You are on page 1of 12

Fazy

4 XPERT V - Series
AC V ariab le Frequency Drive

AMTECH ELECTRONICS (INDIA) LTD.


an ISO 9001 : 2008 COMPANY
a x p e r t E a z y User-Friendly
Easy to Install & Wire
The AX P ER T-E A ZY has been dow nsized considerably hence require less space to mount.
W ell-defined term inations fo r pow er and control circuit allows user to install and w ire the drive easily. Use of
term inals with captive screw s on the main control board fa cilitates single-handed installation.

Easy to Operate & Program


80-character, 4-line LCD display & 8-key keypad (HMI)
S elf-explanatory full param eter name is displayed on Digital O peration Panel fo r easy program m ing. This
allow s user to set param eters w ith o ut referring to the manual.
Navigation o f param eters made easy w ith self-explana tory functional keys like NORM, MODE, GROUP, UP &
DOW N, RUN & STOP fo r easy operation in local mode.
8 selectable param eters on single screen helps to m onitor critical param eters sim ultaneously.
Fault history with last ten faults and 8 im portant param eters helps in trouble shooting.

Easy to Control
Advanced control is easy and less expensive with configurable analog / digital I/O and integral PID.
Digital O peration Panel can be extended to 300 m eter (1000 ft) fo r rem ote operation through optional cable.
Easily configurable control m odes as per the application requirem ent.
User program m able 8-analog & 15 digital I/O's.
A xp ert C om m unicator drive support softw are fo r PC.

Easy to Economize
A uxiliary Drive feature allow s the user to control two different m otors with different HP and control schem es.
M ulti-pum p control feature allows the control o f 5 pumps with single drive which doesn't require PLC.
Built-In energy m eter displays all electrical param eters, which elim inates the need o f separate energy meter.
50C (122F) design, elim inates the need o f derating the drive.
Built-in PID, PLC and application specific softw are reduces the peripherals' cost.
Built-in energy saving calculator.
M odbus-R TU connectivity offered as a standard.
No option board required fo r encoder feedback.

Easy to Maintain
The cooling fan, one o f the com m on service parts can be easily rem oved fo r replacem ent.
Total C onductive Tim e and Total Run Time provides the inform ation about the drive and m achine usage fo r the
m onitoring o f serviceable parts.

Easy to Protect
The 32-bit High Speed Digital Signal P rocessor protects the drive against the short circuit or ground fault
conditions. User setable over load function protects the load against the over load conditions.
Soft stall current lim it reduces the output frequency if the output current exceeds the set level before the drive
trips. Input and O utput Phase Loss to prevent loading on the other phases.

3E PROUD
AC Drive by Design
Improved Efficiency, High Reliability & Unmatched Performance

Digital Operation Panel


U s e r S e le c t a b le
LC D D is p la y : 8 p a r a m e t e r D is p la y
80 c h a ra c te r, 4 L in e d is p la y o n S in g le S c r e e n
w ith b a c k lig h t

E a zy N a v ig a tio n th ro u g h
M O D E , N O R M , G R O U P,
F a u lt H is to ry w ith L ast UP, D O W N K ey s
Ten F a u lts w ith 8 D y n a m ic
P a ra m e te r's V a lu e s

Axpert-Communicator

Designed for Harsh Environments


Immune to Power Fluctuations

C us C i.Ypi ii Vi.jli.invi

M alice' F.jiiv-ml

sspODt No lo ro n c c

Mffle IfiTWlI
d
r,. i p ii i
" T ' i ;' ll1r r n
' ft H. Ioil '!*
1

T O O W N 2
Application Industries and Fields
Axpert-Eazy Series AC Drive is a perfect solution for soft start, speed regulation, energy saving and intelligent control of Induction Motor.
For demanding applications like crane (hoist), conveyor, stacker/reclaimer, centrifuge, etc... it delivers unmatched performance.

1 Typical application industries include :


Thermal power, Hydro power, Biomass
Forced draft fan Slurry pump Primary air Compressor
Feed water pump Cooling Tower fan Induced draft fan Coal mill
Secondary air fan Condensate pump Powder exhaust fan

Petroleum, Petrochemical, Natural gas


Pipeline transportation pump Water injection pump Feed water pump
Submerged pump Brine pump Compressor Pressure blower
Feed water pump for offshore oil platform

Coal mines & minerals


Descaling pump Mud pump Slurry pump Clean water pump
Feeding pump Stirring pump Kiln transmission Ventilation fan
Drainage pump Ball mill Conveyer Crusher

Steel & nonferrous metallurgy


Blast furnace blower Pusher car Induced draft fan Primary dust removal blower
Compressor Kneader Compressing blower Forced draft fan
Water-delivery pump Descaling pump Stacker/reclaimer Crane
Secondary dust removal blower

Cement & building materials


Kiln draft fan Kiln drive Rotary kiln transmission Stone crusher
Coal mill Dust removal fan Cooling fan

Municipal (heat supply, water supply, sewage etc.)


Pressure blower Induced draft fan Forced draft fan Pressure pump
Sewage pump Cleaning water pump Lifting pump Reclaimed water pump

Light industry, chemical industry


Gas blower Pressure pump Compressor Axial flow pump
Soft water pump Water-delivery pump

Pulp & Paper

Paper machine Paper winding Pulper machine Process fans & pumps

Sugar

Mill drive Cane carrier Juice pump aFiberizer a Leveler

Full range of functions for fans and pumps


Square law V/F function ensures high energy efficiency.
Built-In PID Control with Sleep Mode and variables can be assigned to real process units.
Speed Search allows the drive to start with rotating machinery without damage or tripping.
Power Loss Carry Through allows the uninterrupted operation of the machine up to 5 second power loss.
Under Current Level to prevent the machine from running idle.
Multi-pump control function.
Built-In Energy Meter and Energy saving calculator.
Reverse direction lock to inhibit the reverse direction start
Digital connections accept NPN or PNP (sink/source) to allow the use of existing and new sensors / PLC.

3
tV STAND ARD S P E C IF IC A T IO N S
Pow er S ource 380~480 VAC, 3-Phase, 3-Wire, 50/60 Hz
Tolerance Voltage tolerance: -15 to +10%, Frequency tolerance: +/-5%
AMT- - 4 037 045 055 075 090 110 132 160 200 250 315 355 400 450 500 630 710 800 900 11E 14E 15E 18E
Max Continuous Rated Current (A) Note 1 72 87 110 147 175 215 245 320 360 470 530 600 704 800 844 1067 1205 1440 1613 1992 2500 2700 3200
Heavy Normal
Duty

Max Applicable Motor (kW) Note 2 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 800 900 1120 1400 1550 1800
O v e r lo a d C u r r e n t R a t in g 120% for 60 seconds, 140% for 2.5 seconds every 5 minutes
Max Continuous Rated Current (A) Note 1 60 72 87 110 147 175 215 245 320 360 470 530 600 704 800 844 1067 1205 1440 1613 1992 2500 2700
Duty

Max Applicable Motor (kW) Note 2 30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 800 900 1120 1400 1500
O v e r lo a d C u r r e n t R a t in g 150% for 60 seconds, 175% fo r 2.5 seconds every 5 m inutes

Pow er S ource 500~575 VAC, 3-Phase, 3-Wire, 50/60 Hz


Tolerance Voltage tolerance: -15 to +10%, Frequency tolerance: +/-5%
AMT- - 5 037 045 055 075 090 110 132 160 200 250 315 355 400 450 500 630 710 900 10E 12E 14E 15E 18E
Max Continuous Rated Current (A) Note 1
Heavy Normal

54 73 87 110 135 150 175 215 290 345 390 430 485 540 670 720 950 1060 1335 1400 1680 1720 2050
Duty

Max Applicable Motor (kW) Note 2 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 900 1000 1250 1400 1550 1800
O v e r lo a d C u r r e n t R a t in g 120% for 60 seconds, 140% for 2.5 seconds every 5 minutes
Max Continuous Rated Current (A) Note 1 46 54 73 87 110 135 150 175 215 290 345 390 430 485 540 670 720 950 1060 1335 1400 1680 1720
Duty

Max Applicable Motor (kW) Note 2 30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 900 1000 1250 1400 1550
O v e r lo a d C u r r e n t R a t in g 150% for 60 seconds, 175% for 2.5 seconds every 5 minutes

Pow er S ource 600~690 VAC, 3-Phase, 3-Wire, 50/60 Hz


Tolerance Voltage tolerance: -15 to +10%, Frequency tolerance: +/-5%
AMT- - 6 037 045 055 075 0190 110 132 160 200 250 315 355 400 450 500 630 710 900 10E 12E 14E 17E 18E 21E
Max Continuous Rated Current (A) Note 1 46 54 72 87 110 135 150 175 215 290 345 387 426 482 537 662 713 941 1058 1327 1396 1680 1720 2050
Heavy Normal
Duty

Max Applicable Motor (kW) Note 2 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 630 710 900 1000 1250 1400 1700 1800 2100
O v e r lo a d C u r r e n t R a t in g 120% for 60 seconds, 140% for 2.5 seconds every 5 minutes
Max Continuous Rated Current (A) Note 1 37 46 54 72 87 110 135 15C 175 215 290 345 387 426 482 537 663 713 941 1058 1327 1396 1680 1860
Duty

Max Applicable Motor (kW) Note 2 30 37 45 55 75 90 110 132 160 200 250 315 355 400 450 500 63( 710 900 1000 1250 1400 1700 1800
O v e r lo a d C u r r e n t R a t in g 150% for 60 seconds, 175% for 2.5 seconds every 5 minutes
C o n tr o l M e th o d D ig it a l S p a c e V e c t o r P W M C o n t r o l

C o n tr o l M o d e V /F , C lo s e d lo o p V /F , S e n s o r le s s V e c t o r C o n t r o l, C lo s e d lo o p V e c t o r C o n t r o l

F re q u e n c y R a n g e 0 .1 ~ 6 0 0 H z f o r V /F C o n tr o l
F re q u e n c y A c c u ra c y D ig ita l r e fe r e n c e s : 0 .0 1 % ( 0 ~ 5 0 C ) / A n a lo g re fe r e n c e s : 0 .0 1 % ( 0 ~ 5 0 C )
Control Functions

O u t p u t F r e q u e n c y R e s o lu tio n 0 .0 0 0 1 H z ( 2 0 - b it)
F r e q u e n c y S e ttin g R e s o lu tio n 0 .0 1 H z D ig ita l, 0 .0 1 2 H z / 5 0 H z A n a lo g ( 1 2 - b it)
V / H z C h a r a c t e r is t ic s 2 - P r e p r o g r a m m e d p a tte r n s , 1 - C u s to m 3 - p o in t s e ttin g p a tte r n
T o rq u e B o o s t M a n u a l / A u t o m a t ic S e le c tiv e : 0 ~ 2 0 %
A c c e le r a t io n / D e c e le r a t io n T im e 0 . 1 ~ 6 ,0 0 , 0 0 0 S e c o n d s / L in e a r o r S - C u r v e s e le c tiv e
S k ip F r e q u e n c y T h r e e fr e q u e n c ie s c a n b e s e t, b a n d c a n b e s e t u p to 1 0 .0 H z
S lip C o m p e n s a t io n S lip c o m p e n s a t io n f r e q u e n c y u p to 5 .0 H z
C a r r ie r F r e q u e n c y Note3 D e fa u lt: 5 k H z , 2 ~ 1 0 k H z D e fa u lt: 4 k H z , 2 ~ 6 k H z
S p e e d S e a r c h F u n c tio n A llo w s th e d riv e to s t a r t w it h r o ta tin g m a c h in e r y w it h o u t d a m a g e / tr ip p in g .
B u m p le s s tr a n s f e r f o r r e d u n d a n c y a p p lic a t io n ( O p tio n a l)
P o w e r L o s s C a rry T h ro u g h U p to 5 s e c o n d s f o r s m o o t h o p e r a t io n o f th e s y s te m d u r in g p o w e r lo s s
D C B r a k in g D C B r a k in g s t a r t fr e q u e n c y 0 .1 ~ 5 0 H z , T im e : 0 ~ 2 5 s e c o n d s ,
S p e c ific a tio n s

B r a k e c u r r e n t: 1 5 to 1 5 0 %
F r e q u e n c y S e ttin g In p u t D ig ita l O p e r a tio n P a n e l ( K e y p a d )
P o te n tio m e te r : 2 k O h m
P r o g r a m m a b le A n a lo g In p u ts
S t a tic P o t: F r e q u e n c y I n c r e a s e / F r e q u e n c y D e c r e a s e u s in g d ig ita l in p u ts
P r e s e t S p e e d s : U s in g d ig ita l in p u ts P r e s e t in p u t- 0 , 1 & 2
S e ria l R S -4 8 5 , P LC A n a lo g O u tp u t - 1, 2, 3 & 4
Operation

T o r q u e S e ttin g In p u t D ig ita l O p e r a t io n P a n e l ( K e y p a d )
P o te n tio m e te r : 2 k O h m
P r o g r a m m a b le A n a lo g In p u ts
S t a t ic P o t: T o r q u e In c r e a s e /T o r q u e D e c r e a s e u s in g d ig ita l in p u ts
P r e s e t S p e e d s : U s in g d ig ita l in p u ts P r e s e t in p u t-0 , 1 & 2
P L C A n a lo g O u tp u t - 1, 2, 3 & 4
S e r ia l R S 4 8 5

4
STAND ARD S P E C IF IC A T IO N S
P rogram m able A na lo g Inputs FSV: 0~5 Vdc or 0~10 Vdc (or Inverse)
FSI: 0~20 mA or 4~20 mA (or Inverse)
VIN: 0~10 Vdc (or Inverse)
IIN: 0~20 mA or 4~20 mA (or Inverse)
D igital Inputs 8-Programmable Sequence Inputs, Sink / Source changeable
S p e c ific a tio n s

Programmable to 41 different options: Not Used, Jog Select, Ramp Select, Preset i/p-0,
Preset i/p-1, Preset i/p-2, Freq Increase, Freq Decrease, Aux Drive, Emergency Stop,
Fault Reset, Ext Fault, Reverse, Terminal, Ref Select 0, Ref Select 1, PR Step Skip, PR
Step Hold, PR/RSF Reset, PID Bypass, PID Disable, Emergency Stop-NC, Ext Fault-NC,
Run, Stop, Drive Enable-NC, Drive Enable-NO, PLC input 1~ 8 and Torque mode
D igital O utputs 4-Programmable Sequence Outputs, open collector type
O peration

Programmable to 36 different options: Not Used, Run, Local, Reverse Run, I-Detection,
Freq. Attain, Speed Detect1, Speed Detect2, Acceleration, Deceleration, Aux Drive, Timer
Output, Zero Speed, Fault Alarm, PID Up Limit, PID Lo Limit, Temp Alarm, Ready, Pump-
1~4, Doff-End Alarm, Sleep Mode, Fault, PLC Output 1~7, PID F/B Ulmt, PID F/B LLmt
P rogram m able A nalog O utputs 2-Programmable analog voltage outputs VO1 & VO2: 0~10 Vdc
2-Programmable analog current outputs IO1 & IO2: 4~20 mA
Programmable between 15 different options: Output Frequency, Output Current,
Output Power, Output Voltage, DC Bus Volt, PID Output, Heatsink temperature,PLC
Analog Output 1 to 4 Unipolar Torque Current, Excite Current, Set Frequency and
Bipolar Torque Current
P otential Free C ontacts 3-Programmable 1-NO, 1-NC for 2A @ 240 VAC
relays: Programmable between 34 different options same as digital outputs
N etw ork con n ectivity RS-485 for PC Interface with Modbus-RTU protocol as standard
A u to R estart Adjustable up to 10 times for ten faults
PID C ontrolle r Inbuilt PID can be used as stand alone
D isplay and Keypad unit Total 80-Character, 4-Line LCD panel with backlit, 8-Key keypad, 3-Status
Indicating LED for Run, Stop and Fault
Display

Simultaneous display of eight selectable monitor parameters from Output


Frequency, RPM, Current, % Current, Set Frequency, PID Reference,
PID Feed Back, Input Voltage R-Y, Input Voltage Y-B, Output Voltage,
DC Bus Voltage, kW, kWH, MWH, Heatsink Temperature in C and F
P rotective Function Current limit, Over Current Fault, Timed Over Current Fault, Load side Short Circuit Fault,
Protective Specification

Under Current Fault, DC Bus Over Voltage Fault, DC Bus Under Voltage Fault,
Temperature Fault, Output Phase Loss Fault, Earth (Ground) Fault, External Fault,
Charging Fault, Current Sensor Fail Fault, EEPROM Fault, 4~20mA Reference Missing
Fault, Auto Tuning Fault, Emergency Stop, Communication Loss, Output Unbalance
Current Fault.
S m ooth O peration Speed Search, Auto Restart and Power Loss Carry through functions,
Heat sink over temperature alarm
Fault H istory Last ten faults with status and eight operational parameters like Output Frequency,
Output Current, Dc Bus Voltage, Heat Sink Temperature, Input Voltage,
Total ON Time, kWH and MWH
Installation Location Indoor
V ibration As per EN 60068-2-6, Acceleration: 1 g, Frequency: 10 Hz ~ 150 Hz
Environment

A m b ie n t Tem perature 0~50 C (32~122 F) for 400V series drives and for 500V/600V series HD ratings
0~40 C (32~104 f ) for 500V/600V series ND ratings, contact Amtech for more details.
S torage Tem perature -20~70 C (-4~158 F)
A ltitu d e (above sea level) 1000 m (3300 ft) without derating, above this derate 3% per 305 m (1000 ft)
H um idity 0~95% maximum non-condensing
E nclosure 1 IP00 (Standard IP20 or higher protection optional)
The input power factor is approximately 0.9 with 3% ACL / The inverter efficiency will be >98%
Consult Amtech for models other than mentioned in this catalog.
N otel : Indicates the total effective value including the higher harmonics.
Note2 : The maximum applicable motor output is given for a standard induction motor.
Note3 : If the default carrier frequency is exceeded, derate the output current by 5% per 1kHz as the reduced rating. The default carrier frequency for 500 V &
600 V series drives is 4 kHz and can be adjustable between 2~6 kHz.

5
EXTER N A L D IM E N S IO N FOR 4 0 0 V SERIES
Dim ensions in mm (inch) W e ig h t
in
A B C D E F G H L J 0 K kg (lb)
AMT-011-4, -015-4, -018-4 -022-4
470 250 262 196.5 438.5 61.5 81 61.5 15 10 18
-
(18.5) (9.8) (10.3) (7.7) (17.2) (2.4) (3.2) (2.4) (0.59) (0.39) (39.7)
AMT-030-4, -037-4, -045-4, -055-4
585 250 300 196.5 565 61.5 186 61.5 10 10 31
-
(23.0) (9.8) (11.8) (7.7) (22.2) (2.4) (7.3) (2.4) (0.39) (0.39) (68.3)
AMT-075-4, -090-4
700 322 365 217 680 98 145 98 10 11 45
(14.4) (26.8) (5.7) (3.9) - (0.43) (99.2)
(27.6) (12.7) (8.5) (3.9) (0.39)
AMT-110-4, -132-4, -160-4
970 360 364 305 940 127 238 106 15 11 76
(38.2) (14.2) (14.3) (12.0) (37.0) (0.59) - (0.43)
(5.0) (9.4) (4.2) (167.6)
AMT-200-4, -250-4
1185 481 321 400 1155 167 431 187 15 200 11 103
(46.6) (18.9) (12.6) (15.7) (45.5) (6.6) (17.0) (7.4) (0.59) (7.87) (0.43) (227.0)

AMT-315-4, -355-4
1330 506 321 400 1300 155 528 224 15 200 11 138
(52.4) (19.9) (12.6) (15.7) (51.2) (6.1) (20.8) (8.8) (0.59) (7.87) (0.43) (304.2)

AMT-200-4-P, -250-4-P
1085 468 326 186 839 181 587 160.5 15 176 11 89
(42.7) (18.4) (12.8) (7.3) (33.0) (7.11) (23.1) (6.32) (0.59) (6.93) (0.43) (196.2)
AMT-315-4-P, -355-4-P
1185 478 351 186 940 175.5 687 175.5 15 186 11 99
(46.6) (18.7) (13.8) (7.3) (37.0) (6.9) (27.05) (6.9) (0.59) (7.3) (0.43) (218.2)

AMT-400-4 ~ AMT-18E-4, consult Amtech for detail dimensions


AMT-800 and above rating uses Diode Unit (DU) / Inverter Unit (IU) paralleling technology

FOR 5 0 0 V & 6 0 0 V SERIES


Dim ensions in mm (inch) W e ig h t
in
A B C D E F G H L J 0 K kg (lb)
CD

-015-5, -018-5 -022-5, -030-5


tH
> >

o
7 I

-015-6, -018-6 -022-6, -030-6, -037-6


CD
o

595 292 300 236.5 574.5 84 142.5 81 10 10 22


-
(23.4) (11.5) (11.8) (9.3) (22.6) (3.3) (5.6) (3.1) (0.39) (0.39) (48.5)
AMT-037-5, -045-5, -055-5
AMT-045-6, -055-6, -075-6
679.5 292 300 236.5 659.5 84 227.5 81 10 10 28.5
-
(26.7) (11.5) (11.8) (9.3) (26.0) (3.3) (9.0) (3.1) (0.39) (0.39) (62.8)
AMT-075-5, -090-5, -110-5
AMT-090-6, -110-6, -132-6
906 368.5 364.5 313 876 121 375 119 15 11 65
(35.7) (14.5) (14.8) -
(14.3) (12.3) (34.5) (4.8) (4.7) (0.59) (0.43) (143.3)
AMT-132-5, -160-5
AMT-160-6, -200-6
970 360 364 255 940 127 236.5 105.5 15 11 77.4
(38.2) (14.2) (14.3) (10.0) (37.0) (4.2) (0.59) - (0.43)
(5.0) (9.3) (170.6)
AMT-200-5, -250-5, -315-5
AMT-250-6, -315-6, -355-6
1247 506 321 400 1217 154.5 460 224.5 15 200 11 117.7
(49.0) (19.9) (12.6) (15.7) (47.9) (6.0) (18.1) (8.8) (0.59) (7.87) (0.43) (259.4)
AMT-200-5-P, -250-5-P, -315-5-P
AMT-250-6-P, -315-6-P, -355-6-P
1185 478 351 186 940 175.5 687 175.5 15 186 11 102
(46.6) (18.7) (13.8) (7.3) (37.0) (6.9) (27.05) (6.9) (0.59) (7.3) (0.43) (224.8)

For AMT-355-5 ~ AMT-18E-5, AMT-400-6 ~ AMT-21E-6, consult Amtech for detail dimensions
AMT-710-5, -900-6 and above rating uses Diode Unit (DU) / Inverter Unit (IU) paralleling
technology

6
tV C O N N E C T IO N A N D T E R M IN A LS

SINK LOGIC SOURCE LOGIC


+24V
+24V
+24V

PSI

PSI
L<50m
COM (164)

L<50m
(164) JP1 JP1
DCL
O
R
b
SINK
SOURCE
SINK
SOURCE
Y Y j
DB UNIT
o E

MCCB
Power Supply

Control block
P15 15V
K +
FSV 33kW [S. 270W VO1
0-10V Analog Ref CZh- ^ Output Frequency
(0-10V, 1mA)
0V 10kW r \ ^ 270W
Analog COM VO2 Output Current
PROGRAMMABLE (0-10V, 1mA) PROGRAMMABLE
ANALOG FSI 0V
4-20mA Analog Ref Analog COM ANALOG
INPUT
LI 270W OUTPUT
VIN 33kW 50 W IO1 Motor Power
0-10V PID Feedback
q X (4-20mA)

3:
|10kW
r. 50W
0V IO2 Motor Voltage
Analog COM
(4-20mA)
IIN
4-20mA Analog input
270W PSO1
PSO2
PSO3 . Programmable
RUN >Sequence Outputs
PSO4
STOP COM

PSI6 TX s RS-485
.R X
+24V COM

PB
COM
PBN
SEQUENCE PSI1 Encoder
PA Connections
INPUT
PAN
PSI2
+5V
COM
PSI3

PSI4
FC I Fault Relay
FB [ 240V AC, 1A
PSI5
R1A
COM Programmable

_J\
R1C - Relay 1
240V AC, 1A
R2A
CANH R2C
\
Programmable
- >Relay 2
R2B _ J 240V AC, 1A
CANH
AXPERT-EAZY NC

Control term inals


(The term inal block are aligned in two rows.) TB1
P15 0V VIN IIN VO2 I01 CANH RUN PSI6 COM PSI2 PSI4 +24V PSO1 PSO3 COM RX PB PA +5V

FSV FSI 0V V01 0V I02 CANL STOP +24V PSI1 PSI3 PSI5 COM PSO2 PSO4 TX COM PBN PAN COM

7 Note-1 : This circuit is valid upto AMT- 055 - 4. Above this, DCL comes before soft charge circuit.
IN P U T / O U T P U T T E R M IN A L F U N C T IO N

SYMBOL NAME USE

+24V +24V source This source is used for the Programmable Sequence Inputs. The logic for the
Programmable Sequence Inputs can be changed to sink or source with the help of JP1
COM on the control board.

RUN RUN command This is programmable sequence input and can be configured to different 41 functions
using C114.

STOP STOP command This is programmable sequence input and can be configured to different 41 functions
using C115.

PSI1-6 Programmable These are programmable sequence inputs and can be configured to
Sequence different 36 functions using C101 ~ C106.
Inputs 1 ~ 6

PSO1-4 Programmable These are programmable sequence outputs different 36 functions using
Sequence C107 ~ C110.
Outputs 1 ~ 4

P15 +15V source This is a 10V source used when a frequency setter is connected to the FSV input
circuit. The frequency setter to be used should be a variable resistor of 2k and 2W.

0V Common This is a common terminal for analog input signals.

FS V Frequency This is mainly used for setting the frequency (speed) input. A maximum frequency
Setting Voltage setting is available at 10V input. This setting is valid when FSV 0-10V, FSV 0-5V, FSV
input 10-0V or FSV 5-0V is selected as frequency reference input in A 106 or D204 or torque
reference input in A 108. Also, this input can be configured as PID Reference input
(C603) or PID Feedback input (C604) or Math Reference Input2 (A702) or Variable bias
(A706) for math operation.

FSI Frequency This is mainly used for setting the frequency (speed) input. A maximum frequency
Setting setting is available at 20mA input. This setting is valid when FSI 0-20mA, FSI 4-20mA,
Current input FSI 20-0mA or FSI 20-4mA is selected as frequency reference input in A106 or D204 or
torque reference input in A 108 . Also, this input can be configured as PID Reference
input (C603) or PID Feedback input (C604) or Math Reference Input2 (A702) or
Variable bias (A706) for math operation.

VIN Voltage input This is mainly used for setting the frequency (speed) input. A maximum frequency
setting is available at 10V input. This setting is valid when VIN 0-10V is selected as
frequency reference input in A 106 . Also, this input can be configured as PID Reference
input (C603) or PID Feedback input (C604) or Math Reference Input2 (A702) or
Variable bias (A706) for math operation.

IIN Current Input This is mainly used for setting the frequency (speed) input. A maximum frequency
setting is available at 20m A input. This setting is valid when IIN 4-20mA is selected as
frequency reference input in A 106 . Also, this input can be configured as PID Reference
input (C603) or PID Feedback input (C604) or Math Reference Input2 (A702) or
Variable bias (A706) for math operation.

VO1 Vout-1 These are programmable analog voltage outputs 0-10V. In default condition, output
frequency signal is assigned to VO1 and output current signal is assigned to VO2.
VO2 Vout-2 Different seven internal signals can be assigned to these outputs using C201 & C202.

IO1 Iout-1 These are programmable analog current outputs 4-20mA. In default condition, motor
power signal is assigned to IO1 and output voltage signal is assigned to IO2. Different
IO2 Iout-2 seven internal signals can be assigned to these outputs using C203 & C204.

TX DATA+ These two signals are for the two-wire RS-485 serial link. The protocol used is
Modbus-RTU.
RX DATA-
i
tv IN P U T / O U T P U T T E R M IN A L F U N C T IO N

SYMBOL NAME USE

PA A-Phase Pulses The A-phase positive pulse of encoder is applied at this terminal.

PAN The A-phase negative pulse of encoder is applied at this terminal.

PB B-Phase Pulses The B-phase positive pulse of encoder is applied at this terminal.

PBN The B-phase negative pulse of encoder is applied at this terminal.

+5V +5V source This is +5V source for the encoder. The encoder is required only in case of close loop
control mode. Refer chapter-10 for details on encoder specification.

FA Fault Relay These contacts function when a fault occurs (when the FAULT LED is flashing on
Contacts Digital Operation Panel). When a fault occurs, the section FA-FC is closed and the
FC section FB-FC is open. It can be configured to different 36 functions using C113.

FB

R1A Programmable This is programmable relay and its function is assigned to Run condition in default.
Relay 1 contacts When a programmed condition occurs, the section R1A-R1C is closed and the section
R1C R1B-R1C is open. It can be configured to different 36 functions using C111.

R1B

R2A Programmable This is programmable relay and its function is not assigned to any internal signal in
Relay 2 contacts default. When any function is assigned using C112 and the programmed condition
R2C occurs, the section R2A-R2C is closed and the section R2B-R2C is open. It can be
configured to different 36 functions using C112.
R2B

1^ SY STEM O P TIO N S

T y p e s o f o p tio n s

O ption classificatio n E a zy D rive S o ftw a re (PC )


Line reactor (ACL) / DC choke (DCL) AXPERT COMMUNICATOR
Noise filter - Powerful monitoring and control software for PC for controlling
DBU / DBR unit maximum drives at a time.
Output reactor / Output sine filter F u n ctio n s
12 / 18-pulse converter for low harmonic requirements
- All parameter reading / writing & monitoring
Active Front-end Converter to meet IEEE 519 - Bargraphs
requirements and regenerative applications - Trend plots
Cabinets / Panels with different IP rating - Alarm view
9
IUSER S E LE C T A B LE F U N C T IO N S
PID Control Auxiliary Drive Motor Control

C 6 0 8 : P ID d e v ia tio n
C 6 1 0 : P ID O f f s e t U p p e r L im it
A d ju s tm e n t

r
C 602=1
_ 1_
C 6 0 3 : P ID +
R e f e r e n c e In p u t
PID - PID Output

C 6 0 4 : P ID
C 6 0 9 : P ID d e v ia tio n
F e e d b a c k In p u t
L o w e r L im it

C 6 0 5 : P r o p o r tio n a l G a in 1
C 6 0 6 : In te g r a l T im e -
C 607 D e r i v a t i v e G a in -

PID Controller

Multi-pump Control PLCT & Speed Search Function


AXPERT EAZY AC DRIVE

Pattern Run Function & RSF Auto Restart

< _ r

PC Software - AXPERT COMMUNICATOR Math Operation

M u lt ip lie r

A 1 0 6 : F r e q R e f In p u t

In te r n a l F re q
C om m and

A 7 0 2 : M a th R e f In p u t

10
OUR OTHER OFFERINGS
MOTION CONTROL AUTOMATION POWER QUALITY INDUSTRIAL ELECTRONICS

AUTOMATION. ONE STOP SOLUTION YOUR TECHNOLOGY


DRIVE FOR SUC CESS
MADE EASY TO QUALITY POW ER PARTNER

We provide complete motion Automation made Easy is our A mt ech' s Power Quality We offer technology solutions
control system solutions or philosophy to simplify the Solutions offer you the synergy to independent R&D labs as
individual system components increasing complexity of of multiple benefits - energy well as industrial segments,
to address industry specific modern production systems c o n s e r v a t i o n , e nha n ced like Traction, Renewable
requirements and optimize through our AMTECH JETTER operational efficiency and Energy sources (Wind, Solar
your process. PROCESS PLC Technology reliability through a dedicated etc.) thereby zeroing your lead
platform. r a nge of p r o d u c t s and time to commercialization.
Our solutions are simple, services.
compatible and environment We simplify the contradictory
friendly, resulting in efficient imperatives in modern auto Products
production, cost optimization mation to provide simplistic but Products Traction Drive
and m i n i m i z i n g hu man cost effective customized Passive Harmonic Filter High Voltage Power Supply
intervention. It even leads to solutions. Active Harmonic Filter Battery back-up drive &
energy conservation especially
in t y p i c a l Fan, B l o w e r Harmonic Reactor systems for critical loads
Flagship Solutions
applications. Static Harmonic Converter Wind Power Converter
NANO, DELTA, MIKRO,
EMI/RFI Filter Solar Inverter
JETWEB, JETVIEW, HMI &
Flagship Solutions SCADA, SERVO & AXES Sinus Filter
AXPERT-EAZY AC Drive CONTROL SYSTEM Active Front end Converter Services
AXPERT-VT240S AC Drive Retrofit Solutions
AXPERT-HIVERT Medium Applications Services Customized solutions for
Voltage Drive Paper Machine Automation Harmonic Audit and industry specific
AXPERT-OPTI torque Soft Solutions to comply with applications
Textiles Manufacturing
Starter IEEE-519 standard Solution for Oil, Gas &
Packaging
AXPERT-EAZY HF-High System design, Mining
Winder Machine
Frequency Drive optimization & pay-back Power Electronics
Crane & Material Handling analysis Technology outsourcing
Equipment

: A E IL /E A Z Y /0 2 -1 7
Applications Consultancy for Power
CNC Machines Quality improvement
Fans, Blowers, pumps
Semiconductor Assembly Training on Power Quality
Compressors, Centrifuges line Management
Agitators & Conveyors Retrofit solutions Energy Audit and solutions
Oil & Gas by experienced BEE .N O .

Mining certified professionals


CAT

L A M T E C H
AMTECH ELECTRONICS (INDIA) LTD.
DRIVE FOR SUCCESS
E-6, GIDC Electronics Zone, Gandhinagar - 382028, Gujarat, India.
Phone: +91-79-23289101, 23289102, 23289103 | Fax: +91-79-23289111
Email: info@amtechelectronics.com | Website: www.amtechelectronics.com
Specifications in this catalog are subject to change w ithout notice.