You are on page 1of 1

4.29 5.

98
STAMP AND DATE OF APPROVAL
PLOT AREA DIAGRAM B
SR. BASE HEIGHT AREA 18.15
6.27 4.06
NO 7.59
3.83
1 0.5 33.89 23.86 404.3 SQ.M 1.5
UP 1.37
1.66 B C BLOCK NAME LENGTH IN M WIDTH IN M AREA IN SQ.M
2 0.5 33.64 12.03 202.3 SQ.M 1.80 1.80 S1 1.37

3 0.5 33.64 24.04 404.4 SQ.M A A A 15.72 18.15 285.31 SQ.M


4.90

23,8
6
4 0.5 26.74 11.64 155.6 SQ.M
KITCHEN
2.0 X 2.61M G B 1.66 6.27 10.40 SQ.M
52 5 0.66 12.11 1.26 10.07 SQ.M LIVING ROOM
5.94

1 M WIDE PASSAGE
3.24

33,8
1 ,2
6
3.00 0.30 4.33 X 3.13M C 1.37 7.59 10.39 SQ.M
6 0.66 12.31 3.15 25.5 SQ.M BATH

33,8
(1 BHK) 1.2 X 1.5M

9
9
TOTAL PLOT AREA 1202 SQ.M D 10.65 1.61 17.14 SQ.M
1.38 WC
0.9 X 1.2M E 1.61 3.62 5.82 SQ.M
DOOR SCHEDULE

LIFT
1.53
F L1 D.NO. SIZE DESCRIPTION
F.R.D F 3.53 3.26 11.50 SQ.M
3.53 10.69 D1 900 x 2100 MATERIAL: TEAKWOOD

2.27
1.5 M WIDE LOBBY BEDROOM
2.38 X 3M
3.53 3.30
A D 10.69
G 3.24 6.27 20.31 SQ.M
SINGLE SHUTTER SOLIDE PANNEL
DOOR FINISH: MELAMINE POLISH

LIFT
1.53

26,
4
,6
2 D2 750 x 2100 MATERIAL: TEAKWOOD

33
1.65 FIRE ELEC

74
4 SINGLE SHUTTER, SOLIDE PANNEL,
1.38 DUCT DUCT 24.07SQ.M
24 15.73 S1 5.93 4.06 DOOR FINISH: LAMINATE
,0
4 3.26 2.89 D1 0.60
12 DUCT

2.5 X 1.25M

2.5 X 1.25M
,0 64
3 11, 2.5 X 2.5M L1 3.29 2.89 9.50SQ.M
3
E WINDOW SCHEDULE

12
3,1
5 1
D2
,31
,1
12

87

T
14 6 1.50SQ.M

7,
3.63 LIVING ROOM LIVING ROOM D1 0.60 2.5 CILL
W.NO. SIZE
,3
3 5 3.5 X 4.3M 3.5 X 4.3M
3.63
2.50 LEVEL DESCRIPTION
(2 BHK) (2 BHK) 6.25 SQ.M
32,54 4,6
4 D2 2.5 2.5 W1 2500 x 1200 900
ALLUMINIUM SLIDING WINDOW
WITH FIVE GLASS PANNEL
1.62 1.62
ALLUMINIUM SLIDING WINDOW

1,
T T 2500 X 1500 600

26
W2 WITH FIVE GLASS PANNEL
B.ROOM
1.2 X 2.61M 1.2 X 2.61M 2.50 TOTAL DEDUCTIONS 116.88SQ.M ALLUMINIUM SLIDING WINDOW
0.53 X 0.76M
B.ROOM
0.53 X 0.76M W3 1000 X 1200 900
WITH FOUR GLASS PANNEL
N 1.62
1.62 BUA OF ONE FLOOR (A -TOTAL DEDUCTION) 168.43SQ.M V1 750 x 600 1500
ALLUMINIUM FRMAED GLASS
LOUVERED VENTILATORS
PROPOSED SITE 3.66 BEDROOM KITCHEN

PLOT AREA DIAGRAM


BEDROOM BEDROOM KITCHEN BEDROOM 3.66
3.2 X 3.1M 1.8 X 3.3M 2.7 X 3.4M 2.7 X 3.4M 1.8 X 3.3M 3.2 X 3.1M
LIGHT AND VENTILATION
STATEMENT
(1:500) ROOM
CARPET AREA OF AREA OF
AREA WINDOW WINDOW
OF REQUIRED PROVIDED
ROOM (1/6TH OF
B CARPET
AREA LINE DIAGRAM AREA)
RECREATIONAL GROUND 15% = 180 SQM

TYPICAL FLR. PLAN (1st TO 7th & 9th TO 13th) (1:100)


1BHK
LIVING ROOM 14.25 2.28 4.2 SQ.M

(1:100) BEDROOM 10.15 1.62 1.65 SQ.M

900
52
.2 KITCHEN 7.12 1.13 1.5 SQ.M

33.8
59
11.84
8 2BHK
4.28 LIVING ROOM 18.67 2.98 3 SQ.M
3.26 1.51 1.50 4.29 7.60
4.07 8.87 BEDROOM 1 13.33 2.13 2.4 SQ.M
3.83
UP 1.37
1.5 KITCHEN 13.5 2.16 1.8 SQ.M
5.98
D2 D3
4.61 1.80 1.80 BUILT UP AREA: STILT BEDROOM 2 9 1.44 2.4 SQ.M

3
BUILDING
(A) AREA OF BLOCK: 20.2 X14.0=282.8
ENTRY TO THE STAIRCASE 17.72
4.91
4.61
D4 (B) STANDARED DEDUCTIONS
2.28 3 SQ.M
15.75 LOBBY 27.3 4.68 3
6.84 0.0M
0.30 D1 SR. LENGHT BREADTH NOS AREA UNIT
8.67
NO PARKING SCHEDULE
6.35
1.38 UP

A D1 15.72 3.26 1 51.34 SQ.M


1 PARKING REQUIRED FOR 2FLATS OF 2BHK

LIFT
0.45M
1.53 D2 4.90 1.50 1 7.39 SQ.M
F.R.D
1 PARKING REQUIRED FOR 4FLATS OF 1BHK
3.30 10.69 D3 4.60 1.49 1 6.89 SQ.M
UGT
TOTAL NO. OF 2BHK FLATS: 12
D4 8.66 7.60 1 65.86SQ.M

46
0.89 0.89 3.76

LIFT
TOTAL NO. OF 1BHK FLATS: 23

78
1.53
0.30M FIRE ELEC D5 1.06 2.96 1 3.13SQ.M

7.
4.18
4.27 1.61 1.38 UP 1.06 DUCT DUCT
1.06
15.73
TOTAL NO. OF PARKING: 6+6= 12
D6 7.05 14.88 1 105.10SQ.M
2.50 D5 1.06 NO. OF VISITOR PARKING TO BE PROVIDED =
00
4 .52 2.96
TOTAL DEDUCTIONS (B)=239.71 SQ.M 1/10TH OF PARKING
7.1600 32.5600 0.15M
7.29
NET AREA : (A)-(B) =48.87 - 239.71 = 190.84 SQ.M REQUIRED VISITOR PARKING= 1.2(10% OF 12)
3.63
DUCT
PROVIDED VISITOR PARKNG: 2 :4-WHEELER
6 :2-WHEELER
D5
SITE BLOCK PLAN 1.62 1.62

7.06
BUILT UP AREA
RECREATIONAL GROUND 15% = 180 SQM
(1:250) 3.66
1 2 3.66
RCC COPING
230 THK BRICKWALL
PLOT AREA
LAND USE
1202
RESIDENTIAL
PERMISSIBLE RG 180 SQ.M(15% OF 1202)
12 13 14 15 PROPOSED RG 180 SQ.M
OWNERS LAND PERMISSIBLE F.S.I 2
900

18.18
PERMISSIBLE NET B.U.A
52 3.26 14.89

GROUND COVERAGE AREA


2404 SQ.M
210.05 SQ.M

.2 B.U.A OF ONE FLOOR 170.15

BUILT UP AREA: STILT PLAN STILT AREA LINE DIAGRAM


33.8

59 D.P.C
AREA UPTO 7TH FLOOR
(INCLUDING STILT)
1236.78

8 (1:100) GL
AREA OF 8TH
FLOOR(REFUGE FLOOR) 137.78

11.84
(1:100) B.U.A OF 9th TO 13th FLOOR
PROPOSED B.U.A
F.S.I CONSUMED
850.75
2257.68
1.87
U.C.R MASONRY
BALANCE AREA 146.32
150 MM THK PCC BED
4.07
4 COMPOUND WALL SHEET CONTENT
SECTION (1:50)
4.55 4.28

3.8
3.80 5 CONTENT OF SHEET
LOCATION AND BLOCK PLAN ,PLOT AREA CALCULATION
STILT PLAN ,WATER CALCULATIONS ,SECTION THROUGH
UP 1.37
1.60 1.60 COMPOUND UGT DETAIL,OHT DETAIL, GATE ELEVATION
1.5

4.61 1.8 1.8


5.98

6 NAME OF THE OWNER AND


4 25

BUILDING
3.
SIGNATURE
6
7
ENTRY TO THE
M NO. OF FLATS: 35
W
23 2

ID NO. OF PEOPLE PER FLAT: 4 APPRX.


0.0M E
D TOTAL NO. OF PEOPLE = 35X4 = 140
R
0.3

IV
EW
8 GATE ELEVATION
WATER REQUIREMENT PER PERSON PER DAY: 135 L
1 22

UP AY TOTAL WATER REQUIRED BY RESIDENTS: 140 x 135 18900


L= L
1.3

SCALE -1:20 WATER REQUIREMENT FOR LANDSCAPE S 15% OF TOTAL


0.45M
LIFT

9
1.3
20 2

15
WATER REQUIREMENT:100 X 18900 =2835 L
3.30 ENTRANCE LOBBY 10.69
6.84 0.9 0.9
MANHOLE WATER REQUIREMENT FOR FIRE FIGHTING 50000
= L
OVERFLOW TOTAL WATER: 18900+2835+50000=
71735 L
LIFT
1.5

10
8 19

0.30M FIRE ELEC 10.70


AND VENT
BAFFLE
1.1

1.1

1.61 1.3 UP DUCT DUCT DOMASTIC WATER FIRE FIGHTING


2.5
SUPPLY TANK SEPARATION WALL TANK
17 1

WALL NRV
IC
11 TO PUMP
UGT CALCULATION
2.5

3.63 0.15M TANK CAPACITY SIZE REQUIRED: 72 CUBIC METRE


4.60 SUPPLY UGT SIZE: L X B x H = 72
16

DUCT
6.35 4.2M L X B x 1.5M = 72, L=?, B=?
1.62 1.62 L X B = 48 CUBIC M TITLE: PROPOSED RESIDENTIAL BUILDING
9.20
CONSIDERING B=2L, MUNCIPAL PLOT NO- 403A
L x 2L x = 48 CUBIC METER DRAWING BEARING NO- 1355,/1-7
L(2) = 24 CUBIC M AT JUNCTION OF CENTRAL AVENUE
3.66
1 2 3.66
UGT
OHT DETAIL L= 4.9 M
UGT SIZE: L=4.9M, B= 9.8M, H=1.5M
ROAD.
CHEMBUR
IC

12 13 14 15
SCALE -1:20
46

FIRE OHT CALCULATION


78

18.18 PUMP
SUCTION
40% OF 18900 L =7560 L
VALVE FIRE FIGHTING = 50000 L
7.

4.18
4.23
IC
4.27
TOTAL = 57560 L
MANHOLE MANHOLE
MAIN
OVERFLOW SUPPLY
AND VENT
BAFFLE
TANK CAPACITY SIZE REQUIRED: 58 CUBIC M SIGN OF
WALL O.H.T SIZE = LXBXH ARCHITECT

2 0 0 DOMESTIC
WATER SUPPLY SEPARATION
FIRE
FIGHTING
CONSIDER H=2.5M AND B=2L

4.5
5.00 5.00 TANK WALL TANK 5.8X3XH = 58 DRG NO. PACK REVISION
SLOPE SLOPE

7.1600 EXIT
DC 32.5600 ENTRY
(VEHICULAR/PEDESTRIAN)
LETS ASSUME HT TO BE 2.7M,
L=5.8 M, B=3.8M, H=2.7M

N
FOOT 9.2M LxB x H = 59.5 CU. M LTIADS SEM-7
VALVE
SAGRIKA KHATIKHANDKA
MAIN PUBLIC SEWER LINE UGT DETAIL TANK CAPACITY SIZE GIVEN: 59.5 CUBIC M B1315
SCALE -1:20 ARD

You might also like