GDS-1000A Series
USER MANUAL
GW INSTEK PART NO. 82DS-1102AMB1
3 4
TABLE OF CONTENTS GDS-1000A Series User Manual
Adjusting the display contrast ............................................. 68 Saving the display image ................................................... 105
Selecting the display grid ..................................................... 68 Saving all (panel settings, display image, waveform) ....... 107
Horizontal View ................................................................. 69 Recall .............................................................................. 109
Moving the waveform position horizontally ........................ 69 File type/source/destination.............................................. 109
Selecting the horizontal scale .............................................. 69 Recalling the default panel settings ................................... 110
Selecting the waveform update mode ................................. 70 Recalling a reference waveform to the display .................. 111
Zooming the waveform horizontally .................................... 71 Recalling panel settings ..................................................... 111
Viewing waveforms in the X-Y mode ................................... 72 Recalling a waveform ......................................................... 112
Horizontal Adjustment Menu .............................................. 73 Recall Image ....................................................................... 114
Vertical View (Channel) ..................................................... 75
Moving the waveform position vertically ............................. 75 PRINT .......................................................... 116
Selecting the vertical scale ................................................... 75
Selecting the coupling mode ............................................... 75 Print (Hardcopy) ............................................................. 116
Expand Vertical Scale Center / Ground ............................... 76
Inverting the waveform vertically ......................................... 77 MAINTENANCE ........................................... 118
Limiting the waveform bandwidth ....................................... 78
Probe attenuation level and type ......................................... 78 Vertical Resolution Calibration ........................................ 118
Trigger ............................................................................... 80 Probe Compensation ....................................................... 119
Trigger type ........................................................................... 80
Trigger parameter ................................................................. 80 FAQ .............................................................. 121
Configuring Holdoff ............................................................. 82 The input signal does not appear in the display. .............. 121
Configuring the edge trigger ................................................ 83 I want to remove some contents from the display. .......... 121
Configuring the video trigger ............................................... 84 The waveform does not update (frozen). .......................... 122
Configuring the pulse width trigger ..................................... 85 The probe waveform is distorted. ...................................... 122
Manually triggering the signal ............................................. 87 Autoset does not catch the signal well. ............................. 122
USB Port Interface ............................................................. 88 I want to clean up the cluttered panel settings. ................ 122
Remote Control Interface .................................................. 89 The saved display image is too dark on the background. . 122
The accuracy does not match the specifications. ............. 123
System Settings ................................................................. 91 The SD card slot does not accept my card. ....................... 123
Viewing the system information .......................................... 91 The oscilloscope will not allow a 2M waveform to be saved.
Selecting the language ......................................................... 91 ............................................................................................ 123
Safety Guidelines
CAUTION
Make sure the BNC input voltage does not
exceed 300V peak.
Never connect a hazardous live voltage to the
ground side of the BNC connectors. It might
This chapter contains important safety instructions
lead to fire and electric shock.
that should be followed when operating and
storing the oscilloscope. Read the following before Do not place heavy objects on the oscilloscope.
any operation to ensure your safety and to keep Avoid severe impact or rough handling that
the oscilloscope in the best condition. may damage the oscilloscope.
Avoid discharges of static electricity on or near
Safety Symbols the oscilloscope.
Use only mating connectors, not bare wires, for
These safety symbols may appear in this manual or on the
the terminals.
oscilloscope.
Do not block the cooling fan vent.
Warning: Identifies conditions or practices that Do not perform measurements at power sources
WARNING could result in injury or loss of life. and building installation sites (Note below).
The oscilloscope should only be disassembled
Caution: Identifies conditions or practices that by a qualified technician.
CAUTION could result in damage to the oscilloscope or to (Measurement categories) EN 61010-1:2001 specifies the
other objects or property. measurement categories and their requirements as follows. The
GDS-1000A falls under category II.
7 8
SAFETY INSTRUCTIONS GDS-1000A Series User Manual
9 10
GETTING STARTED GDS-1000A Series User Manual
GETTING STARTED
recalling data
Calibration output
External trigger input
USB slave interface for remote control
The Getting started chapter introduces the
PictBridge Printer compatible
oscilloscopes main features*, appearance, and set
up procedure. * firmware V1.5.
Main Features
Model name Frequency bandwidth Input channels
GDS-1062A DC 60MHz (3dB) 2
GDS-1102A DC 100MHz (3dB) 2
GDS-1152A DC 150MHz (3dB) 2
Performance 1 GS/s real-time sampling rate
25GS/s equivalent-time sampling rate
2M points record length
Up to 10ns peak detection
2mV~10V vertical scale
1ns ~ 50s time scale
Features 5.6 inch color TFT display
Saving and recalling setups and waveforms
27 automatic measurements
Multi-language menu (12 languages)
Math operation: Addition, Subtraction,
multiplication, FFT, FFT RMS
Edge, video, pulse width trigger
Compact size: (W) 310 x (D) 140 x (H) 142 mm
Probe factor from 0.1X~2000X voltage/current
11 12
GETTING STARTED GDS-1000A Series User Manual
(page62).
Display
Display key Configures the display settings Trigger menu key MENU
Configures the trigger settings
(page67). (page80).
Cursor
Cursor key Runs cursor measurements Single trigger key SINGLE
Selects the single triggering mode
(page55). (page87).
(Continued on next page)
13 14
GETTING STARTED GDS-1000A Series User Manual
CH1
Input terminal Accepts input signals: 1M2%
input impedance, BNC terminal.
15 16
GETTING STARTED GDS-1000A Series User Manual
Menu
17 18
GETTING STARTED GDS-1000A Series User Manual
X1
slightly.
X10
2. Turn to one of the three
preset positions. 8. Press the Autoset key. A
square waveform will
appear in the center of the
display. For details on
Autoset, see page43.
19 20
GETTING STARTED GDS-1000A Series User Manual
Over
Compensation
Normal
Under
Compensation
QUICK REFERENCE
This chapter lists the oscilloscope menu tree,
operation shortcuts, built-in help coverage, and
default factory settings. Use this chapter as a
handy reference to access the oscilloscope
functionalities.
11. Setting up the oscilloscope is complete. You
may continue with the other operations. Menu Tree and Shortcuts
Measurement: page42 Configuration: page62
Conventions Examples
Normal = Press the functional key for Normal
Average = Repeatedly press the functional key for
Average
Normal ~ Average = Select a menu from Normal to Average and
press its functionality key
NormalVAR = Press the functionality key for Normal, and
then use the Variable knob
21 22
QUICK REFERENCE GDS-1000A Series User Manual
Average Cursor
Turn Delay on/off Move X1 cursor
Delay On X1 VAR
Move X2 cursor
X2 VAR
Move both X1 and X2 cursor
X1X2 VAR
CH1/2 key Switch to Y cursor
XY
Turn channel on/off
CH 1/2
Cursor key 2/2
Select coupling mode
Turn cursor on/off
Coupling
Invert waveform Cursor
Move Y1 cursor
Invert
Turn bandwidth limit on/off Y1 VAR
Move Y2 cursor
BW Limit
Select probe type Y2 VAR
Expand type XY
Expand
23 24
QUICK REFERENCE GDS-1000A Series User Manual
25 26
QUICK REFERENCE GDS-1000A Series User Manual
Math on/off
Math
Select math operation type (+/
/x/FFT/FFT rms)
Operation
Set result position
PositionVAR
Math result Volt/Div
Unit/DivVOLTS/DIV(CH2)
27 28
QUICK REFERENCE GDS-1000A Series User Manual
Recall
Go to SD card file utilities
File Utilities
29 30
QUICK REFERENCE GDS-1000A Series User Manual
Save Save
31 32
QUICK REFERENCE GDS-1000A Series User Manual
Select other menu Trigger Type Trigger Holdoff Select Trigger type or Trigger
MENU MENU
Holdoff menu
Save All
Turn on/off ink saver Type
Type Holdoff
Edge 40.0ns
Ink Saver
Source Set to
Select destination CH1 Minimum
Destination VAR
Slope /
Save all
Coupling
Save Mode
Auto
Go to SD card file utilities
File Utilities
Trigger key 2/6
33 34
QUICK REFERENCE GDS-1000A Series User Manual
35 36
QUICK REFERENCE GDS-1000A Series User Manual
37 38
QUICK REFERENCE GDS-1000A Series User Manual
Probe compensation Select probe compensation signal Display Type: Vectors Accumulate: Off
Wave Type
/ Wave Type Grid:
Frequency ( only) Set frequency for square wave Horizontal Scale: 2.5us/Div Mode: Main Timebase
1K 1k ~ 100k
Duty Cycle ( only) FrequencyVAR H Pos Adj: Fine Hor Pos:0
50% 5% ~ 95%
Set duty cycle for square wave Math Type: + (Add) Position: 0.00 Div
Default
1kHz Duty CycleVAR Measure Item: Vpp, Vavg, Frequency, Duty Cycle, Rise
Previous Time
Menu
Go to previous menu
Previous Menu Trigger Type: Edge Source: Channel1
Mode: Auto Slope:
Coupling: DC Rejection: Off
Noise Rejection: Off
Utility Hardcopy: SaveImage, ProbeComp: Square
InkSaver Off wave, 1k, 50% duty cycle
39 40
QUICK REFERENCE GDS-1000A Series User Manual
Built-in Help
MEASUREMENT
Help
The Help key shows the contents of the built-in
help support. When you press a function key, its
descriptions appear in the display.
Acquire Display Utility Help Autoset
Applicable keys
The Measurement chapter describes how to
Cursor Measure Save/Recall Hardcopy Run/Stop properly observe a signal using the oscilloscopes
basic functions, and how to observe a signal in a
detailed manner using some of the advanced
(Vertical) (Horizontal) (Trigger) functions such as :
CH 1 MATH CH 2 MENU MENU
Automatic measurements, cursor measurements,
SINGLE
and math operations.
VARIABLE
Activating a To activate an input channel, CH 1 CH 2
3. Use the Variable knob to channel press the Channel key, CH1 or
scroll the Help contents up CH2. The channel indicator or
and down. appears at the left side of the
Help
display and the channel icon
4. Press the Help key again to changes accordingly.
exit the Help mode.
(Continued on next page)
41 42
MEASUREMENT GDS-1000A Series User Manual
Undo option
Background The Autoset function automatically configures the Limitation Autoset does not work in the following situation.
panel settings to the best viewing conditions, in the Input signal frequency less than 20Hz
following way. Input signal amplitude less than 30mV
Selecting the horizontal scale
Positioning the waveform horizontally
Running and stopping the trigger
Selecting the vertical scale
Positioning the waveform vertically Background In the trigger Run mode, the oscilloscope
constantly searches for a trigger condition and
Selecting the trigger source channel
updates the signal into the display when the
Activating the channels condition is met.
Autoset In the trigger Stop mode, the oscilloscope stops
Procedure 1. Connect the input signal to
triggering and thus the last acquired waveforms
the oscilloscope and press
stay in the display. The trigger icon at the top of
the Autoset key.
the display changes into Stop mode.
43 44
MEASUREMENT GDS-1000A Series User Manual
TIME/DIV
Selecting the To select the timebase (scale), turn
horizontal scale the TIME/DIV knob; left (slow) or
right (fast).
Changing the horizontal position and scale Changing the vertical position and scale
For more detailed configurations, see page69. For more detailed configuration, see page75.
Setting the The horizontal position knob Set vertical To move the waveform up or
horizontal moves the waveform left or right. position down, turn the vertical position
position
The position indicator moves along with the knob for each channel.
waveform and the distance from the center point is As the waveform moves, the vertical position of
displayed as the offset in the upper side of the the cursor appears at the bottom left corner of the
display. display.
Run/Stop mode The waveform can be moved
vertically in both Run and Stop
mode.
VOLTS/DIV
Select vertical To change the vertical scale,
scale turn the VOLTS/DIV knob; left
(down) or right (up).
45 46
MEASUREMENT GDS-1000A Series User Manual
3. Press ProbeComp.
Using the probe compensation signal
View the probe 1. Connect the probe between the compensation Range 5% ~ 95%
compensation signal output and Channel input. Probe For probe compensation details, see page119.
waveform compensation
GDS-1152A
CH1
x1
x10
Utility
2. Press the Utility key.
47 48
MEASUREMENT GDS-1000A Series User Manual
Overview Voltage type Time type Delay type RPREShoot Rise preshoot voltage.
49 50
MEASUREMENT GDS-1000A Series User Manual
Measure
2. Press the Measure key.
51 52
MEASUREMENT GDS-1000A Series User Manual
7. Press F2 repeatedly to
change the channel for
Source2.
Range CH1, 2, Math
53 54
MEASUREMENT GDS-1000A Series User Manual
55 56
MEASUREMENT GDS-1000A Series User Manual
57 58
MEASUREMENT GDS-1000A Series User Manual
59 60
MEASUREMENT GDS-1000A Series User Manual
MATH
8. To clear the FFT result from
the display, press the Math
CONFIGURATION
key again.
Acquisition
The acquisition process samples the analog input signals and
converts them into digital format for internal processing. You may
select the normal, average, or peak detect acquisition mode.
Acquire
Procedure 1. Press the Acquire key.
Peak
Detect
61 62
CONFIGURATION GDS-1000A Series User Manual
Acquire
6. Press the Acquire key.
63 64
CONFIGURATION GDS-1000A Series User Manual
Acquire
Procedure 1. Press the Acquire key.
TIME/DIV
4. Adjust the horizontal scale
to zoom into the waveform.
65 66
CONFIGURATION GDS-1000A Series User Manual
Procedure 1. Press the Display key. Display Adjusting the display contrast
Display
67 68
CONFIGURATION GDS-1000A Series User Manual
Moving the waveform position horizontally Main mode Updates the whole displayed waveform at once.
The main mode is automatically selected when the
Procedure The horizontal position knob horizontal scale (timebase) is fast.
moves the waveform left or Horizontal scale 100ms/div
right. The position indicator at Trigger All modes available
the top of the display shows the
center and current position. Roll mode Updates and moves the waveform gradually from
the right side of the display to the left. The Roll
Center position Moving right
mode is automatically selected when the
horizontal scale (timebase) is 250ms or slower.
When in the Roll mode, an indicator appears at the
bottom of the display. When in roll mode the
record length is 2M (1 channel) or 1M (2 channel).
Selecting the horizontal scale
Main mode Roll mode
TIME/DIV
Select horizontal To select the timebase (scale),
scale turn the TIME/DIV knob; left
(slow) or right (fast). Timebase 250ms/div (250KS/s)
Trigger Auto mode only
Range 1ns/Div ~ 50s/Div, 1-2.5-5-10 increment
The timebase indicator at the bottom of the display Selecting the Roll 1. Press the Horizontal menu MENU
69 70
CONFIGURATION GDS-1000A Series User Manual
MENU
Background The X-Y mode compares the voltage of Channel 1
Procedure/ range 1. Press the Horizontal Menu and Channel 2 waveforms in a single display. This
key. mode is useful for observing the phase relationship
between the two waveforms.
2. Press Window.
Procedure 1. Connect the signals to
Channel 1 (X-axis) and
3. Use the horizontal position Channel 2 (Y-axis).
knob to move the zoom
CH 1 CH 2
range sideways, and TIME/DIV 2. Make sure both Channel 1
TIME/DIV knob to change and 2 are activated.
the zoom range width.
MENU
3. Press the Horizontal key.
The width of the bar in the middle of the
display is the actual zoomed area.
4. Press XY. The display
Zoom range 1ns ~ 25s shows two waveforms in X-
Y format; Channel 1 as X-
4. Press Window Zoom. The axis, Channel 2 as Y-axis.
specified range gets
zoomed. Adjusting the X-Y Horizontal position CH1 Position knob
mode waveform
Example Horizontal scale CH1 Volts/Div knob
Vertical position CH2 Position knob
Vertical scale CH2 Volts/Div knob
Example
71 72
CONFIGURATION GDS-1000A Series User Manual
MENU MENU
1. Press the Horizontal menu
key twice to enter the
horizontal adjustment menu
73 74
CONFIGURATION GDS-1000A Series User Manual
CH 1
Procedure 1. Press the Channel key.
75 76
CONFIGURATION GDS-1000A Series User Manual
CH 1
Procedure 1. Press the Channel key.
Limiting the waveform bandwidth
2. Press F5 to toggle between Background Bandwidth limitation puts the input signal into a
Expand Center and Expand 20MHz (3dB) low-pass filter. This function is
Ground. useful for cutting off high frequency noise to see
the clear waveform shape.
VOLTS/DIV
3. To change the vertical scale,
CH 1
turn the VOLTS/DIV knob; Procedure 1. Press the Channel key.
left (down) or right (up).
CH 1
Procedure 1. Press the Channel key.
CH 1
Procedure 1. Press the Channel key.
77 78
CONFIGURATION GDS-1000A Series User Manual
4. The voltage/current scale in the channel Edge Triggers when the signal crosses an amplitude
indicator changes accordingly. There is no threshold in either a positive or negative slope.
change in the waveform shape. Video Extracts a sync pulse from a video format signal
Range x0.1~x2000 (1-2-5 steps) and triggers on a specific line or field.
Note: The attenuation factor adds no influence on Pulse Triggers when the pulse width of the signal
the real signal; it only changes the voltage/current matches the trigger settings.
scale on the display. Indicators Edge/Pulse Video
Trigger parameter
79 80
CONFIGURATION GDS-1000A Series User Manual
The Auto trigger status appears in the line 1~263 for NTSC, 1~313 for PAL/SECAM
upper right corner of the display.
Pulse condition Sets the pulse width (20ns ~ 10s) and the triggering
(pulse trigger) condition.
> Longer than = Equal to
< Shorter than Not equal to
SINGLE
Single The oscilloscope acquires the
input signals once when a
Trigger slope Triggers on the rising edge.
trigger event occurs, then Triggers on the falling edge.
stops acquiring. Pressing the
Single key again will repeat Trigger coupling AC Triggers only on AC component.
the process.
DC Triggers on AC+DC component.
The Single trigger status appears in the
upper right corner of the display. Frequency LF Puts a high-pass filter and rejects the
rejection frequency below 50kHz.
(Searching) (Triggered)
HF Puts a low-pass filter and rejects the
frequency above 50kHz.
Normal The oscilloscope acquires and updates
Noise rejection Rejects noise signals.
the input signals only when a trigger
LEVE L
event occurs. Trigger level Using the trigger level knob moves the
The Normal trigger status appears in the trigger point up or down.
upper right corner of the display.
(Searching) (Triggered) Configuring Holdoff
81 82
CONFIGURATION GDS-1000A Series User Manual
83 84
CONFIGURATION GDS-1000A Series User Manual
85 86
CONFIGURATION GDS-1000A Series User Manual
87 88
CONFIGURATION GDS-1000A Series User Manual
USB connection PC / Printer end Type A, host 6. Configuring the command interface is
GDS-1000A end Type B, slave complete. Refer to the programming manual for
the remote commands and other details.
Speed 1.1/2.0 (full speed)
89 90
CONFIGURATION GDS-1000A Series User Manual
Utility
System Settings Procedure 1. Press the Utility key.
Utility
Procedure 1. Press the Utility key.
91 92
SAVE/RECALL GDS-1000A Series User Manual
Contents The current display image in 234 x 320 pixels, color Waveform The memory depth is limited to 1 M points when
mode. The background color can be inverted (Ink Memory Depth both channels are activated or 2M points when
saver function). only a single channel is activated. The signal must
be triggered /stopped to have access to the full
memory depth. Therefore when a signal is saved
Waveform file format the waveform will be automatically stopped if it is
not manually triggered /stopped first.
Format xxxx.csv (Comma-separated values format which There are a number of conditions when all of the
can be opened in spreadsheet applications such as available memory is not utilized due to a limited
Microsoft Excel) number of different sample rates. This can be
Files can be saved as two different types of CSV caused by an un-triggered signal, or a time/div
formats. The GDS-1000A can recall any of the two setting that is too fast to display all the points on
formats screen.
93 94
SAVE/RECALL GDS-1000A Series User Manual
95 96
SAVE/RECALL GDS-1000A Series User Manual
Using the SD card file utilities SD card indicator When an SD card is inserted into the oscilloscope,
an indicator appears at the right bottom corner of
Background When an SD card is inserted into the oscilloscope, the display. (The SD card shouldnt be removed
file utilities (file deletion, folder creation and when a file is saved or retrieved from the SD card).
file/folder renaming) are available from the front SD card
panel.
SD Card The GDS-1000A series accepts the following SD
restriction cards:
Type: SD, SDHC Creating a new 1. Move the cursor to the file
Class: 2,4,6 folder / renaming or folder location and press
a file or folder New Folder or Rename. The
Size: Up to 32GB (SDHC)
Format: FAT or FAT32 file/folder name and the
character map will appear
Procedure 1. Insert an SD card into the on the display.
card slot.
VARIABLE
Save/Recall
2. Use the Variable knob to
2. Press the Save/Recall key. move the pointer to the
Select any save or recall characters. Press Enter
function. For example SD (Example) Character to add a character
card destination in the Save or Back Space to delete a
image function. character.
97 98
SAVE/RECALL GDS-1000A Series User Manual
Utility
2. Press the Utility key.
99 100
SAVE/RECALL GDS-1000A Series User Manual
101 102
SAVE/RECALL GDS-1000A Series User Manual
103 104
SAVE/RECALL GDS-1000A Series User Manual
105 106
SAVE/RECALL GDS-1000A Series User Manual
3. Press Save All. The following The file will not be saved if the
Note power is turned off or the SD card is
information will be saved.
disconnected before completion.
Setup file Two types of setups are saved: It takes approximately 1 min to save
(Axxxx.set) the current panel setting and a 2M waveform to the SD card in
the last internally saved fast mode. Detailed mode may take
settings (one of S1 ~ S15). over 10 times longer depending on
Display image The current display image in the speed of the SD card.
(Axxxx.bmp) the bitmap format.
7. Together with the current setup/waveform/
Waveform data Two types of waveform data image, the last saved waveform file (one from
(Axxxx.csv) are saved: the currently active W1 ~ W15) and setup file (one from S1 ~ S15)
channel data and the last are also included in the folder.
internally saved data (one of
W1 ~ W15).
File utilities To edit SD card contents
(create/ delete/ rename files
4. Press Ink Saver repeatedly to and folders), press File Utilities.
invert the background color For details, see page97.
(on) or not (off) for the
display image.
5. Press Destination.
107 108
SAVE/RECALL GDS-1000A Series User Manual
109 110
SAVE/RECALL GDS-1000A Series User Manual
Save/Recall
2. Press the Save/Recall key.
111 112
SAVE/RECALL GDS-1000A Series User Manual
3. Press Recall Waveform. The File utilities To edit the SD card contents
display shows the available (create/ delete/ rename files
source and destination and folders), press File Utilities.
options. For details, see page97.
113 114
SAVE/RECALL GDS-1000A Series User Manual
VARIABLE
4. Use the Variable knob to
choose a file name
PRINT
(DSXXXX.BMP).
SD card The image file must be placed
in the root directory to be
recognized.
The GDS-1000A is able to print screen images
5. Press Recall to confirm directly to a PictBridge compatible printer. The
recalling. When completed, printed images can use the Ink Saver feature to
a message appears at the print onto a white rather than a black background
bottom of the display. to reduce the amount of ink used. Note that
printing and remote control cannot be used at the
6. Press Reference Image to turn same time.
on /off the current image.
115 116
PRINT GDS-1000A Series User Manual
Hardcopy
7. Press the Hardcopy key.
The current screen image 2. Press More.
will be printed to the
printer.
117 118
MAINTENANCE GDS-1000A Series User Manual
Autoset
5. Press the Autoset key. The
8. When finished, connect the Done!! compensation signal will
calibration signal to the
appear in the display.
Channel 2 input and repeat
the procedure.
6. Press the Display key, then
Type to select the vector
9. When the calibration is complete the display
waveform.
will go back to the previous state.
Probe Compensation
Procedure 1. Connect the probe between the Channel1 input 7. Turn the adjustment point on the probe until
and the probe compensation output (2Vp-p, the signal edge becomes sharp.
1kHz square wave) on the front panel. Set the
probe voltage attenuation to x10.
Over Under
Normal
CH1
Compensation Compensation
Utility
2. Press the Utility key.
3. Press ProbeComp.
119 120
FAQ GDS-1000A Series User Manual
FAQ Press the Run/Stop key to unfreeze the waveform. See page44 for
details. For trigger setting details, see page80.
If this does not help, press the CH key. If the signal still does not
appear, press the Autoset key.
The input signal does not appear in the display.
I want to remove some contents from the display. The probe waveform is distorted.
The waveform does not update (frozen).
The probe waveform is distorted. You might need to compensate the probe. For details, see page119.
Note that the frequency accuracy and duty factor are not specified
Autoset does not catch the signal well. for probe compensation waveforms and therefore it should not be
I want to clean up the cluttered panel settings. used for other reference purposes.
The accuracy does not match the specifications.
The SD card slot does not accept my card. Autoset does not catch the signal well.
The oscilloscope will not allow a 2M waveform to be saved.
The Autoset function does not catch signals well under 30mV or
20Hz. Please operate the oscilloscope manually. See page43 for
details.
The input signal does not appear in the display.
Make sure you have activated the channel by pressing the CH key I want to clean up the cluttered panel settings.
(page42).
Recall the default settings by pressing the Save/Recall keyDefault
Setting. For default setting contents, see page40.
I want to remove some contents from the display.
To clear the math result, press the Math key again (page58). The saved display image is too dark on the background.
To clear the cursor, press the Cursor key again (page55).
Use the Inksaver function which reverses the background color. For
To clear the Help contents, press the Help key again (page41). details, see page105.
121 122
FAQ GDS-1000A Series User Manual
Make sure that only 1 channel is active. Make sure that the signal
has been triggered and that the STOP or Single key has been pressed.
Ensure the time base is slower than 10 ns/div. See page 93.
123 124
APPENDIX GDS-1000A Series User Manual
125 126
APPENDIX GDS-1000A Series User Manual
Cursors and Voltage Vpp, Vamp, Vavg, Vrms, Vhi, Vlo, Vmax, Probe Specifications
Measurement Vmin, Rise Preshoot/ Overshoot, Fall
Preshoot/ Overshoot
Time Freq, Period, Rise Time, Fall Time, + GDS-1062A/1102A/1152A Probe
Width, Width, Duty Cycle
Delay FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF Applicable model & GDS-1062A GDS-1102A
Cursors Voltage difference (V) and probe GTP-060A-4* GTP-100A-4*
Time difference (T) between cursors Position x 10 Attenuation Ratio 10:1
Auto Counter Resolution: 6 digits, Accuracy: 2% Bandwidth DC ~ 60MHz DC ~ 100MHz
Signal source: All available trigger source Input Resistance 10M when used with 1M input
except the Video trigger Input Capacitance 23pF approx. 17pF approx.
Control Panel Autoset Automatically adjust Vertical Volt/div, Maximum Input 500V CAT I, 300V CAT II (DC+Peak AC)
Function Horizontal Time/div, and Trigger level Voltage Derating with frequency
Save/Recall Up to 15 sets of measurement Position x 1 Attenuation Ratio 1:1
conditions and waveforms Bandwidth DC ~ 6MHz
Display LCD 5.6 inch, TFT, brightness adjustable Input Resistance 1M when used with 1M input
Resolution (dots) 234 (Vertical) x 320 (Horizontal) Input Capacitance 128pF approx. 47pF approx.
Graticule 8 x 10 divisions Maximum Input 300V CAT I, 150V CAT II (DC+Peak AC)
Display Contrast Adjustable Voltage Derating with frequency
Interface USB Slave USB1.1 & 2.0 full speed compatible Operating Cond. Temperature 10C ~ 55C
Connector (flash disk not supported) Relative Humidity 85% @35C
SD Card Slot Image (BMP) and waveform data (CSV) Safety Standard EN 61010-031 CAT II
Probe Frequency range 1kHz ~ 100kHz adjustable, 1kHz step
Compensation
Signal Applicable model & GDS-1152A GTP-150A-2*
Duty cycle 5% ~ 95% adjustable, 5% step probe
Amplitude 2Vpp3% Position x 10 Attenuation Ratio 10:1
Power Source Line Voltage 100V~240V AC, 47Hz~63Hz Bandwidth DC ~ 150MHz
Power 18W, 40VA maximum Input Resistance 10M when used with 1M input
Consumption Input Capacitance 17pF approx.
Fuse Rating 1A slow, 250V Maximum Input 500V CAT I, 300V CAT II (DC+Peak AC)
Operation Ambient temperature 0 ~ 50C Voltage Derating with frequency
Environment Relative humidity 80% @35C Position x 1 Attenuation Ratio 1:1
Storage Ambient temperature 10C to 60C Bandwidth DC ~ 6MHz
Environment Relative humidity 80% @60C Input Resistance 1M when used with 1M input
Dimensions 310(W) x 142(H) x 140(D) mm Input Capacitance 47pF approx.
Weight Approx. 2.5kg Maximum Input 300V CAT I, 150V CAT II (DC+Peak AC)
Voltage Derating with frequency
Operating Cond. Temperature 10C ~ 55C
Relative Humidity 85% @35C
Safety Standard EN 61010-031 CAT II
* Note: GW Instek reserves the right to change the probe model type (GTP-060A-4,
GTP-100A-4, GTP-150A-2) at anytime without notice for probe model types of similar
specification.
127 128
APPENDIX GDS-1000A Series User Manual
EC Declaration of Conformity
INDEX
We
GOOD WILL INSTRUMENT CO., LTD.
No.7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan
GOOD WILL INSTRUMENT (SUZHOU) CO., LTD.
No. 69, Lushan Road, Suzhou New District Jiangsu, China
2M memory length limits ......... 94 Cursor.......................................... 55
declares that the below mentioned product AC coupling ............................... 76 faq.................................................. 121
Accumulating waveform.......... 67 menu tree ....................................... 24
GDS-1062A, GDS-1102A, GDS-1152A Acquisition ................................. 62 shortcut .......................................... 24
menu tree ....................................... 23 specification................................. 127
Are herewith confirmed to comply with the requirements set out in the Cycle time measure ................... 50
short cut ......................................... 23
Council Directive on the Approximation of the Law of Member States DC coupling ............................... 75
specification................................. 126
relating to Electromagnetic Compatibility (2004/108/EC) and Low Addition...................................... 59 Declaration of conformity....... 129
Voltage Equipment Directive (2006/95/EC). For the evaluation Amplitude measure .................. 49 Default setup ............................ 110
regarding the Electromagnetic Compatibility and Low Voltage Auto set....................................... 43 contents .......................................... 40
Equipment Directive, the following standards were applied: exception ........................................ 44 menu tree ....................................... 29
specification................................. 127 Delay measure............................ 50
EMC Auto trigger................................ 80 Delay mode................................. 64
Automatic measurement .......... 52 Delay Off..................................... 65
EN 61326-1 : Electrical equipment for measurement, control and
menu tree ....................................... 28 Delay On ..................................... 64
EN 61326-2-1: laboratory use EMC requirements (2006)
overview ........................................ 49 Display ........................................ 68
Conducted and Radiated Emissions Electrostatic Discharge
shortcut .......................................... 28 contrast setting.............................. 68
CISPR11: 2003+A1: 2004+A2: 2006 IEC 61000-4-2: 2001
specification................................. 127 diagram .......................................... 18
Current Harmonic Radiated Immunity
EN 61000-3-2: 2006 IEC 61000-4-3: 2006+A1: 2007 Automatic measurement gating grid setting..................................... 68
Voltage Fluctuation Electrical Fast Transients ................................................. 51 menu tree ....................................... 25
EN 61000-3-3: 1995+A1: 2001+A2 : 2005 IEC 61000-4-4: 2004+Corr.1 : 2006+Corr.2 : Average acquisition .................. 63 shortcut .......................................... 25
2007 Average voltage measure ......... 50 specification................................. 127
Surge Immunity Bandwidth limitation................ 78 Display image
-------------------------
IEC 61000-4-5: 2005 faq.................................................. 122
Blackman window..................... 59
Conducted Susceptibility file format ...................................... 93
-------------------------
IEC 61000-4-6: 2003+A1: 2004+A2: 2006 Calibration recall menu tree ............................ 30
menu tree ....................................... 37 save ............................................... 105
Power Frequency Magnetic Field
------------------------- Calibration, vertical resolution
IEC 61000-4-8: 2001 save menu tree .............................. 32
Voltage Dips/ Interrupts ............................................... 118 Dot waveform ............................ 67
-------------------------
IEC 61000-4-11: 2004 Caution symbol............................ 7 Duty cycle measure ................... 50
Channel....................................... 42 Edge trigger ................................ 83
Safety faq.................................................. 121 menu tree ....................................... 35
menu tree ....................................... 23 EN 61010-031............................ 128
Low Voltage Equipment Directive 2006/95/EC shortcut .......................................... 23
Safety Requirements EN61010
Cleaning the instrument ............. 9 measurement category .................. 8
IEC/EN 61010-1: 2001
Configure remote control ......... 90 pollution degree.............................. 9
Coupling mode .......................... 75 Environment............................. 127
menu tree ....................................... 23 safety instructions .......................... 9
129 130
INDEX GDS-1000A Series User Manual
Equivalent time sampling ......... 66 Horizontal menu compensation signal overview ... 47 Setting up the oscilloscope ....... 19
Expand Center............................ 76 shortcut .......................................... 26 faq.................................................. 122 Setup
Expand Ground ......................... 76 Image peak detect demonstration.......... 63 default contents ............................ 40
External trigger .......................... 80 recall ............................................. 114 Pulse time measure ................... 50 file format ...................................... 96
input terminal ............................... 16 Ink saver Pulse width trigger .................... 85 how to save .................................. 103
Falling time measure ................. 50 in display save ............................ 106 condition ........................................ 82 recall ............................................. 111
in hardcopy.................................. 101 menu tree ....................................... 35 recall menu tree ............................ 29
Faq ............................................. 122
in print .......................................... 117 Real time sampling .................... 66 save menu tree .............................. 31
FFT ............................................... 60
in save all ..................................... 107 Rear panel diagram ................... 17 Single trigger .............................. 87
menu tree ....................................... 27
overview ........................................ 58 Input frequency indicator ......... 18 Recall ......................................... 109 Single trigger mode ................... 81
File format................................... 93 Invert waveform......................... 77 default setup ................................ 110 Specifications ............................ 125
Language selection .................... 91 image ............................................ 114 faq.................................................. 123
Firmware version ....................... 91
List of features ............................ 11 menu tree ....................................... 29 Subtraction.................................. 59
Flattop window .......................... 58 reference waveform ................... 111
Low voltage measure ................ 50 System information ................... 91
Force trigger ............................... 87 setup ............................................. 111
Math Timebase indicator .................... 69
Frequency measure.................... 50 shortcut .......................................... 29
faq.................................................. 121 Trigger ......................................... 80
Frequency rejection ................... 82 waveform ..................................... 112
menu tree ....................................... 27 coupling ......................................... 82
Front panel diagram .................. 13 overview ........................................ 58 Rectangular window ................. 58 edge................................................. 83
Fuse replacement ..................... 124 shortcut .......................................... 27 Reference waveform force ................................................ 87
safety instruction ............................ 9 Measurement .............................. 42 menu tree ....................................... 31 indicator ......................................... 80
Gated Automatic measurements recall.............................................. 111 level knob....................................... 82
Memory Length
................................................. 51 faq.................................................. 123 Remote control interface..... 88, 89 menu tree ....................................... 34
General purpose signal ............. 47 Model caomparison ................... 11 Rising time measure .................. 50 parameter ....................................... 80
Ground Roll mode ................................... 70 pulse width .................................... 85
Multiplication ............................. 59
coupling ......................................... 75 Root mean square measure ...... 50 shortcut .......................................... 34
Negative peak measure ............. 49 specification ................................. 126
symbol .............................................. 7 Run/stop .................................... 44
Noise rejection ............................ 82 status indicator.............................. 18
terminal .......................................... 15 faq.................................................. 122
Normal acquisition .................... 62 video ............................................... 84
Hanning window ....................... 58 Save ........................................... 102
Normal trigger............................ 81 UK power cord........................... 10
Hardcopy .................................. 100 display image .............................. 105
shortcut .......................................... 38 NTSC ........................................... 81 menu tree ....................................... 29 Utility
Hardcopy Printer Operating environment ........... 127 setup ............................................. 103 key overview ................................. 14
menu tree ....................................... 38 Overshoot voltage measure ...... 50 shortcut .......................................... 29 menu tree ....................................... 37
Page size specification ................................. 127 shortcut .......................................... 37
Hardcopy Save All
menu tree ....................................... 38 in print .......................................... 117 waveform ..................................... 104 Vector waveform ....................... 67
Hardcopy Save image PAL .............................................. 81 Save all ...................................... 107 Vertical ........................................ 75
menu tree ....................................... 39 Peak detect acquisition .............. 63 menu tree ....................................... 33 basic operation .............................. 46
Peak to peak measure ................ 49 SD card cursor operation............................ 56
Help ............................................. 41
faq.................................................. 123 position........................................... 75
faq.................................................. 121 Peak voltage measure ................ 49
file menu tree ................................ 33 resolution calibration ................. 118
High voltage measure ............... 49 Power on/off scale................................................. 75
safety instruction ............................ 8 file operation ......... 97, 100, 102, 109
holdoff ......................................... 82 specification ................................. 126
switch overview ............................ 17 SECAM ....................................... 81
Horizontal ................................... 69 Video line .................................... 81
basic operation .............................. 45 Preshoot voltage measure ......... 50 Security lock slot ........................ 17
Serial number ............................. 91 Video trigger .............................. 84
cursor operation............................ 55 Print ........................................... 116 menu tree ....................................... 34
menu tree ....................................... 26 Probe .......................................... 119 Service operation
about disassembly .......................... 8 Warning symbol .......................... 7
position........................................... 69 attenuation level ........................... 78
scale................................................. 69 contact .......................................... 123 Waveform
attenuation menu tree .................. 23
specification ................................. 126 Setting the handle ...................... 19 expand waveform......................... 76
compensation menu tree ............. 39
file format ...................................... 93
131 132
INDEX
133