LIGHTING ON BOARD
Luminaires, (EX) stainless steel floodlights for HPS and MH lamps
Navigation lights (EX proof)
Low Location Lighting
OTHER PRODUCTS
Fixed Fire Fighting equipment/Watermist systems/
Local application systems
Signalling columns
Fire Detection 2
Consilium catalogue fire detection
Gas Detection 3
Consilium catalogue gas detection
Sensepoint XCD
Certificates 4
Reference list 5
1
Marine Fire Detection
and Alarm Systems
CONVENTIONAL SYSTEMS
OPERATOR PANELS FOR CONVENTIONAL SYSTEMS .......................................................................... 9
DELTA COMPACT CONTROL PANELS - CONVENTIONAL ................................................................... 10
DELTA SUB PANELS, DECENTRALIZED - CONVENTIONAL ................................................................. 10
DETECTORS CONVENTIONAL RANGE ............................................................................................... 11
BASES FOR CONVENTIONAL ORBIS DETECTORS .............................................................................. 12
MANUAL CALL POINTS CONVENTIONAL SYSTEMS ............................................................................ 13
ADDRESSABLE SYSTEMS
OPERATOR PANELS FOR ADDRESSABLE SYSTEMS.......................................................................... 14
DELTA COMPACT CONTROL PANELS - ADDRESSABLE ..................................................................... 14
DELTA SUB PANELS, DECENTRALIZED ADDRESSABLE.................................................................. 15
DETECTORS IQ8QUAD RANGE ........................................................................................................... 16
DETECTORS IQ8QUAD RANGE WITH INTEGRATED ALARM DEVICES ........................................... 18
BASES FOR ADDRESSABLE IQ8QUAD DETECTORS ........................................................................... 20
MANUAL CALL POINTS FOR ADDRESSABLE SYSTEMS...................................................................... 21
I/O and ADDRESS UNITS ......................................................................................................................... 22
ALARM DEVICES
ALARM DEVICES ACOUSTICAL ........................................................................................................... 36
ALARM DEVICES ACOUSTICAL/OPTICAL ........................................................................................... 36
ALARM DEVICES OPTICAL .................................................................................................................. 37
LOOP POWERED ALARM DEVICES ....................................................................................................... 38
ATEX ALARM DEVICES ........................................................................................................................... 39
MISCELLANEOUS
NETWORK and COMMUNICATION MODULES ....................................................................................... 44
ACCESSORIES ......................................................................................................................................... 45
DETECTOR LABELS................................................................................................................................. 47
Sales
Our products are distributed through a worldwide network of dedicated partners, agents and/or distributors, offering
our global operating customers local support and technical know how. Please contact our local partner in your
region for prices, contact information is found on the Eltek by Honeywell marine WEB site (www.eltek-fs.com).
Engineering
Our marine engineering department provides tailor-made solutions based on customer inputs, class requirements
and system design. The demand for safety, reliability and user friendliness is always considered. This requires
know-how built up during decades through our engagement in the marine market.
Field Service
Honeywell Life Safety AS is represented worldwide through a network of highly skilled and authorized partners
providing system sales, system design, commissioning, service and after sales support to ship owners and ship
yards. On-site service is also provided by a dedicated team of Field Service Engineers ready to travel on short
notice to any regions of the world.
For online support your find TechZone on our webpage www.eltek-fs.com which is an internet service for the
distribution of technical publications and other information. As a VIP-member you will get access to publications
concerning installation, service guidelines, operation, trouble- shooting, other technical documents and the
opportunity to download software.
----------------------------------------------------------------------------------------------------------------------------------------
Marine approvals
Our products for marine applications are approved by the major classification societies; hence both our
production is evaluated and subsequently our deliveries are suited for the environmental conditions that might
occur onboard. Please check our internet site for more information on the type approvals for our Marine
products.
By choosing an Eltek Fire & Safety branded Fire Detection and Alarm Solution from Honeywell Life Safety you
obtain a system with increased safety focus, reduced installation cost, easy maintenance, less spare parts and a
solution which compliance with the various requirements for fire system applications. From the same basic
modules we provide customised system solutions to suit your needs.
The embedded DELTA Technology has the unique features you would find in all the Eltek Fire & Safety branded
Fire Detection and Alarm System. Self-developed, cutting-edge technology offers users unsurpassed safety with
flexibility for future upgrading and expansion. The system philosophy enables communication between different
products and platforms. The result is maximum safety, greater user friendliness and maximal overall economy.
The Delta System support both Esser and Apollo detector loop protocols.
Our products for marine applications are approved by the major classification societies; hence both our production
is evaluated and subsequently our deliveries are suited for the environmental conditions that might occur onboard.
Please check our internet site for more information on the type approvals for our Marine products.
Delta Technology:
An expression covering Eltek Fire & Safety branded modular Fire Detection and Alarm Systems - EN54 compatible
and marine approved system components utilizing the latest technology in network systems and alarm signal
evaluation.
Delta Compact:
Eltek Fire & Safety' branded Fire Alarm Panel, featuring in one cabinet the following modules as standard: Delta
OP, Delta DA and batteries.
Delta NET:
Fire Alarm Network where Delta Modules communicate via 2 two wire cables, where one is used as an Emergency
Alarm Line (Hard Wire) and the other as an eBus.
eBus:
LON based bus for multi-master network communication between the Delta Modules. The eBus network is based
on intelligent control nodes (eNodes) that communicate with each other via eComm.
eComm:
Proprietary communication protocol for Delta Modules connected to the multi-master and eBus network.
eNode:
This Communication Unit is used for connecting other products such as a PC to the Delta Fire Detection and Alarm
Systems. The eNode is also used as an interface unit for other fire alarm modules connected to the multi-master
eBus network, or if you need to connect the Delta System Modules in a redundant network (double eBus network)
Small and elegant operating panel for recess mounting into consoles.
Protrudes 10 mm above its surroundings. The Delta OP small conforms to the
requirements for operating-units in fire-alarm networks
Communication:
Art. no. 251242 Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc.. NMEA 0183 to VDR.
Communication:
Art. no. 251241
Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc
The operating panel is primarily used as an operating unit in Delta network system.
The Delta OP meets the NS-EN-54.2.
Features:
graphic display,
output for programmable control of 64 LEDs,
Incorporates communication port for eBus or RS 485.
Art. no. 251157.1 Input for direct PC programming of connected units
Communication:
Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc.. NMEA 0183 to VDR.
The Delta Compact is a centralised fire detection and alarm control unit that complies with
EN 54.2 and EN 54.4. The unit consists of DELTA OP control panel, DELTA DA module
(incl. power-supply), eBus and batteries for emergency operation
Features:
5 loops,
3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
Art. no. 251808.100
* May be configured for 8 zones at the sacrifice of sounder outputs
Features:
5 zones,
4 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
Art. no. 251072.5
Supplied with built-in batteries for emergency operation.
* May be configured for 8 zones at the sacrifice of sounder outputs
The Delta unit is a decentralized fire detection and alarm control unit that complies with EN
54.2 and EN 54.4. The unit may be used together with the DELTA OP or as either a stand
alone control unit in a network. The Delta unit consist of a Delta DA module (incl. power-
supply), eBus and batteries.
Features:
10 zones,
4 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
Art. no. 251073.10
Supplied with built-in batteries for emergency operation.
* May be configured for 16 zones at the sacrifice of sounder outputs
Features:
5 conventional zones*,
Art. no. 251245.2 4 monitored voltage outputs (e.g. alarm-bell circuits),
2 voltage-free relay outputs
1 eBus (LON-kit)
IP 65
Internal dia: 100,5mm
Useful internal depth: 30mm
Material: Polycarbonate
Weight. 100g
Supplied with: 2x self tapping 4,2x16 screws, gasket, 3xPG16 glands, 1xPG16 plug.
Art. no. 235562
Note: Mounting Frame (251437) can be used in flush mounted application. Not mandatory.
Sealed Manual Call Point. Resistor Kit included (220, 470, 680, 1K8). 1 pcs Cable Gland
The Cable of PG16STR type (06-12 mm) is enclosed in the package. PG16ST (09-14mm)
glands can be ordered on article#: 10764.
Protection Cover
Communication:
Art. no. 251242 Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc.. NMEA 0183 to VDR.
The operating panel is primarily used as an operating unit in Delta network system.
The Delta OP meets the NS-EN-54.2.
Features:
graphic display,
output for programmable control of 64 LEDs,
Incorporates communication port for eBus or RS 485.
Art. no. 251157.1 Input for direct PC programming of connected units
Communication:
Slave/master on RS 485 and network, eBus on RS 232 and external communication on
RS 232 with provision for hook-up to printer, PC, beeper etc.. NMEA 0183 to VDR.
Features:
2 loops,
3 monitored voltage outputs (e.g. alarm circuits),
Art. no. 251062.100 2 voltage-free relay outputs
1 monitored multi-function output.
Features:
2 analogue loops,
3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
Art. no. 251809.2 1 monitored multi-function output.
Features:
4 analogue loops,
6 monitored voltage outputs (e.g. alarm circuits),
4 voltage-free relay outputs
Art. no. 251809.4 2 monitored multi-function output.
The Delta unit is a decentralized fire detection and alarm control unit that complies with EN
54.2 and EN 54.4. The Delta unit consist of a Delta DA module (incl. power-supply), eBus
and batteries. Solid Rittal cabinet with gable gates for professional installation
Features:
4 analogue loops,
6 monitored voltage outputs (e.g. alarm circuits),
4 voltage-free relay outputs
Art. no. 251814.4
2 monitored multi-function output.
The Delta unit is a decentralized fire detection and alarm control unit that complies with EN
54.2 and EN 54.4.. The Delta unit consist of a Delta DA module (incl. power-supply), eBus
and batteries. Solid Rittal cabinet with gable gates for professional installation
Features:
6 analogue loops,
9 monitored voltage outputs (e.g. alarm circuits),
6 voltage-free relay outputs
Art. no. 251814.6
3 monitored multi-function output.
Features:
Art. no. 251800.21 2 analogue loops,
3 monitored voltage outputs (e.g. alarm-bell circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
1 eBus (LON-kit)
The new and unique IQ8Quad detector generation combines unique detection technology with high class design and
set new standards in terms of appearance, safety and effectiveness. The IQ8Quad Detector range provides security
you need by implementing detection, optical alarm, acoustical alarm and voice alarm embedded in one housing.
IQ8QUAD is by far the most advanced detector range in the marine market. All versions are equipped with a 360
degree visual alarm indicator and non volatile memory log for all events.
Features:
-wide angle optical chamber with signal processing for fast and reliable smoke detection
Art. no. 802371. MAR
Features:
Art. no. 802374.MAR - detection using the forward and backward scatter principle
- advanced dual chamber signal processing for unparalleled false alarm rejection
Features:
Art. no. 802375 - wide angle optical chamber with signal processing for fast and reliable smoke detection
- optical system based on blue light increases particle detection bandwidth and response
Features:
Art. no. 802473 - wide angle optical chamber with signal processing for fast and reliable smoke detection
- CO detection element contributes to faster response to glowing fire starts.
Features:
- constant response behaviour for detecting slowly and quickly rising temperatures
Art. no. 802171
Features:
Art. no. 802271 - ROR feature ensures fast response to slowly and quickly rising temperatures
The IQ8Quad smoke detectors with built-in alarm device incorporate up to 4 different functionalities depending on the
type of detector:
ALARM SIGNALING
The alarm signaling function is activated by the control panel. No further short address needs to be allocated. It
is programmed with the FireWin Explorer commissioning and configuration application.
The sound level [dB(A)] can be set to eight levels, from approximately 64dB (A) to approximately 92dB (A).
Multisensor detector with two built-in optical smoke sensors with different scattered light
angles as well as additional heat detector sensor evaluation for detecting everything from
smouldering fires to open fires with consistent response behaviour. Smoke signal
identification to ensure smoke classification and reduction of deceptive alarms caused, for
instance, by water vapour or dust
Art. no. 802383
Features:
-detection using the forward and backward scatter principle
-loop powered optical alarm signalling device
-advanced dual chamber signal processing for unparalleled false alarm rejection
-integrated optical alarm device
Features
-soft-start mode for optimum protection against sudden exposure to acoustic alarm
--detection using the forward and backward scatter principle
-loop powered optical alarm signalling device
-advanced dual chamber signal processing for unparalleled false alarm rejection
-integrated optical and acoustical alarm device
Detector base with relay contact output for the IQ8 detectors range.
Contact: floating NO.
Note: Not to be used with IQ8QUAD detectors with integrated alarm device
Note: Not to be used with IQ8QUAD detectors with integrated alarm device
Transparent plastic cover to be used together with art.no 804971 for IP55 application
Art. no. 704965
Mounting Frame for IQ8 Manual Call Point
Mounting Frame can be used in flush mounted application.
Not mandatory.
IP rating: 55
6 x PG 13,5mm cable glands
Art. no. 251595 Size: 11x15x15 cm.
Product Catalogue Eltek F&S Marine 22 (52)
Equipment for Special Applications
An address module to be used when connection article# 242923 and 242963.01 to a Delta
Esser System.
IP rating: IP54
Art. no. 805864 Loop powered
Output: 1 relay NC/NO
No longer in production will be phased out during 2012
Features:
Unlike UV and UV/IR detection, not blinded by oil mist in machinery spaces
Reduces cabling, no interface required
No additional power source required
Art. no. 243019.100 Easy installation, uses a common plug in base for smoke and heat detectors
The unit consists of a 230VAC/12VDC converter and the refurbishment transponder unit art
Art. no. 251811.10 no 808630.
The unit consists of a 24VDC/12VDC converter and the refurbishment transponder unit art
no 808630.
Art. no. 251813.11
Loop powered
Sensitivity: The detector detects a yellow flickering flame of approximately 0.1m or a
Art. no. 233007 clear flame of 0.25m at 25m.
Field of view: Approximately 90
Sensitivity setting: Class 1 or Class 3.
Operating temperature 40C to +70C, Relative humidity 95% (no condensation)
IP rating 66
The detectors are automatically coded when they are mounted onto the base. A
Art. no. 235101 replaceable plastic key contains a code that tells the detector where it is placed in the
sequence of numbers. This means that the detector can be replacedvwithout addressing
Art. no. 235140 (key card) the detector itself.
Art. no. 235128 w/isolator
Art. no. 235101.001 w/relay
The Flame Detector Bracket is an optional accessory for the Intelligent Flame Detectors. It
is a stainless steel mounting bracket adjustable in two axis.
The bracket allows the flame detector to be adjusted to the desired angle according to the
monitored area or object
Art. no. 233010
IP 65
Internal dia: 100,5mm
Useful internal depth: 30mm
Weight. 100g
Supplied with: 2x self tapping 4,2x16 screws, gasket, 3xPG16 glands, 1xPG16 plug.
Art. no. 235562
Features:
2 analogue Apollo loops
Art. no. 251244.1 4 monitored voltage outputs (e.g. alarm-bell circuits),
2 voltage-free relay outputs
Features:
2 analogue Apollo loops
3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
Art. no. 251072 1 monitored multi-function output.
in normal conditions
with a single fault for ib classification
with any combination of two faults for ia classification
In any of these conditions, every component must remain cool enough to not ignite the gases for which it is
approved. The I.S. technique restricts the useful power to about 1W, which is sufficient for most modern
instrumentation. It is also safe for personnel, since the voltages are low and it allows field equipment to be
maintained and calibrated live, without the need to obtain a gas-free certificate.
Features:
Art. no. 803371.EX -wide angle optical chamber with signal processing for fast and reliable smoke detection
Features:
Art. no. 803271.EX
- ROR feature ensures fast response to slowly and quickly rising temperatures
The barrier separates inherently safe from non inherently safe circuits outside the
hazardous area (Ex zone). The detectors are installed as spurs from the Ex barrier into
the hazardous area, no closed loop wiring is permitted.
The barrier must be installed in the safe area close to the Ex zone, for example in part no.
251595 or another suitable housing
Art. no. 804744
IQ8 base
Conventional
IP rating: 66
Art. no 251561 The EXi MEDC manual call point can be connected directly to a DA module or an address
module, 804869, through zener barrier, 07096/2.
Conventional
IP rating: 67
Atex certified
The KAC manual call point can be connected directly to a DA module or an address module,
Art. no. 251617.Ex 804869, through zener barrier, 07096/2. Sealed Manual Call Point. 1 pcs Cable Gland
PG16STR type (06-12 mm) is enclosed in the package. PG16ST (09-14mm) glands can be
ordered on article#: 10764.
The 601FEx-M is a full featured solar blind flame detector for enclosed use and boasts a
high degree of false alarm immunity. The 601FEx-M is an intrinsically safe version intended
for use in hazardous atmospheres.
Unlike UV and UV/IR detectors, it is not blinded by oil mist in machinery spaces
Reduces cabling, no interface required
Art. no. 243019.200 Delivered complete with sealed base
The 601FEx-M can be connected directly to a DA module through zener barrier 07096/2, or
to an Address unit for conventional detectors, 251811.10 or 251813.10 through zener barrier
07099.
Conventional Manual call points must be connected to the addressable detector loop by an
address unit and a Zener barrier.
The unit is meant for DIN rail mounting. It can also be mounted in enclosure article 251595
Art. no. 804869
This Zener Barrier is used when conventional EX manual call points are connected directly
to the conventional zones on the Delta Detection and Alarm Module (Delta DA) or to an
Address unit for EX manual call points (804869)
Art. no. 07096/2
The unit is meant for DIN rail mounting. It can also be mounted in enclosure article 251595
This Zener Barrier is used when conventional EX Detectors are connected directly to the
conventional zones on the Delta Detection and Alarm Module (Delta DA) or to an Address
Art. no. 07099 unit for conventional detectors (251811.10)
The unit is meant for DIN rail mounting. It can also be mounted in enclosure article 251595
(see page 22)
IP rating: 55
6 x PG 13,5mm cable glands
Size: 11x15x15 cm.
The addressable XP95 Intrinsically Safe (IS) Detectors are a development of the well-established intelligent XP95 range of
detectors. They feature all the benefits of the standard range, but are developed specifically for use in hazardous
areas. The XP95 IS detectors are connected to the Delta Fire Detection System through Delta Apollo Detection and Alarm
Modules (DA Apollo) available as separate DAs or as 2 loops or 4 loops SUB Panels.
Addressable XP95 IS detectors and addressable XP95 IS MCPs is connected to the loop through Protocol Translators and
Galvanic Barriers (ref attached drawing). A total number of 4 pcs Protocol Translators/channels can be connected to each
loop providing a total of 72 (18 pcs per spur) IS detectors per loop. The maximum spur capacitance is 70 nF.
For safe areas we recommend to use the IQ8 Quad Detector range together with Delta Quad Detection and Alarm
Modules. The Delta Quad DA Modules can be mixed with the Delta Apollo DA Modules on the same Delta Network.
Cost-effective Detection and Alarm Module for decentralised solutions. Communicate with
Apollo detectors and fully meets EN 54.2 requirements regarding fail-safe networks. The
Delta DA is operated via the Delta OP panel and is designed for hook-up to other Delta
DA modules. Delta DA is equipped with a communications output for direct hook-up (via a
LON-kit) to other Delta Units
Art. no. 251244.1
Features:
2 analogue Apollo loops
126 detectors per loop
3 monitored voltage outputs (e.g. alarm-bell circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
1 eBus (LON-kit)
Approvals: Complies with EN54.2 and EN54.4
Features:
2 analogue Apollo loops
126 detectors per loop
Art. no. 251072 3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
Features:
4 analogue Apollo loops
126 detectors per loop
Art. no: 251073 3 monitored voltage outputs (e.g. alarm circuits),
2 voltage-free relay outputs
1 monitored multi-function output.
The XP95 IS Mounting Base has been designed to accept only IS products. This ensures
that standard detectors inadvertently be fitted into an intrinsically safe system.
Detector base for watertight installations applicable for the XP95 and Discovery detectors
range. To be used in machinery spaces and similar areas were there may be humid and
wet conditions.
Art. no 235133
Galvanic Barrier
The Galvanic Barrier and Protocol Translator are installed in the safe area ensuring of
communication between control equipment and field devices and safety within the limits of
BASEEFA approval.
Art. No:
235131 (1 channel)
235132 (2 channels)
Protocol Translator
The Protocol Translator and Galvanic Barrierare installed in the safe area ensuring of
communication between control equipment and field devices and safety within the limits of
BASEEFA approval.
Art. No:
235138 (1 channel)
235139 (2 channels)
Acoustic alarm
Sound output: Based on the chosen 32 tones (87 - 111dB)
Voltage rating: 15 28VDC
Current consumption: 7 - 27mA
Alarm circuits must have constant voltage
IP rating: 65*
Art. no. 243120
Diameter: 92 mm
*For obtaining IP 65, sealed base must be used, article 235312
Asserta sounder
Sound output: 120dB
Voltage rating: 15 28VDC
Current consumption: 450mA
IP rating: 66
Dimensions: 168 x 168 x 155mm
Beacon XL
Red light
10 joule
24V
Current consumption: 700mA
Alarm circuits must have constant voltage
Art. no. 251584 IP rating 65
Beacon
Red light
5 joule
IP rating: 55
Voltage rating: 20..28 VDC
Current consumption: 300mA
Alarm circuits must have constant voltage
Art. no. 243118
To be used on the on the alarm output when connecting Exia Alarm Devices. Each alarm
unit must have its own isolator barrier
DIO PCB
The DIO PCB is a I/O unit used for door monitoring. The PCB can be used when
installation of door monitoring is done in a centre point in the vessel. The unit must be
connected to an Apollo DA module. Maximum 20pcs per loop.
SW: Article 08393.072, Mechanical plate for mounting of 8 DIOs: Article 21911
Art. no. 26869.003
Limit switch
The Omron limit switch, 251615, is a limit switch for monitoring the closing of fire doors.
The unit has a resin roller mounted on a metallic lever. The length of the level is adjustable
Art. no. 251605 to simplify the installation. The unit has a conduit cap for installation of a cable gland. Cable
gland is not included.
Cost-effective Detection and Alarm Module for decentralised solutions. The Delta DA is
operated via the Delta OP panel and is designed for hook-up to other Delta DA modules.
Features:
2 analogue Apollo loops
Art. no. 251244.1 4 monitored voltage outputs (e.g. alarm-bell circuits),
2 voltage-free relay outputs
Features:
2 analogue Apollo loops
3 monitored voltage outputs (e.g. alarm circuits),
Art. no. 251072 2 voltage-free relay outputs
1 monitored multi-function output.
Workstation
Monitor
Art no.: 251458 - Marine approved LCD monitors for recess mounting in bridge or control
consoles.
Size: TFT - 17.0 or 19 inch
Optimal Resolution @ Hz:1280 x 1024 @ 60 Hz
Power Supply: 24 VDC or 115/230 VAC
To be used when connecting PC or other external equipment to the Delta Modules via
RS232. The Galvanic Isolator is used to avoid earth fault when connection external units
to the Delta System and will also provide over voltage protection for both systems. Need
24 VDC supply voltage. 9 meter cable to be used between the fire alarm panel and the
Galvanic Isolator is included.
MANAGEMENT SOFTWARE
Data: Description: Notes:
FireWin Publisher
FireWin Publisher is application to be used together with Firewin Presentation and makes it
possible to publish alarm status on WEB. When an alarm or pre-alarm situation occurs, the
Firewin Publisher automatically distributes the alarm status to all PCs in a network that
have Firewin Publisher installed.
Art. no:
251414 (SW Application)
251414.01 (Clients)
Delta Terminal
Eltek Fire & Safetys Delta Terminal is a Windows application that can be installed on
laptops, PCs or PDA.s and makes it possible to remotely control and operate Delta fire
Alarm Systems through Internet/intranet. This application gives you a unique possibility to
remotely monitor and control Delta Fire Alarm installation.
eNode
This communication unit is used for connecting other products such as a FireWin PC to the
Delta fire alarm systems. The eNode is also used as an interface unit for other fire alarm
modules connected to the multi-master eBus network, or if you need to connect the Delta
System Modules in a redundant network. In this case you connect the eNode to the RS232
port on the Delta DAs. With this configuration the Delta DAs will send the system
information both directly on the eBus and through the RS232 port. If one of the
communication lines fails you will still have communication on the other.
Art. no. 235762
Note: If you are connecting the eNode to a PC or laptop an RS232 cable has to be ordered
with reference to article#: 255750.006. If you are using eNode to connect the Delta System
in a redundant network you need to order a dedicated cable to be used between the eNode
and the Delta DA. Please refer to article#: 255750.010
This unit is based on a Delta OP but without display and keypad. Used as a communication
interface for voice alarm, SMS communication, HW mimic driver (64LEDs), Timer or as an
interface between the Delta System and other alarm devices. The Delta Communication
Interface is equipped with 7 digital inputs.
A fiber-optic modem for transmission of eBus data via optic fibers. The modem is
connected directly to the Delta Modules via eBus. External 24V DC supply voltage is
required. This allows the user to build either a bus- or redundant ring topology through
fibre. A distance of 5 km can be achieved by using Multi Mode fiber (standard version).
The transmission distance can be up to 24 km by using a Single Mode fiber (available on
request).
Art. no.
242671.060 multi mode
242671.065 single mode
This modem makes it possible for eBus communication between Delta Units through
Internet. The Delta System is connected to the TCP/IP Modem through a eNode (article#
235762)
The Delta DA Redundancy kit is a kit for changing over detector loops to a backup DA, in
case of a faulty main DA. The kit is in marine used for applying the system to Safe Return
to Port regulations.
Art. no. 259562
ACCESSORIES
Data: Description: Notes:
The kit consists of a printed circuit board and a cable. When the kit is installed inside the
DELTA OP it enables an input from the PA system to mute the fire alarm system.
The kit consists of a printed circuit board, a cable and a relay. When the kit is installed
inside the DELTA OP it enables the PA system to mute the fire alarm system and the
BAMS system to mute the panel buzzer
ACCESSORIES
Data: Description: Notes:
To be fitted on the IQ8 QUAD addressable detector range for dust protection.
Packing unit: 50 pcs.
Art.
no. 805589
A4 all-in-one printer
PIXMA MG5150 is an advanced, feature-rich All-In-One with 5 Single Inks, Auto Duplex
print and 2-way paper feeding. Get to the function you need more quickly with Quick
Operation & 6.0cm TFT display. The printer is well suited for printing of screendumps from
FireWin Presentation.
DETECTOR LABELS
Data: Description: Notes:
ELTEK programming hand held tool for setting addresses for the IQ8 / IQ8QUAD
detectors. The tool is recommended to be kept onboard for easy programming if a detector
is to be replaced.
The Tools 8000 is a PC application allowing you to configure and read status of the IQ8
Quad Detectors. The Tools 8000 can be used for a range of tasks, supporting the entire life
cycle of the system from installation to regular preventive maintenance. The kit contains
the Tools 8000 application and a I/F to be used when connection the laptop or PC to a
single detector or a detector loop.
Art. No. 789860
The cable between the FireWin PC and the eNode. Galvanic isolator is included in the
cable. Cable length: 9 metre
TEST EQUIPMENT
Data: Description: List price:
Test gas
Flame Detector Test Kit for 601 series IR Flame detectors. p/n
243019.100 and 243019.200
T110 Infra-Red Test Source with T110 Adaptor for 601F/801F Detector
The Flame Sensor Test Kit is a tool which is designed to test flame detectors without
the need of real flames.
Mimics the characteristics of real flames
Demo suitcase
Demo suitcase for demo purposes. Suitcase contains one Delta OP Marine, one DAQ, one
GA button, detectors, bases and manual call points. The system is programmed and ready
to use. The suitcase is used for demonstrating detectors, manual call points and GA button.
IQ8Quad detectors are programmed with sound, speech and GA sound.
Demo suitcase 49
Detector labels 47
6 Detector remover for IQ8QUAD detectors 48
DIO PCB 40
601FEx-M Conventional Flame Detector IS 30 Door control and monitoring unit 40
Door release switch 40
DOOR RETAINER: GPT/AG W/Release button 40, 45
A Dot Matrix PRINTER for built in solutions 46
Dust cover IQ8 46
A4 all-in-one printer 46 Dust cover IQ8 QUAD 46
Acoustic alarm 36
Acoustical and optical alarm unit, 24VDC 36
Address unit for conv. detectors 230 VAC/12 VDC 24 E
Address unit for conv. detectors 24 VDC/12 VDC 24
Address unit for EX manual call points 31 Eltek detector programmer 48
Address Unit: 12 Relays 22 Eltek heat detector te 49
3
Addressable IR Flame Detector 25 Enclosure for DIN rail TAM and Zener barriers 31
Addressable UV Flame Detector 55000-027MAR 25 Enclosure for Technical Alarm Module, p/n 804869 22
2
Addressable UV/ IR Flame Detector 25 Enclosures for I/O and address units 22
Alarm siren DB7 EExia 39 eNode 44
Alarm Sounder BExS110 39 Esser Address Unit 1 in/1 out IP54 23
Asserta sounder 36 Esser Refurbishment Address Unit, 4 IN / 2 OUT 22
Esser Tools 8000, starter kit 48
EX Connection Unit (235131 + 235138) 35
B
D G
The Eltek Fire and Safety brand is represented worldwide Engineers ready to travel on short notice to any regions of the
trough a network of highly skilled and authorized partners world. Service performed by authorized personnel mean that
providing systems sales, system design, commissioning, service quality is maintained year after year and guarantees that repairs
and after sales support to ship owners and ship yards. On-site and service is performed in accordance with manufactures
service is also provided by a dedicated team of Field Service specifications.
2012/01 Electronic pdf edition Subject to change without notice - 2011 Honeywell International Inc.
Our mission is to protect human lives, assets and the We hold a strong position by offering service and sup-
environment and to make a difference when safety mat- port all over the world which is an important criteria
ters. for shipping companies as well as shipyards when making
investment decision.
Business development
Based on our market and technical knowledge, we invest Marine & Safety business area also offers safety solutions
in new areas and currently have a number of interesting for land transportation and building safety and we have
business development projects in our portfolio. Many established ourselves as a leading supplier of fire detec-
business projects have developed beyond expectations, tion solutions for trains.
which has resulted in new separate business areas and
separate divisions or new products and solutions. This is Fire safety & Automation
the case with products and systems for military vessels, In the Fire safety & Automation business area, Consilium
special radar system for detection of oil spills, port sur- supplies automation products as well as fire and safety
veillance, ECDIS and integrated navigational systems. systems for oil and gas plants. The product range includes
instrumentation, control systems, automated inventory
management for tank farms and terminals, solutions for
fire and gas detection, oil and gas pipeline leak detection,
fire extinguishing systems, emergency shut down systems
and communication systems.
4 5
Salwico Fire Detection System Salwico Fire Detection System
Salwico Cargo Fire Detection Centrals
Salwico Cargo, with integrated control panel
Salwico Cargo is a fully SOLAS compliant fire detection central. It is supplied both as
analogue addressable or conventional version. Tested and certified by all the major
classification societies, this system provides optimal fire detection for merchant ves-
sels. Salwico Cargo cabinet is in some versions featured with general alarm system.
The control panel is embedded into the main cabinet and it provides possibility to
attach remote control and repeater panels to the main cabinet.
Salwico Addressable
F400-101-X010YA
Salwico Cargo,, with integrated control panel
2 -6 loops and 8-16 relays alt.
F800-101-X010YA 8 - 32 Conventional Sections and 8-16 Relays
Conventional Addressable
F000-101-XY100A 000 = 440x400x180 Cabinet / 010 = 440x570x180 Cabinet
X = No of relay modules 1 or 2,Y = No of loop modules 2 - 6
Conventional
X = No of relay modules 1 or 2,Y = No of I/O 70 module 1 - 4
6 7
Salwico Fire Detection System Salwico Fire Detection System
Control/Repeater panels Buscon M 10 H
Control/Repeater M 4,3 Cargo
BusCon M 10 has two major functions:
The Control/Repeater Panel M 4.3 is a control panel with a 4.3 graphical colour Terminal board for functions in Control Panel M4.3 and Control/Repeater M4.3
display used to manage and supervise a system. It mounts on any flat surface inde- Terminal board for Backbone Bus External BBE (RS485 Repeater)
pendently from a fire alarm cabinet and is equipped with communication buses for These functions can be used together or individually. The module BusCon M 10 has
connecting to the system. USB In front of the panel provides easy access to the one connection for either RS232 or RS485 communication. For details on assembling
systems data and diagnostic logs. It also provides the following features: a system and definitions of common system terms, refer to the Installation Manual.
A backlit 4.3 graphical colour display Alarm buzzer LED status indicators Note! BusCon M 10 does not provide a galvanically isolated bus communication BBE.
Backbone Bus Interface Ethernet connection RS-422/RS-485 serial interface Operating voltage range 19-30 VDC
RS-232/RS-485 serial interface Three USB interfaces Two configurable pow-
ered I/Os Two programmable relay outputs
5100056-01A
5100195-20A
5100054-01A
Control M X H
Bus Isolator
Control M X is used in three different ways:
Bus Isolator M divides the system backbone bus into segments. Its dual functional-
As a central controller (Master) in a Fire detection system.
ity isolates communications and basic backup signals between the stretched system
As a central backup controller (Slave) in a Fire detection system.
parts and provides power to the control panel (e.g. Control Panel M 4.3). For details
As a provider of additional communication channels, additional external communi-
on assembling a system and definitions of common system terms, refer to the Instal-
cation, or as an extension bus.
lation Manual.
A Control M X provides the following features:
Ethernet connection RS-422/RS-485 interface
RS-232/RS-485 interface Two programmable relay outputs
For details on assembling a system and definitions of common system terms, refer to
the Installation Manual. 5100071-01A
5100002-02A
Loop M X H I/O M 70 H
Loop M X enables the connection of one addressable detector loop. For details on I/O M 70 provides eight programmable I/O 70 channels, each individual channel can
assembling a system and definitions of common system terms, refer to the Installa- be configured as either:
tion Manual. Programmable Inputs
Programmable Outputs max 70mA for buzzers, relays etc
Conventional detector zones
This module monitors conventional detectors, digital inputs, two-wired inductive
sensors and controls low-power units, such as buzzers and relays. For details on as-
sembling a system and definitions of common system terms, refer to the Installation
Manual.
5100026-01A 5100075-01A
8 9
Salwico Fire Detection System Salwico Fire Detection System
I/O M 700 H
Change Over M EXT H
I/O M 700 provides eight programmable I/O 700 channels, used for either:
Programmable Inputs Change Over M Ext monitors mains and emergency power inputs and gives fault in-
Outputs max* 700 mA for magnets, power supply etc dication if either supply is lost. The power input status is indicated by the front panel
Use the I/O M 700 as an input module, or use it to monitor, control, and/or supply LEDs. Change Over M Ext provides two separate controllable 230 VAC outputs,
units such as alarm devices, magnets. It can also provide constant power supply to OUT 3 and 4, protected by separate front mounted fuses. There are also two sepa-
other system modules such as Control and Repetar Panels etc. For details on as- rate programmable change over relays, OUT 5 and 6. OUT 3-6 are used to control
sembling a system and definitions of common system terms, refer to the Installation units such as sirens, magnets, flashlights, alarms and ventilation fans. For details on
Manual. assembling a system and definitions of common system terms, refer to the Installa-
* Used as an output module, I/O M 700 can provide max output 1400 mA, if two tion Manual.
outputs are connected together.
5100077-01A 5100068-01A
Relay M 8 H
PSU M AC/DC 5A
Relay M 8 provides eight programmable relay contacts. Each of these relay contacts
provide a potential free change-over contact. Use Relay M 8 to control units such PSU M AC/DC 5A powers the system. It is shortcircuit proof and can be used in
as sirens, magnets, flashlight, alarms and ventilation fans. For details on assembling a pairs to supply 5+5 A. For details on assembling a system and definitions of common
system and definitions of common system terms, refer to the Installation Manual. system terms, refer to the Installation Manual.
5100081-01A 5100087-01A
Charger M provides power to the system through the Backbone Bus. It connects to The Dimension CD-Series offer DIN-rail DC/DC converters in the 92-120W output
either a change-over module or directly to a power supply, supervises change-over power range in a very compact housing. These DC/DC converters are allowed to
and connects the power supply units. By using dual Charger M modules, it is possible run with a battery or similar sources or can also be used to refresh and stabilize the
to replace one Charger M module without powering down the system. For details on 24Vdc on the end of long cable runs. The basic units include all the essential basic
assembling a system and definitions of common system terms, refer to the Installa- functions while the -S1 version is equipped with quickconnect spring clamp terminals,
tion Manual. a DC-OK-contact which monitors the output and an input-low-relay-contact. The
L1 version additionally fulfills the NEC Class 2 requirements. All devices except the
CD5.241-L1 have a PowerBoost of 20% incorporated. This extra power can even be
used continuously up to +45C.
5100062-01A 5100088-01A
The Change Over M X can switch automatically between two power sources, mains The Control/Repeater Panel M 4.3 is a control panel with a 4.3 graphical colour
and emergency, with preference towards mains power if both sources are opera- display used to manage and supervise a system. It mounts on any flat surface inde-
tional. The Change Over M X is used to connect to the PSU module in a system, and pendently from a fire alarm cabinet and is equipped with communication buses for
is also provided with one extra power supply outlet (which can be used for example connecting to the system. USB In front of the panel provides easy access to the
to a printer). This is a separate module without any contact with the backbone bus. systems data and diagnostic logs. It also provides the following features:
For details on assembling a system and definitions of common system terms, refer to A backlit 4.3 graphical colour display Alarm buzzer
the Installation Manual. LED status indicators Backbone Bus Interface
Ethernet connection RS-422/RS-485 serial interface
RS-232/RS-485 serial interface Three USB interfaces
5101003-50A Two configurable powered I/Os Two programmable relay outputs
5100066-01A
10 11
Salwico Fire Detection System Salwico Fire Detection System
The Control/Repeater Panel M 4.3 is a control panel with a 4.3 graphical colour Salwico Workboat is a fully SOLAS compliant fire detection central. It is supplied in
display used to manage and supervise a system. It mounts on any flat surface inde- both analogue addressable and conventional versions.
pendently from a fire alarm cabinet and is equipped with communication buses for Tested and certified by all the major classification societies, this system provides opti-
connecting to the system. USB In front of the panel provides easy access to the mal fire detection for smaller vessels. The system is managed and supervised through
systems data and diagnostic logs. It also provides the following features: Control Panel M 4.3, that ether is installed into main cabinet or supplied for instal-
A backlit 4.3 graphical colour display Alarm buzzer lation as separate unit. The cabinet is intended for wall mounting, but using it can be
LED status indicators Backbone Bus Interface recessed using additional installation kit.
Ethernet connection RS-422/RS-485 serial interface
RS-232/RS-485 serial interface Three USB interfaces
5100096-20A Two configurable powered I/Os Two programmable relay outputs
Accessories
Addressable 1-2 Addressable loops alt. 2-8 Conventional Sections
5102001-00A 2-8 Relays PSU Kit Workboat 2.5A AC/DC
5102002-00A integrated General Alarm
This PSU Kit provides an ultimate power supply AC/DC converter to Salwico Work-
5102003-00A
boat centrals when 100 or 240 VAC power is used as supply of the central. Only one
PSU kit is to be used per power supply channel, i.e. in cases when both Main and
Conventional
Emergency supply are to be connected it will be necessary to install two PSU Kits.
5102011-00A
Features
5102012-00A
Flexible 100 or 240 VAC Input Adjustable 24 VDC 5A output
5102013-00A
Long lifetime insured Status supervision and indication
5102014-00A
Installations kit included
The PSU kit is suitable for all versions of Salwico Workboat fire alarm centrals.
5102021-00A
This PSU Kit provides an ultimate power supply AC/DC converter to Salwico Work-
boat centrals when 100 or 240 VDC power is used as supply of the central. Only
one PSU kit is to be used per power supply channel, i.e. in cases when both Main and
Emergency supply are to be connected it will be necessary to install two PSU Kits or
one PSU Kit and Changeover M X. The PSU kit is suitable for all versions of Salwico
Workboat fire alarm centrals.
Features:
Flexible 100 or 240 VAC Input Adjustable 24VDC 5A output
Long lifetime insured Status supervision and indication
Installations kit included
5102021-10A
12 13
Salwico Fire Detection System Salwico Fire Detection System
5100066-01A 5200306-00A
5102023-00A 5100433-02A
14 15
Salwico Fire Detection System Salwico Fire Detection System
EV-DPH-A2R
Standard communication protocols
Salwico EV-DPH-A2R is an analogue addressable smoke and heat detector with a
Standard communication protocols available for integrations with other systems dual wavelength optical chamber. Two light sources with different wavelengths are
NMEA 0183 used, giving the detector a stable reaction to different kinds of smoke and making it
MODBUS RTU insensitive to unwanted alarms caused by e.g. water steam. Salwico EV-DPH-A2R is
MODBUS TCP/IP equipped with Omniview 360 LED indicator giving a clear, full 360 visibility of
ESPA 444 the red alarm indication. The technical detector address is set with a special pro-
gramming tool.Valid addresses are 1-254. Salwico EV-DPH-A2R is equipped with an
output for remote indication.
40050
Adressable Detectors
EV-H A1R 54C IP67
EV-P Analogue Addressable Optical Smoke Detector
Salwico EV-H is an analogue addressable heat detector molded together with base
Salwico EV-P is an analogue addressable smoke detector with an optical chamber. It is adapter SPB-ADAPT to fulfill IP67. Salwico EV-H is designed to give early warning
designed to give early warning for the presence of smoke in the supervised area. At for the presence of heat in the supervised area, and is available in two temperature
the same time the detector offers a high protection against unwanted alarms. Salwico classes: A1R (fixed 54C + rate of rise 0.8C/min) and CS (fixed 84C), see separate
EV-P is equipped with OMNIVIEW 360 LED indicator giving a clear, full 360 vis- part no. for 84C. Salwico EV-H is equipped with OMNIVIEW 360 LED indica-
ibility of the red alarm indication. The detector can be placed in harsh environments tor giving a clear, full 360 visibility of the red alarm indication. The detector can be
if it is mounted on a splash proof base. The technical detector address is set with a placed in harsh environments if it is mounted on a splash proof base. The technical
special programming tool, valid addresses are 1-254. Salwico EV-P has a fine pitch detector address is set with a special programming tool, valid addresses are 1-254.
net which improves the response to smoke and also reduces the amount of dust etc Salwico EV-H is equipped with an output for remote indication. For detailed informa-
entering the detector. Salwico EV-P is equipped with an output for remote indication. tion about appropriate systems for the detector, see separate document Compat-
040020 40001
ibility of Loop Units/System.
16 17
Salwico Fire Detection System Salwico Fire Detection System
EV-H CS 84C IP67 MCP-A Addressable Manual Call Point with inbuilt SCI
Salwico EV-H is an analogue addressable heat detector molded together with base for wet space IP67
MCP-A is an addressable manual call point, designed for the Salwico addressable fire
adapter SPB-ADAPT to fulfill IP67. Salwico EV-H is designed to give early warning for
alarm systems. The selected material PC/ABS and the encapsulation, with ingress pro-
the presence of heat in the supervised area, and is
tection IP67, makes it very suitable for harsh environment. Pressing the glass causing
available in two temperature classes: CS (fixed 84C) and A1R (fixed 54C + rate
it to crack activates the fire alarm. A protective plastic coating on the glass prevents
of rise 0.8C/min), see separate part no. for 54C. Salwico EV-H is equipped with
operator injury. An LED on the front of the call point indicates the fire alarm. The
OMNIVIEW 360 LED indicator giving a clear, full 360 visibility of the red alarm
LED remains lit until the fire alarm has been reset on the fire alarm panel. The call
indication. The detector can be placed in harsh environments if it is mounted on a
point can also be tested with a special key, included in the delivery. The address of the
splash proof base. The technical detector address is set with a special programming
call point is set with a DIP-switch. The MCP-A provides short-circuit protection via
tool, valid addresses are 1-254. Salwico EV-H is equipped with an output for remote
connections 1-4 and no short-circuit protection via connections 58.
40006 indication. For detailed information about appropriate systems for the detector, see 5200031-01A
separate document Compatibility of Loop Units/System.
EV-PP/OA130 SCI-A Short Circuit Isolator for addressable loop Units for wet space IP67
The detector is an analogue addressable optical smoke and heat detector. The smoke
The SCI-A is a short circuit isolator for outdoor harsh environment, designed for the
and heat detector functions are independent and can be used in any required com-
Salwico addressable fire alarm systems. The selected material PC/ABS and the encap-
bination. The detector is designed to give early warning for the presence of heat and
sulation, with ingress protection IP67, makes it very suitable for harsh environment.
smoke in the supervised area. The detector offers a high protection against unwanted
The SCI-A unit is placed between detectors or manual call points in the detector
alarms. The low profile combined with the Omniview 360 alarm indication makes
loop. In case of a shortcircuit in the detector loop, the SCI-A units on each side of
the detector suitable for sites with high architectural requirements. The address is set
the shortcircuit open the circuit. The address of the SCI-A is set by a DIP switch.
by an 8-way DIP-switch. The detector comes in different versions depending which
detector it replaces.
040200 5200120-00A
MCP-A Addressable Manual Call Point with inbuilt SCI for dry space IP23
I/O Units
IC44 WP
MCP-A is an addressable manual call point for indoor environment, designed for the
Salwico addressable fire alarm systems. Pressing the glass causing it to crack activates IO-unit with 4 inputs and 4 outputs in IP67 housing. Can control and
the fire alarm. A protective plastic coating on the glass prevents operator injury. An supervise single and double doors. Inputs support PNP and NPN sensors. Outputs of
LED on the front of the call point indicates the fire alarm. The LED remains lit until relay type
the fire alarm has been reset on the fire alarm panel. The call point can be tested
with a special key, included in the delivery. The address of the call point is set with a
DIP-switch. The MCP-A provides short-circuit protection via connections 14 and
no short-circuit protection via connections 58. In order to achieve IP23 the MCP-
A shall be mounted on a smooth surface and the cable inlet/outlet shall be secured
against leakage. 5200268-00A
5200030-01A
18 19
Salwico Fire Detection System Salwico Fire Detection System
5200269-00A 5200276-00A
IC10 FP10 WP
IO-unit in IP22 housing. Can be used as interface for conventional Fire patrol unit in IP67 housing.
alarming devices, control or indication.
5200272-00A 5200277-00A
IC22 WPL
IC10 WP I IO-unit with 2 inputs and 2 outputs in large IP67 housing. Can
IO-unit in IP22 housing. Can be used as interface for control and supervise single and double doors. Inputs support PNP
conventional alarming device, control or indication and NPN sensors. Outputs of relay type
5200273-00A 5200278-00A
FP10
IC20 WP
Fire patrol unit in IP22 housing.
IO-unit with 2 inputs in IP67 housing. Can be used as interface for
conventional alarming devices or controls.
5200275-00A 5200283-00A
20 21
Salwico Fire Detection System Salwico Fire Detection System
Conventional Detectors
EC-PH/A1R 58C ROR OPT S/H DET, Dry Space IP22
EC-H/A2S 58C CONV HEAT DET, dry space IP22
The EC-PH/A1R multi-criteria detector belongs to EC range of detectors. Salwico
The EC-H/A2S conventional heat detector belongs to Salwico EC range of detectors. EC is a range of conventional detectors, which have been produced using the latest in
EC is a range of conventional detectors, which have been produced using the latest in manufacturing technology and supplied with an array of advanced features. The EC-
manufacturing technology and supplied with an array of advanced features. The EC-H/ PH/A1R multi-criteria detector uses a state of the art optical chamber and a ther-
A2S thermal detector uses a state of the art thermal element combined with an ap- mal element combined with a microprocessor, running sophisticated algorithms to
plication specific integrated circuit (ASIC) to provide quick and accurate detection provide quick and accurate detection of fires. The combination of photoelectric and
of fires. The detector incorporates a static element and is suitable where ambient thermal characteristics provides a faster response to real fire situations, while at the
conditions normally exhibit rapid changes in temperature e.g. galley. The EC-H/A2S same time reducing the risk of unwanted environmentally generated alarms.
detector also has an integral LED, which illuminates to provide a local alarm signal. An
optional remote LED annunciator may be used to repeat any alarm signal.
5200172-00A 5200176-00A
EC-H/BS 78C CONV HEAT DET, dry space IP22 HC100 A2 Conventional Heat Detector (57DegC)
The EC-H/BS conventional heat detector belongs to Salwico EC range of detectors. The HC100 A2 is a conventional heat detector for use with all Salwico Fire Alarm
EC is a range of conventional detectors, which have been produced using the latest Systems. The detector is with its low profile and smooth design very suitable in loca-
in manufacturing technology and supplied with an array of advanced features. The tions with high architectural requirements such as offices, restaurants, hotel rooms
EC-H/BS thermal detector uses a state of the art thermal element combined with an and cabins. The heat sensing element is of thermistor type with a short response
application specific integrated circuit (ASIC) to provide quick and accurate detection time to changes in the ambient temperature. Alarms are optically indicated until they
of fires. The detector incorporates a static element and is suitable where ambient are reset on the central. The detector is environmentally adapted in aspects of the
conditions normally exhibit rapid changes in temperature e.g. galley. The EC-H/BS selection of material and design. The detector is polarisation independent (unless
detector also has an integral LED, which illuminates to provide a local alarm signal. An the remote output is used) which simplifies the installation. The mesh is very easy to
optional remote LED annunciator may be used to repeat any alarm signal. change and clean which simplifies maintenance.
5200173-00A 038000
22 23
Salwico Fire Detection System Salwico Fire Detection System
SWM-1KL/140, Conventional Heat Detector (140DegC) ISOLATOR-A Intrinsically Safe Isolator with enclosure for Addressable IS
Loop Units IP55, Max 20 loop units/isol.
The SWM-1KL 140 is a fixed temperature heat detector, designed for use in damp ISOLATOR-A is an IS isolator intended for use together with Salwico intrinsically
spaces. It contains a bimetallic thermostat, which closes its contacts at alarm temper- safe addressable detectors and manual call points. It contains an IS-isolator and a
ature. The detector is also available in versions with lower alarm temperature (57, 80 LISA-2 connection board. ISOLATOR-A is located in a non-hazardous area (safe area)
and 100C) and in an intrinsically safe version, SWM-1KL/IS, see separate datasheets. and forming the interface to IS detectors and other IS line units. To each addressable
detector loop a maximum of five ISOLATOR-A units can be connected, each of them
accommodating up to 20 IS line units. ISOLATOR-A does not need a separate power
supply or earth connection. It is powered directly from the fire alarm panel via the
loop cable, which means that no extra cables are needed. The cable glands shall be
mounted acc. to the dimension drawing on page two. This will guarantee the mini-
037174 N1790 mum required distance (50mm) between the intrinsic safe and the non intrinsic safe
conductors.
Manual Call Pionts EVC-PY-IS Conventional intrinsically Safe Optical Smoke Detector
MCP-C Conventional Manual Call Point for wet space IP67
Salwico EVC-PY-IS is an intrinsically safe Evolution conventional optical smoke detec-
The MCP-C is a manual call point for outdoor environment and is designed for tor. The detector is equipped with an optical sensor with improved sensitivity to
the Salwico conventional fire alarm systems. The selected material PC/ABS and the black smoke. The detector is designed for use in areas with high explosion risk. It is
encapsulation, with ingress protection IP67, makes it very suitable for harsh envi- connected to the fire alarm system via an intrinsically safe interface. Salwico EVC-PY-
ronment. Pressing the glass causing it to crack activates the fire alarm. A protective IS must not be separated from the base when energized. To avoid the possible risk
plastic coating on the glass prevents operator injury. The call point can be tested with of electrostatic charge, the unit must not be cleaned with solvents or charged by
a special key included in the delivery. rubbing.
5200014-01A N1144
60060-001010 N11890
N11255 044445
NS-ACPWP-Exn Addressable Manual Call Point for wet space IP67 SPB-ADAPT, Adaptor plate
ACPWP-Exn is a Manual call point for the addressable fire alarm systems CS4000, SPB-ADAPT is an adapter for the bases 2IP55 (part. no. 046950) and NS-2IP55
NSAC-1 and CS3000 with SPK2000. The selected material PC/ABS and the encap- (part no. 046900). SPB-ADAPT is developed to replace the adapters SPB-1 (part no.
sulation, with ingress protection IP67, make it suitable for very harsh environment. 046915) and NS-ADAPT (part no. N1421). Smoke, heat and flame detectors can be
Pressing the glass causing it to crack activates the fire alarm. The call point can also connected to this adapter. For more information about suitable bases, see separate
be tested with a special key, included in the delivery. A red LED on the front of the document Base matrix. The adapter can be used for all Salwico fire alarm systems.
call point indicates the fire alarm. The LED remains lit until the glass has been re-
placed and the fire alarm has been reset on the control panel. The address of the call
point is set with a DIP-switch. ACPWP-Exn is polarity independent which simplifies
the installation. The apparatus must be located in an area with low risk of mechanical
danger.
N11320 046916
NS-ACP-Exn Addressable Manual Call Point for wet space IP55 NS-ADAPT-IS, Adaptor for IP-55 base with N1140
The ACP-IP55-Exn is a manual call point for the addressable fire alarm system alwico The NS-ADAPT-IS is an IS (intrinsically safe) adapter for the base NS-2IP55 (part no.
CS4000, CS3000* and NSAC-1.The ingress protection IP55 makes this call point suit- 46900) or 2IP55 (part no. 46950). Only IS detectors can be connected to this adapt-
able for harsh environments. Pressing the glass causing it to crack activates the fire er. The adapter can be used for both addressable and conventional fire alarm systems.
alarm. A protective plastic coating on the glass prevents operator injury. A red LED is The NS-ADAPT-IS has an IS-label on the side. NB! The classification society might
lit on the call point when the control panel has received the alarm. It will be lit until have additional installation requirements than what is mentioned in this data sheet.
the glass has been replaced and the alarm has been reset at the control panel. The
address is set with a DIP-switch mounted inside the call point. The call point is polar-
ity independent. The apparatus must be located in an area with low risk of mechani-
cal danger.
N11321 N1422
26 27
Salwico Fire Detection System Salwico Fire Detection System
NS-ADAPT-IS2, Adaptor for IP-55 base with N11250 AC-IR-3Fq Addressable Base for AC-IR-3Fq detector
The ADAPTER AOHS-IS is an adapter for IP55 detector bases. Only detector AOHS- AC-IR-3Fq Addressable Base is suitable for installation of AC-IR-3Fq Detector in a
IS can be connected to this adapter. The adapter can be used for Salwico addressable harsh environment. The base plate provides ingress protection up to IP67, when lock
fire alarm systems CS3000, CS4000 and NSAC-1. The ADAPTER AOHS-IS has an screws are used. The base provides a termination possibility, for detector set in Ad-
IS-label on the side. NB! The classification society might have additional installation dressable mode. The address is set by an 8-way DIP-switch.
requirements than what is mentioned in this data sheet.
Features
IP65/IP67 Ingress protection
Low current draw
Suitable for installation in harsh environment
N1430 5200237-00A
EV-SPB-BI Base Adapter with Short Circuit Isolator EC-ADAPT Detector adapt for wet spaces
Salwico EV-SPB-BI is an Evolution addressable short circuit isolator in an adapter for The EC-Adapt is a connection adapter with an integrated 470Ohm serial resistor
watertight bases. It is to be used as an interface for conventional and analogue ad- for installation of EC-type detectors on the IP55 base NS-2IP55 (part no. 46900) or
dressable fire detectors. EV-SPB-BI is a watertight variant of 2IP55 (part no. 46950). This adapter is used for connection of EC-type detectors to
base EV-BI. With a conventional detector fitted on the base adapter, the address of the conventional fire alarm system, in an IP55 environment.
the isolator will be displayed by the system upon fire alarm. Removal
of the detector will also be detected and reported as a fault. The technical address is
set with a special programming tool.Valid addresses are 1-254.
5200098-00A 5200178-00A
28 29
Salwico Fire Detection System Salwico Fire Detection System
The heat detector tester VDT-1 is a gas driven heat generator for the testing of The Salwico IR test lamp is used to perform function test on Salwico IR flame detec-
conventional and analogue heat detectors. The test unit works as a normal cigarette tor. The extension rods packed in a nylon case makes it possible to easily test the
lighter and can be refilled with the same type of gas detector in all environments.
009300 001156
N1743 5200112-00A
001150 5200114-00A
Pole Solo 1,2 mtrs / Pole Solo100 1-6 mtrs stronger than 9151
UV Test lamp Portable
Pole adapter / Pole 1.4 - 4.0 mtrs
Salwico UV test lamp is used to perform function test on Salwico UV flame detec- The core element of the Solo range is the telescopic and extension access poles
tors. Salwico UV test lamp is delivered complete with rechargeable batteries and a which are extremely lightweight and quickly extend to provide access to detectors
battery charger. up to 9 metres. Light - easy to use at height, on-site, day after day Non-whip
Certified non-conductive - protecting both the engineer and overhead live equip-
ment from inadvertent shorts Available in one, two or four telescopic sections
Lifetime warranty
N1740, N1741
001155
N1744, 009151
30 31
Salwico Fire Detection System Salwico Fire Detection System
009153 006144
N1307 006131
NS-GA2/IP55 General Alarm Push Button Auto/Manual BE12, MSB-6B, alarm bell 6, red, 24VDC
for wet space IP55 The fire alarm bells are suitable for both indoor and outdoor uses since the bells
The general alarm push button NS-GA2/IP55 is designed for use in harsh environ- have aluminium/plastic housings. The operating part of BE12BE13 is a micro-motor
ments. The NS-GA2/IP55 is wall mounted and a plastic lid protects it from uninten- and of BE14BE17 a two coil vibrator. All versions have low starting currents and
tional activation. very low power consumption. If used in harsh environment the waterproof connec-
NS-GA2/IP55 has dual functions: tion box BE10, IP65, shall be used.
Auto: Activates the pre-programmed general alarm pattern. The button will stay ac-
tive until it is pressed again.
Manual: Activates the audible alarm as long as it is pressed (momentary activation).
NS-GA2/IP55 is delivered c/w two cable glands.
N1308 006132
Bells
BBX, conn. box, for 6131-34, IP65
MBA6, alarm bell 6, red, 230VAC
The fire alarm bells are suitable for both indoor and outdoor uses since the bells
Salwico MBA-6 alarm bell is intended for use with all Salwico fire alarm systems. The have aluminium/plastic housings. The operating part of BE12BE13 is a micro-motor
Salwico MBA-6 has a very high volume output matched with extremely low power and of BE14BE17 a two coil vibrator. All versions have low starting currents and
consumption. The specially designed weatherproof bell has an aluminium back box very low power consumption. If used in harsh environment the waterproof connec-
with a built-in 230Vac to 24 Vdc weatherproof mains pack (BBX-4) that allows the tion box BE10, IP65, shall be used.
bell to be powered directly from a mains supply.
The back box is given either single or double treaded for maximum flexibility in
installation.
006143 006135
32 33
Salwico Fire Detection System Salwico Fire Detection System
Sounders
Y03 Electronic siren, 24VDC, IP-66, 108 dbA MKTV-75/800 typhoon 24 VDC, 800Hz
Salwico YO3-24VDC alarm bell is intended for use with all Salwico fire alarm sys- The pneumatic alarm typhoons in the KTV and MKTV series are a maintenance free,
tems. The Salwico YO3-24VDC gives the possibility to select from 32 different tones light, rigid and powerful signalling apparatus for different applications onboard ships.
meeting international regulations. 1st and 2nd stage sound signals can be generated The typhoons can be delivered as a complete unit or the horn and the solenoid valve
by supply reversal or a connection of a 3rd wire. as separate units (see separate datasheet). For distinct signals, the piping
length between the valve and the horn should not exceed 6m. The horn is delivered
with wall bracket and filter. For explosive, corrosive or very hot areas the solenoid
valves shall be mounted separately outside the exposed area. The solenoid valve is
delivered with filter and fittings for copper piping with 10 mm OD. The solenoid
valve should not be placed outdoor without protective cover.
006250 006305
NS-ES, electronic siren, 24VDC, IP54, red. MKTV-75/800 typhoon 230 VAC, 800Hz
The NS-ES is a Roshni LP sounder that can be connected to all Salwico fire alarm The pneumatic alarm typhoons in the KTV and MKTV series are a maintenance free,
systems. It has a range of 32 tones which is set by a DIP switch. It is also equipped light, rigid and powerful signalling apparatus for different applications onboard ships.
with a volume control. The NS-ES is pre-set to tone no. 14 (970 Hz, 105 dBA (+/- The typhoons can be delivered as a complete unit or the horn and the solenoid valve
2 dBA) at 1 m). A second tone is available, which can be switched in by the connec- as separate units (see separate datasheet). For distinct signals, the piping
tion of a third core to the siren. length between the valve and the horn should not exceed 6m. The horn is delivered
with wall bracket and filter. For explosive, corrosive or very hot areas the solenoid
Part no. N1534 (white) valves shall be mounted separately outside the exposed area. The solenoid valve is
Part no. N1535 (red) delivered with filter and fittings for copper piping with 10 mm OD. The solenoid
valve should not be placed outdoor without protective cover.
N1535 006306
NS-ES, electronic siren, 24VDC, IP66, red. MKT-75/800 Typhoon without mag.valv. 800Hz
The NS-ES/IP66 is a low profile Benshee MT siren for fire and security alarm instal- A penetrating sound means a sound capable of reaching a listener on a distant vessel
lations in harsh environments. The siren is delivered with two cable glands for cable under normal noise conditions. From this respect, it is not only the sound pressure
diameters ranging from 8 to 13 mm. The base has two knockout holes for the level that is the important factor, but the content of appropriate frequency compo-
cable glands. A sound selector for 32 user selectable tones and a volume control is nents in the signal. This simple fact tells us that apart from the formal demand on the
fitted inside the sounder. Recommended tone: No. 7, continuous at 950 Hz, 103 dBA, whistle - having a sufficiently strong component within one 1/3 octave band (IMO
12 mA. regulations) - there are other important factors too. The MKT-75/800 Typhoon have
an effecient sound spectrum fulfilling the highest demands - on vessels as well as in a
great many civil defence and disaster alarm stations on land.
N1525 006312
DB3V02BR, alarm Siren/bell, Ex-proof, 24 VDC Multitone sound disc, mounted below UB-6
DB3V is a lightweight, flameproof sounder intended for use in potentially explosive Salwico 4800 fire alarm annunciator is specially made to fit between the UB-1 or
atmospheres. DB3 has been designed with high ingress protection to withstand harsh B-2 fire detector base and the ceiling. The annunciator is 24 Vdc powered from the
environmental conditions. The flame paths, flare and body are manufactured com- central or from a local control unit like CM22 or CM44. Salwico 4800 provides
pletely from UV stable glass reinforced polyester. Stainless steel screws and sinter are acoustical alarms either in case dedicated annunciators are to be fitted for the fire
incorporated thus ensuring a corrosion free product. DB3V has a pre-programmed alarm system, or when it is required to have a local annunciator which completes the
bell-tone and integral volume control. DB3V is delivered without cable glands. DB3 existing PA/GA alarm system. Salwico 4800 contains an electronic sound generator
fulfils the following requirements: which allows to choose between 2 different tones, which complies with the various
Eexde IIC T5 ATEX, Ex II 2GD BASEEFA certified standards in use worldwide. By feeding the Salwico 4800 through a third wire, it is
DB3V is also available in GOST R & K, Chinese (CQST), Australian (SAA) and UL possible to activate an alternative sound to the one programmed, in way to get two
models. different alarm tones, depending on the case.Volume adjustment is possible by an
006255 005303
internal control, in order to set the desired sound pressure.
34 35
Salwico Fire Detection System Salwico Fire Detection System
Lights
830, flash light, red, 230VAC, IP65 828, flash light, green, 24VDC, IP65
Salwico 830 is a flash light suitable for installation in harsh environments. Salwico 830 Salwico 828 is a modern designed flashlight suitable for installation in harsh environ-
is easy to install and has a long life time. Wall brackets and other colours on the lens ments. Salwico 828 is easy to install and has a long lifetime. Tools are required to dis-
and are available upon request. mount the lens, which prevents sabotage. For installation on walls, use the separate
wall bracket part number 6514.
006502 5200073-00A
BE-24, flash light, red, 24VDC, dry space. FLASH/NI, Sounder & beacon, 32 tones, IP65
The BE-24 is an electronic flash light with low power consumption. It has small di- Flashni is a compact combination of a high output sounder and beacon for spaces
mensions and is easy to install. The flash light is polarity dependent and will not work requiring both audible and visual indication of alarms. The ingress protection IP65
if polarity is switched. makes it suitable for installation in harsh environment. The sounder can be set to 32
different tones. The tones are set with a DIP switch inside the unit. It is also equipped
with a volume control.
N1541 N1546
006512 007112
36 37
Salwico Fire Detection System Salwico Fire Detection System
Calectro UG-3-O (for DOS3), vent. duct adapter excl. tube and head
NS-DRP, Door Release, wall mounted WT, IP-55
UG-3 has been developed to detect smoke in ventilation ducts and combines a
This door release switch is made for harsh environments that requires ingress smoke detector and an adapter system, where both tube and housing are specially
protection up to IP55. The switch is not spring loaded. Therefore it will stay in closed designed for optimum airflow through the smoke detector. The system meets all
position until it is manually set to open position. the requirements for safe fire detection with airflow speeds from 0.2 m/s to 20 m/s.
Since the UG-3 is used with different types of fire alarm systems and installations it
is delivered without: Venturi pipe Detector
The UG-3 is made for rectangular ducts. The optional UG-MB Mounting bracket has
to be used if the UG-3 should be mounted on insulated or circular ducts. A test hole
on the UG-3 cover makes it easy to test the smoke detector. Simply remove the
plastic plug and spray test gas into the UG-3.
N1781 5200239-00A
Calectro Pipe
NS-DRW, Fire Door Release Button, wall mounting
Part no: 5200225-00A Calectro VR-0.6M Pipe, for ducts <600 mm
This door release switch is made for wall mounting in dry areas where recessed
Part no: 5200226-00A Calectro VR-1.5M Pipe, for ducts <1500 mm
mounting is not possible. The switch is not spring loaded. Therefore it will stay in
Part no: 5200227-00A Calectro VR-2.8M Pipe, for ducts <2800 mm
closed position until it is manually set to open position.
5200225-00A
5200226-00A
N1779
5200227-00A
N1780 5200229-00A
38 39
3
Salwico Gas Detection System Salwico Gas Detection System
Standard Centrals
Salwico GDS
This Gas detection system is a state-of-the-art addressable detection system de-
signed to meet marine, industrial and transport requirements. Special care is given to
ergonomics and user-friendliness with its logical and intuitive operator panel. These
standard centrals are designed for small stationary gas detection installations for the
monitoring of explosive and/or toxic gases. Salwico Gas Detection System is SOLAS
compliant and certified by all major classification societies for marine applications.
The Salwico Gas Detection System can also accomondate larger gas detection installations on request such as LNG
System vessel, FPSO:s, Drillships etc. These systems will be tailor made for its application.
40 41
Salwico Gas Detection System Salwico Gas Detection System
Buscon M Gas
Bus Isolator M
The BusCon M Gas is a connection module for the Salwico Gas Detection System.
This module provides electric isolation for the system and backbone extension for Bus Isolator M divides the system backbone businto segments. Its dual functional-
module Control M Gas, as well as monitors the supply voltage and the Xgas signal. ity isolates communications and basic backup signals between the stretched system
The BusCon M Gas has a 20-pin flat cable connector with extended BBI interface for parts and provides power to
connection with a Control M Gas module. the control panel (e.g. Control M Gas).
5103002-00A 5100071-01A
Analogue M 4-20
Relay M 8
The Analogue M 4-20 is a transmitter module for a gas alarm system. This module
provides four transmitter interfaces (4-20 mA inputs): Relay M 8 provides eight programmable relay
2-wire 3-wire, current source 3-wire, current sink 4-wire contacts. Each of these relay contacts provide a potential free change-over contact.
In order to avoid a massive start-up current in the system the Analogue M 4-20 mod- Use Relay M 8 to control units such as sirens, magnets, flashlight, alarms and ventila-
ule delays the voltage output (+, SG) in the ransmitter interfaces upon start-up: tion fans.
Transmitter interface 1, 0 10 ms
Transmitter interface 2, 125 10 ms
Transmitter interface 3, 250 10 ms
Transmitter interface 4, 375 10 ms
5103003-00A 5100081-01A
The Power Boost M is designed to distribute power and supervise connections in a PSU M AC/DC 5A is a miren apporved power supplu that powers the system. It is
gas alarm system. Features This module can supply: Centralized power through a shortcircuit proof and can be used in pairs to supply 5+5 A or 48VDC.
Power Boost Loop, which is secured against interruption and short circuit. Com-
pensation for voltage drop in the cable for distributed modules in gas alarm systems
Transfer of xGas status between the Power Boost modules on a Power Boost Loop
and the system modules connected to the Power Boost module on the internal
Backbone Bus (BBI) External Backbone Bus (BBE) PB-485 communication between
system modules. Protection of the External Backbone Bus (BBE) PB-485 commu-
nication between modules against interruptions and short circuits. Supervise the
5103004-00A 48 VDC and the PbxGas signals (on the Power Boost Loop). Transform External 5100087-01A
Backbone Bus (BBE) PB-485 to Internal Backbone Bus (BBI) RS-485.
42 43
Salwico Gas Detection System Salwico Gas Detection System
Control/Repeater Panels Gas Detecors
Control M Gas External SALWICO GD
The Control M Gas is a control panel with a 4.3 graphical colour display used to The Salwico GD range of gas detectors is used to monitor areas where flammable,
manage and supervise a gas alarm system either as a external control or repeater oxygen deficiency and toxic gases may pose a hazard environment. The Salwico GD
panel. Control M Gas External can be mounted on any flat surface or flush mounted, uses a number of sensor technologies including catalytic bead, electrochemical cell
independently from a gas alarm cabinet. Control M Gas External is equipped with and Non-dispersed (NDIR). Salwico GD has a long list of user friendly features:
communication buses for connecting to the system via BBE interface RS-485 or BBE One hand operation for sensor replacement
interface PB-485. Features: A backlit 4.3 graphical colour display Alarm buzzer Clear multi-function backlit display
LED status indicators Backbone Bus Interface RS-485 Backbone Bus Interface Tri-colour backlight display for status indication
PB-485 (Power Boost loop) USB interface (for service & maintenance) Two 4-20 mA signal output
configurable inputs Three programmable outputs 3 Switch relays
5103001-00A Modbus
EX-d approved
Log Printer
The Salwico GD range gas detectors are available in the following variants.
Serial Printer Epson LX300+II
5200260-01A Salwico GD CAT HC 0-100%LEL HYDROCARBON, CATALYTIC, ALUMINIUM AL-
Because of its compact dimensions, the Epson LX-300+II is the ideal 9-pin printer for LOY, M20 ENTRY
applications where space is limited and also a low cost solution for measurement and 5200260-02A Salwico GD NDIR CH4 0-100%LEL METHANE, NDIR, ALUMINIUM ALLOY; M20
control systems. With auto switching USB, serial and parallel interfaces the LX-300+II ENTRY
privide flexible standalone connectivity.
5200260-03A Salwico GD NDIR C3H8 0-100%LEL PROPANE, NDIR, ALUMINIUM ALLOY, M20
ENTRY
5200260-04A Salwico GD NDIR CO2 0-2%VOL CARBON DIOXIDE, NDIR, ALUMINIUM ALLOY,
M20 ENTRY
44 45
Salwico Gas Detection System Salwico Gas Detection System
46 47
Salwico Gas Detection System Salwico Gas Detection System
Alarm Devices
NS-ES, electronic siren, 24VDC, IP54, red.
KTV-75/400 typhoon 230 VAC, 400Hz
The NS-ES is a Roshni LP sounder that can be connected to all Salwico safety sys-
tems. It has a range of 32 tones which is set by a DIP switch. It is also equipped with The pneumatic alarm typhoons in the KTV and MKTV series are a maintenance free,
a volume control. The NS-ES is pre-set to tone no. 14 (970 Hz, 105 dBA (+/- 2 dBA) light, rigid and powerful signalling apparatus for different applications onboard ships.
at 1 m). A second tone is available, which can be switched in by the connection of a The typhoons can be delivered as a complete unit or the horn and the solenoid valve
third core to the siren.Volume control switch The switch will provide two settings, as separate units (see separate datasheet). For distinct signals, the piping length be-
either full output or an attenuation of 10dB. tween the valve and the horn should not exceed 6m. The horn is delivered with wall
bracket and filter. For explosive, corrosive or very hot areas the solenoid valves shall
be mounted separately outside the exposed area. The solenoid valve is delivered with
filter and fittings for copper piping with 10 mm OD. The solenoid valve should not
N1535 6304 be placed outdoor without protective cover.
NS-ES, electronic siren, 24VDC, IP66, red. MKT-75/400 Typhoon without mag.valv. 400Hz
The NS-ES/IP66 is a low profile Banshee MT siren for all Salwico Safety systems for The pneumatic alarm typhoons in the KTV and MKTV series are a maintenance free,
installation in harsh enviromants (IP66). The siren is delivered with cable glands for light, rigid and powerful signalling apparatus for different applications onboard ships.
cable diameters raging from 8 to 13mm. The base has two knockout holes for the The typhoons can be delivered as a complete unit or the horn and the solenoid valve
cable glands. A sounder selector for user selectable tones and a volume control is as separate units (see separate datasheet). For distinct signals, the piping length be-
fitted inside the sounder. tween the valve and the horn should not exceed 6m. The horn is delivered with wall
bracket and filter. For explosive, corrosive or very hot areas the solenoid valves shall
be mounted separately outside the exposed area. The solenoid valve is delivered with
filter and fittings for copper piping with 10 mm OD. The solenoid valve should not
be placed outdoor without protective cover.
N1525 6311
DB3V is a lightweight, flameproof sounder intended for use in potentially explosive Soleniod valve for 6311 MKT-75/400 Typhoon without mag.Valv. 400Hz
atmospheres. DB3 has been designed with high ingress protection to withstand harsh
environmental conditions. The flame paths, flare and body are manufactured com-
pletely from UV stable glass reinforced polyester. Stainless steel screws and sinter are
incorporated thus ensuring a corrosion free product. DB3V has a pre-programmed
bell-tone and integral volume control. DB3V is delivered without cable glands. DB3
fulfils the following requirements: Eexde IIC T5 ATEX, Ex II 2GD BASEEFA
certified. DB3V is also available in GOST R & K, Chinese (CQST), Australian
(SAA) and UL models.
6255 6318
The pneumatic alarm typhoons in the KTV and MKTV series are a maintenance free, Soleniod valve for 6311 MKT-75/400 Typhoon without mag.Valv. 400Hz
light, rigid and powerful signalling apparatus for different applications onboard
ships. The typhoons can be delivered as a complete unit or the horn and the solenoid
valve as separate units (see separate datasheet). For distinct signals, the piping
length between the valve and the horn should not exceed 6m. The horn is delivered
with wall bracket and filter. For explosive, corrosive or very hot areas the solenoid
valves shall be mounted separately outside the exposed area. The solenoid valve is
delivered with filter and fittings for copper piping with 10 mm OD. The solenoid
valve should not be placed outdoor without protective cover.
6303 6330
48 49
Salwico Gas Detection System Salwico Gas Detection System
SUE-9412A-1, flash light, 230VAC, Eexd IIBT4 X-AM2000-HC,LEL-H2S Portable Gas Detector
The SUE9412A-1 is a serie of EX classified flash lights designed for use in very harsh The Drger X-am 2000 is one of a new generation of gas detectors which have
environments, for example pump rooms on vessels. SUE9412A-1 is available in the been specially designed for personal monitoring use. The 1- to 4-gas detector
following models: reliably measures combustible gases and vapours, as well as O2, CO and H2S. Its
Art.no Power supply Colour on lens ergonomic design, mobile phone dimensions and low weight make it the perfect
Part no: 6543 230VAC Blue companion in your daily work. Reliable measurement technology, long sensor life
Part no: 6545 230VAC Red and easy operation guarantee maximum safety at extremely low cost of ownership.
Part no: 6547 230VAC Yellow
Part no: 6548 115VAC Yellow
Part no: 6549 230VAC Orange 4582
Horn w. Red Rot. Light 230V Exd IIC T6 X-AM2000-HC,LEL-O2-H2S Portable Gas Detector
Electric horn with red rotating light for harsh enviroments, Exd IIC T6 The Drger X-am 2000 is one of a new generation of gas detectors which have
been specially designed for personal monitoring use. The 1- to 4-gas detector
reliably measures combustible gases and vapours, as well as O2, CO and H2S. Its
ergonomic design, mobile phone dimensions and low weight make it the perfect
companion in your daily work. Reliable measurement technology, long sensor life
and easy operation guarantee maximum safety at extremely low cost of ownership.
5200117-00A 4583
4580 4584
4581 4585
50 51
Salwico Gas Detection System Salwico Gas Detection System
Calibration Parts
CALIBRATION KIT, REG+FH
X-AM2000/5000 Chargeable batteries
Calibration kit for all Salwico Gas Detectors. Parts included in the kit is:
Chargeable batteries for portable gas detectors of the type A-AM2000/5000 series
1 x Regulator for the gas bottle
2m of tubing for connetion between gas bottle and detector
1 x Flow house for ST-type detectors
4586 5201013-00A
4594 5201000-10A
5200049-00A 5201010-10A
4220 5201004-00A
52 53
Salwico Gas Detection System Salwico Gas Detection System
CO2 Calibration Gas Bottle, CO2+oxygen 5000 ppm N2 Calibration Gas Bottle, N2 100% Vol.
Sawico GDS standard disposable calibration gas bottles. Should together with Sawico GDS standard disposable calibration gas bottles. Should together with
5201013-00A when calibrating any of the Salwico Gas Detectors. 5201013-00A when calibrating any of the Salwico Gas Detectors.
5201006-00A
5201003-00A Moore calibration gas bottleas with different mixtures are avalible on request
Suitable locations:
Water ballast tanks Non accessible areas
5201005-00A Isolation spaces on LNG vessels
54 55
Salwico Monitoring System Salwico Monitoring System
Salwico Emission Monitoring System
M1040/SeaNox Analyser 220 VAC
The Salwico NOx analyser is a well-proven chemiluminescent Compact NOx Analys-
er with an integrated dilution that fully complies to Marpol Annex IV NOx Technical
Code. The Salwico NOx analyser is specially designed for operation in continuous
emissions monitoring application with clean gas system and process control of De-
NOx system. The analyser is a complete, fully integrated monitoring system, config-
ured and tested according to the requirements for each application.
Easy menu drive operation, easy service and maintenance as well as a variety of built-
in self checks and alarm features assures for a secure and reliable analyser.
550011
550040
550045
56 57
Salwico Monitoring System Salwico Monitoring System
550030 550070
550160
550060 550140
58 59
Salwico Monitoring System Salwico Monitoring System
DP79100 dilution probe (one for each measuring point) BM100 Pressure sensor (ambient)
The Salwico DP7900 is a dilution probe to be used together with Salwico NOx and The BM 100 sensor is used for recording the ambient air pressure. The range is 0.7 -
SO2 compact gas analyser system. The DP7900 is with its uniformly heated dilution 1.1 bar and it gives a 4-20mA signal.
block - particularly well suited for use in connection with wet scrubbers and other
applications where the stack gas is wet or has a temperature below acid and/or wa-
ter dewpoint. Accuracy of measurement is superior compared to other systems due
to the fact that no component of the sample will disappear as a result of condensa-
tion. The dilution probe is easy mounted for easy dismantling for filter checks and
replacement The Salwico DP7900 can be used in high temperature enviroments up
550170 to 1800C. 550120
550380 550090
Probeflange gasket for 550380 DN50 PN10 Packing for vacuum pump Filter Media for fan, SK3170 Discharge plate for Ozone
generator O-ring for Ozone generator Zero Air Scrubber.
550382
550200
550110 550220
60 61
Salwico Monitoring System Salwico Monitoring System
550260 550647-00A
550180 6731003-00A
Spare part kit for Salwico (SeaNox/SeaSox) 1 year Salwico G1000 Smoke Density Monitor 110VAC
Membrane set for Dual Chamber pump Filter media for Fan , SK3170 Zero Air The G1000 is a particular robust system well suited to resist heat and vibrations in
Scrubber. and around smoke stacks. The patented technology do not locate the light source
inside the smoke stack, instead, the infrared LED is placed in the monitor cabinet
and the light beam brought to the smoke stack via robust optic fibres. The lenses of
the optic heads are kept clean with purge air. Quite evidently, this method reduces
maintenance and need of spare parts to a bare minimum. This invention was the first
to make use of this design, sincerely appreciated by our customers.
550230 6731004-00A
Spare part kit for Guardian CO2 Salwico G1000 Smoke Density Monitor 24VDC
Filter membrane. The G1000 is a particular robust system well suited to resist heat and vibrations in
and around smoke stacks. The patented technology do not locate the light source
inside the smoke stack, instead, the infrared LED is placed in the monitor cabinet
and the light beam brought to the smoke stack via robust optic fibres. The lenses of
the optic heads are kept clean with purge air. Quite evidently, this method reduces
maintenance and need of spare parts to a bare minimum. This invention was the first
to make use of this design, sincerely appreciated by our customers.
550652 6731005-00A
62 63
Salwico Monitoring System Salwico Monitoring System
6731011-00A 6731023-00A
Fiber optic cable L=7.5 m T<240C Audit Pen 30% Opacity for calibration.
6731014-00A 6700059-00A
6731021-00A 6731019-00A
64 65
Salwico Monitoring System Salwico Monitoring System
Salwico G2000 Ambient Oil Mist Detector 110VAC Optical Fibers 1x4.5m & 1x6.0m
The G2000 Ambient Oil Mist Detector is developed for monitoring pump rooms, Fiber optic cable L=4.5 m T<240C Fiber optic cable L=6.0 m - T<240C.
engine- and motor rooms and attached onto boilers or diesel engines. The perils of
oil mist and the potential impacts thereof, is clearly stated by IMO and OCIMFs Ship
Inspection Report (SIRE) Programme. Thus, early alarms on the formation of oil mist
are utterly important. A minor investment yields great benefits, not the least appreci-
ated by vetting inspectors. The G2000 is ideal for applications where an instantane-
ous and accurate response to oil mist, but also smoke or steam, is required in unat-
tended machinery spaces. The G2000 is a Line-Of-Sight opacity meter; aka; Beam- 6732013-00A
or Open Path- Detector The Line-Of-Sight principle has the decisive advantage of
6732004-00A
covering a larger area than single-point extractive- sampling systems.
Salwico G2000 Ambient Oil Mist Detector 24VDC Optical Fibers 2x7.5m
The G2000 Ambient Oil Mist Detector is developed for monitoring pump rooms, Fiber optic cable L=7.5 m T<240C.
engine- and motor rooms and attached onto boilers or diesel engines. The perils of
oil mist and the potential impacts thereof, is clearly stated by IMO and OCIMFs Ship
Inspection Report (SIRE) Programme. Thus, early alarms on the formation of oil mist
are utterly important. A minor investment yields great benefits, not the least appreci-
ated by vetting inspectors. The G2000 is ideal for applications where an instantane-
ous and accurate response to oil mist, but also smoke or steam, is required in unat-
tended machinery spaces. The G2000 is a Line-Of-Sight opacity meter; aka; Beam-
or Open Path- Detector The Line-Of-Sight principle has the decisive advantage of
6732005-00A covering a larger area than single-point extractive- sampling systems. 6732014-00A
6701140-00A 6732023-00A
66 67
You find us worldwide
Stockholm
Gothenburg
Oslo
Rotterdam
Zeebrugge
Newcastle Helsinki
Glasgow
Rochester Hamburg
Pusan
Dammam
Dalian
Houston
Long Beach Barcelona Piraeus Doha Mumbai Qingdao Tokyo
Bilbao
New York Vishakhapatnam Shanghai
Ft Lauderdale Hong Kong
Naples
Florence Hanoi
Genua
Cochin Ho Chi Minh
Abu Dhabi
Dubai
Oman
Singapore
Consilium Offices
Sales & Service Representatives
www.consilium.se
2012-3
Sensepoint XCD
One-Stop Shop
Flammable (catalytic or infrared), toxic and
The Sensepoint XCD range provides
Oxygen versions available
New and retrofit applications
comprehensive monitoring of flammable,
Suitable for indoor or outdoor use
Stainless steel or aluminium toxic and Oxygen gas hazards in potentially
explosion-proof housing options
IP66 as standard explosive atmospheres, both indoors and
Proven and Reliable outdoors. Users can modify detector
Sensor Technology
SurecellTM electrochemical sensors
Poison immune infrared sensors
operation using the LCD and magnet
Poison resistant catalytic bead sensors
Long life sensors
switches without ever needing to open the
Global Approvals unit. This enables one-man, non-intrusive
European, US, Canadian and Asian
Compliant with ATEX, IECEx, UL, cUL, KTL, operation and reduces routine maintenance
PA, GB and CCCF standards
time and costs.
Easy to Use
User friendly and intuitive tri-colour
backlit display with digits, bar graph A tri-colour backlit LCD clearly indicates the Sensepoint XCD has an integral mounting plate
and icons units status at a glance, even from a distance. for surface mounting or can be mounted to a
Fully configurable via magnetic switches A steady green backlight indicates normal horizontal or vertical pipe using the optional
Optional remote sensor mounting* operation, flashing yellow indicates fault and pipe mounting bracket. Electrical installation
Selectable sink or source 4-20mA output flashing red indicates an alarm. can be made using either conduit or cable
Auto-inhibit during maintenance
with suitable mechanical protection. Two M20
MODBUS communications for remote All detectors are supplied pre-configured or NPT entries are provided (depending
diagnostics/configuration* and include 2 programmable alarm relays, on certification). A weatherproof cap is also
1 programmable fault relay as well as an
Cost Effective industry standard 4-20mA output (sink or
included for use in the harshest outdoor
Common transmitter platform conditions. Other optional accessories include
Minimal training required source selectable) and MODBUS*. a sunshade/deluge protection, duct mounting
Reduced spares The scale, range, relay operation, alarm set kit, collecting cone and remote mounting
Non-intrusive, one-man operation point and electronic tag number of the detector sensor socket*.
Plug-in sensor replacement can be adjusted using the transmitter's LCD
MODBUS multi drop option offers Sensepoint XCD ensures easy installation
and non-intrusive magnetic switches. Outputs and the fastest routine operation by removing
cabling savings*
are automatically inhibited during adjustment, the need for hot work permits in hazardous
Simple Installation thereby reducing the risk of false alarm at the areas. Using easy to replace plug-in sensors,
Plug-in display module removes to give access control panel during maintenance. downtime is also reduced and on-going costs
to terminal area are minimised through the use of poison
Integral mounting bracket resistant flammable sensors, poison immune
2 x M20 or NPT cable/conduit entries
infrared Hydrocarbon sensors and patented
(certification dependent)
Removable plug/socket type terminal blocks for Surecell toxic sensors.
ease of wiring
Sink/source switch to suit preferred wiring 8.
11.
topology 5.
4.
Range of Optional Accessories
Remote sensor mounting kit*
Remote sensor gassing kit 10.
Duct mounting kit
Calibration gas flow housing 3.
Collecting cone 2.
*Contact Honeywell Analytics for availability of these options. 1.
1. Cover
2. Display module
6. 3. Terminal area
4. Blanking plug
5. Transmitter
Typical Applications 6. Plug-in XCD sensor
Industrial manufacturing facilities Refineries and chemical plants 7.
Power plants Onshore oil and gas terminals 7. Sensor retaining ring
Waste water facilities Production platforms 8. Integral mounting plate
Utilities Exploration and drilling 9. Weather protection assembly
Food and beverage production 9. 10. Cable/conduit entry (x2)
11. Certification label
Sensepoint XCD Overview
mV
for detection of Hydrocarbon gases in the Sensor Family Methane 20 to 100%LEL 100%LEL 10%LEL 50%LEL
range 0-100%LEL and 0-100%Vol*, as well as Methane 20 to 100%Vol.* 100%Vol. 10%Vol. 50%Vol.
30 to 70% of selected
Carbon Dioxide (CO2) in the range 0-2%Vol. Carbon Dioxide 2.00%Vol. only 2.00%Vol. n/a full scale range 1.00%Vol.
The EC type transmitter is for use with Electrochemical Sensors
the EC family of XCD sensors including Hydrogen Sulphide 10.0 to 100.0ppm 50.0ppm 0.1ppm 25ppm
EC
IR Methane %Vol*
EC H2S
EC CO
EC H2
EC O2
The Sensepoint XCD transmitter has an integral mounting plate consisting of four mounting holes
on the transmitter body. The transmitter may be fixed directly to a surface mounting, or to a
horizontal or vertical pipe/structure, 40.0-80.0mm (1.6 to 3.1") in diameter/cross section.
The pipe mounting bracket accessory (optional) may be used for this purpose.
User cable entries shown (2 x M20) are for ATEX/IECEx version enclosures. UL/cUL versions
have 2 x "NPT conduit entries. A suitable blanking plug is supplied which must be used to
seal any unused entry. The blanking plug must be suitably sealed to maintain the IP rating of
the detector.
Wall Mounted
8.5 80 12
106
225
164 99
Other Accessories
Sensepoint XCD is designed for use in potentially explosive atmospheres. As such, installation The Sensepoint XCD transmitter may be
should follow national guidelines using suitable mechanically protected cable and glands or wired in either Current Sink or Current
conduit. Use 0.5mm2 (20AWG) to 2.5mm2 (~13AWG) cross sectional area cable as needed to Source configuration. These two options
ensure minimum operating voltage at the detector, depending on installed cable length. are offered to allow greater flexibility in
Cable diameter should be selected to maintain the minimum required voltage for the longest the type of control system that it can be
installed cable length under maximum power. used with. Sink/Source is selectable via
the switch located on the back side of the
display module; accessible by removing
Terminal Module Connections the display module during installation/
Terminal Number Marking Connection Description commissioning.
24V NC 7
1 -VE -VE
2 0V RLY1 COM 8 3 2
4~20mA NO 9
3
COM NC 10
4 RLY2
TxD Digital COM 11
5 Comm
RxD NO 12
6
NC 13 XCD Sink Configuration
RLY3 COM 14
NO 15 SINK
Note: Terminate cable screen at the
SOURCE
4-20mA MODE detector or the controller, not both.
Note: Table given for guidance only. Users should calculate maximum distances using actual
data for cable being used. Typical calculation assumes minimum guaranteed controller supply
of 24VDC, minimum detector voltage of 16VDC and maximum power supply under full alarm.
RL (max) is 250ohms.
Technical Summary
Construction
Material Housing Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor 316 stainless steel
Weather Protection Plastic
Weight (approx) Aluminium Alloy LM25 2.0kg (4.4lbs)
316 Stainless Steel 5.0kg (11lbs)
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts
Optional pipe mounting kit for horizontal or vertical pipe 1.5 to 3" (2" nominal)
Entries European ATEX/IECEx versions: 2 x M20 cable entries
North American UL\cUL versions: 2 x "NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating
Detectable Gases and XCD Sensor Performance
Gas User Selectable Default Steps User Selectable Default Cal Response Accuracy Operating Temperature* Default Alarm Points
Full Scale Range Range Cal Gas Range Point Time (T90)
Secs Min Max A1 A2
Electrochemical Sensors
Oxygen 25.0%Vol. only 25.0%Vol. n/a 20.9%Vol. (Fixed) 20.9%Vol. <30 <+/-0.5%Vol. -20C / -4F 55C / 131F 19.5%Vol. 23.5%Vol.
Hydrogen Sulphide 10.0 to 100.0ppm 50.0ppm 1ppm 25ppm <50 <+/-1ppm -20C / -4F 55C / 131F 10ppm 20ppm
Carbon Monoxide 100 to 1,000ppm 300ppm 100ppm 100ppm <30 <+/-6ppm -20C / -4F 55C / 131F 100ppm 200ppm
Hydrogen 1,000ppm only 1,000ppm n/a 500ppm <65 <+/-25ppm -20C / -4F 55C / 131F 200ppm 400ppm
Methane 20 to 100%LEL 100%LEL 10%LEL 50%LEL <40 <+/-1.5%LEL -20C / -4F 50C / 122F 20%LEL 40%LEL
Methane* 20 to 100%Vol. 100%Vol. 10%Vol. 50%Vol. <40 <+/-1%Vol. -20C / -4F 50C / 122F 20%Vol. 40%Vol.
Carbon Dioxide 2.00%Vol. 2.00%Vol. n/a 1.00%Vol. <40 <+/-0.04%Vol. -20C / -4F 50C / 122F 0.40%Vol. 0.80%Vol.
Certification*
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40C to +65C) Ex tb IIIC T85C Db IP66
International IEC Ex II 2 GD Ex d IIC Gb T6 (Ta -40C to +65C) Ex tb IIIC T85C Db IP66
China GB Ex d IIC T4 GB3836.1&2 -2000, PA, CCCF
Korea KTL Ex d IIC T6 (-40C to +65C)
US and Canada UL/cUL Class 1, Div 1, groups B,C,D
EMC CE: EN50270:2006 EN6100-6-4:2007
Performance ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271
China: PA Pattern Measurement (for transmitter and toxic gas sensors)
CCCF Shenyang for Flammable (fire dept approval)
UL508
Environmental
Standard Supply Sensepoint XCD is supplied complete with integral wall mounting plate, 2 x M20 cable entry (ATEX/IECEx) or 2 x NPT conduit entries (UL/cUL),
1 x M20 or 1 x NPT plug, Allen key for locking screw, weatherproof cap, operating magnet, sensor cartridge with retainer, quick start guide and instruction
manual CD. Default settings, ranges and calibrations are 100% tested at the factory. Each unit is supplied with a calibration and test certificate.
Shipping Details Shipping carton dimensions: L312mm (12.3) x W223mm (8.8) x D110mm (4.3) Approximate weight: Aluminium 2.5kg (5.5lbs), Stainless Steel 5.5kg (12.1lbs)
Enclosure Material
L- LM25 Sensor Type
*For UL/CSA versions simply change the letters in the part number for certification and entry e.g. first part number in table above would become SPXCDULNFX.
**For further explanation refer to "Detectable Gases and XCD Sensor Performance" table on page 6.
Our Product Range
Holder of Certificate
Honeywell Life Safety AS
DRAMMEN, Norway
Application
Location classes:
Temperature A
Humidity B
Vibration A
EMC B
Enclosure Delta OP and Delta Compact: Class A, Delta DA and Delta DA Esser:
Required protection according to the rules to be provided upon
installation on board.
Odd Magne Nesvg DNV local office: Guri Birgitte Lberg Nerhus
Head of Section Oslo Surveyor
This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid.
The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Hvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com
Form No.: 20.100a Issue: October 2009 Page 1 of 4
Certificate No.: A-12626
File No.: 473.11
Job Id.: 262.1-002449-3
Product description
The DELTA system incorporates the following main units:
Manufactured by
Honeywell Life Safety Romania S.R.L.
Lugoj, 2 bis Salcamilor Str., Timis Conunty, Romania
Responsibility
The Holder of Certificate takes the responsibility that both design and production are in compliance with the Rules and
standards listed on page 1 and 2 of this Type Approval Certificate
Application/Limitation
System configuration and application are to be in accordance with relevant parts of the Rules.
Approval Conditions
The Type Approval covers hardware and software listed under Product description.
The following documentation of the actual application is to be submitted for approval in each case:
- Reference to this Type Approval Certificate
- System block diagram
- Power supply arrangement (may be part of the System block diagram)
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Hvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com
Form No.: 20.100a Issue: October 2009 Page 2 of 4
Certificate No.: A-12626
File No.: 473.11
Job Id.: 262.1-002449-3
As long as the units are covered by the Type Approval, no Product certificate will be required according to Pt.4 Ch.9 Sec.1 A
202.
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Hvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com
Form No.: 20.100a Issue: October 2009 Page 3 of 4
Certificate No.: A-12626
File No.: 473.11
Job Id.: 262.1-002449-3
END OF CERTIFICATE
DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Hvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com
Form No.: 20.100a Issue: October 2009 Page 4 of 4
5
FIRE DETECTION AND
ALARM SYSTEMS
Theunissen Technical Trading BV Postbus 70 6580 AB Malden Holland Tel. +31 (0)24-3584455 Fax. +31 (0)24-3582166 www.tttbv.nl
Shipyard Country Hull no. Vessel name Vessel type
Rauma-Repola Oy - Pori Finland 9 Safe Hibernia Accommodation Platform, semi subm.
Simek Flekkefjord Norway 107 Lady Astrid Anchor Handling Tug Supply
Maclaren Rio De Janeiro Brazil 237 DP Geo Anchor Handling Tug Supply
Dalian Shipyard Co Ltd - Dalian LN China AH23-1 Sudaksha Anchor Handling Tug Supply
Dalian Shipyard Co Ltd - Dalian LN China AH23-2 Subhiksha Anchor Handling Tug Supply
Tebma Shipyards Ltd India 123 Anchor Handling Tug Supply
Tebma Shipyards Ltd India 124 Anchor Handling Tug Supply
Pan-United Shipyard Batam Indonesia 163 Pacific Rapier Anchor Handling Tug Supply
Pan-United Shipyard Batam Indonesia 164 Pacific Responder Anchor Handling Tug Supply
Aker Yards Brevik Norway 42 Far Sword Anchor Handling Tug Supply
Aker Yards Brevik Norway 43 Far Strait Anchor Handling Tug Supply
Aker Yards Brevik Norway 44 Far Sound Anchor Handling Tug Supply
Aker Yards Brevik Norway 56 Far Sabre Anchor Handling Tug Supply
Aker Yards Langsten Norway 188 Maersk Handler Anchor Handling Tug Supply
Aker Yards Langsten Norway 189 Maersk Helper Anchor Handling Tug Supply
Aker Yards Langsten Norway 212 Far Sapphire Anchor Handling Tug Supply
Flekkefjord Slip & Maskinfabrikk AS Norway 186 Anchor Handling Tug Supply
Simek Flekkefjord Norway 105 Lady Caroline Anchor Handling Tug Supply
Shanghai Waigaoqiao Shipbuilding China 1008 Teh May Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1009 An May Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1019 Ocean Confidence Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1020 China Peace Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1024 Anangel Prosperity Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1025 China Progress Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1026 Sideris GS Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1027 CHS Creation Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1029 CHS World Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1030 CHS Cosmos Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1033 Harmonious Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1035 Semirio Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1036 Mineral Capeasia Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1039 China Venture Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1040 Ventura Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1041 Voge Master Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1045 Pompano Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1046 Fernandina Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1013 Mineral Tiajnin Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1014 Mineral Belguim Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1028 Mineral Hong Kong Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1031 Anangel Fortune Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1032 Cape Shanghai Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1034 Heng Shan Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1037 Ocean Cresent Bulk Carrier
Shanghai Waigaoqiao Shipbuilding China 1038 Ocean Commander Bulk Carrier
Retrofit Splittnes Bulk/self discharge
Ulstein Verft Norway 259 Oceanic King Cabel laying vessel
Kanrei Zosen K.K. - Naruto Japan 388 Geowave Master Cable Layer
Aker Yards Sviknes Norway 130 Geo Challenger Cable Layer
Flekkefjord Slip & Maskinfabrikk AS Norway 154 Oceanic Viking Cable Layer
Aker Yards Aukra Norway 114 Nina Chemical Tanker
Celik Tekne Shipyard A.S Turkey 28 M/T Pyla Chemical Tanker
2 (8)
Theunissen Technical Trading BV Postbus 70 6580 AB Malden Holland Tel. +31 (0)24-3584455 Fax. +31 (0)24-3582166 www.tttbv.nl
Shipyard Country Hull no. Vessel name Vessel type
Yardimci Gemi Insaa A.S. Turkey 25 FS Diane Chemical Tanker
Yardimci Gemi Insaa A.S. Turkey 26 FS Mila Chemical Tanker
Yardimci Gemi Insaa A.S. Turkey 31 FS Maud Chemical Tanker
Yardimci Tersanesi A.S. - Tuzla Turkey 30 Panam Serena Chemical Tanker
Qingshan Shipyard China 101 Moyra Chemical Tanker
Rabben Mek. Verksted Norway Marlene stervoll Coast guard
Dalian Shipyard Co Ltd - Dalian LN China MC120-3 Nirint Pride Container Ship
J.J. Sietas shipyard Germany 765 S. Queen Container Ship
Sanoyas Hishino Meisho Japan 1114 Navion Scotia Crude Oil Shuttle Tanker
Framnes Mek. Verksted Norway 115 Christian Radich Cruise Sail
Pan-United Shipyard Pte Ltd Singapore 139 Azteca Diving Support Vessel
Aker Yards Aukra Norway 102 Skandi Carla Diving Support Vessel
Stocznia im Komuny Paryskiej - Gdynia Poland B961/04 Kingfisher Diving Support Vessel
Metalships & Docks, S.A. - Vigo Spain 269 Arbol Grande Diving Support Vessel
Kaldnes MV Norway 219 Transocean Searcher Drilling Rig, semi Submersible
Btservice Mandal Norway 26 Vindafjord Express Coastler
OMA Bt Norway 516 Strandafjord Express Coastler
OMA Bt Norway 517 Fjordlys Express Coastler
Westamarin Norway 91 Tjeldy Express Coastler
Kimek Kirkenes Norway 3103 Skalaberg Factory Stern Trawler
Slipen Mek. Verksted AS Norway 65 Paerangi Factory Stern Trawler
Myklebust Mek. V. Norway 26 Brimil Fishery Patrol Vessel
Karstensens Skibsvrft AS Denmark 396 Western Viking III Fishing Vessel
Aarhus Shipyard Denmark Hoyvingur Fishing vessel
Brdrene Langset AS Norway 7 Sjhav Fishing vessel
Brdrene Langset AS Norway 10 Utflesa Fishing vessel
Brdrene Langset AS Norway 6 Ocean Fishing vessel
Fiskerstrand Verft Norway 46 Nordytrl Fishing vessel
Fitjar Mek Verksted Norway 27 Birkeland Fishing vessel
Flekkefjord Slip & Maskinfabrikk AS Norway 177 Monica Fishing vessel
Havyard Eid Norway 56 Fishing vessel
Havyard Eid Norway 59 Olagutt Fishing vessel
Havyard Eid Norway 60 Ben Jr. Fishing vessel
Havyard Eid Norway 62 Sildaskjr Fishing vessel
Karmsund Maritime Norway 19 Fishing vessel
Karmsund Maritime Norway 23 Seigrunn Fishing vessel
O. Ulvan Baatbyggeri AS Norway 424 Ravnfjord Fishing vessel
Porsgrunn Mek Norway 131 Segla Fishing vessel
Porsgrunn Mek. Norway 132 Lise Beate Fishing vessel
Pusnes Mek. Verksted Norway 79 Kirsti Fishing vessel
Rabben Mek. Verksted Norway 103 Harvest Fishing vessel
Sletta Btbygg Norway 90 Birgerson Fishing vessel
Trondheim Verft AS Norway 6 Trnderhav Fishing vessel
UMOE Sterkoder Norway 227 Marcus Fishing vessel
West Contractors AS Norway 16 Krunborg Fishing vessel
West Contractors AS Norway 23 Resolute Fishing vessel
West Contractors AS Norway 26 Chris Andra Fishing vessel
Karstensens Skibsvrft AS Denmark 397 Isafold Fishing Vessel
Fitjar Mek Verksted Norway 14 Heryhav Fishing Vessel
Retrofit Lady Elisabeth Fjord Cruise Vessel
Aker Yards Langsten Norway 194 Bourdon Opale FPSO
Navantia (Izar-Bazan) Spain 305 KNM Fridtjof Nansen Frigate
3 (8)
Theunissen Technical Trading BV Postbus 70 6580 AB Malden Holland Tel. +31 (0)24-3584455 Fax. +31 (0)24-3582166 www.tttbv.nl
Shipyard Country Hull no. Vessel name Vessel type
Navantia (Izar-Bazan) Spain KNM Helge Ingstad Frigate
Navantia (Izar-Bazan) Spain KNM Otto Sverdrup Frigate
Navantia (Izar-Bazan) Spain 306 KNM Roald Amundsen Frigate
Navantia (Izar-Bazan) Spain KNM Thor Heyerdahl Frigate
Alssund Skibsvaerft A/S - Sonderborg Denmark 25 Kanutta General Cargo Ship
Aker MTW Schiffswerft GmbH Germany 136 Jaco Triumph General Cargo Ship
Kroeger Werft GmbH & Co. Werft KG Germany 1520 Frifjord General Cargo Ship
Scheepswerf Bijlsma B.V. - Wartena Holland 661 Sletringen General Cargo Ship
Navol Oltenita Romania 107 Scot Explorer General Cargo Ship
Celik Tekne Shipyard A.S Turkey 16 Denizsan II General Cargo Ship
Marmara Tersanesi - Yarimca Turkey 52 Tuxpan Reef General Cargo Ship
Selah Makina Sanayi ve Ticaret A.S. Turkey 22 MV Hopa General Cargo Ship
Mjellem & Karlsen AS Norway 107 Srysund Landing craft
Mjellem & Karlsen AS Norway 108 Maursund Landing Craft
Mjellem & Karlsen AS Norway 110 Tjeldsund Landing craft
Feadship-Royal Van Lendt Holland 776 M/Y Daybreak Mega Yacht
Delta Marine Seattle USA 160001 Newvida Mega Yacht
Kvrner Mandal Norway KNM Alta Mine Hunter
Kvrner Mandal Norway KNM Glomma Mine Hunter
Kvrner Mandal Norway KNM Hinny Mine Hunter
Kvrner Mandal Norway KNM Karmy Mine Hunter
Kvrner Mandal Norway KNM Mly Mine Hunter
Kvrner Mandal Norway KNM Oksy Mine Hunter
Kvrner Mandal Norway KNM Otra Mine Hunter
Kvrner Mandal Norway KNM Rauma Mine Hunter
Retrofit KNM Vidar Mine Hunter
K.K. Uwajima Zosensho Japan 2012 Geobay Multi Purpose Offshore Vessel
Tebma Shipyards Ltd India 117 Active Dutches Offshore Support Vessel
Tebma Shipyards Ltd India 118 Active Prince Offshore Support Vessel
Tebma Shipyards Ltd India 119 Active Princess Offshore Support Vessel
Tebma Shipyards Ltd India 120 Active King Offshore Support Vessel
Tebma Shipyards Ltd India 121 Active Queen Offshore Support Vessel
Tebma Shipyards Ltd India 127 Offshore Support Vessel
Tebma Shipyards Ltd India 128 Active Emperor Offshore Support Vessel
Tebma Shipyards Ltd India 129 Active Empress Offshore Support Vessel
Flekkefjord Slip & Maskinfabrikk AS Norway 187 Acergy Viking Offshore Support Vessel
Metalships & Docks, S.A. - Vigo Spain 283 Bourbon Oceanteam 101 Offshore Support Vessel
Stocznia Szczecinska im A Warskiego Poland 92 Geofjord Offshore Tug/Supply Ship
Atlantis Shipyard Singapore 1033 Tugen Oil / product tanker
Snorre A Oil plattform drilling rig
Sandnessjoen Slip & Mek. Verksted Norway 33 Norland Palletised Cargo Ship
Hermann Suerken GmbH & Co. KG Germany 370 Nornews Leader Palletised Cargo Ship
Hudong-Zhonghua Shipbuilding China H1260A Mauritius Trochetia Passenger ship
Karstensens Skibsvrft AS Denmark 579 Passenger ship
Wrtsil Turku Shipyard Finland 1251 Queen Of Scandinavia Passenger ship
Seebeckwerft AG - Bremerhaven Germany 1059 King Of Scandinavia Passenger ship
Moen Slipp AS Norway 56 Sderarm Passenger Ship
Moen Slipp AS Norway 60 Sandhamn Passenger Ship
Mly Verft - Eurobt Norway 2 Vegastar Passenger ship
Oceanfast Marine Pty Ltd Australia 18 Bod Passenger/Ro-Ro Ship
Aker Trondelag AS Norway 827 Gann Passenger/Ro-Ro Ship
Akers Mek. Verksted Norway 547 Lofoten Passenger/Ro-Ro ship
4 (8)
Theunissen Technical Trading BV Postbus 70 6580 AB Malden Holland Tel. +31 (0)24-3584455 Fax. +31 (0)24-3582166 www.tttbv.nl
Shipyard Country Hull no. Vessel name Vessel type
Flekkefjord Slip & Maskinfabrikk AS Norway 165 Hidraferja Passenger/Ro-Ro Ship
Kaarbos Mek. Verksted AS Norway 101 Vesterlen Passenger/Ro-Ro ship
Lland Verft AS - Leirvik i Sogn Norway 29 Frdefjord Passenger/Ro-Ro Ship
Aker Yards Langsten Norway 181 Glutra Passenger/Ro-Ro Ship
Baatservice Holding AS Norway 49 Dodekanisos Pride Passenger/Ro-Ro Ship
Fiskerstrand Verft Norway 44 Melshorn Passenger/Ro-Ro Ship
Fiskerstrand Verft Norway 45 Vardehorn Passenger/Ro-Ro Ship
Fiskerstrand Verft Norway 47 Malangen Passenger/Ro-Ro Ship
Fiskerstrand Verft Norway 49 Jggevarre Passenger/Ro-Ro Ship
Fiskerstrand Verft Norway 50 Hlogaland Passenger/Ro-Ro Ship
Hatlo Verksted AS Norway 41 Fusa Passenger/Ro-Ro Ship
Kleven Verft AS - Ulsteinvik Norway 292 Finnmarken Passenger/Ro-Ro Ship
Kaarboverkstedet AS Norway 395 Mysalen Passenger/Ro-Ro Ship
Moen Slipp AS Norway 54 Anholt Passenger/Ro-Ro Ship
Slipen Mek. Verksted AS Norway 43 Hardingen Passenger/Ro-Ro Ship
Slipen Mek. Verksted AS Norway 45 Vikingen Passenger/Ro-Ro Ship
Trnderverftet AS Norway 43 Bjrnsund Passenger/Ro-Ro Ship
Trnderverftet AS Norway 66 Rennesy Passenger/Ro-Ro Ship
Ulstein Verft Norway 68 Landego Passenger/Ro-Ro Ship
Lindstl Risr Norway Pilot boat
Ulstein Verft Norway 257 Normand Cutter Pipe Layer Crane Vessel
Ulstein Verft Norway 258 Normand Clipper Pipe Layer Crane Vessel
Aker Yards Brevik Norway 45 Island Champion Platform Supply Ship
Aker Yards Brevik Norway 46 Island Challanger Platform Supply Ship
Aker Yards Brevik Norway 57 Island Empress Platform Supply Ship
Aker Yards Langsten Norway 193 Bourdon Jade Platform Supply Ship
Simek Flekkefjord Norway 119 Asso Trenta Platform Supply Ship
Yantai Raffles Shipyard Co Ltd China 2003-145 Caledonian Vanguard Platform Supply Ship
Yantai Raffles Shipyard Co Ltd China 2003-146 Caledonian Vision Platform Supply Ship
Yantai Raffles Shipyard Co Ltd China 2003-147 Caledonian VigiIance Platform Supply Ship
Yantai Raffles Shipyard Co Ltd China 2003-148 Caledonian Victory Platform Supply Ship
Scheepswerf De Hoop Lobith B.V Holland 423 Caballo Criollo Platform Supply Ship
Yokohama Zosen - Chiba Japan 1380 Ocean Fighter Platform Supply Ship
Aker Yards Brattvg Norway 111 REM Supplier Platform Supply Ship
Aker Yards Brevik Norway 38 Olympic Progress Platform Supply Ship
Aker Yards Brevik Norway 39 Olympic Promoter Platform Supply Ship
Aker Yards Brevik Norway 40 Greatship Dipti Platform Supply Ship
Aker Yards Brevik Norway 41 Island Spirit Platform Supply Ship
Aker Yards Brevik Norway 49 Far Searcher Platform Supply Ship
Aker Yards Langsten Norway 197 Viking Avant Platform Supply Ship
Aker Yards Langsten Norway 198 Bourbon Emerald Platform Supply Ship
Aker Yards Sviknes Norway 138 North Mariner Platform Supply Ship
Fitjar Mek Verksted Norway 29 Skandi Commander Platform Supply Ship
Flekkefjord Slip & Maskinfabrikk AS Norway 173 Edda Fjord Platform Supply Ship
Karmsund Maritime Norway 21 Surf Viking Platform Supply Ship
Kleven Verft AS - Ulsteinvik Norway 301 Stril Pioner Platform Supply Ship
Kleven Verft AS - Ulsteinvik Norway 303 Viking Energy Platform Supply Ship
Mjellem & Karlsen AS Norway 80 HDW Herkules Platform Supply Ship
Myklebust Mek. V. Norway 33 Skandi Sotra Platform Supply Ship
Simek Flekkefjord Norway 110 Portosalvo Platform Supply Ship
Simek Flekkefjord Norway 116 REM Supporter Platform Supply Ship
Simek Flekkefjord Norway 117 REM Server Platform Supply Ship
5 (8)
Theunissen Technical Trading BV Postbus 70 6580 AB Malden Holland Tel. +31 (0)24-3584455 Fax. +31 (0)24-3582166 www.tttbv.nl
Shipyard Country Hull no. Vessel name Vessel type
West Contractors AS Norway 19 Viking Surf Platform Supply Ship
West Contractors AS Norway 21 Viking Nereus Platform Supply Ship
West Contractors AS Norway 27 Viking Athene Platform Supply Ship
Pan-United Marine Ltd. Singapore 167 Pacfic Askari Platform Supply Ship
Pan-United Marine Ltd. Singapore 168 Pacfic Assegai Platform Supply Ship
Orskov Christensens Staalskibsvft A/S Denmark 118 Gunnar Thorsen Pollution Control Vessel
Orskov Christensens Staalskibsvft A/S Denmark 119 Gunnar Seidenfaden Pollution Control Vessel
Mitsubishi Heavy Industries Ltd. Japan 837 Search Research Survey Vessel
Aker Yards Sviknes Norway 129 Geco Scorpio Research Survey Vessel
Bergen Mekaniske Verft Norway 160 Geo Celtic Research Survey Vessel
Bergen Mekaniske Verft Norway 161 Furgo Saltire Research Survey Vessel
Drammen Slip & Verksted Norway 101 CGG Venturer Research Survey Vessel
Fjellstrand AS - Omastrand Norway 1678 Geograph Research Survey Vessel
Flekkefjord Slip & Maskinfabrikk AS Norway 150 Geco Diamond Research Survey Vessel
Havyard Leirvik Norway 76 Polarbjrn Research Survey Vessel
Kleven Lland Norway 95 CGG Princess Research Survey Vessel
Solstrand AS - Tomrefjord Norway 80 Geo Barents Research Survey Vessel
Vaagen Verft AS Norway 55 CGG Duke Research Survey Vessel
Pomerania yard Szczecin Poland Nimbus Research Survey Vessel
Pomerania yard Szczecin Poland Nordsyssel Research Survey Vessel
Langsten Slip & Btbyggeri AS Retrofit 124 Nordic Explorer Research Survey Vessel
Sasebo Heavy Industries Co. Ltd Japan 256 MV Cape Taylor Ro-Ro Cargo Ship
Dalian Shipyard Co Ltd - Dalian LN China ST1150-1 Ragnhild Knutsen Shuttle Tanker
Wartsila Turku Shipyard Finland 1291 Anna Knutsen Shuttle Tanker
ASL Shipyard Pte Ltd Singapore 807 Esvagt Carpathia Standby Safety Vessel
ASL Shipyard Pte Ltd Singapore 808 Esvagt Cassiopeia Standby Safety Vessel
Karstensens Skibsvrft AS Denmark 394 Brendelen Stern Trawler
Hellesy Verft Norway 142 Gardar Stern Trawler
Kleven Verft AS - Ulsteinvik Norway 290 Vilhelm Torsteinsson Stern Trawler
Karstensens Skibsvrft AS Denmark 386 Atlantic Destiny Stern Trawler
Karstensens Skibsvrft AS Denmark 389 Aine Stern Trawler
Aker Yards Langsten Norway 183 Gudmundur I Nesi Stern Trawler
Fitjar Mek Verksted Norway 28 Libas Stern Trawler
O. Ulvan Baatbyggeri AS Norway 423 Asbjrn Selsbane Stern Trawler
Rabben Mek. Verksted Norway 101 Johan Feyer Stern Trawler
Szczecinska Stocznia Remontowa Poland PN04 Krossfjord Stern Trawler
Aker Yards Brattvg Norway 117 Subsea IMR
Flekkefjord Slip & Maskinfabrikk AS Norway 127 Supply vessel
Havyard Leirvik Norway 77 Supply vessel
Karmsund Maritime Norway 18 Nimbus Supply vessel
Kleven Verft AS - Ulsteinvik Norway 297 Siddis Skipper Supply vessel
Myklebust Mek. V. Norway 37 Skandi Captain Supply vessel
Simek Flekkefjord Norway 76 Far Sky Supply vessel
Simek Flekkefjord Norway 98 Far Swan Supply vessel
Simek Flekkefjord Norway 99 Far Saga Supply vessel
Simek Flekkefjord Norway 103 Seabulk Africa Supply vessel
Simek Flekkefjord Norway 106 de vries tide Supply vessel
Simek Flekkefjord Norway 111 Dina Mercur Supply Vessel
Aas Mek Verksted Norway 171 Fob Jr. Supply/Working
Kaarboverkstedet AS Norway KNM Sarpen Torpedo recovery
Karstensens Skibsvrft AS Denmark 390 Neptune Trawler
Karstensens Skibsvrft AS Denmark 391 Western Chieftain Trawler
6 (8)
Theunissen Technical Trading BV Postbus 70 6580 AB Malden Holland Tel. +31 (0)24-3584455 Fax. +31 (0)24-3582166 www.tttbv.nl
Shipyard Country Hull no. Vessel name Vessel type
Karstensens Skibsvrft AS Denmark 392 Girl Stephanie Trawler
Karstensens Skibsvrft AS Denmark 393 Father Mckee Trawler
Karstensens Skibsvrft AS Denmark 395 Trawler
Karstensens Skibsvrft AS Denmark 398 Silva Trawler
Simek Flekkefjord Norway 108 Pathway Trawler
Simek Flekkefjord Norway 109 Julianne III Trawler
UMOE Sterkoder Norway 226 Mersey Phoenix Trawler Canada
Odense Staalskibsvaerft A/S - Lind Denmark 709 Svitzer Mull Tug
Odense Staalskibsvaerft A/S - Lind Denmark 705 Svitzer Mjlner Tug
Odense Staalskibsvaerft A/S - Lind Denmark 706 Svitzer Milford Tug
Odense Staalskibsvaerft A/S - Lind Denmark 707 Svitzer Muiden Tug
Odense Staalskibsvaerft A/S - Lind Denmark 708 Svitzer Marken Tug
Odense Staalskibsvaerft A/S - Lind Denmark 710 Svitzer Menja Tug
Odense Staalskibsvaerft A/S - Lind Denmark 711 Svitzer Mallaig Tug
Odense Staalskibsvaerft A/S - Lind Denmark 712 Svitzer Maltby Tug
Odense Staalskibsvaerft A/S - Lind Denmark 713 Svitzer Mercur Tug
Tebma Shipyards Ltd India 125 Vallarpadam Tug
Tebma Shipyards Ltd India 126 Vypeen Tug
Aker Yards Langsten Norway 199 Polar Pevek Tug
Moen Slipp AS Norway 50 Baut Tugboat
Moen Slipp AS Norway 63 BB Server Tugboat
Simek Flekkefjord Norway 83 Thorax Tugboat
James Lamont & Co. Ltd UK 432 Hordafor II Waste Disposal Vessel
Aarhus Shipyard Denmark 245 Yacht
TBN Holland 187 TBN Yacht
TBN Holland 13750 TBN Yacht
TBN Holland 14047 TBN Yacht
C.R.N. Cant. Nav. Ancona S.r.l. Italy 119 Ability Yacht
Yantai Raffles Shipyard Co Ltd China 2004-178 Yacht Express Yacht carrier
Aker Yards Brevik Norway 59
Aker Yards Brevik Norway 62
Aker Yards Langsten Norway 213
Fiskerstrand Verft Norway 55
Fiskerstrand Verft Norway 56
Fiskerstrand Verft Norway 57
Fiskerstrand Verft Norway 58
Flekkefjord Slip & Maskinfabrikk AS Norway 184
Grovfjord Mek Verk. Norway 29 Triton
Hellesy Verft Norway 144
Kvrner Kleven Leirvik Norway 261
Moen Slipp AS Norway 64
Sletta Btbygg Norway 91
7 (8)
Theunissen Technical Trading BV Postbus 70 6580 AB Malden Holland Tel. +31 (0)24-3584455 Fax. +31 (0)24-3582166 www.tttbv.nl
Referencelist Eltek Fire Detection
01-07-2012 Page 1 of 3
Referencelist Eltek Fire Detection
01-07-2012 Page 2 of 3
Referencelist Eltek Fire Detection
01-07-2012 Page 3 of 3