You are on page 1of 2

Casa C3200 CMTS Quick Installation

Install rack mounting hardware comprising Locate and install the rack mounting
1
Open the shipping container.
2 mounting ears, screws, and spacers. 3 brackets.
Whats inside the box?
Remove the system and the box containing
C3200 chassis Position each bracket inside rack.
the system accessories.
Console cables and related Turn clockwise to tighten screws.
hardware, SFPs, CD-ROM
Spacer
Screw
CAS
A
C3000SYSTEM
S

Installation references
CCASA
AS SYS
A 3 4
5
ALM
0 1
2

CASA
SYS
C3000 TEMS
CCASA
AS SYS
A 3 4
5
ALM
0 1
2

C3200 CMTS Hardware G3


G4

Installation Guide
Casa Systems -- CMTS
Release Notes
Corresponding
Corresponding
A
CAS EMS bracket at
brackets
Observe all electrical warnings and SYS
T level position
on left side.
precautions during installation.

To populate rack, start from the first available postion from Connect chassis to ground. Install SFPs and connect Ethernet RJ-45
4 the bottom of the rack. 5 Remove the vented protective covers.
6 (copper) or LC (fiber optic) connectors into SFPs.

Install four screws (two per mounting ear) and turn clockwise
Remove GND screw and position
to tighten.
GND cable terminal connectors
over threaded mounting holes.

Positon ring terminals and replace screws, IOIO

G11
G4

610
G0

G5

G6

G9
G8
G1

G2

G7

STATUS
G3
10/100MI

ALARM
CASA SYSTEMS SYS 3 4 5
then turn screwdriver clockwise to tighten
C3000 CCASA
ASA
ALM 0 1 2

Dual DC power modules

CASA SYSTEMS SYS 3 4 5

C3000 CCASA
ASA
ALM 0 1 2
GND
RTN -48V
RTN -48V

GigE interfaces to routers, switches,


RTN -48V
RTN -48V

terminals

G0

G1

G2
10/100MI
CASA SYSTEMS SYS 3 4 5
and servers (DHCP, TFTP, ToD).
C3000
ESD strap
CCASA
ASA
ALM 0 1 2

For remote management over


Telnet/SSH, insert Ethernet RJ-45
connector into 10/100 Ethernet port.
Default IP address is 192.168.2.100;
CASA SYSTEMS
C3000 CCASA
ASA
SYS 3 4 5

ALM 0 1 2
Protective covers subnet mask is 255.255.255.0.
GND cables
Reinstall the vented covers. A hole is located at the bottom Insert Ethernet RJ-45 into
of the cover for routing the GND cables. 10/100 Fast Ethernet port

Connect chassis frame to GND. See the Casa Systems --


C3200 CMTS Hardware Installation Guide.
Casa C3200 CMTS Quick Installation (cont.)
Attach AC or DC power cabling. See the Hardware Installation Guide
Connect RF I/O cables up to upstream and
7 downstream ports. Tighten F-connectors 8 Connect PC or terminal to SMM for local setup. 9 for information on power sources and redundancy requirements.
to 15 inch-lbs of torque.
Apply system power when ready. Turn on local console to confirm
IOIO successful system bootup. The CASA-CMTS# prompt will display on

G11
G4

610
G0

G5

G6

G9
G8
G1

G2

G7

STATUS
G3
10/100MI

ALARM
DQM QAM console. Check LEDs for operational status.
downstream 10/100 G1 G2 G3 G4

RF output Dual DC power supplies On AC systems

CASA SYSTEMS SYS 3 4 5

C3000 CCASA
ASA
ALM 0 1 2
RJ-45 to DB-9

RTN -48V
RTN -48V
adapter GND
terminals
DCU
upstream
RJ-45 to RJ-45
RF input
cable

Console settings:
Protective covers
AC power plugs/
115200 bps ON/OFF switches
8 data bits Terminal or PC
No parity with DB-9

RTN -48V
RTN -48V
1 stop bit serial port.
No flow control
GND cables

From the local console or from a remote session such as a PuTTY session over Telnet or -48V cables
10 SSH to the default IP address 192.168.2.100 of the 10/100 Ethernet port (eth 0), perform the RTN cables
following tasks:

1. Login to the CLI using the root login and the casa password. Configure the CMTS software, interfaces, routing protocols, BPI,
2. Enable the CMTS privileged mode to configure the CMTS. 11 load balancing, spectrum management, modulation profiles, etc.
running configuration. The default password is casa.
3. Display the CMTS software version. Refer to the following documents, available as downloads
4. Enable configuration mode. in PDF format from the Casa FTP site.
5. Change the default IP address of the CMTS management port. See the example IP address below.
Casa Systems -- CMTS Release Notes
.
CASA-CMTS login> root Casa Systems -- C3200 CMTS Hardware Installation Guide
Password: casa Casa Systems -- CMTS Software Configuration Guide
CASA-CMTS> enable Casa Systems -- CMTS Debugging and Diagnostics Reference
Password: casa
CASA-CMTS# show version
Running Image: SMM Rel 5.4, Ver 21, build 12, Tue Mar 29 09:21:33 EST 2011,(mlin)
Configured boot device: net
Target IP: 192.168.2.100, Host IP: 192.168.2.100
Boot Image: casa_6000.gz.rel5.4.21.build12

CASA-CMTS# config
CASA-CMTS(config)# interface eth 6/0
CASA-CMTS(config-if-eth 6/0)# ip address 135.2.0.0 255.255.255.0