You are on page 1of 47

Presentation: Yes

Submission : Yes

Next generation PASOLINK

iPASOLINK100/200/400/1000

2011/11/22 ver.14

For customers name


Page 3 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: No
Yes

Revision History Submission : No


Yes

Ver. Date Change


1.0 2010/06/24 First Version
9.0 2011/04/06 ATM PWE/aggregation are deleted (pending function) (Page 10,16,17 & 25).
R2(10GbE and CWDM) of iPASO1000 is changed to R3.(Page 10,20,21 & 22)
10.0 2011/06/06 MSTP and ERP (Ethernet Ring Protection ) to be supported by iPASO100/200.(Page10)
ODU compatibility with CPV ODU(NEO/c) is added. (Page 36)
IHG ODU compatibility with NEO IDC is added (Page 36)
The description of soft-key is revised (Page37-42 )
OHP for NEO/c Air-compatibility is deleted due to release pending.
11.0 2011/10/07 E1 cross connect CH number is modified & 4/8 Class QoS is added. (Page 10,11,12,16,17,21)
iPASO1000 Layout
L t explanation
l ti isi modified.
difi d (Page
(P 21)
CWDM card is added. (Page 22,23,24,25,33,34)
Radio link throughput value is modified (Page 27)
Huawei 980 is added. (Page 8,38)
Comparison is modified. (Page 39)
iPASOLINK compatibility with NHP ODU is added(Page41)
Soft-key information is updated. (Page 44,45,46)
12.0 2011/10/28 Slot position of the MSE card is added. (Page 21 )

13.0 2011/11/14 512QAM modulation is added for iPASO400/1000(Page6,10,16,17,20,21,26,28)


Higher modulation presentation page is added(Page27)
Hardware and Software configuration for 512Q is added.(Page43)
Soft-key for 512QAM is added.(Page48,49)
Soft-key for Main Card redundancy is added(Page50)
14.0 2011/11/22 Description, parameter and figure of 512QAM is modified (Page 28,31)
Description of QoS mechanism is modified (Page29)
512QAM modulation is added in XPIC (Page30 )
iPASO1000 layout is modified (Page35)

For customers name


Page 4 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Positioning of iPASOLINK in Mobile Backhaul Submission : Yes

Access Aggregation Metro Core


2G
3G
iPASO100/200 iPASO200 BSC/RNC aGW

iPASO1000 iPASO1000
2G iPASO1000

3G iPASO400
iPASO1000
iPASO1000
LTE
iPASO200 iPASO400 iPASO1000 iPASO1000

Wireless TDM Wireless Ethernet


Wired TDM Wired Ethernet

Capacity
iPASOLINK 1000
12-wayy Nodal
Redundancy
High Speed INTF
iPASOLINK 400 SDH and All IP
with CWDM
12-way
iPASOLINK 100/200
4-way Nodal
4-way Redundancy
Pay as grow architecture
Compact
p packet
p radio
1-way/2-way 2-way radio (iPASO200)
Redundancy (iPASO200) Domain
For customers name
Page 5 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK
Submission : Yes
- Next Generation Packet Radio -

Converged
C dP
Packet
k tR
Radio
di ffor LTE & N
Nextt G
Generation
ti B
Backhaul
kh l
Designed for:
Optimised, scalable and high capacity link throughput
Transmission over both Microwave and Optical
Carrier grade migration from TDM legacy to full IP Backhaul iPASOLINK 100/200
Application flexibility and software upgradeability

Feature rich and highly compact


Full packet radio with scalable throughput capability
iPASOLINK 400
Hitless AMR up to 256/512QAM with adaptive QoS
TDM and Ethernet ring support
Full range of synchronization (TDM, Sync Eth)
Multi-service support with PWE and aggregation
Ethernet OAM, upgradeable to MPLS and IP transport
Wide range of interfaces: E1, STM-1, FE, GbE iPASOLINK 1000

. Released 2011 2012


iPASOLINK 200 Capacity Optimised Packet Radio for the extension
off reach
h and
d capacity
it
iPASOLINK 100 Capacity Optimised Compact Packet Radio for tail
iPASOLINK 400 Intelligent Nodal Solution for traffic aggregation
and bandwidth management
iPASOLINK 1000
Intelligent Node for Wireless and Optical network
iPASOLINK Roadmap integration and Core Network handover

For customers name


Page 6 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK Radio Transmission Method Submission : Yes

1) TDM Radio Stratex Eclipse

MUX
TDM(E1)

MUX
TDM TDM(E1)
Ethernet IP over E1 IP over E1 Ethernet

2) Hybrid Radio (Native Ethernet + Native TDM) NEO, Ceragon IP-10, HW RTN Hybrid Ver.

TDM(E1) TDM TDM(E1)


Ethernet Ethernet
Ethernet

3) Packet Radio ALU MPR, HW RTN Packet Ver.


Ethernet
PWE

SW
TDM(E1) PWE TDM(E1)
SW

Ethernet Ethernet

4) Hybrid + Packet Radio iPASOLINK

PWE

SW
TDM(E1) PWE Ethernet TDM(E1)
SW
W

Ethernett
Eth Ethernet
TDM(E1) TDM(E1)
TDM
For customers name
Page 7 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Comparison of the Service Coverage Submission : No


Yes

TDM ((Ethernet Native Native Packet Radio


Over TDM) TDM Ethernet (PWE, Sync)

SDH PDH Sync PWE


NEO

iPASOLINK 100/200/400/1000

Huawei RTN905

Huawei RTN910/950/980(TDM*)

Huawei RTN910/950/980(Hybrid*)

*Main board(950) and Modem card is different Huawei RTN910/950/980(Packet*)


RTN910/950/980(Packet )
ALU 9500MPR

Dragon. Horizon

C
Ceragon IP
IP-10
10
SIAE AL pulus2

Stratex Eclipse Stratex Eclipse Packet Node** (plug-in)


**2Gbps throughput only
Ericsson Minilink-TN (Modem D/H)

For customers name


Page 8 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK capability for Evolution of Mobile Backhaul


Submission : Yes

TDM based Backhaul


2/3G Backhaul

TDM Based
BSC/ RNC
Network
BS

Option-1 Option-2
TDM + IP based Backhaul ALL IP based Backhaul

2/3G/LTE Backhaul 2/3G/LTE Backhaul

TDM Based BSC/


BSC/ RNC PWE PWE TDM Core
Network RNC
BS BS IP Based
Network
IP Based MME MME
Network S-GW S-GW
eNB eNB

Only iPASOLINK can make these transitions on the same platform


For customers name
Page 9 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK Series Functionalities Summary Submission : Yes

iPASOLINK 100 iPASOLINK 200 iPASOLINK 400 iPASOLINK 1000


Operation Frequency 6/7/8/10/11/13/15/18/23/26/28/32/38/42 GHz

Modulation QPSK/16/32/64/128/256 QAM QPSK/16/32/64/128/256/512 QAM

Radio Nodal capability One Way Two way 4 Way 12 Way

Main Board 16xE1 + 2xFE (or 4xGbE) 16xE1 + 2xFE (or 2xGbE)
+ 2xGbE(SFP Slots) + 2xGbE(SFP Slots) 4xGbE

Interfaces 16xE1 card


16xE1 card chSTM-1 with APS option card
O ti
Optional
l chSTM-1
hSTM 1 card
d 4xGbE card (RJ-45x2
(RJ 45x2 + SFPx2)
MSE card (16xE1 TDM PWE) MSE card (64xE1 TDM PWE)
CWDM card
10GbE card (for iPASOLINK 1000 future plan )

Packet Switching Capacity 20 Gbps 40 Gbps 48 Gbps

Port based & Tag based VLAN


Ethernet Functionality CoS/ ToS/ Diffserv/ MPLS EXP based Priority Control
4/8 Class QoS
Strict priority, D-WRR with Bandwidth Management
Policing with CIR/EIR

Synchronization Synchronous Ethernet


IEEE 1588v2
TDM Cross-Connect E1 Cross-Connect with ADM for Radio and chSTM-1
TDM SW Capacity 152 x 152 E1ch 168 x 168 E1
Radio Protection - HS/HS,HS/SD,FD
Packet RSTP, MSTP, ERPS
Resiliency
TDM E1 SNCP with Radio Ring
Ethernet OAM IEEE 802.1ag Service OAM and ITU-T Y.1731 PM

Other Functions - XPIC(1+0,1+1) , Traffic Aggregation

For customers name


Page 10 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK 100 features overview Submission : Yes

iPASOLINK100 - High Performance Tail solution


1U single board, all-in-one model
16xE1,, 2xFE (or
( 4xGbE)) and 2xGbE(SFP)
( ) ports
p
One AMR Modems are equipped on single main board
Configurable by Software Key.
Additional sub-board slots are available for 16E1, STM-1 or PWE.
SNCP TDM ring and LAG for Ethernet
Full TDM to Full IP
Built-in TDM Cross-Connect(152E1x152E1)
( ) and Power-full Packet Switch
Enhanced system gain with new ODU(IHG)
Ether OAM, Sync ETH

For customers name


Page 11 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK 200 features overview Submission : Yes

iPASOLINK200 - High Performance Tail and Repeater solution


1U single board, all-in-one model
16xE1,, 2xFE (or
( 4xGbE)) and 2xGbE(SFP)
( ) ports
p
2 AMR Modems are equipped on single main board.
Configurable as 1+0, 1+1, 2+0 and 1+0 XPIC, by Software Key.
Additional sub-board slots are available for 16E1, STM-1 or PWE.
SNCP TDM ring and LAG for Ethernet
Full TDM to Full IP
Built-in TDM Cross-Connect(152E1x152E1)
( ) and Power-full Packet Switch
Enhanced system gain with new ODU(IHG)
Ether OAM, Sync ETH

For customers name


Page 12 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
iPASOLINK100/200
Presentation: Yes
Submission : Yes

Equipment Layout and Configuration Options


Optional card slot (Mounted on main board)
16E1
ODU interface Channelized STM-1
iPASO100: 1 port LCT/NMS 2xFE or 4xGbE AUX
Multi service engine (TDM/PWE)
iPASO200: 2 ports (option) (DI/DO
Option))

1U

SFP 16xE1 Power Supply Fan unit


LED
Indication USB (GbE) ALM/ (Option:
(status/alarm) Memory DSC Second power
Slot inlet)

2 x FE (Electrical) on the main board is set as default. By software key, it can be


changed into 4 x GbE (10/100/1000Base-T)
2xSFP(GbE) can be set either Optically or Electrically. Same SFP type is required.
LCT/NMS interface has NE 1 and NE2. These interfaces are to be used
for IDU-IDU back-to-back stacking.
AUX interface can be used e.g. for taking in alarms of air-conditioners, doors etc.
Sync ETH Clock module will be mounted onto the main board for Sync ETH,
Sync. ETH chSTM
chSTM-11 etc
etc..

For customers name


Page 13 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: No
Yes

iPASOLINK100/200 details Submission : No


Yes

1. Configuration

Optical S-1.1
STM1-S SFP Optical L-1.1
1000BASE-SX
Electrical
1000BASE-LX 2) CLK
CLK-2MC
2MC option
STM1-S
1000BASE-T CLK-2MC card is installed on the
Blank Cover AUX-S 16E1-S PS-S main board.
Option Interface-2 Option Interface-1 Option Interface-3
IDU Port-5 & 6 SFP

iPASOLINK 200

16 x E1 FAN-C
4 x ETH
IDU Port-14

iPASOLINK 100 *CLK-2MC card is necessary for E1 SNCP, Sync


ETH, 1588v2, chSTM-1 and external clock for
transfer the clock information.
This card is common for iPASOLINK400/1000.
One ODU interface

2.Options
1) Needs to remove top cover to install optional cards

For customers name


Page 14 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: No
Yes

iPASOLINK 100/200 STM-1 card Submission : No


Yes

Without Option

STM-1 B
STM-1 SFP STM-1 Transparent
U
S

With Soft-key Option

Soft-key : MUX/DEMUX STM-1


STM-1
B
SFP MUX/DEMUX U Channelized STM-1

63xE1
S

For customers name


Page 15 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK 400 features overview Submission : Yes

iPASOLINK400 Flexible Converged Node for tail or 4way Nodal


1U with main card and 4 universal slots model.
Main card with 16E1,
16E1 2xFE and 2 GbE (SFP).
(SFP)
Flexible 512QAM AMR modem configuration, 1+0, 2 to 4+0, 2x (1+1),
2x (1+0 XPIC) , 1x(1+1 XPIC), and modem-less optical node.
Various Interface Card type
yp
16E1 card, 4xGE card, MSE card (for TDM PWE), STM-1 card
Converged Node for Wireless/Optical
Full TDM to Full IP
Built in TDM Cross-Connect(168E1x168E1) and Power-full Packet Switch
Enhanced system gain with new ODU(IHG)
ETH OAM,, Sync
y Ether

For customers name


Page 16 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
iPASOLINK400
Presentation: Yes
Submission : Yes

Equipment Layout and Configuration Options

Universal Universal Universal Universal


Slot #1 Slot #2 Slot #3 Slot #4

1U

USB ALM/ Power Supply F unit


Fan i
LCT/NMS SFPx2 16xE1
Memory /FE *(or GbE)x2 DSC/ (Option: Second PS)
Slot NMS

*FE1 interface is used for FE (or GbE) or NE1. NE1 interface to be used for IDU-IDU back-to-back connection.

Universal Slot Card Variation


Modem (QPSK/16/32/64/128/256/512QAM, 7/14/28/56MHz)
16E1 TDM interface
i t f with
ith digital
di it l cross connectt (168E1 x 168E1)
Multi-service engine for PWE3 interface (TDM PWE)
This function is available as the combination of nxE1 interface cards)
STM-1 interface with 63E1 ADM function (electrical/optical, SFP), ASP supported as an option.
4xGbE interface(2xRJ45+2xSFP)
( )
AUX card for ALM/EOW/DSC
(Sync. ETH Clock module will be mounted onto the main card.)

For customers name


Page 17 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: No
Yes

iPASOLINK 400/1000 STM-1 card (1) Submission : No


Yes

Without Option

STM-1
STM-1 SFP

B
2 x STM-1 Transparent
U
STM-1
STM-1 SFP
S

With Soft-key
y Option
p ((1))

STM-1
STM-1 SFP
B
APS U 1 x STM-1 Transparent
S
STM-1 SFP

S ft k
Soft-key: APS

For customers name


Page 18 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: No
Yes

iPASOLINK 400/1000 STM-1 card (2) Submission : No


Yes

With Soft-key
S ft k O Option
ti (2)

Soft-key: MUX/DEMUX

B
STM-1 SFP MUX/DEMUX U
Channelized STM-1
S
63xE1

STM-1 SFP

With Soft-key
y Option
p ((3))

Soft-key: MUX/DEMUX
STM-1 SFP
B
APS MUX/DEMUX U Channelized STM-1
S
STM-1 SFP 63xE1

S ft k
Soft-key: APS

For customers name


Page 19 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK 1000 features overview Submission : Yes

Design Concept;
3U with 12 way Nordal Radio with 512QAM modems
Redundant Main card (TDM/L2 Switch matrix with CPU)
10GbE and CWDM Metro Network interface
10GbE,
Metro Ethernet Upgradable (i.e. MPLS-TP)
Multi way Nodal Radio
Satisfy most Nodal Node requirements
Full
F ll C
Compatible
tibl with
ith iPASOLINK400 modems
d
Intelligent Converged Node
Gateway for High Speed Optical Metro Network for LTE
Higher capacity optical network interface at Metro side.
CWDM
10 GbE (Future Plan)
Provides upgradable interoperability with Core Network
Independent handling of Native traffic
TDM with SNCP Ring
Carrier Class L2 switching with Ether Ring and 10GbE for Packet Traffic.
Scalable SW capacity from Multi-way nodal to Metro Optical node.

For customers name


Page 20 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
iPASOLINK1000
Presentation: Yes
Submission : Yes

Equipment Layout and Configuration Options


(1) (2) (3) (4)
(5) (6) (7) (8)

3U (9) MAIN CARD

(10) MAIN CARD (Opt)

(11) (12) (13) (14)


TERM PS PS (Opt)

NMS NE1 Power USB LCT GbEx2 SFPx2 ALM/ Optional Fan unit
Supply Memory DSC PS
Slot ( ): Slot#

Universal Card Variation and Slot location(1-14)


Modem (QPSK/16/32/64/128/256/512QAM, 7/14/28/56MHz) (Slot 1 to 8 and 11 to 14)
16E1 TDM interface
i t f with
ith digital
di it l cross connectt (168E1 x 168E1) (Slot
(Sl t 1 to
t 14)
Multi-service engine for PWE3 interface (TDM PWE) (Slot 11)
This function is available as the combination of nxE1 interface cards)
STM-1 interface with 63E1 ADM function (electrical/optical, SFP) (Slot 1 to 14)
4xGbE interface(2xRJ45+2xSFP)
( ) (Slot
( 9 and 10. Two card p
per IDU))
AUX card for ALM/EOW/DSC (Slot 8 and 14 only. One card per IDU)
(Sync. ETH Clock module will be mounted onto the main card.)

For customers name


Page 21 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Scalable Modular Architecture - Universal Slot - Submission : Yes

Universal
U i Slots
l Sl t
400 series Universal Interface CardModem/INTFC) can be
mounted on Universal Interface Slot
4 Universal Card Slots
Universal Interface Slot
MODEM card

MODEM
INTFC card
16E1 4xGbE

STM-1
etc.
1000 series Multi-function card
MSE
14 Universal Card Slots CWDM
CWDM card

CWDM (* iPASO1000 only)

Main Card (Not a common card)


MAIN INTFC
CPU / Main SW (L2/TDM) / CLK
LCT/NMS Port / ALM

High Speed Interface Slot (future)

10 GbE

Term Slot
NMS port

For customers name


Page 22 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK1000 CWDM
Submission : Yes

iPASOLINK supports single fiber bidirectional


transmission feature using passive CWDM filter and 8CWDM-MB

colored SFP. This capability can minimize number of IN OUT IN OUT IN OUT IN OUT CWDM

fibers to be required. Several interface including GbE,


CWDM Card
10GbE, and STM-1 are supported.
CWDM Grid is based on ITU-T 20nm.
CWDM Filter Grid 1 2 3 4 5 6 7 8
Center Wavelength 1471.0 1491.0 1511.0 1531.0 1551.0 1571.0 1591.0 1611.0

Number of wavelength :8
Number of client channels : 4
CWDM interface 0.55
Colored STM-1
Colored GbE 0.45
Colored 10GbE (future)
Loss dB//km
iPASOLINK1000
0.35

ve

ve

GbE GbE

GbE
8 wavelengths in single fiber GbE 0.25

STM-1
STM 1 STM-1
STM 1
Passiv

Passiv


STM-1 STM-1
0.15
1200 1300 1400 1500 1600 1700
Wavelength nm
For customers name
Page 23 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

CWDM Model (Cable Connection Example)


Submission : Yes

Colored SFP (for GbE INF card, STM-1 INF card)


GbE Colored SFP
STM-1 Colored SFP
CWDM Card
Slot-In type card for universal slot (CWDM passive filter)
! MODEM
PWR/MD
TX/
ODU
-A
! MODEM
PWR/MD
TX/ODU
-A
! MODEM
PWR/MD
-A
TX/ODU
! MODEM
PWR/MD
TX/ODU
-A FAN-M
RX/RST RX/RST RX/RST RX/RST

GbE Card IF IN ?XIF-OUTMD PWR IF IN ?XIF-OUTMD PWR IF IN ?XIF-OUTMD PWR IF IN ?XIF-OUTMD PWR
! MODEM
PWR/MD
TX/
ODU
-A
! MODEM
PWR/MD
-A
TX/
ODU
! MODEM
PWR/MD
TX/
ODU
-A
! MODEM
PWR/MD
TX/ODU
-A
RX/RST RX/RST RX/RST RX/RST
IF IN ?XIF-OUTMD PWR IF IN ?XIF-OUTMD PWR IF IN ?XIF-OUTMD PWR IF IN ?XIF-OUTMD PWR
OUT IN OUT IN GbE-A NECiPASOLINK OUT IN OUT IN MC-M
2 4
1 3 PROTECT CALL ALM
ALM EOW
1 2 3 4 ONLINE IDU MAINT MEM LCT 1 2 3 4 ALM/SC/CLK
OUT IN OUT IN
2 4
GbE-A NECiPASOLINK OUT IN OUT IN MC-M FAN-M
1 3 PROTECT CALL
ALM EOW
1 2 3 4 ONLINE IDU MAINT
MEM LCT 1 2 3 4 ALM/SC/CLK
CWDM Card 8CWDM-MB
STM1-A
BLNK BLNK
OUT IN OUT IN
ONLINE ONLINE
IN OUT IN OUT IN OUT IN OUT CWDM ALM
1 2
TERM
-M -48V G PS-M -48V G PS-M
ALM
ALM PWR1 PWR1
NMS NE1 SC SELV SELV

STM-1 Card

There are two type of CWDM cards (Type MA, Type MB)
4 Pair (ch1-4)
8CWDM-MA CWDM Card
8CWDM MB
8CWDM-MB
1470nm
1490nm
1510nm
1530nm CWDM
FILTER
1550nm A B
1570nm Single
Si l
1590nm Fiber
1610nm
Single Fiber
For customers name
Page 24 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

CWDM Compatibility (iPASOLINK1000 & Transmode)


Submission : Yes

There are following compatibilities between iPASOLINK1000 and Transmode.


- Same wavelength
- Same SFP
- Same NMS Platform
- E2E OAM iPASO
Single fiber
TM

- MPLS-TP Interoperability (future)

iPASO TM TM
Si l fib
Single fiber Wavelength
0.55

Colored 0.45

s dB/km
SFP/SFP+
0.35

Loss
0.25

0.15
1200 1300 1400 1500 1600 1700
Wavelength nm

CWDM C
Card
d Transmode
CWDM
8 -MB

INOUTINOUTINOUTINOUT
CWDM
iPASOLINK1000
! PWR /MD
MODEM-A ! MODEM-A
PWR /MD ! MODEM-A
PWR /MD ! MODEM-A
PWR /MD
FAN-M
TX /ODU TX /ODU TX /ODU TX /ODU
RX /RST RX /RST RX /RST RX /RST
IF IN ? XIF- OUT MD PWR IF IN ? XIF- OUT MD PWR IF IN ? XIF- OUT MD PWR IF IN ? XIF- OUT MD PWR
! PWR /MD
MODEM-A ! MODEM-A
PWR /MD ! MODEM-A
PWR /MD ! MODEM-A
PWR /MD
TX /ODU TX /ODU TX /ODU TX /ODU
RX /RST RX /RST RX /RST RX /RST
IF IN ? XIF- OUT MD PWR IF IN ? XIF- OUT MD PWR IF IN ? XIF- OUT MD PWR IF IN ? XIF- OUT MD PWR
OUT IN OUT IN GbE-A NEC iPASOLINK OUT IN OUT IN MC-M
2 4 PROTECT CALL ALM
1 3
ALM EOW
1 2 3 4 ONLINE IDU MAINT MEM LCT 1 2 3 4 ALM/SC
/ /CLK
OUT IN OUT IN GbE-A NEC iPASOLINK OUT IN OUT IN MC-M FAN-M
2 4
1 3
PROTECT CALL
ALM EOW
1 2 3 4 ONLINE IDU MAINT MEM LCT 1 2 3 4 ALM/SC/CLK
8CWDM
-MB STM1-A
OUT IN OUT IN

ONLINE ONLINE BLNK BLNK


ALM
IN OUT IN OUT IN OUT IN OUT CWDM 1 2
TERM-M -48V G PS-M -48V G PS-M
ALM

ALM PWR1 PWR1


NMS NE1 SC SELV SELV

For customers name


Page 25 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Enhanced Radio Performances with new ODU (IHG)


Submission : Yes

Advanced Technologies and Superb Performance


High Modulation scheme for native Ethernet and 100
native TDM transmission with high spectrum
Enhanced System Gain
efficiency achieved by 256/512 QAM and by dual (256QAM/56MH )
(256QAM/56MHz)
90

S y s te m G a in (d B )
polarization transmission technologies.
AMR Function with hitless modulation switchover.
80
High System Gain
High System Gain achieved by Low Density Parity 70
Check (LDPC) Forward Error Correction (FEC)
technology and distortion cancelling technique 60
called linearizer allowing smaller antennas and
reducing platform
f cost.
50
Frequency Agility and Easy Tuning 6 7 10 13 15 18 23 26 32 38
Field tunable to your licensed radio frequency
channel within sub
sub-band
band through Web based LCT. Frequncy(GHz)

NEO HP with NHG2 iPASOLINK with IHG

For customers name


Page 26 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Higher Modulation Support Submission : Yes

Small-cell deployment Macro-cell deployment


Less than 200m radius ~500m to several km
The higher modulation link has a limitation for (urban, data density in radius
its link distance to achieve the link availability area)

(i.e.
(i e 99.999%).
99 999%) However,
However because NEC NECss LDPC
coding structure enables to get the higher
system gain, 512QAM will also be feasible for
LTE micro/small cell network.

LTE Network Image

Hop Length Sample iPASOLINK


Antenna size 0.6m
100.000%
%

99.999%

99.998%

99.997%

99.996%
abilty

99 995%
99.995%
Availa

99.994% 15 GHz QPSK 28MHz 42 mm/h


15 GHz 16QAM 28MHz 42 mm/h
99.993% 15 GHz 32QAM 28MHz 42 mm/h
15 GHz 64QAM 28MHz 42 mm/h
99.992%
15 GHz 128QAM 28MHz 42 mm/h 512QAM Constellation
99.991% 15 GHz 256QAM 28MHz 42 mm/h
15 GHz 512QAM 28MHz 42 mm/h
99.990%
0 5 10 15 20 25 30
HopLength (Km)

For customers name


Page 27 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Expanded AMR functionality


Submission : Yes

AMR is a technology to
improve robustness mainly in Mod [QAM] 512 256
128 128 256
512
64
the packet transmission 64
32
16 4PSK 16
32

environment by utilizing
thermal threshold difference Throughput
[Mbps] 257 229 200 172 143 114 57 114 143 172 200 229 257
between modulation hierarchy at 28 MHz BW

such as QPSK and 512 QAM.


Time
On the fine day, the operator
can get the 257Mbps Available Modulation and Channel Separation
throughput over the link which CS*
Mode 1 Mode 2 Mode 3 Mode 4
is designed for 57Mbps 7 MHz* 14 MHz* 28 MHz* 56 MHz*
Modulation
throughput as illustrated in the
figure. QPSK 14 Mbps 28 Mbps 57 Mbps 114 Mbps
16 QAM 28 Mbps 57 Mbps 114 Mbps 230 Mbps
iPASOLINK supports hitless 32 QAM 35 Mbps 71 Mbps 143 Mbps 287 Mbps
Adaptive Modulation from 64 QAM 42 Mbps 85 Mbps 172 Mbps 345 Mbps
QPSK to 512QAM and 128 QAM 49 Mbps 99 Mbps 200 Mbps 402 Mbps
achieves more than 500Mbps 256 QAM 56 Mbps 114 Mbps 229 Mbps 460 Mbps
in 56MHz.
56MHz 512 QAM - - 257 Mbps 515 Mbps
*: Channel Separation -: Understudy
Note: Maximum throughput at 64 byte-passed rate based.
For customers name
Page 28 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Advanced iPASOLINK QoS mechanism


Submission : No
Yes

IPASOLINK supports both Ingress Policer and Egress QoS functions.


Ingress Policer function;
MEF/RFC4115 compliant Ingress policing:
- CIR (Committed information Rate) and EIR (Excess information rate)
- Two-Rate
T R t Th
Three-Color
C l Marking
M ki

Egress 4/8 Class QoS function( previous stage of adaptive modulation);


Per-class queuing with strict priority (SP) and deficit round robin mechanism (DWRR).
- Limits maximum rate by per-queue basis, works with port shaper.
- Weighted tail drop or Weighted Random Early Detection (WRED) congestion
avoidance
id mechanism
h i workk with
ith colors.
l (Colored
(C l d by
b policing
li i in
i the
th ingress
i stage.)
t )
- Various Scheduling mode: 4Que (4SP, SP+3DWRR, 4DWRR) / 8Que (8SP, SP+7DWRR, 2SP+6DWRR)

Egress Queue
Determine
ete e
Internal I
Ingress Policer
P li
priority Scheduling
Class7
Token ( EIR) and
VLAN CoS
IPv4 precedence Queue Shaping
Shaper
IPv4/v6 DSCP
MPLS EXP
Class6
Strict
Priority
TDM
Token
k
bucket Queue
Port
Shaper
+
Shaper
Pack
Drop et
DWRR
QoS
Class0
Two-Rate (EIR,CIR),
Three-Color Marking Queue
G
Green : Under
U d CIR Shaper

Yellow : Over CIR & WRED Start Threshold (start


Under EIR to drop yellow packet)
Red: Over EIR

For customers name


Page 29 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK XPIC (Cross Polarization Interference Canceller)


Submission : Yes

iPASOLINK can double its transmission capacity up to 1030Mbps at 512QAM


and 920Mbps at 256QAM in 56MHz bandwidth by adopting NECs state of the
art XPIC technology.
The additional required
q components
p for XPIC are;
Dual polarized antenna,
Additional ODU,
Associated IF cable kit,
Soft-key
y upgrade
g in IDU.
iPASOLINK400 can be configured 2 pair of XPIC links with one IDU.

(In case of iPASOLINK200, no cable connection is required at the front panel for XPIC )

For customers name


Page 30 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Double the capacity with same IDU Submission : Yes

Single configuration

515MB
515Mbps ODU ODU 515Mbps

iPASOLINK 400 56MHz iPASOLINK 400


IDU
IDU

515Mbps 515Mbps

Same IDU doubles Link Capacity.

XPIC with ETH Traffic Aggregation configuration


XPIC (1 CH)
ODU ODU
515MB
1Gbps 1Gbps
515MB
ODU ODU
56MHz
iPASOLINK 400 iPASOLINK 400
IDU IDU
V
1Gbps 1Gbps
H

(Throughput is based on 56MHZ/512QAM/64Byte)


For customers name
Page 31 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Example of network configuration with iPASOLINK Submission : Yes

1) E1 with Ethernet Transmission


Aggregation
Access

16E1/MDR x 2 or
Channelized STM-1
16xE1
16xE1 FE or GbE
16 E1
16xE1 32xE1

Ethernet

2) STM-1 with Ethernet transmission

STM-1 STM-1
FE or GbE FE or GbE
STM-1 transparent

Ethernet

For customers name


Page 32 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Easy Link Extension by 2way IDU Submission : Yes

New site
Traditional way

Just ODU and Antenna make new link

New site
New way

No additional IDU
No
No additional rack space
No external cables It makes CAPEX down
No cable wiring works around 20%
For customers name
Page 33 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Radio and Optical convergence with CWDM


Submission : Yes

STM-1/E1

*10GbE/GbE x n

Wavelength multiplexing with


Native transmission is available
with CWDM technique
technique.

One Optical Fiber

*10GbE is future plan.

For customers name


Page 34 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Configuration Example : 7-way Converged Nodal


Submission : Yes

7-way7-way
Converged
NodalNodal

ANT2

ANT3 ANT1

Single fiber
ANT4 (STM-1&
iPASOLINK 1000
GbE) INTEGRATED PLATFORM &
TDM Switch HIGH RELIABILITY
ANT5
CWD
CWD
PWE STM-1
DM
DM

-
MODEM -
MODEM -
MODEM -
MODEM
ANT6 GbE -
MODEM -
MODEM -
MODEM - FAN
Packet Switch
-
4xGbE Main Card w/ 4GbE
ANT7 - Main Card- w/ 4GbE
MSE
- CWDM
- 2xSTM1
- 16xE1
- FAN
TERM PS PS
E1 FE/GbE
For Main Card redundancy
and the additional GbE interface

For customers name


Page 35 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Risk free migration to All IP Submission : Yes

The migration from TDM based network to All IP network is achieved


by simply adding the MSE (Multi Service Engine) card.

Hybrid Radio

16xE1

Migration
Packet Radio
(PWE)
MSE

16xE1
Note: Network needs to be synchronized by sync ETH , etc. MSE: Multi Service Engine
For customers name
Page 36 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Flexible PWE configuration Submission : Yes

iPASOLINK can configure PWE at both access site and aggregation site.
It allows operator easy configuration of the network.
Initial Configuration
Access Aggregation

core

E1/TDM

1) PWE at Access site


Access Aggregation

core
or PWE

E1/TDM E1/Ethernet

2) PWE at Aggregation site


Access Aggregation

core
PWE

E1/TDM
E1/Ethernet

For customers name


Page 37 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes
Submission : No
Yes

iPASOLINK Competitive Analysis

For customers name


Page 38 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Detailed competitive analysis


Submission : No
Yes

V d
Vender W kP
Weak Point
i t
Ceragon Not a Packet Radio (PWE is not available in the IDU.)
Huawei No common platform (Packet version and Hybrid version is different hardware. )
ALU No Native TDM ((Announcement of TDM mode,, but air link is still packet)
p )
SIAE Not a Packet Radio (PWE is not available in the IDU)
Stratex Not a Hybrid Radio. (Plug-in Packet radio function on the legacy TDM radio.)
NEC Ceragon Huawei Alcatel SIAE Stratex ZTE
iPASO iPASO iPASO RTN 9500MPR AL Packet
IP-10 RTN905 NR8250
1000 400 200 910/950/980 MSS-4/8 Plus2 Nodal
One Platform
Hybrid ( Native Ethernet & TDM) *1 *2
Packet Radio (PWE Inside)
Radio Link 256QAM
AMR

Only iPASOLINK series supports both Hybrid


QoS
One Box Nordal
VLAN
QoS/Diffserve
10 way 4 way




2way





2way 2/6/14way 2/6way 2wayx3 4way










6way

and Packet radio on the single platform from


Policer/Shaper
E1 >64xE1 48xE1 32xE1 32xE1 16xE1 nx42xE1 16xE1 32xE1 ?
Air E1 capacity >75xE1 >75xE1 >75xE1 75xE1 75xE1 75xE1 80xE1 100xE1 ?

access network to the core network


BB Interface GbE
10GbE
STM-1
CWDM
All IP PWE(E1)
Synch. SyncEther
OAM Ethernet OAM
Hot Standby(1+1)
Link RF Link Aggregation
E1 SNCP
Protection
RSTP
Ethernet Ring(G.8032)
*1: Different main board(950/980) and modems.
*2: Base function is TDM.
For customers name
Page 39 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

iPASOLINK and Others (LME/ALU/Huawei/Ceragon)


Submission : No
Yes

All in One (IP/OPT/MW)


Native TDM Nodal 10way Nodal
-iPASO 200 PWE inside
-iPASO 400 iPASO 200 iPASO 400 iPASO 1000 Native IP Packet Universal Slot
-iPASO 1000 (2 way) (4 way) (12 way)
(PWE) Ready for Metro

Legacy TDM
Native TDM Nodal
No Native IP, No PWE
-MiniLink TN(2P)
TN (2P) TN (6P)
20P Nodal
-MiniLink TN(6P)
-MiniLink TN(20P) TN (20P) Native IP (but poor Packet Handling)
-OMS1410
OMS1410 OMS 1410 ATM Aggregation

No Native TDM
(6way)
-9500 MPR (-e) 9500MPR 9500MPR 9500MPR Separate box (77xx)
(Half size) MSS-4 MSS-8
-MPT All Outdoor ODU (MPT)
Native IP Packet
-7705 SAR MPT
7705 SAR-M (PWE) Strong
St IP/MPLS(77xx)
IP/MPLS(77 )
(Outdoor) 7705 SAR-8

No big Nodal (planed)


Native TDM (6way) No Compatibility
-RTN6xx RTN 910 RTN 950 (with legacy RTN600)
-RTN9xx
RTN9xx
Native IP Packet Combination with PTN
-PTN9xx
PTN 950 PTN 1900 (PWE) Strong IP/MPLS(PTN)
-PTN1900

Native TDM No Nodal (just stacked)


Fib Ai IP M
FibeAir Max
No
o strong
st o g IP feature
eatu e
-FibeAir
Fib Ai IP Max
M
-IP 10 No Metro solution
Native IP No Redundancy
IP 10 (Stacked Nodal)

For customers name


Page 40 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: No
Yes
Submission : No
Yes

iPASOLINK Compatibility

For customers name


Page 41 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: No
Yes

iPASOLINK ODU Compatibility Submission : No


Yes

ODU Compatibility
Standard Power ODU High Power ODU

CPV NHG NHG2 IHG*1 NHP

NEO OK OK OK OK OK

NEO HP - Limited*2 OK OK OK

iPASOLINK*4 OK Limited*3 OK OK OK

*1 IHG: New Standard Power ODU for iPASOLINK series.


*2 Limited: Limited available frequency(10.5/23/38/6/7/18GHz) and functions
(no 256QAM & no 56MHz at 6-11GHz).
*3 Limited: Limited available frequency and functions ).
)
(no 256QAM & no 56MHz at 6-11GHz).
*4 NEO ODU compatibility soft-key is required.

For customers name


Page 42 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: No
Yes

Note for iPASOLINK400 512QAM Operation Submission : No


Yes

The 512QAM Operation is available with following configuration.


The combination of IHG ODU and iPASOLINK 400 IDU manufactured
after December 2011 are not necessary to update hardware and software
to support 512QAM modulation.

Version Manufacturing or
release date
IHG ODU Hardware xxDx ~ 2011/12 ~ (Note 1)
(2011/12 ~)
Firmware 5.08 ~
iPASO MODEM-A Hardware 2.00 ~ 2011/06 ~ (Note 2)
400 FPGA 1.23 ~ (2011/8/M ~ )

IDU Parameter 6.0 ~ (2011/10/B ~ )

2011/10/M ~
MC-A4 Firmware 2.02.29 ~
Software key High Modulation Should be set
(512QAM) ON
ON

Note 1) The IHG ODU (manufactured before November 2011) hardware update is available at Factory.
(The update tool at outside of the factory is under preparation, it will be available on March 2012)
2) Modem Hardware should be version 2.00 or later.

For customers name


Page 43 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes
Submission : Yes

iPASOLINK Soft-key System

For customers name


Page 44 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Serial Number for Soft-key


Submission : Yes

The following serial number is necessary 1) iPASOLINK 100/200


to order the upgrade soft-key.
These serial numbers can be obtained Name
from the inventory list of the LCT or NMS Plate

Serial Number of IDU Units


(not a serial Number of main board)

2) iPASOLINK 400

Serial Number of Main Card


(not a serial number of IDU units)

3) iPASOLINK 1000

Serial Number of TERM-M Card


((not a serial number of IDU units or
main card)

For customers name


Page 45 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Soft-key Parameters for iPASOLINK 100 Submission : Yes

The Soft-key in blue letter to be covered in the future version.

Radio Common Key


Radio Bit Rate (Fixed, Free or AMR)
NEO ODU(NHG/NHG2) Compatibility.
Radio Capacity Key
Radio Capacity per on-line modem (10/20/50/100/150/200/300/400Mbps)
ETH & TDM Key
RJ45 Port Usage in main board(2xFE or 2xFE+2xGbE or 4xGbE)
SFP Port Usage in main board
LAG and LACP for Ethernet Line (in Future)
Ethernet OAM(CC/LT/LB)
Ethernet OAM(LM/DM)
QoS
Q S Classify
Cl if (4 or 8 level)
l l)
Ethernet Ring Protection
E1 SNCP : Clock module is necessary
STM-1 MUX/DEMUX : STM-1 card and Clock module are necessary
Advanced Key
Sync ETH Clock (in Future) : Clock module is necessary
IEEE 1588v2 PTP clock : (in Future) Clock module is necessary

Note: Radio Redundancy(1+1), Radio Traffic Aggregation and XPIC key is not available for iPASO100.

For customers name


Page 46 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Soft-key Parameters for iPASOLINK 200 Submission : Yes

The Soft-key in blue letter to be covered in the future version.

Radio Common Key


Radio Redundancy (1+1) : for 1+1 HS and 1+1 TP
Radio Traffic Aggregation
Radio Bit Rate (Fixed, Free or AMR)
XPIC
NEO ODU((NHG/NHG2)) Compatibility
p y.
Radio Capacity Key
Radio Capacity per on-line modem (10/20/50/100/150/200/300/400Mbps)
ETH & TDM Key
RJ45 Port Usage in main board(2xFE or 2xFE+2xGbE or 4xGbE)
SFP Port Usage in main board
LAG andd LACP for
f Ethernet
Eth t Line
Li
Ethernet OAM(CC/LT/LB)
Ethernet OAM(LM/DM)
QoS Classify (4 or 8 level)
Ethernet Ring Protection
E1 SNCP : Clock module is necessary
STM-1 MUX/DEMUX : STM-1 card and Clock module are necessary
Advanced Key
Sync ETH Clock : Clock module is necessary
IEEE 1588v2 PTP clock : (in Future) Clock module is necessary

For customers name


Page 47 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Soft-key Parameters for iPASOLINK 400 Submission : Yes

Th S
The Soft-key
ft k iin bl
blue lletter
tt tto b
be covered
d iin th
the ffuture
t version.
i

System & Radio Key


Radio Redundancy (1+1) per modem pair : for 1+1 HS and 1+1 TP
Radio Traffic Aggregation
Radio Bit Rate (Fixed,
(Fixed Free or AMR)
XPIC per modem pair
NEO ODU(NHG/NHG2) Compatibility
High Modulation (512QAM)
Radio Capacity Key
Radio Capacity y per on-line modem ((10/20/50/100/150/200/300/400Mbps))
ETH & TDM Key
RJ45 Port Usage in main board(2xFE or 2xGbE)
SFP Port Usage in main board
VLAN table(256 or 4094 VLAN)
QoS Classify (4 or 8 class)
LAG and LACP for Ethernet Line
Ethernet Ring Protection
Ethernet OAM(CC/LT/LB)
Ethernet OAM(LM/DM)
E1 SNCP : Clock module is necessary
STM-1 APS Protection : STM-1 card is necessary
STM-1 MUX/DEMUX : STM-1 card and Clock module are necessary y
SFP Port Usage per optional card (per card)
Advanced Key
Sync ETH Clock : Clock module is necessary
IEEE 1588v2 PTP clock (in Future) : Clock module is necessary
Additional PWE E1 channels (per 16E1 up to 64E1) : MSE card is necessary

For customers name


Page 48 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx
Presentation: Yes

Soft-key Parameters for iPASOLINK 1000 Submission : Yes

Th S
The Soft-key
ft k iin bl
blue lletter
tt tto b
be covered
d iin th
the ffuture
t version.
i

System & Radio Key


Radio Redundancy (1+1) per modem pair : for 1+1 HS and 1+1 TP
ETH Traffic Aggregation
Radio Bit Rate (Fixed, Free or AMR)
XPIC per modem pair
NEO ODU(NHG/NHG2) Compatibility
High Modulation (512QAM) (in Future)
Radio Capacity Key
Radio Capacity per on-line modem (10/20/50/100/150/200/300/400Mbps)
ETH & TDM Key y
RJ45 Port Usage in main board(2xFE or 2xGbE)
SFP Port Usage in main board
QoS Classify (4 or 8 level)
VLAN table(256 or 4094 VLAN)
LAG and LACP for Ethernet Line
Ethernet Ringg Protection
Ethernet OAM(CC/LT/LB)
Ethernet OAM(LM/DM)
E1 SNCP : Clock module is necessary
STM-1 APS Protection : STM-1 card is necessary
STM-1 MUX/DEMUX : STM-1 card and Clock module are necessary
SFP Port Usageg pper optional
p card (p
(per card))
Advanced Key
Sync ETH Clock : Clock module is necessary
IEEE 1588v2 PTP clock (in Future) : Clock module is necessary
Additional PWE E1 channels (per 16E1 up to 63E1)* (in Future) : MSE card is necessary
Main Card Redundancy

For customers name


Page 49 NEC Corporation 2011 NEC Confidential
on 2011/xx/xx

You might also like