You are on page 1of 1

- 1200mm x 600mm, 2 X 28W T5 FLUORESCENT FITTING

( NORMAL SUPPLY )
- 600mm x 600mm, 2 X 28W T5 FLUORESCENT FITTING
( NORMAL SUPPLY )

- 1 X 28W T5 FLUORESCENT FITTING ( NORMAL SUPPLY )

EXIT - 435mm x 240mm EXIT SIGN


A A1 B B1 C D E E1 F G G1 H H1 H2 H3 J
- 635mm x 100mm EMERGENCY LIGHT
64000 EL
3000 6000 7500 7500 8000 8000 7500 7500 6000 3000
- DETECTOR

- 1200mm x 600mm SUSPENDED PLASTER CEILING


(ref. type of ceiling fin.)

- ALUMINIUM STRIP CEILING


(ref. type of ceiling fin.)

9 - 600mm x 600mm PERFORATED FACE RETURN AIR GRILL


3000

- 300mm x 300mm PERFORATED FACE RETURN AIR GRILL

8a
- 600mm x 600mm SQUARE CEILING DIFFUSER
6000

- 1200mm x 250mm LINEAR DIFFUSER

8 1. All dimensions are in milimeter U.N.O


- SETTING POINT 2. All suspended ceiling shall be Acoustic ceiling except for Toilet, Pantry and Prayer Room/Ablution shall
be Moisture resistant ceiling.
7a
7500

CH - CEILING HEIGHT 3. False floor height shall be 800mm minimum.


4. Battery room, UPS room, HVAC room and other related rooms, the equipment access
TYPE OF CEILING FINISHES door size shall be confirmed with the size of the equipment.
5. Abbreviations :
7 USG BORAL - IMPRESSIONS CLIMAPLUS 600 x 1200 x 16 tk.mm APC - Advanced Process Control
'SQ' (NRC - 0.6 MIN.) SUPPORTED ON OTAIYO SUSPENSION CTR - Central Technical Room
CEILING SYSTEM EER - Electrical Engineering Room
IER - Instrument Engineering Room
7500

PRIMA - MOISTURE RESISTANT CEILING PANEL 600 x 1200 x 3.2 tk. mm MR - Meeting Room
SUPPORTED ON OTAIYO SUSPENSION CEILING SYSTEM OC - Operator Console
OTR - Operator Training Simulator Room
6 OER - Operation Engineering Room
OPA - Operating Area
PERTAC - ACOUSTIC CEILING PANEL 603 x 1212 x 20 tk. mm OPZ - Operating Plant Zone
(NRC 0.8 MIN) SUPPORTED ON OTAIYO SUSPENSION PTW - Permit to Work
8000

SYSTEM
5a UPS - Uninterruptable Power Supply
CCR - Central Control Room
PLASTERBOARD CEILING (CLASS 0) BORAL UNISPAN : 9.5mm tk. x 2 LAYERS OPC - Operating Company
TO COMPLY TO TRS REQUIREMENT APR - Advanced Process Control Room
64000

5 OTR - Operating Training Simulator Room


S.O.P - Set out Point
6.Visitor and waiting rooms shall be designed such
DML 100G ALUMINIUM STRIP CEILING that no visibility allowed to the Central Control Room (CCR).
8000

0.4 mm (ALUZINC PANEL) 7. Please refer to M&E LIGHTING LAYOUT DRAWING - RAPID-P0014-0007-ELE-DWG-6710-1018
0.5 mm (ALUMINIUM PANEL) 8. Please refer to M&E DUCTING LAYOUT DRAWING - RAPID-P0014-0007-HVA-DWG-6710-1007
4a COLOR : WHITE 9. Please refer to TELECOM LOCATION & CABLE ROUTING LAYOUT
- RAPID-P0014-OUI-NVT-DWG-6710-1100_0
4 10. Size of the door for the Telecom Room already been advised by M&E consultant.
11. For construction as requested by BP ( In Colour)

3a
7500

3
7500

2a

2
Digitally signed by Digitally signed by
Digitally signed by Irwan Kanvinchelvan A/L
Dzafir Bin Sudirman Moghana Sundaram Kanagarajah
Date: 2017.03.09 17:04:33 Date: 2017.03.09
6000

Date: 2017.03.09 17:05:18


+08'00'
17:04:59 +08'00' +08'00'

1a
3000

PRPC Utilities and Facilities Sdn Bhd

ARCHITECTURAL DETAIL DRAWING


MAIN CONTROL BUILDING (6710-MCB-601)
MCB FIRST FLOOR REFLECTED CEILING PLAN (2ND LAYER CEILING) @ 4500 mm ht and 9000 mm ht FIRST FLOOR REFLECTED CEILING PLAN (2ND LAYER CEILING) @ 4500 mm ht. and 9000 mm ht.
MAIN CONTROL BUILDING (6710-MCB-601)

You might also like