6

CONTROL AND SIGNALLING UNITS

Push buttons and selector switches


Metal and plastic, with quick
installation by simple rotation
Standard IP65 front degree of
protection
Highly conductive contacts
PAGES 6-2 TO 6 PAGES 6-4 AND 7 PAGES 6-5 AND 7
PAGES 6-10 TO 14 PAGES 6-12 AND 15 PAGES 6-13 AND 15 Contact operation: double

PLANET - SWITCH
BUTTON ACTUATORS 22mm DOUBLE AND TRIPLE TOUCH ACTUATORS 22mm SELECTOR ACTUATORS 22mm breaking action, direct opening
Spring return flush, extended and shrouded Double touch with or without indicator Knob operation and self cleaning
Push-push flush and extended Triple touch. Lever action.
Mushroom-head Key
Mechanical reset Illuminated. Signal towers 70mm
Illuminated. Modular and combinations up to
7 modules
Steady or blinking light, pulsed or
continuous sound modules.

Signal beacons 62mm


Steady or blinking light , pulsed
or continuous sound modules.
SEC. PAGE
Metal button and selector actuators 22mm
Push-button actuators, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 2
Push-push button actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 3
Mushroom-head push-button actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 3
Mechanical reset button, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 4
Double-touch button actuators, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 4
Triple-touch button actuators, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 4
PAGE 6-8 PAGE 6-9 PAGE 6-16 AND 6-17 Selector actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 5
Illuminated button actuators, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 6
METAL POTENTIOMETER DRIVES 22mm METAL JOYSTICKS 22mm PILOT LIGHTS 22mm
Graduated scale 2 directions Monoblock LED Illuminated push-push actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 6
Variable index. 4 directions Conventional monoblock. Illuminated mushroom-head actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 6
2 directions with mechanical interlock MONOBLOCK BUZZERS 22mm Illuminated selector actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 7
4 directions with mechanical interlock Pulse-tone. Double-touch button actuators, spring return, with indicator . . . . . . . . . . . . . . 6- 7
Complete with auxiliary contacts. Pilot light heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 8
Potentiometer drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 8
Joysticks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 9
Plastic button and selector actuators 22mm
Push-button actuators, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 10
Push-push button actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 11
Mushroom-head push-button actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 11
Mechanical reset button, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 12
Double-touch button actuators, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 12
Triple-touch button actuators, spring return . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 12
Selector actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 13
Illuminated button actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 14
Illuminated mushroom-head actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 14
Illuminated selector actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 14
Double-touch button actuators, spring return, with indicator . . . . . . . . . . . . . . 6- 15
Monoblock LED pilot lights, steady light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 16
PAGES 6-17 PAGES 6-18 TO 23 PAGES 6-24 TO 27 Monoblock pilot lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 16
CONTROL STATIONS ADD-ON ELEMENTS, ACCESSORIES AND SPARE SIGNAL TOWERS AND BEACONS Monoblock buzzers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 17
1 to 5 positions without actuators PARTS FOR ACTUATORS AND SELECTORS Signal towers 70mm
Complete units with 1 button. Mounting adapter Signal beacons 62mm Control stations 6- 17
Contact elements Steady, blinking light or flash modules Add-on elements for buttons and selectors . . . . . . . . . . . . 6- 18
Lamp holders Sound modules
LED integrated lamp holders Incandescent and LED bulbs.
Accessories and spare parts for buttons and selectors 6- 21
Labelling and label holders Signal towers and beacons
Bulbs. Signal towers 70mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 24
Signal beacons 62mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 25

REV. 02_11
6-2 Control and signalling units electric
Metal button and selector actuators 22mm

Push-button Order code Colour Qty Wt Operational characteristics


actuators, spring per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
return Storage temperature: -40...+70C
Flush (without mounting adapter). Spring return. Any mounting position is allowed
8 LM2T B102 Black 10 0.033 Degree of protection:
8 LM2T B103 Green 10 0.033 Per IEC/EN: IP65
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
8 LM2T B104 Red 10 0.033
8 LM2T B10...
8 LM2T B105 Yellow 10 0.033 Materials
8 LM2T B106 Blue 10 0.033 An aluminium and zinc alloy (zama) is used for the metal
part whereas plastic parts are made of polyamide and
8 LM2T B108 White 10 0.033 polycarbonate.
Extended (without mounting adapter). Spring return.
8 LM2T B202 Black 10 0.035 Mechanical endurance
Operating force: 0.8kg (actuator).
8 LM2T B203 Green 10 0.035 Mechanical life: 1,000,000 cycles.
8 LM2T B204 Red 10 0.035
8 LM2T B205 Yellow 10 0.035 Mounting adapter
8 LM2T B20... See page 6-18.
8 LM2T B206 Blue 10 0.035 Type: LM2T AU120.
6 8 LM2T B208 White 10 0.035 Actuators latch onto the mounting adapter by simple
Shrouded (without mounting adapter). Spring return. rotation.
The adapter is fixed to the mounting surface by means
8 LM2T B302 Black 10 0.035 of incorporated screws (Tmax = 0.8Nm).
8 LM2T B303 Green 10 0.035
8 LM2T B304 Red 10 0.035 Auxiliary contacts
See page 6-18.
8 LM2T B305 Yellow 10 0.035 Type: LM2T C10 (1NO)
8 LM2T B30...
8 LM2T B306 Blue 10 0.035 LM2T CF10 (1NO Faston)
8 LM2T B308 White 10 0.035 LM2T C10A (EM)
LM2T C01 (1NC)
LM2T CF01 (1NC Faston)
LM2T C01D (LB)
Push-button Order code Symbol Colour Qty Wt
actuators, spring per pkg Auxiliary contacts snap onto the mounting adapter.
n [kg] Up to 6 auxiliary contacts can be fitted on the mounting
return, with symbol adapter: 2 on the left, 2 at the centre and 2 on the right.
Flush (without mounting adapter). Spring return. To mount the auxiliary contacts in the centre position,
8 LM2T B1102 O Black 10 0.033 use the accessory: LM2T A140 (see page 6-22).
8 LM2T B1104 Red 10 0.033
8 LM2T B1113 I Green 10 0.033
CLICK
8 LM2T B1118 White 10 0.033
8 LM2T B1123 II Green 10 0.033
8 LM2T B11... 8 LM2T B1128 White 10 0.033
8 LM2T B1132 STOP Black 10 0.033
8 LM2T B1134 Red 10 0.033
8 LM2T B1142 Black 10 0.033
 LM2T A140
8 LM2T B1148 White 10 0.033
8 LM2T B1152 Black 10 0.033
  The action plug LM2T A140 for the centre position is not standard
8 LM2T B1158 White 10 0.033
supplied and must be purchased separately.
8 LM2T B1163 START Green 10 0.033
8 LM2T B1168 White 10 0.033 Certifications and compliance
8 LM2T B21... Certifications obtained: cULus, RINA, LROS, GOST, CCC.
8 LM2T B1176 R Blue 10 0.033
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
8 LM2T B1178 White 10 0.033 UL508; CSA C22.2 n 14.
8 LM2T B1196 RESET Blue 10 0.033
8 LM2T B1502 Black 10 0.033
8 LM2T B1512 Black 10 0.033
Extended (without mounting adapter). Spring return.
8 LM2T B2102 O Black 10 0.035
8 LM2T B2104 Red 10 0.035
8 LM2T B2132 STOP Black 10 0.035
8 LM2T B2134 Red 10 0.035
 Arrow symbol can be used to indicate right or left.
 Arrow symbol can be used to indicate up or down.

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
electric
Control and signalling units 6-3
Metal button and selector actuators 22mm

Push-push button Order code Colour Qty Wt Operational characteristics


actuators per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
Storage temperature: -40...+70C
Flush (without mounting adapter). Push on-push off. Any mounting position is allowed
8 LM2T Q102 Black 10 0.033 Degree of protection:
8 LM2T Q103 Green 10 0.033 Per IEC/EN: IP65 for push-push and LM2T B654
actuators; IP66 for others.
8 LM2T Q104 Red 10 0.033 Per UL: type 1, 2, 3R, 4, 4X, 12, 12K except for
8 LM2T Q10... 8 LM2T Q105 Yellow 10 0.033 8 LM2T B616 which is type 1, 2, 3R, 12, 12K.
8 LM2T Q106 Blue 10 0.033 Materials
8 LM2T Q108 White 10 0.033 An aluminium and zinc alloy (zama) is used for the metal
Extended (without mounting adapter). Push on-push off. part whereas plastic parts are made of polyamide and
polycarbonate.
8 LM2T Q202 Black 10 0.035
8 LM2T Q203 Green 10 0.035 Mechanical endurance
8 LM2T Q20... Operating force: 0.8kg (actuator).
8 LM2T Q204 Red 10 0.035 Mechanical life:
8 LM2T Q205 Yellow 10 0.035 Push-push actuators: 500,000 cycles
8 LM2T Q206 Blue 10 0.035 Mushroom head buttons: 1,000,000 cycles
8 LM2T Q208 White 10 0.035
Mushroom head latch buttons: 300,000 cycles. 6
 Use the early-make type, LM2T C10A only. Mounting adapter
No normally open contact element, LM2T C10, must be used with this See page 6-18.
type of button actuators. Type: LM2T AU120.
A maximum of 2 contact elements can be mounted only. Actuators latch onto the mounting adapter by simple
rotation.
Mushroom head Order code Colour Qty Wt The adapter is fixed to the mounting surface by means
per pkg of incorporated screws (Tmax = 0.8Nm).
push-button actuators
n [kg] Auxiliary contacts for push-push button actuators
Spring return. 40mm See page 6-18.
(without mounting adapter). Type: LM2T C10A (EM)
LM2T C01 (1NC)
8 LM2T B6142 Black 10 0.037 Auxiliary contacts snap onto the mounting adapter.
8 LM2T B6143 Green 10 0.037 Up to 2 auxiliary contacts can be fitted on the mounting
8 LM2T B6144 Red 10 0.037 adapter: 1 each on the right and left.
8 LM2T B614... 8 LM2T B6145 Yellow 10 0.037
8 LM2T B6146 Blue 10 0.037
Spring return. 60mm
(without mounting adapter).
8 LM2T B6162 Black 10 0.043
8 LM2T B6163 Green 10 0.043
8 LM2T B6164 Red 10 0.043
8 LM2T B6165 Yellow 10 0.043
8 LM2T B6166 Blue 10 0.043 Auxiliary contacts for mushroom-head button actuators
8 LM2T B616... Type: LM2T C10 (1NO)
Latch, pull to release. 40mm LM2T CF10 (1NO Faston)
(without mounting adapter). LM2T C10A (EM)
8 LM2T B6242 Black 10 0.105 LM2T C01 (1NC)
8 LM2T B6244 Red 10 0.105 LM2T CF01 (1NC Faston)
LM2T C01D (LB)
Latch, turn to release. 40mm Auxiliary contacts snap onto the mounting adapter.
(without mounting adapter). Up to 4 auxiliary contacts can be fitted on the mounting
8 LM2T B624... 8 LM2T B6342 Black 10 0.054 adapter with LM2T B624... and LM2T B6644 types: 2 on
8 LM2T B6344 Red 10 0.054 the right and 2 on the left only.
Up to 6 auxiliary contacts can be fitted on the mounting
Latch, turn key to release. 40mm adapter with all the other types: 2 on the left, 2 at the
(without mounting adapter). centre 2 on the right. To mount the auxiliary contacts in
8 LM2T B6542 Black 10 0.091 the centre position, use the accessory LM2T A140 (see
8 LM2T B6542G 1 0.091 page 6-22).
8 LM2T B6544 Red 10 0.091 CLICK
8 LM2T B634...
8 LM2T B6544G 1 0.091
Latch, turn to release, ISO 13850 (ex EN418) compliant.
40mm (without mounting adapter).
8 LM2T B6644 Red 10 0.087
 Versions with different key codes.
Complete with the numeric code of the key. The following versions are LM2T A140
available: 501, 502, 503, 504, 505, 506, 507, 508, 509, 510.
8 LM2T B654... Example of complete code: 8 LM2T B6542G505.
 The action plug LM2T A140 for the centre position is not standard
supplied and must be purchased separately.

Certifications and compliance


Certifications obtained: cULus, RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
UL508; CSA C22.2 n 14; also IEC/EN 60947-5-5 for
LM2T B6644.
8 LM2T B6644

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
6-4 Control and signalling units electric
Metal button and selector actuators 22mm

Mechanical reset Order code Colour Qty Wt Operational characteristics


buttons, complete per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
unit, spring return Storage temperature: -40...+70C
Flush (5.2mm stroke). Spring return. Any mounting position is allowed
Adjustable length 0-140mm max. Degree of protection:
8 LM2T R1002 Black 10 0.065 Per IEC/EN: IP65 for mechanical reset buttons; IP40
8 LM2T R1003 Green 10 0.065 for double and triple-touch actuators.
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K for
8 LM2T R1004 Red 10 0.065 8 LM2T R...; for 8 LM2T B71... and
8 LM2T R1006 Blue 10 0.065 8 LM2T B72... type 1.
8 LM2T R1196 Blue (RESET) 10 0.065
Materials
Extended (5.2mm stroke). Spring return. An aluminium and zinc alloy (zama) is used for the metal
Adjustable length 0-140mm max. part whereas plastic parts are made of polyamide and
8 LM2T R1196 8 LM2T R2004 Red 10 0.067 polycarbonate.
Complete with mounting adapter as well as the rod.
 With RESET caption on actuator. Mechanical endurance
Operating force: 0.8kg (actuator)
Mechanical life: 1,000,000 cycles
6 Double-touch Order code Colour Symbols Qty Wt
per pkg Mounting adapter
actuators, See page 6-18.
spring return n [kg] Type: LM2T AU120.
Two flush push-buttons (without mounting adapter). Actuators latch onto the mounting adapter by simple
Both spring return. rotation.
8 LM2T B7112 Black/Red none 5 0.044 The adapter is fixed to the mounting surface by means
of incorporated screws (Tmax = 0.8Nm).
8 LM2T B7113 Green/Red none 5 0.044
8 LM2T B7114 White/Black none 5 0:044 Auxiliary contacts for touch actuators
8 LM2T B7122 Black/Red I-O 5 0.044 See page 6-18.
Type: LM2T C10 (1NO)
8 LM2T B7123 Green/Red I-O 5 0.044 LM2T CF10 (1NO Faston)
8 LM2T B7124 White/Black I-O 5 0.044 LM2T C10A (EM)
8 LM2T B7133 Green/Red Start/Stop 5 0.044 LM2T C01 (1NC)
8 LM2T B71... LM2T CF01 (1NC Faston)
One extended and one flush push-buttons (without LM2T C01D (LB)
mounting adapter). Both spring return. Auxiliary contacts snap onto the mounting adapter.
8 LM2T B7212 Black/Red none 5 0.044
8 LM2T B7213 Green/Red none 5 0.044
8 LM2T B7214 White/Black none 5 0.044
8 LM2T B7222 Black/Red I-O 5 0.044
8 LM2T B7223 Green/Red I-O 5 0.044
8 LM2T B7224 White/Black I-O 5 0.044
8 LM2T B72... 8 LM2T B7233 Green/Red Start/Stop 5 0.044

Triple-touch Order code Symbols Qty Wt


actuators, per pkg
n [kg] DOUBLE-TOUCH ACTUATORS
spring return Up to 4 auxiliary contacts can be fitted on the mounting
Two external flush and one middle extended buttons adapter: 2 on the left and 2 on the right.
(without mounting adapter). All spring return.
8 LM2T B7345 5 0.044 TRIPLE-TOUCH ACTUATORS
Up to 6 auxiliary contacts can be fitted on the mounting
adapter: 2 on the left, 2 in the centre and 2 on the right.
STOP
Certifications and compliance
Certifications obtained: cULus, RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
8 LM2T B7355 5 0.044 UL508; CSA C22.2 n 14.
8 LM2T B73...
STOP

8 LM2T B7365 5 0.044

STOP

8 LM2T B7375 5 0.044

STOP

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
electric
Control and signalling units 6-5
Metal button and selector actuators 22mm

Selector actuators Order code Type of Qty Wt Operational characteristics


knob positions per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
Storage temperature: -40...+70C
2 position (without mounting adapter). Any mounting position is allowed
8 LM2T S120 10 0.049 Degree of protection:
8 LM2T S121 10 0.049 Per IEC/EN: IP65
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
3 position (without mounting adapter).
8 LM2T S130 10 0.049 Materials
8 LM2T S1... An aluminium and zinc alloy (zama) is used for the metal
8 LM2T S131 10 0.049
part whereas plastic parts are made of polyamide and
8 LM2T S132 10 0.049 polycarbonate.
8 LM2T S133 10 0.049
Mechanical endurance
Mechanical life: 300,000 cycles.
Selector actuators Order code Type of Qty Wt
lever positions per pkg Mounting adapter
n [kg] See page 6-18.
Type: LM2T AU120.
2 position (without mounting adapter). Actuators latch onto the mounting adapter by simple
8 LM2T S220 10 0.050 rotation. 6
8 LM2T S221 10 0.050 The adapter is fixed to the mounting surface by means
of incorporated screws (Tmax = 0.8Nm).
3 position (without mounting adapter).
8 LM2T S230 10 0.050 Auxiliary contacts
8 LM2T S231 10 0.050 See page 6-18.
8 LM2T S2... Type: LM2T C10 (1NO)
8 LM2T S232 10 0.050 LM2T CF10 (1NO Faston)
8 LM2T S233 10 0.050 LM2T C10A (EM)
LM2T C01 (1NC)
LM2T CF01 (1NC Faston)
LM2T C01D (LB)
Selector actuators Order code Type of Qty Wt Auxiliary contacts snap onto the mounting adapter.
key positions per pkg Up to 4 auxiliary contacts can be fitted on the mounting
n [kg] adapter: 2 on the left and 2 on the right. For more,
2 position (without mounting adapter). contact our Customer Service (Tel. +39 035 4282422;
email: service@LovatoElectric.com) for advice.
8 LM2T S320 10 0.079
8 LM2T S320G 1 0.079
8 LM2T S321 10 0.079
8 LM2T S321G 1 0.079
8 LM2T S340 10 0.079
8 LM2T S3... 8 LM2T S340G 1 0.079
3 position (without mounting adapter).
8 LM2T S330 10 0.080 Positions
8 LM2T S330G 1 0.080 Stay put position.
8 LM2T S331 10 0.080 Spring return position.
8 LM2T S331G 1 0.080 Key extraction position.
8 LM2T S332 10 0.080
8 LM2T S332G 1 0.080 Angles
2 position 3 position
8 LM2T S333 10 0.080 45
45
90
8 LM2T S333G 1 0.080
8 LM2T S350 10 0.080
8 LM2T S350G 1 0.080
8 LM2T S360 10 0.080 Special versions
8 LM2T S360G 1 0.080 Versions with coloured keys are available upon request.
Contact our Customer Service (Tel. +39 035 4282422;
8 LM2T S370 10 0.080 email: service@LovatoElectric.com).
8 LM2T S370G 1 0.080
8 LM2T S380 10 0.080 Certifications and compliance
Certifications obtained: cULus, RINA, LROS, GOST, CCC.
8 LM2T S380G 1 0.080 Compliant with standards: IEC/EN 60947-1,
8 LM2T S390 10 0.080 IEC/EN 60947-5-1; UL508; CSA C22.2 n 14.
8 LM2T S390G 1 0.080
 Versions with different key codes.
Complete with the numeric code of the key. The following versions are
available: 501, 502, 503, 504, 505, 506, 507, 508, 509, 510.
Example of complete code: 8 LM2T S320G505.
 Available only on specific request.

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
6-6 Control and signalling units electric
Metal button and selector actuators 22mm

Illuminated button Order code Colour Qty Wt Operational characteristics


actuators, spring per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
return Storage temperature: -40...+70C
Flush (with side visibility). Spring return. Any mounting position is allowed
(without mounting adapter). Degree of protection:
8 LM2T BL103 Green 10 0.033 Per IEC/EN: IP65
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
8 LM2T BL104 Red 10 0.033
Materials
8 LM2T BL105 Yellow 10 0.033
8 LM2T BL10... An aluminium and zinc alloy (zama) is used for the metal
8 LM2T BL106 Blue 10 0.033 part whereas plastic parts are made of polyamide and
8 LM2T BL107 Transparent 10 0.033 polycarbonate.
Extended (without mounting adapter). Spring return. Mechanical endurance
Operating force: 0.8kg (actuator).
8 LM2T BL203 Green 10 0.035 Mechanical life:
8 LM2T BL204 Red 10 0.035 Push-push actuators: 500,000 cycles
8 LM2T BL205 Yellow 10 0.035 Mushroom head latch buttons: 300,000 cycles
All others: 1,000,000 cycles.
8 LM2T BL206 Blue 10 0.035
8 LM2T BL20... Mounting adapter
8 LM2T BL207 Transparent 10 0.035 See page 6-18.
6 Type: LM2T AU120.
Actuators latch onto the mounting adapter by simple
Push-push button Order code Colour Qty Wt rotation.
actuators per pkg The adapter is fixed to the mounting surface by means
n [kg] of incorporated screws (Tmax = 0.8Nm).
Auxiliary contacts for illuminated push-push actuators:
Flush (without mounting adapter). Push on-push off.
See page 6-18.
8 LM2T QL103 Green 10 0.033 Type: LM2T C10A (EM)
8 LM2T QL104 Red 10 0.033 LM2T C01 (1NC)
Auxiliary contacts snap onto the mounting adapter.
8 LM2T QL105 Yellow 10 0.033
Up to 2 auxiliary contacts can be fitted on the mounting
8 LM2T QL106 Blue 10 0.033 adapter in a row, 1 each on the right and left, along with
8 LM2T QL10...
8 LM2T QL107 Transparent 10 0.033 the lamp-holder in the centre position, of which
LM2T DL400, LM2T EL400, LM2T VL230, LM2T ZL230,
Extended (without mounting adapter). Push on-push off.
LM2T L... or LM2T M... (see page 6-19).
8 LM2T QL203 Green 10 0.035 With lamp-holder LM2T XL..., LM2T YL..., LM2T FL... or
8 LM2T QL204 Red 10 0.035 LM2T GL..., one auxiliary contact can be mounted only.
8 LM2T QL205 Yellow 10 0.035 Auxiliary contacts for illuminated button or
mushroom-head actuators:
8 LM2T QL206 Blue 10 0.035
See page 6-18.
8 LM2T QL20... 8 LM2T QL207 Transparent 10 0.035 Type: LM2T C10 (1NO)
 Use only the early-make type, LM2T C10A. LM2T CF10 (1NO Faston)
No normally open contact element, LM2T C10, must be used with this LM2T C10A (EM)
type of button actuators. LM2T C01 (1NC)
A maximum of 2 contact elements can be mounted only. LM2T CF01 (1NC Faston)
LM2T C01D (LB)
Auxiliary contacts snap onto the mounting adapter.
On LM2T BL1, LM2T BL2 or LM2T BL61 actuators, the
following can be fitted on the mounting adapter:
Illuminated Order code Colour Qty Wt Up to 4 contacts, 2 each on the left and right, when
per pkg one of the following lamp-holders is used:
mushroom head LM2T DL400, LM2T EL400, LM2T VL230,
button actuators n [kg]
LM2T ZL230, LM2T L or LM2T M (see page 6-19).
Spring return. 40mm (without mounting adapter). Up to 2 contacts, one on top of the other of the same
8 LM2T BL6143 Green 10 0.043 type only, when one of the following lamp-holders is
used LM2T XL, LM2T YL, LM2T FL or LM2T GL (see
8 LM2T BL6144 Red 10 0.043
page 6-19).
8 LM2T BL6145 Yellow 10 0.043 On LM2T BL62... actuator, the following can be fitted on
8 LM2T BL6146 Blue 10 0.043 the mounting adapter:
Up to 2 contacts, 1 each on the right and left, when
8 LM2T BL6148 White 10 0.043
8 LM2T BL614... one of the following lamp-holders is used
Latch, pull to release. 40mm (without mounting adapter). LM2T DL400, LM2T EL400, LM2T VL230,
8 LM2T BL6243 Green 10 0.105 LM2T ZL230, LM2T L or LM2T M (see page 6-19)
Up to 2 contacts, one on top of the other of the same
8 LM2T BL6244 Red 10 0.105
type only, when one of the following lamp-holders is
8 LM2T BL6245 Yellow 10 0.105 used: LM2T XL, LM2T YL, LM2T FL or LM2T GL (see
8 LM2T BL6246 Blue 10 0.105 page 6-19).
8 LM2T BL6248 White 10 0.105
 The number of auxiliary contacts to be mounted is given in the side
notes.
 A maximum of 2 auxiliary contacts can be mounted only. Lamp-holder elements
8 LM2T BL624... See page 6-19 and 20.
Bulbs
Maximum recommended power: 1.2W.
See page 6-22.
Certifications and compliance
Certifications obtained: cULus, RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
UL508; CSA C22.2 n 14.

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
electric
Control and signalling units 6-7
Metal button and selector actuators 22mm

Double touch Order code Colour Symbol Qty Wt Operational characteristics


actuators, spring per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
return, white Storage temperature: -40...+70C
Two flush push-buttons (without mounting adapter).
indicator Both spring return.
Any mounting position is allowed
Degree of protection:
8 LM2T BL7112 Black/Red none 5 0.044 Per IEC/EN: IP65 for selectors;
8 LM2T BL7113 Green/Red none 5 0.044 IP40 for double-touch actuators.
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K except for
8 LM2T BL7114 White/Black none 5 0.044 8 LM2T BL71... and 8 LM2T BL72... which are type 1.
8 LM2T BL7122 Black/Red I-O 5 0.044 Materials
8 LM2T BL7123 Green/Red I-O 5 0.044 An aluminium and zinc alloy (zama) is used for the metal
8 LM2T BL7124 White/Black I-O 5 0.044 part whereas plastic parts are made of polyamide and
8 LM2T BL711... 8 LM2T BL721... polycarbonate.
8 LM2T BL7133 Green/Red Start/Stop 5 0.044
Mechanical endurance
One extended and one flush push-buttons (without Operating force: 0.8kg (double touch actuator).
mounting adapter). Mechanical life: 300,000 cycles for selectors;
Both spring return. 1,000,000 cycles for double-touch actuators.
8 LM2T BL7212 Black/Red none 5 0.044 Mounting adapter
8 LM2T BL7213 Green/Red none 5 0.044 See page 6-18.
8 LM2T BL7214 White/Black none 5 0.044 Type: LM2T AU120. 6
Actuators latch onto the mounting adapter by simple
8 LM2T BL7222 Black/Red I-O 5 0.044 rotation.
8 LM2T BL7223 Green/Red I-O 5 0.044 The adapter is fixed to the mounting surface by means of
LM2T A12...
8 LM2TA12...

8 LM2T BL7224 White/Black I-O 5 0.044 incorporated screws (Tmax = 0.8Nm).


8 LM2T BL7233 Green/Red Start/Stop 5 0.044 Auxiliary contacts
See page 6-18.
Type: LM2T C10 (1NO)
LM2T CF10 (1NO Faston)
LM2T C10A (EM)
 The actuator is standard supplied with a white LM2T C01 (1NC)
diffuser. Coloured diffusers LM2T A12... can be
purchased separately. Refer to page 6-20. LM2T CF01 (1NC Faston)
LM2T C01D (LB)
Auxiliary contacts snap onto the mounting adapter.
Illuminated Order code Colour Type of Qty Wt DOUBLE-TOUCH ACTUATORS
selector actuators positions per pkg Up to 4 auxiliary contacts can be fitted on the mounting
n [kg] adapter: 2 on the left and 2 on the right.
SELECTOR ACTUATORS
2 position (without mounting adapter). On 2-position illuminated selectors, the following can be
8 LM2T SL1203 Green 10 0.025 fitted on the mounting adapter:
8 LM2T SL1204 Red 10 0.025 Up to 4 auxiliary contacts when the following types of
lamp-holders are used: LM2T DL400, LM2T VL230,
8 LM2T SL1205 Yellow 10 0.025 LM2T EL400, LM2T ZL230, LM2T L... or LM2T M... (see
8 LM2T SL1206 Blue 10 0.025 page 6-19).
8 LM2T SL1... 8 LM2T SL1208 White 10 0.025 Up to 2 auxiliary contacts when the following types of
lamp-holders are used: LM2T XL..., LM2T YL...,
8 LM2T SL1213 Green 10 0.025 LM2T FL... or LM2T GL... (see page 6-19).
8 LM2T SL1214 Red 10 0.025 On 3-position illuminated selectors, the following can be
8 LM2T SL1215 Yellow 10 0.025 fitted on the mounting adapter:
Up to 4 auxiliary contacts when the following types of
8 LM2T SL1216 Blue 10 0.025 lamp-holders are used: LM2T DL400, LM2T VL230,
8 LM2T SL1218 White 10 0.025 LM2T EL400, LM2T ZL230, LM2T L... or LM2T M... (see
3 position (without mounting adapter). page 6-19).
NOTE: The following lamp-holders cannot be mounted:
8 LM2T SL1303 Green 10 0.025 LM2T XL..., LM2T YL..., LM2T FL... or LM2T GL...
8 LM2T SL1304 Red 10 0.025
8 LM2T SL1305 Yellow 10 0.025 Selector positions
Stay put position.
8 LM2T SL1306 Blue 10 0.025
8 LM2T SL1308 White 10 0.025 Spring return position.
8 LM2T SL1313 Green 10 0.025 Selector angles
8 LM2T SL1314 Red 10 0.025 2 position 3 position
45 45
8 LM2T SL1315 Yellow 10 0.025 90

8 LM2T SL1316 Blue 10 0.025


8 LM2T SL1318 White 10 0.025 Lamp-holder elements for selector actuators
8 LM2T SL1323 Green 10 0.025 See page 6-19 and 20.
8 LM2T SL1324 Red 10 0.025 Lamp-holder elements for double-touch actuators
8 LM2T SL1325 Yellow 10 0.025 Use lamp-holder type LM2T DL400, LM2T EL400,
LM2T VL230, LM2T ZL230, LM2T L... or LM2T M...
8 LM2T SL1326 Blue 10 0.025 See page 6-19.
8 LM2T SL1328 White 10 0.025 Bulbs
8 LM2T SL1333 Green 10 0.025 Maximum recommended power: 1.2W.
8 LM2T SL1334 Red 10 0.025 See page 6-22.
8 LM2T SL1335 Yellow 10 0.025 Certifications and compliance
Certifications obtained: cULus, RINA, LROS, GOST, CCC.
8 LM2T SL1336 Blue 10 0.025 Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
8 LM2T SL1338 White 10 0.025 UL508; CSA C22.2 n 14.

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
6-8 Control and signalling units electric
Metal button and selector actuators 22mm

Pilot light head Order code Colour Qty Wt Operational characteristics


per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
Storage temperature: -40...+70C
Without mounting adapter. Any mounting position is allowed
8 LM2T IL103 Green 10 0.024 Degree of protection:
8 LM2T IL104 Red 10 0.024 Per IEC/EN: IP65
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
8 LM2T IL105 Yellow 10 0.024
8 LM2T IL10... 8 LM2T IL106 Blue 10 0.024 Materials
An aluminium and zinc alloy (zama) is used for the metal
8 LM2T IL107 Transparent 10 0.024
part whereas plastic parts are made of polyamide and
8 LM2T IL1187 Transparent  10 0.024 polycarbonate.
 With symbol indicating dangerous voltage (IEC 60417 5036-a).
Mounting adapter
LM2T AU120 LM2T AL... See page 6-18.
LM2T AU160
Type: LM2T AU120.
LM2T A160 Actuators latch onto the mounting adapter by simple
rotation.
The adapter is fixed to the mounting surface by means of
incorporated screws (Tmax = 0.8Nm).
6
LM2T DL400 Lamp-holder elements
LM2T FL... See page 6-19 and 20.
LM2T GL... LM2T A190
LM2T EL400 Bulbs
LM2T AT... Maximum recommended power: 1.2W.
LM2T VL230
LM2T ZL230 See page 6-22.
LM2T T100
LM2T YL... Certifications and compliance
LM2T XL... Certifications obtained: cULus, RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
LM2T L...
UL508; CSA C22.2 n 14.
LM2T M...
 The mounting adapter is standard supplied so there is no need to
purchase it as a separate accessory.
 Can be purchased separately. Refer to pages 6-21 and 23.

Potentiometer Order code Characteristics Qty Wt Operational characteristics


per pkg Suitable for potentiometers with 6-6.3mm diameter shaft
drive Minimum 40mm shaft length
n [kg] Ambient conditions:
8 LM2T P100 With graduated scale 10 O.070 Operating temperature: -25...+60C
8 LM2T P110 With variable index 10 O.070 Storage temperature: -40...+70C
Any mounting position is allowed
 Potentiometer not included, for assembly by the user. Degree of protection: IP65 (warranted by potentiometers
with a cylindrical shaft).

Materials
An aluminium and zinc alloy (zama) is used for the metal
part whereas plastic parts are made of polyamide and
8 LM2T P100 polycarbonate.
(complete with mounting adapter)
Mechanical endurance
Mechanical life: 300,000 cycles.

Mounting adapter
Standard supply with actuator.
Actuators latch onto the mounting adapter by simple
rotation.
The adapter is fixed to the mounting surface by means of
incorporated screws (Tmax = 0.8Nm).
8 LM2T P110 Certifications and compliance
(complete with mounting adapter)
Certifications obtained: GOST and CCC.
Compliant with standards: IEC/EN 60947-1,
IEC/EN 60947-5-1.

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 pages 6-21 and 23 page D-32

REV. 02_11
electric
Control and signalling units 6-9
Metal button and selector actuators 22mm

Joysticks Order code Type of N auxiliary Qty Wt Operational characteristics


positions contacts per Ambient conditions:
pkg Operating temperature: -25...+60C
NO n [kg] Storage temperature: -40...+70C
Any mounting position is allowed
Without mechanical interlock. Label holder excluded. Degree of protection:
Complete with auxiliary contacts. IP20 for contact elements
8 LM2T J200 2 1 0.082 On front:
Per IEC/EN: IP65
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.

8 LM2T J201 2 1 0.082 Materials


An aluminium and zinc alloy (zama) is used for the metal
parts whereas plastic parts are made of polyamide and
polycarbonate.
8 LM2T J400 4 1 0.104 The sealing boot is made of NBR rubber.

Mechanical endurance
8 LM2T J... Mechanical life: 1,000,000 cycles
without mechanical interlock 8 LM2T J401 4 1 0.104
General characteristics of auxiliary contacts
Self-cleaning with dual effect, scraping and oscillating 6
Rated insulation voltage: 690V
With mechanical interlock in centre position. Rated thermal current Ith: 10A.
Label holder excluded. Complete with auxiliary contacts. Designation acording to IEC 60947-5-1 - A300 Q300.
Operational power in AC15:
8 LM2T J210 2 1 0.082
[V] 12 24 48 120 240
[A] 6 6 6 6 3
Operational power in DC13:
8 LM2T J211 2 1 0.082
[V] 12 24 48 125 250
[A] 0.55 0.55 0.55 0.55 0.27
Short circuit protection fuse: max calibre 10A gG
8 LM2T J410 4 1 0.104 Contact resistance: 20m
Terminals: Clamp screw with washer
Maximum tightening torque: 1Nm
8 LM2T J411 4 1 0.104 Mounting adapter and auxiliary contacts
The joystick is standard supplied with the mounting
8 LM2T J... adapter and auxiliary contacts.
with mechanical interlock The joystick latches onto the mounting adapter by
simple rotation.
The adapter is fixed to the mounting surface by means
of incorporated screws (Tmax = 0.8Nm).
Accessories Order code Description Qty Wt Auxiliary contacts snap onto the mounting adapter.
per Two LM2T CJ... contacts are mounted with the LM2T
pkg J2... types while four on the LM2T J4... versions.
n [kg]
8 LM2T AU101 2-4 directional holder 10 0.004 Certifications and compliance
for adhesive legends Certifications obtained: GOST, CCC; cULus for auxiliary
contacts.
Compliant with standards: IEC/EN 60947-1,
IEC/EN 60947-5-1; UL508 and CSA C22.2 n 14 for
contacts only.

8 LM2T AU101
4

3
2
1
1 2

A A
2

D N
1 N
C
B B

Joystick positions and contact engerising A B C D N A B N


LM2TCJ10 1  1 
LM2TCJ10
2 instable 2 stable LM2TCJ01 2  2 
LM2TCJ10 3 
4 instable 4 stable LM2TCJ01 4 

Accessories Dimensions
page 6-21 page D-33

REV. 02_11
6-10 Control and signalling units electric
Plastic button and selector actuators 22mm

Push-button Order code Colour Qty Wt Operational characteristics


actuators, spring per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
return Storage temperature: -40...+70C
Flush (complete with mounting adapter). Spring return. Any mounting position is allowed
8 LP2T B102 Black 10 0.025 Degree of protection:
8 LP2T B103 Green 10 0.025 Per IEC/EN: IP65
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
8 LP2T B104 Red 10 0.025
8 LP2T B105 Yellow 10 0.025 Materials
Polyamide and polycarbonate.
8 LP2T B106 Blue 10 0.025
8 LP2T B10... 8 LP2T B108 White 10 0.025 Mechanical endurance
Extended (complete with mounting adapter). Spring return. Operating force: 0.8kg (actuator).
Mechanical life: 1,000,000 cycles.
8 LP2T B202 Black 10 0.027
8 LP2T B203 Green 10 0.027 Mounting adapter
8 LP2T B204 Red 10 0.027 Standard supply with the actuator.
Actuators latch onto the mounting adapter by simple
8 LP2T B205 Yellow 10 0.027
rotation.
8 LP2T B206 Blue 10 0.027 The adapter is fixed to the mounting surface by means
6 8 LP2T B20... 8 LP2T B208 White 10 0.027 of incorporated screws (Tmax = 0.6Nm).
Shrouded (complete with mounting adapter). Spring return.
Auxiliary contacts
8 LP2T B302 Black 10 0.027 See page 6-18.
8 LP2T B303 Green 10 0.027 Type: LM2T C10 (1NO)
LM2T CF10 (1NO Faston)
8 LP2T B304 Red 10 0.027
LM2T C10A (EM)
8 LP2T B305 Yellow 10 0.027 LM2T C01 (1NC)
8 LP2T B306 Blue 10 0.027 LM2T CF01 (1NC Faston)
LM2T C01D (LB)
8 LP2T B30... 8 LP2T B308 White 10 0.027
Auxiliary contacts snap onto the mounting adapter.
Up to 6 auxiliary contacts can be fitted on the mounting
adapter: 2 on the left, 2 at the centre and 2 on the right.
Push-button Order code Symbol Colour Qty Wt To mount the auxiliary contacts in the centre position,
per pkg use the accessory: LM2T A140 (see page 6-22).
actuators, spring
return with symbol n [kg]
Flush (complete with mounting adapter). Spring return.
CLICK
8 LP2T B1102 O Black 10 0.025
8 LP2T B1104 Red 10 0.025
8 LP2T B1113 I Green 10 0.025
8 LP2T B1118 White 10 0.025
8 LP2T B1123 II Green 10 0.025
8 LP2T B1128 White 10 0.025
8 LP2T B1132 STOP Black 10 0.025 LM2T A140
8 LP2T B11...
8 LP2T B1134 Red 10 0.025
8 LP2T B1142 Black 10 0.025  The action plug LM2T A140 for the centre position is not standard
 supplied and must be purchased separately.
8 LP2T B1148 White 10 0.025
8 LP2T B1152 Black 10 0.025 Certifications and compliance
 Certifications obtained: cULus, RINA, LROS, GOST, CCC.
8 LP2T B1158 White 10 0.025
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
8 LP2T B1163 START Green 10 0.025 UL508; CSA C22.2 n 14.
8 LP2T B1168 White 10 0.025
8 LP2T B1176 R Blue 10 0.025
8 LP2T B21... 8 LP2T B1178 White 10 0.025
8 LP2T B1196 RESET Blue 10 0.025
8 LP2T B1502 Black 10 0.025
8 LP2T B1512 Black 10 0.025
Extended (complete with mounting adapter). Spring return.
8 LP2T B2102 O Black 10 0.027
8 LP2T B2104 Red 10 0.027
8 LP2T B2132 STOP Black 10 0.027
8 LP2T B2134 Red 10 0.027
 Arrow symbol can be used to indicate right or left.
 Arrow symbol can be used to indicate up or down.

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
electric
Control and signalling units 6-11
Plastic button and selector actuators 22mm

Push-push button Order code Colour Qty Wt Operational characteristics


actuators per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
Storage temperature: -40...+70C
Flush (complete with mounting adapter). Any mounting position is allowed
Push on-push off. Degree of protection:
8 LP2T Q102 Black 10 0.025 Per IEC/EN: IP65 for push-push and
LP2T B654... actuators; IP66 for others.
8 LP2T Q103 Green 10 0.025
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
8 LP2T Q104 Red 10 0.025
8 LP2T Q10... 8 LP2T Q105 Yellow 10 0.025 Materials
Polyamide and polycarbonate.
8 LP2T Q106 Blue 10 0.025
8 LP2T Q108 White 10 0.025 Mechanical endurance
Extended (complete with mounting adapter). Operating force: 0.8 kg (actuator).
Push on-push off. Mechanical life:
Push-push actuators: 500,000 cycles
8 LP2T Q202 Black 10 0.027
Mushroom head buttons: 1,000,000 cycles
8 LP2T Q203 Green 10 0.027 Mushroom head latch buttons: 300,000 cycles.
8 LP2T Q204 Red 10 0.027
8 LP2T Q20... Mounting adapter
8 LP2T Q205 Yellow 10 0.027
Standard supply with the actuator. 6
8 LP2T Q206 Blue 10 0.027 Actuators latch onto the mounting adapter by simple
8 LP2T Q208 White 10 0.027 rotation.
 Use the early-make type, LM2T C10A only. The adapter is fixed to the mounting surface by means
No normally open contact element, 8 LM2T C10, must be used with this of incorporated screws (Tmax = 0.6Nm)
type of button actuators.
A maximum of 2 contact elements can be mounted only. Auxiliary contacts for push-push button actuators
See page 6-18.
Mushroom head Order code Colour Qty Wt Type: LM2T C10A (EM)
per pkg LM2T C01 (1NC)
push-button actuators Auxiliary contacts snap onto the mounting adapter.
n [kg]
Up to 2 auxiliary contacts can be fitted on the mounting
Spring return. 40mm adapter: 1 each on the right and left.
(complete with mounting adapter).
8 LP2T B6142 Black 10 0.033
8 LP2T B6143 Green 10 0.033
8 LP2T B6144 Red 10 0.033
8 LP2T B614...
8 LP2T B6145 Yellow 10 0.033
8 LP2T B6146 Blue 10 0.033
Spring return. 60mm
(complete with mounting adapter).
8 LP2T B6162 Black 10 0.038 Auxiliary contacts for mushroom-head button actuators
See page 6-18.
8 LP2T B6163 Green 10 0.038
Type: LM2T C10 (1NO)
8 LP2T B6164 Red 10 0.038 LM2T CF10 (1NO Faston)
8 LP2T B6165 Yellow 10 0.038 LM2T C10A (EM)
8 LP2T B616...
LM2T C01 (1NC)
8 LP2T B6166 Blue 10 0.038
LM2T CF01 (1NC Faston)
Latch, pull to release. 40mm LM2T C01D (LB)
(complete with mounting adapter). Auxiliary contacts snap onto the mounting adapter
8 LP2T B6242 Black 10 0.097 Up to 4 auxiliary contacts can be fitted on the mounting
adapter with the LP2T B624... and LP2T B6644 types, 2
8 LP2T B6244 Red 10 0.097
on the right and 2 on the left only.
Latch, turn to release. 40mm Up to 6 auxiliary contacts can be fitted on the mounting
8 LP2T B624... (complete with mounting adapter). adapter with all the rest: 2 on the right, 2 at the centre
8 LP2T B6342 Black 10 0.046 and 2 on the left.
To mount the auxiliary contacts in the centre position
8 LP2T B6344 Red 10 0.046
use the accessory: LM2T A140 (see page 6-22).
Latch, turn key to release. 40mm
(complete with mounting adapter).
8 LP2T B6542 Black 10 0.083 CLICK

8 LP2T B6542G 1 0.083


8 LP2T B634...
8 LP2T B6544 Red 10 0.083
8 LP2T B6544G 1 0.083
Latch, turn to release, ISO 13850 (ex EN418) compliant
40mm (complete with mounting adapter).
8 LP2T B6644 Red 10 0.079 LM2T A140

 Versions with different key codes


8 LP2T B654... Complete with the numeric code of the key. The following versions are
available: 501, 502, 503, 504, 505, 506, 507, 508, 509, 510.  The action plug LM2T A140 for the centre position is not standard
Example of complete code: 8 LM2T B6542 G505. supplied and must be purchased separately.

Certifications and compliance


Certifications obtained: cULus, RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
UL508; CSA C22.2 n 14; also IEC/EN 60947-5-5 for
LP2T B6644.
8 LP2T B6644

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
6-12 Control and signalling units electric
Plastic button and selector actuators 22mm

Mechanical reset Order code Colour Qty Wt Operational characteristics


buttons, complete per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
unit, spring return Storage temperature: -40...+70C
Flush (5.2mm stroke). Spring return. Any mounting position is allowed.
Adjustable length 0-140mm max. Degree of protection:
8 LP2T R1002 Black 10 0.038 Per IEC/EN: IP65 for mechanical reset buttons; IP40
8 LP2T R1003 Green 10 0.038 for double and triple-touch actuators.
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K for
8 LP2T R1004 Red 10 0.038 8 LP2T R...; for 8 LP2T B71... and
8 LP2T R1006 Blue 10 0.038 8 LP2T B72... type 1.
8 LP2T R1196 Blue (RESET) 10 0.038
Materials
Extended (5.2mm stroke). Spring return. Polyamide and polycarbonate.
8 LP2T R1196 Adjustable length 0-140mm max.
8 LP2T R2004 Red 10 0.040 Mechanical endurance
Operating force: 0.8kg (actuator).
 With RESET caption on the actuator
Mechanical life: 1,000,000 cycles.

Double-touch Order code Colour Symbols Qty Wt Mounting adapter


actuators, spring per pkg Standard supply with the actuator.
6 n [kg] Actuators latch onto the mounting adapter by simple
return rotation.
Two flush push buttons (complete with mounting adapter). The adapter is fixed to the mounting surface by means
Both spring return. of incorporated screws (Tmax = 0.6Nm).
8 LP2T B7112 Black/Red none 5 0.030
8 LP2T B7113 Green/Red none 5 0.030 Auxiliary contacts for touch actuators
See page 6-18.
8 LP2T B7114 White/Black none 5 0.030 Type: LM2T C10 (1NO)
8 LP2T B7122 Black/Red I-O 5 0.030 LM2T CF10 (1NO Faston)
8 LP2T B7123 Green/Red I-O 5 0.030 LM2T C10A (EM)
LM2T C01 (1NC)
8 LP2T B7124 White/Black I-O 5 0.030 LM2T CF01 (1NC Faston)
8 LP2T B71... 8 LP2T B7133 Green/Red Start/Stop 5 0.030 LM2T C01D (LB)
One extended and one flush push buttons (complete with Auxiliary contacts snap onto the mounting adapter.
mounting adapter). Both spring return.
8 LP2T B7212 Black/Red none 5 0.030
8 LP2T B7213 Green/Red none 5 0.030
8 LP2T B7214 White/Black none 5 0.030
8 LP2T B7222 Black/Red I-O 5 0.030
8 LP2T B7223 Green/Red I-O 5 0.030
8 LP2T B72... 8 LP2T B7224 White/Black I-O 5 0.030
8 LP2T B7233 Green/Red Start/Stop 5 0.030

DOUBLE-TOUCH ACTUATORS
Triple-touch Order code Symbols Qty Wt Up to 4 auxiliary contacts can be fitted on the mounting
actuators, spring per pkg adapter: 2 on the left and 2 on the right.
return n [kg]
Two external flush and one middle extended buttons. TRIPLE-TOUCH ACTUATORS
All spring return. Complete with mounting adapter. Up to 6 auxiliary contacts can be fitted on the mounting
adapter: 2 on the left, 2 in the centre and 2 on the right.
8 LP2T B7345 5 0.028
Certifications and compliance
STOP Certifications obtained: cULus, RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
UL508; CSA C22.2 n 14.

8 LP2T B7355 5 0.028


8 LP2T B73...
STOP

8 LP2T B7365 5 0.028

STOP

8 LP2T B7375 5 0.028

STOP

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
electric
Control and signalling units 6-13
Plastic button and selector actuators 22mm

Selector actuators Order code Type of Qty Wt Operational characteristics


knob positions per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
Storage temperature: -40...+70C
2 position (complete with mounting adapter). Any mounting position is allowed
8 LP2T S120 10 0.037 Degree of protection:
8 LP2T S121 10 0.037 Per IEC/EN: IP65
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
3 position (complete with mounting adapter).
8 LP2T S130 10 0.037 Materials
8 LP2T S1... Polyamide and polycarbonate.
8 LP2T S131 10 0.037
8 LP2T S132 10 0.037 Mechanical endurance
8 LP2T S133 10 0.037 Mechanical life: 300,000 cycles.

Mounting adapter
Selector actuators Standard supply with the actuator.
Order code Type of Qty Wt
Actuators latch onto the mounting adapter by simple
lever positions per pkg
rotation.
n [kg] The adapter is fixed to the mounting surface by means
2 position (complete with mounting adapter). of incorporated screws (Tmax = 0.6Nm).
8 LP2T S220 10 0.037
6
Auxiliary contacts
8 LP2T S221 10 0.037 See page 6-18.
3 position (complete with mounting adapter). Type: LM2T C10 (1NO)
LM2T CF10 (1NO Faston)
8 LP2T S230 10 0.037
LM2T C10A (EM)
8 LP2T S2... 8 LP2T S231 10 0.037 LM2T C01 (1NC)
8 LP2T S232 10 0.037 LM2T CF01 (1NC Faston)
LM2T C01D (LB)
8 LP2T S233 10 0.037
Auxiliary contacts snap onto the mounting adapter.
Up to 4 auxiliary contacts can be fitted on the mounting
adapter: 2 on the left and 2 on the right. For more,
Selector actuators Order code Type of Qty Wt contact our Customer Service (Tel. +39 035 4282422;
key positions per pkg email: service@LovatoElectric.com) for advice.
n [kg]
2 position (complete with mounting adapter).
8 LP2T S320 10 0.060
8 LP2T S320G 1 0.060
8 LP2T S321 10 0.060
8 LP2T S321G 1 0.060 Positions
8 LP2T S340 10 0.060 Stay put position.
8 LP2T S3...
8 LP2T S340G 1 0.060 Spring return position.
3 position (complete with mounting adapter). Key extraction position.
8 LP2T S330 10 0.060
Angles
8 LP2T S330G 1 0.060 2 position 3 position
8 LP2T S331 10 0.060 45 45
90
8 LP2T S331G 1 0.060
8 LP2T S332 10 0.060
8 LP2T S332G 1 0.060 Special versions
8 LP2T S333 10 0.060 Versions with coloured keys are available upon request.
Contact our Customer Service (Tel. +39 035 4282422;
8 LP2T S333G 1 0.060 email: service@LovatoElectric.com).
8 LP2T S350 10 0.060
8 LP2T S350G 1 0.060 Certifications and compliance
Certifications obtained: cULus, RINA, LROS, GOST, CCC.
8 LP2T S360 10 0.060 Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
8 LP2T S360G 1 0.060 UL508; CSA C22.2 n 14.
8 LP2T S370 10 0.060
8 LP2T S370G 1 0.060
8 LP2T S380 10 0.060
8 LP2T S380G 1 0.060
8 LP2T S390 10 0.060
8 LP2T S390G 1 0.060
 Versions with different key codes.
Complete with the numeric code of the key. The following versions are
available: 501, 502, 503, 504, 505, 506, 507, 508, 509, 510.
Example of complete code: 8 LP2T S320 G505.
 Available only on specific request.

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
6-14 Control and signalling units electric
Plastic button and selector actuators 22mm

Illuminated button Order code Colour Qty Wt Operational characteristics


actuators, spring per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
return Storage temperature: -40...+70C
Flush (with side visibility) (complete with mounting adapter). Any mounting position is allowed
Spring return. Degree of protection:
8 LP2T BL103 Green 10 0.025 Per IEC/EN: IP65
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
8 LP2T BL104 Red 10 0.025
8 LP2T BL105 Yellow 10 0.025 Materials
Polyamide and polycarbonate.
8 LP2T BL106 Blue 10 0.025
Mechanical endurance
8 LP2T BL107 Transparent 10 0.025
8 LP2T BL10... Operating force: 0.8kg (actuator).
Extended (complete with mounting adapter). Mechanical life: 500,000 cycles for push-push actuators;
Spring return. 1,000,000 cycles for others.
8 LP2T BL203 Green 10 0.027 Mounting adapter
8 LP2T BL204 Red 10 0.027 Standard supply with the actuator.
8 LP2T BL205 Yellow 10 0.027 Actuators latch onto the mounting adapter by simple
rotation.
8 LP2T BL206 Blue 10 0.027 The adapter is fixed to the mounting surface by means
6 8 LP2T BL20...
8 LP2T BL207 Transparent 10 0.027 of incorporated screws (Tmax = 0.6Nm).
Auxiliary contacts for illuminated push-push actuators:
See page 6-18.
Push-push button Order code Colour Qty Wt Type: LM2T C10A (EM)
actuators per pkg LM2T C01 (1NC)
n [kg] Auxiliary contacts snap onto the mounting adapter.
Up to 2 auxiliary contacts can be fitted on the mounting
Flush (complete with mounting adapter).
adapter in a row, 1 each on the right and left, along with
Push on-push off.
the lamp-holder in the centre position, of which
8 LP2T QL103 Green 10 0.025 LM2T EL400, LM2T ZL230, LM2T L... or LM2T M... (see
8 LP2T QL104 Red 10 0.025 page 6-19).
With lamp-holder LM2T YL... or LM2T GL..., one
8 LP2T QL105 Yellow 10 0.025
auxiliary contact can be mounted only (see page 6-19).
8 LP2T QL106 Blue 10 0.025
8 LP2T QL10... Auxiliary contacts for illuminated button or mushroom-
8 LP2T QL107 Transparent 10 0.025 head actuators
Extended (complete with mounting adapter). See page 6-18.
Push on-push off. Type: LM2T C10 (1NO)
8 LP2T QL203 Green 10 0.027 LM2T CF10 (1NO Faston)
LM2T C10A (EM)
8 LP2T QL204 Red 10 0.027 LM2T C01 (1NC)
8 LP2T QL205 Yellow 10 0.027 LM2T CF01 (1NC Faston)
8 LP2T QL206 Blue 10 0.027 LM2T C01D (LB)
Auxiliary contacts snap onto the mounting adapter.
8 LP2T QL20... 8 LP2T QL207 Transparent 10 0.027 On LP2T BL1, LP2T BL2 or LP2T BL61 actuators, the
 Use the early-make type, LM2T C10A only. following can be fitted on the mounting adapter:
No normally open contact element, 8 LM2T C10, must be used with this
Up to 4 contacts, 2 each on the left and right, when
type of button actuators.
A maximum of 2 contact elements can be mounted only. one of the following lamp-holders is used:
LM2T DL400, LM2T EL400, LM2T VL230,
LM2T ZL230, LM2T L or LM2T M (see page 6-19).
Illuminated Order code Colour Qty Wt Up to 2 contacts, one on top of the other of the same
mushroom head per pkg type only, when one of the following lamp-holders is
n [kg] used LM2T XL, LM2T YL, LM2T FL or LM2T GL (see
button actuators page 6-19).
Spring return. 40mm (complete with mounting adapter). On LP2T BL62... actuator, the following can be fitted on
8 LP2T BL6143 Green 10 0.035 the mounting adapter:
8 LP2T BL6144 Red 10 0.035 Up to 2 contacts, 1 each on the right and left, when
one of the following lamp-holders is used
8 LP2T BL6145 Yellow 10 0.035 LM2T DL400, LM2T EL400, LM2T VL230,
8 LP2T BL6146 Blue 10 0.035 LM2T ZL230, LM2T L or LM2T M (see page 6-19)
8 LP2T BL6148 White 10 0.035 Up to 2 contacts, one on top of the other of the same
8 LP2T BL614... type only, when one of the following lamp-holders is
Latch, pull to release 40mm (complete with mounting used: LM2T XL, LM2T YL, LM2T FL or LM2T GL (see
adapter). page 6-19).
8 LP2T BL6243 Green 10 0.040
8 LP2T BL6244 Red 10 0.040
8 LP2T BL6245 Yellow 10 0.040
8 LP2T BL6246 Blue 10 0.040
8 LP2T BL6248 White 10 0.040
 The number of auxiliary contacts to be mounted is given in the side
notes. Lamp-holder elements
 A maximum of 2 auxiliary contacts can be mounted only. See page 6-19 and 20.
8 LP2T BL624... Bulbs
Maximum recommended power: 1.2W.
See page 6-22.
Certifications and compliance
Certifications obtained: cULus, RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1,
IEC/EN 60947-5-1; UL508; CSA C22.2 n 14.

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
electric
Control and signalling units 6-15
Plastic button and selector actuators 22mm

Double touch Orde code Colour Symbol Qty Wt Operational characteristics


actuators, spring per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
return with white Storage temperature: -40...+70C
Two flush push-buttons (complete with mounting adapter).
indicator Both spring return.
Any mounting position is allowed
Degree of protection:
8 LP2T BL7112 Black/Red none 5 0.028 Per IEC/EN: IP65 for selectors;
8 LP2T BL7113 Green/Red none 5 0.028 IP40 for double-touch actuators.
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K except for
8 LP2T BL7114 White/Black none 5 0.028 8 LP2T BL71... and 8 LP2T BL72... which are type 1.
8 LP2T BL7122 Black/Red I-O 5 0.028
8 LP2T BL7123 Green/Red I-O 5 0.028 Materials
Polyamide and polycarbonate.
8 LP2T BL7124 White/Black I-O 5 0.028
8 LP2T BL711... 8 LP2T BL721... 8 LP2T BL7133 Green/Red Start/Stop 5 0.028 Mechanical endurance
One extended push-button (complete with mounting adapter). Operating force: 0.8kg (actuator).
Both spring return. Mechanical life for push-buttons: 1,000,000 cycles.
8 LP2T BL7212 Black/Red none 5 0.028 Mounting adapter of double-touch actuators
8 LP2T BL7213 Green/Red none 5 0.028 Standard supply with the actuator.
Actuators latch onto the mounting adapter by simple
8 LP2T BL7214 White/Black none 5 0.028
rotation. 6
8 LP2T BL7222 Black/Red I-O 5 0.028 The adapter is fixed to the mounting surface by means of
8 LP2T BL7223 Green/Red I-O 5 0.028 incorporated screws (Tmax = 0.6Nm).
LM2T A12...
8 LM2TA12... 8 LP2T BL7224 White/Black I-O 5 0.028
Auxiliary contacts
8 LP2T BL7233 Green/Red Start/Stop 5 0.028 See page 6-18.
Type: LM2T C10 (1NO)
LM2T CF10 (1NO Faston)
LM2T C10A (EM)
LM2T C01 (1NC)
The actuator is standard supplied with a white LM2T CF01 (1NC Faston)
diffuser. Coloured diffusers LM2T A12... can be LM2T C01D (LB)
purchased separately. Refer to page 6-20. DOUBLE-TOUCH ACTUATORS
Up to 4 auxiliary contacts can be fitted on the mounting
Illuminated Orde code Colour Type of Qty Wt adapter: 2 on the left and 2 on the right.
positions per pkg SELECTOR ACTUATORS
selector actuators On 2-position illuminated selectors, the following can be
n [kg] fitted on the mounting adapter:
2 position (complete with mounting adapter). Up to 4 auxiliary contacts when the following types of
8 LP2T SL1203 Green 10 0.025 lamp-holders are used: LM2T EL400, LM2T ZL230,
LM2T L... or LM2T M... (see page 6-19).
8 LP2T SL1204 Red 10 0.025 Up to 2 auxiliary contacts when the following types of
8 LP2T SL1205 Yellow 10 0.025 lamp-holders are used: LM2T YL... or LM2T GL... (see
8 LP2T SL1206 Blue 10 0.025 page 6-19).
On 3-position illuminated selectors, the following can be
8 LP2T SL1208 White 10 0.025 fitted on the mounting adapter:
8 LP2T SL1... 8 LP2T SL1213 Green 10 0.025 Up to 4 auxiliary contacts when the types of
8 LP2T SL1214 Red 10 0.025 lamp-holders are used: LM2T EL400, LM2T ZL230,
LM2T L... or LM2T M... (see page 6-19).
8 LP2T SL1215 Yellow 10 0.025 NOTE: The LM2T YL... or LM2T GL... lamp-holders cannot
8 LP2T SL1216 Blue 10 0.025 be mounted.
8 LP2T SL1218 White 10 0.025
Selector positions
3 position (complete with mounting adapter).
8 LP2T SL1303 Green 10 0.025 Stay put position.
8 LP2T SL1304 Red 10 0.025 Spring return position.
8 LP2T SL1305 Yellow 10 0.025 Selector angles
8 LP2T SL1306 Blue 10 0.025 2 position 3 position
45 45
8 LP2T SL1308 White 10 0.025 90
8 LP2T SL1313 Green 10 0.025
8 LP2T SL1314 Red 10 0.025
8 LP2T SL1315 Yellow 10 0.025 Lamp-holder elements for selectors
8 LP2T SL1316 Blue 10 0.025 See page 6-19.
8 LP2T SL1318 White 10 0.025 Lamp-holder elements for double touch actuators
8 LP2T SL1323 Green 10 0.025 Use lamp-holder type LM2T EL400, LM2T ZL230,
8 LP2T SL1324 Red 10 0.025 LM2T GL..., LM2T L... or LM2T M... See page 6-19.
8 LP2T SL1325 Yellow 10 0.025 Bulbs
8 LP2T SL1326 Blue 10 0.025 Maximum recommended power: 1.2W.
8 LP2T SL1328 White 10 0.025 See page 6-22.
8 LP2T SL1333 Green 10 0.025 Certifications and compliance
8 LP2T SL1334 Red 10 0.025 Certifications obtained: cULus, RINA, LROS, GOST, CCC.
8 LP2T SL1335 Yellow 10 0.025 Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
UL508; CSA C22.2 n 14.
8 LP2T SL1336 Blue 10 0.025
8 LP2T SL1338 Whiite 10 0.025

Add-on-blocks Accessories and spare parts Dimensions


pages 6-18 and 20 pages 6-21 to 23 page D-32

REV. 02_11
6-16 Control and signalling units electric
Pilot lights

LED integrated Order code Rated auxiliary LED Qty Wt Operational characteristics
monoblock pilot supply voltage colour per pkg Rated auxiliary supply voltage Us: 12VAC/DC, 24VAC/DC;
n [kg] 110VAC; 230VAC
lights, steady light Operating range: -15...+10% Us
Screw terminals with protection. Lamp supplied. Electrical life: >30,000 hours
8 LP2T ILA3 12VAC/DC Green 10 0.021 Consumption: 20mA
8 LP2T ILA4 Red 10 0.021 Screw termination
Maximum tightening torque: 0.8Nm
8 LP2T ILA5 Yellow 10 0.021 Side cable entry
8 LP2T ILA6 Blue 10 0.021 Ambient conditions:
8 LP2T ILA8 Transparent 10 0.021 Operating temperature: -5...+40C
8 LP2T IL...
Degree of protection: IP65 on front; IP20 at rear.
8 LP2T ILB3 24VAC/DC Green 10 0.021
8 LP2T ILB4 Red 10 0.021 Materials
Polyamide and polycarbonate.
8 LP2T ILB5 Yellow 10 0.021
8 LP2T ILB6 Blue 10 0.021 Maximum conductor cross section
1 or 2 1.5mm2 or 16 AWG cables.
8 LP2T ILB8 Transparent 10 0.021
8 LP2T ILE3 110VAC Green 10 0.024 Wiring diagram
LED
8 LP2T ILE4 Red 10 0.024
6 8 LP2T ILE5 Yellow 10 0.024
X1 X2

8 LP2T ILE6 Blue 10 0.024 Certifications and compliace


Certifications obtained: cULus, GOST and CCC.
8 LP2T ILE8 Transparent 10 0.024 Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
8 LP2T ILM3 230VAC Green 10 0.024 UL508; CSA C22.2 n 14.
8 LP2T ILM4 Red 10 0.024
8 LP2T ILM5 Yellow 10 0.024
8 LP2T ILM6 Blue 10 0.024
8 LP2T ILM8 Transparent 10 0.024

Monoblock pilot Order code Colour Lamp Qty Wt Operational characteristics


lights (with supplied per pkg Ambient conditions:
n [kg] Operating temperature: -25...+60C
diffuser) Storage temperature: -40...+70C
Screw terminals without protection. Lamp not supplied. Any mounting position is allowed
8 LP2T IL213 Green no 10 0.023 Degree of protection:
8 LP2T IL214 Red no 10 0.023 Per IEC/EN: IP65 on front; IP20 at rear
Per UL: type 1, 2, 3R, 4, 4X, 12, 12K.
8 LP2T IL215 Yellow no 10 0.023
Materials
8 LP2T IL216 Blue no 10 0.023 Polyamide and polycarbonate.
8 LP2T IL21...
8 LP2T IL217 Transparent no 10 0.023 Maximum conductor cross section
Screw terminals with protection. Lamp not supplied. 1 or 2 1.5mm2 or AWG16 cables.
8 LP2T IL223 Green no 10 0.024 Wiring diagram
X1 X2
8 LP2T IL224 Red no 10 0.024 Bulbs
8 LP2T IL225 Yellow no 10 0.024 Max rated auxiliary supply voltage: 415VAC/DC
8 LP2T IL226 Blue no 10 0.024 Maximum recommended power: 2.6W. See page 6-22.
8 LP2T IL22...
8 LP2T IL227 Transparent no 10 0.024
LM2T A180
Faston terminals without protection. Lamp not supplied.
8 LP2T IL233 Green no 10 0.021
8 LP2T IL234 Red no 10 0.021 LM2T AL...
8 LP2T IL235 Yellow no 10 0.021
8 LP2T IL23... 8 LP2T IL236 Blue no 10 0.021 LM2T AT...

8 LP2T IL237 Transparent no 10 0.021


 LP2T IL23... pilot lights have Faston terminals, 1-6.35 or 2-2.8mm.. LM2T A190

 Can be purchased separately.


Refer to pages 6-22 and 23.
 Standard supplied with LP2T IL22... only..

Certifications and compliance


Certifications obtained: cULus, (8 LP2T IL23 UL
Recognized), RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
UL508; CSA C22.2 n 14.

Accessories and spare parts Dimensions


pages 6-21 to 23 pages D-32 and 33

REV. 02_11
electric
Control and signalling units 6-17
Monoblock buzzers.
Control stations

Pulse-tone Order code Voltage Sound Qty Weight General characteristics


monoblock buzzers intensity per Monoblock buzzers are used as sound indicators in
at 2500Hz pkg automation systems and on-board machinery in the
[V] [dB] n [kg] production processes,
Pulse-tone. Long life, low consumption values and compact size are
the main features of this product.
8 LP2T ZGB 24VAC/DC 80dB 10 0.020
8 LP2T ZGE 110VAC/DC 10 0.020 Operational characteristics
8 LP2T ZGM 230VAC 10 0.020 Rated auxiliary supply voltage: 24VAC/DC;
110VAC/DC; 230VAC
8 LP2T ZG...  Value measured at a distance of 10cm. Operating voltage: 50-60Hz
Consumption: <20mA
Pulse-tone sound graph Service life: 30,000 hours (permanently powered)
Screw termination
Hz
Maximum tightening torque: 0.8Nm
3500
Side cable entry
3000 Ambient conditions:
0.6s 0.2s 0.6s 0.2s 0.6s Operating temperature: -25...+55C
2500 Storage temperature: -25...+55C
Degree of protection:
2000

1500
IP40 on front
IP20 at rear.
6
1000 Materials
Polyamide and polycarbonate.
500

0 s Maximum conductor cross section


0 0.8 1.4 2 1 or 2 2.5mm2 or AWG12 cables.
0.6 1 1.6 2.2
Wiring diagram
X1

X2

Reference standards
Comply with standards: IEC/EN 60947-1,
IEC/EN 60947-5-1, IEC/EN 61000-6-1, IEC/EN 61000-6-3.

Empty control Order code Description Cover Qty Wt General characteristics


station enclosures colour per pkg Control stations have cable entry through the top or the
n [kg] bottom and come fitted with a conduit (21.3mm entry
diameter).
8 L2PP 1A5 For 1 actuator Yellow 1 0.138 Complete control stations are supplied assembled and
8 L2PP 1A8 For 1 actuator White 1 0.138 complete with the indicated push-button actuator, mounting
8 L2PP 2A8 For 2 actuators White 1 0.198 adapter, legend holder, STOP label (except for L2PP 115,
L2PP 130, L2PP 165 and L2PP 180) and one NC auxiliary
8 L2PP 3A8 For 3 actuators White 1 0.213 contact.
8 L2PP 4A8 For 4 actuators White 1 0.253
8 L2PP 5A8 For 5 actuators White 1 0.275 Operational characteristics
8 L2PP 2A8 Degree of protection: IP65 using adequate cable glands,
not included in the supply. IP52 for L2PP 5A8 only.
Tightening torque of cover fixing screws: 0.8Nm.
Ambient conditions:
Operating temperature: -25...+60C
Storage temperature: -40...+70C

Materials
Complete control Order code Description Qty Wt Self-extinguishing ABS plastic.
stations Enclosure + actuator per pkg
n [kg] Certifications and compliance
8 L2PP 100 8 L2PP 1A8 + 8 LP2T B6244 1 0.264 Certifications obtained: GOST, CCC; also cULus for
empty enclosures.
8 L2PP 110 8 L2PP 1A8 + 8 LP2T B6344 1 0.213 Compliant with standards: IEC/EN 60947-1,
8 L2PP 115 8 L2PP 1A5 + 8 LP2T B6344 1 0.213 IEC/EN 60947-5-1, also UL508A and CSA C22.2 n 14
8 L2PP 120 8 L2PP 1A8 + 8 LP2T B6544 1 0.250 for empty types.
8 L2PP 130 8 L2PP 1A5 + 8 LP2T B6644 1 0.244
8 L2PP 150 8 L2PP 1A8 + 8 LM2T B6244 1 0.291
8 L2PP 160 8 L2PP 1A8 + 8 LM2T B6344 1 0.240
8 L2PP 160 8 L2PP 165 8 L2PP 1A5 + 8 LM2T B6344 1 0.240
8 L2PP 170 8 L2PP 1A8 + 8 LM2T B6544 1 0.277
8 L2PP 180 8 L2PP 1A5 + 8 LM2T B6644 1 0.271
 Red mushroom head, turn to release, yellow cover ISO13850 (ex EN418)
compliant, no label and no label holder.

Accessories and spare parts Dimensions Wiring diagrams


pages 6-21 to 23 page D-33 page W-11

REV. 02_11
6-18 Control and signalling units electric
Add-on elements for buttons and selectors

Mounting adapter Order code Description Qty Operational characteristics


per Wt Ambient conditions:
pkg Operating temperature: -25...+60C
Storage temperature: -40...+70C
n [kg] Any mounting position is allowed
Only for metal series actuators. Degree of protection:
8 LM2T AU120 Mounting adapter 10 0.019 IP20 for contacts elements with screw termination
IP00 for contact elements with Faston termination.
Metal series actuators are supplied without mounting adapter.
Plastic series actuators are supplied complete with mounting General characteristics of the auxiliary contacts
8 LM2T AU120 adapter (type LP2T AU120). Self-cleaning with dual effect, scraping and oscillating
Rated insulation voltage: 690V
Rated thermal current Ith: 10A
Designation according to IEC 60947-5-1: A600 Q600
Operational power in AC15:
[V] 12 24 48 120 240 400 480 500 600
Contact elements Order code Function Qty Wt [A] 6 6 6 6 3 1.9 1.5 1.4 1.2
per Operational power in DC13:
pkg [V] 12 24 48 125 250 440 500 600
n [kg] [A] 3 3 1.5 0.55 0.27 0.15 0.13 0.1
Short-circuit protection fuse: max. calibre 10A gG
Screw termination. Contact resistance: 20m
6 Without mounting adapter. Terminals: Clamp screw with washer
.3
8 LM2T C10 10 0.011 Faston 1-6.35mm or 2-2.8mm
NO Maximum tightening torque: 1Nm (Faston excluded).
.4
.7
8 LM2T C10A 10 0.011 Stroke of auxiliary contacts
EM EM
8 LM2T C... .8
.1 NO
8 LM2T C01 10 0.011
NC NC
.2 LB
8 LM2T C01D .5 10 0.011 1 2 3 4 4.8 mm
LB 1.8 2.8
.6
Screw termination. Closed contact Open contact
With mounting adapter for actuators metal series LM2T... only.
.3
Maximum conductor section for screw termination
8 LM2T E10 10 0.029 1 or 2 2.5 mm2 or AWG12 cables.
NO
.4
8 LM2T E... 8 LM2T E01 .1
10 0.029 Mechanical and electrical endurance
NC Operating force: 0.5 kg (auxiliary contacts).
.2 Electrical life: LM2T C10 1,000,000 cycles
Faston termination. LM2T CF10 1,000,000 cycles
Without mounting adapter. LM2T C01 1,000,000 cycles
8 LM2T CF10 .3
10 0.012 LM2T CF01 1,000,000 cycles
NO LM2T C10A 600,000 cycles
.4 LMET C01D 600,000 cycles
.1
8 LM2T CF01 10 0.012 50

NC
.2
22.5
42.4

 Not suitable for push-push actuators. Use LM2T C10A (EM) or LM2T
C01 (NC) type only with push-push actuators.
 Normally open contact with early make operation.
 Direct opening operation in accordance with IEC/EN 60947-5-1. 30

8 LM2T CF01  Normally closed contact with late break operation.


65

 When using Faston, vertical interaxes is 90mm minimum.


Certifications and compliance
Certifications obtained: cULus, RINA, LROS, GOST, CCC.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
UL508; CSA C22.2 n 14.

8 LM2T CF10

Accessories and spare parts Dimensions Wiring diagrams


pages 6-21 to 23 pages D-32 and 33 page W-11

REV. 02_11
electric
Control and signalling units 6-19
Add-on elements for buttons and selectors

Lamp-holders Order code Rated Type of Qty Wt Operational characteristics


without mounting auxiliary bulb per Ambient conditions:
supply voltage supplied pkg Operating temperature: -25...+60C
adapter [V] 50/60Hz n [kg] Storage temperature: -40...+70C
Any mounting position is allowed
For actuators of plastic and metal series. Tightening torque: 1Nm
Supplied without mounting adapter. Direct supply. Degree of protection: IP20.
8 LM2T EL400 415VAC/DC No 10 0.011
With resistor and diode. Maximum conductor section
8 LM2T ZL230 230VAC Yes 10 0.015 1 or 2 2.5mm2 or AWG12 cables.
130V, 2W
Wiring diagram
With transformer. Direct supply With resistor and diode
8 LM2T YL110 110-120VAC Yes 1 0.086 LM2T EL400 X1 LM2T ZL230 X1

8 LM2T EL400 8 LM2T YL... 24V, 1.2W LM2T DL400 LM2T VL230
X2
8 LM2T ZL230 8 LM2T GL... 8 LM2T YL230 220-240VAC Yes 1 0.084 X2

24V, 1.2W With transformer Flashing


LM2T YL... X1 LM2T GL... X1
8 LM2T YL400 380-415VAC Yes 1 0.087 LM2T XL... LM2T FL...
24V, 1.2W X2 X2

Flashing. Test element


LM2T T100
X1
X5
6
8 LM2T GL048 24-48VAC No 1 0.027 TEST

8 LM2T GL230 110-230VAC No 1 0.027


8 LM2T T100 Test element for famp-holders.
8 LM2T T100 Test element  10 0.011

Lamp-holders with Order code Rated Type of Qty Wt


mounting adapter auxiliary bulb per
supply voltage supplied pkg
[V] 50/60Hz n [kg]
Only for actuators of metal series.
Supplied complete with mounting adapter. Direct supply. Certifications and compliance
Certifications obtained: cULus, RINA, LROS, GOST, CCC.
8 LM2T DL400 415VAC/DC No 10 0.029 Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
With resistor and diode. UL508; CSA C22.2 n 14.
8 LM2T VL230 230VAC Yes 10 0.032
8 LM2T DL400 - 8 LM2T VL230
130V, 2W
With transformer.
8 LM2T XL110 110-120VAC Yes 1 0.105
24V, 1.2W
8 LM2T XL230 220-240VAC Yes 1 0.103
24V, 1.2W
8 LM2T XL400 380-415VAC Yes 1 0.106
24V, 1.2W
Flashing.
8 LM2T XL... - 8 LM2T FL...
8 LM2T FL048 24-48VAC No 1 0.046
8 LM2T FL230 110-230VAC No 1 0.046
 Filament bulb, BA9s U130VAC/DC max 2.6W (not supplied); maximum
dimensions 11x28 mm. For higher voltages, use neon bulbs.
 Not suitable for 3-position selectors.
 Filament bulb, BA9s (not supplied); maximum dimensions 11x28mm.
Suitable for AC duty only.
Use bulbs with rated voltage equal to that of the power supply.
E.g.: With LM2T FL230 use 110VAC bulbs if power supply is 110VAC and
230VAC bulbs if power supply 230VAC. 2.6W max bulb rating.
 MultiLED bulbs must not be fitted.
 In case of test circuits for lamp-holders having load in parallel, two LM2T
T100 elements are required for each bulb.
Refer to the wiring diagram attached to the product or contact our Customer
Service (Tel. +39 035 4282422; email: service@LovatoElectric.com).
 In case of neon bulbs, contact our Customer Service
(Tel. +39 035 4282422; email: service@LovatoElectric.com).
Luminosity is reduced during testing of lamp-holder LM2T L... and
LM2T M... types.

Accessories and spare parts Dimensions Wiring diagrams


pages 6-21 to 23 page D-32 and 33 page W-11

REV. 02_11
6-20 Control and signalling units electric
Add-on elements for buttons and selectors

LED integrated Order code Rated aux LED Qty Wt Operational characteristics
lamp-holder steady for steady supply colour per Rated auxiliary supply voltage: 18-30VAC/DC;
light voltage pkg 85-140VAC; 187-265VAC
or flashing light [V] n [kg] Maximum consumption: 33mA for 18-30VAC/DC;
28mA for 85-140VAC; 25mA for 187-265VAC
For metal and plastic actuators. Electric life: 100,000 hours
Supplied without mounting adapter. Ambient conditions:
8 LM2T LB3 18-30V Green 10 0.016 Operating temperature: -25...+60C
8 LM2T LB4 AC/DC Red 10 0.016 Storage temperature: -40...+70C
Any mounting position is allowed
8 LM2T LB5 Yellow 10 0.016 Tightening torque: 1Nm
8 LM2T LB6 Blue 10 0.016 Degree of protection: IP20.
8 LM2T LB8 White 10 0.016
Maximum conductor section
8 LM2T LE3 85-140V Green 10 0.016 1 or 2 2.5mm2 or AWG12 cables.
8 LM2T LM3 8 LM2T LE4 AC Red 10 0.016
8 LM2T LE5 Yellow 10 0.016 Wiring diagram
LED
8 LM2T LE6 Blue 10 0.016 X1 X2
8 LM2T LE8 White 10 0.016
Certifications and compliance
6 8 LM2T LM3 187-265V
AC
Green 10 0.016
Certfications obtained: cULus, GOST, CCC.
8 LM2T LM4 Red 10 0.016 Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1;
8 LM2T LM5 Yellow 10 0.016 UL508; CSA C22.2 n 14.
8 LM2T LM6 Blue 10 0.016
8 LM2T LM8 White 10 0.016
 Steady-light 9-15VAC/DC types are available on request; contact our
Customer Service (Tel +39 035 4282422;
email: service@LovatoElectric.com).

Luminosity is reduced during test with test element LM2T T100.

Order code Rated aux LED Qty Wt


for flashing supply colour per
light voltage pkg
[V] n [kg]
For metal and plastic actuators.
Supplied without mounting adapter.
8 LM2T MB3 18-30V Green 10 0.016
8 LM2T MB4 AC/DC Red 10 0.016
8 LM2T MB5 Yellow 10 0.016
8 LM2T MB6 Blue 10 0.016
8 LM2T MB8 White 10 0.016
8 LM2T ME3 85-140V Green 10 0.016
8 LM2T ME4 AC Red 10 0.016
8 LM2T ME5 Yellow 10 0.016
8 LM2T ME6 Blue 10 0.016
8 LM2T ME8 White 10 0.016
8 LM2T MM3 187-265V Green 10 0.016
8 LM2T MM4 AC Red 10 0.016
8 LM2T MM5 Yellow 10 0.016
8 LM2T MM6 Blue 10 0.016
8 LM2T MM8 White 10 0.016

Luminosity is reduced during test with test element LM2T T100.

Accessories and spare parts Dimensions Wiring diagrams


pages 6-21 to 23 page D-32 page W-11

REV. 02_11
electric
Control and signalling units 6-21
Accessories for buttons and selectors

Labels with text for Ordering code Text Qty per Wt General characteristics
LM2T AU100 pkg The labels have indelible scratch-proof black lettering on
n [kg] metalised grey polycarbonate background (adhesive).
legend holder
General use. Special versions
8 LM2T AU206 Blank for writing 50 0.001 Labels in different languages are available.
8 LM2T AU207 Sheet with 108 labels 1 0.005 Contact our Customer Service (Tel. +39 035 4282422;
for laser printing email: service@LovatoElectric.com).
8 LM2T AU208 Sheet with 108 1 0.005
laser-printed labels
8 LM2T AGB230
8 LM2T AGB216 CLOSE 50 0.001
8 LM2T AGB220 EMERGENCY 50 0.001
8 LM2T AGB231 FAST 50 0.001
8 LM2T AGB263 FAULT 50 0.001
8 LM2T AGB215 FORWARD 50 0.001
8 LM2T AGB228 LEFT 50 0.001
8 LM2T AGB218 LOWER 50 0.001
8 LM2T AGB221 OFF 50 0.001 6
8 LM2T AGB223 ON 50 0.001
8 LM2T AGB211 OPEN 50 0.001
8 LM2T AGB229 POWER ON 50 0.001
8 LM2T AGB227 RAISE 50 0.001
8 LM2T AGB226 RESET 50 0.001
8 LM2T AGB222 REVERSE 50 0.001
8 LM2T AGB217 RIGHT 50 0.001
8 LM2T AGB241 RUNNING 50 0.001
8 LM2T AGB224 SLOW 50 0.001
8 LM2T AGB225 START 50 0.001
8 LM2T AGB230 STOP 50 0.001
8 LM2T AGB214 STOP RESET 50 0.001
8 LM2T AGB240 THERMAL FAULT 50 0.001
8 LM2T AGB237 TRIP 50 0.001
For selector switches.
8 LM2T AI233 AUTO-MAN 50 0.001
8 LM2T AI234 AUTO-O-MAN 50 0.001
8 LM2T AI241 MAN-AUTO 50 0.001
8 LM2T AI242 MAN-O-AUTO 50 0.001
8 LM2T AGB235 FWD-O-REV 50 0.001
8 LM2T AGB236 OFF-ON 50 0.001
8 LM2T AGB232 STOP-START 50 0.001
International labels for push-buttons.
8 LM2T AU200 O 50 0.001
8 LM2T AU201 I 50 0.001
8 LM2T AU202 II 50 0.001
International labels for selector switches.
8 LM2T AU203 O-I 50 0.001
 Recommended use with LM2T AU206 blank label. 8 LM2T AU204 I-II 50 0.001
 Sheet with 108 adhesive labels. 8 LM2T AU205 I-O-II 50 0.001
Complete code with label text required.

Plastic disks for Ordering code Text Qty per Wt General characteristics
pkg The disks are made of non-adhesive plastic.
mushroom-head There is a 2x2mm index.
push-buttons n [kg]
8 LM2T AU113 EMERGENCY STOP 10 0.005 Special versions
ERGENCY
90mm The disk text in different languages is available.
EM Contact our Customer Service (Tel. +39 035 4282422;
8 LM2T AU115 EMERGENCY STOP 10 0.005
60mm email: service@LovatoElectric.com).
8 LM2T AU118 NOT AUS / 10 0.005
ARRET DURGENCE /
PARO EMERGENCIA
STOP
60MM

Accessories and spare parts Dimensions


page 6-23 page D-33

REV. 02_11
6-22 Control and signalling units electric
Accessories and spare parts for
buttons and selectors

Accessories and Order code Description Qty per Wt


spare parts pkg
LM2T AU100
n [kg] CLICK
LM2T AU105
8 LM2T A12 Coloured diffuser for 10 0.001
double push-buttons
8 LM2T A130 Threaded plug for 10 0.007 LM2T AU170
unused holes
8 LM2T A140 Action plug for centre 50 0.001
8 LM2T A130 contact
LM2T AU120
8 LM2T A150 Rod for mechanical 10 0.006 LP2T AU120
reset button LM2T A140
(l=140mm max)
8 LM2T A160 BA9s bulb extractor 10 0.004
8 LM2T A161 30mm hole size adapter 10 0.002
for 22mm (2 per hole)
8 LM2T A140 8 LM2T A170 Spare key set for 1 0.008
selector or mushroom
head button LM2T A180
6 8 LM2T A170G Spare key set for 1 0.008
G series selector or
mushroom-head button
LM2T AT...
8 LM2T A180 IP20 terminal protection 10 0.002 LM2T AU170
8 LM2T A180 for monoblock pilot light
LP2T IL2...
8 LM2T A185 Selector protection 10 0.004
LM2T AL...
shroud (for knob
types only)
8 LM2T A190 Diffuser for pilot light 10 0.003 LM2T A190

8 LM2T ALA024 Filament bulb BA9s 50 0.002


24VAC/DC -
8 LM2T A185 1.2W 10x28mm
8 LM2T ALB024 Filament bulb BA9s 50 0.003
24VAC/DC -
2W 10x28mm
8 LM2T ALB048 Filament bulb BA9s 50 0.003
8 LM2T AL... 48VAC/DC -
2W 10x28mm
8 LM2T ALB130 Filament bulb BA9s 50 0.003
130VAC/DC -
2W 10x28mm
8 LM2T ALL006 MultiLED bulb BA9s 10 0.003
6VAC/DC 10x28mm
8 LM2T ALL024 MultiLED bulb BA9s 10 0.003
24VAC/DC 10x28mm
8 LM2T ALL048 MultiLED bulb BA9s 10 0.003
48VAC/DC 10x28mm
8 LM2T ALN130 Neon bulb  BA9s 50 0.003
110/125VAC 10x28mm
8 LM2T ALN250 Neon bulb  BA9s 50 0.003
220/250VAC 10x28mm
8 LM2T ALN400 Neon bulb  BA9s 50 0.003
380/400VAC 10x28mm
8 LM2T ALP130 Neon bulb  BA9s 50 0.003
110/125VAC 10x28mm
8 LM2T ALP250 Neon bulb  BA9s 50 0.003
 Add the digit of the selected colour: 3 (green); 220/250VAC 10x28mm
4 (red); 5 (yellow); 6 (blue); 7 (transparent); 8 LM2T ALP400 Neon bulb  BA9s 50 0.003
8 (white).
 Versions with different key code. Complete with the 380/400VAC 10x28mm
numeric code of the key. The following versions
are available: 501, 502, 503, 504,
505, 506, 507, 508, 509, 510.
Example of complete code: 8 LM2T A170G505.
Coloured key versions are available on request;
contact our Customer Service
(Tel. +39 035 4282422;
email: service@LovatoElectric.com).
 Add the digit of the selected colour: 3 (green);
4 (red); 5 (yellow).
It is advisable to use the same colour of bulb as of
the actuator to obtain adequate light emission.
Not suitable for resistance-diode lamp-holders.
 Neon bulbs emit an amber light and may not be
suitable for use with green or blue pilot lights and
illuminated actuators.
 Glass with diffuser lens.
 Plastic neon bulb.

Dimensions
page D-33

REV. 02_11
electric
Control and signalling units 6-23
Accessories and spare parts for
buttons and selectors

Accessories and Order code Description Qty Wt


spare parts per
pkg CLICK
LM2T AU100
LM2T AU105
n [kg]
8 LM2T AT... Printed label to be 50 0.001
inserted in pilot lights
and push-buttons LM2T AU170
8 LM2T AT... 8 LM2T AU100 Legend holder 50 0.001
8 LM2T AU105 Legend holder (for 50 0.003
LM2T AU120
8 LM2T AU106 paper or
LP2T AU120
8 LM2T AU108 plastic
labels) LM2T A140

8 LM2T AU106 Blank paper label for 50 0.002


writing
(for LM2T AU105)
8 LM2T AU107 Transparent protection 50 0.001
for LM2T AU106 label
8 LM2T AU100 8 LM2T AU105 8 LM2T AU108 Blank plastic label for 50 0.002
engraving
(for LM2T AU105)
6
8 LM2T AU120 Mounting adapter 10 0.019
8 LM2T AU13 IP66 boot for 10 0.006
flush push-buttons
8 LM2T AU14 IP66 boot for extended 10 0.009
8 LM2T AU108 and illuminated
8 LM2T AU106 push-buttons
8 LM2T AU157 IP66 boot for double 10 0.007
push-buttons
(transparent)
8 LM2T AU167 Transparent protective 10 0.012
boot for L...2T B634...
button
8 LM2T AU170
8 LM2T AU170 Actuator gasket 10 0.006
 Available only on specific request contact our Customer Service
(Tel. +39 035 4282422; email: service@LovatoElectric.com).
 To preserve actuators degree of protection (IP65), place their gasket
between legend holder and mounting surface.
 For flush and extended push-buttons, add the digit of the required colour:
2 (black); 3 (green); 4 (red); 5 (yellow); 6 (blue); 7 (transparent); 8 (white).

Accessories and Order code Description Qty Wt


spare parts for per
pkg
LP2T (plastic) n [kg]
series only 8 LP2T AU120 Mounting adapter 10 0.012
8 LM2T A200 Socket spanner/wrench 1 0.003
for monoblock pilot lights

Dimensions
page D-33

REV. 02_11
6-24 Control and signalling units electric
Signal towers and beacons

Signal towers Order code Description Qty per Wt General characteristics


70mm pkg Signal towers are fundamental elements in
n [kg] manufacturing processes for the visual and audible
signalling of the system status.
Steady light modules BA15d fitting, direct supply. The signal towers can be assembled by stacking up to 7
Bulb (8 LT7 ALB... and 8 LT7 ALL...) not included. modules, in the following sequence, starting from the
8 LT7 EL1 Orange 1 0.082 top: red, yellow, orange, blue, green and white.
8 LT7 EL3 Green 1 0.082 The sound module, if any, must always be positioned at
the top of the signal tower.
8 LT7 EL4 Red 1 0.082
8 LT7 EL5 Yellow 1 0.082 Technical characteristics
8 LT7 EL6 Blue 1 0.082 Maximum operational voltage: 240VAC
Consumption of flash and sound modules:
8 LT7 EL8 White 1 0.082 LT7 FL B... in AC: 135mA
Blinking light modules. BA15d fitting. LT7 FL B... in DC: 75mA
Bulb (8 LT7 ALB... and 8 LT7ALL...) not included. LT7 FL E...: 20mA
8 LT7 GL B1 Orange, 24VAC/DC 1 0.083 LT7 FL M...: 15mA
LT7 S0 B: 25mA
8 LT7 GL B3 Green, 24VAC/DC 1 0.083 LT7 S1 B: 40mA
8 LT7 GL B4 Red, 24VAC/DC 1 0.083 LT7 S2 B: 200mA
LT7 S2 E: 40mA
6 8 LT7 GL B5 Yellow, 24VAC/DC 1 0.083
LT7 S2 M: 30mA
8 LT7 GL B6 Blue, 24VAC/DC 1 0.083 Material: Polycarbonate or anodised aluminium
8 LT7 GL B8 White, 24VAC/DC 1 0.083 Connections: Screw clamp terminals, maximum
8 LT7 GL E1 Orange, 110-120VAC 1 0.083 1.5mm2 conductor section
Operating temperature: -20...+50C; for 12VAC max up
8 LT7 GL E3 Green, 110-120VAC 1 0.083 to +40C
8 LT7 GL E4 Red, 110-120VAC 1 0.083 Number of stackable elements: Seven.
8 LT7 GL E5 Yellow,110-120VAC 1 0.083 Degree of protection: IP65; IP54 for 8 LT7 S0B sound
module.
8 LT7 GL E6 Blue, 110-120VAC 1 0.083
8 LT7 GL E8 White, 110-120VAC 1 0.083 Certifications and compliance
8 LT7 GL M1 Orange, 230-240VAC 1 0.083 Certifications obtained: cULus, GOST.
Compliant with standards: IEC/EN 60947-5-1,
8 LT7 GL M3 Green, 230-240VAC 1 0.083 IEC/EN 60947-1, UL508, CSA C22.2 n 14.
8 LT7 GL M4 Red, 230-240VAC 1 0.083
8 LT7 GL M5 Yellow, 230-240VAC 1 0.083 Combinations
8 LT7 GL M6 Blue, 230-240VAC 1 0.083
8 LT7 GL M8 White, 230-240VAC 1 0.083 Sound module Cover
Flash modules. With 4-Joule xenon bulb. (always on top) (supplied with
LT7 S LT7 CM 01 and
M

8 LT7 FL B1 Orange, 24VAC/DC 1 0.092 LT7 CP 01 module)


U

8 LT7 FL B3 Green, 24VAC/DC 1 0.092


M

8 LT7 FL B4 Red, 24VAC/DC 1 0.092


I

8 LT7 FL B5 Yellow, 24VAC/DC 1 0.092


X

8 LT7 FL B6 Blue, 24VAC/DC 1 0.092


A

8 LT7 FL B8 White, 24VAC/DC 1 0.092


M

8 LT7 FL E1 Orange, 110-120VAC 1 0.092


S

8 LT7 FL E3 Green, 110-120VAC 1 0.092 LT7 ALB


(incandescent
T

8 LT7 FL E4 Red, 110-120VAC 1 0.092 LT7 EL


bulb)
LT7 GL
N

LT7 EL 8 LT7 FL E5 Yellow, 110-120VAC 1 0.092 LT7 FL LT7 ALL


E

LT7 GL (LED bulb)


8 LT7 FL E6 Blue, 110-120VAC 1 0.092
M

LT7 FL
8 LT7 FL E8 White, 110-120VAC 1 0.092
E

8 LT7 FL M1 Orange, 230-240VAC 1 0.092


L
E

8 LT7 FL M3 Green, 230-240VAC 1 0.092


8 LT7 FL M4 Red, 230-240VAC 1 0.092
7

8 LT7 FL M5 Yellow, 230-240VAC 1 0.092


8 LT7 FL M6 Blue, 230-240VAC 1 0.092
Connection module
8 LT7 FL M8 White, 230-240VAC 1 0.092 LT7 CM 01 (metal)
LT7 S LT7 CP 01 (plastic)
Pulsed or continuous sound modules complete with cover.
8 LT7 S0 B 24VAC/DC, pulsed (90dB). 1 0.240
LT7 BP 01 LT7 TM
IP54 protection (plastic) (metal)
8 LT7 S1 B 24VAC/DC, 16 sound tones 1 0.240 LT7 BM 02
LT7 BM 01 (metal)
(80dB max). IP65 protection (metal) LT7 BP 02
8 LT7 S2 B 24VAC/DC pulsed (78dB) 1 0.240 (plastic)
or continuous Fixing base and extension tubes
8 LT7 S2 E 110-120VAC 1 0.240
(75dB)sound
8 LT7 S2 M 230-240VAC IP65 protection 1 0.240
Connection modules complete with cover.
8 LT7 CP 01 For plastic tubes, black 1 0.110
LT7 CM 01 colour, bottom entry
LT7 CP 01
8 LT7 CM 01 For metal tubes, black colour, 1 0.120
 84.5dB for 8 LT7 S2 B. bottom entry
 82.6dB for 8 LT7 S2 B.

Accessories and spare parts Dimensions


page 6-26 page D-34

REV. 02_11
electric
Control and signalling units 6-25
Signal towers and beacons

Signal beacons Order code Description Qty per Wt General characteristics


62mm pkg Signal beacons are fundamental elements in
n [kg] manufacturing processes for the visual and audible
signalling of the system status.
Steady light modules.
BA15d fitting, direct supply. Bulb not included. Technical characteristics
8 LB6 EL1 Orange 1 0.060 Maximum operational voltage: 240VAC
8 LB6 EL3 Green 1 0.060 Consumption of sound modules:
LB6 S2...: 150mA
8 LB6 EL4 Red 1 0.060 Material: Polycarbonate
8 LB6 EL5 Yellow 1 0.060 Connections: Screw clamp terminals, maximum
8 LB6 EL6 Blu2 1 0.060 1.5mm2 conductor section
Operating temperature: -20...+50C
8 LB6 EL8 White 1 0.060 Degree of protection: IP54; IP30 if used with
Blinking or steady light modules. 8 LB6 BP 04, 8 LB6 BP 06 or 8 LB6 BP 08.
BA15d fitting. Bulb not included.
8 LB6 GL B1 Orange, 12-48VAC/DC 1 0.060 Reference standards
Compliant with standards: IEC/EN 60947-5-1,
8 LB6 GL B3 Green, 12-48VAC/DC 1 0.060 IEC/EN 60947-1.
8 LB6 GL B4 Red, 12-48VAC/DC 1 0.060
Combinations
8 LB6 GL B5 Yellow, 12-48VAC/DC 1 0.060 6
8 LB6 GL B6 Blue, 12-48VAC/DC 1 0.060
L ig h t a n d s o u n d mo d u le s
8 LB6 GL B8 White, 12-48VAC/DC 1 0.060 LB6 EL - LB6 GL - LB6 S2B
8 LB6 GL M1 Orange, 24-230VAC 1 0.060 1 3 4 5 6 8
8 LB6 GL M3 Green, 24-230VAC 1 0.060
8 LB6 GL M4 Red, 24-230VAC 1 0.060
8 LB6 GL M5 Yellow, 24-230VAC 1 0.060
8 LB6 GL M6 Blue, 24-230VAC 1 0.060 Fixing base and extension tubes
8 LB6 GL M8 White, 24-230VAC 1 0.060
Sound-light pulsed or continuous modules. Bulb included.
8 LB6 S2 B1 Orange, 24VAC/DC (80dB) 1 0.060 LB6 BP 03 LB6 BP 05 LB6 BP 07

8 LB6 S2 B3 Green, 24VAC/DC (80dB) 1 0.060


8 LB6 S2 B4 Red, 24VAC/DC (80dB) 1 0.060
LB6 BP 04 LB6 BP 06 LB6 BP 08
8 LB6 S2 B5 Yellow, 24VAC/DC (80dB) 1 0.060
8 LB6 S2 B6 Blue, 24VAC/DC (80dB) 1 0.060
8 LB6 S2 B8 White, 24VAC/DC (80dB) 1 0.060
LT7 ALB
(incandescent bulb) LT7 TP0100

LT7 ALL LT7 BP 01 LT7 BP 02


(Led Bulb) (plastic) (plastic)

Only for light and sound modules.

LB6 EL
LB6 GL
LB6 S2...

Visual code Red Yellow Orange Blue Green White Interpretation of light and sound signals for signal
Meaning Danger. Warning and Mandatory Normal No specific towers and beacons
Emergency. Caution. command. situation. meaning. Light and sound signals are a fundamental element for
Abnormal Regular the safety of a system.
situation. operation. To avoid incorrect interpretations, an European standard
Sound Fast modulated Continuous Alternating Constant and Other sounds. has been introduced defining an equivocal meaning to
repetition or short sound. sound at. prolonged visual or audible
high-pitch constant tone sound signalling devices.
pulsing. after an alarm. Each colour or sound alarm corresponds to a specific
state of
Correlated Immediate Control Intervention No specific . Depending on operation of the connected system and various levels of
actions intervention intervention needed for action. the situation. warning, as given in the following table, according to
to deal with required. mandatory EN 981/EN 60073 standards.
dangerous action. The white coloured module does not have a specific
situation. meaning so it can be used as one may need.

Accessories and spare parts Dimensions


page 6-26 and 27 page D-34

REV. 02_11
6-26 Control and signalling units electric
Signal towers and beacons

Accessories and Order code Description Qty per Wt General characteristics


spare parts for pkg The assembly operation of the signal towers is simple
n [kg] and fast and does not require the use of any tools.
signal towers and The fixing of each element on top of the other is
Fixing bases.
beacons obtained by the bayonet insert joint, with slight pressure
8 LT7 BP 01 Horizontal surface mount, 1 0.045 and simple rotating movement. There are specific white
plastic, black colour inscriptions to indicate the correct alignment.
with 100mm extension
8 LT7 BP 02 Vertical wall mount, 1 0.078
plastic, black colour
Extension tube for plastic base, stackable sections.
8 LT7 TP 0100 100mm, black colour 1 0.029
Incandescent bulb, 5W, BA15d fitting.
8 LT7 ALB A 12VAC/DC 10 0.006
LT7 BP 01 8 LT7 ALB B 24VAC/DC 10 0.006
8 LT7 ALB E 130VAC/DC 10 0.006 1
1
8 LT7 ALB M 260VAC/DC 10 0.006 2
LED bulb, BA15d fitting.
6 8 LT7 ALL B3 Green, 24VAC/DC 10 0.010
2
8 LT7 ALL B4 Red, 24VAC/DC 10 0.010
8 LT7 ALL B5 Yellow/Orange, 24VAC/DC 10 0.010
LT7 BP 02 8 LT7 ALL B6 Blue, 24VAC/DC 10 0.010
8 LT7 ALL B8 White, 24VAC/DC 10 0.010
8 LT7 ALL E3 Green, 110-120VAC 10 0.010
8 LT7 ALL E4 Red, 110-120VAC 10 0.010
8 LT7 ALL E5 Yellow/Orange, 110-120VAC 10 0.010
8 LT7 ALL E6 Blue, 110-120VAC 10 0.010
LT7 ALB
8 LT7 ALL E8 White, 110-120VAC 10 0.010
Technical characteristics
8 LT7 ALL M3 Green, 230-240VAC 10 0.010 Consumption of bulb fitted on light modules:
8 LT7 ALL M4 Red, 230-240VAC 10 0.010 LT7 ALB A: 420mA
8 LT7 ALL M5 Yellow/Orange, 230-240VAC 10 0.010 LT7 ALB B: 210mA
LT7 ALB E: 43mA
8 LT7 ALL M6 Blue, 230-240VAC 10 0.010 LT7 ALB M: 22mA
8 LT7 ALL M8 White, 230-240VAC 10 0.010 LT7 ALL B...: <50mA
LT7 ALL  Used with yellow or orange light modules. LT7 ALL E...: <18mA
LT7 ALL M...: <17mA.

Accessories and Order code Description Qty per Wt Compliance


pkg Compliant with standards: IEC/EN 60947-5-1,
spare parts for IEC/EN 60947-1, UL508, CSA C22.2 n 14.
signal towers n [kg]
Fixing bases.
70mm only
8 LT7 BM 01 Horizontal surface mount, 1 0.099
metal, black finish
8 LT7 BM 02 Vertical wall mount, 1 0.184
metal
Extension tubes for metal base, anodised aluminium,
LT7 BM 01 fixed non-stackable sections.
8 LT7 TM 0100 100mm 1 0.016
8 LT7 TM 0150 200mm 1 0.024
8 LT7 TM 0300 300mm 1 0.048
8 LT7 TM 0400 400mm 1 0.064
8 LT7 TM 0500 500mm 1 0.080
8 LT7 TM 1000 1000mm 1 0.160

LT7 BM 02

LT7 TM

Dimensions
page D-34 and 35

REV. 02_11
electric
Control and signalling units 6-27
Signal towers and beacons

Accessories and Order code Description Qty per Wt General characteristics


spare parts for pkg The assembly operation of the signal beacons is simple
n [kg] and fast and does not require the use of any tools.
signal beacons There are specific white inscriptions to indicate the
Fixing bases for light modules.
62mm correct alignment.
8 LB6 BP 03 Horizontal surface mount, 1 0.040
plastic, black colour
8 LB6 BP 05 For 22mm hole type, 1 0.040
plastic, black colour
8 LB6 BP 07 For extension 1 0.020
connection, plastic,
LB6 BP03
black colour. Use with
fixing bases 8 LT7 BP 01
and 8 LT7 BP 02 2
1
Fixing bases for sound modules.
8 LB6 BP 04 Horizontal surface mount, 1 0.040
plastic, black colour
8 LB6 BP 06 For 22mm hole type, 1 0.040
LB6 BP05 plastic, black colour
8 LB6 BP 08 For extension 1 0.020 6
connection, plastic,
black colour. Use with
fixing bases 8 LT7 BP 01
and 8 LT7 BP 02

LB6 BP07

LB6 BP04

LB6 BP06

LB6 BP08

Dimensions
pages D-34 and 35

REV. 02_11
D-32 Dimensions [mm] electric
Control and signalling units

Flush push button with auxiliary contacts or lamp-holder Flush push button with Faston auxiliary contacts Drilling - Minimum recommended distances
(direct or resistor-diode type) 50
D 22.7 43
30

22.7 43 20.3 13.8


1 - 6 max 20.3 13.8 1 - 6 max

22.5

42.4
10
10

29.8
29.8

42.4
42.4

30

66
30

n1 LM2T AU120 n1 LM2T AU120


ADD-ON
n1 LP2T AU120 n1 LP2T AU120
ELEMENTS ADD-ON
n1 LM2T C... ELEMENTS n1 LM2T CF...
n1 LM2T VL230
n1 LM2T DL400...

 When Faston auxiliary contacts are used, the


vertical pitch must be 90mm minimum.

Push buttons Mushroom-head buttons 29.2


13.8 20.9 20.5 28.5
29
29.8

60
29.8

29.8

40

40
Flush Extended Shrouded Spring return Spring return Push-pull
L...2T B1... L...2T B2... L...2T B30... L...2T B614... L...2T B616... L...2T B624...
Push-push Push-push Illuminated flush Illuminated spring return
L...2T Q1... L...2T Q2... L...2T BL1... L...2T BL614...
Illuminated extended Illuminated push-push
L...2T BL2... L...2T QL1...
Illuminated push-push
L...2T QL2...

Reset button (complete unit)


140 max 13.8
19.1
35.5 32.6 33.8 24.2 49

29.8
42.4
40
40

40

40

20
Illuminated push-pull Turn to release Turn key to release Turn to release L...2T R1...
L...2T BL624... L...2T B634... L...2T B654... ISO13850 (ex EN418)
compliant
L...2T B6644

Potentiometer drive Selectors


56.8
35 27.5 27.5 27.5 27.5 23.9
29.8

29.8

29.8

29.8
39.4

LM2T P100 Knob Illuminated knob Lever Key


LM2T P110 L...2T S1... L...2T SL1... L...2T S2... L...2T S3...

Double-touch push buttons Double-touch push buttons Triple-touch button with LED integrated lamp-holder Transformer or flashing
with or without indicator with or without indicator middle extended button steady or flashing light lamp holder
2 flush buttons 1 flush and 1 extended buttons 1 - 6 max 51.3
10

1 - 6 max
16 17.4
28.5 12 28.5 12 28.5 12
25.2
30
54

54
54

STOP
57
43
20.3 20.3

L...2T B71... L...2T B72... - L...2T B73...


42.4
42.4
20.5

L...2T BL71... L...2T BL72...

LM2T EL... - LM2T ZL... LM2T YL... - LM2T GL...


LM2T DL... - LM2T VL... LM2T XL... - LM2T FL...
LM2T L... - LM2T M...

Pilot light head LED-integrated monoblock Monoblock pilot light Monoblock pilot light Monoblock pilot light complete
pilot light steady light complete with diffuser, complete with diffuser and with diffuser, 1-6.35 or 2-2.8
without terminal terminal protection Faston terminals without terminal
protection protection
38.4 14.3 42 16.5 43.3 16.5 42 16.5
16.5 1-6 max 1-6 max 1-6 max 1-6 max
29.8
29.8
29.8
29.8
29.8

LM2T IL1... LP2T ILA... - LP2T ILB... LP2T IL21... LP2T IL22... LP2T IL23...
LP2T ILE... - LP2T ILM...

REV. 02_11
electric
Dimensions [mm] D-33
Control and signalling units

Monoblock buzzers Transparent boot Button protection boot Double/triple button Threaded plug for
boot unused holes
D
36 16 30 20.4
35 18.1 25 21.3

33.4

33.4

29
28.9

44

55
1-6 max
LP2T ZG... LM2T AU167 LM2T AU13... LM2T AU14... LM2T AU157 LM2T A130

Knob selector Label holder Label Label holder Label Plastic disk for
protection mushroom-head push-buttons
30 29.8 27.5 22.5
27.5 27.8 27.8 ERGENCY
EM
36

12.2
45.6

A
48
15.4

12.4
A = 60mm
STOP
A = 90mm
LM2T AU185 LM2T AU105 LM2T AU10... LM2T AU100 LM2T A... LM2T AU11...

Joystick with free actuation lever Joystick with mechanical latch lever
22.7 43 22.7 43
1.5 1.5
1 - 6 max 70.5 1 - 6 max 70.5
10

10
42.4

42.4
29.5

29.5
30

30

Only for 20.1 Only for 20.1


LM2T J40 LM2T J20 LM2T J41 LM2T J21

LM2T J20... - LM2T J40... LM2T J21... - LM2T J41...

Control station with one actuator Control station for two actuators
72 56 65
72 56 65
4.2
4.2

4.2
4.2
66.5
49

85

34.5

98.5

117
81

54
22.3

6.4 54
22.3
L2PP 1A5 - L2PP 1A8
6.4

L2PP 2A8 (2x2mm index)


For 3, 4 or 5 actuator versions, increase the total length by the
pitch between the drillings, 35mm for each extra actuator.

Complete push button station with one actuator


72 56 65 29.9 72 56 65 33.5
4.2
4.2

4.2
66.5

66.5
49

85

49

85

54 54

6.4 6.4

L2PP 100 - L2PP 150 L2PP 110 - L2PP 115 - L2PP 160 - L2PP 165

72 56 65 34.7 24.2 72 56 65 49
4.2
4.2

66.5
66.5

49

85
49

85

54 54

6.4 6.4

L2PP 120 - L2PP 170 L2PP 130 - L2PP 180

REV. 02_11
D-34 Dimensions [mm] electric
Control and signalling units

SIGNAL TOWERS 70mm


Light modules Sound modules Connection modules
D LT7 EL... LT7 S0 B LT7 S1... LT7 CM 01
LT7 GL... LT7 S2... LT7 CP 01
LT7 EL... LT7 FL...

16
LT7 GL...
LT7 FL...
LT7 S1... 60

13
LT7 S0 B LT7 S2...

13
60

92

72
56

45.5
70 70 70 70
473.5

453.9
381.5
325.5
269.5
213.5
157.5
101.5

5
7 LT7 CM 01 - LT7 CP 01
42

48

SIGNAL BEACONS 62mm


LB6 EL... LB6... LB6... LB6...
LB6 GL... with base LB6 BP 03 with base LB6 BP 05 with base LB6 BP 07
LB6 S2... and LB6 BP 04  and LB6 BP 06  and LB6 BP 08 
62.5
62.5

62.5

62.5
17
31

37
23.5

22
85
62 62 62

5
65

32.5

18.8 37.5

 With slits for sound light modules LB6 S2...

REV. 02_11
electric
Dimensions [mm] D-35
Control and signalling units

ACCESSORIES - Extensions and bases


LT7 BP 01 LT7 BP 02 LT7 BM 01 LT7 BM 02 D

11
25 25 20 71
30

18
22

20 20 105

20

9
51

8
70
5 5

109
64.5
5
122

54

54
21
54
38 54
70
14.5

67
8

70
54

54

LT7 TP 0100 LT7 TM...


25 20
20
22

1000
122

REV. 02_11
electric
Wiring diagrams W-11
Control and signalling units

FOR PUSH BUTTONS AND SELECTORS


LM2T C10 LM2T C10A LM2T C01 LM2T C01D LM2T EL400 LM2T ZL230 LM2T YL... LM2T GL... LM2T T100 LM2T L...
LM2T DL400 LM2T VL230 LM2T XL... LM2T FL... LM2T M... W
7 1 5 X1 X1 X1 X1 X1 X1
3

LED

8 2 6 X2 X2 X2 X2 X5 X2
4
TEST

BUZZERS 22mm SIGNAL TOWERS 70mm SIGNAL BEACONS 62mm


L...T ZG... LT7... LB6...

X1 LT7 CM 01 - LT7 CP 01 Connect terminals C and 1 as indicated X1


to power the first module. If other
BULB modules are fitted, the respective
BULB
terminals must be connected.

C 1 2 3 4 5 6 7
X2 X2

L
N

Limit, micro and foot switches

LIMIT SWITCHES, KB - KM - KC - KN TYPE


K...S11 K...L11 K...L02 K...S02 K...L20 K...A11 K...L03 K...L12 K...L21
K...D02
Snap action Slow break Slow break Snap action Slow break Slow break Slow break Slow break Slow break
21 13 21 13 11 21 11 21 13 23 17 25 11 21 31 13 21 31 13 23 31

22 14 22 14 12 22 12 22 14 24 18 26 12 22 32 14 22 32 14 24 32
1NO + 1NC 1NO + 1NC 2NC 2NC 2NO 1NO + 1NC 3NC 1NO + 2NC 2NO + 1NC
make before break
LIMIT SWITCHES, KP TYPE LIMIT SWITCH, T TYPE LIMIT SWITCHES, PL TYPE
KP...S11 KP...L11 TS... TL... PLN A1... PLN A2... PLN C1... PLN C2.... PLN U1...
Snap action Slow break Snap action Slow break PLN 978
21 13 21 13 13 21 21 13 11 11 21 13 13 23 21 13
yellow/green

yellow/green
black

black
brown

brown
black

black
blue

blue

14 22 22 14 12 12 22 14 14 24 22 14
22 14 22 14
1NO + 1NC 1NO + 1NC 1NC 2NC 1NO 2NO 1NO + 1NC
1NO + 1NC 1NO + 1NC

LIMIT SWITCHES FOR NORMAL STOPPING


RS1... RS2... RS3... PLN U1AT... PLN U1... P2L10...
TS1... TL1... P2L8...
Snap action Slow break Slow break
13 21 13 21 13 23 21 13 21 13 13 23 31 41

14 22 14 22 14 24 22 14 22 14 14 24 32 42

1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 1NO + 1NC 2NO + 2NC

LIMIT SWITCHES FOR EMERGENCY STOPPING MICRO SWITCHES, KS TYPE


RS13... PLN13... P2L13... P2L15... KS...
TL13...

NC NO
2 3
13 14 11 12 31 32 13 23 31 41

1
21 22 21 22 41 42 14 24 32 42
COM

REV. 02_11