1. SITE DATA INFORMATION

SITE LOCATION RAMAGUNDAM, TELANGANA


NEAREST IMPORTANT TOWN RAMAGUNDAM
TOTAL AREA 155.14 Ha
EXISTING PLANT AREA 57 Ha
NEW PROPOSED PLANT AREA 47 Ha
GREEN BELT AREA 51 Ha
NEAREST APPROACH ROAD HIGHWAY (NH-563)/(SH-1)
DISTANCE FROM HIGHWAY 6 km
NEAREST RAIL HEAD RAMAGUNDAM RAILWAY STATION- 10 km
NEAREST PORT VISHAKHAPATTANAM
NEAREST AIRPORT RAMAGUNDAM AIRPORT
RAW WATER SOURCE GODAVARI RIVER
CONSTRUCTION WATER BORE WELL/TUBEWELL
POWER SOURCE POWER PLANT+GRID POWER
TREATED EFFLUENT DISPOSAL AS PER GUIDELINES OF STATUTORY
REQUIREMENT
STORM WATER DISPOSAL EXISTING NEARBY STORM WATER POINT
GENERAL TOPOGRAPHY OF AREA PLAIN
HIGH FLOOD LEVEL NOT PRONE TO FLOODING
PREDOMINANT WIND DIRECTION(S) FROM South TO North
DESIGN RAINFALL INTENSITY (MM/HR) 60 mm/hr
RAINY SEASON JUNE TO SEPTEMBER

2. METEOROLOGICAL DESIGN DATA:

S. No Parameter Unit Min Nor Max Design


1 Barometric mbar 1000 1018.6
pressure
2 Ambient DegC 8.4 36.6 46.8
temperature
3 Relative humidity % 11 87 98
@ ambient
temperature
4 Total rainfall, mm mm 658 1227.2
per year
5 Rainfall data for 24 mm 111.7 138.2
hr period
6 Wind velocity Km/hr 0 44

Format No. EIL-1641-540 Rev. 1 Copyright EIL All rights reserved

Page 1338 of 1345


DOCUMENT No.
SITE & UTILITY DATA A747-00-83-41-SD-001
Page 3 of 3

3. GENERAL PARAMETER:

Parameter UOM Design value


Elevation m 152
Wind direction From south

4. DATA FOR EQUIPMENT DESIGN:

S. Parameter UOM Design value


No
1 Dry bulb temperature DEGC 44.4
2 Wet bulb temperature DEGC 30
3 Ambient temperature for MDMT DEGC 8.4
4 Air temperature for air cooled exchangers DEGC 46.8
where followed by water cooling
5 Air temperature for air cooled exchangers DEGC 46.8
where not followed by water cooling
6 DEGC 46.8
7 Coincident temperature and relative humidity DEGC 42.5 DEGC & 65%
for air blower/air compressor design
8 Coincident temperature and relative humidity DEGC 42.5 DEGC & 65%
for air GTG design
9 Air temperature for prilling tower DEGC 46.8
10 Earthquake design factor (Code IS-1893 DEGC Site specific seismic
Zone-III/Site spectra whichever is governing. spectra

Format No. EIL-1641-540 Rev. 1 Copyright EIL All rights reserved