You are on page 1of 2

Service Setup Department

Technical Information
Title of Info New Jumper Setting for Head-Board-Modular
Ref. No.: 10E02022 Author: Klaus Grahammer

Referring to: Contact person: TSC Hotline Munich

Keyword 1: gantry Telefon: +49 (0)89 722 48642

Keyword 2: conversion board small axis Distributor: Online Infopool


Keyword 3: Cc:

Service strategy: No service strategie


Setup strategy: No system acceptance strategie

Short description: New Jumper Setting for Head-Board-Modular

Handling of this document:


- for service:
- for setup:

1HZ-XPSHU6HWWLQJIRU+HDG%RDUG0RGXODU

Standard OFF OFF OFF OFF ON ON CAN_Adresse:

Switch setting 1 2 3 4 5 6 7 8
CAN_R120 EPROM_WE Test_Mode CAN_ERR_SWITCH Jumper 5 Jumper 6 CAN_ID1 CAN_ID0
21 ; ;
2)) ; ; ; ;

The wiring of the switch depends on the placement machine involved:

Jumper 1: ON CAN terminating impedance on placement head is set (S20, S23, S25, F4, F5 and
F5HM)
OFF CAN terminating impedance is not wired on the head (HS50 default)

Jumper 2: ON Set during download


OFF Default status

Jumper 3: ON Test mode


OFF Default status

Jumper 4: ON Test mode (setting of CAN ID)


OFF Default status
PL EA 1 Technische nderungen vorbehalten / Subject to change without prior notice 05.02.02
Rupert-Mayer-Str. 44 Page/Seite 1 / 2
D-81359 Mnchen 10E02022.doc
Jumper 5: ON Default status

Jumper 6: ON Default status

Jumper 7,8: CAN_ID:

Gantries: Jumper 7 Jumper 8

Portal 1 ON ON

Portal 2 ON OFF

Portal 3 OFF ON

Portal 4 OFF OFF

PL EA 1 Technische nderungen vorbehalten / Subject to change without prior notice 05.02.02


Rupert-Mayer-Str. 44 Page/Seite 2 / 2
D-81359 Mnchen 10E02022.doc

You might also like