You are on page 1of 2

Varian CP-4900 GC

Micro-GC
Simple, reliable, and
cost-effective gas
analysis wherever
you need it!

Separations in seconds When the composition of gas User exchangeable GC channels


mixtures is critical, Varians CP-4900 provide quick and easy reconfigura-
Analysis anywhere Micro-GC delivers the information tion or repair.
Easily exchangeable GC you need time after time. Our 4th
generation micro-GC generates more Increase Monitoring Frequency
channels data in less time for faster and Micro-electronic gas control with
better business decisions. time-programmable backflush lets
you inject samples while eliminating
The Speed You Need
contaminants. Fast analysis and
Precise gas analysis in seconds rather frequent process monitoring with the
than minutes brings improved CP-4900 ensures high quality end
product quality and more exact products.
product valuation to industries such
as oil and gas exploration, refining, Immediate Start-Up
natural gas production and On arrival, the CP-4900 provides the
distribution, fuel cell development, results and ruggedness you demand
and specialty gas production. in the lab and in the field for the
analysis of gas and vapor streams.
On the Road with the CP-4900
The CP-4900 is a rugged, compact Start-up is immediate with electronic
analyzer for lab-quality gas analysis data sheets (EDS) which store
at any site. operational history and the last used
method for each GC channel. The
With advanced micro-machining and CP-4900 can be controlled from
computing technologies, the virtually anywhere in the world
CP-4900 offers one to four plug- through a PC and the internet using
and-play GC channels. Each channel industry standard protocols.
is a separate GC with pneumatics,
injector, column, and detector.
Micro-GC
CP-4900 GC Specifications Repeatability: < 0.5% RSD for Communication
propane at 1 mol % level for WCOT Analog input: 6 signals
Configuration: one to four plug- columns at constant temperature
and-play GC channels and pressure
External port: RS-232
Optional: Ethernet TCP/IP with
Control: independent control for Carrier Gas static IP address
each channel with its separate He, H , N or Ar: 550 10 kPa
2 2 Optional: Com Port for external
pneumatics, injector, column, and
(80 1.5 psig) input devices, selectable RS-232 or
detector
Inlet connection: 3.2 mm (1/8 in.) RS-485
Injector stainless steel compression fitting
(Swagelok) Control/Data Handling Software
Micro-machined injector with no
Standard packages: Star
moving parts
Sampling Chromatography Workstation or
Injection volume: 1 L to 10 L, Sample inlet: 1.6 mm (1/16 in.) CP Matre-Elite
software selectable stainless steel Valco fitting with Regulatory compliance and
Optional heated injector: 30 C to replaceable 5 m stainless steel reports: meet requirements,
110 C, including heated transfer filter particularly for the natural gas
line Sample conditions: non- and petrochemical industries
condensing gas of 0 C to 40 C Special packages: ISOCAL and BTU
Column Oven
Maximum sample input pressure: for natural gas properties, such as
Temperature range: 30 C to 200 kPa (29 psig) calorific value and relative density,
180 C, isothermal meet ISO 6976, GPA 2171, and
Optional separate sample inlet in
Optional backflush capability ASTM D 3588 standards
front or back

Detector Optional Field Case


Environmental Requirements
Micro-machined Thermal Humidity (relative): 0% to 95% Gas containers: one or two 300 mL
Conductivity Detector (TCD) non-condensing gas containers with maximum
Dual-channel (sample and Temperature: 0 C to 50 C pressure of 12,000 kPa (1740 psig)
reference) Rechargeable battery packs: two
Internal volume: 200 nL per Dimensions and Weight Two-channel system: 37 cm (h) x
channel 29 cm (w) x 41 cm (d)
Two-channel system: 28 cm (h) x
Filaments: 4 15 cm (w) x 30 cm (d) Four-channel system: 37 cm (h) x
Four-channel system: 28 cm (h) x 29 cm (w) x 72 cm (d)
Detection Limits
15 cm (w) x 55 cm (d) Weight with CP-4900: minimum
WCOT columns: 1 ppm of 16 kg
Weight: minimum of 5.2 kg
Micro-packed columns: 10 ppm
Power Requirements Optional Micro-Gasifier
Operating Range Main power: 90-130 Vac or Heated pressure reducing regulator
Concentration: 1 ppm to 100% 180-260 Vac, 50-60 Hz Injection of high pressure LPG or
level Output: 12 Vdc, maximum 180W LNG samples
Linear dynamic range: 106

Varian, Inc. www.varianinc.com


North America 800.926.3000, 925.939.2400
Europe The Netherlands: 31.118.67.1000
Asia Pacific Australia: 613.9560.7133
Latin America Brazil: 55.11.3845.0444
Other sales offices and dealers throughout the world

GC GC/MS HPLC AAS ICP ICP-MS UV-Vis-NIR Fluorescence Dissolution NMR Analytical Supplies

P503515

You might also like