You are on page 1of 1

12 O @ 200 C/C BENTUP

0.48 BAR
0.15 15 O @ 200 C/C
0.21 DISTRIBUTION BAR
SKYLIGHT
0.40 0.16
1.12

0.16

DETAIL AT D SCALE 1:10 0.43


A A' 3Mx3M
RCC FOOTING 0.69

EDGE BEAM
SKYLIGHT 0.63

C 0.6X0.6 COLUMN

PLANSCALE 1:100 FULCRUM/DIAPHRAGM RCC GUTTER


BEAM
1.11

1.18 FULCRUM / DIAPHRAGM


BEAM 1.8M DEPTH
1.82 0.18
5.40
2.70

44.84 RCC GUTTER


A SECTION AA' SCALE 1:100 0.50
0.86 12MM STIRRUPS 200C/C

D 50MM SCREED
100MM BRICK BAT COBA
B

NTS 1.28

DETAIL AT C SCALE 1:10


RCC FOLDED PLATE
0.15 20 O @ 150 C/C MAIN BAR
12 O @ 200 C/C BENTUP BAR
0.21
15 O @ 200 C/C DISTRIBUTION BAR

15 O @ 200 C/C DISTRIB. BAR


20 O @ 150 C/C MAIN BAR
DETAIL AT A SCALE 1:20 0.076 50MM SCREED

ALTERNATIVE COS45 = R1 / L1 THICKNESS = T


100MM BRICK BAT COBA
R = SPAN MINIMUM THICKNESS SHOULD BE
CALCULATION L1
40 1 / 2 = 0.375 / L1 T = 0.530 / 15 T = 0.075M
R 45 R = 15/40 L1 = 0.375 / L1 T = 0.035 2T = 0.150M 12O @ 200MM C/C
L1 = 0.530M
R = 0.375M
0.15 MAIN BARS TO HANDLE
MORE TENSILE STRENGTH

DETAIL AT B SCALE 1:20

ROYAL JADHAV SIGN DATE

FOLDED PLATE 13ARC11

AIKTC SOA
6-9-2017