Professional Documents
Culture Documents
Mechanical specifications
1)
Remarks Weight approx. Units per 3) 9 | 0.4
Type No. Description
mm | inches kg | lb antenna
1319 | 51.9
1384 | 54.5
1529 | 60.2
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
Wall mounting: No additional mounting kit needed.
Grounding: The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.
Correlation Table
Frequency range Array Connector
Adjustment
1710 2200 MHz B1 12 mechanism
with integrated
1710 2200 MHz B2 34 scale
All dimensions in
mm | inches
B1 B2
Left Right
Layout of interface:
255 | 10.0
49 | 1.9
71 | 2.8 *
41 | 1.6
102 | 4.0 *
Subject to alteration.
315 | 12.4 *
936.4881/b
Bottom view
* Dimensions refer to radome
All dimensions in mm | inches
Page 2 of 2 742236V01 Any previous data sheet issues have now become invalid.
www.kathrein.com
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820
Mounting Hardware
Clamp Included in the Scope of Supply
152 [5.98]
100 [3.94]
[0.790.98]
40 [1.57]
72 [2.83]
2025
40 [1.57]
15
21
4 4.53]
5
[1.6
M10 MA = 25 Nm
M8 MA = 20 Nm
35 [1.38]
64 [2.52]
125 [4.92]
2025
[0.790.98]
Subject to alteration.
936.3920/c
Please note: Kathrein does not recommend to use counter nuts. All dimensions in mm and [inches]
The additional nuts supplied are only meant as spares.
Any previous data sheet issues have now become invalid. 738546 Page 1 of 1
www.kathrein.de
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820
General Instructions
for Adjustment Mechanism
1
2
2
Adjustment wheel with twist-lock Thread for fixing the protective To set the downtilt angle exactly,
function. cap or the RCU (Remote Control you must look horizontally at the
Downtilt spindle with integrated Unit). scale. The lower edge of the gear-
scale. Gearwheel for RCU power drive. wheel must be used for alignment.
0 max.
max. 0
Remove the protective cap. Set downtilt angle by rotating the Screw on the protective cap again.
adjustment wheel.
For a description of RCU installation please refer to the respective data sheet.
Internet: www.kathrein.de Page 1 of 2
KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973
General Instructions for Feederline Installation
on Panels with four Connectors
arranged on two Levels
Please note: In order not to damage the interfaces, please make sure that only the right tools are used.
Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench
width.
4 3
2 1
There are four interfaces for feeding the antenna The connectors are mounted at two levels in order to facilitate feederline
located at the bottom. installation.
Start with the rearside located inter- After feederline installation the optional For a full description of RCU installation
face no. 1. remote control units (RCU) can be please refer to the respective data sheet.
mounted if required.
Place the connector carefully and fix the
nut using a torque-wrench (according to
the manufacturers guidelines).
Subject to alteration.
Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required,
nor is it recommended by the connector manufacturers.
Environmental Kathrein cellular antennas are designed to operate under the environmental conditions
conditions: as described in ETS300019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
Low temperature: 55 C
High temperature (dry): +60 C
For antennas equipped with FlexRET: The electrical downtilt adjusting is designed to
operate under the environmental conditions as described in the valid data sheet of the
FlexRET.
Ice protection: Due to the very sturdy antenna construction and the protection of
the radiating system by the radome, the antenna remains operational even under icy
conditions.
Environmental Kathrein antennas fulfil the stated specifications after completion of the environmental
tests: tests as defined in ETS300019-2-4. The homogenous d esign of Kathreins antenna
families uses identical modules and materials.
Extensive tests have been performed on typical samples and modules. The vibration
test has been adapted relating to frequency and acceleration to the conditions of mast
mounted antennas.
Please note: As a result of more stringent legal regulations and judgements regarding product
liability, we are obliged to point out certain risks that may arise when products are
used under extraordinary operating conditions.
The details given in our data sheets have to be f ollowed carefully when installing
the antennas and a ccessories.
Site planning and installation must be carried out by qualified and experienced
staff. All relevant national safety regulations must be upheld and respected.
Incorrect site planning, faulty installation, as well as interfering surroundings
on site, may lead to deviations in the electrical parameters compared to those
specified in the respective data sheets.
The connectors on this product are only suitable for connecting to the compatible
counterpart. Please ensure that the connected cable has been fitted with a
connector of the same standard, otherwise damage may occur.
The tilt values will be set to any arbitrary value in the given tilt range. These values
Subject to alteration.
are independent from the frequency band or antenna type and can vary between
antennas and bands.
EU-RED Hereby, Kathrein Werke KG declares that the radio equipment is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at
the following internet address: http://www.kathrein.com
936.4694/d
Our quality assurance system and our RoHS Our products are compliant to the
environmental management system apply EU Directive RoHS as well as to other
to the entire company and are certified environmentally relevant regulations
by TV according to EN ISO 9001 and (e.g. REACH).
ENISO 14001.
Any previous data sheet issues have now become invalid. Page 1 of 1
www.kathrein.com
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820