You are on page 1of 33

ELECTRIC PRODUCT CATALOGUE

  ! " # $ % & '


www.cetelec.com.cn
BRIEF
Our company has successfully
SHANGHAI CET ELECTRIC CO. developed and manufacturing
LTD. is one of the leading and numerous electric products, INTRODUCTION
the most reliable manufacturers such as circuit breaker, AC
sold in more than 70 Countries
and exporters for low voltage and contactor, meter, relay, control
and regions in the world.
high voltage electric products in units as well as lightings items
Moreover, Our company has
China. and so on, in high quality.
always paid special attention to
SHANGHAI CET ELECTRIC CO.
ISO9001:2000
protect the benefit of clients' so
LTD. possesses full line of high-
Certification Companies of that both the clients and we are
tech production equipment and
Quality Systems able to gain the maximum benefit
great strength of technology
from the relations between.
support besides advanced
We warmly look forward to
designation forces powered by
establishing, reinforcing and
the first class engineering teams
expanding a long term fruitful
with super industrial computer
collaboration relationship with the
systems. Thus, our products are
reliable clients all over the world.
novel in design, excellent in
Conformity to the LV standard Let's get busy and pull together
workmanship and top reliable in
to create a better future!
quality. A lot of our products
have obtained " SEMKO ", " CB
", " CE ", " IRAM " and other
international quality approvals.
The products are now being well

Turkish standards Association


Turkey

TUV Rheinland/
Berlin-Brandenburg
SHCET GROUP
Shanghai CET Electric Co.,Ltd.

QUALIFICATION
CERTIFICATE COLLECTION
Through meticulosity and
repeatedly hammered,we have
founded the remarkable quality.
O u r p r o d u c t s h ave p a s s e d
through the domestic and foreign
authentications including cULus,
CCC,CB,CE,and so on,Besides,
MCB and AC Contactor have got
the patent for designed-
appearance.
Weve got the certificate of
ISO9001 IntQuality System,
etc
SHCET GROUP
Shanghai CET Electric Co.,Ltd.

D-01/02
D-03/05
CJX2-DN AC Contactor
CJX2-D(LC1-D) AC Contactor
AC
D
D-06 CJX1-F(LC1-F) AC Contactor
Contactor
D-07 CJX1-Y Energy Saving Contactor
D-08 CJX2-D/F Mechanical Interlocking Contactor
D-09 CJX1-K AC Contactor
D-09 LP1-D DC Operated AC Contactor
D-10 3TF AC Contactor
D-11 3TB AC Contactor
D-11 3TD Mechanical Interlocking Contactor
D-12 3TH Auxiliary Contactor
D-12 LX1 Bobbin of AC Contactor
D-13 LA Auxiliary Contact Block
D-13 LA2-D Delay Timer
D-14 New Mould Contactor (KT6022/KT6023)
D-15 A AC Contactor
D-15 S-N AC Contactor
D-16 GMC AC Contactor
D-16 Auxiliary For AC Contactor GMC
D-17/18 LR2-D Thermal Overload Relay
D-18 LR2-F Electronic Thermal Overload Relay
D-19 LRD Thermal Overload Relay
D-20 LR1-D Thermal Overload Relay
D-21 3UA Thermal Overload Relay
D-22 GTH Thermal Overload Relay
D-23 JR28 Thermal Overload Relay
D-24 LE1-N Magnetic Starter
D-25 LE1-D Magnetic Starter
D-26 LC3-D Star-delta Reduced Voltage Starter
D-27 AD Magnetic Starter and Star-delta Starter
D-27 SRCa Magnetic Starter
CJX2-DN AC Contactor

Application
CJX2-DN series AC contactors are suitable for frequency 50/60Hz,rated insulation volt-
age up to 1000V,rated operation current 9~150A under AC-3 duty.It is mainly used for
making and breaking electric circuits at a long distance & for frequent starting, stopping
& controlling AC Motors.It is used in combination with thermal relay to compose a mag-
netic motor starter. The products comply with IEC60947-4.

Specifications
CJX2-09N
Rated current
le max AC-3 (Ue  440V) 9A 12A 18A 25A 32A
le AC-1 (0  60C) 25A 32A 40A 50A
Number of poles 3 3 4 3 3 4 3
220/240V 2.2KW 3KW 4KW 5.5KW 7.5KW
Rated 380/400V 4KW 5.5KW 7.5KW 11KW 15KW
operational 415/440V 4KW 5.5KW 9KW 11KW 15KW
power in AC-3 500V 5.5KW 7.5KW 10KW 15KW 18.5KW
660/690V 5.5KW 7.5KW 10KW 15KW 18.5KW
1000V
Auxiliary contacts range comprising up to 4 N/C or N/O instantaneous, up
to 1N/O+1N/C time delay and up to 2 N/O or N/C
protected contacts and 2 screen continuity terminals
Compatible
manual or auto Class 10 A 0.1010A 0.1013A 0.1018A 0.1032A 0.1038A
thermal overload
relays Class 20 2.510A 2.513A 2.518A 2.532A
CJX2-25N
Suppressor Varistor
modules
(d.c.and low Diode
consumption
contactors have
built-in suppres- RC circuit
sion limiting diode
as standard) Bidirectional peak
Relay
Interfaces Relay+override function
Solid state
~ or
--- 3P CJX2-09N CJX2-12N CJX2-18N CJX2-25N CJX2-32N
Contactor type
~4-P CJX2-12N CJX2-25N
references
4P
--- CJX2-12N CJX2-25N
~ 3P CJX2-09N CJX2-12N CJX2-18N CJX2-25N CJX2-32N
Reversing
3P
--- CJX2-09N CJX2-12N CJX2-18N CJX2-25N CJX2-32N
contactor
~ 4P CJX2-12N CJX2-25N
type references

--- 4P CJX2-12N CJX2-25N

CJX2-50N

D-01 SHCET
AC
Contactor

Standard Control Circuit Voltages


Volts 24 42 48 110 220 230 240 380 400 415 440 500 660
50Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5
60Hz B6 D6 E6 F6 M6 U6 Q6 R6
50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

CJX2-80N

38A 40A 50A 65A 80A 95A 115A 150A

Contactors
60A 80A 125A 200A
3 4 3 3 4 3 4 3 3 4 3
9KW 11KW 15KW 18.5KW 22KW 25KW 30KW 40KW
18.5KW 18.5KW 22KW 30KW 37KW 45KW 55KW 75KW
18.5KW 22KW 25/30KW 37KW 45KW 45KW 59KW 80KW
18.5KW 22KW 30KW 37KW 55KW 55KW 75KW 90KW
18.5KW 30KW 33KW 37KW 45KW 45KW 80KW 100KW
22KW 30KW 37KW 45KW 45KW 75KW 90KW

range comprising up to 4 N/C or N/O instantaneous, up to 1N/O+1N/C time delay and up


to 2 N/O or N/C protected contacts and 2 screen continuity terminals

0.1038A 1750A 1770A 1780A 17104A 17104A 60150A 60150A


1740A 1765A 1770A 1780A 60150A 60150A
CJX2-115N







CJX2-38N CJX2-40N CJX2-50N CJX2-65N CJX2-80N CJX2-95N CJX2-115N CJX2-150N
CJX2-40N CJX2-65N CJX2-80N CJX2-115N
CJX2-40N CJX2-65N CJX2-80N CJX2-115N
CJX2-38N CJX2-40N CJX2-50N CJX2-65N CJX2-80N CJX2-95N CJX2-115N CJX2-150N
CJX2-38N
CJX2-40N CJX2-65N CJX2-80N CJX2-115N

CJX2-150N

SHCET D-02
CJX2-D(LC1-D) AC Contactor

Application
CJX2-D series AC Contactor is suitable for using in the circuits up to the rated voltage
660V AC 50Hz or 60Hz, rated current up to 620A, for making, breaking, frequently
starting & controlling the AC motor. Combined with the auxiliary contact block, timer
delay & machine-interlocking device etc, it becomes the delay contactor, mechanical
interlocking contactor, star-delta starter. With the thermal relay, it is combined into the
electromagnetic starter. The products comply with IEC60947-4.

Specifications
CJX2-D09
Model D09 D12 D18 D25 D32 D40 D50 D65
Rated working AC3 9 12 18 25 32 40 50 65
current (A) AC4 3.5 5 7.7 8.5 12 18.5 24 28
AC3 capacity 220/230V 2.2 3 4 5.5 7.5 11 15 18.5
of phase 3 380/400V 4 5.5 7.5 11 15 18.5 22 30
squirrel-cage 415V 4 5.5 9 11 15 22 25 37
motor AC3 500V 5.5 7.5 10 15 18.5 22 30 37
(KW) 660/690V 5.5 7.5 10 15 18.5 30 33 37
Rated heat current (A) 20 20 32 40 50 60 80 80
AC3 x 104 100 100 100 100 80 80 60 60
Electrical life
AC4 x 104 20 20 20 20 20 15 15 15
Mechanical life x 104 1000 1000 1000 1000 800 800 800 800
CJX2-D25 3P+NO
Number of the contacts 3P+NC+NO
3P+NC

Dimension & Mounting Size


For CJX2-D09~95 contactors:
Type A B C D E a b
CJX2-D09~12 47 76 82 113 133 34/35 50/60 4.5
CJX2-D18 47 76 87 118 138 34/35 50/60 4.5
CJX2-D25 57 86 95 126 146 40 48 4.5
CJX2-D32 57 86 100 131 151 40 48 4.5
CJX2-D40~65 77 129 116 145 165 40 100/110 6.5
CJX2-D80~95 87 129 127 175 195 40 100/110 6.5
CJX2-D50

CJX2-D95

D-03 SHCET
AC
Contactor

Standard Control Circuit Voltages


Volts 24 42 48 110 220 230 240 380 400 415 440 500660
50Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5
60Hz B6 D6 E6 F6 M6 U6 Q6 R6
50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

CJX2-D115
D80 D95 D115 D150 D170 D205 D245 D300 D410 D475 D620
80 95 115 150 170 205 245 300 410 475 620

Contactors
37 44 52 60 75 85 105 117 138 147 180
22 25 30 40 55 63 75 100 110 147 200
37 45 55 75 90 110 132 160 220 265 335
45 45 59 80 100 110 132 180 220 280 375
55 55 75 90 110 129 160 200 250 355 400
45 55 80 100 110 129 160 220 280 355 450
125 125 200 250 250 275 315 400 500 700 1000
60 60 200 60 60 50 50 50 30 30 20
10 10 15 15 15 15 15 15 8 8 5
600 600 300 300 300 300 300 300 100 100 100
CJX2-D205
3P+NC+NO

For TSC1-D115~620 contactors:


Type A B C b1 P Q S Q1 M N L Ga Ha
CJX2-D115 158 120 132 158 35 60 17 25 134 96.2 75 M6
CJX2-D150 158 120 132 158 35 60 17 25 134 96.2 75 M6
CJX2-D170 158 120 132 158 35 60 17 25 134 96.2 75 M6
CJX2-D205 168.5 174 181 137 40 69 20 59.4 154 127 113.5 M8 80 120-106
CJX2-D245 168.5 197 181 137 48 69 25 51.5 172 127 113.5 M10 80 120-106
CJX2-D300 213 206 219 145 48 91 25 74 181 158 145 M10 80 120-106 CJX2-D300
CJX2-D410 213 206 219 209 48 91 25 74 181 158 145 M10 80 120-106
CJX2-D475 233 238 232 209 55 108 30 77 208 172 146 M10 80 180
CJX2-D620 309 304 255 280 80 140 40 89 264 202 155 M12 80 180

CJX2-D620

SHCET D-04
CJX2-D(LC1-D) AC Contactor

Application
CJX2-D series AC Contactor is suitable for using in the circuits up to the rated voltage
660V AC 50Hz or 60Hz, rated current up to 95A, for making, breaking, frequently start-
ing & controlling the AC motor. Combined with the auxiliary contact block, timer delay
& machine-interlocking device etc, it becomes the delay contactor, mechanical inter-
locking contactor, star-delta starter. With the thermal relay, it is combined into the elec-
tromagnetic starter. The products comply with IEC60947-4.

CJX2-D18
Specifications

Type CJX2-D09 CJX2-D12 CJX2-D18 CJX2-D25 CJX2-D32


Rated working AC3 9 12 18 25 32
current (A) AC4 3.5 5 7.7 8.5 12
220/230V 2.2 3 4 5.5 7.5
380/400V 4 5.5 7.5 11 15
AC3 capacity of phase
415V 4 5.5 9 11 15
3 squirrel-cage motor
500V 5.5 7.5 10 15 18.5
AC3(KW)
660/690V 5.5 7.5 10 15 18.5
Rated heat current (A) 20 20 32 40 50
AC3 x 104 100 100 100 100 80
Electrical life
AC4 x 104 20 20 20 20 20
CJX2-D32 4
Mechanical life x 10 1000 1000 1000 1000 800
3P+NO
Number of the contacts
3P+NC

Type CJX2-D40 CJX2-D50 CJX2-D65 CJX2-D80 CJX2-D95


Rated working AC3 40 50 65 80 95
current (A) AC4 18.5 24 28 37 44
220/230V 11 15 18.5 22 25
380/400V 18.5 22 30 37 45
AC3 capacity of phase
415V 22 25 37 45 45
3 squirrel-cage motor
500V 22 30 37 55 55
AC3(KW)
660/690V 30 33 37 45 55
Rated heat current (A) 60 80 80 125 125
CJX2-D40
AC3 x 104 80 60 60 60 60
Electrical life
AC4 x 104 15 15 15 10 10
4
Mechanical life x 10 800 800 800 600 600
Number of the contacts 3P+NC+NO

Standard Control Circuit Voltages


Volts 24 42 48 110 220 230 240 380 400 415 440 500 660
50Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5
60Hz B6 D6 E6 F6 M6 U6 Q6 R6
CJX2-D95 50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

D-05 SHCET
AC
Contactor
CJX1-F(LC1-F) AC Contactor

Application
CJX1-F series AC Contactor is applicable to the circuits up to the rated voltage 1000V
AC 50Hz or 60Hz, rated current from 115A to 800A, for long distance breaking circuit
and frequently starting or controlling the motor. It also can be used for the control of
distribution circuits of rated current from 200A to 1600A.

Specifications

CJX1- CJX1- CJX1- CJX1- CJX1- CJX1-


Type
CJX1-F115 F115 F150 F185 F225 F265 F330
Rated operation AC-3 115 150 185 225 265 330

Contactors
current(A) AC-1 200 250 275 315 350 400
220/230V 30 40 55 63 75 100
380/400V 55 75 90 110 132 160
Standard power 415V 59 80 100 110 140 180
ratings of 440V 59 80 100 110 140 200
3-phase motors 500V 75 90 110 129 160 200
AC-3 (KW) 660/690V 80 100 110 129 160 200
1000V 65 65 100 100 147 160

CJX1-F150 CJX1- CJX1- CJX1- CJX1- CJX1-


Type
F400 F500 F630 F780 F800
Rated operation AC-3 400 500 630 780 800
current(A) AC-1 500 700 1000 1500 1500
220/230V 110 147 200 220 220
380/400V 200 250 335 400 400
Standard power 415V 200 280 375 425 420
ratings of 440V 250 295 400 425 420
3-phase motors 500V 257 355 400 450 430
AC-3 (KW) 660/690V 280 335 450 475 470
1000V 185 335 450 450 450
CJX1-F630
Both 3 pole and 4 pole are available.

CJX1-F780 CJX1-F1154 CJX1-F5004

SHCET D-06
CJX1-Y Energy Saving Contactor
Application
CJX1-Y Energy Saving AC contactor is applicable in the circuits up to the rated voltage
1000V, AC 50Hz or 60Hz, rated current up to 1000A, for long distance switching on and
breaking circuit and frequently starting or control AC motor. It can form electromagnetic
starter with thermal overload relay or electronic protector. It can also protect overload
or open-phase current, and form reversing interlock conversion contactor, power-distri-
bution conversion contactor and star-delta starter.
Specifications
Rated operation Rated thermal Three phase electromotor
Suitable
voltage 380V current rated power
Model thermal
CJX1-Y150 AC3 AC1 AC3 380V 50Hz
relay
le/A lth/A kW Hp-ch
CJX1-Y115 115 200 55 75 JR28-200
CJX1-Y150 150 250 75 100 JR28-200
CJX1-Y185 185 275 90 125 JR28-200
CJX1-Y225 225 315 110 150 JR28-630
CJX1-Y265 265 350 132 180 JR28-630
CJX1-Y330 330 400 160 220 JR28-630
CJX1-Y400 400 500 200 280 JR28-630
CJX1-Y500 500 700 250 335 JR28-630
CJX1-Y630 630 1000 335 450 JR28-630
Advantages
a. Power saving: 5% of traditional power consuming.
b. Long life: short arc duration, little contact ablation, contact does not quiver when
voltage fluctuates.
CJX1-Y630 c. Reliable: coil does not burn.
d. No noise.
e. Coil control, no temperature rising.
f. Not influenced by network voltage fluctuation.
Energy conservation contrast
Configration Energy saving comparison between energy saving AC contactor and traditional elec-
tromagnetic AC contactor under same condition.
CJX1-Y Energy Saving contactor Traditional contactor
Rated Annual electricity Rated Annual electricity
current V VA mA V VA
consumption current consumption
115 220 Retain Power 100 333 220 73.26 641.76
185 220 when consumption 160 461 220 101.42 888.44
265 220 power 250 686 220 150.92 1322.06
occurs only in
400 220 breaking 400 854 220 185.90 1628.48
starting
630 220 off 630 1511 220 332.42 2911.99

Operation Principle

SB1 is control button for pull-in.


SB2 is control button for releasing.

D-07 SHCET
AC
Contactor
CJX2-D/F Mechanical Interlocking Contactor

Specifications
Rated current Controlled power(KW)
Type
AC-3(A) 220V 380V 415V 440V 660V
CJX2-D09 9 2.2 4 4 4 5.5
CJX2-D12 12 5.5 5.5 5.5 5.5 7.5
CJX2-D18 18 7.5 7.5 9 9 10
CJX2-D25 25 5.5 11 11 11 15
CJX2-D32 32 7.5 15 15 15 18.5
CJX2-D40 40 18.5 18.5 22 22 30
CJX2-D09
CJX2-D50 50 15 22 25 30 33
CJX2-D63 63 18.5 30 37 37 37

Contactors
CJX2-D80 80 22 37 45 45 45
CJX2-D95 95 22 45 45 45 41
CJX2-D115 115 30 55 59 59 80
CJX2-D150 150 40 75 80 80 100
CJX2-D170 170 55 90 100 100 110
CJX2-D205 205 63 110 110 110 129
CJX2-D245 245 75 132 132 132 160
CJX2-D300 300 100 160 200 200 220
CJX2-D410 410 110 220 250 250 280
CJX2-D475 475 147 265 280 280 355
CJX2-D620 620 200 335 400 400 450

Number of Rated Current Rated Current Controlled power(KW)


Type
Poles AC-3(A) In/A 220V 380V
CJX2-F115 3P 115 250 200 55
CJX2-D50 CJX2-F1154 4P 115 250 200 55
CJX2-F150 3P 150 355 250 75
CJX2-F1504 4P 150 355 250 75
CJX2-F185 3P 185 425 275 90
CJX2-F1854 4P 185 425 275 90
CJX2-F225 3P 225 500 315 110
CJX2-F2254 4P 225 500 315 110
CJX2-F265 3P 265 630 350 132
CJX2-F2654 4P 265 630 350 132
CJX2-F330 3P 330 800 400 160
CJX2-F3304 4P 330 800 400 160
CJX2-F400 3P 400 800 500 200
CJX2-F4004 4P 400 800 500 200
CJX2-F500 3P 500 1000 700 250
CJX2-F5004 4P 500 1000 700 250
CJX2-F630 3P 630 1250 1000 335
CJX2-F6304 4P 630 1250 1000 335
CJX2-F115 CJX2-F800 3P 800 1250 1000 400

SHCET D-08
CJX1-K AC Contactor

Application
CJX1-K series AC contactor is suitable for use in the circuit for frequent starting, con-
trolling the AC motor. The addition of auxiliary contact group to the contactor, combined
with the proper thermal relay, can act to protect the circuit bound to overload.

Specifications

Type CJX1-K06 CJX1-K09 CJX1-K12


Rated current at AC3 (A) 6 9 12
Rated working current (Ie)A 5 7.5 10
Conventional thermal current(Ith)A 16 20 20
CJX1-K06, 09, 12 220V 1.5 2.2 3
AC-3 Use Group
380/415V 2.2 4 5
Control Power
440/500V 3 4 5
KW
660V 3 4 5
Rated working voltage (Ue)V 380 660
Rated insulation voltage (Ui)V 690
AC-3 Electrical life (times) 0.5 x 106
(6Ie Ie) Operation frequency h-1 1200
AC-4 Electrical life (times) 10 x 104
(6Ie Ie) Operation frequency h-1 300
Mechanical life 3 x 106
Conventional thermal current 6A
Auxiliary
Electrical life AC-15(360VA)
contact 0.5 x 106
(times) DC-13(33W)

CJX1-K06, 09, 12

LP1-D DC Operated AC Contactor

Specifications

Rated Rated
Rated Rated Electri- Con-
working insula-
heat working Controlled Power(KW) cal life tacts
Type current A tion
current voltage (AC-3) Num-
IeA voltage
Ith(A) Ue (A) 104 ber
(AC-3) Ui A 220V 380V 415V 440V 660V
LP1-D09 9 20 2.2 4 4 4 5.5
LP1-D12 12 20 3 5.5 5.5 5.5 7.5
LP1-D18 18 32 4 7.5 9 9 9 3P+NO
380V
LP1-D25 25 40 5.5 11 11 11 15 3P+NC
LP1-D32 32 50 7.5 15 15 15 18.5
660V 660V
LP1-D40 40 60 11 18.5 22 22 30
LP1-D50 50 80 15 22 25 30 33 3P+NO
660V
LP1-D09 LP1-D65 65 80 18.5 30 37 37 37 +NC
LP1-D80 80 125 22 37 45 45 45
LP1-D95 95 125 25 45 45 45 45

D-09 SHCET
AC
Contactor
3TF AC Contactor

Application
3TF series AC Contactors are suitable in electrical system with AC 50/60Hz, rated
operational voltage up to 660V, In AC-3 usage, rated operational voltage up to 380V,
rated operational current up to 630A to make or break remote motors or system. They
can form electromagnetic starters with suitable thermal overload relays 3UA series to
protect system and motors against overload or phase-failure. They are made according
to IEC60947-4.
The contactor is a straight motion mechanism having double-breaking contacts. The
auxiliary contacts are arranged 2NO, 2NC at most. It is employed the flexible locking
3TF 40 connection between the contact support and core. There are no arc-isolated panel in
the le  22A contactors. In the In  32A contactors, there are moulded arc-chute with
arc-isolated panel. Because all contacts are made of high non-fusibility and against

Contactors
corrosion silver alloy. All series products can be mounted by screws, le32A contactor
also by installation rail.

Specifications

Controllable power of motor


Rated Rated operation Type of
(KW)
Type thermal current (A) auxiliary
AC-3 AC-4
current (A) contact
380V 660V 380V 660V 380V 660V
3TF30 20 9 3.33 4 5.5 1.4 2.4
3TF31 20 12 4.33 5.5 7.5 1.9 3.3
NO
3TF32 30 18 7.77 7.5 11 3.5 6
NC
3TF33 30 22 8.5 11 11 4 6.6
1NO+1NC
3TF34 45 32 15.6 15 23 7.5 13
2NO+2NC
3TF35 45 38 18.5 18.5 23 9 15.5
3TF 50 3TF40 20 9 3.3 4 5.5 1.4 2.4
3TF41 20 12 4.3 5.5 7.5 1.9 3.3
3TF42 30 16 7.7 7.5 11 3.5 6
3TF43 30 22 8.5 11 11 4 6.6
3TF44 45 32 15.6 15 23 7.5 13
3TF45 45 38 18.5 18.5 23 9 15.5
3TF46 70 45 24 22 39 12 20.8
3TF47 70 63 28 30 55 14 24.3
3TF48 90 75 34 37 67 17 29.5
3TF49 90 85 42 45 67 21 36 2NC+2NO
3TF50 150 110 54 55 100 27 46.9 4NC+4NO
3TF51 150 140 68 75 100 35 60
3TF52 180 170 75 90 156 38 66
3TF53 220 205 96 110 156 50 86
3TF54 300 250 110 132 235 58 100
3TF55 300 300 125 160 235 66 114
3TF56 400 400 150 200 375 81 140
3TF57 550 475 150 250 375 81 140
3TF 56 3TF68 630 630 600 335 560 160 278

SHCET D-10
3TB AC Contactor

Application
The contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz
or 60Hz, rated current 630A, for making and breaking, and for frequent starting and
controlling the motor. After combined with the mechanical interlocking device, it be-
comes 3TD Series convertible contactor for controlling, starting, breaking and revers-
ing of the motor. The products comply with IEC60947-4.

Specifications
Rated The power of controlled
Rated Rated operat- Type of
3TB 44 operating motor (KW)
Type thermal ing current at auxiliary
current at
current (A) AC 3 380V (A) contact
660V (A) 380V 660V
3TB40 20 9 3.3 4 5.5 1NO
3TB41 20 12 4.3 5.5 7.5 1NC
3TB42 30 16 7.7 7.5 11 1NO+1NC
3TB43 30 22 8.5 11 11 2NO+2NC
3TB44 45 32 12 15 23 2NC+2NO

3TD Mechanical Interlocking Contactor

Application
The contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz
or 60Hz, current 300A, for convertible controlling the motor. Its mechanical interlocking
device ensures contact changeover of the two convertible contactors.

Specifications
3TD 41 Controllable power of motor
Rated operation
Rated thermal (KW)
Type current (A)
current (A) AC 3 AC 4
380V 660V 380V 660V 380V 660V
3TD40 20 9 3.3 4 5.5 1.4 2.4
3TD41 20 12 4.3 5.5 7.5 1.9 3.3
3TD42 30 16 7.7 7.5 11 3.5 6
3TD43 30 22 8.5 11 11 4 6.6
3TD44 45 32 15.6 15 23 7.5 13
3TD45 45 38 18.5 18.5 23 9 15.5
3TD46 70 45 24 22 39 12 20.8
3TD47 70 63 28 30 55 14 24.3
3TD48 90 75 34 37 67 17 29.5
3TD49 90 85 42 45 67 21 36
3TD50 150 110 54 55 100 27 46.9
3TD51 150 140 68 75 100 35 60
3TD52 180 170 75 90 156 38 66
3TD53 220 205 96 110 156 50 86
3TD54 300 250 110 132 235 58 100
3TD 50 3TD55 300 300 125 160 235 66 114

D-11 SHCET
AC
Contactor
3TH Auxiliary Contactor

Application
The auxiliary contactor is the auxiliary suited by controlled circuit whose voltage is AC
50/60Hz, 660V and DC 660V. They control all kinds of magnetic coil and amplify or
transfer signal to relative controlled element simultaneously. They are characterized by
high performance & long service life.

Specifications

Type of Contact
Type
NO NC
3TH 80 40-0A 4
31-0A 3 1

Contactors
3TH80 22-0A 2 2
13-0A 1 3
04-0A 4
80-0A 8
71-0A 7 1
3TH82 62-0A 6 2
53-0A 5 3
44-0A 4 4

LX1 Bobbin of AC Contactor

Specifications
LX1-D2: Used for Contactor CJX1-D09 to LC1-D18
LX1-D4: Used for Contactor CJX1-D25 to LC1-D32
LX1-D6N
LX1-D6: Used for Contactor CJX1-D40 to LC1-D95
LX1-FF: Used for Contactor CJX1-F115 to LC1-F150
LX1-FG: Used for Contactor CJX1-F185 to LC1-F225
LX1-FH: Used for Contactor CJX1-F265 to LC1-F330
LX1-FJ: Used for Contactor CJX1-F400
LX1-FK: Used for Contactor CJX1-F500
LX1-FL: Used for Contactor CJX1-F630
LX1-FK(1): Used for Contactor CJX1-F780

LX1-D2 LX1-FK LX1-FJ

SHCET D-12
LA Auxiliary Contact Block

Application
LA series auxiliary contact blocks are installed on the top of CA2-D control relay CJX1-
K or CJX1-D AC contactor respectively for expanding the couples of auxiliary contacts
points. Owing to adopting the contacting functions of sliding frictions, the item can be
self-cleaning & ensure the electric circuit to be reliable.

Specifications
Type Type of Contact
LA1-DN01 1NC
LA1-DN11 LA1-DN22 LA1-DN02 2NC
LA1-DN10 1NO
LA1-DN11 NO+NC
LA1-DN20 2NO
LA1-DN22 2NO+2NC
LA1-DN40 4NO
LA1-DN04 4NC
LA1-DN13 1NO+3NC
LA1-DN31 3NO+1NC
LA8-DN11 1NO+1NC
LA8-DN20 2NO
LA1-KN11 NO+NC
LA1-KN20 2NO
LA8-DN11 LA1-KN02 2NC
LA1-KN22 2NO+2NC
LA1-KN31 3NO+1NC
LA1-KN13 1NO+3NC
LA1-KN40 4NO
LA1-KN04 4NC

LA2-D Delay Timer

Application
LA1-KN22
LA2-D delay timer is applicable to be LC1-D AC contactor & CJX1-DN Auxiliary contact
block into LC3-D star-delta reduced voltage starter is to start motor.

Specifications

Type Delay range Number of the delay contacts


LA2-DT0 0.1~3s
LA2-DT2 0.1~30s
LA2-DT4 10~180s
NO+NC
LA3-DR0 0.1~3s
LA3-DR2 0.1~30s
LA2-DT2 LA3-DR4 10~180s

D-13 SHCET
AC
Contactor
New Mould Contactor

Application
New mould contactor is suitable for using in the circuits voltage up to 660V 50Hz or
60Hz, rated current up to 150A, for making & breaking, and for frequent starting &
controlling the motor.
The product has the features of small volume, light weight, low power consumption,
high efficiency, safety, reliability etc. It also can be combined with contact head group,
timer delay block, relay, thermal relay accessories, into motor starter etc, multiseries
products. It conforms with IEC60947-4.

KT6012/KT6022 100A,160A

Contactors
DC contactor: KM 25A, 50A, CJ12B-1 100A 160A, 250A
KT6013/KT6023 100A,160A 100A 200A 400A 600A 400A, 630A

CJ12B-2 100A,160A CJ12A 100A,160A, 250A


DC contactor: CZ0 80A
250A, 400A,630A 400A,630A

CJ24 100A,160A, 250A, 400A, BP32 Isolating switch: 100A, 250A,


KTPV-623
630A 400A, 630A

SHCET D-14
A AC Contactor

Application

A AC contactor is mainly used in power system with AC 50/60Hz,the rated operating current
from 9A to 110A, the rated working voltage up to 660V under the application category of AC
3, for the long-distance range making and breaking the electric circuit. When it is combined
with the suitable thermal overload relay and other necessary accessories, it becomes as
electro magnetic starter to protect against the possible overload occurs in electric circuit
during operation.

Specifications
Rated Conventional AC-3 Rated Operat- AC-3 Control the Max.
Frame
Type Insulation Free Air Heat ing Current Ie (A) Power KW of Generator
Code
Voltage (V) Current Ith (A) 220V 380V 660V 220V 380V 660V
A-9 A-9 26 9 9 7 2.2 4 5.5
A-12 16 28 12 12 9 3 5.5 7.5
A-16 30 17 17 10 4 7.5 9
A-26 26 45 26 26 17 6.5 11 15
A-30 65 32 32 21 9 15 18.5
40
A-40 65 37 37 25 11 18.5 22
A-50 100 50 50 35 15 22 30
A-63 75 125 65 65 43 18.5 30 37
A-75 1000 125 75 75 46 22 37 40
A-95 145 96 96 65 25 45 55
110
A-110 160 110 110 82 30 55 75
A-145 145 275 145 145 125 45 75 110
A-185 185 275 185 185 145 85 90 132
A-210 210 350 210 210 175 59 110 160
A-260 260 400 260 260 208 80 140 200
A-300 300 500 305 305 265 90 160 250

A-300 S-N AC Contactor

Application

S-N series AC contactors are suitable for AC 50Hz or 60Hz, rated voltage up to 660V,
mainly used as putting through long distance, breaking circuit and frequently starting or
controlling AC motor. It can also be used for counter-connection breaking of squirrel-
cage motor in the case of reducing working current.

Specifications
Capacity of 3 phase squirrel-cage motor AC-3 Rated
heating
Type Rated power (KW) Rated operating current(A)
current
220V-240V 380V-440V 550V 660V 220V-240V 380V-440V 500V 660V Ith(A)
S-N10 2.5 4.0 4.0 4.0 11 9 7 5 20
S-N11 3.5 5.5 5.5 5.5 13 12 9 7 20
S-N12 3.5 5.5 5.5 5.5 13 12 9 7 20
S-N20 5.5 11 11 7.5 22 22 17 9 32
S-N25 S-N21 5.5 11 11 7.5 22 22 17 9 32
S-N25 8.5 14 14 14 30 30 12 12 40
S-N35 12 20 20 20 40 40 17 17 40

D-15 SHCET
AC
Contactor
GMC AC Contactor

Application

GMC series AC Contactor is suitable for using in the circuits up to the rated voltage
660V AC 50Hz or 60Hz, rated current up to 95A, for making, breaking, frequently start-
ing & controlling the AC motor. Combined with the auxiliary contact block, delay timer
& machine-interlocking device etc, it becomes the delay contactor, mechanical inter-
locking contactor, star-delta starter. With the thermal overload relay, it is combined into
the electromagnetic starter. The Contactor is produced according to IEC60947-4.

GMC-12
Specifications
Life time
AC3 duty

Contactors
AC1 (x 104) Aux.
Type
duty contact
200~240V 380~440V 500~550V 690V Electrical Mechanical

GMC-9 20A 2.5kW 11A 5kW 9A 4kW 7A 4kW 5A 250 2500

GMC-12 20A 3.5kW 13A 5.5kW 12A 7.5kW 12A 7.5kW 9A 250 2500
1NO1NC
GMC-18 25A 4.5kW 18A 7.5kW 18A 7.5kW 13A 7.5kW 9A 250 2500

GMC-22 32A 5.5kW 22A 11kW 22A 15kW 22A 15kW 18A 250 2500

GMC-22
GMC-32 50A 7.5kW 32A 15kW 32A 18.5kW 28A 18.5kW 21A 200 1500

GMC-40 60A 11kW 40A 18.5kW 40A 22kW 32A 22kW 25A 200 1500

GMC-50 80A 15kW 55A 22kW 50A 30kW 43A 30kW 33A 200 1000
2NO2NC
GMC-65 100A 18kW 65A 30kW 65A 37kW 60A 37kW 47A 200 1000

GMC-75 110A 22kW 75A 37kW 75A 45kW 64A 45kW 47A 200 1000

GMC-85 135A 25kW 85A 45kW 85A 45kW 75A 45kW 52A 200 1000

GMC-40 Auxiliary For AC Contactor GMC

GMC-75 AU-2 AU-4

SHCET D-16
LR2-D Thermal Overload Relay

Application
This series of thermal overload relay can be used in the circuit of 50Hz or 60Hz, rated
insulation voltage 660V, rated current 0.1-93A for protecting the phase break when the
electric motor is overload.
The relay has different mechanism and temperature compensation & can be pluged in
CJX1-D series AC contactor. It is the most advanced thermal relay in the nineties in the
world. The products comply with IEC 60947-5.

Characteristics
LR2-D13 a. Fundamental parameter of the main circuit
(a). Rated insulation voltage 660V.
(b). Rated working current 25,36,93A separately.
(c). The regulator seal of rated setting current.
(d). Current of the Thermal component (see list 1)
b. Auxiliary Circuit
(a). There is one pair of N/O and N/C contact with electric insulation.
(b). Rated insulation Voltage 500V.
(c). Rated frequency 50-60Hz.
(d). Use group, rated working voltage, appoint thermal current and rated current.

Specifications
Thermal component
Type Rated working current Rated current Regular or scale of
(A) rated current (A)
LR2-D 1301 0.16 0.10-0.16
1302 0.25 0.16-0.25
1303 0.40 0.25-0.40
LR2-D23 1304 0.63 0.40-0.63
1305 1.0 0.63-1.0
1306 1.6 1.0-1.6
LR2-D13 25 1307 2.5 1.6-2.5
1308 4.0 2.5-4.0
1310 6.0 4.0-6.0
1312 8.0 5.5-8.0
1314 10.0 7.0-10.0
1316 13.0 9.0-13.0
1321 18.0 12.0-18.0
1322 25.0 17.0-25.0
LR2-D 2353 32 23.0-32.0
LR2-D23 36
2355 36 28.0-36.0
LR2-D 3353 32 23.0-32.0
3355 40 30.0-40.0
3357 50 37.0-50.0
LR2-D33 93 3359 65 48.0-65.0
3361 70 55.0-70.0
3363 80 63.0-80.0
LR2-D33 3365 93 80.0-93.0

D-17 SHCET
Thermal
Overload Relay
Dimensions

LA7-D1064

Thermal Overload Relays


LA7-D2064

LA7-D3064

LR2-F Electronic Thermal Overload Relay

Specifications
Type Number Setting range For contactor
F5357 30-50 F115-F185
F5363 48-80 F115-F185
LR2-F53 F5367 60-100 F115-F185
F5369 90-150 F115-F185
F5371 132-220 F225-F265
F7375 200-330 F330-F500
LR2-F73 F7379 300-500 F330-F500
LR2-F53 F7381 380-630 F400-F630

Dimensions

LR2-F73

SHCET D-18
LRD Thermal Overload Relay

Application
This series of thermal overload relay can be used in the circuit of 50Hz or 60Hz, rated
insulation voltage 660V, rated current 0.1-140A for protecting the phase break when
the electric motor is overload.
The relay has different mechanism and temperature compensation & can be pluged in
CJX1-D series AC contactor. It is the most advanced thermal relay in the nineties in the
world. The products comply with IEC 60947-5.

Specifications
LRD-13 Thermal component
Type Rated working current Rated current Regular or scale of
(A) rated current (A)
LRD 1301 0.16 0.10-0.16
1302 0.25 0.16-0.25
1303 0.40 0.25-0.40
1304 0.63 0.40-0.63
1305 1.0 0.63-1.0
1306 1.6 1.0-1.6
LRD13 25 1307 2.5 1.6-2.5
1308 4.0 2.5-4.0
1310 6.0 4.0-6.0
1312 8.0 5.5-8.0
1314 10.0 7.0-10.0
1316 13.0 9.0-13.0
1321 18.0 12.0-18.0
LRD-23
1322 25.0 16.0-24.0
LRD 2332 32 23.0-32.0
LRD23 38
2335 38 30.0-38.0
LRD 3322 25 17.0-25.0
3353 32 23.0-32.0
3355 40 30.0-40.0
3357 50 37.0-50.0
LRD33 140
3359 65 48.0-65.0
3361 70 55.0-70.0
3363 80 63.0-80.0
3365 104 80.0-104.0
3367 120 95.0-120.0
3369 140 110.0-140.0
LRD 4365 104 80.0-104.0
LRD43 140 4367 120 95.0-120.0

LRD-33 4369 140 110.0-140.0

D-19 SHCET
Thermal
Overload Relay
LR1-D Thermal Overload Relay

Application
LR1-D series thermal overload relay is suitable for thermal protection in the circuit with
AC 50 or 60Hz, voltage up to 660V, motor power up to 45KW or less. It has different
attachment and temperature compensating function. It can be fixed onto contactor and
can also be fixed independently. The product is made in accordance with IEC 60947-5.

Specifications

Adjusting
Control power (AC) (KW) Plug-in
range of
LR1-09314 Type
current contactor

Thermal Overload Relays


220V 380V 415V 440V 660V
(A)
LR1-D CJX1-
0.1~0.16
09301 D09-25
LR1-D CJX1-
0.16~0.25
09302 D09-25
LR1-D CJX1-
0.25~0.40
09303 D09-25
LR1-D CJX1-
0.40~0.63 0.37
09304 D09-25
LR1-D CJX1-
0.63~1 0.55
09305 D09-25
LR1-D CJX1-
1~1.6 0.37 0.55 0.7~1.1
09306 D09-25
LR1-D CJX1-
1.6~2.5 0.37 0.55~0.75 1.1 0.55~0.75 1.5
09307 D09-25
LR1-D CJX1-
2.5~4 0.55~0.75 1.1~1.5 1.5 1.5 2.2~3
09308 D09-25
LR1-D CJX1-
4~6 1.1 2.2 2.2 2.2 4
09310 D09-25
LR1-40355 LR1-D CJX1-
5.5~8 1.5 3 3 3 5.5
09312 D09-25
LR1-D CJX1-
7~10 2.2 4 4 4 7.5
09314 D09-25
LR1-D CJX1-
10~13 3 5.5 5.5 5.5 10
09316 D09-25
LR1-D CJX1-
13~18 4 7.5 9 9 15
16321 D09-25
LR1-D CJX1-
18~25 5.5 11 11 1 18.5
25322 D09-25
LR1-D CJX1-
23~32 7.5 15 15 15 22
40353 D40 50 65
LR1-D CJX1-
30~40 10 18.5 22 2 30
40355 D40 50 65
LR1-D CJX1-
38~50 11 22 25 25 37
63357 D40 50 65
LR1-D CJX1-
48~57 15 25 30 30 45
63359 D40 50 65
LR1-D CJX1-
57~66 18.5 30 37 37 55
63361 D80 95
LR1-D CJX1-
63~80 22 33~37 33~37 33~37 59~63
80363 D80 95

SHCET D-20
3UA Thermal Overload Relay

Application
3UA series thermal overload relay is suitable for using in power system with AC 50/
60Hz, rated operation voltage up to 660V and 1000V, current from 0.1A to 630A. It is
used to protect AC three-phase asynchronous motor against overload and open-phase.
The current setting value can be regulated and the setting current values of many ther-
mal elements are intercrossing overlepping arrangement, for easy selecting by the cus-
tomers from -25C to +55C air temperature as the products have temperature
compensating. The relays have the test push-button for breaking NC contacts, the op-
erating indication and free trip characteristics. The items conform to IEC60947-5.

3UA50

Specifications

Rated operating Rated insulation


Type Current setting range (A)
current (A) voltage (V)

0.1~0.16, 0.16~0.25, 0.25~0.4, 0.32~0.63,


0.63~1.0, 0.8~1.25, 1.0~1.6, 1.25~2.0,
3UA50 12.5 660
1.6~2.5, 2.0~3.2, 2.5~4.0, 3.2~5.0,
4.0~6.3, 5.0~8.0, 6.3~10.0, 8.0~12.5
0.1~0.16, 0.16~0.25, 0.25~0.4, 0.4~0.63,
0.63~1.0, 0.8~1.25, 1.0~1.6, 1.25~2.0,
3UA52 25 660 1.6~2.5, 2.0~3.2, 2.5~4.0, 3.2~5.0,
4.0~6.3, 5.0~8.0, 6.3~10.0, 8.0~12.5,
10.0~16.0, 12.5~20.0, 16.0~25.0
4.0~6.3, 6.3~10.0, 10.0~16.0, 12.5~20.0,
3UA54 32 660
16.0~25.0, 20.0~32.0, 25.0~36.0

3UA52 16.0~25.0, 20.0~32.0, 25.0~40.0, 32.0~50.0,


3UA58 80 1000
40.0~57.0, 50.0~63.0, 57.0~70.0, 63.0~80.0
0.1~0.16, 0.16~0.25, 0.25~0.4, 0.4~0.63,
0.63~1.0, 0.8~1.25, 1.0~1.6, 1.25~2.0,
1.6~2.5, 2.0~3.2, 2.5~4.0, 3.2~5.0,
3UA59 63 660
4.0~6.3, 5.0~8.0, 6.3~10.0, 8.0~12.5,
10.0~16.0, 12.5~20.0, 16.0~25.0, 20.0~32.0,
25.0~40.0, 32.0~45.0, 40.0~57.0, 50.0~63.0
55.0~80.0, 63.0~90.0,
80.0~110.0, 90.0~120.0,
3UA62 180 660
110.0~35.0, 120.0~150.0,
135.0~160.0, 150.0~180.0
80.0~125.0, 125.0~200.0,
3UA66 400 1000 180.0~250.0, 200.0~320.0,
250.0~400.0
3UA68 630 1000 320.0~500.0, 400.0~630.0

3UA58

D-21 SHCET
Thermal
Overload Relay
GTH Thermal Overload Relay

Application
This series of thermal overload relay can be used in the circuit of 50/60Hz, rated insu-
lation voltage 660V, rated current 0.1-85A for protecting the phase break when the
electric motor is overload.
The relay has different mechanism and temperature compensation & can be pluged in
GMC series AC contactor. The products comply with IEC 60947-5.

Specifications
GTH-22
Thermal component

Thermal Overload Relays


Type Rated current Regular or scale of rated
(A) current (A)
0.14 0.10-0.16
0.21 0.16-0.25
0.33 0.25-0.40
0.52 0.40-0.63
0.82 0.63-1.0
1.3 1.0-1.6
GTH-22 2.1 1.6-2.5
3.3 2.5-4.0
5 4.0-6.0
6.5 5.0-8.0
7.5 6.0-9.0
8.5 7.0-10.0
11 9.0-13.0
15 12.0-18.0
19 16.0-22.0
5 4.0-6.0
GTH-40 6.5 5.0-8.0
7.5 6.0-9.0
8.5 7.0-10.0
GTH-40 11 9.0-13.0
15 12.0-18.0
19 16.0-22.0
22 18.0-26.0
30 24.0-36.0
34 28.0-40.0
8.5 7.0-10.0
11 9.0-13.0
15 12.0-18.0
19 16.0-22.0
22 18.0-26.0
GTH-85 30 24.0-36.0
34 28.0-40.0
42 34.0-50.0
55 45.0-65.0
65 54.0-75.0
GTH-85 74 63.0-85.0

SHCET D-22
JR28 Thermal Overload Relay

Application
JR28 Thermal Overload Relay is applicable to protect overload and open-phase of
long-time continuous or discontinuous working AC motor in the circuit of AC 50/60Hz,
current up to 630A, voltage up to 690V. It has features of temperature compensation,
action indication, manual and automatic restoration.

Specifications
Rated Operation Rated Working Rated insulating Suitable
Model
Cuttent (A) Voltage (Ue) max (V) Voltage (Ui) (V) Comtactor
80-125 380 690 CJX1-Y115
JR28-200 100-160 380 690 CJX1-Y150
125-100 380 690 CJX1-Y185
160-250 380 690 CJX1-Y225
JR28-200 200-315 380 690 CJX1-Y265
JR28-630 250-400 380 690 CJX1-Y330/440
315-500 380 690 CJX1-Y500
400-630 380 690 CJX1-Y630

Overall And MOunting Dimensions

JR28-200 Independent Style

JR28-630 Independent Style

JR28-630

*Before / is JR28-400/630 size.


After / is JR28-500/630, 630/630 size.

D-23 SHCET
Magnetic Starter

LE1-N Magnetic Starter

Application
LE1-N magnetic starter is mainly applied to circuit of AC 50 or 60Hz, voltage up to 550V
for far distance making and breaking circuit and frequently starting and controlling motor.
It has the features of small volume, light weight, low power consumption, high efficiency,
safe and reliable performance etc.

Specifications
LE1-N09
Maximum power AC3 duty(KW) Rated Type of Code number Suitable
220V 380V 660V current enclo- LL NL(3) thermal
415V 440V 500V
690V (A) sure relay (A)

Starters
230V 400V (long life) (normal life)
IP42 LE1-N094.. LR2-D1312
2.2 4 4 4 5.5 5.5 9
IP65 LE1-N093.. LR2-D1314
IP42 LE1-N124.. LE1-N094..
3 5.5 5.5 5.5 7.5 7.5 12 LR2-D1316
IP55 LE1-N123.. LE1-N093..
IP42 LE1-N188.. LE1-N124..
4 7.5 9 9 10 10 18 LR2-D1321
IP55 LE1-N185.. LE1-N123..
IP42 LE1-N258.. LE1-N188.. LR2-D1322
5.5 11 11 11 5 15 25
IP55 LE1-N255.. LE1-N185.. LR2-D2353

7.5 15 15 15 18.5 18.5 32 IP55 LE1-N325.. LE1-N255.. LR2-D2355

LR2-D3353
11 18.5 22 22 22 30 40 IP55 LE1-N405.. LE1-N325..
LR2-D3355
LR2-D3357
15 22 25 30 30 33 50 IP55 LE1-N505.. LE1-N405..
LR2-D3359

18.5 30 37 37 37 37 65 IP55 LE1-N655.. LE1-N505.. LR2-D3361


LE1-N18
LR2-D3363
22 37 45 45 55 45 80 IP55 LE1-N805.. LE1-N655..
LR2-D3365

25 45 45 45 55 45 95 IP55 LE1-N955.. LE1-N805.. LR2-D3365

Double insulated, protected to IP 42


LE1-N09 and N12
(3) or to IP 659(4)
Double insulated, protected to IP427
Enclosure LE1-N18 and N25
(3) or to IP 557(4)

LE1-N32...N95 Metal, IP 55 to IP 559

Control(2 pushbuttons mounted 1 green Start button I


LE1-N09...N95
on enclosure cover) 1 red Stop/Reset button O
Pre-wired power and control circuit
Connections LE1-N09...95
connections

Standard control circuit voltages


Volts 24 42 48 110 220/230 230 240 380/400 400 415 440
LE1-N32 50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

SHCET D-24
LE1-D Magnetic Starter

Application
LE1-D magnetic starter is mainly applied to circuit of AC 50 or 60Hz, voltage up to 550V
for far distance making and breaking circuit and frequently starting and controlling motor.
It has the features of small volume, light weight, low power consumption, high efficiency,
safe and reliable performance etc.

Specifications

Maximum power AC3 duty(KW) Rated Type of Code number Suitable


LE1-D09
220V 380V 660V current enclo- LL NL(3) thermal
415V 440V 500V
230V 400V 690V (A) sure (long life) (normal life) relay (A)

IP42 LE1-D094.. LR2-D1312


2.2 4 4 4 5.5 5.5 9 IP65 LE1-D093.. LR2-D1314
IP42 LE1-D124.. LE1-D094..
3 5.5 5.5 5.5 7.5 7.5 12 LR2-D1316
IP55 LE1-D123.. LE1-D093..
IP42 LE1-D188.. LE1-D124..
4 7.5 9 9 10 10 18 LR2-D1321
IP55 LE1-D185.. LE1-D123..
IP42 LE1-D258.. LE1-D188.. LR2-D1322
5.5 11 11 11 5 15 25 IP55 LE1-D255.. LE1-D185.. LR2-D2353

7.5 15 15 15 18.5 18.5 32 IP55 LE1-D325.. LE1-D255.. LR2-D2355

LR2-D3353
11 18.5 22 22 22 30 40 IP55 LE1-D405.. LE1-D325..
LR2-D3355
LR2-D3357
15 22 25 30 30 33 50 IP55 LE1-D505.. LE1-D405..
LR2-D3359

18.5 30 37 37 37 37 65 IP55 LE1-D655.. LE1-D505.. LR2-D3361

LR2-D3363
LE1-D25 22 37 45 45 55 45 80 IP55 LE1-D805.. LE1-D655..
LR2-D3365

25 45 45 45 55 45 95 IP55 LE1-D955.. LE1-D805.. LR2-D3365

Standard control circuit voltages


Volts 24 42 48 110 220/230 230 240 380/400 400 415 440
50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

Dimensions

LE1-D95

D-25 SHCET
Magnetic Starter

LC3-D Star-delta Reduced Voltage Starter

Application
LC3-D series star-delta reduced voltage starter is suitable for starting motor in the cir-
cuit of AC 50/60Hz, voltage up to 660V and current up to 95A. It is provided with a timer
for automatic changeover of star-delta to reduce the voltage and current of motor starting.

Specifications
LC3-D183 Rated operating current (A) 3-phase motor capacity(kw)
Type AC3 Loaded
AC3
220V 380V 415V 440V

Starters
LC3-D093 9 4 7.5 7.5 7.5
LC3-D123 12 5.5 11 11 11
LC3-D183 18 11 18.5 22 22
LC3-D253 25 11 22 22 22
LC3-D323 32 15 25 30 30
LC3-D403 40 18.5 37 37 37
LC3-D503 50 30 55 59 59
LC3-D653 65 32 55 59 59
LC3-D803 80 37 75 75 75
LC3-D953 95 45 80 80 80

Wiring Diagram
LC3-D503

LC3-D803

SHCET D-26
AD Magnetic Starter and Star-delta Starter

Specifications
3-phase motor capacity
Type Rated current
AC3 load 415V
AC3 415V(A)
KW HP
0.74-1.11 0.37 0.50
1.11-1.66 0.55 0.75
1.66-2.50 1.10 1.50
Direct-on-line, surface mounting
2.50-3.70 1.50 2.00
Direct-on-line, flush mounting
3.70-5.60 2.50 3.40
Direct-on-line, surface mounting, reversing
5.60-8.40 4.00 5.50
ADS7 Direct-on-line, surface mounting, with isolator
8.40-11.9 5.50 7.50
ADE7
11.4-16.0 7.50 10.0
ADS7
16.0-23.0 11.0 15.0
22.0-33.0 15.0 20.0
4.30-6.40 3.00 4.00
6.40-9.70 5.00 6.80
9.70-14.5 7.50 10.0
Star-del ta, surface mounting
14.5-20.6 10.0 13.5
ADE
19.7-27.7 15.5 20.0
26.0-38.0 22.0 30.0

SRCa Magnetic Starter


Application
SRCa Magnetic Starter is mainly applied to circuit of AC 50Hz or 60Hz, voltage up to
ADE 550V for far distance making and breaking circuit and frequently starting and control-
ling motor. It has the features of small volume, light weight, low power consumption,
high efficiency, safe and reliable performace etc.

Specifications

Rated Ultimate Rated Current AC1


Type Single-phase motor AC3 duty AC3 duty duty
110V 220V 220~220V 380~440V 500~550V 220~220V 380~400V 500~550V A
SRCa-9B 0.4 0.8 2.5 4 4 11 9 7 20
SRCa-12B 0.5 1 3.5 5.5 7.5 12 12 12 20
SRCa-18B 0.75 1.5 4.5 7.5 7.5 18 18 13 25
SRCa-22B 0.9 1.8 5.5 11 15 22 22 22 32
SRCa-32B 0.9 1.8 5.5 11 15 22 22 22 32
SRCa-40B 0.9 1.8 5.5 11 15 22 22 22 32
SRCa (Plastic)
SRCa-50B 0.9 1.8 5.5 11 15 22 22 22 32
SRCa-65B 0.9 1.8 5.5 11 15 22 22 22 32
SRCa-75B 0.9 1.8 5.5 11 15 22 22 22 32
SRCa-85B 0.9 1.8 5.5 11 15 22 22 22 32

D-27 SHCET
SHANGHAI CET ELECTRIC CO.,LTD.
SHCET GROUP
SHCET GROUP
SHANGHAI CET ELECTRIC CO.,LTD.

Foreign Trade Department:No.2451,Xietu Road,Xuhui District Shanghai.China.200080


Factory Add:XinGuang District, YueQing City,Zhejiang Province,China.
Tel:0086-21-64280271
Mob:0086-13524081636
Fax:0086-21-54240680
Website:www.cetelec.com.cn
E-mail:cet@cetelec.com.cn / wfs1079@163.com
MSN:wfs1079@hotmail.com

C Copyright SHCET GROUP All Rights Reserved.

You might also like