GE 200

Version 1.1/1202
GE 200

Manufacturer's Reference:
This equipment fulfils the requirements of the EU standard 89/336/EWG (EN
55022/EN 50082-1).

Therefore this equipment is CE-labelled.


Please keep this description in safe custody !

Application:
With regard to the CE mark, the central is suitable for the following types of application:
residential buildings, office and commercial premises, small businesses and industrial
premises with public low-voltage mains supply.

Caution:
Defective power cables of the transformer shall not be repaired or changed. In case of
defective power cables, the whole transformer must be exchanged.

Mounting and installation of the central and of the equipment may be


carried out by authorised service personnel only.
Cards may be exchanged only while the voltage is switched off.

Always make sure ESD precautions have been taken before exchanging cards.
The - terminal of the motherboard G2-GEM (see page 18) is used as ground-
ing point for Wrist Strap Grounding.

GE 200
Chapter: I:\DOKU\GE200\GE200_E.FM
Version: 1.1/1202
Number of pages: 35
Created: 2002-12-02 Checked: 2002-12-02 Released: 2002-12-02
Roswitha Scherer Roswitha Scherer Georg Winkler

Page 2 of 35 Vers. 1.1/1202


GE 200

Content
Planning Information 5 Installation 17
Range of Application 5 Removing the Cover 17
Expansion 5 LED-Status Indication 17
Extent of Supply 5 Mounting, Cable Run 18
Cable Length 6 Connection Diagram GE 200, GEZ 200, GEI 200 19
Programming cable 7 Connection of Interface Housing GEI 200 20
Mode GE 100/GE 200 (Networking) 7 Connection of Subscriber Cards 21
Subscriber Cards 8 Connection of Intercom Stations 22
Link cards 8 Connection of Input / Output Cards 23
Dynamic Audio Link Control 8 Link card G2-GEK2-3 24
Plug-in positions of the cards 9 Connection of Interface Cards 25
Connection of Network / Connection Cards 29
Setting the System Numbers 33
Technical Data 10
Basic Central GE 200 10
Expansion Central GEZ 200 10 Technical Support 35
Interface Housing GEI 200 10
Subscriber Cards 11
Link card G2-GEK2-3 11
Input / Output Cards 12
Interface cards 13
Network / Connection Cards 15

Vers. 1.1/1202 Page 3 of 35


GE 200

Page 4 of 35 Vers. 1.1/1202


GE 200 Planning Information

Planning Information
The digital intercom central GE 200 combines different functions of modern
internal communication such as intercom, information and control in one
system. By means of subscriber cards with different feature levels and addi-
tional interfaces the central can be adapted to the individual needs with ease.

Range of Application
As office intercom central with all 2-wire and 4-wire intercom stations (with
or without display). As door intercom system with central control functions
and integrated CCTV cameras. As emergency call system with transfer over
telephone lines (e.g. for elevator emergency call stations, parking houses,
officer emergency call etc.). As checkout intercom for supermarkets and
warehouses. As parking areas intercom with emergency call points, barrier
control and linked video cameras. As mini-control desk system for order
preparation and processing in distribution and industry.

Expansion
Basic expansion: Maximum expansion:
Subscribers: 0
Outputs: 2 see Plug-in positions of the
Inputs: 2 cards on page 9

Extent of Supply
GE 200: Basic central including CD Software & Manuals
GEZ 200: Expansion central including short reference
GEI 200: Interface housing including short reference
The types of GE 200 and GEZ 200 differ in extent of supply:
Type: Power supply:
GE 200, GEZ 200 X-PA1-230V Transformer 230 V Europe
GE 200AU, GEZ 200AU X-PA1-230V-A Transformer 230 V Australia
GE 200U, GEZ 200U X-PA1-120V Transformer 120 V USA
GE 200TE, GEZ 200TE - without transformer

Vers. 1.1/1202 Page 5 of 35


Planning Information GE 200

Cable Length
Stations series EE 211, EE 711
Maximum cable length at diameter:
0.5 mm 0.6 mm 0.8 mm
Cable type: Reference: Capacity: 0.019 inch 0.024 inch 0.032 inch
AWG 24 AWG 22 AWG 20
100 nF/km 2000 m 2000 m
F-YAY Installation cable PVC *
30.5 nF/1000 ft 6562 ft 6562 ft
1500 m / 2000 m / 3000 m /
4922 ft 6562 ft 9843 ft
Cat. 5 cable, foamed 45 nF/km
J-02YS(St)Y (3000 m / (3000 m / (3000 m /
polyethylene 13.7 nF/1000 ft
9843 ft with 9843 ft with 9843 ft with
ext. supply) ext. supply) ext. supply)
*...no data, because this diameter is not available for this cable type.

Stations series EE 411


All data about line lengths (series EE 411 with and without display) corre-
spond to a loudspeaker attenuation of approx. 9 dB and a microphone at-
tenuation of approx. 3 dB. 9 dB correspond to approx. 3 volume steps adju-
sted at an EE 411, 3 dB refer to approx. 1 volume step.

Stations with display:


The following cable lengths are valid only with subscriber cards G2-GET-4
with software from version V02.0 and with display stations from revision 03.

Maximum cable length at diameter:


0.5 mm 0.6 mm 0.8 mm
Cable type: Reference: Capacity 0.019 inch 0.024 inch 0.032 inch
AWG 24 AWG 22 AWG 20
J-Y(ST)Y Installation cable PVC 120 nF / km * 750 m 750 m
36.6 nF / 1000 ft 2461 ft 2461 ft
F-YAY Installation cable PVC 100 nF / km * 900 m 900 m
30.5 nF / 1000 ft 2953 ft 2953 ft
KC 102/104 Installation cable PVC 65 nF / km 1000 m * *
19.8 nF / 1000 ft 3281 ft
F-2YA2Y Buried cable polyethylene 55 nF / km * 1500 m 1500 m
16.8 nF / 1000 ft 4922 ft 4922 ft
J-02YS(St)Y Cat. 5 cable, foamed 45 nF / km 1000 m * *
polyethylene 13.7 nF / 1000 ft 3281 ft
*...no data, because this diameter is not available for this cable type.

The maximum line capacity for cables not listed in this table is 90 nF. This
capacity refers to: A against B, C against D, C/D together against A as well
as the single lines A, B, C, D against an eventual shield (ground). This capa-
city can be measured with a multimeter with open end of the line: A against
B, C against D, C/D together against A, A against shield, B against shield, C
against shield and D against shield. All these capacity values may not be hig-
her than 90 nF.

Page 6 of 35 Vers. 1.1/1202


GE 200 Planning Information

Stations without display / power supply stations, amplifiers:

Maximum cable length at given diameter/cross section


0.4mm 0.5mm 0.6mm 0.8mm 1.0mm 1mm2 1.5mm2 2.5mm2
Reference 0.016in 0.019 in 0.024in 0.032in 0.039 in 0.039in2 0.069in2 0.098in2
AWG26 AWG24 AWG22 AWG20 AWG18 AWG18 AWG16 AWG14
Intercom station 650m 1000m 1500m 2600m 4200m * * *
without display 2133 ft 3281 ft 4922 ft 8531 ft 13780ft
Industrial station 1300m 2000m 2700m 4900m 7700m * * *
EE 6000 (A,B,C,D) 4265 ft 6562 ft 8859 ft 16077ft 25264ft
Power supply for 45m 70m 100m 180m 280m 360m 540m 900m
EE 6000 (24V~) 148 ft 230 ft 328 ft 591 ft 919 ft 1181 ft 1772 ft 2953 ft
Power supply for 210m 330m 475m 840m 1320m 1680m 2520m 4200m
EE 6000 (60V=) 689 ft 1083 ft 1558 ft 2756 ft 4331 ft 5512 ft 8268 ft 13780ft
Power supply for 15m 23m 33m 58m 90m 115m 170m 280m
KE 510 (24V~) 49 ft 76 ft 108 ft 190 ft 295 ft 377 ft 558 ft 919 ft
Power supply for 8m 12m 17m 29m 45m 58m 65m 140m
KE 520 (24V~) 26 ft 39 ft 56 ft 95 ft 148 ft 190 ft 213 ft 459 ft

Programming cable
For programming of the GE 200 a 9-way D-Submin elongation cable is re-
quired (1:1, plug on central side, socket on PC side):

NC 1 1
TXD 2 2
RXD 3 3
NC 4 4
GND 5 5
NC 6 6
NC 7 7
NC 8 8
NC 9 9
GE 200 (9-way D-Submin plug) (9-way D-submin jack) PC
NC = not connected

This cable can be purchased at an electric outfitter or ordered under the type
X-KAB-CCT.

Mode GE 100/GE 200 (Networking)


The GE 200 can be operated in two modes:
GE 100 mode (no system number adjusted): The central can be operated
only as single central, not in a network. In this mode the calling numbers
are assigned two digits as standard. Network cards (e.g. G2-S0-I) are not
recognised by the central.
GE 200 mode: A system number is adjusted with the DIP switches or with
the program TE 700 (see Setting the System Numbers on page 33). If
several centrals GE 200/GE 700 shall be connected to a network (e.g. via
S0, CNET-W or CNET-E1), each central must have a unique system num-
ber. In this mode the calling numbers are assigned three digits as stan-
dard.

Vers. 1.1/1202 Page 7 of 35


Planning Information GE 200

Subscriber Cards
All station specific functions are handled by the subscriber cards. The subs-
criber cards are available in different feature levels: B, C and D. The cards of
the higher levels contain all the features of the lower ones plus additional
features. An overview of the features can be found in the manual Fea-
tures.
The subscriber cards can be mixed in the central as desired. In case of a con-
versation between subscriber cards of different levels only the features of
the subscriber card with the lower level are available.
All subscriber cards are equipped with plugable terminals.
Attention: As soon as 4-wire subscribers are used a link card G2-GEK2-3
is required. If only 2-wire subscribers are used, link cards are
not required. See also Link cards on page 8.

Link cards
A link card is required for two reasons:
1. If a GE 200 (GEZ 200) contains 4-wire subscriber cards, one link card G2-
GEK2-3 is necessary.
2. If features like Reception of several music programs, Conference or
Radio conference are used, additional link cards G2-GEK2-3 are requi-
red (for music 4T1 no link card is required, feeding via music input).
Available per link card G2-GEK2-3 (a maximum of 3 G2-GEK2-3 in one
GE 200 with GEZ 200):
2 duplex controllers (only two duplex controllers can be used in the central,
that means, from more than one cards only the A/D converters can be used).
3 A/D-D/A converters (a maximum of 9 A/D converters can be used)
If only 2-wire subscribers are used, no link card is required.
Available in the GE 200 (including GEZ 200)
48 digital audio lines
12 analogue audio lines
The different types of conversation require a different number of audio li-
nes, the free lines are allocated dynamically (see Dynamic Audio Link Con-
trol on page 8).

Dynamic Audio Link Control


A/D converter Duplex Digital Analogue max. conversa-
controller audio lines audio lines tions (incl GEZ)
Simplex - - 1 - 16
Digital - Digital Switched Duplex - - 2 - 16
Open Duplex - - 2 - 16
Simplex 1 - 1 1 9
Analog - Digital Switched Duplex 1 1 2 4 2
Open Duplex 1 - 2 2 6
Simplex - - - 1 12
Analog - Analog Switched Duplex - 1 - 4 2
Open Duplex - - - 2 6
via G2-GET-4D 1 per channel - 1 1 ** 8 channels
Feed-in of audio
via G2-GED-4D and ET 808, 7 kHz - - 1 - ** 10 channels
signals*
via G2-GED-4D and ET 808, 3.5 kHz - - 1/2 - ** 20 channels
* Features like Reception of several music programs, Conference or Radio conference
For music 4T1 no link card is required, feeding via music input
**restricted by software

Page 8 of 35 Vers. 1.1/1202


GE 200 Planning Information

Plug-in positions of the cards


GE 200 GEZ 200 GEI 200 Maximum number of cards
max. per max. per max. per
A 1 2 3 4 B 5 6 7 8 9 10
GE 200 GEZ 200 GEI 200
G2-GET-4B, C, D - 9 9 9 9 - 9 9 9 9 - - 4 4 -
G2-GED-4B, C, D - 9 9 9 9 - 9 9 9 9 - - 4 4 -
G2-8E8A 9 9 9 9 9 9 9 9 9 9 - - -
together together
G2-16A 9 9 9 9 9 9 9 9 9 9 - - -
2 2
G2-16E 9 9 9 9 9 9 9 9 9 9 - - -
G2-TEL 9 9 9 9 9 9 9 9 9 9 - - 1 1 -
G7-TEL * - - - - - - - - - - 9 9 - - 1*
G2-GEK2-3 9 9 9 9 9 9 9 9 9 9 - - together 3 -
G2-V24 ** 9 - - - - 9 - - - - - - 1 ** 1 ** -
G7-V24-PRO ** - - - - - - - - - - 9 9 - - 2 **
G7-SELCALL *** - - - - - - - - - - 9 9 - - 1 ***
G2-GEL 9 9 9 9 9 9 9 9 9 9 - - 2 2 -
G7-CNET-W - - - - - - - - - - 9 9 - - 2
G7-CNET-E1 - - - - - - - - - - 9 9 - - 2
G2-S0-I **** - - - - - - - - - - 9 9 - - 2 ****
* In this case only one G2-TEL may be used.
** all together a maximum of G2-V24 and G7-V24-PRO can be used (e.g. 1 G2-V24 and 1 G7-V24-PRO)
*** the second slot of the GEI 200 is occupied by the G7-V24-PRO delivered with the G7-SELCALL
**** Two G2-S0-I can only be used in a special system configuration, see manual G7-S0, G2-S0-I.

Vers. 1.1/1202 Page 9 of 35


Technical Data GE 200

Technical Data

Basic Central GE 200


AC power supply: 24 V +/-5% / 40 VA/16 subscribers
DC power supply: 24 - 35 V/40 W/16 subscribers
Emergency power consumption: 200 mAh/h (without cards), cards see techn. data of the cards
Power consumption: - minimum (no conversation): 8 VA, - maximum (all call): 40 VA
Frequency range: analogue: internal 300 - 16000 Hz, digital: 200 - 7000 Hz
Distortion: less than 0.9%
Operating temperature range: 0 C to +50 C (32 F to 122 F)
Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Measurements of the housing: 310 x 210 x 77.5 mm (12.21 x 8.27 x 3.05 inch)
Weight including package: 2210 g (4.87 lbs)
Mounting: Wall mounting
Relay outputs: max. switching capacity: 60 W / 125 VA; max. switching current: 2A;
max. switching voltage: 60 VDC / 40 VAC
Music input: max. 800 mV at 600 Ohm
Inputs IN1, IN2: for floating contacts, max. line resistance: 1.5 kOhm

Expansion Central GEZ 200


Expansion housing for a central GE 200, including power supply (GEZ 200TE
without power supply), for expanding from 17 to 32 subscribers or for addi-
tional interface cards.

AC power supply: 24 V/40 VA/16 subscribers


DC power supply: 24 - 35 V/40 W/16 subscribers
Emergency power consumption: 30 mAh/h (without cards)
Power consumption: - minimum (no conversation): 8 VA, - maximum (all call): 40 VA
Operating temperature range: 0 C to +50 C (32 F to 122 F)
Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Measurements of the housing: 310 x 210 x 77.5 mm (12.21 x 8.27 x 3.05 inch)
Weight including package: 2160 g (4.76 lbs)
Mounting: Wall mounting

Interface Housing GEI 200


Interface housing for two plug-in cards in Euro format.

Power supply: from the central


Emergency power consumption: no power consmption without cards
Operating temperature range: 0 C to +50 C (32 F to 122 F)
Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Measurements of the housing: 310 x 210 x 77.5 mm (12.21 x 8.27 x 3.05 inch)
Weight including package: 1077 g (2.37 lbs)
Mounting: Wall mounting

Page 10 of 35 Vers. 1.1/1202


GE 200 Technical Data

Subscriber Cards
4-wire subscriber card G2-GET-4
Four 4-wire stations can be connected to a G2-GET-4 subscribercard. The
G2-GET-4 is available in feature levels B, C and D.

Data transfer: 4 kBit bi-directional


Maximum output power: 2W
Emergency power consumption: minimum: 70 mAh/h (idle), maximum: 280 mAh/h (all call)
Power consumption intercom station: 0.5 W
Maximum load: 16 Ohm
Wiring: 4-way star feed, twisted pair
Microphone input: Balanced, only for microphone pre-amplifiers of our program
1 subscriber can be switched to 0dBm (0.775V/600 Ohm)
Weight including package: 198 g (0.44 lbs)

2-wire subscriber card G2-GED-4


To a subscriber card G2-GED-4 four 2-wire stations can be connected. The
G2-GED-4 is available in feature levels B, C and D.

Emergency power consumption: minimum: 90 mAh/h (idle), maximum: 280 mAh/h (all call)
Wiring: 2 wires (1 pair) per subscriber
Weight including package: 188 g (0.41 lbs)

Link card G2-GEK2-3


Link card with 2 duplex controllers (speech links), 3 AD/DA converters and
signal-LEDs for status and diagnosis. A description, in which case link cards
are necessary, can be found at Link cards on page 8.
Operating temperature range: 0 C to +50 C (32 F to 122 F)
Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Power supply: from central
Emergency power consumption: 60 mAh/h
Measurements: 60 x 160 mm (2.36 x 6.3 inch)
Weight including package: 135 g (0.3 lbs)

Vers. 1.1/1202 Page 11 of 35


Technical Data GE 200

Input / Output Cards


Input / Output Card G2-8E8A
Plug-in card with 8 inputs for floating contacts and 8 outputs (the outputs
can be arranged as make contact, open contact or change over contact). The
card is equipped with plugable terminals.

Emergency power consumption: minimum: 10 mAh/h (idle), maximum: 170 mAh/h


(all relays and inputs active)
Weight including package: 182 g (0.4 lbs)

Output Card G2-16A


Plug-in card with 16 outputs, of which 4 can be arranged as make contact,
open contact or change over contact and 12 can be connected as make con-
tact. The card is equipped with plugable terminals.

Emergency power consumption: min.: 10 mAh/h (idle), max.: 250 mAh/h (all relays active)
Weight including package: 204 g (0.45 lbs)

Input Card G2-16E


Plug-in card with 16 inputs for floating contacts. The card is equipped with
plugable terminals.

Emergency power consumption: minimum: 10 mAh/h (idle), maximum: 70 mAh/h (all inputs active)
Weight including package: 146 g (0.32 lbs)

Technical Data Outputs:


Implementation: Floating relay contacts
Maximum switching power: 60 W / 125 VA
Maximum switching current: 2A
Maximum switching voltage: 60 VDC / 40 VAC

Technical Data Inputs:


Implementation: for floating relay contacts
Max. line resistance: 600 Ohm

Operating States Inputs


Each input is able to recognize 5 operating states :
Idle position
Active 1
Active 2
Short circuit
Line break

Attention: No voltage may be connected to the inputs. Only FLOATING


CONTACTS like e.g. relay contacts, contactors, keys or swit-
ches may be connected.

Page 12 of 35 Vers. 1.1/1202


GE 200 Technical Data

Interface cards
V24-Card G2-V24
RS 232/RS 422 card with two RS 232-interfaces, of which one can be confi-
gured as RS 422.

Operating temperature range: 0 C to +50 C (32 F to 122 F)


Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Power supply: from central
Emergency power consumption: 30 mAh/h
Baudrate: 300 - 19200 Baud
Wordlength / parity / stopbits: 7-8 / E, O, N /1-2
Protocols: PC02-protocol, other protocols can be loaded via central
RS 422 interface: not isolated from the system
Weight including package: 149 g (0.33 lbs)

Telephone interface G2-TEL


The analogue Telephone Interface G2-TEL can be used for the following
functions: Auto Dialler Mode, PABX Mode or Pager Mode. The three
functions cannot be combined.

General
Operating temperature range: 0 C to +50 C (32 F to 122 F)
Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Plug: Card: 40-way socket strip,
telephone connection: RJ 11
Power supply: from central
Emergency power consumption: 0.1 Ah/h
Measurements: 60 x 160 mm (2.4 x 6.3 inch)
Weight including package: 344 g (0.76 lbs)
Telephone
Dialling method: DTMF
Speech storage capacity: 100 messages, 800 seconds in total
Hardware specifications: according to CTR 21 and EG 201121

Vers. 1.1/1202 Page 13 of 35


Technical Data GE 200

Programmable V24-Card G7-V24-PRO


Programmable V24-card with two RS 232-interfaces, of which one can be
configured as RS 422. Attention: The card works with separately available
driver software only! Own drivers can be programmed with the separately
available developer kit SDK-V24.
The G7-V24-PRO is a plug-in card in Euro format, hence an interface housing
GEI 200 is required.

Operating temperature range: 0 C to +50 C (32 F to 122 F)


Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Power supply: from central
Emergency power consumption: 35 mAh/h
Baudrate: 300 - 19200 Baud
Wordlength / parity / stopbits: 7-8 / E, O, N /1-2
Protocols: programmable with developer kit SDK-V24
RS 422 interface: isolated from the system
Weight including package: 250 g (0.55 lbs)

Radio Interface G7-SELCALL


Radio interface (plug-in card in Euro card format, therefore an interface
housing GEI 200 is required. Both slots of the GEI 200 are occupied by the
G7-SELCALL and the enclosed G7-V24-PRO!)

Operating temperature range: 0 C to +50 C (32 F to 122 F)


Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Power supply: from central
Emergency power consumption: 140 mAh/h
Calling system: ZVEI (CCIR on request)
Repeat-tone coding and decoding automatic
Senders band width: +/- 1 %
Receivers band width: +/- 2 %
Decoding time: 70mS +/- 10ms with ZVEI-standard, 100ms +/- 10ms with CCIR-standard
Decoding sensitivity: higher than 30 % of the standard frequency deviation
Reset time after decoding: 150 mS
Weight including package: 1010 g (2.23 lbs)

Page 14 of 35 Vers. 1.1/1202


GE 200 Technical Data

Network / Connection Cards


Tieline-Card G2-GEL
To each Tieline card G2-GEL one tieline link can be connected, optional 2-
wire or 4-wire.

General
Operating temperature range: 0 C to +50 C (32 F to 122 F)
Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Plug: Card: 40-way socket strip, Tieline: plugable screw terminals
Power supply: from central
Emergency power consumption: 0.1 Ah/h
Measurements: 60 x 160 mm (2.36 x 6.3 inch)
Weight including package: 167 g (0.37 lbs)

Transmission
Data transmission: DTMF
Cabling: 2-wire / 4-wire

Signalling
DTMF-level: -8 dBm +/- 2 dB
Signalling time / break: 48 ms / 20 ms
Speech level: max. -6 dBm

Line Data
Line loss: max. 12 dB (840 Hz)

Electrical Data
Line loss correction: 4 steps (0, +3, +6, +9 dB at 1 kHz)
Hybrid adjust for 2-wire lines: automatic
Frequency range: 300 - 3400 Hz
Return loss (600 Ohm): >= 14 dB
Earth balance: >80 dB
Galvanic separation to the line: by transformer
Nominal impedance: 600 Ohm

ISDN network card G2-S0-I


With the network card G2-S0-I up to 16 central housings GE 200/GE 700 can
be connected via ISDN with dial up connection.
The G2-S0-I is a plug-in card in Euro format, hence an interface housing GEI
200 is required.

Operating temperature range: 0 C to +50 C (32 F to 122 F)


Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Plug: Card: 96-way pc board connector according DIN 41612,
S0 connection: RJ 45
Power supply: from central
Emergency power consumption: 0.1 Ah/h
Measurements: 100 x 167 mm (3.93 x 6.58 inch)
Weight including package: 310 g (0.68 lbs)
Number of conversations between two centrals: 1 per G2-S0-I

Vers. 1.1/1202 Page 15 of 35


Technical Data GE 200

2-wire network card G7-CNET-W


The network card G7-CNET-W allows connection of up to 100 centrals
GE 200/GE 700 via 2 wires with max. 4 km / 2.48 miles line length. All fea-
tures are available across the network, the entire network can be program-
med over one central housing.
The G7-CNET-W is a plug-in card in Euro format, hence an interface housing
GEI 200 is required.

Operating temperature range: 0 C to +50 C (32 F to 122 F)


Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Plug: Card: 96-way pc board connector according DIN 41612,
2-wire connection: screw terminals
Power supply: from central
Emergency power consumption: 0.1 Ah/h
Measurements: 100 x 167 mm (3.94 x 6.58 inch)
Weight including package: 373 g (0.82 lbs)
Number of conversations between two GE 700: max. 12 *
Cable length between two GE 700: max. 4 km (2.48 miles)*
V24-transmission: sync. up to 4800 bit/s, async. up to 115200 bit/s,
full duplex, transparent
HDSL connection: 2-wire, poles switchable; 2B1Q encoding 528 - 2320 kBit/s

* The maximum number of conversations possible depends on the line


length - see manual G7-CNET-W.

E1 network card G7-CNET-E1


The network card G7-CNET-E1 allows connection of up to 100 centrals
GE 200/GE 700 over multiplexer connections or media converter, e.g. fibre
optic. All features are available across the network, the entire network can
be programmed over one central housing.
The G7-CNET-E1 is a plug-in card in Euro format, hence an interface housing
GEI 200 is required.

Operating temperature range: 0 C to +50 C (32 F to 122 F)


Storage temperature range: -30 C to +60 C (-22 F to 140 F)
Relative humidity: 20% to 80%
Plug: card: 96-way pc board connector according DIN 41612
E1: RJ 45 (NT, can be switched to TE) or screw terminals
Connection GEV-ring: 2 x RJ 45
Power supply: from central
Emergency power consumption: 0.05 Ah/h
Number of conversations between two centrals: max. 10
Cabling: 4 wires (2 x RX / 2 x TX)
Cable length: max. 250 m (820 ft) Kat 5,
max. attenuation: 8 dB at 1024 kHz
impedance: 120 Ohm
Protocol: own protocol + CRC4 (G.704, G.706, G.732)
Data rate: 2.048 MBit/s / HDB3 (G.703)
Measurements: 100 x 167 mm (3.94 x 6.58 inch)
Weight including package: 373 g (0.82 lbs)

Page 16 of 35 Vers. 1.1/1202


GE 200 Installation

Installation

Removing the Cover


Press here to
remove the cover

LED-Status Indication
LED is blinking in a one second rhythm: the central is working correctly.
LED blinking fast: during initialization.
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: reset or hardware fault.
LED blinking in rhythm definition error ( ):
at least one wrong or missing plug-in card.

The LED of the expansion central GEZ 200 is switched on permanently, and
is not used as status indication, only as indication for the connected power
supply.
The GEZ 200 has no own ON/OFF-switch, it is switched with the ON/OFF
switch of the basic central GE 200.

Vers. 1.1/1202 Page 17 of 35


Installation GE 200

Mounting, Cable Run

306 mm (12.1 inch)


290 mm (11.4 inch)

GEI 200
max. 120 mm (4.7 inch)

180 mm (7.1 inch)

206 mm (8.1 inch)


GEZ 200
Expansion
Central

max. 120 mm (4.7 inch) 110 cm


(4.3 inch)

Grounding
point for
GE 200 wrist strap
grounding
+30V

A
B
C
D

Cable bearer

4
/ 110 cm
4
/
(4.3 inch)

/2
RJ11-Socket

24VAC

Page 18 of 35 Vers. 1.1/1202


GE 200 Installation

Connection Diagram GE 200, GEZ 200, GEI 200

GEI 200
Slot 9 Slot 10

GEI 200 Slot number


GEZ 200 B 5 6 7 8
GEI 200

Expansion plug Interface slot (e.g. G2-GEK2-3)

e.g. G2-GET-4

e.g. G2-GET-4

e.g. G2-GET-4

e.g. G2-GET-4
30VDC
+
-
output
max. 100mA
+30V
-
+ 30VDC

!
24 VAC
24 VAC
No subscriber cards in supply
the interface slots (A,B) 50 60 70 80

51 61 71 81

52 62 72 82

53 63 73 83

Subscriber numbers
with standard program

GEZ 200 Slot number Power


GE 200 (or A 1 2 3 4
ON
GEI 200)
OFF
Music /
Expansion plug
Interface slot (e.g. G2-GEK2-3)
e.g. G2-GED-4

e.g. G2-GET-4

e.g. G2-GET-4

e.g. G2-GET-4

Alarm
Status-
input Programming LED 30VDC
plug +
- output
+30V
max. 100mA
-
24 VAC + 30VDC
24 VAC
Floating supply
contacts MU- 20 30 40
SIC
IN1
21 31 41
IN2
10
S1 11 22 32 42
12
S2 23 33 43
13
12 34

Subscriber numbers
with standard program
DIP switches
e.g.: A A
Door opener B B
A C
Power supply B D

Attention: When using plug-in cards G2-GET-4, G2-8E8A, G2-GEL and G2-
V24, four pins of the plug in the GE 200 or GEZ 200 remain unused.

Vers. 1.1/1202 Page 19 of 35


Installation GE 200

Connection of Interface Housing GEI 200


For plug-in cards in Euro format an interface housing GEI 200 is required
(one GEI 200 per GE 200 central, the GEI 200 offers place for two interface
cards). The interface housing GEI 200 is connected to the expansion plug of
the GE 200, or, if an expansion housing GEZ 200 is connected there, to the
expansion plug of the GEZ 200 (see Connection Diagram GE 200, GEZ 200,
GEI 200 on page 19).

Remove the plugin / unhinge lever of the plug-in cards


1. Press in the pin at one side with a flat tool (e.g. with pliers).
2. Pull out the pin with the pliers from the other side.

Mount the plug-in cards and installation boards

Installation boards Tool for removing


of installation
boards

1st: plug in

2nd: lock
Plug-in cards

Page 20 of 35 Vers. 1.1/1202


GE 200 Installation

Connection of Subscriber Cards


4-wire subscriber card G2-GET-4

Status subscriber card


Switch for 0 dBm-input:
Subscriber 1 normal
intercom

Subscriber 1
Subscriber 2
Subscriber 3
Subscriber 4
Subscriber 1 for
feed in of AF

Sub.1 Sub.2 Sub.3 Sub.4


ABCD ABCDA BCD ABCD

Status LEDs

2-wire subscriber card G2-GED-4


Status subscriber card
Subscriber 1
Subscriber 2
Subscriber 3
Subscriber 4

Subscriber 1
Subscriber 2
Subscriber 3
Subscriber 4

A BAB ABAB

Status LEDs

Vers. 1.1/1202 Page 21 of 35


Installation GE 200

LED-Status Indication G2-GET-4, G2-GED-4


Status Subscriber Card:
LED is blinking in a one second rhythm: the card is working correctly
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor (du-
ring initialization).
LED blinking in rhythm definition error ( ):
wrong type of subscriber card.
Status Subscriber:
LED on: a working intercom station is connected
LED off: no intercom station connected
LED blinking: line fault
LED flickers: during data transmission

Connection of Intercom Stations


Intercom stations series EE 400, EE 411
Attention: Intercom stations without microphone pre-amplifier (e.g. but-
ton modules ET 566, ET 567 or external buttons for dialling
simulation) have to be equipped with a resistor of 150 kOhm
between A and B and another resistor of 150 kOhm between A
and C.

Modular socket 6/6

- C A B D-
12 3 4 56
Plug RJ 11 6/4
DBAC

Intercom stations series EE 211, EE 711


Plug RJ 11 6/4
2
/

A B

Optional: external supply


for greater line length
Modular socket 6/6
Plug in transformer
8-24 V AC or
1 10-35 V DC
2
3 A Central G2-GED-4
4 B
5 Attention: for connection of an
6
external speaker a 6-way intercom
Amplifier connection cable is required
(Type: X-ASKERJ11)!
External loudspeaker

Page 22 of 35 Vers. 1.1/1202


GE 200 Installation

Connection of Input / Output Cards


Attention: No voltage may be connected to the inputs. Only FLOATING
CONTACTS like e.g. relay contacts, contactors, keys or swit-
ches may be connected.

Input / Output card G2-8E8A


Required firmware G2-8E8A: Version 2.0
Status indication Status LEDs
8E8A card for S1 to S8

S1W

S2W

S3W

S4W

S5W

S6W

S7W

S8W
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8

S1

S2

S3

S4

S5

S6

7S

S8
S1
S2
S3
S4
S5
S6
S7
S8
1
2
3
4
Input 1-8 5
6
7
8

Output card G2-16A

Input card G2-16E

Vers. 1.1/1202 Page 23 of 35


Installation GE 200

LED-Status Indication Input/Output cards


Status Input/Output Card:
LED is blinking in a one second rhythm: the card is working correctly
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor (du-
ring initialization).
LED blinking fast: card inserted in wrong slot.

Status Outputs (only G2-8E8A and G2-16A):


LED on: output closed
LED off: output open

Status Inputs (only G2-16E):


LED on: input active
LED off: input inactive

Link card G2-GEK2-3


Link card with 2 duplex controllers (for two speech links) and 3 AD/DA con-
verters. The G2-GEK2-3 is activated as soon as it is plugged into the central.

2nd A/D converter


3rd A/D converter
1st A/D converter
2nd speech link
1st speech link
Link card
Status-LEDs:

RUN LK1 LK2 CV1 CV2 CV3

LED-Status Indication
Status link card:
LED is blinking in a one second rhythm: the card is working correctly
LED is permanently off: no power, reset or hardware fault
LED is permanently on: waiting for connection to the main processor, du-
ring initialization.
LED blinking fast: card inserted in wrong slot.

Status speech link:


LED is off: speech link available
LED is on: speech link in operation for duplex conversation

Status A/D converter:


LED is off: A/D converter available
LED is on: A/D converter in operation

Page 24 of 35 Vers. 1.1/1202


GE 200 Installation

Connection of Interface Cards


V24 Card G2-V24
Attention: The G2-V24 may only be inserted in slot A or B, otherwise no
cable can be connected.

5 4 3 2 1

9 8 7 6

GND

GND
(Shield)
1....GND

T/R

T/R

T
(Shield)
2....TXD

RX 2nd RS232
TX 2nd RS232
3....RXD
RX 1st RS232
4....NC TX 1st RS232
RS 422
5....GND
V24 card

6....RTS
7....CTS
8....RTS

Status LEDs

RS 232 No. 1 RS 232 No. 2 RS 422


Can be used
instead of
1st RS232

LED-status indication
Status V24-Card:
LED is blinking in a one second rhythm: the card is working correctly
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor (du-
ring initialising).
LED blinking fast: card inserted in wrong slot.

Status RX/TX:
RX-LED on: interface ready to receive
TX-LED on: interface ready to send
LEDs flicker during data transmission

Vers. 1.1/1202 Page 25 of 35


Installation GE 200

Telephone Interface G2-TEL

Telephone line: a b
NC NC NC NC

Status-LEDs:
Run Line

NC = not connected

The plug-in card G2-TEL can be inserted in any slot of the basic central
GE 200 or of the expansion central GEZ 200 and works only with central soft-
ware from Pro 04.7D onwards and with TE 700 4.7D onwards.
Per GE 200 and GEZ 200 one G2-TEL may be inserted (together two).

G7-TEL in a GEI 200


If necessary, a G7-TEL can be used in an interface housing GEI 200, but then
only one G2-TEL may be used in the GE 200/GEZ 200. Software from
Pro 04.5 onwards is required for G7-TEL.
The interface housing GEI 200 is connected to the expansion plug of the
GE 200, or, if an expansion housing GEZ 200 is connected there, to the ex-
pansion plug of the GEZ 200.

Slot 10
(Slot n+1)

GEATEL

Slot 9 G7-TEL
(Slot n)
GEI 200 GEZ 200 GE 200

Page 26 of 35 Vers. 1.1/1202


GE 200 Installation

LED-Status indication
Status Telephone Card (RUN):
LED is blinking in a one second rhythm: the card is working correctly.
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor
(during initialising).
LED blinking fast: card inserted in wrong slot.

Status Line (LINE):


LED is permanently on: onhook.
LED blinking fast: DC on telephone line not available, or download of a
voice file.
LED flickers shortly (once per second) during conversation

Programmable V24-Card G7-V24-PRO


Programmable V24-card with two RS 232-interfaces, of which one can be
configured as RS 422. Attention: The card works with separately available
driver software only! Own drivers can be programmed with the separately
available developer kit SDK-V24.
The G7-V24-PRO is a plug-in card in Euro format, hence an interface housing
GEI 200 is required.

S1
Status-LEDs: S2
RUN RS 232
Rx1 No. 1
Tx1
Rx2
Tx2
ST1
ST2
ST3 RS 232
TINYTIGER No. 2

RS 232
No. 0
RS 422

GEAV 700
RS485 DCF77

LED-status indication
Status V24-Card:
LED is blinking in a one second rhythm: the card is working correctly
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor (du-
ring initialising).
LED blinking fast: card inserted in wrong slot.

Status RX/TX:
RX-LED on: interface ready to receive
TX-LED on: interface ready to send
LEDs flicker during data transmission

ST1, ST2, ST3:


Function of the LEDs depending on the loaded driver software.

Vers. 1.1/1202 Page 27 of 35


Installation GE 200

Radio Interface G7-SELCALL


Radio interface (plug-in card in Euro card format, therefore an interface
housing GEI 200 is required. Both slots of the GEI 200 are occupied by the
G7-SELCALL and the enclosed G7-V24-PRO!)

GEAV 700 GEAK 700

RS 232 no. 1
G2-GET-4D
G7-GET-4D

NC
NC
NC
NC
NC
NC
A
B
C

NC
NC
D

D1

A1
C1
B1
NC

NC
D2
B2

NC
NC
KAB RADIO

IN-
IN+
OUT-

NC
NC
OUT+
Audio

D3

A3
C3
B3
In/Output

A4

D4
C4
B4
Base-station

NC
NC
PTT
PTT

LED-status indication
LEDs on the card G7-SELCALL (without picture, LEDs numered from top to
bottom)

LED 1: Status card G7-SELCALL:


LED is blinking in a one second rhythm: the card is working correctly
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor (du-
ring initialising).
LED blinking fast: card inserted in wrong slot.

LED 2 to 6: Status radio:


LED 2: status PTT (press to talk)
LED 3: no function
LED 4: RxD data transmission to G7-V24-PRO
LED 5: TxD data transmission to G7-V24-PRO
LED 6: no function

Page 28 of 35 Vers. 1.1/1202


GE 200 Installation

Connection of Network / Connection Cards


Tieline Card G2-GEL
To each Tieline card G2-GEL one tieline link can be connected, optional 2-
wire or 4-wire.

Detailed information about start-up and programming can be found in the


manual G1-GEL/G2-GEL/G7-GEL.

Status tieline card

4-wire output
4-wire input
2-wire or
Tieline
ABCD

Status LEDs

LED-Status indication
Status Tieline Card:
LED is blinking in a one second rhythm: the card is working correctly.
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor (du-
ring initialization).
LED blinking fast: card inserted in wrong slot.

Status Tieline:
LED on: Tieline is working
LED off: Tieline not working
LED blinking: line fault
LED flashes during DTMF transmission

Vers. 1.1/1202 Page 29 of 35


Installation GE 200

ISDN Network Card G2-S0-I


For the G2-S0-I (plug-in card in Euro format) an interface housing GEI 200 is
required (see Connection of Interface Housing GEI 200 on page 20).
Detailed information about start-up and programming can be found in the
manual G7-S0, G2-S0-I.
For connection the installation board GEAC 700, which is included in the ex-
tent of supply, must be used:

a
b
S0 Bus 4-wire, max. 150 m ISDN
(max. 492 ft) connection
3 2a a2
100 Ohm
100 Ohm

100 Ohm
100 Ohm
4 1a a1
5 1b b1
6 2b b2
If a twisted pair cable is used,
1a should be twisted with 1b
Socket RJ45 and 2a with 2b NT (NetworkTermination)
4/ max. 10 m (33 ft)

Plug connection

1st S0 2a 1a 1b 2b
3 4 5 6

2nd S0 (not connected 1 2 7 8


with G2-S0-I)
not 2b 1b 1a 2a
connected 6 5 4 3

not
connected

Socket Plug
GEAC 700

If the socket RJ 45 is installed by your Telecom provider, the termination re-


sistors (2 x 100 Ohm) are usually already integrated. If the installation board
GEAC 700 is connected directly to the NTBA, no termination resistors are ne-
cessary, but the line may not be longer than 10 m (33 ft).

LED-Status Indication
LEDs on the card G2-S0-I (without picture)
Status S0 card (RUN):
LED is blinking in a one second rhythm: the card is working correctly.
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor
(during initialization).
LED blinking fast: card inserted in wrong slot.

Status 1st S0 and 2nd S0:


B1 and B2 are on: Layer 1 monitoring ok (Telecom feature)
B1 and B2 are off: Layer 1 monitoring not activated or a fault has ocurred
B2 blinks in a rhythm of one second: the 1st B-channel is connected (data
transfer) chargeable time is running for one connection.
B1 blinks in a rhythm of one second: the 2nd B-channel is connected
(speech transfer) chargeable time is running for a second conection.

Page 30 of 35 Vers. 1.1/1202


GE 200 Installation

2-wire Network Card G7-CNET-W


For the G7-CNET-W (plug-in card in Euro format) an interface housing GEI
200 is required (see Connection of Interface Housing GEI 200 on page 20).
Detailed information about start-up and programming can be found in the
manual G7-CNET-W.
For connection the installation board GEA CNET, which is included in the ex-
tent of supply, must be used:

IN2 OUT2 RS 232


5 4 3 2 1
SHIELD
1
HDSL 2
9 8 7 6

GEA CNET 2=TXD, 3=RXD, 5=GND

If only one G7-CNET-W is


used, IN2 has to be 2xG7-CNETW: 1xG7-CNETW:
connected with OUT2
on the installation board
GEA CNET.
If two G7-CNET-W are
used, IN2 of the first OUT2 OUT2 OUT2
G7-CNET-W has to be
connected with OUT2 IN2 IN2 IN2

of the second G7-CNET-


W and OUT2 of the first
G7-CNET-W has to be GEA CNET GEA CNET GEA CNET
connected with IN2 of (G7-CNET-W) (G7-CNET-W) (G7-CNET-W)
the second G7-CNET-W.

LED-Status Indication
LEDs on the card G7-CNET-W (without picture)
Status G7-CNET-W (RUN):
LED is blinking in a one second rhythm: the card is working correctly.
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor
(during initialization).
LED blinking fast: card inserted in wrong slot.

Status 2-wire line (HDSL):


LED is permanently on: 2-wire line ok.
LED is permanently off: 2-wire line not connected.
LED flickers: data error on 2-wire line

Status connection to further CNETW (GEV):


LED is permanently on: connection ok.
LED is permanently off: no connection.
LED blinking fast:
- Synchronisation and/or data is not received correctly, or
- Cables are connected in an incorrect way, or
- Data error causes short blinking.
Status Master/Slave (CNT):
LED is permanently on: G7-CNET-W defined as Master.
LED is permanently off: G7-CNET-W defined as Slave.

Vers. 1.1/1202 Page 31 of 35


Installation GE 200

E1-Network Card G7-CNET-E1


For the G7-CNET-E1 (plug-in card in Euro format) an interface housing GEI
200 is required (see Connection of Interface Housing GEI 200 on page 20).
Detailed information about start-up and programming can be found in the
manual G7-CNET-E1.
For connection the installation board GEA CNETEW, which is included in the
extent of supply, must be used:

IN2 OUT2 CNETE1


RxA
RxB
TxA
TxB

GEA CNETEW NT (Standard) TxA


TxB
NetworkTermination Mode NC JP1
RxA JP2
RxB JP3
NC JP4
NC
NC

TE RxA
RxB
Terminal Equipment Mode NC JP1
TxA JP2
TxB JP3
NC JP4
NC
NC

If only one G7-CNET-E1 is used, IN2 has to be connected with OUT2 on


the installation board GEA CNETEW. If a second G7-CNET-E1 or an additio-
nal G7-CNET-W is used, IN2 of the first G7-CNET-E1 has to be connected
with OUT2 of the second G7-CNET-E1 (G7-CNET-W) and OUT2 of the
first G7-CNET-E1 has to be connected with IN2 of the second G7-CNET-E1
(G7-CNET-W), as it is with G7-CNET-W, figure see page 31).

LED-Status Indication
LEDs on the card G7-CNET-E1 (without picture)
Status G7-CNET-E1 (RUN):
LED is blinking in a one second rhyythm: the card is working correctly.
LED is permanently off: no power, reset or hardware fault.
LED is permanently on: waiting for connection to the main processor
(during initialising).
LED blinking fast: card inserted in wrong slot.

Status connection to other central (E1):


LED is permanently on: connection to other central ok.
LED is permanently off: no connection to other central.
LED flickers: data error

Status connection to further CNET (GEV):


LED is permanently on: connection ok.
LED is permanently off: no connection.
LED blinking fast:
- Synchronisation and/or data is not received correctly, or
- Cables are connected in an incorrect way, or
- Data error causes short blinking.
Status Master/Slave (M/S):
LED is permanently on: G7-CNET-E1 defined as Master.
LED is permanently off: G7-CNET-E1 defined as Slave.

Page 32 of 35 Vers. 1.1/1202


GE 200 Installation

Setting the System Numbers


If several centrals GE 200/GE 700 shall be connected to a network (e.g. via
S0, CNET-W or CNET-E1), each central must be given a unique number.

There are two methods for numbering the housings:


With the DIP-switches of the G7-GEP (for a maximum of 14 housings).
This is the easiest method, because the PC does not need to be connected
to each single housing.
With the program CCT, e.g. for more than 14 housings or if the pro-
gramming for a central should be prepared in advance.

Attention: The standard calling numbers, that are automatically allocated


for the housings (see Switch position on page 33), must be changed by
programming if more than 9 housings are connected. Otherwise three- and
four-digit numbers beginning with the same digits would occur (e.g. 110 in
housing no. 1 and 1101 in housing no. 11).

Setting the numbers with DIP-switches


1. Initialize each housing with the desired number (1 to 14):
- Set the DIP-switches 1 to 4 on the motherboard to ON.
- Switch the central off and back on.
- Set the desired number (switch position see below).
- Switch the central off and back on.
Attention: Initialising the central resets the programming.

2. Connect the PC to any housing of the central and read out the pro-
gramming of the central with the program CCT (menu Central -
Receive...). Now all cards are recognised correctly and the central can be
programmed as usual. For programming the PC can be connected to any
housing, all housings are programmed like a single central.

Switch position
Housing DIP-switches: Standard calling Housing DIP-switched: Standard calling
number: 1 2 3 4 numbers: nummer: 1 2 3 4 numbers:

1 1 0 0 0 101-148 8 0 0 0 1 801-848
2 0 1 0 0 201-248 9 1 0 0 1 901-948
3 1 1 0 0 301-348 10 0 1 0 1 1001-1048 *
4 0 0 1 0 401-448 11 1 1 0 1 1101-1148 *
5 1 0 1 0 501-548 12 0 0 1 1 1201-1248 *
6 0 1 1 0 601-648 13 1 0 1 1 1301-1348 *
7 1 1 1 0 701-748 14 0 1 1 1 1401-1448 *
1=switch position ON, 0=switch position OFF

* Attention: with system numbers higher than 9 the standard calling numbers have to be changed. Other-
wise 3- and 4-digit calling numbers starting with the same digits occur (e.g. 110 in housing no. 1, 1101 in
housing no. 11).

Vers. 1.1/1202 Page 33 of 35


Installation GE 200

Setting the numbers with CCT


1. Select the function Cards in the folder Central. Click on the button
Add Central. Select the button GE 200 or GE 700 at Type of Cen-
tral, enter the desired number at System Number and acknowledge
with Ok.

2. Click on the button Add Central again. Select GE 200 or GE 700 at


Type of Central. Enter the next number at Central Number and ack-
nowledge with Ok. Repeat this procedure for all further housings. At
Central-Description at the top right side of the screen an optional text
can be entered for each housing.

3. Select Initialize... in the menu Central.

4. Connect one housing after the other to the PC and select Initialize.... In
the left field Central No. the current central number is displayed. Enter
the desired number in the field New No. and click on Initialize.

As soon as the number is transferred, the number appears in the Availa-


ble centrals box.

5. Read out the programming of the central (menu Central - Receive..., in


the window Central reached all housings have to be selected). Now all
cards are correctly recognised and the central can be programmed as
usual. For programming, all housings are programmed like a single cen-
tral - the PC can be connected to any housing.

Page 34 of 35 Vers. 1.1/1202


GE 200 Technical Support

Technical Support
For more information about our products and services visit:

www.software-manuals.com

Vers. 1.1/1202 Page 35 of 35