Professional Documents
Culture Documents
: APCSP-BHEL-KRNP-VENT-002
NTPC DOC. NO. : 4410-001-155-PVE-B-003E
BHEL DOC. NO. :
PROJECT : NORTH KARANPURA SUPER THERMAL POWER PROJECT (3x660 MW) - CHATRA DIST., JHARKHAND
CGPowerandIndustrialSolutionsLimited
LTMotorsDivision
Ahmednagar
0.5 HP / 4 POLE (0.37 KW / 4 POLE) MOTOR DATASHEET
1 GENERAL
i Manufacturer & country of origin CG Power and Industrial Solutions Limited
ii Equipment driven by motor Tube Axial & Bifurcated Fans
iii Motor type 3 PHASE AC SQUIRREL CAGE INDUCTION MOTOR IE3
iv Quantity 11 Nos. (System: VE-9: 4nos+VE10: 3nos+VE-3: 1no
+VE-4: 1no+VE-5: 1no+VE-6: 1no)
2 DESIGN & PERFORMANCE DATA
i Frame size GD71
ii Type of duty S1
iii Type of enclosure & method of cooling TEFC Safe Area & IC 411
Degree of protection IP55
iv Applicable standard to which motor IEC 60034,IS:325,
generally confirms
v Type of mounting B3
vi Direction of rotation viewed from DE Bidirectional
vii Standard continuous rating at 40 deg.C
ambient temp. as per Indian Std. Kw 0.40
viii Derated rating for specified normal
condition i.e. 50 deg. C ambient ( Kw) 0.37
ix Rated voltage (volts) & Rated frequency(Hz) 415 & 50
x Permissible variation of
a voltage (volts) +-10%
b Frequency (Hz) +3-5%
c Combined voltage & frequency 10% ( Absolute)
xi Minimum permissible starting voltage(v) 80%
xii Rated speed at rated voltage & frequency 1400 RPM
xiii At rated voltage and frequency
a Full load current ( A ) 1.01
b No load current ( approx) ( A ) 0.6 (Indicative)
xiv Power factor at
a 100% load & 75% load & 50% load 0.66 & 0.6 & 0.5
b No load 0.15 (Indicative)
c Starting 0.4 (Indicative)
xv Efficieny (%)at rated voltage & frequency
a 100% load 77.3
b 75% load 77.3
c 50% load 74
xvi Starting current % FLC at
a 100% voltage 400
b 85% voltage 340
c 80% voltage 320
xvii Starting time with minimum permissible
voltage LOAD GD2 = 0.115
a without driven equipment coupled 0.00
b with driven equipment coupled 1.3 Sec
xviii Safe stall time with 110% of rated voltage
a From hot condition in sec. 7
b From cold condition in sec. 13
xix Torques - % FLT
a Starting torque at min. permissible V 115.2
starting torq at rated V. 180
b Pull up torque at rated voltage 155
c Pull out torque 220
d Min. accelerating torque available 10%
e Rated torque - kg-m 0.26
xx Stator winding resistance per phase 18.133 (Indicative)
(ohm/milli ohm at 20 C.) ( Indicative )
xxi GD square value of motor - kg-m sq. 0.00
xxii No. of permissible successive starts
when motor is in hot / cold condition 2/3
xxiii
a Locked rotor KVA input 2.9
b Locked rotor KVA / KW 7.85
xxiv Bearings
a Type Antifriction deep groove ball
b Manufacturer SKF/FAG/NTN/EQUIVALENT
c Self lubricated or forced lubricated Self Lubricated
d Recommended lubricants Greased for life
e Guaranteed life in hours > 40,000 hours
f Whether dial type thermometer provided NO
g Oil pressure guage/switch N.A.
i range
ii Contact Nos. and ratings
iii Accuracy
APCSP DOC.NO.: APCSP-BHEL-KRNP-VENT-002
NTPC DOC. NO. : 4410-001-155-PVE-B-003E
BHEL DOC. NO. :
PROJECT : NORTH KARANPURA SUPER THERMAL POWER PROJECT (3x660 MW) - CHATRA DIST., JHARKHAND
CGPowerandIndustrialSolutionsLimited
LTMotorsDivision
Ahmednagar
0.5 HP / 4 POLE (0.37 KW / 4 POLE) MOTOR DATASHEET
xxv Vibration As per IS:12075
a Velocity mm/s
b Displacement microns
xxvi Noise level db(A) at 1 m at no load As Per IS:12065
3 CONSTRUCTIONAL FEATURES
i Stator winding insulation
a Class & type F (Temp. rise limited to class B)
b Tropicalised (yes/no) Yes
c Temperature rise over specificed max.
i. cold water temp. of 38 deg. C N.A.
ii. Ambient air 50 deg. C. 70
d Method of temperature measurement by resistance
e Stator winding connection Star
f Number of terminals braught out 6
ii Type of terminal box for
a Stator leads Cast iron non phase seggregated
b space heater Non phase seggregated
c Temperature detectors N.A.
d instrument switch etc. N.A.
iii. For main terminal box
a Location RHS From DE
b Entry of cables Side
c Recommended cable size 0
(to be matched with cable size
envisaged by owner)
d Fault level 50kA for 0.25 sec
iv Temperature detector for stator winding No
a Type NA
b Nos. provided NA
c Location NA
d make NA
e resistance value at 0 deg. C (ohms) NA
v space heaters Yes
a Number N.A
b Location Winding overhang
c Power requirement (watt) N.A
vi Paint shade RAL5021 WAT BLUE
vii Weight of
a Motor stator 5
b Motor rotor 3
c Total weight (kg) 8
4 CHARACTERISTIC CURVES
i Torque speed characteristic of the motor Yes
ii Calibration characteristic of platinum N.A.
type resistance temperature detector
iii Calibration characteristic of platinum N.A
BTD
iv Thermal withstand characteristic Yes
v starting current vs. time Yes
vi starting current vs. speed yes
vii neg. sequence current vs. time N.A.
viii PF & efficiency V.s load. Yes
10000
WITHSTAND TIME ( SEC.)
1000
THERMAL W
100
28
25
16
13
10 14 13
8
7
1
0 100 200 300 400 500
STARTING CURRENT ( % FLC )
SPEED VS TORQUE
280
240
200
160
LOAD TORQUE
120
% FULL L
80
40
FAN
0
0 10 20 30 40 50 60 70 80 90 100
% SYNCHRONOUS SPEED
LOAD Vs EFFICIENCY
90
80 77.3 77.3
74
70
60
EFFICIENCY (%)
50
40
30
20
10
0
NO LOAD 1/4 LOAD 1/2 LOAD 3/4 LOAD FULL LOAD
LOAD
LOAD Vs POWER-FACTOR
0.7 0.66
0.6
0.6
0.5
0.5
FACTOR
POWER
0.4
0.3
0.2
0.1
0
NO LOAD 1/4 LOAD 1/2 LOAD 3/4 LOAD FULL LOAD
LOAD
SPEED Vs CURRENT
500
300
200
100
0
0 20 40 60 80 100
% SYNCHRONOUS SPEED
AT 110% V AT 100%V AT 80% V AT 75% V
TIME Vs CURRENT
500
450
400
350
SCC (%FLC )
300
250
200
150
100
50
0
0 50 100 150 200 250
%STARTING TIME
CGPowerandIndustrialSolutionsLimited
LTMotorsDivision
Ahmednagar
7.5 HP / 4 POLE (5.5 KW / 4 POLE) MOTOR DATASHEET
1 GENERAL
i Manufacturer & country of origin CG Power and Industrial Solutions Limited
ii Equipment driven by motor Tube Axial Fans
iii Motor type 3 PHASE AC SQUIRREL CAGE INDUCTION MOTOR IE3
iv Quantity 01 No. (System: VE-1)
CGPowerandIndustrialSolutionsLimited
LTMotorsDivision
Ahmednagar
7.5 HP / 4 POLE (5.5 KW / 4 POLE) MOTOR DATASHEET
xxv Vibration As per IS:12075
a Velocity mm/s
b Displacement microns
xxvi Noise level db(A) at 1 m at no load As Per IS:12065
3 CONSTRUCTIONAL FEATURES
i Stator winding insulation
a Class & type F (Temp. rise limited to class B)
b Tropicalised (yes/no) Yes
c Temperature rise over specificed max.
i. cold water temp. of 38 deg. C N.A.
ii. Ambient air 50 deg. C. 70
d Method of temperature measurement by resistance
e Stator winding connection Delta
f Number of terminals braught out 6
ii Type of terminal box for
a Stator leads Cast iron non phase seggregated
b space heater Non phase seggregated
c Temperature detectors N.A.
d instrument switch etc. N.A.
iii. For main terminal box
a Location RHS From DE
b Entry of cables Side
c Recommended cable size 1 * 3C,10-MM
(to be matched with cable size
envisaged by owner)
d Fault level 50kA for 0.25 sec
iv Temperature detector for stator winding No
a Type NA
b Nos. provided NA
c Location NA
d make NA
e resistance value at 0 deg. C (ohms) NA
v space heaters Yes
a Number N.A
b Location Winding overhang
c Power requirement (watt) N.A
vi Paint shade RAL5012EPOXY
vii Weight of
a Motor stator 47
b Motor rotor 31
c Total weight (kg) 78
4 CHARACTERISTIC CURVES
i Torque speed characteristic of the motor Yes
ii Calibration characteristic of platinum N.A.
type resistance temperature detector
iii Calibration characteristic of platinum N.A
BTD
iv Thermal withstand characteristic Yes
v starting current vs. time Yes
vi starting current vs. speed yes
vii neg. sequence current vs. time N.A.
viii PF & efficiency V.s load. Yes
10000
WITHSTAND TIME ( SEC.)
1000
THERMAL W
100
28
25
16
13
10 14 13
8
7
1
0 100 200 300 400 500 600 700
STARTING CURRENT ( % FLC )
SPEED VS TORQUE
360
320
280
240
LOAD TORQUE
200
160
% FULL L
120
80
40
FAN
0
0 10 20 30 40 50 60 70 80 90 100
% SYNCHRONOUS SPEED
LOAD Vs EFFICIENCY
100
87.4 89.6 89.6
90
80
70
EFFICIENCY (%)
60
50
40
30
20
10
0
NO LOAD 1/4 LOAD 1/2 LOAD 3/4 LOAD FULL LOAD
LOAD
LOAD Vs POWER-FACTOR
0.9 0.81
0.8 0.76
0.7 0.66
0.6
FACTOR
POWER
0.5
0.4
0.3
0.2
0.1
0
NO LOAD 1/4 LOAD 1/2 LOAD 3/4 LOAD FULL LOAD
LOAD
SPEED Vs CURRENT
700
600
500
SCC (% FLC)
400
300
200
100
0
0 20 40 60 80 100
% SYNCHRONOUS SPEED
AT 110% V AT 100%V AT 80% V AT 75% V
TIME Vs CURRENT
700
600
500
SCC (%FLC )
400
300
200
100
0
0 50 100 150 200 250
%STARTING TIME
NG132S 216 140 89 132.0/131.7 47 255 220 12.0 / 12.5 191 275 490 315 12 78 80
NOTES
ONE EARTHING TERMINAL IS PROVIDED INSIDE MAIN TERMINAL BOX.
MOTOR MAY HAVE ADDITIONAL FOOT HOLES FOR CUSTOMER/SITE FLEXIBILITY
**MINIMUM DISTANCE FOR EFFICIENT COOLING OF MOTOR TO BE MAINTAINED BY USER