You are on page 1of 1
IS 10987 : 1992 Table 1 Dimensions and Capacities of Horizontal Underground and Above-Ground Storage ‘Tanks With Flat Ends (Clauses 6.2, 9.1, 13-4 and 14:3) Thickness Size of Misimam Minimum Approximate —— Bittfnrs “Wisth” “Breadth 'Ullaze sige Shell Pate (angle of ot ‘Abor Dia Supports Stetions) Sadite Sadale Nominal meter Support Support Capacity See tank tank pete a et, Greate Wee O19 o ® © 0 Gy «Dy Kom oom mmm mm mm mm = mm mm_—_ percent 5 1600 2750 2110 60 $0 5060 GSx6Sx6 ISD 38S 78 75 1600 400 3610 60 50 50 60 6Sx65x6 130138549 10 18004250 3530 GO $0 S080 GSx65x8 2501560059 1S 1950 $500 4720 605.0 $0 BO Ox7xB_ 250168075 2 228 550 460 «806050 BO SOxMxE 25019805 2S 2500 $500 4500 8 ©6060 100 xS0x10 250 2295 68 30 2650 ©6000-4910 80 «G8 100 100x100x10 250 2340 «83 35. 2700 6750-56708 6080100 100x100x10 250 23304 4027507500 640 © 8060-01000 100x100x10 250 2380 95 45-2750 $250 7100 8-0 © GO «8100100 100x10 280 238072 50 2750 9000 7900 80 GOB 100 100x100x10 250 © 238052 55 2750 10000 8900 80 © D8 100 100x100x10 $50 2380 Ot © 2750 1100 9900 80 GDB 100 100x100x10 250 2380 13 7 27501300 1190 806080100 100 100x10 280 2380 84 8 2750 14750 13650 80 60100 10.0 100x100x10 250 2.380 11 $0 2750 16500 15400 80 60100 10.0 100x100x10 2502380 nm NOTES 1 The thickness specified above are the imum roquirement only (including internal and external corrosion allow ance ), pertaining to yield value of steel as 250 MPa 2 The actual thickness required shall be checked taking into the consideration soil pressure, fluid pressure ‘and external loading. 3 End plates in col 8 of the flat ends shall be provided with stffaers given in col 9 and agreed as per Fig. 3E. 4 End plates of the flat ends sha It preferably be without joints. Where the end plate is made by welding of {wojor more plates, the weld Joint shall be made horizontal, Full width of plate(s) should be utilized at the bottom, 10 CORROSION PROTECTION Tanks to be installed underground shall be suitably protected against corrosion caused by the soil strata and/or sub-soil water. The purchaser shall specify type of such protection that the. considers desirable, Suggested. good practices for asphalt doping are given in Annex C. 11 TANK ANCHORAGE 11.1 Tank to be installed underground shall be anchored to resist the buoyancy force induced by high water tables that may oecur seasonally ‘The anchorage could be either provided by means of steel flat of round bars having ade- quate cross section to resist the uplift at a stress level of 140 MPa maximum, 11.2 The anchors should be embedded in RCC draft having necessary dead weight, bonding and shear strength to resist the uplift force. 12 APPURTENANCES AND MOUNTINGS 12.1 General 12.1.1 Appurtenances or mountings installed ‘on tanks shall conform to this code. Alternative designs of appurtenances which provide equiva- lent strength, tightness and utility are. permi sible, if s0 agreed to by the purchaser. 12.1.2 Manhole necks, nozzle necks, reinforcing plates and shell-plate openings which have either sheared or oxygen-cut surfaces, shall have such surface made uniform and smooth, with the corners rounded, ,except where such surfaces are fully covered by attachment welds.

You might also like