Application Standard Measuring Ranges


The moving coil panel meters, DS 48/72/96/144 housed in moulded
D. C. Current D. C. Voltage
polycarbonate cases are suitable for the measurement of DC
currents and voltages. Rated Value Approx Voltage drop Rated Value Sensitivity
(+- 10%)
These instruments offer several advantages in switchboards and *4 *4 *5
Generating Set Panels. Number of meters can be mounted in a 15uA 140 mV 15 mV 3.33kohm/V
*4 *4 *5
25uA 240 mV 25 mV 3.33kohm/V
Panel Cut out (Mosaic mounting). Front glass, Bezel & Dial can be 374 mV *4 *5
3.33kohm/V
40 uA*4 40 mV
easily replaced. 50 uA*4 424 mV 50 mV
*5
3.33kohm/V
60 uA*4 600 mV 60 mV *5 1 kohm/V
Features 100 uA 400 mV 75 mV
*5

*5
1 kohm/V
150 uA 600 mV 100 mV 1 kohm/V
n
Linear scale. 250 uA 140 mV 150 mV
*5
1 kohm/V
*5
n
Glass filled polycarbonate housing (UL 94-V-0) 400 uA 540 mV 250 mV
*5
1 kohm/V
n
Knife edge pointer. 500 uA 540 mV 400 mV 1 kohm/V
*5
600 uA 540 mV 600 mV 1 kohm/V
n
Easily replaceble glass and bezel. 37 mV 1 kohm/V
1 mA 1V
1.5 mA 196 mV 1.5 V 1 kohm/V
Movement 2.5 mA 196 mV 2.5 V 1 kohm/V
4 mA 196 mV 4V 1 kohm/V
Moving coil movement has pivots of very high hardness. 5 mA 196 mV 6V 1 kohm/V
Movement is suspended between two spring loaded sapphire 6 mA 196 mV 10 V 1 kohm/V
jewels. Movement is properly shielded & critically damped by eddy 10 mA 196 mV 15 V 1 kohm/V
15 mA 11 mV 25 V 1 kohm/V
currents induced in coil former. 60 mV 1 kohm/V
20 mA 30 V
25 mA 60 mV 40 V 1 Kohm/V
Mechanical Data 40 mA 60 mV 50 V 1 kohm/V
60 mA 60 mV 60 V 1 kohm/V
Case details Moulded square case suitable 100 mA 60 mV 100 V 1 kohm/V
for mounting in Control / 150 mA 60 mV 150 V 1 kohm/V
Switchgear panels, 250 mA 60 mV 200 V 1 kohm/V
Machinery consoles. 400 mA 60 mV 250 V 1 kohm/V
600 mA 60 mV 300 V 1 kohm/V
Case material Polycarbonate, flame retardant 60 mV 1 kohm/V
1A 400 V
& drip proof as per UL 94 V-0. 1.5 A 60 mV 500 V 1 kohm/V
Front facia Glass 2. 5 A 60 mV 600 V 1 kohm/V
Colour of bazel Black 4A 60 mV 1000 V 1 kohm/V
Position of use Vertical 5A 60 mV For use on
6A 72 mV external
Panel fixing Mounting Clamps 60 mV
10 A shunt
Mounting Stackable in a single cutout 15 A 60 mV 60 mV *5 1 kohm/V
Panel thickness < 25 mm 20 A 60 mV 75 mV
*5
1 kohm/V
25 A 60 mV 150 mV
*5
1 kohm/V
Terminals 30 A 60 mV
Voltmeters and Hexagon studs, M4 screws and 40 A 60 mV
ammeters <5A wire clamps E3 60 A 72 mV
Ammeters >5A Threaded studs M6 with nuts 100 A*6 60 mV
For use on
Ammeters >60A Threaded studs M8 with nuts transducer
4-20 mA 60 mV
Electrical Data Non-Standard ranges available on request.
Measured quantity DC voltage or current

Ziegler Instruments Order No. DS_90_Deg Data sheet-E1.R1-920805-43-2013-EN


Overload capacity (acc. to IS: 1248 / IEC 51) Accuracy at Reference Conditions
Continuously 1.2 times rated voltage / current
Accuracy class 1.5 according to IS: 1248
Short duration (IEC 51/ DIN EN 60051)
Voltmeters 2 times for 0.5 sec : 9 overloads
Reference conditions
2 times for 5 sec : 1 overloads
Ammeters DS 48, 72, 96 Ambient temperature 23 0C + 20C
10 times for 0.5 sec : 9 overloads Position of use Nominal position + 1
10 times for 5 sec : 1 overload Input Rated value of measured quantity
Enclosure code IP 52 case cover Other conditions IS : 1248 (IEC 51/ DIN
(IEC 529) IP 00 for terminals without back EN 60051)
IP 20 for terminals with back
Nominal range of use
cover 0

Insulation class Group A according to VDE 0110 Ambient temperature 0...50 C


Rated insulation voltage DS 48 : 660V DS 72/96 : 1KV Position of use Vertical + 50
Proof Voltage DS 48 : 2KV DS72/96 : 3KV External magnetic field At 0.4KA/m
Installation catagory DS 48 300 V CAT III (IEC 1010)
DS 72/96 600V CAT III(IEC 1010)
Scale and Pointer
Insulation resistance > 50 Mohm at 500 V d.c. Pointer Knife - edge pointer
*4 Accuracy class 2.5 Pointer deflection 0...90
0

*5 Total lead resistance of 0.035 ohm or less considered for mV Scale characteristics linear
ranges while calibration. Scale division Coarse - fine
*6 Not applicable for DS 48
Scale length DS 96 DS 48 DS 72 DS144
41 mm 63 mm 97mm 146mm
Burden Scale Interchangeability Interchangeable
Connection Power Consumtion : 6 mA
to shunt Lead resistance : 0.06 W + 10%

1A ... 60 A Voltage drop : 60 mV + 10%


> 1V 1000 W/V + 5%
www.ziegler-instruments.com 2 | 4

Version: 1/01/I/IX/0410
DS 48 | 72 | 96 | 144
Analogue Meters With Moving Coil Movement - DS

Environmental Conditions Options


Climatic suitability Climate category II as per IS : Case
1248 Front facia Antiglare glass
(climatic class 3 according to Colour of bezel Red, Yellow, Blue, White.
VDE/VDI 3540) Red index pointer Front adjustable on site
Operating temperature - 10... + 550C Position of use 0
on request 0....180 0
0
Storage temperature - 25... + 65 C
Relative humidity <75% annual average, non Dial
condensing Blank dial With initial and end values
Shock resistance 15gnfor pulse duration 11 ms marked.
Vibration resista nce 10-55-10Hz for ampli. 0.15mm Special markings Numbering / Lettering.
(1.5 g at 50Hz) Division dials Basic divisions without
Pollution degree 2 numbering.
Colour markings/bands Red or green
Applicable Standards Others
Nominal case and cutout dimensions for IS 2419 Zero position Centre zero or off-set zero
indicating Electrical instruments DIN IEC 61554 Increased sensitivity 4kohm/V for voltmeters 1...600V
Scale and pointer for electrical IS 1248 10 kohm/V for Voltmeters
measuring 15..150V
instruments DIN 43802 Adjustment of Resistance Within + 1% at 23 C
0

Connections and Terminal markings for IS 1248 (Sensitivity)


panel meters DIN 43807
Terminal bolts / leads. DIN 46200/46282 Accessories
Clamp straps for connections DIN 46282
Safety requirements and protective IS 9249 Safety Terminal protection
measures for Electrical indicating. DIN 40050 Full sized polycarbonate back cover to provide protection against
instruments and their accessories. , VDE 0110 accidental contact (hand and fingers)
VDE 0410
IEC 529 , IEC 1010 Connections
Performance specifications for direct IS 1248
acting indicating analogue electrical IEC 51/DIN EN 60051
measuring instruments & their DIN 43701 11 12

accessories
Environmental condition : IS 1248 +
IS: 9000 DC voltage -
X

VDE / VDI 3540


Front frames for indicating measuring DIN 43718
instruments Principle dimensions
UL Combustibility Class UL 94 V-0 11 12

Technical conditions of delivery for DIN 43701


electrical instruments +
Mechanical strength (Free fall test, IS 1248 DC current X
vibration test) IS 9000 -
VDE 0411

Ziegler Instruments Order No. DS_90_Deg Data sheet-E1.R1-920805-43-2013-EN


IEC 61010
Comply with following European directives: : 2004 / 108 / EC
(EMC directive ), 2006 / 95 /EC (low voltage directive) &
amendment 93/68/EEC, For Marking.

Dimensions f
a 1 x a2
I1 x I 2

h t

Front in mm Nominal Dimensions, mm Cutout, mm Installation Depth Including Terminal (t), mm Installation Depth Incl. Full back Cover (f), mm
a1 x a 2 h I1 x I2 < 4A (M4) 5...60A (M6) 60..100A(M8) < 4A 5...60A 60...100A
+0.6 +0.6
48 x 48 48 x 48 5.5 45 x 45 54 72 62.5 75
+0.7 +0.7
72 x 72 72 x 72 5.5 68 x 68 54 67 67 62.5 70 70
+0.8 +0.8
96 x 96 96 x 96 5.5 92 x 92 54 67 67 62.5 70 70
+1 +1
144 x 144 144 x 144 5.5 138 x 138 54 67 67 62.5 70 70

www.ziegler-instruments.com 3 | 4

Version: 1/01/I/IX/0410
DS 48 | 72 | 96 | 144
Analogue Meters With Moving Coil Movement - DS

Ordering Information
Type
DS Moving-coil panel meter
Front Dimension
48 48mm x 48mm
72 72mm x 72mm
96 96mm x 96mm
144 144mm x 144mm
Measuring Ranges Refer to table inside
*1
Front facia Normal glass
Antiglare glass*3
*1
Colour of Bezel Black
Red, Blue, Yellow, White*3
*1
Position of use Vertical
on request 0....180 0*3
Terminal Protection Full sized polycarbonate back cover
*1 *3 *1
Zero position Left, Off-set zero Centre
*3
Increased sensitivity 4 kohm/V for voltmeters 1...600 V
*3
10 kohm /V for voltmeters 15 ...150 V
Adjustment
*3
Resistance Within + 1 % at 23 C
(Sensitivity)
*1
Dial Standard scale same as measuring range
*3
Blank dial with division
Additional lettering on request*3
*3
Additional numbering on request
*3
Coloured marking red or green
*3
Coloured sector red or green
*1
Logo ZIEGLER

*1
Standard
*3
Please clearly add the desired specifications while ordering

Safety Precautions
1) Instruments with damaged bezel or glasses must be
disconnected from the mains.
2) Adequate safety clearance must be maintained to control panel
fasteners and to sheet metal housing. If non - insulated
connector wires are used.
3) The back cover must be snapped into place after connector

Ziegler Instruments Order No. DS_90_Deg Data sheet-E1.R1-920805-43-2013-EN


wires have been clamped for protection against accidental
contact.
4) Bezel, Scale and Glass may only be replaced under voltage free
conditions.
5) Instruments to be used in grounded panel.

Ordering example
0
DS 72 measuring range 0 ... 20 mA, dial with 0...100 C, red mark at
0
37 C.
Specifications are subject to change without notice (04/10)

ZIEGLER INSTRUMENTS
Schnepfenreuther Weg 6, D-90425 Nrnberg, Germany.
TEL. (+49)(911) 38 492 45 E-MAIL info@ziegler-instruments.com made
International
in :- exp.marketing@rishabh.co.in
FA X . (+49)(911) 32 26 212 WEBSITE www.ziegler-instruments.com
www.rishabh.co.in Germany
www.ziegler-instruments.com 4 | 4

Version: 1/01/I/IX/0410

You might also like