DISEO TRMICO

Proceso de secado
Contenido de Humedad Inicial xwi := 40 %
Contenido de Humedad Final xwf := 12 %
Temperatura de Secado Tsec := 70 C
Tiempo de Sec ado tsec := 12 Hrs
Producto Morochillo
Masa Humeda mhum := 1000 kg
Calor de reaccin de combustible HR := 12000

Masa Seca
100 xwi
msec := mhum
100
msec = 600 kg

Cantidad de Agua a Remover (W)

W := msec
xwi xwf

100 xwi 100 xwf

W = 318.182 kg

Potencia Trmica de Evaporacin (Pe)


W 25000
Pe :=
tsec 3600

Pe = 184.133 KW

Potencia del Quemador (PQ)


PQ := 2 Pe Seleccionamos 2 por la facilidad de quemar

PQ = 368.266 KW

Consumo de combustible
PQ 3600
mcombustible :=
HR 1
kg
mcombustible = 110.48
hr

mc := mcombustible tsec

mc = 1325.758 kg de biocombustible
Calor de Secado
Tamb := 15 C
Hfg := 540 kcal
kg

Capacidad Calorfica (Cp)


1.675 + 0.025 xwi kcal
Cp :=
4.184 kg C

Cp = 0.639 kcal
kg C
mhum W
Cp ( Tsec Tamb) + Hfg
tsec tsec
Qutil := KW
860

Qutil = 20.056 KW

Dimensionamiento

h = altura
a := 2.44 m
hmorochillo := 0.5 m
kg
morochillo := 780
3
m

mhum
Vcsec :=
morochillo

3
Vcsec = 1.282 m

a b hmorochillo = Vcsec

Vcsec
b :=
a hmorochillo

b = 1.051 m por lo tanto se necesita una


sola plancha

Vcsec
hsec :=
a 1.22

hsec = 0.431 m
1
U=
Rtermicas
n

m
W Vw := 1.8
kax := 17 s
m C

klroc := 0.04 W he := 2.8 + 3 Vw


m C
he = 8.2
kac := 50 W
m C

1
Ui :=
0.004 0.05 0.005 1
+ + +
17 0.04 50 8.2

W
Ui = 0.729
2
m C
Calor perdido a travs de las paredes del secador (Qp1)

Qp1 = Ui A1 T

A1 := 2 ( 1.22 hsec) + 2 ( 2.44 hsec)


2
A1 = 3.153 m

Qp1 := Ui A1 ( Tsec Tamb)

Qp1 = 126.353 W

Calculo del calor perdido por conveccin y radiacin en la parte


superior del secador (Qp2)

Vw2 := 0.5

Conveccin Radiacin
3
ho := 2.8 + 3 Vw2 hr = 4 Tm
W ( 70 + 273 ) + ( 15 + 273 )
ho = 4.3 Tm :=
2 2
m C
Tm = 315.5 K
8
:= 0.7 := 5.67 10
3
hr := 4 Tm

hr = 4.986 W
2
m C

Qp2 = Qconv + Qrad = ho A2 ( Tsec Tamb) + hr A2 ( Tsec tamb)

A2 := 1.22 2.44
2
A2 = 2.977 m

Qp2 := A2 ( Tsec Tamb) ( ho + hr)

Qp2 = 1520.316 W
Calor perdido Total (Qp)

Qp := Qp1 + Qp2

Qp = 1646.669 W
Calor Neto (Qn)

Qp
Qn := Qutil +
1000

Qn = 21.703 KW

INTERCAMBIADOR DE CALOR

Aire impulsado desde el soplador

m
Tci := 25 C Vci := 14 c = cold
s
i = input
m
Tco := 140 C Vco := 8
s o = output
h = hot
Tci + Tco v = velocidad
Tcm := = 82.5 C
2

Vci + Vco m
Vc := = 11
2 s

Propiedades termofsicas (Tcm: 82.5 C= 355.5 K)

kg 6 2
a := 0.981 a := 21.52 10 m
3
m s

3 W Pr := 0.6989
Ka := 30.42 10
m K
Di := 0.0214 m Do := 0.0254 m

Vc Di
Rei :=
a

Rei = 10938.662

Dittus - Boelter

hii Di 0.8 0.4


NuD = = 0.023 Rei Pr
Ka

0.8 0.4
0.023 Rei Pr Ka
hii :=
Di

W
hii = 48.24
2
m C

Calculo del coeficiente de Conveccin externo (ho,i)

m m
Vhi := 8 Vho := 6
s s

Vhi + Vho m
Vh := =7
2 s

x := 2 in y := 2 in D := 1 in

Vh y
Vmax :=
yD

m
Vmax = 14
s
Grimson
y x
=2 =2 Pag. 175 Libro de Pitts
D D

C1 := 0.229 n := 0.632

ho1 D n
= C1( Remax)
kfluido

Thi := 229 C Tho := 56 C

Thi + Tho
Thm := = 142.5 C
2

Propiedades termofisicas (T=125 C : T=415.5 K)


2
6 m 3W
m := 28.26 10 Kfluido := 34.89 10
s m K

Vmax Do
Remax :=
m

Remax = 12583.156
n
C1 ( Remax) Kfluido
ho1 :=
Do

W
ho1 = 122.679
2
m C

Coeficiente Global de Transferencia


Di
hio := hii
Do

W
hio = 40.643
2
m C

hio ho1
U :=
hio + ho1

W
U = 30.529
2
m C

You might also like