RI-330 User Manual

1. Access control mode (default setting password is 123456)


(01 disable mode02 proximity card only03 proximity card then press
password04 proximity card or press password)
A. disable mode:
Press *123456 01#
B. proximity card only mode:
Press *123456 02#
C. proximity card then press password mode:
Press *123456 03#
D. proximity card or press password mode:
Press *123456 04#
2. Append a card (card number is 00456789)
(1) Press *123456 1 then proximity a card or press card number 00456789#
(2) Repeat step (1) append another card.
(3) Press * to finish.
3. Delete a card
(1) Press *123456 2 then proximity a card or press card number 00456789#
(2) Repeat step (1) delete another card.
(3) Press * to finish.

4. Append batch of card


(1) Press *123456 3 then proximity first card or press first card number 00456789#
(2) Press amount of cards 2~100 #
5. Delete batch of card
(1) Press *123456 4 then proximity first card or press first card number 00456789#
(2) Press amount of cards 2~9999 #
6. Delete all cards
(1) Press *123456 5
(2) Press password again 123456#
7. Door unlock time
A. Latch mode(relay ONOFF alternately )
Press *123456 60#
B. Momentary mode(1255 second)
(1) Press *123456 6
(2) Press 1255#
8. Alarm time
A. Disable alarm function.
Press *123456 70#
B. Set alarm time form 1 to 255 second.
(1) Press *123456 7
(2) Press 1255#

9. Change setting password (new setting password is 654321)


(1) *123456 8
(2) Press new setting password 654321#
10. Chang unlock password (new unlock password is 4321)
(1) *123456 9
(2) Press new unlock password 4321#
11. Set communication station number 1 to 32
(1) *123456 00
(2) Press 01 ~ 32#

How to control unlock relay? (unlock password is 1234)


To near the proximity card to reader or press *1234# on reader standby
mode.
Wiring diagram :
CN1 Power and signal input
Red Black Brown Orange Yellow Green Blue
1 2 3 4 5 6 7
+ -
Pin 1,2 Power
Pin 3,7 Door sensor(N.C.)
Pin 4,7 Unlock button(N.O.)
Pin 5,7 Setting password reset to 123456(N.O.)
Pin 6 Reserve

CN2 Relay outputDry contact

Black Brown Red Orange Yellow Green


1 2 3 4 5 6
NO COM NC NO COM NC

Unlock Alarm

CN3 Communication interface


Gray Purple
1 2
TR- TR+

CN4 LED pilot

Red Black Yellow


1 2 3
COM

Assembly drawing