Omnidirectional Antenna 870 960

Vertical Polarization V

VPol Omni 870960 360 11dBi


Type No. 736347
Frequency range 870 960 MHz
Polarization Vertical
Gain 11 dBi
Impedance 50
VSWR < 1.5
Intermodulation IM3 < 150 dBc ( 2 x 43 dBm carrier)
Max. power 500 W (at 50 C ambient temperature)

[119.4 inches]
3033 mm

10
dB

3
Mechanical specifications
0
Input 7-16 female
Subject to alteration.

Vertical Pattern Connector position Bottom


Wind load (N) 210
(at 150 km/h) [lbf] [47]
Max. wind (km/h) 200
velocity [mph] [124]
Height (mm) 3033
[inches] [119.4]
936.1062/i

Radome (mm) 51
diameter [inches] [2.0]
Weight (kg) 8.0
[lb] [17.6]
Packing size (mm) 3316 x 148 x 112
[inches] [130.6 x 5.8 x 4.4]

www.kathrein.com 736347 Page 1 of 2


KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820
Accessories
General Information

Accessories (order separately)


Remarks Weight approx. Units per
Type No. Description
(mm) [inches] (kg) [lb] antenna

738908 2 clamps Mast diameter: 94 125 [3.7 5.0] 2.8 [6.2] 1


737398 Side-mounting Mast diameter: 40 105 [1.6 4.1] 6.4 [14.1] 1
bracket
um
maxim top
Mounting: The antenna can be attached laterally at the tip of a tubular mast of m a s t
5094 mm [2.03.7 inches] diameter with two U-bolt brackets supplied
with the antenna (connecting cable runs outside the mast).

230 [9.1]
Material: Radiator: Copper and brass. Radome: Fiberglass, color: Grey.
Base: Weather-proof aluminum.

150 [6.0]
Mounting kit, screws and nuts: Stainless steel.

Solid, reliable construction: Omnidirectional antennas are often installed at exposed sites on
the top of masts, so special attention has been paid to their mechnical
construction.
The exceptionally stiff fiberglass tube with low tip deflection will withstand
wind velocities of up to 200 km/h [125 mph].
104
Anti-static protection: All metal parts of the antenna as well as the supplied clamp attachment [4.1]
are grounded. The inner conductor is capacitively coupled.

Lightning protection: The antenna is designed to withstand a lightning current of up to


150 KA (impulse: 10/350 s), according to IEC 62305 parts 14 and
VDE 0855-300, and thereby fulfils the requirements of lightning protection
Dimensions in mm and [inches]
class II. Grounding cross-section: 22 mm2 copper.

Subject to alteration.
936.1062/i

Page 2 of 2 736347 Any previous data sheet issues have now become invalid.
www.kathrein.com
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820
General Information
about Panel Antennas

Environmental Kathrein cellular antennas are designed to operate under the environmental conditions
conditions: as described in ETS300019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
Low temperature: 55 C
High temperature (dry): +60 C
For antennas equipped with FlexRET: The electrical downtilt adjusting is designed to
operate under the environmental conditions as described in the valid data sheet of the
FlexRET.

Ice protection: Due to the very sturdy antenna construction and the protection of
the radiating system by the radome, the antenna remains operational even under icy
conditions.

Environmental Kathrein antennas fulfil the stated specifications after completion of the environmental
tests: tests as defined in ETS300019-2-4. The homogenous d esign of Kathreins antenna
families uses identical modules and materials.
Extensive tests have been performed on typical samples and modules. The vibration
test has been adapted relating to frequency and acceleration to the conditions of mast
mounted antennas.

Please note: As a result of more stringent legal regulations and judgements regarding product
liability, we are obliged to point out certain risks that may arise when products are
used under extraordinary operating conditions.

The mechanical design is based on the environmental conditions as stipulated in


ETS300019-1-4. Wind loads are calculated according to DIN1055-4.
The antennas may be used at locations where the anticipated peak wind velocity or
gust wind speed lies within the maximum wind speed listed in the data sheet. We
warrant the mechanical safety and electrical functionality under such conditions.

The wind speeds are defined in accordance with the DIN, EN or TIA standards. This
warranty makes allowance for the partial safety factors specified in those standards.
Extraordinary operating conditions, such as heavy icing or exceptional d ynamic stress
(e.g. strain caused by oscillating support structures), may result in the b
reakage of an
antenna or even cause it to fall to the ground. These facts must be c onsidered during
the site planning process.

The details given in our data sheets have to be f ollowed carefully when installing
the antennas and a ccessories.
Site planning and installation must be carried out by qualified and experienced
staff. All relevant national safety regulations must be upheld and respected.
Incorrect site planning, faulty installation, as well as interfering surroundings
on site, may lead to deviations in the electrical parameters compared to those
specified in the respective data sheets.
The connectors on this product are only suitable for connecting to the compatible
counterpart. Please ensure that the connected cable has been fitted with a
connector of the same standard, otherwise damage may occur.

The tilt values will be set to any arbitrary value in the given tilt range. These values
Subject to alteration.

are independent from the frequency band or antenna type and can vary between
antennas and bands.

EU-RED Hereby, Kathrein Werke KG declares that the radio equipment is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at
the following internet address: http://www.kathrein.com
936.4694/d

Our quality assurance system and our RoHS Our products are compliant to the
environmental management system apply EU Directive RoHS as well as to other
to the entire company and are certified environmentally relevant regulations
by TV according to EN ISO 9001 and (e.g. REACH).
ENISO 14001.