Maintenance Handbook
9YZ-03803-1240-PCZZA
Issue 5 | July 2012
Legal notice
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2012 Alcatel-Lucent. All rights reserved.
Note:
1 Safety Information
2 Hardware Presentation
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC iii
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Contents
....................................................................................................................................................................................................................................
3 Safety Rules and Precautions
Fan Tray
Air Filter
Front RITs
....................................................................................................................................................................................................................................
iv Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Contents
....................................................................................................................................................................................................................................
Remove SFP Module ............................................................................................................................................................ 4-48
4-48
Rear RITs
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC v
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Contents
....................................................................................................................................................................................................................................
Before You Start
Replace JBXPEM
7 Software Procedures
....................................................................................................................................................................................................................................
vi Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Contents
....................................................................................................................................................................................................................................
Modify Community String Name
Reset BSC
Modify BSC IP Configuration from Two LANs to One LAN ............................................................................... 7-19
7-19
8 Upgrade Firmware
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC vii
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Contents
....................................................................................................................................................................................................................................
Upgrade MUX and TP Firmware
Upgrade TP Firmware
....................................................................................................................................................................................................................................
viii Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
List of tables
6-3 Cable List for GE Links between LIU and ATCA ......................................................................................... 6-7
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC ix
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
List of tables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
x Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
List of figures
4-4 Fan Unit Cover for ATCA Shelf Variants Before 3BK 27291 ABxx ................................................... 4-12
4-5 Fan Unit Cover fromr ATCA Shelf Variant 3BK 27291 ABxx On ....................................................... 4-13
4-6 Fan Unit Cover for ATCA Shelf Variants Before 3BK 27291 ABxx ................................................... 4-16
4-7 Fan Unit Cover from ATCA Shelf Variant 3BK 27291 ABxx On ......................................................... 4-17
4-8 ATCA Front Board Handles - First Step to Remove a Board ................................................................. 4-26
4-9 ATCA Front Board Handles - Second Step to Remove a Board ............................................................ 4-27
4-13 Protect EMI Stripes when Inserting / Removing Boards ......................................................................... 4-31
4-17 JAXPC: Shelf Geographic Address Rotary Switches for Board Variant Before 3BK 27226 AACA
............................................................................................................................................................................ 4-744-74
4-74
4-18 JAXPC: Shelf Geographic Address Rotary Switches from Board Variant 3BK 27226 AACA On
............................................................................................................................................................................ 4-754-75
4-75
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC xi
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
List of figures
....................................................................................................................................................................................................................................
4-20 Shelf Manager Board ............................................................................................................................................. 4-87
4-22 Power Entry Module for Variants Before 3BK 27342 AACA ............................................................... 4-93
4-23 Power Entry Module from Variant 3BK 27342 AACA On ..................................................................... 4-94
....................................................................................................................................................................................................................................
xii Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
About this document
About this document
Purpose
This handbook describes how to replace units and cables in the subracks and how to
install, configure and change 9130 BSC Evolution software.
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC xiii
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
About this document
....................................................................................................................................................................................................................................
Intended audience
This Maintenance Handbook is intended for:
Maintenance engineers
System support engineers
Network technicians
Network operators.
Supported systems
This document applies to Release B12 of the BSS.
Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.
Prerequisites
You must have a basic understanding of the following:
Alcatel-Lucent operations and maintenance (O&M) concepts for the BSC
BSC hardware configurations
Telecommunications engineering
Anti-static procedures
Windows environment
Linux environment.
Conventions used
This section gives information on conventions.
Vocabulary conventions
None.
....................................................................................................................................................................................................................................
xiv Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
About this document
....................................................................................................................................................................................................................................
Typographical conventions
The following typographical conventions are used in this document:
Appearance Description
Italicized text Emphasized information.
graphical user interface text Text that is displayed in a graphical user interface or in a
hardware label.
Document reference, reference Related document that is referenced in the document.
number
Related information
None.
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
1-888-582-3688 (for the United States)
1-317-377-8618 (for all other countries)
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-
lucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC xv
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
xvi Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
1 Safety Information
1
General structure
Safety statements include the following structural elements:
B C D
CAUTION
M P L E
Lifting hazard E F
SA
Lifting this equipment by yourself can result in injury
due to the size and weight of the equipment.
G
Always use three people or a lifting device to transport
and position this equipment. [ABC123]
H
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
(optional)
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
injury
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 1-1
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Safety Information Structure of safety statements
....................................................................................................................................................................................................................................
Signal words
The signal words identify the hazard severity levels as follows:
....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
2 Hardware Presentation
2
Overview
Purpose
This section provides an overview of equipment and interconnections.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 2-1
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Hardware Presentation 9130 BSC Evolution Front and Rear Views
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Hardware Presentation 9130 BSC Evolution Front and Rear Views
....................................................................................................................................................................................................................................
The following figure shows the rear view for a standalone 9130 BSC Evolution.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 2-3
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Hardware Presentation 9130 BSC Evolution Front and Rear Views
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-4 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Hardware Presentation 9130 BSC Evolution Front and Rear Views
....................................................................................................................................................................................................................................
The BSC is connected with the following network elements for telecom functions:
MFS, TC: Ater Mux interface
MSC: A interface
BTS: Abis interface.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 2-5
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Hardware Presentation Board/Area/Slot/SBL Mapping
....................................................................................................................................................................................................................................
Board/Area/Slot/SBL Mapping
Overview
The following tables give the board/area/slot/SBL mapping for the modules used in the
9130 BSC Evolution.
Table 2-1 ATCA Shelf Front View Board-Area-Slot-SBL Mapping
JBXFAN area
Board JBXFAN1 JBXFAN2
Slot number 81 82
SBL FAN1 FAN2
Board JBXFAN3 JBXFAN4
Slot number 83 84
SBL FAN3 FAN4
Slot area
Board J J J J J J J J J J J J J J
B B B B B B B B B B B B B B
X X X X X X X X X X X X X X
T T C C C O S S O C C C C C
P P C C C M S S M C C C C C
1 2 P P P C W W C P P P P P
* * 6 4 1 P 1 2 P 2 3 5 7 8
1 2
Physical slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14
number
Logical slot 13 11 9 7 5 3 1 2 4 6 8 10 12 14
number
SBL T T C C C C S S C C C C C C
P P P P P P S S P P P P P P
- - - - - - W W - - - - - -
H H H H H H - - H H H H H H
W W W W W W H H W W W W W W
1 2 8 6 3 1 W W 2 4 5 7 9 10
1 2
....................................................................................................................................................................................................................................
2-6 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Hardware Presentation Board/Area/Slot/SBL Mapping
....................................................................................................................................................................................................................................
Notes:
1. * JBXTP3I for IPoverE1 mode
2. * JBXTP3I4 for AUPoIP mode
Rear area
Board ... JAXSSW2 JAXSSW1 ...
Physical slot 14 ... 8 7 ... 1
number
Logical slot number 30 ... 24 23 ... 17
SBL SSW-HW2 SSW-HW1
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 2-7
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Hardware Presentation Board/Area/Slot/SBL Mapping
....................................................................................................................................................................................................................................
Table 2-3 LIU Shelf Board-Slot-SBL Mapping (continued)
....................................................................................................................................................................................................................................
2-8 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
3 S3afety Rules and
Precautions
Overview
Purpose
This section contains the following information:
This section contains the following information:
Safety rules for equipment under power
Electrostatic precautions.
Contents
DANGER
Electric-shock hazard
Possible death or serious physical harm to personnel and damage to equipment may
result from mishandling the equipment.
While performing any maintenance tasks or procedures, you must follow any local safety
requirements, and in particular, those mentioned in this section.
For maintenance purposes, field operators may have to work on equipment under power
(-48 VDC or -60 VDC). This means that it is possible to touch some parts under power
that are only protected by heavy fuses. Maintenance activities must be carried out
carefully to avoid short circuits and to prevent serious personal injury.
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 3-1
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Safety Rules and Precautions Safety Rules for Equipment Under Power
....................................................................................................................................................................................................................................
Injury from working with optical power
The laser beam used in optical communication is invisible and can seriously damage the
eyes, therefore:
Never look into a fiber with a laser coupled on it
If eyes are accidentally exposed to the laser beam, immediately call for medical
assistance.
Conductive Objects: Remove all conductive objects from hands and arms such as rings,
bracelets, metallic wrist watches or similar. Use appropriate insulated tools for
maintenance activities.
Mobile Telephone: Do not use a mobile telephone when the BSC doors are open. It can
interfere with the operation of the BSC.
Uncommon Replacements: Alcatel-Lucent will perform a case-by-case study and, if
necessary, prepare a special replacement procedure. Any such procedure is handled solely
by Alcatel-Lucent.
Electrostatic Precautions
Environment
You must observe the following electrostatic precautions:
Ensure that work benches, tools, and floor mats have a conducting surface connected
to ground. Before handling static-sensitive components and assemblies, ground
yourself to the conducting surface by using an anti-static wrist strap.
When handling static-sensitive components and assemblies, do not wear or use
clothes made of wool, nylon or any other synthetic material. Such fabrics are major
sources of static build-up.
When handling static-sensitive components and assemblies, do not use gloves and
finger covers, unless they are made of cotton.
Tools
You need the following tools to perform the procedures described in this handbook:
An anti-static wrist strap
A serviceable replacement unit
A Torx screwdriver
A Flathead screwdriver
A Philips crosshead screwdriver.
....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Safety Rules and Precautions Electrostatic Precautions
....................................................................................................................................................................................................................................
You must respect the following rules:
Ensure that all the tools which come into contact with static-sensitive components are
at the same voltage level as the conducting work surfaces and floor mats.
These tools include soldering irons, oscilloscopes, power supplies, and metal parts of
tools and fixtures that are used to hold, assemble or test PBAs.
Do not use rough cleaners or erasers to clean the gold-plated contacts on PBAs
Do not mark a PBA with a lead pencil or any other writing instrument
Do not use synthetic brushes to clean equipment, and do not use dry cleaning
methods.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 3-3
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Safety Rules and Precautions Electrostatic Precautions
....................................................................................................................................................................................................................................
Do not touch PBA connection pins or conductor paths
Do not touch PBAs with wet hands
Place PBAs that have been removed during maintenance with the soldered side
downwards on a conductive surface
Do not scratch or rub the soldered side of a PBA with a sharp or rough object
Do not repair PBAs in the switch room
Do not handle components and assemblies by their leads
Do not use excessive force when inserting connection boards.
....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
4 Maintain ATCA Subrack
4
Overview
Purpose
This section covers replacement of the following ATCA subrack RITs:
Fan Unit
Replace the:
Upper Fan Tray
Lower Fan Tray.
Front RITs:
Replace the:
JBXOMCP - O&M control board
JBXSSW - Gigabit Ethernet Switch board
JBXTP - GPRS radio processing board
JBXTP3I - GPRS radio processing board for IP mode
JBXFILL - Front filler
Air Filter.
Replace the:
JBXOMCP - O&M control board
JBXSSW - Gigabit Ethernet Switch board
JBXTP - GPRS radio processing board
JBXFILL - Front filler
Air Filter.
Rear RITs:
Replace the:
JAXPC - Personality card
JAXSSW - Gigabit Ethernet Switch Rear Transition Module
JBXPEM - Power Entry Module
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-1
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Overview
....................................................................................................................................................................................................................................
JAXSMM - Shelf manager
JAXFILL - Rear filler.
In addition to the RIT replacements, this section describes how to perform an ATCA
subrack extension in order to increase the BSC capacity.
Contents
....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-3
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Checks
Before You Start
....................................................................................................................................................................................................................................
Checks
Checklist
You must check the following:
System impact
As long as only one unit is removed and replaced at any one time, there is no impact
on the system. This is because redundancy is built into the components of the ATCA
Subrack.
In a standard configuration, the upper ATCA Subrack is empty. In a pre-equipped
configuration, the lower subrack contains a full set of units. The procedures described
here apply to both subracks.
For preventive maintenance.
Only replace RITs on the ATCA Subrack, if the BSC terminal displays alarm signals
for them.
....................................................................................................................................................................................................................................
4-4 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack ATCA Subrack Presentation
ATCA Subrack Description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-5
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack ATCA Subrack Presentation
ATCA Subrack Description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-6 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack ATCA Subrack Presentation
ATCA Subrack Description
....................................................................................................................................................................................................................................
The following figure shows the ATCA subrack rear view in the case of a 9130 BSC
Evolution for any configuration.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-7
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack ATCA Subrack Presentation
ATCA Subrack Description
....................................................................................................................................................................................................................................
Important information
CAUTION
Damage to Equipment
Operating the system without fillers causes overheating of system components.
Unused slots, front and rear, must be equipped with fillers.
The fillers are used to create the appropriate air flow within the subrack.
....................................................................................................................................................................................................................................
4-8 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Manage Fan Tray
Fan Tray
....................................................................................................................................................................................................................................
Fan Tray
CAUTION
Damage to Equipment
Running the system longer than 30 seconds with less than three blowers damages the
system.
If you exchange a fan tray in a running system ensure that the exchange procedure is
finished within 1 minute.
A fan cover in a running system can not be removed more than 1 minute.
Prerequisites
Important information
DANGER
Laceration hazard
Inserting tools or fingers into operational fans may cause injuries.
When removing a fan tray, pay attention to rotating fans. Fans become exposed when the
fan tray is pulled. Keep clear of the fans as long as they are rotating.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-9
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Prerequisites
Fan Tray
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-10 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace Fan Tray
Fan Tray
....................................................................................................................................................................................................................................
3 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-11
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace Fan Tray
Fan Tray
....................................................................................................................................................................................................................................
Figure 4-4 Fan Unit Cover for ATCA Shelf Variants Before 3BK 27291 ABxx
From ATCA shelf variant 3BK 27291 ABxx on, pull the clips on the left and right-hand
side of the cover up then pull the cover down and hold it down during the exchange
procedure.
....................................................................................................................................................................................................................................
4-12 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace Fan Tray
Fan Tray
....................................................................................................................................................................................................................................
Figure 4-5 Fan Unit Cover fromr ATCA Shelf Variant 3BK 27291 ABxx On
...................................................................................................................................................................................................
8 If the replacement fan should be installed in rear position, fix the appropriate handle to
the fan unit with the four screws.
...................................................................................................................................................................................................
10 Check that the exhaust flap is open (visible at the rear of the chassis).
...................................................................................................................................................................................................
15 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that firmware
upgrade is necessary.
You must:
From a local terminal open a telnet session on the active OMCP:
telnet 172.17.y.x
Where:
y is 3 for ATCA shelf 3
y is 4 for ATCA shelf 4
x is 30 for JBXOMCP1 (ATCA physical slot 6)
x is 40 for JBXOMCP2( ATCA physical slot 9).
Type the username and the password:
root
....................................................................................................................................................................................................................................
4-14 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace Fan Tray
Fan Tray
....................................................................................................................................................................................................................................
alcatel
Perform Step 2 to Step 3 from Upgrade FAN Firmware (p. 8-26).
The FIRMWARE-INCOMPATIBILITY alarm is raised, perform the corrective action
from [99,9] FIRMWARE-INCOMPATIBILITY
There is no firmware alarm after the blade is IT/FIT, it means firmware level is up to
date.
...................................................................................................................................................................................................
16 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
2 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-15
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace Fan Tray
Fan Tray
....................................................................................................................................................................................................................................
Figure 4-6 Fan Unit Cover for ATCA Shelf Variants Before 3BK 27291 ABxx
From ATCA shelf variant 3BK 27291 ABxx on, pull the clips on the left and right-hand
side of the cover up, then pull the cover down and hold it down during the exchange
procedure.
....................................................................................................................................................................................................................................
4-16 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace Fan Tray
Fan Tray
....................................................................................................................................................................................................................................
Figure 4-7 Fan Unit Cover from ATCA Shelf Variant 3BK 27291 ABxx On
...................................................................................................................................................................................................
7 If the replacement fan should be installed in rear position, fix the appropriate handle to
the fan unit with the four screws.
...................................................................................................................................................................................................
9 Check that the exhaust flap is open (visible at the rear of the chassis).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-17
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace Fan Tray
Fan Tray
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
12 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that firmware
upgrade is necessary:
You must:
From a local terminal, open a telnet session on the active OMCP:
telnet 172.17.y.x
where:
y is 3 for ATCA shelf 3
y is 4 for ATCA shelf 4
x is 30 for JBXOMCP1 (ATCA physical slot 6)
x is 40 for JBXOMCP2( ATCA physical slot 9).
Type the username and the password:
root
alcatel
Perform Step 2 to Step 3 from Upgrade FAN Firmware (p. 8-26).
The alarm FIRMWARE-INCOMPATIBILITY is raised, perform the corrective action
from [99,9] FIRMWARE-INCOMPATIBILITY
There is no firmware alarm after blade is IT/FIT, it means firmware level is up to date.
...................................................................................................................................................................................................
13 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-18 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Manage Air Filter
....................................................................................................................................................................................................................................
Air Filter
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-19
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Air Filter Replacement
Air Filter
....................................................................................................................................................................................................................................
Air Filter Replacement for ATCA Shelf Variants 3BK 27291 AAxx
Replace the air filter:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
3 Locate the two tabs on the lower front of the filter frame.
The two tabs are symmetric to the center of the shelf.
....................................................................................................................................................................................................................................
4-20 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Air Filter Replacement
Air Filter
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Push the tabs to rear of the shelf and pull the filter down.
...................................................................................................................................................................................................
6 Insert the new filter (with filter frame tabs in forward position and pointing down).
...................................................................................................................................................................................................
8 Raise the filter up and into the lower card guide tray and release.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-21
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Air Filter Replacement
Air Filter
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
10 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
Air Filter Replacement for ATCA Shelf Variants 3BK 27291 ABxx or Newer
Replace the air filter:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
3 Push the frame of the filter to rear of the shelf and pull the filter down.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-22 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Air Filter Replacement
Air Filter
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Raise the filter up and into the lower card guide tray and release.
...................................................................................................................................................................................................
9 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-23
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Manage Front RITs
Front RITs
....................................................................................................................................................................................................................................
Front RITs
....................................................................................................................................................................................................................................
4-24 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Tips for Inserting ATCA Front RITs
Front RITs
....................................................................................................................................................................................................................................
2 Move the ejector handles outwards. The blue LED blinks indicating that the board power
OFF process is ongoing.
The following figure shows the first step to perform when removing a board.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-25
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Tips for Inserting ATCA Front RITs
Front RITs
....................................................................................................................................................................................................................................
Figure 4-8 ATCA Front Board Handles - First Step to Remove a Board
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-26 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Tips for Inserting ATCA Front RITs
Front RITs
....................................................................................................................................................................................................................................
Second Step to Remove a Board
The following figure shows the second step to perform when removing a board.
Figure 4-9 ATCA Front Board Handles - Second Step to Remove a Board
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-27
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Tips for Inserting ATCA Front RITs
Front RITs
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-28 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Tips for Inserting ATCA Front RITs
Front RITs
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-29
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Tips for Inserting ATCA Front RITs
Front RITs
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-30 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Tips for Inserting ATCA Front RITs
Front RITs
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-31
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP/JBXTP3
Front RITs
....................................................................................................................................................................................................................................
Replace JBXTP/JBXTP3
Overview
Attention: This procedure applies for replacement of:
JBXTP with JBXTP
JBXTP3 with JBXTP3.
Do not apply this procedure to replace JBXTP with JBXTP3. For this case, refer to
Replace JBXTP with JBXTP3 (p. 4-40).
Replacement of JBXTP3 with JBXTP is not allowed.
When inserting/removing the JBXTP/JBXTP3, wait at least 30 seconds before
another insert/remove operation.
Remove JBXTP/JBXTP3
Remove a JBXTP board:
...................................................................................................................................................................................................
2 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
3 Identify the board to be replaced. Refer to Board/Area/Slot/SBL Mapping (p. 2-6) for
more information.
...................................................................................................................................................................................................
6 Perform this step only when JBXTP3 is equipped with a working SFP module.
You must:
Carefully remove the optical cable from the SFP module. Pay attention since the
optical cable is fragile
Open the SFP hinged face to approximately ninety degrees and then grasp the hinged
face and carefully pull the SFP straight out of the slot.
....................................................................................................................................................................................................................................
4-32 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP/JBXTP3
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
8 Move slowly the ejector handles outwards until you feel resistance.
...................................................................................................................................................................................................
Insert JBXTP/JBXTP3
Insert a JBXTP board:
...................................................................................................................................................................................................
1 Ensure that the top and bottom ejector handles are in the outward position.
...................................................................................................................................................................................................
2 Insert board into the shelf by placing the top and bottom edges of the board in the card
guides of the shelf. Ensure that the guiding module of shelf and board are aligned
properly.
...................................................................................................................................................................................................
3 Slide the board into the shelf until you feel resistance. The blue LED is illuminated.
...................................................................................................................................................................................................
4 Simultaneously move the top and bottom ejector handles to the inward position to lock
the board to the shelf.
Wait one minute until the blue LED is illuminated permanently.
...................................................................................................................................................................................................
5 Perform this task only when JBXTP3 is equipped with a working SFP module.
You must:
Insert the SFP module straight into the slot until the module clicks firmly into place.
When inserting the SFP, be sure that the hinged face is closed
Connect the optical cable on the SFP module.
...................................................................................................................................................................................................
6 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
8 From the BSC terminal or OMC-R, unlock the JBXTP board; the blue LED is switched
OFF.
...................................................................................................................................................................................................
9 From the BSC terminal or OMC-R, check the report to see if the board is operational.
...................................................................................................................................................................................................
11 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-34 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
Replace JBXTP3I
Overview
Attention: This procedure applies for replacement of JBXTP3I with JBXTP3I and
JBXTP3I4 with JBXTP3I4.
Replacement of JBXTP3I with JBXTP/JBXTP3 is not allowed.
When inserting/removing JBXTP3I, wait at least 30 seconds before another
insert/remove operation.
For BSC platform of B12.1 with AUPoIP feature enabled, before JBXTP3I4 delivered
to filed and inserted into platform, make sure version of TPIP FPGA is not H'D01D,
otherwise the JBXTP3I4 will reboot in loop. The only way to recover it is to contact
ALU support, get patch from R&D, and perform TPIP firmware upgrade with the
patch. FPGA H'401B is strongly recommended to be writen into TPIP before going to
the field.
For BSC platform of B12.1Ed2 or later version with AUPoIP feature enabled, FPGA
H'4023 is recommended to be writen into TPIP of JBXTP3I4 before going to the field.
Otherwise, TPIP firmware upgrade must be performed to support stable CS traffic.
Remove JBXTP3I
Remove a JBXTP3I board:
...................................................................................................................................................................................................
2 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
3 Identify the board to be replaced. Refer to Board/Area/Slot/SBL Mapping (p. 2-6) for
more information.
...................................................................................................................................................................................................
6 Perform this step only when JBXTP3I is equipped with a working SFP module.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-35
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
You must:
Carefully remove the optical cable from the SFP module. Pay attention since the
optical cable is fragile
Open the SFP hinged face to approximately ninety degrees and then grasp the hinged
face and carefully pull the SFP straight out of the slot.
...................................................................................................................................................................................................
8 Move slowly the ejector handles outwards until you feel resistance.
...................................................................................................................................................................................................
Insert JBXTP3I
Insert a JBXTP3I board:
...................................................................................................................................................................................................
1 Ensure that the top and bottom ejector handles are in the outward position.
...................................................................................................................................................................................................
2 Insert board into the shelf by placing the top and bottom edges of the board in the card
guides of the shelf. Ensure that the guiding module of shelf and board are aligned
properly.
...................................................................................................................................................................................................
3 Slide the board into the shelf until you feel resistance.
Result: The blue LED is illuminated.
...................................................................................................................................................................................................
4 Simultaneously move the top and bottom ejector handles to the inward position to lock
the board to the shelf.
Wait one minute until the blue LED is illuminated permanently.
...................................................................................................................................................................................................
5 Perform this step only when JBXTP3I is equipped with a working SFP module.
....................................................................................................................................................................................................................................
4-36 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
You must:
Insert the SFP module straight into the slot until the module clicks firmly into place.
When inserting the SFP, be sure that the hinged face is closed
Connect the optical cable on the SFP module.
...................................................................................................................................................................................................
6 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
8 From the BSC terminal or OMC-R, unlock the JBXTP board; the blue LED is switched
OFF.
...................................................................................................................................................................................................
10 From the BSC terminal or OMC-R, check the report to see if the board is operational.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-37
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
If the MAC addrees is wrong, update it:
Connect on the active OMCP:
telnet 172.17.33.1
Type the username and the password
In a telnet window session, connect on the target JBXTP3I board:
telnet 172.16.3.x where x is 110 for TP2 and 130 for TP1
Type the username and the password
On JBXTP3I, go under tux by typing /usr/local/tpgsm/tools/tux and perform
the following commands:
ipmc info
If the displayed JAXIP MAC address is not the correct one (for example, it is
inverted):
ipmc mac3= <new MAC address>
rri FIA_MX
ipmc info
Close all telnet connections.
...................................................................................................................................................................................................
12 Check that both the JAXIP and JGXEOE MAC address are not the same.
To do so:
To check the JAXIP MAC address, connect on the active OMCP:
telnet 172.17.33.1
Type the username and the password
In the telnet window session, connect on the target JBXTP3I board:
telnet 172.16.3.x where x is 110 for TP2 and 130 for TP1
On JBXTP3I, go under tux by typing /usr/local/tpgsm/tools/tux and perform
the following commands:
ipmc info
MAC address 3 for JAXIP Ethernet : xx:xx:xx:xx:xx:xx
Close all telnet connections.
To check the JGXEOE MAC address, connect on the active OMCP:
telnet 172.17.33.1
Type the username and the password
In telnet window session, connect on the target nE1oE module of the JBXTP3I board:
telnet 172.16.35.x where x is 110 for TP2 and 130 for TP1
Type the username and the password
On nE1oE module of the JBXTP3I, perform the following commands:
ri JBXTPGSM r 0x1AC
ri - Read : xx xx xx xx xx zt FF FF FF FF FF FF FF FF FF FF
....................................................................................................................................................................................................................................
4-38 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
If the JGXEOE MAC address is same as the JAXIP MAC address:
Change the JGXEOE MAC address to JAXIP MAC@ - 1
ri JBXTPGSM w 0x1B1 0xvw where 0xvw=0xzt-1
ri - Write at address B1 : vw
ri - Write OK
Check the new address:
ri JBXTPGSM r 0x1AC
ri - Read : xx xx xx xx xx vw FF FF FF FF FF FF FF FF FF FF
Close all telnet connections.
...................................................................................................................................................................................................
13 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-39
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP with JBXTP3
Front RITs
....................................................................................................................................................................................................................................
Procedure
Replace a JBXTP board by a JBXTP3 board:
...................................................................................................................................................................................................
2 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
3 Identify the board to be replaced. Refer to Board/Area/Slot/SBL Mapping (p. 2-6) for
more information.
...................................................................................................................................................................................................
7 Move slowly the ejector handles outwards until you feel resistance.
....................................................................................................................................................................................................................................
4-40 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP with JBXTP3
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
8 By moving the ejector handles outwards, remove the JBXTP board from shelf.
...................................................................................................................................................................................................
9 Ensure that the top and bottom ejector handles of the new JBXTP3 board are in the
outward position.
...................................................................................................................................................................................................
10 Insert the JBXTP3 board into the shelf by placing the top and bottom edges of the board
in the card guides of the shelf. Ensure that the guiding module of shelf and board are
aligned properly.
...................................................................................................................................................................................................
11 Slide the board into the shelf until you feel resistance.
Result: The blue LED is illuminated.
...................................................................................................................................................................................................
12 Simultaneously move the top and bottom ejector handles to the inward position to lock
the board to the shelf.
Wait one minute until the blue LED is illuminated permanently.
...................................................................................................................................................................................................
13 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
16 Wait until the blue LED is switched OFF. The switched OFF blue LED indicates that the
board is operational.
...................................................................................................................................................................................................
20 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-42 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP/JBXTP3 with JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
Procedure
Replace a JBXTPJ/BXTP3 board with a JBXTP3I board:
...................................................................................................................................................................................................
2 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
3 Identify the board to be replaced. Refer to Board/Area/Slot/SBL Mapping (p. 2-6) for
more information.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-43
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP/JBXTP3 with JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Perform this step only when JBXTP3I is equipped with working SFP module.
You must:
Carefully remove the optical cable from the SFP module. Pay attention since the
optical cable is fragile
Open the SFP hinged face to approximately ninety degrees and then grasp the hinged
face and carefully pull the SFP straight out of the slot.
...................................................................................................................................................................................................
8 Move slowly the ejector handles outwards until you feel resistance.
...................................................................................................................................................................................................
9 By moving the ejector handles outwards, remove the JBXTP/JBXTP3 board from shelf.
...................................................................................................................................................................................................
10 Ensure that the top and bottom ejector handles of the new JBXTP3I board are in the
outward position.
...................................................................................................................................................................................................
11 Insert the JBXTP3I board into the shelf by placing the top and bottom edges of the board
in the card guides of the shelf. Ensure that the guiding module of shelf and board are
aligned properly.
...................................................................................................................................................................................................
12 Slide the board into the shelf until you feel resistance.
Result: The blue LED is illuminated.
...................................................................................................................................................................................................
13 Simultaneously move the top and bottom ejector handles to the inward position to lock
the board to the shelf.
Wait one minute until the blue LED is illuminated permanently.
....................................................................................................................................................................................................................................
4-44 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP/JBXTP3 with JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
14 Perform this step only when JBXTP3I is equipped with a working SFP module.
You must:
Insert the SFP module straight into the slot until the module clicks firmly into place.
When inserting the SFP, be sure that the hinged face is closed
Connect the optical cable on the SFP module.
...................................................................................................................................................................................................
15 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
17 From the BSC terminal or OMC-R, unlock the JBXTP board, the blue LED is switched
OFF.
...................................................................................................................................................................................................
19 From the BSC terminal or OMC-R, check the report to see if the board is operational.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-45
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP/JBXTP3 with JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
21 Check the both JAXIP and JGXEOE MAC address are not the same.
To do so:
To check the JAXIP MAC address, connect on the active OMCP:
telnet 172.17.33.1
Type the username and the password
In the telnet window session, connect on the target JBXTP3I board:
telnet 172.16.3.x where x is 110 for TP2 and 130 for TP1
On JBXTP3I, go under tux by typing /usr/local/tpgsm/tools/tux and perform
the following commands:
ipmc info
MAC address 3 for JAXIP Ethernet : xx:xx:xx:xx:xx:xx
Close all telnet connections.
To check the JGXEOE MAC address, connect on the active OMCP:
telnet 172.17.33.1
Type the username and the password
In telnet window session, connect on the target nE1oE module of the JBXTP3I board:
telnet 172.16.35.x where x is 110 for TP2 and 130 for TP1
Type the username and the password
On nE1oE module of the JBXTP3I, perform the following commands:
....................................................................................................................................................................................................................................
4-46 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXTP/JBXTP3 with JBXTP3I
Front RITs
....................................................................................................................................................................................................................................
ri JBXTPGSM r 0x1AC
ri - Read : xx xx xx xx xx zt FF FF FF FF FF FF FF FF FF FF
If the JGXEOE MAC address is the same as the JAXIP MAC address:
Change the JGXEOE MAC address to JAXIP MAC@ - 1
ri JBXTPGSM w 0x1B1 0xvw where 0xvw=0xzt-1
ri - Write at address B1 : vw
ri - Write OK
Check the new address:
ri JBXTPGSM r 0x1AC
ri - Read : xx xx xx xx xx vw FF FF FF FF FF FF FF FF FF FF
Close all telnet connections.
...................................................................................................................................................................................................
24 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-47
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Remove SFP Module
Front RITs
....................................................................................................................................................................................................................................
2 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
5 From the BSC Terminal or OMC-R, lock the SFP module. The SBL associated to SFP
module is STM1-TTP (from 1 to 8).
The SFP modules from 1 to 4 are on the first JBXTP board and 5 to 8 to the second
JBXTP board.
Result: The fibre is switched off.
...................................................................................................................................................................................................
6 Carefully remove the optical cable from the SFP module. Be attentive, do not harm it.
...................................................................................................................................................................................................
7 Open the SFP hinged face to approximately ninety degrees and then grasp the hinged face
and carefully pull the SFP straight out of the slot.
...................................................................................................................................................................................................
9 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-48 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert SFP Module
Front RITs
....................................................................................................................................................................................................................................
2 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
4 Replace the protective rubber from the new SFP module and insert straight into the slot
until the module clicks firmly into place. When inserting the SFP, ensure that the hinged
face is closed.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-49
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert SFP Module
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 From the BSC Terminal or OMC-R, unlock the SFP module. The SBL associated to SFP
module is STM1-TTP (from 1 to 8).
The SFP modules from 1 to 4 are on the first JBXTP board and 5 to 8 to the second
JBXTP board.
....................................................................................................................................................................................................................................
4-50 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert SFP Module
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
8 From the BSC Terminal, perform a Display Section and Path Trace to check link
connections.
...................................................................................................................................................................................................
9 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-51
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXOMCP
Front RITs
....................................................................................................................................................................................................................................
Replace JBXOMCP
Remove JBXOMCP
If the replacement of the board is not done due to a board hardware malfunction,
and the board telnet connection is possible, then before Remove Board (p. 4-54),
perform:
JBXOMCP Takeover (p. 4-52), ONLY if the board to be replaced is the active one
Erase HDD (p. 4-53).
Tip: The active OMCP is the one with the ACT or USR2 LED ON.
Attention: Before replacing the JBXOMCP board, check and write down the status of
the system. Ensure that the status for all degraded SBLs and functions and all alarms
is available before starting the action.
JBXOMCP Takeover
Perform a JBXOMCP takeover ONLY if the board to be replaced is the active one:
...................................................................................................................................................................................................
1 Start the 9130 BSC Evolution Terminal software. Refer to Start the Terminal Software
from the 9130 BSC Evolution Terminal User Guide.
...................................................................................................................................................................................................
4 After the takeover is done, check the ACT or USR2 LED status on the OMCPs front
panel.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-52 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXOMCP
Front RITs
....................................................................................................................................................................................................................................
Erase HDD
Erase the HDD of the board:
...................................................................................................................................................................................................
4 From the BSC terminal or from the OMC-R, disable/lock the JBXOMCP board.
When the command is completed, the blue LED switches ON and the board can be
removed.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-53
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXOMCP
Front RITs
....................................................................................................................................................................................................................................
Remove Board
Remove a JBXOMCP board:
...................................................................................................................................................................................................
1 Identify the board to be replaced. Refer to Board/Area/Slot/SBL Mapping (p. 2-6) for
more information.
...................................................................................................................................................................................................
3 Unfasten screws of front plate until the board is detached from the shelf.
...................................................................................................................................................................................................
Insert JBXOMCP
Insert a JBXOMCP board:
...................................................................................................................................................................................................
1 Ensure that the top and bottom ejector handles are in the outward position.
...................................................................................................................................................................................................
2 Insert board into the shelf by placing the top and bottom edges of the board in the card
guides of the shelf. Ensure that the guiding module of shelf and board are aligned
properly.
...................................................................................................................................................................................................
3 Slide the board into the shelf until you feel resistance.
...................................................................................................................................................................................................
5 Simultaneously move the top and bottom ejector handles to the inward position.
....................................................................................................................................................................................................................................
4-54 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXOMCP
Front RITs
....................................................................................................................................................................................................................................
Result: The blue LED blinks. After some seconds, the blue LED is switched OFF.
...................................................................................................................................................................................................
6 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
8 If the disable/lock operation was successful during the JBXOMCP board removal, wait
until the blue LED is illuminated again then continue with next step.
If the disable/lock operation was unsuccessful during JBXOMCP board removal, move
the bottom ejector handle to outward position, wait until the blue LED is illuminated
again, and then continue with next step.
...................................................................................................................................................................................................
9 Connect the Ethernet cable from the Local PC to the JAXSSW1 port ETH 8 in
corresponding ATCA shelf.
...................................................................................................................................................................................................
10 Open a DOS console window. Connect to the new JBXOMCP board through SHMC as
follows.
To do so:
Under Windows 2000, the connection is done as follows:
telnet
set term vt100
open 172.17.y.8 450x
Under Windows XP/Vista/Windows 7, the connection is done as follows:
NOTE: The support for Windows 7 is available starting with MR3Ed1.3.
telnet 172.17.y.8 450x
Where:
y is 3 for ATCA shelf 3
y is 4 for ATCA shelf 4
x is 3 for JBXOMCP1
x is 4 for JBXOMCP2.
...................................................................................................................................................................................................
11 If the disable/lock operation was successful during JBXOMCP board removal, from the
BSC terminal or OMC-R, initialize/unlock the corresponding JBXOMCP board.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-55
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXOMCP
Front RITs
....................................................................................................................................................................................................................................
Result: The blue LED is switched OFF.
If the disable/lock operation was unsuccessful during JBXOMCP board removal,
move the bottom ejector handle to the inward position.
The blue LED is switched OFF.
...................................................................................................................................................................................................
12 With the new OMCP terminal window connection through SHMC selected, press F12
several times from the Local PC keyboard. This action will force the new JBXOMCP
board to boot from the existing JBXOMCP board and it must be done during the new
JBXOMCP board booting sequence.
Note: If this forced boot by pressing F12 does not work, you have to enter in the
BIOS settings of the new JBXOMCP board.
To enter in the BIOS settings, press ESC + F2 several times from the keyboard during
the new JBXOMCP booting sequence.
To force the new JBXOMCP board to boot from the existing JBXOMCP board:
From the BIOS Setup Utility window, use the arrow keys to navigate to the Boot
menu.
From Boot menu, use the arrow keys to select Hard Drive then press ! to disable
hard disk drive option.
Press F10 and then press Enter to save the changes you made and exit the BIOS.
When the new JBXOMCP board is starting to boot up from the existing JBXOMCP
board, the following message should appear:
CLIENT IP: 172.17.3.x MASK: 255.255.0.0 DHCP IP: 172.17.3.y
PXELINUX 2.05 2003-07-16 Copyright <C> 1994-2003 H. Peter Anvin
When the new JBXOMCP board is JBXOMCP1:
x is 160
y is 40.
When the new JBXOMCP board is JBXOMCP2:
x is 161
y is 30.
Hard disk Installation will take approximately 10 minutes.
...................................................................................................................................................................................................
13 In the terminal window connection through SHMC, the following messages should
appear:
Harddisk Installation Complete.
The Blade is going to reboot.
....................................................................................................................................................................................................................................
4-56 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXOMCP
Front RITs
....................................................................................................................................................................................................................................
Do not forget to disable the Network boot Option in the BIOS
settings if needed.
Type "go" and press "return" key to continue.
The Blade will reset after X seconds.
It shows this output seven times when X is 30, 25, 20, 15, 10, 5, 0 seconds.
Until X is 0 seconds, type go then press Enter to reboot the JBXOMCP board.
If X is 0 seconds, then the JBXOMCP board is automatically rebooting.
Note: The new JBXOMCP board is rebooting. If the boot sequence was modified,
remember to restore it.
To enter in the BIOS settings, press ESC + F2 several times from the keyboard during
the new JBXOMCP rebooting sequence.
To restore the boot sequence for the new JBXOMCP board:
From the BIOS Setup Utility window, navigate to Boot menu
From the Boot menu, select Hard Drive then press ! to enable hard disk drive
option
Press F10 and then press Enter to save the changes you made and exit the BIOS.
The new JBXOMCP board reboots from its disk. This sequence will take approximately
five minutes.
...................................................................................................................................................................................................
15 Enter the following command to synchronize the rpm files on the JBXOMCP boards:
/usr/local/bin/post-Replace-OMCP.sh
Status ------------------------ OK
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-57
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXOMCP
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
17 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that firmware
upgrade is necessary. Open a telnet session on the active OMCP and perform Step 1 to
Step 2.
The FIRMWARE-INCOMPATIBILITY alarm is raised, perform the corrective action
from [99,9] FIRMWARE-INCOMPATIBILITY
There is no firmware alarm after the blade is IT/FIT, it means the firmware level is up
to date.
...................................................................................................................................................................................................
18 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
Replace JBXCCP
Overview
This section is designed to show you how to:
Remove JBXCCP (p. 4-59)
Insert JBXCCP (p. 4-60)
....................................................................................................................................................................................................................................
4-58 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Remove JBXCCP
Front RITs
....................................................................................................................................................................................................................................
Remove JBXCCP
Remove JBXCCP
Note: This task is also performed during a 9130 BSC Evolution shelf reduction.
Remove a JBXCCP board:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
3 If the board to be replaced is the active one, from the BSC terminal or OMC-R, reset the
JBXCCP.
The board will become standby.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-59
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert JBXCCP
Front RITs
....................................................................................................................................................................................................................................
Insert JBXCCP
Insert JBXCCP
Note: This task is also performed during a 9130 BSC Evolution shelf extension.
Insert a JBXCCP board:
...................................................................................................................................................................................................
1 Ensure that the top and bottom ejector handles are in the outward position.
...................................................................................................................................................................................................
2 Insert the board into the shelf by placing the top and bottom edges of the board in the card
guides of the shelf. Ensure that the guiding module of shelf and board are aligned
properly.
...................................................................................................................................................................................................
3 Slide the board into the shelf until you feel resistance.
...................................................................................................................................................................................................
5 Simultaneously move the top and bottom ejector handles to the inward position to lock
the board to the shelf
...................................................................................................................................................................................................
6 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
10 The switched OFF blue LED indicates that the board is operational.
...................................................................................................................................................................................................
11 Connect the local terminal to the JAXSSW1 (port8) through an Ethernet cable.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-60 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert JBXCCP
Front RITs
....................................................................................................................................................................................................................................
telnet 172.17.33.1
...................................................................................................................................................................................................
14 Enter the following command for the newly replaced JBXCCP board to verify that the
onboard memory is bigger than 2 Mb:
/usr/local/bin/post-Replace-CCP.sh x
Where:
x is 50 for CCP1 (ATCA logical slot 5)
x is 60 for CCP2 (ATCA logical slot 6)
x is 70 for CCP3 (ATCA logical slot 7)
x is 80 for CCP4 (ATCA logical slot 8)
x is 90 for CCP5 (ATCA logical slot 9)
x is 100 for CCP6 (ATCA logical slot 10)
x is 120 for CCP7 (ATCA logical slot 12)
x is 140 for CCP8 (ATCA logical slot 14).
The following message appears in case that the onboard memory is bigger than 2 Mb:
Status ------------------------ OK
In case that the on board free memory is less than 2 Mb, the following error message
appears, preceded by an error code and by the value of the total current available board
memory:
Total memory is 1075768 less than 2000000, this board must be
replaced with a new one
Status ------------------------ NOK
Note: If the NOK message appears, the JBXCCP board have to be replaced with a
new one.
...................................................................................................................................................................................................
16 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-61
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert JBXCCP
Front RITs
....................................................................................................................................................................................................................................
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that the firmware
upgrade is necessary. Open a telnet session on the active OMCP and perform Steps 1
to 2 from CCP Firmware Upgrade from Upgrade CCP Firmware (p. 8-18) chapter.
The FIRMWARE-INCOMPATIBILITY alarm is raised, perform the corrective action
from [99,9] FIRMWARE-INCOMPATIBILITY
There is no firmware alarm after the blade is IT/FIT, it means the firmware level is up
to date.
...................................................................................................................................................................................................
17 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-62 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXSSW
Front RITs
....................................................................................................................................................................................................................................
Replace JBXSSW
Overview
The following figure shows the JBXSSW front view for different board variants.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-63
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXSSW
Front RITs
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-64 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXSSW
Front RITs
....................................................................................................................................................................................................................................
Remove JBXSSW
Remove a JBXSSW board:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-65
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXSSW
Front RITs
....................................................................................................................................................................................................................................
Insert JBXSSW
Insert a JBXSSW board:
...................................................................................................................................................................................................
1 Connect the Ethernet cable between LMT to the operational JAXSSW on port 8.
The IP address for LMT is 172.x.0.251 and subnet mask is 255.255.0.0
Where:
x is 17 if the replaced JBXSSW is JBXSSW2
x is 18 if the replaced JBXSSW is JBXSSW1.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-66 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXSSW
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Ensure that the top and bottom ejector handles are in the outward position.
...................................................................................................................................................................................................
8 Insert board into one of the hub slots of the shelf by placing the top and bottom edges of
the board in the card guides of the shelf. Ensure that the guiding module of shelf and
board are aligned properly.
...................................................................................................................................................................................................
9 Slide the board into the shelf until you feel resistance.
...................................................................................................................................................................................................
10 Simultaneously move the top and bottom ejector handles to the inward position to lock
the board to the shelf.
...................................................................................................................................................................................................
11 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
17 Enter the following command to perform an automatic VLAN configuration for the newly
installed JBXSSW board:
/usr/local/bin/post-Replace-FontSSW.sh x
Where xis :
1 if SSW1 was replaced
2 if SSW2 was replaced.
The following message appears in case of successful automatic VLAN configuration:
Status ------------------------ OK
The VLAN configuration is also displayed.
...................................................................................................................................................................................................
18 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that firmware
upgrade is necessary. Open a telnet session on the active OMCP and perform Step 5 to
Step 1 .
The the FIRMWARE-INCOMPATIBILITY alarm is raised, perform the corrective
action from [99,9] FIRMWARE-INCOMPATIBILITY
There is no firmware alarm after blade is IT/FIT, it means the firmware level is up to
date.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-68 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXSSW
Front RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
21 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-69
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Remove JBXFILL
Front RITs
....................................................................................................................................................................................................................................
Remove JBXFILL
Remove JBXFILL
Remove the ATCA front filler (JBXFILL):
...................................................................................................................................................................................................
2 Unfasten screws of front plate until board is detached from the shelf.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-70 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert JBXFILL
Front RITs
....................................................................................................................................................................................................................................
Insert JBXFILL
Insert JBXFILL
Insert the ATCA front filler (JBXFILL):
...................................................................................................................................................................................................
2 Slide the JBXFILL into the shelf until you feel resistance.
...................................................................................................................................................................................................
3 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-71
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Manage Rear RITs
Rear RITs
....................................................................................................................................................................................................................................
Rear RITs
Replace JAXPC
Overview
Note: The JAXPC used for replacement must be at level ICS 04 or higher.
The JAXPC stores ATCA Shelf remote inventory information therefore only one
JAXPC card replacement is allowed at the same time.
The two JAXPC boards slots, located on the right side of the JAXSMMs, are numbered
from 1 on the right to 2 on the left, on the back side of each side of the subrack chassis.
The following figure shows the front view for JAXPC board.
....................................................................................................................................................................................................................................
4-72 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXPC
Rear RITs
....................................................................................................................................................................................................................................
The following figure shows the location of the rotary switches on JAXPC board.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-73
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXPC
Rear RITs
....................................................................................................................................................................................................................................
Figure 4-17 JAXPC: Shelf Geographic Address Rotary Switches for Board Variant
Before 3BK 27226 AACA
....................................................................................................................................................................................................................................
4-74 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXPC
Rear RITs
....................................................................................................................................................................................................................................
Figure 4-18 JAXPC: Shelf Geographic Address Rotary Switches from Board Variant
3BK 27226 AACA On
Remove JAXPC
Perform the following tasks.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-75
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXPC
Rear RITs
....................................................................................................................................................................................................................................
For Board Variant Before 3BK 27226 AACA
Remove the JAXPC:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
5 Remove the board from the shelf using the ejector ring.
E...................................................................................................................................................................................................
N D O F S T E P S
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
3 Unfasten the screws of the front plate until the handle switch is detached from the front
plate of the board.
The handle switch activator releases the blinking of the blue LED. The blue H/S LED will
flash and then turn on steadily.
Wait until the blue LED is permanently lit.
....................................................................................................................................................................................................................................
4-76 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXPC
Rear RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Remove the board from the shelf using the ejector ring.
E...................................................................................................................................................................................................
N D O F S T E P S
Insert JAXPC
Perform the following tasks.
Set Rotary Switches
Insert the JAXPC:
...................................................................................................................................................................................................
1 Set the rotary switches according to your requirements (Figure 4-17, JAXPC: Shelf
Geographic Address Rotary Switches for Board Variant Before 3BK 27226 AACA
(p. 4-74)).
Select the following:
S1 (for board variants before 3BK 27226 AACA) or LS (from board variant 3BK
27226 AACA on):
Select the required option:
On the shelf 3 (bottom ATCA) set S1 to 3
On the shelf 4 (top ATCA) set S1 to 4.
S2 (for board variants before 3BK 27226 AACA) or MS (from board variant 3BK
27226 AACA on): always set to "0".
Note: Two JAXPC boards in the same shelf must always be set to the same SGA
(Shelf Geographic Address).
Two JAXPC in different shelves must always be set to different SGAs.
...................................................................................................................................................................................................
2 Back out the two screws until they engage the threads in the front panel.
This makes the insertion easier.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-77
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXPC
Rear RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 Insert board into the shelf by placing the top and bottom edges of the board in the card
guides of the shelf. Ensure that the guiding module of shelf and board are aligned
properly.
...................................................................................................................................................................................................
3 Wait until the blue H/S LED is lit. The red OOS LED is blinking.
...................................................................................................................................................................................................
5 Wait until the blue H/S LED is switched OFF. The switched OFF blue H/S LED indicates
that the board is running. The red OOS LED is blinking.
...................................................................................................................................................................................................
1 Insert board into the shelf by placing the top and bottom edges of the board in the card
guides of the shelf. Ensure that the guiding module of shelf and board are aligned
properly.
...................................................................................................................................................................................................
2 Slide the board into the shelf until you feel resistance.
...................................................................................................................................................................................................
3 Wait until the blue H/S LED is illuminated and the red OOS LED turns OFF.
...................................................................................................................................................................................................
4 Tighten the screws at the top and the bottom of the board.
In this way the ejector handle is closed and the board can be powered. The blue LED
blinks.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-78 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXPC
Rear RITs
....................................................................................................................................................................................................................................
The switched OFF blue H/S LED indicates that the board is activated.
E...................................................................................................................................................................................................
N D O F S T E P S
5 Enter the following command to perform an automatic post JAXPC board replace
procedure:
/usr/local/bin/post-Replace-PC.sh
Status ------------------------ OK
...................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-79
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXPC
Rear RITs
....................................................................................................................................................................................................................................
Check If Firmware Is Up to Date
...................................................................................................................................................................................................
1 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that firmware
upgrade is necessary. Perform Step 2 to Step 3 .
The FIRMWARE-INCOMPATIBILITY alarm is raised, perform the corrective action
from [99,9] FIRMWARE-INCOMPATIBILITY
There is no firmware alarm after blade is IT/FIT, it means firmware level is up to date.
...................................................................................................................................................................................................
3 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-80 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSSW
Rear RITs
....................................................................................................................................................................................................................................
Replace JAXSSW
Overview
The following table gives the JAXSSW port allocations.
Notes:
1. * Depends of the value of the VLAN_CONF _INDEX parameter. For more information
about flows and switch ports to be used, see Several Subnets for Separate O&M and
Telecom from the BSS Telecom Routing Configuration
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-81
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSSW
Rear RITs
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-82 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSSW
Rear RITs
....................................................................................................................................................................................................................................
Note: The shelf management controller in the shelf where the JAXSSW is to be
installed, treats the JBXSSW and the JAXSSW as one single unit. For this reason, it is
not possible to install the JAXSSW while the JBXSSW is powered ON. Instead, the
JAXSSW must be installed while the JBXSSW is powered OFF and then both the
JBXSSW and the JAXSSW have to be powered up together.
Remove JAXSSW
Remove a JAXSSW:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs, functions and alarms is available before starting the action.
...................................................................................................................................................................................................
3 Perform steps from Step 2 to Step 4 listed in Remove JBXSSW (p. 4-65) for the related
JBXSSW board. Do not unplug the corresponding JBXSSW.
...................................................................................................................................................................................................
4 Verify the cable labels and note the position for each cable.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-83
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSSW
Rear RITs
....................................................................................................................................................................................................................................
Insert JAXSSW
Insert a JAXSSW:
...................................................................................................................................................................................................
1 Locate the slot in the shelf's rear where the JAXSSW needs to be installed.
...................................................................................................................................................................................................
4 Ensure that the top and the bottom handles of the JAXSSW are in outward position.
...................................................................................................................................................................................................
5 Insert the JAXSSW into the shelf by placing the top and bottom edges in the rails of the
slot. When plugging the JAXSSW in or removing it, do not press on the front plate, but
use the handles.
...................................................................................................................................................................................................
7 Hook the lower and the upper handle into the shelf rail recesses.
...................................................................................................................................................................................................
8 Fully insert the JAXSSW and lock it to the shelf by pressing the two components of the
lower and the upper handles together and turning the handles towards the front plate.
During initialization, the blue hot swap LED switches OFF. Wait around 2 minutes until
the blue hot swap LED is switched ON again and only then continue with the next step.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-84 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSSW
Rear RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
12 Wait until the blue LEDs of both the JBXSSW and the JAXSSW are OFF.
A switched OFF blue LED indicates that the payload of the respective JBXSSW or
JAXSSW has been powered up and is operational.
...................................................................................................................................................................................................
13 Connect the Ethernet cable between LMT to the operational JAXSSW on port 8.
The IP address for LMT is 172.x.0.251 where:
x is 17 if the replaced JAXSSW is JAXSSW2
x is 18 if the replaced JAXSSW is JAXSSW1.
...................................................................................................................................................................................................
16 Enter the following command to perform an automatic VLAN configuration for the newly
installed JAXSSW board:
/usr/local/bin/post-Replace-RearSSW.sh x
where x is:
1 if SSW1 was replaced
2 if SSW2 was replaced.
The following message appears in case of successful automatic VLAN configuration:
Status ------------------------ OK
The VLAN configuration is also displayed.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-85
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSSW
Rear RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
19 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that firmware
upgrade is necessary. Open a telnet session on the active OMCP and perform Step 5 to
Step 1 from How to SSW Firmware Upgrade (p. 8-9).
Tthe FIRMWARE-INCOMPATIBILITY alarm is raised, perform the corrective action
from [99,9] FIRMWARE-INCOMPATIBILITY
There is no firmware alarm after the board is IT/FIT, the firmware level is up to date.
...................................................................................................................................................................................................
20 Check the status of the system. Check the status of the system. Ensure that the status for
all impacted SBLs, functions and alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-86 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSMM
Rear RITs
....................................................................................................................................................................................................................................
Replace JAXSMM
Overview
The following prerequisites must be available in order to perform the scenario:
Screwdriver
Wrist strap.
The two Shelf Manager Cards slots, located on the right side of the PEMs, are numbered
from 1 on the right to 2 on the left on the back side of each side of the subrack chassis.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-87
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSMM
Rear RITs
....................................................................................................................................................................................................................................
Remove JAXSMM
Remove a JAXSMM card:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
6 Unfasten screws of front plate until handle switch is detached from front plate of the
board.
...................................................................................................................................................................................................
Insert JAXSMM
Attention: When inserting the board, ensure that the handle switch is in the correct
position (see Figure Figure 4-21, JAXSMM - Handle Switch Positions (p. 4-89)).
....................................................................................................................................................................................................................................
4-88 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSMM
Rear RITs
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-89
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSMM
Rear RITs
....................................................................................................................................................................................................................................
Insert the JAXSMM:
...................................................................................................................................................................................................
1 Insert the board into the shelf by placing the top and bottom edges of the board in the card
guides of the shelf. Ensure that the guiding module of shelf and board are aligned
properly. The alignment protrusion facilitates the insertion and prevents bent pins.
...................................................................................................................................................................................................
2 Slide the board into the shelf until you feel resistance.
...................................................................................................................................................................................................
4 Tighten the screws at the top and the bottom of the board. In this way, the ejector handle
is closed and the board can be powered. The blue LED blinks twice, and then it stays lit.
...................................................................................................................................................................................................
7 Wait until the blue LED is switched OFF. The switched OFF blue LED indicates that the
board is operational.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-90 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXSMM
Rear RITs
....................................................................................................................................................................................................................................
Password:
alcatel
...................................................................................................................................................................................................
11 Enter the following command to perform an automatic post JAXSMM board replace
procedure:
/usr/local/bin/post-Replace-SMM.sh x
where x is:
1 for JAXSMM1
2 for JAXSMM2.
The following message appears in case of successful automatic post JAXSMM board
replace procedure:
Status ------------------------ OK
...................................................................................................................................................................................................
13 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that the firmware
upgrade is necessary. Perform Step 1 to Step 1 from How to Upgrade Shelf Manager
Firmware (p. 8-5).
The FIRMWARE-INCOMPATIBILITY alarm is raised, perform the corrective action
from [99,9] FIRMWARE-INCOMPATIBILITY
There is no firmware alarm after blade is IT/FIT, it means firmware level is up to date.
...................................................................................................................................................................................................
14 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-91
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXPS
Rear RITs
....................................................................................................................................................................................................................................
Replace JBXPS
Important information
DANGER
Electric-shock hazard
If any JBXPS for which alarms or other issues are reported has the power breaker in
OFF position, do not switch the power breaker to ON.
Replace the module following the appropriate method in order to avoid physical danger
and equipment danger.
....................................................................................................................................................................................................................................
4-92 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXPS
Rear RITs
....................................................................................................................................................................................................................................
Figure 4-22 Power Entry Module for Variants Before 3BK 27342 AACA
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-93
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXPS
Rear RITs
....................................................................................................................................................................................................................................
Figure 4-23 Power Entry Module from Variant 3BK 27342 AACA On
The Power Entry Modules are numbered from 1 on the left to 4 on the right of the rear
view of the subrack chassis.
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
....................................................................................................................................................................................................................................
4-94 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXPS
Rear RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 DANGER
Electric-shock hazard
If any JBXPS for which alarms or other issues are reported has the power breaker in
OFF position, do not switch the power breaker to ON.
Replace the module following the appropriate method in order to avoid physical danger
and equipment danger.
3 Switch OFF the breaker on the Power Distribution Unit (PDU) corresponding to the
JBXPS to be switched OFF.
The following table gives the breaker on the PDU corresponding to each JBXPS in
JSXATCA shelves.
...................................................................................................................................................................................................
5 DANGER
Risk of electrocution
To avoid short circuits and electric shock, the power lugs must not be energized before
removing the screws.
Using a multimeter, ensure that the power lugs are not energized before loosening the
screws.
Be careful when using tools in order to prevent a short circuit.
Remove the rubber protection on the power cables to access the studs.
...................................................................................................................................................................................................
6 Unfasten the power cables (POWER, then RETURN) from the JBXPS studs
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-95
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXPS
Rear RITs
....................................................................................................................................................................................................................................
Remove JBXPS
Remove the JBXPS:
...................................................................................................................................................................................................
2 On the JBXPS (realization variants before 3BK 27342 AACA), switch the H/S handle to
OPEN.
The blue H/S LED will blink (short intervals) and then remain steadily lit.
...................................................................................................................................................................................................
Insert JBXPS
Insert a JBXPS:
...................................................................................................................................................................................................
1 On the JBXPS (realization variants before 3BK 27342 AACA), ensure that H/S handle of
the new JBXPS is OPEN.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-96 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXPS
Rear RITs
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
5 On the JBXPS (realization variants before 3BK 27342 AACA), switch the H/S handle to
CLOSED.
The blue H/S LED will blink (long intervals) and then turn OFF.
...................................................................................................................................................................................................
1 Fasten the power cables (RETURN and POWER) to the JBXPS studs.
...................................................................................................................................................................................................
3 Turn ON the power distribution feeding the JBXPS with the breaker located on the PDU.
...................................................................................................................................................................................................
7 Using the BSC terminal, check if any alarm related to firmware is raised for the
replacement board.
If:
The FIRMWARE-NOT-UP-TO-DATE alarm is present, it means that firmware
upgrade is necessary:
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-97
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JBXPS
Rear RITs
....................................................................................................................................................................................................................................
To do so:
From a local terminal, open a telnet session on the active OMCP:
telnet 172.17.y.x
where:
y is 3 for ATCA shelf 3
y is 4 for ATCA shelf 4
x is 30 for JBXOMCP1 (ATCA physical slot 6)
x is 40 for JBXOMCP2( ATCA physical slot 9).
Type the username and the password:
root
alcatel
Perform Step 2 to Step 3 from Upgrade PEM Firmware (p. 8-24)
Close the telnet session on the JBXOMCP.
If the FIRMWARE-INCOMPATIBILITY alarm is raised, perform the corrective
action from [99,9] FIRMWARE-INCOMPATIBILITY
If there is no firmware alarm after blade is IT/FIT, it means firmware level is up to
date.
...................................................................................................................................................................................................
8 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-98 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace JAXFILL
Rear RITs
....................................................................................................................................................................................................................................
Replace JAXFILL
Overview
Unused slots, front and rear, must be equipped with fillers.
The JAXFILL are used to create the appropriate air flow within the subrack.
Remove JAXFILL
Remove an ATCA rear filler:
...................................................................................................................................................................................................
Insert JAXFILL
Insert an JAXFILL:
...................................................................................................................................................................................................
3 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-99
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-100 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Board Takeover
Replace Battery on JBXOMCP/JBXCCP
....................................................................................................................................................................................................................................
Board Takeover
Procedure
To perform a board takeover, only if the impacted board is the active one:
...................................................................................................................................................................................................
1 Start the 9130 BSC Evolution Terminal software. Refer to Start the Terminal Software
from the 9130 BSC Evolution Terminal User Guide.
...................................................................................................................................................................................................
3 After the takeover is done, check the ACT or USR2 LED status on the boards front panel.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-101
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Remove Board
Replace Battery on JBXOMCP/JBXCCP
....................................................................................................................................................................................................................................
Remove Board
Procedure
Remove a board:
...................................................................................................................................................................................................
4 Unfasten screws of front plate until the board is detached from the shelf.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-102 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Replace Battery
Replace Battery on JBXOMCP/JBXCCP
....................................................................................................................................................................................................................................
Replace Battery
Procedure
Replace the battery:
...................................................................................................................................................................................................
2 CAUTION
PCB and battery holder damage
Removing the battery with a screwdriver may damage the PCB or the battery holder.
To prevent this damage, do not use a screwdriver to remove the battery from its holder.
3 Locate the + sign on the new battery. It indicates the positive terminal of the battery.
...................................................................................................................................................................................................
4 Insert the battery into the blade's battery holder in such a way that the+ on top of the
battery is face up.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-103
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert Board
Replace Battery on JBXOMCP/JBXCCP
....................................................................................................................................................................................................................................
Insert Board
Procedure
Insert a board:
...................................................................................................................................................................................................
1 Ensure that the top and bottom ejector handles are in the outward position.
...................................................................................................................................................................................................
2 Insert board into the shelf by placing the top and bottom edges of the board in the card
guides of the shelf. Ensure that the guiding module of shelf and board are aligned
properly.
...................................................................................................................................................................................................
3 Slide the board into the shelf until you feel resistance.
...................................................................................................................................................................................................
5 Simultaneously move the top and bottom ejector handles to the inward position.
Result: The blue LED blinks.
After some seconds the blue LED is switched OFF.
...................................................................................................................................................................................................
7 Tighten the front plate screws which secure the board to the shelf.
...................................................................................................................................................................................................
10 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-104 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert Board
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 4-105
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain ATCA Subrack Insert Board
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-106 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
5 Maintain LIU Subrack
5
Overview
Purpose
This section describes how to replace the following LIU subrack RITs:
This section describes how to replace the following LIU subrack RITs:
JBXLIU boards
JBXMUX boards
JBXPEM modules
JBXDUM fillers.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-1
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Checks
Before You Start
....................................................................................................................................................................................................................................
Checks
Overview
Impact on System
As long as only one JBXPEM or JBXMUX is removed and replaced at any one time,
there is no impact on the system. This is because the RITs work in hot-standby mode. If a
RIT fails, the standby RIT takes over the tasks of faulty one. In case of failure, a
replacement must be organized as soon as possible to prevent traffic interruption.
When the LIU board is replaced there is a traffic outage. In case of failure, a replacement
must be organized as soon as possible to minimize traffic interruption.
The LIU subrack is equipped with:
Line Interface Unit boards (JBXLIU)
Power Entry Modules (JBXPEM)
Multiplexing boards (JBXMUX).
The following figure shows the front view of the LIU subrack.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-3
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack How to Replace LIU Board
Replace LIU Board
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-4 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack How to Replace LIU Board
Replace LIU Board
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-5
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack How to Replace LIU Board
Replace LIU Board
....................................................................................................................................................................................................................................
Important information
WARNING
Traffic reduction
When the LIU board is replaced there is a traffic reduction for about 4 minutes.
In the case of failure, a replacement must be organized as soon as possible to minimize
traffic interruption.
When replacing a LIU board, the replacement board must support the same impedance as
the replaced one.
....................................................................................................................................................................................................................................
5-6 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Remove LIU Board
Replace LIU Board
....................................................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
7 Remove the board from the shelf using the board handle.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-7
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Insert LIU Board
Replace LIU Board
....................................................................................................................................................................................................................................
1 Use the handle to insert the board into the shelf until you feel resistance.
...................................................................................................................................................................................................
6 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
Important information
Attention: In the LIU shelf, each slot unused by a board must be closed by a filler
front panel.
....................................................................................................................................................................................................................................
5-8 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack How to Replace JBXMUX Board
Replace JBXMUX Board
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-9
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack How to Replace JBXMUX Board
Replace JBXMUX Board
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-10 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Remove JBXMUX
Replace JBXMUX Board
....................................................................................................................................................................................................................................
Remove JBXMUX
Note: When removing the active board, reset the board before removing it either from
the BSC terminal or from the OMC-R.
Procedure
Remove the JBXMUX:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
7 Remove the board from the shelf using the board handle.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-11
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Insert JBXMUX
Replace JBXMUX Board
....................................................................................................................................................................................................................................
Insert JBXMUX
Procedure
Insert the JBXMUX:
...................................................................................................................................................................................................
1 Insert the board, using the handle, into the shelf until you feel resistance.
...................................................................................................................................................................................................
6 Using the BSC terminal check if the FIRMWARE-NOT-UP-TO-DATE alarm is raised for
the replacement board.
If this alarm is present, it means that a newer NE1oE firmware version is available.
To do so:
Also check that the FIRMWARE-NOT-UP-TO-DATE alarm is cleared.
It means that the firmware upgrade already started. As a confirmation, the
FIRMWARE-UPGRADE alarm is raised.
Wait for the firmware upgrade process to finish. It takes approximately 10 minutes.
The process is finished when the FIRMWARE-UPGRADE alarm is cleared.
Note: If the FIRMWARE-INCOMPATIBILITY alarm is raised, refer to [100,9]
FIRMWARE-INCOMPATIBILITY.
If the alarm is not present, continue with the next step.
....................................................................................................................................................................................................................................
5-12 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Insert JBXMUX
Replace JBXMUX Board
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-13
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack How to Replace JBXPEM
Replace JBXPEM
....................................................................................................................................................................................................................................
Replace JBXPEM
....................................................................................................................................................................................................................................
5-14 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Remove JBXPEM
Replace JBXPEM
....................................................................................................................................................................................................................................
Remove JBXPEM
Procedure
Remove JBXPEM:
...................................................................................................................................................................................................
1 Check and write down the status of the system. Ensure that the status for all degraded
SBLs and functions and all alarms is available before starting the action.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
7 If necessary, cut the cable ties used for power cable fixation.
Attention: Ensure that the power cable to be disconnected is the one attached to the
JBXPEM board to be replaced and for which the related power breaker on PDU was
switched OFF.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-15
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Remove JBXPEM
Replace JBXPEM
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
9 Remove the board from the shelf using the board handle.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
5-16 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Insert JBXPEM
Replace JBXPEM
....................................................................................................................................................................................................................................
Insert JBXPEM
Attention: Before inserting the new JBXPEM check the new board ICS.
Depending on new board ICS, apply the appropriate case:
Insert JBXPEM in Case of ICS 01 (p. 5-17)
Insert JBXPEM in Case of ICS 02 or Newer (p. 5-17).
2 Insert using handle the board with the power cable attached into the shelf until you feel
resistance.
...................................................................................................................................................................................................
7 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
1 Partially insert the board into slot rails, back connectors are not reached yet.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-17
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Insert JBXPEM
Replace JBXPEM
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Insert using handle the board with the power cable attached into the shelf until you feel
resistance.
...................................................................................................................................................................................................
8 Check the status of the system. Ensure that the status for all impacted SBLs and functions
and all alarms is cleared and no new alarms occurred.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
5-18 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Overview
Replace LIU Front Filler
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-19
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack How to Replace LIU Front Filler
Replace LIU Front Filler
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-20 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Remove JBXDUM
Replace LIU Front Filler
....................................................................................................................................................................................................................................
Remove JBXDUM
Procedure
Remove the JBXDUM filler:
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 5-21
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Maintain LIU Subrack Replace JBXDUM
Replace LIU Front Filler
....................................................................................................................................................................................................................................
Replace JBXDUM
Procedure
Replace JBXDUM filler:
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-22 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
6 9130 BSC Evolution Cables
6
Overview
Purpose
This section lists all cables used in the BSC. It includes cable lists and connector position
schematics for:
This section lists all cables used in the BSC. It includes cable lists and connector position
schematics for:
Telecommunications Subrack
Control Station Server.
Contents
Intervention Levels
Overview
The following figure shows the 9130 BSC Evolution rack intervention levels.
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 6-1
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
9130 BSC Evolution Cables Intervention Levels
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-2 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
9130 BSC Evolution Cables Intervention Levels
....................................................................................................................................................................................................................................
There are some cables with the ends marked with labels accordingly to the place where
this end should be placed. Consequently, pay attention to this labels when connect the
cables.
For example, for cables interconnecting 2 different subracks, each end (may have) a label
on which is written:
Subrack's corresponding intervention level, or/and
Board's slot number, or/and
Board's connector related information.
The following figure gives the intervention level for the front RITs.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 6-3
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
9130 BSC Evolution Cables Intervention Levels
....................................................................................................................................................................................................................................
The following figure gives the intervention level for the rear RITs.
....................................................................................................................................................................................................................................
6-4 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
9130 BSC Evolution Cables Intervention Levels
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 6-5
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
9130 BSC Evolution Cables Intervention Levels
....................................................................................................................................................................................................................................
There are some cables with the ends marked with labels accordingly to the place where
this end should be placed. Consequently, pay attention to this labels when connect the
cables.
The following table gives the boards position in the ATCA shelf and part numbers.
....................................................................................................................................................................................................................................
6-6 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
9130 BSC Evolution Cables LIU Subrack Cables
....................................................................................................................................................................................................................................
Table 6-3 Cable List for GE Links between LIU and ATCA
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 6-7
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
9130 BSC Evolution Cables LIU Subrack Cables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-8 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
7 Software Procedures
7
Overview
Purpose
This section describes how to:
Modify Community String Name
Software and Hardware Diagnosis
Modify BSC IP Subnetwork Address
Tool collecting on-demand traces/logs
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-1
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-2 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures How to Modify Community String Name
Modify Community String Name
....................................................................................................................................................................................................................................
3 In the terminal window 172.17.y.x corresponding to the active OMCP, type the following
command:
cd /usr/local/bin/
./mpRumSetSnmpPasswd <OLD SNMP PASSWD> <NEW SNMP PASSWD 1> <NEW
SNMP PASSWD 2>
This command modifies the community string name in the snmpd.local.conf
configuration file.
The <OLD SNMP PASSWD> must be known.
The <NEW SNMP PASSWD 1> must be egual to <NEW SNMP PASSWD 2>.
Note: The SNMP Password is also known as the Community String.
The Community String must be the same as the one defined at OMCR side.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-3
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures How to Modify Community String Name
Modify Community String Name
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-4 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures How to Perform a Software and Hardware Diagnosis
Perform a Software and Hardware Diagnosis
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-5
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures How to Reset BSC
....................................................................................................................................................................................................................................
Reset BSC
....................................................................................................................................................................................................................................
7-6 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures how to Modify BSC IP External Configuration
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-7
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures how to Modify BSC IP External Configuration
Modify BSC IP External Configuration
....................................................................................................................................................................................................................................
Result: The Modify IP Parameters window opens.
...................................................................................................................................................................................................
5 Click on the IP Parameters tab and complete the following fields as required:
....................................................................................................................................................................................................................................
7-8 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures how to Modify BSC IP External Configuration
Modify BSC IP External Configuration
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-9
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures how to Modify BSC IP External Configuration
Modify BSC IP External Configuration
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-10 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures how to Modify BSC IP External Configuration
Modify BSC IP External Configuration
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-11
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures General Information
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
General Information
IP Assignment Rules in 9130 BSC Evolution with Two LAN Solution
....................................................................................................................................................................................................................................
7-12 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures General Information
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
In the two LAN configuration, SubnetB +5 and SubnetC +5 are used as external router
address.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-13
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures General Information
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
Table 7-4 IP Assignment in 9130 BSC Evolution External Subnet A (continued)
Note: The recommended connection for the External Alarm Box is direct to the edge
Switch / Router.
....................................................................................................................................................................................................................................
7-14 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Modify BSC IP Subnetwork Address
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
6 Click on OK.
The Modify IP Parameters window opens.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-15
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Modify BSC IP Subnetwork Address
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
In the:
Ext Router Subnet B:, type the new IP address for External Router interface
connected to Subnet B
Ext Router Subnet C:, type the new IP address for External Router interface
connected to Subnet C
Subnet-B-Start-IP-Address, type the new start IP address of the BSC subnet B
Subnet-C-Start-IP-Address, type the new start IP address of the BSC subnet C
Subnet B&C Mask, type the new mask value for subnet B and C addresses of the BSC.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-16 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Modify BSC IP Configuration from 1 LAN to 2 LANs
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
1 Open the BSC terminal from the Windows desktop. Click on Start -> Programs ->
WinBSC -> 9130 BSC -> B12 -> Windows 9130 BSC Terminal B12.
...................................................................................................................................................................................................
3 To switch to master user mode, from the BSC Terminal menu bar, select Utilities-
>Switch User Mode or press F6.
...................................................................................................................................................................................................
7 Click on OK.
The Modify IP Parameters window opens.
...................................................................................................................................................................................................
8 Select the Static Route Address tab, and in the Static Route Table, fill with the 0.0.0.0
address default values.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-17
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Modify BSC IP Configuration from 1 LAN to 2 LANs
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
10 In the O&M Reachability Test IP Address field, fill with the IP default 0.0.0.0 address
value.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-18 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Modify BSC IP Configuration from Two LANs to One LAN
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
1 Open the BSC terminal from the Windows desktop. Click on Start -> Programs ->
WinBSC -> 9130 BSC -> B12 ->Windows 9130 BSC Terminal B12.
...................................................................................................................................................................................................
3 To switch to master user mode, from the BSC Terminal menu bar, select Utilities-
>Switch User Mode or press F6.
...................................................................................................................................................................................................
7 Click on OK.
Result: The Modify IP Parameters window opens.
...................................................................................................................................................................................................
8 Select the IP Parameters tab and complete the following fields accordingly:
BSC Start O&M IP Address
BSC O&M IP Subnet Mask
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-19
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Modify BSC IP Configuration from Two LANs to One LAN
Modify 9130 BSC Evolution IP Configuration
....................................................................................................................................................................................................................................
In the IP Ethernet Protocol field select 'E_1 LAN'
O&M Reachability Test IP Address
...................................................................................................................................................................................................
9 In selected IP Parameters tab set to the value 0.0.0.0 the following fields:
Ext Router Subnet B
Ext Router Subnet C
Subnet-B-Start- IP-Address
Subnet-C-Start- IP-Address
BSC O&M IP Subnet Mask
...................................................................................................................................................................................................
10 Select the Static Route Address tab and add the static route for OMC connection.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-20 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Overview
Tool Collecting On-Demand Traces/Logs
....................................................................................................................................................................................................................................
Description
Overview
The script is under /common/bsc/SCPRDISK/, named TCKN????.??? (the ????.??? is
according to the package release). Only the script on the active OMCP can be launched.
The OAM and Telecom traces are collected into the /var/log/secured/ directory on both
OMCP boards.
The trace data includes:
Realtime Trace
MXPF Trace/logs
DLS
Core files
BSC Version
MXPF Version
Patch Names
The folder structure in trace secure is as follows:
Save BSC, MXPF version and patch names: /var/log/secured/BSC-General.txt
Save the total data size in a secure folder: /var/log/secured/secure-size.txt
Save DLS file: /var/log/secured/DLS/
Save core files: /var/log/secured/core
Save mxpf common trace files: /var/log/secured/mxpf/common
Save mxpf common trace files that have not been merged yet: /var/log/secured/mxpf/
common/nomerged/
Save mxpf log files: /var/log/secured/mxpf/logs
Save mxpf log files that have not been merged yet: /var/log/secured/mxpf/logs/
nomerged
Save mxpf srp files: /var/log/secured/mxpf/srp
Save mxpf srp files that have not been merged yet: /var/log/secured/mxpf/srp/
nomerged
Save real time trace files: /var/log/secured/realtime/
Save real time trace files that have not been merged yet: /var/log/secured/realtime/
nomerged/
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-21
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Description
Tool Collecting On-Demand Traces/Logs
....................................................................................................................................................................................................................................
The script can be launched in two modes:
Emergency Mode (p. 7-22) to collect Telcom traces
Normal Mode (p. 7-24) to collect corresponding O&M traces.
Emergency Mode
Overview
The script prompts a message for the operator to make a selection:
Tool for Trace Collection, please choose:
e for emergency Trace Collection => TEL/DLS/BSC General Info.
n for normal Trace Collection => OAM/CORE/DLS/BSC General Info.
q for Quit.
1.[e/n/q]
To continue to emergency mode trace collection, select:
e
The script prompts:
2.Do you want to collect Telecom trace? [y/n]
y
3.Enter the telecom problem type [CS|PS|ATRUNK]:
Enter CS, PS or ATRUNK, according to the related problem.
4.Please enter the duration time in seconds of telecom trace
collection [120]:
Enter the required duration.
For CS/PS problems, two cell-ids are requested:
5.Enter the first LAC,CI .e.g. 1,2:
6.Enter the second LAC,CI e.g. 1,2:
For Atrunk problem, two Atrunk numbers are requested:
5.Enter the first Atrunk Number e.g. 1:
6.Enter the second Atrunk Number e.g. 1:
The script waits according to the duration set in Step 4 for the trace collection to end.
Wait 120 seconds for creating telecom trace. Press B, if you
want to stop creating.
....................................................................................................................................................................................................................................
7-22 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Emergency Mode
Tool Collecting On-Demand Traces/Logs
....................................................................................................................................................................................................................................
............
Wait 60 seconds for Trace Collection. ............
Start time and end time are displayed:
Start time: yyyymmdd hhmmss
End time: yyyymmdd hhmmss
Confirm backup Telecom traces:
7.Do you confirm to backup Telecom trace? [y/n]
y
If older traces are already present in /var/log/secured, the script prompts:
8.You already have trace saved under, please
y: I have transferred previous trace to OMC, I want delete and
continue.
n: I want quit and transfer previous trace firstly.
[y/n]
y
Delete previous trace now!
Backup realtime trace for telecom!
To end the Telecom trace collection when prompted:
9.Do you want any more Telecom trace?[y/n]
Select:
n
The script ends with the following output:
Backup DLS now!
You can recover BSC now.
Complete!
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-23
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Normal Mode
Tool Collecting On-Demand Traces/Logs
....................................................................................................................................................................................................................................
Normal Mode
Overview
If older traces are already present in /var/log/secured, the script prompts:
1.If it has trace saved under /var/log/secured, please
y: I have transferred previous trace to OMC, I want delete and
continue.
n: I want quit and transfer previous trace firstly.
[y/n]
y
Delete previous trace now!
The script prompts a message for the operator to make a selection:
Tool for Trace Collection, please choose:
e for emergency Trace Collection => TEL/DLS/BSC General Info.
n for normal Trace Collection => OAM/CORE/DLS/BSC General Info.
q for Quit.
2.[e/n/q]
To continue to normal mode trace collection, select:
n
The script prompts the user to insert the start and end time of trace collection:
Please Input Trace [StartTime, EndTime], in BSC Time.
Current BSC Time: <date> <time>
3.Input StartTime [YYYYMMDDHHMM], e.g. 200901012300
<yyyymmddhhmm>
YEAR=yyyy MONTH=mm DAY=dd HOUR=hh MINUTE=mm
4.Input EndTime [YYYYMMDDHHMM], e.g. 200901012359
<yyyymmddhhmm>
YEAR=yyyy MONTH=mm DAY=dd HOUR=hh MINUTE=mm
Waiting for Trace Collection.
............
Backup OAM trace!
- Backup realtime trace!
- Backup MXPF trace!
....................................................................................................................................................................................................................................
7-24 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures Normal Mode
Tool Collecting On-Demand Traces/Logs
....................................................................................................................................................................................................................................
- Backup all the TPDUMP and TpConf files
- Backup core files
- Backup linux general info!
Backup DLS now!
Receive command BACKUP from current OMCP. Now SSH to another
OMCP to backup trace!
Backup OAM trace!
- Backup realtime trace!
- Backup MXPF trace!
- Backup all the TPDUMP and TpConf files
- Backup core files
- Backup linux general info!
Backup DLS now!
Connection to <IP address of active OMCP board> closed.
Complete!
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-25
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures File Transfer to 9153 OMC-R
Tool Collecting On-Demand Traces/Logs
....................................................................................................................................................................................................................................
7 To transfer specified files, drag the files from the OMCP board side and drop them on the
OMC-R side.
...................................................................................................................................................................................................
8 From the toolbar, click on to disconnect from the first OMCP board.
E...................................................................................................................................................................................................
N D O F S T E P S
7 To transfer specified files, drag the files from the OMCP board side and drop them on the
OMC-R side.
...................................................................................................................................................................................................
8 From the toolbar, click on to disconnect from the second OMCP board.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 7-27
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Software Procedures File Transfer to 9153 OMC-R
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-28 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
8 Upgrade Firmware
8
Overview
Purpose
This section describes all the necessary operations for remote, online and from the BSC
terminal to perform firmware upgrades for the 9130 BSC Evolution.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-1
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-2 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Description
How to Upgrade Firmware and Payloads
....................................................................................................................................................................................................................................
Description
Overview
Use this scenario to upgrade to different firmware and payloads for a 9130 BSC
Evolution.
Firmware upgrade procedure is simple and easy, is triggered by operator upon reception
of alarms "FIRMWARE-NOT-UP-TO-DATE". This is possible because the firmware
packages are part of the BSS package.
Note: The Power Entry Module (PEM) defines the SBL mapped on the JBXPS
module from the ATCA shelf.
The following table lists the types of boards and the firmware to be upgraded.
There are two methods to upgrade the firmware for the BSC boards listed above:
From the BSC Terminal; for more information, see Check / Upgrade Firmware from
the 9130 BSC Evolution Terminal User Guide.
From the OMC-R / PC NEM
Firmware upgrade action is executed manually by the operator, one by one, and more
than one upgrade action in parallel is forbidden.
The standby board is upgraded first, followed by the active one. Firmware upgrades
are performed only when the BSC is stable (under IT).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-3
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Description
How to Upgrade Firmware and Payloads
....................................................................................................................................................................................................................................
FAN, PEM and PC are exceptions, and can be upgraded in one of the following ways:
Individually, board by board
All PEM or all FAN or all PC
All PEM and all FAN and all PC.
If the following actions are ongoing, firmware upgrades are forbidden:
SWR is ongoing
Other board is under firmware upgrade; this also includes the TP/NE1OE
firmware upgrade
BSC reset is ongoing
IPMB has some problems (FATAL-HW-FAILURE alarm is reported on the
OMC/BSC terminal).
Attention: Shelf manager (SMM) must be the first boards to be upgraded, followed
by (SSW), and then automatically by the MUX boards. When the SMM, SSW, and
MUX are upgraded, the firmware upgrade for the remaining boards (TP, OMCP, CCP,
PEM, FAN, PC) can be performed.
....................................................................................................................................................................................................................................
8-4 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade Shelf Manager Firmware
Upgrade Shelf Manager Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-5
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade Shelf Manager Firmware
Upgrade Shelf Manager Firmware
....................................................................................................................................................................................................................................
Where:
y is 3 for ATCA shelf 3
y is 4 for ATCA shelf 4
...................................................................................................................................................................................................
5 Disconnect from the SHMC and connect on the active OMCP with the root account:
exit
su
<root password>
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
8-6 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade Shelf Manager Firmware
Upgrade Shelf Manager Firmware
....................................................................................................................................................................................................................................
Upgrade Shelf Manager
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-7
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade Shelf Manager Firmware
Upgrade Shelf Manager Firmware
....................................................................................................................................................................................................................................
Use one of the following methods:
From the active OMCP:
cd /usr/local/fw_upgrade/script/
./mx_shelfmanagerTakeOver.sh
From the OMC-R/BSC terminal, reset the active shelf manager.
...................................................................................................................................................................................................
3 Wait until the takeover action is finished and perform Step 2 to Step 1 for the new
standby board.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
8-8 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to SSW Firmware Upgrade
SSW Firmware Upgrade
....................................................................................................................................................................................................................................
2 Check remote connection to determinate which SSW is active from O&M point of view,
which SSW is carrying MXBSC O&M IP address:
ifconfig
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-9
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to SSW Firmware Upgrade
SSW Firmware Upgrade
....................................................................................................................................................................................................................................
A list of IP addresses is displayed:
If the active OMCP virtual IP address 172.16.33.1 is linked with eth0:5, it means
remote SSW1 is active from O&M point of view
If the active OMCP virtual IP address 172.16.33.1 is linked with eth1:5, it means
remote SSW2 is active from O&M point of view.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-10 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to SSW Firmware Upgrade
SSW Firmware Upgrade
....................................................................................................................................................................................................................................
whole firmware upgrade success!
The firmware upgrade failed if the following message is displayed:
whole firmware upgrade fail!
In the second case, the system prints the error description on the screen. Please follow
the instructions.
Note: If the firmware upgrade also fails after this workaround, contact Alcatel-Lucent
team support.
If the firmware upgrade process was launched, the target board will automatically reset
after the firmware upgrade finishes, regardless of success or failure.
Wait approximately five minutes until it becomes IT/FIT.
E...................................................................................................................................................................................................
N D O F S T E P S
3 Wait until the takeover action is finished and perform Step 5 to Step 1 for the new
standby board.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-11
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade MUX and TP Firmware
Upgrade MUX and TP Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-12 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade MUX Firmware
Upgrade MUX and TP Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-13
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade TP Firmware
Upgrade TP Firmware
....................................................................................................................................................................................................................................
Upgrade TP Firmware
1 If the FIRMWARE-NOT-UP-TO-DATE/IPMI-FW-NOT-UP-TO-DATE/TPIP-FW-NOT-
UP-TO-DATE alarm is displayed for the standby TP board, reset it.
The FIRMWARE-NOT-UP-TO-DATE/IPMI-FW-NOT-UP-TO-DATE/TPIP-FW-NOT-
UP-TO-DATE alarm is cleared for the board under reset.
The FIRMWARE-UPGRADE alarm is raised to confirm the firmware upgrade process.
Wait for the firmware upgrade process to finish. If the firmware version for NE1oE, IPMI
and TPIP need to be upgraded, the process can take up to 35 minutes.
The FIRMWARE-UPGRADE alarm is cleared when the process is finished.
...................................................................................................................................................................................................
2 If the FIRMWARE-NOT-UP-TO-DATE/IPMI-FW-NOT-UP-TO-DATE/TPIP-FW-NOT-
UP-TO-DATE alarm is displayed for the active TP board, reset it only if the standby TP
board is in traffic.
The FIRMWARE-NOT-UP-TO-DATE/IPMI-FW-NOT-UP-TO-DATE/TPIP-FW-NOT-
UP-TO-DATE alarm is cleared for the board under reset.
The FIRMWARE-UPGRADE alarm is raised to confirm the firmware upgrade process.
Wait for the firmware upgrade process to finish. If the firmware version for NE1oE, IPMI
and TPIP need to be upgraded, the process can take up to 35 minutes.
The FIRMWARE-UPGRADE alarm is cleared when the process is finished.
...................................................................................................................................................................................................
3 If the Firmware upgrade was not perform successfully, follow the steps below:
Check FW Upgrade Info in the Alcatel-Lucent 9130 BSC Evolution - NEM User
Guide to view the latest firmware upgrade log
Perform the necessary tasks indcated in the View Firmware Upgrade Log window.
....................................................................................................................................................................................................................................
8-14 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade TP Firmware
Upgrade TP Firmware
....................................................................................................................................................................................................................................
Note: If the firmware upgrade also fails after this workaround, contact the
Alcatel-Lucent support team.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-15
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade OMCP Firmware
Upgrade OMCP Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-16 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade OMCP Firmware
Upgrade OMCP Firmware
....................................................................................................................................................................................................................................
OMCP Firmware Upgrade
...................................................................................................................................................................................................
4 Wait until the takeover action is finished and perform Step 1 to Step 2 for the new
standby board.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-17
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade CCP Firmware
....................................................................................................................................................................................................................................
1 From the BSC terminal or OMC-R, check the CCP status (active/standby).
...................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
8-18 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade CCP Firmware
Upgrade CCP Firmware
....................................................................................................................................................................................................................................
Where y is the physical slot number:
5 if standby CCP is CCP5
10 if standby CCP is CCP10
4 if standby CCP is CCP4
11 if standby CCP is CCP11
3 if standby CCP is CCP3
12 if standby CCP is CCP12
13 if standby CCP is CCP13
14 if standby CCP is CCP14
The firmware upgrade script finishes with following contents:
Firmware upgrade is successful if:
whole firmware upgrade success!
Firmware upgrade failed if:
whole firmware upgrade fail!
In this case, the system prints the error descriptions on the screen. Correct errors
accordingly.
Note: If the firmware upgrade also fails after this workaround, contact Alcatel-Lucent
team support.
If the firmware upgrade process was launched, the target board will automatically reset
after the firmware upgrade finishes, regardless of success or failure.
Wait approximately five minutes until it becomes IT/FIT.
...................................................................................................................................................................................................
3 Upgrade the firmware for the next CCP. Perform a CCP takeover.
Use one of the following methods:
From the OMC-R, reset the active CCP
From the BSC terminal, reset the active CCP.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-19
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade CCP Firmware
Upgrade CCP Firmware
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Wait until the takeover action is finished and perform Step 1 to Step 2 for the new
standby board.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
8-20 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware How to Upgrade PEM, FAN, PC Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-21
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade PEM, FAN and PC Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-22 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade PEM, FAN and PC Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-23
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade PEM Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-24 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade PEM Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
The firmware upgrade script finishes with following contents:
Firmware upgrade is successful if:
whole firmware upgrade success!
Firmware upgrade failed if:
whole firmware upgrade fail!
In this case, the system prints the error descriptions on the screen. Correct the errors
accordingly.
Note: If the firmware upgrade also fails after this workaround, contact Alcatel-Lucent
team support.
If the firmware upgrade process was launched, the target board will reset automatically
after the firmware upgrade finishes, regardless of success or failure.
Wait approximately five minutes until it becomes IT/FIT.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-25
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade FAN Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-26 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade FAN Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
The firmware upgrade script finishes with following contents:
Firmware upgrade is successful if:
whole firmware upgrade success!
Firmware upgrade failed if:
whole firmware upgrade fail!
In this case, the system prints the error descriptions on the screen. Correct the errors
accordingly.
Note: If the firmware upgrade also fails after this workaround, contact Alcatel-Lucent
team support.
If the firmware upgrade process was launched, the target board will automatically reset
after the firmware upgrade finishes, regardless of success or failure.
Wait approximately one minute until it becomes IT/FIT.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-27
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade PC(A100) Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-28 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade PC(A100) Firmware
Upgrade PEM, FAN, PC Firmware
....................................................................................................................................................................................................................................
whole firmware upgrade fail!
In this case, the system prints the error descriptions on the screen. Correct the errors
accordingly.
Note: If the firmware upgrade also fails after this workaround, contact Alcatel-Lucent
team support.
If the firmware upgrade process was launched, the target board will automatically reset
after the firmware upgrade finishes, regardless of success or failure.
Wait approximately five minutes until it becomes IT/FIT.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9130 BSC 8-29
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012
Upgrade Firmware Upgrade PC(A100) Firmware
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-30 Alcatel-Lucent 9130 BSC
9YZ-03803-1240-PCZZA B12
Issue 5 July 2012