REFLECTED CEILING PLAN LEGENDS

WD 01b - WOOD VENEER CLADDING

GB01 -GYPSUM BOARD CEILING PAINTED

GB02 -MOISTURE RESISTANT GYPSUM BOARD PAINTED

GT01 GYPSUM TILE PERFORATED

MC01- SS SHEET CEILING

MC03 -PERFORATED METAL PANEL

MC05 -METAL PANEL

TCT1 -TERRACOTTA TILE (TYPE a)

ST07a

ST21d

GRC

GRG 01
T8.7
METAL HALLIDE (ATRIUM)

T8.6 T8.2 PENDANTLIGHT

T8.5 T8.3 RECESSED DOWNLIGHT

SURFACE MOUNTED DOWNLIGHT

TA RECESSED DOWNLIGHT

METAL HALLIDE

TA DOWNLIGHT IN STRIP

RECESSED SQUARE DOWN LIGHT

LED RECESSED SQUARE DOWN LIGHT

RECESSED MOISTURE PROOF METAL HALIDE


30 SQUARE DOWN LIGHT

600x600 mm FLUORESCENT LIGHT FITTING

COVE LIGHT

TB SMOKE DETECTOR

ANALOGUE INTELLIGENT ADDRESSABLE


SMOKE DETECTOR - BEAM TRANSMITTER

ANALOGUE INTELLIGENT ADDRESSABLE

TB SMOKE DETECTOR - BEAM RECEIVER

LOUD SPEAKER
SERVICE ROAD

BACKGROUND SPEAKER

WALL MOUNTED
SPEAKER

0
CHt 450 SPRINKLER

AR-T8-520
AR-T8-520
MC03

2
SIDE SPRINKLER
CHt 5500 CHt 5500
TC MC01 MC01
AC LINEAR DIFFUSER

AC SUPPLY SPOT DIFFUSER


MC03
0
CHt 450 AC RETURN SPOT DIFFUSER

TC
ST06a ST06a ST06a ST06a
C2
GB01 NOTES:
CHt 5500 - ALL THE JOINTS FOR (ST21d, TCT1, AND ST07a) IN
RCP SHOULD MATCH ELEVATIONS' JOINTS.

ST06a - BACKGROUND SPEAKERS AND LOUD SPEAKERS IN TOWERS'


ST06a LOBBY AT PODIUM LEVEL ARE ALL HIDDEN INSIDE THE S.S RINGS.
ST06a ST06a - BEAM DETECTOR AT ATRIUM SPACE TO BE WALL MOUNTED AT
GB01 LEVEL +14.000 M.
CHt 5500 GB01 - SPRINKLERS SHOULD HAVE SAME COLOR AS CEILING .
- THE SIZE OF HVAC LINEAR DIFFUSERS INSIDE A COVE SHOULD
C2 GB01 BE AS PER HVAC DWG.
ST06a
CHt 5500
- ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
TD ST06a ST06a
ST06a NOTED.
- THE CONTRACTOR SHALL PROVIDE SHOP DRAWING OF RCP
SHOWING ALL CONDITIONS OF INTERFACE BETWEEN DIFFERENT

2 MATERIALS IN CEILING & BETWEEN WALLS & CEILING.

AR-T0-905

CHt 4500

GB01 GB01
MC01
CHt 5000
5
CHt 4500
MC01 TD
CHt 4500 CHt 5000
AR-T8-521 GB01
CHtGB01
4500

AR-T0-905
18

ST07b
00
CHt 45 ST07b
00
C2 ISSUED FOR CONSTRUCTION 02.06.10
CHt 45
C1 ISSUED FOR CONSTRUCTION 31.01.10
00
CHt 45
st07B C0 ISSUED FOR CONSTRUCTION 27.08.09

MC03
CONSTRUCTION DOCUMENT
00
CHt 45

9 BARWA FINANCIAL DISTRICT


AR-T0-902
DOHA, QATAR

GB01
GB01
CHt 4500
BARWA REAL ESTATE (QSC)

0
CHt 450
MC03

T8.7 T8.1
QATAR PROJECT MANAGEMENT
Qatar Project Management

T8.6 T8.2
T8.5 T8.3 P.O. Box 18108, Doha Qatar.

T8.4 1 GROUND LEVEL REFLECTED CEILING (PART PLAN)


C-Ring Road at Al-Mana Intersection
Doha Qatar.
Tel: (974) 4626400, Fax: (974) 4626500
- F.F.L 0.00 Scale 1:100 web: http://www.keoic.com
NORTH email: keo@keoic.com

TOWER-8
GROUND LEVEL
REFLECTED CEILING PLAN
1 : 100 MAY 2010

AP MK
MZ
RS PG

9404 AR-T8-104A C2
A0
Copyright 2007 by KEO International Consultants, WLL