IES COLLEGE OF ARCHITECTURE

Sem 9 Architectural Design

Programmatic Space Requirement June 16, 2017

The Indian Information Technology (IT) industry has been one of the drivers of skill-oriented employment in
the country for several decades now. While most IT firms have been doing work that is supportive in nature
to the core innovation that has been taking place in the West, recent upheavals due to US laws are making
India IT firms feel the need to begin innovative programming.

Programmers are software engineers who engage in translating an idea into a workable interface on our
communication devices, be they cell phones or computers. However, the idea that needs to be translated
is, perhaps, the most important since it needs to be saleable to generate income for the company.

Simultaneously, a companys profits also come from programming other companies ideas into workable
interfaces for the device users. Hence, the support role as well as the creative ideation are important for
the survival of a software company.

The present project aims to provide infrastructure for one such software company (you may assume the
name of the companywhether existing or fictitious) in India. The creative and the programming areas are
the primary departments. All other departments are support departments.

Hence, for the sake of our studio project the structure of the company beginning from the locally stationed
executive would be as follows:

EXECUTIVE

1) Programming
2) Administration
3) Accounts
4) Sales

The following are the spaces that you need to provide in your design: 900 SM Approx.

1) EXECUTIVE OFFICES M2
a) Presidents room with attached toilet and Anteroom - 50
b) Directors (5 cabins with attached toilets) - 30 each
c) Each of the above to have at least one secretary - 10 each
d) Visitors area with toilet - 200 nos.
e) Entrance & Reception - 500
f) Conference room for 15 people - 100
g) Staff toilets ( as needed)
h) Store room - 50
i) Pantry - 10
Page 1 of 4
2) PROGRAMMING 12940 sm Approx.+Amenities
a) 10 Heads rooms with toilets 15sm (150 sm)
b) 2 Manager for each head with toilets 12sm/mgr (240 sm)
c) Work stations (72 nosX20 NOS) 200X20NOS=4000

d) Informal open discussion areas (for 2-4 people-10 NOS / mgr team)7-10 =100x20=2000
e) Formal meeting room (3 nos. 10-15 people/mgr team) 30(90x20=1800)
20/inch/PERSON.
f) Seminar Hall (50 people) X 1.5x1/mgr team 75(1500)
g) Auditorium (150 people) X 1.5x1/heads team 300x10(3000)
h) Amenities (Outdoor and Indoor, per your choice)
i) Toilets as needed
j) IT maintenance room with 20 work desks +1 heads cabinX10/per person 250

3) ADMINSTRATION 4600sm Approx.


a) Catering 2900
-Main kitchen 300
-Stores with loading/unloading bays 100
-Cafes spread across the campus 100x10
- Dining halls (5 nos 250 capacity each; with serving counter, pantry) 300x5=1500
-Toilets as needed

b) Facilities Management = 1500 sm approx.

-Amenities management office with workstations and stores (Toilets as needed)


-Services Maintenance office (including BMS) with stores (Toilets as needed)
-Housekeeping offices with stores, supply and disposal areas (Toilets as needed)
-Security Management including frisking, store, changing room, toilets, rest area, etc.

c) Transportation
-Head )
-2 Assistants )
-4 Secretarial staff } 200sm Approx.
-Toilets for above )
-Store areas for maintenance equipment )
-Drivers rest areas with toilets and lockers )

4) SALES 1000 sm Approx.


a) Head )
b) Assistants to the Head4 }

Page 2 of 4
c) Market surveyors 25 )
d) Small meeting areas (4-5 people) )x4=50
e) Large meeting areas (6-15) -x2=60
f) Seminar Hall -500
g) Toilets as needed

5) ACCOUNTS 500 sm Approx.


-Chief Accountant )
- Assistant accountants3 )
-Clerks } 500
-Store room )
-Toilets as needed )

6) ENTRANCE- 2000 sm Approx.

-Entrance space/s with inquiry, security check , registration for visitors, waiting lounge, toilets, store area,
front office, tea/coffee vending machines and/or pantry, enclosed cabins for discussions.

7) SERVER ROOM

Central server room 2000 sm Approx.

All Services infrastructure to be provided as per requirements.

All parking to be provided as per requirements. Parking maybe taken in basements and/or on stilts
and/or in a separate block per your design concept.

Page 3 of 4
Date: 13th May 2017.

DCR NAVI MUMBAI

15411 X 1.25 ( FSI ) = 19,263.75 m2


Fungible 1.20 = 23,116.50 m2
10m2 / person = 2,312 Nos.
Height = 50.30 M.
MSL = 5.0 M
Floors = 250 / per / floors. Approx

Services :
1) Nos of Staircase - 2 nos (Enclosed Type) 2 m wide, Travel distance Commercial
bldg. - 22.5 m to 30 m.
2) Elevators - 4 nos + Service Elevator.
3) Toilet Blocks as per DCR
4) Drainage / Plumbing / O.H & U/G Tank.( Fire requirement 3 lakh u/g, 30K o/h)
5) Air Conditioning / AHU.
6) Sever Room.
7) Electrification / Sub Station.
8) STP (Sewerage Treatment).
9) RWH (Rain Water Harvesting)
10) Parking (Basement 2/3 levels)
11) Service Ducts ( Elec/ Tele/CCTV/Fire hose, wet riser)

Sanitation Requirement
Male Female
W.C. 1 per 25 1 per 15
Urinals 4 for 71 100 -
Add 3% 101 to 200 -
2.5% Over 200. -
Wash Basin 1 per 25 nos. 1 per 25 nos.
Drinking Water 1 per 100 1 per 100

Refuge Area - At 24 m 15 m2 Or 0.3 m2 / person for 2 floors above 24m.


- At 39m level.
- Above 39m every 15m.
- Refuge Area at middling level.
- Every alternate floor above 24m.

Page 4 of 4