Rectangular
Oil/Water Separators
UL-SU-2215 Approved
UL Approved HTC Models Aboveground, grade-level or Exterior insulation and immersion heaters
Certified for 10 ppm oil and belowground vaulted installation available for cold climate installations
grease discharge* Rugged all-steel construction for Available with complete equipment
Available in sixteen popular sizes superior structural strength packages including level sensors,
- Custom systems available Removable, vapor-tight top covers alarm/control panels, and pump
Flow rates ranging 5 to 1,200 GPM for access and maintenance systems
Patented internal baffles and Superior product compatibility
coalescers for proven performance *Other non UL Labeled models are also available.
Custom Designed and Fabricated to Your Needs
INLET Lifting
Lugs
Height
OUTLET
Velocity Head
Diffusion Baffle
Optional Optional
Sludge PETRO-SCREEN Effluent
Support
Hopper Coalescer Transfer Pipes
Legs
Model Nominal Capacity Spill Capacity Flow Rate Dimensions Inlet/Outlet Approximate Wt.
R-HTC (Gallons) (Gallons) (gpm) LxWxH Diameter (lbs.)
DSB Deep Sump Catch Basin Influent Pump Packaged System Effluent Pump Packaged System
Pump Discharge
to Separator Removable Lid
with Lifting Handle
Influent
Diaphram
Pump
Supply
Vent
Concrete
Level Sensor Floor
Suction Pipe
INLET
Striker
Plate
Strainer
Integral Grit
Pump Lift Chamber Chamber
DSB Systems are available in two standard flow Oil Pump-Out Packaged System Advanced Secondary Treatment System
rates. The DSB-300 sized for 0-25 GPM and the
DSB-600 sized for 0-50 GPM. Higher flow rate
systems are also available.
Standard Features
DSB- Deep Sump Basin with Inlet
Pneumatic Influent Diaphragm Pump
with Air Filter Regulator, Suction Pipe
and Strainer
R-HTC-300 or R-HTC-600 Oil/Water
Separator with Level Sensor and Controls
New Systems or Retro-Fit Existing Sites
Highland can incorporate an Oil Pump-out system Highlands Advanced Secondary Treatment
with pump, sensors and controls. The pump can Systems are used in applications where strict
be mounted on the tank or mounted remotely. The water quality discharges are mandated. These
self-priming centrifugal pumps are available with convenient, compact, modular systems use a
explosion-proof components. proprietary media to remove impurities from
Pump and control packages are available in a variety of wastewater by physical adsorption.
NEMA ratings and for explosion-proof environments.
Pre-Engineered Design Options
Separator installations vary greatly with each location.
Highland custom fabricates oil/water separators to
satisfy your specific needs. The following information
illustrates some of the design options available.
Series G
INLET Lifting
Series G oil/water separators feature an integral sand Lugs
interceptor compartment to permit sand and gravel to settle out
OUTLET
before the wastewater enters the separation chamber.
Velocity Head
Diffusion Baffle
PETRO-SCREEN Effluent
Coalescer Transfer Pipes
PETRO-SCREEN Effluent
Coalescer Transfer Pipes
PETRO-SCREEN Effluent
Coalescer Transfer Pipes
permits the removal of only the skimmed oil by pump-out. The OUTLET
effluent is discharged either by pump or gravity flow. Oil Skimmer
INLET Lifting
Lugs
Height
OUTLET
Velocity Head
Diffusion Baffle
Optional Optional
Model R-HTC with optional Sludge Hopper for Sludge PETRO-SCREEN Effluent
Support
10 ppm oil/grease discharge (shown) Hopper Coalescer Transfer Pipes
Legs
Influent Characteristics General Description Internal surfaces commercial sand-blast, coated with 10
The separator shall be designed for intermittent and variable Separator shall be a rectangular inclined parallel corrugated mils DFT Polyurethane or as specified.
flows of water, oil or any combination of non-emulsified oil- plate oil water separator with removable top cover(s). The
water mixtures ranging from zero to _____, the units rated separator shall be a pre-packaged, pre-engineered, ready to External surfaces commercial sand-blast, coated with
GPM flow. Operating temperatures of the influent oil in install unit consisting of: Polyurethane or as specified.
water mixture shall range from 40 to 100 F. The specific
gravities of the oils at operating temperatures shall range An influent connection __________ inch. An internal in- For information and specifications on models other than the
from 0.68 to 0.95. The specific gravity of the fresh water at fluent nozzle at the inlet end of the separator, located at the R-HTC, contact Highland Tank or an authorized factory
operating temperatures shall range from 1.00 to 1.03. furthest diagonal point from the effluent discharge opening. representative.
Effluent Characteristics
The free oil and grease concentration in the effluent from the A velocity head diffusion baffle at the inlet end to: Accessories and Options
separator shall not exceed 10 mg/l (10 ppm). To achieve reduce horizontal velocity and flow turbulence Oil level controls to activate audible and visual alarms at
this goal, it will be necessary to remove all free oil droplets distribute the flow equally over the separator's cross predetermined oil levels. All components are intrinsically
equal to and greater than 20 microns. sectional area safe and enclosed in NEMA IV enclosures.
direct the flow in a serpentine path to enhance hydraulic
Design Criteria characteristics and fully utilize all separator volume Oil level/liquid level controls to start and stop an explosion
Construction and performance cerfication of the separator completely isolate all inlet turbulence from the separation proof oil pump and to activate audible and visual alarms at
shall be in strict accordance with Underwriters Laboratories chamber predetermined oil levels. All components are intrinsically
Subject 2215. Separator shall bear UL-SU-2215 label. safe and enclosed in NEMA IV enclosures.
A sediment chamber to disperse flow and collect oily solids
Separator shall be designed in accordance with Stokes and sediments. Slotted pipe oil skimmer which can be manually adjusted to
Law and the American Petroleum Institute Publication 421, drain off precisely the amount of oil desired.
Monographs on Refinery Environmental Control - A sludge baffle to retain settleable solids and sediment
Management of Water Discharges, Design and Operation preventing them from entering the separation chamber. Effluent level controls to start and stop an explosion proof
of Oil-Water Separators. effluent pump and to activate audible and visual alarms at
An Oil Water Separation Chamber containing a removable predetermined levels in the effluent clearwell. All com-
Separator shall be the standard product of a steel tank inclined parallel corrugated plate coalescer to: ponents are intrinsically safe and enclosed in NEMA IV
manufacturer regularly engaged in the production of such shorten the vertical distance than an oil globule has to enclosures.
equipment. No subcontracting of tank fabrication shall be rise for effective removal.
permitted. enhance coalescence by generating a slight sinusoidal Consult Highland Tank for:
(wave like) flow pattern thereby causing smaller, slow Special coatings (interior or exterior)
Separator shall be fabricated, inspected and tested for rising oil globules to coalesce together on the undersides I-Beam Saddles or Skids
leakage before shipment from the factory as a completely of the plates forming larger, rapidly rising sheets of oil. Integral Oil Compartment
assembled vessel ready for installation. direct the paths of the separated oil to the surface of the Sludge Hopper
separator. Level Controls
Separator shall be rectangular, horizontal, atmospheric-type Heating Systems, Electric or Steam
steel vessel intended for the separation and storage of and a removable PETRO-SCREEN polypropylene Storage Tanks and Accessories
Stoystown, PA 15563 Manheim, PA 17545 Watervliet, NY 12189 Lebanon, PA 17042 Greensboro, NC 27407 Somersworth, NH 03878
TANK
814-893-5701 717-664-0600 518-273-0801 717-664-0602 910-218-0801 603-692-2012
. FAX 664-0617 FAX 273-1365 FAX 664-0631 FAX 218-1292 FAX 692-2014
M F G. C O FAX 893-6126
&