You are on page 1of 5

Required Reinforcement:

M
Ku
bd 2
M= 2300 kNm
b= 4500 mm
d= 434 mm
Ku= 2.714 392.6167

0.85bdf c ' ku
Asreq 1 1
fy 0.383 f c '
fy= 460 N/mm2
fc'= 45 N/mm2
Asreq= 13298 mm2
Asreq/m= 2955 mm2/m
= 0.681% OK

Cl.7.12.2.1
414
0.18%
fy
min= 0.162%
Asreq/m= 703 mm2/m
Punching Shear Checking Comply with ACI 318
fc' Concrete Cylinder Strength 35 N/mm2
d Effective depth 438 mm
c1 Width of Col. Measured in direction of Mu 1800 mm
c2 Width of Col. Measured to C1 1800 mm
b1 Width of Critical Perimeter measured in Mu c1+d 2238 mm
b2 Width of Critical Perimeter measured to b1 c2+d 2238 mm

ACI318:05 Cl.11.12.1.2
bo The Length of the critical perimeter 2(b1+b2) 8952 mm

ACI318:05 Cl.11.12.2.1
Ratio of Long side to Short side c2/c1 1

4
Vc1 11-33 2 f c 'b0 d 11574 kN

(2.952 N/mm2)
columns status i.e.: interior col., edge col. & corner col. interior
o 40 for interior, 30 for edge & 20 fpr corner 40

s
Vc2 11-34 2 f c 'b0 d 7633 kN
b0
(1.947 N/mm2)

Vc3 11-35 4 f c 'b0 d 7716 kN

(1.968 N/mm2)
Vc the smallest of 11-33, 11-34 & 11-35 min 7633 kN
(1.947 N/mm2)

ACI318:05 Cl.9.2.3.2.3
Reduction Factor of Shear and Torsion 0.75
Vc Shear capacity 5725 kN
(1.46 N/mm2)

w Applied factored pressure 68.9 kN/m2


l1 Shorter Span 9 m
l2 Longer Span 9 m
Vu factored applied shear force w (l1 l2 - b1 b2) 5236 kN
(1.335 N/mm2)

Vu < Vc Checking the shear capacity of shear Satisfactory


1d
bo The Length of the critical perimeter 2(b1+b2) 8952 mm
ACI318:08 Cl.11.12.3.1
Vc 2 f c 'b0 d 3858 kN
(0.984 N/mm2)
Vc Concrete Shear capacity 2893 kN
(0.738 N/mm2)

ACI318:08 Cl.11.5.7.2
Av f yt d
Vs 11-15 Steel Shear capacity Vu Vc 2342 kN
Sv
fyt Strength of reinforcement 460 N/mm2
Vs
Av Shear reinforcement 5092.1 mm2
f yt
Av
Shear reinforcement per mm 0.569 mm2/mm
Sv
Provide

2d
bo The Length of the critical perimeter 2(b1+b2) 10704 mm
ACI318:08 Cl.11.12.3.1
Vc 4613 kN
2 f c 'b0 d
(0.984 N/mm2)
Vc Concrete Shear capacity 3460 kN
(0.738 N/mm2)

ACI318:08 Cl.11.5.7.2
Av f yt d
Vs 11-15 Steel Shear capacity Vu Vc 1776 kN
Sv
Vs
Av Shear reinforcement 3861.0 mm2
f yt
Av
Shear reinforcement per mm 0.361 mm2/mm
Sv
Provide

3d
bo The Length of the critical perimeter 2(b1+b2) 12456 mm
ACI318:08 Cl.11.12.3.1
Vc 5368 kN
2 f c 'b0 d
(0.984 N/mm2)
Vc Concrete Shear capacity 4026 kN
(0.738 N/mm2)

ACI318:08 Cl.11.5.7.2
Av f yt d
Vs 11-15 Steel Shear capacity Vu Vc 1210 kN
Sv
Av
Vs
Shear reinforcement 2630.0 mm2
f yt
Av
Shear reinforcement per mm 0.211 mm2/mm
Sv
Av
Sv
Provide

4d
bo The Length of the critical perimeter 2(b1+b2) 14208 mm
ACI318:08 Cl.11.12.3.1
Vc 6123 kN
2 f c 'b0 d
(0.984 N/mm2)
Vc Concrete Shear capacity 4592 kN
(0.738 N/mm2)

ACI318:08 Cl.11.5.7.2
Av f yt d
Vs 11-15 Steel Shear capacity Vu Vc 644 kN
Sv
Vs
Av Shear reinforcement 1398.9 mm2
f yt
Av
Shear reinforcement per mm 0.098 mm2/mm
Sv
Provide

5d
bo The Length of the critical perimeter 2(b1+b2) 15960 mm
ACI318:08 Cl.11.12.3.1
Vc 6878 kN
2 f c 'b0 d
(0.984 N/mm2)
Vc Concrete Shear capacity 5159 kN
(0.738 N/mm2)

ACI318:08 Cl.11.5.7.2
Av f yt d
Vs 11-15 Steel Shear capacity Vu Vc 77 kN
Sv
Vs
Av Shear reinforcement 167.9 mm2
f yt
Av
Shear reinforcement per mm 0.011 mm2/mm
Sv
Provide

6d
bo The Length of the critical perimeter 2(b1+b2) 17712 mm
ACI318:08 Cl.11.12.3.1
Vc 7633 kN
2 f c 'b0 d
(0.984 N/mm2)
Vc Concrete Shear capacity 5725 kN
(0.738 N/mm2)

ACI318:08 Cl.11.5.7.2
Av f yt d
Vs 11-15 Steel Shear capacity Vu Vc -489 kN
Sv
Av
Vs
Shear reinforcement -1063.2 mm2
f yt
Av
Sv
Vs
f yt
Av
Shear reinforcement per mm -0.060 mm2/mm
Sv
Provide