You are on page 1of 1

S S S

19 20 21

UP 48
DOWN S S
S S S
S3W S3W
S3W S3W
40

S S S S
S S3 S3 S
29 54
11 15
S S S S
S S
1 6

25 30 27
S S S S

35 36 S S
2 7
S S
S S S S
12 16
S S
S S S S

3 8 S S S S
S S3 S3 S

13 17

31

S S
S
S S
4 9 S S
S S
S S S
14 18 S
37 38 S S

5 10
S S
33 34 41 44 45
42
43 49
32
26 28 46

39
S3W S3W
S3W S3W 50
49 S S S
S S

22 23 24
47
MDP 50 S S S

POWER LAYOUT POWER LAYOUT LIGHTING LAYOUT LIGHTING LAYOUT


GROUND FLOOR FIRST FLOOR GROUND FLOOR FIRST FLOOR
SCALE 1:175 mm SCALE 1:175 mm SCALE 1:175 mm SCALE 1:175mm

FEEDERS GENERAL NOTES & SPECIFICATION


ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION OF PHILIPPINE ELECTRICAL CODE, TO THE
CKT. NO DESCRIPTION AB BC CA 3 1 RULES AND REGULATIONS OF LOCAL AND NATIONAL AUTHORITIES CONCERNED AND THE REQUIREMENTS OF
1 1 HP ACU 8.00 LOCAL UTILITY COMPANIES.

2 1 HP ACU 8.00 2 NO BRANCH CIRCUIT WIRING IN MAIN DISTRIBUTION PANEL SHALL HAVE A LOAD MORE THAN 80% OF ITS RATING.
3 1 HP ACU 8.00
ALL MATERIALS AND EQUIPMENT TO BE USED SHALL BE BRAND NEW AND OF APPROVED TYPE FOR BOTH LOCATION AND
4 1 HP ACU 8.00 3
PURPOSE.
5 1 HP ACU 8.00
MOUNTING HEIGHT AS FOLLOWS:
6 1 HP ACU 8.00
250 AMPERE
7 1 HP ACU 8.00 A. LIGHT SWITCHES -------------------------1400 mm FINISH FLOOR LINE (F.F.L) 3 PHASE, 440V
4
8 1 HP ACU 8.00 2 - 200 mm THW - 2 WIRE
B. RECEPTACLES ---------------------------- 300 mm F.F.L 1 - 150 mm THW - 2 WIRE (GROUNDING)
9 1 HP ACU 8.00 IN 65 mm RMC
10 1 HP ACU 8.00 C. PANEL BOARD ----------------------------- 1800 mm F.F.L
11 1 HP ACU 8.00
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR THE PROPER IDENTIFICATION AND LABELING OF ALL CIRCUIT BREAKER.
12 1 HP ACU 8.00 5 EACH PANEL WILL BE PROVIDED WITH A TYPEWRITTEN CIRCUIT DIRECTORY.
13 1 HP ACU 8.00 M
THE JOB SHALL BE EXECUTED IN THE MOST THROUGH PROMPT AND WORKMAN LIKE MANNER, EMPLOYING STANDARD
14 1 HP ACU 8.00 6 TOOLS, EQUIPMENTS, METHODS AND GOOD ENGINEERING PRACTICES. THE JOB SHALL BE DONE COMPLETE IN ALL
ASPECTS AS REQUIRED IN PLANS AND SPECIFICATION AND READY FOR OPERATION. 350AT MAIN AIR C.B

53
15 1 HP ACU 8.00
16 1 HP ACU 8.00
THE DRAWING AND SPECIFICATIONS ARE INTENDED TO PRESENT A GENERAL LAYOUT AND BROAD OUTLINE AND
17 1 HP ACU 8.00 7
DESCRIPTION OF THE PROJECT AND NOT NECESSARY INDICATE, DESCRIBED ACTUAL LOCATION LEVELS AND DISTANCE

18 1 HP ACU 8.00
OF EQUIPMENT. THE CONTRACTOR IS HEREBY REQUIRED TO MAKE ADJUSTMENT AT THE JOBSITE AS LOCATION, LEVELS
AND DISTANCES ARE GOVERNED BY ACTUAL FIELD CONDITIONS. ATS TO GENERATOR
19 1 HP ACU 8.00
20 1 HP ACU 8.00 NO REVISION IN THE DESIGN SHALL BE DONE WITHOUT THE PRIOR KNOWLEDGE AND APPROVAL OF THE DESIGNER AND
8 THE OWNER. ANY SUCH REVISION DONE WITHOUT THE APPROVAL SHALL CAUSE RESPONSIBILITY OF THE DESIGNER TO
21 1 HP ACU 8.00 CEASED AS A WHOLE.
22 1 HP ACU 8.00
23 1 HP ACU 8.00 9 ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DUTY LICENSED ELECTRICAL ENGINEER
AND / OR MASTER ELECTRICIAN.
24 1 HP ACU 8.00
25 C.O (EMERGENCY) 6.52
26 C.O 6.52
27 C.O 6.52 LEGENDS
28 C.O 6.52
29 C.O 6.52 DUPLEX CONVENIENCE OUTLET S SINGLE POLE SWITCH

30 C.O 6.52 SPECIAL PURPOSE OUTLET (ACU) S3 THREE POLE SWITCH


31 C.O 6.52
32 C.O 6.52 INCANDESCENT LAMP S 3W THREE-WAY SWITCH

33 C.O 6.52 M KILOWATT-HOUR METER 1 CIRCUIT HOMERUN (NUMBER IND. CKT. NO.)
34 C.O 6.52
MDP MAIN DISTRIBUTION PANEL SERVICE ENTRANCE (THREE PHASE)
35 C.O 6.52 3-W
36 C.O 6.52 SERVICE ENTRANCE (SINGLE PHASE) FLUORESCENT LAMP
2-W
37 C.O 6.52
38 C.O 6.52
39 C.O 6.52 FEEDER FEEDER FEEDER FEEDER EMERGENCY
40 C.O 6.52
41 L.O 0.43
LINE AB LINE BC LINE CA LINE 3 LOAD
42 L.O 0.43
43 L.O 0.78
44 L.O 0.52
45 L.O 0.52
46 L.O 0.87
47 L.O 0.26
48 L.O 0.26
49 L.O (EMERGENCY) 2.09
50 L.O 2.26
51 ELEVATOR 46.40
52 ELEVATOR 46.40
53 L.O 1.04
TOTAL AMPERE 100.95 101.71 103.12 92.80

LIGHTING LAYOUT
PARKING LOT
SCALE 1:175mm

DRAWN: VICTOR EMMANUEL C. ESTOMO PROJECT TITLE: SHEET CONTENTS: OWNER: SHEET NO.
LEVITA CASTAEDA
DATE: DECEMBER 8, 2016 ILLUMINATION ENGINEERING DESIGN ELECTRICAL LAYOUT PLAN VICTOR EMMANUEL C. ESTOMO
E-1
PROFESSIONAL ELECTRICAL ENGINEER
REVISED:
LOCATION: CONTRACTOR: P.R.C REG. NO. DATE:
CHECKED: P.T.R NO. DATE:
PROJECT NUMBER: DASMARIAS CITY, CAVITE ALL NEW HOMES T.I.N OWNER/MANAGER
PLACE: