Professional Documents
Culture Documents
Collection
Gas Fireplaces
The Designer Line represents the
Black
Although Escape is the first gas fireplace in the world to remove all visible
firebox sheet metal, what makes it even more exceptional is what we've added: Graphite
Aged Brass
Black
Graphite
Arched elegance, robust heat and high efficiency—it’s a powerful combina-
tion. We took serious heat output and stylishly wrapped it in a classic, authentic
arched firebox–formed from our patented FireBrick material, providing a realistic
"brick-look" with warm, radiant heat. Available in 36" and 42" models.
New Bronze
Essence front
Cyclone Custom shown with custom bar application Cyclone System shown
with Brushed Copper
decorative front (also
available in Brushed
Nickel) and custom
Bisazza tile.
There’s an opportunity for a fireplace around every corner. Designed to slip into
corners and tight spots, this compact arched fireplace transforms any room where
Everest®
space is an issue, coziness a must.
Tall, bold
DF-CRES2-BK front
& handsome
24-5/8
24-5/8 [626] 15-5/8
[626] 24-5/8
34-7/8 15-5/8 [397]
Specifications Specifications 34-7/8
[885]
[626]
[885] 4-1/2
4-1/234-7/8 [113]
[397] 15-5/8
[397]
[113] [885] 4-1/2
[113]
37
24-1/2 37 [939.8]
13-1/2 24-1/2 [939.8]
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE Btu/Hour Input MODEL FRONT WIDTH BACK WIDTH 13-1/2
HEIGHT [342] DEPTH GLASS [622]
[622] SIZE Btu/Hour
24-1/2
37
Input[939.8]
[342] 13-1/2 [622]
[342]
Unit Framing Unit Framing Unit Framing Unit Framing Unit Framing Unit Framing Unit Framing Unit 5-3/16 Framing 5-3/16
Cerona-36 30-1/4 x 23-1/2 25,000-37,500 (NG) SPECIAL HEADER 11-1/4 [132]
Crescent II REQUIREMENTS. SEE 11-1/4 [283] [132]
8
27-3/4
5-3/16x 28-1/2 29,500 (NG)
41-1/8 42-1/8 28-1/2 42-1/8 49-7/8 50-1/2 21-3/4 22-1/4 34-1/2 35-1/2
INSTALL MANUAL 25-3/8
FOR 35-1/2 43-1/8 [283]43-5/8 19-1/4
8 11-1/4 19-3/4
[203] [132]
7-1/2 [203] [283] 8
[190] DETAILS
Cerona-42 48-1/8 49-1/8 35-3/8 49-1/8 54 54-1/2 21-3/4 22-1/4 35-7/8 x 27-3/4 32,000-48,000 (NG) [203]
Cerona-36 Top View Side View Front View Side View Top View
24-5/8 Side View Front View ELECTRICAL Side View
28-1/2 41-1/8 [1046] MINIMUM 6" VERTICAL [626] 15-5/8 ELECTRICAL ACCESS
RISE REQUIRED BEFORE 34-7/8 [397] ACCESS ELECTRICAL
[724] [885] ACCESS
14-1/4 90° ELBOW 4-1/2
[362] [113]
1-3/4
1-3/4 [43]
49-7/8 37 30-3/4 [43] 1-3/4
43 39-7/8 30-3/4
[1092] 23-1/2 [1268] 24-1/2
39-7/8 [1013] [939.8] [780] [43]
21-3/4 [595] 34-1/2 13-1/2 [1013]
[622] [780] 30-3/4
[877] 60-1/2 [342]
39-7/8
GAS LINE
12-1/2 [316] [551] GAS LINE[1013] [780]
[1537] ACCESS 1
ACCESS GAS LINE 1 [25]
GAS LINE ACCESS [25] 1
5-3/16
ACCESS 30-1/4 11-1/4 [132] 6
6 [25]
8 [204] 2-1/8 [54] 6-5/8 [169] [152]
[767] [283] 8 [152] 6
33-7/8 2-1/4 [56] [203] 6 2-7/8 23-1/4 15-1/8
15-1/8 [152]
7 [178] 6 2-7/8
[152] 23-1/4 [385]
[860] ELECTRICAL [152] [74]
[74]
6 [589]
[589] [385] 15-1/8
5-1/2 [130] ACCESS 2-7/8 23-1/4
[385]
[152] [74] [589]
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE Btu/Hour Input Side View Front View Side View Side View Bottom View
Unit Framing Unit Framing Unit Framing Unit Framing 5-1/4 5-1/4 28-1/4 28-1/4
Escape-36 36 x 30 31,000–40,000 (NG) [134] [134] 1/2 1/2 SLIP SECTION 2-3/4
50-7/8 51-1/2 50-7/8 51-1/2 35-1/2 46 21 22 [718] [718]
[12] [12] [71]
(2) (2) GAS LINE
Escape-42 56-7/8 57-1/2 48 57-1/2 41-3/8 52-1/2 21 22 42 x 36 35,000-52,000 (NG) ACCESS
FIRESTOP
32-3/4
Escape-ST 59-15/16 60-1/4 59-15/16 60-1/4 46-3/8 46-1/2 30 30 39-7/16 x 35-1/8 43,500 - 57,500 (NG) 49-1/2 49-1/2 [831] 2-1/4
GAS LINE
GAS LINE 47 47 41-1/8 2 [57]
ACCESSACCESS [1258] [1258]
[1195] [1195] [1069] 41-3/8 [51]
[1050]
Escape-36 Top View Side View Front View
1-1/4
5-3/4 5-3/4 2-1/2 2-1/2 30-1/8 30-1/8 17 ELECTRICAL [33]
[146] [146] [63] [63] [767] [767] [430] ACCESS
MODEL FRONT WIDTH BACK WIDTH HEIGHT 8-15/16 DEPTH 8 GLASS SIZE Btu/Hour Input
[227] 8-15/16
8-15/16 8 [227][203] 8
[203]
Unit Framing Unit Framing Unit[227] Framing Unit
[203] Framing
Everest 20-7/8 26-7/8 x 33-3/8 23,000-33,000 (NG)
Escape-42 Top View Side View Front View 34-1/16 35-1/16 17-7/8 35-1/16 50 50-1/2
[531] 20-7/8 20-7/8 21-3/8
20-7/8 [531]
[531]
Ø8
[203.1] Ø8
Ø8 [203.1]
Top View Side View Front
[203.1] View Side View
54-1/2
8-15/16 8 [1384] 54-1/2
[227] 54-1/2 [1384]
[203] [1384] 47-7/16 49-7/8
45-7/16 [1205] 47-7/16 [1266] 49-7/8
[1154] 47-7/16 45-7/16 36-1/8 49-7/8
[1205] ELECTRICAL
20-7/8 45-7/16 [918] 36-1/8 [1266]
[1205] [1154] [1266] ACCESS ELECTRICAL
[531] [1154] 2-18 36-1/8 [918] ELECTRICAL
4-11/16 ACCESS
[918] 2-18 2-5/16
2-18
[55] [118] ACCESS[59] 4-11/16 2-5/16
[55] 4-11/16 2-5/16 [118] [59]
Ø8 [55] [118] [59]
[203.1]
Escape-ST Top View 23-3/8
Side View Front View Side View GAS LINE [593] 23-3/8
5-12 23-3/8 [593] 4-11/16
59-15/16 [1522] 59-15/16 [1522] ACCESS GAS LINE
[593] 28-13/16 [119] 4-11/16
59-15/16 [1522] 59-15/16 [1522] GAS LINE [139]ACCESS 5-12
[732] 28-13/16
4-11/16
ACCESS 5-12 28-13/16 [139] [732] [119]
[139] [732] 34-1/8 [119]
12-3/4
12-3/4 12-3/4
12-3/4 54-1/2 [866] 34-1/8
[324] [324] 34-1/8 [866]
[324] [324] [1384] [866]
45-3/8 45-3/8
Ø8 [203]
Ø8 [203] Ø8 [203] 45-3/8
Ø8 [203] [1152] [1152] 45-3/8
46-3/8 46-3/8 47-7/16 49-7/8
[1152] [1152]
46-3/8 [1178] [1178] 46-3/8 45-7/16 [1205] [1266]
35-1/8 35-1/8
[1178] [1178] [1154] 36-1/8 ELECTRICAL
35-1/8 [892] [892] 35-1/8 [918] ACCESS
15
15 15 [892]
15
[892] 2-18 4-11/16 2-5/16
[381]
[381]
14
[381] 14
[381] 14
14 12 [305] 12 [305]
[55] Dimensions in diagrams are in inches and
[118]millimeters.
[59] Dimensions in table are in inches. Product information is not complete and is subject to change without notice. Product installation must
[356] [356] 12 [305] 12 [305]
[356] [356]
adhere strictly to instructions shipped with product. We recommend measuring individual units at installation. Assumes the use of 1/2" sheetrock. NOTE: Combustible material should not cover
30 [762] 30 [762] 9-1/8 9-1/8 the face. Make sure you do NOT cover the decorative door opening.
30 [762] 30 [762] 39-7/16 1[1002]
[25] 39-7/16 [1002]1 [25] 9-1/8 1 [25] 1 [25] 9-1/8
30-3/8 [784]
39-7/16 [1002]
30-3/8 [784] 42 [1066] 42 [1066]
39-7/16 [1002]
[232]
[232] [232]
[232] 23-3/8
GAS LINERefer to installation manual[593]
for detailed specifications on installing this product. Heat & Glo reserves the right to update units periodically. The flame and ember appearance may vary based on
30-3/8 [784] 42 [1066]
30-3/8 [784] 42 [1066]
58-1/8 [1476] 58-1/8 [1476]
the venting configuration used.4-11/16
58-1/8 [1476] 58-1/8 [1476]
ACCESSthe type5-12 28-13/16
of fuel burned and Actual
[119] product appearance, including flame, may differ from product images.
[139] [732]
34-1/8
[866]
IntelliFire™
Our exclusive, state-of-the-art IntelliFire ignition system reduces gas consumption and thermogenerator wear by providing a pilot flame
only when needed. It also supplies a back-up battery system to run the fireplace during a power outage.
FireBrick®
FireBrick technology provides the warmth and glow of a real wood burning fire. Our patented Firebrick technology uses heat and
compression to seamlessly mold ceramic fiber material into uniquely shaped fireboxes with authentic brick patterns. FireBrick technology
resists rust and corrosion on the interior of the firebox and eliminates noise associated with the heating and cooling of metal. FireBrick
technology also generates, retains, and radiates significantly more heat into the room than a metal fireplace. All Heat & Glo products
featuring FireBrick technology are AFUE rated, energy efficient, and offer an airtight seal, for peace of mind and comfort.
U.S. Efficiencies
Steady State
Since most homeowners use their fireplaces for an extended time while they are in the room, Steady State measures how efficiently your
fireplace converts fuel to heat once it is warmed up and running in a “steady state”.
AFUE
AFUE rating is more typically used with appliances, like your furnace, that continually cycle on and off to maintain a constant temperature.
77.5% (NG) 78.1% (NG) 56.8% (NG) 64.2% (NG) 69.3% (NG) 71.5% (NG)
Steady State
77.5% (LP) 78.1% (LP) 56.8% (LP) 64.2% (LP) 69.3% (LP) 71.5% (LP)
61.4% (NG) 60.7% (NG) 50.3% (NG) 52.8% (NG) 60.5% (NG) 43.6% (NG)
AFUE
64.8% (LP) 63.6% (LP) 54.6% (LP) 57.0% (LP) 63.9% (LP) 50.5% (LP)
Canada Efficiencies
EnerGuide (CSA P4.1.-02)
EnerGuide is a rating used in Canada to measure annual fireplace efficiency.
EnerGuide 64.1% (NG) 63.0% (NG) 54.5% (NG) 59.0% (NG) 62.5% (NG) 46.3% (NG)
(CSA P4.1.-02) 65.6% (LP) 64.1% (LP) 56.3% (LP) 60.7% (LP) 64.9% (LP) 49.4% (LP)
HNG-1017U-1109