2. PROJECT LOCATION When suitable sites for housing & Same as PD 957
outside potential hazard prone &
protection areas
3. LAND LOCATION
(Percentage of Gross Area
one hectare & above)
b.1 Areas allocated for Parks Mandatory Allocation for Parks and Playgrounds Per Tabulations Below
& Playgrounds (1 Hectare Density % of Gross Area Density
& above) (No. of Lots/ Allocated for (Dwelling Units per Hectare)
Dwelling Units Parks and
Per Hectare Playgrounds
NOTE: In no case shall the Area be less than 100 square meters
BP 220
SOCIALIZED HOUSING
Same as PD 957
a. variable
b. see open space requirement
as per b.1 and b.3
NOTE: for ROWHOUSES, there shall be a maximum of 20 UNITS but in no case shall be more than 100m in length
+ Right of way (ROW) of major roads shall be increased as project size increases. ROW shall not be lower than ROW of public road.
+ Major Roads shall maintain a uniform width of road right of way. Tapering of road width shall not be allowed
NOTE: 1. Interior subdivision project must secure right of way to the nearest public road
2. Subdivision projects with direct access to a main public road must provide sufficient setback to accommodate loading and unloading
of passengers.
3. Subdivision project shall provide provision for future expansion (see text)
2.5 hectares and below major road, minor road, motor court, major road, minor road, motor court, alley, footpath
alley
Above 2.5 - 5 hectares same as above same as above
Above 10 - 15 hectares same as above same as above
Above 15 - 30 hectares same as above same as above
Above 30 hectares same as above same as above
BP 220
SOCIALIZED HOUSING
10m
8m
4m
6m
3.5m
same as PD 957
ROW CARRIEGEWAY
10.0m 6.0m
8.0m 6.0m
6.5m 5.0m
6.0m
3.0m
3.0m
3.0m
ame as above
ame as above
ame as above
ame as above
PARAMETER PD 957 BP 220
OPEN MARKET HOUSING ECONOMIC HOUSING
NOTE: refer to supplemental rules and regulations to implement PD 963 (HLURB A.O. no. 2 series of 1994 (12 April)
10.1 Minimum Water Supply 150 liters per capita per day for 150 LCPD for 43 LCPD
Requirements household connection household Handpump
connection
10.2 Fire Protection Provision for Fire Protection shall comply with the requirements of the National Fire Protection Code (PD 1185)
+ The drainage system must conform with the natural drainage pattern of the subdivision site, and shall drain
into appropriate water bodies, public drainage system or natural outfalls.
BP 220
SOCIALIZED HOUSING
(PS) (SW)
1.0m 1.0m
0.5m 0.5m
12.1 Septic Tank Individual septic Tank conforming Individual / Communal Septic Tank
to standard design of the Sanitation conforming to standard design of
Code. the Sanitation Code.
12.2 Connection to Community Whenever possible, connections shall be made to an approved public or community sewer system subject to the
Sewer System requirements and provisions of the Sanitation Code and other applicable rules and regulations with regards to
materials and installation practices.
Installation practices, materials and fixtures used shall be in accordance with the provision of the Electrical Code
and local utility company.
14. GARBAGE DISPOSAL Provide sanitary and efficient refuse collection and disposal system whether independently or in conjunction
with the local government garbage collection and disposal services.
a.1 Single-Detached Shall conform with the National a.1 22 sq. meters
Building Code (PD 1096) and local
Zoning Ordinance
a.2 Duplex a.2 22 sq. meters
a.3 Rowhouse a.3 22 sq. meters
NOTE: Minimum floor area shall be in one floor level exclusive of mezzanine
floor if any.
b. Mnimum Level of
Completion
NOTE: Minimum floor area shall be in one floor level exclusive of mezzanine
floor if any.
1.50 meters
2.0 meters
2.0 meters
Building Code (PD 1096)