B Fixing All units shall be properly fixed and installed n the indicated
positions with all necessary lugs, straps, brackets, etc. of the units
as shown on the drawings.
Fixing screws, nuts, bolts, rivets and other fastening devices shall
be aluminium, stainless steel or cadmium plated to the Architect's
approval. Where visible, they shall blend with the finish of the
Aluminium extrusions.
UTSB/KUMP/1 92
SPECIFICATION
Aluminium Work
B Glass And Glass and the glazing shall be locally manufactured M.S.G. Glazing
Glazing clear float glass or equivalent to be approved by the S.O. and in
accordance with B.S. 952 and free from bubbles, specks all other
defects.
D Structural All windows etc. shall be designed to withstand loads due to:-
Design
Wind pressure
Dead loads of infill panels etc.
Live loads that may be imposed.
A Erection All items under this heading shall be set in their correct locations
as shown in the drawings and shall be level plumb and square at
their proper elevation and in alignment with all work.
UTSB/KUMP/1 93
SPECIFICATION
Aluminium Work
All joints between metal and masonry shall be fully caulked and
pointed.
B Protection The aluminium frames are not to be allowed to rub or slide against
each other and significant surfaces should be well protected during
transportation. They must be wrapped with stout paper, cardboard
or other protective media which must not be allowed to get damp.
The Contractor shall ensure that all aluminium and glass shall be
thoroughly cleaned with plain water or water with soap or household
detergent on completion of the job. No abrasive agents shall be
used.
UTSB/KUMP/1 94
SPECIFICATION
Aluminium Work
to scale dimensions.
UTSB/KUMP/1 95