Professional Documents
Culture Documents
These unique mini-clamp meters meet your needs when measuring up to 400 amps.
Their compact size make them a handy daily tool to fit into the slightest of tool kits. With an
CLAMP METERS
easy to read digital display, Data Hold capability, Analog Bargraph and 10 mA resolution when
using the 40A range.
B TRMS (ACD-6 TRMS-PRO) when measuring in B Audible continuity B TRMS & Backlight Screen (ACDC-100 TRMS only) B Audible continuity
noisy AC environments (ACD-6 TRMS-PRO only) B Includes carrying case B Auto and manual ranging B Large digital display
B AC Current to 1000A B Extra large LCD for easy viewing of . B Relative zero mode B Carrying case, test leads, batteries
B AC/DC voltage to 600V measurement results B Auto power off and user manual included
B Resistance to 40 M B Jaw opening 45 mm B MAX capture function for inrush current . B Jaw opening 50 mm
B Diode Test B Safety acc. EN 61010, CAT III/600 V measurements (30 ms response) B Safety acc. EN 61010, CAT III/600 V
B Data hold
ACD-15 TRMS-PRO
2000 A AC Digital Clamp Multimeter
AD105A
True RMS 1000 A AC/DC Clamp Meter The AC-15 clamp meter for when you need to measure high current. Measures up to 2000A AC.
Plus it measures AC and DC voltage, resistance and offers audible continuity. Additional feature is
A clamp meter designed for electrical contractors, electricians, and industrial plant maintenance a built in non-contact voltage detector. Choose the True RMS version when working in noisy AC
personnel. The AD105A measures AC and DC current up to 1000 Amps. Frequency is measured environments. Large digital display.
by jaw up to 10kHz. Max Conductor of 50 mm.
B TRMS & Backlight Screen B Auto and manual ranging
B TRMS when measuring in noisy . B 4000-count B Measurements: AC/DC Voltage up to B Auto power off
CLAMP METERS
AC environments B Belt-clipsleeve case included 600V, AC Current up to 2000A, B Data hold
B Wide range to 1000 Amps, AC and DC B Jaw opening 50 mm Resistance, Frequency and Capacitance B Carrying case, test leads, batteries
B Measures frequency through the jaws or . B Safety acc. EN 61010, CAT III/1000 V B Non-contact Voltage Level Detection (installed) and manual included
test leads B Audible continuity B Third hand - test probe holder
B Autoranging B AutoTect feature automatically B Jaw opening 45 mm
selects DCV, ACV or Resistance B Safety acc. EN 61010, CAT III/600 V
B Resistance measurement
and continuity beeper
CLAMP METERS
Automatic AC clamp meter with two unique features: AutoTect and automatic
backlight. The AutoTect feature senses what type of measurement is being made across Recording Clamp Multimeters
the test leads. The automatic bright blue backlight has a sensor that recognizes when the
ambient light becomes dim and turns itself on. Need the perfect tool to troubleshoot a system? These clamp-ons provide a full range of
B AutoTect Function automatically B DC volts to 1000 V measurements, enhanced with data logging capabilities, to catch what the eye cant see.
selects AC volts, DC volts or resistance B Resistance and Continuity Beeper Double the efficiency, with an optional PC interface kit (RS-232 KIT2).
B Automatic bright blue backlight B Data Hold
B Easy one-button control B Jaw opening 32 mm ACD-16 PRO, ACD-16 TRMS-PRO
B AC current to 600 A B Safety acc. EN 61010, CAT III/600 V, .
1000A AC Data-Logging Clamp Multimeters
B AC volts to 750 V CAT II/1000 V
B TRMS & Backlight Screen . B Auto power off
(ACD-16 TRMS Pro only) B Automatic polarity
B Measurements: AC/DC Voltage up to B Data hold
4 n, 40 n, 400 n, 4 ,
Capacitance 40 , 400 , 4 mF
N/A
CLAMP METERS
Apparent (VA) Power with B Jaw opening 45 mm
Power Factor B Safety acc. EN 61010, CAT III/600V
B TRMS Measurement B 43 Segment, High speed, Analog
B Auto VA - Auto Selection of AC Volts,
B AC Voltage up to 750V, DC Voltage up Bar Graph
DC Volts or AC Amps (ACD-41PQ only)
to 1000V, AC/DC Current up to 1000A, B Continuity Buzzer
Resistance, Frequency, % Duty Cycle, B Auto/Manual Ranging and
Continuity Buzzer Auto Power Off
B Dynamic Recording of Max, Min and B Jaw opening 52 mm ACD-56 HPQ Power Quality Digital Clamp Multimeters
Average readings B Safety acc. EN 61010, CAT III/600 V
B TRMS & Backlight Screen B Auto and manual ranging
B In-rush Peak Current capture (1 ms response)
B AC Current up to 400A B Auto-check feature automatically
B Dual Display of Amp & Freq.,
B AC/DC Voltage up to 600V selects DCV, ACV or Resistance
Amps & Duty Cycle, Voltage & Freq.,
B Resistance B MAX/MIN/AVG recording
Voltage & Duty Cycle
B Frequency B Auto power off
B Capacitance B Third hand - test probe holder
ACD-330T Digital AC Clamp Multimeter B Voltage and Current Harmonics up to 25th . B Jaw opening 30 mm
with THD% B Safety acc. EN 61010, CAT III/600 V
B TRMS Measurement B Continuity Buzzer and Diode Test B Non-contact Voltage Level Detection
B AC/DC Voltage up to 1000V, AC Current up to B Auto/Manual ranging B Audible continuity
1000A, Resistance, Continuity Buzzer, Frequency B Auto power off
B Dynamic Min/Max/Avg Recording B Jaw opening 52 mm
B In-rush Peak Current capture (1 ms) B Safety acc. EN 61010, CAT III/600 V
B Reading Hold function
B Dual Display of Frequency with Current or Voltage
Capacitance 400.0, 4000 F N/A N/A Power Factor 0.10 to 0.99 0.20 - 1.00
B 10,000-count with high 0.25 % accuracy 30XR-A Includes VolTect, a built-in non-contact
B Bright blue backlight for dim environments voltage tester
B Duty cycle, capacitance and frequency
B Magne-Grip holster with magnetic hanging strap
The 30XR-A has all the basic functions for automotive, residential and
B 4-20 mA loop current with % readout
education applications.
B Temperature to 1300 C, type K thermocouple included
MULTIMETERS
B True-RMS AC + DC coupled for accurate measurements B 9 functions, 30 ranges handles most measurement needs
B RS-232 data out for use with optional software, Model 38SW-A B Magne-Grip holster with magnetic hanging strap frees both
B Safety acc. EN 61010, CAT IV/600V, CAT III/1000 V hands for work
B Battery/fuse door designed for easy accessibility
B Battery tester
B Safety acc. EN 61010, CAT III/300V, CAT II/600 V
37XR-A
True RMS with component and logic test
True RMS meter for electronics troubleshooting at the bench or job site. The
highest accuracy meter in the XR series.
B Autoranging 10,000 count with 0.1 % accuracy for the most .
accurate measurements
B LCR functions: inductance, capacitance and resistance FEATURES 30XR-A 33XR-A 34XR-A 37XR-A 38XR-A
Magne-Grip
B Frequency, duty cycle and logic test Holster with
B Bright blue backlight for dim environments 200.0mV, 2.000, 400.0m, 4.000, 40.00, magnetic
B Magne-Grip holster with magnetic hanging strap
DC Voltage 20.00, 200.0, 600V 400.0, 1000V 1000m, 10.00, 100.0, 1000V hanging
B Safety acc. EN 61010, CAT III/600V, CAT II/1000 V 200.0mV, 2.000,
strap
AC Voltage 20.00, 200.0, 600V 400.0m, 4.000, 40.00, 400.0, 750V 1000m, 10.00, 100.0, 750V
This
holster
200.0, 2.000m, 400.0, 4.000m, 40.00m, 100.0, 1000, 10.00m, 100.0m,
20.00m, 200.0m, 10A 300.0m, 10.00A 400.0m, 10.00A
protects
DC Current
the meter
and provides the third
200.0, 2.000m, 400.0, 4.000m, 40.00m, 100.0, 1000, 10.00m, 100.0m,
AC Current 20.00m, 200.0m, 10A 300.0m, 10.00A 400.0m, 10.00A hand DMM users need.
A magnetic hanging strap
secures the meter to a
34XR-A 200.0 , 2.000k,
400.0, 40.00k,
400.0, 4.000k,
1000.0, 10.000k, 100.00k, 1000.0k, convenient steel surface,
Resistance 20.00k, 200.0k, 40.00k, 400.0k,
True RMS with temperature and backlight 2.000M, 20.00M
4.000M
4.000M, 40.00M
10.00M, 40.00M freeing both hands for work.
Designed for maintenance, repair and installation of electrical and Continuity Yes
electro-mechanical equipment. Ideal for contractors and field service technicians.
Diode Yes
MULTIMETERS
200.0, 2.000m, 200.0, 2.000m, 20.00m, 400.0A, 4.000A, 40.00mA,
Current AC/DC 20.00m, 200.0mA 200.0m, 2A 400.0mA, 2A
Non-contact voltage 70 V to 600 VAC (50 Hz to 60 Hz) Current AC/DC 400.0, 4000, 40.00m, 400.0m, 4.000, 10.00A N/A
4.000n, 40.00n, 400.0n, 4.000, 400.0, 4.000k, 40.00k, 400.0k, 340.0, 3.400k, 34.00k, 340.0k, 3.400M,
Capacitance N/A
40.00, 400.0, 4.000mF Resistance 4.000M, 40.00M 34.00M
Frequency N/A 4.000k, 40.00k, 400.0k, 1MHz Capacitance 40.00n, 400.0n, 4.000, 40.00, 400.0, 4000F N/A
Temperature N/A -20 C to1000 C Frequency 10.00, 100.0, 1000, 10.00k, 100.0k, 1000k, 10MHz N/A
Logic test N/A TTL, 20 MHz N/A Diode N/A Yes
Battery test 1.5 V, 9 V N/A Continuity Yes
Available on all XP Series meters: Magne-Grip Holster with magnetic hanging strap frees both hands for work. Duty Cycle 0.1%-99.9% N/A
VolTect non-contact voltage detection lets you instantly detect dangerous ac line voltages. Temperature N/A -50 to 750C N/A
MULTIMETERS
Low Z input impedance to eliminate ghost voltages. Hi Z input impedance for electronic circuitry safety rated
(PM55A only).
DM9C Compact autoranging meter
PM55A Automatic Precision Pocket Multimeter B High-resolution, B Protective holster included
B AutoTect feature detects and displays AC volts, DC volts or resistance 4000-count autoranging B Safety acc. EN 61010, CAT II/600 V
B VolTect feature, a built-in AC voltage detector B 7 functions/23 ranges
B Extra features of capacitance, frequency and microamp current B Battery Test Function
B Option of Hi Z or Low Z input impedance for ghost voltages with Go/NoGo LED indicator
B Includes zippered carrying case and protective holster
B Safety acc. EN 61010, CAT III/300 V, CAT II/600 V
DM78B Voltage, continuity, diode and
resistance in a credit card size meter
PM53A Pocket size digital multimeter with AutoTect
B 5 functions/16 ranges B 3200-count display with
B Non-contact AC voltage detection, VolTect feature B Continuity test: Buzzer alert analog bargraph
B AutoTect feature detects and displays AC volts, DC volts or resistance
B Auto power off saves batteries B Safety acc. EN 61010, .
B Low Z input impedance eliminates ghost voltage readings
B Data Hold CAT II/300 V
B Safety acc. EN 61010, CAT III/300 V, CAT II/450 V
B Protective case included
400.0m, 4.000, 40.00, 2.000, 20.00, 400.0m, 4.000, 40.00, 320.0m, 3.200, 32.00, 2.5, 10, 50, 150,
Voltage AC/DC 400.0, 600V
6.000, 60.00, 450.0V 6.000, 60.00, 600.0V DC Voltage 200.0, 600V 400.0, 600V 320.0, 600V 300 V
MULTIMETERS
heavy-duty meter
FEATURES AM-150 AM-140 AM-160
B True-RMS (TRMS), 10,000-count
50.00, 500.0mV, 5.000, 50.00, 500.0, 500.00m, 5.0000, 50.000, 500.00,
ACVoltage 1000V 1000.0V B RelativeMax/Min/AVG, Hold and Range Lock
B Digi-Glo backlight
DCVoltage
50.00, 500.0mV, 5.000, 50.00, 500.0, 500.00m, 5.0000, 50.000, 500.00, B Temperature, Capacitance and Frequency
1000V 1000.0V
Resistance
50.00, 500.0, 5.000k, 50.00k, 500.0k, 500.00, 5.0000k, 50.000k, 500.00k, HD110C General purpose heavy-duty meter
5.000M, 50.00M 5.0000M, 50.000M
B Data Hold HD160C
500.0, 5000, 50.00m, 500.0m, 5.000, 500.00, 5000.0A, 50.000m, 500.00m,
Current AC/DC 10.00A 5.0000, 10.000A
50.00n, 500.0n, 5.000, 50.00, 500.0, 50.00n, 500.0n, 5.000, 50.00, 500.0,
Capacitance 9999F 9999F
Dual thermocouple
Temperature -50 C to 1000 C
-50 C to 1000 C
HD110C
Data Recording 5400 Points N/A
AC Voltage 200.0m, 2.000, 20.00, 200.0, 1000 V 1000.0 m, 10.000, 100.00, 1000.0 V
OPTIONAL ACCESSORIES PART NUMBER
200.0, 2.000m, 20.00m, 100.00, 1000.0, 10.000m, 100.00m,
3000 A AC Flexible Clamp-on Attachment ACF-3000 AK Current AC/DC 200.0m, 2 A 400.0m, 2.000A
1000 A TRMS AC/DC Clamp-on Attachment A-1000
200.0, 2.000k, 20.00k, 200.0k, 1000.0, 10.000k, 100.00k, 1000.0k,
Resistance 2.000M, 20.00 M 10.000M, 40.00M
600 A AC/DC Clamp-on Attachment CT-600 AC/DC
The measuring pulse fed into the cable will reflected by in homogeneity of the cable B Performs tests without having to B Locates breakers, neutral & ground lines
impedance (cable faults) and showed on the display. The distance and the kind of the fault interrupt power B Pinpoints shorts, ground faults &
can be determined out of the shape and the time setting of the reflection (Practical B Locates and traces wires in walls, broken wires
experience can be obtained by test measurements). If the cable is terminated with a floors, conduit, computer cables, etc.
resistance equal to the impedance of the cable, no reflexion occurs when the cable is
faultless. In the case of breaks, contact faults in sleeves, short circuits or taps/splitter in the
sector to be tested, the distance to the cable beginning can be determined by the pulse
echo. If wide pulses are used for the measurement, the echoes are stronger, but faultless
FEATURES AT-2001 AT-2002 AT-2003 AT-2004 AT-2005
taps/splitter cause then strong echoes.
Traces energized wires without power 9-300V 9-600V 9-600V 9-600V
Propagation factor interruption.Locates breakers without (S-2300 (S-2600 N/A (S-2600 (S-2600
Frequency range 50 to 60 Hz
19,99 99,99 0,1
Insulation measurement 50 V, 100 V, 0,01 M 19,99 M 0,01 M
250 V, 500 V and 1000 V DC
20 M 199 M 0,1 M
200 M 1999 M 1 M
FI (RCD) tripping time adjustable test current IN: 1 ms
10, 30, 100, 300, 500 mA
Multifunction Installation Testers tripping time (max. Range)
0 9,99
FI RCD) tripping current (0,5 2,0) x IN 10 % IN
Genius 5035 FI (RCD) Ra 0 2 k/Itest =1/2 IN 1
Multifunction Installation Tester FI (RCD) Ub 25 or 50 V touch current 1V
Line/Loop impedance (Zs, Zi) 0,01 19,99 0,01
Genius 5035 is a multifunction tester for installation testing acc. to IEC 60364, DIN VDE
0100, VE E 8001, NIN/NIV, 16th Edition. With the Genius multifunction installation tester 20,00 199,9 0,1
you can perform following measurements: 200,0 2000 1
Test current Itest 0 4 A (80 ms) at 110 V, 6 A (40 ms) at 230 V, 11 A (40 ms) at
B Insulation resistance EN 61557-2 100 V, 250 V, B Measurement of earth resistance EN 61557-5 400 V
500 V, 1000 V DC without causing RCD tripping Short circuit current Ik 1 A ... 1 kA ... 10 kA 1 A and 1 kA
B Line and loop impedance EN 61557-3 and . B Phase Rotation EN 61557-7 Loop impedance without RCD 1 1999 1
prospective short circuit current B Frequency and Voltage Measurement tripping
B Low resistance measurement EN 61557-4 . Frequency measurement 15,3 99,9 Hz 0,1 Hz
with > 200 mA DC Phase sequence and voltage 110 440 V 1V
B RCD-Analysis EN 61557-6 . measurement
Measurement of tripping time, tripping currrent, RS 232 interface optoinsulated serial output
touch leakage voltage Ub with and without RCD Memory locations 350
tripping Power supply 6 x 1,5 V Type AA for appr. 500 insulation measurements
For detailed specifications, see table GSC 53A on page 34 and 35 Weight appr. 990 g
Auto off 10 min
Safety class, standards EN 61010-1, CAT III 600 V, all measurements according to
VDE 0413 (EN 61557) part 1, 2, 3, 4, 6 and 7
Standard accessories incl. carrying case, test leads with Shuko plugs, 3 alligator clips, 3 safety-test
leads with banana jack, software (Eurolink 2000), memory, RS232 cable,
manual, calibration certificate and batteries.
FEATURES
Display Resolution LCD, 3-digit, 1999 Digits
Measurement Ranges
Frequency 0,1 Hz 10...99,9 Hz Display 3 digit, LCD, 1999 Digits Measurement ranges /
Resolution
Loop Impedance 0,01/0,1/1 0,1519,99./199,9/1999
Nominal test current 10 / 30 / 100 / 300 / 500mA/ 1 A
Prospective Short time delayed: 100mA/ 300mA/ 500 mA / 1 A
Circuit Current 0,01A...0,1 kA 0,10 A...1,7 kA
Input Voltage Range 195...264 V 50/60 Hz Contact voltage 0.6...70 V / 0.1 V
Test Current approx. 4,6 A (at 230 V) Tolerance (-0%...+10%) + 6 Digits
Line Resistance 0,01/0,1/1 0,1519,99/199,9/1999
Trip time 2...1999 ms / 1 ms
Prospective Short
Circuit Current 0,01A...0,1 kA 0,10 A...2,7 kA Tolerance (2%+2 Digits)
Input Voltage Range 195...440 V 50/60 Hz
Test Current approx. 4,6 A (at 230 V) Test current type AC, DC, DC pulse
Loop Resistance 0,5...19,99/199,9/1999
Earth resistance 0.01...1999 / 1
(without tripping the RCD) 0,01/0,1/1
Tolerance (10%+10 Digits)
Prospective Short
Circuit Current 0,01A...0,1kA 0,50 A...0,5 kA Mains voltage 230 V +10% / -15%
Input Voltage Range 195...264 V 50/60 Hz
Test Current approx. 5 mA (at 230 V) Data memory approx. 100 measurements
Insulation Resistance 0,01/0,1 M 0,05...19,99/199,9 M
Test Voltage 100, 250, 500 V DC Interface IR/RS-232 interface-adapter
Low Ohm Measurement 0,01/0,1/1 0,05...19,99/199,9/1999 Protection class II (double insulated)
Test Current > 200 mA DC
Safety complying with IEC61010/EN61010/DIN VDE 0411
RCD-Test Nominal 10, 30, 100, 300, 500mA IEC61557/EN61557/DIN VDE 0413
currents 0,5 x 30mA, 5 x 30mA
selective: 100, 300, 500mA Measurement category CAT III / 300 V
Measurement Contact voltage,
Functions trip time, Tripping current test with ramp Pollution degree 2
method
Contact Voltage 1...63 V Protection degree IP 50
Earth Resistance 1 /0,01 k 101999 /19,99 k Power supply 6 x 1.5 V, IEC LR6
Tripping Time 1 ms 1...500 ms
Tripping Current 40...140% of IN (in 10% steps)
Line resistance 0.05...19.99/ 0.01/(5% rdg.+ 5 Digits) Insulation resistance (500 VDC) 4.000, 40.00, 400.0, 4000M 400.0, 1000.0M
Resistance neutral connector 0.05...19.99/0.01/(5% rdg.+ 5 Digits)
Insulation resistance (1000 VDC) 4.000, 40.00, 400.0, 4000M 400.0, 2000.0M
Resistance earth connector 0.05...1999/0.01...1/(5%rdg.+5Digits)
Resistance phase connector 0.05...19.99/0.01/(5% rdg.+ 5 Digits) Resistance (9V) N/A 999.9
Test current
6...625 V AC / 01000 V DC
approx. 1mA
AMB-5KVD
Low Ohm measurement 0.03...19.99 /0.01 Digital 5 kV Insulation Resistance Tester
Test current > 200mA
B Tests insulation of wires, cables, B Performs the dielectric absorption
Memory approx. 500 Values
transformers, motors and generators ratio test
Interface IR/RS-232 Interface adapter
B Comes as a complete kit including B One testing instrument for low
Safety complying with IEC 61010/EN 61010/
DIN VDE 0411/IEC 61557/EN61557/DIN VDE 0413
test leads and PC software and high voltage systems
B Built in automatic voltmeter up to B Internal memory, measurements
Measurement category CAT III/600 V
5000V warns against hazardous can be stored for future reference
Pollution Degree 2
energized systems B Data download to PC
Protection Degree IP 50
B Programmable setups of test B Rugged, durable case
Power Supply 6 x 1.5 V, IEC LR6
voltages and timers
ISO-PLUS-A AMB-5KV
Insulation Tester & TRMS Multimeter Analog 5 kV Insulation Resistance Tester
Universal insulation measuring instruments for testing electrical equipment, devices, cables,
B Tests insulation of wires, cables, B Lock feature applies testing voltage
machines in electrical workshops and industry.
transformers, motors and generators continuously for Dielectric
B Easy to use handheld design measuring V, , M, Hz, A (mA) B Test voltages 500, 1000, 2500, 5000 VDC Absorption Ratio Test
B Large dual display with bright EL backlight and bargraph B Measuring range 500K thru 500G ohms B Automatic discharge of
B Advanced safety features including live circuit protection without fuse damage, test lock out and B Built-in voltmeter 0 600Volts equipment capacitance for
auto discharge after test operator safety
B Fully compliant with all European standards for insulation testing
B Insulation measurements up to 20 G with 100, 250, 500 and 1000V test voltages and display of
test current FEATURES AMB-5KVD AMB-5KV
Insulation Testers
B On screen display of Polarisation Index and Dielectric Absorption Ratio for insulation quality
Insulation resistance (500 VDC) 100 k to 100 G 500 k to 100 G
B Auto ranging resistance measurement to 200k with a selectable 200mA or 50mA low resistance
test lead compensation Insulation resistance (1000 VDC) 100 k to 250 G 500 k to 250 G
B Continuity test with adjustable thresholds, fast-responding buzzer and visual indicator (buzzer
Insulation resistance (250 VDC) 100 k to 500 G 500 k to 500 G
can also be de-activated)
B True RMS voltage measurement with display of AC, DC and AC+DC values and mV resolution Insulation resistance (5000 VDC) 100 k to 500 G 500 k to 500 G
B Leakage current measurement directly or with LEM current probes in current ranges from 200
Voltage AC/DC 500, 5000 V 600.0 V
A to 200A
B LIMIT (adjustable alarm) to quickly and reliably identify fault conditions
B REC function for MIN, MAX, AVG values
B ZERO (REL) function to compensate measuring leads and for relative measurements
B Safety acc. EN 61557-2, -4, EN 61010, CAT III / 600V
General
Download Suite Software Package
1999 digit dual LCD with special symbols, digit height 17 mm, 30 segment analogue
Display Download Suite is a software package compatible with the Amprobe instruments with download
bar with over/ underflow and special display symbols, EL backlight Do ib
le
wn at capabilities.
load mp
Protective type IP40 according to EN 60529 Suite Co
External voltage Measurement inhibited for external voltage Ux >10% of UN for M and >3V for - Install software once and use it with various Amprobe products
Max. overload 800 V eff RMS or RMS x frequency < 5x104 VHz - Download Suite features one installation and download package for all supported Amprobe Products
Auxiliary power 4 x 1.5 V mignon cells alkali-manganese(IEC LR6) - One file format - all instruments share the same file format. You can open files recorded by you, other people, or even
M - RISO Insulation Resistance other Amprobe instruments right on your PC
Method Voltage/current measurement as per EN 615572
- Download Suite automatically checks your version for upgrades and keeps your version current.
Nominal test voltage UN = 100V, 250V, 500V, 1000V DC
The software es control support the following products:
Open circuit voltage U0 < 1.1 x UN AMB-45
Nominal current IN 1mA DC at UN IN 2.5mA DC at 100k at 250V AMB-5KVD
Short circuit current <10mA DC
R Low Resistance Measurement Available in English only.
Method Voltage/current measurement as per EN 615574
Open circuit voltage U0 4V
Short circuit current Ik 200mA DC up to 2 as per IEC 61557
VP-440
Phase Sequence
VP-600SB Non-Contact VoltProbe Phase sequence testing is crucial for some of the three-phase loads, whenever they need to be
connected to the electrical system. Improper connection of three-phase motors may lead to
B Detect AC Voltage (100 - 600 V) B Testfor AC Voltage cables, circuit breakers, wall reverse rotation, and as a result it may damage equipment powered by a motor. Amprobe's
B Use non-contact method of Voltage testing sockets, .
ELECTRICAL TESTERS
Phase Sequence and Motor Rotation Tester is used to assure used to assure proper and safe
B Totally insulated, no exposed metal or . junction boxes, fuses, etc. connection of the electrical equipment on three-phase systems.
conductive parts B Safety acc. EN 61010, CAT III/600 V
B Check for AC Voltages without necessity of .
disconnecting the electrical system PRM-3 Phase Sequence & Motor Rotation Tester
B Phase sequence indication of the B Phase voltage loss or voltage
three phase electrical systems sag indication
FEATURES VP-440 VP-600SB B Check for normal or reversed phases B Safety acc. EN 61010, CAT III/600 V
B Comprehensive real time monitoring, recording B Internalmemory for 99 single Note: only available in English or German language.
and analysis of three phase power systems measurement storage
B True-RMS voltage and current measurement B Opto-isolated RS232 interface for further
B Power Factor and phase angle results analysis and charting Voltage and current measurement
B Power Analysis (apparent, active and . B 50 Hertz operation facilities
Function Range (V) Resolution (V) Input impedance Overload
reactive power) protection
B Additional current clamp for neutral line Voltage measurement 300, 600 (Autorange) 0.2 300 kOhm 900 V (1 min.)
monitoring Current measurement 1 0.001 100 kOhm 5V
PF measurement
FEATURES PQ55A Function PF Resolution
Voltage measurement 600 Vrms PF measurement 0.2 0.01 digits
0.5 0.01 digits
Current measurement Input I1, I2, I3 999.9 A
0.8 0.01 digits
Input I4 250 A
Clamp opening 40 mm
Frequency measurement 45 to 80 Hz
POWER QUALITY
1 - 999.9 MVA 0.1 MVA
0 - 999.9 WH 0.1 WH
Active energy
1 - 999.9 kWH 0.1 kWH
(Class 2 IEC 1036)
1 - 999.9 MWH 0.1 MWH
0 - 999.9 VARH 0.1 VARH
Reactive energy
1 - 999.9 kVARH 0.1 kVARH
Power Quality Analyzers (Class 3 IEC 1268)
1 - 999.9 MVARH 0.1 MVARH
ENERGYTEST 2020 E is equipped with 2 MB memory. The selected recording rate (5 sec. to 60 min.)
ENERGYTEST 2020 E and the amount of selected channels (1-64 signals) determine the maximum recording time.
Example: With an interval of 10 s and 5 selected parameters the max. recording time is 4 days
Handy 3-Phase Power Analyzer and 8 hours. With an interval of 1 min. the recording time is 26 days. This includes up to
ENERGYTEST 2020 E is a three-phase power analyser and recorder capable of carrying out a 35 recordings/measurement that can be stored
complete analysis of voltages, current and related harmonics, active and reactive powers as well
as active and reactive energies. It also permits to analyse the voltage and current harmonic
components to check and possibly solve all the problems related to the harmonic presence.
3 Phase Power Analyzer and Multifunction Installation Tester Analog input (only GSC-53 A) -1000 m VDC - +1000 mV DC AC Voltage
Resolution 0,1 mV Range 500 V
B Insulation resistance: test voltage 50 V, 100 B RCD testing: tripping time, tripping current,
Temperature adapter (HT52) -40 C - 80 C Resolution 1V
V, 250 V, 500V, 1000 V DC, EN 61557-2 touch leakage voltage Ub, EN 61557-6
B Loop and line impedance, display of short B Measurement of earth resistance and ground Humidity (HT52) 10 - 98 % RH Frequency
circuit current Ik, EN 61557-3 resistivity, EN 61557-5 Intensity of light (HT53) 0 - 20.000 Lux Range 15,3 - 99,9 Hz
B Low ohm measurement with > 200 mA DC, B Phase sequence, EN 61557-7
Low Ohm range (Low resistance 100 - 499 Hz
EN 61557-4 0 - 20 Ohm
measurement)
Resolution 0,1 Hz
Resolution 0,01 Ohm
1 Hz
Safety standards: The instrument complies with the general safety appointments according to EN Test current > 200 mA DC
Phase sequencing L1, L2, L3 or L2, L1, L3
61010-1, CAT III 600 V for voltage measurement. Open circuit viltage > 4,5 V
Display: Graphical dot matrix RCD tests
Test lead compensation Yes
Resolution: 128 x 128 (16384 pixel) RCD type AC, A and selective
Visible region: 73 x 73 mm Insulation resistance
Rated tripping currents 10 mA, 30 mA, 100 mA
Accessories: Clamp-Ons and adapter for the 3 analog inputs. The transforming ratio for the Test current 100, 250, 500, 1000 V DC
300 mA, 500 mA, 1000 mA
3 analog inputs is selectable. Depending on wich Clamp-On is used, the Range 0 - 1,999 MOhm
measuring rate can be extended from 5 mA to 3000 A. Trip Time (IN)
2 - 19,99 MOhm
*) with control Test current
1/2 IN
Additional Power Analyzer Function: 20 - 999,9 MOhm of contact voltage
Current, Voltage Harmonic analysis of voltages and currents **) excluding 500 mA
Resolution 1 kOhm 2 IN
Apparent power, reactive power, active Residual voltage, voltage drops and 1000 mA
Voltage peaks 10 kOhm
power, Power Factor 5 IN RCD S**
Power consumption, energy 100 kOhm
5 IN RCD**
Open circuit voltage 1,3 x Test voltage
Range 0 - 1999 ms
Additional Adapter Function: Short circuit current 1,4 mA (max.)
The GSC-53 A is equipped with 3 analog inputs that allows measurement (with adapters) and 0 - 199,9 ms
Rated voltage 1 mA
storage of the following environmental parameters: 0 - 150 ms
Temperature Humidity Lux Noise and Leq (dB) Type 1 Earth resistance
0 - 40 ms
Range 0 - 19,99 Ohm
Resolution 0,1 ms*
The GSC-53A is available in following versions: 20 - 199,9 Ohm
GSC-53A without clamp adapters Trip current
200 - 1999 Ohm
GSC-53A with 3 flex clamp adapters ACF-3003 Range (0,5 - 1,4) IN
Resolution 0,01 Ohm
Resolution 0,1 IN
Note: only available in English or German language. 0,1 Ohm
Touch current
1 Ohm
Range 0 - 100 V
Frequency 125 Hz 1 Hz (Sinus)
Resolution 0,1 V
Test current 10 mA
UB lim: 25 V or 50 V
General data of Genius 5035 + GSC-53 A General data of Genius 5035 Open circuit voltage 80 V
Power (only GSC-53 A)
Grafic display, back light (only Autonomy 5000 measurements Loop Impedanz Phase-Phase(Zpp), Phase-Neutral (Zpn),
Display GSC-53 A) Resolution 10 W
Phase-Earth (Zpe)
Relative humidity 85 %
Memory 128 kbyte (Genius 5035) Range 0 - 19,99 Ohm Harmonics (only GSC-53 A)
Safety: EN61010 CAT III 600 V
Interface RS232 20 - 199,9 Ohm Range 2. - 50. harmonic
POWER QUALITY
Protection class IP50
adjustable from 5 sec. up to 15 200 - 1999 Ohm Safety: IEC 1010 (VDE 0411)
Recording interval min. (only GSC-53 A) Dimension 225 x 165 x 120 mm all measurement according to VDE 0413 (EN 61557)
Resolution 0,01 Ohm
2 MB, Weight appr. 1500 g
Memory for appr. 700 - 1000 measuring 0,1 Ohm, 1 Ohm
GSC-53 A quantities for VDE 0100 Power supply 6 x 1,5 V, AA LR6
resp. max. 67 days recording Measuring 10 A 10 % (10 ms)
Calculation of short circuit current
Auto power off 10 min.
Ik max (theoretically) 40 kA
Earth resistance RE without RCD tripping
Range RE 0,1 Ohm - 10 kOhm
Test current 0,5 IN RCD
ENVIRONMENTAL TESTERS
sub-cool temperature measurements and software, TM-SWA A quick and effective diagnostic tool for identifying problems in a wide variety of
B Deluxe hard carrying case, 2 Type K probes applications like HVAC/R, fire safety and protection, industrial, maintenance, automotive.
ENVIRONMENTAL TESTERS
B Frequency range 31.5 Hz 8 kHz
B Measuring level range from 35 dB to 130 dB B Slow (1 sec) and fast (125ms) response
B A and C weightings for checking . settings to check peak and average .
compliance with safety regulations as well as noise levels
acoustic analysis
In areas where leaking gases are not sufficiently pressurized, there is no ultrasonic sound for Foot-Candles or Lux incidence of light (C.I.E sensitivity adjustment
detection. The area can be pressurized with the ultrasonic sound waves created by Amprobe's B Measures from 0.01 to 20,000 to photo optic curve)
UT-300 Ultrasonic Transmitter. This will allow the detection of cracks which would not normally Foot-Candles or Lux B Accuracy: 10,000 lux/fc range 3%
Diodes Yes Std (3 V) & microwave oven (8 V) Frequency Ranges 7 Ranges, 0.3 to 3MHz 7 Ranges, 0.3 to 3MHz
Output Amplitude 20Vp-p open circuit 20Vp-p open circuit
Continuity test Yes Yes
BENCHTOP INSTRUMENTS
Sine Wave distortion </= 1%, 0.3 to 200kHz </= 1%, 0.3 to 200kHz
COMPONENT TEST / RELAYS
Bench Multimeter
BDM40 Benchtop Meter with True-RMS
High resolution and ranges for a low cost makes this benchtop multimeter
ideal for production test, QA test, depost service and university or school labs.
ACCESSORIES
ACD-14 TRMS-FX
ACD-15 PRO
Test lead kit contains: Double insulated Silicon ACD-15 TRMS-PRO
Test Leads, Sharp Test Probes and Fully Insulated Alligator Clips ACD-16 PRO
ACD-16 TRMS-PRO
MTL-501 ACD-31P
ACD-41PQ
Test lead kit: Double Insulated Silicon Test Leads, Sharp Test Probes Fully ACD-56HPQ
Insulated Alligator Clips, USA Main Socket Test Adapters & Sprung Hook Tips ACDC-100
ACDC-100 TRMS
TL245A ACDC-620T
ACDC-3000
PVC insulated standard test leads, CAT III 1000V rated AM-140 TRMS
AM-150 TRMS
CC-DM-III VC221B
Deluxe Heavy Duty carrying case Vinyl carrying case
DC205C VC3A
Deluxe Heavy Duty carrying case Rugged zippered carrying case
DC207C VC30A
Deluxe Heavy Duty carrying case with Vinyl carrying case VC3A
compartment for current transformer
and extra accessories
GP-2CC DC205C
TL36A Soft pouch zippered carrying case
VC30A
ACCESSORIES
B Measures up to 3000 Amps AC
B Connects directly to an instrument
B Flexible head fits all, small conductors and large DKTA-620, Single to dual temperature adapter
bus-bars up to 7" in diameter
B Accessory
for multimeters and clamp-ons with temperature input
B Wide frequency bandwidth (10Hz to 20kHz)
B Converts
single temperature input to a dual temperature
B Computes differential temperature between probes
ACCESSORIES
AM-150 FA-15A/1000V and FA-1A/1000V FA-15A / 1000V; FA-1A / 1000V
AM-160 FA-15A/1000V and FA-1A/1000V FA-15A / 1000V; FA-1A / 1000V
B Converts the USB port of a personal computer to the RS-232
AM-220 5X20-250.5 F0.5 / 250V
B Supports Windows 95(OSR2X), 98, 2000, ME, XP Mac 8.6 and higher AM-240 5X20-250.5 F0.5 / 250V
B Works with Amprobe instruments with download capabilities AM-3 8AG361 F1A / 600V
B Works with many other products with USB ports, including AMB-1A 8AG361 F1A / 600V
cameras, palm pilot, card readers, mouse, security systems, etc. AMB-2 8AG361 F1A / 600V
B Will free up the serial port for other uses AMB-45 FA-0.5A/700V FA0.5A/700V
AU92 FP520 and FP540 F0.5A / 500V; F10A / 500V
CR50 FP125 F0.1A / 250V
TM-SWA, RS232 Cable and Software LCR55 FP125 F0.1A / 250V
DM7B FP450 F0.2A / 600V
B Allows for real-time data downloads from TMA10A and TMD90A DM9B FP175 F0.5A / 600V
B Records two channels simultaneously HD110C FP700 F2A / 1500VDC
HD160C FP700 F2A / 1500VDC
CAT III
Three-phase distribution, large building lighting systems, distribution panel devices
CAT II
Appliances, portable tools
CAT IV
Three-phase atutility connection, electricity meters, outside and service entrance
* Category ratings per EN 61010. Category boundaries may not be exact.
Disconnect Motor
480 V panel
000124
Adjustable
speed motor
Disconnect drive
Power .
factor .
correction
capacitors
Transfer
switch UPS PDU Servers
480 V/
Emergency 277 V
generator Lighting
Main panel
switchgear
Utility Ground 480 V
power system Copier
120 V/ Receptable
Transformer 208 V
panel