Professional Documents
Culture Documents
FEATURES
DIRECTIONAL COUPLER
OUTPUT TEST POINT
OPERATION TO 550 MHz
CONVENTIONAL AND POWER
DOUBLING TECHNOLOGIES
HIGH OUTPUT CAPABILITY
INTERCHANGEABLE ACCESSORIES
AND MODULES
HOUSING & CHASSIS SUPPORT UP
TO 1 GHz BANDWIDTH
INTRODUCTION
The" J" series of line extenders offers both
conventional and power doubling tech-
nologies.
The JLX-Cuses the latest generation of hybrid
push-pull technology for 450 MHz operation.
The JLX-C is intended for use as a typical
feeder line extender. JLX-C has increased gain
for more economical system design and The JLXhousing and chassis have been designed The 30dB test points, accessible through the
includes a highly efficient switch mode power to support operation up to 1 GHzbandwidth. The housing, are built into the line extender for
supply for minimum power consumption. amplifier housing is designed for maximum heat improved accuracy. Standard male "G" to female
The JLX-P line extenders use advanced power dissipation; has a woven wire gasket between "F" adapters are recommended for field readings
doubling hybrid technology to provide body and lid for efficient ground continuity and with standard test equipment.
improved distortion performance at high out- RF shielding; and a silicone rubber gasket for For system operation of 350 MHz or less, an
put levels. These power doubling line exten- weather protection. The input and output ports
optional plug-in slope board, model JLP-SLB-
ders offer high gain performance with low have extrusions for securely interfacing cable 350 is available.
power requirements through the use of a connectors with heat-shrunk tubing.
Optional return amplifier, Model JLX-SSis avail-
highly efficient switching power supply. The amplifier module can be plugged into able and can be plugged into the main module
JLX-* FEATURES the housing in either direction as required to amplify the 5-30 MHzsub-channel band.
by signal flow.
"J" series line extenders support 60V power-
ing at input levels as low as 38 volts. Surge JLX SERIES LINE EXTENDER
arrestors, Model XO-36, come installed in all J
series line extenders.
~ GeneraL Instrument
5-17
Jerrold
STARLINE JLX Series Line Extenders
JLX-1-450C SPECIFICATIONS
Specifications
dB.U/M
-dB
Amps
PARAMETERS
dB
-40 72
63
0.41
0.38
0.37 77
7
16
88
71
8
7+0.45-30
7
16
8
68
0-8
0.64
24
-40
50-45050-450
33
0.75
16
60
38-60
2524 847
0-4
0-8
0.35
14.023.0
to
maximum
28 60 1
6
0.58
-40 6maximum
9
-40
JLX-1-550P
50-550
5-30
40JLX-6-550P
50-550
50-450
0.75
34
38
XO-
35
24
2 5-30
0.75
34
0.75
XO-36
XO-36
33
73
64
65
63
71
60
622
7
38-60
63
0-8 3
0
4
38-60
38-60
0-40-8
0-4
0-4
0.58
0.54
0.49
20.0
0.52
0.46
0.64
0.54
23.0
0.49
0.46
0.58
0.52
0.49
20.0
24 36
4JLX-HSG
JLX-6-450P
29
64 to
dBmVto..
0.4
maximum
to
0.4
JLX-1-450P
JLX-HSG
JLX-HSG
25
2525
dBmV
Optional
Optional
47
47Optional
47 dBmV +++JLX-SS
0.4
maximum
dBmV 60
60
Output60
Output NOTES
JLX-SS
JLX-SS
Output
Output 6 89 MHz
3Amps
74,11
1,2
4,5 -dB
dBVAC
Watts
VDC
mVppdBdB
'C 5-30
XO-36
JLX-HSG
Optional JLX-SS
Forward
Gain
@ 60
Input
DC VAC
Range
Voltage
NOTES:
1. Line Extender Electronics, Power Supply and Housing. Order Equalizers (EQ-*-*), 6. Measured with C.W. carriers and spectrum analyzer.
Thermal Gain Compensation (CTF-Jl.X), Pads (JXP-*), and Return Amplifier 7. Any combination of channels.
(Jl.X-SS), Diplex Filters (DF1-*) and Response Correction (RCB-SS) separately. 8. From 60 Hz source, at 7 amps.
2. Models Jl.X-450P & Jl.X-550P are referenced to standard product with 450 & g. 7 amp referenced for use with 7 amp fuse (CFJ-7A). 5 amp capable with use of 5
550 MHz slope boards (respectively) included. amp Circuit Breaker (CBJ-5).
3. At highest channel without Equalizer (EQ-*-*) or Thermal Gain Compensation 10. See Diplex Filter specifications for chroma delay.
(CTF-Jl.X). Gain control range set for maximum unit gain. 11. For two-way operation with Diplex Filters (DF1-*) and Response Correction (RCB-
4. At 450 MHz with 9 dB slope (50 to 450 MHz). At 550 MHz, with 10 dB slope. With *), typical operating gain is reduced by .5 dB.
Equalizer (EQ-*-*). Thermal Gain Compensation (CTF-Jl.X). Gain control set for max-
imum unit gain.
5. Standard Channel assignments per NCTAtest methods.
In U.S.: Hatboro. PA 19040 (215) 674-4800. In Canada: Toronto. ant. (416) 789-7831. In Europe: Reading. EngLand44-734-755555. In Hong Kong: 852-587-1163. In BraziL: 55-21-494-3132. In Argentina: 541-788-4567.
1994 GENERALINSTRUMENT
5-18