You are on page 1of 1

FOOTING TYPE COLUMN NO'S BbXBb BtXBt Dt De STEEL IN EACH DIRECTION

(BOTTOM)
F1 TYPE-1 D.C 4'0"X4'0" 4'0"X4'0" 18" 9" #12MM @ 6" C/C
F2 TYPE-1 C8,C11 4'6"X6'6" 2'0"X4'0" 21" 9" #12MM @ 5" C/C
F3 TYPE-1 C7 4'6"X7'6" 2'0"X5'0" 24" 9" #12MM @ 4" C/C
F4 TYPE-1 C10 5'6"X7'6" 3'0"X4'6" 24" 9" #12MM @4" C/C
F5 TYPE-2 C1 7'6"X7'6" ------------ 27" ----- #12MM @3" C/C
Bt
Bb Bt
Bb Bt X X

Dt

PDF created with pdfFactory Pro trial version www.pdffactory.com


X X

Dt
De

6"
6"
P.C.C.
P.C.C. Bt Bb
Bt Bb Bb SECTION X - X
Bb SECTION X - X PLAN
PLAN
TYPE-1 TYPE-2
PROJECT: ARCHITECT:
NOTES: 6. SBC of soil is taken as 150 kN/Sq. M. . PLACE: STRUCTURAL CONSULTANT:
1. Use M20 grade of concrete for footngs GUNTUR
2. Grade of steel shall be Fe500 conforming to
7. 6" Thick P.C.C.BED
8. This drawing shall be read in conjunction with MR. MADAN MOHAN
SCALE: NOT TO SCALE
IS:1786-1984 & it's amendments. relevant architectural drawings.
TITLE: DRAWN BY: VISHNU PRADEEP.K P VISHNU SAI
3. Provide lap length in reinforcing bar 9. Do not scale this drawing, FOOTING DETAILS. MSc Structural Engineer(UK),AMIE
for footings shall be 57. Only written dimensions are to be followed. CHECKED BY:
EMAIL: pvs0096@gmail.com
4. Clear cover for mainreinforcement for 10. All dimensions shall be verified by the REV. NO: DESCRIPTION: REV. BY DATE
PHONE: 9908044100
footings 50mm,
5. All dimensions are in FEETS and INCHES.
site engineer before execution. SHEET.NO: 1 17-05-17.