1.0 OBJECTIVE

2.0 SCOPE

SURFACE PREPARATION
3.0

4.0 COATING SYSTEMS

5.0 APPLICATION

2|Page
DATE 04.07.2017

PAINT AND PROTECTIVE COATING PROCEDURE FOR


VALVES

1.0 OBJECTIVE

This procedure is developed to ensure that surface preparation, blast and


paint is carried out in a controlled manner.

2.0 SCOPE

This procedure also describes the activities which enable to paint the valves with
Primary Coat Epoxy Zinc Primer,(STD grey) and finish Coat ,Hard Top AS(Blue).

3.0 SURFACE PREPARATION

After having duly checked that the valves are properly protected at the ends and in
the areas not to be painted, proceed with the blasting.
The surface shall be then blast cleaned to
- Blast profile shall be range of 30 60
microns
- The blast profile has to be controlled by means of a suitable instrument
i.e profile gauge. The blast profile shall be measured and recorded.

- Only dry abrasive blasting product shall be used and it shall be free from
dust, alts and other impurities.
All sharp edges shall be grind rounded smoothly before blasting.

3|Page
DATE 04.07.2017

PAINT AND PROTECTIVE COATING PROCEDURE FOR


VALVES

4.0 COATING SYSTEMS

4.1 Prime coat - Epoxy Zinc Primer(STD grey) - D.F.T 75-90 microns

4.2 Final coat - Hard Top AS( Blue) - D.F.T 65 70 microns

Total DFT: 140 160


microns

5.0 APPLICATION

Coating shall be applied before any visible deterioration occurs and within a
maximum of four (4) hours after surface preparation.

Coating shall not be applied to surfaces whose temperature is 3 deg C above the
dew point and when the relative air humidity exceeds 85%.

Coating shall be applied in a uniform layer by airless


spray.

Coatings shall not be applied to previously coated surface unless the proceeding
coat has dried.

Care shall be paid for coatings edges, corners and areas difficult to coat adequately
by spray. In this case extra coat by brush may be applied immediately before the
overall spray coat.