You are on page 1of 3

In Port Reduction, we are converting from 2 RF modules on 2G/U1900 4W Diversity to 1RF module with

no diversity.

1. Re-commission the U1900 to re-configure RF ports for 1 module

Delete ports from 2nd FXFB


Go back and un-check RF Sharing for 2nd module
Unplug the 2nd module fibers then re-commission the 2nd RF module out.

Login to the 2G and delete the 2nd RF module and change the diversity in the BSC to no diversity.

The system module will detect the FRIE but dont commission it in. The fibers will be moved at another
time when the new system module for the U2100 will be installed.

You might also like