J857Cr (According with GB E8515-G, Corresponding with

AWS 12015-G)

Introduction: J857Cr is a kind of low-alloy high strength steel electrode with low-
hydrogen natrium type coating. DCRP (Direct Current Reversed Polarity). All-position
welding.

Uses: Used for welding pressure vessels made of low-alloy high strength steel with tensile
strength of about 830MPa and some other structures, such as 14CrMnMoVB, 30CrMo,
35CrMo, etc.

Chemical Composition of Deposited Metal (%)


Chemical Composition C Mn Si S P Mo Cr V
Guarantee Value 0.15 1.00 0.60 0.035 0.035 0.50~1.00 0.7~1.00 0.05~0.15
General Result 0.10 ~1.60 0.40 0.020 0.020 ~0.60 ~0.80 ~0.05

Mechanical Properties of Deposited Metal


Test Item Rm(MPa) ReLRp0.2(Mpa) A(%) KV2(J)
Guarantee Value 830 740 12 (normal temperature)
General Result 860~950 750 12~18 27

Diffusible Hydrogen Content in Deposited Metal: 5.0ml/100g(Chromatography or


Mercury Method)

X-ray Radiographic Inspection: Degree

Reference Current (DC+)


Electrode Diameter(mm) 2.5 3.2 4.0 5.0
Welding Current (A) 60~90 80~110 130~170 160~200

Instructions:

1.The electrodes must be baked under 350-400 for an hour before


welding, put into a 100-150 insulation can and taken as soon as they are
needed.

2. The stains on the weldments like rust must be cleared away, and the
weldments must be preheated to about 200.

3.Weldments can be tempered under 600-650 after welding so as to


eliminate internal stress.
J757Ni
(According with GB E7515-G,
Corresponding with AWS E11015-G)

Introduction: J757Ni is a kind of low-alloy high strength steel electrode


with low-hydrogen natrium type coating. The deposited metal has
excellent mechanical properties, and especially higher low temperature
impact toughness and excellent crack-resistance.

Uses: Mainly used for steel at corresponding strength grade, such as


14MnMoNbB, WEL-TEN80, etc.

Chemical Composition of Deposited Metal (%)


Chemical
C Mn Si S P Ni Mo Cr
Composition
Guarantee
0.10 1.00 0.60 0.030 0.030 2.00~2.60 0.40~0.70 0.20
Value

Mechanical Properties of Deposited Metal


Test Item Rm(MPa) ReLRp0.2(Mpa) A(%) KV2(J)
Guarantee Value 740 640 13 27(-40)
General Result 820 690 22 88

Diffusible Hydrogen Content in Deposited Metal:


4.0ml/100g(Glycerine Hydrogen Test)

X-ray Radiographic Inspection: Degree

Reference Current (DC+)


Electrode Diameter(mm) 2.5 3.2 4.0 5.0
Welding Current (A) 60~90 80~130 140~180 180~240

Instructions:
1.The electrodes must be baked under about
350-380 for an hour before welding, and
used as soon as baking is completed.
2.The stains on the weldments, such as rust,
oil stains, moisture, etc., must be cleared
away before welding.
3.When welding, short arc must be used and
stringer bead is suitable.