You are on page 1of 26

Mostyn Enterprises

Remote Radio Transmission System


OVERVIEW
Mostyn Enterprises has developed a cost effective solution for protection of a field force HQ
from detection of its position by the use of EW.
Conventional Headquarters
Mostyns Solution
Frequency Coverage & Amplification

Frequencies Coverage
1.6-30Mhz HF Band
32-88Mhz VHF Tactical Radio
88-512Mhz VHF-UHF

RF power amplifiers
150W nominal VHF-UHF
400W nominal HF
RF Over Fibre Block Diagram

*Existing system currently in service


RF Over Fibre Specifications

Breakdown of Frequency Allocations


Parameter Value
Transmit frequency range, UHF Satcom mode 270 to 320 MHz
Receive frequency range, UHF Satcom mode 243 to 270 MHz
Transmit frequency range, VHF Lo LOS mode 30 to 110 MHz
Transmit frequency range, VHF Hi LOS mode 90 to 225 MHz
Transmit frequency range, UHF LOS mode 225 to 512 MHz
Receive frequency range, VHF Lo LOS mode 30 to 110 MHz
Receive frequency range, VHF Hi LOS mode 90 to 225 MHz
Receive frequency range, UHF LOS mode 225 to 512 MHz
Minimum guard band, Tx to Rx for LOS mode 4 MHz
RF Over Fibre Specifications
Parameter Value
Transmit power to Antenna 0 to 50 Watts
Receive signal level at Antenna -117 dBm min
Duty cycle 10% Tx, 90% Rx
Modulation modes FSK, ASK, PSK, FM, AM
All RF connectors N type with waterproof o ring seal
All fibre optic connectors Ruggedized
All data connectors Panel mount, IP68 rated.
All switches and indicators Panel mount, IP68 rated
Receive/transmit change over time 20 mSec max
Indoor unit power source Standard: Widemouth input 90 to 260 V AC
Option: 24V DC in (vehicle battery)
Max power requirement: 50 watts
Outdoor unit power source Standard: Widemouth input 90 to 260 V AC
Option: 24V DC in (vehicle battery)
Max power requirement: 300 watts
Indoor equipment housing Stand-alone box to IP67, rack shelf mountable - Ruggedized
Outdoor equipment housing Stand-alone box to IP68, mast mountable - Ruggedized
Operating temperature range, both equipments -20 to +50 deg. C
Humidity, operating and storage 0 to 90% non condensing
Altitude, operating and storage 15000 feet
Trailer
Isometric View Trailer doors opened
Trailer
Front and Rear View
Trailer
Top View
Trailer
Side View
Trailer Specifications
Trailer Dimensions
Height from ground
Width
Length without towbar
Length with towbar

Trailer Cover
Sides tied down to the sides of the trailer with zips at each end and will be
provided with 4 poles with guise so when the trailer is operational (fixed
position), the poles can hold the covers out to provide protection for the
operators.
Power source
Fuel Cell
Ethanol based Diesel version in development
3-5kW
240V AC single phase
26V DC 50amp
48V DC 25amp
Storage batteries are optional

Backup power source


110/240V Output diesel generator
Adequate fuel tank to provide 3 days at full power
Heat exchanges used for forced air flow to reduce the thermal signature
Power Source

Fuel tank

Heat exchanges

Water tank

Under development
Cable Reels

Under development
Cable

Under development
Antennas

Under development
Typical Antenna Systems
Drawing of typical antenna systems.
Typical Antenna Systems
Drawing of typical antenna systems.
Statistics Remote System
Fully operation remote system would consist of:
Matrix switch(16x16)
Based on Mostyn Enterprises 256x256 matrix switch.
4x4 quadrature lumped element hybrids
6x2 quadrature lumped element hybrids
9 power amplifiers
3 HF 1.6-30Mhz
6 VHF 30-512Mhz
1 fuel cell power generator
1 backup diesel generator
16 antennas HF, VHF & UHF
16 cable drums with coaxial cable (100m)
2 cable drums with optic cable (500m-1000m)
1 order wire system for operator communication between remote site and main site
Base system will able to handle 14 HF/VHF radios controlled by a 16x24 matrix switch.
Expanded systems TBA
Matrix Switch
The matrix switch is based on one of our standard designs and will suit the
overall requirement for the system, forming part of the switch will be
combiners, Frequency counters, bi-directional couplers, these form the test
capabilities and the safety checking system confirming the switch operates
in a safe manner including the associated equipment.
Statistics Local System
Fully operation local system would consist of:
Local switching system to switch between local antennas and remote
system as required
RF to fibre interface
RF monitoring capabilities
RF power attenuators with automatic output control
Order wire system for communicating to remote location
QUESTIONS
Any questions or comments?
Engineering Capabilities
R.F. Analogue circuit design
o Switching Systems
Digital circuit design
o Power Amplifiers
o Filters Systems integration
o Splitter/combiners
Resistive Navigation systems
Quadrature lumped Data Logging
element
o HF Antenna Tuning Units Turnkey Solutions
Contact Details

Mostyn Enterprises (Technologies) Pty Ltd

Unit 5/12 Severn Street

St. Marys 2760, Australia

Phone: +61 (02) 9194 3470

Mobile: +61 414 716 311

Email: btainsh@mostynent.com

You might also like