters None None ALD None

SINGLE_RET,
None None ALD None
STMA, MULTI_RET
VendorCode and
SerialNo of an ALD
0~2 characters None None RET 1. When thefrom
RET
must differ
VendorCode
antenna
other ALDs. type andis
SerialNo
1. In a daisy
SINGLE_RET, of an ALD
chain
the
0~17 characters None None RET
must
scenario,differ
number of RET from
other ALDs.
VENDORCODE
subunits is 1.
SINGLE_RET, and SERIALNO
None None RET 2. When the RET
MULTI_RET must be specified.
antenna
Only one type is
physical
2.
portThe
MULTI_RET, controlling
is required enter
for
SINGLE, DUAL None None RET RRU
the or RFUofMO
number thein
a uni-polarization
When the RET
a daisyantenna.
configured
single chainRET
REGULAR, antenna
scenario type is
None None RET subunits. cannot
DAISY_CHAIN SINGLE_RET,
control RET MOs thein
number of RET
regular scenarios.
subunits
The is 1.
controlling
1~8 1 None RET The device number
If
RRUthe RET
or RFU antenna
MObe in
of
typethe ALD must
is MULTI_RET,
a regular
unique. scenario
That is, of
0~29 None None RET enter
cannot the number
control RET
DeviceNo
configured ofRET
the
MOs
RET in other
and TMA MOs
subunits.
regular scenarios
0~2 characters None None RET must
None be unique.
either.

0~17 characters None None RET None


The device name of
an ALD must differ
from other ALDs.
The device names
0~49 characters NULL None RET
of RET and TMA
must also differ
0~62 0 0 RET from
Noneother RETs
and TMAs.

4~5,60~254 None None RET None

0~5 None None RET None

AISG1.1, AISG2.0,
None None RET None
3GPP, UNKNOWN

0~8 None None RET None

0~19 characters None None RET None

0~127 characters None None RET None

0~19 characters None None RET None

SINGLE_RET,
None None RET None
STMA, MULTI_RET

0~29 None None RetDeviceData None

1~8 None None RetDeviceData None

0~359 0 None RetDeviceData None

0~31 characters NULL None RetDeviceData None

0~31 characters NULL None RetDeviceData None

0~359 0 None RetDeviceData None

0~359 0 None RetDeviceData None

0~359 0 None RetDeviceData None

0~359 0 None RetDeviceData None

0~25.5, step:0.1 0 None RetDeviceData None

0~25.5, step:0.1 0 None RetDeviceData None

0~25.5, step:0.1 0 None RetDeviceData None

0~25.5, step:0.1 0 None RetDeviceData None


0~6 characters NULL None RetDeviceData None

-10~30, step:0.1 0 None RetDeviceData None

UNUSED,
0~5 characters NULL None RetDeviceData None
Band800, Band900,
The four frequency
Band1500,
UNUSED, bands supported by
Band1800, UNUSED None RetDeviceData
Band800, the RET antenna
Band1900,Band900, The fourbefrequency
Band1500, cannot repeated.
Band2100,
UNUSED, bands supported by
Band1800,
Band2600 UNUSED None RetDeviceData
Band800, the RET antenna
Band1900,Band900, The fourbefrequency
Band1500, cannot repeated.
Band2100,
UNUSED, bands supported by
Band1800,
Band2600 UNUSED None RetDeviceData
Band800, Band900, the RET antenna
Band1900, The fourbefrequency
Band1500, cannot repeated.
Band2100, bands supported by
Band1800,
Band2600 UNUSED None RetDeviceData
the RET antenna
Band1900,
cannot be repeated.
Band2100,
0~31 characters
Band2600 NULL None RetDeviceData None

0~17 characters NULL None RetDeviceData None

-180~180, step:0.1 None None RetDeviceData None

-180~180, step:0.1 None None RetDeviceData None

0 None None RetPort None

60~254 None None RetPort None

0 None None RetPort None

RET_PORT None None RetPort None


UER_SELF_DEFIN
E, UER_SELF_DEFIN If an ALD needs
According to the
power supply, set RetPort 1.
NoneRetPort MO
The
RET_ONLY_MULTI E ALD type OverCurrAlmClrThr
CORE the ALD power and R0A port of the
supply switch to eshld must beMO of
AntennaPort
ON, OFF OFF RetPort greater
ON. In other cases, an RRUthanMO cannot
set UnderCurrAlmClrTh
For the
RETALD power
(multi-wire be enabled at the
supply switch to reshld.
same time.
1.
10~3500 155 cable mode) only: RetPort
OFF.mA 2.
OverCurrAlmOccTh
UnderCurrAlmClrTh
120
For RET (multi-wire OverCurrAlmClrThr
reshld
reshld must
must be
be
10~3500 185 cable mode) only: RetPort eshld must
greater thanbe
greater than
150 mA smaller than
OverCurrAlmClrThr
UnderCurrAlmOccT
For RET (multi-wire OverCurrAlmOccTh
eshld.
hreshld.
10~3500 60 cable mode) only: RetPort reshld.
2.
UnderCurrAlmOccT
15 mA
For RET (multi-wire UnderCurrAlmClrTh
hreshld must be
10~3500 40 cable mode) only: RetPort reshld must
smaller thanbe
10 mA smaller
Value than ON~0,
range:
UnderCurrAlmClrTh
OverCurrAlmClrThr
OFF~1
reshld.
0~3500 None None RetPort None this
eshld.
When
parameter is 0, the
power switch is
ON, OFF None None RetPort
turned on.
When this
parameter is 1, the
power switch is
turned off.
0~29 None None RETSubUnit None

1~8 None None RETSubUnit None


AVAILABLE,
UNAVAILABLE, None None RETSubUnit None
BREAKLINK In the non-MIMO-
1.When
mutual-aid the subrack
-10~30, step:0.1 None None RETSubUnit None
number
scenarios, the
of the port
is 255, the port
connecting portsis1
not
and connected.
2 must be
0~11 None None RETSubUnit None
2. In the antenna
non-
different
In the non-MIMO-
MIMO-mutual-aid
ports on the same
mutual-aid
scenarios,
0~62 0 0 RETSubUnit RRU.In
scenarios, thetheMIMO-
the
connecting
mutual-aid
In the non-MIMO- ports 1
connecting
and 2 mustthe ports
be 1
scenarios,
mutual-aid
and 2 must be
4~5,60~255 255 None RETSubUnit different
connecting
scenarios, antenna
ports 1
the
different
ports antenna
In
andthe2on
connecting
ports
1.When on
theports
non-MIMO-
must thebe
the
same1
same
subrack
RRU. In
mutual-aid
different
and 2 mustthe MIMO-
antenna
be
0~5 0 None RETSubUnit RRU.In
number
mutual-aid
scenarios, the
of MIMO-
the
the port
ports
255,onthe
different
mutual-aid
is different
antenna
port is
R0A, R0B, R0C, scenarios,
RRUs.
ports on thethe
connecting ports
same1
scenarios,
not
and connected.
connecting
2 must the
ports
be 1
R0D, R0E, R0F, R0A None RETSubUnit RRU.In
connecting
2.In the the MIMO-
ports
non-MIMO- 1
R0G, R0H and 2 can
different
mutual-aid
In the be
antenna
non-MIMO-
and 2 can
mutual-aid
different
ports be
on antenna
thethe
same
scenarios,
mutual-aid
different
scenarios, antenna
the
0~62 0 0 RETSubUnit ports
RRU.In on
connecting different
the MIMO-
ports
scenarios,
ports on
connecting
RRUs.
mutual-aid
In the non-MIMO-ports 1
the
different 1
and
RRUs.
and 2
2 can
connecting
must beports
be 1
scenarios,
mutual-aid
different
and 2 must the
antenna
be
4~5,60~255 255 None RETSubUnit different
connecting
scenarios, antenna
ports 1
the
ports on
different
ports different
antenna
and 2on
can
connecting
RRUs.
ports on
the
be
the
same1
ports
same
RRU.In
different
and the
2 must MIMO-
antenna
be
0~5 0 None RETSubUnit RRU.In
mutual-aid the MIMO-
ports on antenna
different
mutual-aid different
R0A, R0B, R0C, scenarios,
RRUs.
ports on thethe
same
scenarios,
connecting the
ports 1
R0D, R0E, R0F, R0B None RETSubUnit RRU.In
connecting the MIMO-
ports 1
R0G, R0H and 2 can
mutual-aid be
and 2 can
different be
antenna
scenarios,
different the
antenna
-10~30, step:0.1 0 None RETSubUnit ports
None on different
connecting ports 1
ports
RRUs. on different
and
RRUs. 2 can be
0~1, step:0.1 5 5 RETSubUnit different
None antenna
ports on different
RRUs.
1~2 None None TMA Nonedevice number
The
of the ALD must be
unique. That is,
0~29 None None TMA
DeviceNo of the
RET and TMA MOs
0~2 characters None None TMA must
None be unique.

The device name of


0~17 characters None None TMA None
an ALD must differ
from other ALDs.
The device names
0~49 characters NULL None TMA
of RET and TMA
must also differ
0~62 0 0 TMA from
Noneother RETs
and TMAs.

4~5,60~254 None None TMA None

0~5 None None TMA None


AISG1.1, AISG2.0,
None None TMA None
3GPP, UNKNOWN

0~8 None None TMA None

0~19 characters None None TMA None

0~127 characters None None TMA None

0~19 characters None None TMA None

SINGLE_RET,
None None TMA None
STMA, MULTI_RET

0~29 None None TMADeviceData None

1~2 None None TMADeviceData None

0~359 0 None TMADeviceData None

0~31 characters NULL None TMADeviceData None

0~359 0 None TMADeviceData None

0~359 0 None TMADeviceData None

0~359 0 None TMADeviceData None

0~359 0 None TMADeviceData None

0~25.5, step:0.1 0 None TMADeviceData None

0~25.5, step:0.1 0 None TMADeviceData None

0~25.5, step:0.1 0 None TMADeviceData None

0~25.5, step:0.1 0 None TMADeviceData None

0~6 characters NULL None TMADeviceData None

-10~30, step:0.1 0 None TMADeviceData None

UNUSED,
0~5 characters NULL None TMADeviceData None
Band800, Band900,
The four frequency
Band1500,
UNUSED, bands supported by
Band1800, UNUSED None TMADeviceData
Band800, the TMA cannot be
Band1900,Band900, The four frequency
Band1500, repeated.
Band2100, bands supported by
Band1800,
Band2600 UNUSED None TMADeviceData
the TMA cannot be
Band1900,
repeated.
Band2100,
Band2600
UNUSED,
Band800, Band900,
The four frequency
Band1500,
UNUSED, bands supported by
Band1800, UNUSED None TMADeviceData
Band800, the TMA cannot be
Band1900,Band900, The four frequency
Band1500, repeated.
Band2100, bands supported by
Band1800,
Band2600 UNUSED None TMADeviceData
the TMA cannot be
Band1900,
repeated.
Band2100,
0~31 characters
Band2600 NULL None TMADeviceData None

0~17 characters NULL None TMADeviceData None

0~31 characters NULL None TMADeviceData None

0~63.75, step:0.25 0 None TMADeviceData None


UNSUPPORT,
SUPPORT_PASSB
Y, UNSUPPORT None TMADeviceData None
SUPPORT_VSWR, TmaRxMaxFreBand
VSWR/PASSBY
0~6553500, must not be less
0 None TMADeviceData
step:100 than
TmaTxMaxFreBand
TmaRxMinFreBand.
0~6553500, must not be less
0 None TMADeviceData
step:100 than
TmaRxMinFreBand
TmaTxMinFreBand.
must not be more
0~6553500,
0 None TMADeviceData than
step:100 TmaTxMinFreBand
TmaRxMaxFreBand
must
. not be more
0~6553500,
0 None TMADeviceData than
step:100
TmaTxMaxFreBand
.
0~63.75, step:0.25 None None TMADeviceData None

0~63.75, step:0.25 None None TMADeviceData None

0~29 None None TMASubUnit None

1~2 None None TMASubUnit None

0~11 None None TMASubUnit None

0~63.75, step:0.25 None None TMASubUnit None

NORMAL, BYPASS None None TMASubUnit None


AVAILABLE,
UNAVAILABLE, None None TMASubUnit None
BREAKLINK
R0A, R0B, R0C,
R0D, R0E, R0F, None None TMASubUnit None
R0G, R0H
0~62 None 0 TMASubUnit None

0~5 None None TMASubUnit None

4~5,60~254 None None TMASubUnit None


0~63.75, step:0.25 0 48 TMASubUnit None
1. When Mode in
the BBP MO is set
NORMAL, BYPASS NORMAL NORMAL TMASubUnit to TDD_ENHANCE,
None
the RRUCHAIN MO
does not support
0~7 0 0 BBP None
the ring topology,
namely that
TopoType cannot
0~1 0 0 BBP None
be RING in this
Avail_0, Avail_1, case.
Avail_20,
0~5 Avail_21, None 1,2,3 BBP When
None Mode in the
Avail_500, BBP MO is set to
Avail_501, TDD, the
Locked, Unlocked,
Avail_504, Unlocked Unlocked BBP None
RRUCHAIN MO
Shutingdown
Avail_508, does not support
RAT_FDD,
Avail_509, the hot backup ring
RAT_TDD,
Avail_520,
Alarm_0, Alarm_1, None None BBP
topology. That is,
TDD_ENHANCE
Avail_521,
Alarm_2, Alarm_3, when TopoType is
Avail_524,
Alarm_4, Alarm_5, set to RING,
LBBPb, LBBPc None None BBP None
Avail_528,
Alarm_6, Alarm_7, BackupMode
Avail_529,
Alarm_8, Alarm_9, cannot be HOT.
Avail_800,
Alarm_10, None None BBP None
2. When Mode in
Avail_801,
Alarm_11, the BBP MO is set
Avail_820,
Alarm_12, to TDD or
Enabled,
Alarm_13,Disabled
Avail_821, None None BBP None
TDD_ENHANCE,
Avail_c10,
Alarm_14, the RRU MO does
Avail_c11,
Alarm_15 not support a multi-
None None BBP None
Avail_c12, level chain, namely
Avail_c13, that InsertPos in the
Avail_c14,
0~2047 characters None None BBP None MO cannot be
RRU
Avail_c30, greater than 0 in
Avail_c31, this case.
0~31 characters
Avail_c32, None None BBP None
Avail_c33,
Avail_c34,
0~31 characters None None BBP None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None BBP None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None BBP None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None BBP None
Avail_d29
0~19 characters None None BBP None
LMPT, LBBP, FAN,
UPEU, UTRP, None None BBP None
USCU, UEIU
0~4294967295 None None BBP None

CPU, DSP None None BBP None


-
2147483648~2147 None None BBP None
483647
-
2147483648~2147 None None BBP None
483647
0~255 characters None None BBP None
Master, NDD, NCD,
NDC, NEC, EUL, None None BBP None
EDL
CABINET,
SUBRACK,
None None BBP None
BOARD,
SUBBOARD, SFP
0~63 characters None None BBP None

0~63 characters None None BBP None

0~63 characters None None BBP None

0~63 characters None None BBP None

1~39 characters None None BBP None

Normal, Fault,
None None BBP None
Timeout, NULL

0~65535 None None BBP None

0~65535 None None BBP None


Avail_0, Avail_1,
Avail_20,
0~7 Avail_21, 0 0 MPT None
Avail_500,
Avail_501,
Avail_504,
0~1 0 0 MPT None
Avail_508,
Avail_509,
6~7
Avail_520,
Alarm_0, Alarm_1, None 7 MPT None
Avail_521,
Alarm_2, Alarm_3,
Avail_524,
Alarm_4, Alarm_5,
Active, Standby None None MPT None
Avail_528,
Alarm_6, Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
Avail_800,
Alarm_10, None None MPT None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None MPT None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None MPT None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None MPT None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None MPT None
Avail_c33,
Avail_c34,
0~31 characters None None MPT None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None MPT None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None MPT None
Avail_d21,
Avail_d24,
Avail_d28,
Avail_d29
0~23 characters None None MPT None

0~19 characters None None MPT None


LMPT, LBBP, FAN,
UPEU, UTRP, None None MPT None
USCU, UEIU
0~4294967295 None None MPT None

CPU, DSP None None MPT None


-
2147483648~2147 None None MPT None
483647
-
2147483648~2147 None None MPT None
483647
0~255 characters None None MPT None
Master, NDD, NCD,
NDC, NEC, EUL, None None MPT None
EDL
CABINET,
SUBRACK,
None None MPT None
BOARD,
SUBBOARD, SFP
0~63 characters None None MPT None

0~63 characters None None MPT None

0~63 characters None None MPT None

0~63 characters None None MPT None

1~39 characters None None MPT None

Normal, Fault,
None None MPT None
Timeout, NULL

0~65535 None None MPT None

0~65535 None None MPT None

0~7 0 0 TRP None

0~1 0 0 TRP None

0~5
Alarm_0, Alarm_1, None 5 TRP None
Alarm_2, Alarm_3,
Alarm_4,
UIEB Alarm_5, None None TRP None
Alarm_6, Alarm_7,
Alarm_8, Alarm_9,
Alarm_10, None None TRP None
Alarm_11,
Alarm_12,
Alarm_13,
Alarm_14,
Alarm_15
Avail_520,
Avail_521,
Avail_524,
Avail_528,
Avail_529,
Avail_800,
Avail_801,
Avail_820,
Enabled,
Avail_821,Disabled None None TRP None
Avail_c10,
Avail_c11,
None None TRP None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None TRP None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None TRP None
Avail_c33,
Avail_c34,
0~31 characters None None TRP None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None TRP None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None TRP None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None TRP None
Avail_d29
0~19 characters None None TRP None
LMPT, LBBP, FAN,
UPEU, UTRP, None None TRP None
USCU, UEIU
0~4294967295 None None TRP None

CPU, DSP None None TRP None


-
2147483648~2147 None None TRP None
483647
-
2147483648~2147 None None TRP None
483647
0~255 characters None None TRP None
Master, NDD, NCD,
NDC, NEC, EUL, None None TRP None
EDL
CABINET,
SUBRACK,
None None TRP None
BOARD,
SUBBOARD, SFP
0~63 characters None None TRP None

0~63 characters None None TRP None

0~63 characters None None TRP None

0~63 characters None None TRP None

1~39 characters None None TRP None

Normal, Fault,
None None TRP None
Timeout, NULL
0~65535 None None TRP None
Avail_0, Avail_1,
Avail_20,
0~65535 Avail_21, None None TRP None
Avail_500,
Avail_501,
Avail_504,
0~7 0 0 USCU None
Avail_508,
Avail_509,
0~1
Avail_520,
Alarm_0, Alarm_1, 0 0 USCU None
Avail_521,
Alarm_2, Alarm_3,
Avail_524,
Alarm_4, Alarm_5,
0~5 None 4 USCU None
Avail_528,
Alarm_6, Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
Avail_800,
Alarm_10, None None USCU None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None USCU None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None USCU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None USCU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None USCU None
Avail_c33,
Avail_c34,
0~31 characters None None USCU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None USCU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None USCU None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None USCU None
Avail_d29
0~19 characters None None USCU None
LMPT, LBBP, FAN,
UPEU, UTRP, None None USCU None
USCU, UEIU
0~4294967295 None None USCU None

CPU, DSP None None USCU None


-
2147483648~2147 None None USCU None
483647
-
2147483648~2147 None None USCU None
483647
0~255 characters None None USCU None
Master, NDD, NCD,
NDC, NEC, EUL, None None USCU None
EDL
CABINET,
SUBRACK,
None None USCU None
BOARD,
SUBBOARD, SFP
0~63 characters None None USCU None

0~63 characters None None USCU None

0~63 characters None None USCU None

0~63 characters None None USCU None

1~39 characters None None USCU None

Normal, Fault,
None None USCU None
Timeout, NULL

0~65535 None None USCU None


Avail_0, Avail_1,
Avail_20,
0~65535 Avail_21, None None USCU None
Avail_500,
Avail_501,
Avail_504,
0~7 0 0 BbuFan None
Avail_508,
Avail_509,
0~1
Avail_520,
Alarm_0, Alarm_1, 0 0 BbuFan None
Avail_521,
Alarm_2, Alarm_3,
Avail_524,
Alarm_4, Alarm_5,16 None 16 BbuFan None
Avail_528,
Alarm_6, Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
Avail_800,
Alarm_10, None None BbuFan None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None BbuFan None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None BbuFan None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None BbuFan None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None BbuFan None
Avail_c33,
Avail_c34,
0~31 characters None None BbuFan None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None BbuFan None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None BbuFan None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None BbuFan None
Avail_d29
0~19 characters None None BbuFan None
LMPT, LBBP, FAN,
UPEU, UTRP, None None BbuFan None
USCU, UEIU
0~4294967295 None None BbuFan None
CPU, DSP None None BbuFan None
-
2147483648~2147 None None BbuFan None
483647
-
2147483648~2147 None None BbuFan None
483647
0~255 characters None None BbuFan None
Master, NDD, NCD,
NDC, NEC, EUL, None None BbuFan None
EDL
CABINET,
SUBRACK,
None None BbuFan None
BOARD,
SUBBOARD, SFP
0~63 characters None None BbuFan None

0~63 characters None None BbuFan None

0~63 characters None None BbuFan None

0~63 characters None None BbuFan None

1~39 characters None None BbuFan None

Normal, Fault,
None None BbuFan None
Timeout, NULL

0~65535 None None BbuFan None


Avail_0, Avail_1,
Avail_20,
0~65535 Avail_21, None None BbuFan None
Avail_500,
Avail_501,
Avail_504,
0~7 0 0 EIU None
Avail_508,
Avail_509,
0~1
Avail_520,
Alarm_0, Alarm_1, 0 0 EIU None
Avail_521,
Alarm_2, Alarm_3,
Avail_524,
Alarm_4,
18~19 Alarm_5, None 18 EIU None
Avail_528,
Alarm_6, Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
Avail_800,
Alarm_10, None None EIU None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None EIU None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None EIU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None EIU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None EIU None
Avail_c33,
Avail_c34,
0~31 characters None None EIU None
Avail_d00,
Avail_d01,
Avail_d04,
Avail_d08,
Avail_d09,
Avail_d20,
Avail_d21,
Avail_d24,
0~259 characters None None EIU None

0~11 characters None None EIU None

0~23 characters None None EIU None

0~19 characters None None EIU None


LMPT, LBBP, FAN,
UPEU, UTRP, None None EIU None
USCU, UEIU
0~4294967295 None None EIU None

CPU, DSP None None EIU None


-
2147483648~2147 None None EIU None
483647
-
2147483648~2147 None None EIU None
483647
0~255 characters None None EIU None
Master, NDD, NCD,
NDC, NEC, EUL, None None EIU None
EDL
CABINET,
SUBRACK,
None None EIU None
BOARD,
SUBBOARD, SFP
0~63 characters None None EIU None

0~63 characters None None EIU None

0~63 characters None None EIU None

0~63 characters None None EIU None

Before modifying
1~39 characters None None EIU None
this parameter,
The
ensurestringthatofallName
cells
Normal, Fault, of
of the
the eNodeB
eNodeB are
None None EIU None be null
cannot
Timeout, NULL deactivated. If there
characters
are neighboring or
Before
contain modifying
any of the
0~65535 None None EIU relationships
None
this parameter,
following
between some cells
ensure
characters: that all cells
of
of an eNodeB,
the eNodeB all
0~65535 None None EIU question
None
neighboring marksare (?),
deactivated.
colons (:), If there
right
relationships
are neighboring with all
angle
cells ofbrackets
the eNodeB(>),
0~1048575 0 None eNodeB relationships
left angle brackets
must
between be removed.
some(*), cells
(<),
Afterasterisks
an eNodeB ID
of an
slashes eNodeB,
(/), the CGIall
1~64 characters DBS3900 LTE None eNodeB is modified,
neighboring
backslashes
of all serving (\), cells
relationships
bars (|), double with all
of the
cells ofeNodeB
the eNodeBmust
000~999 460 None eNodeB quotation
be modified marks ("),
must
commas be removed.
(,),
manually.
After The
an eNodeB
semicolons
eNodeB must (;),be ID
is modified,
equal signs the (=), CGI
reset
of all before
serving the
cells
single
change quotation
in this must
of the eNodeB
marks ('), three
parameter
be modified takesplus
signs
effect. (+++), two or
manually.
more blanks, Theand
eNodeB
two or more bemust
eNodeB are
RESTHRESHOLD
Cell_Call_Drop_Rat
deactivated.
ranges from 0 If there
to
e.
are neighboring
1000. When
2. The value
relationships
KPITYPE is set rangeto
of
between some cells
Transmission_Delay
FLTTHRESHOLD
,oftheanvalue
eNodeB, of all
depends
neighboring
RESTHRESHOLD on the
value
ranges offrom
relationships KPITYPE. 0with
ms all
to
00~99,000~999 20 None eNodeB When
cells of
5000 KPITYPE
ms. theWheneNodeB is
DBS3900_LTE, set
must
KPITYPEtobe removed.
is set to
BTS3900_LTE, DBS3900_LTE(DB Transmission_Pack
After a mobile
Transmission_Jitter,
None eNodeB None
et_Loss_Rate,
network
the valuecode of isthe
BTS3900A_LTE, S3900 LTE)
BTS3900L_LTE value
modified, of the CGI of
RESTHRESHOLD
1. PowerOffTime
FLTTHRESHOLD
ON, OFF OFF None eNodeB all
ranges
None serving from cells 0 ms of to
must
ranges range
from from
0 to
the eNodeB
1000 ms. When must
22:00
1000. to When
05:00 of
bePowerOnTime
modified
KPITYPE
1. is set to
the
KPITYPEnext day.
is from
set to
22:00:00~5:00:00 00:00:00 None eNodeB manually.
Packet_Loss_Rate,
must range The
2. PowerOnTime
Transmission_Delay
system
the
23:00 value must
to an of
06:00 beof
must
,the
thenextbe
value ofhour
reset before
RESTHRESHOLD the
23:00:00~6:00:00 06:00:00 None eNodeB later thanday.
FLTTHRESHOLD
When KPITYPE is modified
ranges MNC
from
2. PowerOnTime 0 to
PowerOffTime.
ranges
This from 0 ms is to
set to takesparameter
1000.
must effect.
be When
an hour
-180~180, step:1e- 5000
valid
KPITYPE ms.
only When
when
later than is set to
0 Transmission_Pack
None eNodeB
6 When KPITYPE KPITYPE
GCDF is set
is set to to
et_Loss_Rate or is Cell_RRC_Connect
PowerOffTime.
This
set to DEG.parameter
Transmission_Jitter,
_Succ_Rate, the
is
Cell_Call_Drop_Rat valid only when
-90~90, step:1e-6 0 Transmission_Pack
None eNodeB the value
value of of
e, the GCDF is set to
et_Loss_Rate FLTTHRESHOLD
recommended or RESTHRESHOLD
DEG.
Cell_Call_Drop_Rat ranges
ranges from from 0 0% mstoto
0~20 characters None value
None for eNodeB None ms.
e, the 1000
100%. When When
FLTTHRESHOLD is
recommended KPITYPE is
KPITYPE is setset to to
Default, Normal, 10.
value Packet_Loss_Rate,
Demo, Protected, None None for
When KPITYPE is eNodeB Cell_SAEB_Setup_
None
the value of the
Emergency RESTHRESHOLD
set to Succ_Rate,
is 5. FLTTHRESHOLD
value of
Transmission_Delay The
1. LONGITUDE
If GCDF
Poweroff, Normal None When KPITYPE is ranges
RESTHRESHOLD fromis0 set toto
,Nonethe recommended eNodeB None
and
SEC, LATITUDE
this
set to 1000.from
ranges When 0% to
value for parameters
parameter are
Transmission_Delay KPITYPE
100%. When ismustset to be
FLTTHRESHOLD is 1. If GCDF
valid only in
specified isthe
when setthis
to
0~128 characters
Transmission_Pack None None
,300.
the recommended eNodeB None
Cell_RRC_Connect
KPITYPE isisset to
SEC,
parameter
format this
of set to
et_Loss_Rate, value _Succ_Rate, the
When for KPITYPE is Cell_Call_Drop_Rat
parameter
DEG. The must be
dd:mm:ss.ssss,dd
Transmission_Delay RESTHRESHOLD value
e, the of
value of
DEG, SEC DEG set
None to eNodeB specified
LONGITUDESECF
indicates in
thethe
, is 200. FLTTHRESHOLD
RESTHRESHOLD
Transmission_Jitter, format
ORMAT
degree of and
ranging
Transmission_Jitter, When KPITYPE is ranges from
ranges from 0% to
0% to
the
When recommended
KPITYPE is ddd:mm:ss.ssss,
LONGITUDESECF
from 90 to 90, mm
Packet_Loss_Rate,
0~16 None set
None to eNodeB 100%.
100%. When
When
value
set to for ddd
ORMAT indicates
indicates parameters
the the
minute
Cell_RRC_Connect Transmission_Jitter, KPITYPE
KPITYPE is
is setset to
to
FLTTHRESHOLD
Transmission_Pack is degree
are valid
ranging ranging
only
from 0 when
to
_Succ_Rate, the recommended Cell_SAEB_Setup_
Intra-
100. from
this 180
parameter to 180,
0~16
Cell_SAEB_Setup_ None et_Loss_Rate,
None for
value eNodeB 59, and
Succ_Rate, ss.ssss
Frequency_HO_Su theis
When KPITYPE is
Transmission_Delay mm
set indicates
to
indicates SEC. the the
Succ_Rate, RESTHRESHOLD value of the value
cc_Rate,
set to
,is 50. minute
second ranging
ranging from
Cell_Call_Drop_Rat FLTTHRESHOLD
of
None Packet_Loss_Rate,
None
Transmission_Jitter, KPIALARM 0 to
None
from 59,
0 to and ss.ssss
59.9999.
e, Intra- When KPITYPE is ranges
RESTHRESHOLD from 0% to
the
or recommended indicates
2. When the is
GCDF
Frequency_HO_Su set to for 100%. When
ranges from 0% to
value
Packet_Loss_Rate, second
SEC,This ranging
paramter
cc_Rate,
ON, OFF Inter- None Packet_Loss_Rate,
OFF KPIALARM KPITYPE
100%. When
None0 to 59.9999.is set to
FLTTHRESHOLD
the recommended is from
is not NULL.
Frequency_HO_Su the recommended Cell_Call_Drop_Rat
KPITYPE is set to
5.
value of this 2. When GCDF is
cc_Rate, LTE- value for e, the value of
Inter-
When
parameterKPITYPE
is 360.is SEC,This paramter
0~4294967295
CDMA_Handover_ None RESTHRESHOLD KPIALARM FLTTHRESHOLD
Frequency_HO_Su
set
When to KPITYPE is is not NULL.
Succ_Rate, LTE- is 1. ranges from
cc_Rate, the0% value to
Cell_RRC_Connect
set to KPITYPE is
WCDMA_Handover When 100%. When
of
0~4294967295 None _Succ_Rate
Cell_RRC_Connect or KPIALARM
_Succ_Rate, LTE- set to KPITYPE
RESTHRESHOLD is set to
Cell_SAEB_Setup_
_Succ_Rate,
GERAN_Handover Cell_RRC_Connect Intra-
ranges from 0% to
Succ_Rate,
Cell_SAEB_Setup_the
_Succ_Rate
0~4294967295 100 _Succ_Rate or KPIALARM Frequency_HO_Su
100%.
None When
recommended
Succ_Rate,
Cell_SAEB_Setup_ cc_Rate, the
KPITYPE is set valueto
value for
Cell_Call_Drop_Rat
15minutes, Succ_Rate, the is of
LTE-
FLTTHRESHOLD
e, Intra-
30minutes, 60minutes 60minutes
recommended KPIALARM FLTTHRESHOLD
None
CDMA_Handover_
90.
Frequency_HO_Su
60minutes, 1day value for ranges
Succ_Rate, from the 0% to
When
cc_Rate, KPITYPE
Inter- is
RESTHRESHOLD 100%.
value of When
0~23 0 set
None to Intra-
Frequency_HO_Su KPIALARM None
is 95. KPITYPE is set to
RESTHRESHOLD
Frequency_HO_Su
cc_Rate, LTE-
When KPITYPE Inter- from 0% to
cc_Rate or Inter-is
CDMA_Handover_
ranges
1~3 1 set
1 to Intra- KPIALARM Frequency_HO_Su
100%.
None When
Frequency_HO_Su
Succ_Rate, LTE-
Frequency_HO_Su cc_Rate,
KPITYPEthe is set valueto
cc_Rate, the
WCDMA_Handover
cc_Rate or Inter- of
LTE-
recommended
_Succ_Rate, or
0~7 0 0
Frequency_HO_Su PEU FLTTHRESHOLD
None
WCDMA_Handover
value
LTE- for
cc_Rate, the ranges from 0%
_Succ_Rate, theto
FLTTHRESHOLD
GERAN_Handover is
recommended 100%.
value ofWhen
85.
_Succ_Rate, the
value for KPITYPE
RESTHRESHOLD is set to
When KPITYPE is
recommended
RESTHRESHOLD LTE-
ranges from 0% to
set
valueto LTE-
is 90. of this
CDMA_Handover_
CDMA_Handover_
100%. When
parameter
When is 100.is
KPITYPE Succ_Rate,
KPITYPE is theset to
Succ_Rate, LTE-
set to LTE- value
LTE- of
WCDMA_Handover
CDMA_Handover_ FLTTHRESHOLD
GERAN_Handover
Avail_0, Avail_1,
Avail_20, Avail_21,
Avail_500,
Avail_501,
Avail_504,
Avail_508,
Avail_509,
0~1
Avail_520,
Alarm_0, Alarm_1, 0 0 PEU None
Avail_521,
Alarm_2, Alarm_3,
Avail_524,
Alarm_4,
18~19 Alarm_5, None 19 PEU None
Avail_528,
Alarm_6, Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
Avail_800,
Alarm_10, None None PEU None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None PEU None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None PEU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None PEU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None PEU None
Avail_c33,
Avail_c34,
0~31 characters None None PEU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None PEU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None PEU None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None PEU None
Avail_d29
0~19 characters None None PEU None
LMPT, LBBP, FAN,
UPEU, UTRP, None None PEU None
USCU, UEIU
0~4294967295 None None PEU None

CPU, DSP None None PEU None


-
2147483648~2147 None None PEU None
483647
-
2147483648~2147 None None PEU None
483647
0~255 characters None None PEU None
Master, NDD, NCD,
NDC, NEC, EUL, None None PEU None
EDL
CABINET,
SUBRACK,
None None PEU None
BOARD,
SUBBOARD, SFP
0~63 characters None None PEU None

0~63 characters None None PEU None

0~63 characters None None PEU None


0~63 characters None None PEU None

1~39 characters None None PEU None

Normal, Fault,
None None PEU None
Timeout, NULL

0~65535 None None PEU None

0~65535 None None PEU None

0~62 0 0 AntennaPort None

4~5,60~254 None None AntennaPort None

0~5 None None AntennaPort None


UER_SELF_DEFIN
R0A,
E, R0B, R0C,
R0D, R0E, R0F,
TMA12DB_ONLY_ None None AntennaPort None
R0G, R0H
NON_AISG,
TMA24DB_ONLY_ UER_SELF_DEFIN If an ALD needs
According to the
power supply, set AntennaPort 1.
NoneRetPort MO
The
NON_AISG, E ALD
For type
12 dB non- OverCurrAlmClrThr
RET_ONLY_COAXI the ALD power and R0A port of the
AISG TMA:
supply switch 150
to eshld must beMO of
AntennaPort
AL,
ON, OFF OFF mA; For 24 dB non- AntennaPort greater
TMA12DB_AISG, ON. In other
For 12TMA:
dB non-cases, an RRUthanMO cannot
AISG
set the ALD 280
power UnderCurrAlmClrTh
be enabled at the
TMA24DB_AISG AISG
mA; TMA:
For RET 170 reshld.
10~3500 155 supply
mA; For switch
24 dBtonon- AntennaPort same time.
1.
(coaxial)
OFF. only: 120 2.
OverCurrAlmOccTh
UnderCurrAlmClrTh
AISG
For
mA;12 TMA:
For dB 310TMA
12non-
dB OverCurrAlmClrThr
reshld
reshld must
must be
be
mA;
AISG For RET
and RET or 40
TMA: 12 mA;
dB eshld must
10~3500 185
(coaxial)
AntennaPort greater thanbe
greater than
For
TMA24 dBonly:
(AISG) non- 150
only: smaller than
OverCurrAlmClrThr
For
mA; 12
For dB
12non-
dB UnderCurrAlmOccT
AISG
400 mA TMA: 60 TMA
mA; OverCurrAlmOccTh
eshld.
AISG
and TMA:
RET or 30
12 mA;
dB hreshld.
10~3500 60 For RET (coaxial) AntennaPort reshld.
For
TMA24 2.
only: 33dB
(AISG)
mA;non-
only:
For 12 UnderCurrAlmOccT
AISG TMA: UnderCurrAlmClrTh
450TMA
dB mA and40 RETmA;or hreshld must be
10~3500 40 For RET (coaxial) AntennaPort reshld must
smaller thanbe
12 dB TMA (AISG)
only: smaller than
only: 25
40 mA;
mA For 12 UnderCurrAlmClrTh
dB TMA and RET or OverCurrAlmClrThr
reshld.
0~1000 0 None
12 dB TMA (AISG) AntennaPort None
eshld.
only: 30 mA
0~50 0 None AntennaPort None

0~50 0 None AntennaPort None

0~3500 None None AntennaPort None

ON, OFF None None AntennaPort None

0~62 0 0 CpriPort None

0~1,4~5,60~254 None None CpriPort None

0~5 None None CpriPort None


1. PS in an RRU
MO must be unique
and consecutive on
0~5 None None CpriPort None
an RRU chain/ring.
PS in an RFU MO
0.614, 1.25, 2.5, must
None None CpriPort None be set to 0.
4.9, NULL If TT and BM in an
1. An RRU with
RRUCHAIN MO,
BLOCK, UNBLOCK None None CpriPort 8T8R
None (eight
where the RRU TX or
channels
You can
RFU MOspecifyand eight
is the
RX channels)
VswrAlmThrhld
configured, are set only
Locked, Unlocked, supports onlyHOT the
Unlocked Unlocked RE None
1.
when
to The
RING number
the and of
Shutingdown chain or load
AntennaPort
VswrAlmSwitch
respectively, MOs
PS isin
sharing
is
setequal
the to
RRU topology.
ON.toorthe RFU
ON, OFF ON ON RE 1. The
Therefore,
larger value
value of to
if set
If the
MO must be
ALMPROCTHRHL
RXNUM
between
VswrAlmSwitch
0. is set tois8,
RXNUM
D
TT
and
set must
inTXNUM
thebesame greater
in the
1.5~10, step:0.1 25 25 RE If
1
than20to
TT
RRUCHAIN
inOFF,
that
an
of MO
RRU
RRUCHAIN
2. MO.
VswrAlmThrhld For MO, is
1. If Mode
ALMTHRHLD.
must
example,
invalid. be setaninto the
RRU
where
ALMPROCTHRHL the RRU or
1.5~3, step:0.1 20 20 RE BBP
2 25 one
CHAIN
with MOorTX is set to
RFU
D MO
must be or is greater
RAT_TDD
BALANCE.
channel the and
configured,
than
TDD_ENHANCE,
An RRU with
istwoset to
8T8R
RX
BALANCE,
RCN channels
ALMTHRHLD. and PS PS arein
must
0~3 None None RE RS
can in
connecteduse theonlyRRUto MO
ports
the
be RRU
unique orintoRFU
an
must
0 and
antenna be
1. set
Therefore,
ports R0A
MO
RRU must
or RFU be set MO. to
LO_TD.
if0.RXNUM
and R0B. Ifisposition
set to
the
0~249 None None RE That
2. If is, the
RSvalue
in the
the RRU
8, HPN
larger
2. RCN in
and
of
MO anisRRU not orPS
set RFU
to
CpriPort
between
must be MO
RXNUM
unique used in
in the
LO_TD, topology
its value
TRUNK TRUNK None RE by
None
and
an the
RRU RRUCHAIN
TXNUM or is
RFUMO.
must
cannot bebe unique.
greater
MO
Thatmust
changed, is, the be
the set to
position
than
0 or
number 2.
1. of
LO_TD, LO, CL, of an RRU or RFU
None None RE 3.
2. RS innumber
The
AntennaPort the RRU MOs of
GL, UL in the topology
MO
must be the
and
AntennaPort changed MOs
unique.
working
is standard of
1,2,4,8 None None RE 3. equal
by Aadding to or
multi-level the
the
larger
removing BBP valueMO must
chain can be set up
both
between support
corresponding RXNUM FDD,
only on CPRI port
TDD,
and or
1,2,4,8 None None RE 0, 1,TXNUM
AntennaPort
or 2. in
MOs.the
TDD_ENHANCE.
RRU
An MO. For
AntennaPort MO
Therefore, if PS is
That
example,
cannot is, if Mode
an RRU in
set to abe valueremoved
0~255 None None RE the
None
with
ifgreater
it isBBP
one
used MO
TXby0, isaset
than HPN
to FDD,MO.
channel
Sector RS
and intwothe
in the CpriPort MO
RRU
RX
2. An MO
channels
RRU mustwitharebe
0~255 None None RE which
None is used by
set to
connected
8T8R LO, GL,
to
supports only UL,
the RRUCHAIN MO
or
theCL.
antenna
0~858993459, can only ports
chain beor setloadR0A
to
None None RE and
None
0, 1,R0B.
sharing or 2. If the
topology.
step:0.2 larger valueif
Therefore,
0~858993459, betweenisRXNUM
TXNUM set to 8,
None None RE None
and
TT inTXNUM the same is
step:0.2
changed,
RRUCHAIN MO the
0~858993459, number
must be ofset to
None None RE None
AntennaPort MOs
step:0.2 CHAIN or
must be changed
BALANCE.
0~858993459, by
An adding
RRU with or 8T8R
None None RE None
step:0.2 removing
can use only ports
corresponding
0 and 1. Therefore,
0~100000, step:10 None None RE None
ifAntennaPort
TXNUM is set MOs. to
AnHPN
8, AntennaPort
in the MO
cannot
CpriPort beMO removed
used
0~6553.5, step:0.1 None None RE None
ifbyit the
is used by a
RRUCHAIN
SectorMO.
MO must be set to
0~429496729.5, 0
None None RE None1.
or
step:0.1

-100~200 None None RE None


Avail_0, Avail_1,
Avail_20,
0~6 Avail_21, None None RE None
Avail_500,
Avail_501,
LO_TD, LO, WL,
Avail_504,
0~24 characters None None RE None
CL, CWL, GL,
Avail_508,
GWL, GCL, GCWL,
Avail_509,
UL, UWL,
Avail_520,
Alarm_0, UCL,
Alarm_1, None None RE None
CONNECTHEAD,
UCWL, UGL,
Avail_521,
Alarm_2, Alarm_3,
CONNECTTAIL,
UGWL, UGCL,
Avail_524,
Alarm_4, Alarm_5,
CONNECTBOTH,
UGCWL, NULL None None RE None
Avail_528,
Alarm_6, Alarm_7,
SEPERATEBYBRE
Avail_529,
Alarm_8, Alarm_9,
AK, LINKDOWN
Avail_800,
Alarm_10, None None RE None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None RE None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None RE None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None RE None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None RE None
Avail_c33,
Avail_c34,
0~31 characters None None RE None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None RE None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None RE None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None RE None
Avail_d29
0~19 characters None None RE None
LMPT, LBBP, FAN,
UPEU, UTRP, None None RE None
USCU, UEIU
0~4294967295 None None RE None

CPU, DSP None None RE None


-
2147483648~2147 None None RE None
483647
-
2147483648~2147 None None RE None
483647
0~255 characters None None RE None
Master, NDD, NCD,
NDC, NEC, EUL, None None RE None
EDL
CABINET,
SUBRACK,
None None RE None
BOARD,
SUBBOARD, SFP
0~63 characters None None RE None
0~63 characters None None RE None

0~63 characters None None RE None

0~63 characters None None RE None

1~39 characters None None RE None

Normal, Fault,
None None RE None
Timeout, NULL

0~65535 None None RE None

0~65535 None None RE None


1 WorkStandard in
the RFU MO must
be LO, and the
0~62 0 None RFU None
working standard of
Avail_0, Avail_1, the BBP must be
Avail_20,
4~5 Avail_21, None None RFU FDD.
None
Avail_500, 2. The RRUCHAIN
Avail_501, MO containing a
Avail_504,
0~5 None None RFU NoneMO cannot be
RFU
Avail_508, a multi-level chain,
Avail_509, namely that
MRFU, LRFU
Avail_520,
Alarm_0, Alarm_1, None None RFU
InsertPos in the
Avail_521,
Alarm_2, Alarm_3, RFU MO cannot be
Locked,
Alarm_4,Unlocked,
Avail_524,Alarm_5, greater
Unlocked Unlocked RFU None than 0.
Shutingdown
Avail_528,
Alarm_6, Alarm_7, 3. When RRUType
Avail_529,
Alarm_8, Alarm_9, is LRFU,
Avail_800,
Alarm_10, None None RFU None
WorkStandard can
Avail_801,
Alarm_11, be LO only. When
Avail_820,
Alarm_12, RRUType is MRFU,
Enabled,
Alarm_13,Disabled
Avail_821, None None RFU None
WorkStandard can
Avail_c10,
Alarm_14, be LO, GL, UL, or
Avail_c11,
Alarm_15 CL.
None None RFU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None RFU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None RFU None
Avail_c33,
Avail_c34,
0~31 characters None None RFU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None RFU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None RFU None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None RFU None
Avail_d29
0~19 characters None None RFU None
LMPT, LBBP, FAN,
UPEU, UTRP, None None RFU None
USCU, UEIU
0~4294967295 None None RFU None

CPU, DSP None None RFU None


-
2147483648~2147 None None RFU 1.
None PS in an RRU
483647 MO must be unique
- and consecutive on
2147483648~2147 None None RFU None
an RRU chain/ring.
483647 PS in an RFU MO
0~255 characters None None RFU must
None be set to 0.
If TT and BM in an
Master, NDD, NCD, 1. An RRU with
RRUCHAIN MO,
NDC, NEC, EUL, None None RFU 8T8R
None (eight
where the RRU TX or
EDL channels
You can
RFU MOspecify and eight
is the
CABINET, RX channels)
SUBRACK, VswrAlmThrhld
configured, are setonly
None None RFU supports
None
1.
when
to The
RING onlyHOT
number
the and the
of
BOARD, chain or load
SUBBOARD, SFP AntennaPort
VswrAlmSwitch
respectively, PS is MOs in
sharing
is
setequal
the to
RRU ON.topology.
toorthe RFU
ON, OFF ON ON RFU 1. The
Therefore,
larger value
value of to
if set
If the
MO must be
ALMPROCTHRHL
RXNUM
between
VswrAlmSwitch
0. is set
RXNUM tois8,
D
TT
and
set must
in the
TXNUM be greater
same in the
1.5~10, step:0.1 25 25 RFU If
1
than20tothat
TT
RRUCHAIN
inOFF,
an
of MO
RRU MO.
VswrAlmThrhld
RRUCHAIN
2. For MO,is
1. If Mode
ALMTHRHLD.
must
example,
invalid. be set into
an the
RRU
where
ALMPROCTHRHL the RRU or
1.5~3, step:0.1 20 20 RFU BBP
2
with25
CHAIN MO
one or is
TX set to
RFU
D MO
must be or is greater
RAT_TDD
BALANCE.
channel andistwo
configured,
than the set to
TDD_ENHANCE,
An
RX RRU
channels withPS 8T8R
are
BALANCE,
RCN
ALMTHRHLD. and PS in
must
0~3 None None RFU RS
can in
connectedusetheonly RRU
toRFU MO
ports
theunique
be RRU orin an
must
0 and
antenna be set to
1. Therefore,
ports R0A
MO
RRU must
or RFU be set MO. to
LO_TD.
ifand
RXNUMR0B. isthe
If set to
0~249 None None RFU 0.
That is, the position
2.
8, If RS in the
the RRU
2. HPN
larger
of RCN
an RRU
in
value
and orPS RFU
MO
CpriPort
between is not MO set
RXNUM to
used
must
in thebe unique in
topology
LO_TD,
by its value
TRUNK TRUNK None RFU an the
None
and
must RRUTXNUM
be
RRUCHAIN
or RFUMO.
unique. is
cannot
MO be greater
Thatmust
changed, is, the be
the set to
position
than
0 2. of
LO_TD, LO, CL, ofor an1.RRU
number or RFU
None None RFU 3.
2. RS
The
AntennaPort innumber
the RRU MOs of
GL, UL in the topology
MO and
AntennaPort
must be thechanged MOs
unique.
working
is standard of
1,2,4,8 None None RFU 3. equal
by Aadding to or
multi-level the
the
larger
removingBBP valueMO must
chain can be set up
both
between support
corresponding RXNUM FDD,
only on CPRI port
1,2,4,8 None None RFU TDD,
and
AntennaPort or
TXNUM in
MOs.the
0, 1, or 2.
TDD_ENHANCE.
RRU
An MO.
AntennaPort For MO
Therefore, if PS is
That
example,
cannot is,beif Mode
an RRU
removed in
set to a value
0~255 None None RFU the
None
with BBP
ifgreater
it is one
used MO
TXby0, isaset
than HPN
to FDD,
channel
Sector MO. the
RS
and intwo
in the CpriPort MO
RRU
RX
2. An MO
channels
RRU must
witharebe
0~255 None None RFU which
None is used by
set to supports
connected
8T8R LO, GL, to UL,
the RRUCHAINonly MO
or CL.
antenna
0~858993459,
the
can only ports
chain beor set
loadR0A
to
None None RFU and
None
0, 1,R0B.
sharing or 2. If the
topology.
step:0.2 larger value
Therefore, if
0~858993459, between
TXNUM isRXNUM set to 8,
None None RFU None
and
TT inTXNUM
the same is
step:0.2
changed, theMO
RRUCHAIN
0~858993459, number
must be of set to
None None RFU None
AntennaPort MOs
step:0.2 CHAIN or
must
BALANCE. be changed
0~858993459, by
An adding
RRU with or 8T8R
None None RFU None
step:0.2 removing
can use only ports
corresponding
0 and 1. Therefore,
0~100000, step:10 None None RFU None
AntennaPort
if TXNUM is set MOs. to
An
8, HPN in the MO
AntennaPort
cannot beMO
CpriPort removed
used
if it the
by is usedRRUCHAIN by a
SectorMO.
MO must be set to
0 or 1.
0~6553.5, step:0.1 None None RFU None

0~429496729.5,
None None RFU None
step:0.1

-100~200 None None RFU None

0~6 None None RFU None

LO_TD, LO, WL,


0~24 characters None None RFU None
CL, CWL, GL,
GWL, GCL, GCWL,
UL, UWL, UCL, None None RFU None
CONNECTHEAD,
UCWL, UGL,
CONNECTTAIL,
UGWL, UGCL,
CONNECTBOTH,
UGCWL, NULL None None RFU None
SEPERATEBYBRE
AK, LINKDOWN
0~63 characters None None RFU None

0~63 characters None None RFU None

0~63 characters None None RFU None

0~63 characters None None RFU None

1~39 characters None None RFU None

Normal, Fault,
None None RFU None
Timeout, NULL

0~65535 None None RFU None

0~65535 None None RFU None


1. If RRUType is set
to LRRU,
0 0 0 RRU WorkStandard
None can
be LO or LO_TD. If
RRUType is set to
60~254 None 60 RRU None
MRRU,
WorkStandard can
be LO, LO_TD, GL,
0 0 None RRU None
UL, or CL.
2. If RRUType in
0~30 characters NULL None RRU the
None RRU MO are
set to LRRU and
WorkStandard is
MRRU,
Alarm_0,LRRU
Alarm_1, None None RRU set to LO_TD, the
Alarm_2, Alarm_3, RRUCHAIN MO
Locked, Unlocked,
Alarm_4, Alarm_5, does not support
Unlocked Unlocked RRU None
the ring topology.
Shutingdown
Alarm_6, Alarm_7,
Alarm_8, Alarm_9, 3. When the RRU
Alarm_10, None None RRU type
Noneis changed,
Alarm_11, the current RRU
Alarm_12, must be reset.
Enabled,
Alarm_13,Disabled None None RRU 4. WorkStandard in
None
Alarm_14, the RRU MO and
Alarm_15 the working
standard of the
BBP MO must both
be FDD or TDD.
Avail_528,
Avail_529,
Avail_800,
Avail_801,
Avail_820,
Avail_821,
Avail_c10,
Avail_c11,
None None RRU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None RRU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None RRU None
Avail_c33,
Avail_c34,
0~31 characters None None RRU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None RRU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None RRU None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None RRU None
Avail_d29
0~19 characters None None RRU None
LMPT, LBBP, FAN,
UPEU, UTRP, None None RRU None
USCU, UEIU
0~4294967295 None None RRU None

CPU, DSP None None RRU None


-
2147483648~2147 None None RRU 1.
NonePS in an RRU
483647 MO must be unique
- and consecutive on
2147483648~2147 None None RRU None
an RRU chain/ring.
483647 PS in an RFU MO
0~255 characters None None RRU must
None be set to 0.
If TT and BM in an
Master, NDD, NCD, RRUCHAIN MO,
NDC, NEC, EUL, None None RRU where
None the RRU or
EDL
CABINET, You can
RFU MOspecify
is the
SUBRACK, VswrAlmThrhld
configured, only
are set
None None RRU None
when
to RING theand HOT
BOARD,
SUBBOARD, SFP VswrAlmSwitch
respectively, PS isin
set to
the RRUON.or RFU
ON, OFF ON ON RRU 1. The value of to
If
MO the must be set
ALMPROCTHRHL
VswrAlmSwitch is
0.
D
set must be greater
1.5~10, step:0.1 25 25 RRU If
1 20tothat
TT
than
inOFF,
an
of MO,is
VswrAlmThrhld
RRUCHAIN
2.
1. If Mode
ALMTHRHLD.
invalid. in the
where the RRU or
ALMPROCTHRHL
1.5~3, step:0.1 20 20 RRU BBP
2 25 MO is set to
MO is
RFU
D must be or greater
RAT_TDD
configured,
than the is set to
TDD_ENHANCE,
BALANCE,
RCN PS in
0~3 None None RRU RS inand
ALMTHRHLD.the PSRRU must
MO
theunique
be RRU orinRFU an
must be set to
MO must
RRU or RFU be set
MO.to
LO_TD.
0~249 None None RRU 0. is, the position
That
2. If RS in the RRU
2.
of RCN andorPS
MOanisRRU not set RFUto
must
in the be unique in
topology
TRUNK TRUNK None RRU LO_TD,
None its value
an RRU
must bebeor RFUMO.
unique.
cannot greater
That is, the position
than 2.
LO_TD, LO, CL, of an RRU or RFU
None None RRU 3. RS in the RRU
GL, UL in the topology
MO and the
must be unique.
working standard of
3. A multi-level
the BBP MO must
chain can be set up
both support FDD,
only on CPRI port
TDD, or
0, 1, or 2.
TDD_ENHANCE.
Therefore, if PS is
That is, if Mode in
set to a value
the BBP MO is set
8, HPNvalue
larger in the
CpriPort MO
between RXNUM used
by the
and RRUCHAIN
TXNUM is
MO must be
changed, theset to
0 or 1. of
number
2. The number
AntennaPort of
MOs
AntennaPort
must be changed MOs
is equal
by adding to or
the
1,2,4,8 None None RRU
larger value
removing
between
corresponding RXNUM
1,2,4,8 None None RRU and
AntennaPort in
TXNUM the
MOs.
RRU
An MO. For MO
AntennaPort
example,
cannot bean RRU
removed
0~255 None None RRU None
ifwith
it isone
used TXby a
channel
Sector MO. and two
RX
2. channels
An RRU with are
0~255 None None RRU None
connected
8T8R to only
supports
antenna
the chainports R0A
or load
0~858993459, and
None None RRU NoneR0B.
sharing If the
topology.
step:0.2 larger valueif
Therefore,
0~858993459, between
TXNUM isRXNUM set to 8,
None None RRU None
and
TT inTXNUM
the same is
step:0.2
changed, theMO
RRUCHAIN
0~858993459, number
must be of
set to
None None RRU None
AntennaPort MOs
step:0.2 CHAIN or
must
BALANCE. be changed
0~858993459, by
An adding
RRU with or 8T8R
None None RRU None
step:0.2 removing
can use only ports
corresponding
0 and 1. Therefore,
0~100000, step:10 None None RRU None
AntennaPort
if TXNUM is set MOs.
to
An
8, HPN in the MO
AntennaPort
cannot beMO
CpriPort removed
used
0~6553.5, step:0.1 None None RRU None
if it the
is used by a
by RRUCHAIN
SectorMO.
MO must be set to
0~429496729.5, 0 or 1.
None None RRU None
step:0.1

-100~200 None None RRU None

0~6 None None RRU None

LO_TD, LO, WL,


0~24 characters None None RRU None
CL, CWL, GL,
GWL, GCL, GCWL,
UL, UWL, UCL, None None RRU None
CONNECTHEAD,
UCWL, UGL,
CONNECTTAIL,
UGWL, UGCL,
CONNECTBOTH,
UGCWL, NULL None None RRU None
SEPERATEBYBRE
AK, LINKDOWN
0~63 characters None None RRU None

0~63 characters None None RRU None

0~63 characters None None RRU None

0~63 characters None None RRU None

1~39 characters None None RRU None

Normal, Fault,
None None RRU None
Timeout, NULL

0~65535 None None RRU None


cannot be set to the
1.
sameIf TTvalue is setfor tothe
CHAIN,
ring topology. BM must
be
4. IfsetTTtoisCOLD. set to If
TT is set to and
BALANCE RING,
BM can
Mode in the BBP be set to
either
MO is TDD COLD or
HOT.
or If TT is set to
TDD_ENHANCE,
0~65535 None None RRU None
BALANCE,
the CpriPortBM MOis
invalid.
can only be ports 0
0~249 None None RRUCHAIN 2.
None
or If
1.TT That is set to
is, HPN
RING
and TPN in theis set
and BM
CHAIN, RING, to HOT, SN in
RRUCHAIN MO the
None None RRUCHAIN two CpriPort MOs
LOADBLANCE cannot be greater
under
than 1.the BBP MOs
can
5. If beTT set is set to to
two
COLD, HOT None None RRUCHAIN
values
BALANCE and2, of 0, 1,
and
Mode 3,inexcept
the BBP 0 and
0~7 None None RRUCHAIN 1.
NoneBefore
MO is FDD, the
configuring
CpriPort MOmultiple can
hot
onlybackup
be ports rings
0 toon 2.
0~1 None None RRUCHAIN None
two LBBPs, ensure
That is, HPN and
that
TPNSN in the in the BBP
MOs
RRUCHAIN can only MO be
0~5 None None RRUCHAIN None
set
cannotto 2be or greater
3.
3.
thanIf TT2. is set to
0~5 None None RRUCHAIN RING
None
6. If TTand is setBMtois set
This
to HOT, parameter
RING or BALANCE,the is
valid
CpriPort only
two CpriPort MOs when
must be the
0~7 0 None RRUCHAIN topology
configured
used byvaluethe of isring
typeunderis
This
1.
or The
load
differentparameter
sharing
BBPMO MOs.
RRUCHAIN
valid only when
breakpoint 1 cannot the
mode.
may be configured
0~1 0 None RRUCHAIN topology
be greater type
than is the
ring
This
1.
on
or The
one
load
number parameter
value
or
oftwo
sharing
RRU ofBBPis
valid
MOs.only
breakpoint
mode.
levels Ifonthey when
the2 are
cannotthe
0~5 0 None RRUCHAIN topology
be greater
configured
RRUCHAIN type MO.isring
than
on is
twothe
This
or load
number
BBP parameter
MOs, sharing
of RRU
the
2. Theonly
valid value when oftwo the
mode.
levels
BBP MOs
breakpoint on the
must RRU
2 on a
0~5 0 None RRUCHAIN topology
chain/ring.
have the type
same is ring
WM.
chain
or load mustsharing be 255,
2. Breakpoint
7. If TTisisinvalid.
which set to 2 on
mode.
an RRU chain
0~4,255 255 255 RRUCHAIN RING,
3. The the
value ofmust
CpriPort
be
MO 255,
can
breakpoint 1 on which
only be isa
invalid.
ports
ring or 0, 1,
the or
load2.
0~4,255 255 255 RRUCHAIN If
3. AT
ThatThe in an
is,value
HPN of
and
sharing
RRUCHAIN mode
breakpoint
TPN in be
cannot 1 MO
thegreateron an is
set
RRU toring
RRUCHAIN PEERPORT,
or the
MO
LOCALPORT, LOCALPORT(local than the value of
None RRUCHAIN HSN
load
cannot in bethe
sharing same
mode
greater
PEERPORT port) breakpoint 2, and
RRUCHAIN
cannot
than 2. be MO
greater
the
must twobe breakpoints
set to 2 or
0~3 None None RRUCHAIN than
must
None the
exist value
or beof
3.
breakpoint 2, and
removed at the
the
same two breakpoints
time.
0~3 None None RRUCHAIN must
None exist or be
removed at the
same time.
0~62 0 None RxBranch None

4~5,60~254 None None RxBranch None

When the TMA is


0~5 None None RxBranch None
not used, the
recommended
0~7 None value
None of the RxBranch None
attenuation is 0.
When a 12 dB TMA
ON, OFF ON ON
is used, the RxBranch None
recommended
value of the
0~22, step:0.5 0 RxBranch None
attenuation ranges
from 4 dB to 11 dB.
When a 24 dB TMA
is used, the
recommended
value of the
attenuation ranges
from 11 dB to 22
2T2R mode.
3. The antenna
ports used by a
consolidation sector
must be located on
two RRUs or RFUs.
4. When a common
ON, OFF None None RxBranch MIMO
None sector in
TDD mode is used,
4T4R sectors are
0~11 None None Sector None
set up on the RRU
with 8 TX channels
-180~180, step:1e- and 8 RX channels,
None None Sector None
and the channels
6
must be in the
-90~90, step:1e-6 None None Sector same
None polarization
direction. That is,
the AntennaPort
1T1R, 1T2R, 2T2R,
None None Sector MOs used by the
2T4R, 4T4R, 8T8R
Sector MOs in this
case must be one
0~62 None None Sector None
of the following
combinations: R0A,
4~5,60~254 None None Sector R0B,
None R0E, and R0F
ports; R0B, R0D,
R0F, and R0H
0~5 None None Sector ports;
None R0C, R0D,
R0G, and R0H
R0A, R0B, R0C, ports. Meanwhile,
R0D, R0E, R0F, None None Sector None
CabinetNo,
R0G, R0H SubrackNo, and
0~62 0 None Sector SlotNo
None in the RRU
or RFU MOs where
the antenna ports
4~5,60~254 60 None Sector are
None located must be
the same.
5. The antenna
0~5 0 None Sector None used in the
ports
R0A, R0B, R0C, MIMO-mutual-aid
R0D, R0E, R0F, R0A None Sector scenarios
None must be
R0G, R0H located on two
RRUs or RFUs.
0~62 0 None Sector 6. When a common
None
MIMO sector in
TDD mode is used,
4~5,60~254 60 None Sector None
2T2R sectors are
set up on the RRU
with 4 TX channels
0~5 0 None Sector None
and 4 RX channels,
R0A, R0B, R0C, and the channels
R0D, R0E, R0F, R0A None Sector must
None be in the
R0G, R0H same polarization
direction. That is,
0~62 0 None Sector None
the AntennaPort
MOs used by the
Sector MOs in this
4~5,60~254 60 None Sector None
case must be one
of the following
0~5 0 None Sector combinations:
None R0A
and R0B ports;
R0A, R0B, R0C, R0C and R0D
R0D, R0E, R0F, R0A None Sector None Meanwhile,
ports.
R0G, R0H CabinetNo,
SubrackNo, and
0~62 0 None Sector None
SlotNo in the RRU
or RFU MOs where
4~5,60~254 60 None Sector the
None antenna ports
are located must be
the same.
sector. In TDD
mode, only 2T2R
supports
consolidation
sectors. In FDD
mode, only 2T2R,
2T4R, or 4T4R
supports
0~5 0 None Sector None
consolidation
sectors. The
R0A, R0B, R0C, consolidation or
R0D, R0E, R0F, R0A None Sector None
MIMO-mutual-aid
R0G, R0H sectors must be set
0~62 0 None Sector up
Noneon the single-
level of a chain on a
baseband
4~5,60~254 60 None Sector processing
None board,
namely that
When
InsertPos in the
0~5 0 None Sector None
SectorCombInd
RRU or RFU MOis
the combination
cannot be greater
R0A, R0B, R0C,
mode
than 0.of multiple
R0D, R0E, R0F, R0A None Sector None
RRUs,
2. When the following
R0G, R0H
requirements
SectorMode ismust set
0~62 0 None Sector be
to
Nonemet:
mutual-aid
1) AntennaMode
MIMO, the antenna
must
ports be
must setmeet
to the
4~5,60~254 60 None Sector None
2T2R.
following
2) The RRU/RFU
requirements:
MOs
1) of the
AntennaMode is
0~5 0 None Sector None
AntennaPort
set to 2T2R only. MOs
R0A, R0B, R0C, used
2) All by
RRU theorSector
RFU
R0D, R0E, R0F, R0A None Sector MOs
None must
of the be
R0G, R0H located
AntennaPorton theMOs
same
used by chain
the or the
Sector
0~62 0 None Sector None
same
MOs are levelonofthe
a
chain. If a sector
single-level of a is
configured
chain, namely withthat
4~5,60~254 60 None Sector None
multiple
InsertPosRRUs in theon
the
RRUsameor RFU chain,
MO is
0~5 0 None Sector there
None is a maximum
0.
of
3) two RRUs on the
CabinetNo1,
R0A, R0B, R0C, chain. If a sector
SubrackNo1, andis
R0D, R0E, R0F, R0A None Sector None arewith
configured
SlotNo1 not all
R0G, R0H multiple
the sameRRUs as on
NormalMIMO, NormalMIMO(Norm different
CabinetNo2, chains,
None Sector there can be only
AIDMIMO al MIMO) SubrackNo2, and
one RRU on each
SlotNo2.
0~30 characters None None Sector chain.
4) PortNo1 differs
None
3) All PortNo2,
from the RRUsand of
the
onlyAntennaPort
the R0A and
-32767~32767 None None Sector Noneports
MOs
R0B used areby the
used.
Sector
5) All theMOsRRUsare of
connected
the AntennaPortto the
0~1800000 3 None Sector None
same BBP.by the
MOs used
4) CabinetNo1,
Sector MOs are
0~1800000 3 None Sector SubrackNo1,
connected
None and
to the
SlotNo1;
same BBP.
CabinetNo2,
6) The CpriPort MO
0~179 0 None Sector None
SubrackNo2,
connected and
to the
SlotNo2;
RRUChain MO that
CabinetNo3,
contains the RRU
0~990 3 None Sector None
SubrackNo3,
or RFU MO must and
SlotNo3;
meet the following
0~100 0 None Sector CabinetNo4,
requirements:
None
SubrackNo4,
(1) Only portsand 0 to
COMBTYPE_SING
SlotNo4
2 can bemust usedmeet
as
LE_RRU, COMBTYPE_SING
None Sector the following
CpriPort MO
COMBTYPE_MULT LE_RRU
requirements:
that is connected to
I_RRU
a.
theCabinetNo1,
RRUChain MO.
SubrackNo1,
(2) The serialand
SlotNo1
numbersare the
of the
same as
AntennaPort and
CabinetNo2,
CpriPort MOs must
SubrackNo2,
meet one of the and
SlotNo2
following
The LONGITUDE
1.
and When GCDF is
LATITUDE
SEC,This
parameters are
parameter
valid onlyGCDFmust this
when be
1. When
specified in the is
parameter
SEC,This is set to
format
DEG. of
The
parameter
dd:mm:ss.ssss, must dd be
ANTLATITUDESEC
specified in the
DEG, SEC DEG None Sector indicates the
FORMAT
format of and
degree ranging
ANTLONGITUDES
ddd:mm:ss.ssss,
from 90 to 90, mm
0~16 None None Sector ECFORMAT
ddd indicates the
indicates
parameters theareminute
degree
ranging ranging
from 0 tothis
valid
If only
this180
from when
parameter
to 180, is
0~16 None None Sector 59, and
parameter
set to ss.ssss
TRUE, is set
the to
mm indicates
indicates the the
SEC.
cell
minuteis anranging from
second ranging
omnidirectional cell.
FALSE, TRUE FALSE None Sector 0 to
from 59, and
0parameter ss.ssss
to 59.9999.
If this
indicates the isis
2.
set When
to GCDF
FALSE, the
second
SEC,This ranging
paramter
0~50, step:0.1 None None Sector cell
None
from is not an
is not0NULL.
to 59.9999.
omnidirectional
2. When GCDF cell. is
SEC,This paramter
Normal, NoLicense None None Sector None
is not NULL.

0~40 characters None None Sector None

0~40 characters None None Sector None

0~62 0 0 SFP None

0~1,4~5,60~254 None None SFP None

0~7 None None SFP None

0~5 None None SFP None


INPOSITION,
NOTINPOSITION, None None SFP None
INVALID
SFP, ESFP,
ELEC_SFP, None None SFP None
UNKNOWN
0~15 characters None None SFP None
SINGLEMODE,
MULTIMODE, None None SFP None
UNKNOWN
0~65535 None None SFP None

0~25500, step:100 None None SFP None

0~255 None None SFP None

0~25500, step:100 None None SFP None

0~2550, step:10 None None SFP None

0~2550, step:10 None None SFP None

-128~128,
None None SFP None
step:0.001
0~6553500,
None None SFP None
step:100

0~131070, step:2 None None SFP None

0~6553.5, step:0.1 None None SFP None

0~6553.5, step:0.1 None None SFP None

0~2550 None None SFP None

0~62 0 None TxBranch None

4~5,60~254 None None TxBranch None

0~5 None None TxBranch None

0~7 None None TxBranch None

ON, OFF ON ON TxBranch None

1~25, step:0.01 None None TxBranch None

ON, OFF None None TxBranch None

0~4294967295 None None TxBranch None

0~100000, step:10 None None TxBranch None

0 0 None BITS None

0~7 0 0 BITS None

0~1 0 0 BITS None

0~7 0 0 BITS None

DEACTIVATED,
None None BITS None
ACTIVATED
UNAVAILABLE,
None None BITS None
AVAILABLE

1~4 4 4 BITS None

0 0 0 LineClk None

0~7 0 0 LineClk None


0~1 0 0 LineClk None

0~5 4 4 LineClk None

0~7 0 0 LineClk None

DEACTIVATED,
None None LineClk None
ACTIVATED
UNAVAILABLE,
None None LineClk None
AVAILABLE

1~4 4 4 LineClk None

0 0 0 PeerClk None

DEACTIVATED,
None None PeerClk None
ACTIVATED
UNAVAILABLE,
None None PeerClk None
AVAILABLE

0~1 0 0 TOD None

IN, OUT IN(Input) IN(Input) TOD None

0~7 0 0 TOD None

0~1 0 0 TOD None


If two TOD MOs are
configured, they
0~5 0 None TOD
should have the
same SN.
TWISTED-PAIR, TWISTED-
None TOD None
COAXIAL PAIR(Twisted-Pair)

0~1000 0 None TOD None

DEACTIVATED,
None None TOD None
ACTIVATED
UNAVAILABLE,
None None TOD None
AVAILABLE

0~100000 None 0 TOD None

1~4 4 4 TOD None

0~1 0 0 GPS None

0~7 0 0 GPS None

0~1 0 0 GPS None


0~7
USER_CONFIG, 7 None GPS None
SEARCH_WITH_D
URATION, AUTO_SEARCH(A
None GPS None
SEARCH_WITH_P uto Search)
RECISION,
-180~180, step:1e-
AUTO_SEARCH 0 None GPS None
6

-90~90, step:1e-6 0 None GPS None

-1000~10000 0 None GPS None

0~89 5 None GPS None

0~100000 None 0 GPS None

1~2880 1 None GPS None

1~100 1 None GPS None

TWISTED-PAIR,
COAXIAL(Coaxial) None GPS None
COAXIAL

0~1000 0 None GPS None

Lock, Unlock None None GPS None

Valid, Invalid None None GPS None

Valid, Invalid None None GPS None

NotFixed, Fixed None None GPS None

Enabled, Disabled None None GPS None

NOTEXIST,
Valid, Invalid
ANTENNASHORTE None None GPS None
D,
ANTENNAOPENE
0~100 None None GPS None
D,
M12M, UT, RT,
SELF_CHECK_FAI
JPS15L, K161,
LURE,
GG16, JNS100, None None GPS None
COMEXCEPTION,
RGPS, CWAIN,
NORMAL,
RTSMT, UBLOX5,
UNKNOWN, None None GPS None
BD7702, NAVIOR,
USCUINVALID,
PPSTOD, M1000,
UNKNOWN_STAR
TRGPS,
0~100 None None GPS None
_CARD
GPS, GLONASS,
BD7702CMS,
GPS/GLONASS,
OEM4, UNKNOWN
COMPASS, GPS(GPS) GPS(GPS) GPS None
COMPASS/GPS,
GPS/COMPASS
0~100 None None GPS None
in the
corresponding
DEVIP MO cannot
be set to LOOPINT.
3. If two IPCLKLNK
MOs are configured
and ICPT in the
DEACTIVATED, MOs are both set to
None None GPS None
ACTIVATED PTP, the two MOs
must have the
1~4 4 4 GPS same
None CN, SRN,
SN, CNM, DM,
CMPST,
0~1 0 0 IPCLKLNK None
DELAYTYPE, and
PRI. If CNM in the
HW_DEFINED, MOs are both set to
PTP(PTP Protocol) PTP(PTP) IPCLKLNK
PTP UNICAST, the two
MOs must have the
0~7 0 0 IPCLKLNK same
None
PROFILETYPE,
ANNFREQ,
1. CIP cannot be
0~1 0 0 IPCLKLNK None
SYNCFREQ,
set to 0.0.0.0 or and
NEGDURATION.
255.255.255.255.
4. This
2. If two IPCLKLNK
0~7 7 6 IPCLKLNK None parameter is
MOs
1. are
Theonly
valid configured
values when of
1.
anyThis
When
and
CNMtwo ICPT parameter
and CNM
parameters
in the is
Valid IP address 0.0.0.0 None IPCLKLNK valid
in the
among only
CLASSIDENTIFY
MOs when
CLASS0,
IPCLKLNK MO is are set is
1.
to When
CNM
setPTPsetin
to
CLASS1,
not OFF,the
and
to the
CLASS2,
CLASSIDENTIFY
IPCLKLNK
BMC
and algorithm
L2_MULTICAST
CLASS3
L2_MULTICAST. MO is is in
Valid IP address 0.0.0.0 None IPCLKLNK the
not IPCLKLNK
set
disabled,
respectively,
cannot
3. to and
be the of
In parameter
one theMO
1.
is The
This
set tovalues
OFF, is
L2_MULTICAST.
settings
MACMODE
same.
IPCLKLNK of MO, inthetheSIP
any
valid
BMC
2. SIP two
only parameters
algorithm
cannot when be is
CLASS0,
two
2. When
must MOs
be CLASS1,
must
different be
0~127 0 0 IPCLKLNK among
ICPT
disabled,
set in CLASS0,
the
toparameter
0.0.0.0 and the
or
CLASS2,
1. The
from
This YES
CLASSIDENTIFY
values
CIP. andand ofis in
CLASS1,
IPCLKLNK
setting of
255.255.255.255. CLASS2,
MO
CLASS1 is
CLASS3
CLKMAC
the
any
valid IPCLKLNK
two
only do
parameters
when not
in theMO two
and
set
does toCLASS3
PTP.
not take
take
MOs
is seteffect.
must
tobeOFF, beWhenset to
E2E, P2P E2E(E2E) E2E(E2E) IPCLKLNK among
ICPT
cannot
effect.
in CLASS0,
the
When the the
CLASSIDENTIFY
different
BMC
CLASS1,
IPCLKLNK values.
algorithm MO is
CLASS2, is is
same.
CLASSIDENTIFY in
set
5. Iftotwo
disabled,
and
setWhen ON,
CLASS3
to PTP. the
IPCLKLNK
and BMC
the
2.
the IPCLKLNK MO
OFF, ON ON(ON) ON(ON) IPCLKLNK algorithm
MOs are
setting
cannot of isthe
beCLASS0
CLASSIDENTIFY
is set notto ON, the inin
enabled.
configured,
does
same. If there
take ICPT
the
BMC IPCLKLNK
algorithm MO
is
are
the multiple
MOs
effect.
2. When WhenareTime both
0~255 6 6 IPCLKLNK is set
enabled. to OFF,
If therethe
Servers
set to PTP,
CLASSIDENTIFY of different
and
BMC
are algorithm
multiple Time is in
clock
CNM
the qualities,
in the MOs
IPCLKLNK the
MO
disabled,
Servers and
of different the
target
areset
is not server
to set
ON, isthe
tothe
0~255 13 13 IPCLKLNK setting
clock ofOFF,
CLASS2
qualities, the
selected
L2_MULTICAST,
BMC in
algorithm
does
target not
servertakeis is
descending
the two
enabled.
disabled, MOsIfand order
the of
must
there
effect.
selected Whenin
0~255 7 7 IPCLKLNK priority.
have
are the
multiple
setting Thesame
of CLASS3 Server
Time CIP.
CLASSIDENTIFY
descending order in
of
that
Servers
does isnot
6. If two closest
IPCLKLNK
of take to the
different
the IPCLKLNK
priority. The ServerMO
user's
MOs are
clock anticipation
0~255 14 14 IPCLKLNK is setisqualities,
effect.
that
When
toclosest
ON, the to
the
the
is selected
configured,
target server
CLASSIDENTIFY as
the
is the
two
BMC
user's algorithm
anticipation is in
target
MOs
selected
the server.
must
IPCLKLNK in have MOthe
enabled.
is selected If there
0~4294967295 None None IPCLKLNK same
descending
is set
None
are to
multipleON,as
ICPT. the
Time
the of
order
target
priority.
BMC server.
The
algorithm Serveris
Servers
2. The of different
values of
DEACTIVATED, that
clock is
enabled. closest
If
qualities, there tothethe
None None IPCLKLNK any
None
user's
are two parameters
anticipation
multiple Time
ACTIVATED target
among server
CLASS0, is
is selected
Servers
selected ofin as the
different
UNAVAILABLE, CLASS1,
target
clock server.
qualities,CLASS2, theof
None None IPCLKLNK descending
1. This
None
and CLASS3parameter order is
AVAILABLE target
This
priority.
valid server
parameter
only The when is is
Server
cannot
selected be the
inwhento the
valid
that
ICPT
same. isonly
inclosest
the
UNICAST, descending order
L2_MULTICAST
UNICAST(Unicast) UNICAST(Unicast) IPCLKLNK ICPT
user'sinanticipation
IPCLKLNK the MO is of
priority.
IPCLKLNK
is selected
set The
to PTP. as the Server
MO is
that
2. If ICPT in the the
set to
target is closest
PTP.
server. to
-100000~100000 0 0 IPCLKLNK user's anticipation
IPCLKLNK MO is
is selected
set to as the
ONE_STEP, target
HW_DEFINED,server.
None None IPCLKLNK None
TWO_STEP CMPST in the
IPCLKLNK MO
0~4094 None None IPCLKLNK None be set.
cannot
-
2147483648~2147 None None IPCLKLNK None
483647
1~4 4 4 IPCLKLNK None

1/16, 1/8, 1/4, 1/2,


1/2(1/2) None IPCLKLNK None
1.0, 2.0, 4.0, 8.0
1/2, 1.0, 2.0, 4.0,
8.0, 16.0, 32.0, 16.0(16.0) None IPCLKLNK None
64.0, 128.0
0~255 255 None IPCLKLNK None

1588V2, G.8265.1 1588V2(1588V2) None IPCLKLNK None

60~1000 300 None IPCLKLNK None

0 0 0 SyncEth None

0~7 0 0 SyncEth None

0~1 0 0 SyncEth None

0~7 7 6 SyncEth None


When SN in the
SyncEth MO refers
0~1 0 0 SyncEth to the main control
board, PN is set to
0 or 1.
DISABLE, ENABLE DISABLE None SyncEth None

DEACTIVATED,
None None SyncEth None
ACTIVATED
UNAVAILABLE,
None None SyncEth None
AVAILABLE

1~4 4 4 SyncEth None


AVAILABLE,
UNAVAILABLE,
None None Tasm None
UNSUPPORT,
PARTAVAILABLE
FORBID, ALLOW, 1. If MODE is set to
None None Tasm None
This parameter
NA MANUAL and is
valid
CLKSRC only is when
set to
1~4 None None Tasm more
None than
SYNCETH+IPCLK one
clock link is
or GPS+SYNCETH,
supported
MODE cannot by the
be
0, 1, AUTO
GPS, BITS, IPCLK, 0(0) None Tasm clock
switchedsource that is
to AUTO.
This parameter
specified through is
SYNCETH, If MODE needs to
valid
CLKSRC only when
in the
LINECLK, TOD, be switched, MODE
GPS(GPS Clock) GPS(GPS Clock) Tasm MODE
Tasm in the
MO, and Tasm
PEERCLK, must be set to
MO is
meanwhile set toMODE
SYNCETH+IPCLK, FREE or CLKSRC
AUTO, MANUAL, MANUAL.
is set to MANUAL.
GPS+SYNCETH AUTO(Auto) AUTO(Auto) Tasm must be set to
FREE
values other than
SYNCETH+IPCLK
FREQ, PHASE FREQ(FREQ) None Tasm None
and
GPS+SYNCETH.
2. If MODE is set to
MANUAL, ensure
that the clock
source
corresponding to
CLKSRC and
NORMAL, LOST,
UNAVAILABLE,
FREDVAT, JITTER,
None None Tasm None
PHASEOUTSCOP
FREERUNNING,
E, UNKNOWN,
FASTTRACKING,
DIFFSRC
LOCKED,
GPS, BITS, IPCLK, None None Tasm 1. If TYPE in the
None
HOLDOVER,
SYNCETH, Cabinet MO where
UNKNOWN
LINECLK, TOD, the Subrack MO is
None None Tasm None is set to
located
PEERCLK,
QL-PRC, QL-SSU-
SYNCETH+IPCLK, BTS3900 or RFC,
A, QL-SSU-B,
GPS+SYNCETH QL- QL-SSU-B(QL- only one RFU can
None Tasm None
be added in the
EEC2, QL-EEC1, SSU-B)
QL-DNU subrack.
0~249 0 None CPRILBR 2. If TYPE in the
None
Subrack MO is set
LBR0, LBR1, LBR2, to BBU3900, CN
LBR3, LBR4, LBR5, None None CPRILBR None be greater
cannot
LBR6
NEGOTIATED, than 7.
NEGOTIATING, 3. If TYPE in the
None None CPRILBR None
Subrack MO is set
NOTREADY,
TIMEOUT
LBR0, LBR1, LBR2, to BBU3900, SRN
LBR3, LBR4, LBR5, None None CPRILBR cannot
None be greater
LBR6 than 1.
NEGOTIATED,
4. If TYPE in the
NEGOTIATING,
None None CPRILBR None
Subrack MO is set
NOTREADY,
to RFU, SRN is set
TIMEOUT
to 4 or 5.
0~62 None None CPRILBR None
5. If TYPE in the
Subrack MO is set
0~254 None None CPRILBR to TCU, SRN must
None
be set to 8 or 14,
and only the TCU
0~7 None None CPRILBR can
None be added in the
subrack.
6. If TYPE in the
HEAD, TAIL None None CPRILBR None
Subrack MO is set
LBR0, LBR1, LBR2, to FMU, SRN must
LBR3, LBR4, LBR5, None None CPRILBR be
Noneset to 11 or 12,
LBR6 and only the FMU
can be added in the
DC, AC DC(DC) None ENERGYCON subrack.
None
7. If TYPE in the
Subrack MO is set
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) PSUIS None
to PMU, SRN must
be set to 7 and only
0~62 None None Cabinet the
None PMU can be
APM30, TMC, BBC, added
1. When in the
the cabinet
PS4890, OMB, subrack.
number ranges
VIRTUAL(Virtual 8. If TYPE
RFC, BTS3900, None Cabinet None
from 0 to 7 in
andthethe
Cabinet) Subrack MO is set
BTS3900L, subrack number is
VIRTUAL to RFU,
0 or TYPE
1, the subrackof
0~79 characters None None Cabinet None
the
can cabinet
be a 2 U must
BBUbe
set to RFC,
subrack.
BTS3900,
2. When the cabinet
0~31 characters None None Cabinet None
BTS3900L
number ranges or
VIRTUAL.
from 0 to 7 and the
0~62 None None Subrack 9. If TYPE
subrack in the is
number
Subrack
4 or 5, the MO is set
subrack
to
can only be an of
TCU, TYPE RF
0~254 None None Subrack None
the cabinet must be
subrack.
BBU3900, RFU, set to APM30,
3. When TMC,
the cabinet
PMU, TCU, FMU, BBC,
number OMB,
ranges
None None Subrack
RRU, EMU, PICO, BTS3900AL,
from 8 to 62 and
UNKNOW BTS3900S
the subrackor number
VIRTUAL.
is 4 or 5, the
10. If TYPE
subrack caninonlythebe
Subrack MO is set
an RF subrack.
to BBU3900, TYPE
of the cabinet must
be set to APM30,
Avail_0, Avail_1,
Avail_20, Avail_21,
Avail_500,
Avail_501,
Avail_504,
Avail_508,
Avail_509,
0~79 characters
Avail_520,
Alarm_0, Alarm_1, None None Subrack None
AC220V, DC-48V,
Avail_521,
Alarm_2,
DC+28V, Alarm_3,
DC+24V,
Avail_524,
Alarm_4,
DC-48V-2,Alarm_5,
AC110V, None None Subrack None
Avail_528,
Alarm_6,
RDC-48V,Alarm_7,
NDC-
Avail_529,
Alarm_8, Alarm_9,
48V
Avail_800,
Alarm_10, None None RU None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None RU None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None RU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None RU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None RU None
Avail_c33,
Avail_c34,
0~31 characters None None RU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None RU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None RU None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None RU None
Avail_d29
0~19 characters None None RU None
LMPT, LBBP, FAN,
UPEU, UTRP, None None RU None
USCU, UEIU
0~4294967295 None None RU None

CPU, DSP None None RU None


-
2147483648~2147 None None RU None
483647
-
2147483648~2147 None None RU None
483647
0~255 characters None None RU None
Master, NDD, NCD,
NDC, NEC, EUL, None None RU None
EDL
CABINET,
SUBRACK,
None None RU None
BOARD,
SUBBOARD, SFP
0~63 characters None None RU None

0~63 characters None None RU None

0~63 characters None None RU None


0~63 characters None None RU None

1~39 characters None None RU None

Normal, Fault,
None None RU None
Timeout, NULL

0~65535 None None RU None

0~65535 None None RU None

0~62 0 0 EMU None

40~59 40 40 EMU None

0 0 0 EMU None
When the EMU is
0~62 0 connected
0 to the EMU None
MON1 port on the
UPEU, set this
0~254 0 0
parameter to 1. EMU None
When the EMU is
connected to the
0~1 None EMU None
MON0 port on the
UPEU, set this
1~30 2 parameter
2 to 0. EMU None
When the EMU is TUTHD in the EMU
connected to the MO must be greater
-20~80 0 0
RRU, set this EMU
than TLTHD by 3%
parameter to 0. TUTHD in the
or a higher EMU
percent.
MO must be greater
-20~80 50 50 EMU
than TLTHD by 3%
HUTHD in the
or a higher EMU
percent.
MO must be greater
0~100 10
-48 Voltage 10
-48 Voltage EMU
than HLTHD by 5%
Disabled:OFF, Disabled:OFF, HUTHD in the
or a higher EMU
percent.
Reserved Sensor Reserved Sensor MO must be greater
0~100 80 80 EMU
48V_DISABLE, 0:ON, Reserved 0:ON, Reserved than HLTHD by 5%
RES0, RES1, Water
Sensor-Immersed
1:ON, Water
Sensor-Immersed
1:ON, or a higher percent.
RES2, Sensor
Reserved Sensor Sensor
Reserved Sensor EMU None
TS_DISABLE, Disabled:OFF,
2:ON, Temperature Disabled:OFF,
2:ON, Temperature
WS_DISABLE,
HS_DISABLE Smog
SensorSensor Smog
SensorSensor
SS_DISABLE,
Disabled:OFF,
Disabled:OFF, Disabled:OFF,
Disabled:OFF, EMU None
IS_DISABLE,
Infrared
HumiditySensor
Sensor Infrared
HumiditySensor
Sensor
-GS_DISABLE Disabled:ON, Disabled:ON,
Disabled:OFF
2147483648~2147 None Disabled:OFF
None EMU None
Gating Sensor Gating Sensor
483647 Disabled:OFF Disabled:OFF
0~100 None None EMU None

0.0~100.0 None None EMU None

-999.99~9999.99 None None EMU None

-999.99~9999.99 None None EMU None


Avail_0, Avail_1,
Avail_20, Avail_21,
Avail_500,
Avail_501,
Avail_504,
Avail_508,
Avail_509,
-999.99~9999.99
Avail_520,
Alarm_0, Alarm_1, None None EMU None
Avail_521,
Alarm_2, Alarm_3,
Avail_524,
Alarm_4, Alarm_5,
-999.99~9999.99 None None EMU None
Avail_528,
Alarm_6, Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
Avail_800,
Alarm_10, None None EMU None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None EMU None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None EMU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None EMU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None EMU None
Avail_c33,
Avail_c34,
0~31 characters None None EMU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None EMU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None EMU None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None EMU None
Avail_d29
0~19 characters None None EMU None
LMPT, LBBP, FAN,
UPEU, UTRP, None None EMU None
USCU, UEIU
0~4294967295 None None EMU None

CPU, DSP None None EMU None


-
2147483648~2147 None None EMU None
483647
-
2147483648~2147 None None EMU None
483647
0~255 characters None None EMU None
Master, NDD, NCD,
NDC, NEC, EUL, None None EMU None
EDL
CABINET,
SUBRACK,
None None EMU None
BOARD,
SUBBOARD, SFP
0~63 characters None None EMU None

0~63 characters None None EMU None

0~63 characters None None EMU None


0~63 characters None None EMU None

1~39 characters None None EMU None

Normal, Fault,
None None EMU None
Timeout, NULL

0~65535 None None EMU None

0~65535 None None EMU None

0~62 0 0 FMU None

11~12 11 11 FMU None

0 0 0 FMU None
When the FMU is
0~62 0 connected
0 to the FMU None
MON1 port on the
UPEU,
The FMUs set of
thisa
0~254 0 0
parameter to
maximum of two 1. FMU None
When can
levels the FMU
be is
connected to
connected to a
thebus.
0~1 None FMU None
MON0
The port on the
communication
UPEU,
addresssetof this
the FMU
1~30 14 parameter to 0.
that is directly FMU None
Water-Immersed Water-Immersed
When the FMU
connected to theis
Sensor Sensor
connected
BBU is set to
to the
14.
WS_DISABLE,
Disabled:ON, Smog Disabled:ON,
set this Smog
RRU,communication
The FMU None
SS_DISABLE
Sensor Sensor
parameter
address of tothe0.
Disabled:ON Disabled:ON
lower-level FMU is
0~100 None None FMU None
set to 15.
Avail_0, Avail_1,
Avail_20,
-127~127 Avail_21, None None FMU None
Avail_500,
Avail_501,
Avail_504,
-127~127 None None FMU None
Avail_508,
Avail_509,
0~4294967295
Avail_520,
Alarm_0, Alarm_1, None None FMU None
Avail_521,
Alarm_2, Alarm_3,
Avail_524,
Alarm_4,
DISABLE,Alarm_5,
ENABLE ENABLE(Enable) Disable(DISABLE) FMU None
Avail_528,
Alarm_6, Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
Avail_800,
Alarm_10, None None FMU None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled, Disabled
Avail_821,
Alarm_13, None None FMU None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None FMU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None FMU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None FMU None
Avail_c33,
Avail_c34,
Avail_d00,
Avail_d01,
Avail_d04,
Avail_d08,
Avail_d09,
Avail_d20,
0~31 characters None None FMU None

0~259 characters None None FMU None

0~11 characters None None FMU None

0~23 characters None None FMU None

0~19 characters None None FMU None


LMPT, LBBP, FAN,
UPEU, UTRP, None None FMU None
USCU, UEIU
0~4294967295 None None FMU None

CPU, DSP None None FMU None


-
2147483648~2147 None None FMU None
483647
-
2147483648~2147 None None FMU None
483647
0~255 characters None None FMU None
Master, NDD, NCD,
NDC, NEC, EUL, None None FMU None
EDL
CABINET,
SUBRACK,
None None FMU None
BOARD,
SUBBOARD, SFP
0~63 characters None None FMU None

0~63 characters None None FMU None

0~63 characters None None FMU None

0~63 characters None None FMU None

1~39 characters None None FMU None

Normal, Fault,
None None FMU None
Timeout, NULL

0~65535 None None FMU None

0~65535 None None FMU None

0~62 0 0 TCU None

8,14 8 8 TCU None


0 0 0 TCU None
For
When thethe
TCU TCU in ais
cabinet
connected other
to than
the
0~62 0 0 TCU None
BBC, the
MON1 port on the
recommended
UPEU, set this
0~254 0 value
0 is 7. For
parameter to 1.the TCU None
TCU
WheninthetheTCUBBC, is
the addresstoofthe
connected the
0~1 None PMU TCU None
MON0connected
port on the to
the BBC is
UPEU, set this 3, and
the addresstoof0.the
parameter
1~30 7 TCU None
level-1
When the TCU TCUis set
is
to 23the
and
connected
For TCUthat
toin ofthe
the the
-40~10 -20 level-2
-20 the
RRU,
BBC, TCU
set this is set TCU None
to 24. For the
parameter
recommended to 0.PMU
whose
value is 50. For is
address the4,
20~80 68 the address of the TCU None
Water-Immersed TCU in another
Water-Immersed
level-1
cabinet, TCU is set
Sensor Sensor the
WS_DISABLE, to 25 and that of
Disabled:ON, Smog recommended
Disabled:ON, Smog TCU None
SS_DISABLE level-2
value is 68. is set
TCU
Sensor Sensor
to 26.
Disabled:ON Disabled:ON
0~2 0 0 TCU None

DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) TCU None

-127~127 None None TCU None


Avail_0, Avail_1,
Avail_20,
-127~127 Avail_21, None None TCU None
Avail_500,
Avail_501,
Avail_504,
-127~127 None None TCU None
Avail_508,
Avail_509,
0~4294967295
Avail_520,
Alarm_0, Alarm_1, None None TCU None
Avail_521,
Alarm_2, Alarm_3,
Avail_524,
Alarm_4, Alarm_5,
0~4294967295 None None TCU None
Avail_528,
Alarm_6, Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
Avail_800,
Alarm_10, None None TCU None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None TCU None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None TCU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None TCU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None TCU None
Avail_c33,
Avail_c34,
0~31 characters None None TCU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None TCU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None TCU None
Avail_d21,
Avail_d24,
Avail_d28,
Avail_d29
0~23 characters None None TCU None

0~19 characters None None TCU None


LMPT, LBBP, FAN,
UPEU, UTRP, None None TCU None
USCU, UEIU
0~4294967295 None None TCU None

CPU, DSP None None TCU None


-
2147483648~2147 None None TCU None
483647
-
2147483648~2147 None None TCU None
483647
0~255 characters None None TCU None
Master, NDD, NCD,
NDC, NEC, EUL, None None TCU None
EDL
CABINET,
SUBRACK,
None None TCU None
BOARD,
SUBBOARD, SFP
0~63 characters None None TCU None

0~63 characters None None TCU None

0~63 characters None None TCU None

0~63 characters None None TCU None

1~39 characters None None TCU None

Normal, Fault,
None None TCU None
Timeout, NULL

0~65535 None None TCU None

0~65535 None None TCU None

0~62 0 0 HtCDPa None

8,14 8 8 HtCDPa None

0 0 0 HtCDPa None

LTCP must be
-99~70 0 0 HtCDPa
lower than HTCP.
HTCP must be
-99~70 40 40 HtCDPa
higher than LTCP.
-99~70 45 45 HtCDPa None

0~30 2 2 HtCDPa None

0~30 9 9 HtCDPa None

0~30 16 16 HtCDPa None

0~30 13 13 HtCDPa None

0~62 0 0 PMU None


1. FCV in the
7 7 7 PMU Battery
None MO
corresponding to
the SC48200 PMU
0 0 0 PMU MO
None minus 1.5V
must be greater
When the PMU is than or equal to the
0~62 0 connected
0 to the PMU None
smaller value
MON1 port on the between 46.5 V and
UPEU, set this DCVLTHD in the
0~254 0 0
parameter to 1. PMU None
PMU MO plus 0.5
When the PMU is V.
connected to the 2. The actual value
0~1 None PMU None
MON0 port on the of this parameter
UPEU, set this for the SC48200
1~30
APM100, APM200, 3 parameter
3 to 0. PMU None MO ranges
PMU
APM30, EPS4890, When the PMU is 1. This parameter is
from 46 V to 50 V.
EPS4815, connected to the valid only when
The actual value of
APM30(APM 30) APM30(APM
RRU, set this 30) PMU None
LSDF
When in the PMU
PTYPE is
SC48200, thisThis
1. parameter
parameter fornot
EPS48200, parameter to 0. MO
set is SC48200,
to set to
other
not types
for the of PMU
TP48300A ENABLE.
ACVLTHD infrom
the 35
60~300 180 180 PMU MO
SC48200
When ranges
PTYPEPMU isMO
2.
PMU If both
MO LSDF innot
The recommended V
settoto55.6
should V. thebe
meet
must
SC48200,
PMU
smaller MO and SDV
than
value of this 3. DCVLTHD
following
ACVLTHD for the
in the
60~300 280 280 PMU in Battery MO
ACVUTHD. equal
parameter for the APM30,
requirements:
PMU APM100,
MO mustSDV BCVbe
The recommended to "ENABLE",
SC48200 PMU is APM200,
in EPS4890,
value of this in the
smaller
BatteryBattery
MO MO
than must
470. The EPS48200
should
ACVUTHD. or
be smaller
35.0~55.6, step:0.1 450 parameter for the PMU be smaller than
recommended TP48300A
than PMU
The recommended
SC48200 PMU is LSDVDCVUTHDin other PMU in
value
value of
of this
this MO
the
LSDF should
PMU MO
in the beminus
585. The MO than SC48200.
58.0~60.0, step:0.1 580 parameter
parameter forfor other
the PMU greater
1 V.
SC48200 than
PMU LSDV MO
recommended 3. This parameter
types
The
SC48200of PMU
recommended
PMU isis in
2.
is the
This
set PMU
to parameter
ENABLE MO.
value of this for the SC48200
450.
value of this
ENABLE(Enable). 4.
for
by DCVLTHD
theMO SC48200
default. LSDFfor the in
parameter for PMU should
DISABLE, ENABLE DISABLE(Disable) parameter
The for other
recommended the PMU SC48200
PMU
other theMO
types PMU
should
of PMU MO
types of PMU isis meet following
SC48200
value PMU
of this should
meet
MO isthe notfollowing
set tobe SDV
580. requirements:
465. The for other
parameter smaller
requirements:
DISABLE than
by LSDV BCV
35.0~55.6, step:0.1 440 PMU in Battery MO must
recommended
types of PMU is in
in the
the
default. PMU
Battery MO MO plus
be smaller than
value of this 0.5
shouldV.
DISABLE(Disable). LSDV innot
ATLTHD in be
the the larger
PMU PMU
parameter for other 5.
thanIf LSDF
DCVUTHD in smaller
PMU
-20~20 0 0 PMU MO
MO mustplus be
-0.5 V. in
types of PMU is MO PMU
the
than equal
ATUTHD.MOto minus
4. When
ATLTHD LSDF
in the is
440. "DISABLE"
1.5 V. andPMU
35~80 50 50 PMU set to
MO must ENABLE,
be smaller the
SDV in Battery MO
following
than ATUTHD.
equal
AHLTHD to "ENABLE",
in the
requirements
SDV in
PMU MO Battery
must be MO
0~50 10 10 PMU should be met: The
must bethan
smaller smaller
actual
AHUTHD valuein theof this
than DCVLTHD
AHUTHD. in
parameter
PMU for the
50~100 80 80 PMU other MO PMUmust MO be than
SC48200
greater PMU MO
than
SC48200.
ranges from 45.5 V
AHLTHD.
6. FCV in Battery
to 48.5 V. The
MO should be
actual value of this
greater than
parameter for other
DCVLTHD in the
types of PMU MO
other PMU MO than
ranges from 35 V to
SC48200 plus 2 V.
55.6 V.
for the APM30,
Battery
PS4890, and
Temperature
SC48200 PMUs is
Sensor 1
set to OFF, and for
Disabled:OFF,
other PMUs is set
Cabinet Humidity Water-Immersed
to ON. Cabinet
Sensor Sensor
BT1_DISABLE, HumidityDisabled
Sensor
Disabled:ON, and SmogisSensor
AH_DISABLE, Water-Immersed Disabled set to
Cabinet Disabled are set to PMU None
AT1_DISABLE, Sensor ON. The Cabinet
Temperature ON. The Gating
BT2_DISABLE
WS_DISABLE, Disabled:ON, Smog Temperature
Sensor 1 Sensor
SS_DISABLE, Sensor Sensor Disabled
1 Disabled for
PMU None
Disabled:ON, the APM30,
GS_DISABLE Disabled:ON, for the APM100 and
- Battery APM100, and is
Gating Sensor APM200 PMUs
2147483648~2147 Temperature
None
Disabled:OFF
APM200
set to OFF, and is
None PMUs for PMU None
483647 Sensor 2 set to PMUs
OFF, and for
other is set
Disabled:ON other PMUs is set
to ON. Battery
-100.0~100.0 None None
to ON. PMU None
Temperature
Sensor 2 Disabled
-150.0~150.0 None is set to ON.
None PMU None
-
2147483648~2147 None None PMU None
483647
PowerOn,
LowVoltagePowerO
0~100 None None PMU None
ff,
MasterControlPowe
rOff, None None PMU None
HighTemperaturePo
BoostCharging,
werOff,
FloatCharging,
LowTemperaturePo None None PMU None
ForceBoostChargin
werOff
g, Discharging
-150.0~150.0 None None PMU None

PowerOn,
CurrentLimiting,
LowVoltagePowerO None None PMU None
NoCurrentLimiting
ff,
MasterControlPowe
None None PMU None
rOff,
ManualPowerOff,
HighTemperaturePo
0~100 None None PMU None
werOff
-
2147483648~2147 None None PMU None
483647
CHARGE,
DISCHARGE, REC, None None PMU None
END
-150.0~150.0 None None PMU None

-150.0~150.0 None None PMU None


-
2147483648~2147 None None PMU None
483647
0~4294967295 None None PMU None

0~4294967295 None None PMU None

0~4294967295 None None PMU None

0~18 characters None None PMU None

0~32 characters None None PMU None


Huawei, Emerson,
Holdluck-ZYT,
Power-One, Kehua,
DeltaElectronics,
EltekEnergy,
0~18 characters None None PMU None
Switchtec,
Avail_0, Avail_1,
TycoElectronics,
Avail_20,
ARTESYN, Avail_21, None None PMU None
Avail_500,
CHROMA,
Avail_501,
LuckyValley,
UNSUPPORTED,
Avail_504,
ACBEL, Zippy, None None PMU None
SUPPORTED
Avail_508,
GuoyaoElectronics,
Avail_509,
DPC, GoldPower,
DISABLE,
Avail_520,
Alarm_0, ENABLE
Alarm_1, None None PMU None
SungrowPowerSup
SUCCEEDED,
Avail_521,
Alarm_2,
ply, Ecom Alarm_3,
BRDNOTREADY,
Avail_524,
Alarm_4, Alarm_5,
UNSUPPORTED, None None PMU None
Avail_528,
Alarm_6, Alarm_7,
BATNOTEXIST,
Avail_529,
Alarm_8, Alarm_9,
INTERNALERR
Avail_800,
Alarm_10, None None PMU None
Avail_801,
Alarm_11,
Avail_820,
Alarm_12,
Enabled,
Alarm_13,Disabled
Avail_821, None None PMU None
Avail_c10,
Alarm_14,
Avail_c11,
Alarm_15 None None PMU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None PMU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None PMU None
Avail_c33,
Avail_c34,
0~31 characters None None PMU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None PMU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None PMU None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None PMU None
Avail_d29
0~19 characters None None PMU None
LMPT, LBBP, FAN,
UPEU, UTRP, None None PMU None
USCU, UEIU
0~4294967295 None None PMU None

CPU, DSP None None PMU None


-
2147483648~2147 None None PMU None
483647
-
2147483648~2147 None None PMU None
483647
0~255 characters None None PMU None
Master, NDD, NCD,
NDC, NEC, EUL, None None PMU None
EDL
CABINET,
SUBRACK,
None None PMU None
BOARD,
SUBBOARD, SFP
0~63 characters None None PMU None

0~63 characters None None PMU None

0~63 characters None None PMU None

0~63 characters None None PMU None

1~39 characters None None PMU None

Normal, Fault,
None None PMU None
Timeout, NULL

0~65535 None None PMU None

0~65535 None None PMU None

0~62 0 0 DieselGen None

7 7 7 DieselGen None

0 0 0 DieselGen None

DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) DieselGen None


1. The actual value
0.1~100.0, step:0.1 125 125 DieselGen of this parameter
None
for the SC48200
PMU MO ranges
1~7 characters None None DieselGen from
None54.2 V to 57.5
V. The actual value
of this parameter
-150.0~150.0 None None DieselGen None
for other types of
PMU MO ranges
0~4294967295 None None DieselGen from
None43.3 V to 57.6
V.
2. This parameter
0~62 0 0 Battery for
Nonethe SC48200
PMU MO should
meet the following
7 7 7 Battery None
requirements: BCV
The battery in the Battery MO
installation type of should not be
0 0 0 Battery None
the SC48200 PMU smaller
INSTALLTYPEthan FCVof in
Based on the PMU the Battery MO plus
is OUTER. The for
type: The 2.2 V.
INNER, OUTER INNER(Inner) battery installation Battery a SC48200 PMU
recommended 3. This parameter
type of other types MO must be set to
value for the not for the
of PMU should be OUTER.
30~240 60 APM30
60 is 30. The Battery None
SC48200 PMU MO
set based on the
recommended should meet the
actual situation. 1. The actual value
value for the following
43.3~57.6, step:0.1 565 565 Battery range of BC1 in a
APM100 is 100. requirements:
PMU MO otherBCVthan
The recommended in the Battery PMU
MO
the SC48200
value for the should be larger
5~5000 36 Battery is 5 to 5000.
APM200 is 200. than FCV in the
2. The actual value
The recommended Battery MO.
range of BC1 in the
value for the 4. This parameter
SC48200 PMU MO
PS4890 is 30. The not50fortothe
is 5000.
recommended SC48200 PMU MO
value for the should meet the
EPS4815 is 65. The following
recommended requirements: BCV
ranges from 52 V to
56.3 V. Theinactual
1. If LSDF PMU
valueequal
MO of FCV to for
other types of
"DISABLE" and PMU
MO
SDVranges
in Battery fromMO
43.2
equalVtoto"ENABLE",
57.5 V.
1.
2. The
FCV actual
in
SDV in Battery the valueMO
of SDT
Battery
must befor
MO the
smaller
0.05~0.25,
15 15 Battery None
SC48200
corresponding
than DCVLTHD PMUtoMO in
step:0.01
ranges
the from
SC48200
other PMU MO 45 PMUto
than
70.
MO The
minus
SC48200. actual1.5 V
43.2~57.5, step:0.1 535 535 Battery value of SDT forin
must be greater
2. If both LSDF
The recommended other
than or
PMU types
MO equalandof to
PMU
SDV the
DISABLE, ENABLE ENABLE(Enable) value of this
ENABLE(ENABLE) Battery MO
None
in ranges
smaller
Battery value from
MO equal 40
parameter for the to 70.
between 46.5
to "ENABLE", SDV V and
SC48200 PMU is 2. The value
DCVLTHD
in Battery MOin of
thethis
must
40~70 53 60. The Battery parameter
PMU MO
be smaller than for
plus the
0.5
The recommended
recommended SC48200
V. PMUPMU MO
LSDV in other
value of this should
3. FCV not be
DISABLE, ENABLE ENABLE(Enable) ENABLE(ENABLE) Battery MO
None thaninSC48200.
other
parameter for theother smaller
PMU MO than than
3.
1. This parameter
The actualinvalue
TLTHD the of
SC48200
types of PMUPMUisis53. TUTHD
SC48200 in should
the
460. The
for the
Battery
TCC MOthe must be
forSC48200 be
35.0~55.6, step:0.1 430 Battery Battery
greater
PMU MO
smaller MO
than
than plus 10.
should
recommended SC48200 PMU MO
3. Thisthe
DCVLTHD
meet
TUTHD. parameter
in0the
following is
value of this ranges from to
valid
PMU only
MO
requirements:
2. The actualwhen
minus SDV
value2
parameter for other 100. The actual
0~500 80 80 Battery HTSDF
V.
in
of Battery
TUTHD in MOthe
in must
the
types of PMU is value of this
Battery
TLTHD
be smaller
Battery MO
in
MO theis
than set
the to
of the
430. parameter for
ENABLE.
Battery
LSDV in the
SC48200 MO PMUmust
PMU MO be
-20~20 -19 -19 Battery other-type batteries
smaller
MO plus than
ranges from 35-0.5 V.
0 toto
TUTHD.
4.
60.The
500. Theactual
cabinet value
35~80 50 50 Battery of SDV for
number, the
subrack
SC48200and
number, PMU slotMO
ranges from
number of the 45 V to
1~2 1 1 Battery None
48 V. The
battery is theactualsame
value
as of SDV
those of thefor
VRLA_BAT(VRLA VRLA_BAT(VRLA other
VRLA_BAT, LI_BAT Battery None types
PMU. The actualof PMU
Battery) Battery) MO ranges
value of thisfrom 35
V to 55.3 V.for other
parameter
0~4294967295 None None Battery 5. Thisofparameter
types
None PMU MO is
valid only
ranges from when35 to
LVSDF in the
80.
0~4294967295 None None Battery None
Battery MO is set to
ENABLE.
0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None


0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None

0~4294967295 None None Battery None


Based on the PMU
type: The
0~4294967295 None None Battery None
recommended
value for the
0~4294967295 None APM30
None is 30. The Battery None
recommended
1. The actual value
2000-01-01~2099- value for the
None None Battery range
None of BC2 in a
12-31 APM100 is 100.
PMU MO other than
The recommended
the SC48200 PMU
value for the
5~5000 36 Battery is 5 to 5000.
APM200 is 200.
2. The actual value
The recommended
range of BC2 in the
0~62 0 value
0 for the BatCTPa None
SC48200 PMU MO
PS4890 is 30. The
is 50 to 5000.
recommended
7 7 7
value for the BatCTPa None
EPS4815 is 65. The
recommended
0 0 0 BatCTPa None
value for the
SC48200 is 1000.
0.01~50.00,
1200 1200 BatCTPa None
step:0.01
0.01~50.00,
600 600 BatCTPa None
step:0.01
0.01~50.00,
300 300 BatCTPa None
step:0.01
0.01~50.00,
150 150 BatCTPa None
step:0.01
0.01~50.00,
100 100 BatCTPa None
step:0.01
0.01~50.00,
70 70 BatCTPa None
step:0.01
0.01~50.00,
50 50 BatCTPa None
step:0.01
0.01~50.00,
40 40 BatCTPa None
step:0.01
0.01~50.00,
30 30 BatCTPa None
step:0.01
0.01~50.00,
25 25 BatCTPa None
step:0.01

80~100 80 80 BatCTPa None

1.70~2.20,
190 190 BatCTPa None
step:0.01

1~50 24 24 BatCTPa None

1~100 10 10 BatCTPa None

1~240 60 60 BatCTPa None

When ATMODE in
40.0~54.0, step:0.1 450 450 BatCTPa None
the BatCTPa MO is
NOAUTOTEST,
PERIOD, set to
POWERCUT(Powe POWERCUT(Powe When ATMODE in
PERIOD(Period
POWERCUT, BatCTPa None
the
PERIODPOWERC
r Off Auto Test) r Off Auto Test) Auto Test) or MO is
BatCTPa
set to
PERIODPOWERC
UT PERIOD(Period
30~240 120 120 BatCTPa UT(Period and
Auto
Power Test) or
Off Auto
PERIODPOWERC
Test), TDSTM in the
1~60 14 14 BatCTPa UT(Period
BatCTPa MO andmust
Power Off Auto
be greater than
STANDARD, Test), TDSTM
SIMPLE, TIMER, None None BatCTPa DDSTM
None in the in the
BatCTPa
BatCTPa MO.must
MO
PWROFF, NONE be greater than
2000-01-01
00:00:00~2038-12- None None BatCTPa DDSTM
None in the
BelowEndVol,
31 23:59:59 BatCTPa MO.
OverTime,
CurrRecover, None None BatCTPa None
ManualEnd,
AlmEnd
None, Normal,
None None BatCTPa None
PreAlm, Alm

0~100 None None BatCTPa None

1~7 characters None None BatCTPa None

-100.00~100.00 None None BatCTPa None

-150.0~150.0 None None BatCTPa None

0~4294967295 None None BatCTPa None


-
2147483648~2147 None None BatCTPa None
483647
0~62 0 0 PSU None

7 7 7 PSU None

1~6 1 None PSU None


Avail_0, Avail_1,
Avail_20, Avail_21,
NORMAL,
Avail_500,
Huawei, Emerson,
COMMUNICATEFAI
Avail_501,
Holdluck-ZYT,
LED, SHUTDOWN,
Avail_504, None None PSU None
Power-One,
FAULT, Kehua,
PROTECT,
Avail_508,
DeltaElectronics,
UNCONFIGURED,
Avail_509,
EltekEnergy,
ILLEGAL
0~18 characters None None PSU None
Avail_520,
Alarm_0,
Switchtec,Alarm_1,
Avail_521,
Alarm_2, Alarm_3,
TycoElectronics,
Avail_524,
Alarm_4, Alarm_5,
ARTESYN, None None PSU None
Avail_528,
Alarm_6,
CHROMA,Alarm_7,
Avail_529,
Alarm_8, Alarm_9,
LuckyValley,
Avail_800,
Alarm_10, None None PSU None
ACBEL, Zippy,
Avail_801,
Alarm_11,
GuoyaoElectronics,
Avail_820,
Alarm_12,
DPC, GoldPower,
Enabled, Disabled None None PSU None
Avail_821,
Alarm_13,
SungrowPowerSup
Avail_c10,
Alarm_14,
ply, Ecom
Avail_c11,
Alarm_15 None None PSU None
Avail_c12,
Avail_c13,
Avail_c14,
0~2047 characters None None PSU None
Avail_c30,
Avail_c31,
0~31 characters
Avail_c32, None None PSU None
Avail_c33,
Avail_c34,
0~31 characters None None PSU None
Avail_d00,
Avail_d01,
Avail_d04,
0~259 characters None None PSU None
Avail_d08,
Avail_d09,
0~11 characters
Avail_d20, None None PSU None
Avail_d21,
Avail_d24,
0~23 characters
Avail_d28, None None PSU None
Avail_d29
0~19 characters None None PSU None
LMPT, LBBP, FAN,
UPEU, UTRP, None None PSU None
USCU, UEIU
0~4294967295 None None PSU None

CPU, DSP None None PSU None


-
2147483648~2147 None None PSU None
483647
-
2147483648~2147 None None PSU None
483647
0~255 characters None None PSU None
Master, NDD, NCD,
NDC, NEC, EUL, None None PSU None
EDL
CABINET,
SUBRACK,
None None PSU None
BOARD,
SUBBOARD, SFP
0~63 characters None None PSU None

0~63 characters None None PSU None


0~63 characters None None PSU None

0~63 characters None None PSU None

1~39 characters None None PSU None

Normal, Fault,
None None PSU None
Timeout, NULL

0~65535 None None PSU None

0~65535 None None PSU None

0~62 0 0 OutPort None

40~59 40 40 OutPort None

0 0 0 OutPort None

0~5 None None OutPort None

0~50 characters None None OutPort None


1. PT must be set to
BOOL when the
OFF, ON OFF(Off) OFF(Off) OutPort None MO is
AlmPort
located on the EMU
0~62 None None AlmPort MO
None (the value of
subrack number of
the EMU ranges
0~1,7~8,11~12,14,4 from
None None AlmPort None40 to 59), the
0~254 value of PN ranges
from 0 to 31, and
0,18~19 None None AlmPort None
SW in the AlmPort
MO is set to ON.
When the AlmPort
0~35 None None AlmPort None
MO is located on
MOs other than the
OFF, ON OFF(Off) OFF(Off) AlmPort EMU,
None and SW in
the AlmPort MO is
set to ON, PT is set
65033~65233 65033 65033 AlmPort None
to BOOL only.
2. PT must be set to
VALUE when the
BOOL, VALUE BOOL(Digital Port) BOOL(Digital Port) AlmPort
AlmPort MO is
This parameter
located on the EMU is
valid
MO only when ofPT
HIGH, LOW LOW(Low Voltage) LOW(Low Voltage) AlmPort 1.
in UL(the
the in value
the
AlmPort AlmPort
MO
subrack
MO must number of
be greater
is
theset
EMUto BOOL.
ranges
-999.99~9999.99, than LL.
9900 9900 AlmPort from
LL 40 to
step:0.01 1. UL
2. in the59),
in the the
AlmPort
AlmPort
value
MO of
must PNbe
MO should not be ranges
smaller
-999.99~9999.99, from
than 32 than
UL.
greater to 35,SMUL.
and
100 100 AlmPort
step:0.01 SWLLinshould
2. the AlmPort
not be
MO is set
smaller thanto ON.
SMLL
VOLTAGE, VOLTAGE(Voltage VOLTAGE(Voltage 3.
in SMLL,
the SMUL,
AlmPort MO.
AlmPort None
CURRENT Type) Type) SOLL, SOUL, and
ST must exist when
SW and PT in the
AlmPort MO are set
to ON and VALUE
respectively. AVOL
must exist when
SW and PT are set
1. This parameter is
valid only when PT
in the AlmPort MO
is
1. set
SMLLto VALUE.
in the
2. SMULMO
AlmPort in the
must
-999.99~9999.99, AlmPort
be smallerMO must
than
10000 10000 AlmPort
step:0.01 be greater
SMUL. SMLLthan
1. This parameter in the
is
SMLL.
AlmPort
valid onlyMOwhenshould
PT
-999.99~9999.99, 3. SMUL in theMO
0 0 AlmPort notthe
in beAlmPort
greater than
step:0.01 AlmPort
1. This MO should
parameter is
LL.
is set to VALUE.
0~9999.99, not
valid
2. be
This smaller
only when
parameter
2. The output upper than
PTis
100 100 AlmPort UL.
in the
valid AlmPort
only when MOPT
step:0.01 limit SOUL in the
is
in set
the to
AlmPort VALUE.
AlmPort
MO must MO
0~9999.99, 2. The
is set
be output
to VALUE.
greater than lower
the
0 0 AlmPort
step:0.01 limit
outputSOLL
lowerin limit
the
AlmPort
SOLL. MO must
NONE, PEER NONE(Verify None) None SSL be
Nonesmaller than the
output upper limit
This parameter is
SOUL.
valid only when
Valid IP address 0.0.0.0 None NtpCp
MODE in the NtpCp
MO is IPV4.
1~525600 None 6 hours NtpCp None

123~5999,6100~65
123 None NtpCp None
534

OFF, ON ON(On) None NtpCp None


GMT-1200, GMT-
IPV4, GMT-1000,
1100, IPV6 IPV4(IPv4) None NtpCp None
GMT-0930, GMT- This parameter is
0900, GMT-0800, valid only when
Valid IP address
GMT-0700, GMT- 0:0:0:0:0:0:0:0 None NtpCp
MODE in the NtpCp
0600, GMT-0500,
PLAIN, DES_S, MO is IPV6.
GMT-0430, GMT-
DES_N, DES_A, PLAIN(Plain) None NtpCp None
0400,
MD5 GMT-0330, This parameter is
GMT-0300, GMT- valid when the
1~16 characters
0200, GMT-0100, None None NtpCp AUTHMODE
GMT, GMT+0100, This parameter
parameter is notisset
GMT+0200, valid
to PLAIN. the
when
1~4294967295
GMT+0300, None None NtpCp AUTHMODE
GMT+0330, parameter is not set
GMT+0400, to PLAIN.
Slaver, Master Slaver(Slave) None NtpCp None
GMT+0430,
GMT+0500, 1. This parameter is
GMT+0800(GMT+0
GMT+0530, None TZ Noneonly when
valid
8:00)
GMT+0545, DST in the TZ MO
GMT+0600, is
NO, YES, ALL NO(No) None TZ 1. set
Thistoparameter
None
YES and is
GMT+0630, SM isonly
set to
valid
This when is
parameter
GMT+0700, DATEWEEK
DATE, WEEK, DST
valid in the
only when TZorMO
GMT+0800, DATE(Date mode) None TZ DATE.
DATEWEEK is
DSTsetintotheYES TZandMO
GMT+0845, 2. If is
DST, SM, and
JAN, FEB, MAR, SM
is set set
to to
YES.
GMT+0900, SMONTH in the TZ
APR, MAY, JUN, DATEWEEK, DATE,
GMT+0930, JAN(January) None TZ MO are set to YES,
JUL, AUG, SEP, or WEEK.
GMT+1000, DATE, and
OCT, NOV, DEC 2. If DST in FEB
the TZ
GMT+1030, respectively, SDAY
1~31 1 None TZ MO is set to YES,
GMT+1100, cannot
This be greater
SMONTH must is
parameter
GMT+1130, than
LAST, FIRST, differ28.
valid only
fromwhen
GMT+1200, 3. If DST theandTZSM
SECOND, THIRD,
GMT+1245,
FIRST(First) None TZ DST
EMONTH. in
This parameter is in
MO
FOURTH the TZ
is set
valid toMO
only YES areand
when set
GMT+1300,
MON, TUE, WED, to
SMYES andTZ MO
isinWEEK.
GMT+1400, DST the
THU, FRI, SAT, MON(Monday) None TZ DATEWEEK
CUSTOM is set to YES and
SUN respectively,
This EDAY
SM isparameter
DATEWEEK is
must
valid
or WEEK. be
only setwhento a
00:00:00~23:59:59 00:00:00 None TZ
valueinless
DST thethan
TZ MO or
equal
is set to to YES.
the number
of days in SMONTH
minus six.
1. This parameter is
valid only when
DST in the TZ MO
is set to YES and
EM is set to
This parameter
DATEWEEK or is
DATE, WEEK, valid
DATE. only when
DATE(Date mode) None TZ This parameter is
DATEWEEK DST
2. in theEM,
If DST, TZ MO
JAN, FEB, MAR, valid
is set only
to whenand
YES.
APR, MAY, JUN, EMONTH
DST in theinTZ the
MO TZ
JAN(January) None TZ MO are set to YES,
JUL, AUG, SEP, is set to YES and
OCT, NOV, DEC DATE, and FEB
EM is DATEWEEK,
respectively,
DATE, or WEEK. EDAY
1~31 1 None TZ
cannot
This be greater
parameter is
LAST, FIRST, than
valid 28.
only when
SECOND, THIRD, FIRST(First) None TZ 3.
DSTIf DST
This in theand
parameter TZEM MOis in
FOURTH the
is TZ
set toMO YES
valid only when are set
and
MON, TUE, WED, to
EM YES andTZ MO
isinWEEK.
DST the
THU, FRI, SAT, MON(Monday) None TZ DATEWEEK
is set to YES and
SUN respectively,
This EDAY
EM isparameter
DATEWEEK is
must
valid be
only
or WEEK. set to
when a
00:00:00~23:59:59 00:00:00 None TZ
value
DST inless
thethan
This parameter TZ MO or
is
equal
is to YES.
setonly
valid to the number
when
-120~120 0 None TZ of days
DST in thein EMONTH
TZ MO
This
is setparameter
minus YES or is
tosix.
valid
ALL. only when
-720~840 0 None TZ ZONET in the TZ
MO is set to
2000-01-01~2033- CUSTOM.
None None OmuCurTime None
12-31

00:00:00~23:59:59 None None OmuCurTime None

None None None OmuCurTime None

NTP, GPS, NONE NTP(NTP) None TimeSrc None

0~30 characters None None TimeSrc None

CnOperatorExtende
0~3 None None None
dQci
CnOperatorExtende
10~254 None None None
dQci
CnOperatorExtende
0~9 0 None None
dQci
CnOperatorStandar
0~3 None None None
dQci
QCI1, QCI2, QCI3,
CnOperatorStandar 1. In the
QCI4, QCI5, QCI6, None None None
CSFallBackBlindHo
dQci
QCI7, QCI8, QCI9 Cfg MO,
1. In
In the
CnOperatorStandar 1. the
InterRatHighestPri
CSFallBackBlindHo
0~9 0 None None
CSFallBackBlindHo
dQci must
Cfg be different
MO,
Cfg
from MO,
InterRatHighestPri
CSFallBackBlindHo InterRatLowestPri
0~3 None None InterRatSecondPri.
None be different
must
Cfg must
2. be set to
In the
from
NULL if
UTRAN, GERAN, CSFallBackBlindHo CSFallBackBlindHo
InterRatLowestPri.
InterRatSecondPri
UTRAN UTRAN Cfg
CDMA2000 Cfg 2.
is InMO,
setthe
to NULL.
InterRatSecondPri
CSFallBackBlindHo
UTRAN, GERAN, 2. In
CSFallBackBlindHo must the
be different
GERAN GERAN Cfg MO,
CSFallBackBlindHo
CDMA2000, NULL Cfg from
InterRatHighestPri
Cfg MO,
InterRatLowestPri
UTRAN, GERAN, CSFallBackBlindHo must be different if
InterRatSecondPri
CDMA2000 CDMA2000 InterRatSecondPri
from
CDMA2000, NULL Cfg must
is not be
setdifferent
to NULL.
InterRatSecondPri.
from
3. In the
InterRatLowestPri
CSFallBackBlindHoif
InterRatSecondPri
Cfg MO,
is not set to NULL.
InterRatLowestPri
3. In the
must be set to
CSFallBackBlindHo
NULL if
Cfg MO,
InterRatSecondPri
CSFallBackBlindHo
OFF, ON OFF(Off) OFF(Off) None
Cfg
CSFallBackBlindHo
OFF, ON OFF(Off) OFF(Off) None
Cfg
CSFallBackBlindHo
OFF, ON OFF(Off) OFF(Off) None
Cfg
Among
RatFreqPriorityGrou RatFreqPriorityGrou
0~255 None None None
p 1. Among
p MOs with
RatFreqPriorityGrou
RatType of UTRAN
LTE, UTRAN, RatFreqPriorityGrou p MOs with
None None or GERAN, only
GERAN p RatType of UTRAN
one Priority can be
0~39649,65336~65 RatFreqPriorityGrou or GERAN,
mapped only
to one
None None None
one Priority can be
RatFreqPriorityGrou
535 p
mapped
pId. to one
RatFreqPriorityGrou RatFreqPriorityGrou
0~7 0 None
p pId.
2. Among
ServiceIrHoCfgGro RatFreqPriorityGrou
0~3 None None None
up p MOs, Priority
ServiceIrHoCfgGro must be unique for
0~9 None None None
each
up
RatFreqPriorityGrou
NO_HO,
ServiceIrHoCfgGro pId.
PERMIT_HO, NO_HO None None
up
MUST_HO
1~256 None None SpidCfg None

FALSE, TRUE FALSE(FALSE) None SpidCfg None

NOT_CFG(NOT_C
NOT_CFG, CFG None SpidCfg None
FG)

0~255 0 None SpidCfg None

0,10~600 0 0 CounterCheckPara None

0,128~4294967295 0 0 CounterCheckPara None


In the
ENodeBCipherCap
OFF, ON OFF(Off) OFF(Off) CounterCheckPara None
MO, the
In the
PrimaryCipherAlgo,
NULL, Snow3G, NULL(NULL NULL(NULL ENodeBCipherCap
SecondCipherAlgo,
ENodeBCipherCap MO, the
AES Algorithm) Algorithm) and
In the
PrimaryCipherAlgo,
ThirdCipherAlgo
NULL, Snow3G, AES(AES AES(AES ENodeBCipherCap
SecondCipherAlgo,
ENodeBCipherCap parameters
MO,
In thethe
must be
AES Algorithm) Algorithm) and
set to different
PrimaryCipherAlgo,
ENodeBIntegrityCa
ThirdCipherAlgo
NULL, Snow3G, Snow3G(SNOW 3G Snow3G(SNOW 3G values.
SecondCipherAlgo,
ENodeBCipherCap p MO, the must be
parameters
In the
AES Algorithm) Algorithm) and
PrimaryIntegrityAlg
set to different
ENodeBIntegrityCa
ThirdCipherAlgo
o,
NULL, Snow3G, NULL(NULL NULL(NULL ENodeBIntegrityCa values.
p MO, the must be
parameters
SecondIntegrityAlg
In the
AES Algorithm) Algorithm) p PrimaryIntegrityAlg
set to different
o, and
ENodeBIntegrityCa
o,
values.
NULL, Snow3G, AES(AES AES(AES ENodeBIntegrityCa ThirdIntegrityAlgo
p MO, the
SecondIntegrityAlg
parameters must be
AES Algorithm) Algorithm) p PrimaryIntegrityAlg
o,
setand
to different
o,
NULL, Snow3G, Snow3G(SNOW 3G Snow3G(SNOW 3G ENodeBIntegrityCa ThirdIntegrityAlgo
values.
SecondIntegrityAlg
parameters must be
AES Algorithm) Algorithm) p
o,
setand
to different
ThirdIntegrityAlgo
values.
parameters must be
set to different
values.
X2_OVER_M2000( X2_OVER_M2000(
X2_OVER_M2000,
X2SonLink is set up X2SonLink is set up GlobalProcSwitch None
X2_OVER_S1
over M2000) over M2000)
OFF, ON ON(On) ON(On) GlobalProcSwitch None

LCG_PROFILE_0, LCG_PROFILE_0(L LCG_PROFILE_0(L


GlobalProcSwitch None
LCG_PROFILE_1 CG_PROFILE_0) CG_PROFILE_0)

OFF, ON OFF(Off) OFF(Off) PdcpRohcPara None


U_MODE,
U_MODE(Unidirecti U_MODE(Unidirecti
O_MODE, PdcpRohcPara None
onal Mode) onal Mode)
R_MODE
Profile0x0001, Profile0x0001:on, Profile0x0001: on;
Profile0x0002, Profile0x0002:on, Profile0x0002: on;
PdcpRohcPara None
Profile0x0003, Profile0x0003:on, Profile0x0003: on;
Profile0x0004 Profile0x0004:on Profile0x0004: on
1~16 4 4 RrcConnStateTimer None
min5, min10,
min20, min30,
min10(10) min10(10) RrcConnStateTimer None
min60, min120,
ms50,
min180ms100,
ms150, ms200,
ms500(500) ms500(500) RrcConnStateTimer None
ms500, ms1000,
ms100,
ms2000ms200,
ms500, ms1000,
ms8000(8000) ms8000(8000) RrcConnStateTimer None
ms2000, ms4000,
min5,
ms8000 min10,
min20, min30,
min120(120) min120(120) RrcConnStateTimer None
min60, min120,
min180
0~3600 1800 1800 RrcConnStateTimer None

2000~60000 5000 None RRSTATETIMER None

2000~60000 15000 None RRSTATETIMER None

2000~60000 15000 None RRSTATETIMER None

2000~60000 20000 None RRSTATETIMER None

0,2000~60000 5000 None RRSTATETIMER None

5~3600 10 None RRSTATETIMER None

0~11 None None CellDlpcPdschPa None

DB_6_P_A, When the


OFF, ON
DB_4DOT77_P_A, OFF(Off) OFF(Off) CellDlpcPdschPa None
PdschPcSwitch and
DB_3_P_A, Dual-antenna or DlIcicAlgoSwitch
DB_1DOT77_P_A, four-antenna: -3 dB are off, the PDSCH
DB_3_P_A(-3 dB) CellDlpcPdschPa
DB0_P_A, Single antenna: 0 uses the fixed
DB1_P_A, dB power. The PA is
DB2_P_A,
0~11 None None CellDrxPara set
In aby
None this
CellDrxPara
DB3_P_A pararmeter.
MO, the value of
FddEnterDrxThd
0~1, step:0.001 300 300 CellDrxPara
must be smaller
than that of
FddExitDrxThd.
PSF6(6 subframes)
PSF6(6 subframes)
QCI 1-TDD-
QCI 1-TDD-
Configuration
Configuration 4:
4:
PSF8(8
PSF8(8 subframes)
subframes)
QCI 1-TDD-
QCI 1-TDD-
Configuration 5:
Configuration 5:
In a CellDrxPara
PSF8(8 subframes)
PSF10(10 MO, the value of
QCI 1-TDD-
subframes) FddEnterDrxThd
0~1, step:0.001 800 800
Configuration
QCI 1-TDD- 6: CellDrxPara In a CellDrxPara
must be smaller
PSF5(5 subframes)
Configuration 6: MO,
than the
thatvalue
of of
QCI 4-FDD
PSF3(3 subframes) TddEnterDrxThdUl
0~2, step:0.001 300 300 CellDrxPara FddExitDrxThd.
In a CellDrxPara
: PSF2(2
QCI 4-FDD must be smaller
subframes)
: PSF4(4 MO,
than the
thatvalue
of of
QCI TddEnterDrxThdUl
0~2, step:0.001 800 800 4-TDD-
subframes) CellDrxPara TddExitDrxThdUl.
In a CellDrxPara
Configuration
QCI 4-TDD- 0: must be smaller
MO,
than the
thatvalue
of of
PSF2(2 subframes)
Configuration 0: TddEnterDrxThdDl
TddExitDrxThdUl.
0~2, step:0.001 300 QCI
300 4-TDD-
PSF4(4 subframes) CellDrxPara In a CellDrxPara
must be smaller
Configuration
QCI 4-TDD- 1: MO,
than the
thatvalue
of of
PSF2(2 subframes)
Configuration 1: TddEnterDrxThdDl
0~2, step:0.001 800 800 CellDrxPara TddExitDrxThdDl.
QCI 4-TDD-
PSF4(4 subframes) must be smaller
UU_FC0_FILTER_ Configuration
QCI 4-TDD- 2: than that of
COEFF,
40~6000, step:20 30 PSF4(4
30 subframes)
Configuration 2: CellDrxPara TddExitDrxThdDl.
None
UU_FC1_FILTER_ QCI 4-TDD-
PSF5(5 subframes)
COEFF, Configuration
QCI 4-TDD- 3:
0~11
UU_FC2_FILTER_ None PSF4(4
None subframes)
Configuration 3: CellUlpcDedic None
COEFF, QCI 4-TDD-
PSF6(6 subframes)
UU_DISABLE,
UU_FC3_FILTER_ UU_DISABLE(Disa Configuration
QCI 4-TDD- 4:
UU_DISABLE(Disa
PSF4(4 subframes)
Configuration 4: CellUlpcDedic None
UU_ENABLE
COEFF, ble) ble)
-10.5,-9,-7.5,-6,-
UU_FC4_FILTER_ QCI 4-TDD-
PSF8(8 subframes)
4.5,-3,- Configuration
COEFF, -30 -30 4-TDD- 5:
QCI CellUlpcDedic None
1.5,0,1.5,3,4.5,6,7.5
UU_FC5_FILTER_ PSF4(4 subframes)
Configuration 5:
,9,10.5,12
-3,-2,-
COEFF, QCI 4-TDD-
PSF10(10
1,0,1,2,3,4,5,6,7,8,9
UU_FC6_FILTER_ -30 Configuration
-30
subframes) 6: CellUlpcDedic None
,10,11,12
COEFF, PSF2(2 subframes)
QCI 4-TDD-
UU_FC6_FILTER_ UU_FC6_FILTER_
QCI 6-FDD 6:
Configuration
UU_FC7_FILTER_
COEFF(UU_FC6_F COEFF(UU_FC6_F
: PSF2(2
PSF4(4 subframes) CellUlpcDedic None
COEFF,
ILTER_COEFF) ILTER_COEFF)
subframes)
QCI 6-FDD
UU_FC8_FILTER_ 1. This parameter is
COEFF, QCI 6-TDD-
: PSF3(3
0~11 None None DrxParaGroup None when
invalid
UU_FC9_FILTER_ Configuration
subframes) 0:
QCI 1: ON(On) EnterDrxSwitch is
COEFF, PSF2(2
QCI subframes)
6-TDD-
QCI 2: OFF(Off) set to OFF.
0~9
UU_FC11_FILTER_ None QCI
None6-TDD-
Configuration 0: DrxParaGroup None
QCI 3: OFF(Off) 2. In a
COEFF, Configuration
PSF3(3 1:
subframes)
QCI DrxParaGroup MO,
UU_FC13_FILTER_
PSF1, PSF2, PSF3, QCI 4:
PSF2(2 ON(On)
subframes)
6-TDD- the value of
OFF, ON OFF(Off) QCI
QCI 5: OFF(Off)
6-TDD-
Configuration 1: DrxParaGroup None
COEFF,
PSF4, PSF2,
PSF1, PSF5, PSF3,
PSF6, OnDurationTimer
QCI 6: ON(On)
Configuration
PSF3(3 2:
subframes)
UU_FC15_FILTER_
PSF8,
PSF4, PSF10,
PSF5, PSF6, cannot be larger
QCI 7:
PSF4(4
QCI OFF(Off)
subframes)
6-TDD-
COEFF,
PSF20, PSF30,
PSF8, PSF10, PSF2(2 subframes) DrxParaGroup than the value of
QCI
QCI 8: ON(On)2:
UU_FC17_FILTER_
PSF40, PSF30,
PSF20, PSF50, QCI 6-TDD-
Configuration
1: sf8(8 LongDrxCycle.
This parameter Ifis
QCI 9: ON(On)
Configuration
PSF5(5 3:
subframes)
COEFF,
PSF60, PSF50,
PSF40, PSF80, subframes) SupportShortDrx
invalid when is
UU_FC19_FILTER_ PSF3(3 subframes) PSF4(4
QCI 4:
QCI subframes)
6-TDD-
sf8(8 DrxParaGroup
PSF100,PSF80,
PSF60, PSF200 setThis
1. to parameter
EnterDrxSwitch is is
COEFF QCI
QCI 6-TDD-
1:
1: SF20(20
Configuration
subframes) 3: This
PSF100, PSF200, Configuration set toparameter
UU_ENABLE,
invalid when the
OFF. is
sf1,
SF10,sf2,
PSF300, sf4,
SF20, sf6,
SF32,
PSF500, QCI 6: sf8(8 4:
subframes)
PSF6(6 subframes)
UU_DISABLE(Disa invalid
value when
of
EnterDrxSwitch is
sf8(8 subframes) PSF4(4
QCI
ble) 4: subframes)
SF20(20
6-TDD- DrxParaGroup
sf8,
SF40,sf16,
PSF750, sf24,
SF64, sf33
SF80,
PSF1280, subframes) EnterDrxSwitch
OnDurationTimer
set to OFF. is
QCI 6-TDD-
subframes)
Configuration
QCI 8: sf8(8 4:
4: set
1. to
ThisOFF.
SF128,
PSF1920, SF160,
PSF2560 2. In a be larger is
cannot parameter
SF40(40 Configuration
QCI 6: SF40(40
PSF8(8 5:
subframes)
UU_ENABLE(Enabl
subframes) invalid when
SF256, SF320, DrxParaGroup than the value of
DrxParaGroup MO,
subframes) PSF4(4
e) subframes)
subframes)
QCI 6-TDD-
QCI 9: sf8(8 EnterDrxSwitch is
SF512, SF640, ShortDrxCycle.
the value of
This parameter is
QCI
QCI
QCI 6-TDD-
8:
4: SF40(40
Configuration
6: SF5(5 5:
subframes) set to OFF.
SF1024,
SF2, SF5,SF1280,
UU_DISABLE, SF8, UU_ENABLE(Enabl OnDurationTimer
invalid when
Configuration
subframes) 6:
subframes)
PSF10(10
UU_ENABLE(Enabl DrxParaGroup 2. In a be largeris
SF2048,
UU_ENABLE
SF10, SF16,SF2560
SF20, e) cannot
EnterDrxSwitch
PSF2(2
QCI 9: subframes)
6: SF40(40
subframes)
e)
QCI SF5(5 DrxParaGroup MO,
SF32, SF40, SF64, thantothe
set value of
OFF.
QCI 8-FDD
subframes)
6-TDD-
QCI 8:
subframes) the value of
SF80, SF128, SF5(5 subframes) DrxParaGroup LongDrxCycle.
: PSF2(2
Configuration
8: SF5(5 6:
UU_ENABLE(Enabl
QCI OnDurationTimer
SF160, SF256, subframes)
QCI4:2 This parameter
PSF3(3
e) subframes)
subframes) cannot be largeris
SF320, SF512, QCI
QCI 8-TDD-
QCI6:8
8-FDD
9: invalid when
1~16 8 QCI 9: SF5(5 DrxParaGroup than the value of
SF640 Configuration
QCI8:8 0: EnterDrxSwitch
: PSF3(3
UU_ENABLE(Enabl
subframes) ShortDrxCycle ifis
PSF2(2
QCI9:8 subframes)
subframes)
e) set to OFF.
QCI
QCI 8-TDD- InterRatHoCommGr SupportShortDrx is
0~11 None None8-TDD- None
set to
Configuration 0:
Configuration 1: oup
UU_ENABLE.
PSF2(2
PSF3(3 subframes)
subframes) InterRatHoCommGr
0~9 None None
QCI
QCI 8-TDD-
8-TDD- None
oup
Configuration
Configuration 2:
1:
PSF4(4 subframes)
PSF3(3 subframes)
QCI 8-TDD-
QCI 8-TDD-
Configuration
Configuration 3:
2:
PSF4(4
PSF5(5 subframes)
subframes)
QCI
QCI 8-TDD-
8-TDD-
Configuration 3:
Configuration 4:
PSF4(4 subframes)
1. The value of
0ms, 40ms, 64ms, InterRatHoCommGr InterRatHoA1ThdR
0~15
80ms, 100ms, 4 None None
srp must be larger
oup
128ms, 160ms, 1.
thanIn an
that of
256ms, 320ms, InterRatHoCommGr InterRatHoCommGr
InterRatHoA2ThdR
640ms None None
oup MO, the value
480ms, 512ms, oup srp.
1. The value of
of
640ms, 1024ms, 2. In an
1280ms, InterRatHoCommGr InterRatHoA2ThdR
InterRatHoA1ThdR
-141~-44 2560ms, -105 None InterRatHoCommGr
srp must be smaller
oup srq
5120ms oup
1.
thanInmust
MO,
an
that
be
the
of
larger
value
than
of or equal to
InterRatHoCommGr InterRatHoCommGr
InterRatHoA1ThdR
-20~-3, step:0.5 -20 None InterRatHoA2ThdR
InterRatHoA1ThdR
oup MO, the value
oup srp.
srq.
srp
of must be larger
2. In anvalue
InterRatHoCommGr 2.
thanTheor equal
InterRatHoA1ThdR ofto
-141~-44 -109 None InterRatHoCommGr
InterRatHoA1ThdR
oup InterRatHoA2ThdR
srq must
oup
srq MO, be
must thelarger
be value
larger
srp.
than or equal to
InterRatHoCommGr of
than that of
-20~-3, step:0.5 -24 None InterRatHoA2ThdR
InterRatHoA1ThdR
oup InterRatHoA2ThdR
srq.
srp must be larger
srq.
InterRatHoCdma1x 2.
thanTheorvalue
equalofto
0~11 None None None
InterRatHoA2ThdR
RttGroup InterRatHoA2ThdR
srq
srp.must be smaller
InterRatHoCdma1x than that of
0~9 None None None
RttGroup InterRatHoA1ThdR
If coverage-based
srq.
InterRatHoCdma1x handover is
0~15, step:0.5 2 None None
RttGroup enabled and the
0ms, 40ms, 64ms, threshold specified
InterRatHoCdma1x through this
-31.5~0,
80ms, step:0.5
100ms, -28 None None
RttGroup parameter is higher
128ms, 160ms,
256ms, 320ms, InterRatHoCdma1x than the associated
640ms None None
threshold for
480ms, 512ms, RttGroup
640ms, 1024ms, coverage-based
1280ms, 2560ms, InterRatHoCdma1x inter-RAT handover,
-31.5~0, step:0.5 -24 None
5120ms RttGroup coverage-based
handover takes
10~254 None None CellExtendedQci precedence
None over
both load- and
service-based
0~11 None None CellExtendedQci None
handovers. In this
case, load- and
service-based
0~9 0 None CellExtendedQci None
handovers will not
occur.
0~9 0 None CellExtendedQci None

0~9 0 None CellExtendedQci None

0~9 0 None CellExtendedQci None

0~9 0 None CellExtendedQci None

0~9 0 None CellExtendedQci None

0~9 0 None CellExtendedQci None

0~9 0 None CellExtendedQci None

0~11 None None CellStandardQci None


QCI1, QCI2, QCI3,
QCI4, QCI5, QCI6, None None CellStandardQci None
QCI7, QCI8, QCI9
0~9 0 None CellStandardQci None

0~9 0 None CellStandardQci None

0~9 0 None CellStandardQci None

0~9 0 None CellStandardQci None

0~9 0 None CellStandardQci None

0~9 0 None CellStandardQci None

0~9 0 None CellStandardQci None

0~9 0 None CellStandardQci None

ms5, ms10, ms20,


ms10(SRI 10ms) ms10(SRI 10ms) CellStandardQci None
ms40
InterRatHoCdmaHr
0~11 None None None
pdGroup
InterRatHoCdmaHr
0~9 None None None
pdGroup
If coverage-based
InterRatHoCdmaHr handover is
0~15, step:0.5 2 None None
pdGroup enabled and the
0ms, 40ms, 64ms, threshold specified
InterRatHoCdmaHr through this
-31.5~0,
80ms, step:0.5
100ms, -14 None None
pdGroup parameter is higher
128ms, 160ms,
256ms, 320ms, InterRatHoCdmaHr than the associated
640ms None None
threshold for
480ms, 512ms, pdGroup
640ms, 1024ms, coverage-based
1280ms, 2560ms, InterRatHoCdmaHr inter-RAT handover,
-31.5~0, step:0.5 -10 None
5120ms pdGroup coverage-based
handover takes
InterRatHoGeranGr precedence over
0~11 None None None
oup both load- and
InterRatHoGeranGr service-based
0~9 None None None
handovers. In this
oup If the threshold
case, load- and
specified through
InterRatHoGeranGr service-based
0~15, step:0.5 2 None None
this parameter is
oup handovers will not
higher
occur. than the
0ms, 40ms, 64ms, InterRatHoGeranGr associated
-110~-48
80ms, 100ms, -100 None None
threshold for the
oup
128ms, 160ms, coverage-based
256ms, 320ms, InterRatHoGeranGr inter-RAT handover
640ms 640ms None
480ms, 512ms, oup and the coverage-
640ms, 1024ms, based handover is
1280ms, InterRatHoGeranGr
-110~-48 2560ms, -98 None enabled, the
5120ms oup
coverage-based
InterRatHoUtranGro handover takes
0~11 None None None
precedence over
up
both the load- and
service-based
handovers. In this
case, the load- and
service-based
handovers would
not occur.
InterRatHoUtranGro
0~9 None None None
up
InterRatHoUtranGro
-24~0, step:0.5 -20 None None
up
If coverage-based
InterRatHoUtranGro handover is
-120~-25 -103 None None
up enabled and the
If coverage-based
threshold specified
0ms, 40ms, 64ms, InterRatHoUtranGro handover is
0~15, step:0.5
80ms, 100ms, 2 None through
None this
up enabled
parameter is the
and higher
128ms, 160ms, threshold specified
256ms, 320ms, than the
InterRatHoUtranGro through this associated
640ms None None
threshold for
480ms, 512ms, up parameter is higher
640ms, 1024ms, coverage-based
1280ms, 2560ms, InterRatHoUtranGro than the associated
inter-RAT handover,
-24~0, step:0.5 -18 None threshold for
5120ms up coverage-based
coverage-based
handover takes
InterRatHoUtranGro inter-RAT
precedence handover,
over
-120~-25 -101 None
up coverage-based
both load- and
handover
service-based takes
0~11 None None precedence
InterFreqHoGroup handovers.
None over
In this
both load-
case, load- andand
service-based
service-based
0~9 None None InterFreqHoGroup None
handovers. In this
handovers will not
case,
Theload-
occur.
1. valueandof
0ms, 40ms, 64ms, service-based
0~15, step:0.5
80ms, 100ms, 4 4 InterFreqHoGroup InterFreqHoA1Thd
None
handovers
Rsrp must be willlarger
not
128ms, 160ms, occur.
1. The value of
256ms, 320ms, than that of
640ms None InterFreqHoGroup InterFreqHoA1Thd
None
InterFreqHoA2Thd
480ms, 512ms, Rsrq must be larger
640ms, 1024ms, Rsrp.
1. The value
than
2. In that
an of of
1280ms,
-141~-44 2560ms, -105 None InterFreqHoA2Thd
InterFreqHoGroup InterFreqHoA2Thd
5120ms InterFreqHoGroup
Rsrp must be
Rsrq.
MO,
1. Thethevalue
valueofof
smaller
2. In an than that of
-20~-3, step:0.5 -20 None InterFreqHoA1Thd
InterFreqHoGroup InterFreqHoA2Thd
InterFreqHoA1Thd
InterFreqHoGroup
Rsrp
Rsrq must be larger
Rsrp.
MO, the valuethat
than
smaller
2. or equal
In an than toof of
-141~-44 -109 None InterFreqHoA1Thd
InterFreqHoGroup InterFreqHoA1Thd
InterFreqHoA2Thd
InterFreqHoGroup
Rsrq must be larger
Rsrp.
Rsrq.
MO, the value of
than
2. In an equal to
or
-20~-3, step:0.5 -24 None InterFreqHoGroup InterFreqHoA1Thd
InterFreqHoA2Thd
InterFreqHoGroup
Rsrp must be larger
Rsrq.
MO,
than the valuetoof
or equal
0~15, step:0.5 4 4 InterFreqHoA1Thd
InterFreqHoGroup InterFreqHoA2Thd
None
Rsrq
Rsrp.must be larger
than or equal to
-141~-44 -105 None InterFreqHoGroup InterFreqHoA2Thd
None
Rsrq.
0ms, 40ms, 64ms,
-20~-3,100ms,
80ms, step:0.5 -20 None InterFreqHoGroup None
128ms, 160ms,
256ms, 320ms,
640ms None InterFreqHoGroup None
480ms, 512ms,
640ms, 1024ms,
1280ms,
-141~-44 2560ms, -103 -103 InterFreqHoGroup None
5120ms

-20~-3, step:0.5 -18 -18 InterFreqHoGroup None

-141~-44 -85 None InterFreqHoGroup None

-20~-3, step:0.5 -16 None InterFreqHoGroup None


In an
-15~15, step:0.5 2 2 InterFreqHoGroup InterFreqHoGroup
None
MO, the value of
In an
A3InterFreqHoA1T
-141~-44 -95 -95 InterFreqHoGroup InterFreqHoGroup
hdRsrp must be
MO,
largerthe value
than of
or equal
A3InterFreqHoA1T
to that of
-141~-44 -99 -99 InterFreqHoGroup hdRsrp must be
A3InterFreqHoA2T
larger
hdRsrp. than or equal
to that of
0~11 None None IntraFreqHoGroup None
A3InterFreqHoA2T
hdRsrp.
0~9 None None IntraFreqHoGroup None

0~15, step:0.5 2 2 IntraFreqHoGroup None

0ms, 40ms, 64ms,


-15~15, step:0.5
80ms, 100ms, 2 2 IntraFreqHoGroup None
128ms, 160ms, 1. A maximum of
256ms, 320ms, one CnOperator
320ms 320ms IntraFreqHoGroup None
480ms, 512ms, MO with
640ms, 1024ms, CnOperatorType of
1280ms,
0~3 2560ms, None None CnOperator CNOPERATOR_PR
None
5120ms CnOperatorName
IMARY can be in
each CnOperator
configured for an
0~31 characters None None CnOperator MO must be
eNodeB.
CNOPERATOR_PR specified
2. Before and be
IMARY, unique.
configuring a
None None CnOperator
CNOPERATOR_SE CnOperator MO
CONDARY Each
with CnOperator
MO must contain of
CnOperatorType a
3 characters None None CnOperator
unique combination
CNOPERATOR_SE
Each
of MccCnOperator
and Mnc.
CONDARY,
MO must containensurea
2~3 characters None None CnOperator that the CnOperator
unique combination
MO withand Mnc.
of Mcc
CnOperatorType of
0~65535 None None CnOperatorTa None
CNOPERATOR_PR
Each CnOperatorTa
IMARY
MO must exists.
contain a
0~3 None None CnOperatorTa unique combination
Each CnOperatorTa
of CnOperatorId
MO
In must
the
and Tac. contain a
CnOperator
0~65535 None None CnOperatorTa unique
MO, if combination
of CnOperatorId is
CnOperatorType
and Tac.
set to
0~3 None None Emc
CNOPERATOR_PR
IMARY,
OFF, ON OFF(Off) None Emc CnOperatorId
None must
be set to 0.
This parameter is
valid when
OFF, ON OFF(Off) None Emc
EmcEnable is set to
This
ON. parameter is
valid when
1~15 1 1 Emc
EmcEnable is set to
This
ON. parameter is
valid when
1~15 1 1 Emc
EmcEnable is set to
INDEPENDENT, ON.
INDEPENDENT(Ind
SHARED_FREQ, ENodeBSharingMo
ependent Operator None None
SEPARATED_FRE de
Mode)
Q
LicenseSharingPoli
0~3 None None None
cy
The sum of
MaxUserNumRate
LicenseSharingPoli In
in all
the
1~100 None None
cy LicenseSharingPoli
S1ReestTimer MO,
cy
theMOs
valuecannot
of
1~300 1 None S1ReestTimer In the 100.
exceed
S1ReestMinTimer
S1ReestTimer
must be smallerMO,
the
thanvalue of
that of
1~300 300 None S1ReestTimer S1ReestMinTimer
S1ReestMaxTimer.
must be smaller
than that of
0~15 None None S1Interface None
S1ReestMaxTimer.
S1SctpLinkId in
each S1Interface
0~47 None None S1Interface
MO must have a
unique value.
0~3 None None S1Interface None

Release_R8, Release_R8(Releas
None S1Interface None
Release_R9 e_R8)

FALSE, TRUE FALSE(FALSE) None S1Interface None

Normal, Abnormal None None S1Interface None

Normal, Abnormal None None S1Interface None

FALSE, TRUE,
None None S1Interface None
NULL

0~3600 None None S1Interface None

0~100 None None S1Interface None

0~150 characters None None S1Interface None

0~224 characters None None S1Interface None

0~300 characters None None S1Interface None

0~255 None None S1Interface None

16~47 None None X2Interface None


The X2SctpLinkId
in each X2Interface
0~47 None None X2Interface
MO must be
unique.
0~3 None None X2Interface None

Release_R8, Release_R9(Releas
None X2Interface None
Release_R9 e_R9)
FORBID_AUTO_R
FORBID_AUTO_R FORBID_AUTO_R
MV,
MV(Forbid Auto MV(Forbid Auto X2Interface None
PERMIT_AUTO_R
Remove) Remove)
MV
0~50 characters None None X2Interface None
0~50 characters None None X2Interface None

Normal, Abnormal None None X2Interface None


1. In the Drx MO,
OFF, ON OFF(Off) OFF(Off) Drx None
the value of
OnDurationTimerSp
In
eciathecannot
Drx MO,be the
SF10, SF20, SF32,
OFF, ON ON(On) ON(On) Drx None
value of
larger than the
SF40, SF64, SF80,
OnDurationTimerSp
value of
SF128, SF160,
PSF1, SF10(10 SF10(10 ecial cannot be
SF256,PSF2, PSF3,
SF320, Drx ShortDrxCycleSpeci
PSF4,
PSF1, PSF5, PSF6, subframes) subframes) larger
al if than the
SF512,PSF2, PSF3,
SF640,
PSF8,
PSF4, PSF10,
PSF5, PSF6, value of
SupportShortDrxSp
SF1024, SF1280,
PSF20,
PSF8, PSF30,
PSF10, PSF4(4 subframes) PSF4(4 subframes) Drx LongDrxCycleSpeci
ecial is set to
SF2048, SF2560
PSF40,
PSF20, PSF50,
PSF30, al.
UU_ENABLE.
PSF60,
PSF40, PSF80,
PSF50, 2. In the Drx MO,
PSF100, PSF200 PSF5(5 subframes) PSF5(5 subframes) Drx None
thethe
In value
Drxof
MO, the
PSF60, PSF80,
PSF100, PSF200, OnDurationTimerSp
value of
UU_DISABLE, UU_DISABLE(Disa UU_DISABLE(Disa ecial
SF2, SF5,PSF500,
PSF300, SF8, Drx Nonecannot be
OnDurationTimerSp
UU_ENABLE
SF10, SF16,
PSF750, SF20,
PSF1280, ble) ble) larger than the
ecia cannot be
SF32, SF40,
PSF1920, SF64,
PSF2560 value of
larger than the
SF10(10 SF10(10
SF80, SF128, Drx LongDrxCycleSpeci
value of
subframes) subframes)
SF160, SF256, al.
ShortDrxCycleSpeci
SF320, SF512, al if
1~16 1 IMS
1 signaling: Drx None
SF640 SupportShortDrxSp
IMSSignalling(IMS
ecial is set to
Signalling)
10~254 None None ExtendedQci UU_ENABLE.
None
Low-delay service:
IMSSignalling, LowDelay(Low
TCPorBuffStreamin
LowDelay, Delay)
MinGbrRate_0_KB, g(TCP Based or IMS ExtendedQci None
TCPorBuffStreamin TCP signaling:
service or1000
non-
MinGbrRate_1_KB, Buffered Streaming) Low-delay service:
g real-time streaming
MinGbrRate_2_KB, 900
0.001~1, step:0.001 700
MinGbrRate_0_KB, service:
IMS signaling: ExtendedQci None
MinGbrRate_4KB, TCP service or1000
TCPorBuffStreaminnon-
MinGbrRate_1_KB,
MinGbrRate_8_KB, Low-delay service:
real-time
g(TCP streaming
Based or
MinGbrRate_2_KB,
MinGbrRate_16_K 900
0.001~1, step:0.001 700 service:
Buffered 700
Streaming) ExtendedQci None
MinGbrRate_4KB,
B, TCP service or non-
MinGbrRate_8_KB,
MinGbrRate_32_K real-time streaming
MinGbrRate_16_K MinGbrRate_1_KB( MinGbrRate_1_KB(
service: 700
B, ExtendedQci None
B, 1KB/s) 1KB/s)
MinGbrRate_64_K
MinGbrRate_32_K
B, MinGbrRate_1_KB( MinGbrRate_1_KB(
B,
MinGbrRate_128_K 1KB/s) ExtendedQci None
1KB/s)
MinGbrRate_64_K
B,
B,
MinGbrRate_256_K
0~1, step:0.1
MinGbrRate_128_K 10 10 ExtendedQci None
B,
B,
MinGbrRate_512_K
PBR_0_KBps,
MinGbrRate_256_K
B
0~39 0 None ExtendedQci None
PBR_8_KBps,
B,
PBR_16_KBps,
MinGbrRate_512_K
PBR_32_KBps, PBR_64_KBps(64K PBR_64_KBps(64K
B ExtendedQci None
PBR_64_KBps, B/s) B/s)
PBR_128_KBps,
PBR_256_KBps,
9~16 11 11 ExtendedQci None
PBR_INFINITY

0~39 5 None ExtendedQci None

PAID_USER, PAID_USER(Paid PAID_USER(Paid


ExtendedQci None
FREE_USER User) User)
InterRatPolicyCfgGr
0~39 None None None
oup
PS_HO:On, InterRatPolicyCfgGr
PS_HO, SRVCC None None
SRVCC:On oup
InterRatPolicyCfgGr
SRVCC SRVCC:On None None
oup
PS_HO:On,
PS_HO,
NACC_HO:Off, InterRatPolicyCfgGr
NACC_HO, None None
NON_NACC_HO:O oup
NON_NACC_HO LOFD-001021:PS
ff
CDMA1XRTTHoSw InterRatPolicyCfgGr Inter-RAT Mobility
SRVCC None
itch:On oup between E-UTRAN
and CDMA2000
OPT_HO, OPT_HO:On, InterRatPolicyCfgGr
None None
NON_OPT_HO NON_OPT_HO:Off oup
PERMIT_HO_ENU
M, PERMIT_HO_ENU InterRatPolicyCfgGr
None None
FORBID_HO_ENU M(Permit Ho) oup
PERMIT_FAST_AN
M
R_MEAS_ENUM,
Tpollretrans_m5, PERMIT_FAST_AN InterRatPolicyCfgGr
None None
FORBID_FAST_AN
Tpollretrans_m10,
DiscardTimer_50, R_MEAS_ENUM oup
R_MEAS_ENUM
Tpollretrans_m15,
DiscardTimer_100,
Tpollretrans_m5,
0~39
Tpollretrans_m20,
DiscardTimer_150, None None RlcPdcpParaGroup None
Maxretx_Threshold
Tpollretrans_m10,
Tpollretrans_m25,
DiscardTimer_300,
_t1,
Tpollretrans_m15,
Tstatprohibit_m0,
Tpollretrans_m30,
DiscardTimer_500, DiscardTimer_1500
Maxretx_Threshold
Tpollretrans_m20,
Tstatprohibit_m5, None RlcPdcpParaGroup None
Tpollretrans_m35,
DiscardTimer_750,
Maxretx_Threshold
_t2, (1500 ms)
Tpollretrans_m25,
Tstatprohibit_m10,
Tpollretrans_m40,
DiscardTimer_1500
_t1,
Maxretx_Threshold
Tstatprohibit_m0,
Tpollretrans_m30,
RlcMode_AM,
Tstatprohibit_m15, RlcMode_AM(Ackn
Tpollretrans_m45,
,_t3,
Maxretx_Threshold None RlcPdcpParaGroup None
Tstatprohibit_m5,
Tpollretrans_m35,
RlcMode_UM
Tstatprohibit_m20, owledge Mode)
Tpollretrans_m50,
DiscardTimer_Infinit
_t2,
PollByte_kb25,
Maxretx_Threshold This parameter is
Tstatprohibit_m10,
Tpollretrans_m40,
Tstatprohibit_m25,
Tpollretrans_m55,
y_t4,
Maxretx_Threshold
PollByte_kb50, Maxretx_Threshold valid when RlcMode
Tstatprohibit_m15,
Tpollretrans_m45,
Tstatprohibit_m30, None RlcPdcpParaGroup
Tpollretrans_m60,
_t3,
PollByte_kb75,
Maxretx_Threshold _t8(8) is set to
Tstatprohibit_m20,
Tpollretrans_m50,
Tstatprohibit_m35,
PollByte_kb25,
Tpollretrans_m65,
Maxretx_Threshold
PollByte_kb100,
_t6, This parameter is
RlcMode_AM.
Tstatprohibit_m25,
Tpollretrans_m55,
Tstatprohibit_m40,
PollByte_kb50,
Tpollretrans_m70,
_t4,
PollByte_kb125,
Maxretx_Threshold Maxretx_Threshold valid when RlcMode
Tstatprohibit_m30,
Tpollretrans_m60,
Tstatprohibit_m45,
PollByte_kb75, None RlcPdcpParaGroup
Tpollretrans_m75,
Maxretx_Threshold
PollByte_kb250,
_t8, _t8(8) is set to
Tstatprohibit_m35,
Tpollretrans_m65,
Tstatprohibit_m50,
PollByte_kb100, This parameter is
Tpollretrans_m80,
_t6,
PollByte_kb375,
Maxretx_Threshold RlcMode_AM.
Tstatprohibit_m40,
Tpollretrans_m70,
Tstatprohibit_m55,
PollByte_kb125, PollByte_kb25(25 valid when RlcMode
Tpollretrans_m85,
Maxretx_Threshold
PollByte_kb500,
_t16, None RlcPdcpParaGroup
Tstatprohibit_m45,
Tpollretrans_m75,
Tstatprohibit_m60,
PollByte_kb250, kBytes) is set to
Tpollretrans_m90,
_t8,
PollByte_kb750,
Maxretx_Threshold
Tstatprohibit_m50,
Tpollretrans_m80,
Tstatprohibit_m65, This parameter is
RlcMode_AM.
PollByte_kb375,
Tpollretrans_m95,
Maxretx_Threshold
PollPdu_p4,
PollByte_kb1000,
_t32
Tstatprohibit_m55,
Tpollretrans_m85,
Tstatprohibit_m70, PollByte_kb25(25 valid when RlcMode
PollByte_kb500,
Tpollretrans_m100,
_t16,
PollPdu_p8,
PollByte_kb1250, None RlcPdcpParaGroup
Tstatprohibit_m60,
Tpollretrans_m90,
Tstatprohibit_m75, kBytes) is set to
PollByte_kb750,
Tpollretrans_m105,
Maxretx_Threshold
PollPdu_p16,
PollByte_kb1500, This parameter is
Tstatprohibit_m65,
Tpollretrans_m95,
PollPdu_p4,
Tstatprohibit_m80, RlcMode_AM.
PollByte_kb1000,
Tpollretrans_m110,
_t32
PollPdu_p32,
PollByte_kb2000, PollPdu_p32(32 valid when RlcMode
Tstatprohibit_m70,
Tpollretrans_m100,
PollPdu_p8,
Tstatprohibit_m85,
PollByte_kb1250, None RlcPdcpParaGroup
Tpollretrans_m115,
PollPdu_p64,
PollByte_kb3000, PDUs) is set to
Tstatprohibit_m75,
Tpollretrans_m105,
Treordering_m0,
PollPdu_p16,
Tstatprohibit_m90,
PollByte_kb1500, This parameter is
Tpollretrans_m120,
PollPdu_p128,
PollByte_infinity RlcMode_AM.
Tstatprohibit_m80,
Tpollretrans_m110,
Treordering_m5,
PollPdu_p32,
Tstatprohibit_m95,
PollByte_kb2000, PollPdu_p32(32 valid when RlcMode
Tpollretrans_m125,
PollPdu_p256, None RlcPdcpParaGroup
Tstatprohibit_m85,
Tpollretrans_m115,
Treordering_m10,
PollPdu_p64,
Tstatprohibit_m100,
PollByte_kb3000, PDUs) is set to
Tpollretrans_m130,
PollPdu_Infinity
Treordering_m0,
Tstatprohibit_m90,
Tpollretrans_m120,
Treordering_m15,
PollPdu_p128,
Tstatprohibit_m105, This parameter is
RlcMode_AM.
PollByte_infinity
Tpollretrans_m135,
Treordering_m5,
Tstatprohibit_m95,
Tpollretrans_m125,
Treordering_m20,
PollPdu_p256,
Tstatprohibit_m110, Tpollretrans_m40(4 valid when RlcMode
Tpollretrans_m140,
Treordering_m10, None RlcPdcpParaGroup
Tstatprohibit_m100,
Tpollretrans_m130,
Treordering_m25,
PollPdu_Infinity
Tstatprohibit_m115, 0ms) is set to
Tpollretrans_m145,
Treordering_m15, This parameter is
Tstatprohibit_m105,
Tpollretrans_m135,
Treordering_m30,
Tstatprohibit_m120, RlcMode_AM.
Tpollretrans_m150,
Treordering_m20, Tpollretrans_m50(5 valid when RlcMode
Tstatprohibit_m110,
Tpollretrans_m140,
Treordering_m35,
Tstatprohibit_m125, None RlcPdcpParaGroup
Tpollretrans_m155,
Treordering_m25, 0ms) is set to
Tstatprohibit_m115,
Tpollretrans_m145,
Treordering_m40,
Tstatprohibit_m130, This parameter is
Tpollretrans_m160,
Treordering_m30, RlcMode_AM.
Tstatprohibit_m120,
Tpollretrans_m150,
Treordering_m45,
Tstatprohibit_m135, Tstatprohibit_m50(5 valid when RlcMode
Tpollretrans_m165,
Treordering_m35, None RlcPdcpParaGroup
Tstatprohibit_m125,
Tpollretrans_m155,
Treordering_m50,
Tstatprohibit_m140, 0ms) is set to
Tpollretrans_m170,
Treordering_m40,
Tstatprohibit_m130,
Tpollretrans_m160,
Treordering_m55,
Tstatprohibit_m145, This parameter is
RlcMode_AM.
Tpollretrans_m175,
Treordering_m45,
Tstatprohibit_m135,
Tpollretrans_m165,
Treordering_m60,
Tstatprohibit_m150, Tstatprohibit_m40(4 valid when RlcMode
Tpollretrans_m180,
Treordering_m50, None RlcPdcpParaGroup
Tstatprohibit_m140,
Tpollretrans_m170,
Treordering_m65,
Tstatprohibit_m155, 0ms) is set to
Tpollretrans_m185,
Treordering_m55, This parameter is
Tstatprohibit_m145,
Tpollretrans_m175,
Treordering_m70,
Tstatprohibit_m160, RlcMode_AM.
Tpollretrans_m190,
Treordering_m60, Treordering_m50(5 valid when RlcMode
Tstatprohibit_m150,
Tpollretrans_m180,
Treordering_m75,
Tstatprohibit_m165, None RlcPdcpParaGroup
Tpollretrans_m195,
Treordering_m65, 0ms) is set to
Tstatprohibit_m155,
Tpollretrans_m185,
Treordering_m80,
Tstatprohibit_m170, This parameter is
Tpollretrans_m200,
Treordering_m70, RlcMode_AM.
Tstatprohibit_m160,
Tpollretrans_m190,
Treordering_m85,
Tstatprohibit_m175, Treordering_m40(4 valid when RlcMode
Tpollretrans_m205,
Treordering_m75, None RlcPdcpParaGroup
Tstatprohibit_m165,
Tpollretrans_m195,
Treordering_m90,
Tstatprohibit_m180, 0ms) is set to
Tpollretrans_m210,
Treordering_m80,
Tstatprohibit_m170,
Tpollretrans_m200,
Treordering_m95,
Tstatprohibit_m185, This parameter is
RlcMode_AM.
Tpollretrans_m215,
Treordering_m85,
Tstatprohibit_m175,
PdcpSnsize_7bits,
Tpollretrans_m205,
Treordering_m100,
Tstatprohibit_m190, PdcpSnsize_12bits( valid when RlcMode
Tpollretrans_m220,
Treordering_m90, None RlcPdcpParaGroup
Tstatprohibit_m180,
PdcpSnsize_12bits
Tpollretrans_m210,
Treordering_m110,
Tstatprohibit_m195, 12 bits per second) is set to
Tpollretrans_m225,
Treordering_m95,
Tstatprohibit_m185,
Tpollretrans_m215,
Treordering_m120,
Tstatprohibit_m200, RlcMode_UM.
Tpollretrans_m230,
Treordering_m100,
Tstatprohibit_m190,
Tpollretrans_m220,
Treordering_m130,
Tstatprohibit_m205,
Tpollretrans_m235,
Treordering_m110,
Tstatprohibit_m195,
Tpollretrans_m225,
Treordering_m140,
Tstatprohibit_m210,
Tpollretrans_m240,
Treordering_m120,
Tstatprohibit_m200,
Tpollretrans_m230,
Treordering_m150,
Tstatprohibit_m215,
Tpollretrans_m245,
Treordering_m130,
Tstatprohibit_m205,
Tpollretrans_m235,
Treordering_m160,
Tstatprohibit_m220,
Tpollretrans_m250,
Treordering_m140,
Tstatprohibit_m210,
Tpollretrans_m240,
Treordering_m170,
Tstatprohibit_m225,
Tpollretrans_m300,
Treordering_m150,
Tstatprohibit_m215,
Tpollretrans_m245,
Treordering_m180,
Tstatprohibit_m230,
Tpollretrans_m350,
Treordering_m10,
Treordering_m0,
Treordering_m15,
Treordering_m5,
Treordering_m20,
Treordering_m10,
Treordering_m25,
Treordering_m15,
Treordering_m30,
Treordering_m20,
Treordering_m35,
Treordering_m25,
Treordering_m40, This parameter is
Treordering_m30,
Treordering_m45,
RlcSnSize_size5, RlcSnSize_size10(1 valid when RlcMode
Treordering_m35,
Treordering_m50, None RlcPdcpParaGroup
RlcSnSize_size10 0bits) is set to
Treordering_m40,
Treordering_m55, RlcMode_UM.
This parameter is
Treordering_m45,
RlcSnSize_size5,
Treordering_m60, RlcSnSize_size10(1
Treordering_m50, None RlcPdcpParaGroup valid when RlcMode
RlcSnSize_size10
Treordering_m65, 0bits)
Treordering_m55, is setparameter
This to UM. is
Treordering_m70,
Treordering_m60, Treordering_m50(5 valid when RlcMode
Treordering_m75, None RlcPdcpParaGroup
Treordering_m65, 0ms) is set to
Treordering_m80, This parameter is
Treordering_m70, RlcMode_UM.
Treordering_m85, Treordering_m50(5 valid when RlcMode
Treordering_m75,
Treordering_m90, None RlcPdcpParaGroup
0ms) is set to
Treordering_m80,
Treordering_m95, This parameter is
RlcMode_UM.
Treordering_m85,
Treordering_m100, valid when RlcMode
FALSE, TRUE
Treordering_m90, TRUE(TRUE) TRUE(TRUE) RlcPdcpParaGroup
Treordering_m110, is set to
Treordering_m95,
Treordering_m120,
QCI1, QCI2, QCI3, RlcMode_AM.
Treordering_m100,
Treordering_m130,
QCI4, QCI5, QCI6,
MinGbrRate_0_KB, None None StandardQci None
Treordering_m110,
Treordering_m140,
QCI7, QCI8, QCI9
MinGbrRate_1_KB, QCI6: 1000
Treordering_m120,
Treordering_m150,
MinGbrRate_2_KB, This parameter is
QCI7: 900
Treordering_m130,
0.001~1, step:0.001
MinGbrRate_0_KB,
Treordering_m160,
MinGbrRate_4KB, 700 StandardQci valid only for QCIs
QCI8: 800
Treordering_m140,
MinGbrRate_1_KB, QCI6: 6 to 9.
Treordering_m170,
MinGbrRate_8_KB, QCI9: 1000
700 This parameter is
Treordering_m150,
MinGbrRate_2_KB,
Treordering_m180,
MinGbrRate_16_K QCI7: 900
0.001~1, step:0.001
Treordering_m160,
MinGbrRate_4KB, 700 StandardQci valid only for QCIs
Treordering_m190,
B, QCI8: 800
Treordering_m170,
MinGbrRate_8_KB, 6 to 9.
Treordering_m200
MinGbrRate_32_K QCI9: 700 This parameter is
Treordering_m180,
MinGbrRate_16_K MinGbrRate_1_KB( MinGbrRate_1_KB(
B, StandardQci valid only for QCIs
Treordering_m190,
B, 1KB/s) 1KB/s)
MinGbrRate_64_K 6 to 9.
Treordering_m200
MinGbrRate_32_K
B, This parameter is
MinGbrRate_1_KB( MinGbrRate_1_KB(
B,
MinGbrRate_128_K StandardQci valid only for QCIs
1KB/s) 1KB/s)
MinGbrRate_64_K
B, 6 to 9.
B, This parameter is
MinGbrRate_256_K
0~1, step:0.1 10 10 StandardQci valid only for QCIs
MinGbrRate_128_K
B,
B, 6 to 9.
MinGbrRate_512_K
MinGbrRate_256_K
B
0~39 0 None StandardQci None
B,
MinGbrRate_512_K
PBR_0_KBps,
B
0~39
PBR_8_KBps, 0 None StandardQci None
PBR_16_KBps,
This parameter is
PBR_32_KBps, PBR_64_KBps(64K PBR_64_KBps(64K
StandardQci valid only for QCIs
PBR_64_KBps, B/s) B/s)
QCI 6: 9 6 to 9.
PBR_128_KBps, This parameter is
PBR_256_KBps, QCI 7: 10
9~16 11 StandardQci valid only for QCIs
PBR_INFINITY QCI 8: 11
6 to 9.
CLASS_0, QCI 9: 12
CLASS_1(CLASS_ CLASS_1(CLASS_
CLASS_1, AlgoDefaultPara None
1) 1)
CLASS_2
NO_ADAPTIVE,
OL_ADAPTIVE, OL_ADAPTIVE(OL OL_ADAPTIVE(OL MimoAdaptivePara
None
CL_ADAPTIVE, _ADAPTIVE) _ADAPTIVE) Cfg This parameter is
OC_ADAPTIVE valid only when
TM2, TM3, TM4, MimoAdaptivePara
TM3(TM3) TM3(TM3) MimoAdaptiveSwitc
TM6 Cfg
GAP_PATTERN_T h is set to
YPE_1, GAP_PATTERN_T GAP_PATTERN_T NO_ADAPTIVE.
HoMeasComm None
GAP_PATTERN_T
FC0, FC1, FC2, YPE_1 YPE_1
YPE_2
FC3, FC4, FC5,
FC6, FC7, FC8, FC6 FC6 HoMeasComm None
FC0,
FC9, FC1,
FC11,FC2,
FC13,
FC3,
FC15,FC4, FC5,
FC17, FC19
FC6, FC7, FC8, FC6 FC6 HoMeasComm None
FC0,
FC9, FC1,
FC11,FC2,
FC13,
FC3,
FC15,FC4, FC5,
FC17, FC19
FC6, FC7, FC8, FC6 FC6 HoMeasComm None
FC9, FC11, FC13,
FC15, FC17, FC19
NOT_CFG, CFG NOT_CFG NOT_CFG HoMeasComm None
-141~-44 -44 -44 HoMeasComm None

NOT_CFG, CFG NOT_CFG NOT_CFG HoMeasComm None


T_CRMAX_30S,
T_CRMAXHYST_3
T_CRMAX_60S,
0S, T_CRMAX_60S(60 T_CRMAX_60S(60
T_CRMAX_120S,
T_CRMAXHYST_6 HoMeasComm None
s) s)
T_CRMAX_180S,
0S, In the
T_CRMAX_240S
T_CRMAXHYST_1 T_CRMAXHYST_6 T_CRMAXHYST_6 HoMeasComm MO,
HoMeasComm None
20S, 0S(60s) 0S(60s) if
T_CRMAXHYST_1 In the
SpeedDepParaInd
80S,
1~16 4 4 HoMeasComm HoMeasComm
is set to CFG, MO,
T_CRMAXHYST_2 ifNcrHighConnMode
40S
TTT_SF_MEDIUM_ SpeedDepParaInd
must be larger than
1~16
0DOT25, 8 8 HoMeasComm is set to CFG,
NcrMediumConnMo
TTT_SF_MEDIUM_ NcrHighConnMode
de.
TTT_SF_HIGH_0D
0DOT50, TTT_SF_MEDIUM_ TTT_SF_MEDIUM_ must be larger than
OT25, HoMeasComm None
NcrMediumConnMo
TTT_SF_MEDIUM_ LDOT0(1) LDOT0(1)
TTT_SF_HIGH_0D
0DOT75, de.
OT50,
TTT_SF_MEDIUM_ TTT_SF_HIGH_0D TTT_SF_HIGH_0D
HoMeasComm None
TTT_SF_HIGH_0D
FC0,
LDOT0FC1, FC2, OT75(0.75) OT75(0.75)
OT75,FC4, FC5,
FC3,
TTT_SF_HIGH_LD
FC6, FC7, FC8, FC6 FC6 HoMeasComm None
FC0,
FC9, FC1,
OT0 FC11,FC2,
FC13,
FC3,
FC15,FC4, FC5,
FC17, FC19
FC6, FC7, FC8, FC6 FC6 HoMeasComm None
FC9, FC11, FC13,
FC15, FC17, FC19
1~8 4 4 InterRatHoComm None

r1, r2, r4, r8, r16,


120ms, Infinity(Infinity) infinity(Infinity) InterRatHoComm None
r32, r64,240ms,
Infinity
480ms, 640ms,
1024ms, 2048ms,
480ms 480ms InterRatHoComm None
5120ms, 10240ms,
1min, 6min, 12min,
UTRAN_RSCP,
30min,
120ms, 60min
UTRAN_ECN0,
240ms, UTRAN_RSCP UTRAN_RSCP InterRatHoComm None
UTRAN_BOTH
480ms, 640ms,
1024ms, 2048ms,
480ms 480ms InterRatHoComm None
5120ms, 10240ms,
1min, 6min, 12min,
30min,
120ms,60min
PILOT_STRENGTH
240ms, PILOT_STRENGTH PILOT_STRENGTH InterRatHoComm None
480ms, 640ms,
1024ms, 2048ms,
480ms 480ms InterRatHoComm None
5120ms, 10240ms,
1min, 6min, 12min,
30min,
120ms,60min
PILOT_STRENGTH
240ms, PILOT_STRENGTH PILOT_STRENGTH InterRatHoComm None
480ms, 640ms,
1024ms, 2048ms,
480ms 480ms InterRatHoComm None
5120ms, 10240ms,
1min, 6min, 12min,
RSRP,
30min, RSRQ,
60min BOTH BOTH InterRatHoComm None
BOTH

1~8 4 4 IntraRatHoComm None

r1, r2, r4, r8, r16,


Infinity(Infinity) infinity(Infinity) IntraRatHoComm None
r32, r64, Infinity

RSRP, RSRQ RSRP RSRP IntraRatHoComm None


SAME_AS_TRIG_ SAME_AS_TRIG_
SAME_AS_TRIG_
120ms, 240ms, QUAN(Same as QUAN(Same as IntraRatHoComm None
QUAN, BOTH
480ms, 640ms, Trig Quan) Trig Quan)
1024ms, 2048ms,
240ms 240ms IntraRatHoComm None
5120ms, 10240ms,
1min, 6min, 12min,
SAME_AS_TRIG_
30min, 60min
120ms, 240ms, BOTH BOTH IntraRatHoComm None
QUAN, BOTH
480ms, 640ms,
1024ms, 2048ms,
240ms 240ms IntraRatHoComm None
5120ms, 10240ms,
1min, 6min, 12min,
RSRP,
30min, RSRQ,
60min BOTH BOTH IntraRatHoComm None
BOTH
RSRP, RSRQ,
RSRP RSRP IntraRatHoComm None
BOTH
RSRP, RSRQ,
RSRP RSRP IntraRatHoComm None
BOTH
0ms, 40ms, 64ms,
0~11 100ms,
80ms, None None CSFallBackHo None
128ms, 160ms,
0ms, 40ms,
256ms, 64ms,
320ms,
80ms, 100ms, 40ms 40ms CSFallBackHo None
480ms, 512ms,
128ms,
640ms, 160ms,
1024ms,
0ms, 40ms,
256ms, 64ms,
320ms,
1280ms,
80ms, 2560ms,
100ms, 40ms 40ms CSFallBackHo None
480ms,
5120ms 512ms,
128ms,
640ms, 160ms,
1024ms,
256ms,
1280ms,320ms,
2560ms, 40ms 40ms CSFallBackHo None
480ms,
5120ms512ms,
640ms, 1024ms,
1280ms,
-120~-25 2560ms, -106 -106 CSFallBackHo None
5120ms

-24~0, step:0.5 -13 -13 CSFallBackHo None


If this parameter is
set to CFG, the
following
-110~-48 -103 -103 CSFallBackHo None
parameters must be
set:
-31.5~0, step:0.5 -34 -34 CSFallBackHo AcBarringForEmerg
None
ency,
AcBarringForMoDat
0~11 None None CellAcBar None
aCfgInd, and
AcBarringForMoSig
NOT_CFG(Not NOT_CFG(Not CfgInd.
NOT_CFG, CFG CellAcBar AcBarringForEmerg
configure) configure) If this parameter is
ency
set toisNOT_CFG,
optional,
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( depending
the following on the
CellAcBar AcBarringForMoDat
BOOLEAN_TRUE
ACCESS_BARRIN False) False) setting
parametersof do not
G_TIME_S4, aCfgInd is optional,
AcBarringInfoCfgIn
NOT_CFG(Not NOT_CFG(Not need to
depending be set:
on the
ACCESS_BARRIN
NOT_CFG, CFG CellAcBar d.
AcBarringForEmerg
AcBarringFactorFor
P00, P05, P10,
G_TIME_S8, configure) configure) setting of
ency,
Call is optional,
AcBarringInfoCfgIn
P15, P20, P25,
ACCESS_BARRIN AcBarringForMoDat
depending
d. on the
P30, P40, P50,
G_TIME_S16, P95(95%) P95(95%) CellAcBar AcBarTimeForCall
aCfgInd,
setting ofand
P60, P70, P75,
ACCESS_BARRIN is optional,
AcBarringForMoSig
AcBarringForMoDat
P80, P85, P90, P95
G_TIME_S32, ACCESS_BARRIN ACCESS_BARRIN depending
CellAcBar aCfgInd. on the
CfgInd.
ACCESS_BARRIN G_TIME_S4(4s) G_TIME_S4(4s) setting of
AC11BarforCall is
G_TIME_S64, AcBarringForMoDat
optional, depending
BOOLEAN_FALSE,
ACCESS_BARRIN BOOLEAN_FALSE( BOOLEAN_FALSE( aCfgInd.
CellAcBar on the setting of
BOOLEAN_TRUE
G_TIME_S128, False) False) AC12BarforCall is
AcBarringForMoDat
ACCESS_BARRIN optional,
aCfgInd. depending
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
G_TIME_S256, CellAcBar on the setting of
BOOLEAN_TRUE False) False)
ACCESS_BARRIN AcBarringForMoDat
G_TIME_S512 aCfgInd.
AC13BarforCall is
optional, depending
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
CellAcBar on the setting of
BOOLEAN_TRUE False) False) AC14BarforCall is
AcBarringForMoDat
optional,
aCfgInd. depending
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
CellAcBar on the setting of
BOOLEAN_TRUE False) False) AC15BarforCall is
AcBarringForMoDat
optional,
aCfgInd. depending
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
CellAcBar on the setting of
AcBarringForMoDat
BOOLEAN_TRUE
ACCESS_BARRIN False) False)
AcBarringForMoDat
aCfgInd is optional,
G_TIME_S4,
NOT_CFG(Not NOT_CFG(Not aCfgInd. on the
depending
ACCESS_BARRIN
NOT_CFG, CFG CellAcBar AcBarringFactorFor
P00, P05, P10,
G_TIME_S8, configure) configure) setting of
Sig is optional,
AcBarringInfoCfgIn
P15, P20, P25,
ACCESS_BARRIN depending
d. on the
P30, P40, P50,
G_TIME_S16, P95(95%) P95(95%) CellAcBar
setting of
AcBarTimeForSig is
P60, P70, P75,
ACCESS_BARRIN AcBarringForMoSig
optional, depending
P80, P85, P90, P95
G_TIME_S32, ACCESS_BARRIN ACCESS_BARRIN
CellAcBar CfgInd.
on the setting of
ACCESS_BARRIN G_TIME_S4(4s) G_TIME_S4(4s) AC11BarForSig is
AcBarringForMoSig
G_TIME_S64, optional,
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CfgInd. depending
ACCESS_BARRIN CellAcBar on the setting of
BOOLEAN_TRUE
G_TIME_S128, False) False) AC12BarForSig is
AcBarringForMoSig
ACCESS_BARRIN optional,
CfgInd. depending
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
G_TIME_S256, CellAcBar on the setting of
BOOLEAN_TRUE False) False) AC13BarForSig is
ACCESS_BARRIN AcBarringForMoSig
optional,
CfgInd. depending
G_TIME_S512
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
CellAcBar on the setting of
BOOLEAN_TRUE False) False) AC14BarForSig is
AcBarringForMoSig
optional,
CfgInd. depending
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
CellAcBar on the setting of
BOOLEAN_TRUE False) False) AC15BarForSig is
AcBarringForMoSig
optional,
CfgInd. depending
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
CellAcBar on the setting of
BOOLEAN_TRUE False) False)
AcBarringForMoSig
CfgInd.
0~11 None None CellAccess None
CELL_BARRED,
CELL_NOT_BARR CELL_NOT_BARR
CELL_NOT_BARR CellAccess None
ED(Not Barred) ED(Not Barred)
ED
CELL_RESERVED, CELL_NOT_RESE CELL_NOT_RESE
CELL_NOT_RESE RVED(Not RVED(Not CellAccess None
RVED Reserved) Reserved)
ALLOWED,
ALLOWED ALLOWED CellAccess None
NOT_ALLOWED
NORMAL_MODE, NORMAL_MODE(N NORMAL_MODE(N
CellAccess None
RR_MODE ormal mode) ormal mode)

1~720 1 1 CellAccess None

0~11 None None CellOp None

0~65535 None None CellOp None


CELL_RESERVED
CELL_NOT_RESE CELL_NOT_RESE
_FOR_OP,
RVED_FOR_OP(N RVED_FOR_OP(N CellOp None
CELL_NOT_RESE
ot Reserved) ot Reserved) The sum of
RVED_FOR_OP
OpUlRbUsedRatio
1~100 25 25 CellOp
in all CellOp MOs
The
cannotsum of
exceed 100.
OpUlRbUsedRatio
1~100 25 25 CellOp
in all CellOp MOs
cannot exceed 100.
0~11 None None CellResel None
DB0_Q_HYST, the following
DB1_Q_HYST, parameters must be
DB2_Q_HYST, set:
DB3_Q_HYST, TEvaluation,
This parameter is
DB4_Q_HYST, THystNormal,
optional. Whether
DB5_Q_HYST, NCellChangeMediu
to configure this
DB6_Q_HYST, This
m,
parameterparameter is is
DB8_Q_HYST, optional.
NCellChangeHigh,
1. This
determined Whether
parameter
by the is
DB4_Q_HYST(4dB) DB4_Q_HYST(4dB) CellResel None
DB10_Q_HYST,
S30_T_EVALULATI to
parameter this
configure
QHystSfMedium,
optional, depending
DB12_Q_HYST,
ON, parameter
QHystSfHigh.
on the setting
SpeedDepReselCfg is of
DB14_Q_HYST,
NOT_CFG, CFG CFG(Configure) CFG(Configure) CellResel 1.
If This
determined parameter
SpeedDepReselCfg by the is
S60_T_EVALULATI Ind.
DB16_Q_HYST,
S30_T_HYST_NOR optional,
parameter
SpeedDepReselCfg
Ind. depending
ON, When
DB18_Q_HYST,
MAL, on the setting
SpeedDepReselCfg
Ind
If is set to of
S120_T_EVALULA S60_T_EVALULATI S60_T_EVALULATI SpeedDepReselCfg
DB20_Q_HYST,
S60_T_HYST_NOR CellResel SpeedDepReselCfg
Ind.
NOT_CFG,
TION, ON(60s) ON(60s) Ind is set to the
SpeedDepReselCfg CFG,
DB22_Q_HYST,
MAL, Ind.
When
following
Ind is set to CFG,
S180_T_EVALULA TEvaluation needs
DB24_Q_HYST
S120_T_HYST_NO S30_T_HYST_NOR S30_T_HYST_NOR If
SpeedDepReselCfg
parameters
TION, CellResel This be parameternot
NCellChangeMediu
to do
configured.
SpeedDepReselCfg is
RMAL,
S240_T_EVALULA MAL(30s) MAL(30s) Ind
need
m
When is to
must setbetoset.
CFG,
set:
optional,
Ind is set depending
to CFG,
S180_T_HYST_NO
TION THystNormal
TEvaluation,
If
SpeedDepReselCfg needs
on the setting of
NCellChangeHigh
RMAL,
1~16 4 4 CellResel to be configured.
THystNormal,
SpeedDepReselCfg
Ind isparameter
set to
SpeedDepReselCfg
This
must is
S240_T_HYST_NO When is besetset.
NCellChangeMediu
Ind
NOT_CFG,
Ind. to
RMAL
DB_6_Q_HYST_SF optional,
If
SpeedDepReselCfg
m, depending
NOT_CFG,
TEvaluation
If does
1~16
_MEDIUM, 8 8 CellResel on the setting
SpeedDepReselCfg
Ind is set
NCellChangeHigh, to beof
NCellChangeMediu
not
This need to
DB_4_Q_HYST_SF isparameter
NOT_CFG, set to needisto
SpeedDepReselCfg
Ind
QHystSfMedium,
m does
DB_6_Q_HYST_SF Ind is setnot
configured.
optional.
Ind.
NOT_CFG, to CFG,
Whether
_MEDIUM, DB0_Q_HYST_SF_ DB0_Q_HYST_SF_ THystNormal
QHystSfHigh.
be
If set. does
_HIGH, CellResel QHystSfMedium
to
If configure
NCellChangeHigh this
DB_2_Q_HYST_SF MEDIUM(0dB) MEDIUM(0dB) not
2. Inneed
the to be
CellResel
SNonIntraSearchCf
DB_4_Q_HYST_SF must
parameter be
notset.
SpeedDepReselCfg
does is to be
need
_MEDIUM, configured.
MO,
gInd issetsettotobyCFG,
_HIGH, DB0_Q_HYST_SF_ DB0_Q_HYST_SF_ If
determined
Ind
set. is CFG,the
DB0_Q_HYST_SF_ CellResel NCellChangeHigh
SNonIntraSearch
DB_2_Q_HYST_SF HIGH(0dB) HIGH(0dB) SpeedDepReselCfg
parameter
QHystSfHigh
2. In the must
CellResel
MEDIUM must
_HIGH, must
Ind is be
besetlarger
set.
SNonIntraSearchCf
be
MO, set. to than
NCellChangeMediu
If
NOT_CFG,
gInd.
DB0_Q_HYST_SF_
NOT_CFG, CFG CFG(Configure) CFG(Configure) CellResel If
NCellChangeHigh
m.
SNonIntraSearchCf
QHystSfMedium
When
HIGH SpeedDepReselCfg
must be larger than
gInd
does isisnotsetneed
SNonIntraSearchCf
Ind set toto to be
NCellChangeMediu
0~62, step:2 5 5 CellResel NOT_CFG,
set.
gInd
m. is set to CFG,
NOT_CFG,
SNonIntraSearch
SNonIntraSearch
QHystSfHigh does
does
needs
not need not need
to be to
to be set. be
0~62, step:2 0 0 CellResel None
set.
configured.
When
0~7 7 7 CellResel SNonIntraSearchCf
None
gInd is set to
NOT_CFG,
-140~-44, step:2 -64 -64 CellResel If
NonePMaxCfgInd is
SNonIntraSearch
This
set toparameter
CFG, PMax is
does
optional, not need
dependingto be
must be set.
configured.
NOT_CFG(Not NOT_CFG(Not This
on theparameter
setting of is
NOT_CFG, CFG CellResel If PMaxCfgInd is
configure) configure) optional.
PMaxCfgInd.
If Whether
set to NOT_CFG,
to
If set this
PMaxCfgInd
does notis
SIntraSearchCfgInd
PMax
-30~33 23 23 CellResel parameter
set
is to CFG,
set to be CFG,isPMax
need set.
determined
must be set.bymust
SIntraSearch the
parameter
If PMaxCfgInd
be set. is
NOT_CFG, CFG CFG(Configure) CFG(Configure) CellResel If
This
set toparameter
SIntraSearchCfgInd
If NOT_CFG, is
MeasBandWidthCfg
optional,
.PMax depending
does
SIntraSearchCfgInd not
Ind
on is set
the to CFG,
setting
0~62, step:2 29 29 CellResel
When
need
is set to be set.of
NOT_CFG,
MeasBandWidth
MeasBandWidthCfg
SIntraSearchCfgInd
If
SIntraSearch
must
Ind.
is set be set. does
to CFG,
SpeedStateSfCfgIn
not need to be set.
NOT_CFG(Not NOT_CFG(Not If
If
SIntraSearch needs
NOT_CFG, CFG CellResel d is set to CFG, the
configure) configure) MeasBandWidthCfg
MeasBandWidthCfg
to be set.
following
MBW6, MBW15, Ind
Ind
When is set
is set to
to CFG,
DL bandwidth of the parameters must be
MBW25, MBW50, MBW6(1.4M) CellResel NOT_CFG,
MeasBandWidth
This parameter
SIntraSearchCfgInd is
serving cell set:
MBW75, MBW100 MeasBandWidth
must
optional,
is set be
to set.
depending
NOT_CFG,
TReselEutranSfMe
does
If
on not
theand
SIntraSearch needdoes
setting oftothe
be
0~7 1 1 CellResel dium
None
This parameter is
set.
MeasBandWidthCfg
SpeedStateSfCfgIn
not need to be set.
TReselEutranSfHig
optional,
Ind
d
h. is set depending
parameter. to
T_RESEL_SF_0DO on the setting of the
NOT_CFG, CFG CFG(Configure) CFG(Configure) CellResel NOT_CFG,
If
If
T25, SpeedStateSfCfgIn
MeasBandWidth
SpeedStateSfCfgIn
SpeedStateSfCfgIn
T_RESEL_SF_0DO d parameter.
T_RESEL_SF_0DO does
d
d is
is set
setnotto
toneed
CFG,to be
T5, T_RESEL_SF_1DO T_RESEL_SF_1DO If
T25, CellResel set.
TReselEutranSfMe
NOT_CFG, the
T_RESEL_SF_0DO T0(1.0) T0(1.0) SpeedStateSfCfgIn
T_RESEL_SF_0DO dium
followingmust be set.
T75, d is set to CFG,
T5, T_RESEL_SF_0DO T_RESEL_SF_0DO If
parameters do not
T_RESEL_SF_1DO CellResel TReselEutranSfHig
T_RESEL_SF_0DO T75(0.75) T75(0.75) SpeedStateSfCfgIn
need to be set:
T0 h must
T75, d is set be to set.
TReselEutranSfMe
If
NOT_CFG,
T_RESEL_SF_1DO dium and
SpeedStateSfCfgIn
TReselEutranSfMe
T0 TReselEutranSfHig
d is set
dium doesto not need
h.
NOT_CFG,
to be set.
TReselEutranSfHig
h does not need to
be set.
BitString00,
BitString01,
BitString01(01) BitString01(01) CellResel None
BitString10,
BitString11
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE(
CellResel None
BOOLEAN_TRUE False) False)
1.SysTimeCfgInd
If This parameter is is
CellReselCdma200 This
optional,
set toparameter
CFG, depending is
0~11 None None None
optional, depending
0 on the setting
CdmaEutraSyn of
on
must be set. of
the setting
HrpdParamCfgInd.
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 SysTimeCfgInd.
If HrpdParamCfgInd
NOT_CFG, CFG SysTimeCfgInd
This
If parameter is is
HrpdParamCfgInd
configure) configure) 0 If SysTimeCfgInd
SearchWndSizeCfg
is set is
set
is set to to
optional, to CFG,
NOT_CFG,
depending
CFG, the
set
Ind to
is CFG,
set
HrpdCellReselectP
CdmaEutraSyn
on the to
setting CFG,of
BOOLEAN_FALSE, BOOLEAN_TRUE( BOOLEAN_TRUE( CellReselCdma200 following
CdmaEutraSyn
SearchWndSize
aramCfgInd
does not need
SearchWndSizeCfg mustto be
BOOLEAN_TRUE True) True) 0 parameters
1. This must be
must
must
be
set.
Ind.
Ifset.beparameter
be set.
set. is
set:
optional, depending
HrpdPreRegistAllow
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 If HrpdParamCfgInd
If SysTimeCfgInd is
NOT_CFG, CFG HrpdPreRegistAllow
on
ed the
is setsetting
to of
configure) configure) 0 set Ifto toNOT_CFG,
SearchWndSizeCfg
is
1. set
SearchWndSizeCfgNOT_CFG,
ed,
HrpdParamCfgInd.
BOOLEAN_TRUE,
CdmaEutraSyn
Ind is set
set to
HrpdCellReselectP
Cdma1XrttCsfbReg
Ind is to CFG,
CellReselCdma200 HrpdSecondPreRe
If HrpdParamCfgInd
HrpdPreRegistZone
0~15 1 1 does
NOT_CFG,
aramCfgInd
CfgInd not
SearchWndSize is need
set totoand
does be
0 gistZoneId0Ind,
is
Id set
must to beCFG, set.
set.
SearchWndSize
not
CFG,
must need to
theset.
be be set.
following
HrpdCellReselectP
HprdSecondPreRe
If
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 does
2
If IfThis
parameters
aramCfgInd.
This
1. not need
parameter must
parameter tois be
be
is
NOT_CFG, CFG gistZoneId0Ind
HrpdPreRegistAllow
set.
configure) configure) 0 HrpdCellReselectP
SearchWndSizeCfg
set:
If HrpdParamCfgInd
optional, depending
must
ed be set.
is set to is set
aramCfgInd
Ind
Cdma1XrttCsfbReg
is
on set is to
the set to of
NOT_CFG,
setting
If HrpdParamCfgInd
BOOLEAN_FALSE,
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 to CFG,
NOT_CFG,
Sid,
the the
following
HrpdPreRegistAllow
HrpdSecondPreRe
NOT_CFG, CFG is set to NOT_CFG,
HrpdPreRegistZone
configure) configure) 0 following
SearchWndSize
Cdma1XrttCsfbReg
parameters
ed.
gistZoneId0Ind. do notto
HprdSecondPreRe
Id does not need
parameters
does
Nid,
1.
need
If This not
to needmust
parameter
be set: to be is
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 gistZoneId0Ind
be
1. set. parameter is
This
set:
set.
Cdma1XrttCsfbReg
optional, depending
HrpdPreRegistAllow
HrpdSecondPreRe
BOOLEAN_TRUE False) False) 0 does
2. This
optional, not need to be
parameter
depending is
TreselectionHrpd
MultiSidInd,
on
ed,
ed the
is setsetting
gistZoneId0Ind to ofis
set.
optional,
on depending
the setting of
CellReselCdma200 and
Cdma1XrttCsfbReg
HprdSecondPreRe
HrpdSecondPreRe
BOOLEAN_TRUE,
set to CFG,
0~255 1 1 2.
on Ifthe setting of
HrpdCellReselectP
0 SpeedStateSfCfgIn
MultiNidInd,
gistZoneId0Ind.
gistZoneId0Ind,
HrpdPreRegistZone
HrpdSecondPreRe and
HrpdParamCfgInd.
aramCfgInd.
d.
Cdma1XrttCsfbReg
If
HrpdCellReselectP
Id must
gistZoneId1Ind
gistZoneId0Ind
This be set.
parameter is
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 If
If HrpdParamCfgInd
NOT_CFG, CFG HomeRegInd,
HprdSecondPreRe
aramCfgInd.
If
must
set to
optional, be
CFG,set. the
depending
configure) configure) 0 is set to CFG,
HrpdCellReselectP
Cdma1XrttCsfbReg
gistZoneId0Ind
HrpdPreRegistAllow
If
following
on the setting is
HrpdPreRegistAllow
aramCfgInd
ForeignSidRegInd,
set
ed toset
is CFG, to is of
set
CellReselCdma200 HrpdSecondPreRe
parameters
HprdSecondPreRe
edCFG,
This must must
be set.the
parameter is be
0~255 2 2 to NOT_CFG,
Cdma1XrttCsfbReg
HprdSecondPreRe
BOOLEAN_FALSE,
0 gistZoneId0Ind
set:
gistZoneId1Ind.
If HrpdParamCfgInd
optional, depending is
SpeedStateSfCfgIn
following
ForeignNidRegInd,
gistZoneId0
HrpdPreRegistZone must
set
is
on set to to
the NOT_CFG,
HrpSecondPreRegi
If NOT_CFG,
setting
NOT_CFG(Not NOT_CFG(Not CellReselCdma200
d
Id must
parameters
set.
does be
Cdma1XrttCsfbReg
be
HrpdSecondPreRe not doofnotto
set.
need
NOT_CFG, CFG stZoneId0
HprdSecondPreRe
HrpdPreRegistAllow
HrpdCellReselectP
If and
configure) configure) 0 need set.to be set:
ParamRegInd,
If
be
gistZoneId1Ind
HrpdSecondPreRe
gistZoneId1Ind
ed does
aramCfgInd.
HrpdCellReselectPnot need is to
TreselectionHrpd
Cdma1XrttCsfbReg
HprdSecondPreRe
does not need to be
gistZoneId1Ind.
set
be
If to
set.
aramCfgInd CFG, is set
CellReselCdma200 and
PowerUpRegInd,
gistZoneId0Ind
0~255 3 3 set.
If parameter is
HprdSecondPreRe
This
HrpdCellReselectP
to NOT_CFG,
SpeedStateSfCfgIn is
0 Cdma1XrttCsfbReg
set
2. If to NOT_CFG,
HrpdSecondPreRe
gistZoneId1
optional,
aramCfgInd
SpeedStateSfCfgIn must
depending
is set
d.
RegPeriod,
HprdSecondPreRe
HrpdSecondPreRe
CellReselCdma200 gistZoneId0Ind
be
on
to
This
d set.
the
CFG,
does setting
parameter
not need ofis
isto
0~7 1 1 Cdma1XrttCsfbReg
gistZoneId0
gistZoneId1Ind
If
setCdma1XrttCfgInd
to NOT_CFG, does is
0 SpeedStateSfCfgIn
TreselectionHrpd
optional,
be set. depending
RegZone,
not
set
is
the set need
to CFG,
to to bethe
CFG,
following
HprdSecondPreRe set.
d.
must
on
2 Ifthe be set. of
setting
T_RESEL_SF_0DO NOT_CFG(Not NOT_CFG(Not CellReselCdma200 Cdma1XrttCsfbReg
HrpdSecondPreRe
following
parameters do not
NOT_CFG, CFG gistZoneId1Ind
If
SpeedStateSfCfgIn is
T25, configure) configure) 0 TotalZone,
gistZoneId1
parameters
need to be must be
must
set:
set to NOT_CFG,
SpeedStateSfCfgIn
HrpdCellReselectP
d.
d is set to CFG, the
T_RESEL_SF_0DO Cdma1XrttCsfbReg
be
T_RESEL_SF_0DO If isset.
set:
HrpdSecondPreRe
HprdSecondPreRe
d
followingset to CFG,
aramCfgInd is set
T5, T_RESEL_SF_0DO T_RESEL_SF_0DO CellReselCdma200 ZoneTimer.
If
Cdma1XrttCsfbReg
gistZoneId0 and
T25, gistZoneId1
TReselCdmaHprdSf
to NOT_CFG,
SpeedStateSfCfgIn
parameters does be
must
T_RESEL_SF_0DO T75(0.75) T75(0.75) 0 If
HrpdSecondPreRe
CfgInd,
T_RESEL_SF_0DO not
High need
must
TreselectionHrpd
d is
set: set to tobebe
CFG, set.
set.
T75, Cdma1XrttCsfbReg
gistZoneId1Ind
Cdma1XrttLongCod
gistZoneId1Ind. is
If
does not
T5,
T_RESEL_SF_1DO T_RESEL_SF_1DO T_RESEL_SF_1DO CellReselCdma200 This is need
parameter
TReselCdmaHrpdSf
CfgInd
set to set toand
NOT_CFG,
eStateCfgInd,
tois be
T_RESEL_SF_0DO T0(1.0) T0(1.0) 0 SpeedStateSfCfgIn
set.
Medium
optional, and must
dependingbe
T0 NOT_CFG,
HrpdSecondPreRe
Cdma1XrttCellRese the
T75, d isthe
set.
on setsetting
to
TReselCdmaHrpdSf of
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 following
gistZoneId1
lCfgInd.
This parameter does is
T_RESEL_SF_1DO
NOT_CFG, CFG NOT_CFG,
If
Cdma1XrttCsfbReg
High.
configure) configure) 0 parameters
not
If need
Cdma1XrttCfgInd
optional, to do set.
be
depending not
T0 TReselCdmaHprdSf
SpeedStateSfCfgIn
CfgInd.
If
need
is
on setthe to be
tosetting set:
NOT_CFG,
High
d
If is does
set to
SpeedStateSfCfgIn not ofneed
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 Cdma1XrttCsfbReg
the following
Cdma1XrttCsfbReg
NOT_CFG, CFG to be
NOT_CFG, set.
Cdma1XrttCsfbReg
d is set to
configure) configure) 0 Sid,
parameters
CfgInd.
CfgInd
NOT_CFG, is setdo
TReselCdmaHrpdSf
Cdma1XrttCsfbReg to not
the
CellReselCdma200 need
If
Medium
CFG, to be set:
does not
0~32767 0 0 following
Nid,
0 Cdma1XrttCsfbReg
need to
Cdma1XrttCsfbReg
parameters be set.
do not
Cdma1XrttCsfbReg
CfgInd,
CfgInd isbeset to
Sid
need must
to
MultiSidInd, be set.
set:
CellReselCdma200 Cdma1XrttLongCod
CFG,
If
0~65535 0 0 TReselCdmaHrpdSf
Cdma1XrttCsfbReg
0 eStateCfgInd,
Cdma1XrttCsfbReg
Cdma1XrttCsfbReg and
Medium and
MultiNidInd,
Cdma1XrttCellRese
Nid
CfgInd must be
is set toset.
TReselCdmaHrpdSf
Cdma1XrttCsfbReg
lCfgInd.
If
NOT_CFG,
High.
HomeRegInd,
Cdma1XrttCsfbReg
Cdma1XrttCsfbReg
Cdma1XrttCsfbReg
CfgInd is not
set to
Sid does
ForeignSidRegInd, need
NOT_CFG,
to be set.
Cdma1XrttCsfbReg
Cdma1XrttCsfbReg
ForeignNidRegInd,
Nid does not need
Cdma1XrttCsfbReg
optional, depending
Cdma1XrttCsfbReg
on the setting of
MultiNidInd
Cdma1XrttCsfbReg is
optional,
CfgInd. depending
Cdma1XrttCsfbReg
on the setting of
If
HomeRegInd is
Cdma1XrttCsfbReg
Cdma1XrttCsfbReg
optional,
Cdma1XrttCsfbReg
CfgInd. depending
CfgInd
on is set toof
the setting
FrgnSidRegInd
If is
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 CFG,
Cdma1XrttCsfbReg
optional,
Cdma1XrttCsfbReg depending
BOOLEAN_TRUE False) False) 0 Cdma1XrttCsfbReg
Cdma1XrttCsfbReg
CfgInd.
on
CfgInd the setting
is setmust toof be
MultiSidInd
FrgnNidRegInd
If is
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Cdma1XrttCsfbReg
CFG,
set.
optional,
Cdma1XrttCsfbReg depending
BOOLEAN_TRUE False) False) 0 CfgInd.
Cdma1XrttCsfbReg
If
on
CfgInd the setting
is setmust
Cdma1XrttCsfbReg toof be
If
MultiNidInd
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Cdma1XrttCsfbReg
Cdma1XrttCsfbReg
CFG,
ParamRegInd is
Cdma1XrttCsfbReg
set.
BOOLEAN_TRUE False) False) 0 CfgInd
CfgInd. is depending
Cdma1XrttCsfbReg
optional, set to
CfgInd is set to
Cdma1XrttCsfbReg
If
NOT_CFG,
If
HomeRegInd
on the setting must of is
CFG,
PowerUpRegInd
Cdma1XrttCsfbReg
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Cdma1XrttCsfbReg
Cdma1XrttCsfbReg
be set.
Cdma1XrttCsfbReg
optional,
CfgInd
MultiSidInd is depending
set to
BOOLEAN_TRUE False) False) 0 CfgInd
If
CfgInd.
FrgnSidRegInd
on the is setdoes
setting to
NOT_CFG,
not
CFG,
This need
parameter
Cdma1XrttCsfbReg
If to beofset. is
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 must be set.
Cdma1XrttCsfbReg
Cdma1XrttCsfbReg
optional,
CfgInd depending
is setdoes
Cdma1XrttCsfbReg
If
CfgInd. to
BOOLEAN_TRUE False) False) 0 MultiNidInd
FrgnNidRegInd
on
NOT_CFG,
CfgInd the setting
is to
Cdma1XrttCsfbReg
If setbe toofset.
not
This need
parameter is
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 must
CFG,
CfgInd be
Cdma1XrttCsfbReg set.
is depending
Cdma1XrttCsfbReg set to
optional,
If
CfgInd.
HomeRegInd
BOOLEAN_TRUE False) False) 0 is set todoes
Cdma1XrttCsfbReg
NOT_CFG,
CfgInd
on
notthe
ParamRegInd
setting
Cdma1XrttCsfbReg
If need
Cdma1XrttCsfbReg
CFG,
This parameterto beof set.
must
is
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( CellReselCdma200 Cdma1XrttCsfbReg
1.
CfgIndIf is
Cdma1XrttCsfbReg set to
be set. depending
FrgnSidRegInd
Cdma1XrttCsfbReg
optional,
BOOLEAN_TRUE False) False) 0 CfgInd.
Cdma1XrttLongCod
NOT_CFG,
CfgInd is need
set toofto be
If
does thenot
PowerUpRegInd
on
1. setting
If
eStateCfgInd
CFG,
This parameter is isset
CellReselCdma200 Cdma1XrttCsfbReg
set.
must be set.
Cdma1XrttCsfbReg
Cdma1XrttCellRese
0~127 0 0 Cdma1XrttCsfbReg
to CFG,
FrgnNidRegInd
Cdma1XrttCsfbReg
optional,
0 CfgInd
If
CfgInd.
lCfgInd isisdepending
set to
optional,
CfgInd
on thenot
RegPeriod is need
Cdma1XrttLongCod
does set
setting tooftobe
must be
NOT_CFG,
Cdma1XrttCsfbReg
If
depending
CFG,
eState
1.
set. mustonbethe
Cdma1XrttCsfbReg set.
CellReselCdma200 CfgInd is set to
Cdma1XrttCsfbReg
setting of
0~4095 0 0 Cdma1XrttCsfbReg
If
Cdma1XrttSpeedSt
If
CfgInd.
0 ParamRegInd
NOT_CFG,
CfgInd is set
Cdma1XrttCfgInd. todoes
RegZone
Cdma1XrttLongCod
ateCfgInd
Cdma1XrttCsfbReg
If must
is be
not need
Cdma1XrttCsfbReg
CFG,
If Cdma1XrttCfgIndto be set.
CellReselCdma200 set.
eStateCfgInd
This
optional,
CfgInd parameter
is set to is
Cdma1XrttCsfbReg dependingis set
0~7 0 0 PowerUpRegInd
Cdma1XrttCsfbReg
is
If
to set tosetting
NOT_CFG, CFG,
0 optional,
on
NOT_CFG,
CfgInd the depending
is need
set of
totobebe
does
TotalZone not
Cdma1XrttCellRese
Cdma1XrttCsfbReg
Cdma1XrttLongCod must
on the setting of
Cdma1XrttCellRese
Cdma1XrttCsfbReg
CFG,
set.
CellReselCdma200 lCfgInd
CfgInd
eState ismust
does
Cdma1XrttLongCod
lCfgInd. set be set.
to
not
0~7 0 0 RegPeriod
Cdma1XrttCsfbReg
If does not
0 If Cdma1XrttCfgInd
NOT_CFG,
need to
eStateCfgInd.
If be set.
need
ZoneTimer to
Cdma1XrttCsfbReg be set.
must be
is
2.
If set to NOT_CFG,
Cdma1XrttCsfbReg
Cdma1XrttCellRese
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 set.
This
CfgInd parameter
is set to is
NOT_CFG, CFG Cdma1XrttCellRese
RegZone
Cdma1XrttLongCod
Cdma1XrttLongCod
lCfgInd does
set tonot
isdepending
configure) configure) 0 If
optional,
NOT_CFG,
lCfgInd
need to
eStateCfgInd
eStateCfgInd does
be not
set.is
is
CFG,
Cdma1XrttCsfbReg
on
need thetosetting
Cdma1XrttCsfbReg be set. ofset
CellReselCdma200 optional,
to CFG,
Cdma1XrttSpeedSt
CfgInd is depending
set to
0~6 characters None None Cdma1XrttCellRese
TotalZone
2. Ifthe setting does not
0 on
Cdma1XrttLongCod
ateCfgInd
NOT_CFG, must ofbe
lCfgInd.
need to
Cdma1XrttCellResebe set.
Cdma1XrttCfgInd.
eState
set. must be set.
Cdma1XrttCsfbReg
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 If
lCfgInd
This is set to
NOT_CFG, CFG ZoneTimer doesisnot
If
If parameter
Cdma1XrttCfgInd
Cdma1XrttCellRese
configure) configure) 0 CFG,
optional,
is
This set the
to following
depending
CFG,
parameter
Cdma1XrttLongCod
Cdma1XrttCellRese is
need
lCfgInd to is be setset.to
parameters
on the
optional.
eStateCfgInd
lCfgInd setting
Cdma1XrttLongCodis must
Whether
set ofset
is
to be
CellReselCdma200 CFG,
set:
Cdma1XrttSpeedSt
0~7 1 1 eStateCfgInd
to set this
NOT_CFG,
NOT_CFG, must
0 Cdma1XrttTreselect
Cdma1XrttTreselect
ateCfgInd.
be set.
parameter
Cdma1XrttLongCod
Cdma1XrttSpeedSt is
T_RESEL_SF_0DO ion
ion
If must
anddoes be set.
NOT_CFG(Not NOT_CFG(Not CellReselCdma200 Cdma1XrttCfgInd
determined
eState
ateCfgInd by
doesnotthenot
NOT_CFG, CFG
T25, If
Cdma1XrttSpeedSt
configure) configure) 0 is
need set to
parameter to be NOT_CFG,
set.
T_RESEL_SF_0DO Cdma1XrttCellRese
ateCfgInd.
ateCfgInd is set to
Cdma1XrttLongCod
Cdma1XrttSpeedSt
2. If
T_RESEL_SF_0DO
T5, T_RESEL_SF_1DO T_RESEL_SF_1DO CellReselCdma200 lCfgInd
If
CFG, is set to
eStateCfgInd
ateCfgInd.
Cdma1XrttSpeedSt does
T25,
T_RESEL_SF_0DO T0(1.0) T0(1.0) 0 NOT_CFG,
Cdma1XrttCellRese
Cdma1XrttSfMediu
not need toisbe
When
If
ateCfgInd set set.
to
T_RESEL_SF_0DO
T75, Cdma1XrttTreselect
lCfgInd
m must is set
set.to
befollowing
Cdma1XrttSpeedSt
SpeedStateSfCfgIn
CFG, the
T5,
T_RESEL_SF_1DO T_RESEL_SF_0DO T_RESEL_SF_0DO CellReselCdma200 ion
NOT_CFG,
If does notthe need
ateCfgInd
d isbeset
parameters ismust
to CFG, set thetobe
T_RESEL_SF_0DO
T0 T75(0.75) T75(0.75) 0 to
following set.
Cdma1XrttSpeedSt
CFG,
following
set:
T75, parameters
ateCfgInd do
setnot
ismust tobe
Cdma1XrttSfHigh
parameters
Cdma1XrttSfMediu
T_RESEL_SF_1DO
0~11 None None CellReselGeran None
This parameter
need
NOT_CFG,
needs
set:
m and totobe beset: set.is
T0 optional,
Cdma1XrttTreselect
Cdma1XrttSfMediu depending
When
TReselGeranSfMed
Cdma1XrttSfHigh.
on
ion
m the
and
does setting
Cdma1XrttSpeedSt
ium
If and not need of theto
0~7 1 1 CellReselGeran None
This parameter is
SpeedStateSfCfgIn
Cdma1XrttSpeedSt
be set.
ateCfgInd
TReselGeranSfHigh
Cdma1XrttSpeedSt is set to
optional,
d parameter.
ateCfgInd. depending
T_RESEL_SF_0DO .NOT_CFG,
ateCfgInd
on the setting is set of tothe
NOT_CFG(Not NOT_CFG(Not If
NOT_CFG,
T25, CFG CellReselGeran Cdma1XrttSfHigh
If
NOT_CFG,
SpeedStateSfCfgIn the
configure) configure) SpeedStateSfCfgIn
T_RESEL_SF_0DO does
following
d not need to be
SpeedStateSfCfgIn
parameter.
T_RESEL_SF_0DO d is
set.
d is set
set
parameters to
to CFG, do not
T5, T_RESEL_SF_1DO T_RESEL_SF_1DO If
T25, CellReselGeran TReselGeranSfMed
NOT_CFG,
need to be set: the
T_RESEL_SF_0DO T0(1.0) T0(1.0) SpeedStateSfCfgIn
T_RESEL_SF_0DO ium must
following
Cdma1XrttSfMediu be set.
T75, d is set to CFG,
T5, T_RESEL_SF_0DO T_RESEL_SF_0DO If
parameters
m and do not
T_RESEL_SF_1DO CellReselGeran TReselGeranSfHigh
T_RESEL_SF_0DO T75(0.75) T75(0.75) SpeedStateSfCfgIn
need to
Cdma1XrttSfHigh.be set:
T0 must betoset.
T75, d is set
TReselGeranSfMed
If
NOT_CFG,
T_RESEL_SF_1DO ium and
SpeedStateSfCfgIn
TReselGeranSfMed
T0 TReselGeranSfHigh
d
iumis set
does to not need
.NOT_CFG,
to be set.
TReselGeranSfHigh
does not need to be
set.
If
SpeedStateSfCfgIn
d is set to CFG, the
following
0~11 None None CellReselUtran None
This parameter
parameters mustis be
optional,
set: depending
on the setting of the
TReselUtranSfMedi
0~7 1 1 CellReselUtran None
This parameter is
SpeedStateSfCfgIn
um and depending
optional,
d parameter.
TReselUtranSfHigh.
T_RESEL_SF_0DO NOT_CFG(Not NOT_CFG(Not on the setting of the
NOT_CFG, CFG CellReselUtran If
If
T25, configure) configure) SpeedStateSfCfgIn
SpeedStateSfCfgIn
SpeedStateSfCfgIn
T_RESEL_SF_0DO d parameter.
T_RESEL_SF_0DO d
d is
is set
set to
to CFG,
T5, T_RESEL_SF_1DO T_RESEL_SF_1DO If
T25, CellReselUtran TReselUtranSfMedi
NOT_CFG, the
T_RESEL_SF_0DO T0(1.0) T0(1.0) SpeedStateSfCfgIn
T_RESEL_SF_0DO um must be set.
following
T75, d is set to CFG,
T5, T_RESEL_SF_0DO T_RESEL_SF_0DO If
parameters do not
T_RESEL_SF_1DO CellReselUtran TReselUtranSfHigh
T_RESEL_SF_0DO T75(0.75) T75(0.75) SpeedStateSfCfgIn
need to be set:
T0 must betoset.
T75, d is set
TReselUtranSfMedi
If
NOT_CFG,
T_RESEL_SF_1DO
0~11 None None CellSel um
None and
SpeedStateSfCfgIn
TReselUtranSfMedi
T0 TReselUtranSfHigh.
d is set tonot need
um does
-140~-44, step:2 -64 -64 CellSel NOT_CFG,
to
Nonebe set.
TReselUtranSfHigh
does not need to be
0~16, step:2 0 0 CellSel set.
None

0~11 None None CellSiMap None

BOOLEAN_FALSE, BOOLEAN_TRUE( BOOLEAN_TRUE(


CellSiMap None
BOOLEAN_TRUE True) True)
RF8, RF16, RF32,
RF16(16 radio RF16(16 radio
RF64, RF128, CellSiMap None
frames) frames)
RF256, RF512
RF8, RF16, RF32,
RF16(16 radio RF16(16 radio
RF64, RF128, CellSiMap None
frames) frames)
RF256, RF512
RF8, RF16, RF32,
RF32(32 radio RF32(32 radio
RF64, RF128, CellSiMap None
frames) frames)
RF256, RF512
RF8, RF16, RF32,
RF32(32 radio RF32(32 radio
RF64, RF128, CellSiMap None
frames) frames)
RF256, RF512
RF8, RF16, RF32,
RF64(64 radio RF64(64 radio
RF64, RF128, CellSiMap None
frames) frames)
RF256, RF512
RF8, RF16, RF32,
RF64(64 radio RF64(64 radio
RF64, RF128, CellSiMap None
frames) frames)
RF256, RF512
RF8, RF16, RF32,
RF64(64 radio RF64(64 radio
RF64, RF128, CellSiMap None
frames) frames)
RF256, RF512
0~11 None None CellUlpcComm None
AL0, AL04, AL05,
AL06, AL07, AL08, AL07(0.7) AL07(0.7) CellUlpcComm None
AL09, AL1
-127~-96 -105 -105 CellUlpcComm None

-126~24 -67 -67 CellUlpcComm None


DELTAF_2,
DELTAF0, DELTAF0(0dB) DELTAF0(0dB) CellUlpcComm None
DELTAF2
DELTAF1,
DELTAF3, DELTAF3(3dB) DELTAF3(3dB) CellUlpcComm None
DELTAF5
DELTAF_2,
DELTAF0,
DELTAF1(1dB) DELTAF1(1dB) CellUlpcComm None
DELTAF1,
DELTAF2
DELTAF_2,
DELTAF0, DELTAF2(2dB) DELTAF2(2dB) CellUlpcComm None
DELTAF2
DELTAF_2,
DELTAF0, DELTAF2(2dB) DELTAF2(2dB) CellUlpcComm None
DELTAF2
-2~12, step:2 4 4 CellUlpcComm None

MS100_T300,
0~11
MS200_T300, None None UeTimerConst None
MS300_T300,
MS100_T301,
MS400_T300, MS200_T300(200m MS200_T300(200m
MS200_T301, UeTimerConst None
MS600_T300, s) s)
MS300_T301,
MS1000_T300,
MS400_T301,
MS0_T310,
MS1500_T300, MS200_T301(200m MS200_T301(200m
UeTimerConst None
MS600_T301,
MS50_T310,
MS2000_T300 s) s)
MS1000_T301,
MS100_T310,
MS1000_T311,
MS1500_T301, MS200_T310(200m MS200_T310(200m In the Cell MO, if
MS200_T310, UeTimerConst None
FddTddInd is set to
MS3000_T311,
MS2000_T301 s) s)
MS500_T310, CELL_TDD, the
MS5000_T311,
MS1000_T310, In the
MS10000_T311,
MS10000_T311(10 MS10000_T311(10
UeTimerConst In the Cell
following
None Cell MO,
MO, ifthe
MS2000_T310 000ms) 000ms) FddTddInd
value of CellName
constraints is set to
apply
MS15000_T311, CELL_TDD, the of
MS20000_T311, is a string
during the of a
setting
n1, n2, n3, n4, n5, following
MS30000_T311 n5(5) n5(5) UeTimerConst None
maximum
UlCyclicPrefix, of 99
n6, n8, n10 constraints
characters. apply
DlCyclicPrefix, Theand
n1, n2, n3, n4, n6, during the setting
string cannot
SpecialSubframePa be allof
n6(6) n6(6) UeTimerConst None
UlCyclicPrefix,
null characters or
tterns:
n8, n10, n20
DlCyclicPrefix,
contain
(1). any of the
If UlCyclicPrefix and
SpecialSubframePa
following
and DlCyclicPrefix
0~11 None None Cell None
tterns:
characters:
are both setdouble to
(1). If UlCyclicPrefix
quotation
NORMAL_CP, marks ("),
1~99 characters None None Cell and
commas DlCyclicPrefix
(,),
SpecialSubframePa
are both
semicolons
tterns canset be toset to
(;),
NORMAL_CP,
equal
0~11 None None Cell In the signs
SSP4,
None
SSP5
Cell
SpecialSubframePaMO,(=),
or
single
SSP7;
1. This
CsgInd quotation
parameter
must bebe setis
tterns
marks
(2). can only
('),depending
three
If UlCyclicPrefix
optional,
to
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( set toDlCyclicPrefix
SSP4,plus
consecutive
and SSP5
Cell on the setting of
BOOLEAN_FALSE.
BOOLEAN_TRUE False) False) or SSP7;
signs (+++),
are both
UlEarfcnCfgInd.
Currently
(2). thetwo
set
If consecutive
to or
UlCyclicPrefix
more
EXTENDED_CP,
If UlEarfcnCfgInd
eNodeB does not is
NORMAL_CP, NORMAL_CP(Nor NORMAL_CP(Nor and DlCyclicPrefix
Cell blanks,
set
In to
support
the and
SpecialSubframePa
1. If CFG,
CSG
Cell MO,two
UlEarfcnCfgInd or
cells.
EXTENDED_CP mal) mal) are both set
more
tterns
is set
UlEarfcn
DlEarfcn can
to betoset
consecutive
CFG,
must
and beto
EXTENDED_CP,
percentage
SSP3,
UlEarfcn SSP4must signs
orbe
NORMAL_CP, NORMAL_CP(Nor NORMAL_CP(Nor set.
UlEarfcn must be
Cell SpecialSubframePa
(%).
SSP5;
set;
EXTENDED_CP mal) mal) If
setUlEarfcnCfgInd
in accordance is
tterns
1.
(3).
If In canCell
the
IfFreqBand.onlyMO,
UlCyclicPrefix
UlEarfcnCfgInd beisif
set
with to NOT_CFG,
set to
FddTddInd SSP3, isSSP4
set
1~40,64 None None Cell is
setset
UlEarfcn
That to
tois,NOT_CFG,
does
certain notto
or SSP5;
CELL_TDD
EXTENDED_CP
UlEarfcn does and notbe
need to be set.
constraints must
(3).
and
need IfDlCyclicPrefix
UlCyclicPrefix
UlEarfcnCfgInd
to be set. is
NOT_CFG(Not NOT_CFG(Not 2.
met Induring
the Cell theMO, if
NOT_CFG, CFG Cell is
set
is
2. set
to
set
In to
CFG,
to
the Cell
configure) configure) FddTddInd
setting. For is set toif
MO,
details,
EXTENDED_CP
DlEarfcn
NORMAL_CP,
FddTddInd and
CELL_TDD
see
and 3GPP TS set to
isand
DlCyclicPrefix
18000~39649,6533 UlEarfcn
CELL_TDD
UlEarfcnCfgInd must
SpecialSubframePa andbe is
None None Cell 36.104.
is set to
6~65535 set to
tterns the same
set to CFG, setisto
can
UlEarfcnCfgInd be
NORMAL_CP,
value.
SSP4, SSP5
set to CFG,
DlEarfcn and or
0~39649,65336~65 SpecialSubframePa
1.
2. In the Cell
SSP7;
DlEarfcn MO,
CELL_BW_N6, None None Cell UlEarfcn and must be
535 tterns
DlEarfcn
(4). to can
CustomizedBandWi only
and
If UlCyclicPrefix
UlEarfcn be
CELL_BW_N15, set themust
DlBandWidth same be
must
set to
thCfgInd
UlEarfcn
is set
set to toSSP4,must
the same SSP5
be
CELL_BW_N25, value.
be the same asandif
None None Cell or
setSSP7;
to
inthe
NORMAL_CP
value. NOT_CFG
accordance
CELL_BW_N6,
CELL_BW_N50, 3. In
UlBandWidth Cell MO,
(4).
with IfFreqBand.
DlCyclicPrefix isinis
UlCyclicPrefix
DlBandWith not
set
CELL_BW_N15,
CELL_BW_N75, DlEarfcn
each Cell and
MO.
is
setset
That
to to to
is, certain
EXTENDED_CP,
CELL_BW_N25,
CELL_BW_N100 UlEarfcn must be
None None Cell NORMAL_CP
CELL_BW_N50(10
constraints
SpecialSubframePa must and be
CELL_BW_N50, set in accordance
DlCyclicPrefix
M).
met during
tternsFreqBand. the
can be set to is set
CELL_BW_N75, with
to
2. EXTENDED_CP,
DlBandWidth
setting.
SSP3, For or and
details,
CELL_BW_N100 That is,SSP4 certain
SpecialSubframePa
UlBandWidth
see
SSP5. 3GPP TS must
constraints must be
tterns
be set
36.104. can
to only
the samebe
met during the
set to in
value SSP3,
eachSSP4 Cell
setting. For details,
or SSP5.
MO.
see 3GPP TS
36.104.
setting
2.
SSP7;
(5) In
2600 the of Cell MO, if
(2)
<= 1,000<mon < the
(2) 1000:
depending
FddTddInd.
PreambleFmt
If UlCyclicPrefix
CellRadius <= is
RootSequenceIdx
setting
If FddTddInd
smaller
and of
than 4isand
DlCyclicPrefix set
3500:
1,500
can bem:
FddTddInd. set totoa is
to
are CELL_TDD,
HighSpeedFlag
both
RootSequenceIdx set
value
If FddTddIndin the range
SpecialSubframePa
set to
EXTENDED_CP, is set
can
may
of
to 24 be
range
to
CELL_TDD, set
819; to
from any30
tterns
HIGH_SPEED must
SpecialSubframePa
value in the berange set;
or
to
(2) 815;
1000
SubframeAssignme <
If
TheFddTddInd
ULTRA_HIGH_SPE
tterns
of 52 Cell
can
to MOs
795;be is
set set
under to
(3) 1,500bemset.
CellRadius
nt must <=<
to
the
ED, CELL_FDD,
SSP3,
(6) same
the
3500 following
SSP4<eNodeB or
CellRadius
1500:
If FddTddInd <=is set
0~255 None None Cell SpecialSubframePa
must
constraints
SSP5;
CellRadius each have on a
2,000 m: <=
RootSequenceIdx
to CELL_FDD,
ttern
unique
CellRadius
(3)
4300: If does value not
and
UlCyclicPrefix ofneed
RootSequenceIdx
can beset.set to a
SubframeAssignme
to
is be
CellId.
RootSequenceIdx
set to
RootSequenceIdx
0~503 None None Cell may
value
None
nt does range
in not
the from
range
need 36
2. Inbethe
apply:
EXTENDED_CP
can set Cell
to MO,toif
any
to
of
be 809;
30
set. to 815;
FddTddInd
(1).
and
value 1DlCyclicPrefix
min <=the isrange
set to
(4)In1500
(3)
2. 2,000
the <m<=
Cell <MO,
1~32 1 1 Cell CELL_TDD,
CellRadius
is
of set
None to
64 to 789;<= the
CellRadius
CellRadius
1,000
NORMAL_CP,
(7) 4300 m: < <=
SubframeAssignme
following
2,600
2000:
nt can m:
only be set
constraints
RootSequenceIdx
SpecialSubframePa
CellRadius apply
<=
CELL_DEACTIVE,
CELL_UNBLOCK, CELL_DEACTIVE( CELL_DEACTIVE( RootSequenceIdx
RootSequenceIdx
to SA0, SA1, SA2,
Cell during
may
None
tterns
5500: the
range
can be setting
from set24 of
to
CELL_ACTIVE
CELL_HIGH_BLOC Deactivated) Deactivated) may
can
SA3 range
be
or set
SA5 from
to if a 42
UlCyclicPrefix,
to 819;
SSP4,
K, to 803;inSSP5
RootSequenceIdx
value
FddTddInd the
or
isrange
set to
CELL_UNBLOCK(U CELL_UNBLOCK(U DlCyclicPrefix,
(2).
SSP7;
can 1,000
be set mto <any and
CELL_MIDDLE_BL Cell (5)
of
None362,600
CELL_TDD. to m
809; <
nblock) nblock) SpecialSubframePa
CellRadius
(4)
value If parameter <=
UlCyclicPrefix
in the range
OCK, This
CellRadius
(4)
3. In2000the < <=
Cell MO, if
tterns:
1,500
is
of set
76 to
tom: 777;
CELL_LOW_BLOC needs
3,500
CellRadius
FddTddInd to
m: be <=
is set
1~1440
CELLINFO_INIT_F 60 60 Cell
(1). If
specified
UlCyclicPrefix
RootSequenceIdx
NORMAL_CP
(8) 5500 <onlythe
RootSequenceIdx andto
when
K 2600:
CELL_TDD,
and
may DlCyclicPrefix
range from
AIL, DlCyclicPrefix
CellRadius
the
maymiddle <= is 30
range priority
RootSequenceIdx
following from set
52
are
to both
815;
EXTENDED_CP,
6800: set to
ALLOC_RRU_FAIL,
CELL_FDD, block
to
can 795; is performed
be setmto
ALLOC_BBI_FAIL, None None Cell constraints
NORMAL_CP,
(3). 1,500
SpecialSubframePa
RootSequenceIdx <a
apply
CELL_TDD (6)
value
during3,500 inthe msetting
the <
range of
SpecialSubframePa
CellRadius
tterns can be <=any
ALLOC_IDX2_FAIL
SA0, SA1, SA2, can beto
CellRadius
of 42
UlCyclicPrefix,set
803; <=set to
to
tterns
2,000
SSP3,
value can
m:
inSSP4
thebe set
or to
,SA3,
RES_CHK_FAIL, 4,300
(5) 2600 m: < range
dB-24,SA4, SA5,
dB-22,
UEM_CFG_FAIL, dB- None None Cell DlCyclicPrefix,
SSP4, SSP5
RootSequenceIdx
SSP5.
of 90 to
RootSequenceIdx 765; orand
SA6
SSP0, SSP1, CellRadius
SubframeAssignme
SSP7;
may range <=MO,
20, dB-18,
RRU_CFG_FAIL,dB-16, 5.
(9)
may In
3500:
nt: 6800the
range < from 36
Cellfrom
64if
SSP2, SSP3,
dB-14, dB-12, dB- (2).
to 809;If
FddTddInd
CellRadius UlCyclicPrefix
<= to
is set
BBI_CFG_FAIL,
dB-24, dB-22, None None Cell to 789;
RootSequenceIdx
(1). If PreambleFmt
SSP4,
10, dB-8, dB-6,dB-
SSP5,
TX_BRANCH_NOT dB- and
(4).
CELL_TDD
8600:
(7)
DlCyclicPrefix
2,000
4,300
m
m and
<
<a
20,
SSP6, dB-18, dB-16,
SSP7, SSP8 Cell radius <= 1400 can
is
areset betoset
both
CellRadius
PreambleFmt setto
0, <= tois set
5, dB-4,
_USABLE, dB-3, dB-2, RootSequenceIdx
CellRadius
dB-14, dB-12, dB- m: Preamble value
4,bein
SubframeAssignme
EXTENDED_CP,
2,600
to m: the<= range
dB-1, dB0,
RX_BRANCH_NOT dB1, dB0(0dB) dB0(0dB) Cell None
can
5,500 m:set to any
10, dB-8, dB-6, dB- formats 0 to 3 are of
nt 52
can to be795;
SpecialSubframePa
RootSequenceIdx set to
dB2, dB3,
_USABLE, dB4, value in the
RootSequenceIdx range
5, dB-4, dB-3, dB-2, applicable to an (6)
SA0,
tterns
may
must 3500 SA1,
can
range
be < beSA2,
from
smaller set42 to
dB5, dB6,
CELL_FREQ_ERRdB8, of
may 116 toSA5;
range 751;from 76
dB-1, dB0, dB1, dB0(0dB) dB0(0dB)
FDD cell, preamble Cell CellRadius
SA3
None
SSP3,
to
than803; or
or SSP4
equal <=or to
dB10,
OR, dB12, dB14, (10)
to 777; 8600 <
dB2, dB3, dB4, formats 0 to 4 are 4300:
(2).
SSP5;
(5).
137. If PreambleFmt
2,600 m<= <
dB16, dB18,
CELL_ACT_SUCC dB20, CellRadius
(8) 5,500 m <
dB5, dB6, dB8, applicable to a TDD RootSequenceIdx
is set
(3).
6. In to 1,
Ifthe
CellRadius UlCyclicPrefix
Cell <=MO, if
dB22,
ESS,
0~837 dB24
NO_INFO, None None Cell 10600:
CellRadius <=a
dB10, dB12, dB14, cell; can
is setbeto
3,500
FddTddInd m:set to
SubframeAssignme is set to
S1_LINK_DOWN,
LOW_SPEED, RootSequenceIdx
6,800
value
nt can m:
inbe the
set range
to
dB16, dB18, dB20, 1400 m < Cell EXTENDED_CP
RootSequenceIdx
CELL_TDD
ALLOC_CONTAINE
HIGH_SPEED, LOW_SPEED(Low radius
LOW_SPEED(Low can
of
SA0,64 be
RootSequenceIdx
to
SA1 set
789;ortoand any
SA3;
dB22, dB24 <= 14,500 m: Cell and
may DlCyclicPrefix
range
PreambleFmt from is 52
set
R_FAIL,
ULTRA_HIGH_SPE speed cell flag) speed cell formats
flag) 0 value
may
(7) 4300 in
range the range
from 90
Preamble (3).
is
to set
of 795;
4,
136 toto <729;
If PreambleFmt
MPT_NOT_USABL
ED to 3 are applicable; to 765;to 2, <=
CellRadius
is set
NORMAL_CP,
(6). 3,500
SpecialSubframePa
1. In6,800
the Cell m<
E,
0~4 0 14,500 m < Cell Cell
(11)
(9)
5500: 10600
SubframeAssignme m<<MO,
SpecialSubframePa
CellRadius
tterns must
CustomizedBandWi
CellRadius <=
be
<=
GET_LICENSE_FAI radius <= 29,500 m: RootSequenceIdx
nt can can be set to
tterns
4,300
larger
dthCfgInd
13200: m:
than be SSP4.
must setbeto
L, Preamble formats 1 8,600
can
SA0, be m:
SA1 set orto a if
SA3;
SSP4,
set to SSP5
RootSequenceIdx
7. In the Cell
NOT_CFG
RootSequenceIdx or
MO, if
TDD_CELL_FRAM
1~100000 10000 10000
to 3 are applicable; Cell value
(4). in thefrom
Ifrange
PreambleFmt range
SSP7;
may
FddTddInd
DlBandWidth
can be set is
to set
is
any 64to
not
E_CFG_ERR, may
of 76 range fromif116
29,500 m < Cell is
In
to
setset
(4).the
789;If to
CELL_TDD,
value to
777;
Cell3, MO,
UlCyclicPrefix
in the the
range
CELL_POWER_EX NOT_CFG(Not NOT_CFG(Not
radius <= 77,300 m: to
(8) 751;
5500
SubframeAssignme <
NOT_CFG, CFG Cell CustomizedBandWi
is set
(7). toto 707;
4,300
following
CELL_BW_N50. m<
CEED_RRU_CAP, of
(10)168 8,600
CellRadius m <
CELL_INST_UNIN
CELL_NO_OP, configure) configure)
Preamble formats 1 nt can
dthCfgInd
NORMAL_CP
CellRadius
constraints
2. In the beCellis<=
set <= toand
set
apply
MO, to
INTRA_BBI_PREA
STALL,
CELL_SETUP_ACT (12)
6800:
SA0 13200
CellRadius
In the or Cell
SA3; <
<=
MO, ifset
and 3 are CFG,
DlCyclicPrefix
5,500
during m:
setting
CustomizedBandWi is
of
MBLEFMT_CFG_E
,CELL_INST_UEM_ CellRadius
10,600
CustomizedBandWi
RootSequenceIdx
(5). m: <=
If PreambleFmt
98 98 applicable;
98 Cell CusomizedULBand
to EXTENDED_CP,
RootSequenceIdx
PreambleFmt
dthCfgInd must and be
RR,
CFGING,
CELL_SETUP_UBL 17200:
RootSequenceIdx
dthCfgInd
can
is set beto 4, isto
set set
a theto
77,300 m < Cell Width must
SpecialSubframePa
may range
SubframeAssignme
set to NOT_CFG be
from 76if
INTRA_BBI_CYCLI
,CELL_INST_RRU_ RootSequenceIdx
may
CFG,
value range
in
SubframeAssignme the from
range
radius <= 100,000 same
tterns
to
nt: 777;
FddTddInd as
can be is set
set to
to
CPREFIX_CFG_ER
CFGING,
CELL_SETUP_HE 98 98 98 Preamble format Cell can
136 be
to
CusomizedULBand
of
nt 90
can tobeset
729;
765;
setto any
to
m: CusomizedDLBand
SSP3,
(8).
(1) If5,500
CELL_TDD. SSP4 mrange
PreambleFmt <or
R,
CELL_INST_BBI_C
ALCHK, value
(11)
Width
(9)
SA0, 6800 in
10,600
must
SA1, the
< m <the
be
SA2,
3 is applicable. Width.
SSP5.
CellRadius
is set toto0,659; <=
BBI_CELL_NUM_O
FGING,
CELL_SETUP_141, of 204
CellRadius
same
CellRadius
SA3 orasSA5. <=
<=
None None Cell 3. In 17200
6,800 them:Cell
SubframeAssignme
None
(13) MO, if
VER,
CELL_INST_RECF
CELL_SETUP_UL 13,200 m: <
CusomizedDLBand
8600:
FddTddInd
RootSequenceIdx
nt can
CellRadius be set is
<=to set to
CELL_EXCEED_D
GING,
WIDESCAN, RootSequenceIdx
Width.
RootSequenceIdx
CELL_TDD
may
SA0,
21500: range
SA1, and
from
SA2, 90
SP_SPEC,
CELL_INST_DELE
CELL_DEL_BLK_L may
can range
be set from
to ais set
None None Cell None
PreambleFmt
to
SA3 765; or
RootSequenceIdx SA5;
MULTI_CARRIER_ 168
value toin707;the
TING,
OW, to
(9).
(2)
can 4,If6,800
be mtorange
PreambleFmt
set <
CELL_TOPO_NOT
CELL_INST_NORM
CELL_DEL_BLK_M (12)
of 116 13,200
to 751; many <
SpecialSubframePa
CellRadius
is set
value to
in 1,
the <=range
_SPT,
0~32
ID, characters
AL, None None Cell CellRadius
None
(10) 8600 < <=
tterns
of 264must
8,600 m:
SubframeAssignme
to be
BF_ALGO_NOT_S
CELL_INST_BARR
CELL_DEL_BLK_H 17,200
CellRadius m:629; <=to
larger
(14)can than
RootSequenceIdx
nt be
21500 < set SSP4.
UPPORT,
ED
IGH, RootSequenceIdx
10600:
BBI_MIMOCELL_B None None Cell may
SA0,
None
CellRadiusrange
SA1 or from
<=SA3; 116
CELL_DEL_NOUS may range
RootSequenceIdx from
W_ERR, to
(3) 751;
27800:If PreambleFmt
204 be
can to 659;
ER,
MIMOCELL_BW_M (10).
is toset
8,600
set17,200
RootSequenceIdx
(13) 2, to m a<
m <
CELL_DEL_DEA,
0~32 characters None None Cell value
None
CellRadius in
SubframeAssignme the <=range
IX_ERR,
CELL_DEL_RMV, can be to
CellRadius
of 136 set729;to
<=any
MIMOCELL_TOPO 10,600
nt caninbe
value m: setrange
the to
CELl_DEL_HEALC 21,500
(11) 10600 m: < SA3;
_MIX_ERR, RootSequenceIdx
SA0,
of SA1
328 to 561; or
HK, RootSequenceIdx
CellRadius <=
may
(4) range from
DOUBLERRU_10M
CELL_DEL_UNHE mayIf27800
(15)
13200:
PreambleFmt
range <
from
BL_BW_MIX_ERR, 136
is to
settoto629;
CellRadius 729;
3, <=
AL, 264
RootSequenceIdx
DOUBLERRU_TOP (11). 10,600 m <
SubframeAssignme
32800:
(14) be
can 21,500setset to m<
CELL_DEL_SETUP
O_MIX_ERR, CellRadius
nt can be
RootSequenceIdx <=a to
_FAIL, CellRadius
value in the <=range
MUTICHAINCELL_ 13,200
SA0
can or
be to m:
SA3;
set to any
27,800
of m:707;
CELL_DEL_141_D (5)168
RootSequenceIdx
If PreambleFmt
CELL_SETUP_UL
WIDESCAN,
CELL_PWRSAVE_
CELL_DEL_BLK_L
UNINSTALL,
OW,
CELL_PWRSAVE_
CELL_DEL_BLK_M
STAR_BASIC_TYP
RFSHD,
ID,
E,
CELL_PWRSAVE_
CELL_DEL_BLK_H
HOT_BACKUP_TY
CELLSHD,
IGH,
PE,
CELL_PWRSAVE_ None None Cell None
CELL_DEL_NOUS
COLD_BACKUP_T
LOWPWR_CELLU
ER,
YPE,
SEDPWRRDU,
BBI_SLOT_0,
CELL_DEL_DEA,
MULTI_CHAIN_TY
CELL_PWRSAVE_
BBI_SLOT_1, None None Cell None
CELL_DEL_RMV,
PE,
LOWPWR_RSPWR
BBI_SLOT_2,
CELl_DEL_HEALC
STAR_DOUBLE_R
RDU,
BBI_SLOT_3,
HK,
RU_TYPE,
CELL_PWRSAVE_ None None Cell None
BBI_SLOT_4,
CELL_DEL_UNHE
CHAIN_LEVEL2_T
LOWPWR_RFSHD,
BBI_SLOT_5,
AL,
YPE,
CELL_PWRSAVE_
BBI_SLOT_INVALI None None Cell None
CELL_DEL_SETUP
LOAD_SHARE_TY
LOWPWR_CELLS
D
_FAIL,
PE,
HD,
CELL_DEL_141_D
MIMO_MUTUAL_AI
AUTO_PWROFF_
0~255 None None Cell None
EL,
D_TYPE,
ONTIME
CELL_DEL_ULWID
MULTI_SECTOR_S
0~255
ESCAN,
TAR, None None Cell None
CELL_DEL_CELLN
MULTI_SECTOR_C
OACCESSALM
HAIN,
0~11
120ms, 240ms, None None CellDLIcicMcPara None
MUX_NORMAL_TY
480ms,
PE, 640ms,
1024ms, 2048ms,
MUX_DOUBLE_TY 5120ms 5120ms CellDLIcicMcPara None
5120ms, 10240ms,
PE, INVALID_TYPE
1min, 6min, 12min,
30min,
1~8 60min 8 8 CellDLIcicMcPara None

r1, r2, r4, r8, r16,


Infinity(Infinity) Infinity(Infinity) CellDLIcicMcPara None
r32, r64, Infinity
SAME_AS_TRIG_
BOTH BOTH CellDLIcicMcPara None
QUAN, BOTH

RSRP, RSRQ RSRP RSRP CellDLIcicMcPara None

0ms, 40ms, 64ms,


0~15,
80ms, step:0.5
100ms, 4 4 CellDLIcicMcPara None
128ms, 160ms,
256ms, 320ms,
640ms 640ms CellDLIcicMcPara None
480ms, 512ms,
640ms, 1024ms,
1280ms, 2560ms,
-15~15, step:0.5 -10 -10 CellDLIcicMcPara None
5120ms

0~11 None None CellLowPower None

OFF, ON OFF(Off) OFF(Off) CellLowPower None

OFF, ON OFF(Off) OFF(Off) CellLowPower None

00:00:00~23:59:59 00:00:00 00:00:00 CellLowPower None

00:00:00~23:59:59 06:00:00 06:00:00 CellLowPower None

0~1440 120 120 CellLowPower None

0~1440 120 120 CellLowPower None

0~1440 120 120 CellLowPower None


10~100 50 50 CellLowPower None

-10~0 -1 -1 CellLowPower None

1~1440 5 5 CellLowPower None

0~11 None None CellRacThd In


Nonethe CellRacThd
MO,
1. In the
GoldServiceArpThd
CellRacThd MO,
1~15 5 5 CellRacThd In
mustthebeCellRacThd
smaller
the
MO, sum of
than
1. In the
Qci1CongThd and
GoldServiceArpThd
SilverServiceArpTh
CellRacThd MO,
1~15 10 10 CellRacThd CongRelOffset
1.
mustIn the
be of
smaller
d.
the
must sum
be smaller
CellRacThd MO,
than
1. In the
NewCopperService
than
the Qci1HoThd.
sum of MO,
SilverServiceArpTh
CellRacThd
10~99 90 90 CellRacThd Offset
2. Insum
theand
NewCopperService
d.
the
Qci2HoThd of
CellRacThd
1. In the
Offset and must
NewCopperService MO, be
smaller
the sum
CellRacThd
Qci4HoThd than or be
of must
MO,
10~99 90 90 CellRacThd Offset
equal and
to 100.
NewCopperService
the sumthan
smaller
Qci3HoThd of must
or be
2. In the
Offset and
Qci4CongThd
equal to 100.orand
smaller
CellRacThd than MO,
10~99 90 90 CellRacThd Qci1HoThd
equal 100.must be
CongRelOffset
2. In the
to of
the
must sum
smaller bethan
CellRacThd or
smaller
MO,
2. In the
Qci2CongThd and
1.
than
the Insum
equal the
to 100.
Qci4HoThd.
of
CellRacThd
CongRelOffset
In the MO,
CellRacThd
10~99 90 90 CellRacThd CellRacThd
2. Insum
the of
NewCopperService MO,
the
must
MO, be smaller
NewSilverServiceOf
CellRacThd
Offset and MO,
Qci3CongThd
than Qci2HoThd.
NewGoldServiceOff and
fset
the mustofbemust
sum
Qci3HoThd smaller
be
0~90 5 5 CellRacThd CongRelOffset
set must be smaller
than or equal
NewCopperService
smaller than to
or
must
than beequal
or smaller
Offset
equal
than to 100. to
NewCopperService
and
Qci3HoThd.
NewSilverServiceOf
Offset.
Qci4HoThd
3. In the must be
0~90 5 5 CellRacThd fset.
2.
1. In thethan MO,
smaller
CellRacThd or
CellRacThd
equal
the sum 100.MO,
to of
0~90 5 5 CellRacThd NewGoldServiceOff
the sum of
NewCopperService
In the CellRacThd
1.
set Inmust
the
Qci2CongThd be smaller
Offset
MO,
1. In the
CellRacThd
and
sum ofand
MO,
than or equal
CongRelOffset
Qci2HoThd must
Qci1CongThd
CellRacThd to
MO,andbe
0~99 65 65 CellRacThd the sum of
NewSilverServiceOf
must be smaller
smaller
the In the
sum than
CongRelOffset
1. of or
Qci3CongThd
fset.
than Qci2HoThd. and
equal
must to less
be
CellRacThd
Qci2CongThd 100.MO,
than
and
CongRelOffset
2. Insum
the of
0~99 65 65 CellRacThd 4.
Qci1HoThd.
the
CongRelOffset
must be smaller
CellRacThd
Qci4CongThd
must MO,
be smaller and
than
the Qci3HoThd.
sum of
CongRelOffset
than
2.
1. In the
0~99 65 65 CellRacThd Qci2CongThd
NewCopperService
must be smaller
CopperGbrCongPro and
CellRacThd
CongRelOffset
Offset and MO,
than
the Qci4HoThd.
portion.
sum
value ofof must be
must
In the be
Qci1HoThd
2. In smaller
CellRacThd
the
0~99 65 65 CellRacThd Qci3CongThd
GoldGbrCongPropo
than
MO, thethan value and
smaller
CellRacThd orof
MO,
CongRelOffset
rtion must be
CopperGbrCongPro
GoldGbrCongPropo larger
equal
the sumto of
100.
must
than
portion.
rtion beequal
or
must smallerto that
be larger
1~100 90 90 CellRacThd 5. In the
Qci4CongThd
Qci3CongThd and
than
of
than or equalMO, to that
CellRacThd
CongRelOffset
CopperGbrCongPro
SilverGbrCongProp
of
NewSilverServiceOf
must be smaller
portion.
ortion.
SilverGbrCongProp
1~100 90 90 CellRacThd fset must be smaller
than
2. In
ortion.the
than or equal to
CopperGbrCongPro
CellRacThd MO,
In the CellRacThd
NewCopperService
portion.
1~100 90 90 CellRacThd the
MO, value of
In the
Offset.
3. the value of
SilverGbrCongProp
GbrRbUsedHighTh
CellRacThd MO,
ortion
In
d the must
must be
CellRacThd
be greater
0~100 95 95 CellRacThd the
larger
MO, sum of
than or equal
than or equal to
Qci4CongThd that
and
to that of
GbrRbUsedHighTh
of
CongRelOffset
CopperGbrCongPro
d must be greater
0~100 90 90 CellRacThd GbrRbUsedLowThd
must be smaller
portion.
than
.than or equal to that
of
CopperGbrCongPro
GbrRbUsedLowThd
1~15 10 10 CellRacThd None
portion.
.
4. In the
CellRacThd MO,
the value of
SilverGbrCongProp
ortion must be
larger than or equal
to that of
CongRelOffset
must be less than
Qci3HoThd.
Set the parameter 4. In the
based on actual CellRacThd MO,
service the sum of
requirements. The Qci4CongThd and
recommended CongRelOffset
0~50 20 20
values are CellRacThd
must be less than
described as Qci4HoThd.
follows: 5. In the
1~15 5 5
FDD: CellRacThd None
In the CellRacThd
CellRacThd MO,
For a cell with a 1.4 MO, the value
the sum of of
10~100 95 MHz
95 bandwidth, a CellRacThd UlRbHighThd
Qci2CongThd and must
value in the range In
be the CellRacThd
larger than that
CongRelOffset
of 0 to 560 is MO,
of the value of
UlRbLowThd.
must be less than
10~100 95 95
recommended; CellRacThd DlRbHighThd must
CopperGbrCongPro
In the CellRacThd
For a cell with a 3 be larger than that
portion.
MO, the value of
MHz bandwidth, a of DlRbLowThd.
10~100 90 90 CellRacThd 6. In the
UlRbHighThd must
value in the range In
of 0 to 1800 is bethe CellRacThd
CellRacThd
larger MO,
than that
MO,
the the value
sum of
of UlRbLowThd. of
10~100 90 recommended;
90 CellRacThd DlRbHighThd
Qci3CongThd mustand
For a cell with a 5 be larger than that
CongRelOffset
MHz bandwidth, a of DlRbLowThd.
must be less than
0~9000 3000 value in the range CellRacThd None
CopperGbrCongPro
of 0 to 3000 is portion.
recommended; 7. In the
0~11 None None
For a cell with a 10 CellRfShutdown None
CellRacThd MO,
MHz bandwidth, a the sum of
OFF, ON OFF(Off) value
OFF(Off)in the range CellRfShutdown None
Qci4CongThd and
of 0 to 3000 is CongRelOffset
recommended; must be less than
00:00:00~23:59:59 00:00:00 For a cell with a 15
00:00:00 CellRfShutdown None
CopperGbrCongPro
MHz bandwidth, a portion.
value in the range
00:00:00~23:59:59 06:00:00 06:00:00
of 0 to 6000 is CellRfShutdown None
recommended;
0~7 3 For
3 a cell with a 20 CellRfShutdown None
MHz bandwidth, a
value in the range
0~11 None of 0 to 6000 is
None CellShutdown None
recommended;
TDD: For a TDD
OFF, ON OFF(Off) OFF(Off)
cell, a value in the CellShutdown None
range of 0 to 6000
00:00:00~23:59:59 00:00:00 is recommended.
00:00:00 CellShutdown None

00:00:00~23:59:59 06:00:00 06:00:00 CellShutdown In the


None
CellShutDown MO,
the sum of
0~100 20 20 CellShutdown In the
DlPrbThd and
CellShutDown
DlPrbOffset must MO,
the
be sum of
less than or
0~100 20 20 CellShutdown In the
DlPrbThd and
equal to 100.
CellShutDown MO,
DlPrbOffset must
the
be sum of
smaller than or
0~100 20 20 CellShutdown In the
UlPrbThd and
equal to 100.
CellShutDown MO,
UlPrbOffset must
the sum of
be less than or
0~100 20 20 CellShutdown UlPrbThd and
equal to 100.
UlPrbOffset must
be less than or
0~11
120ms, 240ms, None None CellULIcicMcPara None
equal to 100.
480ms, 640ms,
1024ms, 2048ms,
5120ms 5120ms CellULIcicMcPara None
5120ms, 10240ms,
1min, 6min, 12min,
30min,
1~8 60min 8 8 CellULIcicMcPara None
r1, r2, r4, r8, r16,
Infinity(Infinity) Infinity(Infinity) CellULIcicMcPara None
r32, r64, Infinity
SAME_AS_TRIG_ SAME_AS_TRIG_
SAME_AS_TRIG_
QUAN(Same as QUAN(Same as CellULIcicMcPara None
QUAN, BOTH
Trig Quan) Trig Quan)
RSRP, RSRQ RSRP RSRP CellULIcicMcPara None

0ms, 40ms, 64ms,


0~15, step:0.5
80ms, 100ms, 4 4 CellULIcicMcPara None
128ms, 160ms,
256ms, 320ms,
640ms 640ms CellULIcicMcPara None
480ms, 512ms,
640ms, 1024ms,
1280ms, 2560ms,
-15~15, step:0.5 -10 -10 CellULIcicMcPara None
5120ms
ULSCH_STRATEG
0~11
Y_EPF, None None CellUlschAlgo None
ULSCH_STRATEG
Y_MAX_CI, ULSCH_STRATEG ULSCH_STRATEG
ADAPTIVE_HARQ_ CellUlschAlgo None
ULSCH_STRATEG Y_EPF(EPF) Y_EPF(EPF)
SW_ON,
Y_PF, ADAPTIVE_HARQ_ ADAPTIVE_HARQ_
ADAPTIVE_HARQ_
ULSCH_STRATEG SW_SEMI_ON(Se SW_SEMI_ON(Se CellUlschAlgo None
SW_OFF,
Y_RR miOn) miOn)
ADAPTIVE_HARQ_
0.01~0.99,
SW_SEMI_ON 10 10 CellUlschAlgo None
step:0.01

0~1, step:0.01 50 50 CellUlschAlgo None

1~10 5 5 CellUlschAlgo None

If UlIcicFreqSwitch
45~1500 80 80 CellUlschAlgo None
is set to ON,
HOPPING_OFF,
UlHoppingCfg does
HOPPING_TYPE1,
HOPPING_OFF(Ho HOPPING_OFF(Ho not take effect. In
HOPPING_TYPE2, CellUlschAlgo
pping off) pping off) this case, the value
HOPPING_TYPE2_
of UlHoppingCfg is
RANDOM
0~100 0 0 CellUlschAlgo HOPPING_OFF
None by
default.

0~11 None
RachAdjSwitch:Off, None
RachAdjSwitch:Off CellAlgoSwitch None
RachAdjSwitch,
HoRaSwitch:On, HoRaSwitch:On
HoRaSwitch,
UnsyncRaSwitch:O UnsyncRaSwitch:O
UnsyncRaSwitch, CellAlgoSwitch None
n, n
In ultra-high-speed
MaksIdxSwitch,
MaksIdxSwitch:Off, MaksIdxSwitch:Off
scenarios, the
BackOffSwitch
SrsSubframeRecfS SrsSubframeRecfS SrsSubframeRecfS
BackOffSwitch:Off BackOffSwitch:Off
recommended CellAlgoSwitch None
witch witch:On witch:On
value of
PucchSwitch is
PucchSwitch PucchSwitch:On CellAlgoSwitch None
OFF.
In other scenarios,
AqmAlgoSwitch AqmAlgoSwitch:Off the recommended
AqmAlgoSwitch:Off CellAlgoSwitch None
value of
CqiAdjAlgoSwitch:O CqiAdjAlgoSwitch:O
PucchSwitch is ON.
CqiAdjAlgoSwitch,
n, n CellAlgoSwitch None
StepVarySwitch
StepVarySwitch:Off StepVarySwitch:Off
OFF, ON OFF(Off) OFF(Off) CellAlgoSwitch None

Dynamic Adjust Dynamic Adjust


DynAdjVoltSwitch CellAlgoSwitch None
Voltage Switch:Off Voltage Switch:Off
UL_SWITCH, It is recommended
LCEM_RAC_ALG_ that
dlCacSwitch:Off, dlCacSwitch:Off
DL_PREDICT_SWI InterFreqMlbSwitch
ulCacSwitch:Off, ulCacSwitch:Off
TCH, be set to OFF when
dlCacPredictSwitch: dlCacPredictSwitch:
LCEM_RAC_ALG_ the
Off, Off cell load is light
UL_PREDICT_SWI in an early stage of
ulCacPredictSwitch:
IntraFreqActiveMlb ulCacPredictSwitch:
TCH, network
Off,
Switch:Off, Off
LCEM_RAC_ALG_
IntraFreqActiveMlb deployment (that is,
GbrUsedPRbCheck
InterFreqMlbSwitch: GbrUsedPRbCheck
GBR_USAGE_SWI
Switch, the CellAlgoSwitch None
Switch:Off,
Off, Switch:Off cell
average
TCH,
InterFreqMlbSwitch, load is lower than
dlLdcSwitch:Off,
UtranMlbSwitch:Off, dlLdcSwitch:Off
LCEM_RAC_ALG_
UtranMlbSwitch, 50%) and there is
ulLdcSwitch:Off,
GeranMlbSwitch:Off ulLdcSwitch:Off CellAlgoSwitch None
DL_LDC_SWITCH,
GeranMlbSwitch, PdschSpsPcSwitch: no obvious
PdschSpsPcSwitch:
CloseLoopSpsSwitc
PdschSpsPcSwitch,
LCEM_RAC_ALG_ ,LdcDrbRelSwitch:O
CloseLoopSpsSwitc LdcDrbRelSwitch:O
CloseLoopSpsSwitc
CdmaMlbSwitch,
h, Off,
ff,
h:Off, imbalance
Off
ff
h:Off in the
PhichInnerLoopPcS
UL_LDC_SWITCH, CdmaMlbSwitch:Off
IntraFreqIdleMlbSwi PhichInnerLoopPcS cell loads (that
PhichInnerLoopPcS is, CellAlgoSwitch None
InnerLoopPuschSwi
witch,
LCEM_LDC_ALG_ ,PreemptionSwitch:
InnerLoopPuschSwi PreemptionSwitch:
InnerLoopPuschSwi
tch
tch, witch:Off,
Off
tch:On, the
Off load difference
witch:Off
tch:On
PdcchPcSwitch
REL_DRB_SWITC IntraFreqIdleMlbSwi
PhSinrTarUpdateS PdcchPcSwitch:Off
PhSinrTarUpdateS between cells is
PdcchPcSwitch:Off
PhSinrTarUpdateS
H, tch:Off CellAlgoSwitch None
witch, witch:Off, lower
witch:Off the
than
LCEM_RAC_ALG_ related threshold).
InnerLoopPucchSwi InnerLoopPucchSwi InnerLoopPucchSwi
PREEMPTION_SW It is recommended
tch,
BfSwitch tch:On,
BfSwitch:Off tch:On
BfSwitch:Off CellAlgoSwitch None
ITCH that
OiSinrTarUpdateSw OiSinrTarUpdateSw OiSinrTarUpdateSw
FreqSelSwitch:Off, SpsSchSwitch:Off
InterFreqMlbSwitch
FreqSelSwitch:Off
itch
FreqSelSwitch, itch:Off
SpsSchSwitch:Off, itch: Off
ServiceDiffSwitch:O SinrAdjustSwitch:O
be set to ON when
ServiceDiffSwitch:O CellAlgoSwitch None
SpsSchSwitch,
ServiceDiffSwitch SinrAdjustSwitch:O
ff n
the cell load is
ff
SinrAdjustSwitch, n,
PreAllocationSwitch
heavy (that is, the
PreAllocationSwitch PreAllocationSwitch
:On
average load in the CellAlgoSwitch None
, UlVmimoSwitch, :On,
UlVmimoSwitch:Off
cell exceeds
TtiBundlingSwitch, UlVmimoSwitch:Off,
TtiBundlingSwitch:
InterFreqMlbThd)
Im2IcSwitch
OFF, ON TtiBundlingSwitch:
OFF(Off) OFF(Off) CellAlgoSwitch None
Off
and there is an
FreqPriorIFHOSwitc Off, Im2IcSwitch:Off
FreqPriorIFHOSwitc FreqPriorIFHOSwitc
Im2IcSwitch:Off
imbalance in the
h, h:Off, It is loads
h:Off
cell recommended
(that is,
that eachdifference CellAlgoSwitch None
FreqPriorIFBlindHO FreqPriorIFBlindHO FreqPriorIFBlindHO
the load
Switch Switch:On neighboring
Switch:On
between cells cell
0~11 None uses
None
exceeds a unique band
the related CellDlIcic None
division
threshold). scheme. If
MODE1(DL band this requirement
It is recommended
MODE1, MODE2,
division scheme cannot
that be met, let CellDlIcic None
MODE3
No.1) the neighboring
UtranMlbSwitch,
cells that have
GeranMlbSwitch
0~11 None None
weakest mutual CellDlpcPdcch None
and
interference
CdmaMlbSwitch use the
be
-15~15, step:0.1 -30 same band division
-30set to OFF when
all CellDlpcPdcch None
scheme.
the cell load is light
in an early stage of
0~11
PA_NEG6, None None
network CellDlpcPdsch None
PA_NEG4DOT77, deployment (that is,
PA_NEG3, the average cell
PA_NEG6, PA_NEG6(-6) PA_NEG6(-6) CellDlpcPdsch None
PA_NEG1DOT77, load is lower than
PA_NEG4DOT77,
PA_0, PA_1, PA_2, 70%).
PA_NEG3,
PA_3 PA_NEG1DOT77(- PA_NEG1DOT77(-
It is recommended CellDlpcPdsch None
PA_NEG1DOT77, 1.77) 1.77)
that
PA_0, PA_1, PA_2,
UtranMlbSwitch,
PA_3
0~11 None None CellDlpcPhich None
GeranMlbSwitch
and
-15~15, step:0.1 0 CdmaMlbSwitch
0 be CellDlpcPhich None
all set to ON when
DLSCH_PRI_TYPE the cell load is
0~11
_EPF, None heavy
None (for example, CellDlschAlgo None
DLSCH_PRI_TYPE the average cell
_PF, load exceeds
DLSCH_PRI_TYPE DLSCH_PRI_TYPE
InterRatMlbThd). CellDlschAlgo None
DLSCH_PRI_TYPE _EPF(EPF) _EPF(EPF)
_MAX_CI,
DLSCH_PRI_TYPE
0~100 0 0 CellDlschAlgo None
_RR

0~1, step:0.01 1 1 CellDlschAlgo None

0~1, step:0.01 10 10 CellDlschAlgo None


0~11 None None CellMLB None
In the CellMLB MO,
the sum of
IntraFreqMlbThd
1~100 60 60 CellMLB In the CellMLB MO,
and LoadOffset
the
must be of
sum less than
InterFreqMlbThd
100.
1~100 60 60 CellMLB 1. In the CellMLB
and
In theLoadOffset
CellMLB
MO, the sum ofMO,
LOAD_EXCHANGE must
the be of
sum less than
IntraFreqMlbThd
1~100 75 75 CellMLB 100.
InterRatMlbThd
_PERIOD_1S, and LoadOffset and
LOAD_EXCHANGE LoadOffset
must be lessmust
thanbe
_PERIOD_2S, In FDD mode, the
LOAD_EXCHANGE LOAD_EXCHANGE less
100. than 100.
CellMLB None
LOAD_EXCHANGE _PERIOD_5S(5s) recommended
_PERIOD_5S(5s) 2. In the CellMLB
_PERIOD_5S, value is 0 for MO, the sum of
LOAD_EXCHANGE
1~50 8 bandwidths
8 of 1.4 CellMLB InterFreqMlbThd
_PERIOD_10S MHz and 3 MHz, 10 and LoadOffset
for the bandwidth of must be less than
1~50 15 15
5
InMHz, and 20 for
non-ultra-high- CellMLB None
100.
bandwidths
speed scenarios, of 10 3. In the CellMLB
MHz,
for an 15 FDD MHz,
cell,and
the MO,
0~11 None None
20 MHz. CellPdcchAlgo Nonethe sum of
recommended InterRatMlbThd and
In TDDis mode,
value OFF if the
the LoadOffset must be
OFF, ON OFF(Off) recommended
cell bandwidth is
OFF(Off) CellPdcchAlgo less
Nonethan 100.
value
1.4 MHz is 0orfor
3 MHz,
bandwidths
and the of 1.4
1~4 3 3
MHz and 3 MHz, 5
recommended CellPdcchAlgo None
for
valuetheisbandwidth
ON for of
5 MHz,
other celland 10 for
OFF, ON ON(On) bandwidths CellPdcchAlgo None
bandwidths.of 10
MHz, 15 MHz, and
In non-ultra-high-
0~11 None 20
speedMHz.
None scenarios, CellPucchAlgo None
In the
It
theis recommended
recommended CellNoAccessAlmP
that
valuethe is default
OFF for a ara MO, if
0~50 10 value
TDD cell.of the CellPucchAlgo None
In the
NoAccessStartDete
parameter be
In ultra-high-speed CellNoAccessAlmP
ctTime is different
retained.
scenarios,If the CellNoAccessAlmP ara
from MO, if
0~11 None None
adjustments are None
NoAccessStartDete
recommended ara In the
NoAccessStopDete
mandatory,
value is OFFavoid for ctTime
ctTime,is different
CellNoAccessAlmP
setting
each this
cell. CellNoAccessAlmP from
ara MO, if
00:00:00~23:59:59 00:00:00 00:00:00 NoAccessDetectTi
parameter to an ara NoAccessStopDete
NoAccessStartDete
mer must be
excessively large ctTime,
ctTime
smalleristhan
different
the
CellNoAccessAlmP
00:00:00~23:59:59 00:00:00 value
00:00:00 as it may lead NoAccessDetectTi
from
time difference
ara
to incorrect mer must be
NoAccessStopDete
between
decisions
It on the
is recommended CellNoAccessAlmP smaller
ctTime, than the
NoAccessStartDete
0~72 0 0
load each
that status of SRI time difference
ara NoAccessDetectTi
ctTime and
resources. cell
neighboring between
mer must be less
NoAccessStopDete
0~11 None A value
uses
None less than
a unique band or CellUlIcic NoAccessStartDete
than
Nonethe time
ctTime.
equal to scheme.
division 20 is If ctTime andbetween
difference
MODE1(UL band recommended
this requirementif the NoAccessStopDete
NoAccessStartDete
MODE1, MODE2, cell bandwidth
division scheme cannot be met,islet CellUlIcic ctTime.
None and
ctTime
MODE3 below 10 MHz. A
No.1) the neighboring NoAccessStopDete
value lesshave
cells that than or ctTime.
0~11 None None to 40
equal
weakest is
mutual CellSimuLoad None
recommended
interference useif the
0~9 4 another
same
4 bandcell division CellSimuLoad None
bandwidth is used.
scheme.
TM1, TM2, TM7,
TM2(TM2) TM2(TM2) CellSimuLoad None
TM8

0~100 None None CellSimuLoad None


0~100 None None CellSimuLoad None

0~100, step:0.01 None None CellSimuLoad None

0~100, step:0.01 None None CellSimuLoad None

0~1200 None None CellSimuLoad None

0~1200 None None CellSimuLoad None

MOD_PERIOD_CO
0~11
EFF_N2, None None BcchCfg None
MOD_PERIOD_CO
EFF_N4, MOD_PERIOD_CO MOD_PERIOD_CO
BcchCfg None
MOD_PERIOD_CO EFF_N4(4) EFF_N4(4)
EFF_N8,
MOD_PERIOD_CO
0~11 None Nonein normal
-600 CellChPwrCfg None
EFF_N16 scenarios and peak
-15.875~15.875, rate tests, or 0 in
-600 -600 in normal CellChPwrCfg None
step:0.005 the tests on the
scenarios
maximum and cell peak
-15.875~15.875, rate tests,
radius. or 0 in
-600 CellChPwrCfg None
step:0.005 the tests on the
maximum cell
-15.875~15.875, radius.
0 0
-600 in normal CellChPwrCfg None
step:0.005
scenarios and peak
-15.875~15.875, rate tests, or 0 in
-600 CellChPwrCfg None
step:0.005 the tests on the
maximum cell
-15.875~15.875, radius.
0 0 CellChPwrCfg None
step:0.005
-15.875~15.875,
0 0 CellChPwrCfg None
step:0.005
-15.875~15.875,
0 0 CellChPwrCfg None
step:0.005

0~11 None None PDSCHCfg None

-60~50, step:0.1 182 None PDSCHCfg None

Single-antenna: 0;
0~3 1 PDSCHCfg None
double-antenna: 1
DBM_120,
DB0_PWR_RAMPI
DBM_118,
0~11
NG_STEP, None None RACHCfg None
DBM_116,
DB2_PWR_RAMPI
DBM_114,
NG_STEP, DB2_PWR_RAMPI DB2_PWR_RAMPI
DBM_112, RACHCfg None
DB4_PWR_RAMPI NG_STEP(2dB) NG_STEP(2dB)
DBM_110,
NG_STEP,
DBM_108,
DB6_PWR_RAMPI DBM_104(- DBM_104(-
RACHCfg None
DBM_106,
NG_STEP 104dBm) 104dBm)
DBM_104,
DBM_102,
0~11 None None SRSCfg None
SC0, SC1, SC2,
DBM_100,
SC3, SC4,DBM_96,
DBM_98, SC5,
SC6, SC7,DBM_92,
DBM_94, SC8, SC3(3) SC3(3) SRSCfg None
SC9, SC10, SC11,
DBM_90
SC12, SC13, SC14
follows: 0, 0, 7, 12,
17, 20, in
ascending order of
channel bandwidth;
In TDD mode, if
SubframeAssignme
nt is set to SA1, the
BOOLEAN_FALSE, BOOLEAN_TRUE( normal CP is used,
BOOLEAN_TRUE(
and DeltaShift is set SRSCfg None
BOOLEAN_TRUE True) True)
If
toUlHoppingType
and HoppingMode
DS2_DELTA_SHIFT
0~11 None None
are PHICHCfg None
, theset to
recommended
HOPPING_TYPE2
values of this
NORMAL, and
parameter
NORMAL NORMAL are as PHICHCfg None
EXTENDED INTER_SUB_FRA
follows: 0, 0, 6, 11,
ME,
15, 17,respectively,
in
ONE_SIXTH, HALF, the
ONE ONErecommended
ascending order of PHICHCfg None
ONE, TWO value of this
channel bandwidth;
parameter
In TDD mode, is 4.if
0~11 None None
If UlHoppingType PCCHCfg None
SubframeAssignme
and
nt is HoppingMode
set to SA1, the
FOURT,
rf32, rf64,TWOT,
rf128, rf128(128 radio rf128(128
are to radio
set CP
ONET, normal is used, PCCHCfg None
rf256 HALFT, frames) frames)
HOPPING_TYPE2
and DeltaShift is set
QUARTERT, and
ONE_EIGHTT, to
ONET INTRA_AND_INTE
ONET
DS3_DELTA_SHIFT PCCHCfg None
ONE_SIXTEENTHT R_SUB_FRAME,
, , the recommended
respectively,
values of thisthe
ONE_THIRTY_SEC
0~11 None None
recommended PUSCHCfg None
ONDT parameter are as
value
follows: of 0,
this0, 8, 15,
parameter
21, 24, in is 1.
1~4 4 PUSCHCfg None
If UlHoppingType
ascending order of
INTER_SUB_FRA and HoppingMode
ME, INTER_SUB_FRA channel bandwidth;
INTER_SUB_FRA
are
In TDDset to
mode, if PUSCHCfg None
INTRA_AND_INTE ME(Inter) ME(Inter)
HOPPING_TYPE2_ The value of this
R_SUB_FRAME SubframeAssignme
RANDOM parameter must be
nt is set to andSA1, the
0~98 22 INTER_SUB_FRA PUSCHCfg smaller than or
extended CP is
ME, equal to the cell
used,respectively,
and
BOOLEAN_FALSE, BOOLEAN_FALSE( the recommended
BOOLEAN_FALSE( bandwidth.
DeltaShift is set to PUSCHCfg None
BOOLEAN_TRUE False) value
False) of this
DS3_DELTA_SHIFT
parameter is 4.
, the recommended
0~29 0 If
0 UlHoppingType
values of this PUSCHCfg None
and HoppingMode
parameter are as
BOOLEAN_FALSE, BOOLEAN_FALSE( are
follows:to
set 0, 0, 8, 15,
BOOLEAN_FALSE(
HOPPING_TYPE2_ PUSCHCfg None
BOOLEAN_TRUE False) 22, 26, in
False)
RANDOM
ascending and order of
INTRA_AND_INTE
channel bandwidth;
0~7 0 0
No recommended
R_SUB_FRAME, PUSCHCfg None
In TDDThe
value. mode,valueif
respectively,
SubframeAssignme the
BOOLEAN_FALSE, BOOLEAN_TRUE( should be set
recommended
nt is setontothe
SA2, the PUSCHCfg None
BOOLEAN_TRUE True) based
value ofCP
thisis used,
normal
64QAM capability
parameter
and is 4.is set
DeltaShift
0~11 None of
Nonethe UE. PUCCHCfg None
to
DS2_DELTA_SHIFT DS2_DELTA_SHIFT
, DS2_DELTA_SHIF DS2_DELTA_SHIF
, the recommended PUCCHCfg None
DS3_DELTA_SHIF T(ds2) T(ds2)
values of this
T CellGlobalId in the
parameter are as Cdma2000External Cdma2000External
6~16 characters None None 0, 0, 9, 15,
follows: CellPlmn CellPlmn
ShareMccMO must
in the
21, 25, in be numeric.
ascending order of Cdma2000External
Cdma2000External
000~999 None None
channel bandwidth; CellPlmn MO
CellPlmn ShareMnc
In TDD mode, if consists of in the
digits
Cdma2000External
only.
SubframeAssignme Cdma2000External
00~99,000~999 None None CellPlmn MO
nt is set to SA2, the CellPlmn
consists of digits
normal CP is used, only.
Cdma2000HrpdNce
0~11 None NoneDeltaShift is set
and None
ll
to CellGlobalId in the
DS3_DELTA_SHIFT Cdma2000HrpdNce Cdma2000HrpdNce
6~16 characters None None
, the recommended ll ll MO consists of 16
values of this decimal digits.
parameter are as
follows: 0, 0, 10, 16,
22, 26, in
ascending order of
channel bandwidth;
In TDD mode, if
PERMIT_HO_ENU In the
M, PERMIT_HO_ENU PERMIT_HO_ENU Cdma2000HrpdNce Cdma2000HrpdNce
None
FORBID_HO_ENU M(Permit Ho) M(Permit Ho) ll ll MO, the value of
PERMIT_RMV_EN
M The
In the
LocalCellName is a
UM, PERMIT_RMV_EN PERMIT_RMV_EN Cdma2000HrpdNce Cdma2000HrpdNce
None of a
string
FORBID_RMV_EN UM(Permit Rmv) UM(Permit Rmv) ll MOs the
llmaximum
MO, associated
value
of 99 of
UM with the same
Cdma2000HrpdNce
NeighbourCellNam
characters. Thelocal
0~32 0 0 cell
e must each
string cannotofbe
is a string ahave
all
ll
a unique
maximum value
null characters orof 99 of
BlindHoPriority
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Cdma2000HrpdNce characters.
contain any Theof theif
None
the
stringvalue
cannot is non-
be all
BOOLEAN_TRUE False) False) ll following
zero.
null characters
characters: double or
Cdma2000HrpdNce contain any of the
0~99 characters NULL None quotation marks ("),
ll following
commas (,),
characters: double
Cdma2000HrpdNce semicolons
A maximum (;),
of 16
0~99 characters NULL None quotation
equal signs marks
(=), ("),
ll Cdma2000Nfreq
commas
single (,),
quotation
MOs with
semicolons the same
(;),
0~11 None None Cdma2000Nfreq marks
A maximum
combination('), threeof
of 16
bc0, bc1, bc2, bc3, equal signs (=),
consecutive
Cdma2000Nfreq
LocalCellId plus
and
bc4, bc5, bc6, bc7, single quotation
signs
MOs
BandClass(+++),
with the two
can samebeor
bc8, bc9, bc10, marks ('), three
None None Cdma2000Nfreq more consecutive
combination
configured. of
bc11, bc12, bc13, consecutive plusor
blanks, and and
LocalCellId two
bc14, bc15, bc16, signs (+++), twobe or
more consecutive
BandClass can
bc17
0~2047 None None Cdma2000Nfreq more
None consecutive
percentage signs
configured.
blanks,
(%). and two or
more consecutive
-15~15 0 0 Cdma2000Nfreq None
percentage signs
(%).
NOT_CFG(Not NOT_CFG(Not 1.
NOT_CFG, CFG
configure) configure)
Cdma2000Nfreq If Mcc in the
None
EutranExternalCell
SearchWindowSize
Plmn
CfgInd MO is consists
set
0~15 None None Cdma2000Nfreq 1.
of Mnc
digits the to
inonly.
CFG,
EutranExternalCell
2. In the
SearchWindowSize
EutranExternalCell Plmn
must
MO consists
EutranExternalCell
be only.
set.
000~999 None None of digits
Plmn Plmn MO, the
2. In the
combination of Mnc
EutranExternalCell EutranExternalCell
and Mcc must be
00~99,000~999 None None
Plmn Plmn
differentMO, fromthe that of
combination of Mnc
EutranExternalCell ShareMnc
and
and
0~1048575 None None
Plmn ShareMcc. inbe
1.
None Mcc
ShareMcc must the
different from that of
EutranExternalCell
ShareMnc
EutranExternalCell Plmn and
MO consists
0~255 None None 1.
NoneShareMnc
ShareMcc.
of digits only. in the
Plmn EutranExternalCell
2. In the
EutranExternalCell Plmn MO consists
EutranExternalCell
000~999 None None of digits only.
Plmn Plmn MO, the
2. In the
combination of Mnc
EutranExternalCell EutranExternalCell
and Mcc must be
00~99,000~999 None None
Plmn Plmn
differentMO, fromthe that of
combination of Mnc
GeranExternalCellP ShareMnc
and
1. MccMcc
and
in must
the be
0~65535 None None None
ShareMcc.
lmn different from that of
GeranExternalCellP
ShareMnc
GeranExternalCellP lmn MO consists and of
1~65533,65535 None None 1.
NoneMnconly.
ShareMcc.
digits in the
lmn GeranExternalCellP
2. In the
GeranExternalCellP lmn
1.
MO consists of
GeranExternalCellP
ShareMcc in the
000~999 None None digits only.
lmn lmn MO, the
GeranExternalCellP
2. In the
combination of Mnc
GeranExternalCellP lmn
and
MO consists
GeranExternalCellP
Mcc must be
of
00~99,000~999 None None digits only.
lmn lmn MO, the
different
2. In the fromofthat
combination Mnc
of
ShareMnc
GeranExternalCellP GeranExternalCellPand
000~999 None None and Mcc must be
ShareMcc.
lmn lmn MO, from
different the that of
combination
ShareMnc and of Mnc
and Mcc
ShareMcc. must be
different from that of
ShareMnc and
ShareMcc.
1. ShareMnc in the
GeranExternalCellP
lmn MO consists of
digits only.
2. In the
GeranExternalCellP GeranExternalCellP
1. Mcc in the
00~99,000~999 None None
lmn lmn MO, the
UtranExternalCellPl
combination
mn MO consists of Mnc of
UtranExternalCellPl and
1. MncMcc in must
the be
0~268435455 None None None
digits only.
mn different
2. In the from that of
UtranExternalCellPl
UtranExternalCellPl ShareMnc
mn MO consistsand of
UtranExternalCellPl
000~999 None None 1. ShareMcc
ShareMcc.
digits only. in the
mn mn MO, the
UtranExternalCellPl
2. In the
combination of Mnc
1. InMO
mn theconsists of
UtranExternalCellPl UtranExternalCellPl
and
1. Mcc
ShareMnc must inbethe
00~99,000~999 None None Cdma2000External
digits only.
mn mn MO, the
different
2. the fromofthat
UtranExternalCellPl
CellIn MO,
combination Mnc
of
UtranExternalCellPl ShareMnc
mn MO
CellGlobalId and
consists
UtranExternalCellPl of
000~999 None None and Mcc
ShareMcc.
digits only.must be
mn consists
mn MO, of 16
the
different
2. In the from that of
decimal digitsofifMnc
combination
UtranExternalCellPl ShareMnc and
UtranExternalCellPl
00~99,000~999 None None Cdma2000Type
and Mcc must beis
mn ShareMcc.
mn MO, the
set to
different from that of
combination
CDMA2000_HRPD.
ShareMnc and of Mnc
Cdma2000External and Mcc must be
6~16 characters
bc0, bc1, bc2, bc3, None None 2. In the
ShareMcc.
Cell different from that of
bc4, bc5, bc6, bc7, Cdma2000External
bc8, bc9, bc10, Cdma2000External ShareMnc
Cell MO, and
None None None
ShareMcc.
CellGlobalId
bc11, bc12, bc13, Cell
bc14, bc15, bc16, consists of 6
Cdma2000External decimal
bc17
0~2047 None None None digits if
Cell Cdma2000Type is
In
setthe
to
Cdma2000External Cdma2000External
0~511 None None CDMA2000_1XRTT
None
Cell Cell MO, the value
.
of CellName is a
CDMA2000_HRPD, CDMA2000_HRPD( CDMA2000_HRPD( Cdma2000External
None of a
string
CDMA2000_1XRTT CDMA2000_HRPD) CDMA2000_HRPD) Cell
maximum
Mcc in the of 99
Cdma2000External characters.
Cdma2000External The
000~999 None None string cannot be all
Cell Cell MO consists of
Mnc
null inonly.
the
digitscharacters or
Cdma2000External Cdma2000External
contain any of the
00~99,000~999 None None
Cell Cell MO consists of
following
digits only. double
characters:
Cdma2000External
0~99 characters NULL None quotation marks ("),
Cell
commas (,),
Cdma20001XRTTN semicolons (;),
0~11 None None None
equal signs (=),
cell
CellGlobalId
single quotation in the
Cdma20001XRTTN Cdma20001XRTTN
marks ('), three
6~16 characters None None
cell cell MO consists
consecutive plus of
PERMIT_HO_ENU In
6 the (+++), two or
digits.
signs
M, PERMIT_HO_ENU PERMIT_HO_ENU Cdma20001XRTTN Cdma20001XRTTN
more
None consecutive
FORBID_HO_ENU M(Permit Ho) M(Permit Ho) cell cell
In MO,and
the the two
value
PERMIT_RMV_EN blanks,
The or
M of LocalCellName
Cdma20001XRTTN is
UM, PERMIT_RMV_EN PERMIT_RMV_EN Cdma20001XRTTN more consecutive
Cdma2000HrpdNce
None
a string
cell MO,ofthe
percentage a signs
value
FORBID_RMV_EN UM(Permit Rmv) UM(Permit Rmv) cell llmaximum
MOs associated
of
(%). of 99
UM with the same
Cdma20001XRTTN characters.
NeighbourCellNam Thelocal
0~32 0 0 cell
stringmust each
cannotofbe have
cell e is a string a all
a unique value
null characters of
maximum of 99or
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( Cdma20001XRTTN BlindHoPriority
contain any The
of theif
characters.
None
BOOLEAN_TRUE False) False) cell the value is non-
following
string cannot be all
zero.
characters: double
Cdma20001XRTTN null characters or
0~99 characters NULL None quotation marks
contain any of the ("),
cell
commas (,),
following
Cdma20001XRTTN semicolons double
characters: (;),
0~99 characters NULL None equal signs (=), ("),
cell quotation marks
single quotation
commas (,),
Cdma2000BandCla marks
0~11 None None None ('), three
semicolons (;),
ss consecutive
equal signs (=),plus
signs (+++),
single quotationtwo or
more
marksconsecutive
('), three
blanks,
consecutive and twoplusor
more consecutive
signs (+++), two or
percentage
more signs
consecutive
(%).
blanks, and two or
more consecutive
bc0, bc1, bc2, bc3,
bc4, bc5, bc6, bc7,
bc8, bc9, bc10, Cdma2000BandCla
None None None
bc11, bc12, bc13, ss
bc14, bc15, bc16,
bc17 Cdma2000BandCla In the
0~7 1 1 None
ss Cdma2000BandCla
ss MO,
Cdma2000BandCla In the
0~63 22 22 ThreshXHigh must
ss Cdma2000BandCla
be less than or
ss MO,
Cdma2000BandCla equal to
0~63 22 22 ThreshXHigh
ThreshXLow. must
ss
be
Mccless than or
in the
equal to
GeranExternalCell
000~999 None None GeranExternalCell ThreshXLow.
MO consists of
Mnc
digitsinonly.
the
GeranExternalCell
00~99,000~999 None None GeranExternalCell
MO consists of
digits only.
0~65535 None None GeranExternalCell None

1~65533,65535 None None GeranExternalCell If RacCfgInd is set


None
to CFG, Rac must
be set.
NOT_CFG(Not NOT_CFG(Not
NOT_CFG, CFG GeranExternalCell If RacCfgInd is set
configure) configure)
to NOT_CFG, Rac
does not need to be
0~255 None None GeranExternalCell None
set.

GSM_dcs1800,
None None GeranExternalCell None
GSM_pcs1900
In the
0~1023 None None GeranExternalCell None
GeranExternalCell
MO, the value of
CellName is a string
0~7 None None GeranExternalCell None
of a maximum of 99
characters. The
0~7 None None GeranExternalCell string
None cannot be all
null characters or
DTM_AVAILABLE, contain any of the
DTM_NOT_AVAILA DTM_NOT_AVAILA
DTM_NOT_AVAILA GeranExternalCell None
following
BLE BLE
BLE characters: double
quotation marks ("),
0~99 characters NULL None GeranExternalCell
commas (,),
semicolons (;),
0~11 None None GeranNcell equal
None signs (=),
single
Mcc inquotation
the
marks ('), three
GeranNcell MO
000~999 None None GeranNcell consecutive plus
consists of digits
signs
Mnc
only. (+++),
in the two or
more consecutive
GeranNcell MO
00~99,000~999 None None GeranNcell
blanks, and
consists two or
of digits
more consecutive
only.
1~65533,65535 None None GeranNcell percentage
None signs
(%).

0~65535 None None GeranNcell None


PERMIT_RMV_EN
UM, PERMIT_RMV_EN PERMIT_RMV_EN
GeranNcell None
FORBID_RMV_EN UM(Permit Rmv) UM(Permit Rmv)
PERMIT_HO_ENU
UM
M, PERMIT_HO_ENU
None GeranNcell None
FORBID_HO_ENU M(Permit Ho)
M
In the GeranNcell
MO, the value of
LocalCellName is a
In the of
string GeranNcell
a
In
MO,all GeranNcell
maximumvalue
the of 99of
MOs
characters. Thecell,
of a
NeighbourCellNam local
BlindHoPriority
e is a string
string cannotofbe a all
0~32 0 0 GeranNcell
must
maximum have
null characters or a
of unique
99
value if itany
characters.
contain is The
non-
of the
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( zero.
string cannot be all
GeranNcell None
following
BOOLEAN_TRUE False) False) null characters or
characters: double
contain any
quotation marks ("),of the
0~99 characters NULL None GeranNcell following
commas (,),
characters:
semicolons double (;),
quotation
equal signs marks
(=), ("),
0~99 characters NULL None GeranNcell
commas (,),
single quotation
semicolons
marks ('), three (;),
0~11 None None GeranNfreqGroup equal
consecutive (=),
None signs plus
single quotation
signs (+++), two or
marks ('), three
more consecutive
0~31 None None GeranNfreqGroup None
consecutive plusor
blanks, and two
signs (+++),
more consecutive two or
GSM, GPRS, more consecutive
percentage signs
None None GeranNfreqGroup None
EDGE blanks,
(%). and two or
more consecutive
0~1023 None None GeranNfreqGroup percentage
None signs
(%).
GSM_dcs1800,
None None GeranNfreqGroup None
GSM_pcs1900
NOT_CFG(Not NOT_CFG(Not
NOT_CFG, CFG GeranNfreqGroup None
configure) configure) If
If
CellReselPriorityCfg
PmaxGeranCfgInd
0~7 1 1 GeranNfreqGroup Ind is to
is set setCFG,
to CFG,
If
CellReselPriority
PmaxGeran must
NOT_CFG(Not NOT_CFG(Not PmaxGeranCfgInd
must
be be set.
set.
NOT_CFG, CFG GeranNfreqGroup is
configure) configure) If set to CFG,
PmaxGeran
PmaxGeranCfgInd must
be set.
is set to NOT_CFG,
0~39 None None GeranNfreqGroup
If
PmaxGeran does
PmaxGeranCfgInd
not need to be set.
-115~-25, step:2 5 5 GeranNfreqGroup is set
the to NOT_CFG,
None
In
PmaxGeran
GeranNfreqGroup does
not need to
MO, ThreshXHighbe set.
0~62, step:2 7 7 GeranNfreqGroup In the
must be less than
GeranNfreqGroup
or equal to
MO, ThreshXHigh
ThreshXLow.
0~62, step:2 7 7 GeranNfreqGroup
must be less than
or equal to
-15~15 0 0 GeranNfreqGroup ThreshXLow.
None

0~255 255 255 GeranNfreqGroup None

GeranNfreqGroupA
0~11 None None None
rfcn
GeranNfreqGroupA
0~31 None None None
rfcn
GeranNfreqGroupA
0~1023 None None None
rfcn

0~11 None None IntraFreqBlkCell Nonevalue of this


The
parameter must be
different from the
0~503 None None IntraFreqBlkCell
physical cell
identifier of the
serving cell.
EutranIntraFreqNC
0~11 None None None
ell
Mcc in the
EutranIntraFreqNC EutranIntraFreqNC
000~999 None None
ell ell MO consists of
Mnc
digitsinonly.
the
EutranIntraFreqNC EutranIntraFreqNC
00~99,000~999 None None
ell ell MO consists of
digits only.
EutranIntraFreqNC The smaller the
0~1048575
dB-24, dB-22, dB- None None None
value of this
ell
20, dB-18, dB-16, parameter, the less
dB-14, dB-12, dB- EutranIntraFreqNC probable that the
0~255
dB-24, dB-22, None None None
10, dB-8, dB-6,dB-
dB- ell UE camps on the
20, dB-18,
5, dB-4, dB-16,
dB-3, dB-2, neighboring cell
dB-14, dB-12, dB- dB0(0dB) EutranIntraFreqNC
dB-1, dB0, dB1, dB0(0dB) during reselection.
10, ell
dB2,dB-8,
dB3,dB-6,
dB4, dB- The
In the larger the value
5, dB-4,
dB5, dB6,dB-3,
dB8,dB-2, of this parameter,
EutranIntraFreqNC EutranIntraFreqNC
dB-1,
dB10, dB0,
dB12, dB14, dB0(0dB)
dB1, dB0(0dB)
ell
None
the more
ell MO, the probable
value of
dB2,
dB16,dB3, dB4,
PERMIT_HO_ENU
dB18, dB20, that
In thethe UE camps
dB5, LocalCellName is a
dB22,dB6,
M, dB24 dB8, PERMIT_HO_ENU PERMIT_HO_ENU EutranIntraFreqNC EutranIntraFreqNC
on
None the
string neighboring
of a
dB10, dB12, dB14, M(Permit Ho)
FORBID_HO_ENU M(Permit Ho) ell cell.
ell MO, theofvalue
PERMIT_RMV_EN
dB16, dB18, dB20, maximum 99 of
M NeighbourCellNam
UM,
dB22, dB24 PERMIT_RMV_EN PERMIT_RMV_EN EutranIntraFreqNC characters. The
None
e is a string
string cannotofbe a all
FORBID_RMV_EN UM(Permit Rmv) UM(Permit Rmv) ell
maximum of
null characters or 99
UM
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( EutranIntraFreqNC characters.
contain any Theof the
None
string cannot be all
BOOLEAN_TRUE False) False) ell following
null characters
characters: doubleor
EutranIntraFreqNC contain any of the
0~99 characters NULL None quotation marks ("),
ell following
commas (,),
characters: double
EutranIntraFreqNC semicolons (;),
0~99 characters NULL None quotation
equal signs marks
(=), ("),
ell
commas (,),
single quotation
semicolons
marks (;),
('), three
0~11 None None EutranInterNFreq None
equal
consecutive (=),
signs plus
DlEarfcn
single in the
quotation
signs
1. (+++),
The ('),
DL three two or
0~39649,65336~65 EutranInterNFreq
marks
None None EutranInterNFreq more
frequencyconsecutive
and UL
535 MO must be
consecutive a valid
plus
blanks,
frequency andmusttwo or
be
frequency.
signs (+++), two or
NOT_CFG(Not NOT_CFG(Not more
in consecutive
the consecutive
same
NOT_CFG, CFG EutranInterNFreq more
None
percentage signs
configure) configure) frequency
blanks,
(%). andband.
two or
If UlEarfcnCfgInd
more consecutive is
18000~39649,6533
None None EutranInterNFreq set to CFG, signs
percentage
6~65535
UlEarfcn
(%). must be
NOT_CFG(Not NOT_CFG(Not set.
NOT_CFG, CFG EutranInterNFreq None
2.
configure) configure) If UlEarfcn in the
EutranInterNFreq
CellReselPriorityCfg
0~7 1 1 EutranInterNFreq MO
Ind ismust
set tobeCFG,a valid
frequency.
CellReselPriority
must be set.
0~7 1 1 EutranInterNFreq None

NOT_CFG(Not NOT_CFG(Not
NOT_CFG, CFG EutranInterNFreq None
configure) configure) If
0DOT25_ENUM,
SpeedDependSPCf
0DOT5_ENUM,
None None EutranInterNFreq gInd is set to CFG,
0DOT75_ENUM, If
0DOT25_ENUM, TReselEutranSfMe
1DOT0_ENUM SpeedDependSPCf
0DOT5_ENUM, dium must be set.
None None EutranInterNFreq gInd is set to CFG,
0DOT75_ENUM,
TReselEutranSfHig
1DOT0_ENUM
MBW6, MBW15, h must be set.
MBW25, MBW50, None None EutranInterNFreq None
MBW75, MBW100
dB-24, dB-22, dB-
20, dB-18, dB-16,
dB-14, dB-12, dB- A larger value of
10, dB-8, dB-6, dB- this parameter
5, dB-4, dB-3, dB-2, leads to a lower
A larger value of
dB-1, dB0, dB1, dB1(1dB) dB1(1dB) EutranInterNFreq probability
In of
thistheparameter
dB2, dB3, dB4, reselection to a
EutranInterNFreq
leads to a lower
dB5, dB6, dB8, neighboring
MO, cell on
ThreshXhigh
0~62, probability of a cell
dB10, step:2
dB12, dB14, 0 0 EutranInterNFreq In
thethe
must frequency.
be less than
meeting criteria
EutranInterNFreq S
dB16, dB18, dB20, or equal to
and
MO, becoming
ThreshXhigh a
dB22, dB24
0~62, step:2 0 0 EutranInterNFreq ThreshXlow.
suitable
must be cell lessfor
than
selection.
or equal toA smaller
value of this
ThreshXlow.
-140~-44, step:2 -64 -64 EutranInterNFreq
parameter leads to
a higher probability.
NOT_CFG(Not NOT_CFG(Not Set this parameter
NOT_CFG, CFG If the frequency on EutranInterNFreq None
configure) configure) properly so that the
which the inter-
If PmaxCfgInd
selected is
cell can
frequency
-30~33 0 0 EutranInterNFreq set to CFG,
provide Pmax
signals that
neighboring cell
BitString00, must
meet be theset.
quality
operates is located
BitString01, in the same requirement of
BitString01(01) BitString01(01) EutranInterNFreq None
BitString10, frequency band as basic services.
BitString11
BOOLEAN_FALSE, BOOLEAN_FALSE( the serving
BOOLEAN_FALSE(
frequency, the EutranInterNFreq None
BOOLEAN_TRUE False) False)
recommended
value is EventA3.
EventA3, EventA4 EventA4(EventA4) EutranInterNFreq None
If the frequency on
which the inter-
0~11 None frequency
None InterFreqBlkCell None
neighboring cell DlEarfcn in the
0~39649,65336~65 operates is located InterFreqBlkCell
None None
in a different InterFreqBlkCell
535 MO must be a valid
frequency band frequency.
from the serving
0~503 None None InterFreqBlkCell None
frequency, the
recommended
value EutranInterFreqNC
0~11 None None is EventA4. None
ell
Mcc in the
EutranInterFreqNC EutranInterFreqNC
000~999 None None
ell ell MO consists of
Mnc
digitsinonly.
the
EutranInterFreqNC EutranInterFreqNC
00~99,000~999 None None
ell ell MO consists of
digits only.
EutranInterFreqNC The smaller the
0~1048575
dB-24, dB-22, dB- None None None
value of this
ell
20, dB-18, dB-16, parameter, the less
dB-14, dB-12, dB- EutranInterFreqNC probable that the
0~255
dB-24, dB-22, None None None
10, dB-8, dB-6,dB-
dB- ell UE camps on the
20, dB-18,
5, dB-4, dB-16,
dB-3, dB-2, neighboring cell
dB-14, dB-12, dB- dB0(0dB) EutranInterFreqNC
dB-1, dB0, dB1, dB0(0dB) during reselection.
10, ell
dB2,dB-8,
dB3,dB-6,
dB4, dB- The larger the value
5, dB-4,
dB5, dB6,dB-3,
dB8,dB-2, EutranInterFreqNC of this parameter,
dB-1,
dB10, dB0,
dB12, dB1,
dB14, dB0(0dB) dB0(0dB) None
the more probable
ell
dB2, dB3, dB4,
PERMIT_HO_ENU
dB16, dB18, dB20, that the UE camps
dB5,
dB22,dB6,
M, dB24 dB8, PERMIT_HO_ENU PERMIT_HO_ENU EutranInterFreqNC on the neighboring
dB10, dB12, dB14, M(Permit Ho) None
FORBID_HO_ENU M(Permit Ho) ell cell.
PERMIT_RMV_EN
dB16,
M dB18, dB20,
UM,
dB22, dB24 PERMIT_RMV_EN PERMIT_RMV_EN EutranInterFreqNC In all
None
FORBID_RMV_EN UM(Permit Rmv) UM(Permit Rmv) ell EutranInterFreqNC
UM ell MOs of a local
EutranInterFreqNC
0~32 0 0 cell, BlindHoPriority
ell
must have a unique
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( EutranInterFreqNC value if it is non-
None
zero.
BOOLEAN_TRUE False) False) ell
string of a
ell MO, theofvalue
maximum 99 of
NeighbourCellNam
characters. The
e is a string
string cannotofbe a all
maximum
null characters or of 99
characters.
contain any The of the
string
following cannot be all
null characters
characters: doubleor
EutranInterFreqNC contain any of the
0~99 characters NULL None quotation marks ("),
ell following
commas (,),
characters: double
EutranInterFreqNC semicolons (;),
0~99 characters NULL None quotation
equal signs marks
(=), ("),
ell
commas
Mcc
single (,),
inquotation
the
semicolons
EutranExternalCell (;),
000~999 None None EutranExternalCell marks
equal
('), three
MO consists(=),
signs
consecutive of
plus
Mnc
single
digits inquotation
the
signs only.
(+++), two or
EutranExternalCell
00~99,000~999 None None EutranExternalCell marks ('), three
more consecutive
MO consists plus
consecutive of
blanks, and two or
digits
signs only.
more consecutiveor
(+++), two
0~1048575 None None EutranExternalCell more
None consecutive
percentage signs
blanks,
(%). and two or
more consecutive
0~255 None None EutranExternalCell percentage
None signs
DlEarfcn
(%). in the
0~39649,65336~65 EutranExternalCell
None None EutranExternalCell
535 MO must be a valid
frequency.
1. the
In If UlEarfcnCfgInd
NOT_CFG(Not NOT_CFG(Not
NOT_CFG, CFG EutranExternalCell None
is set to CFG,
EutranExternalCell
configure) configure)
UlEarfcn
MO, must of
the value be
18000~39649,6533 set.
CellName is a string
None None EutranExternalCell
6~65535 2. a
of UlEarfcn
maximum in the
of 99
EutranExternalCell
characters. The
0~503 None None MO
EutranExternalCell string
None must
cannot be abe valid
all
EARFCN.
null characters or
contain any of the
0~65535 None None EutranExternalCell None
following
characters: double
quotation marks ("),
0~99 characters NULL None EutranExternalCell
commas (,),
semicolons (;),
0~11 None None UtranNCell equal
None signs (=),
single
Mcc inquotation
the
marks
UtranNCell ('), threeMO
000~999 None None UtranNCell consecutive plus
consists of digits
signs
Mnc
only. in(+++),
the two or
more consecutive
UtranNCell MO
00~99,000~999 None None UtranNCell
blanks,
consistsand two or
of digits
more consecutive
only.
0~268435455 None None UtranNCell percentage
None signs
PERMIT_HO_ENU (%).
M, PERMIT_HO_ENU PERMIT_HO_ENU In the UtranNCell
UtranNCell None
MO, the value of
FORBID_HO_ENU M(Permit Ho) M(Permit Ho)
PERMIT_RMV_EN
M LocalCellName is a
UM, PERMIT_RMV_EN PERMIT_RMV_EN In the of
string UtranNCell
a
UtranNCell None
In
MO, all UtranNCell
FORBID_RMV_EN UM(Permit Rmv) UM(Permit Rmv) maximumvalue
the of 99of
UM MOs
characters. Thecell,
of a
NeighbourCellNam local
BlindHoPriority
e is a string
string cannotofbe a all
0~32 0 0 UtranNCell
must
maximum haveof
null characters a 99unique
or
value if itany
characters.
contain is The
non-
of the
BOOLEAN_FALSE, BOOLEAN_FALSE( BOOLEAN_FALSE( zero.
string
UtranNCell None cannot be all
following
BOOLEAN_TRUE False) False) null characters or
characters: double
contain any
quotation marks ("), of the
0~99 characters NULL None UtranNCell following
commas (,),
characters:
semicolons double (;),
quotation
equal signs marks
(=), ("),
0~99 characters NULL None UtranNCell
commas
single quotation(,),
semicolons
marks ('), three (;),
0~11 None None UtranNFreq equal
None signs (=),
consecutive plus
single quotation
signs (+++), two or
marks ('), three
more consecutive
consecutive
blanks, and two plusor
signs (+++),
more consecutive two or
more consecutive
percentage signs
blanks,
(%). and two or
more consecutive
percentage signs
0~16383 None None UtranNFreq None

R99, HSDPA,
HSUPA HSUPA UtranNFreq None
HSUPA, HSPA
UTRAN_FDD,
UTRAN_FDD UTRAN_FDD UtranNFreq None
UTRAN_TDD 1. If
NOT_CFG(Not NOT_CFG(Not UtranUlArfcnCfgInd
NOT_CFG, CFG UtranNFreq None
is set to CFG,
configure) configure)
UtranUlArfcn must
be set.
0~16383 None None UtranNFreq
2. The DL UARFCN
and UL UARFCN
NOT_CFG(Not NOT_CFG(Not must
NOT_CFG, CFG UtranNFreq None be in the
configure) configure) If
same frequency
CellReselPriorityCfg
band.
0~7 1 1 UtranNFreq Ind is set to CFG,
CellReselPriority
must be set.
-50~33 33 33 UtranNFreq None

-15~15 0 0 UtranNFreq None

-24~0 -22 -22 UtranNFreq None

-119~-25, step:2 -50 -50 UtranNFreq None


In the UtranNFreq
MO, ThreshXHigh
0~62, step:2 0 0 UtranNFreq must be less than
In
or the
equalUtranNFreq
to
MO, ThreshXHigh
ThreshXLow.
0~62, step:2 0 0 UtranNFreq must be less than
or equal
Mcc in theto
ThreshXLow.
UtranExternalCell
000~999 None None UtranExternalCell
MO consists of
Mnc
digitsinonly.
the
UtranExternalCell
00~99,000~999 None None UtranExternalCell
MO consists of
digits only.
0~268435455 None None UtranExternalCell In the
None
UtranExternalCell
MO, PScrambCode
UTRAN_FDD, In all exceed 127
UTRAN_FDD None UtranExternalCell cannot
UTRAN_TDD UtranExternalCell
if UtranFddTddType
MOs
is set of
to a local cell,
0~16383 None None UtranExternalCell the combination of
UTRAN_TDD.
UtranDlArfcn and
NOT_CFG(Not NOT_CFG(Not PScrambCode must
NOT_CFG, CFG UtranExternalCell None
be
configure) configure) If unique.
UtranUlArfcnCfgInd
0~16383 None None UtranExternalCell is set to CFG,
UtranUlArfcn must
be set.
0~4095 None None UtranExternalCell None

NOT_CFG(Not NOT_CFG(Not
NOT_CFG, CFG UtranExternalCell None
configure) configure)
If RacCfgInd is set
0~255 None None UtranExternalCell to CFG, Rac must
be set.
1.
In In
thethe
UtranExternalCell
UtranExternalCell
MO,
MO, PScrambCode
the value of
cannot
CellName exceed 127
is a string
ifofUtranFddTddType
a maximum of 99
is set to
characters. The
UTRAN_TDD.
string cannot be all
0~511 None None UtranExternalCell
2.
nullIncharacters
all or
UtranExternalCell
contain any of the
1~65533,65535 None None UtranExternalCell MOs
None of an eNodeB,
following
the combination
characters: double of
UtranDlArfcn
quotation marks ("), and
0~99 characters NULL None UtranExternalCell PScrambCode
In the ANR
commas (,),MO,mustthe
be
valueunique.
of
semicolons (;),
AddCellThd
equal signs MO, must
(=),
0~100 80 80 ANR In the ANR
be larger
single than
quotation orthe
value
equal of
to
marks
AddCellThd('),that
threeof
must
0~100 60 60 ANR DelCellThd.
consecutive plus
be larger than or
signs
equal (+++),
to that two of or
more consecutive
DelCellThd.
1~10000 200 200 ANR None
blanks, and two or
more consecutive
1~10080 1440 1440 ANR percentage
None signs
(%).
r1, r2, r4, r8, r16,
120ms, r64(64) r64(64) ANR None
r32, r64,240ms,
Infinity
480ms, 640ms,
1024ms, 2048ms,
2048ms 2048ms ANR None
5120ms, 10240ms,
1min, 6min, 12min,
30min,
1~10080 60min 60 60 ANR None
EutranVoipCapSwit EutranVoipCapSwit
-130~-70 -102
ch:On, -102
ch:On ANR None
UtranVoipCapSwitc UtranVoipCapSwitc
EutranVoipCapSwit
h:Off, h:Off
ch,
1~200 5
IntraFreqCoverHoS 5
IntraFreqCoverHoS ANR None
GeranVoipCapSwitc GeranVoipCapSwitc
UtranVoipCapSwitc witch:On, witch:On
h:Off, h:Off
h,
IntraFreqCoverHoS InterFreqCoverHoS InterFreqCoverHoS
1~200 Cdma1xRttVoipCap
5 Cdma1xRttVoipCap
5 ANR None
GeranVoipCapSwitc
witch, witch:On, witch:On
Switch:Off, Switch:Off
h,
InterFreqCoverHoS UtranCsfbSwitch:Of UtranCsfbSwitch:Of
UtranPsHoSwitch:O UtranPsHoSwitch:O
Cdma1xRttVoipCap
witch, f, fff
1~10000 20
ff, 20 ANR None
Switch,
UtranCsfbSwitch, GeranCsfbSwitch:O GeranCsfbSwitch:O
GeranPsHoSwitch: GeranPsHoSwitch:
UtranPsHoSwitch,
GeranCsfbSwitch, ff, ff
Off, Off
GeranPsHoSwitch,
1~10000
Cdma1xRttCsfbSwit
IntraRatEventAnrS 20
Cdma1xRttCsfbSwit
IntraRatEventAnrS 20
Cdma1xRttCsfbSwit
IntraRatEventAnrS ANR None
CdmaHrpdNonOtpi CdmaHrpdNonOtpi
CdmaHrpdNonOtpi
ch,
witch, ch:Off,
witch:Off, ch:Off
witch: Off
misedHoSwitch:Off, misedHoSwitch:Off
misedHoSwitch,
UtranServiceHoSwit
IntraRatFastAnrSwit UtranServiceHoSwit
IntraRatFastAnrSwit UtranServiceHoSwit
IntraRatFastAnrSwit
CdmaHrpdOptimise CdmaHrpdOptimise ENodeBAlgoSwitch None
CdmaHrpdOptimise
ch, ch:Off, ch:Off
ch: Off
dHoSwitch:Off, dHoSwitch:Off
dHoSwitch,
GeranServiceHoSw
IntraRatAnrAutoDel GeranServiceHoSw
IntraRatAnrAutoDel GeranServiceHoSw
IntraRatAnrAutoDel
DlIcicSwitch_OFF_ GeranNaccSwitch: GeranNaccSwitch:
GeranNaccSwitch,
itch,
Switch, itch:Off,
Switch:On, itch:Off On
Switch:
ENUM, Off, Off ENodeBAlgoSwitch None
GeranNonNaccSwit
CdmaHrpdServiceH
UtranEventAnrSwitc CdmaHrpdServiceH
UtranEventAnrSwitc CdmaHrpdServiceH
UtranEventAnrSwitc
DlIcicDynamicSwitc GeranNonNaccSwit GeranNonNaccSwit
ch,
oSwitch,
h, oSwitch:Off,
h:Off, oSwitch:Off
h: Off
h_ON_ENUM, ch:Off,
DlIcicSwitch_OFF_ ch:Off
DlIcicSwitch_OFF_
UtranSrvccSwitch,
Cdma1xRttService
GeranEventAnrSwit Cdma1xRttService
GeranEventAnrSwit Cdma1xRttService
GeranEventAnrSwit ENodeBAlgoSwitch None
DlIcicStaticSwitch_ UtranSrvccSwitch:O
ENUM UtranSrvccSwitch:O
ENUM
GeranSrvccSwitch,
HoSwitch,
ch, HoSwitch:Off,
ch:Off, HoSwitch:Off
ch: Off
ON_ENUM, ff, ff
Cdma1xRttSrvccSw
UlPowerHoSwitch,
UtranFastAnrSwitch UlPowerHoSwitch:
UtranFastAnrSwitch UlPowerHoSwitch:
UtranFastAnrSwitch
DlIcicReuse3Switch GeranSrvccSwitch: GeranSrvccSwitch: ENodeBAlgoSwitch None
itch,
,InterPlmnHoSwitch Off,
:Off, :Off
Off
_ON_ENUM Off, Off
UtranRedirectSwitc
GeranFastAnrSwitc InterPlmnHoSwitch:
GeranFastAnrSwitc InterPlmnHoSwitch:
GeranFastAnrSwitc
Cdma1xRttSrvccSw
LOAD_BASED_RE
IntraFreqMroAlgoS Cdma1xRttSrvccSw
LOAD_BASED_RE
h,
LOAD_BASED_RE
h, Off
h:Off, IntraFreqMroAlgoS
Off
h: Off
itch:Off,
DIRECT_SWITCH:
witch:Off, itch:Off
DIRECT_SWITCH: ENodeBAlgoSwitch None
GeranRedirectSwitc
DIRECT_SWITCH
IntraFreqMroSwitch
CdmaFastAnrSwitc CdmaFastAnrSwitc witch:Off
CdmaFastAnrSwitc
UtranRedirectSwitc
Off
InterFreqMroAlgoS UtranRedirectSwitc
Off
,h,
h, h:Off, InterFreqMroAlgoS
h: Off
h:Off
CdmaHrpdRedirect witch:Off,
InterFreqMroSwitch
UtranAutoNrtDelete UtranAutoNrtDelete
GeranRedirectSwitc witch:Off
UtranAutoNrtDelete
GeranRedirectSwitc ENodeBAlgoSwitch None
Switch, UtranMroSwitch:Off
,Switch,
UtranMroSwitch, Switch:On, UtranMroSwitch:Off
Switch:
h:Off On
Cdma1xRttRedirect ,h:Off,
GeranMroSwitch
GeranAutoNrtDelet GeranAutoNrtDelet
CdmaHrpdRedirect GeranMroSwitch:Of
GeranAutoNrtDelet
CdmaHrpdRedirect
TpeAlgoSwitch
Switch, GeranMroSwitch:Of
TpeAlgoSwitch:Off TpeAlgoSwitch:Off ENodeBAlgoSwitch None
eSwitch, eSwitch:On,
Switch:Off, feSwitch:
Switch:OffOn
BlindHoSwitch f
CdmaAutoNrtDelete CdmaAutoNrtDelete
Cdma1xRttRedirect CdmaAutoNrtDelete
Cdma1xRttRedirect
Switch Uplink Intra-eNB
Switch:On
Switch:Off, Uplink
Switch: Intra-eNB
On
Switch:Off
UlIcicIntraSwitch ENodeBAlgoSwitch None
ICIC switch:Off
BlindHoSwitch:Off ICIC switch:Off
BlindHoSwitch:Off
OFF, STATIC,
OFF(Off) OFF(Off) ENodeBAlgoSwitch None
DYNAMIC

OtdoaSwitch OTDOA switch:Off OTDOA switch:Off ENodeBAlgoSwitch None

UU flow control UU flow control


UlUuFlowCtrlSwitch ENodeBAlgoSwitch None
switch:Off switch:Off

OFF, ON OFF(Off) OFF(Off) ENodeBAlgoSwitch None

1~70000 1440 1440 MRO None

0~100 99 99 MRO None

0~10000 1000 1000 MRO None

1~60 5 5 MRO None

0~100 5 5 MRO None

0~9 None None SimuLoad None

0~100 50 None SimuLoad None

0~100 50 None SimuLoad None

0~50000 500 500 SimuLoad None

0~50000 5000 5000 SimuLoad None

OFF, ON OFF(Off) OFF(Off) SimuLoad None

0~261120 0 0 TddFrameOffset None

0~20 3 3 TpeAlgo None

0~65535 20 20 TpeAlgo None

0~65535 80 80 TpeAlgo None

0~65535 8080 8080 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None


0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo None

0~65535 0 0 TpeAlgo The


Nonevalue of URL in
the CA MO cannot
contain any space
1~127 characters None None CA None
and must begin with
http:// or https://.
The IP address in
1~128 characters None None CA
URL must be a
valid IPv4 address.
0~47 None None NODETORSCGRP The
Noneport number in
URL must be a
value in the range
SGW, X2eNodeB None None NODETORSCGRP None
of 1 to 65535.
EndPointId is valid
only when
NO, YES None None NODETORSCGRP
IsAllMatch is set to
NO.
0~47 None None NODETORSCGRP None

0~7 0 0 NODETORSCGRP None

0~1 0 0 NODETORSCGRP None

0~7 None None NODETORSCGRP None


In the
In the
NODETORSCGRP
NODETORSCGRP
IP None None NODETORSCGRP None
MO,
MO, ifif SN PT isis set
within
to
the range
PPP, from 0 to
the value
0~15 None None NODETORSCGRP 5,
range
None this ofparameter
this
must be setistofrom 0
parameter
In
to the
E1_COVERBOARD
15.
BASE_BOARD, NODETORSCGRP
None None NODETORSCGRP .In the
E1_COVERBOARD MO,
In theif SBT is set to
NODETORSCGRP
BASE_BOARD,
NODETORSCGRP
MO, if PT is set to this
0~15 0 0 NODETORSCGRP parameter
MO, if SNthe can
is set be
to 6
MPGRP, value
set
opr
range to
7, ETH
of thisor
this
PPP, MPGRP, ETH, ETHTRK.
parameter
parameter must is from be0
None None NODETORSCGRP
ETHTRK In
setthe
When
to 3.to Active is set
NODETORSCGRP
to ACTIVE,
BASE_BOARD.
In the only
0~1 None None DOT1X MO,
None if
Extensible SBT
NODETORSCGRP is set to
E1_COVERBOARD
Authentication
MO, if PT is set to
DEACTIVE, ,ETH
this or
Protocolparameter
- Transport
ETHTRK, can
ACTIVE(Active) None DOT1X None
be
ACTIVE thisset
Layer to PPP or
Security
parameter can
MPGRP.
(EAP-TLS)
be set to 0 or method
1.
EAP-INVALID, EAP-TLS(EAP-TLS EAP-TLS(EAP-TLS is supported.
DOT1X
EAP-TLS authentic method) authentic method) When Active is set
to DEACTIVE only
0~4294967295 None None DOT1X Extensible
None
Authentication
Protocol - INVALID
0~4294967295 None None DOT1X None
(EAP-INVALID)
NULL, LIC_OFF, method is
NOTIFY_FAIL, supported.
None None DOT1X None
NO_CERT,
UNAUTHENTICAT
PORT_DOWN
ED,
0~4294967295 None None DOT1X None
AUTHENTICATING
,
AUTHENTIC_SUC None None DOT1X None
CEED,
AUTHENTIC_FAIL,
0~4294967295
DHCP_AUTHENTI None None DOT1X None
CATING
0~4294967295 None None DOT1X None

1~100 25 25 LicRatio None

SHARING,
SHARING(Sharing) SHARING(Sharing) LicRatio None
DEDICATE
The total proportion
of traffic of all
0~100 0 0 LicRatio
operators can not
The total100%.
exceed proportion
of traffic of all
0~100 0 0 LicRatio
operators can not
The total100%.
exceed proportion
of traffic of all
0~100 0 0 LicRatio
operators can not
The total100%.
exceed proportion
of traffic of all
0~100 0 0 LicRatio
operators
OP1TRAFFICSHAcan not
exceed 100%.
RRATIO can not be
0~100 0 0 LicRatio more than
OP2TRAFFICSHA
OP1TRAFFICRATI
RRATIO
O. can not be
0~100 0 0 LicRatio more than
OP2TRAFFICRATI
O.
set to a value
different from the IP
parameter in any
DEVIP MO.
The FirstSigIP
parameter in the
OP3TRAFFICSHA
MME MO must be
RRATIO
set can not be
to a value
0~100 0 0 LicRatio more than
different from the
OP4TRAFFICSHA
OP3TRAFFICRATI
FirstSigIP
RRATIO
O.
parameter can in not
any be
0~100 0 0 LicRatio FirstIKEPeerName
more than
other
and MME MO.
OP4TRAFFICRATI
The FirstSigIP
FirstIKEPeerName
FirstIPSecPropNam
O.
SecSigIP ininan
0~15 None None MME parameter
and
None
e are valid only the
MME
MME MO
MO
FirstIPSecPropNammust
must be
be
when
set to a value
set
e areto a value
valid
FirstIPSecFlag only is
Valid IP address None None MME FirstIKEPeerName
different
different
when from
from IP thein
set
and
any to ENABLE.
DEVIP MO.is
SecSigIP
FirstIPSecFlag
FirstIKEPeerNameparameter
DISABLE(Disable) FirstIPSecPropNam
SecSigIP
in
set any
to otherin an
ENABLE. MME
DISABLE, ENABLE DISABLE(Disable) if IPSec is not MME must
e
MMEare refer
valid
MO must to
only a be
MO.
FirstIPSecPropNam
configured
supported when
set
The
e toFirstSigIP
must arefer
valueto a
IKEPEER.
FirstIPSecFlag
0~15 characters None None MME
different
parameter
configured
If the
from in theis
set
MME to
FirstSigIPENABLE.
MO
IPSECPROPOSAL.
SecIKEPeerName in
must anybe
FirstIPSecFlag
other MME MO.
set
If
andtheto
parameter a value
0~15 characters None None MME SecSigIP
different
FirstIPSecFlag
SecIPSecPropNam ininan
from
the
theto
MME
MME MO
MO mustis set be
This parameter is FirstSigIP
parameter
e are
ENABLE, valid in
only
the the
set
MME
when to
parameter a
MO value
isinset
SecIPsecFlag anyto
not required if FirstIKEPeerName
SecIKEPeerName
Valid IP address 0.0.0.0 MME different
X2eNodeB
ENABLE,
is set to from
the
ENABLE. MO.
SCTP multi-homing parameter
and
SecSigIP
The in any be
FirstSigIP
FirstIPSecPropNam
SecIKEPeerName
must
is not supported. set to
DISABLE(Disable)
e MMEvalue
the
SecIPSecPropNam
other
parameter
parameter
must refer in
toMO.the
must
a
of
DISABLE, ENABLE DISABLE(Disable) if IPSec is not MME the
e arePeerName
SecSigIP valid in only
an be
supported MME
be setMO
configured to the
SecIKEPeerName
parameter
when must
in value
anbe
MME
set
of MO
to a value
the
IKEPEER. must
and
existing
SecIPSecFlag IKEPEER is
0~15 characters None None MME set
If theto SecIPSecFlag
different a value
ProposalName from the
SecIPSecPropNam
MO.
set to ENABLE.
different
SecSigIP from
e are validparameter
parameter in
only an
the
FirstSigIP
in any
existing
MME in set
X2eNodeB
MO is anyto
when SecIPsecFlag
0~15 characters None None MME X2eNodeB
MO.
IPSECPROPOSAL
ENABLE, the MO.
is set to ENABLE.
SecSigIP
MO.
SecIKEPeerName in an
SecIPSecPropNam
MME
parameter MO must
must be
1024~65535 None None MME e must refer
None to abe
set
set to
to a
thevalue
value of
configured
different
The
the from
OperatorId
PeerName
IPSECPROPOSAL.
SecSigIP
parameter
parameter inin any
the
0~20 characters None None MME None
S1ServIP
X2eNodeB
MME MO ininMO.
must
an
the be
existing
S1ServIP IKEPEER
MO
set
MO. to the same
0~3 0 None MME LocIKEIP
cannot
value asbethe isset valid
to
only
0.0.0.0.when
CnOperatorId
IPSecFlag
The S1ServIP
parameter is an
in set to
0~7 0 0 S1ServIP ENABLE.
None
parameter
existing CnOperatorin the
If the IPSecFlag
S1ServIP
MO. MO must
parameter
be set to the in same
the
0~1 0 0 S1ServIP None
S1ServIP
value as the IPis set
MO
to ENABLE,inthe
parameter an
LocIKEIP
existing DEVIP MO.
0~7 None 7 S1ServIP None
parameter
The valuesmust of thebe
set to the same
CabinetNo,
Valid IP address None None S1ServIP value
SubrackNo,as the and IP
parameter
SlotNo in
parameters
LocIKEIP is valid an
DISABLE(Disable) existing
in the DEVIP
S1ServIP MO.
MO
only when
DISABLE, ENABLE DISABLE(Disable) if IPSec is not S1ServIP If the be
must IPSecFlag
theissame
IPSecFlag set to
supported parameter
as those ofinthe the
ENABLE.
S1ServIP
CabinetNo, is setMO
Valid IP address 0.0.0.0 None S1ServIP
to ENABLE, and
SubrackNo, the
values
SlotNo of the
parameters
0~7 0 0 S1SigIP CabinetNo,
respectively
None in the
SubrackNo,
DEVIP MO that andis
SlotNo
associated parameters
with the
0~1 0 0 S1SigIP None
in the S1ServIP MO
S1ServIP
must
parameterbe theinsame the
as those ofMO.
S1ServIP the
0~7 None 7 S1SigIP None
CabinetNo,
SubrackNo, and
SlotNo parameters
respectively in the
DEVIP MO that is
associated with the
LocIKEIP
parameter in the
parameter in the
If the LocIPSecFlag
S1SigIP
parameter in must
MO the
be set to MO
S1SigIP the is same set
value as the the
to ENABLE,
SecLocIKEIP IPis
parameter
LocIKEIP
valid in an
In an only
S1SigIP when MO,
existing
parameter DEVIP MO.
the value ofmust be
SecLocIPSecFlag
The
setset
is values
to to
theENABLE.
sameof the
SecLocIP cannot
CabinetNo,
value
Valid IP address None None S1SigIP If
be theas
the samethe IP as that
SubrackNo,
parameter and
LocIP. isinvalid
SecLocIPSecFlag
of
LocIKEIP an
DISABLE(Disable) SlotNo
existing
parameter parameters
DEVIP theMO.
SecLocIP
only when ininan
DISABLE, ENABLE DISABLE(Disable) if IPSec is not S1SigIP in
If the LocIPSecFlag
the
S1SigIP S1SigIP
MO is MO
LocIPsecFlag
must be the sameisset
must set
supported parameter
to
be ENABLE,
set to the inthe
the
same
to
as ENABLE.
those MO of the set
S1SigIP as IP inisan
SecLocIKEIP
value
Valid IP address 0.0.0.0 None S1SigIP CabinetNo,
to ENABLE,
parameter
existing DEVIP theMO.
must be
This parameter is SubrackNo,
values
set of the and
Thetovalues
the sameof
not required if SlotNo asparameters
CabinetNo,
value the IP
Valid IP address 0.0.0.0 S1SigIP CabinetNo,
SCTP multi-homing respectively
SubrackNo,
parameter inanthe
and
inand
SubrackNo,
SecLocIKEIP is is
is not supported.
DISABLE(Disable) DEVIP
SlotNo
existing MO that
parameters
DEVIP MO.
SlotNo
valid in
only an
when
DISABLE, ENABLE DISABLE(Disable) if IPSec is not S1SigIP associated
in
If the
the S1SigIP withMO the
S1SigIP MO
SecLocIPSecFlag must
supported LocIP
must beparameter
the
SecLocIPSecFlag same in
beset
is thetosame
ENABLE. as
the
as S1SigIP
those
parameter MO.
ofinthe the
Valid IP address 0.0.0.0 None S1SigIP those of CabinetNo,
CabinetNo,
S1SigIP
SubrackNo, MOand is set
SubrackNo,
to ENABLE,
SlotNo and
the
respectively
1024~65535 None None S1SigIP SlotNo
values
in
None parameters
of
the DEVIP the MO
respectively
CabinetNo,
that is associated in the
DEVIP
with SecLocIP inis
SubrackNo, MO that
and
1000~60000 1000 1000 S1SigIP None
associated
SlotNo
the with
MO.the
parameters
S1SigIP
LocIKEIP
in the S1SigIP MO
parameter
must be theinsame the
1000~60000 3000 3000 S1SigIP None
S1SigIP
as those MO.of the
CabinetNo,
1000~60000 1000 1000 S1SigIP SubrackNo,
None and
SlotNo parameters
respectively in the
1~99 12 12 S1SigIP None MO that is
DEVIP
associated with the
SecLocIKEIP
1~99 25 25 S1SigIP None
parameter in the
S1SigIP MO.
1000~60000 5000 5000 S1SigIP None
MaxAssocRetr must
2~254 10 10 S1SigIP be greater than
MaxPathRetr.
MaxPathRetr must
1~253 5 5 S1SigIP The
be lessServIP1
than
parameter
MaxAssocRetr. in the
SGW MO must be
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) S1SigIP None
set to a value
different from the IP
parameter in any
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) S1SigIP None
existing DEVIP MO.
The ServIP1
ALDER32, CRC32 CRC32(CRC32) CRC32(CRC32) S1SigIP parameter
None in the
SWITCHBACKHBN
SGW MO must be
UM is valid only
set to a value
when
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) S1SigIP different from the
SWITCHBACKHBN
SWITCHBACKFLA
ServIP1
UM parameter
G is set to only
is valid
in any other existing
when
1~254 10 10 S1SigIP ENABLE.
SGW MO.
SWITCHBACKFLA
The
G is ServIP1
set to
0~15 None None SGW parameter
ENABLE.
None in the
SGW MO must be
set to a value
Valid IP address None None SGW ServIP1IKEPeerNa
different from the
me and parameter
ServIP2
DISABLE(Disable) ServIP1IPSecProp
in any other existing
DISABLE, ENABLE DISABLE(Disable) if IPSec is not SGW Name
SGW MO. are valid only
supported when
The ServIP1
ServIP1IPSecFlag
parameter in the
is
SGWset toMOENABLE.
must be
set to a value
different from the
ServIP3 parameter
in any other existing
me and DEVIP MO.
existing
ServIP1IKEPeerNa
ServIP1IPSecProp
Theand
me ServIP2
Name
parameter are valid
in theonly
ServIP1IPSecProp
when
SGW
Name MO
are must
valid be only
ServIP1IPSecFlag
set to a value
when
is
The setServIP3
to ENABLE.
different from the
ServIP1IPSecFlag
If the
parameter
ServIP1 in the
parameter
is set to ENABLE.
ServIP1IPSecFlag
SGW MO must be
in
If any
the other existing
0~15 characters None None SGW parameter
set
SGW to MO.
a value in the
ServIP1IPSecFlag
SGW
different MOfrom is set thetoIP
The ServIP2
parameter
ServIP2IKEPeerNa in the
ENABLE,
parameter
parameter the
in any
0~15 characters None None SGW SGW
me and MO
ServIP1IKEPeerNa
existing isinset
DEVIP
theto
MO.
SGW MO
ServIP2IKEPeerNa
ENABLE,
ServIP2IPSecProp must
the be
me
Theto
set
me parameter
ServIP3
and a value must
ServIP1IPSecProp
Name
be are
set to from
the
ServIP2IKEPeerNa
parameter valid
in value
the only
Valid IP address 0.0.0.0 None SGW different
ServIP2IPSecProp
Name
when parameter the
of
me
SGW the
and
ServIP2
Name PeerName
MO
are must be
parameter
DISABLE(Disable) must
parameterbe setvalid
ServIP2IPSecFlag
ServIP2IPSecProp
set to a value into
only
anthe
in
when
is
The any
value other
of the
setServIP4
to ENABLE. existing
DISABLE, ENABLE DISABLE(Disable) if IPSec is not SGW existing
Name
different
SGW MO.IKEPEER
arefrom
ServIP2IPSecFlag valid theonly
supported ProposalName
If
MO.the
parameter
when
ServIP1 in the
parameter
The
is set ServIP2
parameterto ENABLE.
ServIP2IPSecFlag
SGW inexisting
anbe
anyMO
ServIP2IPSecFlag
in
parameter
If the other must
in the
0~15 characters None None SGW existing
parameter
set
is
SGW to
set toa
MO.value in
ENABLE. the
SGW
different MO
ServIP2IPSecFlag
IPSECPROPOSAL
SGW MO must
is
from setthebe
toIP
The
set toServIP3
parameter a value
ServIP3IKEPeerNa in the
MO.
ENABLE,
parameter
parameter the
in any
0~15 characters None None SGW different
SGW
me and MO
ServIP2IKEPeerNa
existing isinset
from
DEVIP
the
the to
MO.
SGW
ServIP3
ENABLE, MO
ServIP3IKEPeerNa must
parameter
ServIP3IPSecProp the be
me
The
set
me parameter
toServIP4
and aother
value must
in
be any
ServIP2IPSecProp
Name set are
to from
the
ServIP3IKEPeerNa
parameter inexisting
valid only
value
the
Valid IP address 0.0.0.0 None SGW different
ServIP3IPSecProp
SGW
Name
when MO.
parameter the
of
me
SGW the
and
ServIP2
Name PeerName
MO
are must be
parameter
DISABLE(Disable) The
must be setvalid
ServIP2
ServIP3IPSecFlag
parameter
ServIP3IPSecProp
set to a value into
only
anthe
in
whenany
parameter
value
is set to other
of the existing
in the
ENABLE.
DISABLE, ENABLE DISABLE(Disable) if IPSec is not SGW existing
Name
different
SGW MO.IKEPEER
arefrom
ServIP3IPSecFlag valid theonly
supported SGW
MO.the
when
ServIP1 MO
ProposalName
If must
parameter be
The
is
set set ServIP3
to ENABLE.
to aother
parameter value
ServIP3IPSecFlag inexisting
an
ServIP3IPSecFlag
in
If any
parameter
the in the
0~15 characters None None SGW different
existing
parameter
is
SGW set toMO. from in
ENABLE. the
the
SGW MO
ServIP3IPSecFlag
ServIP4
IPSECPROPOSAL
SGW MO must
parameter
is set be
to
The
set toServIP4
parameter a value
ServIP4IKEPeerNa in the
in
MO. any
ENABLE,
parameter other the existing
0~15 characters None None SGW different
SGW
me
SGW and MO
MO.
ServIP3IKEPeerNa isinset
from the
theto
SGW
ServIP3
ENABLE, MO
ServIP4IKEPeerNa must
parameter
ServIP4IPSecProp the be
me
set
me parameter
to
and aare
value must
in
be any other
ServIP3IPSecProp
Name set to from existing
valid
the value
ServIP4IKEPeerNa only
Valid IP address 0.0.0.0 None SGW different
ServIP4IPSecProp
SGW
Name
when MO.
parameter the
of
me
Namethe
and
ServIP2 PeerName
areparameter
DISABLE(Disable) The
must setvalid
ServIP3
be
ServIP4IPSecFlag
parameter
ServIP4IPSecProp into
only
anthe
in
whenany
parameter
value
is set to other
of the existing
in theonly
ENABLE.
DISABLE, ENABLE DISABLE(Disable) if IPSec is not SGW existing
Name
SGW IKEPEER
are
MO.
ServIP4IPSecFlag valid
supported SGW
If
MO.the MO
ProposalName
when must be
The
is toServIP4
set
SeGWFlag
set
parameterto ENABLE.
a value
ServIP4IPSecFlag inandan
ServIP4IPSecFlag
parameter
If the in the
0~15 characters None None SGW LocIKEIP
different
existing
parameter are
from in valid
the
the
is
SGW set toMO ENABLE.
must
ServIP4IPSecFlag
only
ServIP4 when is set be
MOparameter
IPSECPROPOSAL
SGW to
set to aother
parameter
IPSecFlag
in any
MO.
ENABLE, value in the
isexisting
the set to
0~15 characters None None SGW different
SGW
ENABLE.
SGW MO
MO. from
ServIP4IKEPeerNa is set theto
ServIP3
ENABLE,
If
me the parameter
the must
IPSecFlag
parameter
in any
set other
ServIP4IPSecProp
parameter
be to the inexisting
the
value
0~20 characters None None SGW None
OperatorId
SGW
Name
X2ServIP MO.
parameter
in
MO inan the
is set
of the PeerName
SGW
The
must MOset
ServIP4 must be
parameter in anthe
X2ServIP
to be
ENABLE, MO to
the
the
cannot
valuessame
parameter
value ofof
the
be as in the
set
the to
0~3 0 None SGW existing IKEPEER
CnOperatorId
SGW in an
MO. MO must be
ProposalName
0.0.0.0.
CabinetNo,
existing
set to
parameter
The a CnOperator
value
X2ServIP
SubrackNo, and in an
0~7 0 0 X2ServIP MO.
different
existing from
None parameters
parameter
SlotNo in thethe
ServIP4
IPSECPROPOSAL
X2ServIP
in parameter
the X2ServIP MO must MO
in any
MO.
be
must setbe other
tothe
thesameexisting
same
0~1 0 0 X2ServIP None
SGW
value
as thoseMO.
as the
of the IP
parameter in an
CabinetNo,
0~7 None 7 X2ServIP existing
SubrackNo,
None DEVIP andMO.
SeGWFlag
The values
SlotNo and
of the
parameters
LocIKEIP
CabinetNo,
respectively areinvalidthe
Valid IP address None None X2ServIP only when
SubrackNo,
DEVIP MO and
that is
SeGWFlagisand
IPSecFlag settheto
SlotNo
associated
LocIKEIP parameters
arewith valid
DISABLE(Disable) ENABLE.
in thewhen
LocIKEIP X2ServIP MO
DISABLE, ENABLE DISABLE(Disable) if IPSec is not X2ServIP only
IKEPeerName and
must
parameter
IPSecFlagbe theinissame
the
set to
supported IPSecPropName
as those ofMO.
X2ServIP the
ENABLE.
are valid only when
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2ServIP CabinetNo,
If the IPSecFlag
IKEPeerName and
both IPSecFlag
SubrackNo,
parameter inandtheand
IPSecPropName
SeGWFlag are
SlotNo
are validparameters
X2ServIP MO when
only isset
set
Valid IP address 0.0.0.0 None X2ServIP to
to ENABLE.
respectively
ENABLE, in
the the
both IPSecFlag and
DEVIP
PortType
SeGWFlag MO that
parameter
are setis
associated
in the
to ENABLE.DEVIP withMO the
X2ServIP with the
associated
parameter in the
LocIKEIP
X2ServIP MO.
parameter in the
X2ServIP MO must
be set to
3(TLM_IPITFTYPE
IPSecPropName
are valid only
IKEPeerName
SeGWFlag and when
and
both IPSecFlag
IPSecPropName
LocIKEIP are valid and
SeGWFlag
are valid
only whenonly when are set
to
bothENABLE.
IPSecFlagIPSecFlag is setand to
If both
SeGWFlag the
ENABLE. are set
IPSecFlag
to ENABLE.and
If IPSecFlag in an
SeGWFlag
If both
X2SigIP theMO is set
0~15 characters None None X2ServIP parameters
IPSecFlag
to ENABLE,and in the
The LocIPMO are
X2ServIP
SeGWFlag
LocIKEIP must be
parameter
set
SecSeGWFlag ininthe
0~15 characters None None X2ServIP set toto ENABLE,
parameters the same theand
the
X2SigIP
IKEPeerName
SecLocIKEIP
X2ServIP MO MO cannot
are
are
value as IP in an
be
set set
parameter
valid toonlyto 0.0.0.0.
ENABLE,when
mustMO. be
the
existing DEVIP
The
set LocIP
SecIPSecFlag
to the
IPSecPropName value isof
0~7 0 0 X2SigIP None
If IPSecFlag in an
parameter
the
set to
PeerName
parameter ENABLE. in
must thebe
X2SigIP MO is set
X2SigIP
parameter
If
settheto the MO in
value must
an of
to ENABLE, the
0~1 0 0 X2SigIP be
None
the set
existing toIKEPEER
SecLocIPSecFlag the same
ProposalName
values of
value
MO.
parameter as the in IP
CabinetNo,in
parameter the
an
parameter
X2SigIP
existing MO in anset
is
0~7 None 7 X2SigIP SubrackNo,
None and
existing
to ENABLE,
SeGWFlag
IPSECPROPOSAL DEVIP andthe MO.
SlotNo in the
The valuesare
SecLocIKEIP
LocIKEIP
MO. of valid
the
X2SigIP MO must
CabinetNo,
parameter must
Valid IP address None None X2SigIP only
be the
SeGWFlag
whensame and as be
SubrackNo,
set to
IPSecFlag the same
is and
set to
those of CabinetNo,
LocIKEIP areIPvalid
DISABLE(Disable) SlotNoasparameters
value
ENABLE.
IKEPeerName the and
SubrackNo,
In
onlyan X2SigIP andMO,
DISABLE, ENABLE DISABLE(Disable) if IPSec is not X2SigIP in thewhen
parameter
IKEPeerNameX2SigIP
IPSecPropName in an MO
and
SlotNo
the value
IPSecFlag respectively
ofissame set to
supported must
existing be
IPSecPropName
are valid
IKEPeerName the
DEVIP
only MO.
when
and
in the DEVIP
SecLocIP,
ENABLE. ifthe MO
valid,
as
If
are those
the
both valid of
only when
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2SigIP that
must isIPSecFlag
IPSecPropName
be
IKEPeerName associated
different and
and
CabinetNo,
SecLocIPSecFlag
both IPSecFlag
SeGWFlag
are valid
with LocIKEIP
from only
that of LocIP.
IPSecPropName
are inand
set
when the
SubrackNo,
parameter
SeGWFlag
to
bothENABLE.
IPSecFlag and
inare theset
and
X2SigIP
SecLocIP,
are valid MO.
onlyif valid,
when in
SlotNo
X2SigIP
to
If ENABLE.
both
SeGWFlag parameters
theMOare is set
set
Valid IP address 0.0.0.0 0.0.0.0 X2SigIP If
an IPSecFlag
both X2SigIP
IPSecFlag MO in an
and
respectively
to ENABLE,
IPSecFlag
to ENABLE. and in
the the
X2SigIP
must
SeGWFlag beMO MO
set is the
to
are set
set
DEVIP
values
SeGWFlag
If both of the
the that is
to
same
to ENABLE,
value
ENABLE. as IP in
0~15 characters None None X2SigIP associated
CabinetNo,
parameters with
in the
IPSecFlag
PortType
an existing inand thethe
DEVIP
LocIP
SubrackNo,
X2SigIP
SeGWFlag parameter
MOand are set in
DEVIP MO
MO.
the
SlotNo
to X2SigIP
ENABLE,
SecSeGWFlag
parameters parameters MO.
inthe and
0~15 characters None None X2SigIP associated
If SecLocIPwith in the
an
in the X2SigIP
IKEPeerName
SecLocIKEIP
X2SigIP
LocIKEIP MO in the are MO
are set
X2SigIP MO is
This parameter is must
parameter
valid
to be
only
ENABLE, the must
when same
the be
X2SigIP
valid, the
SecSeGWFlag MOvalues must of
not required if multi- as
set those
to the
SecIPSecFlagto of
IPSecPropName
be set valuethe isandof
Valid IP address 0.0.0.0 X2SigIP CabinetNo,
SecLocIKEIP are
homing is not CabinetNo,
the
set PeerName
to ENABLE.
SecIKEPeerNam
parameter must be
3(TLM_IPITFTYPE
SubrackNo,
valid only when and
supported.
DISABLE(Disable) SubrackNo,
parameter
SecIKEPeerName
and
set toor the inand
value an of
_FE)
SlotNo
SecIPSecFlag
SecIKEPeerNamin the is
DISABLE, ENABLE DISABLE(Disable) if IPSec is not X2SigIP SlotNo
existing
and parameters
IKEPEER
SecIPSecPropNam
the ProposalName
5(TLM_IPITFTYPE
X2SigIP
set
and to MO must
ENABLE.
supported respectively
MO.
SecIPSecPropNam
e are inanthe
be thevalid
parameter
_ETHTRK). same
SecIKEPeerNam
SecIPSecPropNam
only
in as
DEVIP
e are
when
existing
If MO
valid
both
IPSecFlag that
only in is
an
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2SigIP those
and
e are of
validCabinetNo,
only
associated
when both
SecIPSecFlag
IPSECPROPOSAL
X2SigIP MOand withis andthe
set
SubrackNo,
SecIPSecPropNam
when both
SecLocIKEIP
SecIPSecFlag
SecSeGWFlag
MO.
to ENABLE, and
are
PortNo
SlotNo
e are respectively
Valid IP address 0.0.0.0 None X2SigIP set
in to valid
SecIPSecFlag
parameter
SecSeGWFlag
the ENABLE.
DEVIP
only
in the
MO
and
are
when
X2SigIP
set
If to
both both
SecSeGWFlag MO.
ENABLE.
the are
associated
that is ENABLE.
SecIPSecFlag
set to associatedwithand
If the
SecIPSecFlag
LocIKEIP and
0~15 characters None None X2SigIP
with
SecSeGWFlag
If both thein theinare
SecLocIP
SecLocIPSecFlag
SecSeGWFlag
X2SigIP
the
set X2SigIP MO
to ENABLE.
SecIPSecFlag must
MO. and
parameter
parameters in same
the
be set to the
SecLocIP
SecSeGWFlag inin anthe
X2SigIP
X2SigIP
value as MOMO
MO
PortNo is
are setset
0~15 characters None None X2SigIP X2SigIP
parameters
to
to ENABLE,
ENABLE, thein
cannot
inthe
the
the
be DEVIP
set
X2SigIP to MO MO
0.0.0.0. are set
PortType
SecIKEPeerName
associated parameter
with
to
in ENABLE,
the
parameter DEVIP the
MObe
1024~65535 36422 36422 X2SigIP LocIP
None in themust
SecIPSecPropNam
associated
set to
X2SigIP the with
value
MO.must the
of
e parameter
SecLocIKEIP
the PeerName
LocIKEIP
be set to the in an value
1000~60000 1000 1000 X2SigIP parameter
parameter
None
In the X2SigIP
X2SigIP MO in the
in cannot
anMO,
of the
X2SigIP
existing MO
IKEPEER must
the
be value
set to of the
0.0.0.0.
ProposalName
be
MO.set toparameter
RtoMax
1000~60000 3000 3000 X2SigIP parameter
3(TLM_IPITFTYPE in an
must be larger than
existing
_FE)
that oforthe RtoMin
IPSECPROPOSAL
5(TLM_IPITFTYPE
1000~60000 1000 1000 X2SigIP parameter.
None
MO.
_ETHTRK).
If the
1~99 12 12 X2SigIP SecLocIPSecFlag
None
parameter in the
X2SigIP MO is set
1~99 25 25 X2SigIP None
to ENABLE, the
PortNo parameter
in the DEVIP MO
associated with the
SecLocIKEIP
parameter in the
X2SigIP MO must
be set to the same
value as the PortNo
1000~60000 5000 5000 X2SigIP None
The LocIP
MaxAssocRetr must
2~254 10 10 X2SigIP In
bethe
parameter
greaterX2SigIP in
than theMO,
the valueMO
X2SigIP
MaxPathRetr. of the cannot
MaxPathRetr
be set to 0.0.0.0.
1~253 5 5 X2SigIP parameter
The FirstSigIP must be
smaller
parameter in that
than the of
the MaxAssocRetr
X2eNodeB MO
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2SigIP None
parameter.
must be set to a
valid IP address.
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2SigIP The
NoneFirstSigIP
parameter in the
X2eNodeB MO
ALDER32, CRC32 CRC32(CRC32) CRC32(CRC32) X2SigIP None be set to a
SWITCHBACKHBN
must
In
UManisX2eNodeB
value
FirstIKEIP validisonly
different from
valid
MO,
when
the
only the
IPwhen value of in
parameter
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) X2SigIP SWITCHBACKHBN
SecSigIP,
any DEVIPif MO.
SWITCHBACKFLA
FirstIPSecFlag valid, is
UM
must
G
The is is be
setvalid
value
set to ENABLE to of only
different theand
when
from
ENABLE. that of
FirstSigIP
FirstSeGWFlag is
1~254 10 10 X2SigIP The X2eNodeBID
SWITCHBACKFLA
FirstSigIP.
parameters
set to DISABLE. in the
parameter
G is to ifinMO the in
In theset
SecSigIP,
X2eNodeB
X2eNodeB X2eNodeB valid,
MO
16~47 None None X2eNodeB ENABLE.
an X2eNodeB
cannot
MO, be
if the the MO
same
cannot
must be be set the to same
a in
as the
FirstSeGWFlag
as that FirstSigIP
FirstIPSecFlag is
valid
any IPin
other
parameter
any other
address.
is set
Valid IP address None None X2eNodeB valid
X2eNodeB
The
only when
FirstSeGWFlag
SecSigIP MOs. isto
X2eNodeB
ENABLE
FirstIPSecFlag
valid and
only when MO. theis
parameter
SecIKEIPvalue
FirstSeGWFlag
The isinvalid
of the
the
DISABLE(Disable) set toServIP1,
ENABLE.
FirstIPSecFlag is
X2eNodeB
only whenServIP3,
FirstSigIP
parameter
ServIP2, MO
both set thatto
DISABLE, ENABLE DISABLE(Disable) if IPSec is not X2eNodeB FirstIKEIP
set to ENABLE, is valid
must
parameters
DISABLE,
or be setthe
SecIPSecFlag
ServIP4 to the
in a
is
supported only
is, the when
actual both value
value
set to different
X2eNodeB
FirstIKEIP
parameter ENABLE inMO thefrom
and
FirstIPSecFlag
of FirstIPSecFlag and is
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2eNodeB the
cannotIP
SecSeGWFlag
parameter
X2eNodeB parameter
be the
must
MO is
samebe in
FirstSeGWFlag are
1.
any
set
as
set
cannot DEVIP
to
the
to DISABLE.
aSecSigIP
bevalid theMO. IPsame in
FirstIKEIP ENABLE. isan valid
SecSigIP
In
any theother
address.
as any of in
X2eNodeB
the
Valid IP address 0.0.0.0 None X2eNodeB only
X2eNodeB
MO, when both
MO
In theif X2eNodeB
X2eNodeB
ServIP1, theServIP2,
FirstIPSecFlag MO. and
This parameter is must
The
MO,
ServIP3, be
SecIPSecFlag
SecSeGWFlag
value
if the different
andtheisare
of
not required if multi- FirstSeGWFlag
from
parameterFirstSigIP is setin
Valid IP address 0.0.0.0 X2eNodeB valid
FirstSigIP
ServIP4
set to
onlyparameters
FirstIPSecFlag
SecSeGWFlag ENABLE.
when isto
homing is not any
ENABLE other
SecIPSecFlag
parameters
parameter
valid
in and
only when
another isinsetthe
is to
the
supported.
DISABLE(Disable) X2eNodeB
SecSeGWFlag
The
set
ENABLEtoServIP1,
SecIPSecFlag
X2eNodeB ENABLE.
and MO.
MO
MO. the
is
DISABLE, ENABLE DISABLE(Disable) if IPSec is not X2eNodeB SecSigIP
parameter
ServIP2,
SecIKEIP
cannot
FirstSeGWFlag
set
In to ENABLE,
the in
X2eNodeBisisan
beServIP3,
the set
validsame to
that
supported X2eNodeB
DISABLE,
or
only
as ServIP4
parameter
is, the when the
FirstSigIP
MO, the ServIP1,to
actual isMO
both set
value in
must
SecIKEIP
parameter
DISABLE,
of be set
SecIPSecFlag
any MME
SecIPSecFlag
ServIP2,
ServIP1IKEIP intothe
MO.
the
ServIP3 a
and
is is
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2eNodeB value
parameter
X2eNodeB
SecSeGWFlag
The ServIP4 different
value must
of MO the from
be
are
FirstIKEIP
1.
and
valid only when
SecSigIP
set
cannotto a
FirstSigIP
parameter
SecIKEIP
parameters,
both be
ENABLE.in
valid the
is any
mustifIPsame
valid be
valid,
other
address.
as
set any
parameters
to
only when
must X2eNodeB
aof the
value
be unique
ServIP1IPSecFlag boththe
in
Valid IP address 0.0.0.0 None X2eNodeB
MO.
In the to
ServIP1,
X2eNodeB
different
SecIPSecFlag
among
is set X2eNodeB
ServIP2,
from
them.
ENABLE MO the
andIP
SecSigIP
MO,
ServIP3,
cannot
parameterif
SecSeGWFlag
The
and the
beand
ServIP1, inthe
inan same
any are
1024~65535 36422 36422 X2eNodeB X2eNodeB
SecIPSecFlag
ServIP4
None
as
DEVIP
set the SecSigIP
MO.
to ENABLE.
ServIP2,
ServIP1SeGWFlag MO in
parameters
ServIP3,
must
parameter
in
any
or
is MME
FirstIKEIPbe
another
ServIP1SeGWFlag
ServIP4
set toonlyset istothe
MO.
in
DISABLE. set a to
valid
value different when from
ENABLE
X2eNodeB
is valid
X2eNodeB
parameter
In only
the X2eNodeB and MO.
when
MO the
in the is
Valid IP address 0.0.0.0 None X2eNodeB ServIP1SecFlag
FirstSigIP in
SecSeGWFlag
In
SGW
MO,
set
theifMO
to
X2eNodeB
ServIP1IPSecFlag
cannot setany
be cannot
the
ENABLE. to
MME
parameter
MO,
is set
0.0.0.0.
be the MO.
the
to is as
ServIP1,
ENABLE,
same
ServIP1IPSecFlag setany to
DISABLE(Disable) ServIP1IKEIP
SecSigIP in an is
DISABLE,
ServIP2,
that
of the is,
parameter ServIP1, the
ServIP3
thewhen actual
is set to
DISABLE, ENABLE DISABLE(Disable) if IPSec is not X2eNodeB valid
X2eNodeB only MO
SecIKEIP
and
value
ServIP2,
ENABLE ServIP4
of ServIP3,
and the
supported both
must be setmust to a be
parameter
parameters,
ServIP1IPSecFlag
and ServIP4
ServIP1SeGWFlag if valid,
ServIP1SecFlag
value different from
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2eNodeB set
must
is 1.to
parameters
parameter bea value
unique in any
is set to
and
SecSigIP inthe any
different
among
ServIP1IKEIP
SGW
DISABLE, from
them.
MO. the
is IP
ServIP1SeGWFlag
MME MO.
parameter
The
valid ServIP1,
only in any
Valid IP address 0.0.0.0 None X2eNodeB
In
arethe
ServIP1IKEIP
set to when
X2eNodeB
ENABLE.
DEVIP
MO, theMO.
ServIP2,
both
parameter ServIP3,
ServIP1,
must be
SecIKEIP
or ServIP4
ServIP1IPSecFlag
ServIP2,
set to a valid in the
ServIP3 IP or
X2eNodeB
parameter
and
ServIP4
address.parameter, inMO the
Valid IP address 0.0.0.0 None X2eNodeB cannot be setbe to set
SGW the MO
ServIP1SeGWFlag
if valid,
In must
X2eNodeBcannot
0.0.0.0.
be
are the
to a set
MO, validsame
to IP
if the ENABLE. as any
of the
address. ServIP1,
ServIP1IPSecFlag
ServIP2,
In the X2eNodeB
parameter ServIP3,
is set to
and
MO, ServIP4
the
ENABLE and the SecSigIP,
parameters
ServIP1, ServIP2,
ServIP1SeGWFlag in any
SGW
parameter MO.
ServIP3 or is ServIP4
set to
In the X2eNodeB
parameter,
DISABLE, if valid,
the
ServIP1,
is set to ENABLE ServIP2,
ServIP3,
and and
ServIP4
ServIP2SeGWFlag parameters
in
is another
ServIP2IPSecFlag
set toonly
DISABLE.
The valid
ServIP1, when
X2eNodeB
is
In valid onlyMO.
the X2eNodeB when
ServIP2IPSecFlag
ServIP2, ServIP3,
In theif X2eNodeB
ServIP1IPSecFlag
MO, the
is set
or ServIP4to ENABLE.
MO,
is set the ServIP1,
to ENABLE,
ServIP2IPSecFlag
DISABLE(Disable) ServIP2IKEIP
parameter in is
the
ServIP2,
that
parameteris, theServIP3
actual
is
DISABLE, ENABLE DISABLE(Disable) if IPSec is not X2eNodeB valid
X2eNodeB
and
value
only
ServIP4
of and MO to
when set
supported ENABLE
both
cannot be theif the same
parameters,
ServIP2IPSecFlag
ServIP2SeGWFlag valid,
ServIP2SecFlag
as any of the
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2eNodeB must
is 1.
parameter be unique
is set
and
ServIP3IKEIP
ServIP1, ServIP2, is to
among
ServIP2IKEIP them.
ServIP3SeGWFlag
DISABLE,
ServIP2SeGWFlag
valid onlyand
ServIP3, whenis
the
The
valid
is ServIP1,
valid only
ServIP2IKEIP onlywhen whenis
Valid IP address 0.0.0.0 None X2eNodeB are
ServIP4set toparameters
ServIP3SecFlag ENABLE.
ServIP2,
both
ServIP3IPSecFlag
parameter ServIP3,
mustand be
set
in to ENABLE
another
ServIP3SeGWFlag
or
set ServIP4
ServIP2IPSecFlag
is set
to to ENABLE,
a valid IP
ServIP3SeGWFlag
X2eNodeB
is valid onlyin MO.
when
parameter
and
that
address. is, the the
actual
Valid IP address 0.0.0.0 None X2eNodeB is
In set
the to DISABLE.
X2eNodeB
ServIP3IPSecFlag
If the network does SGW
value
In the MO
ServIP2SeGWFlag
of cannot
X2eNodeB
In set
MO,
is anthe X2eNodeB
ServIP1,
tosame
not support IPSec, be
are the
set toENABLE,
ServIP3IPSecFlag
MO,
MO, if
if the as any
ENABLE.
ServIP2,
that
of the is, theServIP3
ServIP1,actual
DISABLE, ENABLE DISABLE(Disable) ServIP3IPSecFlag X2eNodeB is 1.
ServIP2IPSecFlag
ServIP3IPSecFlag
and ServIP4
value
ServIP2, of ServIP3,
should be set to ServIP3IKEIP
parameter
is set to ENABLE is to
is ifset
parameters,
ServIP3IPSecFlag
and ServIP4 valid,
DISABLE. valid
ENABLE
and only when
and the
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2eNodeB must
is 1. be unique
parameters in isany
both
ServIP4IKEIP
ServIP2SeGWFlag
ServIP3SeGWFlag
among
ServIP3IKEIP
ServIP4SeGWFlag
SGW them. is
MO.
ServIP3IPSecFlag
valid
parameter
is set only
toonly when
is set to
DISABLE,
The
valid
is
In ServIP1,
valid
the only when
X2eNodeB whenis
Valid IP address 0.0.0.0 0.0.0.0 X2eNodeB and
ServIP4SecFlag
DISABLE,
ServIP3IKEIP the must
ServIP2,
both
ServIP4IPSecFlag
MO, the ServIP3,
ServIP1,
ServIP3SeGWFlag
set to ENABLE
ServIP2IKEIP
be set to
ServIP4SeGWFlag a valid and
IP
or ServIP4
ServIP3IPSecFlag
is set
ServIP2, totoENABLE,
ServIP3
are set
ServIP4SeGWFlag
parameter
address.
is valid
parameter onlyENABLE.
must
in when
the beor
and
that
Valid IP address 0.0.0.0 None X2eNodeB ServIP4
is
set
In
SGW tois,X2eNodeB
set
an athe
to
ServIP4IPSecFlag
MO
actual
parameter,
DISABLE.
value
cannot
ServIP3SeGWFlag
value
ifInvalid, of must
anifX2eNodeB be set
different
MO,
is set fromas
tosame theany
IP
be
are the
set toENABLE,
ServIP4IPSecFlag
to
MO, a valid
if ENABLE.
IP
parameter
ServIP3IPSecFlag
that
of 1. is, the
the ServIP1, in any
actual
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) X2eNodeB is
address.
ServIP4IPSecFlag
DEVIP MO.
is
valueset to
ServIP2,
ServIP4IKEIP of ENABLE
ServIP3, is
In
is the to
set X2eNodeB
ENABLE
and
ServIP4IPSecFlag
and
valid ServIP4
only when
MO,
and the SecSigIP,
DISABLE, ENABLE DISABLE(Disable) None X2eNodeB ServIP3SeGWFlag
is 1.
parameters
both in any
ServIP1,
ServIP4SeGWFlag ServIP2,
is
SGW set to
ServIP4IKEIP MO.
ServIP4IPSecFlag DISABLE, is
ServIP3
is setonly or ServIP4
to DISABLE,
ServIP3IKEIP
valid
In
and the X2eNodeB when must
Valid IP address 0.0.0.0 0.0.0.0 X2eNodeB parameter,
ServIP4IKEIP if valid,
must
be
both
MO, set the to
ServIP4SeGWFlag a value
ServIP1,
must
be set be to set
a to a IP
valid
different
ServIP2,
are tofrom
ServIP4IPSecFlag ServIP3
setdifferentENABLE. IP inor
value
address. from
000~999 460 None X2eNodeB any
and
ServIP4
None DEVIP MO.
parameter,
the
In an X2eNodeB in
IP parameter
ServIP4SeGWFlag
ifany
valid,
DEVIP mustMO. be set
MO,
are if to ENABLE.
to a set valid IP
00~99,000~999 20 None X2eNodeB ServIP4IPSecFlag
None
address.
is set to ENABLE
In the X2eNodeB
and
MO, the SecSigIP,
0~1048575 None None X2eNodeB ServIP4SeGWFlag
None
ServIP1, ServIP2,
is
The setOperatorId
to DISABLE,
ServIP3 or ServIP4
ServIP4IKEIP
parameter in must
the
0~20 characters None None X2eNodeB parameter,
None if valid,
be set
X2eNodeB to a value
must be setMO to a
different
must be fromtoIP
set in
the
value different from
0~3 0 None X2eNodeB any
same DEVIP MO.
the IP value
parameter as thein
CnOperatorId
any DEVIP MO.
parameter in an
ESN, MAC, IP ESN(ESN) None CERTREQ None
existing CnOperator
MO.
0~32 characters None None CERTREQ None

0~0,2~2 None None CERTREQ None

0~64 characters None None CERTREQ None

0~64 characters None None CERTREQ None

0~128 characters None None CERTREQ None

0~128 characters None None CERTREQ None


DATA_ENCIPHER DATA_ENCIPHER DATA_ENCIPHER
MENT, MENT:1, MENT:1
DIGITAL_SIGNATU DIGITAL_SIGNATU DIGITAL_SIGNATU
RE, RE:1, RE:1
CERTREQ None
The CERTMK MO
KEY_AGREEMENT KEY_AGREEMENT KEY_AGREEMENT
, :1, :1 with APPCERT of
KEY_ENCIPHERM
SHA1, MD5 KEY_ENCIPHERM
SHA1(SHA1) KEY_ENCIPHERM
SHA1(SHA1) CERTREQ appcert.pem
None
ENT ENT:1 ENT:1 defines a certificate
configured on the
KEYSIZE1024, KEYSIZE2048(KEY KEYSIZE2048(KEY
CERTREQ None
eNodeB before
KEYSIZE2048 SIZE2048) SIZE2048)
delivery. There
must be one of this
0~128 characters None None CERTREQ None
MO in each
eNodeB and this
Valid IP address 0.0.0.0 None CERTREQ MO
None cannot be
added or removed.
The APPCERT
1~64 characters None None CERTMK parameter in the
CERTMK MO
cannot contain any
0~128 characters None None CERTMK None
of the following
characters:
0~128 characters None None CERTMK backslashes
None (\),
slashes (/), colons
The value of (*),
(:), asterisks the
0~128 characters None None CERTMK APPCERT
question
None marks (?),
parameter in an
double quotation
APPCERT
marks ("), leftMOangle
0~128 characters None None CERTMK None be the
must
brackets (<),same
right
as thatbrackets
angle of the (>),
APPCERT
and
Two pipes
APPCERT(|).
0~128 characters None None CERTMK None
parameter in a
MOs must be
configured
configured with
IKE, SSL None None APPCERT CERTMK
APPTYPEMO. of IKE in
The
one MOAPPCERT
and
parameter
APPTYPE in of the
SSL in
1~64 characters None None APPCERT APPCERT
the other. MO
cannot contain any
of the following
0~128 characters None None APPCERT None
characters:
backslashes (\),
0~128 characters None None APPCERT slashes
None (/), colons
(:), asterisks (*),
question marks (?),
0~128 characters None None APPCERT double
None quotation
marks ("), left angle
brackets (<), right
0~128 characters None None APPCERT None
angle brackets (>),
and pipes (|).
0~15 characters None None APPCERT None

0~128 characters None None APPCERT None


The CERTNAME
NORMALLY, parameter in the
ABNORMALITY, None None APPCERT None
CROSSCERT MO
FILENOTEXIST cannot contain any
IKE, SSL None None APPCERT of
Nonethe following
characters:
backslashes (\),
1~64 characters None None CROSSCERT slashes (/), colons
(:), asterisks (*),
question marks (?),
0~128 characters None None CROSSCERT None
double quotation
marks ("), left angle
brackets (<), right
angle brackets (>),
and pipes (|).
0~128 characters None None CROSSCERT None

0~128 characters None None CROSSCERT None


One and only one
TRUSTCERT MO
0~128 characters None None CROSSCERT NoneCERTNAME of
with
caroot.pem must be
NORMALLY, configured for each
ABNORMALITY, None None CROSSCERT None
eNodeB.
FILENOTEXIST The CERTNAME
0~128 characters None None CROSSCERT parameter
None in the
TRUSTCERT MO
cannot contain any
1~64 characters None None TRUSTCERT of the following
characters:
backslashes (\),
0~128 characters None None TRUSTCERT None
slashes (/), colons
(:), asterisks (*),
0~128 characters None None TRUSTCERT question
None marks (?),
double quotation
marks ("), left angle
0~128 characters None None TRUSTCERT brackets
None (<), right
angle brackets (>),
and pipes (|).
0~128 characters None None TRUSTCERT None
The CERTNAME
NORMALLY, parameter in the
ABNORMALITY, None None TRUSTCERT None
CRL MO cannot
FILENOTEXIST contain any of the
0~128 characters None None TRUSTCERT following
None
characters:
backslashes (\),
1~64 characters None None CRL slashes (/), colons
NORMAL, (:), asterisks (*),
CERTLOSS, question marks (?),
CERTDAMAGE, None None CRL None
double quotation
UNKNOWFORMAT, marks ("), left angle
FAILED brackets (<), right
0~128 characters None None CRL None
angle brackets (>),
and pipes (|).
0~128 characters None None CRL None

0~128 characters None None CRL None

Valid IP address None None CRLTSK None


DSTF in the
CRLTSK MO must
0~255 characters None None CRLTSK None
be set to a value
different from DSTF
in any other
0~255 characters None None CRLTSK None
This
CRLTSKparameter
MO. is
validFILENAME
The only when
CRLGETMETHOD
parameter in the
0~65535 21 21 CRLTSK
in the same
CRLTSK MO
CRLTSK MO is any
cannot contain set
1~64 characters None None CRLTSK to LDAP.
of the following
characters:
backslashes (\),
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) CRLTSK None
slashes (/), colons
(:), asterisks (*),
question marks (?),
double quotation
marks ("), left angle
brackets (<), right
angle brackets (>),
and pipes (|).
8~240 24 24 CRLTSK None

0~3 None None CRLTSK None

FTP, LDAP FTP(FTP) FTP(FTP) CRLTSK None


This parameter is
valid only when
CRLGETMETHOD
0~255 characters None None CRLTSK
in the same
CRLTSK MO is set
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) CERTCHKTSK to LDAP.
None

1~15 7 7 CERTCHKTSK None

7~180 30 30 CERTCHKTSK None

PROXY, CMP PROXY(PROXY) PROXY(PROXY) CERTCHKTSK None


NOVERIFY,
NOVERIFY(No NOVERIFY(No
ALARM, CRLPOLICY None
Verifying) Verifying)
DISCONNECT
20000~60000 20000 20000 GTPU None

3~6 3 3 GTPU None

0~63 0 0 GTPU None

3000~3999 None None ACL None

0~127 characters None None ACL None

3000~3999 None None ACLRULE None

1~65535 None None ACLRULE None

DENY, PERMIT PERMIT(Permit) PERMIT(Permit) ACLRULE None

IP, ICMP, TCP,


None None ACLRULE None
UDP, SCTP
In the ACLRULE
Valid IP address None None ACLRULE MO,
Noneif SOP is set to
OP_LT, the value of
this parameter must
valid wildcard of the
None None ACLRULE None
be larger than or
IP address In the ACLRULE
equal to 0.
MO,
In thethis parameter
ACLRULE
NO, YES None None ACLRULE is
MO,valid only
if ACLRULE
SOP is when
set to
In
PT the
is set to TCP,
OP_LT, OP_GT, OP_GT,
MO, the
thisSCTP. value
parameter
UDP,
of thisorparameter
OP_EQ, OP_NEQ, None None ACLRULE is valid only when
OP_RANGE must
SMPTbe is less than
set to
or equal
YES. to 65535.
0~65535 None None ACLRULE In the ACLRULE
MO, if SOP is set to
OP_RANGE, the
value of this
parameter must be
smaller than or
equal to that of
SPT2.
In the ACLRULE
In the ACLRULE
MO, if SOP is set to
OP_RANGE, the
value of this
parameter must be
larger than or equal
0~65535 None None ACLRULE to that of SPT1.
In the ACLRULE
MO,
In thethis parameter
ACLRULE
Valid IP address None None ACLRULE None
is valid only when
MO, if DOP is set to
SMPT
OP_RANGE, is set tothis YES
valid wildcard of the and SOP is
None None ACLRULE None
parameter musttobe
set
IP address OP_RANGE.
In the ACLRULE
smaller than or
MO,
equalthis to parameter
DPT2.
NO, YES None None ACLRULE is
In
In valid
the
the only when
ACLRULE
ACLRULE
In
PT
MO, the ACLRULE
isififset
DOP to TCP,
is set
set to
to
OP_LT, OP_GT, MO,
MO, this DOP is
parameter
UDP,
OP_RANGE,
OP_LT, or SCTP.
the the of
value
OP_EQ, OP_NEQ, None None ACLRULE is validofonly
value this when
OP_RANGE this
DMPT parameter
is set to must
parameter
be larger must
than orbe
YES.
larger than or equal
0~65535 None None ACLRULE equal to 0.
to
In that of DPT1.
the ACLRULE
In
MO, theif ACLRULE
DOP is set to
0~65535 None None ACLRULE MO,
OP_GT, this the parameter
value
is valid only
of this parameter when
DOP
must is set to than
NO, YES NO(No) NO(No) ACLRULE In
Nonethebe less
ACLRULE
OP_RANGE.
or equal
In thethis to
ACLRULE 65,535.
MO, parameter
In
In
MO, the
thethis ACLRULE
ACLRULE
parameter
is valid only when
MO,
MO, this parameter
0~63 None None ACLRULE PT is set parameter
is this
valid only
to awhenvalid
is
is valid
valid only
MDSCP only
is set when
whento
value.
DOP
DMPT
YES. isisset settoto
In an ACLRULE
NO, YES NO(No) NO(No) ACLRULE OP_RANGE.
YES.
MO,
SRCIP MFRG in theand
SMPT
BFDSESSIONbe cannot MO
0~7 0 0 BFDSESSION both
must set
None be setto YES;to a in
addition,
valid IP address MFRG of
and
DSTIP DMPT
Class A, B, in cannot
theor C. In
0~1 0 0 BFDSESSION None
be both
BFDSESSION set to YES.
MO
addition, it cannot
must be set
be set to 127.x.x.x to a
valid
or IP address of
0.x.x.x.
6~7 None None BFDSESSION None
Class
In the A, B, or C. In
In the
addition,
BFDSESSION
BFDSESSION it cannot MO,
MO,
0~95 None None BFDSESSION be set
this parameter
SRCIP to
must127.x.x.x
beis
or 0.x.x.x.
valid
different onlyfrom when SN
SRCIP
DSTIP. orDSTIP
is set to and
6 7.
Valid IP address None None BFDSESSION in a BFDSESSION
SRCIP in the
MO must be MO
BFDSESSION
different.
In
to the
be added must
Valid IP address None None BFDSESSION
DSTIP
BFDSESSION
have been in a MO,
ifBFDSESSION
SRCIP
configured. is set
That MO
to a
is,
SINGLE_HOP, must beIPdifferent
None None BFDSESSION logical
a DEVIP address,
MO must
MULTI_HOP from SRCIP
this been and
haveparameter
DSTIP
cannot
configured in
beother
set
withtoIP
10~1000 100 100 BFDSESSION None
BFDSESSION
SINGLE_HOP.
set to the same
MOs.
value as that of
DSTIP
SRCIP in the
10~1000 100 100 BFDSESSION None in the
BFDSESSION
BFDSESSION MO MO
must
to be be different
added.
3~10 3 3 BFDSESSION from
Noneany IP address
in the system.
MAINTENANCE, RELIABILITY(Relia RELIABILITY(Relia
BFDSESSION None
RELIABILITY bility) bility)

0~63 0 0 BFDSESSION None

NO, YES NO(No) NO(No) BFDSESSION None


ADMINDOWN,
None None BFDSESSION None
DOWN, INIT, UP
DEMAND_MODE,
ASYNCHRONOUS None None BFDSESSION None
_MODE
10~1000 None None BFDSESSION None

10~1000 None None BFDSESSION None

0~4294967295 None None BFDSESSION None

0~4294967295 None None BFDSESSION None

0~4294967295 None None BFDSESSION None

NO_DIAGNOSTIC,
0~4294967295 None None BFDSESSION None
CTRL_DECT_TIME
_EXPIRED, In the CFMBNDIP
ECHO_FUNC_FAIL
0~4294967295 None None BFDSESSION None
MO, the total length
ED, of MANAME and
NEIGHBOR_SIG_S MDNAME cannot
0~4294967295
ESSION_DOWN, None None BFDSESSION None
exceed 44 bytes.
FORDWARDING_P MANAME and
LANE_RESET, This
MDNAME parameter to be
None None BFDSESSION None
PATH_DOWN, cannot
referenced containin thethe
CONCATENATED_ following
CFMBNDIP illegal
MO
PATH_DOWN,
0~15 None None BFDSESSION characters:
None already
must single
exist.
ADMIN_DOWN, Digits 0 to 9 and quotation
MDNAME in the('),
mark
REVERSE_CONCA letters a to z and A double
CFMBNDIP quotation
1~43 characters
TENTATED_PATH_ None CFMBNDIP MDNAME inMOthe
to Z are mark ("),
cannot contain the
DOWN, CFMMA MO cannot
Digits 0 to 9 and
recommended. exclamation
following mark
illegal
PEER_ADMIN_DO contain the
letters a to z and A (!), question mark
characters:
1~43 characters
WN
None CFMBNDIP following single
to Z are (?), left angle
quotation mark ('),
characters: single
recommended. bracket
In
doubleCFMMA
the (<), right
quotation MO,
quotation
IP intotal
the mark ('),
1~8191 None None CFMBNDIP angle
None
the
mark bracket
("), length(>) of
Letters, numbers, double
CFMBNDIP quotationMO(\).
and
MANAME backslash
and characters mark
must ("), anand
exclamation
be
mark
IP
In
(!),the
MDNAME CFMBNDIP
question cannot
mark
Valid IP address None excluding
None 0 to such CFMBNDIP exclamation
address markA,
of bytes.
Class
Digits 9 and MO,
exceed
(?), theangle
left 44total length
invalid (!),or
question mark
letters acharacters
to z and A B,
of
MDNAME
bracket
C.
MANAME In addition,
in and
the
(<), right
as (?), left angle
to Zsingle
are quotation itCFMMA
cannot
MDNAME
angle
becannot
MO
bracket
set to
cannot
(>)
1~43 characters None mark ('), doublefor CFMMA bracket
127.x.x.x (<),or right
0.x.x.x.
recommended exceed
contain
and 44 bytes.
the (>),
quotation markvalue
("), anglebackslash
bracket (\).
the MDNAME following
exclamation mark and backslash (\).
1~43 characters None of a CFM MA. CFMMA characters: single
(!), question mark In the CFMMA MO,
quotation
the total lengthmark of ('),
(?), is less than (<),
double
MANAME quotation
and
0~7 0 is
0 more than (>), CFMMA None
mark
MDNAME ("), cannot
and backslash (\)
exclamation
exceed 44 bytes. mark
are recommended
0~1 0 0 the MANAME CFMMA (!),
None question
Before mark
configuring
for
(?), left angle
a CFMMA MO,
value of the CFM
bracket
MDNAME (<),must
right
MA.
6~7 None None CFMMA angle
already exist. (>),
None bracket
VLANID
and backslash in each(\).
CFMMA MO whose
NO, YES YES(Yes) YES(Yes) CFMMA None
BNDVLAN is set to
YES must be
unique.
1~4094 1 None CFMMA
In the CFMMA MO,
this parameter is
valid only when
BNDVLAN is set to
YES.
In the CFMMA MO,
VLANPRI is valid
only when
BNDVLAN in the
MO is set to YES. If
BNDVLAN is set to
0~7 0 0 CFMMA NO, VLANPRI
cannot be modified.
10ms, 100ms, 1s, In the CFMMA MO,
1s(1s) 1s(1s) CFMMA None
this parameter is
10s, 1min, 10min
valid only when
0~32 None None CFMMA BNDVLAN
None is set to
YES.
MDNAME in the
0~64 None None CFMMA None
CFMMD MO must
be unique in the
0~4294967295 None None CFMMA BS.
None
MDNAME in the
CFMMD MO cannot
0~4294967295 None None CFMMA The
NoneBS the
contain supports a
maximum
following of eight
CFM MDs. LEVEL
characters: single
1~43 characters None None CFMMD in the CFMMD
quotation mark MO ('),
must
The
In bequotation
value
a CFMMEP
double setofto MO,
a
value
MDNAME
the
mark in the
total
("), inrange
length theof
0~7 0 0 CFMMD
of 0
CFMMEP
MANAME to
exclamation7, where
MO
and mark the
value
cannot
MDNAME 7 indicates
contain
cannot
(!), question mark the
0~4294967295 None None CFMMD the
(?), highest
following
None
exceedleft angle MD
44invalid
bytes.
level
MANAME
bracket and(<),
characters: the
and value
single
right
0 indicates
quotation
MDNAME
angle bracket the
mark
to be ('),
(>),
None None None 0 to 9 and
Digits CFMMD None
lowest
double
referenced MD level.
quotation
in a(\).
and backslash
letters a to z and A mark ("), MO must
CFMMEP
to Z are exclamation
already exist.mark
1~43 characters None Digits 0 to 9 and CFMMEP
recommended for (!), question
The value of mark
letters a to z and
the MDNAME A
value (?), left angle
MANAME in the
to Z are
of a CFM MEP. bracket (<), right
1~43 characters None CFMMEP CFMMEP MO
recommended for angle
the MANAME value MEPID in the (>),
cannot bracket
contain the
and backslash
following
CFMMEP MO must invalid (\).
1~8191 None of a CFM MEP.
None CFMMEP In
bethe
characters:
uniqueCFMMEPinsingle
the
MO, the
quotation
CFM MA.total
mark length
('),
of MANAME
double quotationand
0~7 0 0 CFMMEP None
MDNAME
mark ("), cannot
exceed 44 bytes.
exclamation mark
0~1 0 0 CFMMEP (!),
None question mark
(?), left angle
bracket (<), right
6~7 None None CFMMEP None bracket (>),
angle
In the CFMMEP
and
MO, backslash
if SN is set(\). to 6
BASE_BOARD None None CFMMEP or 7, this parameter
In thebe
must CFMMEP
set to
MO, this
BASE_BOARD.parameter
ETH, ETHTRK None None CFMMEP is valid only when
In
SBTtheisCFMMEP
set to a valid
MO,
value.this parameter
0~1 None None CFMMEP is valid only when
PT is set to a valid
value.
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) CFMMEP None

NO, YES YES(Yes) YES(Yes) CFMMEP None

1~4094 None None CFMMEP None

0~7 0 0 CFMMEP None


0~4294967295 None None CFMMEP None

0~4294967295 None None CFMMEP None

0~4294967295 None None CFMMEP None

0~4294967295 None None CFMMEP None

0~4294967295 None None CFMMEP None

0~4294967295 None None CFMMEP None

In the CFMRMEP
0~4294967295 None None CFMMEP None
MO, the total length
of MANAME and
MDNAME cannot
0~4294967295 None None CFMMEP None
exceed 44 bytes.
MANAME in
MANAME andthe
0~4294967295 None None CFMMEP MDNAME
None
CFMRMEP toMObe
referenced
cannot in the
contain the
CFMRMEP
following invalidMO
0~4294967295 None None 0 to 9 and
Digits CFMMEP None
must already
characters: exist.
single
letters a to z and A MDNAMEmark
quotation in the
to Z are CFMRMEP
('),double MO
quotation
1~43 characters None Digits 0 to 9 and CFMRMEP MAC in the
recommended for cannot
mark contain the
("),
letters a to z and A CFMRMEP MO
the MDNAME value following
exclamation invalid
to Z are cannot be setmark to all
1~43 characters None of a CFM RMEP. CFMRMEP characters:
(!), question single
mark
recommended for Fs or a multicast
quotation
(?),
MEPID mark
left angle
inThe
the format
the MANAME value address.
('),double
bracket
CFMRMEP quotation
(<), right
MO
1~8191 None of a CFM RMEP.
None CFMRMEP of a MAC address
mark
angle
must ("),
bracket
be unique (>),
in
is XXXX-XXXX-
exclamation
and
the backslash
CFM MA. mark
(\).
XXXX. A broadcast
(!), question
MANAME andmark
14 characters 0000-0000-0000 None CFMRMEP MAC address is
(?), left angle
MDNAME to be A
FFFF-FFFF-FFFF.
bracket (<),inright
referenced
multicast MACthe
NORMAL, FAULT None None CFMRMEP angle
CFMRMEP
None bracket MO (>),
address is 0100-
and
must backslash
already (\).
exist.
5EXX-XXXX or one
14 characters None None CFMRMEP that
Noneis within the
range from 80XX-
XXXX-XXXX to
NO, YES NO(No) NO(No) CFMRMEP FFXX-XXXX-XXXX.
None

0~4294967295 None None CFMRMEP None

0~4294967295 None None CFMRMEP None

0~4 None None CFMRMEP None


In the DBGSVR
MO, if
SERVICETYPE is
Valid IP address None None CFMRMEP None
set to TCP, this
parameter can be
TCP,23,
UDP set to 22, 23, 1110,
22, 67, 68, 319, None None DBGSVR None
1120, 2700, 4443,
320, 500, 1110,
or 30023.
1120, 2700, 3784,
None None DBGSVR In the DBGSVR
4443, 4500, 4784,
MO, if
17185, 30023,
SERVICETYPE is
33003, 45300
set to UDP, this
parameter can be
set to 67, 68, 319,
320, 500, 3784,
4500, 4784, 17185,
33003, or 45300.
SBT is set to
E1_COVERBOARD
, and PT is set to
PPP, the value
range of this
parameter is from 0
to 15.
DISABLE, ENABLE None None DBGSVR In
None the DEVIP MO, if
SN is within the
range from 0 to 5,
0~7 0 0 DEVIP SBT
Noneis set to
E1_COVERBOARD
, and PT is set to
0~1 0 0 DEVIP In
None
MPGRP, the DEVIP the value MO, if
SN
range is within the
of this MO, if
In
range the DEVIPfromis0 from to 5, 0
parameter
SBT is set to must
0~7 None None DEVIP None
this parameter
to 3. in the DEVIP
BASE_BOARD,
MASK this
be
In set DEVIP
the to MO, if
IP
parameter
MO incannot
the DEVIP can
be beMO
set
BASE_BOARD, E1_COVERBOARD
SN is within the
None None DEVIP must
set
to be
allto0s. ETH, set to a
E1_COVERBOARD .range from
valid
ETHTRK,
In
In the
the
IPDEVIP
DEVIP or0 to
address MO, 5,
of
MO, ifif
PPP, MPGRP, ETH, SBT
Class
LOOPINT.
PT is isnot
A,setB, toorto
set C. In
None None DEVIP SN is set to 6 or 7,
E1_COVERBOARD
ETHTRK, LOOPINT addition,
In
LOOPINT,the DEVIPit MASK
cannotMO, if
this
,cannotand parameter
PT issetset must
be
SBT 127.x.x.x
is set
be to ortotoall
be
LOOPINT, set to the value
0~15 None None DEVIP 0.x.x.x.
E1_COVERBOARD
1s.
BASE_BOARD.
,range
In this of this value
theparameter
DEVIP
binary MO, can
parameter
the
be set
into Network
whichto PPP, is ID
MASK from 0
of in
Valid IP address None None DEVIP to
the
MPGRP,
the 3. logic AND
DEVIP orMOresult is
In
of theand
IP
LOOPINT.
converted, DEVIP 0 isMO,
MASK not if
SN
cannot
allowed is set betotoall 60s
precedeor or7,
Valid Mask address None None DEVIP SBT
all 1s. is set to
1.
BASE_BOARD,
In the
In the DEVIPDEVIP MO,
DISABLE(DISABLE DHCPRELAYSWIT IP and inPT theis set MO, to
DISABLE, ENABLE ENABLE(ENABLE) the
the
None Host
Network ID of ID the
of
) CH DHCPSVRIP
ETH, this MO
parameter
logic
the AND
logic ANDresult of
result
must
can bebeset settoto0aor 1.
IP
of and
IP and MASKMASK of
valid
In theIPDEVIP address MO,
Valid IP address None None DHCPSVRIP cannot
cannot be
be all
all 0s0s orif
Class
SN A, B,
is set to or 6 orC.or In
7,
all 1s.
all 1s.
addition,
SBT is setit to
cannot
In
be
In the DEVIP
127.x.x.x
the DIFPRI orMO,
MO,
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) DHCPSW None
In the
BASE_BOARD, DIFPRI MO,
the
0.x.x.x.
the Host
value ID
rangeof theof
OMHIGHPRI
and
logic PT
AND is set
result must
to of
IPPRECEDENCE, this
be
ETHTRK, parameter
larger than
this is
or
DSCP(DSCP) DSCP(DSCP) DIFPRI IP
None and
from 0toto 63can MASK if be
DSCP equal
parameter
cannot be is allset0s toor
PRIRULE
OMLOWPRI.
set to 0 or 1.
all
DSCP. 1s.
0~63 46 46 DIFPRI In the
In the DIFPRI
DIFPRI
DEVIP MO, MO,if
MO,
In
ififSNthe
PRIRULE DIFPRI
is set
PRIRULE to is is
6 orMO,
set7,to
set to
the
DSCP,
SBT is set
DSCP, value the range
the to valueof
value
0~63 46 46 DIFPRI this
In
range the
BASE_BOARD,
range parameter
DIFPRI
of this MO,
of this is
from
ifparameter
and 0 tois7set
PRIRULE
parameter PT ifisfrom
is
is set to
from
to 0
0
PRIRULE
DSCP,
to 63. theis
LOOPINT,
to 63. setvalue
value
the to
0~63 14 14 DIFPRI In the DIFPRI
IPPRECEDENCE.
range of MO,
In
range
In the of this
the DIFPRI
DIFPRI
this MO, MO,
ifparameter
PRIRULE is set to
PRIRULEis
ifparameter isisfrom
set to
from 0
0
DSCP,
to 63. the value
0~63 46 46 DIFPRI IPPRECEDENCE,
to 3.
range
In the of this MO,
DIFPRI
the
parameter value range
isisfrom of 0
ifthisPRIRULE
parameter set
is to
to 63.
IPPRECEDENCE,
0~63 46 46 DIFPRI from 0DIFPRI
to 7. MO,
In
thethe value range of
ifthisPRIRULE
parameter is set
is to
HQ, LQ HQ(High Quality) HQ(High Quality) DIFPRI IPPRECEDENCE,
None0 to 7.
from
the value range of
this parameter is
0~100 100 100 DIFPRI In
None
from the0DIFPRIto 7. MO,
if PRIRULE is set to
DSCP, the value
0~1000 0 0 DIFPRI None
range of this
parameter is from 0
to 63.
0~63 26 26 DIFPRI
In the DIFPRI MO,
if PRIRULE is set to
HQ, LQ HQ(High Quality) HQ(High Quality) DIFPRI IPPRECEDENCE,
None
the value range of
this parameter is
from 0 to 7.
0~100 100 100 DIFPRI In the DIFPRI MO,
None
if PRIRULE is set to
DSCP, the value
0~1000 0 0 DIFPRI None of this
range
parameter is from 0
to 63.
0~63 34 34 DIFPRI
In the DIFPRI MO,
if PRIRULE is set to
HQ, LQ HQ(High Quality) HQ(High Quality) DIFPRI IPPRECEDENCE,
None
the value range of
this parameter is
0~100 100 100 DIFPRI In the0DIFPRI
None
from to 7. MO,
if PRIRULE is set to
DSCP, the value
0~1000 0 0 DIFPRI None of this
range
parameter is from 0
to 63.
0~63 26 26 DIFPRI
In the DIFPRI MO,
if PRIRULE is set to
HQ, LQ HQ(High Quality) HQ(High Quality) DIFPRI IPPRECEDENCE,
None
the value range of
this parameter is
0~100 100 100 DIFPRI In the0DIFPRI
None
from to 7. MO,
if PRIRULE is set to
DSCP, the value
0~1000 0 0 DIFPRI None of this
range
parameter is from 0
to 63.
0~63 46 46 DIFPRI
In the DIFPRI MO,
if PRIRULE is set to
HQ, LQ HQ(High Quality) HQ(High Quality) DIFPRI IPPRECEDENCE,
None
the value range of
this parameter is
0~100 100 100 DIFPRI In the0DIFPRI
None
from to 7. MO,
if PRIRULE is set to
DSCP, the value
0~1000 0 0 DIFPRI None of this
range
parameter is from 0
to 63.
0~63 18 18 DIFPRI
In the DIFPRI MO,
if PRIRULE is set to
HQ, LQ LQ(Low Quality) LQ(Low Quality) DIFPRI IPPRECEDENCE,
None
the value range of
this parameter is
0~100 30 30 DIFPRI In the0DIFPRI
None
from to 7. MO,
if PRIRULE is set to
DSCP, the value
0~1000 100 100 DIFPRI None of this
range
parameter is from 0
to 63.
0~63 18 18 DIFPRI
In the DIFPRI MO,
if PRIRULE is set to
HQ, LQ LQ(Low Quality) LQ(Low Quality) DIFPRI IPPRECEDENCE,
None
the value range of
this parameter is
0~100 30 30 DIFPRI In the0DIFPRI
None
from to 7. MO,
if PRIRULE is set to
DSCP, the value
0~1000 100 100 DIFPRI None of this
range
parameter is from 0
to 63.
0~63 10 10 DIFPRI
In the DIFPRI MO,
if PRIRULE is set to
IPPRECEDENCE,
the value range of
this parameter is
from 0 to 7.
HQ, LQ LQ(Low Quality) LQ(Low Quality) DIFPRI None

0~100 30 30 DIFPRI In the DIFPRI MO,


None
if PRIRULE is set to
DSCP, the value
0~1000 100 100 DIFPRI None
range of this
parameter is from 0
to 63.
0~63 0 0 DIFPRI
In the DIFPRI MO,
if PRIRULE is set to
HQ, LQ LQ(Low Quality) LQ(Low Quality) DIFPRI IPPRECEDENCE,
None
the value range of
this parameter is
0~100 30 30 DIFPRI None0 to 7.
from

0~1000 100 100 DIFPRI None

OFF, ON ON(On) ON(On) DLITFCALG None

OFF, ON ON(On) ON(On) DLITFCALG None

0~7 0 0 E1T1 In
Nonethe E1T1 MO, if
PS is set to
ALLPORT and
0~1 0 0 E1T1 WORKMODE
None is set
to E1_UNBA or
E1_BA, FRAME
0~5 None None E1T1 None
can be set to
In the E1T1 MO,
E1_DOUBLE_FRA
this parameter is
ME or
0~7 255 None E1T1 valid only when PS
E1_CRC4_MULTI_
In the to
E1T1 MO, if
is set
FRAME.
PS is set to
ALLPORT, SINGLEPORT.
ALLPORT(All Ports) ALLPORT(All Ports) E1T1 In
Nonethe E1T1and
ALLPORT MO, if
E1_DOUBLE_FRA
SINGLEPORT PS is
WORKMODEset to
In the E1T1 MO, is set
ME,
E1_UNBA, E1_BA, E1_UNBA(E1 E1_UNBA(E1 ALLPORT
to
thisE1_UNBA and
parameter oris
E1_CRC4_MULTI_ E1T1
T1, UNKNOWN Unbalance) Unbalance) WORKMODE
E1_BA, whenisPS
valid onlyLNCODE set
FRAME,
to
can T1,
is set FRAME
betoset canor
to AMI
ALLPORT.
T1_SUPER_FRAM E1_CRC4_MULTI_
be
HDB3.set to
E, None FRAME(E1 CRC4 E1T1
If an E1/T1 port is T1_SUPER_FRAM
In the E1T1 MO, if
T1_EXTENDED_S Multiple Frames)
carried over IP, the E orand
PS
UPER_FRAME,
HDB3, AMI, B8ZS,
None AMI line coding E1T1 T1_EXTENDED_S
WORKMODE are
E1_MODIFY_CRC4
UNKNOWN
mode is not UPER_FRAME.
set to ALLPORT
_MULTIFRAME,
OK, LOCAL_LOOP,
SLAVE(Slave recommended.
SLAVE(Slave In
and the
T1E1T1 MO, if
respectively,
UNKNOWN
REMOTE_LOOP,
MASTER, SLAVE E1T1 None
Mode) Mode) PS is set to
LNCODE can be
PAYLOAD_LOOP,
SINGLEPORT,
set to AMI or B8ZS.
SINGLE_CH_LOOP
FRAME
In can be set
,EXECUTELINKTES
LOS, AIS, LFA, None None E1T1 None E1T1 MO, if
the
to
PS is set to
RA, LMFA, SLIP,
TFlAG_0, E1_DOUBLE_FRA
SINGLEPORT,
OTHERS,
EXECUTELINKTES
None None E1T1 ME,
LNCODE
None can be
BACKUP,
TFlAG_1, E1_CRC4_MULTI_
set to HDB3, AMI,
PHYSICAL_LOOP
EXECUTELINKTES FRAME,
or B8ZS.
TFlAG_2
NO, YES None None E1T1 None
T1_SUPER_FRAM
E, or
T1_EXTENDED_S
0~720 None None E1T1 None
UPER_FRAME.
In the E1T1 MO,
this parameter is
E1_COVERBOARD None None E1T1 valid only when SN
is within the range
from 0 to 5.
1E-3, 1E-4, 1E-5,
1E-5(1E-5) 1E-5(1E-5) E1T1BER None
1E-6

0~7 0 0 ETHOAM3AH None

0~1 0 0 ETHOAM3AH None

6~7 None None ETHOAM3AH None


In the
ETHOAM3AH MO,
BASE_BOARD None None ETHOAM3AH this parameter is
valid only when SN
is
In set
the to 6 or 7.
ETH None None ETHOAM3AH None
ETHOAM3AH MO,
this parameter is
0~1 None None ETHOAM3AH valid only when SN
is set to 6 or 7 and
ACTIVE(Active ACTIVE(Active SBT is set to
PASSIVE, ACTIVE ETHOAM3AH None
BASE_BOARD.
Mode) Mode)
10,20,50,100,200,5
1000 1000 ETHOAM3AH None
00,1000

64~1518 128 128 ETHOAM3AH None

DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) ETHOAM3AH None

DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) ETHOAM3AH None

1~60 1 1 ETHOAM3AH None

1~65535 1 1 ETHOAM3AH In the


None
ETHOAM3AH MO,
ERRFRMSCDEVT
10~900 60 60 ETHOAM3AH In
PRDthemust be larger
OAM3AH_SESSIO ETHOAM3AH
than or equal toMO,
N_IDLE, ERRFRMSCDEVTT
ERRFRMSCDEVTT
1~900
OAM3AH_SESSIO 1 1 ETHOAM3AH HD
HD.must be smaller
N_DISCOVER, than or equal to
OAM3AH_SESSIO ERRFRMSCDEVT
None None ETHOAM3AH None
PRD.
N_DETECT,
OAM3AH_SESSIO
N_LB_LOCAL,
0~4294967295 None None ETHOAM3AH None
OAM3AH_SESSIO
N_LB_REMOTE
0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None


0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None

0~4294967295 None None ETHOAM3AH None

0~7 0 0 ETHPORT None

0~1 0 0 ETHPORT None


In the ETHPORT
MO, PN cannot
6~7 None None ETHPORT exceed
None the actual
In the ETHPORT
number
In the of Ethernet
ETHPORT
MO, if PA is set to
ports
MO, on the board.
BASE_BOARD None None ETHPORT COPPER,parameter
this SPEED
In
is the
valid ETHPORT
onlytowhen
If an optical fiber is can
MO, beSBTset 10M,to
used for SN isifset
100M, to is6 set
or AUTO. or 7.
In
BASE_BOARD, this
0~1 None None
transmission, set ETHPORT the
In ETHPORT
the ETHPORT MO,
parameter can be
this parameter to ifMO,
PA is setistoset to
set toif 0PAor 1.
COPPER, FIBER, FIBER. FIBER, SPEED can
None ETHPORT In the ETHPORT
AUTO If an electrical cable be set to 100M,
MO, if SBT is set to
is used for 1000M, or AUTO.
ETH_COVERBOAR
46~1800 1500 transmission,
1500 set ETHPORT In
Nonethe ETHPORT
D, the value range
this parameter to MO, ifthisPAparameter
is set to
of this parameter is
COPPER. COPPER,
is this
10M, 100M, 1000M, AUTO(Automatic AUTO(Automatic from 0 to 3. SN is
valid when
ETHPORT parameter
set to 6 or 7can andbe
AUTO, UNKNOWN Negotiation) Negotiation)
set
SBTtois10M,
set to100M,
AUTO(Automatic or AUTO.
BASE_BOARD.
FULL, AUTO FULL(Full Duplex) ETHPORT None
In the ETHPORT
Negotiation)
MO, if PA is set to
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) ETHPORT FIBER,
None this
parameter can be
set to 100M,
CLOSE, OPEN OPEN(Open) OPEN(Open) ETHPORT 1000M,
None or AUTO.
In the
In the ETHPORT
ETHPORT
MO, FERDT
MO, if PA is set to
must
0~100 10 10 ETHPORT AUTO, thisthan or
be smaller
In the to
parameter
equal ETHPORTmust be
FERAT.
MO,
set toFERDT
AUTO. must
0~100 8 8 ETHPORT
be smaller than or
equal to FERAT.
14 characters None None ETHPORT None

UP, DOWN None None ETHPORT None


NOLOOP,
REMOTE, LOCAL, None None ETHPORT None
UNKNOWN
NO, YES None None ETHPORT None
DISABLE, ENABLE None None ETHPORT None

0~4294967295 None None ETHPORT None

0~4294967295 None None ETHPORT None

0~4294967295 None None ETHPORT None

0~4294967295 None None ETHPORT None

0~4294967295 None None ETHPORT None

0~4294967295 None None ETHPORT None

0~10 None None ETHPORT None

0~4294967295 None None ETHPORT None

Valid IP address None None ETHPORT None

FORCE, AUTO None None ETHPORT None

FORCE, AUTO None None ETHPORT None

10M, 100M, 1000M,


None None ETHPORT None
AUTO

HALF, FULL, AUTO None None ETHPORT None

FORCE, AUTO,
None None ETHPORT None
UNKNOWN
10M, 100M, 1000M,
None None ETHPORT None
AUTO, UNKNOWN
HALF, FULL,
None None ETHPORT None
AUTO, UNKNOWN

0~7 0 0 ETHTRK None

0~1 0 0 ETHTRK None

6~7 None None ETHTRK None

0~1 0 0 ETHTRK None

ENABLE(Enable ENABLE(Enable
DISABLE, ENABLE ETHTRK None
LACP) LACP)

DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) ETHTRK None


In the ETHTRK MO,
this parameter is
BASE_BOARD None None ETHTRK
valid only when SN
is set to 6 or 7.
46~1800 1500 1500 ETHTRK None

UP, DOWN None None ETHTRK None

14 characters None None ETHTRK None

14 characters None None ETHTRK None

0~2 None None ETHTRK None

0~7 characters None None ETHTRK None

0~2 None None ETHTRK None

0~7 characters None None ETHTRK None

0~4294967295 None None ETHTRK None

0~4294967295 None None ETHTRK None

0~4294967295 None None ETHTRK None

0~4294967295 None None ETHTRK None

0~4294967295 None None ETHTRK None

0~4294967295 None None ETHTRK None

0~4294967295 None None ETHTRK None

0~4294967295 None None ETHTRK None

0~4294967295 None None ETHTRK None

Valid IP address None None ETHTRK None

0~7 0 0 ETHTRKLNK None

0~1 0 0 ETHTRKLNK None

6~7 None None ETHTRKLNK None

0~1 0 0 ETHTRKLNK None


In the ETHTRKLNK
MO, this parameter
is valid only when
0~1 None None ETHTRKLNK
SN is set to 6 or 7
and SBT is set to
0~255 255 255 ETHTRKLNK BASE_BOARD.
None

NO, YES None None ETHTRKLNK None


In the ETHTRKLNK
MO, this parameter
BASE_BOARD None None ETHTRKLNK
is valid only when
SN is set to 6 or 7.
UP, DOWN None None ETHTRKLNK None

14 characters None None ETHTRKLNK None

SHORT, LONG,
None None ETHTRKLNK None
NULL
SHORT, LONG,
None None ETHTRKLNK None
NULL

0~4294967295 None None ETHTRKLNK None

0~4294967295 None None ETHTRKLNK None

10~254 None None EXTUDT None

0~39 None None EXTUDT None

0~39 None None EXTUDTPARAGRP None

0~63 None None EXTUDTPARAGRP None

0~100 100 None EXTUDTPARAGRP None

HQ, LQ None None EXTUDTPARAGRP None

0~100 None None EXTUDTPARAGRP None

0~1000 None None EXTUDTPARAGRP None

FLOW_CTRL,
None None EXTUDTPARAGRP None
NON_FLOW_CTRL

DISABLE, ENABLE DISABLE(Disable) None GTRANSPARA None

SINGLE_RATE, SINGLE_RATE(Sin
None GTRANSPARA None
DUAL_RATE gle Rate)

0~31 characters NULL None IKECFG None


In the IKECFG MO,
0,20~28800 0 0 IKECFG IKEKLT must be
larger than IKEKLI.
In the IKECFG MO,
the value of IKEKLT
0,60~28800 0 0 IKECFG
must be larger than
that of IKEKLI.
0~63 48 48 IKECFG None

0~7 0 None IKECFG None

0~1 None None IKECFG None


The value of
0~7 None None IKECFG PEERNAME
None in an
IKEPEER MO is
Before configuring
case insensitive.
1~15 characters None None IKEPEER an
The value of MO,
IKEPEER
ensure
PEERNAMEthat the
in an
IKEPROPOSAL
IKEPEER MO must
1~99 None None IKEPEER MO that
be comprised of
corresponds to
ASCII characters.
PROPID in the
IKE_V1, IKE_V2 IKE_V1(IKE V1) None IKEPEER None
IKEPEER MO is
In the IKEPEER
configured.
MO, this parameter
MAIN,
MAIN(Main Mode) MAIN(Main Mode) IKEPEER is valid only when
AGGRESSIVE REMOTEIP in is
the
IKEVERSION set
IKEPEER
to IKE_V1.MO must
IP, FQDN None None IKEPEER None
be set to a valid IP
address of Class A,
B, or C. In addition,
Valid IP address None None IKEPEER
it cannot
If IDTYPEisbe set
set to
to
127.x.x.x
FQDN, theorvalue
0.x.x.x.
of
0~31 characters None None IKEPEER REMOTEIP
REMOTENAME in each
in
IKEPEER
each MO must
IKEPEER MO
becase
is unique.
insensitive.
0~127 characters None None IKEPEER None

DISABLE, PERIODIC(Periodic
None IKEPEER None
PERIODIC ) In the IKEPEER
MO, this parameter
10~3600 10 10 IKEPEER is valid only when
In
DPD theisIKEPEER
set to
MO, this parameter
PERIODIC.
3~30 5 5 IKEPEER is valid only when
In theisIKEPEER
LOCALIP
DPD setintothe
MO,
IKEPEERthis parameter
PERIODIC. MO must
3~10 5 5 IKEPEER is
bevalid onlyorwhen
0.0.0.0 any
DPD IP
valid is set to
address of
PERIODIC.
Class A, B, or C
Valid IP address 0.0.0.0 None IKEPEER
excluding reserved
IP addresses. That
0~7 0 None IKEPEER is,
None this parameter
cannot be set to
0.x.x.x or 127.x.x.x.
0~1 0 None IKEPEER None

0~7 0 None IKEPEER None

1~99 None None IKEPROPOSAL None


DES, 3DES,
AES128, AES192, DES(DES) DES(DES) IKEPROPOSAL None
AES256
MD5, SHA1,
SHA1(SHA1) SHA1(SHA1) IKEPROPOSAL None
AES_XCBC_96
PRE_SHARED_KE PRE_SHARED_KE PRE_SHARED_KE
IKEPROPOSAL None
Y, IKE_RSA_SIG Y(Pre-shared Key) Y(Pre-shared Key)
DH_GROUP1, DH_GROUP1(768- DH_GROUP1(2048
DH_GROUP2, bit Diffie-Hellman -bit Diffie-Hellman IKEPROPOSAL None
DH_GROUP14 Group) Group)
60~604800 86400 86400 IKEPROPOSAL None
HMAC_MD5,
HMAC_SHA1(HMA
HMAC_SHA1, SHA1(SHA1) IKEPROPOSAL None
C_SHA1)
AES128_XCBC
0~7 0 None IKEPROPOSAL None

0~1 0 None IKEPROPOSAL None

0~7 0 None IKEPROPOSAL None

0~7 0 0 IP2RSCGRP None


DSTIP in the
0~1 0 0 IP2RSCGRP None
IP2RSCGRP MO
must be a valid IP
address of Class A,
0~7 None None IP2RSCGRP None
TheorRSCGRP
B, C. In addition, MO
In
that the
it cannothas IP2RSCGRP
the
be set same to
MO,
RSCGRPID
127.x.x.x the logic asAND
or 0.x.x.x.that
0~15 0 0 IP2RSCGRP result
in
DSTIP the of inMASK
the and
IP2RSCGRP
DSTIP
MO must
IP2RSCGRP musthave be
MO the
Valid IP address None None IP2RSCGRP same
cannot as
been configured. DSTIP.
be set to
In the binary value
0.0.0.0.
into
In the which IP2RSCGRPMASK in
Valid Mask address None None IP2RSCGRP the
MO,
In IP2RSCGRP
thethe logic AND
IP2RSCGRP
MO
In
result
MO, theisthis converted,
IP2RSCGRP
of DSTIP
parameter and0
cannot
MO,
MASK
must if be precede
SN
must is
set to within
the 1.
IP IP(IP) None IP2RSCGRP None
In
In
the the
addition,
range IP2RSCGRP it can
from 0 to
same
E1_COVERBOARD
MO, as
if SBT
PT DSTIP.
isisset toto
be
5
ifThat set
and
SN is, toDSTIP
is within set
must
the
BASE_BOARD, PPP, the
255.255.255.255,
E1_COVERBOARD value
None None IP2RSCGRP be
range
range set from to this
of a network
0 to 5.
E1_COVERBOARD but
,In thiscannotparameter be setcan to
address.
the
parameter IP2RSCGRPis from 0
0.0.0.0.
be
MO, set to PPP
if SN is set to 6 or
PPP, MPGRP, ETH, to 15.
None None IP2RSCGRP MPGRP.
or 7, this parameter
ETHTRK In the IP2RSCGRP
In
must thebe IP2RSCGRP
set to to
MO,
MO, ifif PT
SN is is set
set to 6
0~15 0 0 IP2RSCGRP BASE_BOARD.
MPGRP, the value
or 7 and SBT is set
range
to BASE_BOARD, of this
parameter
this parameter is fromcan0
0~65535 None None IPPATH None
to 3.
be set to ETH or
In the IPPATH
ETHTRK. IP2RSCGRP MO,
ifMO,
LOCALIP is set to
0~7 0 0 IPPATH Noneif PT is set to
0.0.0.0,
ETH or ETHTRK, PT must be
set
this to PPP or can
parameter
0~1 0 0 IPPATH MPGRP.
be
None set to 0 or 1.
In the IPPATH MO,
if SN is within the
0~7 None None IPPATH None from 0 to 5
range
and SBT is set to
PPP, MPGRP, ETH, E1_COVERBOARD
None None IPPATH
ETHTRK , this parameter can
be set to PPP or
MPGRP.
In the IPPATH MO,
if SN is set to 6 or 7
and SBT is set to
BASE_BOARD, this
parameter can be
to 15.
In the IPPATH MO,
if SN is within the
range from 0 to 5,
SBT is set to
E1_COVERBOARD
It is recommended , and PT is set to
that IP Path be set MPGRP, the value
0~15 0 0
to QOS in a IPPATH range of this
Multiple Spanning parameter is from 0
Tree Protocol to 3.
QOS, ANY None IPPATH None
In
(MSTP) network. In In the
the IPPATH
LOCALIP IPPATHin theMO,
MO,
other scenarios, it is ifthis
SNparameter
IPPATH is set
MOtomust
6isor
0~63 None recommended
None that IPPATH 7,
In SBT
be
validthe is set
a valid
IPPATH
only IP toMO,
when
this parameter is BASE_BOARD
address
the value ofClass
PATHTYPE of and
is setA,to
set to ANY. PT
B, is
or
LOCALIP
QOS. set
C. Into ETH,
addition,
must be
Valid IP address None None IPPATH this
It parameter
cannot
different be set
from can
to of
that
If the IP path be set to 0oror0.x.x.x.
127.x.x.x
PEERIP. 1.
belongs In the IPPATH
PEERIP in the MO,
Valid IP address None None to the S1 IPPATH ifIPPATH
SN is set
LOCALIP tomust
must 6 be
or
interface, this MO
parameter is set 7, SBT
different
be isfrom
a valid set
IP to
0~47 None from 0 to 15. If the IPPATH BASE_BOARD
None of Classand
PEERIP.
address A,
IP path belongs to PT
B, or is C.
setIntoaddition,
the X2 interface, ETHTRK,
It cannot be thisset to
HQ, LQ HQ(High Quality) HQ(High Quality)
this parameter is IPPATH parameter
127.x.x.x orcan
None be
0.x.x.x.
set from 16 to 47. set to 0 or 1.
S1, X2 None S1(S1) IPPATH None

DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) IPPATH None

0~4294967295 None None IPPATH None

0~4294967295 None None IPPATH None

0~4294967295 None None IPPATH None

0~4294967295 None None IPPATH None

0~4294967295 None None IPPATH None

0~4294967295 None None IPPATH None


NORMAL, FAULT,
CHECK_DISABLE None None IPPATH None
D In the IPPATH MO,
this parameter is
0~15 None None IPPATH In
validtheonly
IPPATH whenMO,
ifJNRSCGRP
SN is withinisthe set
range
to ENABLE.
SRCIP from
in the 0 to 5,
0~47 characters NULL None IPPATH None
this parameter
IPPATHRT MO must
be set to
must be set to a
BASE_BOARD, E1_COVERBOARD
valid IP address of
None None IPPATH
E1_COVERBOARD .Class
In the A,IPPATH
B, or C. MO,In
In theisIPPATH
if PT
addition, set to MO,
it cannot
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) IPPATH ifbe
SN
DSTIPsetisto
LOOPINT, set
in to 6 or
the
127.x.x.x
7, this
IPPATHRT
JNRSCGRP parameter
or 0.x.x.x. cannotMO
must
be setbe
In the toset to a
ENABLE.
IPPATHRT
Valid IP address None None IPPATHRT BASE_BOARD.
valid IP address
MO, the board of
Class A, B, with
configured or C. In
addition,
SRCIP must haveit cannot
Valid IP address None None IPPATHRT
be
an set to 127.x.x.x
IP address that
or 0.x.x.x.
is on the same
HQ, LQ None None IPPATHRT In
Nonethe IPPATHRT
network segment
MO, SRCIP mustbut
as NEXTHOPIP
be different
different from from
DSTIP.
NEXTHOPIP.
NEXTHOPIP
set to NO, in the
IPPATHRT
LOCALIP cannot be MO
must
set tobe a valid IP
0.0.0.0.
address
In the of Class A,
B, or C. In addition,
IPPMSESSION
itMO,
cannot be set to is
if BINDPATH
127.x.x.x
set to NO,or 0.x.x.x.
In the IPPATHRT
LOCALIP must be a
Valid IP address None None IPPATHRT
MO,
In thethe
valid board with
IP address of
SRCIP
Class A,must
IPPMSESSION B, orhaveC. In
0~65535 None None IPPMSESSION an
MO,
None IPifaddress
addition, BINDPATH
it cannotthatis
is
setdifferent
to NO, from
PEERIP
be set to 127.x.x.x
NEXTHOPIP
must be a valid
or 0.x.x.x. butIPon
Valid IP address None None IPPMSESSION the same
address ofnetwork
Class A,
In the
segment
B, or C. Inasaddition,
IPPMSESSION
NEXTHOPIP.
It
MO,cannot be set to is
if BINDPATH
Valid IP address None None IPPMSESSION
127.x.x.x
set to NO,or 0.x.x.x.
In the
LOCALIP must be
0~63 None None IPPMSESSION IPPMSESSION
None
different from
MO,
PEERIP. if BINDPATH is
set to NO,
If BINDPATH in the
UP, BIDIR UP(Uplink) UP(Uplink) IPPMSESSION None
LOCALIP must be
IPPMSESSION
This parameter is MO
different
is setonly fromPT in
to NO,
valid when
PEERIP.
the
0~10000 None None IPPMSESSION ThisDEVIP
IppmUpActState
parameter MO thatisin
is
anassociated
validIPPMSESSION
only when with
LOCALIP
MO is set in
IppmDownActStateto the
PMUP.
-10000~10000 None None IPPMSESSION IPPMSESSION
This parameter MO
is
in an
cannot
valid be
only
IPPMSESSION MO set
when to
PPPsetor toMPGRP.
IppmDownActState
is PMUP.
-10000~10000 None None IPPMSESSION This
in anparameter is
valid only
IPPMSESSION when MO
IppmDownActState
is set to PMUP.
0~1000 None None IPPMSESSION
in
Thisanparameter is
IPPMSESSION
valid only when MO
0~1000 None None IPPMSESSION is set to PMUP. in
IppmUpActState
an IPPMSESSION
IDLE, ACTING, MO is set to PMUP.
PMUP, DEACTING, None None IPPMSESSION None
UNKNOWN
IDLE, ACTING,
PMUP, DEACTING, None None IPPMSESSION None
UNKNOWN
FOUR_TUPLE, FOUR_TUPLE(FO FOUR_TUPLE(FO
IPPMSESSION None
THREE_TUPLE UR_TUPLE) UR_TUPLE)

NO, YES NO(No) NO(No) IPPMSESSION None

0~65535 None None IPPMSESSION None

NO, YES None None IPPMSESSION None

0~4294967295 None None IPPMSESSION None

0~4294967295 None None IPPMSESSION None

None None None IPPMSESSION None

0~7 0 0 IPRT None

0~1 0 0 IPRT None

0~7 None None IPRT None


In the IPRT MO, if
SN is within the
range from 0 to 5,
this parameter must
In
be the
set IPRT
to MO,
In
DSTIPthe IPRT
or MASK MO, if
BASE_BOARD, E1_COVERBOARD
In the IPRT
RTTYPE MO,
E1_COVERBOARD
None None IPRT can be set to to IF
.and parameter
is set
this IFTonlyis set tois
0.0.0.0
In theonlyIPRT when
MO, if
PPP, MPGRP, ETH, valid
PPP, the when
value
If IFT is set to PPP IPRT both
SN isofsetthemto 6 are
or set
7,
ETHTRK, PPP(PPP Link) None SBT isofset
range this to
or MPGRP, you are to
this
In 0.0.0.0.
the parameter
IPRTisMO, must
if 0
LOOPINT, VI E1_COVERBOARD
parameter from
advised to set IFNO In
In
be
SBT the
the
set isIPRT
binary
to
set MO,
to value the
and
to RTTYPE
15. AND result is set
0~32 0 to 0. IPRT logical
into which
BASE_BOARD.
BASE_BOARD, MASK in
to
In IF. IPRT MO, this
If IFT is set to VI, of the
the DSTIP
IPRT MO
parameter andmust is be
if
RTTYPE
MASK must is set to IF
you are advised to converted,
set toIFTNEXTHOP. 0 becannot
NEXTHOP, IF None None IPRT and
equal is set to
set IFNO to 1. In the to
precede
MPGRP, IPRT DSTIP.
1. In
theMO, value if
That
addition,
SBT is,
is DSTIP
setit tocan be must
range
NEXTHOPIP
be set of
to this
a networkin the
Valid IP address None None IPRT set to 0.0.0.0
E1_COVERBOARD and
parameter
IPRT
address. MO is
must from be 0a
255.255.255.255.
,tothis parameter
3. IP
valid
DSTIP inaddress
the IPRT of
In thebe
must IPRT set MO,to IF.if
Valid Mask address None None IPRT Class
MO
Balanced
either A,
must B,
of MASKbe ora C.
routes validIn
and
addition,
IP address
are
DSTIP not is itsetcannot
oftoClass
supported.
be
A, Bset
Balanced
0.0.0.0,ortoC. 127.x.x.x,
the Inother
routes
Valid IP address 0 None IPRT 0.x.x.x,
addition,
are
must or
alsoitroutes
those cannot
be set to
255.255.255.255.
be
thatsethave
0.0.0.0. to 127.x.x.x
the same
In
Anthe
or IPRT
0.x.x.x.
destination
IPRT MO MO,
andwhose
1~255 60 60 IPRT this parameter is
An IPRT
priority.
MASK MO
Therefore,
and whose
DSTIP
STATICHOST, valid
MASK
each
are only
and
IPRT
both setwhen
DSTIP
MOto all
STATICGATEWAY, None None IPRT RTTYPE
are
must
0s
None both
have
indicates isaset
set to
auniqueto
all
HOST, GATEWAY NEXTHOP.
0s indicates
combination
default route. a
of
default route. and
NEXTHOPIP
0~47 characters NULL None IPRT None
PREF.
PPP, MPGRP, ETH,
ETHTRK, None None IPRT None
LOOPINT, VI
0~32 None None IPRT None

0~7 0 0 IPSECBIND None

0~1 0 0 IPSECBIND None

6~7 None None IPSECBIND None


In the IPSECBIND
MO, this parameter
BASE_BOARD None None IPSECBIND
is
In valid only when
the IPSECBIND
SN isthis
MO, setparameter
to 6 or 7.
ETH, ETHTRK None None IPSECBIND is valid only
In the IPSECBINDwhen
SBT this
MO, is set to
parameter
BASE_BOARD.
is valid only when
0~1 None None IPSECBIND Any
SBT twoand PT are
IPSECPOLICY
both set to valid
0~15 characters None None IPSECBIND MOs
Nonecannot have
values.
the same
combination of
1~15 characters None None IPSECPOLICY SPGN
Any twoand SPSN.
The value of SPGN
IPSECPOLICY
in an
MOs cannot have
1~10000 None None IPSECPOLICY IPSECPROPOSAL
the same
MO is case of
combination
3000~3999 None None IPSECPOLICY insensitive.
SPGN
None and SPSN.

0~15 characters None None IPSECPOLICY None


0~15 characters None None IPSECPOLICY None
DISABLE,
PFS_GROUP1, DISABLE(Disable) DISABLE(Disable) IPSECPOLICY None
PFS_GROUP2
LOCAL(Local LOCAL(Local
GLOBAL, LOCAL IPSECPOLICY None
In the
Configuration) Configuration)
IPSECPOLICY MO,
this parameter is
30~604800 3600 3600 IPSECPOLICY In theonly when
valid
IPSECPOLICY
LTCFG is set toMO,
0,1843200~429496 this parameter is
LOCAL.
69120000 69120000 IPSECPOLICY
7295 valid only when
LTCFG is set to
0~7 0 None IPSECPOLICY LOCAL.
None

0~1 0 None IPSECPOLICY None

0~7 0 None IPSECPOLICY None


PROPNAME in the
IPSECPROPOSAL
1~15 characters None None IPSECPROPOSAL
MO is case
In the
insensitive.
TUNNEL, IPSECPROPOSAL
TUNNEL(Tunnel) TUNNEL(Tunnel) IPSECPROPOSAL None
TRANSPORT MO, TRANMODE is
set to ESP or
AH, ESP, AH_ESP ESP(ESP Protocol) ESP(ESP Protocol) IPSECPROPOSAL AH_ESP,
In the
ESPAUTHALG and
IPSECPROPOSAL
ESPENCALG
MO, this parameter
NULL, MD5, SHA1 SHA1(SHA1) SHA1(SHA1) IPSECPROPOSAL In the be
cannot
is valid onlyboth
when set
IPSECPROPOSAL
to NULL.
TRANMODE is set
MO,
to AH this AH_ESP.
parameter
NULL, MD5, SHA1 SHA1(SHA1) SHA1(SHA1) IPSECPROPOSAL In the oronly
is valid when
IPSECPROPOSAL
TRANMODE is set
NULL, DES, 3DES,
MO,
to ESPthisorparameter
AH_ESP.
AES128, AES192, AES128(AES128) AES128(AES128) IPSECPROPOSAL
is valid only when
AES256
TRANMODE is set
0~7 0 None IPSECPROPOSAL to ESP or AH_ESP.
None

0~1 0 None IPSECPROPOSAL None

0~7 0 None IPSECPROPOSAL None

DISABLE, ENABLE None None LOCALETHPORT None

UP, DOWN None None LOCALETHPORT None

0~4294967295 None None LOCALETHPORT None

0~4294967295 None None LOCALETHPORT None

0~4294967295 None None LOCALETHPORT None

0~4294967295 None None LOCALETHPORT None


IP in the LOCALIP
MO must be set to
Planned IP address
a
Invalid IP address
the binary value
of the local
Valid IP address 192.168.0.49 LOCALIP of Class
into which A,MASK
B, or C.
in
maintenance
Planned subnet In addition,
the LOCALIP it MO is
channel on a board
mask of the local cannot be 127.x.x.x
converted, 0 cannot
Valid Mask address 255.255.255.0 LOCALIP or 0.x.x.x.1. In
maintenance precede
channel on a board addition, it cannot
0~7 0 0 LR be
Noneset to 0.0.0.0 or
255.255.255.255.

0~1 0 0 LR In
Nonethe LR MO, if
SBT is set to
E1_COVERBOARD
0~7 None None LR None
, this parameter
In
mustthebe LRset MO, to if PT
In
is the to
set LRMPGRP,
MO, this
MPGRP, ETH, MPGRP.
None None LR parameter
the value is valid
ETHTRK In the LR range
MO, if of
only
this when LRSW
parameter is is
SBT
In the isLRsetMO, to this
set
from to0ENABLE.
to 3.
0~3 None None LR BASE_BOARD,
parameter is valid this
In the LR MO, if PT
parameter
only when can be is
LRSW
is set to ETH, ETH the
set
set
In to ETH
to range
the ENABLE.
LR MO, or orthis
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) LR value
ETHTRK,
None thisof CIR
ETHTRK.
In the LR
parameter
is from
parameter 32MO, is
to
can
if PT
valid
be
is
onlyset to ETH, the is
set towhen
360000. 0 or 1. LRSW
32~360000 None None LR value
set
In theto range
ENABLE.
LR MO, of ifCIR
PT
is
In from
the to
is set 32 to
LRETHTRK,
MO, if PT
300000.
In
is the
theset LRETH,
to
value MO,
range this
the of
32~300000 None None LR In the range
LR MO, if SN
parameter
value
this parameter CIR is isPT
valid
of
is
only
is within
set
from to0to
when the
ETHTRK, rangeis
LRSW
to360000.
300000.
from 32
from
the 0 to 5,
In the LR MO, if of
set value
to ENABLE. this
range PT
0~300000 None None LR parameter
this
In theparameter
LRETHTRK,mustifisbe
MO, PT
is set to MPGRP
set
from
is
the to
set 32to to
value ETH, 300000.
range theof
BASE_BOARD, If PT is set to E1_COVERBOARD
None None LR In the
value
this LR MO,
range
parameter of ifisPT
E1_COVERBOARD MPGRP, you are .is set0
DLCIR
from 32toto MPGRP
isto from
300000.
31744.32 to
advised to set In
DLCIR to 31744. In the
the value
540000.
the LR
LR MO, MO, ifif of
range SN
PT
32~540000 None LR is
In set
this to 6
parameter
is set to MPGRPPT
the LR or
MO, 7, is
if this
If PT is set to ETH parameter must of be
from
is
theset 32to to
value 155000.
ETHTRK,
range
or ETHTRK, you set to
the
this value
parameter rangeisof
0~7 0 are
0 advised to set MPGRP None
BASE_BOARD.
DLCIR
from 0 to is 155000.
from 32 to
DLCIR to 300000.
300000.
0~1 0 0 MPGRP In the LR MO, if PT
None
is set to MPGRP,
the value range of
0~5 None None MPGRP DLCIR
None is from 32 to
31744.
0~3 None None MPGRP None

DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) MPGRP None


MASK in the
NONAUTH, PAP, PAP(PAP PAP(PAP MPGRP MO must
MPGRP None
In
bethe MPGRP
valid, that is,MO, 0 is
CHAP Authentication) Authentication) In
thethe
not
MPGRP
value
allowed of to MO,
this parameter
LOCALIP is
precede 1.must
In be
0~67 characters None None MPGRP valid only
different when
from
addition,
In the MPGRP it canthatbe of
AUTH
PEERIP. is set to MO, PAP
set
this to 0.0.0.0 oris
parameter
or CHAP. in the
LOCALIP
0~19 characters None None MPGRP 255.255.255.255.
valid only when
MPGRP
In is MO
the MPGRP
AUTH set to mustMO,
PAP
be a
after valid
the
or CHAP. IP
logical
Valid IP address 0.0.0.0 None MPGRP address
AND of Class
operation is A,
Class
appliedB,toorLOCALIP
Class C.
In
andaddition,
MASK, itboth
Valid Mask address 0.0.0.0 None MPGRP cannot be setIDtoand a
the Network
reserved
the Host ID IP cannot
address,
be all 0s orthat allis,
Fs
0.x.x.x
except or when127.x.x.x,
but it can be
LOCALIP set0s.
is all to
0.0.0.0.
In the MPGRP MO,
MASK cannot be all
0s if LOCALIP is
In the MPGRP MO,
LOCALIP must be
different from
PEERIP.
PEERIP in the
MPGRP MO must
be a valid IP
Valid IP address 0.0.0.0 None MPGRP address of Class A,
In
B, the
or C. MPGRP MO,
In addition,
this parameter
it cannot be set to a is
LONG, SHORT LONG(Long) LONG(Long) MPGRP valid
reserved onlyIPwhen
MCPPP
address,isthat setis,
to
ENABLE.
0.x.x.x or 127.x.x.x,
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) MPGRP None
In
butthe MPGRP
it can be setMO, to
MAXMFLEN
0.0.0.0. must
128~1500 256 256 MPGRP be
None larger than
In the MPGRP
MAXSFLEN MO,
and
MAXMFLEN
the minimum must
1~512 192 192 MPGRP be larger than
difference is 2.
MAXSFLEN
In the MPGRP and
MO,
the minimum
this parameter is
3~1500 1500 1500 MPGRP In the MPGRP
difference is 2. MO,
validtheonly
InMCPPP MPGRPwhen MO,
ifIn the MPGRP is setMO,
to
MUXCP
this is set to
parameter is
ENABLE
this and MHO
parameter is
1~1000 10 10 MPGRP ENABLE.
valid
is
validsetonly when
to LONG,
only when this
MUXCP
parameter
MUXCP is can is set
set to
be
to
ENABLE.
set
ENABLE.to 4 or 8.
4,8 8 8 MPGRP
In the MPGRP MO,
if MCPPP is set to
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) MPGRP ENABLE
None and MHO
In the to
is set MPGRP
SHORT, MO,
the
this value of must
parameter
0~1000 100 100 MPGRP MPDAAT
be set to 4. must be
larger than or equal
In the MPGRP MO,
to that of MPDADT.
MPDAAT must be
0~1000 50 50 MPGRP
INITIAL, larger than or equal
STARTING, to MPDADT.
UP, DOWN
CLOSED, None None MPGRP None
INITIAL,
STOPPED,
STARTING,
CLOSING,
CLOSED, None None MPGRP None
STOPPING,
STOPPED,
REQSENT,
CLOSING,
ACKRCVD, None None MPGRP None
STOPPING,
ACKSENT,
REQSENT,
OPENED
ACKRCVD,
Valid IP address None None MPGRP None
ACKSENT,
OPENED
Valid IP address None None MPGRP None

Valid IP address None None MPGRP None

DISABLE, ENABLE None None MPGRP None

128~1500 None None MPGRP None

DISABLE, ENABLE None None MPGRP None

DISABLE, ENABLE None None MPGRP None

DISABLE, ENABLE None None MPGRP None

DISABLE, ENABLE None None MPGRP None


0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

Valid IP address None None MPGRP None


In the MPGRP MO,
this parameter is
E1_COVERBOARD None None MPGRP valid only when SN
is within the range
from 0 to 5.
0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

0~4294967295 None None MPGRP None

0~7 0 0 MPLNK None


In the MPLNK MO,
0~1 0 0 MPLNK SRN must be the
same as E1T1SRN.
0~5 None None MPLNK None
In the MPLNK MO,
this parameter is
0~15 0 0 MPLNK valid only when SN
In
and the SBTMPLNK
are bothMO,
this
In the parameter
MPLNK
set to valid values. is
MO,
0~3 0 0 MPLNK ifvalid
the only
value
Before adding anwhen
of SN SN is
and
MPLNK SBTMO,
different are both
from that of
ensure
In
set the MPLNK
to valid MO,
values.
E1T1SN,
that indicating
0~1 0 0 MPLNK SRNthere mustare E1/T1
be the
an
ports inter-board
same on as the board
E1T1SRN.
MLPPP
associated link,with
TSN
0~5 None None MPLNK must
E1T1SN.
In be all
the MPLNK MO,
TS1, TS2, TS3,
selected.
In
thisthe MPLNK MO,
parameter is
TS4, TS5, TS6,
The
valid only value
this valid
parameter
whenisSN,
TS7,
0~7 TS8, TS9, 0 0 MPLNK range
valid only
SBT, of TSN
when
E1T1SN, inand
the
SN
TS10, TS11, TS12,
MPLNK
and SBTMO
E1T1SBT arevaries
are both
all set
TS13, TS14, TS15,
with tothe
setvalid
to setting
valid values.
values. of
TS16, TS17, TS18, None None MPLNK
WORKMODE:If
TS19, TS20, TS21,
WORKMODE in the
TS22, TS23, TS24,
128~1500 1500 1500 MPLNK associated
None E1T1
TS25, TS26, TS27,
MO is set to
TS28, TS29, TS30,
E1_UBA or E1_BA,
TS31
the value range is
from TS1 to TS31; if
WORKMODE in the
associated E1T1
MO is set to T1, the
value range is from
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) MPLNK None

DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) MPLNK None

If SBT is set to
1~65535 3000 3000
BASE_BOARD or MPLNK None
In the MPLNK MO,
BACK_BOARD, this parameter is
E1_COVERBOARD None you
Noneare advised to MPLNK valid only when SN
set MPGRPSBT to In the MPLNK
is within MO,
the range
BASE_BOARD. this
fromparameter
0 to 5. is
E1_COVERBOARD None If SBT is set to MPLNK valid only when SN
INITIAL, E1_COVERBOARD and SBT are both
STARTING, , you are advised to set to valid values.
UP, DOWN
CLOSED, None None
set to MPGRPSBT MPLNK None
STOPPED, to
CLOSING, E1_COVERBOARD
None None MPLNK None
STOPPING, .
REQSENT,
ACKRCVD,
128~1500 None None MPLNK None
ACKSENT,
OPENED
DISABLE, ENABLE None None MPLNK None
In the MPLNK MO,
if E1T1SN is the
DISABLE, ENABLE None None MPLNK same
None as SN,
E1T1SBT must be
the same as SBT.
E1_COVERBOARD None None MPLNK In the MPLNK MO,
this parameter is
valid only when SN,
0~4294967295 None None MPLNK None
SBT, E1T1SN are
all set to valid
0~4294967295 None None MPLNK values.
None

0~4294967295 None None MPLNK None

0~4294967295 None None MPLNK None

0~4294967295 None None MPLNK None


IP in the OMCH MO
must be set to an IP
0~4294967295 None None MPLNK address
None of Class A,
B, or C. In addition,
it cannot be set to
0~4294967295 None None MPLNK None
127.x.x.x or 0.x.x.x.
In the logic AND
result of IP and
0~4294967295 None None MPLNK None
MASK in an OMCH
PEERIP
MO, neither in the
the
OMCH
Network
MASK MO
in ID
an must
nor
OMCH be
the
MASTER, SLAVE None None OMCH None
set
Host toIDan IP
can
MO must be set to address
be all
of
0s Class A, B,(0orisC.
or allmask
a valid 1s.
Valid IP address None None OMCH In
not allowed ittoMO,
addition,
the OMCH
cannot
IP mustbe
precede 1).set
be to
different
127.x.x.x
from DSTIP.
MASK or 0.x.x.x.
in the OMCH
Valid IP address None None OMCH In
MOthe logic
OMCH
cannot AND
beMO,set if
result
BRT isof
to 0.0.0.0. PEERIP
set to YES,
and
IP PEERMASK
must
In the OMCH MO,inif
be different
Valid IP address None None OMCH
an
from
BEAR OMCH
DSTIP.
is set MO,to IP,
neither
In the OMCH
MASK the Network
can beMO,
set toif
ID
BRT noris the
set
255.255.255.255. Host
to YES,ID
can
IP mustbe all be0s or all
different
1s
from if PEERMASK
NEXTHOPIP.is
not
In thesetOMCHto MO,
255.255.255.255.
IP must be different
In
fromthePEERIP.
OMCH MO,
PEERMASK in an
OMCH MO must be
set to a valid mask
(0 is not allowed to
precede
In
In the
the OMCH
OMCH 1). MO, MO, if if
PEERMASK
BRT
BRT is set
is set toto in
YES,
YES, the
Valid IP address None None OMCH
OMCH must
DSTIP
DSTMASK MO must cannot
be abe
be setthat
network
valid, toaddress.
0.0.0.0.
is, 0 is
0~7 0 0 OMCH In
None
not the OMCHtoMO, if
allowed
BEAR
BRT
precede is issetsetto
1. Into
YES,IP,
MASK can
DSTIP
addition, must bebeset
it can be to
0~1 0 0 OMCH None
255.255.255.255.
0.0.0.0
set or an IP
to 0.0.0.0 or
address of Class A,
255.255.255.255.
B,
In or COMCH
the excluding MO, if
0~7 None None OMCH None
reserved
BRT is setIPto YES,
addresses.
a route is regarded That is,
IPV4 IPV4(IPV4) IPV4(IPV4) OMCH In
as the
itNone
cannot OMCH
a valid be MO,
set
default to
this parameter
127.X.X.X
one only when or is
valid
0.X.X.X.
DSTIP onlyandwhen
NO, YES NO(No) NO(No) OMCH BEAR
In the
DSTMASK is
OMCH setaretoMO,both if
IPV4,
BEAR
set and
is set
to 0.0.0.0. SNtoand IPV4
SBT
and
In the are
BRTOMCH set toMO,
is set valid
to if
Valid IP address None None OMCH values.
YES,isa set
BRT route is
to YES
In the OMCH
regarded as aMO, valid if
and DSTMASK is
BRT
In the
default isOMCHset
one toonly
YES,
MO,
Valid IP address None None OMCH set to
NEXTHOPIP
this
when parameter
DSTIP and must
is
255.255.255.255,
be
validon
DSTMASK the
only same
when
NEXTHOP(Next DSTIP mustare be bothset
NEXTHOP None OMCH network
BEAR,
setan to IP segment
SN,
0.0.0.0. and of
Hop) to address
as
SBT IParein aallDEVIP
setMO,
In the
Class OMCH
A, B, or C.toInif
MO
valid
BEAR
this whose
values
and
parameter PT
BRTand is
isare
1~255 60 60 OMCH addition, it cannot
not
BRT set
tois
set set
valid IPV4
only to
set127.x.x.x
toand
when YES.
be to
LOOPINT.
YES
BRT is set In
respectively,
to YES.
or other 0.x.x.x.
addition,
DSTIP must be
Valid IP address None None OMCH In the OMCH MO, if
NEXTHOPIP
different from must
IP.
BRT is set to YES,
NORMAL, be
In set OMCH
the to an IPMO,
if either of DSTIP
ABNORMAL, None None OMCH address
None
this of Class A,
parameter
and DSTMASKisis
UNKNOWN B, or C
validtoonly and cannot
when
set 0.0.0.0, the
be set
BEARmust to 127.x.x.x
is setalso to IPV4
INUSE, UNUSED None None OMCH other
None be
or
In 0.x.x.x.
setthe
and toBRTOMCH
0.0.0.0.is setMO, to
In
this
YES.the OMCH MO,
parameter is
In the OMCH MO,
this parameter
valid only when is
BASE_BOARD None None OMCH this parameter is
valid only
BEAR and when
SN areRT
valid only when
is setset
both to NEXTHOP.
to valid
BEAR is set to IPV4
0~7 0 0 PACKETFILTER values.
None
and BRT is set to
YES.
0~1 0 0 PACKETFILTER None

6~7 None None PACKETFILTER None

ETH, ETHTRK None None PACKETFILTER In the


None
PACKETFILTER
MO, this parameter
0~3 None None PACKETFILTER is valid only when
SN, SBT, and PT
are all set to valid
3000~3999 None None PACKETFILTER None
values.

PERMIT, DENY PERMIT(Permit) PERMIT(Permit) PACKETFILTER None


In the
PACKETFILTER
BASE_BOARD None None PACKETFILTER MO, this parameter
is valid only when
SN is set to 6 or 7.
0~4294967295 None None PACKETFILTER None
0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER None

0~4294967295 None None PACKETFILTER IP


None in the
In the binary value
PINGFILTER MO
into
mustwhich MASK
be a valid IPin
Valid IP address None None PINGFILTER the PINGFILTER
address of Class A,
MO
B, orisC. converted,
In addition, 0
cannot
It cannot precede
be set to1.
Valid Mask address None None PINGFILTER In addition,
127.x.x.x orthe
0.x.x.x.
binary value can be
set to
0~7 0 0 PORTSECURITY None
255.255.255.255,
but
In the cannot be set to
0~1 0 0 PORTSECURITY 0.0.0.0.
PORTSECURITY
None
MO, if SN is within
the
In the range from 0 to
0~7 None None PORTSECURITY None
5, this
the parameter
PORTSECURITY
In
must
MO, ifbe
SBT
PORTSECURITY setistoset to
BASE_BOARD, E1_COVERBOARD
BASE_BOARD,
MO, if SBT is setthis to
None None PORTSECURITY
E1_COVERBOARD .BASE_BOARD
parameter can be and
In
setthe
PT to set
is ETH.to ETH,
ETH, E1T1 ETH(Ethernet Port) ETH(Ethernet Port) PORTSECURITY PORTSECURITY
In the
this parameter can
MO, if SN
to 0isorset
PORTSECURITY
be set 1. to 6
or
MO, 7,
In the this
if SBT parameter
is set to
0~7 None None PORTSECURITY must be set to
E1_COVERBOARD
PORTSECURITY
BASE_BOARD.
, this ifparameter
MO, SBT is set to
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) PORTSECURITY must
None set to
be
E1_COVERBOARD
E1T1.
and PT is set to
E1T1, the value
0~7 0 0 PPPLNK None of this
range
parameter is from 0
to 7.
LOCALIP in the
PPPLNK MO must
be a valid IP
address of Class A,
Class B, or Class C.
In addition, it
0~1 0 0 PPPLNK None
cannot be set to a
reserved IP
0~5 None None PPPLNK address,
None that is,
In the PPPLNK
0.x.x.x or 127.x.x.x, MO,
this
but itparameter
can be setisto
0~15 None None PPPLNK valid only when SN
0.0.0.0.
In
and
In the
the SBT PPPLNK
PPPLNK are both MO,
MO,
this parameter
set to validmust
LOCALIP values. is
be
0~7 None None PPPLNK valid
differentonlyfrom when SN
and
PEERIP.SBT are both
NONAUTH, PAP, PAP(PAP PAP(PAP set
If to
PTvalid valid
in thevalue values.
DEVIP
PPPLNK None
The
CHAP Authentication) Authentication) In the PPPLNK
MO
range of TSNPPP,
is set to in MO,
the
this parameter
LOCALIP
PPPLNK MO varies in the is
0~67 characters
TS1, TS2, TS3, None None PPPLNK valid
PPPLNK
with onlysetting
the when
MO mustof
In
bethe
AUTH PPPLNK
is setfrom
different to PAP MO,
IP
TS4, TS5, TS6, WORKMODE:If
this parameter is
TS7, or
in CHAP.
the DEVIP MO.
0~19 TS8, TS9,
characters None None PPPLNK WORKMODE
valid
In
If theonly
PT inPPPLNK when in the
MO,
TS10, TS11, TS12, MASK
associated inthethe DEVIP
E1T1
AUTH
LOCALIP
MO is is
not set
must
set totoPAPbe
TS13, TS14, TS15, PPPLNK
MO is set to MO must
or
PPP,CHAP.
different from
LOCALIP
TS16, TS17, TS18, None None PPPLNK be valid,
E1_UBA that
or E1_BA, is, in0 is
PEERIP.
the
not PPPLNK toMOis
TS19, TS20, TS21, the allowed
value range
If PEERIP
must
precede 1.toisInTS31;
be different
TS22, TS23, TS24, from TS1
Valid inconsistent with
TS25,IPTS26,
address
TS27, 0.0.0.0 None PPPLNK from
addition,IP
(2) If WORKMODEinitthe
can be
the
DEVIP
set local
to MO.IP address
0.0.0.0 In or
TS28, TS29, TS30, in the associated
configured
addition, attwo the IP
TS31
Valid Mask address 0.0.0.0 None PPPLNK E1T1 MOthe
255.255.255.255. is set to
peer
addresses
In the end,
PPPLNK the
must PPP be
MO,
T1,
In thethe value range
on
MASK
is thePPPLNK
negotiation
from network
cannot
TS1
fails.
to
MO,
be all
MRU
PEERIP
segments must be
thelarger
inthat are
Valid IP address 0.0.0.0 None PPPLNK 0s if LOCALIP
TS24. is
than
PPPLNK or equal to
all 0s.MO
exclusive
not of each must
MAXSFLEN.
be a valid
other. IP
In the PPPLNK MO,
In the
address PPPLNK
of inClass MO,
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) PPPLNK LOCALIP
None must
MASK be allA,
the
MAXMFLEN
Class
PPPLNK B, or
MO must
Classmust C.
0s the
In if LOCALIP
PPPLNK isMO,all
be
In
be larger
addition,
different than it
from
0s. must be larger
MRU
1~512 192 192 PPPLNK MAXSFLEN
cannot
LOCALIP be in and
setthe to a
than
the or equal
minimum to
reserved
MPGRP IP
MO. In
MAXMFLEN.
difference is 2.
address,
addition, that
the is, IP
two
3~1500 1500 1500 PPPLNK In
In the
the PPPLNK
PPPLNK MO,
0.x.x.x
addresses
In the
this PPPLNKisMO,
or
parameter
127.x.x.x,
must be
MO,
this
but
on
this parameter
itparameter
can be setisto
network is
valid
valid only
only when
1~1000 10 10 PPPLNK 0.0.0.0.
segments
valid
MUXCP onlyiswhen that
when
set are
to
MUXCP
exclusive
MUXCP is
is ofset
set each to
to
ENABLE.
ENABLE.
other.
ENABLE.
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) PPPLNK None
If SN in the
PPPLNK MO is
128~1500 1500 1500 PPPLNK different
None from SN in
the OMCH MO,
LOCALIP in the
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) PPPLNK PPPLNK
None MO must
be different from
LOCALIP in the
DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) PPPLNK None
OMCH MO.

1~65535 3000 3000 PPPLNK None


INITIAL,
STARTING,
UP, DOWN
CLOSED, None None PPPLNK None
INITIAL,
STOPPED,
STARTING,
CLOSING,
CLOSED, None None PPPLNK None
STOPPING,
STOPPED,
REQSENT,
CLOSING,
ACKRCVD, None None PPPLNK None
STOPPING,
ACKSENT,
REQSENT,
OPENED
ACKRCVD,
ACKSENT,
OPENED
INITIAL,
STARTING,
CLOSED,
STOPPED,
CLOSING,
None None PPPLNK None
STOPPING,
REQSENT,
ACKRCVD,
Valid IP address None None PPPLNK None
ACKSENT,
OPENED
Valid IP address None None PPPLNK None

Valid IP address None None PPPLNK None

DISABLE, ENABLE None None PPPLNK None

DISABLE, ENABLE None None PPPLNK None

DISABLE, ENABLE None None PPPLNK None

128~1500 None None PPPLNK None

DISABLE, ENABLE None None PPPLNK None

0~4294967295 None None PPPLNK None

0~4294967295 None None PPPLNK None

0~4294967295 None None PPPLNK None

0~4294967295 None None PPPLNK None

0~4294967295 None None PPPLNK None

Valid IP address None None PPPLNK None


In the PPPLNK MO,
FFDPHOLD must
1~1000 10 10 PPPLNK
be smaller than
FFAPHOLD.
1~1000 6 6 PPPLNK None
In the PPPLNK MO,
this parameter is
E1_COVERBOARD None None PPPLNK valid only when SN
is within the range
from 0 to 5.
0~4294967295 None None PPPLNK None

0~4294967295 None None PPPLNK None

0~4294967295 None None PPPLNK None

0~4294967295 None None PPPLNK None

0~4294967295 None None PPPLNK None


In the PRI2QUE
0~4294967295 None None PPPLNK MO,
Noneif PRI1 is set to
0, the value of PRI0
In thebe
must PRI2QUE
larger than
0~63 46 46 PRI2QUE MO, if
or equal PRI2 is set
to that of to
0, the value of PRI1
PRI1.Otherwise,
In thebe
must PRI2QUE
larger than
the
MO, value
if PRI3of is
PRI0
set
0~63 34 34 PRI2QUE or equal
must be to that
larger of to
than
0, the value
PRI2.Otherwise, of PRI2
that
In the
must ofbePRI1.
PRI2QUE
larger than
the
MO, value
if PRI4of is
PRI1
set
0~63 26 26 PRI2QUE or equal
must to that of to
0, thebe larger
value
PRI3.Otherwise,
than
of PRI3
that
In the
must ofbePRI2.
PRI2QUE
larger than
the
MO, value
if PRI5of is
PRI2
set
0~63 18 18 PRI2QUE or equal
must be to that
larger of to
than
0, the value
PRI4.Otherwise, of PRI4
that
In the
must ofbePRI3.
PRI2QUE
larger than
the
MO, value
if PRI6of is
PRI3
set
0~63 10 10 PRI2QUE or equal
must to that of to
0, thebe larger
value
PRI5.Otherwise,
than
of PRI5
that
must ofbePRI4.
larger than
the value of PRI4
0~63 0 0 PRI2QUE or equal to that
must be larger than of
PRI6.Otherwise,
that of PRI5.
the value of PRI5
0~63 0 0 PRI2QUE None
must be larger than
that of PRI6.
0~7 0 0 RSCGRP None

0~1 0 0 RSCGRP None

In the RSCGRP
0~7 None None RSCGRP None
MO, if SN is within
the range from 0 to
IP None None RSCGRP 5,
In
None this
In the parameter
the RSCGRP
RSCGRP
must
MO, if PTset
MO, be
if SBT isistosettoto
set
E1_COVERBOARD
BASE_BOARD,
PPP, the value this
BASE_BOARD,
None None RSCGRP .range
parameter of this can be
E1_COVERBOARD
In
set the RSCGRP
to ETH
parameter orfrom 0
is
PPP, MPGRP, ETH, MO,
ETHTRK.
to 15. if SN is set to 6
None None RSCGRP opr 7, this
ETHTRK In the RSCGRP
In the RSCGRP
parameter
MO, ifif PT
MO, SBTismust
isset be
settoto
0~15 0 0 RSCGRP set
MPGRP,to
E1_COVERBOARD the value
0, 1, 2, 3, 4, 5, 6, 7, ,BASE_BOARD.
this parameter
range of this can
8, 9, 10, 11, 12, 13, be set to PPP
parameter is from 0 or
None None RSCGRP None
MPGRP.
to
14, 15, In 3.
the RSCGRP
DEFAULTPORT In the RSCGRP
MO, this parameter
MO, TXCBS must
KBPS None None RSCGRP mustifbe PTsetis toset to
be
ETH larger
or than or
ETHTRK,
KBPS if BEAR is
equal
this to TXBW.can
parameter
set to IP.
32~360000 None None RSCGRP In
be the
Noneset RSCGRP
to 0 or 1.
MO, if PT is set to
PPP or MPGRP, the
32~540000 None None RSCGRP None
value range of this
parameter is from
The recommended
64 to 200000.
64~400000 None value is twice the RSCGRP In
In the
the RSCGRP
RSCGRP
TX bandwidth. MO,
The recommended MO, this
if PTparameter
is set to
is
ETHvalid
or only
ETHTRK, when
64~450000 None value is twice the RSCGRP
SN,
the BEAR,
value SBT,of
range
TX bandwidth. In the RSCGRP
PT,
this and RU areisall
parameter
MO,
set tothis parameter
valid values.
0~3 0 0 RSCGRP from 64onlyto 400000.
is valid when
In the RSCGRP
BEAR is set to IP.
MO, TXCBS
this parameter must
1~100 100 100 RSCGRP
bevalid
is larger than
only or
when
equal to
BEAR is TXCIR.
set to IP.
In the RSCGRP
MO, TXCBS must
be larger than or
equal to TXCIR.
In the RSCGRP
64~360000 None None RSCGRP In the RSCGRP
MO,
In thethis parameter
RSCGRP
MO,
is this
valid parameter
only when
MO,
is this
valid parameter
only when
64~540000 None None RSCGRP BEAR
is is set
validisonly to IP
when
BEAR
and
In thePT isset
RSCGRP totoIP
set
BEAR
and
In thePT isisset
RSCGRP totoIP
set
ETH
MO,
and or ETHTRK.
this
PT isparameter
set to
64~360000 None None RSCGRP ETH
MO,
is or only
this
valid ETHTRK.
parameter
when
ETH or ETHTRK.
is validisonly
BEAR
In the RSCGRPset when
to IP
BEAR
and PT isisset totoIP
set
64~540000 None None RSCGRP MO,
and TXPIR
PT is must
set to be
ETH
largerorthan
ETHTRK.
or equal
ETH
In theorRSCGRP
ETHTRK.
to
In TXCIR.
theRXPIR
RSCGRP
64~400000 None None RSCGRP MO, must
MO, TXPBS
be larger thanmust
or
be larger
equal than or
to RXCIR.
0~4294967295 None None RSCGRP equal
None to TXPIR.
In the RSCGRP
MO, TXPBS must
0~4294967295 None None RSCGRP None
be larger than or
equal to TXCBS.
0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

SINGLE_RATE,
None None RSCGRP None
DUAL_RATE

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~4294967295 None None RSCGRP None

0~7 0 0 RSCGRPALG None

0~1 0 0 RSCGRPALG None

0~7 None None RSCGRPALG None


BASE_BOARD,
None None RSCGRPALG None
E1_COVERBOARD
PPP, MPGRP, ETH,
None None RSCGRPALG None
ETHTRK

0~15 0 0 RSCGRPALG None


0, 1, 2, 3, 4, 5, 6, 7,
8, 9, 10, 11, 12, 13,
None None RSCGRPALG None
14, 15,
DEFAULTPORT
OFF, ON OFF(Off) OFF(Off) RSCGRPALG None

OFF, ON OFF(Off) OFF(Off) RSCGRPALG None

OFF, ON OFF(Off) OFF(Off) RSCGRPALG None

0~1000 30 30 RSCGRPALG None

0~10000 50 50 RSCGRPALG None

DISABLE, ENABLE ENABLE(Enable) ENABLE(Enable) RSCGRPALG None

DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) RSCGRPALG None

0~6 3 3 RSCGRPALG None


In the
RSCGRPALG MO,
0~500 50 50 RSCGRPALG the value of CCTTH
must
In thebe smaller
than that of CTTH.
RSCGRPALG MO,
0~500 25 25 RSCGRPALG
CCTTH must be
smaller than CTTH.
0~1000000 0 0 RSCGRPALG None

0~1000000 0 0 RSCGRPALG None

0~8192 1000 1000 RSCGRPALG None

0~47 None None SCTPLNK None

0~7 0 0 SCTPLNK In the SCTPLNK


None
MO, LOCIP,
SECLOCIP,
0~1 0 0 SCTPLNK None
PEERIP, and
SECPEERIP must
be mutually
0~7 None None SCTPLNK None
different with the IP
address of 0.0.0.0
1~34 17 17 SCTPLNK being
None excluded.
That is, SECLOCIP
and SECPEERIP
Valid IP address 0.0.0.0 None SCTPLNK can be both set to
all 0s, while neither
LOCIP nor PEERIP
can be set to all 0s.
The LOCIP
parameter in the
SCTPLNK MO must
be a valid IP
address of Class A,
on theC.basis
RTOINIT,
B, or of
In addition,
RTOINIT,
itRTOALPHA,
cannot be set to
RTOALPHA,
RTOBETA
127.x.x.x and the
PEERIP inorand
RTOBETA
0.x.x.x,
the the
actual
but delay
can be MO of
set to each
SCTPLNK
actual delay of must
each
transmission.
0.0.0.0.
In the SCTPLNK
be a valid
transmission. IP
The
In
MO, the formulas
SCTPLNK
LOCIP, used
address
The of Class
formulas used A,
to
MO, calculate
SECLOCIP, LOCIP, the link
B,
to or C. In addition,
calculate the link
disconnection
SECLOCIP,
PEERIP, andset to
Valid IP address 0.0.0.0 None SCTPLNK it cannot be
disconnection
duration
PEERIP,
SECPEERIP are
and must
127.x.x.xare
duration or 0.x.x.x.
scenario-specific
SECPEERIP
be mutually must
In the SCTPLNK
scenario-specific
and
be described
mutually
different as
1024~65535 None None SCTPLNK None
MO,
and LOCIP, asIP
with
described
the
follows:
different
address with
of the
0.0.0.0 IP
SECLOCIP,
follows:
1) When
address
being the0.0.0.0
of
excluded. link is
PEERIP,
1) When andlink is
the
Valid IP address 0.0.0.0 None SCTPLNK idle
being
That (that
is, is, no data
excluded.
SECLOCIP
SECPEERIP
idle (that is, no must
data
is transmitted
That
and is, SECLOCIP
SECPEERIP on
be
is mutually on
transmitted
the
and
can link),
SECPEERIP
be the set to
both
Valid IP address 0.0.0.0 None SCTPLNK different
the link), with
the the IP
heartbeat
can
all be
0s, both
while check
set to
neither is
address
heartbeat of 0.0.0.0
check is
used.
all
LOCIP 0s, In this
while
nor case,
neither
PEERIP
being In
used. excluded.
this case,
the
LOCIP link
1024~65535 None None SCTPLNK can
None
Thatlink
the
beis,nor
set PEERIP
to
SECLOCIP all 0s.
disconnection
can be
SECPEERIP set to in allthe0s.
and SECPEERIP
disconnection
duration
SCTPLNK is:MO must
can
durationbe both is: set to
10~59999 1000 1000 SCTPLNK (HB
be a +valid
RTO) *
IPneither
all 0s,
(HB + RTO) * while
MAXASSOCRETR,
address of Class A,
LOCIP nor
MAXASSOCRETR, PEERIP
where
B, or C. In addition,
11~60000 3000 3000 SCTPLNK can
where beSCTPLNK
set to all 0s.
itIncannot
the
MAXASSOCRETR be set to
MAXASSOCRETR
MO, RTOINIT
is the maximum must
127.x.x.x or 0.x.x.x,
is
be the
numberlargermaximum
of set or
than
10~59999 1000 1000 SCTPLNK but can be to
number
equal of
0.0.0.0. RTOMINon
to
retransmissions
retransmissions
and smaller thanand
the association on
1~99 12 12 SCTPLNK the
RTOMAX.
HB
None association
is the value of and
HB is the value of
HBINTER.
HBINTER.
2) When there is
1~99 25 25 SCTPLNK 2)
None
data When there is
transmission
data
on the transmission
link, the
on the link,check
heartbeat the is
1000~60000 5000 5000 SCTPLNK None
heartbeat check is
notthe
In used.SCTPLNKThe data
not used.
acknowledgment
MO, The data
2~254 10 10 SCTPLNK acknowledgment
message
MAXASSOCRETR SACK is
message
In
used
must thebe for SACK
SCTPLNK
link
larger status
thanis
used
MO, for link
detection. In this
MAXPATHRETR. status
1~253 5 5 SCTPLNK detection.
MAXASSOCRETR
case, the link In this
case,
must the
disconnection than
be link
larger
disconnection
MAXPATHRETR.
duration is:
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) SCTPLNK None
duration
RTO * is:
RTO *
MAXASSOCRETR
DISABLE, ENABLE DISABLE(Disable) DISABLE(Disable) SCTPLNK MAXASSOCRETR
None
In the SCTPLNK
MO, RTOMAX must
ALDER32, CRC32 CRC32(CRC32) None SCTPLNK be
None larger than
RTOMIN.
SCTP_TRANSFER
DISABLE, ENABLE
_CAUSE_START, ENABLE(Enable) ENABLE(Enable) SCTPLNK None
SCTP_TRANSFER In the SCTPLNK
_CAUSE_LINKDO MO, this parameter
1~254
WN, 10 10 SCTPLNK is valid only when
SCTP_STAT_DOW AUTOSWITCH is
SCTP_TRANSFER
N,
_CAUSE_PORTDI set to ENABLE.
SCTP_STAT_CON None None SCTPLNK None
SABLED,
GESTION,
SCTP_TRANSFER
SCTP_STAT_UP
_CAUSE_INIT, None None SCTPLNK None
SCTP_TRANSFER
_CAUSE_UNKNO
None
WERROR, None None SCTPLNK None
SCTP_TRANSFER
_CAUSE_NORMAL
0~34 None None SCTPLNK None
,
SCTP_TRANSFER
_CAUSE_USERDE
0~34 None None SCTPLNK None
LETE
ACTIVE, STANDBY None None SCTPLNK None

UNBLOCK(Unblock UNBLOCK(Unblock
UNBLOCK, BLOCK SCTPLNK None
) )
If
RSCGRPDLCACS
10~500 200 200 SCTPLNK None
WITCH in the
TACALG MO and
0~47 characters NULL None SCTPLNK TRMDLOLCSWITC
None
H in the TOLCALG
MO are both set to
OFF, ON ON(On) ON(On) TACALG None
ON,
TRMDLVIPUSERC
ACTH in the
OFF, ON ON(On) ON(On) TACALG
TACALG MO must
be smaller than or
0~100 100 100 TACALG equal
None to
TRMDLOLCRELTH
in the TOLCALG
0~100 100 100 TACALG None
MO and larger than
or equal to
TRMDLUSERCACT
0~100 100 100 TACALG None
H in the TACALG
MO.
0~100 100 100 TACALG None

0~100 10 10 TACALG None

0~100 100 100 TACALG None

0~100 100 100 TACALG None

0~100 100 100 TACALG None

0~100 100 100 TACALG None


In the TACALG MO,
TRMULHOCACTH
must
In thebe larger than
TACALG MO,
0~100 90 90 TACALG In the TACALG MO,
or equal to
TRMULGOLDCAC
TRMDLHOCACTH
TRMULGOLDCAC
TH
mustmust
be be larger
larger than
0~100 90 90 TACALG TH.
In theor
than TACALG
equal toMO,
or equal to
TRMDLGOLDCAC
TRMULSILVERCA
TRMDLGOLDCAC
TH
CTH.must be larger
0~100 85 85 TACALG TH.
In theorTACALG
than equal toMO,
In the TACALG
TRMULSILVERCA MO,
TRMDLSILVERCA
TRMULHOCACTH
CTH
CTH. must be larger
0~100 85 85 TACALG must
In
than be
theor largertothan
TACALG
equal MO,
In
or the TACALG
equal to
TRMDLSILVERCA MO,
TRMULBRONZEC
TRMDLHOCACTH
TRMULGOLDCAC
CTH
ACTH. must be larger
0~100 85 85 TACALG must
TH.
than beequal
or largertothan
In
or the TACALG
equal to MO,
TRMDLBRONZEC
TRMULGOLDCAC
TRMDLGOLDCAC
ACTH.
0~100 85 85 TACALG TH
TH. must
In the
the be larger
TACALG MO,
In
than orTACALG
equal toMO,
TRMULSILVERCA
TRMDLGOLDCAC
TRMULSILVERCA
CTH mustbebelarger
larger
0~100 85 85 TACALG TH
CTH.
In must
the TACALG MO,
than
than or equal to
or equal to
TRMDLSILVERCA
TRMULBRONZEC
TRMDLSILVERCA
CTH must be larger
0~100 85 85 TACALG ACTH.
CTH.
than or equal to
TRMDLBRONZEC
ACTH.
0~100 100 100 TACALG None

0~100 100 100 TACALG None

OFF, ON OFF(Off) OFF(Off) TACALG None

OFF, ON OFF(Off) OFF(Off) TACALG None

OFF, ON ON(On) ON(On) TACALG None

OFF, ON ON(On) ON(On) TACALG None

OFF, ON OFF(Off) OFF(Off) TACALG None

OFF, ON OFF(Off) OFF(Off) TACALG None

FLOW_CTRL, NON_FLOW_CTRL
None TACALG None
NON_FLOW_CTRL (None Flow Control)
FLOW_CTRL, FLOW_CTRL(Flow
None TACALG None
NON_FLOW_CTRL Control)
FLOW_CTRL, FLOW_CTRL(Flow
None TACALG None
NON_FLOW_CTRL Control)
FLOW_CTRL, FLOW_CTRL(Flow
None TACALG None
NON_FLOW_CTRL Control)
FLOW_CTRL, FLOW_CTRL(Flow In the TLDRALG
None TACALG None
NON_FLOW_CTRL Control) MO, the value of
TRMULLDRTRGTH
0~100 70 70 TLDRALG In
In
must thebe
the TLDRALG
TLDRALG
larger than
MO,
MO,
that of the value of
TRMDLLDRTRGTH
TRMULLDRTRGTH
TRMULLDRCLRTH
0~100 70 70 TLDRALG In
must
must thebeTLDRALG
be larger
larger than
than
.
MO,
that of
TRMULLDRCLRTH
TRMDLLDRTRGTH
.TRMDLLDRCLRTH
In the TLDRALG
0~100 65 65 TLDRALG must
. thebe
MO, larger than
In TLDRALG
TRMDLLDRCLRTH
TRMULLDRCLRTH
MO,
In thebeTLDRALG
.TRMULLDRCLRTH
must larger than
0~100 65 65 TLDRALG MO,
In the
TRMULMLDTRGT
must be TLDRALG
larger than
TRMDLLDRCLRTH
MO,
H.
TRMULMLDTRGT
0~100 50 50 TLDRALG must
In be larger than
TRMDLLDRCLRTH
H. the TLDRALG
TRMDLMLDTRGT
must be larger than
MO,
H.
When
TRMDLMLDTRGT
TRMULMLDTRGT
0~100 50 50 TLDRALG In
In the
the TLDRALG
TLDRALG
TRMULOLCSWITC
H.
H must be larger
MO,
MO,
H in the TOLCALG
than
TRMULMLDTRGT
TRMDLMLDTRGT
MO is set
TRMULMLDCLRTH
In to ON,
the TLDRALG
0~100 45 45 TLDRALG H
H
the must
must be
QoSbe larger
of larger
high-
If
.than
MO,
than
priority services
TRMDLOLCSWITC
TRMDLMLDTRGT can
TRMULMLDCLRTH
TRMDLMLDCLRTH
be ensured in the
0~100 45 45 TLDRALG H in mustthebeTOLCALG
larger
.case
.thanisofsettransport
MO to ON,
overload
the QoS of
TRMDLMLDCLRTHin high-
the
OFF, ON ON(On) ON(On) TOLCALG uplink.
priority
. When
services can
TRMULOLCSWITC
be ensured. If
H in the TOLCALG
TRMDLOLCSWITC
OFF, ON ON(On) ON(On) TOLCALG MO
H in is set
the to OFF,
TOLCALG
the QoS
MO is setoftohigh-
OFF,
priority
the QoSservices
of high-
cannot be ensured
priority services
in the case
cannot be ensuredof
transport
in the case overload
of
in the uplink.
transport overload
in the downlink.
In
In the
the TOLCALG
TOLCALG
MO,
MO,
TRMULOLCRELTH
TRMULOLCTRIGT
0~100 95 95 TOLCALG must be smaller
H is valid only when
than
TRMULOLCSWITC
TRMULOLCTRIGT
H is set to ON.
0~100 90 90 TOLCALG
H.
In the TOLCALG
In the TOLCALG
0~100 5 5 TOLCALG MO,
None this parameter
MO,
In the TOLCALG
is valid only when
TRMDLOLCRELTH
MO, this parameter
TRMULOLCSWITC
0~100 95 95 TOLCALG must
is be smaller
H valid
is setonly when
to ON.
than
TRMDLOLCSWITC
TRMDLOLCTRIGT
H is set to ON.
0~100 90 90 TOLCALG H.
In the TOLCALG
WHITELIST, WHITELIST(Whiteli WHITELIST(Whiteli MO,
TRANSPORT None
TRMDLOLCRELTH
BLACKLIST st) st)
is valid only when
0~3 None None VLANCLASS TRMDLOLCSWITC
None
H is set to ON.
USERDATA, SIG,
OTHER, It is recommended
None None VLANCLASS None
OM_HIGH, that the value of In the VLANCLASS
OM_LOW this parameter be MO, this parameter
0~63 0 consistent with the VLANCLASS is valid only when
implementation of TRAFFIC is set to
the differentiated USERDATA.
NEXTHOPIP in the
1~4094 None None
service. VLANCLASS None
VLANMAP
In the binaryMO value
must be setMASK
into which to a in
0~7 0 0 VLANCLASS valid
the
None IP addressMO
VLANMAP of
Class
is converted, 0 In
A, B, or C.
addition,
cannot it cannot
precede 1.
Valid IP address None None VLANMAP beaddition,
In set to 127.x.x.x
the
or 0.x.x.x.
binary
VLANPRIO valuemust can be be
NEXTHOPIP
set to the same in
Valid Mask address 255.255.255.255 None VLANMAP each VLANMAP
255.255.255.255,
value
This for all
parameter
MO
but must
cannot
VLANMAP
must be set bebe
MOsonset
to aa to
SINGLEVLAN, unique
0.0.0.0.
whose network
VLANMODE
None None VLANMAP valid value when
VLANGROUP segments.
In
is the VLANMAP
theset to
VLANMAP MO
MO,thethis
the
SINGLEVLAN.
is being
In parameter
logical
modified.
VLANMAP
1~4094 None None VLANMAP is
ANDvalid
This
MO, only
result
parameter
this ofwhen
parameter is
VLANMODE
NEXTHOPIP
valid when the
is valid only when is
andset
to SINGLEVLAN.
MASK
VLANMAP
VLANMODE cannot MO isbeis 0.
set
0~7 0 0 VLANMAP
being modified
to VLANGROUP. and
SETPRIO
This parameteris is
0~3 None None VLANMAP changed
valid when fromthe
In the VLANMAP
DISABLE
VLANMAP toMO is
MO, this
ENABLE. parameter
being modified and
DISABLE, ENABLE ENABLE(Enable) DISABLE(Disable) VLANMAP is
In valid only when
the VLANMAP
VLANMODE is
VLANMODE fromis set
MO, this parameter
changed
to SINGLEVLAN.
is valid
SINGLEVLANonly when to
VLANMODE
VLANGROUP. is set
to SINGLEVLAN.
Service
Interruption
Access Interrupted After Interruption Scope Caution
Duration (min)
Modification
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) If the ALD power
No (And no impact supply switch is
Read & Write on the UE in idle Not involved Not involved OFF, the running of
mode) the ALD may be
No (And no impact affected.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
The cells carried on
Till unblocking is
Read & Write Yes the BBP are None
performed
unavailable.
The cells carried on
Read & Write Yes <2 None
the boards.

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read & Write Yes eNodeB <3 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes eNodeB <3 None
Read & Write Yes eNodeB <3 None
When the automatic
Read & Write Yes eNodeB power
<3 control None
switch is turned on,
When the automatic
the services of a
Read & Write Yes eNodeB power
cell arecontrol
interrupted None
switch
from the is automatic
turned on,
the services
power-off time of to
a
Read & Write Yes eNodeB cell are interrupted
the next automatic None
from the automatic
power-on time.
No (And no impact power-off time to
Read & Write on the UE in idle Not involved Not involved
the next automatic None
mode) power-on time.
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


The cells carried on
Till unblocking is
Read & Write Yes the RRU or RFU is None
performed
unavailable.
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
The cells carried on
Read & Write Yes the RRU are <1 None
unavailable.
The cells carried on
Till unblocking is
Read & Write Yes the RRU or RFU is None
performed
unavailable.
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
The cells carried on
Read & Write Yes the RRU are <1 None
unavailable.
The cells carried on
Till unblocking is
Read & Write Yes the RRU or RFU is None
performed
unavailable.
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read & Write Yes Cell <1 None

Cells carried on the


Read & Write Yes <1 None
RRU chain/ring
Cells carried on the
Read & Write Yes <1 None
RRU chain/ring
Cells carried on the
Read & Write Yes <1 None
RRU chain/ring
Cells carried on the
Read & Write Yes <1 None
RRU chain/ring
Cells carried on the
Read & Write Yes <1 None
RRU chain/ring
Cells carried on the
Read & Write Yes <1 None
RRU chain/ring
Cells carried on the
Read & Write Yes <1 None
RRU chain/ring
Cells carried on the
Read & Write Yes The <1 None
RRUcells covered
chain/ring
by the RRU
Cells
betweencarried
two on the
Read & Write Yes The cells covered <1 None
RRU chain/ring
breakpoints on a
by
ringthe
areRRU
Read & Write Yes between
unavailable,twoand <1 None
breakpoints on a by
the cells covered
ring are
the RRU after the
Read & Write Yes unavailable,
breakpoint onand a <1 None
the
chaincells
arecovered by
the RRU after the
unavailable.
Read Only Not involved Not involved
breakpoint on a Not involved Not involved
chain are
Read Only Not involved unavailable.
Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None


Services on the When the logical
Read & Write Yes channel are switch of RX None
affected. channel is ON
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None


Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None

Read & Write Yes Cell <1 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None


Services on the When the logical
Read & Write Yes channel are switch of TX None
affected. channel is ON
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved The


Nonemodification of
priorities will affect
No (And no impact the selection order
Read & Write on the UE in idle Not involved Not involved if the clock source
mode) is selected
automatically by the
Read Only Not involved Not involved Not involved Not involved
system.

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved The modification of
Not involved
priorities will affect
No (And no impact the selection order
Read & Write on the UE in idle Not involved Not involved when the clock
mode) source is selected
automatically by the
Read Only Not involved Not involved Not involved None
system.

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Only the TOD clock
of input type can
Read Only Not involved Not involved Not involved
serve as a clock
source.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact The clock accuracy
Read & Write on the UE in idle Not involved Not involved is affected if there is
None
mode) an excessively
No (And no impact large difference
Read & Write on the UE in idle Not involved Not involved (about 20 m)
mode) between the value
of this parameter
Read Only Not involved Not involved Not involved None
and the actual
feeder length.
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved The modification of
Not involved
priorities will affect
No (And no impact the selection order
Read & Write on the UE in idle Not involved Not involved when the clock
mode) source is selected
automatically by the
Read Only Not involved Not involved Not involved None
system.

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) The clock accuracy
No (And no impact
Read & Write on the UE in idle Not involved Not involved is affected if there is
None
mode) an excessively
No (And no impact large difference (no
Read & Write on the UE in idle Not involved Not involved less than 20 m)
mode) between the value
of this parameter
Read Only Not involved Not involved Not involved None
and the actual
feeder length.
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
Read Only Not involved Not involved Not involved When the clock
Not involved
source is selected
No (And no impact automatically by the
Read & Write on the UE in idle Not involved Not involved system, the
mode) modification of
priorities will affect
Read Only Not involved Not involved Not involved None
the selection order.

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
The parameter
should be
Read Only Not involved Not involved Not involved consistent with
configuration of the
No (And no impact server domain.
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved The
Nonemodification of
priorities will affect
No (And no impact the selection order
Read Only on the UE in idle Not involved Not involved when the clock
mode) source is selected
No (And no impact automatically by the
Read Only on the UE in idle Not involved Not involved Not involved
system.
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved The modification of
Not involved
priorities will affect
No (And no impact the selection order
Read & Write on the UE in idle Not involved Not involved when the clock
mode) source is selected
automatically by the
Read Only Not involved Not involved Not involved Not involved
system.

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services of the cells
The cells are resume after the
Read & Write Yes None
unavailable. clock source is
locked again.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
If the clock quality
Read Only Not involved level of the clock
Not involved Not involved Not involved
source is greater
than that is set by
Until the clock
Read & Write Yes this parameter at None
source is qualified
the local end, the
clock source
Read Only Not involved Not involved
becomes Not involved Not involved
unavailable.
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
If the manager is
not specified, the
Read Only Not involved Not involved Not involved EMU cannot be
If the manager
operated or is
not specified,
maintained. the
Read Only Not involved Not involved Not involved EMU
If the cannot
actual be
operated
connection oris
No (And no impact maintained.
inconsistent
The with
communication
Read & Write on the UE in idle Not involved Not involved
the configuration,
address of the EMU
mode)
No (And no impact the EMU cannot
is usually 2. If it isbe
Read & Write on the UE in idle Not involved Not involved maintained.
not 2, set it
mode) according to the
No (And no impact physical DIP switch
Read & Write on the UE in idle Not involved Not involved None
settings.
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
If the manager is
not specified, the
Read Only Not involved Not involved Not involved FMU cannot be
If the manager
operated or is
not specified,
maintained. the
Read Only Not involved Not involved Not involved FMU cannot be
The communication
operated or
No (And no impact address of the FMU
maintained.
Read & Write on the UE in idle Not involved Not involved None
is usually 14. If it is
mode) not 14, set it
No (And no impact
according to the
Read & Write on the UE in idle Not involved Not involved
settings of physical
mode)
No (And no impact DIP switch.
Read & Write on the UE in idle Not involved Not involved Otherwise,
None the
mode) communication with
the FMU fails.
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


The FMU cannot be
operated or
Read Only Not involved Not involved Not involved maintained if no
manager is
specified.
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved
If the manager is
not specified, the
Read Only Not involved Not involved Not involved TCU cannot be
If the manager
operated or is
not specified, the
maintained.
Read Only Not involved Not involved Not involved TCU
If the cannot
actual be
operated oris
connection
No (And no impact maintained.
inconsistent with
The communication
Read & Write on the UE in idle Not involved Not involved
the configuration,
address of the TCU
mode)
No (And no impact theusually
is TCU cannot be
7. If it is
Read & Write on the UE in idle Not involved Not involved maintained.
not 7, set it
mode) according to the
No (And no impact physical DIP switch
Read & Write on the UE in idle Not involved Not involved None
settings.
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
If the manager is
not specified, the
Read Only Not involved Not involved Not involved PMU cannot be
If the manager
operated or is
not specified,
maintained. the
Read Only Not involved Not involved Not involved PMU
If the cannot
actual be
operated
connection oris
No (And no impact The communication
maintained.
inconsistent with
Read & Write on the UE in idle Not involved Not involved address must be
the configuration,
mode) consistent with the
No (And no impact the PMU cannot be
DIP
maintained.settings
switch
Read & Write on the UE in idle Not involved Not involved
on the PMU.
mode)
Otherwise, the
Read Only Not involved Not involved Not involved communication
Not involved
fails.
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
The INSTALLTYPE
No (And no impact of the SC48200
Read & Write on the UE in idle Not involved Not involved PMU is set to
mode) The
OUTERbattery
only.ofDo
the
No (And no impact SC48200
not modify it. is
PMU
Read & Write on the UE in idle Not involved Not involved not related to this
mode) parameter. Do not
No (And no impact modify it.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes eNodeB 3 None

Read & Write Yes eNodeB 3 None

Read & Write Yes eNodeB 3 None

Read Only Not involved Not involved Not involved None

Read & Write Yes eNodeB 3 None

Read & Write Yes eNodeB 3 None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes eNodeB 3 None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None


No (After an S1
interface is blocked,
Read & Write UEs in idle mode Not involved Not involved None
fail to access the
network.)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read & Write Yes eNodeB 0.1 None

Read & Write Yes eNodeB 0.1 None

Read & Write Yes eNodeB 0.1 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (no impact on
Read Only the
Not UE in idle
involved Not involved Not involved None
mode. This
No (For theisUE
parameter used in
Read & Write idle mode,
with other if it is Not involved Not involved None
BOOLEAN_TRUE,
No (The access
parameters related
the emergency
request
to cell of the calls
access
Read & Write initiated
barring tobycontrol
mobile-originated the UEs Not involved Not involved None
No
of (For the UE by ain
theaccess
call initiated
UE accesses.)
idle mode,
categories
UE in idle mode the
0 to 9isor
Read & Write mobile-originated
UEs without Not involved Not involved None
accepted or IMSI
call accesses
are rejected.)
rejected accordingare
allowed
to the only if the
Read & Write Not involved Not involved None
random
corresponding
No number
(And no impact
generated
No (And
barring
on the UE by
noin the
impact
status.) idle
Read & Write UE
mode. If this the
on is
the less
UE than
in idle Not involved Not involved None
access
No
mode) (Andprobability
parameter noisimpact
set to
factor.)
on the UE
BOOLEAN_TRUE, in idle
Read & Write mode. If this Not involved Not involved None
the mobile-
parameter
originated callsis set to
BOOLEAN_TRUE,
initiated by UEs of
Read & Write Not involved Not involved None
the
accessmobile-
class 11 are
originated
not allowed.) calls
initiated by UEs of
access class 12 are
not allowed.)
No (And no impact
on the UE in idle
mode. If this
No (And noisimpact
parameter set to
on the UE in idle
BOOLEAN_TRUE,
Read & Write mode. If this Not involved Not involved None
the mobile-
No (And noisimpact
parameter
originated set to
on the UE calls
BOOLEAN_TRUE, in idle
Read & Write initiated
mode. If by
thisUEs of Not involved Not involved None
the
accessmobile-class 13 are
parameter
No (The access
originated is set
calls to
not allowed.)
BOOLEAN_TRUE,
Read & Write request of
initiated by UEs ofthe Not involved Not involved None
the
accessmobile-
signaling initiated
class 14 are
No (For
UE the
originated
by UE in
in calls
notaallowed.) idle
Read & Write idle
mode mode,
initiated is by the
UEs of
accepted Not involved Not involved None
signaling
access
or rejected accesses
class 15 are
are allowedtoonly
not allowed.)
according the if
Read & Write the random number
corresponding Not involved Not involved None
generated
barring
No (And by
status.)
no the
impact
No
UE (And
is less nothan
impact
the
Read & Write on
on the
the UE UE in
in idle
idle Not involved Not involved None
access
mode. probability
If this
mode)
factor.)
No (And noisimpact
parameter set to
Read & Write on the UE in idle
BOOLEAN_TRUE, Not involved Not involved None
mode.
the If this
signaling
No (And
parameter noisimpact
set to
access
on the initiated
UE in idleby
Read & Write BOOLEAN_TRUE,
UEs of Ifaccess Not involved Not involved None
mode.
the signalingthis class
11
No are
(And
parameter notnoallowed.)
isimpact
set to
access
on the initiated
UE in idleby
Read & Write BOOLEAN_TRUE,
UEs of Ifaccess Not involved Not involved None
mode.
the signalingthis class
12
No are
(And
parameter not noallowed.)
isimpact
set to
access
on the initiated
UE in idleby
Read & Write BOOLEAN_TRUE,
UEs of Ifaccess Not involved Not involved None
mode.
the signalingthis class
13 are
parameter not allowed.)
is setby to
access initiated
Read & Write BOOLEAN_TRUE,
UEs of access class Not involved Not involved None
the
14 aresignaling
not allowed.)
access initiated by
Read Only Not
UEs involved
of access class Not involved Not involved None
No (Modifications
15
on this not
are allowed.)
parameter
Read & Write will affect the cell on Not involved Not involved None
No
which(Modifications
the UE in idle
on this parameter
mode camps.)
Read & Write will affect the cell on Not involved Not involved None
No
which(Modifications
the UE in idle
on
modethiscamps.)
parameter
Read & Write will affect the cell on Not involved Not involved None
No
which(Modifications
the UE in idle
on this parameter
mode camps.)
Read & Write will affect the cell on Not involved Not involved None
No
which(Modifications
the UE in idle
on
modethiscamps.)
parameter
Read & Write will affect the cell on Not involved Not involved None
which the UE in idle
mode camps.)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None


No (Modifications
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
UE in idle mode.)
No (Modifications
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
UE in idle mode.)
Read Only Not involved Not involved Not involved None
No (Modifications
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
UE in idle mode.)
No (Modifications
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
UE in idle mode.)
Read Only Not involved Not involved Not involved None
No (Modifications
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
UE in idle mode.)
Read Only Not involved Not involved Not involved None
No (Modifications
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
UE in idle mode.)
Read Only Not involved Not involved Not involved None
No (Modifications
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
UE in idle mode.)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None


Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Until the cell is
Read & Write Yes Cell None
activated
Until the cell is
Read & Write Yes Cell None
unblocked
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None

Read & Write None None None None

Read & Write None None None None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None


Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None

Read & Write Yes Cell 0.1 None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read & Write Yes Cell 0.1 None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
No (Modifications
mode)
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
No
UE (And
in idleno impact
mode.)
Read & Write on the UE in idle Not involved Not involved None
No (Modifications
mode)
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
UE in idle mode.)
No (Modifications
on this parameter
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on
UEthis parameter
in idle mode.)
Read & Write would affect cell Not involved Not involved None
No (Modifications
reselection of the
on this parameter
UE in idle mode.)
Read & Write would affect cell Not involved Not involved None
reselection of the
No
UE (And
in idleno impact
mode.)
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read & Write Yes Cell 0.1 None
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Less than one


Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Less than one


Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute

Read Only Not involved Not involved Not involved Not involved

Less than one


Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Read Only Not involved Not involved Not involved Not involved

Less than one


Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute

Read Only Not involved Not involved Not involved Not involved

Less than one


Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute
Less than one
Read & Write Yes NE None
minute

Read & Write Yes eNodeB Less than 1 minute None


No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read Only on the UE in idle Not involved Not involved Not involved
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
The service
continues to be
Read & Write Yes BS interrupted until the None
The serviceis
parameter
continues to be
correctly set.
Read & Write Yes BS interrupted until the None
parameter is
correctly set.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved
The service
continues to be
Read & Write Yes BS interrupted until the None
The serviceis
parameter
continues to be
correctly set.
Read & Write Yes BS interrupted until the None
parameter is
correctly set.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Less than one


Read & Write Yes BS None
minute
Less than one
Read & Write Yes BS None
minute

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
The MANAME
value of each CFM
Read Only Not involved Not involved Not involved
MA must be unique
in a CFM MD.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
Services are
correctly set.
interrupted until the
Read & Write Yes BS None
parameter is
Services are
correctly set.
interrupted until the
Read & Write Yes BS None
parameter is
Services are
correctly set.
interrupted until the
Read & Write Yes BS None
parameter is
Services are
correctly set.
interrupted until the
Read & Write Yes BS None
parameter is
No (And no impact correctly set.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
No (And no impact correctly set.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
No (And no impact correctly set.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
No (And no impact correctly set.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
No (And no impact correctly set.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
No (And no impact correctly set.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
No (And no impact correctly set.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
correctly set.
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) Services are
interrupted until the
Read & Write Yes BS None
parameter is
No (And no impact correctly set.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Less than 10
Read & Write Yes BS None
minutes
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
All the services
Read & Write Yes 1 None
carried on the port
All the services
Read & Write Yes 1 None
carried on the port
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

All the services


Read & Write Yes 1 None
carried on the port
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

All the services


Read & Write Yes 1 None
carried on the port

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode) The service
continues to be
Read & Write Yes BS interrupted until the None
parameter is
correctly set.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved The
Nonesetting of this
mode) parameter must be
No (And no impact consistent with that
Read & Write on the UE in idle Not involved Not involved at the peer NE.
mode) Modifications
This parameter on
No (And no impact this parameter are
must be set to the
Read & Write on the UE in idle Not involved Not involved not allowed.
same value as that
mode) The value
No (And no impact at the
This peerofNE.
parameter
this
parameter must be
Read & Write on the UE in idle Not involved Not involved value mustasbethat
theat
the same
mode) same as the peer IP
No (And no impact the peer NE.
address.
The
Read & Write on the UE in idle Not involved Not involved
Modifications on
REMOTENAME
mode)
No (And no impact this
valueparameter
of the IKE
Read & Write on the UE in idle Not involved Not involved value
peer isare
casenot
mode) allowed.
insensitive
The value of andthis
No (And no impact cannot
parameter mustnon-
contain be
Read & Write on the UE in idle Not involved Not involved ASCII characters.
the same as that at
mode)
No (And no impact the peer NE.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
The value of this
No (And no impact
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode)
the peer NE.
The value of this
No (And no impact
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode) The valueNE.
of this
No (And no impact the peer
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode) The valueNE.
of this
No (And no impact the peer
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode)
No (And no impact the peer NE.
Read & Write on the UE in idle Not involved Not involved None
mode) The value of this
No (And no impact
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode)
the peer NE.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read & Write Yes BS Less than 1 minute None

Read & Write Yes BS Less than 1 minute None

Read & Write Yes BS Less than 1 minute None

Less than one


Read & Write Yes BS None
minute
Less than one
Read & Write Yes BS None
minute
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Less than one
Read & Write Yes BS None
minute
Less than one
Read & Write Yes BS None
minute
Less than one
Read & Write Yes BS None
minute
Less than one
Read & Write Yes BS None
minute
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Less than one
Read & Write Yes BS None
minute
The services If this parameter is
continues to be set to DISABLE, the
Interface S1 and
Read & Write Yes disrupted until the connectivity of an IP
services in the cell
path detection is path cannot be
stopped. checked.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Less than one


Read & Write Yes BS None
minute
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Less than one
Read & Write Yes BS None
minute
Less than one
Read & Write Yes BS None
minute

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
When this
Read Only Not involved Not involved Not involved parameter
Not involvedis set to
BIDIR, the IP PM
session resource at
Read Only Not involved Not involved Not involved Not involved
the peer end is
occupied. During
the current session,
Read Only Not involved Not involved Not involved
another IP PM
session with the
Read Only Not involved Not involved Not involved same DSCP that is
Not involved
established on the
same IP path
Read Only Not involved Not involved Not involved Not involved
cannot be activated
at the peer end.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved The SPGN value is
Not involved
case insensitive.
When the SPGN
Read Only Not involved Not involved Not involved Not
valueinvolved
is referenced,
however, the name
of the policy group
Read Only Not involved Not involved Not involved
must be exactly the
same as the
Read Only Not involved Not involved Not involved configured
Not involved one.
Otherwise, the
No (And no impact related operation
Read & Write on the UE in idle Not involved Not involved None
fails.
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
The value of this
No (And no impact
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode)
No (And no impact the peer NE.
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

The referenced
Read Only Not involved Not involved Not involved Not involved
value of this
parameter must be
exactly the same as
Read Only Not involved Not involved Not involved
the configured
The
name.value of this
Otherwise,
No (And no impact
parameter
the related must be
Read & Write on the UE in idle Not involved Not involved
the same as
operation that at
fails.
mode) The valueNE.
of this
No (And no impact the peer
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode) The valueNE.
of this
No (And no impact the peer
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode) The valueNE.
of this
No (And no impact the peer
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode) The valueNE.
of this
No (And no impact the peer
parameter must be
Read & Write on the UE in idle Not involved Not involved
the same as that at
mode)
the peer NE.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
The password must
not contain the
Read Only Not involved Not involved Not involved following
characters: <,
>, !, ?, and :.
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Less than one


Read & Write Yes BS None
minute
Less than one
Read & Write Yes BS None
minute

Read & Write Yes BS Less than 1 minute None

Less than one


Read & Write Yes BS None
minute
Less than one
Read & Write Yes BS None
minute

Read & Write Yes BS Less than 1 minute None

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved Modifying
None the
mode) parameter setting
Services are from FLOW_CTRL
Services of user Modifying the
Read & Write Yes interrupted until to
data type 5 parameter setting
readmission. NON_FLOW_CTRL
Services are from
may FLOW_CTRL
interrupt
Read & Write Yes
Services of user
interrupted until Modifying
to the this
data type 6 type of service.
parameter setting
readmission. NON_FLOW_CTRL
Services are from
may FLOW_CTRL
interrupt
Read & Write Yes
Services of user
interrupted until Modifying
to the this
data type 7 type of service.
parameter setting
readmission. NON_FLOW_CTRL
Services are from
may FLOW_CTRL
interrupt
Read & Write Yes
Services of user
interrupted until Modifying
to the this
data type 8 type of service.
parameter setting
readmission. NON_FLOW_CTRL
Services are from FLOW_CTRL
may interrupt this
Services of user
Read & Write Yes interrupted until to
type of service.
data type 9
readmission. NON_FLOW_CTRL
No (And no impact may interrupt this
Read & Write on the UE in idle Not involved Not involved None
type of service.
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Read Only Not involved Not involved Not involved Not involved

Read Only Not involved Not involved Not involved Not involved
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
No (And no impact
Read & Write on the UE in idle Not involved Not involved None
mode)
Impact on Radio
Validation of Introduced in Initial Value
Network Attribute
Modification Version... Setting Source
Performance
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning
The parameter
modification has no
None V100R001C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no
None V100R001C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no
None V100R001C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
When this
parameter is set to
The parameter NORMAL, the TMA
modification has no can work properly
None V100R001C00 Equipment Radio Planning
impact on the to improve the
The parameter
equipment. signal-to-noise ratio
modification has no Default/Recommen
and sensitivity of V100R001C00 Equipment
impact on the ded
the eNodeB.
equipment.
When this Equipment
Not involved None
parameter is set to V100R001C00 Equipment
Planning
BYPASS, the TMA
does Equipment
Not involved None not amplify V100R001C00 Equipment
any uplink signal. Planning
Equipment
Not involved None V100R001C00 Equipment
Planning
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the
The parameter ded
equipment. takes
modification
Equipment
effect after the None V100R001C00 Equipment
Planning
board is
automatically reset.
Not involved None V100R002C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Not involved None V100R003C00 Equipment Not involved
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


The BS should be
reset to validate the
None V100R001C00 Equipment Radio Planning
parameter
The parameter
modification.
modification has no
None V100R001C00 Equipment Radio Planning
impact on the
The BS should be
equipment.
reset to validate the
None V100R001C00 Equipment Radio Planning
parameter
modification.
The BS should be
reset to validate the
None V100R001C00 Equipment Radio Planning
parameter
The BS should be
modification.
reset to validate the Equipment
None V100R001C00 Equipment
parameter Planning
The parameter
modification.
modification has no
None V100R001C01 Equipment Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Equipment Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Equipment Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Equipment Radio Planning
impact on the
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


The parameter
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no Equipment
None V100R003C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
equipment.
Equipment
Not involved None V100R001C01 Equipment
Planning
The parameter
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Equipment
impact on the ded
equipment.
Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning
Equipment
Not involved None V100R001C00 Equipment
Planning

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


The parameter
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
The board should
be reset to validate Equipment
None V100R001C01 Equipment
the parameter Planning
The parameter
modification.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
equipment.
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


The parameter
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Equipment
Not involved None V100R001C00 Equipment
Planning
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The board should
equipment.
be reset to validate Equipment
None V100R001C01 Equipment
the parameter Planning
The parameter
modification.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
equipment.
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


The parameter
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Equipment
Not involved None V100R001C01 Equipment
The parameter Planning
modification takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
Planning
is
Theautomatically
BS should be
reset.
reset to validate the Equipment
None V100R001C01 Equipment
parameter Planning
The BS should be
modification.
reset to validate the Equipment
None V100R001C01 Equipment
parameter Planning
The BS should be
modification.
reset to validate the Equipment
None V100R001C01 Equipment
parameter Planning
The BS should be
modification.
reset to validate the Equipment
None V100R001C01 Equipment
parameter Planning
The BS should be
modification.
reset to validate the Equipment
None V100R001C01 Equipment
parameter Planning
The BS should be
modification.
reset to validate the Equipment
None V100R001C01 Equipment
parameter Planning
The BS should be
modification.
reset to validate the Equipment
None V100R001C01 Equipment
parameter Planning
The BS should be
modification.
reset to validate the Equipment
None V100R001C01 Equipment
parameter Planning
The parameter
modification.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
equipment.
Default/Recommen
Not involved None V100R002C00 Equipment
ded

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Radio Planning


The parameter
modification has no
None V100R001C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Equipment Radio Planning
impact on the
The parameter
equipment. takes
modification
effect after the cell None V100R001C00 Equipment Radio Planning
The parameter
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C00 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C00 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C00 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C00 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C00 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C00 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C00 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C00 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
Planning
is automatically
reset.
The parameter
modification takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
Equipment
effect after the cell None V100R001C01 Equipment
The parameter Planning
is automatically
modification
reset. takes
effect after the cell None V100R002C00 Equipment Radio Planning
is automatically
The parameter
reset.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
equipment.
The parameter
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Radio Planning
impact on the
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C01 Equipment
ded
Default/Recommen
Not involved None V100R001C01 Equipment
ded
Default/Recommen
Not involved None V100R001C01 Equipment
ded
Default/Recommen
Not involved None V100R001C01 Equipment
ded

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Default/Recommen
Not involved None V100R001C01 Equipment
ded

Not involved None V100R001C01 Equipment Not involved


Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Equipment
Not involved None V100R001C01 Equipment
Planning

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Default/Recommen
Not involved None V100R002C00 Equipment
ded

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Equipment
Not involved None V100R001C01 Equipment
Planning
Default/Recommen
Not involved None V100R001C01 Equipment
ded

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Equipment
Not involved None V100R001C01 Equipment
Planning
The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Equipment
Not involved None V100R001C01 Equipment
Planning

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


Not involved None V100R001C01 Equipment Not involved
The parameter
modification has no Equipment
Noneparameter
This V100R003C00 Equipment
impact on the Planning
The parameter
equipment. must be set based
modification has no The
on thefeeder delay
network Equipment
This
should parameter
be V100R001C01 Equipment
impact on the plan. Otherwise, the Planning
The parameter
equipment. must be set
calculated
precision based
of location
modification has no on the
accordingnetwork
to the
services is lowered. Equipment
V100R001C01 Equipment
impact on the plan. Otherwise,
actual length of thethe Planning
The parameter
equipment. precision
feeder. of location
Typically,
modification has no services
3.8 is lowered.
ns delay is Equipment
None V100R001C01 Equipment
impact on the generated when Planning
The parameter
equipment.
modification has no data passes one Equipment
None feeder. For
meter V100R002C00 Equipment
impact on the Planning
equipment. an LTE TDD cell
whose radius is less
Not involved V100R001C01 Equipment Not involved
than 3 km, the
The parameter delay must be less
modification has no then Equipment
None3 us; for an V100R003C00 Equipment
impact on the LTE TDD cell Planning
The parameter
equipment.
modification has no whose radius is Equipment
None
greater than 3 km, V100R003C00 Equipment
impact on the Planning
The parameter
equipment. the delay must be
modification has no less than 5 us. Equipment
None V100R002C00 Equipment
impact on the Otherwise, the Planning
The parameter
equipment. service
modification has no performance is Equipment
None V100R002C00 Equipment
impact on the affected. Planning
equipment.
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Not involved None V100R001C01 Equipment Not involved
Not involved None V100R001C01 Equipment Not involved
The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
equipment.
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R001C01 Equipment
Planning
Default/Recommen
Not involved None V100R001C01 Equipment
ded
The parameter
modification has no Default/Recommen
None V100R002C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Equipment
impact on the ded
equipment.
Not involved None V100R002C00 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Default/Recommen
Not involved None V100R001C01 Equipment
ded
Default/Recommen
Not involved None V100R001C01 Equipment
ded

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Equipment
Not involved None V100R001C01 Equipment
Planning
Equipment
Not involved None V100R003C00 Equipment
Planning
Equipment
Not involved None V100R003C00 Equipment
Planning
Equipment
Not involved None V100R003C00 Equipment
Planning

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C01 Equipment
ded
Default/Recommen
Not involved None V100R001C01 Equipment
ded
Default/Recommen
Not involved None V100R001C01 Equipment
ded
Default/Recommen
Not involved None V100R001C01 Equipment
ded
Equipment
Not involved None V100R001C01 Equipment
Planning
The parameter
modification has no Equipment
None V100R002C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


The parameter
modification has no
None V100R001C01 Equipment Not involved
impact on the
equipment.
Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C01 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Equipment
impact on the ded
The parameter
equipment.
modification has no
None V100R003C00 Equipment Not involved
impact on the
equipment.
Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved

Not involved None V100R001C01 Equipment Not involved


The parameter
modification has no
None V100R003C00 Equipment Not involved
impact on the
equipment.
Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R003C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R003C00 Equipment
impact on the Planning
equipment.
Equipment
Not involved None V100R003C00 Equipment
Planning
The parameter
modification has no Equipment
None V100R003C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R003C00 Equipment
impact on the Planning
equipment.
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R003C00 Equipment
impact on the Planning
equipment.
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no
None V100R003C00 Equipment Not involved
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Equipment Not involved
impact on the
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Equipment
Not involved None V100R001C00 Equipment
Planning
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no
None V100R001C00 Equipment Not involved
impact on the
equipment.
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no
None V100R003C00 Equipment Not involved
impact on the
equipment.
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved


Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no
None V100R003C00 Equipment Not involved
impact on the
equipment.
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
The parameter
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Default/Recommen
Not involved None V100R001C00 Equipment
ded
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved


Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R002C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R003C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R003C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Equipment
Not involved None V100R001C00 Equipment
Planning
The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no
None V100R001C00 Transport Not involved
impact on the
equipment.
Equipment
Not involved None V100R001C00 Equipment
Planning
The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Equipment
impact on the ded
equipment.
Default/Recommen
Not involved None V100R002C00 Equipment
ded
Equipment
Not involved None V100R002C00 Equipment
Planning
The parameter
modification has no Equipment
None V100R002C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R002C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R002C00 Equipment
impact on the Planning
equipment.
Not involved None V100R003C00 Equipment Not involved
The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
The parameter
equipment.
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved

Not involved None V100R001C00 Equipment Not involved


The parameter
modification has no Equipment
None V100R001C00 Equipment
impact on the Planning
equipment.
Not involved None V100R003C00 Equipment Not involved

Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R003C00 Radio Engineering Design


The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R003C00 Radio Engineering Design


The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R003C00 Radio Radio Planning
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R003C00 Radio Radio Planning


The parameter
modification has no
None V100R003C00 Radio Radio Planning
impact on the
equipment.
Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R003C00 Radio Engineering Design


The parameter
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
equipment.
Not involved None
If the values of V100R003C00 Radio Radio Planning
The parameter CounterCheckTimer
modification has no and
None
If the values of V100R003C00 Radio Radio Planning
impact on the CounterCheckCoun
The parameter
equipment. CounterCheckTimer
tNum are too small,
modification has no and
the counter check
None V100R003C00 Radio Radio Planning
impact on the CounterCheckCoun
procedures are
The parameter
equipment. tNum are too
modification has no performed toosmall,
the
None counter
frequently, check
which V100R003C00 Radio Radio Planning
impact on the procedures are
The parameter
equipment. wastes
If radio
this parameter is
modification has no performed
resources. too
If DRB
the is Default/Recommen
set to ON,
frequently, a
which V100R001C01 Radio
impact on the values
released arewhentoo the ded
The parameter
equipment. wastes
large, theradio
counter
modification has no counter
resources. check If the Default/Recommen
check
detects procedure
an too V100R001C01 Radio
impact on the values
fails are
to be initiated ded
The parameter
equipment. exception
large, the in the
counter
modification has no during
DRB. athis
If long
check
period, procedure
which V100R001C01 Radio Engineering Design
impact on the parameter
fails to be is set to
The parameter
equipment. causes
OFF, a theinitiated
DRB failure
is not
modification has no during
to check a long
the HFN
released
None which if the
period, even V100R003C00 Radio Engineering Design
impact on the on the
counter UE checkside and
The parameter
equipment. causes
that on the
the failure
eNodeB
modification has no detects
to checkan the HFN
side.
None
exception V100R003C00 Radio Engineering Design
impact on the on the UE in sidetheand
The parameter
equipment. DRB.
that on the eNodeB
modification has no side.
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
The parameter If this parameter is
modification has no set to
none
LCG_PROFILE_1, V100R001C01 Radio Engineering Design
impact on the If SRI adaptation is
The parameter
equipment. non-GBR services
enabled, the
modification has no are classified into
capacity of users V100R003C00 Radio Engineering Design
impact on the high- and low-
The parameter sending
After T320
ROHC SRIs
helps expires,is
reduce
equipment. priority non-GBR
modification has no relatively
the
header dedicated large.
overhead.
services.
priorities QoS of
indicated V100R003C00 Radio Engineering Design
impact on the The compression
The parameter high-priority
in the non-
equipment. efficiency is is
modification has no GBR services
RRCConnectionRel
especially
better ensured, but V100R003C00 Radio Engineering Design
impact on the Packet
ease transmission
message
The parameter significant
there for of
is ainvalid,
risk
equipment. reliability
become and the and
modification has no services
If the value
failure with
tolink ofsmall
maintain this
network
the
data absolute
parameterpackets, is too such V100R001C01 Radio Engineering Design
impact on the QoS of low-priority
The parameter overhead
priorities
After
as
small,VoIPT320
the are
indicated
expires,
services.
eNodeB
equipment. non-GBR
The support services.
for
modification has no affected.
in
the
may the system
dedicated
reject access is
different
information
priorities protocols
take for V100R001C01 Radio Engineering Design
impact on the of the UEindicated
affected. again
The parameter effect.
in As the
equipment. thethe same reason. If
modification has no absolute UE priorities Default/Recommen
RRCConnectionRel
If
thethe value is toonot in
does V100R001C00 Radio
impact on the the
ease system
complete message ded
The parameter large, the an UEintra- may
equipment. information
become invalid,are
modification has no RAT
fail tohandover
access theand Default/Recommen
If
thethe
optional,
before UE
absolute
this does
frequency
timer not V100R002C00 Radio
impact on the network for a long ded
The parameter complete
prioritization
priorities
expires, an
indicated
the inter-
UE be
can
equipment. period, which
modification has no RAT
better
in the
reverts handover
back to to
guaranteed
system the Default/Recommen
affects user V100R001C00 Radio
impact on the GERAN
during
information
associated before
cell takethis ded
experience.
If the expires,
UE
The parameter
equipment. timer
reselection
effect. As inactivity
configuration the if thethe
and
modification has no timer
UE is
revertsnot used,
back
dedicated
absolute
initiates an RRC toin
priorities
priorities V100R001C00 Radio
Default/Recommen
impact on the the
are
the UE
used. remains
associated
system re- If the ded
The parameter connection
equipment. connected
configuration to the
modification has no establishmentand
value
informationof this are
Default/Recommen
network
initiates
parameter
optional, even
an isRRC
frequency if it
too V100R002C00 Radio
impact on the procedure. ded
has been
connection
large, cell can be
prioritization in idle
re-
The parameter
equipment. mode for
establishment
reselection
better a long
guaranteed
modification has no Default/Recommen
period.
procedure.
parameters If the
during cell cannot timer V100R001C00 Radio
impact on the ded
The parameter is
beused,
updated
reselection theifin radio
thetime
equipment.
modification has no resources
at the
dedicated UE for the
when
priorities
None
UE are released V100R003C00 Radio Engineering Design
impact on the priority
are used. valuesIf the if it
The parameter is in idle
equipment. change.
value of this for a
mode
modification has no duration exceeding
parameter
None is too V100R003C00 Radio Engineering Design
impact on the the length
The parameter large, cell of this
equipment. timer.
modification has no reselection
None
parameters cannot V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment. be updated in time
modification has no at the UE when
None V100R003C00 Radio Engineering Design
impact on the priority values
The parameter
equipment. change.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None
If the RS power is V100R003C00 Radio Engineering Design
impact on the
fixed, setting the
equipment.
value of this
Not involved None
parameter too V100R002C00 Radio Radio Planning
If this switch is high
on,
The parameter increases the
the PA is adjusted.
modification has no power and MCS of
If this switch is off, V100R002C00 Radio Engineering Design
impact on the all
The parameter theusers
PA is in
notthe cell,
equipment. but may result in
modification has no adjusted.
power limitation, V100R002C00 Radio Engineering Design
impact on the
which affects the
equipment.
cell throughput.
Not involved None the value of
Setting V100R003C00 Radio Radio Planning
The parameter this parameter too
modification has no low decreases the Default/Recommen
None V100R003C00 Radio
impact on the power and MCS ded
equipment. and reduces the
cell throughput.
The parameter
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None
If the value V100R003C00 Radio
impact on the When Ks is of equalthis to ded
The parameter
equipment. parameter is too
0, the transmit
modification has no small, the Default/Recommen
None
power
If the valuecantransmit
be this V100R003C00 Radio
impact on the power
adjusted of theofSRS is ded
The parameter
equipment. parameter is toothe
too low,
according so that
to only
modification has no small, the transmit Default/Recommen
None
uplink
closed-loop timing V100R003C00 Radio
impact on the power
requirement of theTPC SRS
is not is
ded
equipment. commands.
too low, so When
that the
met
Ks and
is equal the SINR
to 1.25,
Not involved none
uplink
of data timing
channels V100R001C01 Radio Radio Planning
the
A transmit
greater
requirement value power
is notof
The parameter cannot be
can
this
met be adjusted
parameter
and the SINR by
modification has no measured
means
indicates
of of
data channelsaselecting
greater V100R001C01 Radio Engineering Design
impact on the accurately. Thus,
The parameter different
impact of
cannot bethe
equipment. the network
modification has no MCSs
previous
measured during
RSRP
performance
scheduling.
value on theThus, This
filtered V100R001C01 Radio Engineering Design
impact on the accurately.
The parameter deteriorates.
helps
value
DRX the
and UE
introduces a Iftothe
smaller
equipment. the network
modification has no value
quickly
impact
extra of of
delaythis
adapt
the to
toRSRP
performance
parameter is too V100R001C01 Radio Engineering Design
impact on the changes
value measured
scheduling.
The parameter deteriorates.
large, theon If
transmit the
equipment. in
thischannel
time
Therefore, ifthe
a UE
modification has no value
power ofof this
the SRS
conditions
filtered
with value.
a service
parameter and
ishigh,
tooA is V100R001C01 Radio Engineering Design
impact on the excessively
increases
smaller
whose
large, value
QCI
the the is of
transmit cellthis
equipment. which increases the
throughput.
parameter
mapped
power to
of the toindicates
a high
SRS is
Not involved interference
None
a smaller impact
requirement for the of V100R003C00 Radio Radio Planning
excessively
other channels high, and
the
delay
which previous
is allowed
increases RSRP to
the
neighboring
value
enter on the
the DRX cells
filtered
Not involved interference
None
and thus reduces to V100R003C00 Radio Engineering Design
value
state,
other and
the a
QoS
channels of greaterand
The parameter the throughput
impact
satisfaction
If this of therate
parameter
neighboring RSRP
cells is
modification has no the entire network.
value
may
set
and to measured
decrease
thusa small
reduces value, V100R003C00 Radio Engineering Design
impact on the
The parameter this
because
the
the UE timemay
throughputon
of the the
enter of
equipment.
modification has no filtered
increase
Sleep
the value.
Time
entire in the
before
network.
None
delay of the
receiving theservice. V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment. If a UE with a data,
retransmitted
modification has no service
None whose
resulting in failures QCI V100R003C00 Radio Engineering Design
impact on the is
to mapped
correctlyto a low
receive
The parameter
equipment. requirement
the retransmitted for the
modification has no
delay Ifisthis
data. not allowed V100R003C00 Radio Engineering Design
impact on the
The parameter to enter theisDRX
parameter set to
equipment.
modification has no state,
a largeit value,
is not the
None
power-saving
UE may keep for V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment. the UE. even when
waiting
modification has no retransmitted data
None V100R003C00 Radio Engineering Design
impact on the is lost. That is, the
The parameter
equipment. UE stays active,
modification has no
which
None is not power- V100R003C00 Radio Engineering Design
impact on the
The parameter saving.
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R003C00 Radio Engineering Design


- Hys > Thresh. The
triggering condition
of event A2 is as
The
follows: time-to-trigger
Ms + Hys <
helps
Thresh. reduceMs isthe the
number
measurement of inter- value
RAT
of the measurements
serving cell,
The parameter The prevent
and entering
Hys
conditionis theof event
modification has no The entering inter-
unnecessary Default/Recommen
hysteresis
A1 is as follows:for event V100R003C00 Radio
impact on the condition
RAT of eventMs ded
The parameter A1 or A2
-measurements.
Hys contained
> Thresh.
equipment. A1 is as follows:A Ms
The
modification has no in
The theentering
measurement Default/Recommen
-larger
Hys
larger >value
Thresh.
the value of of V100R003C00 Radio
impact on the configuration,
condition of and ded
The parameter
Thresh
Thresh
this is
parameter, theevent
results inthe
a
equipment. Thresh
A2
lower
The as is
isentering the
follows:
probability Ms
of
modification has no threshold
smaller
The the
entering for this
average Default/Recommen
threshold
+ Hys
triggering
condition for
<A Thresh.
event
of theA1
event V100R003C00 Radio
impact on the event.
number
condition larger
of inter-
of event ded
particular
Thresh event.
the a A
The parameter
equipment.
and
B1
value
RAT
A2 ofisThresh
istherefore
as
is as
follows:
follows:
Mn
Ms
larger
threshold
lower
+ Ofn value
probability
- Hys >ofthis
forlower Hys of
modification has no results in
measurements,
+ Hys < a
Thresh. and Default/Recommen
results
event.
stopping
Thresh. Ainlarger
a lower
inter-RAT V100R003C00 Radio
impact on the probability
the
Threshhigher of
the ded
The parameter
equipment. value ofisThresh
probability
measurements.
Mn is the
triggering
the
of A
event
probability
threshold
triggering for
event callA1
of this A1
modification has no results
smaller
measurement
and in
value
therefore a higherof
avalue Default/Recommen
drops.
event.
or A2. A larger V100R003C00 Radio
impact on the probability
Thresh
of leads
the probability
lower of to aof
neighboring ded
The parameter
equipment. value of Thresh
triggering event
higher
cell. Ofn
stopping is the A2
probability.
inter-RAT
modification has no results
and in a higher
therefore a Default/Recommen
frequency-specific
measurements. V100R003C00 Radio
impact on the probability
higher of A of
probability ded
offset
smaller ofvalue
the of
equipment. triggering
starting event A2
inter-RAT
neighboring
Thresh leads cell.
to
Not involved and
None therefore
measurements. aa V100R003C00 Radio Radio Planning
Thresh
higher is the A
probability.
higher
smaller probability
value of of
threshold for event
starting
Thresh inter-RAT
Not involved B1.
None Hysleadsis theto a V100R003C00 Radio Engineering Design
measurements.
lower probability. A
hysteresis for event
The parameter smaller
A larger value
value ofof
B1.
modification has no Thresh
this leads to a
parameter Default/Recommen
A larger value of V100R003C00 Radio
impact on the lower
results probability.
in a lower ded
The parameter Hys
A results
larger value in a
equipment. probability
lower probabilityof of of
modification has no this parameter Default/Recommen
handover
triggering to the B1 V100R003C00 Radio
impact on the results in aevent
CDMA2000 lower
1xRTT
ded
The parameter
equipment. and
A hence
larger valuecauses of
probability
cell, and a of
smaller
modification has no a lower
this probability
parameter Default/Recommen
handover
value leads to tothe V100R003C00 Radio
impact on the of handover.
results
CDMA2000 in a lower A alarge
1xRTT
ded
The parameter
equipment. higher probability.
value may
probability
cell, and a ofaffect
smaller
modification has no Default/Recommen
user
handoverexperience.
value leads to to the a A V100R003C00 Radio
impact on the ded
smaller
CDMA2000 value1xRTT
higher probability. of
equipment.
Hys leads
cell, and a to a
smaller
Not involved None
higherleads
value probabilityto a of V100R003C00 Radio Engineering Design
triggering
higher event B1.
probability.
Not involved A small
None value may V100R003C00 Radio Radio Planning
cause handover
The parameter decision errors and
modification has no ping-pong
None V100R003C00 Radio Engineering Design
impact on the handovers.
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R003C00 Radio Radio Planning
Not involved None V100R003C00 Radio Engineering Design
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment. The entering
modification has no condition of event
None V100R003C00 Radio Engineering Design
impact on the B1 is as follows: Mn
The parameter
equipment.
modification has no + Ofn - Hys >
A larger value of
None
Thresh. V100R003C00 Radio Engineering Design
impact on the this parameter
The parameter
equipment. Mn is the
results in a longer
modification has no measurement value
average
None SRI cycle V100R003C00 Radio Engineering Design
impact on the of the neighboring
The parameter for UEs in a cell
equipment. cell. Ofn is the
modification has no and a larger
frequency-specific
None V100R003C00 Radio Engineering Design
impact on the capacity of SRI
offset of the
The parameter
equipment. users in the cell, but
neighboring cell.
modification has no it may also lead to a
Thresh is the V100R003C00 Radio Engineering Design
impact on the longer average
threshold for this
equipment. delay of uplink
event. Hys is the
Not involved scheduling
None for UEs V100R003C00 Radio Radio Planning
hysteresis for this
in the cell. A smaller
event, which is
value of this
Not involved used
None to prevent V100R003C00 Radio Engineering Design
parameter results in
frequent triggering
The parameter a smaller
A larger capacity
value of
of event evaluation
modification has no of SRI
this users in a
parameter Default/Recommen
caused
The by radio
entering V100R003C00 Radio
impact on the cell.
results in a ded
The parameter signal
condition
A larger value oflower
fluctuation
eventor
equipment. probability
fading.
B1 is as of of Mn
follows:
modification has no this parameter Default/Recommen
handover
A
+ larger
Ofn - in to >the
value
Hys of V100R003C00 Radio
impact on the results a lower ded
The parameter CDMA2000
Hys
A results
larger
Thresh. value HRPD
in aof
equipment. probability of
modification has no cell,
lower
this
Mn and a smaller
probability
parameter
and Ofn are of
the Default/Recommen
handover
value leads to to
the a B1 V100R003C00 Radio
impact on the triggering
results
measurementin aevent
lower value ded
The parameter CDMA2000
higher HRPD
probability.
equipment. hence
probability causes
modification has no
and and a of
cell, frequency- smaller Default/Recommen
a lower
handover
specific
value probability
to to
offset
leads theof
a the V100R003C00 Radio
impact on the ded
of handover.
CDMA2000
neighboring
higher A large
HRPD
cell,
probability.
equipment.
valueand
cell, may
respectively. a affect
smaller
Thresh
Not involved None
userHys
value
and experience.
leadsareto the a A V100R003C00 Radio Radio Planning
smallerprobability.
higher
threshold value
and of
Not involved Hys
Noneleads to
hysteresis forathis V100R003C00 Radio Engineering Design
higher respectively.
event, probability of
The parameter A larger
A larger value
triggering event
value of
ofB1.
modification has no this parameter
A small value mayin Default/Recommen
hysteresis results V100R003C00 Radio
impact on the results
cause inprobability
a lower ded
The parameter
equipment.
a
A largerhandover
lower
probability value
ofeventof
modification has no decision
of
thistriggeringerrors
parameter and Default/Recommen
handover
ping-pong
B1 and to the a
therefore V100R003C00 Radio
impact on the results incell,
a lower ded
The parameter GERAN
handovers.
lower probability and a
equipment. A larger
probability
smaller of of of
value
value
modification has no handover.
this parameter A large Default/Recommen
handover
results in ato the
higher V100R003C00 Radio
impact on the value
results may
in a affect
lower ded
The parameter GERAN
probability. cell, and a
equipment. user experience.
probability of A
modification has no smaller value Default/Recommen
smaller
handover
results in value of
atohigher
the V100R003C00 Radio
impact on the ded
hysteresis
GERAN
probability. leads
cell, andtoa
equipment.
a highervalue
smaller probability
leads
Not involved None
of a
to triggering
higher event V100R002C00 Radio Radio Planning
B1. A small value
probability.
may cause
handover decision
errors and ping-
pong handovers.
condition of event
B1 is as follows: Mn
+ Ofn - Hys >
Thresh.
Mn is the
measurement value
of the neighboring
A
cell. larger
Ofn value
is the of
Not involved this
None parameter
frequency-specific V100R003C00 Radio Engineering Design
results
offset ofinvalue
a lower
the
The parameter A larger of
probability
neighboring ofcell.
modification has no this parameter Default/Recommen
handover
Thresh to the
is athe V100R003C00 Radio
impact on the results in lower ded
The parameter UTRAN
threshold cell,
for and a
equipment. probability
smaller value of event
leads
modification has no B1. Hys isto the Default/Recommen
handover
to a higher the V100R003C00 Radio
impact on the hysteresis for event ded
The parameter UTRAN larger cell,
probability.
A valueand of a
equipment. B1.
modification has no smaller
this value
parameter leads Default/Recommen
A
to larger
a higher value of V100R003C00 Radio
impact on the results in a lower ded
The parameter Hys results
probability.
A larger value in a
equipment. probability
lower of of of
probability
modification has no this parameter Default/Recommen
handover
triggering to the B1 V100R003C00 Radio
impact on the results
UTRAN aevent
incell, lower
and
ded
The parameter
equipment. and
A therefore
larger
probability valueof aof a
modification has no The
smaller
lower triggering
value
probability leads Default/Recommen
this
handover
condition
to
parameter
a higher the of
to event
of V100R003C00 Radio
impact on the handover.
results aAlower
incell, large ded
The parameter UTRAN
A1 is as
probability. follows: andMs a
equipment. value
probability may affect
of
modification has no smaller
-user value
Hysexperience.
> Thresh. A leads Default/Recommen
handover
to a higher to the V100R003C00 Radio
impact on the The triggering ded
smaller
UTRAN value
cell,
probability.of event of a
and
equipment. condition
Hys leads
smaller
The value to aleads
time-to-trigger
Not involved A2
None
higher is asprobability
follows: Ms V100R003C00 Radio Radio Planning
to a higher
helps
+ Hys reduce
< Thresh. the of
triggering
probability.
number
The of inter- B1.
event
Ms
A isentering
small thevalue may
Not involved frequency
None
condition
measurement of event value V100R003C00 Radio Engineering Design
cause
measurements
A1 is as handover
follows: andMs
The parameter of the
decision serving
errors and cell,
The
prevent
-HysHysis entering
>the
Thresh.
modification has no ping-pong Default/Recommen
condition
unnecessary is of event V100R003C00 Radio
impact on the Thresh
hysteresis
handovers. forinter-
the event ded
The parameter A1 is as follows:
frequency
threshold for the Ms
equipment. A1 orentering
The A2 contained
modification has no -event.
Hys >AThresh.
measurements. larger The Default/Recommen
in the measurement
condition of event V100R003C00 Radio
impact on the Thresh
larger
value isThresh
the
of the
value of ded
The parameter configuration,
A2 is as follows: and Ms
equipment. threshold
this
results
The parameter,
in
entering aforlower
thethe
modification has no Thresh
+ Hys < is the
Thresh. Default/Recommen
event.
smaller
probability
condition Athelarger
of average
of event V100R003C00 Radio
impact on the threshold
Thresh for
isThresh
the the ded
value
number
triggering
A2 of of inter-
event
is as follows: A1Ms
The parameter
equipment. particular
threshold event.
for the A
results
A larger
frequency
and
+ Hys inThresh.
hence
< a causes
value lower of
modification has no larger value
event. A smaller of Hys Default/Recommen
probability
this parameter
measurements, of V100R003C00 Radio
impact on the a lower
Thresh
results
value ofin athe
Threshlowerand
probability
is ded
The parameter triggering
results
the
of higher
stopping
threshold in aevent
lower
the
forinter-
the A1
equipment. probability
results
A larger invalue
aofof
lower of
modification has no and hence
probability
frequency
event. A smaller causes
call Default/Recommen
triggering
probability
this parameter event
of A1 V100R003C00 Radio
impact on the a lower
triggering
drops.
measurements.
value of probability
event
Thresh A4
A ded
The parameter or A2.
triggering
results event
in a causes
lower A2
equipment. of
and stopping
smaller
results
A hence
larger value
in a
value inter-
lowerof
of
modification has no and hence
probability
frequency
a lower causes
of
probability Default/Recommen
Thresh
probability
this
a leads
parameter
lower
triggering of to A4
probability
event a V100R003C00 Radio
impact on the measurements.
of handover. A
A large ded
The parameter higher
triggering
results
of
and startingprobability.
in
hence aevent
lower
inter-
causes A2
equipment. smaller
value mayvalue affectof
modification has no and hence
probability
frequency
a lower causes
of
probability Default/Recommen
Thresh
user
a lower leads
experience.
triggering probability
event to aA
A4 V100R003C00 Radio
impact on the measurements.
of handover. A
Aoflarge ded
The parameter higher
smaller
of
and startingprobability.
hencevalue inter-
causes this
equipment. A larger
larger
value
A larger may value
value
value of
of of
affect
modification has no parameter
frequency
a lower leads
probability to Default/Recommen
this
Thresh
user
this parameter
leads
experience.
parameter to aA V100R003C00 Radio
impact on the a higher
measurements.
of handover. probability Athis
Aoflarge ded
The parameter results
higher
smaller
results in a
a lower
probability.
value
in lower
equipment. of triggering
larger
value
A larger value
may value event
of
affect of
modification has no probability
parameter
probability of
leads
of to Default/Recommen
A4.
Thresh
user
this A small
leads
experience.
parameter value
to A4
aA V100R003C00 Radio
impact on the handover
a higher
triggering to an
probability
event ded
may
higher
smaller
results cause
probability.
value
in a causes
lowerofcell,
this
The parameter
equipment. inter-frequency
of
and triggering
hence event
handover
parameter decision
leads
modification has no probability
a
A4.
a smaller
errors A small
lower ofvalueto
average
probability
and ping- V100R003C00 Radio
Default/Recommen
impact on the a higher
triggering
number
may
of cause
handover. probability
of event A4
A large ded
The parameter pong
of
and handovers.
triggering
hence event
causes
equipment. handovers,
handover
value affecta
maydecision and
modification has no A4.
a A
lower
higher small valueA
probability
call drop Default/Recommen
errors and
user experience. ping- V100R003C00 Radio
impact on the may
of cause
handover. ded
The parameter rate.
pong
smaller valueAoflarge
Ahandovers.
smaller this
equipment. handover
value may
of this decision
affect to
modification has no parameter leads Default/Recommen
errors
user
parameter
a higher and
experience.ping- to
leads
probability A V100R003C00 Radio
impact on the ded
The parameter pong
smaller
the handovers.
value
opposite
of triggering event of this
effect.
equipment.
modification has no parameter
A4. A smallleads valueto Default/Recommen
None
a higher probability V100R003C00 Radio
impact on the may cause ded
The parameter
equipment. of triggering event
handover decision
modification has no A4. A small value Default/Recommen
errors
None and ping- V100R003C00 Radio
impact on the may ded
pongcause handovers.
equipment. handover decision
errors and ping-
pong handovers.
A larger value of
The entering
this parameter
condition
results in a oflower
event
A1 is as
probability follows:
of Ms
TheHysentering
-triggering
> Thresh.
condition event A3
Thresh
and is of
thereforetheevent
a
The parameter A2 is as follows:
threshold for the Ms
lower
+ Hys probability
< Thresh. of
modification has no event. A larger Default/Recommen
handover.
Thresh A
is the smaller V100R003C00 Radio
impact on the value of ded
The parameter value
thresholdof Thresh
this the
equipment. results
parameter in afor lowerto
leads
modification has no event. A smaller Default/Recommen
probability
a higher of
probability V100R003C00 Radio
impact on the value of Thresh ded
The parameter triggering
of triggering eventeventA1
equipment. results
A larger in a causes
value lower
of
modification has no and
A3 hence
and therefore a Default/Recommen
probability
this
a parameter
lower of
probability V100R003C00 Radio
impact on the higher probability of ded
triggering
results
of in aevent
stopping inter-A2
lower
equipment. handover.
A positive value of
and hence of
probability
frequency causes
Not involved None
this
a lowerparameter
triggering probability
event A A3 V100R003C00 Radio Radio Planning
measurements.
results in ainter-
of
and starting
smallerhencevalue causes
of
relatively
This
frequency
a lower low
parameter
probability
Not involved Thresh
None
probability leads to a
of Athe V100R003C00 Radio Engineering Design
helps
of reduce
measurements.
handover.
higher probability. A
large
The parameter triggering event
average
larger may
value number
value of A3
affect of
modification has no and therefore
handovers and a the Default/Recommen
Thresh
user leads to aA
experience. V100R003C00 Radio
impact on the relatively
number oflow of this ded
The parameter higher probability.
smaller value
equipment. probability
modification has no parameter of
unexpected leads to Default/Recommen
handover.
handovers, Aand
a higher probability V100R003C00 Radio
impact on the ded
The parameter negative
hence value
prevents
of triggering of
event
equipment.
modification has no this parameter
unnecessary
A3. A small value Default/Recommen
leads to a relatively V100R003C00 Radio
impact on the handovers.
may cause A larger ded
equipment. high
value
handoverprobability
of thisdecision of
Not involved triggering
parameter
None and results
errors event
ping- A3in V100R002C00 Radio Radio Planning
and
a therefore
smaller
pong handovers. averagea
The parameter
relativelyofhigh
number
modification has no
probability
None
handovers, ofbut it V100R002C00 Radio Radio Planning
impact on the
The BS should be handover.
also leads to a
equipment.
reset to validate the higher risk of call
None V100R002C00 Radio Radio Planning
parameter drops.
The BS should be
modification.
reset to validate the
None V100R003C00 Radio Radio Planning
parameter
The BS should be
modification.
reset to validate the
None V100R003C00 Radio Radio Planning
parameter
modification.
Not involved None V100R003C00 Radio Radio Planning
The cell should be
reset to validate the
None V100R003C00 Radio Radio Planning
parameter
The cell should be
modification.
reset to validate the
None V100R003C00 Radio Radio Planning
parameter
modification.
Not involved None V100R003C00 Radio Radio Planning
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The BS should be
equipment.
reset to validate the
None V100R003C00 Radio Radio Planning
parameter
modification.
Not involved None V100R003C00 Radio Radio Planning
The parameter
modification has no
None V100R003C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning
The link should be
reestablished after
None V100R001C00 Radio Radio Planning
the parameter
The link should be
modification.
reestablished after
None V100R002C00 Radio Radio Planning
the parameter
The link should be
modification.
reestablished after
None V100R003C00 Radio Radio Planning
the parameter
The parameter
modification.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Not involved

Not involved None V100R001C01 Radio Not involved

Not involved None V100R003C00 Radio Not involved

Not involved None V100R001C01 Radio Not involved

Not involved None V100R001C01 Radio Not involved

Not involved None V100R003C00 Radio Not involved

Not involved None V100R001C01 Radio Not involved

Not involved None V100R001C01 Radio Not involved

Not involved None V100R003C00 Radio Not involved

Not involved None V100R001C00 Radio Radio Planning


The link should be
reestablished after
None V100R001C00 Radio Radio Planning
the parameter
The link should be
modification.
reestablished after
None V100R002C00 Radio Radio Planning
the parameter
The link should be
modification.
reestablished after This
Noneparameter has V100R003C00 Radio Radio Planning
the parameter an impact on
The parameter
modification. automatic removal
modification has no
of the X2 interface V100R001C01 Radio Radio Planning
impact on the
in a situation where
equipment.
the peer eNodeB is
Not involved None
removed. V100R003C00 Radio Not involved
Not involved None V100R003C00 Radio Not involved
If this parameter is
Not involved set
None to ON, the UE V100R001C00 Radio Not involved
may enter the DRX
The parameter
state, saving UE
modification has no
power. If this has
This parameter V100R001C01 Radio Engineering Design
impact on the
The parameter parameter
little impactison setradio
to
equipment.
modification has noOFF, the UE
network
This
consumes parameter has
relatively V100R001C01 Radio Engineering Design
impact on the performance, but it
The parameter
equipment. little
much impact
power.
has an impact on on the
modification has noradio
UEs. network Default/Recommen
This parameter has V100R002C00 Radio
impact on the performance, but it ded
The parameter
equipment. little
has an impact
impact on onthe
modification has noradio
UEs. network Default/Recommen
This parameter has V100R002C00 Radio
impact on the performance, but it ded
The parameter
equipment. little impact
has an impact on on the
modification has noradio
UEs. network Default/Recommen
This parameter has V100R002C00 Radio
impact on the performance, but it ded
The parameter
equipment. little
has an impact
impact on onthe
modification has noradio
UEs. network Default/Recommen
This parameter has V100R002C00 Radio
impact on the performance, but it ded
The parameter
equipment. little impact
has an impact on on the
modification has noradio
UEs. network Default/Recommen
This parameter has V100R002C00 Radio
impact on the performance,
IMS signaling but
and it ded
The parameter
equipment. little
has an impact
low-delay impact on on
services the
modification has noradio network
UEs.prioritized
are Default/Recommen
V100R002C00 Radio
impact on the performance,
during scheduling but it ded
equipment. has an impact
but consume many on
Not involved UEs.
None
resources to ensure V100R002C00 Radio Engineering Design
If this parameter is
The parameter their QoS.
set to a large value,
modification has noTherefore,
This parameter it is has
the minimum V100R002C00 Radio Engineering Design
impact on the recommended
an
If impact
this onbitthe
parameter that
is
The parameter guaranteed rates
equipment. this to
set parameter
throughput a large and not
the
value,
modification has no(Min_GBR)
This parameter of high-
has
be set
QoS
the to
differentiation
minimum V100R001C00 Radio Engineering Design
impact on the priority
an impact non-GBR
on the
IMSSignalling
service. Its or
The parameter
equipment.
guaranteed
services
throughput canvalue
bit
andberates
the
is
modification has noLowDelay
subject
(Min_GBR) to for
the of TCP
high-
guaranteed,
QoS differentiation V100R001C00 Radio Engineering Design
impact on the services
operator's
priority and non-
policy.
non-GBR
whereas
service. Min_GBR
The parameter
equipment. real-timeIts
services can value
streaming
be is
of
This low-priority
subject to
parameterthe non-
modification has noservices.
guaranteed,
GBR
operator's
affects services
the policy.may V100R002C00 Radio Engineering Design
impact on the whereas Min_GBR
The parameter fail to be
preallocation
equipment. of low-priority non-
modification has noguaranteed
opportunity when
of its is
GBR
If this
resources services
parameterare may V100R002C00 Radio Engineering Design
impact on the corresponding type
The parameter fail
set to be
insufficient.
equipment. of service and
modification has noguaranteed
PBR_0_KBps,
If this parameter when is
therefore
resources
there is a affects thatthe
are value,
risk V100R002C00 Radio Engineering Design
impact on the set to a small
The parameter service
insufficient.
the delay. The
corresponding
equipment. there may
modification has nodelay
If has
this parameter
services abenever
an
is
impact
None
negative onarethe
correlation V100R003C00 Radio Engineering Design
impact on the set to a small
scheduled. value,
If this
The parameter response
with the time of
equipment. there
parameter mayservices.
be an to
is set
modification has nonon-GBR
preallocation
impact on the and
PBR_INFINITY V100R003C00 Radio Engineering Design
impact on the weight.
Services with
The parameter response
the time of
corresponding
equipment. relatively high
modification has nonon-GBR
traffic volume services.
is
priorities
high, there areis a risk V100R003C00 Radio Engineering Design
impact on the
The parameter scheduled
that the services
equipment.
modification has nopreferentially.
with
NoneQCIs indicating V100R003C00 Radio Engineering Design
impact on the lower priorities than
The parameter
equipment. this QCI are never
modification has no
scheduled.
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R003C00 Radio Engineering Design
The parameter
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Radio
impact on the A larger value of ded
The parameter
equipment.
modification has no this parameter Default/Recommen
None to a higher
leads V100R003C00 Radio
impact on the A larger value of ded
The parameter
equipment. interference
modification has no this parameter
resistance Default/Recommen
None
leads to a higher V100R003C00 Radio
impact on the capability, but a ded
The parameter
equipment. interference
larger number of
modification has no resistance
retransmissions Default/Recommen
None V100R003C00 Radio
impact on the capability,
results in abut longera ded
The parameter
equipment. A large
larger value
number ofofthis
modification has no delay and lower Default/Recommen
parameter
retransmissions
None
throughput. Set this may V100R003C00 Radio
impact on the result
results ininaalong longer ded
equipment. parameter to a
delay
small valueof services
and lower
for
Not involved Nonea failureSet
and V100R003C00 Radio Engineering Design
services with to
throughput. a highthis
The parameter meet
parameter the QCI
requirement for the to a
modification has no requirement.
small
delay value
and to aA large
for
To prevent the send V100R003C00 Radio Engineering Design
impact on the small
services
value value
for with of
services athis
high
The parameter
equipment. window
To prevent may
parameter size from
buffer
requirement
with a low for lead
the
modification has no changing
overflow
to a severe to case
caused 0, theby of
delay
None
To and
prevent the
requirement to a large
forsendthe V100R003C00 Radio Engineering Design
impact on the transmitter
an
PDCP excessively
data initiateslong
The parameter value
window
delay.
To preventfor
RRC services
sizebuffer from
equipment. status
queue
discarding reporting
waiting and for
modification has no with
changinga low
connection
overflow to
caused 0, theby
based
therefore on
acknowledgments, the
low V100R003C00 Radio Engineering Design
impact on the requirement
transmitter
reestablishment
an forlong
initiates the
The parameter theexcessively
number
throughput.
delay. RRC
of PDUs.
transmitter A
equipment. status
has
queue
small a reporting
great
waiting
value impactfor
(smaller
modification has no initiates
connection status
based
on oron
acknowledged
acknowledgments,
than equalthe to V100R003C00 Radio Engineering Design
impact on the reporting
reestablishment based on
number
mode
the (AM)of
transmitter
PollPdu_p16) PDUs. ofhas A
The parameter
equipment. the
This
has data volume
parameter
a value
great impact of
small
services,
initiates
this such
status
parameter (smaller
as
modification has no transmitted
an
on impact
acknowledged on PDUs.
statusA
than
TCP or inequal to on V100R003C00 Radio Engineering Design
impact on the smallservices
reporting
results
reporting
mode value
(AM)
based
a high
in of that
this
The parameter PollPdu_p16)
are
the
This packet-loss-
data
frequency volume
parameter of ofhasof
equipment. parameter
acknowledged
services, results
such asisin
modification has no this parameter
sensitive
transmitted and delay-
PDUs.
If
an
a
TCP
this
impact
sending parameteron
A polling
lowservices
mode. frequency
low that status of A V100R003C00 Radio Engineering Design
impact on the results
insensitive,
small
set to
reporting
PDUs, a in
value a
small
in
a polling
short high
of this
value,
The parameter sending
frequency
are packet-loss- of status
frequency
because of
packets
equipment.
modification has no
parameter
too many
acknowledged
round-trip
PDUs.
reporting
sensitive
If this A largeresults
polling
time
leads
and
parameter toisin
for
value
delay-
in
a
sending
the
a low
PDUs
mode.
RLC buffer A polling
frequency
may low
packets, are
be of
sent.
and V100R003C00 Radio Engineering Design
impact on the leads
low to
insensitive,
set to high buffer
frequency
aasmall of a
value,
PDUs,
discarded
sending
In
highaddition,
frequencyspeed short
upon
polling
of the
at statusthe
which
The parameter
equipment. usage
status
because
too many and
report a
packets
polling slow in
round-trip
reestablishment.
PDUs.
number
reporting A time
large
of ARQ
leads for
value
modification has no the
speed send
scheduling
the
PDUs buffer at window
may which
arebutsent.
be athea
to
RLC
leads
low
moves. packets,
Therefore, toIfhigh
retransmissions
frequency a large
the and
ofthata
buffer
send V100R003C00 Radio Engineering Design
impact on the send
high
discarded
In window
probability
addition, upon
the the
The parameter high
value
usage
may
status
window speed
of
reach this
and
report
size aatis
its which
slownot
equipment. moves.
the
number
A sendvalue
reestablishment.
small ofwindow
ARQ of this
modification has no the
speed send
parameter
maximum
scheduling
0, however, window
at to isbut
which
due athe
to
changes
Therefore,
retransmissions
parameter a 0alarge
may
small
at the V100R003C00 Radio Engineering Design
impact on the moves.
recommended,
send
consecutive
high If
window
valueprobability the
of thisthereby send
PDU that
The parameter transmitter,
value
may
result of
reach this
in size
uselessitsis not
equipment. window
reducing
moves.
retransmissions,
the send
parameter the
window
may lead
modification has no reducing
A small
parameter
maximum the
value is0aRRCof this
HARQ
0,
to however,
probability
and antherefore
changes todue
excessive
transmission of tothe
small
the
at V100R003C00 Radio Engineering Design
impact on the parameter
recommended,
consecutive
retransmissions
value
connection
RRC of of
this
connection
transmitter,
may PDUisA
rate.
thereby
The parameter number
high
result frequency
in status
useless of
equipment. reducing
retransmissions,
from
parameterthewhile
reestablishment.
reestablished.
reducing the
transmitter
the may Iflead
this
modification has no reports
status
HARQ reporting not
probability
and
to therefore
anrepeated
parameter excessive
transmission of
is RRC
thetoA
status
set
rate. V100R003C00 Radio Engineering Design
impact on the increasing
leads to
retransmissionsa the
high
The parameter connection
RRC
reports
number
a large
high connection
from
of status
value,
frequency theofis
equipment. transmission
probability
from the of speed.
transmittertimely
modification has no reestablishment.
reestablished.
receiver,
reports
status thereby
while not
reports
reporting If this
may
A large
acknowledgmentvalue of this
impact on the
and
not
leads
The be
repeated
parameter
wasting
increasing to
PDCP sent
a is
resources.
the
highin
status
set
time. toto V100R003C00 Radio Engineering Design
parameter
data
reports in the
from results
sendthe in
The parameter
equipment. a
A large value,
transmission
probability
sequence value of
number ofsend
speed.
timelythis
a low
window
receiver, speedand
thereby of
modification has no status
parameter
A large reports
acknowledgment
size must value may may
of lead
thisto
impact on the
window
therefore
wasting
not
to a belong sent abehigh
movement.
resources.
delay
set
inlarge
time.
to
for in
V100R003C00 Radio Engineering Design
parameter
data
a in the
sufficiently results
send
The parameter
equipment. probability
A
thelarge
receivervalue of torate
of this
a low
window
value speed
to and
prevent of send
modification has no guarantee.
parameter
determine may
an out-lead
window
therefore
Hyper movement.
Frame a high V100R003C00 Radio Engineering Design
impact on the However,
to a
of-orderlong a
delay
packet high for
The parameter
equipment. probability
Number
frequency
the receiver (HFN)ofto
of rate
status
modification has no transmission
guarantee.
mismatch caused failure
reporting
determine
and therefore results
an out-a in V100R003C00 Radio Engineering Design
impact on the However,
by
a severe
high
of-order apacket
probability
packet high of
equipment. long
frequency
loss. delay
However, forstatus
of a
status
transmission
sending report
status failure
reporting
longer
scheduling
and PDCP
therefore results
anda in
reports,
a high
sequence thereby
probability
number of
repeated
long
delaying delay for
services
status
results report
in
transmissions,
sending more
statusthe
and
PDCP reducing
scheduling header and
thereby
reports,
throughput. wasting
thereby
repeated
overhead
resources.
delaying and
services lower
transmissions,
payload throughput.
and reducing the
The value of this
parameter must be
sufficiently large to
A small
prevent
The value
sequencesequence of this
parameter
number
number size may
ambiguity
The parameter result
caused
specified inby useless
byHARQ this
A small value
HARQ of this
modification has noretransmissions.
parameter must be
parameter
retransmissions may V100R003C00 Radio Engineering Design
impact on the Note that
large enough an to
The parameter result
from in useless
the transmitter
equipment. excessively
prevent sequence large
modification has noHARQ
and a large number
value
number of this
ambiguity V100R003C00 Radio Engineering Design
impact on the retransmissions
of lost packets. A
The parameter parameter,
caused by HARQ
equipment. from
large the
value transmitter
modification has nohowever,
retransmissions. willoflead this to
and
If thisa RLC
parameter largemay
parameter number is
lead V100R003C00 Radio Engineering Design
impact on the great
However, a large
of
set
to lost
a tolong packets.
FALSE, delay theA
for
The parameter
equipment. overhead.
size results in thisa
large
target
the value
eNodeB
receiver of to will
modification has noheavy RLC header
parameter
transmit
determine allanmay
data out- lead V100R003C00 Radio Engineering Design
impact on the load.
The parameter to a longpacket
forwarded
of-order delay
by the for
equipment.
modification has nothe
sourcereceiver
transmission eNodeB. tofailure,
determine an out-is V100R003C00 Radio Engineering Design
impact on the Part
thisofparameter
thereby
If the data
delaying
equipment. of-order
may
services
set have
to a largepacket
been
and value,
Not involved transmission
This
reducing
None
the parameter
transmitted
minimum thetofailure, has
UEs, V100R003C00 Radio Engineering Design
thereby
an
If impact
this
throughput. delaying
parameteron
wasting
guaranteed bit rates the is
The parameter
services
throughput
set to a large
resources
(Min_GBR) and and
on of the
value,
the
high- air
modification has noThis parameter
reducing
QoS
the the has
differentiation
minimum
interface.
priority non-GBR V100R003C00 Radio Engineering Design
impact on the an impact onbitthe
The parameter throughput.
service.
guaranteed
services Its
canvalue berates is
equipment. throughput and the
modification has nosubject
(Min_GBR)
guaranteed, to the of high-
QoS differentiation
operator's
priority non-GBRpolicy. V100R003C00 Radio Engineering Design
impact on the whereas Min_GBR
The parameter service.
services Its
canvalue be is
equipment. of low-priority non-
modification has nosubject
This to
parameter
guaranteed, the
GBR
operator's
affects services
the policy. may V100R003C00 Radio Engineering Design
impact on the whereas Min_GBR
The parameter fail to be
preallocation
equipment. of low-priority non-
modification has noguaranteed
opportunity when
of its
GBR
This
resources services
parameter are may V100R003C00 Radio Engineering Design
impact on the corresponding
The parameter fail to
affects be
insufficient. the pre-type
equipment. of service and
modification has noguaranteed
allocation
If this whenis
If this parameter
therefore
resources
probability affects
parameter are the
is V100R003C00 Radio Engineering Design
impact on the set to
service
set to small its
a delay. of value,
The
The parameter
equipment. insufficient.
corresponding type
there
delay may
PBR_0_KBps,has and abe an is
modification has noIf
of this
serviceparameter
impact
None
negative
there oncorrelation
the that V100R003C00 Radio Engineering Design
impact on the set to is
therefore
response aa risk
small
timevalue,
affects of the
The parameter
equipment. with
the the
corresponding
there
delay
non-GBR may
of other be an
services. types
modification has nopreallocation
services
impact
of service. onare the
The never V100R003C00 Radio Engineering Design
impact on the weight.
scheduled. If this
The parameter response
bigger thetime pre- of
equipment. parameter is set to
modification has nonon-GBR
allocation
This parameter services.
weightand is,
PBR_INFINITY
the
other smaller
associated the and V100R003C00 Radio Engineering Design
impact on the Services with
The parameter the
delay corresponding
factors is.have
The
equipment. relatively
traffic volume highan is
modification has nosmaller
impact
The the
on
setting thepre-
of CQI this
priorities
high, there are is a risk V100R003C00 Radio Engineering Design
impact on the allocation
reporting
parameter weight
mode andis,
The parameter scheduled
that the services
equipment. the bigger
reporting
determines the
the delay
modification has nopreferentially.
with QCIs indicating Default/Recommen
The
is. setting
parameters,
transmission ofand this
modes V100R003C00 Radio
impact on the lower
parameter priorities than ded
The parameter therefore
that are applicableaffect the
equipment. this QCI
determines are thenever
modification has nofeedback
to the UEs served overhead
scheduled.
transmission
in the uplink and modes V100R001C01 Radio Engineering Design
impact on the by a multi-antenna
The parameter
equipment. that are applicable
throughput
eNodeB andorhence
modification has noto the UEs
coverage
affects inserved
performancethe V100R003C00 Radio Engineering Design
impact on the by a
downlink.multi-antenna
such as the
The parameter
equipment. eNodeB andand hence
modification has nothroughput Default/Recommen
affects
None performance
coverage. V100R001C00 Radio
impact on the such as the ded
The parameter
equipment.
modification has nothroughput and Default/Recommen
None
coverage. V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
equipment.
The parameter
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None
A decrease in the V100R001C00 Radio
impact on the ded
The parameter value of this
equipment.
modification has no parameter indicates Default/Recommen
None
a V100R001C00 Radio
impact on the A decrease
smaller value in the of ded
The parameter
equipment. number
When of
this parameter is
the value
modification has no candidate Default/Recommen
None in acells
increased,
results the
larger for V100R001C00 Radio
impact on the each
number handover.
of reports In ded
The parameter number of reports
equipment. this case,
increases the
and the
modification has no and greater Default/Recommen
success
handoverrate
consumption success of
of the V100R001C00 Radio
impact on the ded
The parameter handover
rate rises
radio interface triggered
to a
equipment.
modification has no by eachextent.
certain
resources. A larger An Default/Recommen
A smaller value
measurement of V100R001C00 Radio
impact on the excessively
value of this large ded
The parameter this parameter
report is decreased,
equipment. number of reports,
parameter
modification has no results
but the in aleads
requiredlargerto Default/Recommen
however,
a longer results
delay of in V100R001C00 Radio
impact on the number
amount
A smallerof ofvalue
reports,
radio of ded
The parameter excessive
handover signaling
retries
equipment. greater
interface
this parameterresource
modification has no and
and hence
hence a lower causes Default/Recommen
consumption
is
Nonereduced.
results inofasuccess of
larger V100R001C00 Radio
impact on the a waste
handover radio ded
radio
number interface
ofresources.
reports
The parameter
equipment. interface
rate. In the early
resources
and greater and a
modification has no stage of LTE Default/Recommen
higher
consumption handover of of V100R001C00 Radio
impact on the deployment,
A smallerrate. value this ded
The parameter success
radio interface A
equipment. parameter
this parameter should
modification has no larger
resources. value A of this
larger Default/Recommen
be
None set to
results
parameter in aaleads
small
larger to V100R001C00 Radio
impact on the value of ofthis ded
The parameter value
number
a longer to ensure
reports
delay of to
equipment. parameter leads
modification has no timely
and
handover handovers.
greater retries Default/Recommen
a longer delay
consumption ofof V100R001C00 Radio
impact on the and thus a lower ded
The parameter handover
radio interfaceretries
equipment. handover
modification has no and hencesuccess
resources. Aa larger
lower Default/Recommen
rate.
None
A decrease
handover in the
success V100R001C00 Radio
impact on the value of this ded
The parameter value
rate. Inofthethisearly
equipment. parameter leads to
modification has no parameter
stage of LTE indicates
a
a longer delay
decrease inthis of
the V100R001C00 Radio Engineering Design
impact on the deployment,
The parameter handover
number of retries
equipment. When
parameter the value
should is
modification has no and hencecells
candidate a lower for Default/Recommen
increased,
be
None set to a the
small V100R001C00 Radio
impact on the handover
each handover.success In ded
The parameter number
value totheof reports
ensure
equipment. rate.
this In
case, theearly
modification has no increases
timely and the
handovers. Default/Recommen
stage
success of LTE of the
impact on the handoverrate success V100R001C00 Radio
ded
deployment,
handover this
triggered
The parameter
equipment. rate rises to a
parameter
by eachextent. An should
modification has no certain Default/Recommen
be set to a small
measurement V100R001C00 Radio
impact on the excessively large ded
The parameter value
report to ensure
is of
decreased,
equipment. number reports,
modification has no timely
but the handovers.
required Default/Recommen
however,
None results in V100R001C00 Radio
impact on the amount of signaling
excessive radio ded
equipment. interface
and hence resource
causes
is reduced.
a waste of radio
interface resources.
A smaller value of
this parameter
If this parameter
results in a largeris
set to BOTH,
number of reports, the
The parameter eNodeB
greater evaluates
modification has no both the measured
consumption of of Default/Recommen
None
A smaller
RSRP andvalue RSRQ V100R001C00 Radio
impact on the radio interface ded
The parameter this
values parameter
for each
equipment. resources
modification has no results in aand
inter-frequency larger a
Default/Recommen
higher
If this
number handover
parameter
of reports, is V100R001C00 Radio
impact on the neighboring ded
The parameter success
set
greaterto BOTH, rate.cell.A
the
equipment. The cells with
modification has no larger
eNodeB
consumptionvalue sends ofofboth
this
UEs Default/Recommen
the measured
parameter
two measurement leads to V100R001C00 Radio
impact on the radio interface ded
The parameter RSRP
a longer and
configurations RSRQ
delay of
for
equipment. resources and athe
modification has no values
handover
events meeting
A1 retries
and A2: Default/Recommen
higher handover
corresponding V100R001C00 Radio
impact on the and
one thusbased a lower
on A ded
The parameter success
entering rate.
conditions
equipment. handover
RSRP, and success
the
modification has no larger
are value
reported of
and this Default/Recommen
rate.
other
parameter based on
leads to V100R001C00 Radio
impact on the arranged based on ded
The parameter RSRQ.
a longer Ifdelay
either of
equipment. RSRP values to
modification has no measured
handover value
retries Default/Recommen
generate
None
meets a list
theacondition of V100R001C00 Radio
impact on the and thus lower ded
The parameter candidate
for event cells.
A2, event
equipment. If
handover success
modification has no A2 is reported and
AcBarringForMoDat Default/Recommen
rate.
None V100R001C00 Radio
impact on the the inter-frequency
aCfgInd or ded
equipment. A larger value of
measurement
AcBarringForMoSig is
Not involved this
CfgInd parameter
triggered.
None in SIB2 is V100R002C00 Radio Radio Planning
results
set in a lower
to CFG, the UE
The parameter A larger value
probability
draws a random of of
modification has no this parameter
handover
number to the V100R002C00 Radio Radio Planning
impact on the results
UTRAN in'rand'
a lower
cell,
that
and a
The parameter A larger value
equipment. is uniformly
probability
smaller value of of
modification has no this parameter
distributed
handover
results in tointhe
a
the V100R002C00 Radio Radio Planning
impact on the results[0,1).
range
GERAN a higher
incell, lower
Ifand
randa
The parameter probability.
A
equipment.
modification has no is larger
probability
less than
smaller
value
value of of
this
handoverparameter
AcBarringFactorForto V100R002C00 Radio Radio Planning
impact on the results
results in
in a a higher
lower
The parameter CDMA2000,
Call or
probability.
A larger value andof a
equipment. probability of
modification has no smaller
this value
AcBarringFactorFor
parameter
handover
results thein to
a V100R002C00 Radio Radio Planning
impact on the Sig,
If
results
UTRAN, inUE a higher
and lower
athe
The parameter probability.
A larger value
equipment. considers that
AcBarringForMoDat
probability
smaller value of of
modification has no this
RRC
aCfgInd parameter
connection
intoSIB2 is
handover
results in a higher V100R001C00 Radio Radio Planning
impact on the results
can be in
set a uplower
The parameter set
UTRAN, to CFG,
probability.
A larger and
value afor
the
of
UE
equipment. probability
the
draws mobile-
a of
random
modification has no smaller
this value
parameter
handover
originated
number
results in to
acall
'rand' the or
that V100R002C00 Radio Radio Planning
impact on the results
GERAN
signaling
is uniformly a higher
incell, lower
and a
The parameter
equipment. probability.
probability
smaller value
respectively.
distributed of
in Ifthe the
modification has no Default/Recommen
handover
resultsof
value
range to
in a higher
[0,1). If rand V100R002C00 Radio
impact on the ded
CDMA2000,
probability.
AcBarringFactorFor
is less than the and a
equipment.
smaller
Call
value value
orof this
Not involved None
results in a the higher V100R001C00 Radio Radio Planning
AcBarringFactorFor
parameter, UE
The parameter probability.
Sig is set to
considers a large
access to
modification has no
value,
the celltheas allowed. V100R001C01 Radio Engineering Design
impact on the
The parameter probability
That is, an of RRC
equipment.
modification has no allowing access
connection can be to
None
the cellfor
set up is high.
the In V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment. this case, the cell
mobile-originated
modification has no load
NoneIfmay
call. thisincrease. V100R001C01 Radio Engineering Design
impact on the If the valueisofset to
parameter
The parameter
equipment. AcBarringFactorFor
a large value, the
modification has no Default/Recommen
Call or
probability of V100R001C00 Radio
impact on the ded
The parameter AcBarringFactorFor
allowing access to
equipment.
modification has no Sig cell
the is setis to a small
high, Default/Recommen
None
value, may
which the lead to a V100R001C00 Radio
impact on the ded
The parameter
equipment. probability
high of If this
cell load.
modification has no allowing
parameter access
is set toto Default/Recommen
None V100R001C00 Radio
impact on the the
a cell value,
small is low. the
In ded
The parameter
equipment. this case, UEs
probability of may
modification has no fail to access theto Default/Recommen
allowing
None access V100R001C00 Radio
impact on the cell cell
evenis when ded
the low, inthe
equipment. cell load is relatively
which situation UEs
light. fail
may If to access
AcBarringFactorFor
the cell even when
Callcell
the or load is
AcBarringFactorFor
relatively light. If
Sig
this is set to P00,
parameter is an
RRC
set toconnection
P00, an RRC is
CfgInd in SIB2 is
set to CFG, the UE
draws a random
number 'rand' that
is uniformly
distributed in the
The parameter range [0,1). If rand
modification has no is less than the Default/Recommen
None V100R001C00 Radio
impact on the value of this ded
The parameter
equipment. parameter, the UE
modification has no Default/Recommen
None
considers access to V100R001C00 Radio
impact on the ded
The parameter the cell as allowed.
equipment.
modification has no That is, an RRC Default/Recommen
None
connection can be V100R001C00 Radio
impact on the ded
The parameter
equipment. set up for the
modification has no signaling. If this
None V100R001C01 Radio Engineering Design
impact on the parameter is set to
The parameter
equipment. a large value, the
modification has no Default/Recommen
probability of V100R001C00 Radio
impact on the ded
The parameter allowing access to
equipment.
modification has no the cell is high, Default/Recommen
None
which may lead to a V100R001C00 Radio
impact on the ded
The parameter
equipment. high cell load. If this
modification has no parameter is set to Default/Recommen
None V100R001C00 Radio
impact on the a small value, the ded
The parameter
equipment. probability of
modification has no Default/Recommen
allowing
None access to V100R001C00 Radio
impact on the ded
The parameter the cell is low, in
equipment.
modification has no which situation UEs Default/Recommen
None
may fail to access V100R001C00 Radio
impact on the ded
The parameter
equipment. the cell even when
modification has no the cell load is Default/Recommen
None V100R001C00 Radio
impact on the relatively light. If ded
The parameter
equipment. this parameter is
modification has no set to P00, an RRC Default/Recommen
None V100R001C00 Radio
impact on the connection is ded
equipment. prohibited from
Not involved None set up for the
being V100R001C00 Radio Radio Planning
The parameter signaling.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
equipment.
Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification takes
Default/Recommen
effect after the cell None V100R001C00 Radio
The parameter ded
is automatically
modification
reset. takes
Default/Recommen
effect after the cell None V100R001C00 Radio
The parameter ded
is automatically
modification
reset. takes
Default/Recommen
effect after the cell None V100R001C00 Radio
ded
is automatically
reset.
Not involved None V100R001C00 Radio Radio Planning
unchanged, a larger
value of this
parameter indicates
a lower probability
of
The reselection
greater the to
intra-frequency
parameter, the or
same-priority
more difficult for the
The parameter
neighboring
UE to enter the cells,
modification has no Default/Recommen
and the service
high-mobility or V100R001C00 Radio
impact on the ded
The parameter drop rate increases.
medium-mobility
equipment.
modification has no A smaller
state, value
thevalue
smaller of
The
None
A greater
larger theof V100R001C00 Radio Engineering Design
impact on the this
the parameter
impact of
The parameter parameter,
this parameter the
equipment. indicates
mobility a higher
state on
modification has no slower for
indicates a thelowerUEthe to Default/Recommen
probability
reselection. of The V100R001C00 Radio
impact on the decide
probability
A the
larger value mobility.
of a UE
of ded
reselection
smaller the to intra-
The parameter
equipment. Thus,
entering
this the the
parameter
frequency
parameter, or thesame-
modification has no adjustment
medium
indicates mobilityof the
a lower Default/Recommen
priority
easier neighboring
for the UE to V100R001C00 Radio
impact on the reselection
state.
probabilityIn this of case,
a UE ded
The parameter cells,
enter but
the a high-larger
equipment. parameter
the reselection-
entering the is slower
high
modification has no number
mobility of
or pingpong
medium- Default/Recommen
,mobility
and the
related impact
parameters
state. In of V100R001C00 Radio
impact on the cell reselection.
mobility state, ded
The parameter the
A
are
this mobility
smaller
not
case, value
adjusted onthe the
of
equipment. greater
reselection
this the
parameter impact
is
modification has no and cell
reselection-related Default/Recommen
of mobility
smaller.
results
reselectionsin astategreater
arenot on V100R001C00 Radio
impact on the parameters
A smaller valueare of ded
The parameter the
impact
more reselection.
of the
difficult UE
to
equipment. adjusted
this parameterand cell
modification has no mobility
trigger.
reselectionsAstate
smaller on
are Default/Recommen
results in a greater V100R001C00 Radio
impact on the Qhyst, ofthat
thisis,toa
value difficult
more ded
The parameter
equipment. impact
larger of the UE of
probability
parameter
trigger. Astate leads to
smaller
modification has no mobility
cell
The reselection.
greater the onA Default/Recommen
the opposite
value of this effect. V100R001C00 Radio
impact on the Qhyst,
larger
parameter,
The that
valueleads
greater is, a
leads
the
the ded
The parameter
equipment. parameter
larger probability to
of
modification has no to aopposite
easier smaller
parameter,
the to trigger impact.
theeffect.the
cell
None reselection.
inter-frequency
more difficult forinter A the V100R001C00 Radio Engineering Design
impact on the larger value leads
The parameter
equipment. -RAT
cell tocellmeet the S
modification has no to
A a smaller
smaller
measurement.
criterion, value
the impact.
more of
The Default/Recommen
this
A parameter
largerfor value V100R001C00 Radio
impact on the smaller
difficult the the of cell ded
The parameter
equipment. indicates
this
to parameter
parameter,
become a Suitable
lower
the
modification has no frequency
indicates
moreThe
Cell. a
difficultofhigher
the
to
difficulty Default/Recommen
V100R001C00 Radio
impact on the reselection
probability
trigger the
level of the cell ofto
inter-aaUE low ded
The parameter
equipment. priority inter-
camping
frequency
selection on the
isinter-RAT
modification has no frequency/inter-RAT Default/Recommen
cells assigned
cell measurement.
increased. Thewith V100R001C00 Radio
impact on the cell. ded
The parameter the same
smaller thefrequency
equipment.
modification has no as the serving
parameter, the one, Default/Recommen
and a smaller value V100R001C00 Radio
impact on the easier for the cell to ded
The parameter
equipment. indicates
meet the S a lower
modification has no probability.
criterion, the easier
None V100R001C00 Radio Engineering Design
impact on the for the cell to
The parameter
equipment.
modification has no become Suitable Default/Recommen
With
None otherdifficulty
Cell. The V100R001C00 Radio
impact on the conditions ded
The parameter
equipment. level of the cell
modification has no unchanged,
selection is a larger
None of this
value V100R001C00 Radio Engineering Design
impact on the decreased. The
The parameter
equipment. parameter
selected cell indicates
should
modification has no a higherthe
provide probability
signal Default/Recommen
V100R001C00 Radio
impact on the of triggering
quality for theintra- basic ded
The parameter
equipment. frequency
modification has no services.
measurements,
None and V100R001C00 Radio Engineering Design
impact on the a smaller value
The parameter
equipment. When this value is
modification has no indicates a lower
increased,
None the V100R001C00 Radio Radio Planning
impact on the probability.
selection of the
The parameter
equipment. intra-frequency cell
modification has no A smaller more value of Default/Recommen
becomes V100R001C00 Radio
impact on the this parameter ded
The parameter difficult. When the
equipment. results
modification has no value isindecreased,
a greater
A smaller
None
impact value
of the UEof V100R001C00 Radio Engineering Design
impact on the the selection
The parameter this parameter
mobility state on the
equipment. becomes easier.
modification has no results in a greater
cell reselection time Default/Recommen
impact of the UE V100R001C00 Radio
impact on the within E-UTRAN, ded
The parameter
equipment. mobility state on
that is, results in a the
modification has no cell reselection
higher probability of time Default/Recommen
V100R001C00 Radio
impact on the within E-UTRAN,A
cell reselection. ded
equipment. that is,
larger valueresults in a
leads
higher probability
to a smaller impact. of
cell reselection. A
larger value leads
to a smaller impact.
The parameter
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning
The parameter
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment. When other
modification has no conditions remain
None V100R001C00 Radio Engineering Design
impact on the unchanged, an
The parameter
equipment.
modification has no increase in the
None
value of this V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment. parameter results in
modification has no A smaller value
a decrease in theof
this parameter V100R001C00 Radio Engineering Design
impact on the probability of
The parameter
equipment. results in a greater
reselection to the
modification has no A smaller
impact value
of the UEof
neighboring
None cell, V100R001C00 Radio Engineering Design
impact on the this parameter
mobility state oninthe
The parameter and a decrease
equipment. results
cell in a greater
reselection
modification has no the value resultstime
in Default/Recommen
impact
to of the UE
impact on the anCDMA2000
increase in the V100R001C00 Radio
ded
mobility
HRPD, stateis,on the
that
The parameter
equipment. probability.
cell reselection
results in a higher time
modification has no Default/Recommen
to CDMA2000
probability of cell V100R001C00 Radio
impact on the ded
The parameter HRPD, that is,
reselection. A larger
equipment.
modification has no results
value in
leadsa higher
to a
None
probability of cell V100R002C00 Radio Engineering Design
impact on the smaller impact.
The parameter
equipment. reselection. A larger
modification has no value
None leads to a V100R002C00 Radio Engineering Design
impact on the smaller impact.
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
equipment.
The parameter
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
equipment.
Not involved None V100R001C00 Radio Radio Planning
The parameter
modification has no A smaller value of Default/Recommen
None V100R001C00 Radio
impact on the this parameter ded
The parameter
equipment.
modification has no results in a greater
A smaller
None
impact value
of the UEof V100R001C00 Radio Engineering Design
impact on the this parameter
The parameter
equipment. mobility state on the
modification has no results in a greater
cell reselection time Default/Recommen
impact of the UEis, V100R001C00 Radio
impact on the to GERAN, that ded
The parameter
equipment. mobility
results instate on the
a higher
modification has no cell reselection time
probability of cell Default/Recommen
V100R001C00 Radio
impact on the to GERAN, that
reselection. is,
A larger ded
equipment. results in a higher
value leads to a
probability of cell
smaller impact.
reselection. A larger
value leads to a
smaller impact.
When other
conditions remain
unchanged, an
increase in the
Not involved None
value of this V100R001C00 Radio Radio Planning
The parameter parameter results in
modification has no a
A decrease
smaller value in the of Default/Recommen
V100R001C00 Radio
impact on the probability
this parameter of ded
The parameter
equipment. reselection to the
modification has no results in a greater
neighboring
impact of thecell,
A smaller
None value UEof V100R001C00 Radio Engineering Design
impact on the and a decrease
The parameter
equipment.
this parameter
mobility state oninthe
modification has no the
cell
A value
results
reselection
larger aresults
invalue greater in
oftime Default/Recommen
an increase
impact of the inUE the V100R001C00 Radio
impact on the to UTRAN,
this parameter that is, ded
The parameter
equipment. probability.
mobility
resultstoinstate
leads aalower on the
higher
modification has no cell reselection
probability of a celltime
cell Default/Recommen
V100R001C00 Radio
impact on the to
meeting criteria is,
UTRAN,
reselection. that
A larger
S ded
equipment. results
valuebecoming
and in a higher
leads to aa
Not involved probability
None
smaller cellof cell V100R001C00 Radio Radio Planning
A larger impact.
suitable value of
The parameter reselection.
selected by A larger
a UE. A
this parameter
modification has no value
smaller leads toof a this
leads tovalue
a higher V100R001C00 Radio
Default/Recommen
impact on the smaller
parameter impact.
results
probability
If this parameter of the isin ded
The parameter
equipment. a higher probability.
cell
set tomeeting criteria
modification has no Set thisbecoming
parameter Default/Recommen
S
A and
larger
BOOLEAN_FALSE value of a V100R001C00 Radio
impact on the properly so that the ded
suitable
this parameter
and cell
SI messages
equipment. selected cell
selected
results
contain in by
alarge
avalue acan
UE. A
smaller
Not involved None
A larger value
provide
smaller
number signals
of ofthat
of this V100R001C01 Radio Radio Planning
amount
this parameter of data to
The parameter meet
parameterthe
transmissions quality
resultsin a in
transmit,
results system
inprobability.
a smaller
modification has no requirement
a lower
unit of time andof a
information
A larger
number value
of may of not V100R002C00 Radio Engineering Design
impact on the basic
smaller services.
amount of
The parameter be
thisbroadcast
parameter
transmissions toin a
equipment. occupied system
modification has no each
results
unit of UE in
time in
a the
smaller
and cell
a Default/Recommen
resources,
A larger of
coverage.
number value
Inbut it
of
this V100R001C01 Radio
impact on the smaller amount of ded
The parameter may
this also
parameter
situation,
transmissions lead
cell in aa
to
edge
equipment. occupied system
modification has no longer
results
users
unit ofmay delay
in a not
time andin UE's
smaller Default/Recommen
resources,
A larger
acquisition
number value
of but
of ita
of
the V100R001C01 Radio
impact on the correctly
smaller receive
amount of ded
The parameter may also
this parameter
system
transmissions lead
information. in aa
to
equipment. system
occupied information.
system
modification has no longer
results
A smaller delay
in a in
smaller
value UE's Default/Recommen
unit
A of time
resources,
larger
acquisition
number value
of
andof
but
of the itof
a V100R001C01 Radio
impact on the this parameter
smaller amount of ded
The parameter may
this
system also
parameter
transmissions lead in
information. to aa
equipment. leads
occupied todelay
ansystem
modification has no longer
results
A smaller in a in
smaller
value UE's Default/Recommen
unit
A of time
opposite
resources,
larger
acquisition
number value
of
andof
effect.
but
of itof
the
a V100R001C01 Radio
impact on the this parameter
smaller quantity of ded
The parameter may
this
system also
parameter
transmissions lead
information. in aa
to
equipment. leads
system todelay
an
resources
modification has no longer
results
A smaller
unit of timein avalue
andin
smaller UE's
of
a Default/Recommen
opposite
occupied,
acquisition
number ofeffect.
but it may
of the V100R001C01 Radio
impact on the this parameter
smaller amount of ded
The parameter also
system lead
transmissions to a in a
information.
equipment. leads
occupied todelay
ansystem
modification has no longer
A smaller value in UE's Default/Recommen
unit of time
opposite
resources,
acquisition
and
effect.
but
of itof
the
a V100R001C01 Radio
impact on the this parameter
smaller amount ofa ded
The parameter may
system also lead
information to
equipment. leads
occupied todelay
ansystem
modification has no longer
in the SIB. A in UE's
smaller Default/Recommen
opposite
resources,
acquisition effect.
but
of it
the V100R001C01 Radio
impact on the A larger
value
To of value
guarantee this of
the ded
may
system also lead
information. to a
equipment. this parameter
parameter
throughput leads
ofinthe to
longer
A smaller delay value UE's
of
leads
an tocell,
opposite higher
Not involved None
serving
acquisition
A larger
this parameter value ofeffect.
set ofthis
the V100R001C00 Radio Radio Planning
The parameter throughput
parameter in
to a the
system
this
leads toinformation.
parameter an total
modification has no cell
large but lower
value. To of Default/Recommen
A smaller
leads
opposite to highervalue
effect. V100R001C00 Radio
impact on the throughput
guarantee in the
the total ded
this parameter
throughput in the
The parameter
equipment. entire
throughput network. of theA
leads
cell buttoloweran total
modification has no smaller
network, value
set of this Default/Recommen
impact on the
opposite
throughput
parameter inthis
effect.
leads theto V100R001C00 Radio
ded
The parameter parameter
entire network. to a A
equipment. lower
small
The throughput
value.
PUCCH power in
modification has no smaller
the cell valuealso
and of this Default/Recommen
is set on the basis V100R001C00 Radio
impact on the parameter
lower leads to ded
The parameter
equipment. of thisinterference
lower parameter in
throughput
modification has no to
The
for neighboring
PUCCH
the specific cells,
power Default/Recommen
the
is cell
resulting
set on andin
the also
higher
basis V100R001C00 Radio
impact on the PUCCH
lower format to
interference ded
The parameter
equipment. total
of thisthroughput
guarantee parameterthe cells, in
modification has no to
the
for neighboring
entire
the network.
specific Default/Recommen
PUCCH
resulting in higher V100R001C00 Radio
impact on the PUCCH
performance. format to ded
equipment. total
guarantee the in
throughput
the
PUCCH entire network.
performance.
When
The PUCCH power
DeltaPreambleMsg
is is
3 setset
ontothe
anbasis
The parameter of this parameter
excessively low
modification has no The
for the
value, PUCCH TXpower
specific
the power Default/Recommen
is set on format
the of
basis V100R001C00 Radio
impact on the PUCCH
requirement to ded
The parameter
equipment. of this parameter
guarantee
Message3 the
cannot
modification has no The
for PUCCH
the specificpower Default/Recommen
PUCCH
be
is met,
set onthe
theTXbasis V100R001C00 Radio
impact on the PUCCH format
performance.
power of the datato ded
The parameter
equipment. of this
guaranteeparameter
the
modification has no channel
for is
the specific Default/Recommen
PUCCH
decreased, andtothe V100R001C00 Radio
impact on the PUCCH format
performance. ded
The parameter
equipment. cell throughput
guarantee the falls.
modification has no When
PUCCH Default/Recommen
V100R001C00 Radio
impact on the DeltaPreambleMsg
performance. ded
equipment. 3 is set to an
Not involved excessively
None high V100R001C00 Radio Radio Planning
The parameter value, the TX power
modification has no exceeds the Default/Recommen
None
requirement of V100R001C00 Radio
impact on the ded
The parameter
equipment. Message3 and
modification has no causes interference Default/Recommen
None V100R001C00 Radio
impact on the to the neighboring ded
The parameter
equipment. cells. This
modification has no decreases the Default/Recommen
None V100R001C00 Radio
impact on the throughput of the ded
The parameter
equipment.
modification has no entire network. Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
equipment.
Not involved None V100R001C00 Radio Radio Planning
The parameter
modification has no
None V100R001C00 Radio Radio Planning
impact
The on the
parameter
equipment.
modification takes
effect after the cell None V100R001C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Engineering Design
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R002C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
Default/Recommen
effect after the cell None V100R001C00 Radio
The parameter ded
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Radio Planning
is automatically
reset.
The parameter
modification takes
effect after the cell None V100R001C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Radio Planning
is
Theautomatically
parameter
reset.
modification has no Default/Recommen
None V100R001C00 Radio
impact
The on the
parameter ded
equipment.
modification takes
Default/Recommen
effect after the cell None V100R001C00 Radio
The parameter ded
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Engineering Design
is automatically
The parameter
reset.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the
The parameter ded
equipment. takes
modification
effect after the cell None V100R001C01 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C01 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C01 Radio Radio Planning
is automatically
The parameter
reset.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact
The on the
parameter
equipment.
modification takes
effect after the cell None V100R001C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R001C00 Radio Engineering Design
The parameter
is automatically
modification
reset. takes
Default/Recommen
effect after the cell None V100R001C01 Radio
The parameter ded
is automatically
modification
reset. takes
effect after the cell None V100R001C01 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R003C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R003C00 Radio Radio Planning
The parameter
is automatically
modification
reset. takes
effect after the cell None V100R003C00 Radio Radio Planning
is automatically
reset.
Not involved None V100R001C00 Radio Not involved

Not involved None V100R001C00 Radio Not involved

Not involved None V100R001C00 Radio Not involved

Not involved None V100R001C00 Radio Not involved

Not involved None V100R001C00 Radio Not involved


Not involved None V100R001C00 Radio Not involved

Not involved None V100R002C00 Radio Not involved

Not involved None V100R001C01 Radio Not involved

Not involved None V100R001C01 Radio Not involved


A larger value of
this parameter
Not involved None
leads to greater V100R001C00 Radio Not involved
power consumption
Not involved of
Nonethe UE, but V100R001C00 Radio Not involved
A larger value
improves the of
this parameter
throughput of cell
Not involved leads
None
edge to less(CEUs)
users V100R003C00 Radio Radio Planning
A larger value of
measurement
The parameter more
this effectively in
parameter
reports,
dynamic which
ICIC will
modification has noleads to higher Default/Recommen
affect
mode. the prompt V100R003C00 Radio
impact on the estimation accuracy ded
The parameter update
A smaller of value
UE of
equipment. of interference from
modification has nolocations
this parameterand the Default/Recommen
neighboring
average cells,
throughput V100R003C00 Radio
impact on the A largeto
leads value
less of this
power ded
The parameter better
of service
cell edgeleads users
equipment. parameter
consumption of to
the
modification has noquality
(CEUs). and larger Default/Recommen
a
UE,low probability
but affects
average throughput of
the V100R003C00 Radio
impact on the triggering a DL ded
The parameter timely
of cell tracing
edge UEsofICIC
equipment. measurement event
modification has noneighboring
(CEUs). cells Default/Recommen
None
and hence
forlarger
A CEUs. Ina this
value small
of V100R003C00 Radio
impact on the ded
The parameter
equipment. number
situation,
this ofthe
parameter UEs that
modification has noreport thea related
interference-
leads to lower Default/Recommen
None
A larger value ofAs V100R003C00 Radio
impact on the measurements.
inducing
probability of both ded
The parameter
equipment. this
a parameter
result, the service
neighboring
triggering a DLcellICIC
modification has noresults Default/Recommen
cannot in
qualities
measurement acorrectly
lower
beprovided event V100R003C00 Radio
impact on the probability
for CEUs of
may not ded
The parameter determined,
and stopping which
the
equipment. meeting
modification has nobe
event. A the
mayguaranteed,
affect the and
smaller Default/Recommen
entering
the
value cell or leaving
ofcapacity
throughput this gain for V100R003C00 Radio
impact on the ded
The parameter condition
and
CEUs andofleads
throughput
parameter the of
even DL
to
equipment.
modification has noICIC
CEUs
decrease
a measurement
higher may thebe
probability. Default/Recommen
event. A smaller V100R003C00 Radio
impact on the affected.
throughput for ded
equipment. value
A leads
them. value
small toofa this
Not involved higher
parameter
None probability.
results in V100R002C00 Radio Radio Planning
The parameter a high probability of
modification has notriggering a DL ICIC
None
measurement event V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment. and hence a large
modification has nonumber of UEs that Default/Recommen
None V100R002C00 Radio
impact on the report the related ded
The parameter
equipment. measurements. As
modification has noa result, more UEs Default/Recommen
None V100R002C00 Radio
impact on the may occupy the ded
The parameter
equipment.
modification has noedge frequency Default/Recommen
None and the
band V100R002C00 Radio
impact on the ded
The parameter
equipment. throughput of each
modification has noCEU may drop. Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
equipment.
The parameter
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment. A larger value of
modification has no Default/Recommen
None
this parameter V100R002C00 Radio
impact on the ded
The parameter results
A largerinvalue a larger of
equipment.
modification has no number
this
If the parameter
value of Gold- of this Default/Recommen
None
level V100R003C00 Radio
impact on the leadsservices
parameter to a larger is too and ded
equipment. hence
number
small, the higher
of Silver- usage
Not involved of
If
Nonesystem
the
level
admission valueresources
services of and
threshold this V100R001C01 Radio Radio Planning
by
henceGold-level
parameter more
is too low for the is too
system
The parameter
services.
small,
resources
handed-over theThis occupied may
modification has no If the value of this
affect
admission
by Gold-with
service the QoS
andQCIthreshold
Silver- of V100R001C01 Radio Engineering Design
impact on the parameter isratetoo
The parameter satisfaction
is too
level
1. In lowcase,
services,
this for the of
the
equipment. small, thewith
modification has no services
handed-over
If the
which
QoS
If the of value
may
valuethethreshold ofother
of
affect
existing this
this
admission
priorities.
service
parameter with If isthis
QCI
too of V100R001C01 Radio Engineering Design
impact on the the QoS
services
parameter cannot is too be
The parameter is
2. too
parameter
In this
small, low
thecase, for isratethe
set theto
equipment. satisfaction
guaranteed.
small, the of
modification has no handed-over
If
a
QoSthe
small
admission value
of value,
the ofother
existing
threshold this
services
If the
admission value with of
threshold thisof V100R001C01 Radio Engineering Design
impact on the service
parameter
however,
services
is too low with there
cannot is QCI
too isbe
The parameter priorities.
parameter
is too low Iffor
for isthisnew
too
the
equipment. 3.
no In
small, this
impact
guaranteed.
Gold-level thecase, on the
services the
modification has no parameter
large,
handed-over
A larger the value is set of to
QoS
admission
radio
If
of the
all of
value
QCIs. the
network existing
threshold
of
In this V100R001C01 Radio Engineering Design
impact on the a small
admission
service
this parametervalue,
with threshold
QCI of
services
is too
performance.
parameter
case, thecannot
low for is
Gold-levelnew
too be
The parameter
equipment. however,
is
4. too
In this
leads high
to a there
case, for
higher is
the
the
guaranteed.
Silver-level
large,
services the occupy services
modification has no no
A impact
larger
handed-over
QoS value on theofoftoo
of all of
smaller
probability
If the
admission
many
radio
value
QCIs. the
system
network
valueexisting
ofof
In this
threshold V100R001C01 Radio Engineering Design
impact on the this
serviceparameter
services
the
systemparameter withcannot
congestion. QCI be
leadsof
The parameter parameter
case,
is too
resources, the
high is
Gold-
for
and too the and
equipment. performance.
results
1. In this
guaranteed.
to
In a lower
this in a
case,
situation, higher the
the
modification has no large,
Silver-level
A larger
handed-over
Silver- the
and value services
Copper- of
probability
If the
admission
system
admission valueresource of
success
of this
threshold
threshold V100R001C01 Radio Engineering Design
impact on the occupy
this
service
level parametertoo
with many
QCI of
The parameter system
rate
usage
is too
system isservices
parameter
for new congestion.
low
and
high Copper-
resources, for
is
the
for too the
equipment. leads
2. In
cannot
If the to
this
valuebe a case,higher
admitted.
is QCI the
large,
modification has no services
large,
level
access
A larger the
services with
success
value of allof
handed-over
and
the
1.
Copper-level
probability
admission
This affects
system
admission oftheof
success
threshold V100R001C01 Radio Engineering Design
impact on the QCIs,
rate
this
service are which
parameter
services low.
withcannot may
QCIbe of
The parameter system
rate
access
resource
is too ishigh congestion.
low
success
usage for
for the and
equipment. cause
A
3. smaller
indicates
In
admitted.this excessive
avalue
case,
This higher of
the
modification has no In
the this
services
rates case, with
of admission
access
handed-over the the
QCI of
Silver-
success
service
this
affectsparameter
probability
admission the of
success
access V100R001C01 Radio Engineering Design
impact on the system
2.
or
rate
service are resource
Copper-level low.
with QCI of
and
rate
successhence
indicates
system is low aand
congestion.
rates affect
lower
for of the
The parameter
equipment. utilization
services
A smaller of valueall the
QCIs.
of
4.
the InQoSthis
probability
If the value case,
of the
ofis QCI the
modification has no services
Copper-level
access
If theparameter
this
admission
admitted value with
success of large,
success
services. this of V100R001C01 Radio Engineering Design
impact on the generating
the
3.
rate system
servicesare of all QCIs.
The parameter
parameter
results
rate
If the isvalue
congestion
resource inlow.
low afor
usage
islower
of too thisand
equipment. If
A the
smaller
large, value
thewith value of thisof
modification has no probability
services
parameter
indications
the access of
is
and QCI of
too
success
parameter
the
this parameter
parameter
admission is too
threshold V100R001C01 Radio Engineering Design
impact on the generating
4.
large,
therefore
rate are the alower higher
large,
results
leads
is too to inlow.
the
high ahigher for new
The parameter congestion
admission
A smaller threshold
value
equipment. access
admission
efficiency
probability
Gold-level
successof of loadof
threshold
services.
modification has no indications
is
thistoo
rate. high
parameter
If the andnew
for
value is
is too
control,
generating
In high
this case, but formay
the new V100R001C01 Radio Engineering Design
impact on the hence
Copper-level
results
small,
leads
A smaller toainahigher
an higher
excessive
lower
value of
The parameter Silver-level
cause
congestion
access a greater
success
equipment. access
services.
efficiency
number
probability
this parametersuccess
ofIn ofusers
of this
load
modification has no services.
fluctuation
indications
rate is low In in this
and
for the
Gold-
rate.
A smaller
case,
control,
may If
be
generating
results thethe
inbut
admitted, value
value
access
higher it also ofis V100R001C01 Radio Engineering Design
impact on the case,
QoS
hence
level the
satisfaction
a
services. access
higher
small,
this
success
leads an
parameter excessive
rate is low
The parameter
equipment. but
success
rate
access
A oftoGold-level
the
congestion
efficiency
larger
arate
load
success
value
of greater
control
load
is low
of
modification has no number
results
for
actions
indications
control, in
Copper-level
fluctuation of
are
but ausers
insmaller
not
and
may the
for
GBR
rate.Silver-level
services.
Ifbe the value is V100R001C01 Radio Engineering Design
impact on the this
might
taken
hence parameter
quantity
services.
QoS ofadmitted,
satisfaction
timely
a higher to
cause
services.
A larger
small, an greater
value
excessive of the
indicates
but the load a smaller
The parameter
equipment. resources
rate
A
relieve
access of Silver-level
smaller
fluctuation
parameter
number the
success
of incontrol
allowed
value
causes
users theof a
modification has no number
actions
to
GBR
thisbeparameter
congestion.
rate. of services
are
occupied
services.
If the not
In this
value by
QoS
smaller
might
that can
satisfaction
be impact
admitted,
be onis V100R002C00 Radio Engineering Design
impact on the taken
GBR
A larger
results
situation,
small,
rate in
services
of an in time
value
a
the lower
excessive
Copper-level to and
of
overall a
The parameter the
but QoS
the
released load by control
the
equipment. relieve
lower
this
probability
QoS
number
GBR the
admission
parameter
satisfaction
of users
services. of
modification has no satisfaction
actions
system are
and rate
not
results of
congestion.
success
leads ofto
switching
rate
might
A larger be the arate
from Inofof
smaller
existing
admitted,
value this
a V100R002C00 Radio Engineering Design
impact on the Gold-level
taken
in a the
lowerin time services
to
The parameter case,
GBR
impact
high-usage
services
but
this the
services,
on
parameterload overall
the
decreases QoS
control
equipment. and
relievehence
probability the lower
of
modification has no QoS
thereby
and
actions
causes thesatisfaction
satisfaction
indication causing
call
are
a to rate
a
drop
not
smaller low-a
of
efficiency
congestion.
congestion ofrelief.load
In thisof V100R002C00 Radio Engineering Design
rate
higher
usage
rate
taken of
Silver-level the
probability
inindication
increases. time existing
services
impact on the impact
control.
case,
A smaller theonIn thistoQoS
the
overall
value case,
of
The parameter
equipment. services
resource
and
about
relievelower
satisfaction GBR
the drops
waste.
efficiency
rate and
of
both
QoS
this the probability
satisfaction
parameter
modification has no the
A
of call
larger
load
services.
congestion.
Copper-level drop
value
control.
As Inrate
a of In
this
of
rateleaving
of
indicates the the
existing
aoverall
larger V100R001C01 Radio Engineering Design
impact on the rises.
this
result,
case, parameter
case,
services, thedrops
the the
but results
The parameter congested
services
number of state
services and
equipment. leads
probability
QoS
in lower to a
satisfaction larger
of
efficiency GBR
modification has no and
the
that the
call
can access
dropbeexisting rate
quantity
leaving
service
rate
of loadof the theof
admission
control. V100R001C01 Radio Engineering Design
impact on the success
rises.
released rate
by areIn
the
The parameter resources
congested
failure
services
this is
case,drops allowed
higher.state
both and
the
equipment. lower.
system and results
modification has no to
and
A
the be the
larger
call
probabilityoccupied
access
value
drop of rate ofby
in
GBR a parameter
success
this
rises. higher
services rate are and a V100R001C01 Radio Engineering Design
impact on the leaving the
probability
lower
results admission
lower. in a state ofhigher
equipment. congested
congestion
success
probability rate ofrelief
of
ping-
and the access
and
non-GBR
pong aeffect
higher services.
in call
terms
success rate are
drop
When
of rate.
resources
switchings
lower.
The
are priority
insufficient,
between theofhigh- thethis
Gold-level,
may cause
usage indication Silver-
a higher
level,
call
and drop
the and rateBronze-
low-usage in
level
non-GBR services services.
generating
usage the
but high
toindication
admission,
leads theof
probability
results
usage inafewer
higher
of
indication of
UL RBs,
protection
probability
congestion which
over
of may
relief. In
types
DL RBs, of pre-
which may
cause
resource
generating
the case ofexcessive
allocation
the low
emptable
cause service
excessive
admission,
is performed
usage
congestion, but
indication the
after of
and a
admission,lower butaccess
the
protection
the
DL admission
RBs,
services for
which
are may
success
protection rate of
resource
decision.
cause
released Infora
allocation
excessive
high-priority as load
users
resource
is performed
addition,
admission, allocation
whenbut after
the
The parameter control
by means action,
of and
pre-
is
theperformed
valueadmission
of the
protection forafter
modification has no therefore
emption. the
Thus, callthe
the admission
decision.
parameter Therefore, V100R001C01 Radio Engineering Design
impact on the resource isisusers
drop rate allocation
high-priority too
The parameter decision.
this
large,
is loadIncontrol
parameter
performed does
after
equipment. increased.
have worse
modification has no addition,
not affect
actions
the are
admission when
the the
taken the
A smaller
experience. value of V100R002C00 Radio Engineering Design
impact on the value
overall
more
decision.of the
QoS
slowly.Therefore,
The parameter this
A parameter
smaller value of
equipment. parameter
satisfaction
A smaller israte
too
modification has no
this
results
this in avalue
parameter
parameter higher of
has
large,
much.
this
no load control
parameter
obvious impact V100R001C01 Radio Engineering Design
impact on the probability
results in of
more
actions
A smaller
leads
on theto are
a
overall taken
value
higher QoS of
The parameter
equipment. congestion
types of pre- relief,
more
this slowly.
parameter
probability
satisfaction of rate.
modification has no but it
emptable may lead
service to
A
A smaller
leads value
to aswitchings
generating
smaller lower
the high
value of
of V100R001C01 Radio Engineering Design
impact on the frequent
and a higher
The parameter this parameter
probability
usage of
indication
equipment. this parameter
betweensuccess
access overloadof
modification has no leads to a
generating
UL higher
the low
andRBs,
leads
rate overloadabut the
oftohigh-priority
lower relief. V100R001C01 Radio Engineering Design
impact on the probability
A smaller
usage of
value
indication
satisfaction
probability of rates ofof
The parameter users
generating
this by means
parameter the of
high
equipment. UL
are resources
compared
generating the low
modification has no pre-emption.
usage
results indication
in blocks
fewer In this
of
resource
further
usage to make
indication of V100R001C01 Radio Engineering Design
impact on the case,
DL RBs the call
but drop
The parameter
non-GBR
and hence
admission
UL resources athe
services
lower
equipment. rate is higher.
satisfaction
that can be rates
modification has no admission
decisions.
resource success
blocks
are
rate,compared
admitted; a
but thethe
Therefore,
and hence larger
a lower V100R001C01 Radio Engineering Design
impact on the
further
value
parameter
admissionoffor
protection thisfor
has no
success
equipment.
admission
parameter
resource
obvious
rate, decision.
results
allocation
but impact
the onin
Not involved None
Therefore,
more non-GBR this V100R002C00 Radio Radio Planning
is performed
admission.
protection Inafter
for
The parameter parameter
services
the admission
addition, thathas
when can no
thebe
resource allocation
modification has no obvious
admitted.
decision.
value impact
of the Therefore, on
is performed
None after V100R002C00 Radio Engineering Design
impact on the admission.
this parameter
parameter In
is too has
The parameter the admission
equipment. addition,
no obvious
small, when
excessive impact the
modification has no decision. Therefore, Default/Recommen
value
None
on
this of the
admission.
overload
parameter control In
has V100R002C00 Radio
impact on the parameter isimpact
toothe ded
The parameter
equipment. addition,
actions
no obvious maywhen be
modification has no small,
value
resulted.
on excessive
of the In
admission. Default/Recommen
None
load control
parameter isactions
small, V100R002C00 Radio
impact on the addition, when the ded
The parameter
equipment. may
the be
load
value of the taken.
control
modification has no algorithm
parameter may
is small,
None V100R002C00 Radio Engineering Design
impact on the mistakenly
the load control trigger
equipment. the servicemay
algorithm release,
Not involved None
which
mistakenlywill causetriggera V100R002C00 Radio Radio Planning
The parameter rise in the call
the service drop
release,
modification has no rate. will cause a
which
None V100R002C00 Radio Engineering Design
impact on the rise in the call drop
The parameter
equipment. rate.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None
A larger value of V100R002C00 Radio
impact on the ded
equipment. this parameter
Not involved leads
None to less V100R003C00 Radio Radio Planning
A larger value of
measurement
The parameter this parameter
reports, which will
modification has no leads Default/Recommen
affect to
thehigher
prompt V100R003C00 Radio
impact on the estimation accuracy ded
The parameter update of UE
equipment. of interference from
modification has no locations and the Default/Recommen
neighboring cells,
average throughput V100R003C00 Radio
impact on the ded
better
of cell service
edge users
equipment.
quality
(CEUs).and larger
average throughput
of cell edge UEs
(CEUs).
edge users (CEUs)
more effectively in
dynamic ICIC
mode.
A smaller value of
this parameter
A large value of this
leads to less
parameter power
leads to
The parameter
consumption
a low probability of the
of
modification has no Default/Recommen
UE, but affects
triggering a UL ICICthe V100R003C00 Radio
impact on the ded
The parameter timely tracing
measurement event of
equipment.
modification has no neighboring
and hence acells small Default/Recommen
None
for
A CEUs.
larger In
value this
ofthat V100R003C00 Radio
impact on the number of UEs ded
The parameter situation,
equipment. this
report thethe
parameterrelated
modification has no interference-
leads to a lower As Default/Recommen
None
measurements.
A larger value of V100R003C00 Radio
impact on the inducing
probability ded
The parameter a result,
this theofservice
parameter
both
equipment. neighboring
triggering a UL cellICIC
modification has no qualities
results in provided
acorrectly
lower Default/Recommen
cannot
measurement
for be
CEUs may event
not V100R003C00 Radio
impact on the probability ofwhich ded
The parameter determined,
and
be stopping
guaranteed, theand
equipment. meeting the
modification has no may
event.
the affect
cell the
Acapacity
smaller Default/Recommen
entering
throughput
value of or leaving
this gain offor V100R003C00 Radio
impact on the and throughput ded
The parameter condition
CEUs
parameterand ofleads
the UL
even
equipment. CEUs
ICIC may be to
measurement
modification has no decrease
a higher the
probability. Default/Recommen
affected.
event. A smaller V100R003C00 Radio
impact on the throughput forof this ded
A small
value value
leads to a
equipment. RACH
them. resource
parameter
higher results in
probability.
Not involved adjustment
None switch: V100R002C00 Radio Radio Planning
a high probability of
The parameter If this switch is
triggering a UL ICIC
modification has no turned on, based on Default/Recommen
measurement
None event V100R002C00 Radio
impact on the the number of ded
and hence a large
The parameter
equipment. accessed UEs, the
number of UEs that
modification has no algorithm can
report
None the related V100R002C00 Radio Engineering Design
impact on the improve the
The parameter measurements. As
equipment. utilization of
modification has no a result, more UEs Default/Recommen
dedicated
None V100R002C00 Radio
impact on the may occupy the ded
The parameter preambles while
equipment. edge frequency
modification has no ensuring that the Default/Recommen
band
None and the cell V100R002C00 Radio
impact on the probability is less ded
capacity and
The parameter
equipment. than or equal to 1%
throughput of each
modification has no that a UE with the Default/Recommen
CEU
None may drop. V100R002C00 Radio
impact on the random access ded
The parameter
equipment. procedure triggered
modification has no by handover (case Default/Recommen
None V100R002C00 Radio
impact on the 3) or arrival of ded
The parameter
equipment. downlink data (case
modification has no If the switch is is Default/Recommen
None
4)
If is not allocated
SrsAlgoSwitch V100R002C00 Radio
impact on the
The parameter turned on, the ded
with a dedicated
enabled, SINR over
equipment. takes
modification PUCCH resources
preamble.
a wide band In can be Default/Recommen
effect after the cell None
are increased
addition, the orwill V100R003C00 Radio
obtained, which ded
is automatically decreased
algorithm can also
lead to a better
reset. adaptively
improve based on
Not involved None the of
performance V100R001C00 Radio Radio Planning
the load on
PRACH utilization
Adaptive the
The parameter PUCCH. This
while
Modulation andthat
ensuring
modification has no achieves betteris
the
Codingprobability V100R001C00 Radio Engineering Design
impact on the When a(AMC)
utilization PDCP
of equal
The parameter less than
during or
scheduling.
equipment. packet
PUCCH queue
resources is
modification has no toSrsAlgoSwitch
If 1% that multiple is
congested,
and reduces theUL V100R001C00 Radio Engineering Design
impact on the UEs initiate
disabled, only random
the
The parameter automatic
control packet
signaling
equipment. access
SINR over procedures
a narrow
modification has no discarding
overhead. When
triggered
band can by
be initial V100R001C00 Radio Engineering Design
impact on the mechanism
the PUCCH is
access
obtained. (case
In 1),
this
The parameter
equipment. started
resources if are
failed radio
case, if the link
modification has no AqmAlgoSwitch
decreased, is
(case
frequency 2), orselection
arrival V100R001C00 Radio Engineering Design
impact on the set to
however, ON. This
a few(case
of uplink isdata
function
The parameter
equipment. reduces
users may theenabled,
delay
need
modification has no 5)
bothwith the
the AMC same to
of interactive
None
reconfigure the CQI V100R001C00 Radio Engineering Design
impact on the preamble at the
performance and
The parameter services,
resources, but it
which
equipment. same time. will be
throughput
modification has no slightly
consumes increases
certain
Dedicated
affected.
None V100R001C00 Radio Engineering Design
impact on the the
DL time
resources.used to
preamble
The parameter
equipment. download
If the switch large-
is
multiplexing switch:
modification has no sized
turned files.
off, the
If the switch
None is UL V100R001C01 Radio Engineering Design
impact on the control signaling
turned on, the
equipment. overhead
shortage of is
relatively
dedicatedlarge.
preambles can be
relieved to a certain
extent.
Backoff control
switch: If this switch
processing
access the network more
services,
where spare services
are not diverted
resources are
from the local cell to
available.
the neighboring
LCEM_RAC_ALG_
cell. Thus, the
GBR_USAGE_SWI
The parameter probability
TCH: of
modification has no overload is
If this switch is set
relatively high, and V100R001C01 Radio Engineering Design
impact on the to OFF, GBR
The parameter
equipment. the access
services may success
modification has no If
rate and total
occupy excessive
FreqPriorIFHOSwitc V100R002C00 Radio Engineering Design
impact on the throughput
PRB resources are
The parameter
equipment. h is set tolow.
relatively On, Ifthe
modification has no because
frequency-priority-the
InterFreqMlbSwitch
None
scheduling V100R002C00 Radio Engineering Design
impact on the based
is set tointer- ON, the
The parameter
equipment. algorithm
frequency handover
modification has no inter-frequency
preferentially
is
None
MLB enabled.
function It is V100R002C00 Radio Engineering Design
impact on the guarantees
improves the thedata
The parameter
equipment. enabled.
GBRs of Then,
GBR in
modification has no rate
the of
case the thatUE at
the
services
None
the expense (except of anthe V100R002C00 Radio Engineering Design
impact on the cell
IP load is heavy
Multimedia
The parameter
equipment. increased
and there is number
an
modification has no Subsystem
of handovers. [IMS]
To
imbalance
None
signalings). in As thea V100R003C00 Radio Engineering Design
impact on the speed
cell loads,up handover,
the
The parameter
equipment. result,
you the
are advised to
probability
admission of
modification has no set both issuccess
None
overload V100R003C00 Radio Engineering Design
impact
The on the
parameter rate is relatively low,
FreqPriorIFHOSwitc
equipment. relatively
and the low, and
number of
modification takes h
theandaccess success
UEs in the cell is Default/Recommen
effect after the cell None
FreqPriorIFBlindHO
rate and total V100R003C00 Radio
relatively ded
is
Theautomatically
parameter Switch
throughput to small.
On. are In
reset.
modification has no If this
addition, switch to is set
ensure Default/Recommen
relatively
to ON, thesuccess high.
limitation V100R003C00 Radio
impact on the handover
If UtranMlbSwitch, ded
equipment. of PRB
rate, strictly setisthe
usage
GeranMlbSwitch
applied to GBR or
Not involved triggering
None
CdmaMlbSwitch V100R001C00 Radio Radio Planning
The parameter services.
conditions As oftheathe is
set to
result, OFF,
the
modification takes frequency-priority-
corresponding inter-
effect after the cell admission
None
based inter- success V100R001C00 Radio Engineering Design
RAT
rate MLB
and handover function
is automatically frequency
is disabled. Then,
reset. success
handover; rate forare
Not involved the
None corresponding
relatively high, but V100R002C00 Radio Radio Planning
example,
inter-RAT set
load the
The parameter there might
threshold related be a to
imbalances
waste of cannot
resources.
modification has no event A1 to aInlarge Default/Recommen
None
be handled.
LCEM_RAC_ALG_ this V100R002C00 Radio
impact on the value. As an ded
case, the
DL_LDC_SWITCH: probability
equipment. advantage, this will
of
If overload
this switch isis set
Not involved None
decrease
relatively the
high and V100R001C00 Radio Radio Planning
to OFF,
number downlink
of UEs that
The parameter the access success
overload
will be handedcheck is
over
modification has no rate and total Default/Recommen
None
not
to performed
high-priority and
cells V100R001C00 Radio
impact on the throughput ded
The parameter hence
and load are
potentially control
equipment. relatively low. If
modification has no actions
increase are thenot loads Default/Recommen
None
UtranMlbSwitch,
taken when the V100R001C00 Radio
impact on the in low-priority cells. ded
GeranMlbSwitch
downlink load in the or
equipment.
CdmaMlbSwitch
cell is heavy. As a is
Not involved None
set to ON, the drop V100R001C00 Radio Radio Planning
result, the call
The parameter corresponding
rate is relativelyinter-
modification has no RAT
If thisMLB parameter function is Default/Recommen
high,
None and the V100R001C00 Radio
impact on the is
set enabled.
to On, theThen, in ded
service satisfaction
equipment. the
ratecase
eNodeB that thelow.
performs
is relatively
Not involved load
None in the
differentiation
A larger
If this switchvalue cellisofis
set V100R001C00 Radio Radio Planning
The parameter heavy
control and
to ON, downlink the
this between
parameter there is
modification has no an
BT inter-RAT
service
indicates
overload a and
check larger the
is
None
imbalance
non-BT service in theloadthat V100R001C00 Radio Engineering Design
impact
The on the
parameter amount
performed of and
equipment. takes
modification load
are
resourcesbetween
carried
control actions by cells,
the
allocatedare
effect after the cell the
to
taken
None probability
non-GBR
non-BT in the link. of of
In
services.
case V100R003C00 Radio Engineering Design
is automatically overload
this
A case,
overload. As a of
smaller in when
valuethe
The parameter system ishighrelatively
reset. traffic
this
result, isthe
parameter callindropa
modification has no low,
impact on the rate and
cell, the data
indicates
due the
to access
a smallerrate of
service V100R001C00 Radio Engineering Design
The parameter success
the BT service
amount.
releases rate
is and on
equipment. total throughput
modification has no the air
Adjustment interface
relatively high. of the can
are
be relatively
effectively high. V100R001C00 Radio Engineering Design
impact on the parameter
LCEM_RAC_ALG_ value will
equipment. controlled
affect the on the
UL_LDC_SWITCH:
basis
If this of
throughput switchtheinuser- isa set
cell.
defined
Whether
to OFF, uplink priority,
the
thereby
overloadpreventing
throughput check will is
the
not BT
increase service
performed or from
and
severely
decrease
hence load impacting
depends
control
on
on other
the
actions services
distribution
are not in
The value of this
parameter has an
obvious impact on
The
The value of
value
intra-frequency of this
thisload
parameter
parameter
balancing. If this has
has an
an
obvious
obvious
parameter impact
impactis seton on to
inter-frequency
inter-RAT
a large value, loadintra- load
Not involved None
balancing. If V100R002C00 Radio Radio Planning
balancing.
frequency cell If this
thisloads
The parameter parameter
parameter is
is set to
set to
may not yet reach
modification has no a
a large
large value,
value, inter-
inter-
the optimum V100R002C00 Radio Engineering Design
impact on the frequency
RAT cell when cell loads
loads may
The parameter balance
equipment. may
not notreach
yet yet reach
the If
modification has no overload occurs.
A
thesmaller
optimum
optimum value of
balance V100R002C00 Radio Engineering Design
impact on the this
If thisparameter
parameter is is
The parameter this
balance
when parameter
when
overload may
equipment. set to
set to aa large
small value, value,
modification has no cause
overload
occurs. frequent
If occurs.
this loadIf
however,
a load balancingexcessive V100R002C00 Radio Engineering Design
impact on the updates
this parameter
parameter and is induce
set is to
handovers
action and
maysignaling
not be
The parameter
equipment. excessive
set
a to a value,
small small value,
signaling
taken timely when
modification has no overhead.
however,
however, A larger
excessive
excessive Default/Recommen
exchanges
the cell load mayis be V100R002C00 Radio
impact on the value
handovers
inter-RAT
If this of thisand
parameter is ded
The parameter resulted.
unbalanced,
The value of or
thismay
equipment. parameter
signaling
handovers
set to astopped
large may
may be
value,
modification has no not be
parameter
hinder thewhich cell to Default/Recommen
exchanges
resulted,
load balancing may be
may
may V100R002C00 Radio
impact on the timely
determines
timely when
obtain the
whether
the cell ded
The parameter resulted.
deteriorate
not be initiated the or
equipment. load
to
load is
perform balanced.
status of theIfIf
dynamic
modification has no system
stopped
this parameter
adjustment in time.
ofcells.is
the Default/Recommen
neighboring V100R003C00 Radio
impact on the performance
this
set
ratioto smallsince
parameter
ofa CCEs is
value, ded
equipment. the
set
The inter-RAT
to a small
setting
however,
assigned a of
toloadUL value,
theand
Not involved handover
load
Nonebalancing
switch
balancing
those has
determines
assigned action amay low
to V100R003C00 Radio Radio Planning
The parameter success
be initiated
whether
mayonbethe
DL rate. and
toPDCCH.
perform
frequently
modification has no stopped
taken or frequently.
dynamic
Changing stopped.
the value
adjustments V100R003C00 Radio Engineering Design
impact on the of this parameter
Changing theon the
value
The parameter
equipment. number
affects of
the OFDM
number
of this parameter
modification has no symbols
of CCEs occupied
assigned
affects the V100R003C00 Radio Engineering Design
impact on the by
to ULPDCCH.
or DL. IfInthe this
The parameter scheduling
equipment. switch
case, the is turned
number off,
of
modification has no throughput in DL.
uplink and
scheduled users as downlink V100R003C00 Radio Engineering Design
impact on the A larger value ofbe
throughput
well as the may
equipment. this parameter
affected
throughput when in UL or
Not involved None
leads V100R001C00 Radio Radio Planning
DL areto
CCEs are less
also
The parameter available
affected. SRI
insufficient, or
modification has no resources.
downlink Default/Recommen
V100R001C01 Radio
impact on the A smaller value
throughput may of be ded
equipment. this parameter
affected when
Not involved leads
None to
CCEs are more V100R001C00 Radio Radio Planning
The parameter available
excessive.SRI
modification has no resources. Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
equipment.
Not involved None V100R001C00 Radio Radio Planning
The parameter
modification takes
effect after the cell None V100R001C00 Radio Engineering Design
is automatically
reset.
Not involved None V100R001C00 Radio Radio Planning
The parameter
modification has no Default/Recommen
None V100R001C01 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
equipment.
Not involved None V100R001C01 Radio Not involved
Not involved None V100R001C01 Radio Not involved

Not involved None V100R001C01 Radio Not involved

If the length of the


Not involved None
default paging cycle V100R001C01 Radio Not involved
is fixed, a larger
value of this
Not involved None V100R001C01 Radio Not involved
parameter results in
a longer
Not involved The
Nonesetting ofperiod
modification this V100R001C01 Radio Not involved
parameter
and a larger affects
the
number coverage of times of the
Not involved 1)
None
PCFICH
that Coverage: are If theA
UEs channel. V100R001C00 Radio Radio Planning
The parameter value
larger of
value ofthis
this
required
The setting to readof
modification takes ReferenceSignalPw
parameter leads
system information affectsto Default/Recommen
effect after the cell ra isbetter
too large,
coverage cross- V100R001C00 Radio
change
the coverage area ded
is automatically The
coverage
performance,setting ofwhich
occurs. this
but
notifications,
of the PBCH
reset. parameter
This
induces causes affects
stronger
Not involved leads
channel.
None to higher
A larger V100R001C00 Radio Radio Planning
the coverage
interference
radio
reliability
value of to
interference
of this to
The parameter performance
other cells. of
thethein
Ifcells.
neighboring
acquiring such
parameter results
modification has no SCH channel. Default/Recommen
value
This
notifications.
better of
causes
coverage aAA V100R001C00 Radio
impact on the larger ded
The parameter
equipment. longer value
ReferenceSignalPw
waste
performance, of power
modificationofbut
this
and it
modification has no parameter
rinduces
is too small,
reduces
period, theresults
however,
strongeramount in Default/Recommen
better
coverage
of power coverageholes V100R001C00 Radio
impact on the results
interference in available
a longer
to ded
The parameter
equipment. performance,
appear.
for
delay theinPHICH
neighboring changing but
andit
cells
modification has no induces
2)
PDCCH Interference:
the system
and stronger
may cause The
channels. a A Default/Recommen
V100R001C00 Radio
impact on the interference
setting
smaller
information.
waste ofofvalue
power. toof A this ded
The parameter
equipment. neighboring
modification has no
ReferenceSignalPw
parameter,
smaller valuecells of this Default/Recommen
randvaries
however,
None
parameter,maywith cause
may the a
lead V100R001C00 Radio
impact on the waste
interference of power. from A ded
The parameter to insufficient
however, may lead
equipment. smaller
modification has no to insufficient this
neighboring
coverage value
and of
cells. A Default/Recommen
None
parameter,
large
coverage interference
holes. V100R001C00 Radio
impact on the coverage and ded
The parameter
equipment. however,
margin
coverage is may
required
holes. lead
modification has no to insufficient
where the Default/Recommen
None V100R001C00 Radio
impact on the coverage and
interference is ded
The parameter
equipment. coverage holes.
strong.
modification has no 3) Channel Default/Recommen
None V100R003C00 Radio
impact on the A larger value
estimation: of Pb
A larger ded
equipment. results
value ofin a larger
Not involved increase
None
ReferenceSignalPw in V100R001C00 Radio Radio Planning
When this
ReferenceSignalPw
The parameter r leads to higher
parameter
r, better channel is set to
modification has no channel estimation Default/Recommen
a relatively
estimation great V100R001C00 Radio
impact on the accuracy, a lower ded
The parameter value,
performance, the
equipment. demodulation and
modification has no throughput
better PDSCH of this Default/Recommen
threshold,
A larger and of
value V100R001C00 Radio
impact on the cell is increased.
demodulation ded
higher
this receiver
parameter
equipment. The throughput
performance, of
sensitivity,
leads to butbut
higher it it
Not involved the
also
None whole
leads network,
to lower V100R001C00 Radio Radio Planning
causes
throughput stronger
however,
transmit is in the
power of
The parameter interference
cell but lower tototal
reduced.
the PDSCH When (type this B)
modification has no neighboring
throughput cells. Default/Recommen
parameter
and thus isinset
increases
theto V100R001C00 Radio
impact on the 4) Capacity:
entire network. A A ded
The parameter a
the relatively
rate lessedge
of cell
equipment. larger
smaller value
value ofof this
modification has no value,
users. the Default/Recommen
ReferenceSignalPw
parameter
impact on the interferenceleads on the to V100R001C00 Radio
ded
rlower
brings better
equipment. neighboring cells in
throughput is
coverage,
the cell and but alsoa
Not involved reduced.
None value Thus, the V100R001C00 Radio Radio Planning
large
lower interferencelimits
The parameter throughput of this
theneighboring
to power usedcells, for
modification takes cell is reduced and
the
which transmission
thereby of
effect after the cell that
None of the whole V100R001C00 Radio Engineering Design
data
results and hence
is automatically networkinishigher
decreases
total throughput the in
reset. increased.
system
the entire capacity.
network.
Set
ReferenceSignalPw
r appropriately to
ensure a
reasonable tradeoff
The parameter
modification takes The values of this Default/Recommen
effect after the cell None
parameter and theto V100R001C00 Radio
As a supplement ded
is automatically NB parameter
planning of base
reset. determine theof this
Not involved sequence
A
Nonelarge value groups V100R001C00 Radio Radio Planning
The parameter number
for UL RS
parameter of paging
indicates
modification takes occasions,
generation,
a large amount that
group is,
of Default/Recommen
effect after the cell None
the
hoppingnumber
occupied control of
simplifies V100R001C00 Radio
The parameter ded
is automatically paging
the
channelplanning groups.
resources and A
modification
reset. takes larger
randomizes value UL of this RS
and a small Default/Recommen
effect after the cell When
parameter may V100R001C00 Radio
correlation
constraint on thelead ded
is automatically GroupAssignPUSC
to a longer
interference. delay inA
uplink scheduling.
reset. H of
paging
Though all acells
UE
the under
but
current
Not involved small
For
None a value
certainof this
paging V100R001C00 Radio Radio Planning
The parameter one
load, a largerisvalue
help
group eNodeB
parameterreduce
hopping the
indicates set
can
modification takes to
power0, the
significantly
a small
of UL
consumption
amount
this parameter RSs
reduce andon
the PUSCHs are Default/Recommen
effect after the cell of
the
a the UE.
probability
great
indicates
When aAlarger
constraint.
group smaller
of V100R001C00 Radio
The parameter generated on the ded
is automatically value
collisions
paging
hopping of this
that
capacity
is not
modification takes basis
reset. duringofa different
parameter
neighboring
performed, may
specific cells lead Default/Recommen
effect after the cell base
to
use a sequence
shorter
the same delaybase in V100R001C00 Radio
period, andhopping
sequence a ded
is automatically groups.
paging
sequence aInUE thisbut
group in
smaller
can beeach value
supported. of this
reset. case,
cause
a TTI,base itmore
cannot cell
power can
Not involved parameter
None
After indicates V100R001C00 Radio Radio Planning
use any
consumption Cyclic Shift
The parameter completely
a
(CS)
smaller paging
sequencesvalue are the
of
prevent
during
modification takes UE.
such
divided If the
collisions.
capacityinto EPC
during groups, a
the generation Default/Recommen
effect after the cell specifies
None
a) When
specific
the base a DRXof
the
period. V100R001C00 Radio
The parameter the UL for RS. The ded
is automatically period
number
sequences ofacells UE, isthe
within
modification
reset. takes more
UE
smallerusesthe available
the
than smaller
30, the
each group the have Default/Recommen
effect after the cell None
CS
value
reuse values,
between
of base the V100R001C00 Radio
The parameter great correlations ded
is automatically more
period
sequence the and V-MIMO
the
groups
modification
reset. takes (the
users basethatoccur. can be
parameter value Default/Recommen
effect after the cell does
None
sequences
matched.
not are Inas V100R001C00 Radio
The parameter its
this
When DRX
case,all period.
group as
cells ded
is automatically almost
When regarded
modification
reset. takes hopping
under
identical). one is not
eNodeB
The
effect after the cell GroupAssignPUSC
required.
use the sameTherefore, base V100R001C00 Radio Engineering Design
correlations
H
is
Theautomatically
parameter isofrecommended
between
cells under
itsequence a group
base
one
to
reset. eNodeB
that
generategroup isUL setRSs
hopping to
modification has no sequence in group
different
be
on disabled.
PUSCHs, values, the V100R001C00 Radio Engineering Design
impact
The on the
parameter A and the base
UL
b) RSs onthethe
When CyclicShift
different
equipment.
modification takes sequences in be group
PUSCHs
number
values ofcan
need cellsto be
effect after the cell B are
generated similar onthe tothe V100R001C00 Radio Engineering Design
is automatically exceeds
set forbetween
those these30, cellsany
The parameter basis of the same
reset. reuse
so
other ofthe
thatbase base cells use
modification has no base sequence. Default/Recommen
sequence
different
sequence groups
cyclic
in group shifts V100R001C00 Radio
impact on the Thus, the ded
The parameter might
during
A and occur.
thesemi- base
equipment. orthogonality of UL
modification has no Though
persistent
sequences planningin group
RSs
None
can between
be
scheduling. performed V100R001C00 Radio Engineering Design
impact on the B. Thus, sequence
neighboring
to
When prevent theiscells cells
equipment. hopping
can be
neighboring slightly
Not involved under
equivalent
None
improved.
one eNodeB tocells
In the V100R001C00 Radio Radio Planning
The parameter from
use
use using
different
of an the base
identical
modification takes addition,
same
sequence base togroups
ensureto
base sequence
orthogonality of in UL Default/Recommen
effect after the cell sequence
generate
None TTI,UL
each group,
which RSs V100R001C00 Radio
RSs
the between
planning is cells, ded
is automatically on
does PUSCHs,
not of result set in
reset. only part
complicated
CyclicShift to the 0.CS
when
Not involved an
values
None obvious area available V100R002C00 Radio Radio Planning
there
difference are largethat
from
for
numbereach cell.
of cells.Thus, In
when
the sequence
number of
Not involved this
hopping
None case, is itnotis V100R003C00 Radio Radio Planning
available
recommended CS values that
performed.
decreases and be the
group
Therefore, hopping it is
Not involved number
enabled
None of
to V-MIMO V100R003C00 Radio Radio Planning
recommended
users that can that
be
randomize
sequencealso UL RS
hopping
matched
interference
Not involved be
None disabled. and
decreases. V100R001C00 Radio Radio Planning
prevent
complicated
planning.
Not involved None V100R001C00 Radio Radio Planning
The parameter
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
equipment.
Not involved The
Noneentering V100R002C00 Radio Engineering Design
condition for event
The parameter B1 is as follows: Mn
modification has no + Ofn - Hys >
None V100R003C00 Radio Engineering Design
impact on the Thresh.
The parameter
equipment.
modification has no Where Mn is the
None
measurement value V100R003C00 Radio Engineering Design
impact on the
equipment. of neighboring cells,
Ofn is the
Not involved None V100R001C00 Radio Radio Planning
frequency-specific
offset of the
Not involved neighboring
None cell, V100R001C00 Radio Radio Planning
Thresh is the
threshold for this
Not involved None
event, and Hys V100R001C00 Radio Radio Planning
The parameter refers to the
modification has no hysteresis for this
V100R001C00 Radio Engineering Design
impact on the event.
The parameter
equipment. A smaller value of
modification has no Ofn leads to lower
None V100R001C00 Radio Engineering Design
impact on the probabilities of
The parameter
equipment.
modification has no triggering both
None B1 and
event V100R001C00 Radio Engineering Design
impact on the
equipment. handover, which
may affect user
Not involved None V100R002C00 Radio Radio Planning
experience. A larger
value of Ofn leads
Not involved to
Nonea higher V100R002C00 Radio Radio Planning
probability of
triggering event B1,
Not involved None may cause
which V100R002C00 Radio Radio Planning
more decision
errors and ping-
Not involved None
pong handovers. V100R002C00 Radio Radio Planning

Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R002C00 Radio Radio Planning

Not involved None V100R002C00 Radio Radio Planning

Not involved None V100R002C00 Radio Radio Planning

Not involved None V100R002C00 Radio Radio Planning

Not involved None V100R003C00 Radio Radio Planning


Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R002C00 Radio Radio Planning

Not involved None V100R002C00 Radio Radio Planning

Not involved None V100R002C00 Radio Radio Planning

Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R003C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R002C00 Radio Engineering Design
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning
A larger value of
this parameter
Not involved None
indicates
A a higher
larger value of V100R001C00 Radio Radio Planning
The parameter probability
this parameterof a UE
modification has no camping
leads to aon the
lower
A V100R001C00 Radio Radio Planning
impact on the probability of aof
larger
cells value
assigned with
UE
The parameter
equipment. this parameter
the band class, and
camping on a cell
modification has no leads to avalue
a smaller lowerin
on a frequency V100R001C00 Radio Radio Planning
impact on the probability
indicates a of a UE
lower
The parameter the higher-priority
equipment. camping
probability.on a cell
modification has no CDMA2000 band
on a frequency in
class, and a smaller V100R001C00 Radio Radio Planning
impact on the
the
valuelower-priority
leads to a
equipment.
CDMA2000
higher band
probability.
Not involved None
class, and a smaller V100R001C00 Radio Radio Planning
value leads to a
Not involved higher
None probability. V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
equipment.
The parameter
modification has no
None V100R002C00 Radio Engineering Design
impact on the
equipment.
Default/Recommen
Not involved None V100R002C00 Radio
ded
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None
A larger value of V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment. this parameter
modification has no indicates a higher
None V100R001C00 Radio Engineering Design
impact on the probability
A larger value of aofUE
The parameter
equipment. camping
this on a cell
parameter
modification has no
on a entering
leads
The frequency
to a lowerin V100R001C00 Radio Engineering Design
impact on the
The parameter the GERAN
probability
condition carrier
ofofevent
a
equipment.
modification has no frequency
neighboring
B1 group,
is as follows: cell on Default/Recommen
None
and
a
Mn +aother
smaller
frequency
Ofn - Hysinvalue
the
> V100R001C00 Radio
impact on the With ded
The parameter
equipment. indicates
GERAN
Thresh.
conditions a lower
carrier
modification has no probability.
frequency
None Mngroup
Where,
unchanged, isa the
larger V100R001C00 Radio Engineering Design
impact on the With
becoming other
value of this suitable
measurement a value
The parameter
equipment. conditions
cellneighboring
of for cell leads
parameter cells.
to
modification has no unchanged, a larger Default/Recommen
selection.
Ofn
a is the
lower A smaller
probability V100R001C00 Radio
impact on the value of this to a ded
The parameter frequency-specific
of reselection
equipment. parameter
modification has no offset of theleads
neighboring cell onto Default/Recommen
a lower
higher
neighboring probability
probability.
cell, V100R001C00 Radio
impact on the a frequency in the ded
The parameter
equipment. of
Setreselection
Thresh
higher-prioritythe to a
this isparameter
modification has no neighboring
properly carrier
threshold
GERAN so cell
forthat
eventon
the Default/Recommen
V100R001C00 Radio
impact on the a
B1,frequency
selected
and Hys
frequency cell in
canthe
is the
group, ded
The parameter
equipment. lower-priority
provide
hysteresis
and a smallersignals
for eventthat
value
modification has no GERAN carrier Default/Recommen
meet
B1.
of thisthe quality
parameter V100R001C00 Radio
impact on the frequency group, ded
The parameter requirement
The
leads smaller of
the
to a higher
equipment. and a
modification has no of Ofn is,value
smaller
basic services.
value
probability. the Default/Recommen
None
of this parameter
harder event B1 is V100R001C00 Radio
impact on the ded
equipment. leads to a and
triggered, higher the
probability.
more slowly the
Not involved None V100R001C00 Radio Radio Planning
handover is
implemented. This
Not involved affects
None the user V100R001C00 Radio Radio Planning
experience. The
bigger the value of
Not involved None
Ofn is, the easier V100R001C00 Radio Radio Planning
event B1 is
Not involved triggered.
None This also V100R001C00 Radio Engineering Design
easily causes error
decision and
Not involved pingpong
None handover. V100R001C00 Radio Engineering Design
Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


A smaller value of
Not involved this
None parameter V100R001C00 Radio Radio Planning
leads to a lower
The parameter
probability of
modification has no Default/Recommen
handover to the V100R001C00 Radio
impact on the ded
The parameter neighboring cell. A
equipment.
modification has no larger value of this Default/Recommen
None
parameter leads to V100R001C00 Radio
impact on the ded
The parameter
equipment. a higher probability.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
equipment.
Default/Recommen
Not involved None V100R002C00 Radio
ded
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter A larger value of
equipment.
modification has no this parameter
None
leads to a higher V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment. probability of
modification has no starting Default/Recommen
None V100R001C00 Radio
impact on the measurements on ded
The parameter
equipment. neighboring cells on
modification has no
the neighboring E- V100R001C00 Radio Radio Planning
impact on the
The parameter UTRAN frequency
equipment.
modification has no and also a higher Default/Recommen
A smaller value of
None V100R001C00 Radio
impact on the probability of ded
The parameter this parameter
equipment. reselection to a
modification has no results in a greater Default/Recommen
neighboring
A smaller
None cell of
value on V100R001C00 Radio
impact on the impact of the UE ded
the
this neighboring
parameter
The parameter
equipment. mobility state on the
frequency.
results in a greater
modification has no cell reselection time
impact of the UE V100R001C00 Radio Engineering Design
impact on the within E-UTRAN,
The parameter
equipment. mobility state on
that is, results the
in a
modification has no cell reselection time
larger probability of V100R001C00 Radio Engineering Design
impact on the within E-UTRAN,A
cell reselection.
The parameter
equipment. that is, results in a
modification has no larger value leads
higher
None
to probability
a smaller impact. of V100R001C00 Radio Engineering Design
impact on the cell reselection. A
equipment. larger value leads
to a smaller impact.
With other
A larger value of
conditions
this parameter
unchanged, a larger
A larger value
With of
The parameter leadsother
value to this
of a lower
this parameter
conditions
modification has no probability of
parameter leads to Default/Recommen
leads
unchanged,to a lower V100R001C00 Radio
impact on the reselection
a lower toa alarger
probability ded
The parameter probability
value of thisof a
equipment. neighboring
of reselectioncell to on
a
modification has no neighboring
parameter inter-
leads to Default/Recommen
the neighboring
neighboring cell E-
on V100R001C00 Radio
impact on the frequency
a lower cell on
probability ded
The parameter UTRAN
the frequency.
higher-priority
equipment. the
of frequency to a
reselection
modification has no neighboring
meeting E- S
criteria Default/Recommen
neighboring
UTRAN cell on
frequency, V100R001C00 Radio
impact on the and becoming a ded
The parameter the
and lower-priority
a smaller value
equipment. suitable cell for
modification has no neighboring
of this parameterE- Default/Recommen
selection.
UTRAN A smaller
frequency, V100R001C00 Radio
impact on the leads to a higher ded
The parameter value
and a of this
smaller value
equipment. probability.
modification has no parameter
of this leads to
parameter Default/Recommen
None
a higher V100R001C00 Radio
impact on the leads to aprobability.
higher ded
The parameter
equipment. Set this parameter
probability.
modification has no properly so that the Default/Recommen
None this
Setting V100R001C00 Radio
impact on the selected cell ded
The parameter parameter to can
equipment. provide signals that
modification has no EventA3 improves Default/Recommen
meet
None the quality
the performance of V100R001C00 Radio
impact on the ded
The parameter requirement
handovers between of
equipment.
modification has no basic
intra-bandservices.
inter- Default/Recommen
None V100R001C00 Radio
impact on the frequency ded
The parameter
equipment. neighboring cells in
modification has no
terms of timeliness V100R003C00 Radio Engineering Design
impact on the
and interference.
equipment.
Setting this
Not involved None
parameter to V100R001C00 Radio Engineering Design
EventA4 reduces
Not involved the
None number of inter- V100R001C00 Radio Engineering Design
band inter-
frequency
Not involved handovers.
None V100R001C00 Radio Engineering Design

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


A smaller value of
Not involved this
None parameter V100R001C00 Radio Radio Planning
leads to a lower
The parameter
probability of
modification has no Default/Recommen
handover to the V100R001C00 Radio
impact on the ded
The parameter neighboring cell. A
equipment.
modification has no larger value of this Default/Recommen
None
parameter leads to V100R001C00 Radio
impact on the ded
The parameter
equipment. a higher probability.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Radio Planning
impact on the
equipment.
Default/Recommen
Not involved None V100R002C00 Radio
ded
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning

Not involved None V100R001C00 Radio Radio Planning


The parameter
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Radio Planning
impact on the
equipment.
Default/Recommen
Not involved None V100R002C00 Radio
ded
The parameter
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R001C00 Radio Radio Planning
Not involved None V100R001C00 Radio Radio Planning
The parameter
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no The
Noneentering V100R001C00 Radio Radio Planning
impact on the condition for event
The parameter
equipment. B1 is as follows: Mn
modification has no + Ofn - Hys > Default/Recommen
None V100R001C00 Radio
impact on the Thresh. Where Mn ded
The parameter
equipment. A
modification has no is larger value of
the measurement
this
None parameter
value of a V100R001C00 Radio Radio Planning
impact on the leads to a higher
The parameter
equipment. neighboring cell,
modification has no probability
Ofn is the of Default/Recommen
None
starting V100R001C00 Radio
impact on the frequency-specific ded
The parameter
equipment. measurements
offset the ofon
forvalue
A larger
modification has no neighboring
frequency ofcells
the on
this parameter V100R001C00 Radio Radio Planning
impact on the the UTRAN
neighboring cell,
The parameter leads to a lower
equipment. frequency
A largerisvalue
Thresh and of
the also
modification has no probability of a Default/Recommen
a higher
None
this probability
parameter
threshold for event V100R001C00 Radio
impact on the UTRAN FDD cell ded
The parameter of
B1,reselection
leads andto Hys
a istothe
lower a
equipment. meeting criteria S
modification has no neighboring
probability
hysteresis ofcell
a
for event on Default/Recommen
and becoming a V100R001C00 Radio
the
B1. UTRAN
UTRAN FDD
impact on the suitable cell cell ded
The parameter
equipment. frequency.
meeting
A smaller
With criteria
other value SA
of
selected by a UE.
modification has no and
Ofn becoming
leads
conditions to a a
lower Default/Recommen
smaller value of this V100R001C00 Radio
impact on the suitable
probability
unchanged, cellof a larger ded
The parameter parameter leads to
equipment. With
selected other
triggering
value by a UE.
event
of this B1.A
modification has no a higher probability. Default/Recommen
conditions
smaller
Thisthis value
mayparameter
parameter delay of
leadsthe this
to V100R001C00 Radio
impact on the Set ded
unchanged,
parameter
handover a larger
leads to
The parameter
equipment. a soandthataffect
lower probability
properly the
modification has no value
a
the
of higher
userof this
probability.
reselection to a Default/Recommen
selected cell can V100R001C00 Radio
impact on the parameter
Set
neighboring leads
this signals
experience. parameter
A
cell to
larger
on ded
provide that
The parameter
equipment. a lower
properly
value
the probability
so
of Ofn that
higher-priorityleads the
meet the quality
modification has no of
to reselection
selected
a higher
UTRAN cell ofcan
frequency, to a Default/Recommen
requirement V100R001C00 Radio
impact on the neighboring
provide
probability
and signals
ofcell on
that ded
basic services.value
a smaller
equipment. the
meet lower-priority
the
triggering
of this quality
event B1,
parameter
Not involved UTRAN
requirement
None to
which
leads frequency,
may of
cause
a higher V100R001C00 Radio Radio Planning
and
more decision value
basic a smaller
services.
probability.
of this and
errors parameter
ping-
Not involved None
leads to a higher
pong handovers. V100R001C00 Radio Radio Planning
probability.
Not involved None V100R001C00 Radio Radio Planning
The parameter
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
equipment.
The parameter
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Radio Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
NoneTPE algorithm,
The V100R001C00 Radio Engineering Design
impact on the
The parameter
equipment. if enabled,
modification has no increases the rate
None V100R001C00 Radio Engineering Design
impact on the of TCP services; if
The parameter
equipment. disabled, has no
modification has no impact
None on the V100R001C00 Radio Engineering Design
impact on the network. If the TPE
The parameter
equipment.
modification has no algorithm is
None
enabled, the source V100R001C01 Radio Engineering Design
impact on the
The parameter
equipment. eNodeB of a
modification has no handover will
V100R002C00 Radio Engineering Design
impact on the transmit the TCP
The parameter
equipment. packets stored in
modification has no the TPE buffer to
None V100R001C00 Radio Engineering Design
impact on the the target eNodeB
equipment. so that the server
does not need to
transmit the same
set of packets to
the target eNodeB,
increasing the rate
of TCP services.
The parameter
modification has no
None V100R001C01 Radio Engineering Design
impact
The on the
parameter
equipment.
modification takes
Default/Recommen
effect after the cell None V100R003C00 Radio
ded
is
Theautomatically
parameter
reset.
modification has no
None V100R003C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Radio
impact on the ded
equipment.
Not involved None V100R001C01 Radio Engineering Design
The parameter
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Radio
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Radio
impact on the ded
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
equipment.
The parameter
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Radio Engineering Design
impact on the
equipment.
Not involved None V100R003C00 Transport Transport Planning
The parameter
modification has no
None V100R003C00 Transport Transport Planning
impact on the
equipment.
Not involved None V100R002C00 Transport Transport Planning
The parameter
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
equipment.
The parameter
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Transport Transport Planning
impact on the
equipment.
Not involved None V100R002C00 Transport Transport Planning
The parameter
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
equipment.
Not involved None V100R002C00 Transport Not involved

Not involved None V100R002C00 Transport Not involved

Not involved None V100R002C00 Transport Not involved

Not involved None V100R002C00 Transport Not involved

Not involved None V100R002C00 Transport Not involved

Not involved None V100R002C00 Transport Not involved

Not involved None V100R002C00 Transport Not involved


The parameter
modification has no
None V100R001C01 Transport Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Engineering Design
impact on the
equipment.
The parameter
modification has no
None V100R002C00 Transport Engineering Design
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Engineering Design
impact on the
equipment.
Not involved None V100R001C01 Transport Transport Planning
The parameter
modification has no
None
If IPSec is applied V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. to a network where
modification has no FirstIPSecFlag is
V100R001C01 Transport Transport Planning
impact on the set to DISABLE, the
The parameter
equipment. eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None
If IPSec is applied V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. to a network where
modification has no SecIPSecFlag is
V100R001C01 Transport Transport Planning
impact on the set to DISABLE, the
The parameter
equipment. eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
Not involved None
If IPSec is applied V100R001C01 Transport Transport Planning
The parameter to a network where
modification has no IPSecFlag is set to
V100R001C01 Transport Transport Planning
impact on the DISABLE, the
The parameter
equipment. eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
Not involved None
If IPSec is applied V100R001C01 Transport Transport Planning
The parameter to a network where
modification has no LocIPSecFlag is set
V100R001C01 Transport Transport Planning
impact on the to DISABLE, the
The parameter
equipment. eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None
If IPSec is applied V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. to a network where
modification has no SecLocIPSecFlag
V100R001C01 Transport Transport Planning
impact on the is set to DISABLE,
The parameter
equipment. the eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
Not involved None V100R001C01 Transport Transport Planning
The parameter
modification has no
None
If IPSec is applied V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. to a network where
modification has no ServIP1IPSecFlag
V100R001C01 Transport Transport Planning
impact on the is set to DISABLE,
equipment. the eNodeB fails to
access the network.
The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None
If IPSec is applied V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. to a network where
modification has no ServIP2IPSecFlag
V100R001C01 Transport Transport Planning
impact on the is set to DISABLE,
The parameter
equipment. the eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None
If IPSec is applied V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. to a network where
modification has no ServIP3IPSecFlag
V100R001C01 Transport Transport Planning
impact on the is set to DISABLE,
The parameter
equipment. the eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None
If IPSec is applied V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. to a network where
modification has no ServIP4IPSecFlag
V100R001C01 Transport Transport Planning
impact on the is set to DISABLE,
The parameter
equipment. the eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
Not involved None
If IPSec is applied V100R001C01 Transport Transport Planning
The parameter to a network where
modification has no IPSecFlag is set to
V100R001C01 Transport Transport Planning
impact on the DISABLE, the
The parameter
equipment. eNodeB fails to
modification has no access
None the network. V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
equipment.
The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
Not involved None V100R001C01 Transport Transport Planning
The parameter
modification has no
Same as IPSec V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
Same as IPSec V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
The parameter
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
Not involved None V100R001C01 Transport Transport Planning
The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
Same as IPSec V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. If IPSec is
modification has no supported, the
V100R001C01 Transport Transport Planning
impact on the throughput is
The parameter
equipment. relatively low.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. If IPSec is
modification has no supported, the
V100R001C01 Transport Transport Planning
impact on the throughput is
The parameter
equipment. relatively low.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
equipment.
The parameter
modification has no
Same as IPSec V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
equipment.
The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R002C00 Transport Transport Planning
impact on the
equipment.
Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning


The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
equipment.
Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved


The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
equipment.
Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Not involved


Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning


Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R002C00 Transport Transport Planning

Not involved None V100R002C00 Transport Transport Planning


The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no A larger value of Default/Recommen
None V100R001C01 Transport
impact on the this parameter ded
The parameter
equipment. results in greater
modification has no A larger value of Default/Recommen
None
immunity to network V100R001C01 Transport
impact on the this parameter ded
The parameter delay, but it leads to
equipment. results
modification has no a longerintimegreater
None
immunity to
required to detect network V100R003C00 Transport Transport Planning
impact on the
The parameter delay, but it leads
disconnection andto
equipment.
modification has no a longer time
therefore a higher
None
required to ofdetect V100R001C01 Transport Transport Planning
impact on the probability long-
The parameter A smaller value
disconnection andof
equipment. time packet loss.
modification has no this parameter
therefore a higher Default/Recommen
A smaller
results in avalue
higher of V100R001C01 Transport
impact on the probability of long- ded
The parameter this parameter
probability of
equipment. time packet loss.
modification has no results
detecting in athe higher
worst Default/Recommen
A smaller
probability value
of of V100R001C01 Transport
impact on the link status, which ded
The parameter this parameter
detecting network
equipment. however is
modification has no results
status, in
but a itnot
higher
leads Default/Recommen
commonplace.
probability of A V100R001C01 Transport
impact on the to higher sensitivity ded
larger
detectingvalue of this
equipment. to packet network
parameter loss andin
results
Not involved status,
delay
None buttherefore
and it leads V100R001C00 Transport Transport Planning
a
to higher
higher probability
sensitivity
The parameter a
of higher probability
detecting theand
to
of packet
incorrect loss
modification has no best link status,
delay
None and therefore
decisions. V100R001C00 Transport Transport Planning
impact on the which however is
a higher probability
equipment. not commonplace.
of incorrect
Not involved None
decisions. V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning


The parameter
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
equipment.
Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning


Not involved None V100R001C00 Transport Transport Planning
The parameter
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
equipment.
Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Default/Recommen
Not involved None V100R001C01 Transport
ded
Default/Recommen
Not involved None V100R001C01 Transport
ded

Not involved None V100R001C01 Transport Equipment planning

Not involved None V100R001C01 Transport Transport Planning


The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
equipment.
Not involved None V100R001C01 Transport Transport Planning
The parameter
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
Default/Recommen
Not involved None V100R001C01 Transport
ded

Not involved None V100R001C01 Transport Not involved


Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Default/Recommen
Not involved None V100R001C01 Transport
ded
Default/Recommen
Not involved None V100R001C01 Transport
ded

Not involved None V100R001C01 Transport Equipment planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning


The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning

Default/Recommen
Not involved None V100R001C01 Transport
ded

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Default/Recommen
Not involved None V100R001C01 Transport
ded
Default/Recommen
Not involved None V100R001C01 Transport
ded

Not involved None V100R001C01 Transport Equipment planning

Not involved None V100R003C00 Transport Equipment planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved


Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R003C00 Transport Transport Planning

Not involved None V100R003C00 Transport Transport Planning


The parameter
modification has no
None V100R003C00 Transport Transport Planning
impact on the
equipment.
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded

Not involved None V100R001C00 Transport Equipment planning

Not involved None V100R003C00 Transport Equipment planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning


When the DHCP
relay switch is
Not involved None
enabled, the BS V100R001C00 Transport Transport Planning
The parameter automatically
modification has no forwards the DHCP
V100R001C00 Transport Transport Planning
impact on the requests from the
equipment. lower-level BS,
Not involved If this parameter
which
None increases the is V100R001C00 Transport Transport Planning
set
loadtoofDISABLE,
data a
The parameter
faulty remote
processing.
modification has no
maintenance V100R001C00 Transport Transport Planning
impact on the
The parameter channel cannot
equipment.
modification has no automatically Default/Recommen
None
A smaller
restore parameter
itself. V100R001C00 Transport
impact on the ded
The parameter
equipment. value indicates a
modification has no lower transmission
A smaller
This parameter
parameter Default/Recommen
V100R001C00 Transport
impact on the priority
value must
value of signaling
indicatesbe a ded
The parameter
equipment. data and affects
modification has no
lower transmission
different from thethe Default/Recommen
QoS.
priority of high-level
priorities of other V100R001C00 Transport
impact on the ded
The parameter OM service
services, so data
that
equipment. A smaller parameter
modification has no and affects
low-level OM the Default/Recommen
value
QoS. indicates a V100R001C00 Transport
impact on the service data (such ded
The parameter
equipment. lower
A transmission
smaller
as upload and parameter
modification has no priority
value
download of the
indicates
data) ais Default/Recommen
V100R001C01 Transport
impact on the Precision
lower Time
transmission
allocated the ded
The parameter
equipment. Protocol (PTP)
priority
minimalofbandwidth
the
modification has no packets and affects Default/Recommen
service
through packet
scheduling. V100R001C00 Transport
impact on the the QoS. ded
The parameter whose QoS Class
equipment.
modification has no Indicator (QCI) is 1 Default/Recommen
None
and affects the V100R002C00 Transport
impact on the ded
The parameter
equipment. QoS.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment. A smaller parameter
modification has no value Default/Recommen
None indicates a V100R002C00 Transport
impact on the lower transmission ded
The parameter
equipment. priority of the
modification has no Default/Recommen
service packet V100R001C00 Transport
impact on the ded
The parameter whose QoS Class
equipment.
modification has no Indicator (QCI) is 2 Default/Recommen
None
and affects the V100R002C00 Transport
impact on the ded
equipment. QoS.
The parameter
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment. A smaller parameter
modification has no value Default/Recommen
None indicates a V100R002C00 Transport
impact on the lower transmission ded
The parameter
equipment. priority of the
modification has no Default/Recommen
service packet V100R001C00 Transport
impact on the ded
The parameter whose QoS Class
equipment.
modification has no Indicator (QCI) is 3 Default/Recommen
None
and affects the V100R002C00 Transport
impact on the ded
The parameter
equipment. QoS.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment. A smaller parameter
modification has no value Default/Recommen
None indicates a V100R002C00 Transport
impact on the lower transmission ded
The parameter
equipment. priority of the
modification has no Default/Recommen
service packet V100R001C00 Transport
impact on the ded
The parameter whose QoS Class
equipment.
modification has no Indicator (QCI) is 4 Default/Recommen
None
and affects the V100R002C00 Transport
impact on the ded
The parameter
equipment. QoS.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment. A smaller parameter
modification has no value Default/Recommen
None indicates a V100R002C00 Transport
impact on the lower transmission ded
The parameter
equipment. priority of the
modification has no Default/Recommen
service packet V100R001C00 Transport
impact on the ded
The parameter whose QoS Class
equipment.
modification has no Indicator (QCI) is 5 Default/Recommen
None
and affects the V100R002C00 Transport
impact on the ded
The parameter
equipment. QoS.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment. A smaller parameter
modification has no value Default/Recommen
None indicates a V100R002C00 Transport
impact on the lower transmission ded
The parameter
equipment. priority of the
modification has no Default/Recommen
service packet V100R001C00 Transport
impact on the ded
The parameter whose QoS Class
equipment.
modification has no Indicator (QCI) is 6 Default/Recommen
None
and affects the V100R002C00 Transport
impact on the ded
The parameter
equipment. QoS.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment. A smaller parameter
modification has no value Default/Recommen
None indicates a V100R002C00 Transport
impact on the lower transmission ded
The parameter
equipment. priority of the
modification has no Default/Recommen
service packet V100R001C00 Transport
impact on the ded
The parameter whose QoS Class
equipment.
modification has no Indicator (QCI) is 7 Default/Recommen
Noneaffects the
and V100R002C00 Transport
impact on the ded
The parameter
equipment. QoS.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment. A smaller parameter
modification has no value Default/Recommen
None indicates a V100R002C00 Transport
impact on the lower transmission ded
The parameter
equipment. priority of the
modification has no Default/Recommen
service packet V100R001C00 Transport
impact on the ded
whose QoS Class
equipment.
Indicator (QCI) is 8
and affects the
QoS.
The parameter
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment. A smaller parameter
modification has no value Default/Recommen
None indicates a V100R002C00 Transport
impact on the lower transmission ded
The parameter
equipment. priority of the
modification has no Default/Recommen
service packet V100R001C00 Transport
impact on the ded
The parameter whose QoS Class
equipment.
modification has no Indicator (QCI) is 9 Default/Recommen
None
and affects the V100R002C00 Transport
impact on the ded
The parameter
equipment. QoS.
modification has no If this parameter is Default/Recommen
None
set to OFF, the V100R002C00 Transport
impact on the ded
The parameter
equipment. throughput on the
modification has no If
airthis parameter
interface will is Default/Recommen
None
set to OFF, the V100R002C00 Transport
impact on the drop due to ded
The parameter throughput
equipment. overload of on thethe
modification has no air interface will
central processing V100R003C00 Transport Engineering Design
impact on the drop due towhen
The parameter unit (CPU)
equipment. overload of the
modification has no the DL traffic on the
central processing
S1 interface V100R003C00 Transport Engineering Design
impact on the
unit
exceeds(CPU)thewhen
equipment.
the DL
capabilitytraffic on the
of the Default/Recommen
Not involved None
S1 interface V100R001C00 Transport
LBBP. ded
exceeds the
capability of the Default/Recommen
Not involved None V100R001C00 Transport
LBBP. ded

Not involved None V100R001C00 Transport Equipment planning

Not involved None V100R001C00 Transport Transport Planning


The parameter
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
equipment.
Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R003C00 Transport Equipment planning


The parameter
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
equipment.
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded

Not involved None V100R001C00 Transport Equipment planning

Not involved None V100R001C00 Transport Equipment planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved


Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded

Not involved None


An excessive large V100R001C00 Transport Equipment planning
parameter value
leads to packet loss
Not involved None V100R003C00 Transport Equipment planning
or excessively-
fragmented data
Not involved packets
None on the V100R001C00 Transport Transport Planning
The parameter transport network,
modification has noresulting in a long
None and
delay V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment. deteriorated
modification has noperformance. An Default/Recommen
V100R001C00 Transport
impact on the excessive small ded
The parameter
equipment. parameter value
modification has noleads Default/Recommen
None to reduced V100R001C00 Transport
impact on the available payloads ded
The parameter
equipment.
modification has nofor transmission, Default/Recommen
None
resulting in V100R001C00 Transport
impact on the ded
The parameter
equipment. decreased transport
modification has nobandwidth Default/Recommen
None V100R001C00 Transport
impact on the efficiency and ded
The parameter
equipment. deteriorated
modification has noperformance. Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
equipment.
Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved


Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Default/Recommen
Not involved None V100R001C01 Transport
ded
Default/Recommen
Not involved None V100R001C01 Transport
ded

Not involved None V100R001C01 Transport Equipment planning

Default/Recommen
Not involved None V100R001C01 Transport
ded
The parameter
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C01 Transport
impact on the ded
equipment.
An excessive large
parameter value
leads to packet loss
or excessively-
fragmented data
packets on the
transport network,
resulting in a long
Not involved None
delay and V100R003C00 Transport Equipment planning
The parameter deteriorated
modification has no performance. An Default/Recommen
V100R001C01 Transport
impact on the excessive small ded
equipment. parameter value
Not involved leads
None to decreased V100R001C01 Transport Not involved
available payloads
for transmission,
Not involved None
resulting in V100R001C01 Transport Not involved
ineffective use of
the transport
Not involved None V100R001C01 Transport Not involved
network bandwidth
and deteriorated
Not involved performance.
None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Default/Recommen
Not involved None V100R001C01 Transport
ded
Default/Recommen
Not involved None V100R001C01 Transport
ded

Not involved None V100R001C01 Transport Equipment planning

Not involved None V100R001C01 Transport Transport Planning


Not involved None V100R001C01 Transport Transport Planning

Default/Recommen
Not involved None V100R001C01 Transport
ded

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R003C00 Transport Equipment planning

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R002C00 Transport Transport Planning


The parameter
modification has no
None V100R003C00 Transport Transport Planning
impact on the
equipment.
Not involved None V100R003C00 Transport Transport Planning
The parameter
modification has no
None V100R003C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R003C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Modifications to this
None V100R003C00 Transport Transport Planning
impact on the parameter affect the
The parameter
equipment. admission of new
modification has no Modifications to this
services and the V100R003C00 Transport Engineering Design
impact on the parameter affect the
The parameter quality of admitted
equipment. admission of newon
modification has no services carried
services and the
resource groups. V100R003C00 Transport Engineering Design
impact on the
The parameter quality of admitted
equipment.
modification has no services carried on
None
resource groups. V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
equipment.
The parameter
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no
None V100R003C00 Transport Not involved
impact on the
equipment.
Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R001C00 Transport Transport Planning


The parameter
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no
None V100R003C00 Transport Transport Planning
impact on the
equipment.
Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R001C00 Transport Transport Planning


The parameter
modification has no
None V100R001C00 Transport Transport Planning
impact on the
equipment.
The parameter
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Transport
impact on the ded
equipment.
Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded

Not involved None V100R001C00 Transport Equipment planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning

Not involved None V100R003C00 Transport Transport Planning

Not involved None V100R003C00 Transport Transport Planning

Not involved None V100R003C00 Transport Transport Planning

Not involved None V100R003C00 Transport Transport Planning

Not involved None V100R001C00 Transport Transport Planning


The parameter
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no
None V100R001C00 Transport Equipment planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
equipment.
The parameter
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no
None V100R001C00 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment.
modification has no
None V100R001C01 Transport Transport Planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R001C00 Transport
impact on the ded
equipment.
Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved

Not involved None V100R001C00 Transport Not involved


The parameter
modification has no
None V100R003C00 Transport Equipment planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R002C00 Transport
impact on the ded
The parameter
equipment.
modification has no
None V100R003C00 Transport Equipment planning
impact on the
The parameter
equipment.
modification has no Default/Recommen
None V100R003C00 Transport
impact on the ded
equipment.
Not involved None V100R002C00 Transport Transport Planning

Not involved None V100R002C00 Transport Transport Planning

Not involved None V100R002C00 Transport Transport Planning


Not involved None V100R002C00 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Transport Planning

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Not involved None V100R001C01 Transport Not involved

Default/Recommen
Not involved None V100R003C00 Transport
ded
Default/Recommen
Not involved None V100R003C00 Transport
ded

Not involved None V100R003C00 Transport Transport Planning

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Not involved None V100R003C00 Transport Not involved

Default/Recommen
Not involved None V100R001C00 Transport
ded
Default/Recommen
Not involved None V100R001C00 Transport
ded

Not involved None V100R001C00 Transport Equipment planning


Not involved None V100R003C00 Transport Equipment planning

Not involved None V100R001C00 Transport Transpor

You might also like