SAURASHTRA CEMENT LIMITED,


RANAVAV
ANNEXUIRE 'C'
LIST OF AUXILLARY EQUIPMENTS OF MWM DG SET
Equip. No. Description Specification Suppy
No.
[A3] HFO Separator unit Impoted
A3.1 Gear pump Cap.-1.6 m3/hr.
Pr.-3/5 bar, 950 rpm
Motor- 0.75 kw
A3.2 Strainer 400 micron
A3.3 3-way valve -
A3.4 Electric heater for hfo 25 kw
A3.5 Separator - Purifier Cap-1500 lit/hr.
Make-Westfalia, germany
A3.5 Separator - Clarifier Cap-1500 lit/hr.
Make-Westfalia, germany
A3.6 Electric contro cabinet IP 54

[A4] Booster module Impoted


A4.1 Automatic 3/2-way valve with limit switch -
A4.2 Flow meter max.50 LPM
A4.3 Mixing tank Cap.-150 litres
A4.4 Gear pump Cap-4.8 m3/hr.
Pr-8/10 bar
A4.5 Fuel heater 50kw
A4.6 Viscometer Range up to 50 cst
A4.7 Electric contro cabinet IP 54

[B] Lube oil system Impoted


B1.1 Gear pump Type- self priming
B1.1 Lube oil tank integrated with engine base frame Cap-7000 ltrs.

B1.2 Lube oil filters engine mounted. Self cleaning type


while engine is running
B1.3 Lube oil thermostate DN-150

[B2] Lube oil separator Impoted


B2.1 Gear pump Cap.-2.2 m3/hr.
Pr.-3/5 bar, 950 rpm
Motor- 1.5 kw
B2.2 Lube oil heater 30kw
B2.3 Lube oil separator Cap.-2.2 m3/hr.
Pr.-9 bar, 950 rpm
MOTOR-11KW
Page 2 of 2

Equip. No. Description Specification Suppy


No.
[B3] Lube oil cooling/ Filteration system Impoted
B3.1 Safety valve 132 cum per hr.
9.0 bar
DN-100
B3.2 Plate heat exchange 783 kw
66/54 deg.C
Range 43/54 deg.C
B3.3 Automatic back flushing filter 132 cum per hr.
34 micron
V-15 Litres/min

[C] Cooling water system


[C1] Engine jacket water system Impoted
C1.1 Jacket water thermostate DN-150
C1.2 Jacket water heat exchanger Alfa laval make
C1.3 Jacket water expanson tank 250 litres cap.

[C2] Engine charge air cooling water Impoted


system
C2.2 Charge air cooling water thermostate DN-125
C2.2 Charge air cooling water heat exchanger Alfa laval make
C2.3 Charge air cooling water expanson tank 250 litres cap.
C2.4 Charge air coolers Engine mounted -
C2.5 Engine water maintenance tank Cap-5000 ltrs.
C2.6 Water piping inside dg room -
C2.7 Water piping outside dg room -
C2.8 Water circulating pumps for c/a ; 02 nos 100 ltr/hr/, kirloskar make Indegineous
Water circulating pumps for 207 ltr/hr/, Kirloskar make Indegineous
jacket water : 02 nos

[C3] Open circuit : Cooling Tower Indegineous


C3.1 Cooling Tower Paharpur supply
Model 457 201
Gear reduce Ratio 4.56 : 1
C3.2 Raw water pumps ; 02 nos Kirloskar make
Capacity 312 cubic mtr/hour flow, 30 Mtr
head
Model UP 150/38 B